05000296/LER-1999-004-02, :on 990625,facility Core Spray Divisions I & II Inoperable at Same Time Due to Personnel Error.Electrical Supply Breaker to Core Spray Division II Pump 3B Returned to Normal Racked in Position

From kanterella
(Redirected from ML18039A820)
Jump to navigation Jump to search
:on 990625,facility Core Spray Divisions I & II Inoperable at Same Time Due to Personnel Error.Electrical Supply Breaker to Core Spray Division II Pump 3B Returned to Normal Racked in Position
ML18039A820
Person / Time
Site: Browns Ferry 
Issue date: 07/26/1999
From: Donald Norwood
TENNESSEE VALLEY AUTHORITY
To:
Shared Package
ML18039A819 List:
References
LER-99-004-02, NUDOCS 9908030241
Download: ML18039A820 (12)


LER-1999-004, on 990625,facility Core Spray Divisions I & II Inoperable at Same Time Due to Personnel Error.Electrical Supply Breaker to Core Spray Division II Pump 3B Returned to Normal Racked in Position
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(ii)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(iv), System Actuation

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications
2961999004R02 - NRC Website

text

NRC FORM 366 (6-)99BI U.S..NUCLEAR REGULATORY COMMISSION (See reverse for required number of digits/characters for each block) llCENSEE EVENT REPORT (I.ER)

APPROVED BY OMB NO. 3160-0104 EKP)RES os)so)soot the NRC may not conduct or sponsor, and a person d not requ)red to respond to. the hformaUon~

FAClUTYNAMEIS)

Browns Ferry Nuclear Plant - Unit 3 DOCKET NUMSER (2) 05000296 PAOE IS) 1 of 6 TrTLEla)

Inoperability of Two Divisions of the Unit 3 Core Spray System Due to Personnel Error EVENT DATE (5I LER NUMBER (6)

REPORT DATE (7)

OTHER FACILITIES INVOLVED(6)

MONTH DAY YEAR YEAR sEOUENT)AL REv)S)ON NUMBER NUMBER MONTH DAY YEAR FACIUTYNAME NA DOCKET NUMBER NA 06 25 1999 1999

- 004-00'7 26 999 NA DOCKET NUMBER NA OPERATING MODE le)

POWER I.EVEL (10) 100 X 50.73(a)(2)(i) 20.2203(a)(2)(v) 20.2201(b)

So 73(a) (2) (vln

)

S0.73(a)(2)(x) 73.71 OTHER 50.73(a) (2) (ii) 50.73(a)(2)(iii) 50.73(a)(2)(iv) 20.2203(a)(3)(i) 20.2203 la)(3)(ii) 20.2203(a)(4)

20. 2203(a) (1) 20.2203la) l2)II) 20.2203(a) (2)(ii)

THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR Ii: (Check one or moro) (11) 20.2203(a) (2)(iii)

20. 2203(al(2) (iv) 50.36(c)(1).

50.36(c)(2) 50.73(a)(2)(v) 50.73(a)(2) (vil)

Spec)fy In Abstract below or in NRC Form 366A Donald Norwood, Sr. Project Manager LICENSEE CONTACT FOR THIS LER (12)

TELEPHONE NUMBER (Inorudo Area Coda)

(256) 729-7905 COMPLETE ONE LINE FOR EACH COMPONENT FAILURE DESCRIBED IN THIS REPORT (13)

SYSTEM COMPONENT MANUFACTURER REPORTABLE TO NPRDS gj'$$ ;a

'A%?ii..";"i:

CAUSE

COMPONENT, MANUFACTURER REPORTABLE TO NPRDS SUPPLEMENTAL REPORT EXPECTED (14)

YES (If yes, complete EXPECTED SUBMiSSION DATE).

X NO EXPECTED SUBMISSION DATE (15)

MONTH 0AY YEAR ABSTRACT (Umit to 1400 spaces, I.e., approximately 15 single-spaced typewritten lines) (16)

On June 25, 1999, at 1352 hours0.0156 days <br />0.376 hours <br />0.00224 weeks <br />5.14436e-4 months <br /> Central Daylight Time (CDT), Unit 3 Core Spray (CSI Divisions I and II were technically inoperable at the same time. This condition was the result of personnel error during performance of the surveillance test, Backup Control Panel Testing (3-SR-3.3.3.2.1(75 I)]for CS Division I. During performance of the surveillance test, the electrical supply breaker for CS Division II pump 3B was racked out instead of the breaker for CS Division I pump 3C as required by the surveillance test. Prior to the event, CS Division I pump 3A had been made inoperable per the surveillance test. This action had made CS Division I inoperable.

