Revision F to Emergency Plan Procedure EP-AA- 112-100-F-07, Mid-Atlantic ERO Notification or Augmentation
ML103260140
Person / Time
Site: Peach Bottom, Oyster Creek, Three Mile Island, Limerick
Issue date: 11/11/2010
From: David Helker
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA-10-087, TMI-10-114 EP-AA- 112-100-F-07, Rev F
Download: ML103260140 (33)


Text

Exekrin.Exelon Nuclear 200 Exelon Way Kennett Square, PA 19348 www.exeloncorp.com Nuclear 10CFR50, Appendix E TMI-10-114 RA- 10-087 November 11,2010 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353 Oyster Creek Nuclear Generating Station Renewed Facility Operating License No. DPR-1 6 NRC Docket Nos. 50-219 and 72-15 Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. 50-277 and 50-278 Three Mile Island Nuclear Station, Unit 1 Renewed Facility Operating License No. DPR-50 NRC Docket No. 50-289 Three Mile Island Nuclear Station, Unit 2 Possession-Only License No. DPR-73 NRC Docket No. 50-320

Subject:

Emergency Plan Procedure EP-AA- 112-100-F-07, Revision F, "Mid-Atlantic ERO Notification or Augmentation" Enclosed is the subject Emergency Plan Procedure revision for the following facilities:

  • Limerick Generating Station, Units 1 and 2* Oyster Creek Nuclear Generating Station* Peach Bottom Atomic Power Station, Units 2 and 3* Three Mile Island, Units 1 and 2)Jq ~(D A4_14-U.S. Nuclear Regulatory Commission November 11, 2010 Page 2 This procedure is required to be submitted within thirty (30) days of its implementation in accordance with 1 OCFR50, Appendix E, and 1 OCFR50.4.There are no commitments in this letter. If you have any questions or require additional information, please contact Richard Gropp at (610) 765-5557.Respectfully, David P. Helker Manager -Licensing Exelon Generation Company, LLC Enclosure cc: Regional Administrator

-NRC Region I NRC Project Manager, NRR -Limerick Generating Station NRC Project Manager, NRR -Oyster Creek Nuclear Generating Station NRC Project Manager, NRR -Peach Bottom Atomic Power Station NRC Project Manager, NRR -Three Mile Island NRC Senior Resident Inspector

-Limerick Generating Station NRC Senior Resident Inspector

-Oyster Creek Nuclear Generating Station NRC Senior Resident Inspector

-Peach Bottom Atomic Power Station NRC Senior Resident Inspector

-Three Mile Island PSEG -Financial Controls and Co-Owners Affairs (w/o Enclosure)

R. R. Janati, Commonwealth of Pennsylvania (w/o Enclosure)

S. T. Gray, State of Maryland (w/o Enclosure)

ENCLOSURE EP-AA-112-100-F-07, Revision F"Mid-Atlantic ERO Notification or Augmentation" Exe nEP-AA-1 12-1 00-F-07_ Revision F Nuclear Page 1 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION This revision is a major rewrite; no revision bars are shown The automated system will initiate the call out of management and bargaining unit personnel required to meet the ERO staffing requirements.

Additional staffing of personnel shall be the responsibility of the individual Managers and Directors in the TSC / OSC / EOF / ENC /JIC following initial activation of those facilities.

Automated Activation of the Primary Call Out System REFER to Section 1 Manual Activation of the Primary Call Out System REFER to Section 2 Manual Activation of the Backup Call Out System REFER to Section 3 Call Out System Scenario Cancellation REFER to Section 4 Alternate Pager Notification Method REFER to Section 5 NOTE: If cancellation of the call out scenario is required once activated, proceed to Section 4, Call Out System Scenario Cancellation.

1. AUTOMATED ACTIVATION OF THE PRIMARY CALL OUT SYSTEM NOTE: The automated call out system provides the following options: 1.1 ERO Response To Site Facilities For Alert, Site Area Emergency, General Emergency, or Security Events with ERO reporting to site facilities.

Optional for all other Unusual Events.1.2 Security Event ERO Response To Alternate Reporting Location For Security Events or other events as determined by the Shift Emergency Director with ERO reporting to off-site facilities.

1.3 Management Notification Only For Unusual Events excluding Security Events Attachments 1 through 4 present Section 1, Automated Activation of the Primary Callout System, in a site-specific flowchart format and may be used to implement Section 1 of this procedure.

Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 2 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 1.1. If ERO Response To Site Facilities is required, then PERFORM the following steps: NOTE: Multiple automated voice prompts will be heard throughout the call sequence.

The EP Pre-Programmed Phone is programmed to automatically input the required key strokes to complete the activation sequence EXCEPT for the actions directed in bold. The Communicator must take action ONLY for the voice prompts described in bold.1.1.1. If the EP Pre-Programmed Phone does not operate, then L[i PROCEED to SECTION 2, Manual Activation of the Primary Automated Call Out system.1.1.2. LIFT phone receiver or select Speaker phone option and VERIFY LJ the EP Pre-Programmed phone has dial tone.1.1.3. PRESS the "Part 1 ERO Response Required" Button. I-I 1.1.4. When voice prompt states, "...You entered (LGS -801, OC -901, LI PB -1001, TMI- 1101). Is that correct? Press 9 for Yes or 6 for No," then PRESS 9 for Yes and Continue.

