Final Status Survey Final Report Phase IV, Appendix A2, Survey Unit Release Record 9106-0002, Discharge Canal
ML063400431
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/06/2006
From: Newson C
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9106-0002
Download: ML063400431 (273)


Text

Book of 1 Final Status Survey Final Report Phase IV Appendix A2 Survey Unit Release Record 9106-0002, Discharge Canal November 2006

CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0002 Prepared By: Date: //- -Od FSS Engineer Reviewed By: Date:

Egineer Approved By: Date:__

Technical Support Manager Revision 0

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD TABLE OF CONTENTS

1. SURVEY UNIT DESCRIPTION ................................................................ 3
2. CLASSIFICATION BASIS ....................................................................... 3
3. DATA QUALITY OBJECTIVES (DQO) ................................................... 5
4. SURVEY DESIG N ................................................................................... 9
5. SURVEY IMPLEMENTATION ................................................................ 12
6. SURVEY RESULTS ............................................................................... 13
7. QUALITY CONTROL ............................................................................. 14
8. INVESTIGATIONS AND RESULTS ....................................................... 15
9. REMEDIATION AND RESULTS ............................................................ 15
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ..................... 15
11. DATA QUALITY ASSESSMENT (DQA) ............................................... 15
12. A NO M A LIES .......................................................................................... 16
13. CO NC LUSIO N ........................................................................................ 16
14. ATTACHMENTS .................................................................................... 17 14.1 Attachment 1 - Figures (5 pages including cover) 14.2 Attachment 2 - Sample and Statistical Data (249 pages including covers)

Revision 0

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD

1. SURVEY UNIT DESCRIPTION Survey Unit 9106-0002 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 5520 m2 ( 1.36 acres) of water covered sediment in an area located approximately 0.20 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)

(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes. The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0014 is to the north, (called north as orientated with the north to south flow of the Connecticut River), survey unit 9521 is to the east, Discharge Canal Survey Unit 9106-0003 is to the south and Survey Area 9520 is to the west. The Survey Unit comprises the canal sediments to the depth of three (3) feet from the top of the sediment layer or the original construction depth and it extends up the canal banks to the mean high water level.

This survey unit is bounded by reference coordinates E006 through E010 by S077 through S081 (refer to License Termination Plan Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0002 as Class 2 in May 2006.

The "ClassificationBasis Summary" conducted for this survey unit consisted of:

a) A review of the IOCFR50.75 (g) (1) database, b) A review of the "InitialCharacterizationReport" and the "HistoricSite Assessment (HSA) Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

e) Formal or informal interviews with cognizant personnel.

A review of the IOCFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment. The sample analyses indicated that the Revision 0 3

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86). None the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.

Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00). These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.

An initial characterization survey of the Discharge Canal was performed during April and May of 2004. However, none of these samples were taken from within the footprint of Survey Unit 9106-0002.

A final characterization was performed by Site Closure personnel in April of 2006 to obtain the necessary data of sufficient data quality for Final Status Survey (FSS) planning purposes. Seven (7) 3-foot core sediment samples were taken from seven (7) locations. All of the samples were analyzed by gamma spectroscopy. Hard-to-Detect analyses were also conducted on one (1) of the seven (7) samples. Sr-90 was found to be a nuclide of concern based on the analysis of the sample. Since a variance cannot be determined from one (1) sample result, the variance associated with the fifteen (15) characterization samples measured for Sr-90 in an adjacent Survey Unit (SU9106-0003) was applied. Although no additional HTD testing was performed for characterization; four (4) of the fifteen (15) samples taken to demonstrate compliance with the release criteria during FSS were tested for the full suite of HTD nuclides to provide additional assurance that all of the radionuclides of concern were appropriately addressed. As a result of characterization, the radionuclides of concern identified for FSS planning purposes were Cs-137, Co-60 and Sr-90 (refer to Table 1).

Revision 0 4

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Table I -- BasicStatisticl Quantities*for s437Co60 and Sr-9** from the Paae --- I Cs-137 (pCiig) Co-60' (pijg) Sr-90 (pCiu )

Minimum Value: 4.58E-02 -4.90E-03 9.43E-04 Maximum Value: 3.93E-01 2.53 E-01 3.77E-02 Mean: 1.64E-01 9.59E-02 1.45E-02 Median: 1.53E-01 8.72E-02 1.08E-02 Standard Deviation: 1.18E-01 7.94E-02 1.1OE-02 NOTE: The Operational DCGLs are 5.38 pCi/g for Cs-137, 2.59 pCi/g for Co-60 and 1.05 for Sr-90; these are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE The FSS Engineer performed a visual inspection and walkdown during May 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLsjustifying a final survey unit classification of Class 2 (refer to Section 3).

3. DATA QUALITY OBJECTIVES (DQO)

FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparationof FinalStatus Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.

The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0002 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the Revision 0 5 Revision 0 5

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL),

for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.

As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario. Consequently, the soil DCGLs are directly applied to the canal sediment media.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation I shows the mathematical relationship between the three (3) components and the total dose.

Equation 1:

HTotal=Hsoil (sediment) +/- HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey unit is affected by existing groundwater, but is unaffected by future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from existing groundwater is two (2) mrem/yr TEDE, based on field data.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings remaining within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contributions from future groundwater, the third component is, therefore, zero (0) mrem/yr TEDE.

Revision 0 6 Revision 0 6

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Equation 2.

19 mrem/yriotal= 17 mrem/yrsoil+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is nineteen (19 )mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

Revision 0 7 Revision 0 7

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Table: 2- Radionuclide Specific BaseGCase Soil DCGL, Operational DCGGs and Reuuired Minimum Detectable Concentrations, Radionuclide 'i Base Case Soil 0perational DCGL Rqie lD H-3 DCGL (pCi/g) (2) wK(pCi/ 1 (3)() (PCi/gj) (4)

H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+O1 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+O1 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+0I Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Characterization was performed in April and May of 2004 as discussed in Section 2. Cesium-137, Cobalt-60 and Strontium-90 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137, Co-60 and Sr-90 are provided in Table 1.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (<MDC) were not accepted for FSS. Sample report Revision 0 8

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparationof Final Status Survey Plans ".

This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined. Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is seventeen (17) mrem/yr TEDE, as discussed in Section 2 of this Release Record.

The DQO process determined that Cs-137, Co-60 and Sr-90 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Sr-90) were considered in the survey design.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Sr-90 concentrations in sediment and soil were ascertained by direct analysis.

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%

for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected. This process was applied to analysis data for this survey unit.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.

The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in Revision 0 9 Revision 0 9

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD accordance with Procedure RPM 5.1-11 to 0.867 to maintain the relative shift (A/a) in the range of I and 3. The resulting relative shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for. implementation of MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Subsequent to the initial design, the northern boundary of the survey unit was moved southward. The following are summary explanations of the design considerations and how these affected Survey Unit 9106-0002:

  • An adjacent survey unit (SU 9106-0001) was reclassified to a Class I area.
  • Since SU 9106-0001 exceeded the 2000 m2 size limit for a Class I area, it was divided into a northern survey unit (SU 9106-0001) and a southern survey unit (SU 9106-0014).

" In order to maximize the area of the two (2) Class I Survey Units, the boundaries of Survey Units 9106-0002 and 9106-0014 were pushed southward.

  • Changing the boundaries placed three (3) statistical sample locations (001F, 003F and 006F) and one (1) bias sample location (016F) outside of Survey Unit 9106-0002.
  • The affected statistical sample locations were replaced with three (3) randomly generated sample locations (017F, 018F and 019F).
  • The biased location was not relocated as it was placed to target an area of interest that was removed from the survey unit as a consequence of the boundary change.

Revision 0 10 Revision 0 10

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table 3 -Sample Measur~ement Locations withbAss-ociated GPS Coordinates Designati *Northing *% Ea~stiig 9106-0002-002F 236170.95 669239.34 9106-0002-004F 236106.91 669202.36 9106-0002-005F 236106.91 669276.31 9106-0002-007F 236042.86 669165.39 9106-0002-008F 236042.86 669239.34 9106-0002-009F 236042.86 669313.29 9106-0002-01 OF 235978.82 669202.36 9106-0002-01 IF 235978.82 669276.31 9106-0002-012F 235978.82 669350.26 9106-0002-013F 235978.82 669424.21 9106-0002-014F 235914.78 669313.29 9106-0002-015F 235914.78 669387.24 9106-0002-017F 236170.95 669165.39 9106-0002-018F 236170.95 669239.34 9106-0002-019F 236106.91 669128.41 Although Procedure RPM 5.1-11 specifies that only 5% of the samples need to be selected for HTD analysis, four (4) soil samples were analyzed for HTDs, exceeding the 5% procedural requirement. Two (2) samples were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RAND" function. In addition, two (2) samples, which were determined to contribute the greatest dose based on gamma only analyses, were also selected for HTD analyses. Each sample would be sent off-site for a full suite analysis of the HTD radionuclides specified in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RAND" function. The number of quality control samples exceeded the LTP requirement of 5%.

The LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.

Revision 0 I1I

DISCH4ARGE CANAL SURVEY UNIT 9 106-0002 RELEASE RECORD survey unit 2 tsasea on AUtOAL)-L i ana v isuai 5,520 m Land Area Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was .0666. the LBGR was set to Measurements 0.867 to maintain Relative Shift in the range of I and 3, Relative Shift was 2.0 Grid Spacing 20.61 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve 10 mrem/yr TEDE 0.62 pCi/g Sr-90 Operational 5.38 pCi/g Cs-137 To achieve 17 mrem/yr Oril 2.59 pCi/g Co-60 TEDE (2)to demonstrate compliance with 1.05 pCi/g Sr-90 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 5.3 8 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.59 pCi/g Co-60 criteria for a Class 2 survey unit Level 1.05 pCi/g Sr-90 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the total dose from existing and future groundwater has been established (reference CY memo ISC 06-024)

5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021. The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Survey, Inc.

(OSI) of Old Saybrook, Connecticut. Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments. Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten feet or less).

A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample Revision 0 12

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD locations were accomplished using a GPS interfaced with a navigation and data logging system.

After extraction, water was drained from above the sample by drilling holes above the sediment. The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. " Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.

The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Mediafor FinalStatus Survey ". Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Four. (4) samples (9106-0002-004F, 9106-0002-007F, 9106-0003-0011 and 9106-0003-012F) were selected for HTD radionuclide analysis by the off-site laboratory.

The implementation of quality control measures included the collection of two (2) split samples at locations 9106-0002-014F and 9106-0002-018F for comparative analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) - Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy. Sr-90 was analyzed by gas flow proportional counting. All analyses were performed to the required MDC.

Cesium-137 met the acceptance criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) in thirteen (13), Co-60 met the accepance criteria for detection in fourteen (14) and Sr-90 met the acceptance criteria for detection in two (2) of the fifteen (15) samples.

Several other radionuclides that met the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.

The off-site laboratory also processed four (4) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. Four Revision 0 13

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD (4) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.

None of the sample results exceeded the Operational DCGL or required further investigation. A summary of the sample results is provided in Table 5.

91 Ub-UUU2-UU21t 2.64L-02 2. 13E-U0 9.&iz -Ui Z.ZDL-U2 9106-0002-004F 1.23E-01 1.19E-01 7.1 OE-03 7.56E-02 9106-0002-005F 1.98E-01 2.88E-01 7.01E-03 1.55E-01 9106-0002-007F 3.81 E-01 6.39E-01 6.81 E-02 3.82E-01 9106-0002-008F 1.63E-01 3.70E-01 7.85E-03 1.81E-01 9106-0002-009F 1.84E-01 2.31E-01 2.94E-03 I1.26E-0 I 9106-0002-01 OF 6.61 E-02 2.38E-01 -1.06E-02 9.41 E-02 9106-0002-011 F 2.47E-01 5.26E-01 1.95E-02 2.68E-01 9106-0002-012F 1.75E-01 1.1 8E-01 -4.47E-03 7.38E-02 9106-0002-013F 2.431E-02 1.51 E-0 1 -4.97E-04 6.23E-02 9106-0002-014F 0.OOE+00 1.46E-03 -2.35E-03 -1.67E-03 9106-0002-01 5F 1.166E-01 5.07E-02 4.55E-03 4.55E-02 9106-0005-017F 9.30E-02 8.07E-02 2.14E-02 6.88E-02 9106-0005-018F 8.09E-02 1.45E-01 7.58E-03 7.82E-02 9106-0005-019F 1.69E-01 1.21 E-01 -1.31 E-02 6.57E-02 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137, 2.59 pCi/g for Co-60 and 1.05 for Sr-90; these are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE Biased sampling was not required to resolve anomalies or to account for survey unit irregularities.

7. QUALITY CONTROL The two (2) split samples taken for QC were analyzed by the off-site laboratory.

The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " One (1) split-sample (9106-0002-018F/S) did not meet the comparison criterion for Co-60. A possible cause for this anomaly could be the presence of Co-60 in the form of discrete particles. Such a physical form does not lend itself to homogenous mixing in a sediment matrix and, therefore, is not necessarily an indicator of inadequate sampling or sample preparation methodology. In this sample, Cs-137 and K-40, a natural radioisotope, were both found to be present at acceptable levels of agreement, therefore, the comparison was determined to be Revision 0 14 Revision 0 14

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD acceptable. For the other QC split samples, there was an acceptable level of agreement between the samples for the radionuclides of concern.

The sample analysis vendor, GEL, maintained quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

8. INVESTIGATIONS AND RESULTS Sample investigation levels were not exceeded for this unit, consequently none were performed.
9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE, which was conservative and necessary at the time of FSS planning. It is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used to demonstrate compliance with the LTP criteria is seventeen (17) mrem/yr TEDE as discussed in Section 2 of this Release Record.
11. DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passes FSS.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

Revision 0 15

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2g. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of the LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.

Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.

The range of the data, about 3.84 standard deviations, was not unusually large.

The difference between the mean and median was 37.5% of the standard deviation which indicates some skewness in the data. The data's represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.69.

All data, assessments, and graphical representations are provided in Attachment 2.

12. ANOMALIES The anomaly associated with the disagreement between the field split number 9106-0002-018F/S has been discussed in Section 7. The source of the disagreement for Co-60, was likely due to Co-60 being present in the form of discrete particles. Such a physical form does not lend itself to homogenous mixing in a sediment matrix. However, comparisons of results for other radionuclides present in the sample were sufficient to demonstrate appropriate implementation of sampling Quality Controls.
13. CONCLUSION Survey Unit 9106-0002 has demonstrated compliance with the dose based, unrestricted release criterion. The sample data passed the Sign Test and the null hypothesis was rejected. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Reclassification and remediation of this survey unit was not required.

Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as a Class 2 survey unit.

The dose contribution from sediment in this survey unit is 1.9 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

Revision 0 16

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is bounded by 2.0 mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, 0 mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3.9 mrem/yr Total Effective Dose Equivalent (TEDE).

14. ATTACHMENTS 14.1 Attachment I - Figures 14.2 Attachment 2 - Sample and Statistical Data Revision 0 17

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 1 Figures (4 pages)

Connecticut Yankee Atomic Power Company FigISite Map With Reference To Survey Unit 9106-0002

owl 0 0

13 Dw to 4 12 C-W Current 8 Swvey Unit Boundwy 0 15 Bondayof Ame Removed 7 Suivey Unit 0 17 to Become Padl Of 9106-004.

Wetlands Note 0 20 40 Connecticut Yankee Atomic Power Company 9106-0002FinalStatus Survey Sample Locations

E:1),ý 0 A ctual Sample Locaton as 0 zacoided by Ocean Siuveys, Inc.

SwtveyPlan Due to Bound&y 0.123 chanp 0.175 - Crrent Survey Unit 0.163 Bounday 0.116 Ame 0.247 Removed Aum Onig&W Survey Unit 0.381 tu eome 0.093 Pmtl Of 9106-004.

4Li4 Wegands Notes Points 1,3,6 and 16 lie outside the revigdabou0d0y for 9106-0002 Cesiumn-37zasults re giveninpCilg.

0 20 40 Ltomic PowerC fStatus Survey ostina Plot

%ýý 0, D --0

- \11o 0

~)Actual Sample Locadon as 0 worxded by Ocean Sorveys Inc.

SurveyPlan Due to 0.151 Bouadai 0.119 chaw 0 0.118 Survey Unit 0.37 0 Boundaiy 0 0.051 __Boundiy Arm of 0.526 0 Removed fim Orn&W Survey Unt 0.639 to Become 0 0.081 Prtof 9106-0014.

~\Lwetlands NMtes Points 1,3,6and 16 lie outside the zmiyed bounduy for 9106-0002 Cobalt-60results aregiven in pCig.

0 20 40

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2 Sample and Statistical Data

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2a Sample Data (229 Pages)

Table of Contents G eneral Narrative .................................................................. 1 Chain of Custody and Supporting Documentation ........... 4 Radiological Analysis .......................................................... 11 Sample Data Summary ...................................................... 30 Q uality C ontrol D ata ........................................................... 62

General Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 164220 SDG: MSR #06-0755 June 30, 2006 Laboratory Identification:

General Engineering Laboratories, LLC MailingZ Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on June 02, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 164220001 9106-0002-OOIF 164220002 9106-0002-002F 164220003 9106-0002-003F 164220004 9106-0002-004F 164220005 9106-0002-005F 164220006 9106-0002-006F 164220007 9106-0002-006FS 164220008 9106-0002-007F 164220009 9106-0002-008F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

P.O. Box 30712 - Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax r43) 766-1178 ° www.gel.com

164220010 9106-0002-009F 164220011 9106-0002-OIOF 164220012 9106-0002-01 IF 164220013 9106-0002-012F 164220014 9106-0002-013F 164220015 9106-0002-014F 164220016 9106-0002-014FS 164220017 9106-0002-015F 164220018 9106-0002-016F Items of Note:

There are no items of note.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Sixteen sediment samples were analyzed for FSSGAM and Sr-90.

Two sediment samples were analyzed for FSSALL.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

P.O. Box 30712

  • Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (843) 766-1178 . www.gel.com

Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn 4.

Priority: Z 30 D. E] 14 D. L] 7 D. Sample Container Size- ,dq Z

  • Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-001Fe 5/17/06 10:42 SE C BP X X Transferred from COC 2006-00357 rLI 9106-0002-002F 5/18/06 09:43 SE C BP X Transferred from COC 2006-00361 9106-0002-003F& 5/18/06 10:14 SE C BP X X Transferred from COC 2006-003 61 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F' 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP X x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP X X Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal o- 55 Z Fed Ex Container El UPS Temp.:

CajLa ~ 0-b-~ r~lo(6A Deg. C Cj- o ;l. Hand Custody Sealed?

Rel qu By Date/Time 2) .ived By Date/Time Custody Seal M  ;"-aO LI Other Intact?

I)Telinqtuished 9 Date/Time 4) Received By Date/Time YO NO Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time 7'09 9/16 .7/0

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody FormNo206037 Connecticut Yankee Atomic Power Company No. 2006-00372 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 <

843 556 8171. Attn. Cheryl Jones L C ,

Priority: E 30 D. F] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 ON~ 9106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-011 F 5/19/06 08:10 SE C BP X X Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-014FSjo 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal 0755 [ Fed Ex Container 4

El UPS Temp.:

  • A

'-~c% +iuA*L1 1 0ovt4v'; O~e4- C b i$/&Deg. C El,.uHand Custody Sealed?

1 Rel*n '*h *y Date/Time 2) ReMved By Dat Time Custody Seal

, ( *o~ El Other Intact?

3)x(elinquished By Date/Time 4) Received By Date/Time BillofLdin9Y E N E

5) Relinquished By Date/Time 6) Received By Date/Time 7'qoq z/Y'" z57 1~c1 Bill of Lading B

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-O01 Figure 1. Sample Check-in List.

Date/Time Received: *) -,

')V 2 9Q SDG#:

Work Order Number:-. . L 2 - "

Shipping Cdntainer ID] P(O Y!L,5I2/4' Chain of Custody #

  • 4 cQ" 7!
1. Custody Seals ori shipping container intact?.. -Yes No[ ]
2. Custody Seals dated and signed? Yes JN [No

].

3. Chain-of-Custody record present? Yes ,TNo ]
4. Cooler temperature _ 9.

. Vermiculite/packing materials is: Wet [ ] Dry , Ofe h 5

5.

6." Number of samples in shipping container:

7. Sample -

holdingv times exceeded? Yes f 1 No I

--- " " -- 1N

,8. Samples have:

-tape -hazard labels

..cstody seals -- appropriIate sample labels

9. Samples are..'

.-4 in good condition "-leaking

-broken ... -.have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ ] NoX]
11. Description of anomalies (include sample numbers):

Sample. Custodian/Laboratory:- _ _ Date.

Telephoned to: * --. On By-

. .

7

FORM SAMPLE RECEIPT & REVIEW PM use only 0

Client: (navoe4 1 cr ý (f u k 'e. .SDGIARCOC/Work Order: (L'22C) items are resolved prior to signing):

Review (ensure non-cotaonning Date Received: 'PM(A)

Received By:

Items)

Z Comments/Qualibrers (Required for Non-Conforming Sample Receipt Criteria other (describe) g container damaged container Ie Applicable: seals broken Circle S hip peCing codtainer s r ci ved n ac and sealed? blue ice dry ice none other describe)

Circle Coolant # ice bags Samples requiring cold 2 preservation within (4 +I-/- 2 C)?

-Record preservation method.____________________________

3Chain of custody documents ..... _ _ _

3 included with shipment? leaking container other idescribe)

Circle Applicablesea1s broken damaged container 4 Sample containers intact and lsealed? affected and observ.d p.:

-conta.iners Sanjp.I. &Sm I Samples requiring chemical I___________________I________

preservation atproper pH?

C ncrs a _:

6 I (defined as < 6mm bubble)? I Are Encore containers present?

I 7 (If yes, immediately deliver to VOA laboratorv) /

Id's and tests affected:

Samples received wi " holding time? I/

affcted:

'Sample tDs and containers

)

Sample ID's 9 a'COC match ID's on bottles?/

Sample ID's affected:

Date & tme on COC match date I& tit 6 on bottles?

I Sample ID's affected:

l Nufber of containers received match number indicated on COC?

99 12 COC form is properly signed in C ý&-2,00 (e -003T relinquished/received sections? 1

--

&

14'Air Bill ,Tracking #'s, Additional Comments I non hiulher V Z RSO RAD Receipt_

background is observedthe on

___

samples Radiation

____#

Safety group identified as fornon-if >

, rd InRArRceitn x2 area ,

contact I

zard Inform ation ap reguJated/non-radioactive" Suspected Ha " ,'

ax Ix investigation.

M xm mCO nsObserved*:

asif,"in? -

A Radiological Comments:

"-

B FB Rgulated 3U azRgar ous Hazard Class Shipped:

C Material? If yess, contact Waste r N#:

Manager or ES l Manager. Date:

Initials PM (or PMA) reeview of Hazard classiticationw B

Connecticut Yankee Statement of Work for Analytical Lab Services .cy-Isc-sow-001I Figure 1. Sample Check-in List.

Date/Time Received &/Tk(2 SDG#: -o -qo Work Order Number:.QLA"-' '["

Cctainer I "Shipping Chain of Custody3

1. Custody Seals on" shipping container intact? "Yes No []
2. Custody Seals dated and signed? Yes A] No [ ]
3. Chain-of-Custoly record present? e. Yes No []

.4. Cooler temperature

5. Vermiculite/packing materials is: Wet [ Dry j3] *OCI*(fJ -

6.' Number of samples in shipping container: ____

7. Sample holding times exceeded? Yes [ No
8. Samples have:

___hazard

-tape labels

-Custody seals appropriate sample labels

9. Samples are.'

.. in good condition -leaking

-broken - have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ No -
11. Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:f; . Date.: 6 "o ""

Telephoned to: On - .y

" 9

- SAMPLE RECEIPT & REVIEW FORM 0

PM use only CI Date Received: fecF1L Cie-Tnt: (0(

o ec [ SDG/ARCOCi'Werk PM(A) Review ( non-conro reOrder: &C-'yozoug i are reoved prior to signing):

Received By:I Sample Receipt Criteria Comments/Qualifiers equired for Non-Conforming Items) damaged container leaking container other (describe)

Circle Applicable: seals broke 1 Shipping containers received intact and sealed? 1 7 Samples requiring cold Circle Coolant # ic ags blue ice dry ice none other describe) 2 preservation within (4 +/- 2 C)?

Record preservation method.

Chain of custody documents included with shipment?

4 Sample containers intact and Cird Applicable: seals broken damaged container leaking container odter (describe) sealed?

5 Samples requiring chemical Sample ID's. containers affected and observed pH:

preservalion at proper pH?

Sample ID's and containers affected:

6 VOA vials free of headspace (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received within holdin Idas and tests affected:

time? /

9 Sample ID's on COC lnatc ID's Sample ID's and containers affected:

on bottles?

Date & time on COC tch date Sample ID's affected:

&time on bottles? _

Number of container received Sample ID's affected:

match number indic ted on COC?

12 COC form is propirly signed in _""-2 relinquished/received sections? coc-- Z G - ec5. CA*

  • &6,1 I" Air Bill ,Tracking #s, &

Additional Comments 10 "V Z RSO RAD Receipt #

Suspected Hazard In formation - *If > x2 area background is observed on samples identified as "non-

,jU . regulated/non-radioactive", contact the Radiation Safety group for further A_RadiologicalClassification? investigation.