At the time of the event, pump 3A had been returned to a condition where it was available (and hence CS Division I was available), and would have functioned ifrequired.

However, CS Division I was still inoperable per plant Technical Specifications.

The operations'taff recognized that two divisions of CS were inoperable and appropriately entered LCO 3.0.3. At 1418 hours0.0164 days <br />0.394 hours <br />0.00234 weeks <br />5.39549e-4 months <br /> CDT, CS Division IIwas returned.to operable status and LCO 3.0.3 exited. The root cause of this event was personne) error.

Prior to, and during the event, all other Emergency Core Cooling Systems (ECCS) were operable. Accordingly, there was no significant reduction in the degree of protection provided to the public health and safety.

Furthermore, the safety of the plant, its personnel, and the public was not compromised.

This report is submitted pursuant to 10 CFR 50.73 (a)(2)(i)(B), as any operation or condition prohibited by the plant's Technical Specifications.

'))'))080302@i 990726 PDR tf))DOCK 0500029b 8

PDR

41 IIS-I998i L[CENSEE EVENT REPORT (LER)

TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME 1

Browns Ferry Nuclear Plant - Unit 3 DOCKET 05000296 LER NUMBER 6 YEAR SEOUENTIAL REVISION NUMBER 1999 004

00 PAGE 3 2of6 TEXT fifmore spaceis required, use additional copies of NRC Form 366A/ (17)

PLANTCONDITION{S)

At the time of the event, Unit 1 was shutdown and defueled.:Unit 2 was in Mode 1 at 100 percent reactor power, approximately 3456 megawatts thermal.

Unit 3 was in mode 1 at 100 percent reactor power, approximately 3456 megawatts thermal.

DESCRIPTION OF EVENT

A. Event:

On June 25, 1999 at 1145 hours0.0133 days <br />0.318 hours <br />0.00189 weeks <br />4.356725e-4 months <br /> Central Daylight Time (CD7) surveillance test Backup Control Panel Testing [3-SR-3.3.3.2.1(75 I)] for Core Spray (CS) [BM]Division I was started.

At 1230 hours0.0142 days <br />0.342 hours <br />0.00203 weeks <br />4.68015e-4 months <br /> CDT, CS pump 3A [P] was made inoperable per the surveillance test by racking out its electrical supply breaker [BKR]. This action made CS Division I inoperable.

At 1349 hours0.0156 days <br />0.375 hours <br />0.00223 weeks <br />5.132945e-4 months <br /> CDT, the electrical supply breaker for CS pump 3A was returned to its normal racked in position.

At 1351 hours0.0156 days <br />0.375 hours <br />0.00223 weeks <br />5.140555e-4 months <br /> CDT, CS pump 3A was declared available but stilt not operable per Technical Specifications.

3-SR-3.3.3.2.1(75 I) then required racking out the electrical supply breaker [BKR]for CS Division I pump 3C [P]. However, at 1352 hours0.0156 days <br />0.376 hours <br />0.00224 weeks <br />5.14436e-4 months <br /> CDT, the Assistant Unit Operator {AUO)[utility, non-licensed] performing the breaker manipulations racked out the electrical supply breaker [BKR]for CS Division II pump 3B [P] instead.

This action resulted in CS Division II being inoperable.

In conjunction with the technically inoperable CS Division I, this resulted fn a condition prohibited by the plant's Technical Specifications.

Limiting Condition for Operation (LCO) 3.0.3 was entered at that time.

The electrical supply breaker to the CS Division II pump 3B was returned to its normal racked in position. CS Division II was tested for operability per 3-OI-75. CS Division II was declared operable at 1418 hours0.0164 days <br />0.394 hours <br />0.00234 weeks <br />5.39549e-4 months <br /> CDT and LCO 3.0.3 was exited at that time.

B. Ino erable Structures Com onents orS stemsthatContributedtothe Event:

None.

C.

Dates and A roximate Times of Ma or Occurrences:

June 25, 1999, 1145 hours0.0133 days <br />0.318 hours <br />0.00189 weeks <br />4.356725e-4 months <br /> CDT Surveillance 3-SR-3.3;3.2.1{75 I), Backup Control Panel Testing for Core Spray Division I was started.

June 25, 1999, 1230 hours0.0142 days <br />0.342 hours <br />0.00203 weeks <br />4.68015e-4 months <br /> CDT Breaker for Core Spray Division I pump 3A racked out per Surveillance 3-SR-3.3.3.2.1{75 I); Core Spray pump 3A, and hence Core Spray system Division I, declared inoperable.

