National Pollutant Discharge Elimination System Notification
ML070920323
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 03/19/2007
From: Jensen J
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:2401-16
Download: ML070920323 (6)


Text

Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place Bridgman, Ml 49106 AERcom A unit of American Electric Power March 19, 2007 AEP:NRC:2401-16 Docket Nos.: 50-315 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-PI-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NOTIFICATION Indiana Michigan Power Company is the holder of National Pollutant Discharge Elimination System (NPDES) permit M10005827 for Donald C. Cook Nuclear Plant. Section 3.2 to Part II of Appendix B (Environmental Technical Specifications) to Facility Operating Licenses DPR-58 and DPR-74 requires copies of reports of violations of the NPDES permit be submitted to the Nuclear Regulatory Commission (NRC).

In a letter dated March 16, 2007, the Michigan Department of Environmental Quality (MDEQ) was notified that a sample pump containing a small amount of oil was lost in the Unit 2 discharge piping.

Approximately 0.17 liters of seal oil is contained in the pump assembly. The pump could eventually be damaged by the high velocity flow and the tortuous path of the discharge to a point where the oil would be released to the environment. Due to the small volume of oil, this spill does not pose a threat to the environment, public health, or safety. The notification of this event was provided to MDEQ per Part II, Section C.7 of the NPDES permit. In accordance with the Environmental Technical Specifications, a copy of the report is hereby provided to the NRC.

Should you have any questions or concerns regarding this notification, please contact Mr. Jon H. Harner, Acting Environmental Manager, at (269) 465-5901, extension 2102.

Sincerely, o~seph N. Jensen Site Vice President JEN/rdw Attachment

U. S. Nuclear Regulatory Commission AEP:NRC:2401-16 Page 2 c: J. L. Caldwell - NRC Region III K. D. Curry - AEP Ft. Wayne, w/o attachment J. T. King - MPSC, w/o attachment MDEQ - WHMID/RPMWS, w/o attachment NRC Resident Inspector P. S. Tam - NRC Washington DC

ATTACHMENT TO AEP:NRC:2401-16 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NOTIFICATION TO MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY

Indiana Michigan IIMDYANA Power Company INDIANACook Nuclear Plant MICHIGAN One Cook Place PO*EI R Bridgman, MI 49106 Mr. Greg Danneffel, District Supervisor Surface Water Quality Division Michigan Department of Environmental Quality 7953 Adobe Road Kalamazoo, MI 49009 March 16, 2007

Dear Mr. Danneffel:

Subject:

Donald C. Cook Nuclear Plant NPDES Permit No. M1 0005827 This notification is made pursuant to Donald C. Cook Nuclear Plant's (CNP) NPDES Permit MI 0005827, Part II, Section C.7, Spill Notification.

On March 8, 2007, at 1618 hours0.0187 days <br />0.449 hours <br />0.00268 weeks <br />6.15649e-4 months <br />, CNP Environmental department was notified that a sample pump containing a small amount of oil was lost in the Unit 2 discharge piping. Approximately 0.17 liters of seal oil is contained in the pump assembly. The pump could eventually be damaged by the high velocity flow and the tortuous path of the discharge to a point where the oil would be released to the environment. Due to the small volume of oil, this spill does not pose a threat to the environment, public health, or safety.

The pump had been out of service for repairs, and apparently vibrated loose after re-installation.

CNP personnel performed a visual inspection of the plant's discharges and the beach in the vicinity of the Unit 2 discharge. No sheen or oil was observed during the inspection on the afternoon of March 8, 2007.

Your office was notified of the spill at 1654 hours0.0191 days <br />0.459 hours <br />0.00273 weeks <br />6.29347e-4 months <br /> on March 8, 2007. Due to safety issues, a recovery of the pump from the 1200 foot long discharge pipe is not possible. Visual inspections of the discharge area are planned for this spring and summer when CNP personnel will also look for and recover the lost pump, if possible.

2007-252

Mr. Greg Danneffel Page 2 March 16, 2007 Should you have any questions, please contact me at (269) 465-5901, extension 2102.

Sincerely, Jon H. Harner Acting Environmental Manager BKZ/jen c: Sgt. Michael Bradley - LEPC Ms. Noreen Hughes - HSEES Lake Township Fire Chief Ms. Susan Parker - SERC Ms. Lorraine Thomas, MDEQ - Kalamazoo Mr. John Vollmer, MDEQ - Kalamazoo 2007-252

Mr. Greg Danneffel Page 3 March 16, 2007 Re: Cook Nuclear Plant NPDES Permit No. MI 0005827 I certify under penalty of law that I have personally examined and am familiar with the information submitted on this and all attached documents; and based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment.

Jon H. Hamer Acting Environmental Manager 2007-252