Radiological Classification? Maximum Counts Observed-; r Pm B PCB Regulated? Comments:

jShipped as DOT Hazardous c MMaterial? If yes, contact Waste Hazard Class Shipped:

NManager or ESH Manager. UN#:

PM (or PMA) review of Hazard classitication: Initials Date: Lpj[- 0(

10

RADIOLOGICAL ANALYSIS 11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 164220 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 540462 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201117597 Method Blank (MB) 1201117598 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201117599 164220002(9106-0002-002F) Matrix Spike (MS) 1201117600 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1201117598 (9106-0002-002F) was recounted due to a peak shift.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 13

Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 540464 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201117601 Method Blank (MB) 1201117602 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201117603 164220002(9106-0002-002F) Matrix Spike (MS) 1201117604 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

14

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 540465 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 15

Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201117605 Method Blank (MB) 1201117606 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201117607 164220002(9106-0002-002F) Matrix Spike (MS) 1201117608 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1201117605 (MB) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: EML HASL 300,4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 536186 Prep Batch Number: 535666 Sample ID Client ID 164220002 9106-0002-002F 164220004 9106-0002-004F 164220005 9106-0002-005F 164220007 9106-0002-006FS 164220008 9106-0002-007F 164220009 9106-0002-008F 164220010 9106-0002-009F 164220011 9106-0002-01OF 164220012 9106-0002-01 IF 164220013 9106-0002-012F 164220014 9106-0002-013F 164220015 9106-0002-014F 164220017 9106-0002-015F 164220018 9106-0002-016F 1201107352 Method Blank (MB) 1201107353 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201107354 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 17

narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information 18

Qualifier Reason Analyte Sample U1 Data rejected due to high full width half maximum. Cesium-134 164220012 Cesium- 137 164220015 Manganese-54 164220014 UI Data rejected due to interference. Europium-155 164220010 164220012 164220018 Manganese-54 164220015 U' Data rejected due to low abundance. Cesium- 134 164220005 164220007 164220017 164220018 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 539388 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 19

Sample ID Client ID 164220002 9106-0002-002F 164220004 9106-0002-004F 164220005 9106-0002-005F 164220007 9106-0002-006FS 164220008 9106-0002-007F 164220009 9106-0002-008F 164220010 9106-0002-009F 164220011 9106-0002-01OF 164220012 9106-0002-01 IF 164220013 9106-0002-012F 164220014 9106-0002-013F 164220015 9106-0002-014F 164220017 9106-0002-015F 164220018 9106-0002-016F 1201114898 Method Blank (MB) 1201114899 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201114900 164220002(9106-0002-002F) Matrix Spike (MS) 1201114901 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s)

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

20

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 164220014 (9106-0002-013F) was recounted due to being originally counted on a detector that did not meet daily background and efficiency checks. Sample 164220013 (9106-0002-012F) was recounted due to the activity of the sample being between two and three sigma TPU.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 536314 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201107610 Method Blank (MB) 1201107611 163741008(9106-0008-007F) Sample Duplicate (DUP) 1201107612 163741008(9106-0008-007F) Matrix Spike (MS) 1201107613 Laboratory Control Sample (LCS) 21

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 163741008 (9106-0008-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

22

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 538969 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201113887 Method Blank (MB) 1201113888 163741008(9106-0008-007F) Sample Duplicate (DUP) 1201113889 163741008(9106-0008-007F) Matrix Spike (MS) 1201113890 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

23

Designated QC The following sample was used for QC: 163741008 (9106-0008-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni- 1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 541000 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 24

Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201118869 Method Blank (MB) 1201118870 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201118871 164220002(9106-0002-002F) Matrix Spike (MS) 1201118872 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 25

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 535984 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201106885 Method Blank (MB) 1201106886 163626016(9106-0007-001 F) Sample Duplicate (DUP) 1201106887 163626016(9106-0007-001F) Matrix Spike (MS) 1201106888 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

26

Designated QC The following sample was used for QC: 163626016 (9106-0007-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 536336 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201107670 Method Blank (MB) 1201107671 164220002(9106-0002-002F) Sample Duplicate (DUP) 1201107672 164220002(9106-0002-002F) Matrix Spike (MS) 1201107673 Laboratory Control Sample (LCS) 27

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

28

Oualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

29

SAMPLE DATA

SUMMARY

30

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-0755 GEL Work Order: 164220 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the reporting limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-002F Project: YANK01204 Sample ID: 164220002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 14.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0378 +/-0.0665 0.0376 +/-0.0666 0.165 pCi/g MXA 06/22/06 1119 540462 1 1

Curium-242 U 0.00 +/-0.0752 0.00 +/-0.0752 0.104 pCi/g Curium-243/244 U 0.0331 +/-0.0649 0.00 +/-0.065 0.0897 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.032 +/-0.0628 0.00 +/-0.0629 0.0868 pCi/g MXA 06/22/06 1119 540464 2 1

Plutonium-239/240 U -0.19 +/-0.124 0.210 +/-0.125 0.506 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-9.79 7.84 +/-9.82 16.4 pCi/g MXA 06/23/06 2100 540465 3 1

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.646 +/-0.123 0.0498 +/-0.123 0.107 pCi/g MJHI 06/19/06 2034 536186 4 Americitim-241 U 0.0463 +1-0.0455 0.0844 +/-0.0455 0.174 pCi/g Bismuth-212 0.497 +/-0.194 0.113 +/-0.194 0.239 pCi/g Bismuth-214 0.534 +/-0.0856 0.025 +/-0.0856 0.053 pCi/g Cesium-134 U 0.0362 +/-0.0269 0.0185 +/-0.0269 0.0391 pCi/g Cesium-137 U 0.0264 +/-0.0177 0.0168 +/-0.0177 0.0353 pCi/g Cobalt-60 U 0.0213 +/-0.0149 0.016 +/-0.0149 0.0349 pCi/g Europium-152 U 0.00263 +1-0.0455 0.039 +/-0.0455 0.0813 pCi/g Europium-154 U -0.00291 +/-0.0636 0.0464 +/-0.0636 0.100 pCi/g Europium-155 U 0.0554 +/-0.0468 0.0458 +/-0.0468 0.0943 pCi/g Lead-212 0.703 +/-0.0499 0.0233 +/-0.0499 0.0481 pCi/g Lead-214 0.602 +/-0.0664 0.0272 +/-0.0664 0.0569 pCi/g Manganese-54 U 0.00163 +/-0.0184 0.0156 +/-0.0184 0.0331 pCi/g Niobium-94 U 0.00959 +/-0.014 0.0127 +/-0.014 0.0269 pCi/g Potassium-40 9.42 +/-0.696 0.115 +/-0.696 0.257 pCi/g Radium-226 0.534 +/-0.0856 0.025 +/-0.0856 0.053 pCi/g Silver-108m U 0.0101 +/-0.0162 0.0115 +/-0.0162 0.0244 pCi/g Thallium-208 0.227 +/-0.0424 0.014 +/-0.0424 0.0296 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9 O, solid-ALL FSS Strontium-90 U 0.00983 +/-0.0153 0.015 +/-0.0153 0.0339 pCi/g BXF1 06/25/06 1024 539388 5 Rad Liquid Scintillation Analysis 32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-002F Proiect: YANKO 1204 Sample ID: 164220002 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier R Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 3.84 +/-6.26 5.04 +/-6.26 10.6 pCi/g NXPI 06/17/06 1642 535984 6 Liquid Scint C14, SolidAllFSS Carbon-14 U -0. 0461 +/-0.0864 0.0732 +/-0.0864 0.148 pCi/g ATH2 06/16/06 0624 536336 7 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 10.2 +/-17.9 13.1 +/-18.0 27.7 pCi/g SLNI 06/21/06 0845 538969 8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 4.21 +/-5.83 4.77 +/-5.83 9.82 pCi/g SLN1 06/28/06 0021 541000 9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -( 0.122 +/-0.211 0.182 +/-0.211 0.375 pCi/g SXEI 06/14/06 1747 536314 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1919 535666 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-l1-RC Modified 3 DOE EML HASL-300, Pu-I1-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-I, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 92 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 86 (15°/o-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 83 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 87 (15%-125%)

33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-002F Project: YANKO 1204 Sample ID: 164220002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 74 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 83 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

  • QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-004F Project: YANKO 1204 Sample ID: 164220004 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 17.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.601 +/-0.162 0.0507 +/-0.162 0.110 pCi/g MJH1 06/20/06 0609 536186 1 Americium-241 U 0.0156 +/-0.0229 0.020 +/-0.0229 0.0411 pCi/g Bismuth-212 0.375 +/-0.210 0.114 +/-0.210 0.244 pCi/g Bismuth-214 0.387 +/-0.0828 0.0295 +/-0.0828 0.0624 pCi/g Cesium-134 U 0.0216 +/-0.0203 0.0192 +/-0.0203 0.0407 pCi/g Cesium-137 0.123 +/-0.0376 0.0158 +/-0.0376 0.0335 pCi/g Cobalt-60 0.119 +/-0.0405 0.0151 +/-0.0405 0.0333 pCi/g Europium- 152 U 0.0142 +/-0.0433 0.0394 +/-0.0433 0.0824 pCi/g Europium- 154 U -0.0342 +/-0.0602 0.0476 +/-0.0602 0.104 pCi/g Europium-155 U 0.0127 +/-0.0398 0.0364 +/-0.0398 0.0751 pCi/g Lead-212 0.535 +/-0.0754 0.0224 +/-0.0754 0.0464 pCi/g Lead-214 0.435 +/-0.0879 0.0287 +/-0.0879 0.060 pCi/g Manganese-54 U 0.0193 +/-0.0241 0.0182 +/-0.0241 0.0386 pCi/g Niobium-94 U - 6.520E- +/-0.0183 0.0154 +/-0.0183 0.0327 pCi/g 05 Potassium-40 9.32 +/-0.884 0.122 +/-0.884 0.274 pCi/g Radium-226 0.387 +/-0.0828 0.0295 +/-0.0828 0.0624 pCi/g Silver-108m U - -0.00653 +/-0.0164 0.014 +/-0.0164 0.0295 pCi/g Thallium-208 0.165 +/-0.0417 0.0157 +/-0.0417 0.0332 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0071 +/-0.0176 0.0183 +/-0.0176 0.0408 pCi/g BXFI 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1919 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-004F Proiect: YANK01204 Sample ID: 164220004 Client ID: YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-005F Proiect: YANKO 1204 Sample ID: 164220005 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 18.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.796 +/-0.176 0.0562 +/-0.176 0.121 pCi/g MJHI 06/19/06 2036 536186 1 Americium-241 U 0.064 +/-0.0949 0.0669 +/-0.0949 0.139 pCi/g Bismuth-212 0.621 +/-0.246 0.124 +/-0.246 0.265 pCi/g Bismuth-214 0.572 +/-0.107 0.0285 +/-0.107 0.0607 pCi/g Cesium-134 UI 0.00 +/-0.0246 0.0212 +/-0.0246 0.0449 pCi/g Cesium-137 0.198 +/-0.0401 0.0177 +/-0.0401 0.0375 pCi/g Cobalt-60 0.288 +/-0.0484 0.0149 +/-0.0484 0.0329 pCi/g Europium- 152 U -0.03 +/-0.0499 0.0428 +/-0.0499 0.090 pCi/g Europium- 154 U -0.0212 +/-0.0594 0.0475 +/-0.0594 0.104 pCi/g Europium- 155 U 0.0189 +/-0.0589 0.0539 +/-0.0589 0.112 pCi/g Lead-212 0.765 +/-0.0851 0.0266 +/-0.0851 0.0555 pCi/g Lead-214 0.618 +/-0.0965 0.0303 +/-0.0965 0.0639 pCi/g Manganese-54 U -0.0127 +/-0.0192 0.0157 +/-0.0192 0.0338 pCi/g Niobium-94 U 0.0223 +/-0.0189 0.0136 +/-0.0189 0.0291 pCi/g Potassium-40 10.2 +/-0.990 0.128 +/-0.990 0.287 pCi/g Radium-226 0.572 +/-0.107 0.0285 +/-0.107 0.0607 pCi/g Silver-108m U7.0)20E-05 +/-0.0166 0.0145 +/-0.0166 0.0307 pCi/g Thallium-208 0.219 +/-0.0403 0.014 +/-0.0403 0.030 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.00701 +/-0.0155 0.0159 +/-0.0155 0.0356 pCi/g BXF1 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1919 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPIC, Sr90, solid-ALL FSS 75 (25%-/125%)

37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-005F Proiect: YANK01204 Sample ID: 164220005 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-006FS Project: YANKO 1204 Sample ID: 164220007 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 9.72%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.565 +/-0.182 0.074 +/-0.182 0.164 pCi/g MJHI 06/19/06 2036 536186 1 Americium-241 U 0.0249 +/-0.0997 0.0944 +/-0.0997 0.197 pCi/g Bismuth-212 U 0.325 +/-0.322 0.178 +/-0.322 0.387 pCi/g Bismuth-214 0.508 +/-0.128 0.0387 +/-0.128 0.0839 pCi/g Cesium-134 UI 0.00 +/-0.0409 0.0272 +/-0.0409 0.059 pCi/g Cesium-137 0.0576 +/-0.0404 0.0227 +/-0.0404 0.0491 pCi/g Cobalt-60 0.128 +/-0.0573 0.0194 +/-0.0573 0.0448 pCi/g Europium-152 U --0.00196 +/-0.0607 0.0546 +/-0.0607 0.117 pCi/g Europium-154 U -0.0619 +/-0.0812 0.0613 +/-0.0812 0.139 pCi/g Europium-155 U 0.0375 +/-0.075 0.0631 +/-0.075 0.132 pCi/g Lead-212 0.680 +/-0.0717 0.0322 +/-0.0717 0.0677 pCi/g Lead-214 0.599 +/-0.110 0.0396 +/-0.110 0.0845 pCi/g Manganese-54 U 0.0149 +/-0.0283 0.0251 +/-0.0283 0.0543 pCi/g Niobium-94 U - -0.00622 +/-0.0219 0.018 +/-0.0219 0.0394 pCi/g Potassium-40 10.5 +/-1.02 0.173 +/-1.02 0.407 pCi/g Radium-226 0.508 +/-0.128 0.0387 +/-0.128 0.0839 pCi/g Silver-108m U -0.0207 +/-0.0197 0.0157 +/-0.0197 0.0342 pCi/g Thallium-208 0.239 +/-0.0474 0.0222 +/-0.0474 0.0479 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00243 +/-0.0125 0.0135 +/-0.0125 0.0306 pCi/g BXF1 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-/125%)

39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-006FS Proiect: YANKO 1204 Sample ID: 164220007 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANK01204 Sample ID: 164220008 Client ID: YANK001 Matrix: SE Vol. Recv.:

.18-MAY-06 Collect Date:

Receive Date: 02-JUN-06 Collector: Client Moisture: 22.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rod Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.728 +/-0.174 0.0585 +/-0.174 0.123 pCi/g MJH1 06/19/06 2036 536186 1 Americium-241 U 0.0662 +/-0.0842 0.0732 +/-0.0842 0.150 pCi/g Bismuth-212 0.503 +/-0.246 0.110 +/-0.246 0.231 pCi/g Bismuth-214 0.582 +/-0.0888 0.0274 +/-0.0888 0.0573 pCi/g Cesium-134 U 0.0324 +/-0.0315 0.0192 +/-0.0315 0.0401 pCi/g Cesium-137 0.381 +/-0.0456 0.0153 +/-0.0456 0.0321 pCi/g Cobalt-60 0.639 +/-0.0719 0.0156 +/-0.0719 0.0336 pCi/g Europium-152 U - -0.00433 +/-0.0445 0.037 +/-0.0445 0.0768 pCi/g Europium-154 U -0.0143 +/-0.0575 0.0475 +/-0.0575 0.101 pCi/g Europium-155 U 0.0619 +/-0.0536 0.0408 +/-0.0536 0.0837 pCi/g Lead-212 0.809 +/-0.0817 0.0216 +/-0.0817 0.0445 pCi/g Lead-214 0.690 +/-0.0992 0.0263 +/-0.0992 0.0546 pCi/g Manganese-54 U 0.0152 +/-0.0203 0.0176 +/-0.0203 0.0368 pCi/g Niobium-94 U - 0.00868 +/-0.016 0.0131 +/-0.016 0.0275 pCi/g Potassium-40 12.9 +/-1.11 0.115 +/-1.11 0.253 pCi/g Radium-226 0.582 +/-0.0888 0.0274 +/-0.0888 0.0573 pCi/g Silver-108m U -0.0107 +/-0.0149 0.0127 +/-0.0149 0.0264 pCi/g Thallium-208 0.238 +/-0.041 0.0144 +/-0.041 0.0301 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00681 +/-0.0131 0.0131 +/-0.0131. 0.0298 pCi/g BXFl 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier[Tracer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-125%)

41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Proiect: YANKO 1204 Sample ID: 164220008 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-008F Project: YANK01204 Sample ID: 164220009 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 20.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.574 +/-0.132 0.0514 +/-0.132 0.109 pCi/g MJH1 06/20/06 0610 536186 1 Americium-241 U -0.0538 +/-0.107 0.0921 +/-0.107 0.191 pCi/g Bismuth-212 0.294 +/-0.232 0.109 +/-0.232 0.232 pCi/g Bismuth-214 0.388 +/-0.0771 0.0245 +/-0.0771 0.0518 pCi/g Cesium- 134 U 0.0325 +/-0.040 0.0187 +/-0.040 0.0394 pCi/g Cesium-137 0.163 +/-0.0295 0.0127 +/-0.0295 0.0271 pCi/g Cobalt-60 0.370 +/-0.052 0.0129 +/-0.052 0.0283 pCi/g Europium- 152 U 0.0234 +/-0.0428 0.0379 +/-0.0428 0.0792 pCi/g Europium-154 U 0.0429 +/-0.0592 0.0479 +/-0.0592 0.103 pCi/g Europium-155 U 0.0179 +/-0.0447 0.0428 +/-0.0447 0.0884 pCi/g Lead-212 0.584 +/-0.0721 0.0217 +/-0.0721 0.0451 pCi/g Lead-214 0.470 +/-0.0851 0.0247 +/-0.0851 0.0519 pCi/g Manganese-54 U 0.00381 +/-0.0184 0.0158 +/-0.0184 0.0334 pCi/g Niobium-94 U - 0.00332 +/-0.0142 0.012 +/-0.0142 0.0255 pCi/g Potassium-40 9.79 +/-0.887 0.112 +/-0.887 0.250 pCi/g Radium-226 0.388 +/-0.0771 0.0245 +/-0.0771 0.0518 pCi/g Silver-108m U-0 .000506 +/-0.0146 0.0131 +/-0.0146 0.0275 pCi/g Thallium-208 0.207 +/-0.0334 0.012 +/-0.0334 0.0255 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00785 +/-0.0154 0.0156 +/-0.0154 0.035 pCi/g BXFI 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-/125%)

43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-008F Project: YANKO 1204 Sample ID: 164220009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-009F Project: YANKO 1204 Sample ID: 164220010 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 20.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.127 +/-0.168 0.110 +/-0.169 0.318 pCi/g MXA 06/22/06 1119 540462 1 Curium-242 U -0.0507 +/-0.0445 0.108 +/-0.0449 0.330 pCi/g Curium-243/244 U 0.0131 +/-0.136 0.138 +/-0.136 0.374 pCi/g Alphaspec Pu, Solid ALL FSS Plutonium-238 U -0.0153 +/-0.0792 0.0972 +/-0.0792 0.289 pCi/g MXA 06/22/06 1119 540464 2 1

Plutonium-239/240 U - -0.00835 +/-0.0164 0.0397 +/-0.0164 0.174 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.1 +/-12.6 10.1 +/-12.7 21.2 pCi/g MXA 06/23/06 2116 540465 3 1

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.668 +/-0.149 0.0513 +/-0.149 0.110 pCi/g MJH1 06/20/06 0917 536186 4 Americium-241 U -0.0183 +/-0.0763 0.0635 +/-0.0763 0.131 pCi/g Bismuth-212 0.708 +/-0.214 0.101 +/-0.214 0.216 pCi/g Bismuth-214 0.520 +/-0.0732 0.025 +/-0.0732 0.0529 pCi/g Cesium-134 U 0.0398 +/-0.035 0.021 +/-0.035 0.044 pCi/g Cesium- 137 0.184 +/-0.045 0.0138 +/-0.045 0.0294 pCi/g Cobalt-60 0.231 +/-0.0461 0.0144 +/-0.0461 0.0316 pCi/g Europium-152 U -0.0209 +/-0.0407 0.0355 +/-0.0407 0.0743 pCi/g Europium-154 U 0.00108 +/-0.048 0.0405 +/-0.048 0.0883 pCi/g Europium-155 UI 0.00 +/-0.0613 0.0374 +/-0.0613 0.0774 pCi/g Lead-212 0.664 +/-0.0487 0.0199 +/-0.0487 0.0413 pCi/g Lead-214 0.524 +/-0.0743 0.0252 +/-0.0743 0.0528 pCi/g Manganese-5 4 U - 0.00262 +/-0.0182 0.0158 +/-0.0182 0.0335 pCi/g Niobium-94 U 0.00538 +1-0.0155 0.0134 +/-0.0155 0.0283 pCi/g Potassium-40 10.2 +/-0.675 0.122 +/-0.675 0.271 pCi/g Radium-226 0.520 +/-0.0732 0.025 +/-0.0732 0.0529 pCi/g Silver-108m U 0.0034 +/-0.0143 0.0128 +/-0.0143 0.0268 pCi/g Thallium-208 0.216 +/-0.0341 0.0145 +/-0.0341 0.0306 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00294 +/-0.017 0.0184 +/-0.017 0.0412 pCi/g BXFI 06/25/06 1025 539388 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-009F Project: YANKO 1204 Sample ID: 164220010 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U - -2.65 +/-7.23 6.22 +/-7.23 13.1 pCi/g NXPI 06/17/06 1658 535984 6 Liquid Scint C14, SolidAllFSS Carbon-14 U -0. 0114 +/-0.0887 0.0746 +/-0.0887 0.151 pCi/g ATH2 06/16/06 0757 536336 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 5.52 +/-16.7 12.3 +/-16.7 25.9 pCi/g SLN1 06/21/06 0902 538969 8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 4.87 +/-6.73 5.51 +/-6.74 11.3 pCi/g SLN1 06/28/06 0108 541000 9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0. 0368 +/-0.224 0.187 +/-0.224 0.386 pCi/g SXEI 06/14/06 1804 536314 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-11-RC Modified 3 DOE EML HASL-300, Pu-11-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-1, Modified 9 DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 97 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 92 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu 2 4 1, Solid-ALL Fý 65 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 98 (15%-125%)

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-009F Project: YANK01204 Sample ID: 164220010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 67 (25%-125 %)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-OIOF Project: YANK01204 Sample ID: 164220011 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 13.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.817 +/-0.139 0.0579 +/-0.139 0.125 pCi/g MJH1 06/20/06 1008 536186 1 Americium-241 U 0.0037 +/-0.0906 0.0728 +/-0.0906 0.150 pCi/g Bismuth-212 0.765 +/-0.247 0.131 +/-0.247 0.279 pCi/g Bismuth-214 0.647 +/-0.103 0.0322 +/-0.103 0.0681 pCi/g Cesium-134 U 0.0149 +/-0.0278 0.0208 +/-0.0278 0.0442 pCi/g Cesium- 137 0.0661 +/-0.0378 0.0167 +/-0.0378 0.0356 pCi/g Cobalt-60 0.238 +1-0.0552 0.0158 +/-0.0552 0.0351 pCi/g Europium- 152 U -0.0245 +/-0.0532 0.0443 +/-0.0532 0.0928 pCi/g Europium-154 U -0.0219 +/-0.0613 0.0508 +/-0.0613 0.111 pCi/g Europium- 155 U 0.0559 +/-0.0498 0.0482 +/-0.0498 0.0993 pCi/g Lead-212 0.760 +/-0.0605 0.026 +/-0.0605 0.0539 pCi/g Lead-214 0.736 +/-0.093 0.0315 +/-0.093 0.066 pCi/g Manganese-54 U -0.0136 +/-0.0204 0.0163 +/-0.0204 0.035 pCi/g Niobium-94 U 0.0204 +/-0.0198 0.0163 +/-0.0198 0.0345 pCi/g Potassium-40 10.5 +/-0.808 0.134 +/-0.808 0.302 pCi/g Radium-226 0.647 +/-0.103 0.0322 +/-0.103 0.0681 pCi/g Silver-108m U - -0.00471 +/-0.018 0.0148 +/-0.018 0.0312 pCi/g Thallium-208 0.285 +/-0.048 0.017 +/-0.048 0.036 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U -0.0106 +/-0.0136 0.0176 +/-0.0136 0.0392 pCi/g BXFI 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr9O, solid-ALL FSS 72 (25%-125%)

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-010F Project: YANK01204 Sample ID: 164220011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

  • QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01IF Proiect: YANKO 1204 Sample ID: 164220012 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 18%

Parameterr Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actiniun-228 0.555 +/-0.154 0.0668 +/-0.154 0.142 pCi/g MJH1 06/20/06 1009 536186 1 Americium-241 U -0.0836 +/-0.106 0.0669 +/-0.106 0.138 pCi/g Bismuth-212 0.411 +/-0.209 0.114 +/-0.209 0.243 pCi/g Bismuth-214 0.547 +/-0.0669 0.0275 +/-0.0669 0.0584 pCi/g Cesium-134 UI 0.00 +/-0.0507 0.0177 +/-0.0507 0.0378 pCi/g Cesium-137 0.247 +/-0.0433 0.0191 +/-0.0433 0.0402 pCi/g Cobalt-60 0.526 +/-0.0598 0.014 +/-0.0598 0.0311 pCi/g Europium- 152 U 0.0154 +/-0.0455 0.0415 +/-0.0455 0.0868 pCi/g Europium-154 U 0.0336 +/-0.0642 0.0509 +/-0.0642 0.110 pCi/g Europium- 155 Ul 0.00 +/-0.0713 0.0413 +/-0.0713 0.0853 pCi/g Lead-212 0.656 +/-0.0521 0.0235 +/-0.0521 0.0487 pCi/g Lead-214 0.634 +/-0.078 0.0282 +/-0.078 0.059 pCi/g Manganese-54 U 0.0135 +/-0.022 0.0192 +/-0.022 0.0406 pCi/g Niobium-94 U 0.0146 +/-0.0161 0.0146 +/-0.0161 0.031 pCi/g Potassium-40 11.1 +/-0.820 0.123 +/-0.820 0.276 pCi/g Radium-226 0.547 +/-0.0669 0.0275 +/-0.0669 0.0584 pCi/g Silver-108m U 0.00368 +/-0.0156 0.014 +/-0.0156 0.0294 pCi/g Thallium-208 0.227 +/-0.0428 0.0153 +/-0.0428 0.0324 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.0195 +/-0.0167 0.0147 +/-0.0167 0.0333 pCi/g BXF1 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFP'C, Sr90, solid-ALL FSS 75 (25%- 125%)

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-011F Proiect: YANKO 1204 Sample ID: 164220012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils P0# 002332 Client Sample ID: 9106-0002-012F Proiect: YANKO 1204 Sample ID: 164220013 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 18.5%

Parameter .Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.650 +1-0.151 0.0574 +/-0.151 0.122 pCi/g MJH1 06/20/06 1009 536186 1 Americium-241 U -0.126 +/-0.0935 0.0727 +/-0.0935 0.149 pCi/g Bismuth-212 0.513 +/-0.177 0.112 +/-0.177 0.238 pCi/g Bismuth-214 0.542 +/-0.0844 0.0265 +/-0.0844 0.0561 pCi/g Cesium-134 U 0.0281 +/-0.0349 0.0197 +/-0.0349 0.0416 pCi/g Cesium-137 0.175 +/-0.0364 0.0164 +/-0.0364 0.0346 pCi/g Cobalt-60 0.118 +/-0.0405 0.0174 +/-0.0405 0.0376 pCi/g Europium-152 U 0.0354 +/-0.0583 0.0455 +/-0.0583 0.0944 pCi/g Europium-154 U -0.0546 +/-0.0598 0.0448 +/-0.0598 0.0974 pCi/g Europium-155 U 0.0313 +/-0.0553 0.0511 +/-0.0553 0.105 pCi/g Lead-212 0.757 +/-0.0554 0.0264 +1-0.0554 0.0545 pCi/g Lead-214 0.605 +/-0.0866 0.0296 +/-0.0866 0.0618 pCi/g Manganese-54 U -0.0096 +/-0.021 0.0174 +/-0.021 0.0368 pCi/g Niobium-94 U 0.00277 +/-0.0174 0.0152 +/-0.0174 0.032 pCi/g Potassium-40 10.6 +/-0.817 0.140 +/-0.817 0.309 pCi/g Radium-226 0.542 +/-0.0844 0.0265 +/-0.0844 0.0561 pCi/g Silver-108m U 0.00453 +/-0.0174 0.0149 +/-0.0174 0.0311 pCi/g Thallium-208 0.291 +/-0.0438 0.0152 +/-0.0438 0.0321 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.00447 +/-0.0108 0.0132 +/-0.0108 0.0297 pCi/g BXFI 06/26/06 2133 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-012F Project: YANK01204 Sample ID: 164220013 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldo I-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-013F Proiect: YANK01204 Sample ID: 164220014 Client ID: YANKOOl Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 24.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS Actinium-228 0.688 +/-0.198 0.0782 +/-0.198 0.167 pCi/g MJHI 06/20/06 1010 536186 1 Americium-241 U 0,0271 +/-0.0326 0.0281 +/-0.0326 0.0577 pCi/g Bismuth-212 0.421 +/-0.302 0.135 +/-0.302 0.289 pCi/g Bismuth-214 0.662 +/-0.100 0.0365 +/-0.100 0.0772 pCi/g Cesium-134 U 0.0486 +/-0.0403 0.0255 +/-0.0403 0.054 pCi/g Cesium-137 U 0.0243 +/-0.052 0.0235 +/-0.052 0.0496 pCi/g Cobalt-60 0.151 +/-0.0486 0.0224 +/-0.0486 0.0488 pCi/g Europium-152 U -0.02 +/-0.0504 0.044 +/-0.0504 0.0925 pCi/g Europium-154 U 0.00563 +/-0.0667 0.057 +/-0.0667 0.125 pCi/g Europium-155 U 0.0391 +1-0.051 0.0471 +/-0.051 0.0968 pCi/g Lead-212 0.723 +/-0.0651 0.0256 +/-0.0651 0.0532 pCi/g Lead-214 0.640 +/-0.0947 0.0361 +/-0.0947 0.0755 pCi/g Manganese-54 UI 0.00 +/-0.0774 0.0219 +/-0.0774 0.0467 pCi/g Niobium-94 U 0.00857 +/-0.0228 0.0198 +/-0.0228 0.0418 pCi/g Potassium-40 10.1 +/-0.836 0.190 +/-0.836 0.419 pCi/g Radium-226 0.662 +/-0.100 0.0365 +/-0.100 0.0772 pCi/g Silver-108m U 0.00113 +/-0.0192 0.0169 +/-0.0192 0.0356 pCi/g Thallium-208 0.289 +/-0.054 0.0193 +/-0.054 0.0408 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U-0.000497 +/-0.0108 0.0122 +/-0.0108 0.0276 pCi/g BXF1 06/26/062133 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-013F Project: YANK01204 Sample ID: 164220014 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrierf/racer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-0125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-014F Proiect: YANK01204 Sample ID: 164220015 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 10.5%