Otherwise, HANG UP and RETURN to step 1.1.2.1. If the number is busy or does not answer with the appropriate

[I voice prompt after a 2nd attempt, then PROCEED to SECTION 3, Manual Activation of the Backup Call Out System.1.1.5. PRESS the "Part 2 ERO Response Required" button. LI 1.1.6. When the voice prompt says "Good-bye", then HANG UP the 0I phone.1.1.7. RECORD the time of the Call Out System Initiation L 1.1.8. If the "Good-bye" prompt is not received and the voice prompts have ended, then: 1. HANG UP phone. L1 2. WAIT five (5) seconds. L[3. REPEAT Steps 1.1.2 through 1.1.6. 17 Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 3 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 1.1.9. If the "Good-bye" prompt is not received after 2nd attempt, then Li PROCEED to Section 2, Manual Activation of the Primary Automated Call Out System, to manually initiate the Call Out system using any available phone. (e.g., 4-digit, cell phone, satellite phone.)1.1.10. If confirmation of the scenario activation is not verified via confirmation return phone call within approximately 10 minutes, then Li PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.1.1.11. INFORM Shift Emergency Director of the status of the Call Out L3 System initiation.

1.1.12. VERIFY that a call to the Control Room from the call Out System is Li received approximately 10 minutes after the system was initiated.

1.1.13. RECORD the time of the scenario confirmation call to the Control LI Room.1.1.14. If an "Initial Qualifiers" Report is not faxed to the Control Room Li approximately 20 minutes after the system was initiated, then PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.1.1.15. INFORM the Shift Emergency Director of the status of the Call Out L'System Initiation and EXIT this procedure.

Document Retention SRRS ID -5B. 100 EP-AA-1 12-1 00-F-07 Revision F Page 4 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 1.2. If ERO Response To Alternate Reporting Location Is Required for a Security Event, then perform the following steps: NOTE: Multiple automated voice prompts will be heard throughout the call sequence.

The EP Pre-Programmed Phone is programmed to automatically input the required key strokes to complete the activation sequence EXCEPT for the actions directed in bold. The Communicator must take action ONLY for the voice prompts described in bold.1.2.1. If the EP Pre-Programmed Phone does not operate, then go to L[SECTION 2, Manual Activation of the Primary Automated Call Out System.1.2.2. LIFT phone receiver or select Speaker phone option and VERIFY El the EP Pre-Programmed phone has dial tone.1.2.3. PRESS the "Part 1 ERO Response to Off-site Reporting Location" L3 Button.1.2.4. When voice prompt states "...You entered (LGS -820, OC -920, PB -1020, TMI -1120). Is that correct? Press 9 for Yes or 6 for LI No," then PRESS 9 for Yes and CONTINUE.

Otherwise, HANG UP and RETURN to step 1.2.2.1. If the number is busy or does not answer with the appropriate LI voice prompt after a 2nd attempt, then PROCEED to SECTION 3, Manual Activation of the Backup Call Out System.1.2.5. PRESS the "Part 2 ERO Response to Offsite Reporting Location" LI button.1.2.6. WHEN the voice prompt says "Good-bye", then HANG UP. EL 1.2.7. RECORD the time of the Call Out System Initiation LI 1.2.8. If the "Good-bye" prompt is not received and the voice prompts have ended, then: 1. HANG UP phone. LI 2. WAIT five (5) seconds. LI 3. REPEAT Steps 1.2.2 through 1.2.6. LI Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 5 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 1.2.9. If the "Good-bye" prompt is not received after 2nd attempt, then ii PROCEED to Section 2, Manual Activation of the Primary Automated Call Out System, to manually initiate the Call Out system using any available phone. (e.g., 4-digit, cell phone, satellite phone.)1.2.10. If confirmation of the scenario activation is not verified via U confirmation return phone call within approximately 10 minutes, then PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.1.2.11. INFORM Shift Emergency Director of the status of the Call Out UI-System initiation.

1.2.12. VERIFY that a call to the Control Room from the call Out System is U received approximately 10 minutes after the system was initiated.

1.2.13. RECORD the time of the scenario confirmation call to the Control UII Room.1.2.14. If an "Initial Qualifiers" Report is not faxed to the Control Room --approximately 20 minutes after the system was initiated, then PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.1.2.15. INFORM the Shift Emergency Director of the status of the Call Out --System Initiation and EXIT this procedure.

Document Retention SRRS ID- 5B.100 EP-AA-1 12-1 00-F-07 Revision F Page 6 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 1.3. If Management Notification Only is required, then PERFORM the following steps: NOTE: Multiple automated voice prompts will be heard throughout the call sequence.

