Telecopy AO BFAO-7348T:on 731225,during Routine Surveillance Testing,Hpci Turbine Failed to Reach Rated Speed & Flow. Cause Appears to Be in Turbine Hydraulic Control Sys
ML20085M346
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 12/26/1973
From: Green H
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20085M343 List:
References
AO-BFAO-7348T, NUDOCS 8311080270
Download: ML20085M346 (1)


Text

.

301P EST DEC 26 73 AC115 DUPLICATE OF TELEPHONED TELEGRAM A AB 136( 1443 )(2-0 93611 E360 )PD 12/26/73 1440 IC S IPMMTZZ CSP 6092342900 TDMT MOORESTOWN NJ 12-26 0240P EST PMS 2-089548E360 2057298316 TD8 N ATHEN S AL 49 12-26 0222P EST US ATOM IC ENERGY COMMISSIO N, WUX D IRECTDRETTE O F RES ULATORY OPER ATIO N S 230 PEACHTREE ST FORTH'4EST ATLANTA G A 30303 SWJECT B FAO 7348T DURING ROUTINE SURVEILLANCE TESTING OF THE HPC I SY STEM S 0 N D ECEMB ER 25 1973 THE HPCI TURB INE FAILED 10 REACH RATED SPEED AND FLOW THE REACTOR WAS OPERATING AT 1583 M4T W ITH 443 M'4E O UTPUI PREL IM IN ARY INVESTIG ATION INDICATE THE ,

TROWLE TO BE IN THE TURB INE HYDRhkJLIC C0 NTROL SYSTEM H J GREEN BROVN SPERRY NLCLEAR PLANT NNNN n ,

!) yp &f $~

jg$p, $

~

AF-1201 (RS 49) y 1  :

7 1

5 i k '

1 I

e311080270 740104 i PDR ADOCK 05000 ,