Parameter Qualifier 'Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.636 +/-0.149 0.0475 +/-0.149 0.103 pCi/g MJHI 06/20/06 1018 536186 1 Americium-241 U 0.0288 +/-0.0915 0.0757 +/-0.0915 0.156 pCi/g Bismuth-212 0.739 +/-0.253 0.101 +/-0.253 0.216 pCi/g Bismuth-214 0.644 +/-0.0996 0.0268 +/-0.0996 0.0567 pCi/g Cesium-134 U 0.0302 +/-0.0267 0.0188 +/-0.0267 0.0398 pCi/g Cesium-137 UT 0.00 +/-0.0443 0.0147 +/-0.0443 0.0312 pCi/g Cobalt-60 U 0.00146 +/-0.0214 0.0183 +/-0.0214 0.0395 pCi/g Europium-152 U - 0.00893 +/-0.0433 0.0366 +/-0.0433 0.0767 pCi/g Europium-154 U -0.0447 +/-0.0542 0.0418 +/-0.0542 0.0916 pCi/g Europium- 155 U 0.0758 +/-0.0609 0.0408 +/-0.0609 0.0843 pCi/g Lead-212 0.828 +/-0.0856 0.0225 +/-0.0856 0.0467 pCi/g Lead-214 0.740 +/-0.103 0.0245 +/-0.103 0.0515 pCi/g Manganese-54 UI 0.00 +/-0.0228 0.0149 +/-0.0228 0.0318 pCi/g Niobium-94 U 0.0196 +/-0.0261 0.0143 +/-0.0261 0.0303 pCi/g Potassium- 4 0 10.4 +/- 1.03 0.119 +/-1.03 0.268 pCi/g Radium-226 0.644 +/-0.0996 0.0268 +/-0.0996 0.0567 pCi/g Silver-108m U -0.0088 +/-0.0138 0.0119 +/-0.0138 0.0252 pCi/g Thallium-208 0.249 +/-0.0461 0.0144 +/-0.0461 0.0306 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U - 0.00235 +/-0.016 0.0184 +/-0.016 0.0406 pCi/g BXFI 06/25/06 1026 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier[Fracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-014F Project: YANK01204 Sample ID: 164220015 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-015 F Project: YANKO 1204 Sample ID: 164220017 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 13%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.820 +/-0.214 0.060 +/-0.214 0.129 pCi/g MJHI 06/20/06 1019 536186 1 Americium-241 U 0.0169 +/-0.0299 0.0251 +/-0.0299 0.0514 pCi/g Bismuth-212 0.473 +/-0.305 0.131 +/-0.305 0.280 pCi/g Bismuth-214 0.791 +/-0.135 0.0338 +/-0.135 0.0713 pCi/g Cesium-134 UI 0.00 +/-0.0379 0.0247 +/-0.0379 0.0521 pCi/g Cesium-137 0.116 +/-0.0374 0.0202 +/-0.0374 0.0427 pCi/g Cobalt-60 0.0507 +/-0.0319 0.0175 +/-0.0319 0.0385 pCi/g Europium-152 U -0.0307 +/-0.0547 0.047 +/-0.0547 0A0979 pCi/g Europium-154 U 0.075 +/-0.0721 0.0658 +/-0.0721 0.141 pCi/g Europiun- 155 U 0.0281 +/-0.0479 0.0433 +/-0.0479 0.089 pCi/g Lead-212 0.886 +/-0.115 0.0252 +1-0.115 0.0521 pCi/g Lead-214 0.771 +/-0.119 0.0334 +/-0.119 0.0697 pCi/g Manganese-54 U 0.0219 +/-0.0304 0.0173 +/-0.0304 0.0371 pCi/g Niobium-94 U -0.0027 +/-0.0201 0.0166 +/-0.0201 0.0352 pCi/g Potassium-40 11.9 +/-1.11 0.154 +/-1.11 0.342 pCi/g Radium-226 0.791 +Z-0.135 0.0338 +/-0.135 0.0713 pCi/g Silver-]108m U 0.00556 +/-0.0176 0.0155 +/-0.0176 0.0326 pCi/g Thallium-208 0.232 +/-0.056 0.0187 +/-0.056 0.0394 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.00455 +/-0.0169 0.0179 +/-0.0169 0.0405 pCi/g BXFI 06/25/06 1120 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 64 (25%-125%)

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-015F Project: YANKO 1204 Sample ID: 164220017 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-016F Proiect: YANKO 1204 Sample ID: 164220018 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 19.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.973 +/-0.156 0.0312 +/-0.156 0.0651 pCi/g MJH1 06/20/06 1019 536186 1 Americium-241 U 0.0182 +/-0.0728 0.0685 +/-0.0728 0.140 pCi/g Bismuth-212 0.682 +/-0.202 0.0693 +/-0.202 0.144 pCi/g Bismuth-214 0.800 +/-0.0822 0.0174 +/-0.0822 0.036 pCi/g Cesium-134 UI 0.00 +/-0.0173 0.0121 +/-0.0173 0.0249 pCi/g Cesium-137 0.0731 +/-0.0225 0.00992 +/-0.0225 0.0205 pCi/g Cobalt-60 0.0983 +/-0.0254 0.0104 +/-0.0254 0.0218 pCi/g Europium-152 U 0.0105 +/-0.0316 0.0267 +/-0.0316 0.0546 pCi/g Europium- 154 U 0.0338 +/-0.0361 0.0305 +/-0.0361 0.0637 pCi/g Europium- 155 UI 0.00 +/-0.0463 0.0294 +/-0.0463 0.0598 pCi/g Lead-212 1.01 +/-0.102 0.0157 +/-0.102 0.0321 pCi/g Lead-214 0.929 +/-0.0992 0.0187 +/-0.0992 0.0383 pCi/g Manganese-54 U 0.00934 +/-0.0177 0.00934 +/-0.0177 0.0194 pCi/g Niobium-94 U 0.00509 +/-0.0109 0.00939 +/-0.0109 0.0194 pCi/g Potassium-40 10.5 +/-0.809 0.0876 +/-0.809 0.185 pCi/g Radium-226 0.800 +/-0.0822 0.0174 +/-0.0822 0.036 pCi/g Silver-108m U - 0.00238 +/-0.00976 0.00854 +/-0.00976 0.0176 pCi/g Thallium-208 0.283 +/-0.0333 0.00953 +/-0.0333 0.0197 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00915 +/-0.0171 0.0173 +/-0.0171 0.0389 pCi/g BXF1 06/25/06 1053 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (2501.-125%)

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-016F Project: YANK01204 Sample ID: 164220018 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

61

QUALITY CONTROL DATA 62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Renort Date: June 29, 2006 Client: Connecticut Yankee Atomic Power Page 1 of 9 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 164220 Parmname NOM Sample Oual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 540462 QC1201117598 164220002 DUP Americium-241 U -0.0378 U -0.106 pCi/g 95 (0%- 100%) vXAI 06/24/06 08:10 Uncert: +/-0.0665 +/-0.182 TPU: +/-0.0666 +/-0.183 Curium-242 U 0.00 U 0.0639 pCi/g 200 (0% - 100%)

Uncert: +/-0.0752 +/-0.147 TPU: +/-0.0752 +/-0.147 Curium-243/244 U 0.0331 U 0.102 pCi/g 102 (0%- 100%)

Uncert: +/-0.0649 +/-0.270 TPU: +/-0.065 +/-0.270 QC1201117600 LCS Americium-241 13.6 10.3 pCi/g 76 (75%-125%) 06/22/06 11:19 Uncert: +/- 1.09 TPU: +/-1.63 Curium-242 U 0.0229 pCi/g Uncert: +/-0.0607 TPU: +/-0.0608 Curium-243/244 16.6 15.4 pCi/g 93 (75%-125%)

Uncert: +/-1.33 TPU: +/-2.26 QC1201117597 MB Americium-241 U 0.054 pCi/g 06/22/06 11:19 Uncert: +/-0.148 TPU: +/-0.149 Curium-242 U 0.107 pCi/g Uncert: +/-0.164 TPU: +/-0.165 Curium-243/244 U 0.123 pCi/g Uncert: +/-0.238 TPU: +/-0.238 QC1201117599 164220002 MS Americium-241 13.7 U -0.0378 10.3 pCi/g 75 (75%-125%)

Uncert: +/-0.0665 +/-2.01 TPU: +/-0.0666 +/-2.68 Curium-242 U 0.00 U -0.0497 pCi/g Uncert: +/-0.0752 +/-0.257 TPU: +/-0.0752 +/-0.257 Curium-243/244 16.7 U 0.0331 15.8 pCi/g 95 (75%-125%)

Uncert: +/-0.0649 +/-2.52 TPU: +/-0.065 +/-3.70 Batch 540464 QCI201117602 164220002 DUP Plutonium-238 U 0.032 U 0.018 pCi/g 56 (0%- 100%) IXAI 06/22/06 11:19 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 2 of 9 Parmname NOM Sample Oual OC Units RPD% REC% Ranee Anist Date Time Rad Alpha Spec Batch 540464 Uncert: +/-0.0628 +/-0.0717 TPU: +/-0.0629 +/-0.0717 Plutonium-239/240 U -0.19 U 0.018 pCi/g 242 (0%- 100%)

Uncert: +/-0.124 +/-0.0716 TPU: +/-0.125 +/-0.0716 QCI201117604 LCS Plutonium-238 U 0.0504 pCi/g (75%-125%)

Uncert: +/-0.0944 TPU: +/-0.0946 Plutonium-239/240 12.6 11.2 pCi/g 89 (75%-125%)

Uncert: +/-1.19 TPU: +/-1.67 QC1201117601 MB Plutonium-238 U 0.00 pCi/g Uncert: +/-0.0707 TPU: +/-0.0707 Plutonium-239/240 U 0.0462 pCi/g Uncert: +/-0.104 TPU: +/-0.104 QC1201117603 164220002 MS Plutonium-238 U 0.032 U 0.0403 pCi/g (75%-125%)

Uncert: +/-0.0628 +/-0.091 TPU: +/-0.0629 +/-0.0911 Plutonium-239/240 12.6 U -0.19 11.2 pCi/g 89 (75%-125%)

Uncert: +/-0.124 +/-1.17 TPU: +/-0.125 +/-1.63 Batch 540465 QC1201117606 164220002 DUP Plutonium-241 U 8.31 U 2.27 pCi/g 0 (0% - 100%) IXAI 06/23/06 21:49 Uncert: +/-9.79 +/-8.87 TPU: +/-9.82 +/-8.88 QCI201117608 LCS Plutonium-241 140 117 pCi/g 83 (75%-125%) 06/23/06 22:22 Uncert: +/-14.6 TPU: +/-18.8 QC1201117605 MB Plutonium-241 U -3.1 pCi/g 06/29/06 00:04 Uncert: +/-10.1 TPU: +/-10.1 QC1201117607 164220002 MS Plutonium-241 142 U 8.31 110 pCi/g 77 (75%-125%) 06/23/06 22:05 Uncert: +/-9.79 +/-13.0 TPU: +/-9.82 +/-16.6 Rad Gamma Spec Batch 536186 QC1201107353 164220002 DUP Actinium-228 0.646 0.606 pCi/g 6 (0%- 100%) MJHI 06/20/06 10:19 Uncert: +/-0.123 +/-0.212

+/-0.212 64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 3 of 9 Parmname NOM Samole Oual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 536186 TPU: +/-0.123 Americium-241 U 0.0463 U -0.00516 pCi/g 250 (0%- 100%)

Uncert: +/-0.0455 +/-0.0334 TPU: +/-0.0455 +/-0.0334 Bismuth-212 0.497 0.499 pCi/g 0 (0%- 100%)

Uncert: +/-0.194 +/-0.314 TPU: +/-0.194 +/-0.314 Bismuth-214 0.534 0.624 pCi/g 16 (0%- 100%)

Uncert: +/-0.0856 +/-0.0957 TPU: +/-0.0856 +/-0.0957 Cesium- 134 U 0.0362 U 0.0393 pCi/g 8 (0%- 100%)

Uncert: +/-0.0269 +/-0.0379 TPU: +/-0.0269 +/-0.0379 Cesium-137 U 0.0264 U 0.0144 pCi/g 59 (0%- 100%)

Uncert: +/-0.0177 +/-0.0255 TPU: +/-0.0177 +/-0.0255 Cobalt-60 U 0.0213 U 0.0279 pCi/g 27 (0%- 100%)

Uncert: +/-0.0149 +/-0.0414 TPU: +/-0.0149 +/-0.0414 Europium- 152 U 0.00263 U 0.0158 pCi/g 143 (0%- 100%)

Uncert: +/-0.0455 +/-0.0602 TPU: +/-0.0455 +/-0.0602 Europium- 154 U -0.00291 U -0.0319 pCi/g 167 (0%- 100%)

Uncert: +/-0.0636 +/-0.0859 TPU: +/-0.0636 +/-0.0859 Europium- 155 U 0.0554 U 0.0481 pCi/g 14 (0%- 100%)

Uncert: +/-0.0468 +/-0.0651 TPU: +/-0.0468 +/-0.0651 Lead-212 0.703 0.787 pCi/g II (0% - 20%)

Uncert: +/-0.0499 +/-0.0603 TPU: +/-0.0499 +/-0.0603 Lead-214 0.602 0.659 pCi/g 9 (0%- 20%)

Uncert: +/-0.0664 +/-0.106 TPU: +/-0.0664 +/-0.106 Manganese-54 U 0.00163 U 0.00979 pCi/g 143 (0%- 100%)

Uncert: +/-0.0184 +/-0.0222 TPU: +/-0.0184 +/-0.0222 Niobium-94 U 0.00959 U 0.0335 pCi/g III (0%- 100%)

Uncert: +/-0.014 +/-0.0355 TPU: +/-0.014 +/-0.0355 Potassium-40 9.42 9.25 pCi/g 2 (0%- 20%)

Uncert: +/-0.696 +/-0.703 TPU: +/-0.696 +/-0.703 Radium-226 0.534 0.624 pCi/g 16 (0%- 100%)

Uncert: +/-0.0856 +/-0.0957 TPU: +/-0.0856 +/-0.0957 Silver-108m U 0.0101 U -0.00367 pCi/g 429 (0%- 100%)

Uncert: +/-0.0162 +/-0.0229 65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 4 of 9 Parmname NOM Samplek Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 536186 TPU: +/-0.0162 +/-0.0229 Thallium-208 0.227 0.278 pCi/g 20 (0%- 100%)

Uncert: +/-0.0424 +/-0.0495 TPU: +/-0.0424 +/-0.0495 QC1201107354 LCS Actinium-228 U -0.00213 pCi/g 06/20/06 10:20 Uncert: +/-0.430 TPU: +/-0.430 Amnericium-241 23.4 26.5 pCi/g 113 (75%-125%)

Uncert: +/-1.24 TPU: +/-1.24 Bismuth-212 U 0.0167 pCi/g Uncert: +/-0.830 TPU: +/-0.830 Bismuth-214 U 0.110 pCi/g Uncert: +/-0.223 TPU: +/-0.223 Cesium- 134 U 0.00152 pCi/g Uncert: +/-0.120 TPU: +/-0.120 Cesium- 137 9.63 10.6 pCi/g 110 (75%-125%)

Uncert: +/-0.401 TPU: +/-0.401 Cobalt-60 15.0 16.4 pCi/g 110 (75%-125%)

Uncert: +/-0.584 TPU: +/-0.584 Europium- 152 U 0.349 pCi/g Uncert: +/-0.247 TPU: +/-0.247 Europium- 154 U 0.089 pCi/g Uncert: +/-0.277 TPU: +/-0.277 Europium- 155 U 0.0129 pCi/g Uncert: +/-0.317 TPU: +/-0.317 Lead-212 U 0.0378 pCi/g Uncert: +/-0.159 TPU: +/-0.159 Lead-214 U 0.0858 pCi/g Uncert: +/-0.180 TPU: +/-0.180 Manganese-54 U -0.0333 pCi/g Uncert: +/-0.104 TPU: +/-0.104 Niobium-94 U 0.0477 pCi/g Uncert: +/-0.104 TPU: +/-0.104 Potassium-40 U 0.103 pCi/g 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 536186 Uncert: +/-0.950 TPU: +/-0.950 Radium-226 U 0.110 pCi/g (75%-125%)

Uncert: +/-0.223 TPU: +/-0.223 Silver-108m U 0.0477 pCi/g Uncert: +/-0.0984 TPU: +/-0.0984 Thallium-208 U 0.110 pCi/g Uncert: +/-0.104 TPU: +/-0.104 QC1201107352 MB Actinium-228 U 0.0667 pCi/g 06/19/06 20:38 Uncert: +/-0.0725 TPU: +/-0.0725 Americium-241 U 0.0113 pCi/g Uncert: +/-0.0873 TPU: +/-0.0873 Bismuth-212 U -0.000464 pCi/g Uncert: +/-0.101 TPU: +/-0.101 Bismuth-214 U 0.010 pCi/g Uncert: +/-0.0337 TPU: +/-0.0337 Cesium-134 U -0.00516 pCi/g Uncert: +/-0.0162 TPU: +/-0.0162 Cesium-137 U 0.00559 pCi/g Uncert: +/-0.0325 TPU: +/-0.0325 Cobalt-60 U -0.00201 pCi/g Uncert: +/-0.0154 TPU: +/-0.0154 Europium-152 U 0.000846 pCi/g Uncert: +/-0.0403 TPU: +/-0.0403 Europium- 154 U -7.7 1E-05 pCi/g Uncert: +/-0.0376 TPU: +/-0.0376 Europium-155 U 0.00972 pCi/g Uncert: +/-0.0384 TPU: +/-0.0384 Lead-212 U 0.0227 pCi/g Uncert: +/-0.026 TPU: +/-0.026 Lead-214 U 0.0215 pCi/g Uncert: +/-0.0287 TPU: +/-0.0287 67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 6 of 9 ParmnasmP NflMI Samnle nunal QC Units RPD% REC% Range Anist Parmname NOM Date Time Rad Gamma Spec Batch 536186 Manganese-54 U -0.00138 pCi/g Uncert: +/-0.0176 TPU: +/-0.0176 Niobium-94 U 0.0168 pCi/g Uncert: +/-0.0156 TPU: +/-0.0156 Potassium-40 U 0.301 pCi/g Uncert: +/-0.208 TPU: +/-0.208 Radium-226 U 0.010 pCi/g Uncert: +/-0.0337 TPU: +/-0.0337 Silver- 108m U -0.00382 pCi/g Uncert: +/-0.0128 TPU: +/-0.0128 Thallium-208 U 0.00659 pCi/g Uncert: +/-0.0142 TPU: +/-0.0142 Rad Gas Flow Batch 539388 QC0201114899 164220002 DUP Strontium-90 U 0.00983 U -0.0144 pCi/g 0 (0% --100%) BXFI 06/25/06 11:54 Uncert: +/-0.0153 +/-0.0118 TPU: +/-0.0153 +/-0.0118 QC1201114901 LCS Strontium-90 1.45 1.33 pCi/g 91 (75%-125%) 06/25/06 11:54 Uncert: +/-0.0832 TPU: +/-0.0894 QC1201114898 MB Strontium-90 U -0.0105 pCi/g 06/25/06 10:53 Uncert: +/-0.0112 TPU: +/-0.0112 QC1201114900 164220002 MS Strontium-90 1.46 U 0.00983 1.37 pCi/g 94 (75%-125%) 06/25/06 10:54 Uncert: +/-0.0153 +/-0.095 TPU: +/-0.0153 +/-0.103 Rad Liquid Scintillation Batch 535984 QC1201106886 163626016 DUP Tritium U 0.738 U -1.57 pCi/g 0 (0% - 100%) NXPI 06/17/06 17:31 Uncert: +/-6.97 +/-7.27 TPU: +/-6.97 +/-7.27 QC1201106888 LCS Tritium 52.7 55.2 pCi/g 105 (75%-125%) 06/17/06 18:04 Uncert: +/-9.22 TPU: +/-9.27 QC1201106885 MB Tritium U -0.845 pCi/g 06/17/06 17:15 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 7 of 9 Parmname NOM Sample Oual OC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 535984 Uncert: +/-5.81 TPU: +/-5.81 QC1201106887 163626016 MS Tritium 53.0 U 0.738 44.6 pCi/g 84 (75%-125%) 06/17/06 17:47 Uncert: +/-6.97 +/-8.62 TPU: +/-6.97 +/-8.66 Batch 536314 QC1201107611 163741008 DUP Technetium-99 U 0.196 U 0.273 pCi/g 0 (0% - 100%) SXEI 06/14/06 18:37 Uncert: +/-0.227 +/-0.233 TPU: +/-0.227 +/-0.233 QCI201107613 LCS Technetium-99 13.1 11.5 pCi/g 87 (75%-125%) 06/14/06 19:11 Uncert: +/-0.471 TPU: +/-0.540 QCI201107610 MB Technetium-99 U 0.090 pCi/g 06/14/06 18:20 Uncen: +/-0.200 TPU: +/-0.200 QC1201107612 163741008 MS Technetium-99 12.7 U 0.196 11.2 pCi/g 88 (75%-125%) 06/14/06 18:54 Uncert: +/-0.227 +/-0.494 TPU: +/-0.227 +/-0.557 Batch 536336 QC1201107671 164220002 DUP Carbon- 14 u -0.0461 U -0.0626 pCi/g 0 (0%- 100%) ATH2 06/16/06 11:05 Uncert: +/-0.0864 +/-0.0867 TPU: +/-0.0864 +/-0.0867 QC1201107673 LCS Carbon- 14 6.98 7.01 pCilg 100 (75%-125%) 06/16/06 14:06 Uncert: +/-0.173 TPU: +/-0.205 QCI201107670 MB Carbon- 14 U 0.032 pCilg 06/16/06 09:31 Uncert: +/-0.0872 TPU: +/-0.0872 QC1201107672 164220002 MS Carbon-14 7.03 U -0.0461 7.10 pCi/g 101 (75%-125%) 06/16/06 12:38 Uncert: +/-0.0864 +/-0.174 TPU: +/-0.0864 +/-0.206 Batch 538969 QC1201113888 163741008 DUP Iron-55 U 21.1 U -1.03 pCi/g 0 (0%- 100%) SLNI 06/21/06 10:23 Uncert: +/-18.3 +/-16.3 TPU: +/-18.5 +/-16.3 QC1201113890 LCS Iron-55 575 529 pCi/g 92 (75%-125%) 06/21/06 10:40 Uncert: +/-44.0 TPU: +/-86.2 69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 8 of 9 Parmname NOM Samole Oual OC Units RPD% REC% Ranee AnIst Date Time Rad Liquid Scintillation Batch 538969 QC1201113887 MB Iron-55 U 5.38 pCi/g 06/21/06 09:51 Uncert: +/-26.8 TPU: +/-26.8 QC1201113889 163741008 MS Iron-55 594 21.1 pCi/g U 546 92 (75%-125%) 06/21/06 10:07 Uncert: +/-18.3 +/-33.8 TPU: +/-18.5 +/-74.0 Batch 541000 QC1201118870 164220002 DUP Nickel-63 U 4.21 U 3.05 pCi/g 0 (0% - 100%) SLNI 06/28/06 18:29 Uncert: +/-5.83 +/-5.16 TPU: +/-5.83 +/-5.16 QC1201118872 LCS Nickel-63 167 149 pCi/g 90 (75%-125%) 06/28/06 20:03 Uncert: +/-4.20 TPU: +/-5.46 QC1201118869 MB Nickel-63 U 1.39 pCi/g 06/28/06 17:42 Uncert: +/-1.55 TPU: +/-1.55 QC1201118871 164220002 MS Nickel-63 513 U 4.21 469 pCi/g 91 (75%-125%) 06/28/06 19:16 Uncert: +/-5.83 +/-13.2 TPU: +/-5.83 +/-19.7 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164220 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

71

Table of Contents General Narrative .................................................................. 1 Chain of Custody and Supporting Documentation ........... 4 Radiological Analysis ........................................................... 7 Sample Data Summary ...................................................... 12 Q uality C ontrol D ata ........................................................... 22

IGeneral Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soils PO# 002332 Work Order: 164551 SDG: MSR #06-0819 June 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 164551001 9106-0002-017F 164551002 9106-0002-018F 164551003 9106-0002-018FS 16455t004 9106-0002-019F Items of Note:

There are no items of note.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

P.O. Box 30712 - Charleston, SC-29417 - 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax-1843) 766-1178 - www.gel.com

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Four soil samples were analyzed for FSSGAM and Sr-90.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, /NC.

P.O. Box 30712 - Charleston, SCJ9417

  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax-f843) 766-1178
  • www.gel.com

Chain of Custody and Supporting Documentation 4

GPP-GGGR-R5104-003-Attachment B-CY-001 Major Health Physics Procedure 11)

,~., V 1-5h/.-/

- I Chain of Custody Form No. 2006-00382 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested abSOnly Contact Name & Phone: Coi.,,. nts - "-

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) --

General Engineering Laboratories -

2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c * .

Priority: Z 30 D. [] 14 D. [: 7 D. Container Sample Size- -.  ;,

Media Type &Type Lab ID Sample Designation Date Time Code Code Code Comment, Preservation Lab SampleID 9106-0002-017F 6/2/06 12:49 SE C BP x X Transferred from COC 2006-00378 A-1 9106-0002-018F 6/2/06 13:15 SE C BP X X Transferred f-rom COC 2006-00378 9106-0002-018FS 6/2/06 13:15 SE C BP X x Transferred from COC 2006-00378 9106-0002-019F 6/2/06 13:45 SE C BP X X Transferred from COC 2006-00378 NOTES: PO #: 002332 MSR #: 06- 01/ISSWP# NA Z LTP QA R] Radwaste QA [I Non QA Samples Shipped Via: :Ilnt a i'-*

[ Fed Ex ,'Con*ainer' El UPS ... .em

) '.Deg. C E] Hand ý4Custody Sealed?

YFn N D 1)Relinquished By Date/Time 2) R d Date/Time iso dySealr,.ý

.D y-o Other  :.Intaet .

3) Relinquished By Date/Time 4) Received by Date/Time ;__y.__

. N- D Bill of Lading #

5) Relinquished By Date/Time 6)6)IIW Received

. By Receive B Date/Time71 rJ /63)

J 3-r " .. -

- 40 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check -in List Date/Time Received: - 0 ('

SDG#: M S (Z- C0(.O, 0' i Work Order Number: 2. 0 &

Shipping Cdutainer ID:_ - - Chain of Custody#- 40A- 0o0,-S;

1. Custody Seals. owshipping container intact?.. Yes *]' No [ ]
2. Custody Seals dated and signed? Yes [j No [4
3. Chain-of-Custody record present? Yes.* No [ ]
4. Cooler temperature ja o0
5. Vermiculite/packing materials is: Wet [ ] Dry 6.' Number of samples in shipping container:
7. Sample holding times exceeded? Yes L,! No (1
8. Samples have::

","tape hazard labels

  • i custody seals -appropriate sample labels
9. Samples are:

in good condition - -leaking broken - have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ ]No IL. Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:_iD___ _ __ _ Date._ 0 a.-

Telephoned to: -On By -

6

RADIOLOGICAL ANALYSIS 7

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 164551 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 538669 Prep Batch Number: 537133 Sample ID Client ID 164551001 9106-0002-017F 164551002 9106-0002-018F 164551003 9106-0002-018FS 164551004 9106-0002-019F 1201113174 Method Blank (MB) 1201113175 164551001(9106-0002-017F) Sample Duplicate (DUP) 1201113176 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.

8

Designated QC The following sample was used for QC: 164551001 (9106-0002-017F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The relative percent difference between samples 1201113175 (9106-0002-017F) and 164551001 (9106-0002-017F) for Bi-214, Ra-226 and Cs-137 did not meet the duplicate criteria. However, when a relative error ratio is calculated, precision is shown at 1.73 for Bi-214 and Ra-226 and 1.62 for Cs-137.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to interference. Europium-155 1201113175 UI Data rejected due to low abundance. Lead-212 1201113174 Potassium-40 1201113174 Method/Analysis Information 9

Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 541208 Prep Batch Number: 537134 Dry Soil Prep GL-RAD-A-021 Batch Number: 537133 Sample ID Client ID 164551001 9106-0002-017F 164551002 9106-0002-018F 164551003 9106-0002-018FS 164551004 9106-0002-019F 1201119317 Method Blank (MB) 1201119318 164551004(9106-0002-019F) Sample Duplicate (DUP) 1201119319 164551004(9106-0002-019F) Matrix Spike (MS) 1201119320 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 164551004 (9106-0002-019F).

QC Information 10

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

ZU)(j 0 Reviewer/Date:

11

SAMPLE DATA

SUMMARY

12

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-0819 GEL Work Order: 164551 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 13

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-017F Project: YANKO 1204 Sample ID: 164551001 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-JUN-06 Receive Date: 08-JUN-06 Collector: Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.706 +/-0.172 0.0626 +/-0.172 0.125 pCi/g MJHI 06/26/06 1940 538669 1 Americium-241 U 0.083 +/-0.0774 0.067 +/-0.0774 0.134 pCi/g Bismuth-212 0.404 +/-0.291 0.147 +/-0.291 0.293 pCi/g Bismuth-214 0.570 +/-0.101 0.0369 +/-0.101 0.0737 pCi/g Cesium- 134 U 0.0448 +/-0.0239 0.0232 +/-0.0239 0.0464 pCi/g Cesium-137 0.093 +/-0.0318 0.0208 +/-0.0318 0.0416 pCi/g Cobalt-60 0.0807 +/-0.0343 0.0197 +/-0.0343 0.0393 pCi/g Europium-152 U -0.0343 +/-0.0775 0.0542 +/-0.0775 0.108 pCi/g Europium-154 U 0.00799 +/-0.107 0.0497 +/-0.107 0.0994 pCi/g Europium-155 U -0.0483 +/-0.0626 0.0548 +/-0.0626 0.109 pCi/g Lead-212 0.623 +/-0.0817 0.0301 +/-0.0817 0.0602 pCi/g Lead-214 0.602 +/-0.103 0.0387 +/-0.103 0.0773 pCi/g Manganese-54 U 0.00262 +/-0.0217 0.0192 +/-0.0217 0.0384 pCi/g Niobium-94 U 0.0223 +/-0.0208 0.020 +/-0.0208 0.0399 pCi/g Potassium-40 9.46 +/-0.987 0.192 +/-0.987 0.385 pCi/g Radium-226 0.570 +/-0.101 0.0369 +/-0.101 0.0737 pCi/g Silver-108m U - 0.00347 +/-0.020 0.0174 +/-0.020 0.0348 pCi/g Thallium-208 0.212 +/-0.0455 0.0195 +/-0.0455 0.0389 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0214 +/-0.0159 0.0148 +/-0.0159 0.0323 pCi/g BXF1 07/05/06 1218 541208 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B LXM1 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 14

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-017F Project: YANK01204 Sample ID: 164551001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

15

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy.

Project: Soils PO# 002332 Client Sample ID: 9106-0002-018F Proiect: YANKO 1204 Sample ID: 164551002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-JUN-06 Receive Date: 08-JUN-06 Collector: Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.454 +/-0.144 0.0687 +/-0.144 0.137 pCi/g MJH1 06/26/06 1941 538669 1 Americium-241 U 0.0221 +/-0.119 0.0727 +/-0.119 0.145 pCi/g Bismuth-212 0.467 +/-0.313 0.123 +/-0.313 0.247 pCi/g Bismuth-214 0.431 +/-0.0859 0.0773 +/-0.0859 0.155 pCi/g Cesium-134 U 0.0169 +/-0.0277 0.0237 +/-0.0277 0.0473 pCi/g Cesium-137 0.0809 +/-0.0308 0.0183 +/-0.0308 0.0366 pCi/g Cobalt-60 0.145 +/-0.0417 0.0226 +/-0.0417 0.0452 pCi/g Europium-152 U -0.0334 +/-0.0666 0.0497 +/-0.0666 0.0994 pCi/g Europium-154 U -0.0109 +/-0.0649 0.0541 +/-0.0649 0.108 pCi/g Europium-155 U 0.0361 +/-0.0603 0.057 +/-0.0603 0.114 pCi/g Lead-212 0.493 +/-0.0723 0.0299 +/-0.0723 0.0598 pCi/g Lead-214 0.456 +/-0.0951 0.0364 +/-0.0951 0.0727 pCi/g Manganese-54 U 0.00174 +/-0.0234 0.0208 +/-0.0234 0.0417 pCi/g Niobium-94 U 0.0174 +/-0.0216 0.0198 +/-0.0216 0.0396 pCi/g Potassium-40 7.48 +/-0.906 0.164 +/-0.906 0.327 pCi/g Radium-226 0.431 +/-0.0859 0.0351 +/-0.0859 0.0702 pCi/g Silver-108m U 0.0126 +/-0.0201 0.0187 +/-0.0201 0.0375 pCi/g Thallium-208 0.135 +/-0.0457 0.0187 +/-0.0457 0.0374 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00758 +/-0.0112 0.0114 +/-0.0112 0.0251 pCi/g BXFI 07/05/06 1218 541208 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B LXMI 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 85 (25°/o- 125%)

16

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-018F Project: YANK01204 Sample ID: 164551002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamima Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

17

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-018FS Proiect: YANK01204 Sample ID: 164551003 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-JUN-06 Receive Date: 08-JUN-06 Collector: Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 0.634 +/-0.206 0.071 +/-0.206 0.142 pCi/g MJHI 06/26/06 2143 538669 1 Americium-241 U 0.0957 +/-0.100 0.064 +/-0.100 0.128 pCi/g Bismuth-212 0.422 +/-0.344 0.163 +/-0.344 0.325 pCi/g Bismuth-214 0.547 +/-0.110 0.0358 +/-0.110 0.0715 pCi/g Cesium-134 U 0.0511 +/-0.0335 0.0264 +/-0.0335 0.0528 pCi/g Cesium-137 0.0955 +/-0.0577 0.0238 +/-0.0577 0.0475 pCi/g Cobalt-60 0.325 +/-0.0637 0.0243 +/-0.0637 0.0486 pCi/g Europium-152 U 0.0356 +/-0.0743 0.0529 +/-0.0743 0.106 pCi/g Europium-154 U - -0.00503 +/-0.0759 0.0633 +/-0.0759 0.127 pCi/g Europium-155 U - -0.00931 +/-0.0655 0.0583 +/-0.0655 0.116 pCi/g Lead-212 0.622 +/-0.0818 0.0315 +/-0.0818 0.063 pCi/g Lead-214 0.491 +/-0.112 0.0375 +/-0.112 0.0749 pCi/g Manganese-54 U - -0.00889 +/-0.0289 0.0208 +/-0.0289 0.0415 pCi/g Niobium-94 U 0.00212 +/-0.0219 0.0194 +/-0.0219 0.0388 pCi/g Potassium-40 9.08 +/- 1.02 0.155 +/-1.02 0.310 pCi/g Radium-226 0.547 +/-0.110 0.0358 +/-0.110 0.0715 pCi/g Silver-108m U - -0.00447 +/-0.0205 0.0176 +/-0.0205 0.0351 pCi/g Thallium-208 0.178 +/-0.0449 0.0192 +/-0.0449 0.0383 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U - 0.00242 +/-0.0123 0.0144 +/-0.0123 0.032 pCi/g BXF1 07/05/06 1218 541208 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B LXMI 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFP( ', Sr90, solid-ALL FSS 63 (25%-/125%)

18

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-018FS Project: YANK0 1204 Sample ID: 164551003 Client ID: YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

19

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6,2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-019F Proiect: YANKO 1204 Sample ID: 164551004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-JUN-06 Receive Date: 08-JUN-06 Collector: Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.578 +1-0.150 0.0742 +/-0.150 0.148 pCi/g MJHI 06/26/06 2144 538669 1 Americium-241 U 0.0776 +/-0.101 0.0852 +/-0.101 0.170 pCi/g Bismuth-212 0.398 +/-0.359 0.182 +/-0.359 0.363 pCi/g Bismnuth-214 0.505 +/-0.106 0.0377 +/-0.106 0.0754 pCi/g Cesium-134 U 0.0291 +/-0.0514 0.0293 +/-0.0514 0.0586 pCi/g Cesium- 137 0.169 +/-0.051 0.0241 +/-0.051 0.0483 pCi/g Cobalt-60 0.121 +/-0.055 0.0149 +/-0.055 0.0297 pCi/g Europium-152 U -0.0386 +/-0.0995 0.057 +/-0.0995 0.114 pCi/g Europium-154 U 0.0464 +/-0.0727 0.0668 +/-0.0727 0.134 pCi/g Europium-155 U 0.0138 +/-0.071 0.0642 +/-0.071 0.128 pCi/g Lead-212 0.678 +/-0.0907 0.0344 +/-0.0907 0.0687 pCi/g Lead-214 0.574 +/-0.134 0.041 +/-0.134 0.0819 pCi/g Manganese-54 U 0.0193 +/-0.0253 0.0237 +/-0.0253 0.0473 pCi/g Niobium-94 U 0.00219 +/-0.0249 0.0213 +/-0.0249 0.0426 pCi/g Potassium-40 9.48 +/-1.13 0.175 +/-1.13 0.350 pCi/g Radium-226 0.505 +/-0.106 0.0377 +/-0.106 0.0754 pCi/g Silver-108m U -0.0117 +/-0.0232 0.0196 +/-0.0232 0.0391 pCi/g Thallium-208 0.223 +/-0.0564 0.0193 +/-0.0564 0.0385 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.0131 +/-0.0146 0.0187 +/-0.0146 0.0406 pCi/g BXFI 07/05/06 1218 541208 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B LXMI 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 65 (25%°-125%)

20

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-019F Project: YANK01204 Sample ID: 164551004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

21

QUALITY CONTROL DATA I

22

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: July 6, 2006 Client: Connecticut Yankee Atomic Power Page 1 of 5 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 164551 Parmname NOM Sample Qual QC Units RPD% REC% Ranee Anlst Date Time Rad Gamma Spec Batch 538669 QC1201113175 164551001 DUP Actinium-228 0.706 0.584 pCi/g 19 (0% - 100%) MJHI 06/28/06 07:02 Uncert: +/-0.172 +/-0.130 TPU: +/-0.172 +/-0.130 Americium-241 U 0.083 U 0.086 pCi/g 4 (0%- 100%)

Uncert: +/-0.0774 +/-0.0902 TPU: +/-0.0774 +/-0.0902 Bismuth-212 0.404 0.381 pCi/g 6 (0%- 100%)

Uncert: +/-0.291 +/-0.154 TPU: +/-0.291 +/-0.154 Bismuth-214 0.570 0.461 pCi/g 21 (0%- 100%)

Uncert: +/-0.101 +/-0.0707 TPU: +/-0.101 +/-0.0707 Cesium- 134 U 0.0448 U 0.0161 pCi/g 94 (0%- 100%)

Uncert: +/-0.0239 +/-0.0236 TPU: +/-0.0239 +/-0.0236 Cesium- 137 0.093 0.128 pCi/g 32 (0%- 100%)

Uncert: +/-0.0318 +/-0.0277 TPU: +/-0.0318 +/-0.0277 Cobalt-60 0.0807 0.0557 pCi/g 37 (0%- 100%)

Uncert: +/-0.0343 +/-0.0288 TPU: +/-0.0343 +/-0.0288 Europium- 152 U -0.0343 U 0.00453 pCi/g 261 (0%- 100%)

Uncert: +/-0.0775 +/-0.0324 TPU: +/-0.0775 +/-0.0324 Europium- 154 U 0.00799 U -0.0244 pCi/g 395 (0%- 100%)

Uncert: +/-0.107 +/-0.0402 TPU: +/-0.107 +/-0.0402 Europium- 155 U -0.0483 U1 0.00 pCi/g 752 (0%- 100%)

Uncert: +/-0.0626 +/-0.0492 TPU: +/-0.0626 +/-0.0492 Lead-212 0.623 0.665 pCi/g 7 (0% - 20%)

Uncert: +/-0.0817 +/-0.073 TPU: +/-0.0817 +/-0.073 Lead-214 0.602 0.566 pCi/g 6 (0% - 20%)

Uncert: +/-0.103 +/-0.0745 TPU: +/-0.103 +/-0.0745 Manganese-54 U 0.00262 U 0.0196 pCi/g 153 (0%- 100%)

Uncert: +/-0.0217 +/-0.0144 TPU: +/-0.0217 +/-0.0144 Niobium-94 U 0.0223 U -0.00792 pCi/g 420 (0%- 100%)

Uncert: +/-0.0208 +/-0.0107 TPU: +/-0.0208 +/-0.0107 23

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164551 Page 2 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 538669 Potassium-40 9.46 9.50 pCi/g 0 (0%-20%)

Uncert: +/-0.987 +/-0.796 TPU: +/-0.987 +/-0.796 Radium-226 0.570 0.461 pCi/g 21 (0%- 100%)

Uncert: +/-0.101 +/-0.0707 TPU: +/-0.101 +/-0.0707 Silver- 108m u -0.00347 U -0.00382 pCi/g 10 (0%- 100%)

Uncert: +/-0.020 +/-0.0103 TPU: +/-0.020 +/-0.0103 Thallium-208 0.212 0.206 pCi/g 3 (0%- 100%)

Uncert: +/-0.0455 +/-0.0277 TPU: +/-0.0455 +/-0.0277 QCI201113176 LCS Actinium-228 U 0.302 pCi/g 06/26/06 21:55 Uncert: +/-0.550 TPU: +/-0.550 Americium-241 23.4 22.8 pCi/g 97 (75%-125%)

Uncert: +/-3.61 TPU: +/-3.61 Bismuth-212 U 0.0874 pCi/g Uncert: +/-1.12 TPU: +/-1.12 Bismuth-214 U 0.180 pCi/g Uncert: +/-0.242 TPU: +/-0.242 Cesium- 134 U -0.0853 pCi/g Uncert: +/-0.152 TPU: +/-0.152 Cesium-137 9.63 9.60 pCi/g 100 (75%-125%)

Uncert: +/-0.746 TPU: +/-0.746 Cobalt-60 14.9 15.7 pCi/g 105 (75%-125%)

Uncert: +/-1.16 TPU: +/-1.16 Europium- 152 U -0.199 pCi/g Uncert: +/-0.337 TPU: +/-0.337 Europium- 154 U 0.0423 pCi/g Uncert: +/-0.316 TPU: +/-0.316 Europium- 155 U -0.129 pCi/g Uncert: +/-0.358 TPU: +/-0.358 Lead-212 U 0.218 pCi/g Uncert: +/-0.190 TPU: +/-0.190 Lead-214 U -0.0377 pCi/g Uncert: +/-0.226 24

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164551 Page 3 of 5 Parmname NOM Samole Oual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 538669 TPU: +/-0.226 Manganese-54 U 0.0251 pCi/g Uncert: +/-0.143 TPU: +/-0.143 Niobium-94 U 0.0304 pCi/g Uncert: +/-0.109 TPU: +/-0.109 Potassium-40 U 0.367 pCi/g Uncert: +/-1.28 TPU: +/-1.28 Radium-226 U 0.180 pCi/g (75%-125%)

Uncert: +/-0.242 TPU: +/-0.242 Silver-108m U 0.120 pCi/g Uncert: +/-0.123 TPU: +/-0.123 Thallium-208 U 0.0113 pCi/g Uncert: +/-0.129 TPU: +/-0.129 QC1201113174 MB Actinium-228 U 0.025 pCi/g 06/28/06 11:28 Uncert: +/-0.0202 TPU: +/-0.0202 Americium-241 U 0.0174 pCi/g Uncert: +/-0.0352 TPU: +/-0.0352 Bismuth-212 U 0.0342 pCi/g Uncert: +/-0.0458 TPU: +/-0.0458 Bismuth-214 U 0.00963 pCi/g Uncert: +/-0.0253 TPU: +/-0.0253 Cesium-134 U -0.00174 pCi/g Uncert: +/-0.00653 TPU: +/-0.00653 Cesium-137 U 0.00514 pCi/g Uncert: +/-0.0129 TPU: +/-0.0129 Cobalt-60 U 0.000786 pCi/g Uncert: +/-0.00617 TPU: +/-0.00617 Europium- 152 U -0.00965 pCi/g Uncert: +/-0.0168 TPU: +/-0.0168 Europium- 154 U -0.00089 pCi/g Uncert: +/-0.017 TPU: +/-0.017 Europium- 155 U -0.00581 pCi/g 25

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164551 Page 4 of 5 Parmname NOM Samolle Oual OC Units RPD% REC% Ranee Anist Date Time Rad Gamma Spec Batch 538669 Uncert: +/-0.0148 TPU: +/-0.0148 Lead-212 UI 0.00 pCi/g Uncert: +/-0.0103 TPU: +/-0.0103 Lead-214 U 0.0144 pCi/g Uncert: +/-0.0117 TPU: +/-0.0117 Manganese-54 U -0.00313 pCi/g Uncert: +/-0.00578 TPU: +/-0.00578 Niobium-94 U 0.00179 pCi/g Uncert: +/-0.00587 TPU: +/-0.00587 Potassium-40 UT 0.00 pCi/g Uncert: +/-0.0746 TPU: +/-0.0746 Radium-226 U 0.00963 pCi/g Uncert: +/-0.0253 TPU: +/-0.0253 Silver-108m U 0.00355 pCi/g Uncert: +/-0.00525 TPU: +/-0.00525 Thallium-208 U 0.00341 pCi/g Uncert: +/-0.0157 TPU: +/-0.0157 Rad Gas Flow Batch 541208 QC 1201119318 164551004 DUP Strontium-90 U -0.0131 U -0.0114 pCi/g 0 (0%- 100%) BXFI 07/05/06 12:18 Uncert: +/-0.0146 +/-0.0131 TPU: +/-0.0146 +/-0.0131 QC1201119320 LCS Strontium-90 1.38 1.27 pCi/g 92 (75%-125%) 07/05/06 14:24 Uncert: +/-0.0859 TPU: +/-0.0943 QC1201119317 MB Strontium-90 U 0.00252 pCi/g 07/05/06 12:18 Uncert: +/-0.0114 TPU: +/-0.0114 QC1201119319 164551004 MS Strontium-90 2.55 U -0.0131 2.38 pCi/g 93 (75%-125%) 07/05/06 14:25 Uncert: +/-0.0146 +/-0.153 TPU: +/-0.0146 +/-0.169 Notes:

The Qualifiers in this report are defined as follows:

26

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 164551 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

27

Table of Contents G eneral Narrative .................................................................. 1 Chain of Custody and Supporting Documentation ........... 4 Radiological Analysis .......................................................... 11 Sample Data Summary ...................................................... 16 Q uality C ontrol D ata ........................................................... 20

General Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 167358 SDG: MSR #06-0755 July 25, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on June 02, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 167358001 9106-0002-014FS Items of Note:

Based on an email received on July 19, 2006, GEL mistakenly canceled the analyses requested for sample 9106-0002-014FS in the original work order 164220. Upon notification by CYAPCO and subsequent clarification emails, GEL relogged sample 9106-0002-014FS for the requested analyses under work order 167358.

2

Analytical Request:

One sediment samples was analyzed for FSSGAM and Sr-90.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712 - Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171 - Fa&843) 766-1178

  • www.gel.com

Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Maj or Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00372 362 Injun Hollow Road. East Hampton, CT 06424 860-267-2556

_roject Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only

-ontact Name & Phone: Comments:

rack McCarthy 860-267-2556 Ext. 3024

-nalytical Lab (Name, City, State) 3eneral Engineering Laboratories Z040 Savage Road. Charleston SC. 29407 343 556 8171. Attn. Cheryl Jones Ln C

?riority: Z 30 D. [] 14 D. [E 7 D. Container Sample Size-Media Type &Type Sazwple Designation Date Time Code Code Code Comment, Preservation Lab Sample ID

)106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364

)106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 106-0002-011F 5/19106 08:10 SE C BP X X Transferred from COC 2006-00365

)106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365

)106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365

?106-0002-014F 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365

)106-0002-014FSt, 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365

)106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365

)106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 WOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA fl Non QA Samples Shipped Via: Internal 0 '755 Z Fed Ex Container 4t 1 o.'aY, i0/k/ UPS Da C Temp.:

4 eYb

_Mcvv+ tLaCE L Hand Custody I DyL Sealed?

  • Relin u~he Date/Time .. 2) Reived By DatjýTime Custody Seal

, /% "- C4(,. [J Other Intact?

1)'1elinquished By Date/Time 4) ReceivedBy Date/Time 'Y.___"0_.___ Y-.N N-

_*_.__ .___ _ Bill of Lading #

) Relinquished By Date/Time 6) Received By Date/Time 7O 7// &

  • t

Connect~cut Yankee.

_ ' .. " CY-iSC-Sow-001 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List.

Date/Time pRectivedz, 0 (-

SDG#:

Work Order Number_ (LP.

Cut3qd,'hipinC .

Shipping Custainer 1 Custody Seats orshipping container intact? "Yes No Yes N.o .

2. Custody Seals dated and signed?
3. Chain-of-Custo,,y record present? Ye

'~s/ No [ ]

  • 4. Cooler emperature
5. Vermiculite/packing materials is: Wet [ Dry',t 0 *pC"C(4

" -.-

6.' Number of samples in shipping container:

Y No

7. Sample. holding times exceeded?
8. S I hav""

ý]L ap zr labels

-- h-a".

.custody seal*s " -appropriate sample labels

9. Sarmples are.

good condition . l....eaking'

-broken -*.....have air bubbles Yes [No "j

10. Were any anomalies identified in sample receipt? . 9
  • .....Description of anomalies (include sample numbers): _ _"_._,

Sample Custodian/Laboratory:.

S 4.0Dt'  :

On By .

Telephoned to: .-. *""". B -

."~~~- "'

  • SAMPLE RECEIPT & REVIEW FORM

%,.*,,*S "PM use only

., ,J n - /" Y C r c(4c

,Client: YA RG C- SDGIARCOC-Work Order: (OZO Date Received: (,a C$ýo PM(A) Review (ere non-ýconfo ng i rns are resolved prior to signing); j Received By:j Sample Receipt Criteria Comments/Qualitiers / quired for Non-Conforming Items) other (describe)

Circle Applicable: seals broken/ damaged container leaking container Shipping containers received intact I and sealed? I /_._ _

Circle Coolant # ice'bags blue ice dry ice none other describe)

Samples requiring cold 2 preservation within (4 +/- 2 C)? //

Record preservation method. /_/

Chain of custody documents included with shipment?

Circlpplicable: seals broken damaged container leaking container other (describe) 4 Sample containers intact and sealed?

Samples requiring chemical Sample UD's. containers affected and observed pH:

preservation at proper pH?

VOA vials free of headspace Sample ID's and containers affected:

6 (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laborator) ,_ ,_,

8 Samples received within holdin ýl's and tests affected:

time?

9 Sample ID's on COC matc ID's Sample ID's and containers affected:

on bottles? /_

tch date Sample ID's affected:

10 Date & time on COC

&time on bottles? _/

Number of container received Sample ID's affected:

match number indic/ted on COC?

COC form is propirly signed in  : "-

1relinquished/received sections? cCc-- Zo -02(-

1 Air Bill ,Tracking #'s,

&

Additional Comments V TRSO RAD Receipt # ____________

e 3 *If > x2 area background is observed on samples identified as "non-p Hr ._ regulated/non-radioactive", contact the Radiation Safety group for further

__ __ __ L__ investigation.

A [Radiological Classification? Maximum Counts Observed*: '

B [PCB Regulated? Comments:

Shipped as DOT Hazardous C jMaterial? If yes, contact Waste / Hazard Class Shipped:

]Manager or ESH Manager. / ON#:

PM (or PMA) review of Hazard classiftication: Initials -Date: -Zj U

RE: Missing sample results from GEL (MSR #06-0755)

Subject:

RE: Missing sample results from GEL (MSR #06-0755)

From: "Dale Randall" <randall@cyapco.com>

Date: Wed, 19 Jul 2006 09:22:51 -0400 To: "Cheryl Jones" <cj@gel.com>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@ CYAPCO.com>

Cheryl, We would appreciate a short narrative of the corrections for 164220 and an expedited analysis of sample 9106-0002-014S. Thanks for your prompt attention in helping us resolve this issue.

Best Regards, Dale


Original Message -----

From: Cheryl Jones [mailto:cj@gel.coml Sent: Wednesday, July 19, 2006 9:07 AM To: Dale Randall Cc: Clyde Newson; John McCarthy

Subject:

Re: Missing sample results from GEL (MSR #06-0755)

Dale, It appears that the direction in Jack's original email was misunderstood. Talking this situation over with Cheryl Duffy, it's clear that we took his direction to 'withdraw and exclude samples 1, 3, 6, and 16 from analysis' to be our sample IDs and not the location IDs from the COC. In this case, we should have requested clarification and I apologize that we did not. We have the sample container for 9106-0002-014FS and will relog it today for the requested analyses. Do you need these results expedited?

Also, will you need the narrative for 164220 corrected to reflect the requested cancellation email?

Thanks, Cheryl Dale Randall wrote:

I You are correct. My notes also indicate that due to a design change, we intended to stop analysis for samples 9106-0002-001F, 9106-0002-003F, 9106-0002-006F, 9106-0002-006FS, and 9106-0002-016F. (Before seeing your notes I was a little confused as to why we have a result for 9106-0002-006FS but not 9106-0002-006F) In any case, that leaves the result for sample 9106-0002-014FS as missing. Could this sample result be provided?