The EP Pre-Programmed Phone is programmed to automatically input the required key strokes to complete the activation sequence EXCEPT for the actions directed in bold. The Communicator must take action ONLY for the voice prompts described in bold.1.3.1. If the EP Pre-Programmed Phone does not operate, then I-i PROCEED to SECTION 2, Manual Activation of the Primary Automated Call Out system.1.3.2. LIFT phone receiver or select.Speaker phone option and VERIFY 1i the EP Pre-Programmed phone has dial tone.1.3.3. PRESS the "Part 1 Management Notification Only" Button. Ll 1.3.4. When voice prompt states "...You entered (LGS -811, OC -911, [7 PB-1011, TMI- 1111). Is that correct? Press 9forYes or6 for No," then PRESS 9 for Yes and CONTINUE.

Otherwise, HANG UP and RETURN to step 1.3.2.1. If the number is busy or does not answer with the appropriate voice prompt after a 2nd attempt, then PROCEED to SECTION Li 3, Manual Activation of the Backup Call Out System.1.3.5. PRESS the "Part 2 Management Notification Only" button. 0i 1.3.6. When the voice prompt says "Good-bye", then HANG UP. L[1.3.7. RECORD the time of the Call Out System Initiation LI 1.3.8. If the "Good-bye" prompt is not received and the voice prompts have ended, then: 1. HANG UP phone. Li 2. WAIT five (5) seconds. [0 3. REPEAT Steps 1.3.2 through 1.3.6. Li Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 7 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 1.3.9. If the "Good-bye" prompt is not received after 2nd attempt, then PROCEED to Section 2, Manual Activation of the Primary Automated Call Out System, to manually initiate the Call Out system using any available phone. (e.g., 4-digit, cell phone, satellite phone.)1.3.10. If confirmation of the scenario activation is not verified via 0 confirmation return phone call within approximately 10 minutes, then PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.1.3.11. INFORM Shift Emergency Director of the status of the Call Out L]System initiation.

1.3.12. VERIFY that a call to the Control Room from the call Out System is received approximately 10 minutes after the system was initiated.

1.3.13. RECORD the time of the scenario confirmation call to the Control [7 Room.1.3.14. If an "Initial Qualifiers" Report is not faxed to the Control Room [U approximately 20 minutes after the system was initiated, then PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.1.3.15. INFORM the Shift Emergency Director of the status of the Call Out rl System Initiation and EXIT this procedure Document Retention SRRS ID -5B.100 EP-AA-1 12-1 00-F-07 Revision F Page 8 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 2.2.1.2.2.2.3.2.4.2.5.MANUAL ACTIVATION OF THE PRIMARY CALL OUT SYSTEM If an unexpected response is obtained during the activation attempt, then HANG UP the phone and PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.CIRCLE the station specific scenario number in step 2.5 below.DIAL the Automated Call Out system Activation phone number: 1-877-486-6612 If the number is busy or does not answer after a 2 nd attempt, then PROCEED to Section 3, Manual Activation of the Backup Automated Call Out System.When the System prompts, "This is the remote activation module.Please enter your scenario activation password followed by the# sign," then ENTER the scenario activation password from the table below for the scenario, followed by the "#" button.r-i Li Li Li Li On Site ERO Response ERO Response Required Required to Alternate Management Reporting Location for For Alert, Site Area, or Notification Only Security Events Station General Emergency, or Security Events with On Unusual Events excluding For Security Events with Site ERO reporting Security Events Off Site ERO reporting or (HU1) other events as*Optional for all other determined by the Unusual Events Emergency Director Limerick Station 801 811 820 Oyster Creek 901 911 920 Peach Bottom 1001 1011 1020 TMI 1101 1111 1120 Document Retention SRRS I D -5B.100 EP-AA-1 12-1 00-F-07 Revision F Page 9 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 2.6. When the system repeats the number just entered, then VERIFY the [U number is correct and PRESS the "9" button for Yes.2.6.1. If the number is not correct, then PRESS "6" and RE-ENTER the correct number. rl 2.7. When the system states, "To start a scenario, enter the scenario L-i ID followed by the # sign or press # alone for more options," then ENTER the number previously entered in Step 2.4, followed by the "#" button.2.8. When the System repeats the number just entered, then VERIFY L[that number is correct and PRESS the "9" button for Yes.2.8.1. If the number is not correct, then PRESS "6" and RE-ENTER the correct number. [J 2.9. When the System states, "To Start the Scenario Press 3. To L-i Return to the Main Menu press #," then PRESS the "3" button to start the scenario.NOTE: The System will state, "The scenario is building." 2.10. When prompted, then PRESS the "#" button to exit. 0i 2.11. If the "Good-bye" prompt is not heard after the 2 nd attempt (the Lri system was not successfully activated), then PROCEED to Section 3, Manual Activation of the Backup Call Out System, to attempt to manually initiate the callout system via any available touchtone telephone (e.g. 4-digit station telephone, satellite telephone, or cellular/mobile telephone).