Ik 41(6-1998)

LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME 1

Browns Ferry Nuclear Plant - Unit 3 DocKET 05000296 LER NUMBER 6 YEAR SEQUENTIAL REVISION NUMBER 1999 004

00 PAGE 3 3 of 6 TEXT (i!more space is required, use additional copies of NRC Form 366Ai I17)

June 25, 1999, 1349 hours0.0156 days <br />0.375 hours <br />0.00223 weeks <br />5.132945e-4 months <br /> CDT Breaker for Core Spray Division I pump 3A returned to the normal racked in position.

June 25, 1999, 1351 hours0.0156 days <br />0.375 hours <br />0.00223 weeks <br />5.140555e-4 months <br /> CDT Core Spray pump 3A, and hence Core Spray Division I available for.service per maintenance rule.

June 25, 1999, 1352 hours0.0156 days <br />0.376 hours <br />0.00224 weeks <br />5.14436e-4 months <br /> CDT June 25, 1999, -1400 hours CDT Breaker for Core Spray Division II pump 3B racked out. Surveillance 3-SR-3.3.3.2.1(75 I) specified breaker for Core Spray Division I pump 3C to be racked out. This action caused Division II ofthe Core Spray system to be inoperable.

With both Divisions of the Core Spray system inoperable, LCO 3.0.3 was entered.

Unit 3 SRO directed that Core Spray Division II pumps be run per Operating Instruction (Ol) 75 to allow Core Spray Division II to be declared operable.

June 25, 1999, 1416 hours0.0164 days <br />0.393 hours <br />0.00234 weeks <br />5.38788e-4 months <br /> CDT Core Spray Division II pumps 3B and 3D placed in service per 3-OI-75, Section 8.12.

June 25, 1999, 1418 hours0.0164 days <br />0.394 hours <br />0.00234 weeks <br />5.39549e-4 months <br /> CDT Core Spray Division II pumps 3B and 3D secured.

Core Spray Division II declared operable.

LCO 3.0.3 exited.

D. Other S stems or Seconda Functions Affected None.

E.

Method of Discove During performance of Surveillance 3-SR-3.3.3.2.1(75 I), Unit 3 Control Room Operators [utility, licensed] noticed that expected annunciators for CS Division I pump 3C had not alarmed, but annunciators for CS Division II pump 3B that were not expected to be in alarm status had in fact alarmed.

F.

0 erator Actions NRC FORM 366 {6-199B)

At 1352 hours0.0156 days <br />0.376 hours <br />0.00224 weeks <br />5.14436e-4 months <br /> CDT, the Assistant Unit Operator (AUO) [utility,non-licensed] performing the breaker manipulations racked out the electrical supply breaker for CS Division II pump 3B instead of the breaker required by the surveillance (CS Division I pump 3C breaker).

This was a cognitive error in that the AUO had mentally incorrectly associated CS pump 3B with Division I instead of CS pump 3C. This error was contrary to the approved surveillance.

There were no unusual characteristics of the work location (e.g., heat, noise) that directly contributed to this error.

0 4I6-1998)

LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME 1

Browns Ferry Nuclear Plant - Unit 3 DOCKET 05000296 LER NUMBER 6 YEAR SEQUENTIAL NUMBER 1999 004

00 PAGE 3 4 of6 TEXT llfmore spaceis required, use additional copies of ftiRCForm 366A/ f17I G. Safet S stem Res onses None.

III.

CAUSE OF THE EVENT

A. Immediate Cause The immediate cause of this event was the racking out of the incorrect CS pump electrical supply breaker (CS pump 3B breaker instead of CS pump 3C breaker).

B, Root Cause The root cause of the event was personnel error. The wrong Core Spray pump breaker was removed due to a lack of effective self-checking with no peer check performed.

C. Contributin Factors The two 4 KVelectrical board rooms on Unit 3 have both Division I and Division II boards in the same room (Shutdown (S/D) Boards [ECBD] 3A and 3C in one, S/D boards 3B and 3D ln the other). The boards in each room are separated by an automatically closing fire door within the.

same room. The lack of visual separation of these rooms contributed to the mind-set that boards 3A and 3C were in the same division.

The 3B Emergency Core Cooling System (ECCS) pumps are on 3C 4 KVS/D board (Division II) and 3C pumps are on 38 4KVS/D board (Division I).

The pre-job brief was inadequate forthe evolution.