Original Message -----

From: Cheryl Jones (mailto:cj@gel.com]

Sent: Wednesday, July 19, 2006 8:30 AM To: John McCarthy Cc: Dale Randall; Clyde Newson; Cheryl Duffy

Subject:

Re: Missing sample results from GEL (MSR #06-0755)

Jack, The documentation in the package is incomplete. The COC has a note written on the bottom indicating that the analyses were canceled for several samples at the request of an email received on 6/5/06. The email should have also been included in the package to document the request and this information should have been listed in the Items of I of 3 8 7I/2.51065I PMLOD;U I

RE: Missing sample results from GEL (MSR #06-0755)

I Note section of the package general narrative. I've attached the email I

request for your use. Do you need me to correct the package narrative and resend it?

Thanks, Cheryl John McCarthy wrote:

Cheryl, could you follow up on this?

Thank you Jack

  • From:* Dale Randall
  • Sent:* Wednesday, July 19, 2006 7:53 AM
  • To:* John McCarthy; Clyde Newson

Subject:

  • Missing sample results from GEL (MSR #06-0755)

Jack:

MSR #06-0755 does not contain results for samples 9106-0002-006F or 9106-0002-014FS. We have documentation indicating that the listed samples were received by GEL, but they were not included with results package (either in hardcopy or electronically). Please query the lab as to their status.

Thanks, Dale P.S. Each of these samples is one half of a split, which would be a problem except that we collected an additional split in the second round of sampling. We thus meet the 5% spilt-sample requirement.

Bottom line: we comply with the FSS requirements, but less justification will be needed if we receive the two sample results that 2 of 3 9 7/25/2006 5:04 PM

RE: Missing sample results from GEL (MSR #06-0755) are missing.

Cheryl A. Jones Project Manager/PM Team Leader General Engineering Laboratories, LLC 2040 Savage Road Charleston, S.C. 29407 (843) 769-7388 Direct Line (843) 556-8171 x 4243 (843) 766-1178 (fax)

The information contained in this message is confidential and is intended only for the use of the individual or firm of record. If you are not the intended recipient and have received this message in error, you are asked not to copy or distribute any of the pages that follow. Please notify the sender immediately by telephone or email if you have received this communication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.

3 of 3 10 7/25/2006 5:04 PM

RADIOLOGICAL ANALYSIS 11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 167358 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 549751 Prep Batch Number: 549528 Sample ID Client ID 167358001 9106-0002-014FS 1201139316 Method Blank (MB) 1201139317 167358001(9106-0002-014FS) Sample Duplicate (DUP) 1201139318 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 167358001 (9106-0002-014FS).

12

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201139317 (9106-0002-014FS) and 167358001 (9106-0002-014FS) were recounted due to high relative percent difference/relative error ratio.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample Data rejected due to a high full-width, half UI Bismuth-212 167358001 maximum.

UI Data rejected due to low abundance Actinium-228 1201139316 Bismuth-214 1201139316 Lead-212 1201139316 Lead-214 1201139316 Potassium-40 1201139316 Radium-226 1201139316 Method/Analysis Information 13

Product: GFPC, Sr9O, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 549724 Prep Batch Number: 549529 Dry Soil Prep GL-RAD-A-021 Batch Number: 549528 Sample ID Client ID 167358001 9106-0002-014FS 1201139231 Method Blank (MB) 1201139232 167358001(9106-0002-014FS) Sample Duplicate (DUP) 1201139233 167358001(9106-0002-014FS) Matrix Spike (MS) 1201139234 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 167358001 (9106-0002-014FS).

QC Information All of the QC samples met the required acceptance limits.

14

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

15

SAMPLE DATA

SUMMARY

16

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO 1 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-0755 GEL Work Order: 167358 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

by Reviewed 17

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 26, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-014FS Project: YANKO 1204 Sample ID: 167358001 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 10.6%

Parameter (*ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.681 +/-0.193 0.0749 +/-0.193 0.164 pCi/g MJH 1 07/25/06 1656 549751 1 Americium-241 U -0.0046 +/-0.0284 0.0258 +/-0.0284 0.0536 pCi/g Bismuth-212 UI 0.00 +/-0.385 0.155 +/-0.385 0.339 pCi/g Bismuth-214 0.502 +/-0.102 0.0358 +/-0.102 0.0773 pCi/g Cesium-134 U 0.056 +/-0.041 0.0286 +/-0.041 0.0614 pCi/g Cesium-137 U 0.0113 +/-0.0248 0.0224 +/-0.0248 0.048 pCi/g Cobalt-60 U -0.00841 +/-0.025 0.0198 +/-0.025 0.045 pCi/g Europium- 152 U -0.00306 +/-0.0528 0.0454 +/-0.0528 0.0969 pCi/g Europium-154 U 0.018 +/-0.0721 0.0629 +/-0.0721 0.140 pCi/g Europium-155 U 0.0395 +/-0.0502 0.0458 +/-0.0502 0.0954 pCi/g Lead-212 0.744 +/-0.0662 0.0285 +/-0.0662 0.0599 pCi/g Lead-214 0.570 +/-0.100 0.0325 +/-0.100 0.0695 pCi/g Manganese-54 U 0.00657 +/-0.0265 0.0229 +/-0.0265 0.0498 pCi/g Niobium-94 U 0.000605 +/-0.0206 0.0177 +/-0.0206 0.0383 pCi/g Potassium-40 10.9 +/-1.08 0.152 +/-1.08 0.358 pCi/g Radium-226 0.502 +/-0.102 0.0358 +/-0.102 0.0773 pCi/g Silver-108m U 0.00362 +/-0.0184 0.0169 +/-0.0184 0.0362 pCi/g Thallium-208 0.241 +/-0.0493 0.0193 +/-0.0493 0.0418 pCi/g Rad Gas Flow Proportional Counting GFPC,S90, solid-ALL FSS Strontium-90 U -0.007 +/-0.0145 0.0143 +/-0.0145 0.0302 pCi/g BXF1 07/24/06 1727 549724 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/19/06 1817 549528 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 18

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 26, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-014FS Proiect: YANK0 1204 Sample ID: 167358001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits CarrierfIracer Recovery GFPC, Sr90, solid-ALL FSS 57 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

19

I QUALITY CONTROL DATA 20

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: July 26, 2006 Client: Connecticut Yankee Atomic Power Page 1 of 5 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 167358 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 549751 QC1201139317 167358001 DUP Actinium-228 0.681 0.688 pCi/g I (0%- 100%) MJH1 07/25/06 16:57 Uncert: +/-0.193 +/-0.228 TPU: +/-0.193 +/-0.228 Americium-241 U -0.0046 U 0.0036 pCi/g 1630 (0%- 100%)

Uncert: +/-0.0284 +/-0.0415 TPU: +/-0.0284 +/-0.0415 Bismuth-212 UI 0.00 U 0.329 pCi/g 67 (0% - 100%)

Uncert: +/-0.385 +/-0.419 TPU: +/-0.385 +/-0.419 Bismuth-214 0.502 0.494 pCi/g 2 (0%- 100%)

Uncert: +/-0.102 +/-0.154 TPU: +/-0.102 +/-0.154 Cesium- 134 U 0.056 U -0.00194 pCi/g 214 (0%- 100%)

Uncert: +/-0.041 +/-0.0372 TPU: +/-0.041 +/-0.0372 Cesium- 137 U 0.0113 U 0.0259 pCi/g 78 (0%- 100%)

Uncert: +/-0.0248 +/-0.0314 TPU: +/-0.0248 +/-0.0314 Cobalt-60 U -0.00841 U 0.000847 pCi/g 245 (0% - 100%)

Uncert: +/-0.025 +/-0.0418 TPU: +/-0.025 +/-0.0418 Europium- 152 U -0.00306 U -0.04 pCi/g 172 (0% - 100%)

Uncert: +/-0.0528 +/-0.0664 TPU: +/-0.0528 +/-0.0664 Europium- 154 U 0.018 U -0.00385 pCi/g 309 (0%- 100%)

Uncert: +/-0.0721 +/-0.0955 TPU: +/-0.0721 +/-0.0955 Europium- 155 U 0.0395 U 0.0162 pCi/g 84 (0%- 100%)

Uncert: +/-0.0502 +/-0.0627 TPU: +/-0.0502 +/-0.0627 Lead-212 0.744 0.702 pCi/g 6 (0% - 20%)

Uncert: +/-0.0662 +/-0.081 TPU: +/-0.0662 +/-0.081 Lead-214 0.570 0.625 pCi/g 9 (0%- 20%)

Uncert: +/-0.100 +/-0.107 TPU: +/-0.100 +/-0.107 Manganese-54 U 0.00657 U 0.00559 pCi/g 16 (0% - 100%)

Uncert: +/-0.0265 +/-0.032 TPU: +/-0.0265 +/-0.032 Niobium-94 U 0.000605 U 0.014 pCi/g 183 (0%- 100%)

Uncert: +/-0.0206 +/-0.0266 TPU: +/-0.0206 +/-0.0266 21

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder: 167358 Page 2 of 5 Parmname NOM Samnle Oual QC Units RPD% REC% Range Anlst Date Time 5

Summary Page 2 of Rad Gamma Spec QC Batch 549751 Potassium-40 10.9 9.58 pCi/g 13 (0% - 20%)

Uncert: +/-1.08 +/-1.11 TPU: +/-1.08 +/-1.11 Radium-226 0.502 0.494 pCi/g 2 (0%- 100%)

Uncert: +/-0.102 +/-0.154 TPU: +/-0.102 +/-0.154 Silver-108m u 0.00362 U 0.00577 pCi/g 46 (0%- 100%)

Uncert: +/-0.0184 +/-0.0235 TPU: +/-0.0184 +/-0.0235 Thallium-208 0.241 0.227 pCi/g 6 (0%- 100%)

Uncert: +/-0.0493 +/-0.064 TPU: +/-0.0493 +/-0.064 QCI201139318 LCS Actinium-228 U -0.0826 pCi/g 07/23/06 23:03 Uncert: +/-0.366 TPU: +/-0.366 Americium-241 23.4 25.8 pCi/g 110 (75%-125%)

Uncert: +/-2.13 TPU: +/-2.13 Bismuth-212 U -0.368 pCi/g Uncert: +/-0.777 TPU: +/-0.777 Bismuth-214 U 0.117 pCi/g Uncert: +/-0.178 TPU: +/-0.178 Cesium-134 U -0.0432 pCi/g Uncert: +/-0.0954 TPU: +/-0.0954 Cesium-137 9.60 10.2 pCi/g 106 (75%-125%)

Uncert: +/-0.911 TPU: +/-0.911 Cobalt-60 14.7 15.0 pCi/g 102 (75%-125%)

Uncert: +/-0.935 TPU: +/-0.935 Europium- 152 U -0.0642 pCi/g Uncert: +/-0.217 TPU: +/-0.217 Europium-154 U 0.142 pCi/g Uncert: +/-0.202 TPU: +/-0.202 Europium-155 U -0.0245 pCi/g Uncert: +/-0.304 TPU: +/-0.304 Lead-212 U 0.056 pCi/g Uncert: .+/-0.136 TPU: +/-0.136 Lead-214 U 0.0714 pCi/g Uncert: +/-0.154 22

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 167358 Page 3 of 5 Parmname NOM Samole Oual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 549751 TPU: +/-0.154 Manganese-54 U -0.0352 pCi/g Uncert: +/-0.0898 TPU: +/-0.0898 Niobium-94 U 0.0196 pCi/g Uncert: +/-0.0827 TPU: +/-0.0827 Potassium-40 U -0.0266 pCi/g Uncert: +/-0.757 TPU: +/-0.757 Radium-226 U 0.117 pCi/g (75%-125%)

Uncert: +/-0.178 TPU: +/-0.178 Silver- 108m U -0.0296 pCi/g Uneert: +/-0.0823 TPU: +/-0.0823 Thallium-208 U 0.0283 pCi/g Uncert: +/-0.0898 TPU: +/-0.0898 QCI201139316 MB Actinium-228 UI 0.00 pCi/g 07/23/06 23:02 Uncert: +/-0.0206 TPU: +/-0.0206 Americium-241 U 0.000573 pCi/g Uncert: +/-0.0291 TPU: +/-0.0291 Bismuth-212 U 0.0249 pCi/g Uncert: +/-0.0402 TPU: +/-0.0402 Bismuth-214 UI 0.00 pCi/g Uncert: +/-0.012 TPU: +/-0.012 Cesium-134 U 0.00736 pCi/g Uncert: +/-0.00599 TPU: +/-0.00599 Cesium- 137 U 0.000658 pCi/g Uncert: +/-0.0128 TPU: +/-0.0128 Cobalt-60 U 0.00664 pCi/g Uncert: +/-0.00569 TPU: +/-0.00569 Europium- 152 U 0.00871 pCi/g Uncert: +/-0.0124 TPU: +/-0.0124 Europium- 154 U 0.00596 pCi/g Uncert: +/-0.0157 TPU: +/-0.0157 Europium- 155 U 0.00413 pCi/g 23

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 167358 Page 4 of 5 Parmname NOM Sample Oual OC Units RPD% REC% Ranee Anist Date Time Rad Gamma Spec Batch 549751 Uncert: +/-0.0126 TPU: +/-0.0126 Lead-212 UI 0.00 pCi/g Uncert: +/-0.0091 TPU: +/-0.0091 Lead-214 UI 0.00 pCi/g Uncert: +/-0.0108 TPU: +/-0.0108 Manganese-54 U -0.000149 pCi/g Uncert: +/-0.00597 TPU: +/-0.00597 Niobium-94 U 0.00445 pCi/g Uncert: +/-0.00562 TPU: +/-0.00562 Potassiurn-40 UI 0.00 pCi/g Uncert: +/-0.0645 TPU: +/-0.0645 Radium-226 UI 0.00 pCi/g Uncert: +/-0.012 TPU: +/-0.012 Silver-108m U 0.00402 pCi/g Uncert: +/-0.00406 TPU: +/-0.00406 Thallium-208 U 0.00908 pCi/g Uncert: +/-0.0056 TPU: +/-0.0056 Rad Gas Flow Batch 549724 QC1201139232 167358001 DUP Strontium-90 U -0.007 U 0.00548 pCi/g 0 (0% - 100%) BXFI 07/24/06 17:27 Uncert: +/-0.0145 +/-0.0205 TPU: +/-0.0145 +/-0.0205 QC1201139234 LCS Strontium-90 1.42 1.14 pCi/g 81 (75%-125%) 07/24/06 17:27 Uncert: +/-0.0482 TPU: +/-0.0591 QC1201139231 MB Strontium-90 U 0.0153 pCi/g Uncert: +/-0.0164 TPU: +/-0.0165 QC1201139233 167358001 MS Strontium-90 1.42 U -0.007 1.37 pCi/g 96 (75%-125%) 07/24/06 17:27 Uncert: +/-0.0145 +/-0.0748 TPU: +/-0.0145 +/-0.082 Notes:

The Qualifiers in this report are defined as follows:

24

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 167358 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

25

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. Box 30712 - Charleston, SC 29417

  • 2040 Savage Road (29407)

Page 2 of 105 Phone (843) 556-8171 *Fax (843) 766-1178

  • www.gel.com

168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F Items of Note:

At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Seven soil samples were reanalyzed for FSSALL., except gamma and Sr-90.

Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.

Two soil samples were reanalyzed for FSSALL, except gamma.

Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

PO. Box 30712

  • Charleston, SC 29417 ° 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105

. Iý

Additional HTD analyses

Subject:

Additional HTD analyses I (.p 8,LI oqI, (I From: "Dale Randall" <randall@cyapco.com>

Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj @gel.corn>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@ CYAPCO.com>

Cheryl:

Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol. I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description: GEL FSSALL analyses request.xls GEL FSSALL analyses request.xls i Content-Type: application/vnd.ms-excel Content-Encoding: base64 IloflI Page 4 of 105 8/2/2006 7:04 PM

flnne Tn be done Done To be done Previous GEL ID ICY samnie location IDs FSS Gain Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 C164220008 9106-0002-007F x x x x x x x x x x o 164220012 9106-0002-011F x _ x x x x x x x x x 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832001 9106-0004-015F x x x x x x x x x x 162485001 9106-0005-010F x x x x x x x x x x 162485011 162850014 9106-0005-014F x x x x x x x x x x x 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 91060010-001 F x x x x x x x x x x 163105016 9106-0010-012F x x x x x x x x x x

Chain of Custody and Supporting Documentation Page 6 of 105

kvlaj ffe !K 1)1ý Iq Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-001 Major Chain of Custody NoForm007 Connecticut Yankee Atomic Power Company No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556 .....

cProject Name: Haddarn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 a 843 556 8171. Attn. Cheryl Jones C U ,

1 40 .A Priority: Z 30 D. [] 14 D. [-] 7 D. Container Sample Size- ,_ _

Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OO1F 5/17/06 10:42 SE C BP x x Transferred from COC 2006-0o357 9106-0002-002F 5/18/06 09:43 SE C BP x Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP x x Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP x x Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x -'Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X X _ _ Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x x Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP x x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 114:04 SE C BP "x x Transferred from COC 2006-00364 NOTES: P0 #: 002332 MSR #: 06- SSWP# NA [K LTP QA El Radwaste QA E3 Non QA Samples Shipped Via: Internal r5 Fed Ex Container El UPS Temp.:

Deg. C fl Hand Custody Sealed?

IRehi - Date/Time 2) 1ý ived By Date/Time Custody Seal e-& -- "ý4 ( C\'.;O EOthler Intact?

ýýIelinquished B Date/Time 4) Received By Date/Time BillofLading ___Y 11 NO Bill of Lading R

5) Relinquished By Date/Time 6) Received By Date/Time I 17J I 5.*7/C

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Healt Phyics roceure PP-GGR-R 10-0 AtahetBCY0 a CD Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00372 00 362 Injun Hollow Road, East Hampton, CT 06424 5 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name &Phone: 'Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

  • General Engineeriag Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones rn Priority: S] 30 D.[1 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation 9106-0002-009F Date 5/18/06 Time Code Code Code 14:28 SE C BP XTrsfrefomC Comment, Preservation Tr-n-e-e- Lab Sample I2 9106-0002-00F 5/18/06 14:50 SE C BP X X 20-06 Transferred from COC 2006-00364 9106-0002-01IF 5/19/06 08:10 SE C BP x x -Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X X Transferred frorn-COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X - Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:89 SE C BP x X - Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 NOTES: PO # 002332 MSR #: 06- SSWP# NA Z LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal

, Fed Ex Container 0 UPS Temp.: __

Deg. C LI Hand Custody Sealed?

1 Relin ish Date/Time 2) Re ived By Dat*T ime Custody Seal COther Intact?

3)"Kelinquished By Date/Time 4) Received By Date/Time _ _ _ _ NO Bill of Lading I

5) Relinquished By Date/Time 6) Received By Date/Time 7qo0 J c

Connecticut Yankee Statement of Work for Analytical Lab Services -CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received: (0 "? . ( g *o SDG#: c)- 0 -C -"

Work Order Number: LL17z( ".

Shipping C , ,tainer IDT, 196_5S /O Chain of Custody*# ,,* '() 4, c .') /

1. Custody Seals oti shipping container intact?., Yes No[]
2. Custody Seals dated and signed? Yes No[]
3. Chain-of-Custody record present? Yes No []

.4. Cooler temperature "

5. Verniculite/packing materials is: Wet [ Dry [A 0] (0

.Number of samples in shipping container: _ _ __.'_"_"_

7. Sample holding times exceeded? Yes[] No
8. Samples have:

tape _ hazard labels

_-_ custody seals __ appropriate sample labels

9. Samples arei

..__ ifl good condition -_leaking

-broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes[, NoX
11. Description ofanomalies (include sample numbers):

Saample Custodian/Laboratory: Datez - - (--

Telephoned to: On*By -

Page 9 of 105

Connecticut Yankee

-CY-ISC-SOW-O01 Statement of Work for Analytical Lab Services Figure I. Sample Check-in List Datedrime Received, "~ t SDG#: A-5 o(

Work Order Number:n -OcA' I.

Shipping Cdntainer ID.p_ _5720T Chain of Custody#_J)j ( vc'37" S1. Custody Seals oti shipping container intact?.. -Yes No []

2. Custody Seals dated and signed? Yes No [ ].
3. Chain-of-Custody record pre.sent?
  • Yes Not]

.4. Cooler tQmprature.

5. Vermiculite/packing materials is: 'Wet [ Dry ~Ji*

~A.u~'e~f 6.: Number of samples in shipping container: _ _ _ _ _ "

7. Sample holding times exceeded? . Yes []No

.8. tshave-:.

ae____hazard labels custody seals -appropriate sample labels

9. Samples are:

_4 ingood condition leaking bbmken ---- have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ ] No
11. .. Description of anomalies (include sample numbers):

Sample. Custod.ian/Laboratory: 4(;1- y-Date:

Telephoned to:* ___By.

Page 10 f;105.

LEN%

SAMPLE RECEIPT & REVIEW FORM PM use only I (A(220 Cient:( *o*4f l , , P **e---. SDG/ARCOC/Work Order:

IDate ReceivedReceived:

By: &R aGIj QPM(A) J Review (eisure non-conforming items are resolved prior to signing);

Sample Receipt Criteria CommentslQualifiers (Required for Non-Conforming Items) container offir (describe)

Applicable: seals broken damaged cnaerI I ýShipping containers received intactl >.1Circle, and sealed? 7 Circle Coolant # ice bags blue ice dry ice none other describe)

Samples requiring cold 2 preservation within (4 +1!-2 C)?

-Record preservation method.

3.Chain of custody documents intactand__,___/___

included with shipment?

intact and ite Applicable: sdSbroken damaged container leaking container other (descrile)

S ample containers 4 sealed? I I Samples requiring chemical Spap 'IDs.

containers affected and observed pH:

preservation atproperpH?

VOA vials free of headspace (defined as < 6mm bubble)?

Z Sample ID's and containers affected: l Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received wi holding Id's and tests affected:

time? /

SSample ID's OC match ID's Sample ID's and cornainers affected:

on bottles?

1-Date& on COC match date "ample IS affected!

& ti on bottles?

Nu ber of containers received Sample IU's affected:

match number indicated on COC?

signed in COC form is properlysections?

12rlnusc/reccived 4~*! O*-(Oo"(

14Air Bill ,Tracking#13 &

Additional Comments e RSORAD Receipt #

Suspected Hazard Information . ' = *If > x2 area background is observed on samples identified as "non-Z regulated/non-radioactive,, contact the Radiation Safety group for further Sinvestigation.

A Ra c a Us.a Maximum Counts Observed*:

Pag Haardusa of ents:

asDOT' hippd cMaterial?It"yes, contact Waste Haad Class Shipped:

---.

Manager or ESH Manager. J N#:

Inin""irtials PM (or PMA) review of Hazard ]lass Page I11 of 105 (0G

SAMPLE ]RECEIPT & REVIEW FORM 0" PMus ol SClient: YZ -nre C_ [SDGIARCOC1W~k Order:_ &. 4'ZZOprotosrn:

c 0 C)v PM(A) Review ( e non-confor

  • areg esovd ior to signing):

Date Received:

Received By: MI Sample Receipt Criteria  ; z Comments/Qualifiers equired for Non-Conforming Items)

Applicable: seals broke damnaged container leaking container other (des.cribe) 1 and containers received intact sealed?

Shipping Circle

__ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _

Samples requiring cold Circle Coolant # icyfags blue ice dry ice none other describe) preservation within (4 +/- 2 C)?

Record preservation method.

Chain of custody documents included with shipment?

licable: seals broken damaged container leaking container otier (describe)

Sample containers intact and Cr sealed?

5 Samples requiring chemical Sampe ID's. containers affected and observed pH:

preservation at proper pH?

Sample 1D's and containers affected:

6 VOA vials free of headspace (defined as < 6mm bubble)? .....

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) _ ,I,_,

Samples received within hold* id's and ,ests affected, time?

9 Sample ID's on COC matc ID's Sample ID's and containers affected:

on bottles? /

Date & time on COC tch date Sample ID's affected:

&time on bottles? _

Number of containe received Sample ID's affected:

match number indic-ted on COC?

COC form is propirly signed in .4-'

1relinuished/rEgived sections? CoC* Z-0C)p oal' -t- 1(4.

Air Bill ,Tracking #'s, &

Additional Comments W- RSORAD Receipt # ___________

d Ht - *I > x2 area background is observed on samples identified as -non-Suspected _ regulated/non-radioactive", contact the Radiation Safety group for further

_ __* investigation.

A Radiological Classification? , Maximum Counts Observed*: , - ,/n SPCB Regulated? Comments:

Shipped as D)01 HazardJous-c Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. UN#:

PM (or PMA) review of Hazard classification: Initials -g(-7A 0(o Page 12 of 105 U

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major

~Chain of Custody Form No. 2006-00312 Connecticut Yankee Atomic Power Company

2. ~362 Injun H-ollow Road, East Hampton, CT 06424/

860-267-2556 UL1,j4 /&,2335 5/4/ '0 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only.-

- Contact Name & Phone: IComents:

Jack McCarthy 860-267-2556 Ext, 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories <

  • 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn Priority: 0 30 D.E[] 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample.ID-9106-0003-OO1F 4/24/06 14:13 SE C BP X Transferred from COC2006-00221 il' 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221 p) 9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223 9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223 9106-0003-007F 4/25/06 10:28 SE C BP X "transferredfrom COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP X Transferred from COC2006-00223 NOTES: PO #: 002332 MSR #: 06- , SSWP# NA Z LTP QA El Radwaste QA C1 Non QA Samples Shipped Via: .. nterna,CoQpht~r.er Combined sampies 9106-0003-003F taken on 4/25/06 @09:19 and 9106-0003-003FB taken on 4025/06@ 08:19 in order to have sufficient sample for counting. EE] Fed U PS Ex !Tetpi*..:::
.::;:**",.

'..DegeC

.' .. ,.":

0I Hand Custody Sealed9 .

1)Relinquished By Date/Time 2) - ived By t ie*isoySa nat

/-______________.__,_y_--______.330

,

_

f1 Other

3) Relinquished By Date/Time 4) Received By Da/Time _______________Y :l N -

Bill of Lading .

5) Relinquished By Date/Time 6) Received By Date/Time . 92O- 9,,O-O2 4 "

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-00313 Connecticut Yankee Atomic Power Company (r

362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 - ,

-Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: r Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) .. .

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 ...

843 556 8171. Attn. Cheryl Jones Priority: Z 30 D.[ 14 D. 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code -- 7Comment, Preservation -. ,,. ..

toAi 9106-0003-009F 4/25/06 13:00 SE C BP X Transferred from COC 2006-00236 '. ..

0A 9106-0003-010F 4/25/06 13:23 SE C BP X -

TransferredfromCOC2006-00236 4/25/06 13:23 SE C BP x Transferred from COC 2006-00236 0 9106-0003-O1OFS 9106-0003-012F 4/25/06 15:12 SE C BP x Transferred from COC 2006-00236 S9106-0003-012F 4/25/06 14:121 SE C BP x- - Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP X Transferred from COC 2006-00236 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred from COC 2006-00236 SE C BP X Transferred from COC 2006-00237 OR 9106-0003-015F 4/26/06 08:16 9106-0003-017F 4/26/06 09:18 SE C BP x Transferred from COC 2006-00237

-9106-0003-018F 4/26/06 08:59 SE C BP X Transferred from COC 2006-00237 .J "'Y. ,

NOTES: PO #: 002332 MSR #: 06- Os SSWP#NA 0 LTP QA Samples Shipped Via:

[I Radwaste QA [] Non QA Z Fed Ex ..T~eer 4De C El uPs !N' El Hand yso 6Jd?

