ML033100237
| ML033100237 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 11/10/2003 |
| From: | Macon W NRC/NRR/DLPM/LPD3 |
| To: | Skolds J Exelon Generation Co, Exelon Nuclear |
| Macon W, NRR/DLPM,415-3965 | |
| References | |
| TAC MB9888, TAC MB9889 | |
| Download: ML033100237 (5) | |
Text
PROPRIETARY INFORMATION November 10, 2003 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
LASALLE COUNTY STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION RE: CORE OPERATING LIMITS REPORT (TAC NOS. MB9888 AND MB9889)
Dear Mr. Skolds:
By letter dated July 1, 2003, you submitted a request for amendment to Technical Specifications (TS) related to TS Section 5.6.5, "Core Operating Limits Report." This submittal contained Global Nuclear Fuel proprietary report NEDC-33106P, "GEXL97 Correlation for ATRIUM-10 Fuel," Revision 1, dated June 2003. The U.S. Nuclear Regulatory Commission (NRC) staff has performed an initial review of your request for NRC approval of this report and finds that it needs additional information to complete its review.
Therefore, it is requested that you respond to the enclosed request for additional information by November 28, 2003, for the NRC staff to expedite its review. The response date was agreed upon by members of your staff via telephone conference on October 30, 2003. The enclosed questions are unchanged from those sent by e-mail to a member of your staff on October 20, 2003.
Sincerely,
/RA/
William A. Macon, Jr., Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-373 and 50-374
Enclosure:
As stated cc w/o encls: See next page Document transmitted herewith contains sensitive unclassified information. When separated from enclosure, this document is decontrolled.
PROPRIETARY INFORMATION
LaSalle County Station Units 1 and 2 cc:
Site Vice President - LaSalle County Station Exelon Generation Company, LLC 2601 North 21st Road Marseilles, IL 61341-9757 LaSalle County Station Plant Manager Exelon Generation Company, LLC 2601 North 21st Road Marseilles, IL 61341-9757 Regulatory Assurance Manager - LaSalle Exelon Generation Company, LLC 2601 North 21st Road Marseilles, IL 61341-9757 U.S. Nuclear Regulatory Commission LaSalle Resident Inspectors Office 2605 North 21st Road Marseilles, IL 61341-9756 Phillip P. Steptoe, Esquire Sidley and Austin One First National Plaza Chicago, IL 60603 Assistant Attorney General 100 W. Randolph St. Suite 12 Chicago, IL 60601 Chairman LaSalle County Board 707 Etna Road Ottawa, IL 61350 Attorney General 500 S. Second Street Springfield, IL 62701 Chairman Illinois Commerce Commission 527 E. Capitol Avenue, Leland Building Springfield, IL 62706 Robert Cushing, Chief, Public Utilities Division Illinois Attorney General's Office 100 W. Randolph Street Chicago, IL 60601 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, IL 60532-4351 Illinois Emergency Management Agency Division of Disaster Assistance &
Preparedness 110 East Adams Street Springfield, IL 62701-1109 Document Control Desk - Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Operations Support Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Chief Operating Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
LaSalle County Station Units 1 and 2 Director Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Counsel, Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Clinton and LaSalle Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
PROPRIETARY INFORMATION November 10, 2003 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
LASALLE COUNTY STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION RE: CORE OPERATING LIMITS REPORT (TAC NOS. MB9888 AND MB9889)
Dear Mr. Skolds:
By letter dated July 1, 2003, you submitted a request for amendment to Technical Specifications (TS) related to TS Section 5.6.5, "Core Operating Limits Report." This submittal contained Global Nuclear Fuel proprietary report NEDC-33106P, "GEXL97 Correlation for ATRIUM-10 Fuel," Revision 1, dated June 2003. The U.S. Nuclear Regulatory Commission (NRC) staff has performed an initial review of your request for NRC approval of this report and finds that it needs additional information to complete its review.
Therefore, it is requested that you respond to the enclosed request for additional information by November 28, 2003, for the NRC staff to expedite its review. The response date was agreed upon by members of your staff via telephone conference on October 30, 2003. The enclosed questions are unchanged from those sent by e-mail to a member of your staff on October 20, 2003.
Sincerely,
/RA/
William A. Macon, Jr., Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-373 and 50-374
Enclosure: