ML082610221

From kanterella
Revision as of 10:08, 20 September 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
McGuire Nuclear Station, Unit 2, Inservice Inspection Report for End of Cycle 18 (EOC-18)
ML082610221
Person / Time
Site: Mcguire
Issue date: 07/09/2008
From: Brandi Hamilton
Duke Energy Carolinas, Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML082610221 (287)


Text

{{#Wiki_filter:BRUCE H HAMILTON Diuke Vice President E~nergy McGuire Nuclear Station Duke Energy Corporation MGO1 VP /12700 Hagers Ferry Road Huntersville, NC 28078 704-875-5333 704-875-4809 fax bhhamilton@duke-energy. com July 9, 2008 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001

SUBJECT:

Duke Energy Carolinas, LLC (Duke)McGuire Nuclear Station -Unit 2 Docket No. 50-370 Inservice Inspection Report Attached is the Inservice Inspection Report for the end of cycle 18 (EOC-1 8) refueling outage for McGuire Nuclear Station (MNS), Unit 2. Attachment No. 1 is the Inspection Report performed in accordance with the last outage of the First Inspection Period of the Third 10-Year Inservice Inspection Interval.Reportable Indications One reportable indication was found on 2RCHP-IN during the RT examination. Plan addenda 2MNS-034 was written to schedule one additional sample examination using ASME Section Xl, IWC-2430 requirements of the 1998 Edition of ASME Section Xl with the 2000 Addenda. The additional sample was scheduled and performed during EOC-1 8 and found to be acceptable. The-reportable indication found during the RT examination was repaired. No code surveillance inspections are required because the indication was repaired and found acceptable on 4-13-08.Section 4.4 of the attached report lists the limited examination item numbers. A relief request is under development and will be submitted to the NRC for review and approval to address weld limitations found during this outage.This letter and attachments do not contain any new NRC commitments. www. duke-ehergy corn U. S. Nuclear Regulatory Commission July 9, 2008 Page 2 Questions regarding the attached report may be directed to Kay L. Crane at (704) 875-4306.Bruce Hamilton U. S. Nuclear Regulatory Commission July 9, 2008 Page 3 L. A. Reyes, Regional Administrator U.S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St., SWW, Suite 23T85 Atlanta, GA 30303 John Stang U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Mail Code Washington, DC 20555-0001 Joe Brady NRC Senior Resident Inspector McGuire Nuclear Station U. S. Nuclear Regulatory Commission July 9, 2008 Page 4 bxc: EC050-ELL RGC File INSERVICE INSPECTION REPORT Duke Energy Carolinas McGuire Nuclear.Station Unit 2 Eighteenth Refueling Outage Ene.. . FORM NIS-1 OWNER'S REPORT FOR INSER VICE INSPECTIONS As required by the Provisions of the ASME Code Rules 1. Owner:Duke Enerav Carolinas, 526 S. Church St., Charlotte, NC 28201-1006 (Name and Address of Owner)2. Plant: McGuire Nuclear Station, 12700 Hager's Ferry Road Huntersville, N.C. 28078 (Name and Address of Plant)3. Plant Unit: 2 4. Owner Certificate of Authorization (if required) N/A 5. Commercial Service Date: March 1, 1984 6. National Board Number for Unit 84 7. Components Inspected: Component or Appurtenance Manufacturer or Manufacturer or Installer Installer Serial No.State or Province No.National Board No.See Section 1.1 in the Attached Report Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.Total number of pages contained in this report 282 FORM NIS-1 (Back)8. Examination Dates November 12, 2006 to April 13, 2008 d.. Inspection Period Identification:

10. Inspection Interval Identification:
11. Applicable Edition of Section XI 12. Date/ Revision of Inspection Plan: Second Period Third Interval 1998 Addenda 2000 June 20, 2006 /Revision 2 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 2.0, 3.0 and 6.0 14. Abstract of Results of Examinations and Tests.15. Abstract of Corrective Measures.See Section 4.0 and 6.0 See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date TxJ ( NtZ 2 z ___Signed Duke Energy Carolina's. Owner By4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina employed by

  • HSBCT have inspected the components described in this Owner's Report during the period November 12, 2006 to April 13, 2008 and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any mannerfor any personal injury or property damage or a loss of any kind arising from or connected with this inspection-- .,, --Commissions N.C. 1524 LN Inspe6tdr's Signature Date* Hartford Steam Boiler of Connecticut 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com National Board, State, Province, and Endorsements OWNER'S REPORT FOR INSER VICE INSPECTIONS MCGUIRE UNIT 2 2008 REFUELING OUTAGE 3 / EOC 18 (Third Interval)Plant Location:

McGuire Nuclear Station 12700 Hager's Ferry Road Huntersville, North Carolina 28078 -9340 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Document Completion Date: -Owner: Duke Energy Carolinas 526 South Church Street Charlotte, N.C. 28201-1006 Revision 0 Prepared By: Reviewed By: Approved By:~KVX~ ,N~f A~ C Date Date Date Co-[I- 200 F 2,5ý 66 DISTRIBUTION LIST 1. Duke Energy Carolinas Nuclear Technical Services Division Section XI Inspection Program Section 2. McGuire Inspection Services (ISI Coordinator)

3. NRC Document Control Desk 4. HSBCT (AIA)c/o ANII at McGuire 5. State of North Carolina Department of Labor c/o J. M. Givens, Jr.

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Third Ten-Year Interval Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owner's Report for Repair / Replacement Activities 0 6.0 Pressure Testing 0__1 1.0 General Information This report describes the Inservice Inspection of Duke Energy Carolina's McGuire Nuclear Station Unit 2 during Outage 3 / EOC18. This is the first Outage of the Second Inspection Period of the Third Ten-Year Interval. ASME Section XI, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performance of the ISI examinations. Included in this report are the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective action(s) taken when reportable conditions were found. In addition, there is an Owner's Report for the Repair / Replacement Section included for completed NIS-2 documentation of repairs and replacements. 1.1 Identification Numbers Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No. Province No. No.Reactor Vessel Rotterdam 30664 NC-201819 --Pressurizer Westinghouse 1491 NC-201818 W10285 Steam Generator 2A BWI 7700-02 NC-302674 159 Steam Generator 2B BWI 7700-04 NC-302675 161 Steam Generator 2C BWI 7700-01 NC-302676 158 Steam Generator 2D BWI 7700-03 NC-302677 160 Centrifugal Charging Pump Pacific Pumps 2A -48584 N/A 25 2B1- 48585 28 Containment Spray Heat Delta Southern Co. 2A-35005-73-3 NC-234203 3396 Exchanger Joseph Oat & (2B) 2514 NC-201822 5765 Sons, Inc.Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger _Letdown Heat Exchanger Joseph Oat & 2049-2B NC-201842 553 Sons, Inc.Reciprocating Charging Union Pump Co. N7210318-604 N/A N/A Pump I I I _ I McGuire Unit 2 Outage 3/EOC-18 Section 1 Page I of 5 Revision 0 June 11, 2008 1.1 Identification Numbers (Continued) Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No. Province No. No.2A 5-114E841 G02 Reactor Coolant Pump Westinghouse 2B 6-114E841 G02 N/A N/A 2C 7-114E841 G02 2D 8-114E841G02 Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator Reciprocating Charging Richmond Engineering N-2409.20 N/A 75220 Pump Suction Stabilizer Supply Co.Residual Heat Joseph Oat & Sons, Inc. 2A 2046-2C NC-1 69800 637 Removal Heat 2B 2046-2D NC-201823 638 Exchanger Safety Injection Pump Pacific Pumps 2A 49357 N/A 130 2B 49358 131 Regenerative Heat Joseph Oat & Sons, Inc. 2047-2B NC-201817 628 Exchanger 629 630 Seal Water Heat Atlas Industrial 1767 NC 201827 1549 Exchanger Manufacturing Company Seal Water AMF Cuno 2A -20 N/A 4364 Injection Filter 2B -22 4365 Main Steam Supply to Duke Power Co. SA N/A 62 Auxiliary Equipment System Containment Air Release Duke Power Co. VQ N/A 56 and Addition System Main Steam System Duke Power Co. SM N/A 70 Main Steam Vent to Duke Power Co. SV N/A 67 Atmosphere System Reactor Coolant System Duke Power Co. NC N/A 82 McGuire Unit 2 Outage 3/EOC-18 Section 1 Page 2 of 5 Revision 0 June 11, 2008 1.1 Identification Numbers (Continued) Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province No. Board No.Liquid Waste Recycle Duke Power Co. WL N/A 76 System Refueling Water System Duke Power Co. FW N/A 54 Auxiliary Feedwater Duke Power Co. CA N/A 73 System Residual Heat Removal Duke Power Co. I ND N/A 63 System .__ __Nuclear Service Water Duke Power Co. RN N/A 60 System Chemical & Volume Duke Power Co. NV N/A ,80 Control System ComponentCooling Duke Power Co. KC N/A , 78 System Main Feedwater System Duke Power Co. CF N/A 61 Containment Spray Duke Power Co. NS N/A 69 System Containment Ventilation Duke Power Co. RV N/A 72 Cooling Water System Safety Injection System Duke Power Co. NI N/A 83 Diesel Generator Engine Duke Power Co. KD N/A 47 Cooling Water System Spent Fuel Cooling Duke Power Co. KF N/A 81 System Diesel Generator Engine Duke Power Co. LD N/A 51 Lube Oil System Unit 2 Duke Power Co. N/A N/A 84 McGuire Unit 2 Outage 3/EOC-18 Section 1 Page 3 of 5 Revision 0 June 11, 2008 1.2 Personnel, Equipment and Material Certifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of the 1998 Edition of ASME Section XI with the 2000 addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section XI, Appendix VIII, and the 1998 Edition with the 2000 Addenda through the Performance Demonstration Initiative (PDI) for Supplements 2, 3, 4, 6, 8, and 10. Preservice examinations of weld overlays were conducted in accordance with Code Case N-504-2 including non-mandatory Appendix Q.The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e. NDE consumables) are on file at McGuire Nuclear Station or copies may be obtained by contacting Duke Energy Carolina's Corporate Office in Charlotte, North Carolina.The copies of the certification records for the Atlantic Group and the Washington Group International inspectors can be obtained by contacting Duke Energy Carolina's Corporate Office in Charlotte, North Carolina.1.3 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke's Corporate Office in Charlotte, North Carolina: 1 .Code Case N-460 (Applicable to items in this report where less than 100%coverage of the required weld examination volume was achieved.) These items are identified on Inspection Results that are located in Section 4.0 of this report.2. Problem Investigation Process M-07-0323 and M-08-1192 (Covers categorizing Containment Spray Heat Exchanger Support Lugs M2.D1.10.0023).

3. Problem Investigation Process M-08-2342 and M-08-3061 (Covers inspection discrepancies and limitation for hanger 2MCR-NC-4292 (M2.F1.10.0003).
4. Problem Investigation Process M-08-1705 (Covers rejectable indications and limitations on 2RCHP-IN (M2.R1.11.0279).

Addresses additional sample of 2RCHPSS-OUT-1 (M2.R1.11.0278).

5. RFR 03-002 (Class 1, 2 and 3 snubber examination under station technical ,specification)

McGuire Unit 2 Page 4 of 5 Outage 3/EOC-18 Revision 0 Section 1 June 11, 2008

6. RFR 01-005 (Risk Informed Inservice Inspection Program Submittal)
7. RFR 01-008 (Risk Informed ISI Alternative to Use VT-2 Instead of Volumetric Examination of Socket Welds)1.4 Augmented and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and / or record certification.

1.5 Responsible Inspection Aaencv B B m I Hartford Steam Boiler of Connecticut (HSBCT) is responsible for the third party inspections required by ASME Section XI.Authorized Nuclear Inservice Inspector(s) Name: , Employer: Business Address: J.F. Swan HSBCT 200 Ashford Center North Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com McGuire Unit 2 Outage 3/EOC-18 Section 1 Page 5 of 5 Revision 0 June 11, 2008 2.0 Third Ten-Year Interval Inspection Status The completion status of inspections required by the 1998 Edition of ASME Section XI with the 2000 addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1, 2 and 3 Component Supports.Augmented, Elective, and Risk Informed Inspections are also included.During the McGuire Third 10 Year Interval piping welds will be examined under the Risk Informed Inservice Inspection Program developed in accordance with methodology contained in the Westinghouse Owner's Group (WOG) Topical Report, WCAP-14572, Revision 1-NP-A. Request for Relief 01-005 was submitted to the NRC seeking approval to incorporate the Risk Informed Program into the Third 10 Year Interval ISI Plan for McGuire Unit 2. The NRC approved use of this program per SER dated June 12, 2002. Previous code examination Categories B-F, B-J, C-F-i, and C-F-2 will now be combined under the new Risk Informed Category R-A.Class 1 Inspections Examination Description Inspections Inspections Percentage 'Deferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 15 3 20.00% Yes in Reactor Vessel B-B Pressure Retaining Welds 5 1 20.00% No in Vessels Other than Reactor Vessel B-D Full Penetration Welded 36 10 27.77% Partial Nozzles in Vessels Inspection Program B Reference B-F Pressure Retaining Risk Dissimilar Metal Welds in Informed Vessel Nozzles Program R01. Items B-G-1 Pressure Retaining Bolting 241 89 36.92% Yes Greater than 2" in Diameter B-G-2 Pressure Retaining Bolting 22 8 36.36% No 2" and Less in Diameter I McGuire Unit 2 Outage 3/EOC-18 Section 2 Page 1 of 5 Revision 0 June 11, 2008 Class 1 Inspections (Continued) Examination Description Inspections Inspections Percentage I Deferral Category Required Completed Completed Allowed Reference B-J Pressure Retaining Welds Risk No in Piping Informed Program R01. Items B-K Welded Attachments for 6 4 66.66% No Vessels, Piping, Pumps and Valves B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings B-L-2 Pump Casings 1, 0 00.00% Yes B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in. 9 3 33.33% Yes Nominal Pipe Size B-N-1 Interior of Reactor Vessel 3 2 66.66% No B-N-2 Welded Core Support Structures and Interior 2 0 00.00% Yes Attachments to Reactor Vessel B-N-3 Removable Core Support 1 0. 00.00% Yes Structures B-O Pressure Retaining Welds 3 1 33.33% Yes in Control Rod Housings B-P All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components B-Q Steam Generator Tubing See Note below F-A Class 1 Component 58 26 44.82% No F01.010 Supports .(Code Case N-491)Note: Steam Generator Tubing is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and is not included in this report.McGuire Unit 2 Outage 3/EOC-18 Section 2 Page 2 of 5 Revision 0 June 11, 2008 1 Deferral of inspection to the end of the interval as allowed by ASME Section Xl Table IWB 2500-1.These examination categories are exempt from percentage requirements per IWB-2412 (a), Inspection Program B.Class 2 Inspections Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed C-A Pressure Retaining Welds 28 *3 *10.71% No in Pressure Vessels C-B Pressure Retaining Nozzle 11 5 45.45% No Welds in Vessels C-C Welded 'Attachments for 17 8 47.05% No Vessels, Piping, Pumps and Valves C-D Pressure Retaining Bolting -N/A N/A N/A N/A Greater Than 2" in Diameter Reference C-F-1 Pressure Retaining Welds Risk Informed in Austenitic Stainless Program R01.Steel or High Alloy Piping Items Reference C-F-2 Pressure Retaining Welds Risk Informed in Carbon or Low Alloy Program R01.Steel Piping Items C-G Pressure Retaining Welds 7 4 57.14% No in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 6.0 OF THIS Components REPORT F-A Class 2 Component 229 109 47.59% No Supports F01.020 (Code Case N-491)* Seven (7) welds were scheduled for examination in period one and three (3) were examined. The four (4) that were not examined were welds in the Regenerative Heat Exchanger. In previous intervals, relief from examination of these welds was granted based on hardship associated with radiation exposure. A similar relief request may be submitted for this interval or, alternatively, these welds may be eliminated from scope using Code Case N-706.McGuire Unit 2 Outage 3/EOC-18 Section 2 Page 3 of 5 Revision 0 June 11, 2008 Additional Component Support Examinations Class 1, 2 and 3 Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed F-A Supports other than Piping 42 22 52.38% No F01.040 Supports Class 1, 2 & 3 F-A Component Supports No F01.050 Snubbers Class 1, 2 & 3*Inspections to be performed per Relief Request 03-002 Risk Informed Inservice Inspection Program Class 1 and 2 Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed R-A Piping Examinations Class 89 37 41.57% No 1 and 2 Weld Overlay Section XI Appendix Q Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed M2.Q1.1 Weld Overlay 6 6 100% No Augmented I Elective Inspections Summary Description Percentage Complete Number M2.G1.1 Reactor Coolant Pump Flywheels 100% of Outage 3/EOC-18 Requirements Met M2.G2.1 RPV Closure Head Studs and Nuts per No examinations required for Outage 3/EOC-18 Nuclear Guide 1.65 M2.G3.1 Pipe Rupture Protection 100% of Outage 3/EOC-18 Requirements Met M2.G5.1 RPV Head Penetration Nozzles No examinations required for Outage 3/EOC-18 M2.G5.2 RPV Vent Line No examinations required for Outage 3/EOC-18 McGuire Unit 2 Outage 3/EOC-18 Section 2 Page 4 of 5 Revision 0 June 11, 2008 Augmented / Elective Inspections Continued Summary Description Percentage Complete Number M2.G6.2 Pressurizer Manway 100% of Outage 3/EOC-18 Requirements Met McGuire Unit 2 Outage 3/EOC-18 Section 2 Page 5 of 5 Revision 0 June 11, 2008 3.0 Final Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section XI Class 1, Class 2, Class 3 Augmented and Risk Informed examinations credited for this report period.The information shown below is a field description for the reporting format included in this section of the report:

SUMMARY

NUMBER ID NUMBER SYS ISO / DWG NUMBERS PROC INSP REQ MAT/ SCH DIA / THICK CAL BLOCKS COMMENTS= ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements = Unique Identification Number= Component System Identification -Location and / or Detail Drawings= Examination Procedures -Examination Technique -Magnetic Particle, Dye Penetrant, etc.= General Description of Material= Diameter / Thickness= Calibration Block Number= General and / or Detail Description McGuire Unit 2 Outage 3/EOC-18 Section 3 Page 1 of 1 Revision 0 June 11, 2008 DUKE ENEWW~NUCLEAR TECHNIC.i SERVICES Inservice Inspection Database Management System Plan Report ScheduleWorks ______McGuire 2, 3rd Interval, Outage 3 (EOC-18)This report includes all changes through addendum 2MNS-037 Summary Num Component ID / Type Insp System ISO/DWG Numbers Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / Historical Data Category AUG M2.G1.1. 0004 2RCP-2D NC MCM 1201.01-7 MC1201.01-7, MC-ISIN3-Class 1 2553-01.00 MCM 1201.01-0080 NDE-900 UT CS 0.000 / 0.000 G01.001.004, G01.001.004A REACTOR COOLANT PUMP FLYWHEEL Component AUGMENTED EXAMINATION. REFERENCE NRC LETTER DATED AUGUST 5, 2004 AMENDMENT NO. 205 TO RENEW FACILITY OPERATING LICENSE NPF-17. THIS AMENDMENT REVISES TS 5.5.7 REACTOR COOLANT PUMP FLYWHEEL INSPECTION PROGRAM TO INCREASE THE INSPECTION INTERVAL FROM 10 TO NOT EXCEED 20 YEARS. PER NOTE FROM STEVE ROSENAU DATED 10/29/2004 THE SCHEDULE IS AS FOLLOWS: 2RCP-2A WILL BE DONE 2EOC-24, LAST UT EXAM 3/28/1999 (ON 2A PUMP), 2RCP-2B WILL BE DONE 2EOC-22, LAST UT EXAM 1/1/1996 (ON 1D PUMP), 2RCP-2C WILL BE DONE 2EOC-24, LAST UT EXAM 9/23/1999 (ON 1C PUMP), 2RCP-2D WILL BE DONE 2EOC-24, LAST UT EXAM 6/10/1998 (ON 1 B PUMP) IT SHOULD BE NOTED THAT THE FLYWHEELS HAVE BEEN MOVED AROUND AND EXAMINATION DATE MAY NOT APPLY TO THE CURRENT PUMP LOCATION. THSES OUTAGES EXCEPT 2EOC-22 (3RD INTERVAL) WILL BE PART OF THE FOURTH INTERVAL AND THEY MUST BE INCLUDED WHEN THE ISI PLAN IS WRITTEN. NOTE: ANY REACTOR COOLANT PUMP REMOVED FROM SERVICE BEFORE THIS TIME SHOULD BE EXAMINED BEFORE REMOVAL, PSI DONE ON THE REPLACEMENT AND THE SCHEDULE WILL BE RECALCULATED FOR THE NEW 20 YEAR EXAMINATION DATE.2RCP-2D was examined EOC-1 8 (2008). The 20 year examination date will be rescheduled to start from this inspection date.Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10AM Page 1 of 19 Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28: 10 AM Page 1 of 19 This report includes all changes throvqh addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC-18)Summary Num Component ID / Type System ISO/DWG Numbers Insp Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / Historical Data Cateaobrv AUG M2.G3.1.0001 2NC2FW22-7 Circumferential NC MCFI-2NC22 Class 1 MC-ISIN3-2553-01.00 NDE-35 PT SS 1.000 / 10.000 G03.001.004, G03.001.004A AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). SEE SECTION 8 FOR CALIBRATION BLOCK REQUIREMENTS. Pipe to Elbow M2.G3.1.0001 2NC2FW22-7 Circumferential M2.G6.2.0001 2PZR-Manway NC MCFI-2NC22 MC-ISIN3-2553-01.00 Class 1 PDI-UT-2 UT SS 1.000 / 10.000 G03.001.004, G03.001.004A Component AUGMENTED EXAMINATION. REFERENCE PDI-UT-2-M DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). SEE SECTION 8 FOR CALIBRATION BLOCK REQUIREMENTS. Pipe to Elbow NC MCM 1201.01-140 Class 1 NDE-68 VT-2 Pressurizer Manway Diaphram Seal Weld. Bare Metal Visual Exam by VT-2 qualified Inspector. Examine the gap between the Pressurizer Manway Cover and Manway for evidence of diaphram plate seal weld leakage. (For responsible Individual, contact J.M. Shuping, Alloy 600 Engineer Nuclear Technical Services). Reference NRC Bulletin 2004-01.Pressurizer Manway Categorv B-D M2.B3.140.0005 2SGC-INLET Circumferential M2.B3.140.0006 2SGC-OUTLET Circumferential NC MCM 2201.01-0216 Class 1 MCM 2201.01-0207 NDE-680 UT CS 6.500 / 0.000 B03.140.005 50235 STEAM GENERATOR 2C INLET NOZZLE TO LOWER HEAD. Y1-X2 QUADRANT. (INSIDE RADIUS SECTION).Nozzle To Head B03.140.006 NC MCM 2201.01-0216 Class 1 MCM 2201.01-0207 NDE-680 UT CS 6.500 / 0.000 50235 STEAM GENERATOR 2C OUTLET NOZZLE TO LOWER HEAD. Y2-X2 QUADRANT.(INSIDE RADIUS SECTION).Nozzle To Head Printed 06/11/08GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 2 of 19 This report includes all changes throuqh addendum 2MNS-037 Summary Num Component ID / Type McGuire 2, 3rd Interval, ou.Insp Procedure Req Mat 3 (EOC-18)Sched Thick/Dia System ISO/DWG Numbers Cal Blocks Comments / Historical Data Category B-G-2 M2.B7.20.0001 B07.020.001 2PZR-MWB NC MCM 2201.01.015 NDE-62 VT-1 CS 7.500 / 1.875 PRESSURIZER MANAWAY BOLTING (16 Class 1 MC-ISIN-2553-02.00 BOLTS). EXAMINE ALL BOLTING MATERIAL.MCM 1201.01-0048 Bolting may be examined in place.M2.B7.50.0001 B07.050.001 2NC53-FL1 NC MCFI-2NC53 NDE-62 VT-i SS 8.000 /1.375 FLANGE BOLTING (12 STUDS). BOLT SIZE Class 1 MC-ISIN3-2553-02.00 DETERMINED USING MP/OIAI7650/01 ENCLOSURE 13.2. EXAMINE ALL fLANGE BOLTING MATERIAL. Bolting may be examined in place.M2.B7.50.0002 B07.050.002 2NC53-FL2 NC MCFI-2NC53 NDE-62 VT-1 SS 8.000 /1.375 FLANGE BOLTING (12 STUDS). BOLTING Class 1 MC-ISIN3-2553-02.00 SIZE DETERMINED USING MP/0/A/7650/01 ENCLOSURE 13.2. EXAMINE ALL FLANGE BOLTING MATERIAL. Bolting may be examined in place.M2.B7.50.0003 B07.050.003 2NC53-FL3 NC MCFI-2NC53 NDE-62 VT-1 SS 8.000 /1.375 FLANGE BOLTING (12 STUDS). BOLTING Class. 1 MC-ISIN3-2553-02.00 SIZE DETERMINED USING MP/O/A17650/01 ENCLOSURE 13.2. EXAMINE ALL FLANGE BOLTING MATERIAL. Bolting may be examined in place.Category B-K M2.1B10.10.0002 B1 0.010.002 2PZR-W13A NC MCM 2201.01-16 NDE-25 MT CS 4.000 /4.000 WELDED ATTACHMENT. PRESSURIZER Class 1 MC-ISIN3-2553-02.00 SEISMIC LUG TO SHELL. Y-Z QUADRANT. PT MCM 1201.01-0048 MAY BE USED IN PLACE OF MT IF NECESSARY SEISMIC LUG to SHELL M2.B10.10.0003 B10.010.003 2PZR-W13B NC MCM 2201.01-16 NDE-25 MT CS 4.000 /4.000 WELDED ATTACHMENT. PRESSURIZER Class 1 MC-ISIN3-2553-02.00 SEISMIC LUG TO SHELL. X-Y QUADRANT.MCM 1201.01-0048 PT may be used in place of MT if necessary. SEISMIC LUG to SHELL Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 3 of 19 This report includes all changes throuah addendum 2MNS-037 Summary Num Component ID / Type McGuire Z 3rd Interval, oui Insp System "ISO/DWG Numbers .Procedure Req Mat 3 (EOC-18)Sched Thick/Dia Cal Blocks Comments / Historical Data CaMegor5 E M2.1312.50.0-M-2 024 2N1-175 NI MCFI-2NI114 Class 1 MC-ISIN3-2562-03.01 MCM 1205.00-0005 NDE-64 VT-3 SS 0.000 / 6.000 B12.050.006E, B12.050.007E GROUP 7.6" CRANE-ALOYCO CHECK VALVE. INSPECT ONE OF THE FOLLOWING VALVES-IN GROUP 7: 2N1-126, 2N1-134, 2NI-852, 2NI-853, 2N1-175, 2N1-176, AND 2NI-181 ONLY IF DISASSEMBLED FOR MAINTENANCE, REPAIR, OR VOLUMETRIC EXAMINATION. Group 7 has been completed for the Third Interval M2.1312.50.0026 2N1-180 NI MCFI-2NI15 Class 1 MC-ISIN3-2562-03.01 MCM 1205.36-0028 NDE-64 VT-3 SS 0.000 / 6.000 Categorv B-N-1 M2.113.10.0001 2RPV-INTERIOR NC MCM 2201.01-0001 Class 1 MC-ISIN3-2553-01.00 NDE-63 VT-3 SS 0.000 / 0.000 B12.050.007A, B12.050.007G GROUP 8.6" WESTINGHOUSE SWING CHECK VALVE. INSPECT THE FOLLOWING VALVE IN GROUP 8: 2N1-180 ONLY IF DISASSEMBLED FORMAINTENANCE, REPAIR, OR VOLUMETRIC EXAMINATION. Group 8 has been completed for the Third Interval 613.010.001 REACTOR VESSEL INTERIOR. AREAS TO BE EXAMINED SHALL INCLUDE THE SPACES ABOVE AND BELOW THE REACTOR CORE THAT ARE MADE ACCESSIBLE FOR EXAMINATION BY REMOVAL OF COMPONENTS DURING NORMAL REFUELING OUTAGES. INSPECT EACHINSPECTION PERIOD.THIS EXAMINATION WAS PERFORMED FOR THE SECOND INTERVAL PER RFR03-004. EXAMINATION ALSO PERFORMED FOR 2EOC-16/OUTAGE 1, WILL REPORT BUT WILL NOT COUNT FOR PERCENTAGE PURPOSE. EXAMINATION WILL BE PERFORMED 2EOC-1 7/OUTAGE 2 AND WILL REPORT FOR PERCENTAGES AT THAT TIME.Category C-1B M2.C2.1 1.0005 2RCHPSS-INLET Circumferential NV MCM 1201.04-272 Class 2 MC-ISIN3-2554-03.00 NDE-35 PT SS 0.375 / 4.000 C02.011.001 RECIPROCATING CHARGING PUMP SUCTION STABLIZER. Inlet Nozzle to SHELL Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" McGuire 26/11/20087:28:10 AM Page 4 of 19 Printed 06/11/08GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 4 of 19 This report inctudes alt changes throuqh addendum 2MNS-037 Summary Num Component/D / Type Category C-B M2.C2.11.0006 2RCHPSS-OUTLET Circumferential Category C-C M2.C3.10.0008 2NSHX-SUPPORT-2B McGuire 2, 3rd Interval, ou.Insp Procedure Req Mat %3 (EOC-18)System ISO/DWG Numbers Sched Thick/Dia Cal Blocks Comments / Historical Data C02.011.002 NV MCM 1201.04-272 Class 2 MC-ISIN3-2554-03.00 NDE-35 PT SS 0.375 / 4.000 RECIPROCATING CHARGING PUMP SUCTION STABLIZER. Outlet Nozzle to SHELL C03.010.003 NS MCM 1201.06-0090 Class 2 MC-ISIN3-2563-01.00 MCM 1201.06-093 NDE-35 PT SS 0.750 / 0.000 Containment Spray Heat Exchanger 2B Support Welded Attachment. With Heat Exchangers 2A and 2B being manfactured by two different vendors using two different designs, we will examine both to meet Class 2 requirements. This surface exam will include the base metal and weld surfaces of the seismic lugs, stiffening ring (around the entire periphery of the heat exchanger), and heat exchanger exterior surface, including welds within the lug and stiffening ring, that lie within the surface examination boundaries shown in Figure IWC-2500-5. Reference PIPS M-07-00323, M-08-1192 and Work Request #947475.M2.C3.10.0009 2SWIF-SUPPORT-26 NV MGM 1201.04-27 Class 2 MC-ISIN3-2554-03.00 MC-1223-1 NDE-35 PT SS 0.375/ 0.000 C03.010.004 SEAL WATER INJECTION FILTER 2B SUPPORT. WELDED ATTACHMENT. M2.C3.20.0026 2MCA-NV-5647 Mech Snubber NV MCSRD-2ND-350/sht. 7 NDE-35 PT Class 2 MC-ISIN3-2554-03.01 2MCA-NV-5647 SS 0.125 / 8.000 C03.020.051 WELDED ATTACHMENT. INSPECT WITH M2.F1.20.0119. Mech Snubber Category C-G M2.C6.20.0029 2CF0026AB-1 Circumferential M2.C6.20.0047 2ND0070-1 Circumferential CF MCM 1205.23-0004 Class 2. MC-ISIN3-2591-01.01 NDE-35 PT CS 0.000 / 16.000 C06.020.001A ITEM # FWI-003. INSPECT ONE VALVE IN THIS GROUP (1A-1D) PER INTERVAL. PT may be used in place of MT if necessary. Valve Body To Valve Body ND MCM 2205.00-0005 Class 2 MC-ISIN3-2561-01.00 NDE-35 'PT SS 0.477 / 8.000 C06.020.004A ITEM # 9D-216. INSPECT ONE VALVE IN THIS GROUP (4A-4D) PER INTERVAL.Valve Body To Valve Body Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 611/2008 7:28:10 AM Page 5 of 19 This report includes all changes throuqh addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC-18)Summary Num_Component ID / Type Insp Procedure Req System ISO/DWG Numbers Mat Sched ThickWDia Cal Blocks Comments / Historical Data Cateoori D-A M2.D1.10.0022 2NDHX-SUPPORT-2A ND MCM 1201.06-22 Class 3 MC-ISIN3-2561-01.00 MCM 1201.06-48, MC 1220-32 NDE-65 VT-1 NA 0.750 / 0.000 2A RESIDUAL HEAT REMOVAL HEAT EXCHANGER SUPPORT WELDED ATTACHMENT. EXAMINE SEISMIC LUG AT TOP OF ND HEAT EXCHANGER 2A.EXAMINE WITH M2.F1.40.0074. REFERENCE PIP M-07-323.M2.D1 .10.0023 2NSHX-SUPPORT-2B NS MCM 1201.06-0090 Class 3 MC-ISIN3-2563-01.00 MC 1220-32, MC 1220-103 NDE-65 VT-1 NA 0.750 / 0.000 2B CONTAINMENT SPRAY HEAT EXCHANGER SUPPORT WELDED ATTACHMENT. EXAMINE WITH M2.F1.40.0080. SINCE "HX A" & "HX B" ARE OF DIFFERENT DESIGN, BOTH WILL BE EXAMINED. REFERENCE PIP M-07-323.Examine Welded Attachments, Support Lugs located on Class C side below the bottom Tube Sheet.The Seismic Lugs were visually examined EOC-18/Outage 3 under this Summary Number but have been re-categorized to Summary Number M2.C3.10.0008. M2.D1.10.0024 2NSHX-SUPPORT-2A NS MCM 1201.06-0025, MC Class 3 IWSA3-2563-01.00 NDE-65 VT-1 NA 0.750 / 0.000 MCM 1201.06-093, MC 1220-103 2A CONTAINMENT SPRAY HEAT EXCHANGER SUPPORT WELDED ATTACHMENT. EXAMINE SEISMIC TIE DOWN LUGS AT TOP OF NS HEAT EXCHANGER 2A. EXAMINE WITH M2.F1.40.0092. SINCE "HX A" & "HX B" ARE OF DIFFERENT DESIGN, BOTH WILL BE EXAMINED. REFERENCE PIP M-07-323.M2.D1.10.0026 2NSHX-SUPPORT-2A NS MCM 1201.06-0025, MC Class 3 094S§13-2563-01.00 NDE-65 VT-i1 NA 0.750 / 0.000 2A CONTAINMENT SPRAY HEAT EXCHANGER SUPPORT WELDED ATTACHMENT. EXAMINE SUPPORT LUGS AND RING. EXAMINE WITH M2.F1.40.0092. SINCE "HX A" & "HX B" ARE OF DIFFERENT DESIGN, BOTH WILL BE EXAMINED.MCM 1201.06-093, MC 1220-103 Category F-A M2.F1.10.0004 F01.010.004C 2MCR-NC-4293 NC MCSRD-2NC-203/sht. 1 NDE-66 VT-3 NA 0.000 /6.000 Mech Snubber Class 1 Mech Snubber Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM .Page 6 of 19 This report includes all changes throuqh addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC-18)Insp s Procedure Req Mat Sched Thick/Dia (Summary Num Component ID / Type System ISO/DWG Number'al Blocks Comments / Historical Data Category F-A M2.F1.10.0005 2MCR-NC-4289 Spring Hgr F01.010.005C NC MCSRD-2NC-203/sht. 1 Class 1 NDE-66 VT-3 NA 0.000 / 4.000 M2.F1.10.0040 2MCR-NV-4779 Spring Hgr Spring Hgr F01.010.101C NV MCSRD-2NV-204/sht. 1 NDE-66 VT-3 Class 1 NA 0.006 / 2.000 Spring Hgr M2.F1.10.0049 2MCR-NV-4380 Rigid Restraint F01.010.110B NV MCSRD-2NV-209/sht. 1 NDE-66 VT-3 Class 1 NA 0.000 /2.000 M2.F1.10.0142 2MCR-NI-4730 Rigid Support Rigid Restraint F01.010.092A, F01.010.6164 NI MCSRD-2NI-209/sht. 2 NDE-66 VT-3 Class 1 NA 0.000 / 2.000 Rigid Support M21F1.10.0161 F01.010.111A, F01.010.6202 2MCR-NV-4103 Rigid Support NV MCSRD-2NV-206/sht. 1 NDE-66 VT-3 Class 1 NA 0.000 / 2.000 M2.Fl.10.0178 Rigid Support F01.010.114C, F01.010.6233 2MCR-NV-4406 Mech Snubber M2.F1.20.0061 2MCR-NI-4026 Hyd Snubber NV MCSRD-2NV-204/sht. 1 Class 1 NI MCSRD-2NI-201/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 /4.000 Mech Snubber F01.020.154C NDE-66 VT-3 NA 0.000 / 6.000 Hyd Snubber M2.F1 .20.0062 2MCR-NI-4017 NI Mech Snubber Class 2 F01.020.155C MCSRD-2NI-201/sht. 2 NDE-66 VT-3 NA 0.000 / 6.000 Mech Snubber Printed 06/11/08 GJU8302 v,,01/19/08 SDQA Cat "C" McGuire 2 6111/2008 7:28:10 AM Page 7 of 19 This report includes all changes thro,,qh addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC-18)Summary Num Component ID / Type Cateao F-A Insp Procedure Req System ISO/DWG Numbers Mat Sched Thick/Dia Cal Blocks Comments /Historical Data M2.F1.20.0086 2MCR-NS-4516. Rigid Support M2.F1.20.0091 2MCR-NS-4616 Rigid Restraint M2.F1.20.0092 2MCR-NS-4614 Rigid Restraint F01.020.201A NS MCSRD-2NS-201/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 / 8.000 Rigid Support F01.020.2068 NS Class 2 MCSRD-2NS-203/sht. 1 NDE-66 VT-3 NA 0.000 /8.000 Rigid Restraint F01.020.207B NS Class 2 MCSRD-2NS-203/sht. 1 NDE-66 VT-3 NA 0.000 / 8.000 Rigid Restraint M2.F1.29.0095 2MCR-NS-4665 Rigid Restraint M2.F1.20.0096 2MCR-NS-4701 Rigid Restraint M2.F1.20.0097 2MCR-NS-4710 Rigid-Restraint M2.F1.20.0098 2MCR-NS-4715 Rigid Restraint M2.F1.20.0099 2MCR-NS-4759 Rigid Restraint F01.020.210A, F01.020.210B NS Class 2 MCSRD-2NS-204/sht. 1 NDE-66 VT-3 NA 0.000 /8.000 Rigid Restraint F01.020.211B -NS MCSRD-2NS-205/sht. 1 NDE-66 Class 2 VT-3 NA 0.000/ 8.000 Rigid Restraint F01.020.2128 NS MCSRD-2NS-205/sht. 1 Class 2 NDE-66 VT-3 NA 0.000/8.000 Rigid Restraint-FO1.020.2138 NS MCSRD-2NS-205/sht. 1 Class 2 NDE-66 VT-3 NA 0.000/8.000 Rigid Restraint F01.020.214B NS MCSRD-2NS-206/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 18.000 Rigid Restraint Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" McGuire 26/11/20087:28:10 AM Page 8 of 19 Printed 06/11/08GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 611112008 7:28i 10 AM Page 8 of 19 This report includes all changes throuah addendum 2MNS-037 Summary Num Component ID / Type McGuire 2, 3rd Interval, ou lnsp Procedure Req Mat 3 (EOC-18)System ISO/DWG Numbers Sched Thick/Dia Cal Blocks Comments Historical Data Categor F-A M2.F1.20.0100 2MCR-NS-4757 Rigid Support F01.020.215A NS MCSRD-2NS-206/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 / 8.000__________Rigid Support M2.F1.20.0101 2MCR-NS-4765 Rigid Restraint F01.020.216B NS MCSRD-2NS-206/sht. 1 Class 2 NDE-66 VT-3 NA 0.000/ 8.000 M2.F1.20.0102 2MCA-NS-5008 NS Rigid Restraint Class 2 M2.F1.20.0103 2MCA-NS-5102 NS Rigid Support Class 2 Rigid Restraint F01.020.2171 MCSRD-2NS-350/sht. 1 NDE-66 VT-3 NA 0.000/10.000 Rigid Restraint F01.020.21 8A MCSRD-2NS-351/sht. 1 NDE-66 VT-3 NA 0.000/ 10.000 Rigid Support M2.F1.20.0104 2MCA-NS-5107 Rigid Restraint F01.020.219B NS MCSRD-2NS-351/sht. 1 Class 2 NDE-66 V--3 NA 0.000/10.000 Rigid Restraint M2.F1.20.0105 2MCA-NS-5116 Rigid Support F01.020.220A NS MCSRD-2NS-351/sht. 1 Class 2 NDE-66 V--3 NA 0.000 /10.000 Rigid Support M2.F1.20.0106 2MCA-NS-5202 Rigid Support F01.020.221A NS MCSRD-2NS-352/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 / 10.000 Rigid Support M2.F1.20.0107 2MCA-NS-5260 Spring Hgr F01.020.222C NS MCSRD-2NS-352/sht. 1 Class 2 NDE&66 VT-3 NA 0.000 /10.000 Spring Hgr M2.F1.20.0117 2-MCA-S-NV-521 A Rigid Support F01.020.257A NV 2-MCA-S-NV-521-1 Class 2 NDE-66 VT-3 NA 0.000 /4.000 Rigid Support Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 9 of 19 This report includes all changes throuqh addendum 2MNS-037 Summary Num Component ID / Type Cateczor F-A M2.F1.20.0119 2MCA-NV-5647. Mech Snubber* McGuire 2, 3rd Interval, ou Insp Procedure Req Mat 3 (EOC-18)System ISO/DWG Numbers Sched ThickWDia Cal Blocks Comments I.Historical Data F01.020.259C NV MCSRD-2ND-350/sht. 7 Class 2 NDE-66 VT-3 NA 0.125 / 8.000 INSPECT WITH M2.C3.20.0026. Mech Snubber M2.F1.20.0120 2MCA-NV-7046 NV M Rigid Restraint Class 2 F01.020.2601 CSRD-2ND-350/sht. 7 NDE-66 VT-3 NA 0.000 / 8.000 Rigid Restraint M2.F17.20.0128 2MCR-NV-4101 NV M Rigid Support Class 2 M, 2 F01.020.268A flCSRD-2NV-206/sht. 1 VlC-ISIN3-2554-01 .00 MCR-NV-4101 NDE-66 VT-3 NA 0.600/ 2.000 M2.F1.20.0129 2MCR-NV-4576 Rigid Restraint M2.F1.20.0159 2MCR-RN-4537 Rigid Support Rigid Support F01.020.269B NV MCSRD-2NV-224/sht. 1 NDE-66 VT-3 Class 2 NA 0.000 /2.000 Rigid Restraint F01.020.350A, F01.020.351A RN MCSRD-2RN-203/sht. 1 NDE-66 Class 2 VT-3 NA 0.000 /6.000 Rigid Support M2.F1 .20.0160 F101.020.375A, F101.020.375B 2MCA-RV-5017 Rigid Support RV MCSRD-2RV-350/sht. 1 NDE-66 Class 2 VT-3 NA 0.000/ 12.000 Rigid Support M2.F1 .20.0171 F01.020.427C, F01.020.436C 2MCA-SM-H141 Hyd Snubber SM MCSRD-2SMA/sht. 3 Class 2 NDE-66 VT-3 NA 0.000 / 36.000 M2.F1 .20.0341 Hyd Snubber F01.020.129A, F01.020.6585 2MCA-ND-5910 Rigid Support ND MCSRD-2ND-350/sht. 2 NDE-66 VT-3 Class 2 NA 0.125 / 12.000 Rigid Support Printed 06/11/08GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28: 10 AM Page 10 of 19 This report includes all changes throuqh addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC.18)Insp System. ISO/DWG Numbers Procedure Req Mat Sched ThickWDia Cal Blocks Comments/ Historical Data Summary Num Component ID / Type Categor F-A M2.F1.20.0505 F0l .020.267A, FOI .020.6881 2MCA-NV-5002 Rigid Support NV MCSRD-2NV-350/sht. 2 NDE-66 VT-3 Class 2 NA 0.000 / 2.000 M2.11,20.0584 Rigid Support F01.020.266C, F01.020.7035 2MCA-NV-5302 Mech Snubber NV MCSRD-2NV-353/sht. 2 NDE-66 VT-3 Class 2 NA 0.000/4.000 Mech Snubber M2.F1.20.0705 F01.020.426A, F01.020.7223 2MCA-SM-H140 Rigid Support SM Class 2 MCSRD-2SMA/sht. 3 NDE-66 VT-3 NA 0.000 136.000 Rigid Support _________M2.Fl.20.0760 F01.020.478C, F01.020.7317 2MCA-SV-H6 Mec Snb/Spr Hgr M2.F1.20.0781 2MCR-CA-H168 Mec Snb/Spr Hgr M2.F1.20.0818 2MCR-NI-4034 Rigid Support SV Class 2 MCSRD-2SVA/sht: 1 NDE-66 VT-3 NA 0.000 / 6.000 Mec Snb/Spr Hgr F01.020.020C, F01.020.7358 CA Class 2 MCSRD-2CAO/sht. 1 NDE-66 VT-3 NA 0.000/6.000 Mec Snb/Spr Hgr F01.020.186A, F01.020.7433 NI MCSRD-2NI-203/sht. 1 NDE-66 VT-3 Class 2 NA 0.000 / 6.000 Rigid Support M2.F1.20.0862 F01 .020.185A, F01.020.7518 2MCR-NI-4561 NI MCSRD-2NI-203/sht. 1 NDE-66 VT-3 NA 0.125/6.000 Rigid Support Class 2 Rigid Support Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 11 of 19 This report includes all changes throuch addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC-18)Insp s Procedure Req Mat Sched Thick/Dia Summary Num Component ID / Type System ISOIDWG Number Cal Blocks Comments / Historical Data Catecjor F-A M2.FI .20.1001 FOl .020.256A, F01 .020.7805 2MCR-NV-4171 Rigid Support M2.F1.20.1002 2MCR-NV-4172 Rigid Support M2.F1.20.1011 2MCR-NV-4181 Rigid Support M2.F1.20.1013 2MCR-NV-4191 Rigid Support M2.F1.20.1180 2MCA-CA-H11 Rigid Support NV MCSRD-2NV-223/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 /S2.000 Rigid Support F01.020.258A, F01.020.7806 NV MCSRD-2NV-223/sht. 1 NDE-66 VT-3 Class 2 NA 0.000 / 2.000 Rigid Support F01.020.261A, F01.020.7823 NV MCSRD-2NV-223/sht. 2 Class 2 NDE-66 VT-3 NA 0.000 / 2.000 Rigid Support F01.020.262A, F01.020.7826 NV MCSRD-2NV-224/sht. 1 Class 2 NDE-66 VT-3 NA 0.000 / 2.000 Rigid Support_____ F01.020.012A CA MCSRD-2CAM/sht. 2 Class 2 NDE-66 VT-3 NA 0.125 / 4.000 Rigid Support M2.F1.30.0031 2MCA-KC-3332 Mech Snubber CI F01.030.062C KC MCSRD-2KC-351/sht. 5 ass 3 NDE-66 VT-3 NA 0.281 / 16.000 Mech Snubber M2.F1.30.0032 2MCA-KC-3078 Mec Snb/Spr Hgr M2.F1.30.0033 2MCA-KC-3030 Hyd Snubber FO1.030.063C KC MCSRD-2KC-351/sht. 6 Class 3 NDE-66 VT-3 NA 0.000 / 16.000 Mec Snb/Spr Hgr F01 .030.064C KC MCSRD-2KC-351/sht. 7 Class 3 NDE-66 VT-3 NA 0.000 / 20.000 Hyd Snubber Printed 06/11(08 GJU8302 v. 01/19/08 SDQA Cat "C" MoGuire 26/11/2008 7:28:10AM Page 12 of 19 Printed 06111108 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11 /2008 7:28: 10 AM Page 12 of ig This report includes all changes throuqh addendum 2MNS-037 Summary Num Component ID / Type Categqory F-A M2.F1.30.0034 2MCA-KC-3325 Rigid Support McGuire 2, 3rd Interval, ou Insp System ISOIDWG Numbers Procedure Req Mat 3 (EQC-18)Sched Thick/Dia Cal Blocks Comments / Historical Data F01 .030.065A KC MCSRD-2KC-351/sht. 7 Class 3 NDE-66 VT-3 NA 0.000 / 20.000 Rigid Support M2.F1.30.0035 2MCA-KC-3150 Rigid Support F01.030.066A KC MCSRD-2KC-358/sht. 1 Class 3 NDE-66 VT-3 NA 0.365 / 16.000 Rigid Support M2.F1.30.0036 2MCA-KC-3144 Rigid Support M2.F1.30.0037 2MCA-KC-3274 Rigid Support F01.030.067A KC MCSRD-2KC-358/sht. 2 Class 3 NDE-66 VT-3 NA 0.000 1 8.000 Rigid Support F01 .030.068A KC MCSRD-2KC-358/sht. 3 Class 3 NDE-66 VT-3 NA 0.000 / 8.000 Rigid Support M2.F1.30.0248 2MCA-KC-3011 Rigid Support M2.F1.30.0254 2MCA-KC-3020 Mech Snubber M2.F1.40.0005 2RCP-B-SUPPORT Rigid Restraint F01.030.072A, F01.030.8267 KC MCSRD-2KC-351/sht. 3 Class 3 NDE-66 VT-3 NA 0.000 /14.000 Rigid Support F01.030.075C, F01.030.8277 KC MCSRD-2KC-351/sht. 4 NDE-66 VT-3 Class 3 NA 0.000/16.000 Mech Snubber NC MC 1070-7, MC 1070-2 Class 1 MC-ISIN3-2553-01.00 MC-1 070-08-2, MC-1 070-17, MCM 2201.01-0084 NDE-66 VT-3 NA 0.000 / 0.000 F01.040.005, F01.040.005B REACTOR COOLANT PUMP 2B SUPPORT.EXAMINE SUPPORT COLUMNS AND LATERAL RESTRAINT. REFERENCE PIP M-07-323.Rigid Restraint Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 26/11/2008 7:28:10AM Page 13 of 19 Printed 06/11/08GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28: 10 AM Page 13 of 19 This report includes all changes throuqh addendum 2MNS-037 McGuire 2, 3rd Interval, ou 3 (EOC-18)Summary Num Component ID / Type Insp Procedure Req System ISOIDWG Numbers Mat Sched ThickWDia Cal Blocks Comments / Historical Data Category F M2.F1.40.00O

  • -A 73 2NDP-SUPPORT-2A Rigid Restraint M2.F1.40.0074 2NDHX-SUPPORT-2A Rigid Restraint ND MCM 1201.05-014, MC Class 2 KM(R3-2561-01.00 NDE-66 VT-3 NA 0.000 / 0.000 F0I.040.006B RESIDUAL HEAT REMOVAL 2A PUMP SUPPORT. EXAMINE HORIZONTAL RESTRAINT AND VERTICAL SUPPORT.REFERENCE PI M-07-323.MCM 1201.05-0048

_____Rigid Restraint F0l .040.0078 ND MCM 1201.06-22 Class 2 MC-ISIN3-2561-01.00 MCM 1201.06-48, MC 1220-32 NDE-66 VT-3 NA 0.750 / 0.000 2A RESIDUAL HEAT REMOVAL HEAT EXCHANGER SUPPORT. EXAMINE LOWER SUPPORT AND UPPER RESTRAINT. EXAMINE WITH M2.D1.10.0022. REFERENCE PIP M-07-323.M25F1.40.0075 Rigid Restraint F0l .040.0088 2NSP-SUPPORT-2A Rigid Restraint NS MC 1680-00, MCM Class 2 W-18104A3-01.00 NDE-66 VT-3 NA 0.000/ 0.000 CONTAINMENT SPRAY PUMP 2A SUPPORT.EXAMINE HORIZONTAL RESTRAINT AND VERTICAL SUPPORT. EOC--18 / OUTAGE 3 REINSPECTION OF SUPPORT TO INCLUDE LATERAL RESTRAINT. REFERENCE PIP M-07-323.MC 1220-74, MC 1690-014.01 Rigid Restraint M2.F1.40.0080 2NSHX-SUPPORT-2B Rigid Restraint F01.040.039B NS MCM 1201.06-0090 Class 2 MC-ISIN3-2563-01.00 MC 1220-32, MC 1220-103 NDE-66 VT-3 NA 0.750 / 0.000 2B CONTAINMENT SPRAY HEAT EXCHANGER SUPPORT. EXAMINE LOWER SUPPORT AND UPPER LATERAL RESTRAINTS. EXAMINE WITH M2.D1.10.0023. SINCE "HX A" & "HX B" ARE OF DIFFERENT DESIGN, BOTH WILL BE EXAMINED., EOC--18 / OUTAGE 3 REINSPECTION OF SUPPORT TO INCLUDE UPPER LATERAL RESTRAINTS. REFERENCE PIP M-07-323.M2.F1.40.0092 2NSHX-SUPPORT-2A NS MC Rigid Restraint Class 2 -M 1201.06-0025, MC`ASiJ3-2563-01.00 NDE-66 VT-3 NA 0.750 / 0.000 MCM 1201.06-093, MC 1220-103 F01.040.009B 2A CONTAINMENT SPRAY HEAT EXCHANGER SUPPORT. EXAMINE LOWER SUPPORT AND UPPER LATERAL RESTRAINTS. EXAMINE WITH M2.D1.10.0024. SINCE "HX A" & "HX B" ARE OF DIFFERENT DESIGN, BOTH WILL BE EXAMINED. EOC-18/ OUTAGE 3 REINSPECTION OF SUPPORT TO INCLUDE UPPER LATERAL RESTRAINTS. REFERENCE PIP M-07-323.Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" MoGuire 26(11(2008 7:28:10 AM Page 14 of 19 Printed 06111108 GJU8302 v. 01119108 SDQA Cat "C" McGuire 2 611112008 7ý28:10 AM Page 14 of 19 This report includes all changes throuqh addendum 2MNS-037 Summary Num Component ID / Type McGuire 2, 3rd Interval, ou 3 (EOC-18)Insp Procedure Req Mat Sched Thick/Dia System ISO/DWG Numbers Cal Blocks Comments / Historical Data Categor F-A M2.F1.40.0104 2SWIF-SUPPORT-2B NV Rigid Restraint Class 2 F01.040.017B MCM 1201.04-27 MC-ISIN3-2554-03.00 MC-1223-1 -NDE-66 VT-3 NA 0.375 / 0.000 SEAL WATER INJECTION FILTER 2B SUPPORT.______ _____Rigid Restraint M2.F1.40.0105 2NIP-SUPPORT-2B Rigid Restraint NI MCM 1201.05-454 Class 2 MC-ISIN3-2562-03.00 NDE-66 VT-3 NA 0.000 / 0.000 F01.040.018B SAFETY INJECTION PUMP 2B SUPPORT LEGS (4). REFERENCE MANUAL MCM 1201.05-280.v.! _________Rigid Restraint M2.F1.40.0106 2KFHX-SUPPORT-2A Rigid Restraint F01.040.019B FUEL POOL COOLING HX 2A SUPPORT.KF MCM 1201.06-0027 Class 3 MC-ISIN3-2570-01.01 MC-1220-32 NDE-66 VT-3 NA 0.250 / 0.000 Rigid Restraint M2.F1.40.0132 2CRDM-SUPPORT NC MCM 1201.13-23 Class 1 MCM 1201.13-24 MCM 1201.13-25 NDE-66 VT-3 NA 0.000 / 0.000 REACTOR VESSEL CRDM SEISMIC SUPPORT. EXAMINE TURN BUCKLE, ALTHOUGH NOT REQUIRED BY CODE (PER MARK PYNE AND KEVIN RHYNE) THE FRAME WILL BE VISUALLY EXAMINED AS A SUPPLEMENT TO THE TURN BUCKLE EXAM Categorv -M2.Q1 .1.0001 2NC2FW2-NW6 NC PDI-UT-8 UT 1.406 / 14.000 MCFI-2NC2 DE-13-AX-01 DE-1 3-CIRC-01 Class I Weld overlay installed under Code Case N-504-2 and inspected under Section XI Appendix Q as required by Reg. Guide 1.147. Alloy 600/82/182 weld with weld overlay Alloy 690/52/152. This weld overlay (2NC2FW2-NW6) covers welds 2PZR-W1SE and 2NC2FW2-3. 14 Inch Pressurizer Surge Nozzle Examine EOC-18 311/2008, then 25% of the overlay population isrequired to be examined every ten years.Weld (2PZR-W1SE) was previously scheduled for EOC-18 but not examined.(M2. R1. 11.0035).Weld overlay Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 26/11/2008 7:28:10AM Page 15 of 19 Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C"-McGuire 2 6/11/2008 7:28:10 AM Page 15 of 19 This report includes all changes throtuh addendum 2MNS-037 McGuire 2, 3rd intervaf, ou, 3 (EOC-18)Summary Num Component ID / Type System ISO/DWG Numbers Insp Procedure Req Mat Sched ThickWDia Cal Blocks Comments / Historical Data Cateor Q-A M2.Q1.1.0002 2NC2FW61 -NW4 NC PDI-UT-8 UT 0.719 / 6.000 DE-8-AX-01 DE-8-CIRC-01 MCFI-2NC61 Class 1 Weld overlay installed under Code Case N-504-2 and inspected under Section Xl Appendix Q as required by Reg. Guide 1.147. Alloy 600/82/182 weld with weld overlay Alloy 690/52/152. This weld overlay (2NC2FW6 1-NW4) covers welds 2PZR-W3SE and 2NC2FW61-1. 6 Inch Pressurizer Relief Nozzle. Examine EOC-18 3/1/2008, then 25%,of the overlay population is required to be examined every ten years.____ Weld overlay M2.Q1.1.0003 2NC2FW53-NW1 NC PDI-UT-8 UT 0.719) 6.000 DE-8-AX-01 DE-8-CIRC-01 MCFI-2NC53 Class 1 Weld overlay installed under Code Case N-504-2 and inspected under Section Xl Appendix Q as required by Reg. Guide 1.147. Alloy 600/82/182 weld with weld overlay Alloy 690/52/152. This weld overlay (2NC2FW53-NW1) covers welds 2PZR-W4ASE and 2NC2FW53-12. 6 Inch Pressurizer Safety Nozzle. Examine EOC-18 3/1/2008, then 25%of the overlay population is required to be examined every ten years.Weld overlay M2.QI .1.0004 2NC2FW53-NW2 NC PDI-UT-8 UT 0.719 / 6.000 DE-8-AX-01 DE-8-CIRC-01 MCFI-2NC53 Class 1 Weld overlay installed under Code Case N-504-2 and inspected under Section Xl Appendix Q as required by Reg. Guide 1.147. Alloy 600/82/182 weld with weld overlay Alloy 690/52/152. This weld overlay (2NC2FW53-- NW2) covers welds 2PZR-W4BSE and 2NC2FW53-26. 6 Inch Pressurizer Safety Nozzle. Examine EOC-18 3/1/2008, then 25%of the overlay population is required to be examined every ten years.Weld overlay Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 26/11/20087:28:10 AM Page 16 of 19 Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/1112008 7:28: 10 AM Page 16 of 19 This report includes all changes throuclh addendum 2MNS-037 Summary Num Component ID / Type McGuire 2, 3rd Interval, ou Insp Procedure Req Mat 3 (EOC-18)System ISOIDWG Numbers Sched Thick/Dia Cal Blocks Comments / Historical Data Categor -A M2.Q1 .1.0O5 2NC2FW53-NW3 NC PDI-UT-8 UT MCFI-2NC53 Class 1 0.719 / 6.000 DE-8-AX-01 Weld overlay installed under Code Case N-504-DE-8-CIRC-01 2 and inspected under Section Xi Appendix Q as required by Reg. Guide 1.147. Alloy 600/82/182 weld with weld overlay Alloy 690/52/152. This weld overlay (2NC2FW53-NW3) covers welds 2PZR-W4CSE and 2NC2FW53-13. 6 Inch Pressurizer Safety Nozzle. Examine EOC-18 3/1/2008, then 25%of the overlay population is required to be examined every ten years.Weld overlay M2.Q1.1.0006 2NC2FW13-NW5 NC PDI-UT-8 UT MCFI-2NC13 0.531 / 4.000 DE-6-AX-01 DE-6-CIRC-01 DE-8-CIRC-01 Class 1 Weld overlay installed under Code Case N-504-2 and inspected under Section Xl Appendix Q as required by Reg. Guide 1.147. Alloy 600/82/182 weld with weld overlay Alloy 690/52/152. This weld overlay (2NC2FW13-NW5) covers welds 2PZR-W2SE and 2NC2FW13-1. 4 Inch Pressurizer Spray Nozzle. Examine EOC-18 3/1/2008, then 25%of the overlay population is required to be examined every ten years.Weld (2PZR-W2SE) was previously scheduled and examined in EOC-17 (RO1.011.022) Weld overlay Categor R-A M2.R1.11.0143 2NV2F-84 Circumferential Risk Segment NV-002AB R01.011.1007 NV MCFI-2NV1 Class 2 MC-ISIN-2554-03.01 NDE-12 RT SS 0.134 / 6.000 This weld was changed from 2NVP31-2 so RT could be performed on a weld in this segment.Elbow to Pipe M2.R1.11.0189 2NV2FW1 15-5 Circumferential Risk Segment NV-002AA R01.011.1014 NV MCFI-2NV1 15 Class 2 MC-ISIN-2554-03.01 NDE-12 RT SS 0.148 / 8.000 Pipe to Elbow Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 26/11/20087:28:10 AM Page 17 of 19 Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 17 of 19 This report includes all changes throucih addendum 2MNS-037 Summary Num Component ID / Type McGuire 2, 3rd Interval, oA, Insp Procedure Req Mat 3 (EOC-18)System ISO/DWG Numbers Sched Thick/Dia Cal Blocks Comments / Historical Data Cate gor_ R-A M2.R1.1 1.0275 2NV2FW215-48 Circumferential NV MCFI-2NV215 MC-ISIN-2554-01.02 Class 2 NDE-600 UT SS 0.344 / 2.000 Risk Segment NV-083 R01.011.152 SEE SECTION 8 FOR CALIBRATION BLOCK REQUIREMENTS. Component Pipe To Pipe M2.R1. 11.0278 2RCHPSS-OUT-1 Circumferential Risk Segment NV-1 08A R01.01 1. 155 NV MCFI-2NV32 Class 2 MC-ISIN-2554-03.00 MCM1201.04-0272 PDI-UT-2 UT SS 0.237 / 4.000 PDI-UT-2-M RECIPROCATING CHARGING PUMP SUCTION STABILIZER. Equipment

  1. 2NVAC0052.

EOC-18 examination performed as additional sample for indication found on Summary Number M2.R1.11.0279. Reference PIP M-08-01705. Terminal End Nozzle to Flange M2.R1.1 1.0279 2RCHP-IN Circumferential NV MCM 2201.05-0031 001 -NDE-12 Class 2 MC-ISIN3-2554-03.00 RT SS 0.237 /4.000 Risk Segment NV-108A R01.011.156 RECIPROCATING CHARGING PUMP INLET.SEE SECTION 8 FOR CALIBRATION BLOCK REQUIREMENTS. Pump flange bolting must be removed before examination can be performed. Terminal End M2.R1.11.0463 2NS2F427 Circumferential M2.R1.11.1534 2NV2FW1 15-4 Circumferential Flange to Pump Risk Segment NS-020 R01.01 1104 NS MCFI-2NS17 Class 2 MC-ISIN-2563-01.00 NDE-12 RT SS 0.148 / 8.000 Elbow To Pipe Risk Segment NV-002AA R01.01 1. 127 NV MCFI-2NV1 15 Class 2 MC-ISIN-2554-03.01 NDE-12 RT SS 0.148 / 8.000 Elbow to Pipe M2.R1.11.1536 2NVP8-3 Circumferential Risk Segment NV-002AB R01.011.129 NV MCFI-2NV1 Class 2 MC-ISIN-2554-03.01 NDE-12 RT SS 0.134 / 6.000 Pipe to Elbow Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" McGuire 26/11/2008 7:28:10AM Page 18 of 19 Printed 06/11/08 GJU8302 v.01/19/08 SDOA Cat "C" McGuire 2 6/11/2008 7:28:10 AM Page 18 of 19 This report includes all changes throtnh addendum 2MNS-037 McGuire 2, 3rd Interval, ot 3 (EOC-18)Insp s Procedure Req Mat Sched Thick/Dia Summary Num Component ID / Type System ISO/DWG Number'al Blocks Comments / Historical Data Catego R-A M2.Ri.11.1594 2NV2FW215-37 Circumferential NV MCFI-2NV215 MC-ISIN-2554-01.02 Class 2 NDE-600 UT SS 0.438 / 3.000 Risk Segment NV-080A R01.011.147 SEE SECTION 8 FOR CALIBRATION BLOCK Component REQUIREMENTS. Pipe To Tee M2.R1.11.1598 2NV2FW215-49 Circumferential NV MCFI-2NV215 MC-ISIN-2554-01.02 Class 2 NDE-600 UT SS 0.344 / 2.000 Risk Segment NV-083 R01.011.151 SEE SECTION 8 FOR CALIBRATION BLOCK Component REQUIREMENTS. ____ __________________Pipe To Pipe M2.R1.13.0002 2RV2FW30-27 Circumferential RV MCFI-2RV30 Class 2 MC-ISIN-2604-03.00 NDE-946 UT CS 0.375 / 12.000 Risk Segment RV-002 R01.013.002 StepWedge EXAMINE A 1 FT. LENGTH OF PIPE AT WELD TO DETERMINE WALL THKS. EXAMINE 6 INCHES EACH SIDE OF WELD, MARK IN 1 INCH GRID Pipe To Flange End of Report STATISTICS ONLY Class 1 30 Class 2 64 Class 3 14 Total by Class 108 Systems 108 Total Count 108 Printed 06/11/08 GJU8302 v. 01/19/08 SDQA Cat 'C" McGuire 26/11/20087:28:10 AM Page 19 of 19 Printed 06/11/08 GJU8302 v.01/19/08 SDQA Cat "C" McGuire 2 6/11/2008 7:28: 10 AM Page 19 of 19 4.0 Results of Inspections Performed The results of each examination shown in the Inspection Results (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.The information shown below is a field description for the reporting format included in this section of the report:

SUMMARY

NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF (Geometric Reflector applies only to UT)RFR (Relief Request)COMMENTS= ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2), Augmented Requirements -Unique Identification Number= Component System Identification -Date of Examination CLR Clear REC Recordable REP Reportable = Indicates inspection was limited.Coverage obtained is listed.SY Yes N No SY Yes N No= General and / or Detail Description McGuire Unit 2 Outage 3/EOC-18 Section 4 Page 1 of 3 Revision 0 June 11, 2008 Scheduleworks DUKE ENERG V CORPORATION QUALITY ASSURANC TECHNICAL SERVICES Inservice Inspection Database Management System Inspection Results McGuire 2, 3rd Interval, Outage 3 (EOC-18)Inspection Results for McGuire Unit 2 EOC-18 Insp System Date Insp Insp Status Limited Geo Ref RFR Comment Summary No Component ID M2.B10.10.0002 2PZR-W13A M2.B10.10.0003 2PZR-W13B NC NC 03/17/08 03/17/08 CLR REC N N N N N N MT-08-001 MT-08-002 Linear Indication acceptable per ASME Section XI Table IWB-3510-3 NI 03/12/08 CLR N M2.B12.50.0024 2N1-175 M2.B12.50.0026 2N1-180 M2.B13.10.0001 2RPV-INTERIOR M2.B3.140.0005 2SGC-INLET M2.B3.140.0006 2SGC-OUTLET M2.B7.20.0001 2PZR-MWB M2.17.50.0001 2NC53-FL1 M2.B7.50.0002 2NC53-FL2 M2.B7.50.0003 2NC53-FL3 N N VT-08-066 NI 03/13/08 CLR N NC 03/23/08 CLR N NC 03/14/08 CLR N NC 03/14/08 CLR IT NC 03/13/08 CLR N N N N N N N N N N N VT-08-063 VT-08-071 UT-08-008 UT-08-007 VT-08-065 NC 03/06/08 NC 03/06/08 NC 03/08/08 CLR CLR CLR N N N N N N N VT-08-068 N VT-08-069 N VT-08-070 M2.C2.11.0005 2RCHPSS-INLET NV 02/27/08 CLR N N N PT-08-003 Printed 6/11/2008 1:12:06 PM GJU8302 v.01/01/08 SDQA Cat "C" McGuire2 6/11/2008 1:11:05 PM Page 1 of 9 Printed 6/11/2008 1:12:06 PM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM Page 1of9 Inspection Results for McGuire Unit 2 EOC-18 Insp Insp Insp System Date Status Limited Summary No Component ID Ref RFR Comment M2.C2.11.0006 2RCHPSS-(M2.C3.10.0008 2NSHX-SUF M2.C3.10.0009 2SWIF-SUP M2.C3.20.0026 2MCA-NV-5 M2.C6.20.0029 -2CF0026AB M2.C6.20.0047 2ND0070-1 M2.D1.10.0022 2NDHX-SUF M2.D1.10.0023 2NSHX-SUF)UTLET NV 02/26/08 CLR N N N PT-08-001 PPORT-2B NS 03/26/08 CLR N N N PT-08-008NV 03/21/08 CLR N N N PT-08-006 647 NV 03/25/08 CLR N N N PT-08-007 CF 03/18/08 CLR N N N PT-08-005 ND 02/26/08 CLR N N N PT-08-002 PPORT-2A ND 02/25/08 CLR N N N VT-08-022 PPORT-2B NS 01/31/08 CLR N N N VT-08-023 The Seismic Lugs were visually examined EOC-1 8/Outage 3 under this Summary Number, this item has been re-categorized to Summary Number M2.C3.10.0008. Reference PIPs M-07-0323, M-08-01192 and Work Request 947475.PPORT-2A NS 01/31/08 CLR N N N VT-08-021 PPORT-2A NS 03/25/08 CLR N N N VT-08-075 4292 NC 03/04/08 REC 98.00% N N VT-08-079 This item was rescheduled from Outage 3/EOC-18 to Outage 4/EOC-19, new support must be selected to replace this support due to examination being limited at 98% coverage. Reference PIPs M-08-2342 and M-08-03061. M2.D1.10.0024 2NSHX-SUF M2.D1.10.0026 2NSHX-SUF M2.F1.10.0003 2MCR-NC-4 Printed 6/11/2008 1:12:07 PM GJUB302 v. 01/01/08 ge 2 of 9 Printed 6/11/2008 1:12:07 PM GJU8302 v.01/01/08 SDQA Cat 'C" McGuire2 6/11/2008 1:11:05 PM p. ~ge 2 of 9 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM P. Summary No M2.F1.10.0004 M2.F1.10.0005 M2.F1.10.0040 Inspection Results for McGuire Unit 2 EOC-18 Insp Insp Insp jo Component ID System Date Status Limited Ref RFR Comment 2MCR-NC-4293 NC 04/02/08 CLR N N N VT-08-078 2MCR-NC-4289 NC 03/05/08 REC N N N VT-08-035 Hanger acceptable for continued service, no operability concer for this support.Chain hoist removed from support 2MCR-NV-4779 NV 03/05/08. CLR N N N VT-08-036 M2.F1.10.0049 2MCR-NV-4380 M2.F1.10.0142 2MCR-NI-4730 M2.F1.10.0161 2MCR-NV-4103 M2.Fl.10.0178 2MCR-NV-4406 M2.Fl.20.0061 2MCR-NI-4026 M2.F1.20.0062 2MCR-NI-4017 M2.F1.20.0086 2MCR-NS-4516 M2.F1.20.0091 2MCR-NS-4616 M2-F1 .20.0092 2MCR-NS-4614 M2.F1.20.0095 2MCR-NS-4665 M2.F1.20.0096 2MCR-NS-4701 NV NI NV NV NI NI NS NS NS NS NS 03/05/08 03/05/08 03/05/08 03/05/08 03/05/08 03/05/08 03/05/08 03/05/08 03/05/08 03/05/08 03/03/08 CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR N N N N N N N N N N VT-08-037 VT-08-038 VT-08-039 VT-08-040 VT-08-042 VT-08-043 VT-08-051 VT-08-052 VT-08-053 VT-08-054 N N VT-08-055 Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM Page 3 of 9 Inspection Results for McGuire Unit 2 EOC-18 Insp System Date Insp Insp Status Limited Summary No M2.F1.20.0097 M2.F, .20.00.98 M2.F1.20.0099 M2.F1.20.0100 M2.F1.20.0101 M2.F1.20.0102 M2.F1.20.0103 M2.Fl.20.0104 M25F1.20.0105 M2.Fl.20.0106 M2.F1.20.0107 M2.Fl.20.0117 Component ID 2MCR-NS-471 0.do Ref RFR Comment NS 03/03/08 CLR 2MCR-NS-4715 NS 2MCR-NS-4759 NS 2MCR-NS-4757 NS 2MCR-NS-4765 NS 2MCA-NS-5008 NS 2MCA-NS-5102 NS 2MCA-NS-5107 NS 2MCA-NS-5116 NS 2MCA-NS-5202 NS 2MCA-NS-5260 NS 2-MCA-S-NV-521-1-A NV 03/05/08 03/03/08 03/03/08 03/03/08 02/07/08 02/07/08 02/07/08 02/06/08 02/05/08 02/05/08 CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR N N N VT-08-056 N N %VT-08-057 N N VT-08-058 N N VT-08-059 N N VT-08-060 N N VT-08-002 N N VT-08-073 N N VT-08-009 N N VT-08-031 N N VT-08-032 N N VT-08-003 N N VT-08-020 N N VT-08-013 N N VT-08-016 N 02/05/08 CLR N M2.F1.20.0119 2MCA-NV-5647 M2.F1.20.0120 2MCA-NV-7046 NV NV 02/07/08 CLR N 02/07/08 CLR N Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM Page 4 of 9 Inspection Results for McGuire Unit 2 EOC-18 Insp Insp Insp System Date Status Limited Summary No Component ID Ref RFR Comment M2.F1.20.0128 2MCR-NV-4101 M2.F1-.20.0129 2MCR-NV-4576 M2.F1.20.0159 2MCR-RN-4537 M2.Fl.20.0160 2MCA-RV-5017 M2.F1.20.0171 2MCA-SM-H141 M2.Fl.20.0341 2MCA-ND-5910 M2.F1.20.0505 2MCA-NV-5002 M2.Fl.20.0584 2MCA-NV-5302 M2.F1.20.0705 2MCA-SM-H 140 M2.F1.20.0760 2MCA-SV-H6 M2.Fl.20.0781 2MCR-CA-H168 NV 03/04/08 CLR N N NV 03/05/08 CLR N N RN 03/05/08 CLR N N RV 02/07/08 CLR N N SM 02/06/08 CLR N N ND 02/07/08 CLR N N NV 02/05/08 CLR N N NV 02/05/08 CLR N N SM 02/06/08 CLR N N SV 02/06/08 CLR N N CA 03/05/08 CLR N N N VT-08-044 N VT-08-045 N VT-08-067 N VT-08-017 N VT-08-019 N VT-08-015 N VT-08-006 N VT-08-010 N VT-08-018 N VT-08-001 N VT-08-041 M2.F1.20.0818 2MCR-NI-4034 NI 03/05/08 REC N N N VT-08-080 Welds on shim plate were broken, WO 01804236-01 repaired the shim plate.Attachment 301 statement states hanger acceptable for continued service.N N N VT-08-046 N N N VT-08-047 M2.F1.20.0862 2MCR-NI-4561 NI 03/05/08 M2.F1.20.1001 2MCR-NV-4171 NV 03/04/08 Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 CLR CLR SDOA Cat "C" SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM Page 5 of 9 McGuire 2 6/11/2008 1:11:05 PM Page 5 of 9 Inspection Results for McGuire Unit 2 EOC-18)nsp Insp Insp jo Summary No Component ID System Date Status Limited Ref RFR Comment M2.F1.20.1002 2M.R-NV-4172 NV 03/04/08 CLR N N N VT.08-048 M2.F1.20.1011 2MCR-NV-4181 NV 03/05/08 CLR N N N VT-08-049 M2.Fl.20.1013 2MCR-NV-4191 NV 03/05/08 CLR N N N VT-08-050 M21F1.20.1180 2MCA-CA-H11 CA 01/28/08 CLR N N N VT-08-034 M2.Fl .30.0031 2MCA-KC-3332 KC 02/06/08. CLR N N N VT-08-01 2 M2.F1.30.0032 2MCA-KC-3078 KC 02/05/08 REC N N N VT-08-074 Base plate out of tolerance. W/R 948112 used to repair the base plate. Hanger acceptable for continued service no operability concerns.M2.F1.30.0033 2MCA-KC-3030 KC 02/06/08 CLR N N N VT-08-011 M 0 ------ K 058 LNN--M2.F1.30.0034 2MCA-KC-3325 KC 02/05/08 CLR N N N VT-08-008-M2.F1.30,0035 2MCA-KC-3150 KC 02/07/08 CLR N N N "VT-08-033 M2.F1.30.0036 2MCA-KC-3144 KC 02/05/08 CLR N N N VT-08-014 M2.F1.30.0037 2MCA-KC-3274 KC 02/06/08 CLR N N N VT-08-005 M2.F1.30.0248 2MCA-KC-3011 KC 02/06/08 CLR N N N VT-08-004 M2.Fl.30.0254 2MCA-KC-3020 KC 02/05/08 CLR N N N VT-08-007 Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 SDQA Cat 'C" McGuire 2 6/11/2008 1:11:05 PM Page 6 of 9 Inspection Results fe, McGuire Unit 2 EOC-18 Insp Insp Insp System Date Status Limited Summary No Component ID Ref RFR Comment M2.F M2.F M2.F M2.F M2.F M2.F M2.F M2.F M2.F M2.F M2.F M2.G M2.G 1.40.0005 2RCP-B-SUPPORT NC 03/13/08 CLR N N N VT-08-062 1.40.0073 2NDP-SUPPORT-2A ND 01/30/08 CLR N N N VT-08-024 1.40.0074 2NDHX-SUPPORT-2A ND 02/25/08 CL- N N N VT-08-025 1.40.0075 2NSP-SUPPORT-2A NS 01/30/08 CLR N N N VT-08-026 1.40.0080 2NSHX-SUPPORT-2B NS 01/31/08 CLR N N N VT-08-027 1.40.0092 2NSHX-SUPPORT-2A NS 01/31/08 CLR N N N VT-08-028 1.40.0104 2SWIF-SUPPORT-2B NV 03/21/08 CLR N N N VT-08-072 1.40.0105 2NIP-SUPPORT-2B NI 01/29/08 CLR N N N VT-08-029-1.40.0106 2KFHX-SUPPORT-2A KF 01/29/08 CLR N N N VT-08-030 1.40.0132 2CRDM-SUPPORT NC 03/31/08 CLR N N N VT-08-081 i1.1.0004 2RCP-2D NC 03/17/08 CLR N N N UT-08-013 i3.1.0001 2NC2FW22-7 NC 03/10/08 CLR N N N PT-08-004 NC 03/10/08 CLR N N N UT-08-003 i6.2.0001 2PZR-Manway NC 03/13/08 CLR N N N VT-08-064 M2.G M2.Q1.1.0001 2NC2FW2-NW6 NC 03/07/08 CLR N N N UT-08-001 Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM Page 7 of 9 Inspection Results tr- McGuire Unit 2 EOC-1 8 Insp System Date Insp Insp -ao Status Limited Ref Summary No Component ID M2.Q1.1.0002 2NC2FW61-NW4 M2.Q1.1.0003 2NC2FW53-NW1 RFR Comment NC 03/14/08 CLR N N N UT-08-009 NC 03/14/08 CLR N N- N UT-08-010 M2.Q1.1.0004 2NC2FW53-NW2 M2.Q1.1.0005 2NC2FW53-NW3 M2.Q1.1.0006 2NC2FW13-NW5 M2.R1.11.0143 2NV2F-84 NC 03/14/08 CLR N N N UT-08-011 NC 03/14/08 CLR N N N UT-08-012 N N N UT-08-002 NC 03/09/08 CLR NV 03/11/08 REC N N N RT-N/A Indication determined to be film artifact and found to be acceptable. M2.R1.11.0189 2NV2FW115-5 NV 03/14/08 REC 99.00% N N RT-N/A Indication determined to be film artifact and found to be acceptable. M2.R1.11.0275 2NV2FW215-48 M2.R1.11.0278 2RCHPSS-OUT-1 NV 03/11/08 CLR N N N UT-08-005 NV 03/17/08 CLR 95.60% N N UT-08-014 During 2EOC-18 this item was examined as an additional sample for Summary Number M2.R1.11.0279. Reference PIP M-08-01705. M2.R1.11.0279 2RCHP-IN NV 03/14/08 REP 78.00% N -Y RT-N/A This weld was found to be reportable during 2EOC-1 8, additional sample was performed on M2.R1.11.0278 (2RCHPSS-OUT-1) and found to be acceptable.(Reference PIP M-08-01705). Weld was repaired and reexamined on 4-13-08 and found to be acceptable. Weld Limited to 78.00% RFR to be submitted for limitation. Printed 6/11/2008 1:12:07 PM GJU8302 v.01/01/08 SDQA Cat "Ce McGuire2 6/11/2008 1:11:05 PM Page 8 of 9 Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PM Page 8 of 9 Summary No M2.R1.1 1.0463 M2.R1.11.1534 M2.R1.11.1536 M2.R1.11.1594 M2.R1.11.1598 M2,R1.13.0002 Component ID 2NS2F427 2NV2FW115-4 2NVP8-3 2NV2FW215-37 Insp System Date NS 03/17/08 Inspection Results fo- .McGuire Unit Insp Insp -.o Status Limited Ref RFR REC N N N EOC-18 Comment RT-N/A Indication determined to be concavity and found to be acceptable. NV 03/14/08 REC N N N RT-N/A Indication determined to be film artifact and found to be acceptable. NV 03/11/08 NV 03/11/08 CLR N N N RT-N/A Indication determined to be film artifact and found to be acceptable. CLR 97.70% N N UT-08-004 2NV2FW215-49 NV 03/11/08 CLR N N N UT-08-006 2RV2FW30-27 N N N UT-08-15 RV 03/20/08 CLR Printed 6/11/2008 1:12:07 PM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 2 6/11/2008 1:11:05 PIVI Page 9 of 9 4.1 Reportable Indications There was one reportable indication for the examinations associated with this report period.4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair/ replacement activities, and corrective measures. There was one corrective action for the examinations associated with this report period.PIP M-08-1705 was written to document reportable indications found during RT examination on 2RCHP-IN (Summary Number M2.R1.11.0279). Plan Addenda 2MNS-034 was written to schedule one additional sample examination using ASME Section XI, IWC-2430 requirements of the 1998 Edition of ASME Section XI with the 2000 Addenda. The additional sample was scheduled and performed during EOC-18 and found to be acceptable. The reportable indications found during the RT examination were repaired during EOC-1 8. No code surveillance inspections are required because indications were repaired and found acceptable on 4-13-08.4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke's Corporate Office in Charlotte, North Carolina.McGuire Unit 2 Outage 3/EOC-18 Section 4 Page 2 of 3 Revision 0 June 3, 2008 4.4 Limited Examinations Limitations (i.e., 90% or less of the required examination coverage obtained)identified for examinations associated with this report period are shown below.A relief request will be submitted to seek NRC acceptance of the limited coverage. This information will be on file at the Duke's Corporate Office in Charlotte, North Carolina.Item Number M2.R1.11.0279 Percent Coverage 78.00%McGuire Unit 2 Outage 3/EOC-18 Section 4 Page 3 of 3 Revision 0 June 3, 2008 5.0 Owner's Report for Repair / Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.No item was determined to have had work performed outside this report period.Listed below is the information to address these issues.Work Order Number Signoff Date/EQO-C PIP Number N/A N/A N/A The NIS-2 forms included in this section were completed for work performed during this report period. The individual work request documents and manufacturers' data reports are on file at McGuire Nuclear Station.5.1 Class 1 and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 and 2 items during this report period. All Class 1 and 2 PSI examination data listed below is on file in the McGuire Nuclear Station QA Vault.Work Order Identification Number ISI Class 558698 Replace snubber on upper lateral support (SG-D) B 572524 Valve 2ND-3 replace body bolting B 586253 Replace body to bonnet bolting on Valve 2NV483 B 590178 Replace disc in valve 2NS44 B 590831-01 Replace 10 bonnet studs and 20 nuts on valve B 2FW28 590831-18 Machined 1" inspection port in bonnet and install B plug on valve 2FW28 592071-02 Replace valve 2BB1 B 592071-04 Replace material on hanger 2MCA-BB-5028 B 592071-23 Replace bolting material on hanger 2MCA-BB-5021 B 592072-02 Replace valve 2BB3 B 1702030 Work on hanger 2MCA-NI-5047 welds B 1710916 Replace disc in valve 2BB287 B 1713164 Replace body to bonnet bolting on valve 2NI184 B 1718559 Replaced valves 2Ni 15 and 354 and seal welded A and replaced piping 1719700-06 Replace valve 2NC1 A 1719700-25 Replace load pin in hanger A 2MCR-NC-4034 1722213 Replaced valve 2NC2 A McGuire Unit 2 Outage 3/EOC-18 Section 5 Page 1 of 4 Revision 0 June 11, 2008 Work Order Identification Number ISI Class 1745170 Replaced snubber and bolting material in extension B piece on hanger 2MCA-CA-59 1745171 Replaced snubber on hanger 2MCA-CA-1 30 B 1745172 Replaced snubber on hanger 2MCA-CA-130 B 1745174 Replaced snubber on hanger 2MCA-ND-6380 B 1745175 Replaced snubber on hanger 2MCA-NV-7009 B 1745177 Replaced snubber on hanger 2MCA-SV-58 B 1745179 Replaced snubber on hanger 2MCA-CA-140 B 1745181 Replaced snubber on hanger 2MCA-ND-5508 B 1745182 Replaced snubber on hanger 2MCR-NI-4699 B 1745184 Replaced snubber on hanger 2MCA-SV-1 B 1745185 Replaced snubber on hanger 2MCR-NI-4026 B 1745187 Replaced snubber on hanger 2MCA-SM-152 B 1745189 Replaced snubber on hanger 2MCA-CA-89 B 1745190 Replaced snubber on hanger 2MCR-NI-4556 A 1745191 Replaced snubber and 3/8" bolt at bracket on B hanger 2MCR-NI-4043 1745192 Replaced snubber on hanger 2MCR-NI-4716 B 1745194 Replaced snubber on hanger 2MCA-NI-4722 B 1745195 Replaced snubber on hanger 2MCA-CA-56 B 1745197 Replaced snubber on hanger 2MCA-SM-104 B 1745201 Replaced snubber on hanger 2MCA-ND-5580 B 1745202 Replaced snubber on hanger 2MCA-ND-6181 B 1745204,. Replaced snubber on hanger 2MCA-SM-1 9 B 1745205 Replaced snubber on hanger 2MCA-SM-20 B 1745206 Replaced snubber on hanger 2MCA-SM-1 53 B 1745207 Replaced snubber on hanger 2MCR-NI-4661 A 1745208 Replaced snubber on hanger 2MCA-SM-74 B 1.745209 Replaced snubber on hanger 2MCA-SM-283 B 1745285 Replaced bolting material at inlet and outlet flange B at valve 2NS2 1747839 Replaced material on hanger 2MCA-BB-5489 B 1750367-01 Replaced bolting material in flange at valve 2NV220 B 1751042 Replaced control valves on snubber at upper lateral B support SG-A 1751150 Replaced disc and bonnet on valve 2NM6 B 1761865 Replaced item 9 and 10 on hanger 2MCR-NV-4218 B 1761865-01 Replace valve 2NV841 and associated piping A 1761865-13 Replaced item 2 on hanger 2MCR-NV-4781 B 1769371 Replaced valve 2NC3 A 1799893 Replaced pivot pin in hanger 2MCA-CA-87 B McGuire Unit 2 Outage 3/EOC-18 Section 5 Page 2 of 4* Revision 0 June 11, 2008 Work Order Identification Number ISl Class 1801521-01 Seal welded body to bonnet on valve 2NI349 A 1802555 Replaced snubber on hanger 2MCA-S-NV-535-01 -H B 1802706 Replaced load pin in hanger 2MCR-NI-4025 A 1802766-01 Repaired weld 2RCHP-IN B 1802942 Replace items 3, 4, and 5 on hanger 2MCR-NV- B 5055 1803324 Replace snubbers on hanger 2MCR-NV-4106 A 1803674 -Replace snubber and adapter plate on hanger A 2MCR-NC-4272 1804042 Replace snubber on hanger 2MCA-NV-5315 B 5.2 Class 3 Preservice Examinations The Class 3 NIS-2 forms are not required by code for reporting purposes. The Class 3 forms are listed here to assist in the ISI Plan review process.Work Order Identification Number ISl Class 583573-07 Weld build-up on top and bottom of casing C 2RNPU0004 1699256 Piping added to RN system per MD200353 C 1699326-01 Replaced studs and nuts in flange 2KC4-FI2 at C valve 2KC57A 1699327-01 Replace bolting material in flange at valve 2KC82 C 1730869-39 Install new hanger on 2MCA-RN-3404 C 1730869-40 Install new hanger 2MCA-RN-3405 C 1730869-41 Install new hanger 2MCA-RN-3406 C 1730869-42 Install new hanger 2MCA-RN-3407 C 1730869-43 Install new hanger 2MCA-RN-3408 C 1730869-44 Install new hanger 2MCA-RN-3409 C 1730869-45 Install new hanger 2MCA-RN-341 0 C 1730869-46 Install new hanger 2MCA-RN-3411 C 1730869-47 Install new hanger*2MCA-RN-3412 C 1730869-65 Added piping and valves 2RN1086 and 2RN1087 C 1734686 Replace bolting in filter trap at flange 2NVFLOO51 C 1745180 Replace snubber and mounting bolting material on C hanger 2MCA-NB-14 1745196 Replace snubber on hanger 2MCA-KC-3030 C 1758578 Replaced bolting material in bonnet on valve 2LD32 C McGuire Unit 2 Outage 3/EOC-18 Section 5 Page 3 of 4 Revision 0 June 11, 2008 Work Order Identification Number ISI Class 1763015-26 Installed new hanger on 2MCA-RN-3413 C 1763015-32 Added piping and valves 2RN408 and 2RN410 C 1763015-46 Installed new hanger on 2MCA-RN-3413 C 1763617-32 Replaced valve 2RN69 C 1763617-60 Added item 12 on hanger 2MCA-CA-5625 C 1764228-32 Cut out and replace valve 2CA86 C 1785753 Added piping and valves 2RN404 and 2RN409 C 1801758 Replaced snubber on hanger 2MCA-KC-3332 C 1801841 Replaced snubber on hanger 2MCA-RN-3019 C 1802868 Added piping on RN System C 1802998 Replaced valve 2RN285 C 1805056 Replaced snubber on hanger 2MCA-CA-128 C McGuire Unit 2 Outage 3/EOC-18 Section 5 Page 4 of 4 Revision 0 June 11, 2008 FORM NIS-2 OWNER'S REPO' OR REPAIR / REPLACEMENT ACTIVITY As Required By The P,..,sions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S.-Church Street, Charlotte, NC 28201-1006 la. Date March 18, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 032 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NC -Reactor Coolant 3a. Work Order #-558698 Repair Organization Job #3b. NSM or MM 4. (b) Class of System: B#: N/A 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair ! Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Seral No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No Upper lateral Duke Power 88765043/2 N/A N/A N/A 0 Replaced, I support S/G D _0 Replacement 0 Yes B 0 Repaired, 0 No Upper lateral Duke Power 88765043/9 N/A N/A N/A 0 Replaced, support S/G D E_ Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,"__ _0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement ,0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each 3heet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work-Replaced snubber.8. Tests Conducted:Hydrostatic LI Pneumatic [1 Nom. Operating Press. LI Other LI Exempt-Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports tobe attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed Expiration Date N/A Date FL Grass Jr.QA Tech SDecialist -'Ofwnerf6r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by I e inspected the components described in this Owner's Report during the period 0 to- -O, ;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection., r ý-- erome F Swan Commissions NC1524, N-I Inspector's ,"nature National Board, State, Province and Endorsements Date Page 2 of 2 FORM NIS-2 OWNER'S REPO' -OR REPAIR / REPLACEMENT ACTIVITY As Required By The Pi,..,sions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date September 13, 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: ND -Residual Heat Removal 3a. Work Order #: 572524 Repair Organization Job #3b. NSM or MM#: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2ND-3 Dresser TH-03997 1937 N/A 1987 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 03 Replaced,_ _ _ _0 Replacement 0 Yes D 0] Repaired, .0 No 0- Replaced, S"0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this iorm.7. Description of Work-Replaced body bolting 8. Tests Conducted:Hydrostatic 0 Pneumatic El Nom. Operating Press. 0l Other El ExemptlI Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF 9. Remarks A functional will be Derformed when the snare valve is Olaced into the system.Q (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist-vner orOwner's Designee, Title Expiration Date N/A Date ? /J2,o 'CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 9-7 ; :-oandtatetaebe hat otandbesot of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -rome F Swan Commissions NC1524, N-1 Inspector's nAnure National Board, State, Province and Endorsements Date a ',"7 Page 2 of 2 FORM NIS-2 OWNER'S REPO' --OR REPAIR / REPLACEMENT ACTIVITY As Required By The P. .-ions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 9, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 122 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/.LA Expiration Date: N/A 4. (a) Identification of System: NV- Chemical and Volume Control 3a. Work Order #: Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, El No 2-NV-VA-483 Dresser TE09055 414 N/A 1978 0 Replaced,[0 Replacement 0 Yes B El Repaired, El No El Replaced, 0_ Replacement El Yes C El Repaired, 0] No o Replaced,_ Replacement 0l Yes -D 0l Repaired, El No El Replaced, El Replacement 0 Yes E 0l Repaired, El No El Replaced,]0 Replacement 0l Yes F El Repaired, El No El Replaced,__ Replacement El Yes Page 1 of 2 Form NIS-2 (Back), NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced body to bonnet boltinq.8. Tests Conducted:Hydrostatic 0 Pneumatic EJ Nom. Operating Press. E1 Other 0 ExemptO Pressure psig Pressure psig Pressure psig 9. Remarks Functional performed per task 3.Test Temp. OF Test Temp. OF Test Temp. OF (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass JrQA Tech Specialist Owner oF Owners Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected tk components described in this Owner's Report during the period-/ 1- C)ýA' to Yf/0-/"--; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injry or property damage or a loss of any kind arising from or connected with this erome F Swan Commissions NC1 524, N-I SInspector atureNational Board, State, Province and Endorsements kDate C Page 2 of 2 FORM NIS-2 OWNER'S REPC FOR REPAIR / REPLACEMENT ACTIVITY As Required By The F-, dsions Of The ASME Code Section XA 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte. NC 28201-1006 la. Date April 09, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 032 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/AA Expiration Date: N/A 4. (a) Identification of System: NS -Containment Spray 3a. Work Order #: 590178 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 03 No 2-NS-VA-44 Kerotest S18-8 411 N/A 1973 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,"___0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Reolaced disc.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. l] Other El Exemptl Pressure _psig Pressure .psig Pressure .psig 9. Remarks Functional preformed per task 03.Test Temp. OF Test Temp. OF Test Temp. OF (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed % & FL Grass Jr,QA Tech Specialist -O-wner or Owner's Designee, Title Expiration Date N/A Date "/ __CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspe ted the.omponents described in this Owner's Report during the period_ -oLto -G?-&and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for.any personal injury r property damage or a loss of any kind arising from or connected with this Sinspection.,t-/-/ rome F Swan Commissions NC1524, N-I ,,-- inspector's-ature National Board, State, Province and Endorsements (Page 2 of 2 FORM NIS-2 OWNER'S REPOt -OR REPAIR / REPLACEMENT ACTIVITY As Required By The Pr.. ,-ions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 18, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 ' O-Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3a. Work Order #: 590831-01 Repair Organization Job #3b. NSM or MM #: N/A 4. (a) Identification of System: FW-4. (b) Class of System: B 5. (a) ApplicableConstruction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, E0 No 2FW-VA-28 Walworth C56162 127 N/A 1974 0 Replaced, 21 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,"_0 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Reolaced 10 bonnet studs and 20 nuts.8. Tests Conducted:Hydrostatic 0] Pneumatic LI Nom. Operating Press. I] Other El Exempti Pressure psig Pressure psig Pressure psig 9. Remarks functional performed per task 09.Test Temp. OF__Test Temp. OF__Test Temp. ____F (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass JrQA Tech Specialist Owner opOwner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-2-16,09 to-3.. _1-/- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.,ZJ.-k1--lJerome F Swan Commissions NC1524, N-I Inspector's Signia re National Board, State, Province and Endorsements Date 7-1 Page 2 of 2 FORM NIS-2 OWNER'S REPC :OR REPAIR / REPLACEMENT ACTIVITY As Required By The P,ý-isions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 8. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: FW- Refueling Water 3a. Work Order #: 590831 -18 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME I1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 01 No 2FW-VA-28 Walworth C56162 127 N/A 1974 0 Replaced,]0 Replacement [0 Yes B 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0l No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No o Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced, D0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each;heet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Machined 1" inspection port in bonnet and installed plug.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. l] Other El ExemptO Pressure psig Pressure psig Test Temp. 9°F Test Temp. °OF Pressure psig Test Temp. OF 9. Remarks functional performed on task 26 per procedure MP/0/A/7700/045.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed _ FL Grass Jr,QA Tech Specialist Expiration Date N/A Date le Owner '76wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected thecomponents described in this Owner's Report during the period"-/-'-- 0 8 to l7-P- OT.'; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this I~_,,,,,inspection". 'nsetn.erome F Swan Commissions NC1524, N-I Inspector's Sgrfat#e National Board, State, Province and Endorsements Date apoy C Page 2 of 2 FORM NIS-2 OWNER'S REP( 'FOR REPAIR / REPLACEMENT ACTIVITY As Required By The, ..-visions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hacaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 013 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/._A Expiration Date: N/A 4. (a) Identification of System: BB -Steam Generator Blowdown Recycle 3a. Work Order #: 592071-02 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2BB-VA-1 Borg Warner 29936 1045 N/A 1978 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 2BB-VA-1 Flowserve Corp E-496P-1-1 2223 N/A 1999 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, El Replacement 01 Yes D 0 Repaired, 0 No 0 Replaced,"_ []0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced material per MD201761.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. 21 Other El Exempto Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Functional test performed per task 02.(Applicable Manufacturers Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section X1.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed _-YO FL Grass Jr,QA Tech Specialist Date ___Owner o(Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT hae inspected the omponents described in this Owner's Report during the period 0to a and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal in' ry or property damage or a loss of any kind arising from or connected with this[Finspection. erome F Swan Commissions NC1524, N-I Inspector's Kgature National Board, State, Province and Endorsements Page 2 of 2 FORM NPV-I MANUFACTURERS" DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the Provisioas of the AiE Code Rules Flowserve Corp... Manufactured by 701 First Street, Williamsport, PA 17701 Order (Newse & Address a( Duke Energy Corporation, P.O. Box 1015, Charlotte, NC.2. Manufactured foe Ordec No E496P-I MN 49678 (Nine and Address)ZZ801-1015. 3.4.5.Duke Energy Corporation Loc ooflPlantMcGuire Nuclear Station, 13225 Hagers Ferry Rd., Huntersville, NC.28078-8985. Pump or Valve [denuification-Valve, Two (I), 2"-l5O0#-.GateValve. Serial Numbers: E496P-1-1 and E496P-l-2 (Brief description t service far which equipment was designed)()DaigN. 74450 R/C Peadby Flowserve Corp.(a) Drawuig No. Prepared by (b) National Boid No.INB# 2223, NB# 2224 Design Conditions 3600 too O O (Pressure) (Temperature) 2 The material, design, construction, and workmanship complies with ASME Code Section [il. Class Edition_ 971_ _ , Addenda Date (S) 1973 Case No. N/A 7.Mark Na aT Z -:-L Spec. No. Manufacturer Rom arkcs (a) Castings Disc: Pc#l. Pr4#2 4. ----- 1~qARI ..CF8M CMI.. -Ht#--L-795.5--

  • -----*-*****........

Forgings ____Body: SN 11, SN 12 SA182-F316 BW/IP Pump Div.R -3038 iC: A5 .Bonnet: PC# 1., PC# 2 SA182-F316 Mid-Southern HT# L49056 ____________ Ai %k (b)V (c)(d)5400 8. Hydrostatic tes rPs.CERTIFICATION OF DESIiGN Design information on file at Flowserve Corporation, Williamsport, PA.17701 Stress analysis report on file at 3 Design specifications certified by R. E. Mi 1l er amie as above Stress analysis report certified by (1) Signature nor required. List name only.N/A (1) Prof. Eng. State SC Reg. No.4 2 3 7 (1) Prof. Eng. State -Reg. No._We certify that the statements made in this report are correct.Date /o/27/9 19 -Signed Flowserve Corp 8 (Manufacturer) Certificate of Authorization No. N3.712 expires 4/15/01 CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State ofRR;wn~ x of P-,Ran-y, I- A and employed byCOmm~rt'.l Hninn Tne_ .'n of BORn fln. MA have inspected the equipment described in this Data Report on '/'// ")K1-, _ and state that to the best of my knowledge and belief, the Manufacturer has constructed this equi.pmenc in accordace with the applicable Subsections of ASME Code, Section IIL" By signing this cercificace, neither the Inspector nor his employer makes any wananty, expressed or implied, concern-ing the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. '_#1 ---) AV Date 9 L/ -1 'Cha Young e 4. 1) 1 n Is 1/ /2 0 <* LILI 'V e (LoflmmssLonts Proinc a N.)(14ationet 8aaed. Stat..s Province and No.)Printed in U.S.A. (7/71)This fonn (E37) is obtaInable from the ASMZ. 34S E. 47th St.. New York. N.Y. 10017 FORM NIS-2 OWNER'S REPOh. ,-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 3. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 3a. Work Order #: 592071 --4 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: BB -Steam Generator Blowdown Recycle 3b. NSM or MM #: N/A 4. (b)Class of System: B 5. (a) Applicab!e Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, El No 2MCA-BB-5028 Duke Power N/A N/A N/A N/A 0 Replaced,_l Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 10 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced material per MD201761 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptOl Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/AFL Grass JrQA Tech Specialist Owneri'r Owner's Designee, Title Expiration Date N/A Date _____CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT_ aIe ins ected components described in this Owner's Report during the period to i5 O"; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. /( Jerome F Swan Commissions NC1524, N-I Inspectors Sig ?Oture National Board, State, Province and Endorsements Da~te I/j;oQ 0 C Page 2 of 2 FORM NIS-2 OWNER'S REPOR', .JR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 1,2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: BB -Steam Generator Blowdown Recycle 3a. Work Order #: 592071 -2.Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5.. (a) Applicable Construction Code: ASME II1 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section X1 Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 01 No 2MCA-BB-5021 Duke Power N/A N/A N/A N/A 0 Replaced,[] Replacement El Yes B 0 Repaired, El No O Replaced, 0] Replacement El Yes C 0 Repaired, 0 No O Replaced, 0 Replacement 0 Yes D 0 Repaired, El No 0 Replaced, 0_ Replacement El Yes E E Repaired, El No 0 Replaced, O Replacement 0 Yes F 0 Repaired, 0 No El Replaced,__ Replacement 0l Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced boltinci material.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptlA Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed Expiration Date N/A Date ___,5ýo FL Grass Jr,QA Tech Specialist Owner or'Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3 -ZJ'- oF3 to /-' 2-_- O.' ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for.any personal injury or property damage or a loss of any kind arising from or connected with this inspection. !Iw,. erome F Swan Commissions NC1524, N-I Inspector's S"igature National Board, State, Province and Endorsements Date //- OR -(Page 2 of 2 FORM NIS-2 OWNER'S REPOR) .J3R REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Comwany 526 S. Church Street, Charlotte. NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Comoanv Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: BB -Steam Generator Blowdown Recycle 3a. Work Order #: Repair Organization Job #3b. NSM or MM#: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped ,_Installed (yes or no)A 0 Repaired, 01 No 2BB-VA-3 Borg Warner 9089 105 N/A 1976 0I Replaced,[0 Replacement 0 Yes B 0 Repaired, 0I No 2BB-VA-3 Flowserve Corp 53BDY 1554 N/A 2005 0 Replaced, 21 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced material per MD201761.8. Tests Conducted:Hydrostatic E Pneumatic EJ Nom. Operating Press. 2] Other 5 ExemptD Pressure _psig Test Temp. OF Pressure _psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Functional test performed per task 02.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A1 FL Grass JirX)A Tech Rnecialist Expiration Date N/A Date It' Signed FL Grass Jr OA Tech Specialist Owner oeOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCTh e inspected th components described in this Owner's Report during the period to .'i'//./'.to

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for inspection.

', Jerome F Swan Commissions NC1524, N-I Inspector's Sigature National Board, State, Province and Endorsements I Page 2 of 2 FORM NPV-1 N CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES" As Required by the Provisions of the ASME Code , Section III. Div. I Pg. 1 of 2 Manufactured by IMlnwci'rvp C-nrn- n.lamf C ~.A. Cf ID- -i- '(No'no and Adkm= o N Ca~ft. Haid-)2_ Manufactured for Duk eEneE Colp. PO Bx 1015 Charlotte. C221lt (Nwmw wWd Admu d Pwdusor Ow-3. Location of Installation McGuire Station 13225 Havers Ferry Rd. RWY 73 Huntersville. NC 28078-8985 7 4. Pump or Valve Valve (Nan .O Ad Nominal Inlet Size 2" Outlet Size 2" (Exi)(a) Model No.Series No.or Type (b) N Certificate Holder's Serial No.(c) Canadian Registration No.(d) Drawming No.(1) Nat'L Bd. No.(g) Year Built-(e) Class 7 a (1) 1500# 7 53BDY/ N/A 74450 REV. B 2 Z 1554 2005 /(2)(3)(4)(5)(6)(7)(8)(9)(10)5. 2"-1500#-GATE VALVE (Cre o¢ c ro tfor ht'h equpmwt ww csnigerd)34252 Design*Conditions 1200 psi 567 'F or Valve Pressure Class 1500 (1)G. Cold Working Pressure ' psi at 100OF.I. Pressure Retaining Pieces Mark No. Material Spec. No. Manufacturer Remarks (a) Castings ".L7795 -SA351-CFSM Flowserve Gate 85500 '- SA182-F316 Flowserve' Bonnet 85511 = SA182-F316 Larson Body (1) For manually operated valves only*Supplemental si in fom of lists. skeches or drawingsmay be used provided (1) size is 8-1/2"x1x,1, (2) iformation in items 1, 2 and 5 on this -Data Report is Included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at top of this form.2-FORM NPV-1 (Back)Pg. 2 of .2 Valve S/N 53BDY/through j'Mark No.Material Spec. No.Manufacturer Remarks (c) Bolting (d) Other Parts "_,_.....9. Hydrostatic test 5400 psi. Disk Differential test pressure 3960 psi.I We certify that thre statemients made in this ronforms of .the ASME Code for Nucle Po er Addenda Summer 1973.-K Code Case Signed FIoWserve Corp.CERTIFICATE OF COMPLIANCE report are correct and that this pump, or valve, to the rules of construt 1971 Plant Components. Section Ill, Div. 1., No. N/A , Date Edition by (N CSc thiatieo hoo Our ASME Certificate of Authorization No.* N-1562 to use the N (NI symbol expires 11-26-06 Uratel CERTIFICATION OF DESIGN Design information on file at Flowserve Corporation Raleigh, NC Stress analysis report (Class 1 only) on file at Design specifications certified by (1) RPE. Miller PE State SC Reg. No. 4237 Stress analysis certified by (1)PE State Reg. No.(1) Signature not required. List name only.CERTIFICATE OF SHOP INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT of Hartford Connecticut have Inspected the pump, or valve, described in this Data Report on 6.- J _ and state that to the best of my knowledge and belief, the N Certificate Holder has constructed this pump, or valve, in accordance with ASME Code, Section Ill By signing this.certificate neither the Inspector nor his employer makes any warranty, expressed or implied. conceming the equipment described in this s Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property dama ora loss of any kind arising from or connected with this Inspection. Dated J.?. Lo.L-Signed _K~1 ' M1. A,.A_ Commission Llrt/VA .K;t 03,-- -- I/ -- -' ( kapctl (NMn 8d.. SlaW, Prio. ard No.)[bfYJ (52-FORM NIS-2 OWNER'S REPOI-, .-OR REPAIR I REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 24, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order #: 1702030 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, 0 No 2MCA-NI-5047 Duke Power N/A N/A N/A N/A 0l Replaced,[0 Replacement El Yes B 0 Repaired, El No[] Replaced,[] Replacement El Yes C El Repaired, 0l No 0l Replaced,_ Replacement El Yes D El Repaired, El No El Replaced, 0E Replacement El Yes E El Repaired, El No El Replaced,_E Replacement El Yes F E Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Cut items 3 and 4 then welded together after valve work completed.

8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exempt[o Pressure _psig Test Temp. OF Pressure _psig Test Temp. OF Pressure _psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,QA Tech Specialist Date -2 : Owner or,6wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-3 c' to 2Z. 1--OSand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

a ,rome F Swan Commissions NC1524, N-I Inspectors Si nature National Board, State, Province and Endorsements Date Dý -x2oY2P Page 2 of 2 FORM NIS-2 OWNER'S REPOR, .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. NIA Expiration Date: N/A 4. (a) Identification of System: BB -Steam Generator Blowdown Recycle 3a. Work Order #: 3b. NSM or MM #: 1710916 Repair Organization Job #ME201572 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2-BB-VA-287 Kerotest 96EP0329 N/A N/A 1996 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,_0 Replacement 0 Yes C 0 Repaired, 0 No o Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced disc.8. Tests Conducted:Hydrottatic 0 Pneumatic [] Nom. Operating Press. R1 Other El Exempto Pressure psig Test Temp. OF Pressure _psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Functional test performed per task 5.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of A thorization No. N/A Signed \ FL Grass JrQA Tech Specialist Owner wner's Designee, Title Expiration Date N/A Date ___CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected t, components described in this Owner's Report during the period 3 _ -Lz:J_0o L/y-[q_ ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inWury or property damage or a loss of any kind arising from or connected with this inspection. Jerome F Swan Commissions NC1524, N-I Inspector's 61gnature National Board, State, Province and Endorsements Date_______ C Page 2 of 2 FORM NIS-2 OWNER'S REPOQ OR REPAtR t REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 9, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a., Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Injection 3a. Work Order # : 1713164 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, El No 2-NI-VA-1 84 Walworth C55814 119 N/A 1974 El Replaced,[0 Replacement [] Yes B E Repaired, El No O Replaced, 0_ Replacement El Yes C El Repaired, El No El Replaced, 0E Replacement El Yes D El Repaired, El No El Replaced, DE Replacement El Yes E El Repaired, El No 0l Replaced, 0E Replacement El Yes F El Repaired, El No El Replaced, 0E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced body to bonnet bolting.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. l] Other E ExemptD Pressure psig Test Temp. OF Pressure psig Test Temp. _ F Pressure psig Test Temp. OF 9. Remarks Functional performed per task 8.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed \ FL Grass Jr,QA Tech Specialist Date ____'Owner ýOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the, components described in this Owner's Report during the period 24~ to zc-/a -Q5; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be: liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. //e F Swan Commissions NC1524, N-I Inspector' i ature National Board, State, Province and Endorsements Date q-/0)- go(y:1 Page 2 of 2 FORM NIS-2 OWNER'S REPORI ,R REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street. Charlotte. NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 EShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Injection 3a. Work Order #: 1718559 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: A N/A 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, C3 No 2NI-VA-15 Kerotest RT2-9 18123 N/A 1977 01 Replaced, 0_ Replacement 0 Yes B [ Repaired, El No 2NI-VA-15 BW/P International 96EP0224 82 N/A 1996 0l Replaced, 120 Replacement 01 Yes C El Repaired, El No 2NI-VA-354 Kerotest NU3-1 12030 N/A 1976 0 Replaced, 0_ Replacement 0 Yes D El Repaired, El No 2NI-VA-354 BW/P International 96EP0223 81 N/A 1996 [] Replaced, 2] Replacement 0Z Yes E El Repaired, El No NI Piping Duke Power N/A 83 N/A 1982 El Replaced, E0 Replacement 0 Yes F El Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced valves, seal welded, and piping between welds N12FW89-5 and 6.8. Tests Conducted:Hydrostatic 0 Pneumatic El Nom. Operating Press. 0l Other El Exemptl Pressure 2485 psig Test Temp. Ambient OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks test performed per MP/0/A/7650/076 on task 29.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE. I certify that the statements made in the report are correct and this conforms to the requirements of the ASMECode, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 4 FL Grass JrQA Tech Specialist Date -o, Owner^Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspted th components described in this Owner's Report during the period 1L -/,7to -/- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -rome F Swan Commissions NC1524, N-1 Inspector's ,0650ture National Board, State, Province and Endorsements Date ./ -. O Page 2 of 2 03/29/08 SAT 13:58 FAX QA LAB U001 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES-As Required by the Provisions of the ASME Code, Section III. Division I Pg. 1 of.2 1. Manufactured and certified by PIMP DIV., ]U, ANG OEES .P.C2300o .Z=0 AVZ-VE .MJ 9C58 4teme WA of N C fiieat. Holder)2. Manufactured for DUE P CO. SITE 13225 B ?m 1w), HWY 73 HI3T ,ILLE, NC 28078-8995 (name ard addrese of Pwcha$qofl

3. Location of Installation D=E !OlR CO. MCG0U] SXT1 13225 NALG EM R). lINT 73 191=71[LLE NC 28078-6985 (name and addreaal 4. Modal No.. Series No., or Typeo C rawlngDP-D9958-(1)

_ ay. D CAN N/A S. ASME Code, Section III. Division 1; 1971 -WIN= 1971 1 N/A (edition) leddemle date) Icieael (Code Ce.. no.)6. Pump or valve ___' ____Nominal inlet size 1] Outlet size "_ _(In.l Iin.i 7. Material: Body 5A152 7316 Bonnet N/A Disk SA479 TM 316 Bolting W/A (al (b) 10 Id) (e)Cott. Nat'l Body Bonnet Disk Holder's Board Serial Seriol Serial Serial No. No. No. No. No.81 320470 51J "/ N .. 313803_51(27 96NP0224 82 320470 M N/A 313803 96 2583 319759B W~ MUU-4 W/A31 0Em Suppleemantal inform of Ills", sketches, or drawings may be u$od provided 11) size is 6 x 11. relInformation in Items 1 through 4 an this Data A=eort Is ectuvded on each sheet, (3) each sheet Is numbtnrd end the number of aheem Is recorded at the top of this form.112188)This form lE000?) mry be obtained from the Order Dept.. ASME, 22 Law Drive, Dox 2300, FaIrflield, NJ 07007-2300. 03/29/08 SAT 13:58 FAX QA LAB (ao02 FORM NPV-1 (Back -Pg. 2 TMi Certificatm Holder's Serial No. 9%610225 3600 1001011 8. Design conditions PSI0 psi 100 OF or valve pressure clues 1500i iprusauril

9. Cold working pressure 3600 psi at 1O0OF 10. Hydrostatic test 5400-5450 psi. Disk differential test pressure 3960-4010 psi 11.Remarks: MTUnTRM CDVR.: WA82 GR 7316 .MOIPLA7B AI'!AC BY WMR (= B3WDLS SK COVER SM$61D223 314449A SN 96EP224 314449A ON4 96M225 314449A SM CERTIFICATION OF DESIGN Design Specification certified by ]M E] P.E. State N.C. Reg. no. 4860 Design Report certified by LAV[D A. M P.E. State CA neg. no. M19547 CERTIFICATE OF COMPIJANCE We certify that the statemernts made in this report ate correct end that this pump or valve conforms to the rules for construction of the ASME Code, Section Ill. Division 1.N Certificate of Authorization No ' --1130 .xp- loM Date." ,me Signed' mE-O.I4L DI:.IN Certilftilte Holder) ; epresent"Yel CERTIFICATE OF I N SPECT1ON I. the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors and the State or Province of e 0nd employed NMML DO. CD.of WO0DM have inspected the pump, or valve, described in thIs Date Report on 9LL'//i_/4/

.end state that to the beat of my knowlaege end belief, the Certificate Holder has con-stnucted this pump, or valve, in accordance with the ASME Code. Section III. Division 1.EMlf UTUAL D1MMM E AS80~!CVZ= By signing this certificate, neither the Inspectot nor his employer makes any warranty, or Implied, concerning the cornponent described In this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for arty personal Injury or property dom.,ge or a loss of any kind arising from or cooncted with this inspection. atSig Commissions A '/ 1 C , 6L"---i rled [Nat'l. 5d. l.de nd state or prey. end no.](1) For manually operated valves only. Enclosure 4.13 NIS-2 Owner's Report SM/O/A/8140/001; Page I of I Work Request/WO Task #0171 d'559ý-c/Section A Section B Section C OLD Component Removed From System Or OLD Component .To Be Repaired NEW Replacement Component Component

  1. Component Being Manf. Manf. National ASME Code Year Manf. Manf. National ASME Code Year Replaced/Repaired Name Serial # Board # Stamp Built Name Serial # Board # Stamp Built YES/NO YES/NO EXAMPLE Replaced Kerotest 1234 3 1976 BWIP 5678 5 1998 Valve I -NV-98 EXAMPLE Repaired Kerotest 5678 4 1977 Valve I-NV-99 Ink-e QI 94!'oeC L Receiving Inspection Report Form NPP-311A Rev.: 4 Page 1 of 2 Purchase Order No MN10751 E NPP-315 StocklCat ID: 224685 ! ID: 19512 Station C MEDB ID.: 235100526N Part No.: 09J-003 OA Shop No.: 0669 Vendor [BW/IP INTERNATIONAL INC Manufacturer:

IKEROTEST MFG. CORP.Item No. Quantity UTC No. Heat No. Lot NoJBatch No. Serial No.1 I [ -Ii I 850762 NA NA 96EP0223

Description:

VALVE,CHECK,Y,1-1/2",09J-003,ASME CLASS 1500,SW,SS,KEROTEST MFG. CORP.,ASME CLASS 1 CK'd SAMPLE Duke/ Inspection, Examination, and Testing Procedures/Standards By Size Pass Fail Vendor Performed -Specify Used CD] PII- L--- 1 w CDomment LIZWZ W ] ED LIZ~F EZIEi l Comments Visual/Configuration/Workmanship Dimensional RJ Approx. El Tolerance ElectricalI Magnetic (0) Yes ( No Weight Pressure: Chem. Analysis: Physical Properties: Other F NPP-311 Rev.: 4 I S] I GQA Condition: E] Commercial Grade E] Over-Check iI Calibrated Test, Examination, and Inspection Equipment Used: Instrument Type Model Number Serial Number Calibration Due I. Description of Problem [ Problems Sent To:j I S V:[Originator: Phone #:1 1 FAX #:Z ] Date: Z Accepted By: F Date: (Level II Receiving Inspector) Final GA Approval: F I Date: Receiving Inspection Report Form NPP-31 1 A Rev.: 4 Page 1 of 2 Purchase Order No MN10751 ED NPP-315 Stock/Cat ID: 1 224685 ID: 19513 Station M MEDB ID.: 235100526N ] Part No.: 09J-003 QA Shop No.: 0669 Vendor [BW/IP INTERNATIONAL INC Manufacturer: IKEROTEST MFG. CORP.Item No. Quantity UTC No. Heat No. Lot NoJBatch No. Serial No.1IZ I1I [852259 NA NA 96EP0224

Description:

VALVE,CHECK,Y,1-1/2",09J-003,ASME CLASS 1500,SW,SSKEROTEST MFG. CORP.,ASME CLASS 1 CK'd SAMPLE Duke/ Inspection, Examination, and Testing Procedures/Standards By Size Pass Fail Vendor Performed -Specify Used FD F D] Vi vlsua,/Configurationlorkmanship NPP-311 Rev.: 4D RI Dimensional RJ Approx. [] Tolerance LI [IIZ---- ] I----- []0 Electrical --CD FLZ --[[D] RJ magnetic 0 Yes (i) No I------ [I----- -- --[] Weight r-I-----Z][---- I---] []E Pressure: I__LI -ElI ElI [ [] E0 Chem. Analysis: 0QACondition: [j I F] E LI Physical Properties: E__ Commercial Grade i _ [__ ] [- Other F_] []Over-Check Comments Calibrated Test, Examination, and Inspection Equipment Used: Instrument Type Model Number Serial Number Calibration Due I. Description of Problem El Problems Sent To: S V: Originator: Phone #:Il FAX #: ] Date: j Accepted By: [ Date: (Level II Receiving Inspector) Final OA Approval: Date: I FORM NIS-2 OWNER'S REPOF OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 212 03 OShared (specify Units 31 Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. -N/A Expiration Date: N/A 4. (a) Identification of System: NC -Reactor Coolant 3a. Work Order #: 1719700-06 Repair Organization Job #3b. NSM or MM 4. (b) Class of System: A#:1 N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2NC-VA-1 Crosby N56925-00-0006 30 N/A 1974 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 2NC-VA-1 Crosby N56925-00-0003 27 N/A 1974 0 Replaced,_[]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced valve.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. 0 Other El ExemptFl Pressure 2235 psig Tes Pressure _psig Tes Pressure _psig Tes 9. Remarks Functional test performed per task 4.t Temp. 558 OF t Temp. OF t Temp. -°F (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist Owner or'Owner's Designee, Title Expiration Date N/A Date 2_i, o CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3-6o -O to i- /-Z ,; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection.rome F Swan Commissions NC1524, N-I I/ Inspector's i ature National Board, State, Province and Endorsements Date iL i2 (Page 2 of 2 r--" C.-OS Y VALV-E GA Coll, Yi R E NTH1, H ., H-A S,. -FORM NV--I FOR SAFETY AN;D SAFETY R.LIEF VALVES Q.C.-, 4 4 Ai -As required by tte Provisior.s of the I..ME Code Rules DATA REPORT LTB-27 Safety and Safety Rehef Valves.1 1'~I&tj.rt,.cct:red By Crosbv Valve & Gace Company, 43 Kendrick St., Wrentham. Mass. 02093 6116 lIB-BP-86 Name and Address woJel No. N-56925 Order No. N-300560 Contract Date 2/12/73 Duke Power Company 2. .ar.ufactured For Charlotte, 'North Crolina Order No. A-33957 Name and Address ,q.owner Duke Power Cempany, 422 South Church St.. ,Charlotte, North Carolina 28201 Name and Address 4..Location of Plant McGuire Nuclear Station Unit #1. Cowans Ford. North Carolina 5. Valve Identification I-NC-3 Serial No. N56925-00-0003 Drawing No. DS-C-56925 Rev. 0 2.154 Type Safety Orifice Size i Pip Size ___ lIlet 6 -*outlet 6 Safety.Safety Rehef. Pilot. Power Actuated Inch Inch Inch In, h o. Set Pressure (PSIc). 24R5# 700 F Rated 3 r Overl)ressure 3 _iicowdown W'SIG, 124 420006i'1/hr. Stamped Capacity ilydrostatic Test (PSIG) Inlet LS79 Complete Valve 750 7. The material, design. construction and workmanship comply with ASME Code. Sectiot: IIl.Class

  • I Edition 1971 Addenda Date Winter 1972 Pressure Containing or Pressure Retaining Components
a. Castings Body Bonnet b. Bar Stock and Forgings Support Rods Nozzle Disc Insert To Spring Washers Bottom Adjusting Bolt Spindle Spindle Ball Serial No.Identification N90397-31-0001.

N90353 0014 Mi03909 iQ0,%N90V.,-31:-0029 N 0 N 0 .N90351 0042 N90354-34-0019 N90355-0019 Material Specification Including Type or Grade ASTM A-351-72 Gr. CF81,, ASME SA-351 Cr. CF8¶.(ASTN A-105-71 Gr. IISA-105 Gr. HI ASTH* A-105-71. Cr. II AS'rM A-19J-"i0 Cr. B6 AS11b Sh-193 Cr. !P6 __ASTI4 A-276-72 Typc -1440 ASNi"1 SA-276 Tvpt' 440 C I Serial No. or Identification WCX-2761-0015 Material Specification Includir. Typ or Grade AS.1. A-304 Cr. 51":-1i ,. 0:t pitts sJch as Pilot Components pisc l!older l90356-35-0016 Inconel 718 AST.M A-7i (r. 8/Bonn:iet Stud 87589 AS,. SA-193 K,:r. 37 ASTMI. A-194-71 Gc..2d Bonn.et Stud Nut 2371 ASrE SA-]94 (:r : We certify thet the statements made in this report are correct.D.rte I-.-19 7 Signed Crosby Valve & CaPe Co.Manufacturer g QA Manager Certificate of Authorization No. 331 expires ._gpvember'9 1974.DESIGN IFTOP2MATION ON FILE AT CROSBY VALVE & GAGE CO.VAN'Y.DESIGN REPORT NO. EC-158.CER'17FICATE OF SHOP INSPECTIOh. I. the undersigned. holding x, r-alid commission issued by the National Board of Boiler api.Pre6ssue Vesstl Inspectors ar.- the State or province of S S. and e.hioyed by Mutual Boiler & ;!ach!in-erv insurance Co."-.'-' Lhw. hasve inspected the equipment descriled in this Data Report on 19- and state that to the best of my kncwledge and belief, the m.anufacturer ha.s constructed this equipi ment in accordance with the ap.:icable Subsections of Section Ill.By signing this certificate. sne-atiher the Inspector nor h-s employer inakes any w:r"nt'. ex.*pressed or implied. concerningu

he equipment .descritbed in this Data Report.Fur'.h:er;::ore.

neithe: the lnspe.ctor nor his employer shall be liable in any mariner for any.personal injury o, prupefty.damage or a loss of any kind a-r-ising frcin or connected with thGis inslpecton.i.

  • Factory Hutual Croup of Insurance Co.Date __ _ "/j'_19 7 1/-L '- " -"-"-:""'

Comrmissions "(Inspector ,Natminal r ,). o.,. pmo:rcr o :,r .V 1 . qN,,.. ,----4 DUKE POWER COMPANY DESIGN ENGINEERING DEPARTMENT VENDOR QUALITY ASSURANCE CERTIFICATION Name Of Vendor Crosby V,lve & (.7 Item No.Address of Vendor Plant Wrnntham, N .09?0g3 Spec. No.-CS-1205.O9 Rev.Component(s) or Material Steel Snfety Valvp Z ate 12!1A/75* Shippinq ID No.Release No. 1JA/,-. , , Mill Power Order No. A-33957 Certification Included Yes Full X "Partial The following listed tests and inspections have been completed as required by specification: (If partial certification, list materials or components for which certification applies.)1) Tested in accordance with rr-ngl-h)y Prce.dure 2)Physical and. Chemical Analysis Design Report Stress Report Heat Treatment Radiographic Test Ultrasonic Test Magnetic Particle Penetrant Tests V x x x X X.Major Repair Records and Chart Repair NDT Hydro (Test Press.-PSIG )Cleanliness, Operating Test Performance Curve ASME Data Report Personnel Qualifications on Record-1LA Deviation Record None.The following QA Docurmentatio-, as recu;,-ed by the specification is attached to'the original copy of this For-cm: (if partial certification, include documenta-tion applicable only to this specific shipi.ert.) Valve Document.;tiorn Pack.-ie Form 930.1 (Cant ;nued,' Rev. 1 Form 930. I (Cont;nued! Rev'. I DUKE POWER COrIPANY DESIGN ENGINEERING DEPARTMENT VENDOR QUALITY ASSURANCE CERTIFICATION' The listed component(s) or material(s) conform to the requirements of Duke Power Company Specification t.jcS-1205.O9 Pev. i Iwith the approved deviations noted above. The 0A documentation has been completed and attached to this form. No later than componen t or material shipment, the comolete QA documentation packet is being :ranrsmicred to Duke Power Ccmjany S. K. Blackley, Jr., Chief Engineer, Mechanical & Nuclear Division C. J. Wylie., Chief Engineer, Electrical Division L. C. Dail, Chief Engineer, Civil &Environmental Division Design Engineering Departrment P. 0. Box 2178 Charlotte, N. C. 28242"-A copy of this coV-e 2 '.'!n~C:- Qual' t. ..surance Certificatvo;-. forn wi1 be included with shipping papers- and shipped with the component to Duke Power CoMpany, at the address des ignated ia the sDec, fication. This is to certify that the item of equ;pmer.t identified above fully meets the requirenents of the above listed specification-inc.luding all of the codes, standards, test requirements, and quality assurance reouirenients invoked therein.a TitlIe ate Z-Form 930.1 Rev. i FORM NIS-2 OWNER'S REPO[-, .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: 2. Plant Address: Duke Power Comoany 526 S. Church Street. Charlotte, NC 28201-1006 la. Date April 5. 2008 Sheet 1 of 1 McGuire Nuclear Station 12700 Haaers Ferry Road., Huntersville, NC 28078 2a. Unit: 01 E32 03 EJShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: -NC -Reactor Coolant 3a. Work Order #: 1719700-25 Repair Organization Job #3b. NSM or MM 4. (b) Class of System: A#: N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or noi A El Repaired, 0 No 2MCR-NC-4034 Duke Power N/A N/A N/A N/A 0 Replaced, I 1 [20 Replacement El Yes B El Repaired, El No 0] Replaced,__ Replacement 0l Yes C El Repaired, 0l No 0l Replaced, 0_ Replacement El Yes D 0l Repaired, El No El Replaced,__ Replacement 0l Yes E E Repaired, El No 0l Replaced, 0_ Replacement 0l Yes F E Repaired, El No 0l Replaced, 0_ Replacement [] Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced load pin.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptl-1 Pressure _psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A.Certificate of Authorization No. N/A Expiration Date N/A Signed -.. FL Grass JrQA Tech Specialist Date I-S-1'-'w_"Ownerpf Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 7- 1 -o6 to '- <-.OP; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj ry or property damage or a loss of any kind arising from or connected with this inspector./ erome F Swan Commissions NC1524, N-I Inspector' Snature ' National Board, State, Province and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REPOR. OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferr' Road. Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 3a. Work Order #: 1722213 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/.AA Expiration Date: N/A 4. (a) Identification of System: NC -Reactor Coolant 3b. NSM or MM #4. (b) Class of System: A N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2NC-VA-2 Crosby N56925-00-0007 523 N/A 1978 01 Replaced,[0 Replacement 01 Yes B 0 Repaired, 0 No 2NC-VA-2 Crosby N56925-00-0007 523 N/A 1978 0 Replaced, 1214 Replacement 20 Yes C 0 Repaired, 0 No 0 Replaced, O Replacement 0 Yes D 0 Repaired, 0 No O Replaced,[O Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced valve.8. Tests Conducted:Hydrostatic El Pneumatic [] Nom. Operating Press. 19 Other 0 Exempt[]Pressure 2235 psig Test Temp. 558 OF Pressure psig Test Temp. OF Pressure _ psig Test Temp. OF 9. Remarks Valve removed from system sent to vendor to be tested and place back in original position for service. The functional test was performed per task 4.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,QA Tech Specialist Date -17 ,9,8 Owner ef Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected theyomponents described in this Owners Report during the period I R to Y-/ Y- d2; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this ./J erome F Swan Commissions NC1524, N-I ns~pec~tor's-"Tg0ture -National Board, State, Province and Endorsements D ateq-q Page 2 of 2 VCROSBY (.CROSBY VALVE l GAGE W R ENNTH AM , M A SS CO M PANY FORM NV-1 FOR SAFETY AND SAFETY RELIEF VALVES As required by the provisions of the ASME Code Rules DATA REPORT Safety and Safety Relief Valves AQ.C..4-4C I. Manufactured By Crosby Valve & Gage Co., 43 Kendrick St., Wrentham, MA 02093 Name and Address Model NO. HB-8 6-Urder No 300580J Contract Date 3/25/76National Board No. w.23 2. Manufactured For Duke Power Co., Charlotte, No. Carolina Order No. A33957 Name and Address s.Owner Duke Power Co., 422 "South Church St., Charlotte, North Carolina 28201 Name and Address 4. Location of plant McGuire Nuclear Station Unit, Cowans Ford, North Carolina 5. Valve Identification SPARE -1 Serial N0.N+S 6 9 2 5.'S00000 7 Drawing No. DS-C-56925 Rev. C Type Safety Orifice Size I M pipe Size Inlet 6 Outlet 6 Safety.Safety Relief.Pilot. Power Actuated Inch Inch Inch Inch 6. Set Pressure (PSIG) 2485 700 F Rated Temperature Stamped Capacity 420006 lbs./hr. Sat. t 3 _Overpressure-Blowdown z of ' ..P.Hiydrostatic Test IPSIG) Inlet 4575 Complete Valve 750 psig 7. The material, design, construction and workmanship comply with ASME Code. Section Ill.Class 1 Edition 1971 Addenda Date Winter 1972 Pressure Containing or Pressure Retaining Components Serial No. M a. Castings Identification Incl Body N90397-33-0007 ASME SA3 Bonnet N90353-41-0113 ASME SAI Case No.aterial Specification uding Type or Grade 51 Gr. CF8H 05 b. Bir Stock and Forgings 1ellot1z K56383-40-0036 Nozzle Disc Insert Spring WashersK56380-45-0110 Adjusting Bolt Spindle K56381-49-0143 N90356-40-0040 N90399-35-0011 N90426-37-0026 N90350-LO-0226 X90350-40-0237 N90151-44-0145:.N9 0354-47-0141 Inconel Alloy 718 ASNE SA182 Gr. F316 Haynes Stellite Alloy No. 6B AS'W SA1_5_ ___ASTM A193-70 Cr. B6 ASIrE SA193 Gr. B6 ASTI A193-73 Cr. B6 ASE SA193 Qr, 36 IL1 V Serial NO. or Identification Material Specification Including Type or Grade c. Spring K56380-45-0110 NX2761-0023 AST1X A304-76 _51B60H-d. Bolting e. Other parts such as Pilot Components Bonnet Stud 87589 ASTM A193 dr. B7 Bonnet Nut 2371 ASTM A197 CL. 24 We certify that the statements made in this report are correct.Date 3 7 19 Signed Crosby Valve & Gage Co.Manufacturer ByII ýCertificate of Authorization no. 1 87R expires September

30. 1980 CERTIFICATE OF SHOP INSPECTION I. the undersigned.

holding a valid commission issued by the qa .oVnal Board of Boiler and Pressure Vessei Inspectors and .he State or Province of Mass. and emploved by Factory Mutual Systems*. inspected the equipment described in this Data Report on , ,and state that to the best of my knowledge and belief, the Manufacturer r/s constructed this equip-ment in accordance with the applicable Subsections of ASME Section Ill.By signing this certificate, neither the Inspector nor his employer makes any warranty. ex-pressed or implied. concerning zhe equipment described in this Data Report.Furthermore. neither the Inspector nor his employer shall be Ihahle in any manner for any personal injury or property damage or a loss of ainy kli i -sng frn or connected with this inspection. Date 2 /.10 (rnspeCtc ri '- N -1'lor.'.i 1 rd. Slatw. Pr' ,- .....*Arkwright-Boston M!anufacturers Mutual Insurance Company -Mutual Boiler & Machinery Division.1~~\~JV -.DUKE POWER COMPANY QUALITY ASSURANCE DEPARTMENT SUPPLIER QUALITY ASSURANCE CERTIFICATION Name of Supplier Crosby Valve & Gage Company Address of Supplier Plant 43 Kendrick Street Wrentham, Mass, 02093 Date March 14, 1978 Mill Power Order No. A-33957 Duke Item or Req. No.Item 1 Spec. No. MCS-1205 .09-I Rev. I Supplier ID Nos.N56925-00-0007, N56925-00-00081 N56925-00-0009 Description of Component(s) or Material(s) Steel Safety Valves X Attached Documentation covers all Components/Materials on Mill Power Order.Attached Documentation covers partial shipment of Components/Materials on Mill Power Order.The following listed tests, inspections and reports have been completed as required by the specification: X Physical & Chemical Analysis X Hydro' (Test Pressure -PSIG 2485)*Crosby No. EC-158 & EC-427 X* Design Report NLA Radiographic Test X X Penetrant Test_X Operating Test X Dimensional Check N___X Major Repair Records & Charts X Personnel Qualifications on Record Stress Report Ultrasonic Test Repair NDE Performance Curve Deviation Record #Heat Treatment X Magnetic Particle.X Cleanliness _ ASME Data Report 1) Tested in accordance with Crosby Procedure T-16063 Rev- n 2)3)This certifies that the listed Component(s) or Material(s) conform to the requirements of the above referenced Duke Power documents including all codes, standards, test requirements and Quality Assurance requirements invoked therein.Supplier RepresentatA Authorit Signature Title Q. A. Supervisor Date ,L/,/97, (See Instructions) Form 930.IA/ Rev. 3 FORM NIS-2 OWNER'S REPO, .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 16, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater 3a. Work Order #: 1745170 Repair Organization Job #3b. NSM or MM #4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed _ yes or no)A El Repaired, 0 No 2MCA-CA-59 Duke Power 18063 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 03 Repaired, 0 No 2MCA-CA-59 Duke Power 36863 N/A N/A N/A 01 Replaced, 0 Replacement 0 Yes C C Repaired, 0 No 01 Replaced,[0 Replacement C Yes D 0 Repaired, 0 No 0 Replaced,[O Replacement 0 Yes E 0 Repaired, C No O Replaced,]0 Replacement [ Yes F 0 Repaired, C No C Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber and bolting material on extension piece.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptOl Pressure _psig Test Temp. 0 F Pressure psig Test Temp. OF Pressure _psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ' ( FL Grass JrQA Tech Specialist Date .3 4- , Ownerof OwCner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period Al!" 5ýa to_], -t I -j and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. rome F Swan Commissions NC1524, N-I Inspector's S 51Kture National Board, State, Province and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REPOi -'OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville. NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/.A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater 3a. Work Order #: 1745171 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, 0 No 2MCA-CA-1 30 Duke Power 20494 N/A N/A N/A 0 Replaced,.... _ _ Replacement El Yes B El Repaired, 0 NO 2MCA-CA-130 Duke Power 36861 N/A N/A N/A El Replaced,[0 Replacement 0l Yes C El Repaired, El No O Replaced,[O Replacement 0l Yes D 0] Repaired, El No 0l Replaced, 0] Replacement 0l Yes E [] Repaired, El No[] Replaced, 0l Replacement El Yes F 0 Repaired, El No 0 Replaced,_E Replacement [] Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic [l Pneumatic LI Nom. Operating Press. El Other LI Exemptl-Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. _ OF Test Temp. -OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached), CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed Expiration Date N/A Date -0 /FL Grass Jr,QA Tech Specialist Owner 6r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 0c Y to-.. 1_-/ ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection .--rome F Swan Commissions NC1524, N-I Inspector's 8ig- 9ture National Board, State, Province and Endorsements Date :_Zoo C Page 2 of 2 FORM NIS-2 OWNER'S REPOR OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Companv 526 S. Church Street. Charlotte, NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 103 EZShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater 3a. Work Order #: 1745172 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No, Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0] Repaired, E1 No 2MCA-CA-130 Duke Power 21774 N/A N/A N/A 01 Replaced,[0 Replacement 01 Yes B 0 Repaired, 01 No 2MCA-CA-1 30 Duke Power 36862 N/A N/A N/A 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work_Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptl@Pressure psig Pressure psig Pressure psig Test Temp. _ OF Test Temp. OF Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed Expiration Date N/A Date =5 '- 1 _42_F! (r~ .lrOA Tech ~n~i~li~t.. .... Grs .. .... OA TechSpecalis" Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the gmponents described in this Owner's Report during the period a -I/_ Q& to -3__/ -06and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. I o.~me F Swan Commissions NC1524, N-I , Inspector's 81gfature National Board, State, Province and Endorsements Date-3 4I /OV l Page 2 of 2 FORM NIS-2 OWNER'S REPORF .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 []Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: ND -Residual Heat Removal 3a. Work Order # : 1745174 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built corrected, Removed, or ASME Code Stamped.Installed (yes or no)A El Repaired, 0 No 2MCA-ND-6380 Duke Power 21755 N/A N/A N/A 0 Replaced,..__0 Replacement El Yes B 0l Repaired, 01 No 2MCA-ND-6380 Duke Power 14908 N/A N/A N/A 0l Replaced,..__-'_ Replacement 0] Yes C El Repaired, El No 0l Replaced, El Replacement El Yes D El Repaired, El No El Replaced, El Replacement 0l Yes E E Repaired, El No El Replaced, 0l Replacement El Yes F E Repaired, El No El Replaced, 0E Replacement 0l Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work.Reolaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptOl Pressure .psig Pressure .psig Pressure .psig Test Temp. _ OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed \.-- FL Grass JrQA Tech Specialist Date Owner of'Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period__-_-_-___ 3 °-/o'- CA; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i inspection. me F Swan Commissions NC1524, N-I Inspector' i ature National Board, State, Province and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REPOR., -OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date March 24, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 E02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order#: 1745175 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair I Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name ot Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped...._ _Installed (yes or no)A 0 Repaired, 0 No 2MCA-NV-7009 Duke Power 20489 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-NV-7009 Duke Power 36859 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 01 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0O Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. LI Other LI Exempt@]Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -J -,4 FL Grass Jr.QA Tech Specialist Date .65-_s Owner,dr Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of -North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-t -,to-.3-state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, .Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. me F Swan Commissions NC1524, N-I Inspector's igna/ure National Board, State, Province and Endorsements Date ~ cc Page 2 of 2 FORM NIS-2 OWNER'S REPOi .:OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 1212 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SV -Main Steam Vent to Asmosphere 3a. Work Order #: 1745177 Repair Organization Job i 3b. NSM or MM #4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-SV-58 Duke Power 100 N/A N/A N/A 0 Replaced,]0 Replacement [l Yes B 0 Repaired, 0 No 2MCA-SV-58 Duke Power 36858 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes[0 Repaired, 0 No 0 Replaced, 0 Replacement E0 Yes F 0 Repaired, 0l No 0 Replaced, 0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exempt0 Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed "V FL Grass Jr,QA Tech Specialist Date ,Z4F.,', Owner 6r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 1,.- I q -0to -.- _L -z ,. and state that to the best of my knowledge and belief, the Owner has pedormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. I-rome F Swan Commissions NC1524, N-I Inspector's 9igr ture National Board, State, Province and Endorsements Date Page 2 of 2 FORM NIS-2 OWNER'S REPOR. OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XA 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 031 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 3a. Work Order # : 3b. NSM or MM #: 1745179 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 03 Repaired, 0 No 2MCA-CA-140 Duke Power 20372 N/A N/A N/A R1 Replaced, ,. ]0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-CA-1 40 Duke Power 19547 N/A N/A N/A 0 Replaced, 2-[] Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[] Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic E- Pneumatic El Nom. Operating Press. [] Other El ExemptlO Pressure --psig Pressure .psig Pressure .psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed e FL Grass Jr,QA Tech Specialist Owner orlOwner's Designee, Title Expiration Date N/A Date -oo7 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period X-1._ e to ,-[ I- ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ny personal inju or property damage or a loss of any kind arising from or connected with this spection. erome F Swan Commissions NC1524, N-I pector's Si- ature National Board, State, Province and Endorsements D te _ -[ -._(Page 2 of 2 FORM NIS-2 OWNER'S REPOR, OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 22 033 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: ND -Residual Heat Removal 3a. Work Order #: 1745181 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for. Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-ND-5508 Duke Power 14936 N/A N/A N/A 0 Replaced, I- C Replacement 03 Yes B 0 Repaired, 0 No 2MCA-ND-5508 Duke Power 36855 N/A N/A N/A 0 Replaced, 0 Replacement 0I Yes C 0 Repaired, 0] No 0I Replaced,[0 Replacement 01 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement C0 Yes E 0 Repaired, 03 No 0 Replaced, 0 Replacement 0 Yes F 01 Repaired, 0 No 0I Replaced,[0 Replacement 01 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic 0 Pneumatic El Nom. Operating Press. El Other E] ExemptOl Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp.. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code-Symbol Stamp N/A Certificate of Authorization No. N/A Signed Expiration Date N/A Date 4 4/4L5. 8 FL Grass JrQA Tech Soecialist Owne('or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period Z/Ly/- OK to-3 -"/JL- 12 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. A he Inseors Siature Jerome F Swan Commissions NC1524. N-I National Board, State, Province and Endorsements I Date .-1 , 7 D Page 2 of 2 FORM NIS-2 OWNER'S REPOR, .JR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 25, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 E02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order #: 3b. NSM or MM #: 1745182 Repair Organization Job #N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 02 No 2MCR-NI-4699 Duke Power 20732 N/A N/A N/A 0 Replaced,[0 Replacement_ 0 Yes B 0 Repaired, 0 No 2MCR-NI-4699 Duke Power 16569 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, O Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced, 1 0 Replacement 10 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic 0] Nom. Operating Press. El Other [0 Exempt--Pressure psig Test Temp. OF Pressure psig Test Temp. _ OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -& FL Grass Jr,QA Tech Specialist Date ,,_,' " ner, 'Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected thA components described in this Owner's Report during the period a_ I Y_ C toz, Z -; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj ur or property damage or a loss of any kind arising from or connected with this-,-).--'A. erome F Swan Commissions NC1524, N-I/ Inspec~tor'figfnature -National Board, State, Province and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REPOI-. :OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 9. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville,. NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SV- Main Steam Vent to Asmosphere 3a. Work Order #: 1745184 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped.... ..._In s t a lle d ( y e s o r n o )A 0 Repaired, 0 No 2MCA-SV-1 Duke Power 173 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B [0 Repaired, 2 No 2MCA-SV-1 Duke Power 36853 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work.Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptlZ Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. _ OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/AA Certificate of Authorization No. N/A Signed Expiration Date N/A Date ý 5 , FL Grass JrQA Tech Specialist 7 Owner oF Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT haye ins ected the components described in this Owner's Report during the period"?,-21 L toQ.- L-/c'D ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this) inspection. 9,PL F Swan Commissions NC1524, N-I Inspectors Sigrture National Board, State, Province and Endorsements Date ~Lj.O~(Page 2 of 2 FORM NIS-2 OWNER'S REPOR. .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OIShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/.A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order #: 1745185 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCR-NI-4026 Duke Power 20558 N/A N/A N/A R0 Replaced,[0 Replacement 0 Yes B 0 Repaired, EI No 2MCR-NI-4026 Duke Power 36852 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 01 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other [] Exemptl-1 Pressure .psig Pressure psig Pressure psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass JrQA Tech Specialist Ownerv)wner's Designee, Title Expiration Date N/A Date _ ,s CERTIFICATE OF INSERVICE INSPECTION I, the Undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the periodto. -.°: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. .-e..f ,.-A-Jerome F Swan Commissions NC1524, N-I SIwannspect or's tature National Board, State, Province and Endorsements Date Ay --_Page 2 of 2 FORM NIS-2 OWNER'S REPOt .:OR REPAIR / REPLACEMENT ACTIVITY.As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: -1 102 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SM -Main Steam 3a. Work Order #: 3b. NSM or MM #: 1745187 Repair Organization Job #N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME Il1 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped.._ _Installed (yes or no)A El Repaired, 0 No 2MCA-SM-1 52 Duke Power 22396 N/A N/A N/A 0 Replaced,__ Replacement 0l Yes B 0l Repaired, 0 No 2MCA-SM-152 Duke Power 15712 N/A N/A N/A El Replaced,[0 Replacement El Yes C El Repaired, 0l No 0 Replaced, 0O Replacement r- Yes D El Repaired, El No 0 Replaced,_E Replacement El Yes E 0 Repaired, El No 0l Replaced, El Replacement El Yes F El Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form N IS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. [1 Other LI ExemptlZ Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. _ OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist Owner Qf Owner's Designee, Title Expiration Date N/A Date 3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period R to." -I I -Ot ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.Jerome F Swan Commissions NC1524, N-I Inspector's Sign re National Board, State, Province and Endorsements Date.- / Z-00 C Page 2 of 2 FORM NIS-2 OWNER'S REPOi :OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 011 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company 3a. Work Order #: Address: 526 S. Church Street, Charlotte NC 28201-1006 1745189 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater 3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)-A 0l Repaired, 0 No 2MCA-CA-89 Duke Power 20977 N/A N/A N/A 0 Replaced,]0 Replacement 0l Yes B 0l Repaired, 01 No 2MCA-CA-89 Duke Power 36851 N/A N/A N/A El Replaced, 20 Replacement [I Yes C 0 Repaired, El No 0 Replaced, O Replacement El Yes D 0l Repaired, El No 0l Replaced, 0_ Replacement El Yes E El Repaired, C1 No O Replaced, El Replacement El Yes F El Repaired, El No El Replaced, 0E Replacement El Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each-sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exempt@-i Pressure psig Pressure .psig Pressure psig Test Temp. _ OF Test Temp. _ OF Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed Expiration Date N/A Date .-211-8 FL Grass Jr,QA Tech Specialist Ownewpor Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period'T- " to_._3-//- 00;:and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this f) inspection. I,,iJerome F Swan Commissions NC1 524. N-I/ -lnspectorsSigfiature National Board, State, Province and Endorsements 6 Date -I'U Page 2 of 2 FORM NIS-2 OWNER'S REPOR. OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 212 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 3a. Work Order #: 1745190 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3b. NSM or MM #: 4. (b) Class of System: A N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 01 No 2MCR-NI-4556 Duke Power 21122 N/A N/A N/A 0Z Replaced,[0 Replacement 0 Yes B 0 Repaired, 21 No 2MCR-NI-4556 Duke Power 36850 N/A N/A N/A 0 Replaced,[] Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0] Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work_Replaced snubber.8. Tests Conducted:Hydrostatic I] Pneumatic E Nom. Operating Press. LI Other LI Exemptl-Pressure psig Pressure _psig Pressure psig Test Temp. OF Test Temp. _ OF Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A* Signed FL Grass Jr,QA Tech Specialist Owner qOwner's Designee, Title Expiration Date N/A Date .-i7 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period iLZ-8 to Y; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this i inspection. rome F Swan Commissions NC1524, N-I SInspector's Prg~ature National Board, State, Province and Endorsements SDat~e,,3-- g .C Page 2 of 2 FORM NIS-2 OWNER'S REPOF,. .-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 25, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order #: 1745191 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A .l Repaired, RI No 2MCR-NI-4043 Duke Power 21752 N/A N/A N/A 0 Replaced,__ Replacement [] Yes B El Repaired, 01 No 2MCR-NI-4043 Duke Power 14765 N/A N/A N/A [E Replaced,[0 Replacement 0l Yes C 0l Repaired, El No El Replaced, o Replacement El Yes D 0l Repaired, El No El Replaced, El Replacement El Yes E El Repaired, El No El Replaced,__ Replacement El Yes F El Repaired, El No El Replaced,__ Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber and 3/8" bolt at bracket.8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. LI Other LI Exempt(]Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signe d '45t FL Grass Jr,QA Tech Specialist r Owner orOwner's Designee, Title Expiration Date N/A Date __CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period' to_7 -;.lo-oY and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. me F Swan Commissions NC1524, N-I lnspector's"5-gture National Board, State, Province and Endorsements Date -,-. Co 6 Page 2 of 2 FORM NIS-2 OWNER'S REPOk. (-OR REPAIR I REPLACEMENT ACTIVITY As Required By The Provisions Of. The ASME Code Section X1 1. Owner Address: 2. Plant Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 McGuire Nuclear Station 12700 Haoers Fern, Road. Huntersville. NC 28078 la. Date March 17, 2008 Sheet 1 of 1 2a. Unit: 01 02 033 -IOShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order #-1745192 Repair Organization Job #3b. NSM or MM 4. (b) Class of System: B#:- N/A 5. (a) Applicable Construction Code: ASME .1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 01 No 2MCR-NI-4716 Duke Power 20742 N/A N/A N/A 01 Replaced, o Replacement 0 Yes B 0 Repaired, 10 No 2MCR-NI-4716 Duke Power 36848 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. Li Other El Exempt0 Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be. attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed A FL Grass Jr,QA Tech Specialist Owner,6r Owner's Designee, Title Expiration Date N/A Date , CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period A q-N -Q& to -2, -j Ic- 0and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his 'mployer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this () inspection. ./i/6' erome F Swan Commissions NC1524, N-I PLInspector S nature National Board, State, Province and Endorsements Date-s -t 0 c 6 Page 2 of 2 FORM NIS-2 OWNER'S REPOi. (-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X(1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units .)3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. 1N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order#: 1745194 Repair Organization Job #3b. NSM or MM #4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Seral No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, [] No 2MCA-NI-4722 Duke Power 118 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-NI-4722 Duke Power 36847 N/A N/A -N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement [0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber, 8. Tests Conducted:Hydrostatic 0l Pneumatic El Nom. Operating Press. El Other El ExemptO Pressure .psig Pressure .psig Pressure psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed v.", FL Grass Jr,QA Tech Specialist ' Owvner or-Owner's Designee, Title Expiration Date N/A Date a CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and'the State or Province of North Carolina and employed by HSB CT have inspected th components described in this Owner's Report during the period OK to-.--//- 0 9; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -, Ierome F Swan Commissions NC1524, N-I 0/ ature National Board, State, Province and Endorsements Date-3j OQ Page 2 of 2 FORM NIS-2 OWNER'S REPO ,-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1, Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 10. 2008.Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 031 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a). Identification of System: CA -Auxiliary Feedwater 3a. Work Order #: 1745195 Repair Organization Job #3b. NSM or MM #4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, NI.A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component ..Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, El No 2MCA-CA-56 Duke Power 10734 N/A N/A N/A 0 Replaced,[O Replacement 0 Yes B 0 Repaired, 0] No 2MCA-CA-56 Duke Power 36846 N/A N/A N/A 0 Replaced, 0Z Replacement 0l Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0l No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic 0 Pneumatic [] Nom. Operating Press. 0 Other 11 ExemptlA Pressure .psig Pressure .psig Pressure .psig Test Temp. _ OF Test Temp. OF Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section X1.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed , FL Grass Jr,QA Tech Specialist Owner or'Owner's Designee, Title Expiration Date N/A Date _- _CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected thcomponents described in this Owner's Report during the period ,I9.Z-- to .3-/,/- OW; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section X1.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection..-y'-tt - F Swan Commissions NC1524, N-I Inspector'e'i ature National Board, State, Province and Endorsements Date- -//L cQo(!6 Page 2 of 2 FORM NIS-2 OWNER'S REPORI r-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl *1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1a. Date March 9, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 0I1 22 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SM -Main Steam 3a. Work Order#: 1745197 Repair Organization Job #3b. NSM or MM 4. (b) Class of System: B#:- N/A 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their Supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, RI No 2MCA-SM-104 Duke Power 197 N/A N/A N/A 0 Replaced,__ Replacement 0l Yes B C Repaired, 0 No 2MCA-SM-104 Duke Power 16035 N/A N/A N/A El Replaced,]0 Replacement El Yes C El Repaired, El No 0l Replaced,__ Replacement El Yes D El Repaired, [E No El Replaced, El Replacement El Yes E El Repaired, El No 0l Replaced, El Replacement El Yes F El Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this, form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptl-Pressure psig Test Temp. -OF Pressure psig Test Temp. -F Pressure _psig Test Temp. °F 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,QA Tech Specialist Date OWner orwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-+/-L-- to _ -i/0- 0 8; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. dn erome F Swan Commissions NC1524. N-I lnspector's Signoure National Board, State, Province and Endorsements Date Z/_. 9.__ Q Page 2 of 2 FORM NIS-2 OWNER'S REPORI i-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry'Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Comrpany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: ND -Residual Heat Removal 3a. Work Order #: 1745201 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-ND-5880 Duke Power 20667 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-ND-5880 Duke Power 36845 N/A N/A N/A 0 Replaced, , [0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 81/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Reolaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exempt[l Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the, statements made in the report are correct and this conforms to the requirements of the ASME Code, Section X1.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed F, i FL Grass Jr,QA Tech Specialist Owvner oeOwner's Designee, Title Expiration Date N/A Date -__ ___ __CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province, of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period.2.Ai/Z 2to-. -l 0; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinationsand corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this spection" J-erome F Swan Commissions M1524, N-I/Inspector's Sig /ture National Board, State, Province and Endorsements / Date --'_2>L, Page 2 of 2 FORM NIS-2 OWNER'S REPORI FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoanv 526 S. Church Street. Charlotte. NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hapers Ferry Road, Huntersviile, NC 28078 2a. Unit: 0' 1-02 03 []Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: ND -Residual Heat Removal 3a. Work Order #: 1745202 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, 0 No 2MCA-ND-6181 Duke Power 21917 N/A N/A N/A 0 Replaced,_l Replacement El Yes B0 Repaired, 01 No 2MCA-ND-6181 Duke Power 36844 N/A N/A N/A El Replaced, 01 Replacement 0l Yes C El Repaired, [] No El Replaced, El Replacement El Yes D El Repaired, 0l No El Replaced,__ Replacement El Yes E El Repaired, 0l No El Replaced, 0l Replacement El Yes F El Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. [] Other El Exempt[o Pressure _psig Test Temp. _ OF Pressure _psig Test Temp. OF Pressure _psig Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed " "- a FL Grass JrQA Tech Specialist Date ._,__-Owner g(Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period O 8to_-X ?o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 7 kpiIeerome F Swan Commissions NC1524, N-I Inspector's 'Si9ture National Board, State, Province and Endorsements Date Z Page 2 of 2 FORM NIS-2 OWNER'S REPO,.. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 9. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 0-2 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/.A Expiration Date: N/A 4. (a) Identification of System: SM -Main Steam 3a. Work Order #: 1745204 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998,. 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built corrected, Removed, or ASME Code Stamped Installed (yes or no)A 03 Repaired, 12 No 2MCA-SM-19. (A) Duke Power 15115 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-SM-19 (A) Duke Power 21768 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 2MCA-SM-19 (B) Duke Power 16137 N/A N/A N/A 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 01 No 2MCA-SM-19 (B) Duke Power 17366 N/A N/A N/A 0 Replaced, S] Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubbers 8. Tests Conducted:Hydrostatic [] Pneumatic [] Nom. Operating Press. El Other LI Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass JrQA Tech Specialist Date ___nWner or wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-Lq-V? to -06; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this inspection. erome F Swan Commissions NC1524, N-I Inspector's Sig a e National Board, State, Province and Endorsements Date-, Page 2 of 2 FORM NIS-2 OWNER'S REPOh, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date March 9, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1745205 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/_AA Expiration Date: N/A 4. (a) Identification of System: SM -Main Steam 3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair / Replacement Activity: 1998, 2000 Addenda -(1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built -Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-SM-20 Duke Power 15691 N/A N/A N/A 0I Replaced,[0 Replacement 0 Yes B 0 Repaired,, 0 No 2MCA-SM-20