1) Relinquished By Date/Time 2) fReceived By Date//Time D . b'td~

El Other _J;

3) Relinquished By Date/Time 4) Received By rDaC/Time I;Y-t~4N Bill of Lading #

75120-Z'1-20/- o2,d

ux,." /

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received: t (.0I SDG#: j46j '

Work Order Number: . I tceZ-3 Shipping cdntainer ID: "-l wqlf

'zi ) 0_7Ci f IChain of Custody# a* ( )(Yo 003'i

1. Custody Seals off shipping container intact?. Yes t ] No
2. Custody Seals dated and signed7 Yes ' [ No
3. Chain-of-Custody record present? Yes No []

.4. Cooler temperature CI1 C.-

5. Vermiculite/packing materials is: 'et [ Dry [ n]

'__-_!__:_

6.' Number of samples in shipping container: [t e- 7 Ea r'-t[ ri L

7. Sample holding times exceeded? Yes [ I No

.8. Sampleh  :'

tae -hazard labels

  • custody seals -appropriate sample labels
9. Samples are-good condition jleaking

-broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ ] No I.. =Description of anomalies (include sample numbers):

.amnple.Custodian/Laboratory: ( ,f>(&'. cc'C. -

Telephoned to: On By Page 15 of 105

SAMLERECEIPT & REVIEW FORM NflAR0 Mn 8 Client: q '-fl 1516 SDG/ARCOC/Work Order:

Received By: T2737-r' Ca 4 _ _ _ __ _ _ _ __ _ _ _ _

Sample Receipt Criteria Comments/Qualiriers (Required for Non-Conforming Items) 1 Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) and sealed? _ _ _ _ _ __ _ _

Samples requiring cold Circle Coolant # ice bags blue ce dry ice oe P ru 2 preservation within (4 +/- 2 C)?

Record preservation method. - __ P _ n__

_ _

Chain of custody documents included with shipmi.ent?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking comainer odter (describe) sealed?

Samples requiring chemical Sample ID's, containers affected and observed pH:

reservation at proper pH?

VOA vials free of headspace Sample ID's and containersaffected:

(defined as < 6mm bubble)? _

Are Encore containers present?

7 (If yes, immediately deliver to VOA laborato!y)

Id's and ws af .

8 Samples received within holding time?

Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles?

Date & time on COC match date Sample D's affee:

& time on bottles?

Number of containers received Sample ID's affected:

match number indicated on COC?

COC form is properly signed in relinquished/received sections?

Air Bill ,Tracking #'s, & d -- q .

Additional Comments O OVA -- (

  • RSO RAD Receipt#

Suspected Hazard Information ""If > x2 area background is observed on samples identified as *non-Z 11 *regulated/non-radioactive", contact the Radiation Safety group for further C4 investigation.

A J adiological Classification? Maximum Counts Observed*:

B rPCB Reguat? Comments:

Shipped as )Uu rHazardous C IMaterial? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. 1

, PM (or PMA) review of Hazard classification: Initials & 1.- Date: *(, o 0 1 Page 16 of 105 1 1.

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY- 001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

,VontactName & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r,,

Priority: E 30 D. [] 14 D. []:7 D.

Samples Shipped Via:

0 Fed Ex El uPs C] Hand nl Other Bill of Lading #

  • Health Phys~s Pro~edure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major SCQnIul Yankee Atomic Power Company S".61hjun Hollow Road, East Hampton, CT 06424 860-267-2556 Contact Name & Phone:

Jack McCarthy -`860-267-2556 Ext. 3024 m E Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road.Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: M 30 D.[] 14 D. I 7 D.

Date Samples Shipped Via:

Z Fed Ex EuPS El Hand Ml Other Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List tj'~ 1 .20 Datc/Timric Receivcd: ,.)_ 12*. 0 G.

SDG#: AIc5R-O4- O&FF Work Order Number: /QV*32 /

Shipping Container ID: "*/iq-3 315- 8g Chain of Custody # Oo/, - 60T5o, 1

1. Custody Seals on shipping container intact? Yes No []
2. Custody Seals dated and signed? Yes No []
3. Chain-of-Custody record present? Yes No []
4. Cooler temperature ,'14

/

5. Vermiculite/packing materials is: Wet Y Dry [ )
6. Number of samples in shipping container: CI.
7. Sample holding times exceeded? Yes [] No V
8. Samples have:

k.tape hazard labels

_ custody seals appropriate.sample labels

9. Samples are:

_ in good condition __ 4 leaking broken have air bubbles

10. Were any anomalies identified in sample receipt? Yes No []

1I. Description of anomalies (include sample numbers):

Sample Custodian/Laboratorya r AI t._,. Date: J, 0 ~ d~

On Y.

Telephoned to: B Page 45 of 56 Page 19 of 105

Connecticut Yankee Statement of Work for Analytical Lab Services MCYISC-SOW-O01 Figure 1. Sample Check-in List.

Date/Time Received: a( AL*

SDG#:

Work Order Number: 3-7-.

ShippingCtaataiter IDe Chain of Custody#*k jOo,, - n0334 I. Custody Seals on shipping container intact?.. -Yes. ] No [e3)

2. Custody Seals dated and signed?

Yes'[ ].No f4 '

3. Chain-of-Custo.iy rocord present?

Yea N [No

4. Cooler emperature I ' .
5. Vermiculite/packing materials is: Wet [-?0Diry JVt 6: Number ofsamples in shipping container _ _"_J_ _,
7. Saaple hoding times.. xceeded?

.  : Ye s [ ] No ]

8.. Sampl have:-

- ".ta _..-hazard labels

-. o!..4Mu6dy seals -. appropriate sample labels

9. Samples amr:

.__.in good condti~on _*_.*L.ek ,.

r-"-broke " "." ihave air bubbles

10. Were any anomnalie identified in samýe receipt?.

Ye Desripi Ion ofYes W NNo J .. .D iption of aniomalies (lnclude sample numbers):

i 1>j h

.. .

. ."

S-amPleCustodian/Labor " . .

T elepho Teeboe to. ned tO,: _..Ry___..___,__Date.

  • -----__y_

' .

Page 20 of 105 ir

~-'

SAMPLE RECEIPT & REVIEW FORM 0

CONTINUATION FORM N'

_27,Cqq__O _ £, +/- 4C0("n'r, 1--- -- U21t Coto I 0o)-3i) S)V(

- loII5 ,9,pC*_ '-Oc "hS) ("(a ) _Swi i (I35 cag I a 1

- ~ 9ý3l-A~bn o31i 0017 s ccv-ri_.v h\cad 4" bLL5fec L1y o6 ue, l.r.v4i of ..

Page 21 of 105 I 1! 1

5 SAMPLE RECEIPT & REVIEW FORM a

PM me only Clint C4ý YLI SDG/ARCOCIWork Order: /4'?Y~3 Date Received: , (A) Review (ensure non-conforming items are resolved prior to signing):

[Seeved By: , A.,t'/h . _ _ ._ _ _ _ _ _ _ ...

__.

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items) leaking container other (describe) ircle Applicable: seals broken damaged container 1 Shipping containers received intact and sealed? r Samples requiring cold Cirle Coolant # ice bags blue ice dry ice none other describe) 2 preservation within (4 +/- 2 C)?

-Record preservation method.

Chain of custody documents 3included with shipment? a 4 Sample containers intact and Crle Applicable: seals broken damaged container I othr(describe) sealed? 910. 0I- ODDo .-- p 0 "

5 Samples requiring chemical Samnple Ms. containers affeeted and observed pH:

- preservation at proper pH?

VOA vials free of headspace Sample ID's and containers affected:

6 (defined as < 6rm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) _ _ _ _ .

_. . ..

8 Samples received within holding Id'S and tMtS aected:

time?

9 Sample ID's on COC match ID's Sp ID's and conins affected:

on bottles?

Date & time on COC match date Sm ID's affected:

& time on bottles? _

Number of containers received S amte D's affcted:

11 match number indicated on COC?

12 COC form is properly signed in relinfqushed/received sections? __ C-. A-*4 -" 6,#.,S 6&

14 Air Bill ,Tracking #'s, &

Additional Comments

. RADI Receipt- .

4 ; gj*If > x2.area background is obsered on samples identifiedason s ed r Inormation ulated/non-radioactive, contact the Radiation Safety group for'further A Radiological :Clamific~tion?

n IPCB Reglate-?: ________________Maximum - Counts Obseved*: < *, d

i. M;* as L"IrHa-aaous - , , , ,

C Material? If yes, contact Waste azardClam Shipped:

Manager or ESH Manager. y oN:

-P/AabP2!*qjw of Hazard classification: Initials Date: s--/7406;,

/

0 SAMPLE RECEIPT & REVIEW FORM

.0 PhM use only 14nnlClient. i 'SDGARCOC/Work Ordr: /6 Zr 2-,

IDate Received: c 1e PM(A) ( heawm resolved priw to signing):

Received By: (2 Qel ( i __+e,)_

Sample Receipt Criteria Comments/Qualrflers (Required rot Non.Conforinng Items) 1Shipping containers received intact cile Applicable: seals broken damaged co.t-iner leaking con-aiafr other (describe) and sealed? ... . ..... _ _ _ _ _ ,

Samples requiring cold Circk Coolmat I ice bags blue kce dry Ice ( other describe) 2 preservation within (4 +/- 2 C)? .

Record vreservation method.

110 C' Chain of custody documents -C0 CU,& Dx b \tj C+

included with shipmenI? /

T.t:PP, b

sa)$ i doena fC Cuflt Ickng com ter 4 Sample containers intact and sealed? Ctt Samples requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH? ... .........

(defined as free vials of headspace 6 VOA

- <6mm bubble)? ._._

Are Encore containers present? ,,

7 (If yes, immediately deliver to VOA laborato* r-)__ Id's and L-st

__ _ _

Samples received within holding ia:fcted time?

Sample ID's on COC match ID's Sample ID's amn etaamnes affected:

on bottles?

Date & time on COC match date Sample lD's affected:

&time on bottles?

Number of containers received Sample IDs affected:

match number indicated on COC?

COC form is properly signed in " c-"it '- vLu r31Ai,*-*

relinquished/received sections? . ...........

14 Air Bill ,Tracking 's, & cG0-H)')U.*cu4-C 0 Sh6e.+-

Additional Comments T [RSORADReccipt_#

Sq *If > x2 areabackground is observed on samples identified as "non-Sspected Hazard Information U 5 f regulated/non-radioactive". contact the Radiation Safety group for firtwer ad

  • investigation.

A Radiological Classification? - ]xium ..Counts Observed:t r PC gulatd?Comments:

Shipped as DOT Hazardous Material? If yes, contact Waste Hazard Class Shipped:

M Manager or 1 Manager.UNI:

PM (Owof 1C,-

Hazardclassication: Initials Date: .

ura -3 0I IUj Y4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-O0 ~ Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 1

Project Name: Haddam Neck Decommissic Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: 2 30 D.[] 14 D. E- 7 D.

Samples Shipped Via:

[ Fed Ex

[luPs C1 Hand n] Other Bill of Lading #

7'q&2 1,9.6"

Connecticut Yankee CY-lSC-SOW-01 Statement of Work for Analytical Lab Services .. , * ,jS..-O -

  • wL, Figure 1. Sample Check-in List Dateflime Received: 51'IIU SDG,*

Work Order Number:

LA Shipping Cof~tainer ID: ; " 57J - Chain of Custody # ",2,b 0O. l( / t Custody Seals owi shipping container intact? -Yes No["

  • 1.
2. Custody Seals dated and signed? Yes' jfNo [.

Chain-of-Custody record present?

Yes JP.4 No I ]

3.

Cooler temperature Igo(/

. - 9 -

4.

Vermiculite/packing materials is: 'Wet t.4Dry [,]

  • 5.
6. -Numberofsamples in shipping container: _
7. Sample holding times exceeded? Yes No NO
8. Samples have:'

L*Jtape . hazard labels

_.Zcustody seals -appropriate sample labels

9. Samples are:

in good condition -2*IeAkirg (Sill&e' 4~S broken -have air bubbles Yes 'I No [.,]

10. Were any anomalies identificd in sample receipt?
11. Description of anomalies (include sample numbers):

Telephoned to: On By Page 25 of 105*

SAMPLE RECEIPT & REVIEW FORM ff PM oe only g

Client: SDGIARCOCIWork Order: HIGZ-8*

Date Received: t PM(A) Review (ensure non-conro ug items are resolved prior to signing):

Received By:

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items) containers received intact Circle Applicable: seals broken damaged container leaking container ofter (describe)

',,Shipping Iabcsealed? ,

Circle Coolant # blue ice dry ice none oler describe)

Samp requiring cold ice bags 2 preservat within (4 +/- 2 C)?

Record 3reserv on method. .

3 Chain of custody d  ? s

'8

_included with shi ment?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking conmainer other (describe) sealed?

Samples requiring chemical Sample containets affected and observed pH:

'JIs.

- p r e s er v a tion a t pr o pe r pH ? S _ le D_I _sand_ ected :_ __ __ __ __ _ __aff 6 VOA vials free of headspace.Sample ID's and coainers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)"6Lt. ..

8. Samples received within holding id's aid te afected.

time?

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles?

Sample ID's affected:

10 Date & time on COC match date

& time on bottles?

Number of containers received Sample ID's affected:

match number indicated on COC?

12lCOC form is properly signed in 1relinquished/received sections?

14 Air Bill ,Tracking #'s, & F1 "5'.* ' - 4?5'2- -> /7 --

Additional Comments IRA #2499 -,->

V*"RSO RAD Receipt #

mat_1 c *If > x2 area background is observed on samples identified as *non-Suspected Hazard Information Z- p regulated/non-radioactive", contact the Radiation Safety group for fuirther

04. : l investigation.

kA Radiological Classification? - Maximum Counts Observed*:

B Full Regulated? Crucns fShipped as DXYI'Hazardous Material? If yes, contact Waste Hazard Class Shipped:

IManager or ESH Manager. UN#

PM (or PMA) review of Hazard.. classification:

,ragic 26 o f I6 * ... . Initials Date: 75 Y/

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company . . ,* . .

362 Injun Hollow Road, East Hampton, CT 06424 a .860-267-2556

ýfroject Name: Haddam Neck Decommissioning - Analyses Requested MI .

ýContact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 K, Analytical Lab (Name, City, State) .

General Engineering Laboratories .4 2040 Savage Road. Charleston SC. 29407 '

843 556 8171. Attn. Cheryl Jones cn Cn Priority: [ 30 D. [ 14 D. [ 7 D. Container -.. , ,

___________ ____Sample Size- 4 Media Type &Type W4 Sample Designation Date Time Code Code Code Comment, Preservation 9106-0006-004F 4/28/06 12:46 SE C BP X X Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP x x Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X X -Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP x x- Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP X X Transferred from COC 2006-00317 9106-0006-012F 45/21/06 13:40 SE C BP X X Transferred from COC 2006-00317 9106-0006-017F, 5/01/06 14:03 SE C BP X x Transferred from COC 2006-00317 NOTES: PO #: 002332 MSR #: 06- t4%1 SWP# NA M LTP n A r7 D*,dwast QA M Non f-,A Samples Shipped Via:

LI Fed Ex CHand

1) Relinquished By Date/Time 2) Received By ( "ate/Time 1
3) Relinquished By Date/Time 4) Received By late/Time Bill of Lading #

y

ýL wo- ?.ffo-4/

Connecticut Yankee CY-ISC-SOW-O01 Statement of Work for Analytical Lab Services

.. S -

Figure 1. Sample Check-in List Datfime Rccived:

" .

  • SDG#:

Work Order Number ShippingCdiltainer ID: Qt (C3f* -*,&ft Chain of CustodY# . &'

1. CustodySeals ozshipping container intact?.:

-Yss No(_kD

2. Custody Seals dated and signed? Yes No
3. Chain-of-Custody reord present?

Yesk).No [II

.. 4. Cooler temperature

. *5 ."r .1_

we

5. :Vermiculite/packing materials is:

Wet ) Dry [' ]

6.: -Number of samples in shipping containor

7. Sample holding imes exceeded?

Yes [ No t14

.8. Samples have-

_* __ape haz~ard labels

-J cstd se~ _approprateo sapllbels

9. ,Samples am' .

good condition leaking brokn .-. " have air bubbles

10. Were any anomalies identified in sample rCeipt?"

Yes [ No

11. .Description of anomalies (include sample numbers):

Sample Custodia./Laboratory: Of.* ,_ Date:/7 Telephoned to:0 .. "

Page 28ofl105

SRECEIPT & REVIEW FORM

-e4ORf iPM n only Chient: S.DG*ARCOCIWo rder: &Z r3"Z, Date Received: t:5-/ ýPM(A) Review (jue ncofalonn Ite1M uwereolved prior to signag):

eceived By: C .. .

Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)

Shipping containers received intact ircie Applicable: seals broken damaged conminer leaking container ofier (d*sibe) and sealed? ......

Samples requiring cold Circle Coolant # ice bags blue ice dry iCC c other descmr) 2 preservation within (4 +-A 2 C)?

Record preservation method. o0C.

Chain of custody documents COU S O-x 0 \tN L+

included with shipment?

Sample containers intact and damagedconuiner lakingcoaiwr ocscribc) sealed? ~ _0~.t~M.

qg'cŽIKQ~

Samples requiring chemical sa,,ic ID's. co,.aim affcccd and observed pH: 8q preservation at proper pH?

VOA vials free of headspace ISanle ID' and containers affected:

(defined as < 6mm bubble)? I Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) .....

Id's a t affece:

8 Samples received within holding time?

Sample ID's on COC match ID's le ID's wad conasmiers affectedt on bottles?

Date & time on COC match date Sanple ID's affected:

& time on bottles?

Number of containers received s,,,e W's affe*red:

match number indicated on COC?

COC form is properly signed in (CbeQs OL, Yuq-,

rVAj 3 .C1 relinquished/received sections? .I_

Air Bill ,Tracking #'s, & c. c '*+/- y )ULC,.-*

C. () I'JLL..

Additional Comments IV' RSO RAD ReciptI___________

Suspected Hazard Information *If > x2 area p R background is observed on samples identified as -non-Vd regulated/non-radioactive'. contact the Radiation Safety group for further Radiological Class/ficatiMn? aximum Counts Observed*:

PCU Regulated? Comments:

fShipped as D0 I Hazardous ClMaterial? If yes, contact Waste /Hazard Class Shipped:

Manager or ESH Manager. UN#:

I PM (or PMA) review of Hazard classification: Initials O-/ Date a .JLIL].U* V/

I SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM

-______________ ~ oo*OOe& U1-o S00u(

(91055 O53O6 09,0t~ (0~ y

-qqiq~00L( **:-t5*(q yl5*z nta, (h5.C je-3eJ haxcd m bt~sitd 5aM,_ __ __ __k_

c et ---- S-('_4_

bast _.d_ a~rnI Page 30 of 105

'1 T."

11

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00367 CD 362 Injun Hollow Road, East Hampton, CT 06424 /'/

Nae adanNc 860-267-2556 04 Project Name: Hddam Neck Decommissioning

-6 -- -

Lab Use Only Analyses Requested Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Aftt. Cheryl Jones C4 4 ,

Priority: Z 30 D. [ 14 D. [] 7 D. t z Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-001F 5/05/06 11:13 SE C BP X X X Transferred from COC #2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP X X x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X x x Transferred from COC 4 2006-00325 9106-0008-007F 5/5/06 15:03 SE C 13P X Transferred from COC # 2006-00325 9106-00 08-002F 5/5/06 13:10 SE C BP x x x Transferred from COC # 2006-00325 NOTES: PO 4: 002332 MSR#: 06- )7q3 SSWP#NA N LTP QA E3 Radwaste QA E] Non QA aamples Shipped Via: Internal Container

[5; Fed Ex Temp.: _ Deg. C

-uPs E-Hand Custody Sealed?

i I /

YO NO

1) elinqu sh
  • Date/Time 2) e ive Ya m *.*ime Custody Seal Intact?

] Other

3) inquished By Date/Time 4) Rdeeiveu Vy ate/Time YO NO 3ill of Lading #

I

Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major MConnecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00366 W362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 11o3-7 41 V.

Project Name: H{addam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 5.

843 556 8171. Attn. Cheryl Jones En Z Priority: N 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Comment, Preservation Lab Sample ID Sample Designation Date Time Code Code Code tJ) 9106-0008-008F 5/08/06 08:01 SE C BP X X - Transferred from COC # 2006-00327 9106-0008_-009F

_0 5/08/06 08:32 SE C BP x x x Transferred from COC # 2006-00327 oil 9106-0008-010F 5/08/06 09:09 SE C BP X X X Trans-fedfrom COC_#2006-00327-01I 91060008010F 5/08/06 09:09 SE C BP X X X Transferred from COC #2006-00327 OIL 9106-0008-01OFS 5/08/06 09:0 SE C BP x X X Transferred from COC # 2006-00327

)It 9106-0008-01 IF 5/08/06 09:30 SE C 13P x ___ x x Taserdfo C 20-02 I1 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC # 2006-00327 9106-0008-013F 5/08/06 10:16 SE C BP X x x Transferred from COC #2006-00327

ý5 9106-0008-014F 5/08/06 10:47 SE C BP x x x Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 67q3 SSWP# NA 0 LTP QA fl Radwaste QA [I Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: Z-I Deg. C F1 ups l Hand Custody Sealed?

YO N)!

1)Relinquished By Date/Time 2) Received By Date/Time Custody Seal Intact?

El Other

3) Relinquished By Date/Time 4) Received By Date/Time Y50 NO Bill of Lading#

Connecticut Yankee J1*3741 /

Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:- 6&iWb'Qo M 2\ )

SDG#:

Work Order Number:

Shipping Cotainer ID:.- - fr/, Chain of Custody # OOo - 00 3 ( Pq I. Custody Seals oan shipping container intact?. Yes [-,1'4o 1

2. Custody Seals dated and signed? Yesj[1 No q[-
3. Chain-of-Custody record present? Yes [-'o []

.4. Cooler temperature

5. Vermiculite/packing materials is: Wet ] Dry* I]/

6.' Number of samples in shipping container: 6

7. Sample holding times exceeded? Yes [ ] No

.8. Samples have:

-hazard labels

  • ~custody seals 7' appropriate sample labels
9. Samples arei

.in good condition leaking

  • broken -have air bubbles
10. Were any anomalies identified in sample receipt? Yes [ I No [,]"

11...Description of anomalies, (include sample numbers):

eampleoCustdiantLaboratry: - 5..w_________

  • Telephoned to.

Page 33 Of 105

9 SAMPLE RECEIPT & REVIEW FORM I'm we only IakeSDG/ARCOC/Wffk Order: lbV V,

[lent:

Date Received: '24AA PM(Al Revie (cmem RNn-~admuftitemun are remive prior to igalug):

Rec:ved By:

Sample Receipt Criteria CommnentQuaihiers (Required for Non.Conforming Items)

/Apllble: nab M*cn dnmaplcentimme lekhg c er e*dic (describe)

Shipping containers received intact Samples requiring cold bdC Caalm 0 ice bass blue ice dry ice %1 dmerdesaic 2preservation within (4 +/- 2CQ?/

Record preservation method.

Chain of custody documents

[ jmcchr~Sinhded with shipmentý? _______________

4Samplee containers intact and Cocke A~psicahl neab bteake darnsied conaliner leakftingceer ahi (describe) sealed?p~

Samples rd? uirin chemical / M'L coimeni aiffced and observed pH:

reservation at poer pH?

sf WSA'd comnainers aftlcled VOA vials free of beadspa (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes. Immediately deliver to VOA laboratory)

Samples received within holding 8 time? /n n 9 mle ID's on COC match ID's /ID'$ sow cinmers affecd*

on bottles?

ID's eafftco:

10 Date & time on COC match date

& time on bottles?

Numbcr of containers received match number indicated on COC?

/ID's aff'e:

COC form is properly signed in mreliquished/received sections?

Air Bill ,Tracking #-s, &

'""IditionalComens I

I I

I__________

A Suvsiptedi in .... . ...

ard Informaton 3naOiogkiai UlassitjCation-fP~4

.. . I . m it m I

. ul a II It5RAD Reccip f > ame relfX2 badkground is observed on sample idegiJ~d as nn t reguslated/nonradiatfmive", conwat the Padition Safety group hbr fiamhe

ýounft Observed*: Qa h,-1 ;Fý -p,., - k5o B

/

e a a regulated?

It A Class Shipped:

CCMatwerrial?,

MManager orif ESH Yes, contact Manager.

WasteIV __

I- nw ~or IMA) review of Hazard ciassiflaneinn*

............. i. L-*4LL6 4"- Date:

Page 34 of 105

SAMLERECEIPT & REVIEW FORM

'P4lrORItS' PM Useonly Ci.ent: ' & SDGIARCOC/Work Order: 37 /

Date Received: '57wI PM(A) Review (elisure non-confornling items ame resolve Prior to signing):

Received By: C 1A rfn h, ____________________

Sample Receipt Criteria ~CommentslQuallflers (Required for Non-Conforming Items)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe)

_and sealed? ,

Samples requiring cold Circle Coolant # ice bags blue ice dry ice otber describe) 2 preservation within (4 +/- 2 C)?

Record preservation method. f,1" Chain of custody documents

,includedwith shipment? Cirle _______sabbrke _d maed ___________cotane _ohe ______

Sample containers intact and Circle Applicable: seals broken damaged conainer leaking conainer othe (describe) sealed?

Samples requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH?

VOA vials free of headspace Sample ID's and contauiner affected:

(defined as < 6mm bubble)? ,_,_,

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Id's an tests affected:

8 Samples received within holding Vol, time?

9 Sample ID's on COC match ID's SanptID's and containers affected:

on bottles?

Date & time on COC match date Sample ID's affected:

& time on bottles?

Number of containers received a ID' affected:

match number indicated on COC?

COC form is properly signed in A04-"- 0,u...I'A*q ,4/, AW relinquished/reccived sections?

C--45r- 2~

-W C O - Late' 14 Air Bill Tracking #s, & 1 V,+ 4e 'j- 1- ,-5 Additional Comments "o' T RSO RAD Receipt #__H d .9 *if > x2 area background is observed on samples identified as "non-Suspected Hazard Information al regulated/non-radioactive*. contact the Radiation Safety group for further m investigation.

A Radiological Classification. -V Maximum Counts Observed*:'

B fPCB Regulated? Comments:

IShipped as DOT Hazardous .

C Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. U PM (or PMA) review of Hazard classiticauion: Initials Date:

I I Page 35 of 105

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received: _j(0ic to *3 SDG#:

Work Order Number:

Shipping Cdntainer ID: ' 1!56i1 I 73 Chain of Custody'# C"r-'*

1. Custody Seals. oii shipping container intact?... Yes j o
2. Custody Seals dated and signed? Yes f,,lo [ ]
3. Chaia-of-Custody record present? 'Yes LA41o [ ]
4. Cooler temperature
5. Vermiculite/packing materials is: Wet V*Dry [',]

6." Number of samples in shipping container: (* .a h A-

7. Sample holding times exceeded? Yes.[ NoD

.8. Samples have:

t .tape -hazard labels custody seals -appropriate sample labels

9. Samples are:
u"in good condition leaking

.broken -have air bubbles

10. Were any anomalies.identified in sample receipt? Yes [ ] No [.-<
11. Description of anomalies (include sample numbers): I P Sample Custodian/Laboratory: (c4 e" Date:___________________

Telephoned to: ^On By_

Page 36 of105 .

