ML040130278

From kanterella
Revision as of 21:15, 19 March 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Letter, Correction Letter for Amendments 164/150
ML040130278
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 01/14/2004
From: Macon W
NRC/NRR/DLPM/LPD3
To: Skolds J
Exelon Generation Co
Macon W, NRR/DLPM,415-3965
References
TAC MB9888, TAC MB9889
Download: ML040130278 (4)


Text

January 14, 2004 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

LASALLE COUNTY STATION, UNITS 1 AND 2 - CORRECTION TO ISSUANCE OF AMENDMENTS (TAC NOS. MB9888 AND MB9889)

Dear Mr. Skolds:

On January 9, 2004, the Nuclear Regulatory Commission (Commission) issued Amendment No. 164 to Facility Operating License No. NPF-11 and Amendment No. 150 to Facility Operating License No. NPF-18 for the LaSalle County Station, Units 1 and 2, (LaSalle) respectively. The amendments consisted of changes to the Technical Specifications (TS) in response to your application dated July 1, 2003, as supplemented by letter dated December 10, 2003.

Based on discussions between your staff and the Commission staff on January 12, 2004, we are reissuing a corrected copy of page 5 of the Safety Evaluation dated January 9, 2004. The lower end of the Inlet Sub-Cooling range and the lower end of the R-Factor were incorrectly listed as 0.1 Btu/lbm and 1.03, respectively. These values should be 6 and 1.02, consistent with your supplemental letter dated December 10, 2003. The third paragraph is also corrected to reference the use of additional data provided in the December 10 letter to support these values rather than the use of extrapolated data.

We apologize for any inconvenience this may have caused.

Sincerely,

/RA/

William A. Macon, Jr., Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-373 and 50-374

Enclosure:

As stated cc w/encl: See next page

January 14, 2004 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

LASALLE COUNTY STATION, UNITS 1 AND 2 - CORRECTION TO ISSUANCE OF AMENDMENTS (TAC NOS. MB9888 AND MB9889)

On January 9, 2004, the Nuclear Regulatory Commission (Commission) issued Amendment No. 164 to Facility Operating License No. NPF-11 and Amendment No. 150 to Facility Operating License No. NPF-18 for the LaSalle County Station, Units 1 and 2, (LaSalle) respectively. The amendments consisted of changes to the Technical Specifications (TS) in response to your application dated July 1, 2003, as supplemented by letter dated December 10, 2003.

Based on discussions between your staff and the Commission staff on January 12, 2004, we are reissuing a corrected copy of page 5 of the Safety Evaluation dated January 9, 2004. The lower end of the Inlet Sub-Cooling range and the lower end of the R-Factor were incorrectly listed as 0.1 Btu/lbm and 1.03, respectively. These values should be 6 and 1.02, consistent with your supplemental letter dated December 10, 2003. The third paragraph is also corrected to reference the use of additional data provided in the December 10 letter to support these values rather than the use of extrapolated data.

We apologize for any inconvenience this may have caused.

Sincerely,

/RA/

William A. Macon, Jr., Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-373 and 50-374

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION:

PUBLIC PD3-2 r/f OGC GHill (4)

WBeckner ACRS DHills, RIII FAkstulewicz AAttard EKendrick ADAMS Accession Number: ML040130278 OFFICE PM:LPD3-2 LA:LPD3-2 SC:SRXB-A SC:LPD3-2 NAME WMacon PCoates FAkstulewicz AMendiola DATE 1/13/04 1/13/04 1/13/04 1/14/04 OFFICIAL RECORD COPY

LaSalle County Station Units 1 and 2 cc:

Site Vice President - LaSalle County Station Robert Cushing, Chief, Public Utilities Division Exelon Generation Company, LLC Illinois Attorney Generals Office 2601 North 21st Road 100 W. Randolph Street Marseilles, IL 61341-9757 Chicago, IL 60601 LaSalle County Station Plant Manager Regional Administrator Exelon Generation Company, LLC U.S. NRC, Region III 2601 North 21st Road 801 Warrenville Road Marseilles, IL 61341-9757 Lisle, IL 60532-4351 Regulatory Assurance Manager - LaSalle Illinois Emergency Management Exelon Generation Company, LLC Agency 2601 North 21st Road Division of Disaster Assistance &