2.12. IF the system provides a voice prompt other than "Good-bye," then: L3 2.12.1. HANG UP the receiver.

0 2.12.2. WAIT five (5) seconds L[2.12.3. REPEAT Steps 2.1 through 2.10 [-2.13. When the system provides the prompt, "Good-bye," then HANG UP [the receiver.Record the time of the call out system initiation:

Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 10 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 2.14. If confirmation of the scenario activation is not verified via L[confirmation return phone call within approximately 10 minutes, then PROCEED to Section 3, Manual Activation of the Backup Call Out System.2.15. VERIFY that a call to the Control Room from the call out system is [1]received within 10 minutes of system initiation.

RECORD time of telephone call to the Control Room: 2.16. INFORM the Shift Emergency Director of the status of the call out L[system initiation 2.17. If an "Initial Qualifiers" report is not faxed to the Control Room within 1 20 minutes of activation, then PROCEED to Section 3, Manual Activation of the Backup Call Out System.2.18. INFORM the Shift Emergency Director of the status of the Call Out [)System Initiation and EXIT this procedure Document Retention SRRS ID -5B.100 EP-AA-1 12-1 00-F-07 Revision F Page 11 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 3.MANUAL ACTIVATION OF THE BACKUP CALL OUT SYSTEM 3.1. If an unexpected response is obtained during the activation attempt, then HANG UP the phone and PROCEED to Section 5, Alternate Pager Notification Method.3.2. CIRCLE the station specific scenario number in step 3.6 below.3.3. DIAL the Backup Call Out System activation number: 1-800-308-8836.

3.4. When the system will states "This is the remote activation module.Please enter your company ID number followed by the # sign," then ENTER Company ID Number "1741" followed by the # sign.3.5. When prompted by the system, then VERIFY that the correct Company ID (1741) was entered and PRESS "9" 3.5.1. If the Company ID is not correct, then PRESS 6 3.5.2. When prompted by the system, then RE-ENTER Company Code 1741 followed by the "#" sign.0 Ll Li Li Li 3.6.When the System states, "Please enter your scenario activation password followed by the # sign," then ENTER the scenario activation password from the table below for the scenario, followed by the "#" button.On Site ERO Response ERO Response Required Required to Alternate Management Reporting Location for For Alert, Site Area, or Notification Only Security Events Station General Emergency, or Security Events with On Unusual Events excluding For Security Events with Site ERO reporting Security Events Off Site ERO reporting or*Optional for all other (HU1) other events as forsuall oethr determined by the Unusual Events Emergency Director Limerick Station 801 811 820 Oyster Creek 901 911 920 Peach Bottom 1001 1011 1020 TMI 1101 1111 1120 Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 12 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 3.7. When the system repeats the number just entered, then VERIFY the [-i number is correct and PRESS the "9" button for Yes.3.7.1. If the number is not correct, then PRESS "6" and RE-ENTER the 0 correct number.3.8. When the System states, "To start a scenario, enter the scenario ID LJ followed by the # sign or press # alone for more options," then ENTER the scenario number previously entered in Step 3.6, followed by the "#" button.3.9. When the system repeats the scenario number just entered, then VERIFY the number is correct and PRESS the "9" button for Yes.3.9.1. If the number is not correct, then PRESS "6" and RE-ENTER the L-i correct number.3.10. When the System states, "To Listen to the Current Scenario [0 Message Press 1, to Re-Record the Scenario Message press 2, to Start the Scenario Press 3, to Return to the Main Menu press#," then PRESS the "3" button.NOTE: The System will state, "The scenario is building." 3.11. When prompted, then PRESS the "#" button to exit. i-i 3.12. If the "Good-bye" prompt is not heard after the 2 nd attempt (the [i system was not successfully activated), then PROCEED to Section 5, Alternate Pager Notification Method.3.13. IF the system provides a voice prompt other than "Good-bye," then: 3.13.1. HANG UP the receiver.

Ll 3.13.2. WAIT five (5) seconds L3 3.13.3. REPEAT Steps 3.1 through 3.11 0i 3.14. When the system provides the prompt, "Good-bye," then HANG UP EL the receiver.Record the time of the call out system initiation:

Document Retention SPRS ID -5B.100 EP-AA-1 12-1 00-F-07 Revision F Page 13 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 3.15. If confirmation of the scenario activation is not verified via LI-I confirmation return phone call within approximately 10 minutes, then PROCEED to Section 5, Alternate Pager Notification Method.3.16. VERIFY that a call to the Control Room from the call out system is Ui received within 10 minutes of system initiation.