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major 164-4ol I Chain of Custody Form No. 2006-00380 CD Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 o 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested .Lab'.Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories <

2040 Savage Road. Charleston SC. 29407 C0 <

843 556 8171. Attn. Cheryl Jones V) Cn Priority: Z 30 D. El 14 D. El 7 D. Container Sample Size-Media Type &Type . "

Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID

  • 9106-0009-016F 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352

~9106-0009-01 6FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 SE C BP X Transferred from COC 2006-00351 9106-0009-017F 5/15/06 08:05 -

9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 0

m 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 OiV 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 9106-0009-014F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351

~~~

5/'50 9106-0009-015F ~

093IEC ~ B rnfre rmCC20-05 NOTES: PO #: 002332 MSR #: 06-O/g' SSWP# NA SLTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: ___ Deg. C El uis El Hand Custody Sealed?

YO NO

1) Relinquised By Date/Time 2) Rec v d y Date/Time Custody Seal Intact?

El Other

3) Relinquished By Date/Time 4) Re eive By Date/Time N !"

Y 17 Bill of Lading #

¢qz/.VS 2A-

Health Physics Procedure 1lI I

/1,4 gva -/. II GPP-GGGR-R5104-003 -Attachment B-CY-001 Major l

0( Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 CD 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only C

U Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C V Priority: E 30 D.[] 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-00IF 5/11/06 13:22 SE C BP X xX Transferred from COC 2006-00347 at* 9106-0009-002F 5/11/06 13:46 SE C BP x x Transferred from COC 2006-00347 A 9106-0009-003F 5/11/06 14:06 SE C BP x x Transferred from COC 2006-00347 b 9106-0009-004F 5/11/06 14:30 SE C BP X X - Transferred from COC 2006-00347 01$ 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347 0(:i/"9106-0009-007F 5/12/06 07:44 "SE C BP X X Transferred from COC 2006-00348 9106-0009-008F 5/12/06 08:16 SE C BP X X Transferrd from COC 2006-00348 (4.9106-0009-009F 5/12/06 08:35 SE C BP x X Transferred from COC 2006-00348 4 9106-0009-OIOF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA El Radwaste QA E] Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: _ Deg. C E] Hand Custody Sealed?

YO NO

1) Relinquished By Date/Time Date/Time Custody Seal Intact?

.Jf17k.1f 9...kr

-

1F 2 RZE&

-

c *

-- I e"/Al/0(. C?06 Ml Other

3) Relinquished By Date/Time t
4) Received By / bate/Time YO ND Bill of Lading #

fent! ly/y- z2yi-

7wq Connecticut Yankee Statement of Work for Analytical Lab Services CY-lSC-soW-o0 I Figure 1. Sample Check-in List

. G

.IV Date/Time Received- - B 0 (0 qt o%(5(

SDG#: ms C5"0 -0 e I Work Order Number: * - 2.91; MIS

',I Shipping Cdhtainer ID: "ti"- Chain of Custody # d.,_o6 2__ !8_ 1_

1. Custody Seals. oni shipping container intact? -Yes XJNo []
2. Custody Seals dated and signed? Yes [ No ,ND
3. Chain-of-Custody record pres ent? Yes 04 No LI
4. Cooler teemperature e0
5. Vermiculite/packing materials is: Wet H DryN [
6. Number of samples in shipping container:
7. Sample holding times exceeded? Yes D( No( I
8. Samples have:-

>..... * .__hazard labels

~ seals stody _appropriate sample labels

9. Samples are:
  • i good condition -leaking

-broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes[]No
11. * .Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:.. Date. 4 .. .

Telephoned to: On By, Page 39 of 105

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 cProject Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy .860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones X Priority: Z 30 D. [] 14 D. El 7 D. Container Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0010-001F 5/04/06 10:49 SE C BP X X Transferred from COC 2006-00321 010 9106-0010-002F 5/04/06 11:12 SE C BP X X Transferred from COC 2006-00321 0(1 9106-0010-004F 5/04/06 5/04/06 12:48 13:34 SE SE C C BP BP X X X Transferred from COC 2006-00321

___9106-0010-006F X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321

-9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 06 9106-0010-010F 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 o 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321

-0 9106-0010-013F 5/04/06 15:06 SE C BP X Transferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 07*07 SSWP#NA SLTP QA El Radwaste QA 0l Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: /7Deg. C EUPS ElHand CustodySealed?

Y9" NO

1) RelinquisheABy Date/Ti e 2) Received y Date/Time Custody Seal Intact?

El Other

3) Relinquished By DatefIime 4) Received By Date/Time Y9 ND Bill of LadingI#

~904- 3 ýf

Connecticut Yankee CY-ISC-SoW-O01 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List qMf / .06

/7 ,

  1. e Re ceiv ed :

D ate/ Tim SDG n U le . Q C# *

-7t9"70 Work Order Number:

Shipping Ccfitainer ID : rt5 850*'i Chain of Custody # - 396

1. Custody Seals ori shipping container intact? -Yes No[(][ J
2. Custody Seals dated and signed? Yes No[V[ I. -
3. Chain-of-Custody record present? Yes [D No [ ]
4. Cooler temperature (7 C
5. Vermiculite/packing materials is: Wet pq Dry J I' 6: of samples in shipping container:

! *Number _;

7. Sample holding times exceeded? Yes [ ] No Pq
8. Samples have:

-tape -h__hazard labels

.. s tody s e als u_-c pria te samp le labe ls

  • pm.ap 99in are:'good
9. Samples condition

-. jeaking

-broken -have air bubbles

10. W ere any anom alies identified in sample receipt? Yes [ No ] *KQ

~Description 1... of anomalies (include sample numbers):

Sarnple, Custodian/Lab~oratory: DaeG-~-O 4-0~d~

Telephoned to:. On By Page 41 of 105

ýt I'll Itt

A 'sSAMPLE

RECEIPT & REVIEW FORM 0
P1ro0R&" PM uise only Client
a , -X SDG/ARCOC/Work Order:

Date Received: S- I? -0,b PM(A) Review ( E 0 g item are resolved prior to signing):

Received By: 7-A4 Sample Receipt Criteria Z- -

Comments/Qualifiers (Required for Non-Conforming Items)

I Shipping containers received intact Circle Applicable: seals broken damaged conainer leaking container other (describe) and sealed? I Samples requiring cold Circlc Coolant # ice bags blue ice dry ice oiie) other describe) 2 preservation within (4 +/- 2 C)?

Record preservation method. ,_......

Chain of custody documents included with shipment?

4 Sample containers intact and ircle Applicabe seats broken damaged conainer Inking container other (describe) sealed?

Samples requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH? ,_

Sample ID's and containers affected:

6 VOA vials free of headspace (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding Id's and tests affected:

time?

Sample ID's on COC match ID's Sarmle tD's and containers affected:

on bottles?

Sample ID's affected:

10 Date & time on COC match date

& time on bottles? ......

Number of containers received Sampte ID's affected:

match number indicated on COC? V 12 COC form is properly signed in relinquished/received sections?

Air Bill ,Tracking #'s, & . .,,-

Additional Comments 31? 1 v -6 RSO RAD Receipt #

Suspected~ Infrnmio ~~*gaar *>-**x2 area background is observed on samples identified as "non-Suspected Haar Inomtinb regulated/non-radioactive". contact the Radiation Safety group for further A IRadiological Classification? Maximum Counts Observed*: 05^ 4 6 B PCB Regulat-e-d? " Conmmnts:

'Shipped as D0T Hazardous C Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. UN#:

PM (or PMA) review of Hazard classification: Initials 6 -Date: /_ ,-4 J-0 Z Page 42 of 105

List of current GEL Certifications as of 15 August 2006 State Certification Alaska UST-062 1 Arizona . AZ0668 Arkansas 88-0651 CLIA 42D0904046 -

California 01151ICA Colorado -GenEngLabs Conne-c*eticut -PH-0169.

Dept. of Navy NFESC413 EPA . . .WG-15J Florida/NELAP E8756 Georgia E87156 (FLJNELAP)

Idaho N/A Illinois 200029 Indiana . .. C-SC-0 .

Kansas E-10332 Kentucky 90129 Maryland 270 Massachusetts M-SCO 12 Michigan 9903 Nevada SCI-2 New Jersey SC002 New York 11501 North Carolina 233 North Carolina Drinking W 45709 NorthDakota R-158 Oklahoma 9904 Pennsylvania 68-485 ,

South Carolina 10120001/10585001/10120002 Tennessee _ 0293 4-Texas Tk-TX213-2006A U.S. Dept. of Agriculture S-52597-USArmy Corps of Engineer N/A -

Utah 8037697376 GEL Vermont N/A Virginia 00151 Washington C223 Page 43 of 105

RADIOLOGICAL ANALYSIS Page 44 of 105

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555696 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153129 Method Blank (MB) 1201153130 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153131 168340011(9304-01-005C) Matrix Spike (MS) 1201153132 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Page 45 of 105

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Page 46 of 105

Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 557837 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404009 9106-0006-005F 168404010 9106-0008-006F 1201158316 Method Blank (MB) 1201158317 168404009(9106-0006-005F) Sample Duplicate (DUP) 1201158318 168404009(9106-0006-005F) Matrix Spike (MS) 1201158319 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555697 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 48 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153133 Method Blank (MB) 1201153134 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153135 168340011(9304-01-005C) Matrix Spike (MS) 1201153136 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Page 49 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-i l-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555698 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 50 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-011F 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153137 Method Blank (MB) 1201153138 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153139 168340011(9304-01-005C) Matrix Spike (MS) 1201153140 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Page 51 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 556350 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 52 of 105

Sample ID Client ID 168404003 9106-0003-004F 168404004 9106-0003-015F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201154644 Method Blank (MB) 1201154645 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201154646 168404003(9106-0003-004F) Matrix Spike (MS) 1201154647 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F),

1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OOIF 168404015 9106-0010-012F 1201150561 Method Blank (MB) 1201150562 168340012(9304-02-003C) Sample Duplicate (DUP) 1201150563 168340012(9304-02-003C) Matrix Spike (MS) 1201150564 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

-Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Page 55 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555722 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 56 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153222 Method Blank (MB) 1201153223 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153224 168340012(9304-02-003C) Matrix Spike (MS) 1201153225 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Page 57 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Renanalysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555723 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 58 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 1201153226 Method Blank (MB) 1201153227 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153228 168340012(9304-02-003C) Matrix Spike (MS) 1201153229 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Page 59 of 105

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 554582 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150569 Method Blank (MB) 1201150570 168340011(9304-01-005C) Sample Duplicate (DUP) 1201150571 168340011(9304-01-005C) Matrix Spike (MS) 1201150572 Laboratory Control Sample (LCS)

Page 60 of 105

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Page 61 of 105

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 554583 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150573 Method Blank (MB) 1201150574 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201150575 168404003(9106-0003-004F) Matrix Spike (MS) 1201150576 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Page 62 of 105

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

Page 63 of 105

The following data validator verified the information presented in this case narrative:

Reviewer/Date: I*J S< z]46 Page 64 of 105

SAMPLE DATA

SUMMARY

Page 65 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 66 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANK01204 Sample ID: 168404001 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 20.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0762 +/-0.102 0.00 +/-0.102 0.0956 pCi/g BXLI 08/11/06 1336 555696 1 Curium-242 U 0.00 +/-0.0995 0.00 +/-0.0995 0.138 pCi/g Curium-243/244 U -0.00853 +/-0.0717 0.0405 +/-0.0717 0.177 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.199 +/-0.228 0.181 +/-0.229 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0341 +/-0.129 0.120 +/-0.129 0.323 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.0 +/-6.64 5.08 +/-6.72 10.7 pCi/g BXLI 08/16/06 1220 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.17 +/-6.67 5.28 +/-6.67 11.4 pCi/g DFA I 08/09/06 1128 554582 4 Liquid Scint C14, SolidAll,FSS Carbon- 14 U 0.0813 +/-0.0797 0.0634 +/-0.0797 0.132 pCi/g ATH2 08/09/06 0324 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 9.90 +/-48.1 32.0 +/-48.1 65.9 pCi/g MXPI 08/12/06 1633 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 +/-6.39 5.18 +/-6.40 10.6 pCi/g MXPI 08/11/06 0738 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.139 +/-0.213 0.173 +/-0.213 0.360 pCi/g EGD1 08/11/06 2027 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified Page 67 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANKO 1204 Sample ID: 168404001 Client ID: YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 80 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15%6-125%)

Carrier/Tracer Recovery Liquid Scint Pu24 1, Solid-ALL FS 98 (25%-I125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 68 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01 IF Project: YANKO 1204 Sample ID: 168404002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 17.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.120 +/-0.154 0.0683 +1-0.155 0.251 pCi/g BXL1 08/11/06 1336 555696 1 Curium-242 U -0.0146 +/-0.122 0.0692 +/-0.123 0.303 pCi/g Curium-243/244 U -0.0103 +/-0.0861 0.0487 +/-0.0862 0.213 pCi/g Alphaspec Pu, Solid-ALL FSS Plutoniurn-238 U 0.0121 +/-0.125 0.127 +/-0.125 0.344 pCi/g BXL1 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0254 +/-0.0675 0.0381 +/-0.0675 0.167 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 +/-7.02 5.56 +/-7.05 11.7 pCi/g BXLI 08/16/06 1237 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.521 +/-7.03 5.94 +/-7.03 12.8 pCi/g DFAI 08/09/06 1143 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.023 +/-0.0828 0.0685 +/-0.0828 0.143 pCi/g ATH2 08/09/06 0426 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 +/-47.7 31.9 +/-47.7 65.7 pCi/g MXP1 08/12/06 1649 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 +/-5.81 4.68 +/-5.81 9.60 pCi/g MXP I 08/11/06 0825 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 +/-0.203 0.164 +/-0.203 0.341 pCi/g EGDI 08/11/06 2043 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-1 I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 69 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-011F Project: YANK01204 Sample ID: 168404002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu24 1, Solid-ALL FS 88 (25°-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 70 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis o .. .... ..

C et.. if.. c .... t Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Proiect: YANK01204 Sample ID: 168404003 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 23.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 +/-0.117 0.153 +/-0.117 0.488 pCi/g BXLI 08/13/06 0819 555696 1 Curium-242 U 0.112 +/-0.315 0.245 +1-0.315 0.781 pCi/g Curium-243/244 U 0.0217 +/-0.206 0.205 +/-0.206 0.594 pCi/g Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.061 +/-0.189 0.176 +/-0.189 0.449 pCi/g BXL1 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0551 +/-0.103 0.0584 +/-0.103 0.215 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-5.73 4.40 +/-5.78 9.25 pCi/g BXLI 08/16/06 1253 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid ALL FSS Strontium-90 U -0.00343 +/-0.0203 0.0172 +/-0.0203 0.036 pCi/g BXFI 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 +/-8.25 6.87 +/-8.25 14.8 pCi/g DFAI 08/09/06 1159 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0937 +/-0.0813 0.0642 +/-0.0813 0.134 pCi/g ATH2 08/09/06 0529 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 7.68 +/-51.2 34.2 +/-51.2 70.4 pCi/g MXPI 08/12/06 1706 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 +/-7.12 6.58 +/-7.13 13.6 pCi/g MXP1 08/11/06 0912 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 +/-0.198 0.169 +/-0.198 0.351 pCi/g EGD1 08/11/06 2059 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified Page 71 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANKO 1204 Sample ID: 168404003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-11-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 42 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 92 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 113 (25%-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 59 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 71 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 83 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-1250/.)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANK01204 Sample ID: 168404003 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.

Page 73 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Proiect: YANK01204 Sample ID: 168404004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 22.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 +1-0.155 0.139 +/-0.155 0.387 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.113 +/-0.181 0.0733 +/-0.182 0.321 pCi/g Curium-243/244 U 0.180 +/-0.239 0.181 +/-0.240 0.472 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0196 +/-0.121 0.118 +/-0.121 0.324 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0326 +/-0.0639 0.00 +/-0.064 0.0884 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 +/-6.19 4.86 +/-6.22 10.2 pCi/g BXLI 08/16/06 1309 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00477 +/-0.0216 0.0179 +/-0.0216 0.0375 pCi/g BXF1 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 +/-7.06 5.85 +/-7.06 12.6 pCi/g DFAI 08/09/06 1215 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 +/-0.0912 0.0699 +/-0.0913 0.146 pCi/g ATH2 08/09/06 0632 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 +/-42.7 28.7 +/-42.7 59.2 pCi/g MXPI 08/12/06 1722 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 +/-10.1 10.3 +/-10.1 21.6 pCi/g MXPI 08/11/06 1001 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 +/-0.213 0.170 +/-0.213 0.353 pCi/g EGDI 08/11/06 2115 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified Page 74 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANK01204 Sample ID: 168404004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 78 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 101 (25%-I125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 58 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 62 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANKO 1204 Sample ID: 168404004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.

Page 76 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Project: YANK01204 Sample ID: 168404005 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: I C AO0 1 J.L' U0 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.036 +/-0.123 0.157 +/-0.123 0.437 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U -0.0169 +/-0.033 0.080 +/-0.0331 0.350 pCi/g Curium-243/244 U -0.0129 +/-0.227 0.247 +/-0.227 0.619 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0217 +/-0.163 0.181 +/-0.163 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.0708 +/-0.0791 0.128 +/-0.0795 0.337 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 9.52 +/-6.00 4.57 +/-6.07 9.61 pCi/g BXL1 08/16/06 1326 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.854 +/-5.88 4.87 +/-5.88 10.5 pCi/g DFAI 08/09/06 1231 554582 4 Liquid Scint C14, SolidAllFSS Carbon- 14 0.347 +/-0.097 0.0674 +/-0.0972 0.141 pCi/g ATH2 08/09/06 0734 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -1.57 +/-46.0 30.7 +/-46.0 63.2 pCi/g MXPI 08/12/06 1738 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 6.39 +/-7.62 7.40 +/-7.62 15.5 pCi/g MXPI 08/11/06 1017 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0198 +/-0.187 0.156 +/-0.187 0.324 pCi/g EGD1 08/11/062131 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-1 I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 77 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Project: YANKO 1204 Sample ID: 168404005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-1, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 95 (150/.-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 78 (15°/-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 ( 15°/o- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 78 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Project: YANK01204 Sample ID: 168404006 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 26.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0823 +/-0.203 0.178 +/-0.203 0.469 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U - 0.0154 +/-0.0301 0.0729 +/-0.0302 0.319 pCi/g Curium-243/244 U - 0.0994 +/-0.251 0.300 +/-0.251 0.713 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0466 +/-0.213 0.210 +/-0.213 0.521 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.142 +/-0.108 0.191 +/-0.109 0.483 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.64 +/-6.53 5.16 +/-6.57 10.8 pCi/g BXLI 08/16/06 1342 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -2.9 +/-7.59 6.60 +/-7.59 14.2 pCi/g DFAI 08/09/06 1247 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.(0352 +/-0.0868 0.0713 +/-0.0868 0.149 pCi/g ATH2 08/09/06 0837 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 1.88 +/-46.8 31.3 +/-46.8 64.4 pCi/g MXPI 08/12/06 1754 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 3.88 +/-7.46 7.40 +/-7.46 15.5 pCi/g MXPI 08/11/06 1033 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.(0894 +/-0.198 0.163 +/-0.198 0.338 pCi/g EGD1 08/11/06 2147 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 79 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Project: YANKO 1204 Sample ID: 168404006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 72 (15%o-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 72 (15°/-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 94 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-I125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 78 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 80 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-01 OF Project: YANK01204 Sample ID: 168404007 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 56.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -( 0.128 +/-0.0939 0.142 +/-0.0942 0.385 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. 0115 +/-0.128 0.147 +/-0.128 0.450 pCi/g Curium-243/244 U -0. 0333 +/-0.122 0.149 +/-0.122 0.401 pCi/g AIphaspec Pu, Solid-ALL FSS Plutonium-238 U 0. 0548 +/-0.169 0.158 +/-0.170 0.403 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0. 0195 +/-0.121 0.117 +/-0.121 0.322 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.4 +/-6.89 5.27 +/-6.97 11.1 pCi/g BXL1 08/16/06 1358 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.86 5.76 +/-6.86 12.4 pCi/g DFAI 08/09/06 1303 554582 4 Liquid Scint C14, SolidAll,FSS Carbon-14 U 0.0636 +/-0.0801 0.0644 +/-0.0801 0.135 pCi/g ATH2 08/09/06 1017 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 36.1 +/-44.1 28.7 +/-44.1 59.0 pCi/g MXPI 08/12/06 1811 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.26 +/-10.2 10.0 +/-10.2 20.9 pCi/g MXPI 08/11/06 1049 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.05 +/-0.199 0.169 +/-0.199 0.351 pCi/g EGDI 08/11/06 2203 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300. Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified 2

DOE EML HASL-300, Pu-1 I-RC Modified 3

4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 81 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010F Project: YANK01204 Sample ID: 168404007 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15%/o-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 92 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-1125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 82 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Proiect: YANKO 1204 Sample ID: 168404008 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 32.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00591 +/-0.219 0.231 +/-0.219 0.608 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.04 +/-0.0554 0.134 +/-0.0557 0.494 pCi/g Curium-243/244 U 0.0634 +/-0.261 0.249 +/-0.261 0.646 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0694 +/-0.106 0.160 +/-0.106 0.434 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.0287 +/-0.098 0.127 +/-0.0981 0.369 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 +/-8.01 6.48 +/-8.02 13.6 pCi/g BXLI 08/16/06 1415 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 +/-6.38 4.90 +/-6.38 10.6 pCi/g DFAI 08/09/06 1319 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0892 +/-0.0827 0.0655 +/-0.0827 0.137 pCi/g ATH2 08/09/06 1424 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 +/-46.3 30.6 +/-46.3 62.9 pCi/g MXPI 08/12/06 1827 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 +/-7.91 7.77 +/-7.91 16.2 pCi/g MXPI 08/11/06 1106 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.134 +/-0.192 0.167 +/-0.192 0.346 pCi/g EGDI 08/11/06 2218 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I -RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 83 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Proiect: YANKO 1204 Sample ID: 168404008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 61 (15o-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 74 (25°/-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a dilutedaliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 84 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Proiect: YANKO 1204 Sample ID: 168404009 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 16.5%