'Duke Power 36876 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. [] Other LI Exemptl]Pressure psig Pressure psig Pressure .psig Test Temp. -OF Test Temp. OF Test Temp. -OF 9. Remarks 1 11(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed ',FL Grass Jr.QA Tech Specialist OWner or wner's Designee, Title Expiration Date N/A Date 1/ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 02-//- OOto-3.-/Z-a
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Jerome F Swan Commissions NC1524, N-I Inspector's Si ature National Board, State, Province and Endorsements Date 0 3008 6 Page 2 of 2 FORM NIS-2 OWNER'S REPOr,, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address
Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit:. 01 012 103 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1745206 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SM- Main Steam 3b. NSM or MM 4. (b) Class of System: B#:- N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity:

1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6.. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 01 No 2MCA-SM-153 Duke Power 21924 N/A N/A N/A 01 Replaced, 0 Replacement 0 Yes B 0 Repaired, 0I No 2MCA-SM-153 Duke Power 15711 N/A N/A N/A 0 Replaced,[] Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 10 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic [] Pneumatic El Nom. Operating Press. El Other LI Exempt-Pressure -psig Pressure .psig Pressure .psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed 4FL Grass JrQA Tech Soecialist Owvnier orowner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the omponents described in this Owner's Report during the period 2to -. c and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. rome F Swan Commissions NC1524, N-I Inspector's Sign 9re National Board, State, Province and Endorsements Date Page 2 of 2 FORM NIS-2 OWNER'S REPOr-. ..OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 25, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 E12 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Iniection 3a. Work Order #: 3b. NSM or MM #: 1745207 Repair Organization Job #N/A 4. (b) Class of System: A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: _ Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped ,,_ _Installed -Iyes or no)A 0l Repaired, 0 No 2MCR-NI-4661 Duke Power 18852 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0l No 2MCR-NI-4661 Duke Power 36875 N/A N/A N/A 0 Replaced, R0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work.Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other [] ExemptZ Pressure _psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section X1.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed_,-7, -a FL Grass Jr,QA Tech Specialist , t Owvner peOwner's Designee, Title Expiration Date N/A Date c2/2 4--W e CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period d-fij .- o to-3--Y- V3'; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj or property damage or a loss of any kind arising from or connected with this inspection. JY ome F Swan Commissions NC1524, N-I National Board, State, Province and Endorsements Datal29-3 -dZ (Page 2 of 2 FORM NIS-2 OWNER'S REPO. .FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 25. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SM- Main Steam 3a. Work Order #: 1745208 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, IZ No 2MCA-SM-74 Duke Power 21930 N/A N/A N/A 0 Replaced, O Replacement El Yes B 0 Repaired, EI No 2MCA-SM-74 Duke Power 22392 N/A N/A N/A El Replaced,__ Replacement 0 Yes C 0 Repaired, 0 No O Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0l Replaced,[0 Replacement 0 Yes E 0 Repaired, El No 0 Replaced, 0 Replacement 0 Yes F E Repaired, rl No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic E] Nom. Operating Press. [i Other 0] Exemptl]Pressure psig Test Temp. _ OF Pressure _psig Test Temp. OF Pressure psig Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed \ ,7_- FL Grass JrQA Tech Specialist Date "Owner boOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have ins ected the components described in this Owner's Report during the period-7 -Z-Od to -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this inspection. /-, A--r.-Jerome F Swan Commissions NC1524, N-I inspector's dgrature National Board, State, Province and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REPORi FrOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street. Charlotte. NC 28201-1006 la. Date March 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: .1 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: SM -Main Steam 3a. Work Order #: 1745209.Repair Organization Job #3b. NSM or MM 4. (b) Class of System: B#:- N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, -I No 2MCA-SM-283 Duke Power 17331 N/A N/A N/A 0 Replaced, 1 0 Replacement El Yes B E Repaired, 0I No 2MCA-SM-283 Duke Power 36631 N/A N/A N/A El Replaced,[0 Replacement El Yes C -El Repaired, [] No E Replaced, El Replacement El Yes D El Repaired, El No El Replaced,_E Replacement El Yes E El Repaired, El No El Replaced, 0E Replacement El Yes F E Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic [i Nom. Operating Press. [] Other LI ExemptL-Pressure psig Pressure psig Pressure psig Test Temp.Test Temp.Test Temp.OF-OF-OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section X1.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed y FL Grass JrQA Tech Specialist Owner orowner's Designee, Title Expiration Date N/A Date _- _CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCThae inspected the components described in this Owner's Report during the period_ýL- z2 to 6R; and state that to the best of my. knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements'of ASME.Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this wan Commissions NC1524, N-I-Inspector's Sign e -National Board, State, Province and Endorsements SDateec-'[ , l (Page 2 of 2 FORM NIS-2 OWNER'S REPOh I FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date March 28, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 12 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NS -Containment Spray 3a. Work Order #: 3b. NSM or MM #: 1745285 Repair Organization Job #N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped installed (yes or no)A 0l Repaired, 01 No NS Piping Duke Power N/A 69 N/A 1982 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No.0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, C Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E C Repaired, 0 No 0 Replaced,[0 Replacement C Yes F 0 Repaired, C No 0 Replaced,__ Replacement C Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced bolting material (studs and nuts) at the inlet and outlet flange at valve 2NS2.8. Tests Conducted:Hydrostatic fl Pneumatic 0 Nom. Operating Press. fZ Other LI Exempt*Pressure psig Test Temp. OF Pressure psig Test Temp. _ IF Pressure psig Test Temp. OF 9. Remarks Functional performed per task 5.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ---FL Grass Jr,QA Tech Specialist Date-Owner orewner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT hap inspected thgcomponents described in this Owner's Report during the period--21 to -5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. o ~ k~/j- t-,cJerome F Swan -Commissions NC1524. N-I Inspector's t ure National Board, State, Province and Endorsements Date !.- ccc. g Page 2 of 2 FORM NIS-2 OWNER'S REPOh. rOR REPAIR I REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 3, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: BB -Steam Generator Blowdown Recycle 3a. Work Order #: 1747839 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0l No 2MCA-BB-5489 Duke Power N/A N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,[0 Replacement El Yes C 0 Repaired, 0 No O Replaced,[0 Replacement 0 Yes D [0 Repaired, 0 No O Replaced,[o Replacement 0l Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement El Yes F 0 Repaired, El No O Replaced, 0] Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced material per MD20176.8. Tests Conducted:Hydrostatic E] Pneumatic El Nom. Operating Press. El Other El Exempti]Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/AFL Grass JrQA Tech Specialist Date 4/ UJ! Owner oVOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected th components described in this Owner's Report during the period d to Y_-L- 0A; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this kinspection rome F Swan Commissions NC1524, N-I inspector's 8iature National Board, State, Province and Endorsements Datecr at N Page 2 of 2 FORM NIS-2 OWNER'S REPOR I tOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date May 29, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 212 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 3a. Work Order #: 1750367-01 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports).6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 -Repaired, 0 No NV Piping Duke Power N/A 80 N/A 1982 0 Replaced, I- R Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 0O Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,_ _ _ _0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F [0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced boltingq material in flange at valve 2NV220.8. Tests Conducted:Hydrostatic fl Pneumatic LI Nom. Operating Press. LA Other El Exemptol Pressure psig Test Temp. _ OF Pressure _psig Test Temp. _ OF Pressure _psig Test Temp. _ OF 9. Remarks Visual functional performed per task 2 of this work order with no leaks detected.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass JrQA Tech Specialist Owner or 1 wner's Designee, Title Expiration Date N/A Date o_._CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT haye inspected the, omponents described in this Owner's Report during the periodý-/Y- o:>io 5-1 29:.- Aand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury o property damage or a loss of any kind arising from or connected with this inspection. u 0Swan Commissions NC1524, N-I Inspector's re National Board, State, Province and Endorsements Dates- 7 )9>6 Page 2 of 2 FORM NIS-2 OWNER'S REPOR i rOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hacqers Ferry Road, Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NC -Reactor Coolant 3a. Work Order #: 1751042 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME 111 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No Upper lateral Duke Power 4 N/A N/A N/A 0 Replaced, support S/G A R1 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, C [_ 0 Replacement 0 Yes C 0 Repaired, 0 No O Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0O Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No O Replaced, 1_11 Replacement 10 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced control valves in snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other E] Exemptl-Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -/ FL Grass Jr,QA Tech Specialist Date d,,-',.- -'Owner ofýOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3- 7 R to2-_/3- & D ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. t ý_Jrome F Swan Commissions NC1 524, N-I aNational Board, State, Province and Endorsements Date. X Page 2 of 2 FORM NIS-2 OWNER'S REPOi "OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 1a. Date March 26, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 012 03 I-IShared (specify Units )3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1751150 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NS -Nuclear Sampling 3b. NSM or MM 4. (b) Class of System: B#: N/A 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases-- (b) Applicable Edition of Section Xl Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2NM-VA-6 Kerotest VB34-19 21376 N/A 1977 0 Replaced, I_ 1 0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes.C 0 Repaired, 0 No 0 Replaced,[0 Replacement 03 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced, 0 Replacement 01 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced disc and bonnet.8. Tests Conducted:Hydrostatic 0 Pneumatic LI Nom. Operating Press. I] Other 0I Exemptol Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks MNT Functional performed per task 8.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ____ FL Grass Jr,QA Tech Specialist Date 3 .2.-,, Ownerr Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the.components described in this Owner's Report during the period.---- to-.? -- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this inspection. rome F Swan Commissions NC1 524, N-I Inspector's S tf dure National Board, State, Province and Endorsements Date-Z -,,'Page 2 of 2 FORM NIS-2 OWNER'S REPOK. -*OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 3, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 3b. NSM or MM #: 1761865 Repair Organlzatlon Job #N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,. N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)'6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mig Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 03 Repaired, 0 No 2MCR-NV-4218 Duke Power N/A N/A N/A N/A 0 Replaced, BR_ [ Replacement 0 Yes B 0 Repaired, El No 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, El No 0] Replaced,[] Replacement El Yes D 0l Repaired, El No El Replaced,]0 Replacement 0l Yes E El Repaired, 0 No 0l Replaced,[O Replacement El Yes F E Repaired, El No 0 Replaced, 0_ Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced item numbers 9 and 10.8. Tests Conducted:Hydrostatic E Pneumatic [] Nom. Operating Press. [i Other EJ Exemptl-Pressure .psig Pressure .psig Pressure .psig Test Temp. _ OF, Test Temp. _ OF Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/_A Certificate of Authorization No. N/A Signed ý -&44.Expiration Date N/A Date q__FL Grass JrQA Tech Specialist Ownerc'r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT hve inspected the components described in this Owner's Report during the period 2= 0 to O ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this/ inspection. m rome F Swan Commissions NC1524, N-I Inspector's SWabre National Board, State, Province and Endorsements Date 5; cb, y (Page 2 of 2 FORM NIS-2 OWNER'S REPOR r:OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order#: 1761865-01 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: A N/A 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2NV841 Kerotest 95EP0240 N/A N/A 1995 0] Replaced, 1 0 Replacement 0 Yes B 0 Repaired, 0 No 2NV841 BW/IP International 97EP0308 N/A N/A 1997 0 Replaced, 121 Replacement 0 Yes C 0 Repaired, 0 No NV Piping Duke Power N/A 80 N/A 1982 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,-- D0 Replacement 10 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work NV2FW102-5 & 6.Replaced valve and r)iDina between welds NV2FW73-32 & 37 and 8. Tests Conducted:Hydrostatic El Pneumatic 0l Nom. Operating Press. I] Other El Exempto Pressure psig Test Temp. _ F Pressure _psig Test Temp. OF Pressure psig Test Temp. °F 9. Remarks functional performed per task 04 bv procedure MP/O/A/7650/076.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass JrQA Tech Specialist Ownier or,6wner's Designee, Title Expiration Date N/A Date A' ,X CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT ye inspected th-components described in this Owner's Report during the period/12-Q to LiY; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Jerome F Swan Commissions NC1524, N-I DInspector- 'gnature National Board, State, Province and Endorsements Date L /~ 0, '0S2 Page 2 of 2 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section III, Division 1 Pg. 1 of 2 BR/fIP ONQLL INC.1. Manufactured and certified by PUMP DIV., IDLS OPERATION 2300 EAST VERNON AVE, VERNN. CA 90058 (name and address of N Certificate Holderl 2. Manufactured for DUKE POWER CO. McGUIRE SITE 13225 HA]GMS FEWR. RD. BHR 73 HUrTERSVILLE, NC 28078-8985 (name and address of Purchaserl

3. Location of installation DUKE POWE CO. MCGUIRE SITE 13225 HAGERS FERRY RD. HW! 73 HUNTERSVILLE.

NC 28078-8985 (name and addressl 4. Model No., Series No., or Type Drawing DP-D-9911-(1) Rev. C CRN MIA 5. ASME Code, Section III, Division 1: 1971 WUITER 1971 1 N/A (editionl (addenda date) (class) (Code Case no.)6. Pump or valve VALVE Nominal inlet size 2 Outlet size 2 (in.) (in.)7. Material: Body SAJL82 GR F316 Bonnet N/A Disk SA479 TYPE 316 Bolting N/A (a) (b) (c) (d) (e)Cert. Nat'l Body Bonnet Disk Holder's, Board Serial Serial Serial Serial No. No. No. No. No.97EP0303 N/A 328282 SN ARN'2 N/A 328293 SN 5 97EP0304 N/A 328282 SN AHN7-6 N/A 328293 SN 6 97EP0305 N/A 328282 SN AiM7-10 N/A 328293 SN 11 97EP0306 N/A 328282 SN AHM7-19 N/A 328293 SN 1I 97EP0307 N/A 328282 SN AEM8-2 N/A293 SN 17 97EP0308 N/A 328282 SN AHKB-3 NA 32R2_91 S_ IQ.Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8 Y x 11, 121 information in items I through 4* on this Data Report is included on each sheet, (31 each sheet is numbered atid the number of sheets is recorded at the top of this form.(12/88)This form 1E00037) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300. FORM NPV-1 (Back -Pg. 2 of _2_ 97ZV0303 THRU Certificate Holder's Serial No. 97ZV0308 3600 100 1500#8. Design conditions psi 1F or valve pressure class (1)(pressure) (temperature)

9. Cold working pressure 3600 psi at 1000F 10. Hydrostatic test 5400-5450 psi. Disk differential test pressure 3960:4010 psi 11. Remarks- MATERIAL COVER: SA182 GR F316 NAMEPLATE ATTACHED BY WIRE CERT HOLDERS SN COVER 97EP0303 328290 SN 1 97EP0304 328290 SN 2 97EP0305 328290 SN 3 97EPO306 328290 SN 4 97EP0307 328290 SN 5 97EP0308 328290 SN 6 CERTIFICATION OF DESIGN Design Specification certified by ROBERT EUGENE MILLER P.E. State N.C. Reg. no. 4860 Design Report certified by DAVID A. URANGIA -P.E. State CA. Reg. no. M19547 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section III, Division 1.-N Certificate of Authorization No. N-1130 J E x -JNE 10, 1999 Date Name INC.(N Certificate Holderl (authorized representativel CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ___ _ __ ___ __ and employed by -GUT of MOium, MASS. have inspected the pump, or valve, described in this Data Report on SEP' 2 3 199 , and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, in accordance with the ASME Code, Section III, Division 1.*FACTORYI MUTUAL ENGINEERING ASSOCIATION By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