Record time of telephone call to the Control Room: 3.17. INFORM the Shift Emergency Director of the status of the call out LI system initiation 3.18. If an "Initial Qualifiers" report is not faxed to the Control Room within L1 20 minutes of activation, then PROCEED to Section 5, Alternate Pager Notification Method.3.19. INFORM the Shift Emergency Director of the status of the Call Out El System Initiation and EXIT this procedure Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 14 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 4.CALL OUT SYSTEM SCENARIO CANCELLATION 4.1.4.2.4.3.4.4.CIRCLE the station specific scenario number in step 4.4 below.DIAL the applicable designated toll free phone number to access either the primary or backup call out system.Primary System 1-877-486-6612 Backup System 1-800-308-8836 If the scenario is running on the backup call out system, then ENTER the "1741" company ID number, press the "#" button, and confirm your entry by pressing the "9" button when prompted, prior to proceeding to the next step.When the System states, "This is the remote activation module.Please enter your scenario activation password followed by the# sign," then ENTER the activation password from the table below for the scenario currently running, followed by the "#" button.El L)El L3 ERO Response to Site ERO Response Facilities Required Required to Alternate Reporting Location for For Alert, Site Area, or Management Security Events Station General Emergency, or Notification Only Security Events with On Unusual Events excluding For Security Events with Site ERO reporting Security Events (HU1) Off Site ERO reporting or*Optional fother events as nfor all other determined by the Unusual Events Emergency Director Limerick Station 801 811 820 Oyster Creek 901 911 920 Peach Bottom 1001 1011 1020 TMI 1101 1111 1120 Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 15 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 4.5. When the system repeats the number just entered, then VERIFY El that number is correct and PRESS the "9" button for Yes.4.6. When the System states, "To start a scenario, enter the scenario ID r-followed by the # sign or press # alone for more options," then ENTER the number previously entered in Step 4.4, followed by the"#" button.4.7. When the system repeats the number just entered, then VERIFY L3 that number is correct and PRESS the "9" button for Yes.4.8. When the System states, "The scenario is currently active. Would you L3 like to stop the scenario?

Press 9 for Yes or 6 for No," then Press the"9" button.NOTE, The system will state, "The scenario will be stopped", and return you to the Main Menu.4.9. When prompted by the system, then PRESS the "#" button to exit. EI 4.10. If you do not receive the "Good-bye" prompt and the voice prompts have ended, then: 4.10.1. HANG UP the phone. LI 4.10.2. WAIT five (5) seconds. 0I 4.10.3. REPEAT Steps 4.2 through 4.9. 0I 4.11. INFORM the Shift Emergency Director of the status of the Call Out L3 System Initiation and EXIT this procedure.

Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 16 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION 5.ALTERNATE PAGER NOTIFICATION METHOD 5.1. IF activation of both the primary and backup automated call out systems cannot be performed or verified successful, then NOTIFY Emergency Response Organization personnel by manually activating the pagers.5.1.1. CALL the appropriate pager numbers for the affected station and ENTER the respective code as the callback number, followed by the"#" button: Li Li LIMERICK EP Group Pager Number 1: (215) 363-7000-After Tone ENTER 8887961-After series of rapid beeps ENTER CODE followed by # sign EP Group Pager Number 2: (800) 224-9055-After Tone ENTER 5761-After series of rapid beeps ENTER CODE followed by # sign EP Group Pager Number 3: (215) 363- 7000-After Tone ENTER 8887646-After series of rapid beeps ENTER CODE followed by # sign EP Group Pager Number 4: (800) 224 7205-After Tone ENTER 5763-After series of rapid beeps ENTER CODE followed by # sign Nuclear Duty Officer: 800-307-0543 CODE: 6633 -ERO Response Required CODE: 6633 00 -Unusual Event CODE: 6633 55 -Alternate Reporting Location Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 17 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION PEACH BOTTOM EP Group Pager Number 1: 800-224-9403

-After hearing "Please enter the caller password" ENTER "5760-After series of beeps ENTER CODE followed by # sign EP Group Pager Number 2: 410-712-0710

-After Tone ENTER -4110101-After series of beeps ENTER CODE followed by # sign EP Group Pager Number 3: 215-363-7000

-After Tone ENTER -8887646-After series of beeps ENTER CODE followed by # sign EP Group Pager Number 4: 800-224-7205

-After hearing "Please enter the caller password" ENTER "5763-After series of beeps ENTER Code followed by # sign.Nuclear Duty Officer: 800-307-0543 CODE: 7733 -ERO Response Required CODE: 7733 00 -Unusual Event CODE: 7733 55 -Alternate Reporting Location TMI TMI Primary 9-213-8898

-After the "Please enter the caller password" voice prompt, ENTER the "5759" password-After the "Please leave your voice or numeric message after the tone" prompt, ENTER CODE followed by # sign.TMI Back-Up 9-1-800-241-7193

-After the "Please enter the caller password" voice prompt, ENTER the "5759" password-After the "Please leave your voice or numeric message after the tone" prompt, ENTER CODE followed by # sign.EOF-PA 9-1-215-363-7000

-After the single tone, ENTER the "8887646" password-After the rapid beeps, ENTER CODE followed by # sign.EOF-Backup 9-1-800-224-7205 (5763)-After the single tone, ENTER the "5763" password-After the rapid beeps, ENTER CODE followed by # sign.Nuclear Duty Officer: 800-307-0543 CODE: 8833 -ERO Response Required CODE: 8833 00 -Unusual Event CODE: 8833 55 -Alternate Reporting Location Document Retention SRRS ID -5B.100 EP-AA-1 12-1 00-F-07 Revision F Page 18 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Oyster Creek EP Group Pager Number 1: (800) 653-6918 CODE: 9933 -ERO Response-After Tone ENTER 5757 Required-After series of rapid beeps ENTER CODE CODE: 9933 00 -Unusual Event followed by # sign CODE: 9933 55 -Alternate Reporting EP Group Pager Number 2: (609) 391-3093 Location-After Tone ENTER 5757-After series of rapid beeps ENTER CODE followed by # sign Nuclear Duty Officer: 800-307-0543 Document Retention SRRS ID -51.100 Exeltn.Nuclear EP-AA-112-100-F-07 Revision F Page 19 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION This revision is a major rewrite; no revision bars are shown Attachment I -ERO Augmentation