Parameter Qualifier R esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0. 0851 +/-0.136 0.106 +/-0.136 0.390 pCi/g BXLI 08/16/060949 557837 1 Curium-242 U -0. 0253 +/-0.0495 0.120 +/-0.0496 0.525 pCi/g Curium-243/244 U -0. 0479 +/-0.0542 0.131 +/-0.0545 0.443 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0. 0183 +/-0.113 0.110 +/-0.113 0.303 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.00122 +/-0.0662 0.0694 +/-0.0662 0.221 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.43 +/-5.83 4.67 +/-5.85 9.82 pCi/g BXLI 08/16/06 1431 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U - -2.02 +/-6.67 5.76 +/-6.67 12.4 pCi/g DFAI 08/09/06 1335 554582 5 Liquid Scint C14, SolidAll,FSS Carbon-14 (0.142 +/-0.0798 0.061 +/-0.0799 0.127 pCi/g ATH2 08/09/06 1719 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.6 +/-47.6 31.7 +/-47.6 65.3 pCi/g MXPI 08/12/06 1843 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.70 +/-9.56 9.31 +/-9.56 19.5 pCi/g MXPI 08/11/06 1122 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0 0659 +/-0.185 0.156 +/-0.185 0.323 pCi/g EGD1 08/11/06 2234 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-I I-RC Modified 5 EPA 906.0 Modified Page 85 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANK01204 Sample ID: 168404009 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 93 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 81 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 86 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Project: YANKO 1204 Sample ID: 168404010 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 05-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 34.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.129 +/-0.195 0.0758 +/-0.196 0.332 pCi/g BXLI 08/16/06 0949 557837 1 Curium-242 U 0.103 +/-0.202 0.00 +/-0.203 0.280 pCi/g Curium-243/244 U -0. 0161 +/-0.0316 0.0766 +/-0.0317 0.335 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.1 0276 +/-0.0711 0.0967 +/-0.0712 0.275 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.010359 +/-0.113 0.118 +/-0.113 0.317 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 14.9 +/-6.37 4.64 +/-6.51 9.75 pCi/g BXLI 08/16/06 1447 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.06 5.09 +/-6.06 10.7 pCi/g DFAI 08/10/062150 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0 .107 +/-0.0846 0.0664 +/-0.0846 0.139 pCi/g ATH2 08/09/06 1822 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 15.1 +/-41.4 27.5 +/-41.4 56.6 pCi/g MXPI 08/12/06 1900 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0'.258 +/-0.225 0.179 +/-0.225 0.373 pCi/g EGDI 08/11/06 2251 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-I I-RC Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified Page 87 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Project: YANKO 1204 Sample ID: 168404010 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 77 (15%- 125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%- 125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 103 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%/- 125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 71 (15%/- 125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H- Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 88 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO 1204 Sample ID: 168404011 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 35.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0. +/-0.192 0.152 +/-0.193 0.426 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. +/-0.142 0.132 +/-0.142 0.446 pCi/g Curium-243/244 U -0. +/-0.202 0.240 +/-0.203 0.603 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. +/-0.096 0.125 +/-0.096 0.328 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0. +/-0.114 0.137 +/-0.114 0.353 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 11.5 +/-6.72 5.08 +/-6.80 10.7 pCi/g BXLI 08/16/06 1504 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-5.92 4.97 +/-5.92 10.7 pCi/g DFAI 08/09/06 1407 554582 4 Liquid Scint C14, Solid A Il,FSS Carbon-14 U -0. 0238 +/-0.0745 0.0636 +/-0.0745 0.133 pCi/g ATH2 08/09/06 1924 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U - -10.7 +/-40.9 27.5 +/-40.9 56.8 pCi/g MXP1 08/12/06 1916 555722 6 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0. 0956 +/-0.211 0.174 +/-0.211 0.361 pCi/g EGDI 08/11/06 2307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified Page 89 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO 1204 Sample ID: 168404011 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%/o-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 96 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

  • QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 90 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANK01204 Sample ID: 168404012 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 11-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 33%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 +/-0.155 0.166 +1-0.155 0.458 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0192 +/-0.145 0.135 +/-0.145 0.455 pCi/g Curium-243/244 U 0.013 +/-0.268 0.281 +/-0.268 0.687 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 +/-0.0493 0.0279 +/-0.0494 0.122 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0186 +/-0.0492 0.0278 +/-0.0493 0.122 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 +/-6.90 5.13 +/-7.01 10.8 pCi/g BXLI 08/16/06 1520 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0151 +/-0.0146 0.0114 +/-0.0146 0.0242 pCi/g BXF1 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 +/-8.36 6.70 +/-8.36 14.5 pCi/g DFA1 08/09/06 1422 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.046 +/-0.0755 0.0613 +/-0.0755 0.128 pCi/g ATH2 08/09/06 2027 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 12.9 +/-40.6 26.8 +/-40.6 55.2 pCi/g MXPI 08/12/06 1932 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 +/-0.203 0.168 +/-0.203 0.348 pCi/g EGD1 08/11/06 2323 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- 11-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 91 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Project: YANK01204 Sample ID: 168404012 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Amr241, Cm, Solid ALL 61 (15/-,125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 94 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 92 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Proiect: YANKO 1204 Sample ID: 168404013 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 28.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 +/-0.242 0.230 +/-0.243 0.574 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0957 +/-0.220 0.171 +/-0.220 0.509 pCi/g Curium-243/244 U -0.073 +/-0.214 0.256 +/-0.214 0.627 pCi/g Alphaspec Pu, Solid ALL FSS Plutonium-238 U -0.00629 +/-0.0529 0.0299 +/-0.0529 0.131 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0262 +/-0.0513 0.00 +/-0.0514 0.0709 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 +/-6.66 4.95 +/-6.77 10.4 pCi/g BXLI 08/16/06 1536 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0205 +/-0.0151 0.0116 +/-0.0151 0.0246 pCi/g BXF1 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid HTD2,ALL FSS Tritium U 0.583 +/-7.98 6.65 +/-7.98 14.4 pCi/g DFA1 08/09/06 1438 554582 5 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.0271 +/-0.0759 0.0625 +/-0.0759 0.131 pCi/g ATH2 08/09/06 2129 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 +1-150 102 +1-150 210 pCi/g MXPI 08/12/06 1949 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628 +/-0.200 0.165 +/-0.200 0.343 pCi/g EGDI 08/11/06 2338 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 93 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21,,2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANK01204 Sample ID: 168404013 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-1125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 96 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 94 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-00IF Proiect: YANKO 1204 Sample ID: 168404014 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 27.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00677 +/-0.227 0.238 +/-0.227 0.628 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U 0.0854 +/-0.167 0.00 +/-0.168 0.231 pCi/g Curium-243/244 U 0.0361 +/-0.242 0.241 +/-0.242 0.634 pCi/g AIphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.173 +/-0.181 0.143 +/-0.182 0.331 pCi/g BXLI 08/11/06 2250 555697 2 Plutonium-239/240 U -0.0342 +/-0.0865 0.0951 +/-0.0866 0.235 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 +/-6.44 4.78 +/-6.54 10.0 pCi/g BXLI 08/16/06 1553 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0128 +/-0.0141 0.0125 +/-0.0141 0.0262 pCi/g BXFI 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.548 +/-7.50 6.25 +/-7.50 13.5 pCi/g DFA1 08/09/06 1454 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0555 +/-0.0809 0.0655 +/-0.0809 0.137 pCi/g ATH2 08/09/06 2232 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U -18.1 +/-47.6 32.3 +/-47.6 66.6 pCi/g MXPI 08/12/06 2005 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.134 +/-0.205 0.167 +/-0.205 0.347 pCi/g EGDI 08/11/06 2354 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300. Am-05-RC Modified 2 DOE EML HASL-300, Pu-1I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 95 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Project: YANK01204 Sample ID: 168404014 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-l, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25°-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25°%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 96 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANKO 1204 Sample ID: 168404015 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 28.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 +/-0.184 0.140 +/-0.184 0.386 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.0547 +/-0.141 0.192 +/-0.141 0.544 pCi/g Curium-243/244 U -0.126 +/-0.184 0.245 +/-0.185 0.597 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 +/-0.126 0.122 +/-0.126 0.291 pCi/g BXL1 08/11/06 2250 555697 2 Plutonium-239/240 U 0.0867 +/-0.0869 0.0406 +/-0.0872 0.128 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-6.16 4.77 +/-6.21 10.0 pCi/g BXLI 08/16/06 1609 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00771 +/-0.0144 0.0124 +/-0.0144 0.0263 pCi/g BXFI 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 +/-6.17 5.11 +/-6.17 11.0 pCi/g DFAI 08/09/06 1510 554582 5 Liquid Scint C14, Solid A /1,FSS Carbon-14 U 0.0162 +/-0.0763 0.0633 +/-0.0763 0.132 pCi/g ATH2 08/09/06 2334 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 23.3 +/-49.3 32.5 +/-49.3 67.0 pCi/g MXPI 08/12/06 2021 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 +/-0.206 0.171 +/-0.206 0.354 pCi/g EGD1 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 EPA 905.0 Modified Page 97 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 168404015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 81 (15%o-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (150/-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 99 (25%-I125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 74 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (I5%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 98 of 105

I QUALITY CONTROL DATA Page 99 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Renort Date: August 21, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 6 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 168404 Parmname NOM Samnle Oual OC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 555696 QCI201153130 168340011 DUP Americium-241 U -0.000522 U 0.0578 pCi/g 204 (0%- 100%) BXLI 08/11/06 14:34 Uncert: +/-0.0385 +/-0.278 TPU: +/-0.0385 +/-0.279 Curium-242 U 0.00 U -0.0405 pCi/g 200 (0%- 100%)

Uncert: +/-0.0756 +/-0.0562 TPU: +/-0:0756 +/-0.0565 Curium-243/244 U -0.0177 U -0.0517 pCi/g 98 (0%- 100%)

Uncert: +/-0.0764 +/-0.257 TPU: +/-0.0765 +/-0.257 QC1201153132 LCS Americium-241 12.8 12.8 pCi/g 100 (75%-125%)

Uncert: +/-1.84 TPU: +/-2.70 Curium-242 U -0.0328 pCi/g Uncert: +/-0.0454 TPU: +/-0.0457 Curium-243/244 15.5 14.3 pCi/g 92 (75%-125%)

Uncert: +/-1.94 TPU: +/-2.92 QC1201153129 MB Americium-241 U 0.0471 pCi/g Uncert: +/-0.157 TPU: +/-0.157 Curium-242 U -0.0469 pCi/g Uncert: +/-0.0459 TPU: +/-0.0464 Curium-243/244 U -0.00385 pCi/g Uncert: +/-0.210 TPU: +/-0.210 QCI201153131 168340011 MS Americium-241 13.3 U -0.000522 12.0 pCi/g 91 (75%-125%)

Uncert: +/-0.0385 +/-1.38 TPU: +/-0.0385 +/-2.08 Curium-242 U 0.00 U 0.0427 pCi/g Uncert: +/-0.0756 +/-0.0837 TPU: +/-0.0756 +/-0.0839 Curium-243/244 16.1 U -0.0177 15.9 pCi/g 99 (75%-125%)

Uncert: +/-0.0764 +/-1.58 TPU: +/-0.0765 +/-2.61 Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0%- 100%) BXLI 08/11/06 22:51 Page 100 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 2 of 6 Parmname NOM Sample Qual OC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 555697 Uncert: +/-0.0215 +/-0.0465 TPU: +/-0.0216 +/-0.0466 Plutonium-239/240 U 0.0414 U -0.0489 pCi/g 2410 (0%- 100%)

Uncert: +/-0.0934 +/-0.124 TPU: +/-0.0935 +/-0.124 QC1201153136 LCS Plutonium-238 U 0.155 pCi/g (75%-125%)

Uncert: +/-0.141 TPU: +/-0.142 Plutonium-239/2 4 0 11.8 11.5 pCi/g 98 (75%-125%)

Uncert: +/-0.856 TPU: +/-1.32 QC1201153133 MB Plutonium-238 U 0.0552 pCi/g 08/11/06 22:50 Uncert: +/-0.186 TPU: +/-0.186 Plutonium-239/2 4 0 U -0.0978 pCi/g Uncert: +/-0.0892 TPU: +/-0.0899 QC1201153135 168340011 MS Plutonium-238 u -0.0155 U 0.0539 pCi/g (75%-125%) 08/11/06 22:51 Uncert: +/-0.0215 +/-0.112 TPU: +/-0.0216 +/-0.112 Plutonium-239/240 12.3 U 0.0414 10.3 pCi/g 84 (75%-125%)

Uncert: +/-0.0934 +/-0.796 TPU: +/-0.0935 +/-1.19 Batch 555698 QC1201153138 168340011 DUP Plutonium-241 U 7.28 U 10.1 pCi/g (0% - 100%) BXLI 08/16/06 16:41 Uncert: +/-6.30 +/-6.39 TPU: +/-6.35 +/-6.46 QC1201153140 LCS Plutonium-241 137 145 pCi/g 106 (75%-125%) 08/16/06 17:14 Uncert: +/-12.5 TPU: +/-19.9 QC1201153137 MB Plutonium-241 U 8.57 pCi/g 08/16/06 16:25 Uncert: +/-6.93 TPU: +/-6.98 QC1201153139 168340011 MS Plutonium-241 138 U 7.28 142 pCi/g 103 (75%-125%) 08/16/06 16:58 Uncert: +/-6.30 +/-12.4 TPU: +/-6.35 +/-19.7 Batch 557837 QC1201158317 168404009 DUP Americium-241 U -0.0851 U 0.167 pCi/g 616 (0%- 100%) BXLI 08/16/06 09:49 Uncert: +/-0.136 +/-0.220 TPU: +/-0.136 +/-0.221 Curium-242 U -0.0253 U 0.241 pCi/g 247 (0%- 100%)

Page 101 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 3 of 6 Parmname NOM Sample_Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 557837 Uncert: +/-0.0495 +/-0.334 TPU: +/-0.0496 +/-0.335 Curium-243/244 U -0.0479 U 0.0761 pCi/g 879 (0% - 100%)

Uncert: +/-0.0542 +/-0.149 TPU: +/-0.0545 +/-0.149 QC1201158319 LCS Americium-241 24.5 25.4 pCi/g 104 (75%-125%)

Uncert: +/-2.47 TPU: +/-4.16 Curium-242 U 0.0477 pCi/g Uncert: +/-0.127 TPU: +/-0.127 Curium-243/244 29.7 27.0 pCi/g 91 (75%-125%)

Uncert: +/-2.54 TPU: +/-4.38 QCI201158316 MB Americium-241 U 0.234 pCi/g Uncert: +/-0.275 TPU: +/-0.277 Curium-242 U 0.00 pCi/g Uncert: +/-0.152 TPU: +/-0.152 Curium-243/244 U -0.0551 pCi/g Uncert: +/-0.0624 TPU: +/-0.0628 QC1201158318 168404009 MS Americium-241 26.4 U -0.0851 29.1 pCi/g 110 (75%-125%)

Uncert: +/-0.136 +/-2.97 TPU: +/-0.136 +/-5.01 Curium-242 U -0.0253 U 0.126 pCi/g Uncert: +/-0.0495 +/-0.247 TPU: +/-0.0496 +/-0.248 Curium-243/244 32.4 U -0.0479 31.7 pCi/g 98 (75%-125%)

Uncert: +/-0.0542 +/-3.12 TPU: +/-0.0545 +/-5.39 Rad Gas Flow Batch 556350 QC1201154645 168404003 DUP Strontium-90 U -0.00343 U -0.00637 pCi/g 0 (0% - 100%) BXFI 08/14/06 08:33 Uncert: +/-0.0203 +/-0.0152 TPU: +/-0.0203 +/-0.0152 QC1201154647 LCS Strontium-90 1.56 1.30 pCi/g 83 (75%-125%)

Uncert: +/-0.0563 TPU: +/-0.0881 QC1201154644 MB Strontium-90 U 0.0176 pCi/g Uncert: +/-0.018 TPU: +/-0.018 Page 102 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 4 of 6 Parmname NOM Sample Oual OC Units RPD% REC% Range Anist Date Time Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 1.58 U -0.00343 1.29 pCi/g 82 (75%-125%)

Uncert: +/-0.0203 +/-0.0535 TPU: +/-0.0203 +/-0.0813 Rad Liquid Scintillation Batch 554580 QC1201150562 168340012 DUP Technetium-99 U 0.0338 U 0.266 pCi/g 0 (0% - 100%) EGDI 08/12/06 00:42 Uncert: +/-0.192 +/-0.226 TPU: +/-0.192 +/-0.226 QC1201150564 LCS Technetium-99 13.1 13.6 pCi/g 103 (75%-125%) 08/12/06 01:14 Uncert: +/-0.496 TPU: +/-0.599 QC1201150561 MB Technetium-99 U 0.0311 pCi/g 08/12/06 00:26 Uncert: +/-0.177 TPU: +/-0.177 QCI201150563 168340012 MS Technetium-99 13.0 U 0.0338 12.0 pCi/g 92 (75%-125%) 08/12/06 00:58 Uncert: +/-0.192 +/-0.523 TPU: +/-0.192 +/-0.602 Batch 554582 QC1201150570 168340011 DUP Tritium U 1.77 U 1.62 pCi/g 0 (0% - 100%) DFA I 08/09/06 15:42 Uncert: +/-8.20 +/-7.47 TPU: +/-8.20 +/-7.47 QC1201150572 LCS Tritium 68.3 76.2 pCilg I11 (75%-125%) 08/09/06 16:14 Uncert: +/-14.0 TPU: +/-14.1 QC1201150569 MB Tritium U 0.586 pCi/g 08/09/06 15:26 Uncert: +/-8.01 TPU: +/-8.01 QC1201150571 168340011 MS Tritium 61.3 U 1.77 61.8 pCilg 101 (75%-125%) 08/09/06 15:58 Uncert: +/-8.20 +/-12.2 TPU: +/-8.20 +/-12.3 Batch 554583 QC1201150574 168404003 DUP Carbon- 14 U 0.0937 U 0.0422 pCi/g 0 (0% - 100%) ATH2 08/10/06 01:39 Uncert: +/-0.0813 +/-0.075 TPU: +/-0.0813 +/-0.0751 QC1201150576 LCS Carbon- 14 7.27 7.14 pCi/g 98 (75%-125%) 08/10/06 03:00 Uncert: +/-0.508 TPU: +/-0.520 QC1201150573 MB Page 103 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 5 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 554583 Carbon- 14 U -0.0315 pCi/g Uncert: +/-0.0776 TPU: +/-0.0776 QC1201150575 168404003 MS Carbon-14 15.1 U 0.0937 13.8 pCi/g 92 (75%-125%) 08/10/06 02:43 Uncert: +/-0.0813 +/-1.00 TPU: +/-0.0813 +/-1.03 Batch 555722 QC1201153223 168340012 DUP Iron-55 U -26.5 U 5.83 pCi/g 0 (0%- 100%) vIXPI 08/12/06 20:54 Uncert: +/-65.1 +/-36.9 TPU: +/-65.1 +/-36.9 QC1201153225 LCS Iron-55 641 660 pCi/g 103 (75%-125%) 08/12/06 21:27 Uncert: +/-56.2 TPU: +/-67.2 QC1201153222 MB Iron-55 U 18.2 pCi/g 08/12/06 20:38 Uncert: +/-39.6 TPU: +/-39.6 QC1201153224 168340012 MS Iron-55 717 U -26.5 688 pCi/g 96 (75%-125%) 08/12/06 21:11 Uncert: +/-65.1 +/-60.2 TPU: +/-65.1 +/-71.6 Batch 555723 QC1201153227 168340012 DUP Nickel-63 U 3.79 U 6.68 pCi/g 0 (0%- 100%) vIXPI 08/11/06 11:55 Uncert: +/-5.39 +/-7.43 TPU: +/-5.40 +/-7.43 QC1201153229 LCS Nickel-63 512 479 pCi/g 94 (75%-125%) 08/I 1/06 12:27 Uncert: +/-22.4 TPU: +/-27.1 QC1201153226 MB Nickel-63 U 15.7 pCi/g 08/11/06 11:38 Uncert: +/-9.92 TPU: +/-9.93 QC1201153228 168340012 MS Nickel-63 530 U 3.79 511 pCi/g 96 (75%-125%) 08/11/06 12:11 Uncert: +/-5.39 +/.23.5 TPU: +/-5.40 +/-28.7 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported Result is greater than value reported Page 104 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 6 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 105 of 105

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey Area Survey 0002 Survey Discharge Canal 90 Unit #: Unit Name:

Sample Plan or WPIR#: 2006-021 SML #: 9106-0002-014 Sample

Description:

Comparison of split samples collected from sample measurement location #014 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0002-014F the comparison sample was 9106-0002-014FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 0.OOE+00 2.22E-02 0 NONE - 1.13E-02 1.24E-02 N/A N/A Co-60 1.46E-03 1.07E-02 0 NONE- -8.41E-03 1.25E-02 -5.76 N/A Sr-90 -2.35E-03 8.OOE-03 0 NONE- -7.OOE-03 7.25E-03 2.98 N/A K-40 1.04E+01 5.15E-01 20 0.75 1.33 1.09E+01 5.40E-01 1.05 Y Comments/Corrective Actions: In consideration of Cs-137, Co- Table is provided to show acceptance criteria used 60 & Sr-90 results, guidance for agreement ranges, obtained to assess split samples.

from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of Resolution Agreement Range acceptability for such rations cannot be made. Since none of the 4 7 0.50 2.00 radionuclides of concern were in a comparable range, K-40 was 8 15 0.60 1.66 used to make the comparison and was found to be present at an 16 50 0.75 1.33 acceptable level of agreement, therefore, no further action is 51 200 0.80 1.25 warranted.

> 200 0.85 1.18 Performed By:

WPIR- Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey 9106 Survey 0002 Survey Unit Discharge Canal Area#: Unit #: Name:

Sample Plan or WPIR#: 2006-0021 SML #: 9106-0002-018 Sample

Description:

Comparison of split samples collected from sample measurement location #18 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0002-018F, the comparison sample was 9106-0002-018FS.

STANDARD COMPARI SON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 8.09E-02 1.54E-02 5 0.5 - 2 9.55E-02 2.89E-02 1.18 Y Co-60 1.45E-01 2.09E-02 7 0.5 - 2 3.25E-01 3.19E-02 2.24 N Sr-90 7.58E-03 5.60E-03 1 0.75 - 1.33 -2.42E-03 6.15E-03 -0.32 N/A K-40 1.04E+01 5.15E-01 20 0.75 1.33 1.09E+01 5.40E-01 1.05 Y i I I Comments/Corrective Actions: Since Co-60 has a likelyhood to Table is provided to show acceptance criteria used be present in the sample matrix in particulate form, one would to assess split samples.

not neccassarily expect it to be homogenuously mixed from processing of the sample-split aliqot. In consideration of Sr-90 Resolution Agreement Range results, guidance for agreement ranges, obtained from USNRC 4 7 0.50 2.00 Inspection Procedure 84750, does not address resolution ratios 8 15 0.60 1.66 less than 4, therefore, a determination of acceptability for such 16 50 0.75 1.33 rations cannot be made. Since both Cs-137 and K-40 were also 51 200 0.80 1.25 found to be present at an acceptable level of agreement, no further action is warranted. > 200 0.85 1.18 Performed By: Date 31 7~4~

WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2c Preliminary Data Forms (1 Page)

Health Physics Procedure GPP-GGGR-R512 1-001 Attachment B, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form - Samples for the Sign Test Survey Unit: 9106- 0002 Survey Unit Name: Discharge Canal Classification: 2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement: Radionuclide Specific Number of Measurements: 15 Operational DCGL: 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Sr-90 Minimum Value: 0.OOE+00 1.46E-03 -1.3 1E-02 Maximum Value: 3.81E-01 6.39E-01 2.14E-02 Mean: 1.36E-01 2.07E-01 4.24E-03 Median: 1.23E-01 1.45E-01 6.81 E-03 Standard Deviation: 9.83E-02 1.83E-01 9.52E-03 RADIONUCLIDE CONCENTRATION (pCi/g)

NUMBER Cs-137 Co-60 Sr-90 Identified? Identified? Identified?

9106-0002-002F 2.64E-02 2.13E-02 9.83E-03 Y Y N 9106-0002-004F 1.23E-01 1.19E-01 7.1 OE-03 Y Y N 9106-0002-005F 1.98E-01 2.88E-01 7.01 E-03 Y Y N 9106-0002-007F 3.81 E-01 6.39E-01 6.81 E-03 Y Y N 9106-0002-008F 1.63E-01 3.70E-01 7.85E-03 Y Y N 9106-0002-009F 1.84E-01 2.31E-01 2.94E-03 Y Y N 9106-0002-01 OF 6.61 E-02 2.38E-01 -1.06E-02 Y Y N 9106-0002-01 IF 2.47E-01 5.26E-01 1.95E-02 Y Y Y 9106-0002-012F 1.75E-01 1.18E-01 -4.47E-03 Y Y N 9106-0002-013F 2.43E-02 1.51E-01 -4.97E-04 N Y N 9106-0002-014F O.OOE+00 1.46E-03 -2.35E-03 N N N 9106-0002-015F 1.16E-01 5.07E-02 4.55E-03 Y Y N 9106-0002-017F 9.30E-02 8.07E-02 2.14E-02 Y Y Y 9106-0002-018F 8.09E-02 1.45E-01 7.58E-03 Y Y N 9106-0002-019F 1.69E-01 1.21 E-01 -1.31 E-02 Y Y N Performed By: Date:

Independent Review: Date:

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2d Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium - 137 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 1.36E-01 pCi/g Cs-i 37 Rank Percentage 0.OOE+00 1 3 %

2.43E-02 2 10 %

2.64E-02 3 17 %

6.61 E-02 4 23 %

8.09E-02 5 30 %

9.30E-02 6 37 %

1.16E-01 7 43 %

1.23E-01 8 50 %

1.63E-01 9 57 %

1.69E-01 10 63 %

1.75E-01 11 70 %

1.84E-01 12 77 %

1.98E-01 13 83 %

2.47E-01 14 90 %

3.81E-01 15 97 %

Prepared By: Date: /0 -2 ,- -0."

Reviewed By: Date: / ýr 1,g"

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cobalt - 60 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal 2.07E-01 pCi/g Mean:

7.00E-01

-, 6.00E-01 o.

0.

5.OOE-01 0o 4.00E-01 -

3.OOE-01 -

u 2.00E-01 o 1.OOE-01 __

0.00E+00 -

0 20 40 60 80 100 Percentage Co-60 Rank Percentage 1.46E-03 1 3 %

2.13E-02 2 10 %

5.07E-02 3 17 %

8.07E-02 4 23 %

1.18E-01 5 30 %

1.19E-01 6 37 %

1.21E-01 7 43%

1.45E-01 8 50 %

1.51E-01 9 57 %

2.31 E-01 10 63 %

2.38E-01 11 70%

2.88E-01 12 77 %

3.70E-01 13 83 %

5.26E-01 14 90 %

6.39E-01 15 97 %

Prepared By: 65Kf 2~Y Date: 10 04 Reviewed By: -- 4,. 47, Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Strontium - 90 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 4.24E-03 pCi/g 2.50E 2.OOE-02 1.50E-02 1.OOE-02 -

_ 5.00E-03 -

0.00E+00 -- l 4,0 60 80 1@0 o -5.OOE-03 ~ 0 ______ ___

-1.OOE-02 _

-1.50E-02 Percentage Sr-90 Rank Percentage

-1.31E-02 1 3 %

-1.06E-02 2 10 %

-4.47E-03 3 17 %

-2.35E-03 4 23 %

-4.97E-04 5 30 %

2.94E-03 6 37 %

4.55E-03 7 43 %

6.81 E-03 8 50 %

7.01 E-03 9 57 %

7.10E-03 10 63 %

7.58E-03 11 70%

7.85E-03 12 77 %

9.83E-03 13 83 %

1.95E-02 14 90 %

2.14E-02 15 97 %

Prepared By: Date:

Reviewed By: Date:  !

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 0.207 pCi/g 5 . .

T22 01....

0 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0.10 4 27%

0.20 5 33%

0.30 3 20%

0.40 1 7%

0.50 1 7%

0.60 1 7%

Total 15 87%

Prepared By: Date: / O -

5-c Reviewed By: Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs - 137 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 0.136 pCi/g 8

Cr *4-0*

2 --

0.10 0.20 0.30 0.40 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0.10 6 40%

0.20 7 47%

0.30 1 7%

0.40 1 7%

Total 15 100%

Prepared By: 6 t/- /41k4J2/ Date: 49 - ?.>>04C Reviewed By: Date: ,' 2 Tf 7

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Sr - 90 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 0.004 pCi/g Upper End Observation Observation %

Value Frequency Frequency 0.00 5 33%

0.02 9 60%

0.04 1 7%

Total 15 100%

Prepared By: Date: / 0 - Z -ý ... Z Reviewed By: Date: . e5-

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Phvsics Procedure GPP-GGGR-R512 1-000 Attachment A. Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes

urvey Unit Number
9106-0002 Survey Unit Name:

WP&IR#: Discharge Canal Classification : 2 TYPE I (cQerror):0.05 TYPE I (b error):0.05 Radionuclides: Cs-137 Co-60 Sr-90 Survey Design DCGL (pCi/g): 5.38 2.59 0.62 Results Cs-137 Results Co-60 Results Sr-90 Weighted Sum (Ws) DCGL-Result Sign 2.64E-02 2.13E-02 2.13E-02 2.251E-02 9.78E-01 I 1.23E-01 1.19E-01 1.19E-01 7.56E-02 9.24E-01 1 1.98E-01 2.88E-01 2.88E-01 1.55E-01 8.45E-01 1 3.81E-01 6.39E-01 6.39E-01 3.24E-01 6.76E-01I 1.63E-01 3.70E-01 3.70E-01 1.81E-01 8.19E-01 I 1.84E-01 2.31E-01 2.3 1E-01 1.26E-01 8.74E-01 1 6.61E-02 2.38E-01 2.38E-01 9.41 E-02 9.06E-01 I 2.47E-01 5.26E-01 5.26E-01 2.68E-01 7.32E-01 I 1.75E-01 1.1 8E-01 1.18E-01 7.38E-02 9.26E-01 I 2.431E-02 1.51E-01 1.51E-01 6.23E-02 9.38E-01 I 0.OOE+00 1.46E-03 1.46E-03 -1.67E-03 1.OOE+00 I 1.16E-01 5.07E-02 5.07E-02 4.55E-02 9.55E-01 I 9.30E-02 8.07E-02 8.07E-02 6.88E-02 9.31 E-0 I 8.09E-02 1.45E-01 1.45E-01 7.82E-02 9.22E-01 1.69E-01 1.21E-01 1.21E-01 6.57E-02 9.34E-01 Number of Positive Differences (S+): 15 Critical Value: II Survey Unit: Meets Acceptance Criterion Performed By: _ _ _

__Z ______ Date:_____________

ndependent Review: J .4K c". eo*- Date: /

Page 1 of 1

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (3 Pages)

DQA Surface Soil Report Assessment Summary Site: 9106-0002 Planner(s): Dale Randall Survey Unit Name: Discharge Canal Report Number: 1 Survey Unit Samples: 15 Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment

Conclusion:

Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve

--0

= 0.8 0.9 1.

-I zzz~z _

_

_

__

__

___

--

I-

  • 4-

, 0.7

2. 0.6 __ __ ~ i1
    • 0.5 FFFE___ __
  • 0.4

,* 0.3 r: 0.2 0.1 0.

0.0 0.2 0.4 0.6 0.8 1.0 1.2 Unity Rule Sum-of-Ratios, including baclground

- - Prospective Power 11-beta . Actual Power

.- LBGR I i Estimated Power DCGL ---- Retrospective Power COMPASS vI.0.0 1012312006 Page 1

DQA Surface Soil Report Survey Unit Data NOTE: Type = "S"indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number Type Co-60 (pCi/g) Cs-137 (pCi/g) SrY-90 (pCi/g) 9106-0002-002F S 0.03 0.02 0.01 9106-0002-004F S 0.12 0.12 0.01 9106-0002-005F S 0.2 0.29 0.01 9106-0002-007F S 0.38 0.64 0.07 9106-0002-008F S 0.16 0.37 0.01 9106-0002-009F S 0.18 0.23 0 9106-0002-01 OF S 0.07 0.24 -0.01 9106-0002-011 F S 0.25 0.53 0.02 9106-0002-012F S 0.18 0.12 0 9106-0002-013F S 0.02 0.15 0 9106-0002-014F S 0 0 0 9106-0002-015F S 0.12 0.05 0 9106-0002-017F S 0.09 0.08 0.02 9106-0002-018F S 0.08 0.14 0.01 9106-0002-019F S 0.17 0.12 -0.01 Modified Data (Unity Rule SOR)

NOTE: Type = "S"indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number Type Sum-of-Ratios (SOR) 9106-0002-002F S 0.04 9106-0002-004F S 0.13 9106-0002-005F S 0.23 9106-0002-007F S 0.56 9106-0002-008F S 0.24 9106-0002-009F S 0.2 9106-0002-OIOF S 0.1 9106-0002-011F S 0.36 9106-0002-012F S 0.15 9106-0002-013F S 0.06 9106-0002-014F S 0 9106-0002-015F S 0.1 9106-0002-017F S 0.12 9106-0002-018F S 0.11 9106-0002-019F S 0.13 10/2312006 Page 2 COMPASS vi COMPASS .0.0 v1.0.0 10/2312006 Page 2

W& DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=15 Mean (SOR) 0.17 N/A 0.14 Median (SOR) 0.13 N/A N/A Std Dev (SOR) 0.14 N/A 0.07 High Value (SOR) 0.56 N/A N/A Low Value (SOR) 0.00 N/A N/A 10/2312006 Page 3 COMPASS vl.0.0 vl.0.0 1012312006 Page 3