Failure of management observations to detect problems with effective self-checking.

IV.

ANALYSISOF THE EVENT Prior to performance of the surveillance test, a pre-job brief was performed.

However, no formal prejob briefing package was written. Specific steps of the procedure were not pointed out, including no reference made to the fact that the Unit 3 S/D Board rooms have two divisions in each room.

This coupled with the fact that CS pump 3B is fed from. the 3C 4KVS/D Board and CS pump 3C is fed from the 3B 4KV S/D board led to an incorrect association of CS pumps to their divisional assignments by the individual performing the operator actions in the surveillance test. This incorrect association.was that the CS pumps 3A and 3B were Division I pumps instead of the correct CS pumps 3A and 3C.

V.

ASSESSMENT OF THE SAFETY CONSEQUENCES The purpose of the Core Spray system is to protect against over-heating the fuel in the event. of a Loss of Coolant Accident (LOCA). There are two independent, redundant, 100% capacity Core S ra Divisions Division I and Division ll. CoreS ra in con'unction with other ECCS Automatic NRC FORM 366 I6-1998)

0

NRO FDRM 3eeA (6-1998I LICENSEE EVENT REPORT (LER)

TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME 1 Browns Ferry Nuclear Plant - Unit 3 DOCKET 05000296 LER NUMSER 6 YEAR SEQUENTIAl REVISION NUMBER 1999 004

00 PAGE 3 TEXT (Iimore space is required, use additional copies ol iVRC Farm 366AJ 117)

'V.Depressurization System (ADS) [SB], Low Pressure Coolant Injection (LPCI) [BO], and High Pressure Coolant Injection (HPCI) [BJ]) provide adequate core cooling over the entire LOCA break spectrum.

At the time of this event, CS Division I was inoperable per Technical Specifications.

However, CS Division I was in a condition where it was available had It been called upon to function. CS Division II was made Inoperable for only a short period oftime (minutes) prior to it being recognized that the wrong electrical supply breaker had been racked out. Upon recognizing this, the electrical supply breaker to CS Division II pump 38 was returned to the normal racked in position. At this time, CS Division II was then available had it been called upon to function. Within 26 minutes after the wrong electrical supply breaker was racked out, CS Division II was tested and declared operational per Technical Specifications.

Prior to, and throughout this short duration event, all other ECCS remained operable.

Accordingly, there was no significant reduction in the degree of protection provided to the public health and safety.

Furthermore, the safety of the plant, its personnel, and the public was not compromised.

VI.

CORRECTIVE ACTIONS

A. Immediate Corrective Actions The electrical supply breaker to CS Division II pump 38 was returned to its normal racked in position. The Unit 3 SRO directed that CS Division II pumps be placed in service to demonstrate operability. CS Division II successfully demonstrated operability and at 141 &'hours CDT CS Division II was declared operable.

B. Corrective Actions to Prevent Recurrence Future pre-job briefings willinclude warnings about this specific human factors issue.

The Operations'raining Department willinclude this event in the "Plant Events simulator scenario training for Licensed operator requalification training and in the required reading program of non-licensed personnel.'perations'anagement willestablish a self-assessment that mill focus on management observations to detect problems with effective self-checking.

'eer checks on actions associated with breaker operations, placement ofjumpers, pulling fuses, or other actions which cause irreversible conditions on equipment willbe required for surveillances and other critical tests.

'pplicable initial licensed and non-iicensed operator training lesson plans will be revised to include issues associated with this event.'VA does not consider these corrective actions regulatory commitments.

The completion of these items will be tracked in TVA's Corrective Action Pro ram.

NRc FoRM See 18-19981

0 PI6 1998)

LICENSEE EVENT'REPORT. (LER)

TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION'ACILITY NAME 1 Browns Ferry Nuclear Plant - Unit.3 DOCKET 05000296 LER NUMBER 6 YEAR SEQUENTIAL REVISION NUMBER 1999 004

00 PAGE 3 col 6 TEXT (Ifmore space is required, use additional copies of iVRCForm 366AJ I17I VII.

ADDITIONALINFORMATION.

A. Failed Com onents None.

B.

Previous LERs on Similar Events LER 50-296/97004, issued on May'14, 1997,,was written to document the unplanned manual start of Emergency Diesel Generator (EDG) 3D as a result of personnel error during surveillance testing;

C. Additional Information

None D.

Safe S stem Functional Failure:

This event did not result in a safety system functional failure in accordance with NEI 99-02.

VIII.

COMMITMENTS

None.

NRC FORM 366 (6-1998I

~I