-Limerick Page 1 of 3 Unusual Event Notme P-paed phone is Section 2 ERO Response to site.Lift receiver pres"Spe.aker" bctOr. 3 Press"Part 1 ERO Response Required'button Voice pcrompt Says: 'You s e te ed 801 to that coret?" Yes Na succ rsfuliess: "Part 2 Hng up. ERg Response Perfoee stepso Required" aaein. buttoe, If nae attempnt Is rot souccessful itite Proemed roiepromp atoate systep t o netso 3.tocd-bye" .Host up phone.SReccrd 3eitiotlc airerequrd It secccd attempt was not Successfct tim0 manualty activate epstema per EP-AA-t tS-1 55-P-07 Section 3.lorereuired."Po 'lice-iop ncs" tL2!chert.

0 Security Event ERO Response to alternate reporting location 0 Lift receiver 2L pr!ess Speoker" button. 0 Press"Part 1 Security Event" button Vorce prmrpt Says: ,YOc entered 820 to that correct?" Ye N *rs-- N press: ""Part 2 Haos up. Security Event" Perfone sreps btto..ainr. 0 U econd attempt is not successful then preceed Voice prompt to vest step, "Gocadytrye" Hang up phone.r0 niitime If second attempt was not successful

-0 1t1en manually activate system per EP-AA. I 12-100-PF-07 Section 3.D Folto-cy actions are retoired.Go to page 3"rollow.up actions" flowchort.

0 i Management Ltpressreevr

"Speaker" buttcn. 0 Press""Part 1 Management Notification Only" Onlc upreMy Pe Your s nteps Noed :to L]atepis tnat Corc?Press: "atI Management Notifiaop O N tft -byoe P buom teps Vicattempt i wsntsuccessful to Saut steas"Yourentered hunFolw-p phtone.RecordtIsihatio woo no succeotut ttreo Presast Perfomses Ntfcto USectonS.uton P0ucceopssfiue IOre reruired to ~ G tox pate S"P0 10 -o factien" activacte 0yte Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 20 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment 1 -ERO Augmentation

-Limerick Page 2 of 3 Alert Site Area Emergency General Emergency Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 21 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment I -ERO Augmentation

-Limerick Page 3 of 3 Follow-up Actions.Within -10 minutes of the initiation time, verify a call is returned from the.call out" system.Otherwise, manually activate the system per EP-AA-112-100-F-07 Section 3.Record time system returned the call: 0 Within minutes of the initiation time, verify an "Initial Qualifiers" fax is received.Otherwise, manually activate the system per EP-AA-1 12-100-F-07 Section 3.Document Retention SRRS ID -5B.100 Exelkn.Nuclear EP-AA-112-100-F-07 Revision F Page 22 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION This revision is a major rewrite; no revision bars are shown Attachment 2 -ERO Augmentation

-Oyster Creek Page 1 of 3 ManullyactiatePre-planned prxne is EP-AA-1,12-t DO-F-OP N ,, ivrcni S.ct.. 2 /I 'Yes ERO, Resos tstefacilities Lilt receiver"Speaker" Press"Part I ERO Response Required" buttont Security Event[ERO Response to alternate creporting location 0 Lift receiver presýS palrer" button. 0 Press"PartI Securityp Event" button 0 Management Notification Only Lift receiver go cress'Speaker" buttoir. 0 Press"Part 1 Management Notification Only" button is that c...e.t?'Yes Ne Htng up. ERO Response Perfom steps tRequired again. button 0 if second attempt is not successful law Proceed voice prompt t nt step. ays: C, 0000-tye" fang up phoune Record dnitation if second attempt was not successful MW0* manually activate system per EP-AA- 112-100-F-O7 Section 3.Follow-up actions are required.Go to page 3"Followrup actians" flowchart.

0 Voice Prom nays: ot '..yo°°ame\N> sh 920-N1 Hang up.Perforrm steps again.II necend attempt is not successful g=m proceed to nest step.0 11 second attempt was not successful then manually activate system pot EP-AA-112-f Ott-F-O7 Section 3.03 c/Yes Press: "Part 2! ° .pik... o Securit Enenitic Voice prompt says: Hang up pioner.Recess riniatiaton{3 Fullew-up acteons are required.Ge tp page 3 Fotlew-up ctions" ftowchart.

Document Retention SRRS ID -5B:100 EP-AA-112-100-F-07 Revision F Page 23 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment 2 -ERO Augmentation

-Oyster Creek Page 2 of 3 Alert Site Area Emergency General Emergency Yes / Yes is Functional?