Marseilles, IL 61341-9757 Preparedness 110 East Adams Street U.S. Nuclear Regulatory Commission Springfield, IL 62701-1109 LaSalle Resident Inspectors Office 2605 North 21st Road Document Control Desk - Licensing Marseilles, IL 61341-9756 Exelon Generation Company, LLC 4300 Winfield Road Phillip P. Steptoe, Esquire Warrenville, IL 60555 Sidley and Austin One First National Plaza Senior Vice President - Nuclear Services Chicago, IL 60603 Exelon Generation Company, LLC 4300 Winfield Road Assistant Attorney General Warrenville, IL 60555 100 W. Randolph St. Suite 12 Chicago, IL 60601 Vice President - Operations Support Exelon Generation Company, LLC Chairman 4300 Winfield Road LaSalle County Board Warrenville, IL 60555 707 Etna Road Ottawa, IL 61350 Chief Operating Officer Exelon Generation Company, LLC Attorney General 4300 Winfield Road 500 S. Second Street Warrenville, IL 60555 Springfield, IL 62701 Vice President - Licensing and Regulatory Chairman Affairs Illinois Commerce Commission Exelon Generation Company, LLC 527 E. Capitol Avenue, Leland Building 4300 Winfield Road Springfield, IL 62706 Warrenville, IL 60555

LaSalle County Station Units 1 and 2 Director Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Counsel, Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Clinton and LaSalle Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

(d) A final set of additive constants are determined by adjusting the preliminary additive constants, subject to minimizing the difference between the R-Factors.

The range of application for the GEXL97 correlation is the same as the range of the hypothetical database from which the correlation is derived. The applicable ranges are presented below:

i) Pressure: 800 to 1300 psia ii) Mass Flux: 0.1x106 to 1.5x106 lb/hr-ft2 iii) Inlet Sub-cooling: 6 to 100 Btu/lbm iv) R-Factor: 1.02 -- 1.20 This application range covers the complete range of expected operation of the ATRIUM-10 fuel during normal steady state and transient conditions in the LSCS BWR reload cores.

The lower end of the Inlet Sub-cooling range differs slightly from that presented in the licensees original submittal dated July 1, 2003. In that document, the lower end of the range was extrapolated from 10 down to zero for the Inlet Sub-cooling and the R-Factor range was also extrapolated from 1.03 down to 1.02. Following discussions with the NRC staff (documented in Ref. 2), the licensee and GNF acquired additional subcooling and R-Factor data to justify the desired ranges within the limits of the development database of the GEXL97 correlation.

With respect to the ranges stated above, GNF provided the results of analysis of the reference loading pattern for the LaSalle Unit 1, Cycle 11 mixed core reload, which has core operating characteristics that are representative of the conditions that will be encountered during this cycle. The CPR was extracted for all the ATRIUM-10 fuel throughout the entire cycle.

In summary, the NRC staff reviewed the analyses and results presented in NEDC-33106P, "GEXL97 Correlation for ATRIUM-10 Fuel," and determined that the analyses and results are in accordance with the guidance and limitations of 10 CFR 50.34, and the applicable sections of NUREG-0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants." In addition, the staff concludes that the analysis presented in NEDC-33106P is acceptable because:

(a) The total uncertainty in the correlations critical power predictions appropriately takes into account the fact that the uncertainty in the new correlations fit to the hypothetical database and the uncertainty in the hypothetical database with respect to the underlying experimental data are appropriately treated; (b) Generating the hypothetical database using the approved SPCB correlation encoded in the Framatome subchannel code XCOBRA-T is a reasonable engineering approach to dealing with mixed reload core fuel, where the experimental database and critical power correlation for the previous vendors fuel is not available to the new fuel vendor; (c) GNF intends to utilize the new GEXL97 correlation within the limits of the hypothetical data base, without extrapolation outside the approved limits of the data base, as specified in this safety evaluation (SE); and