O ~Securil ERO Manually activate Respi Response system per Alta To site EP-AA-112-100-F-07 repo facilities 0Section 2 Loc Liftpres recevor Lift prer S pr"Seaker" ... Sp button., Press Pr"Part 1 ..p ERO Response Required" Securat buttonh bu Voice prompt Voice ,stps t e quie d" "Oeru , 901 9 ae Is that correct" ae Is that No No Hans up. Pat2Hong up.Perform steps ERO Response Perform steps agi.Required" again.if Secoind buto f second attempt is not attempt is not successfulVoice promptsuccessful then proceed sthen proceed to snot sep'swa: to neot step, H a n g upp h o n e .e t o , [If second attempt If second attempt is not successful Is not successful thun manually Record Initiation tiAn manually actiate system time. actoatn system per per EP-AA-1 12-1 00-F-07 0 EP-AA-112-i100-F-07 Section 3. Section 3.00 Follow-up actions are required.Go to page 3"Follow-up actions" flowchart.

Ej I ty Event onseto mate inting ation o I krc ceiver ress 9'v ealter" tton. El ress art 1 y Event" fton prompt ys: entered 20.comaýt?" Yes Pre..Part 2 security Event" buttonr 0 Voice prompt says:-Good-bye" 1 Hang up phone.0 Record Initiatlon tinnei i Follow-up actions are required.Go to page 3-Folow-up actions" flowchart.

o Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 24 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment 2 -ERO Augmentation

-Oyster Creek Page 3 of 3 Follow-up Actions.0 Within -10 minutes of the initiation time, verify a call is returned from the"call out" system.Otherwise, manually activate the system per EP-AA-112-100-F-07 Section 3.0 Record time system returned the call: 1 Within minutes of the initiation time, verify an "Initial Qualifiers' fax is received.Otherwise, manually activate the system per EP-AA-112-100-F-07 Section 3.Document Retention SRRS ID -5B.100 Exelkn.Nuclear EP-AA-112-100-F-07 Revision F Page 25 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION This revision is a major rewrite; no revision bars are shown Attachment 3 -ERO Augmentation

-Peach Bottom Page 1 of 3 Manually antlvate system per P NO EP-AA-tI t2-105-F-07 Section 2 Pre-planned piote 10 funtiotnal?

7'Yes I ERO Response to site facilities Lifb receicer 9L press'Speaker'button.Press"Part 1 ERO Response Required" button 0/7 /-'\Voice ptompt says:."u etee' 1001 ~,,stat correc!t?>'

7 Yes T7 No F Pro-sg""Part 2 Hang up ERO Respe Pettormr steps Required again. button if secod attempt is not successful then proced Voice promi to nett step. says: Hang up phc Record Initial If second attempt was not successful then manually activate system per EP-AA-t 12.100-F-07 Section 3.0 I Security Event ERO Response to alternate reporting location o Lif receiver press"Speaker" button. 0 Press"Part 1 Security Event" button 0 Voice prom says:You ent-r",\ 1020 S"Is that coire Hang up.Perfortm steps it second attempt is not sucoc tful 11100 ptoceedi to neeot step.C)If second attempt was not succe.ssif thee manually activate system pet EP-AA- 112-100-F-07 Section 3.[3L-/npt t? Yes Press: ,'Part 2 Security Event" button.Voice prompt says: "Good-oye" Hang up phone.[Recordl nifiatioc.

Follow-up actions are qequired, Go to page 3 Follow.-up actions" lowchart.

o Management Notification Only Litt receiver 9r' press"Speaker" button. o Press"Part 1 Management Notification Only" button/ Voice prompt Press "0" Press: Part 2 Mana g ement Notification Only" Hang up. button. o Pearorm steps agai,.If second Voice prompt attiemp is not says: succesful

'Good-ye then tceed to nexl step. He oag p phone.1 2 Record initiation time: If second attempt was not successful then manually actiVate system per EP-AAt t12-100-F.07 Section 3.F-ort ow..pa. lions are required." oto pageo"Fo41wu ctos Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 26 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment 3 -ERO Augmentation

-Peach Bottom Page 2 of 3 Alert Site Area Emergency General Emergency Yes / Yes Pe-Programmed Phon ERO Response To site facilities 0 Lift receiver press"Speaker" butn 0 Press"Part 1 ERO Response Required" button Voice prompt says'.You entered 1001 Is that correct?" Ye No Press: "Part 2 Ha ng up. ERO Response Perform steps Required" agaion button £if second attempt is not 4r successful Voice prompt then ptoceed ys: to nest stepfl "Good-bye" s Hang up phoneJ If second attempt is not succestful then manually Record Initiation activate system time: per _______EP-AA-1 12-d100-F-t7 J Section 3.0 Follow-up actions are required.Go to page 3"Follow-up actions" flowchart.

0 Manually activate system per EP-AA-112-100-F-07 Section 2 Securit y EventI Response to Alternate reporting Location o]Lift receiver pssss Press o"Part 1 Security Event" button issfsl Har manual Scrdi nit actvat sytmsie Seton 0P r e s s " S ' , thett p ocPrdsas: Han Hapg Seurityne if second atmt.atep is eod ntain]successful V oi prompt Iare proceeed"Folnowup phtone.fo ha. 0 Attachment 3 -ERO Augmentation

-Peach Bottom Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 27 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Page 3 of 3 Follow-up Actions.0 Within -10 minutes of the initiation time, verify a call is returned from the"call out" system.Otherwise, manually activate the system per EP-AA- 112-100-F-07 Section 3.0 Record time system returned the call: Within minutes of the initiation time, verify an "Initial Qualifiers" fax is received.Otherwise, manually activate the system per EP-AA- 112-100-F-07 Section 3.Document Retention SRRS ID- 5B.100 Exekln.Nuclear EP-AA-112-100-F-07 Revision F Page 28 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION This revision is a major rewrite; no revision bars are shown Attachment 4 -ERO Augmentation

-Three Mile Island Page 1 of 3 Manually activate , P pan-nedphone is system poter EP-AAA1t2-100-F-07 Section2 2 I /I Yes ERO Response to site facilities Lift receiaer 21 press button.Press'Part 1 ERO Response Required" button CD 4,x I {3 Security Event ERO Response to alternate reporting location 0 Lift receiver at ,Sppress Speaker'button, 0 Press"Part 1 Security Event" button 03 Management Notification Only 0 Lift receiver button. 0 Press-Part I Management Notification Only" button 0 K No ranti up.Petrtstep again.11 sewnr attempt is no.u-:o."ed successful titan prci to ne step.It second atten wa. not sui --Jhen manualt activate syste per EP-AA- 112-100-Section 3.Voice prompt says: K hao entte a 1101 Is chat corrct? 7\,, ,/'Yes Press"" 0 Pressa: "Pa nt 2 Required" bunton 0 Voice prompt says: Hang up phone-0 Record tnitiatron time: pto fly F-07 0 _Follow-up actions are required.Go to page 3'Follow-up actions" tlowchatt 0l Fi Hatm Part.Petter.g 5su ahetni JI secor wtea s nt activate EP-AAct1 Sect Voice Prompt says."You entered 1120 p -i ,, Yen/.VPress*'"Part 2 Sup. Security Event" tn steps buttonf.it is not satul t step. s Hunt up phone.0 Record enitiatian time: o attempt successful 0 tanualty system 2-100-F-07 e3.01 FF.Tltow-p actanc Go to 'page 3"etlew-up actions" flotnutte I.' Voice pro/ sues: You ente Pertor steps Pettett steps nanin aftempt is not the r;oceed to nextstep, if second attempt was net successful then manually activate system per EP-AA-t 12-1t00-F-07 Section 3.Yd.q Chl?' Yes Press '9 nýPress M."Part 2 Management Notification Only" button, 0 Voice prompt Record ini.atios time: are required.Go to pate 3'Follow-up actions" feowchart.

Document Retention SRRS ID -5B.100 EP-AA-112-100-F-07 Revision F Page 29 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment 4 -ERO Augmentation

-Three Mile Island Page 2 of 3 Alert Site Area Emergency General Emergency Yes is Functional?

Manually activate Securll ERe system per Respt Response EP-AA-112-100-F-07 Alte To site Section 2 repc facilties Lo Loc Lift receiver Lift re apc press pr"Speaker" "Sbpu buttn. 0but Press oPr"Part I ERe Response Required" Securit button Clbu voice prompt voice says: sa You entered nYou 1101 if Is that correct?'

Yes Is that No .No S Press: "Part 2 Hang up. ERO Response Haag up.Perfor r steps Required" Performn steps again. again.If second btosecond atempt is not attempt is not successful succeossl liMo proceed Voice Prompt tita pr-ýceue d to nest step says: t etse.Stnep. "Good-bye" 0 to next stepD Hang op phone.J If second attempt If second attempt is not successful is not successful tlss maually Record Initiation iMta manually activate spstem time: activate system per per EP-AA-t I 2-100-F-07 J EP-AA- I12-100t-F-07 Section 3. Section 3.Follow-up actions are required.Go to page 3"Follow-up actions" flowchart.

o ty EventI onse to mate orting ation o`eiver eýaker" tnton. 0 ass art 1 tyEvent" tton Prompt lys: entered cret' Yes Press: "Part 2 Security Event" button.Voicesasprompt"Good-bye" Hang up phone.Follow-up actions are required.Go to page 3"Follow-up actions'Document Retention SRRS ID -5B. 100 EP-AA-112-100-F-07 Revision F Page 30 of 30 MID-ATLANTIC ERO NOTIFICATION OR AUGMENTATION Attachment 4 -ERO Augmentation

-Three Mile Island Page 3 of 3 Follow-up Actions.I F Within -10 minutes of the initiation time, verify a call is returned from the"call out" system.Otherwise, manually activate the system per EP-AA-112-100-F-07 Section 3.I Within minutes of the initiation time, verify an "Initial Qualifiers" fax is received.Otherwise, manually activate the system per EP-AA-112-100-F-07 Section 3.0 Document Retention SRRS ID -5B.100