W _ýWigN/ /misosP , ~' ,~ /S6 (fCmoisozed inspector) (Nat'l. 8d'"incl. endorsements) and state or prov. and no.](1) For manually operated valves only.\ vWo FORM NIS-2 OWNER'S REPO. ,-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 6. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 1761865-13 Repair Organization Job #3b. NSM or MM#: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0] No 2MCR-NV-4781 Duke Power N/A N/A N/A N/A 0 Replaced, 21 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 01 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,_0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, .0 No 0 Replaced,... 0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced item number 2.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptlZ Pressure -psig Pressure .psig Pressure .psig Test Temp. OF Test Temp. _ OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed ea FL Grass Jr,QA Tech Specialist Owner oe'Owner's Designee, Title Expiration Date N/A Date .,_,_CERTIFICATE OF INSERVICE INSPECTION' I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected th components described in this Owner's Report during the period-3 -O3j-0to -'- 0 2; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. -- .rome F Swan Commissions NC1524, N-I Inspýector'sg/81ture National Board, State, Province and Endorsements Date 0cLz22.O (Page 2 of 2 FORM NIS-2 OWNER'S REPO. ,zOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NC -Reactor Coolant 3a. Work Order #: 3b. NSM or MM #: 1769371 Repair Organizatlon Job 0 N/A 4. (b) Class of System: A 5. (a) Applicable Construction Code: ASME 111:1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998. 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0-] Repaired, 0 No 2NC-VA-3 Crosby N56925-00-0002 26 N/A 1974 10 Replaced, I 1 0 Replacement 0 Yes B 0 Repaired, 0 No 2NC-VA-3 Crosby N56925-00-0001 25 N/A 1974 C Replaced,[0 Replacement 0 Yes C 0 Repaired, [0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, C No O Replaced, 0 Replacement 0 Yes F 0 Repaired, C No 0 Replaced, 0] Replacement 03 Yes F 0 Repaired, C No 0 Replaced, 0_ Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced valve.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. 0 Other El ExemptD Pressure 2235 psig Test Temp. 558 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Functional test performed per task 4.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,QA Tech Specialist Date -/ /0/Ownerpf Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT hye inspected th omponents described in this Owner's Report during the period.t to -,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. & ,/ ,ý--erome F Swan Commissions NC1524, N-I Inspector's 8ig(ature National Board, State, Province and Endorsements Date Page 2 of 2 , S -'U-' f C CR 0 SUY VALVE 84 OA GE CO U PAAMY W R E UTH AL4 U 1 A S S FORM NV-I FOR SAFETY AND SAFETY RELIEF VALVES As required by the Provisions of the ASMI Code Ru:es DATA REPORT Safety and Safety Relief Valves Q.C.-44B NB-2-5 1. Manufactured By -- Crosby VaI ve & Gage Coapany, 43 Kendrick St.. Wrentham, Mass. 02093 6M6 IIB-BP-86 Name and Address Model No. N-5 6 9 2 5 O'rder No. N-300580 Contract Date 2/12/73 Duke Power Company 2. Manufactured For Charlotte, North Carolina' Order N.- A-33957 Name and Address S3-Owner Duke Power Company, 422. South Chtrch St.. Charlbtte. North Carolina 28201 Name 4nd Address 4. Location o( Plant McGuire Nuclear Station Unit #1, Cowans Ford, North Carolina 5. Valve Identification I-NC-I Serial No..N56925-00-0001 Drawingx No. DS-C-56925 Rev. 0 2.154 Type Safety Orifice Size M pipe size " Inlet 6 Outlet 6 Safety.Safety Relhef.Pilot.Power Actuated Inch Inch In,1. Inel'6. Set Pressure (PSIG) 248 5 " 70Q F Rated Temperitute -i 3 % overpressure 3 Blnwdown ,PSIGt 124 Stamped Capacity 420006#/hr f lydrostatic. Test (PSIGj Inlet 4575 Complete Valve 750 7. The material, design. construccion and workma-nship comply with AS'ME-Code. Scction Ill.Class I Edition 1971 Addenda Date Winter 1972 Pressure Containi,. or Pressure Retaining Components a:. Castings Body Bonnet b;. Bar Stock and Forgings Support Rods Nozzle Disc Insert Top Spring Washers Bo Ltom Adjusting Bolt Spindle Spindle Ball Serial No.Identification N90397-31-0003 N90353 0016 N90399-31-0003."N90426-33-00T0 NC90350-32-00356 O151" 3.~2 +"A 290354-34-0025 R90355-0025 Material Specification includig Type or Gr.,de ASTM A-351-72 Gr. CF8M-A ,U SA-!351_L ,__C_--AST1. A-105-71 Gr. II ASTH A-1.2-71 Cr. F ASM. SA-182 Q-r, F Hlavnes Stellite Cr. B6 AST'I4 A-I05-7I Gr. II.A$;:LlL__,5 _-10 Qi.C _.__I _____AS.E SA-193 Cr. 136:-..ASTM A-276-72 Type 440C ASMEI SA-276 T,,nc 440C.-..-...,-.,-r:r~' .~.- I-f A$i I I C-.C.I c. Spring Serial No. or Identification NIrX-2761-00 1fi Material Specification Including Type of Grade ASTM A-304 Gr. 516mir* d. Bolting e. Other Parts such as Pilot Components Disc Holder N90356-34-0014 Tnonpl.718 ..ASTM A-1U3-] (r. B/" Bonnet Stud 87589 AS.E SA-193 Qr, T7 ASTIM A-194-71 Gr. 2H1 Bonnet Stud Nut 2371. ASUE SA-'194 Cr. 2H We certify that the statements made in this report are correct.cage Co .By Date ..... 19..l_ Signed Crosby Valve &ma , Ic t Lu Cr QA Manager Certiticate ofat uthorization No. 331 expires November 9, 1974 DESIGN INTO1RMATION ON FILE AT CROSBY VALVE & GAGE COMPANY DESIGN REIPORT NO. EC-158 CERTIFICATE OF SHOP INSPECTION I. the undersigned, a valid commission issued by .he National Board of Boiler .nd Pressure Inspectors arn.d the State or Province cf.Ma,23- .ard employed by." Mutual Boiler & 1.. hi ,-"rns,:rarce Co.*, .Wi.altham. .-ass. have Inspected the cqtipnmeni dcscrt.ed in this Data Report on. 1 -and state tbat to the best of my knowledge and belief. the L.anufacturer has coinstructed this equip-ment in accord'-nce with the aplihcable Subsections of AS.ME Section ill.By signing this ce:tificate. reither the Inspector nor bis-employer makes any war.an.y. ez-pressed or iniplcd. concerntir. the equipment described in this Data Repott.ruttherniore. neither the Inspector no, his employer shall be hable many manner for any personal injury or. property damage or a loss of any kind arising from or connected with this inspection. -*Factory Mutual Group of Insuralice Co.Date 19 (lbaprctnr .-6.=-- Commissions ( tNaton-l Pord. Stzre. Provirce and No.i-w J. .DUKE POWER COMPANY DESIGN ENGINEERINIG ,EPARTMENT VENDOR' QUALITY ASSURANCE CERTIFICATION Name of Vendor Croshy Vlve fi.p ]pO2ny Item No.Address of Vendor Plant Wrenth-m, Mas._ 03, Spec. No-.CS.-205.O9 Rev. I Component(s) or Material Steel S.iferv Valve .Date 12/1I,7c;Shipping ID No.* Release No.L. -9:5 Mill Power Order No. A-33957 Certification Included Yes Full X Partial The following listed tests and inspections have been completed as required by specification: (If 'partial certification, list materials or components for which certification applies.)1) Tested in accordance lwitrh Ornphv PTrnL 4 i,- .T-11('6-n 2).3)Physical and. Chemical Analysis Design Report Stress. Report Heat Treatment Radiographic Test Ultrasonic Test Magnetic Particle Penetrant Tests X x x x X X Major Repair Records and Chart Repair NDT Hydro (Test Press.-PSIG )Cleanliness Operating Test Performance Curve ASME Data Report Personnel Qualifications on Record x x x_N/A x Deviation Record None.The following OA bocumentation as recuired by zhe specification is attached to'the original copy of this form: (If certification, include documenta-tion applicable only to this specific 5h,ip..ent.) Valve Document-.tioron F..ckr:fe Form ~3O.l (Continued) Rev. 1 Form 930.1!(Continued) Rev .1 IF DUKE POWER ti-iPANY DESIGN ENGINEERING DEPARTMENT VENDOR QUALITY ASSURANCE CERTIFICATION The listed component(s) or material(s) conform to the requirements of Duke Power Company Specification "c$-1205.09 Rev. I with the approved deviations noted above. The ;A documentation -as been completed and attached to this form. No later than component or material shipment, the corplete OlA documentation packet is being transmitted to Duke Power Company.S. K. Blackley, Jr., Chief Engineer, Mechanical & Nuclear Division-C. J. Wylie., Chief Engineer, Electrical Division L. C. Dall, Chief Engineer, Civil &Environmental Division Design Englineering Department P. 0. Box 2178 Charlotte, N. C. 28242-A copy of this completed Vendor Assurance Certific3tion worm will be included with shipping papers- and snipped with the component to Duke Power Cormpany, at the address des.ignated ir. the specification. This is to certifv that the item of eauipnert -dentifie! above fully meets the reQuiremrents of the above listed specification-inc.iuding all of the codes, standards, test requirements, and quality assurance reauirements invoked therein.*eVi-;z ie ori S ionature T i tie Da t e ___.Form 930.1 Rev. i FORM NIS-2 OWNER'S REPOR. ,-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 9. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hapers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 R12 03 OShared (specify Units 3. Work Performed By: Duke Power Company 3a. Work Order #: Address: 526 S. Church Street. Charlotte NC 28201-1006 1799893 Repair organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater 3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification -of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, 01 No 2MCA-CA-87 Duke Power N/A N/A N/A N/A 0 Replaced,[] Replacement 0 Yes B E Repaired, El No 0 Replaced, El Replacement El Yes C El Repaired, El No El Replaced, El Replacement El Yes D 0l Repaired, El No El Replaced, El Replacement El Yes E El Repaired, 0l No 0l Replaced, El Replacement El Yes F 0 Repaired, 0l No El Replaced, 0l Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced pivot pin.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. [] Other El Exempt---Pressure psig Pressure psig Pressure psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section X1.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed d .k ý FL Grass Jr,QA Tech Specialist T Owner otOwner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-' 0 to +/- Q -I -Q-,? and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this*nspection. .,e-z.-Je rome F Swan Commissions NC1524, N-I l-Inspector's Sidntture National Board, State, Province and EndorsementsO/-ff Page 2 of 2 FORM NIS-2 OWNER'S REPO; .FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date 03/22/2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Hu-ntersville, NC 28078 2a. Unit: 031 0X2 03 EShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. .(a) Identification of System: NI -Safety Iniection 3a. Work Order # : 01801521-01 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 11 No Valve 2NI-0349 Kerotest NU3-24 12035 N/A 1976 12Replaced, 1 0 Replacement I'KYes B El Repaired, El No 0l Replaced,_ Replacement El Yes C El Repaired, El No El Replaced, 0_ Replacement El Yes D El Repaired, El No El Replaced,_E Replacement El Yes E 0 Repaired, El No El Replaced,[E Replacement El Yes F El Repaired, El No E Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Made Bonnet to Body Seal Weld 8. Tests Conducted:Hydrostatic Li Pneumatic Li Nom. Operating Press.E Other Li ExemptilZ Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed' F.R. SorrowQA Tech Support Date 03/22, 2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the mponents described in this Owner's Report during the period 3-/- OA' to 3- ,,<B; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury roperty damage or a loss of any kind arising from or connected with this inspection. -ome F Swan Commissions NC1524, N-I Inspector's .ale National Board, State, Province and Endorsements Date.3-$3' Page 2 of 2 FORM NIS-2 OWNER'S REPO, zOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526S. Church Street. Charlotte. NC 28201-1006 la. Date March 18, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company 3a. Work Order #: Address: 526 S. Church Street, Charlotte NC 28201-1006 1802555 Repair OrganIzation Job *Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3b. NSM or MM #:.N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A E0 Repaired, E0 No 2MCA-S-NV-535-Duke Power 7655 N/A N/A N/A 0 Replaced, 01H _0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-S-NV-535-Duke Power 03615873-025 N/A N/A N/A 0 Replaced, 01H _] Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No-Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No o Replaced, 0 Replacement 1-0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptol Pressure psig Test Temp. _ OF Pressure psig Test Temp. _ OF Pressure psig Test Temp. -OF, 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,QA Tech Specialist Date .Yz, o, Owner o(Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned,. holding a valid commission issued by the National Board of Boiler and Pressure Vessel- Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period.a- J Z)3 to -1. -0$, and state that to the best of my knowledge and belief,, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By'signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. J F Swan Commissions, NC1524, N-I Inspectors 6igr ature National Board, State, Province and Endorsements Date t3 Y Page 2 of 2 FORM NIS-2 OWNER'S REPO. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 21, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/_A Expiration Date: N/A 4. (a) Identification of System: NI -Safety Injection 3a. Work Order #: 1802706 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: A 5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 03 Repaired, 0 No 2MCR-NI-4025 Duke Power 12101 N/A N/A N/A 0 Replaced, El Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced load pin.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptEO Pressure .psig Pressure .psig Pressure psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed wr n FL Grass Jr,QA Tech Specialist Owner or 6wner's Designee, Title Expiration Date N/A Date Jzi/-v8 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period Z4&-,V " O 'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this nspection. /inspectio. .4 -a. -- l.rome F Swan Commissions NC1524, N-I 7 Inspector's S-ignure National Board, State, Province and Endorsements Date-3.-91 2- ot0a 6 Page 2 of 2 FORM NIS-2 OWNER'S REPO. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date May 5, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 1802766-01 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: B N/A 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A NI- Repaired, 0l No NV Piping Duke Power N/A 80 N/A 1982 0- Replaced,]0 Replacement 21 Yes B El Repaired, 0l No O Replaced,__ Replacement E3 Yes C 0l Repaired, 0l No 0l Replaced,....1 0 Replacement 0l Yes D E0 Repaired, El No 0l Replaced,__ Replacement El Yes E El Repaired, 0l No 0l Replaced, I El0 Replacement El Yes F E Repaired, El No El Replaced, 0E Replacement El Yes Page t of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work ReDaired weld number 2RCHP-IN.8. Tests Conducted:Hydrostatic E Pneumatic El Nom. Operating Press. R1 Other El ExemptEO Pressure 2560 psig Pressure psig Test Temp. 94 OF Test Temp.OF Pressure psig Test Temp. OF 9. Remarks Functional performed on work order 1748696 -07 per procedure MP/O/A/7650/076.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist I 'Oývner qfOwner's Designee, Title Expiration Date N/A Date " __, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the periodto z; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this- Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this inspection --.-i erme F Swan Commissions NC1524, N-I Signa're -National Board, State, Province and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REPOt. .:OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 3. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 l12 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 3b. NSM or MM #: 1802942 Repair Organization Job #N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: _ Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, 21 No 2MCR-NV-5055 Duke Power N/A N/A N/A N/A 0l Replaced,[] Replacement El Yes B El Repaired, El No[] Replaced, 0_ Replacement El Yes C El Repaired, El No 0l Replaced,_ Replacement El Yes D El Repaired, C3 No 0l Replaced,_E Replacement El Yes E E Repaired, [E No El Replaced,[E Replacement El Yes F E Repaired, [E No El Replaced, 0E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced item numbers 3, 4, and 5.8. Tests Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other El Exempt@Pressure. psig Pressure psig Pressure .psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed 4,01 .FL Grass JrQA Tech Specialist Owner o(Owner's Designee, Title Expiration Date N/A Date __CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the. National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3- .f-,,f'to ,.Y- P/. O ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this /'1 4 Jerome F Swan Commissions NC1524, N-I"Inspector's National Board, State, Province and Endorsements Dater 6 Page 2 of 2 FORM NIS-2 OWNER'S REPG. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 24,. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 03 -Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 1803324 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCR-NV-4106 (A) Duke Power 5002 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 2MCR-NV-4106 (A) Duke Power 36739 N/A N/A N/A 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 2MCR-NV-4106 (B) Duke Power 10972 N/A N/A N/A 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 2MCR-NV-4106 (B) Duke Power 36738 N/A N/A N/A 0 Replaced,[] Replacement E] Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 01 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 10 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Wor kI Pgn n~sr'cdnri czhhinre 8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. 0l Other E- ExemptOl Pressure psig Pressure _psig Pressure .psig Test Temp. OF__Test Temp. ____F Test Temp. _OF_9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed , FL Grass Jr,QA Tech Specialist '0,ne'r--Owner's Designee, Title Expiration Date N/A Date *-5 ",/,,lofi CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have ins ected the components described in this Owner's Report during the period-:-Y 2- OT" toT 2-26-_A? and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspec~tion._- peti-n.4-i.--,,e rome F Swan Commissions NC1524, N-I Inspectors ture National Board, State, Province and Endorsements Date ____Page 2 of 2 FORM NIS-2 OWNER'S REPOt. iOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date April 1. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units _3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NC -Reactor Coolant 3a. Work Order #: 1803674 Repair Organization Job #3b. NSM or MM#: N/A 4. (b) Class of System: A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCR-NC-4272 Duke Power 3522 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 2MCR-NC-4272 Duke Power 35716 N/A N/A N/A 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 01 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber and adapter plate.8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. LI Other LI Exemptl-Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed 'N_4 & FL Grass Jr,QA Tech Specialist Owner ort-wner's Designee, Title Expiration Date N/A Date .-4Z/ ____CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period.3 -.I,-. O8 to 41- -" 0 ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. ome F Swan Commissions NC1524, N-I Inspector's ?g ature National Board, State, Province and Endorsements C I/Date I-/ /- IGO Page 2 of 2 FORM NIS-2 OWNER'S REPO, :OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 7. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 0-Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 1804042 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: B 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section X1 Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, IA- No 2MCA-NV-5315 Duke Power 945 N/A N/A N/A [] Replaced, 1 0 Replacement 0 Yes B 0 Repaired, IA No 2MCA-NV-5315 Duke Power 30700002/004 N/A N/A N/A 0 Replaced,_0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No O Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0l Repaired, 0 No 0 Replaced,[0 Replacement 0l Yes Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. E] Other LI Exemptl-'Pressure psig Pressure psig Pressure .psig Test Temp. _ OF Test Temp. OF Test Temp. °OF 9. Remarks (Applicable Manufacturers Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed or FL Grass Jr,QA Tech Specialist Oer or bwner's Designee, Title Expiration Date N/A Date 'iT 7 _CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected thV components described in this Owner's Report during the period Z5-- "8' to ')- C ; and state that to the best of my knowledge and belief, the -Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj or property damage or a loss of any kind arising from or connected with thislinspection. /Jerome F Swan Commissions NC1524. N-I nature National Board, State, Province and Endorsements K Page 2 of 2 FORM NIS-2 OWNER'S REPOi.. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date 03/27/2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferrn Road. Huntersville. NC 28078 2a. Unit: 01 rK12 03 ElShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN Nuclear Service Water 3a. Work Order # : 00583573-07 Repair Organization Job #3b. NSM or MM #: N/A 4;-. (b) Class of System: C 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A .XlRepaired, 0 No 2RNPU0004 Bingham B-2-988 88 (2B)RNPU 1973 0 Replaced,]0 Replacement [EYes B 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work (2B)Weld Buildup on ID Of Tor and Bottom Casinci of 2RNPU0004 8. Tests Conducted:Hydrostatic Li Pneumatic LI Nom. Operating Press. El Other Ei-Exempt-l Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A F.R. Sorrow,QA Tech Support Owner or Owner's Designee, Title Expiration Date N/A Date 03/27, 2008 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 4`7- to-3 lyl- ID ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this jinspection. rome F Swan Commissions NC1524, N-I nspector'sSQiature National Board, State, Province and Endorsements Date~r____ (Page 2 of 2 FORM NIS-2 OWNER'S REPOi.. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date June 28,2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a, Unit: 01 02 03 OShared (specity Units -)3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1699256 Repair Organization Job #3b. NSM or MM #4. (b) Class of System: C MD200353 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0l No RN Piping Duke Power N/A 60 N/A 1982 0 Replaced,_0 Replacement 0l Yes B -0 Repaired, 0 No o3 Replaced,]0 Replacement 0 Yes C 01 Repaired, 0 No 0] Replaced, 0 Replacement 0 Yes D 0] Repaired, 01 No 01 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,* ]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Additional piping added per MD200353.8. Tests Conducted: Hydrostatic El Pneumatic El Nom. Operating Press. 0 Other 0l Exemptol Pressure 91 psig Test Temp. 65 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Test performed per MP/O/A/7650/076.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,QA Tech Specialist Date .--'!-p._.Owner 6 r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 2liI~i a to 'akQ7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for Sany personal inju ra property damage or a loss of any kind arising from or connected with this ome F Swan Commissions NC1 524, N-I Inspectors glNational Board, State, Province and Endorsements Dae//C" Page 2 of 2 FORM NIS-2 OWNER'S REPO, ,, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date 03/21/2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 1K2 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: KC -COMPONENT COOLING 3a. Work Order # : 01699326-01 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, D3 No PIPING Duke Energy N/A 78 2KC 1982 0] Replaced,__Replacement ElYes B El Repaired, 0l No O Replaced, 0_ Replacement El Yes C El Repaired, El No 0 Replaced, O Replacement El Yes D El Repaired, El No..Replaced, El Replacement El Yes E 0l Repaired, 0l No El Replaced,__ Replacement El Yes F El Repaired, El No El Replaced, 0_ Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work.57A Replaced Studs and Nuts in flancie joint 2KC4-FL2 at valve 2KC-8. Tests Conducted:Hydrostatic Li Pneumatic LI Nom. Operating Press. LI Other l-ExemptliI Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed F.R. Sorrow,QA Tech Support Owner or Owner's Designee, Title Expiration Date N/A Date 03/21/2008 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National.Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT ha .e inspected thp,.components described in this Owner's Report during the period_3- 0 to. .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's.Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury o0 property damage or a loss of any kind arising from or connected with this nspection. erome F Swan Commissions NC1524, N-I.nspector's Sigrf tre National Board, State, Province and Endorsements Date-3_- A1-;_Page 2 of 2 FORM NIS-2 OWNER'S REPO, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street. Charlotte. NC 28201-1006 la. Date March 24, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haciers Ferry Road. Huntersville, NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: KC -Component Cooling 3a. WorkOrder#: 1699327 / 01 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No KC Piping Duke Power N/A 78 N/A 1982 0 Replaced, 1_ Replacement [] Yes B 0 Repaired, 0 No 03 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 01 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0] Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0l Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced bolting material in flange at valve 2KC82.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. l] Other El ExemptE Pressure psig Test Temp. OF Pressure _psig Test Temp. OF Pressure _psig Test Temp. OF 9. Remarks Visual functional performed per task 11 of work order.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed a FL Grass JrQA Tech Specialist wbrner or0 wner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have ins ected the components described in this Owner's Report during the period_ f-I -0 (Y to Q&,- I-o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i ,nspection .hFspecn. _,rome F Swan Commissions NC1524, N-IýInspectors Sigiit re National Board, State, Province and Endorsements Date -- C -" 0. -Page 2 of 2 FORM NIS-2 OWNER'S REPC. .FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date May 8, 2008 Sheet I of I 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road,. Huntersville, NC 28078 2a. Unit: 01 02 03 1Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/..A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order # : 1763015-32 Repair Organization Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASMVE 111 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, 0l No RN Piping Duke Power N/A 60 N/A 1982 0l Replaced,[0 Replacement 0 Yes B E Repaired, El No 2RN-VA-408 Crane D5479 N/A N/A 2006 0l Replaced, 20 Replacement 0] Yes C El Repaired, 0l No 2RN-VA-410 Crane D5892 N/A N/A 2006 0l Replaced, El Replacement 0I Yes D El Repaired, El No El Replaced, 0E Replacement El Yes E 0 Repaired, El No El Replaced,______________ ____ E Replacement El Yes F El Repaired, El No El Replaced,__0_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Added valves 2RN VA 408 and 410 with piping per MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. Z] Other El ExemptD Pressure 71 psig Test Temp. 52.4 OF Pressure psig Test Temp. _ OF Pressure psig Test Temp. _ OF 9. Remarks Functional performed per task 32 on procedure MP/O/A/7650/076.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed -,aQFL Grass JrQA Tech Specialist Owner or Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period ,-~-~-~- 2 o state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate .neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this/inspection. ,- -me F Swan Commissions NC1524, N-I Inspector's National Board, State, Province and Endorsements /Date /-J Page 2 of 2 r FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES,ýs Required by the Provisions of the ASME Code, Section III, Division 1*Corrected NPV-1 Pg. 1 of 2 1. Manufactured and certified CRANE Nuclear. Inc.. 860 Remington Boulevard. Bolingbrook, IL 60440 by (name and address of N Certficate Holder)2. Manufactured for Duke Energy Corporation. PO Box 1006, Charlotte, NC 28201-1015 (name and address of puroSser)3. Location of installation McGuire Nuclear Station. 13225 Haqers Ferry Rd. HWY 73. Huntersville, NC 28078-8985 (nams and address)4. Model No.. Series No.. or Type 5. ASME Code, Section 11, Division 1: 47-1/2UF-SPL 1998,-, (editon)g CC03984 Rev. C CRN N/A 2000 -- 3 N/A (addenda (class) [Code Case no.)date)6 Outlet size 6 (in.) 0in.)6. Pump or valve Gate Valve Nominal inlet size 7. Material: SA193 B8M .(a) valve Body SA351 CFBM .- Bonnet SA351 CF8M ^- Disk SA35 CF8M Bolting ' SA194 SM (b) pump Casting (a) (b)Cent. Nat'l Holder's .Board Serial No. No-Cover (C)Body/Casing Serial No.Bolting (d)Bonnet/Cover Serial No.(e)Disk Serial No.D5478 -" N/A 05408 -05409 D5422 D5479 -N/A 05405 D 05410 D5419 D50 N/A D5407 D- 5411 D5421.Supplemental information in the form of "Ists. sketches. or drawings may be used provided (1) size is B A x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this form.This form (E00037) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfied. NJ 07007.2300. FORM NPV-1 (Back) -- Pg. 2 of 2 Certificate Holder's Serial No.05478 through D5480 8 Design conditions 135 (pressure psi 150 "F or valve pressure class (temperature) (1)9. Cold working pressure 275 psi al 100'F 10. Hydrostatic test 425 psi. Disk differential test pressure 305 psi 11. Remarks: 'Corrected P.E. first name from James to Jesse.PO No. DP20357. PO Item 0040, Dukeltem No. 1MV-556 CNI SO No. 28451-04 CERTIFICATION OF DESIGN Design Specifications certified by *Jesse M. Hawkins P.E. State NC Reg. no. 20159 Design Report certified by NIA P.E. State NIA Reg. no. NIA CERTIFICATE OF COMPLIANCE We certify thaI the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section II1. Division 1.N Certificate of Authorization No..N-2899 Expires September

24. 2008 Date 08/09/06 Name CRANE Nuclear, Inc. Signed .Agk 9 (N ceriiricate Holder)Z Z JoehP r 'AEgnr CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT have inspected the pump. or valve, described In this Data Report on August 09, 2006 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, In accordance with [he ASME Code. Section I11. Division 1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore.

neither the inspector nor his employer shall be liable in any manner for any personal injury or properly damage or loss of any kind arising from or connected with this inspection. Date 08/09/06 Signed Commissions Todd ard IL 1903 IqNat'L Bd. (Ind. endorsements) and stale or pro,. and no.)(1) For manually operated valves only.% /FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES" As Required by the Provisions of the ASME Code, Section III, Division 1 Pg. 1 of 2 I. Manufactured and certified by CRANE Nuclear. Inc.. 660 Remington Boulevard. Botingbrook, IL 60440 (nalrf a J,0r0sS of N CCdef,.tlO H0ldelf 2. Manufactured for Duke Energy Corporation, PO Box 1006. Charlotte, NC 28201-1015

3. Location of installation

/McGuire Nuclear Station. 13225 Hagers Ferry Rd. HWY 73. Huntevsville. NC 28078-8985 Ina',e a'4 addess)4. Model No.. Series No.. or Type 47- 1,2UF-SPL Drawing CC04072 Rev. B CRN NIA 5. ASME Code. Section III, Division 1: V" 1998 (&on)/2000 taddend, d2le)3 (dZIS3)N/A (Cooe case no.).6... Pump or valve'Gate Valve Nominal inlet size 6 Outlet size ,_-6 (in.) tin.)7. .Materiat: (a) valve Body (b) pump Casting (a)Cert.Holder's Serial No./A26WC83 Bonnet VSA216 WC8 Cover (cI Body/Casing Serial No.Disk /SA351 CF8M Bolting (d)Bonnet/Cover Serial No."XA13 87 Bolting '2SA194 2H (b)Natl Board No.(e)Disk Serial No.w-',5892 D 5894 D5895 NIA D 5896 7' 505U08 --' 05916 N/A V, 05897 VD5909 ---__2:__:D5917 N/A D5898~II /1)5910 __ Z05______8 NIA %Zb589 05911 f IS 8 31'8W '82'Z-'V.Supplemenial itormation in the lormn aot sts. sketcres. or drawings may be used provided (1) size is 8 Y, x I I. (2) information in rteeis I though 4 on this Data Report is induded on each shceL (3) each sheet is numbered and rho number of sheets Is recorded at Irn top oW this loan.This form (E00037) may be obtained from the Order Dept ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.

  • 1 FORM NPV-1 (Back) --- Pg. 2 of 2 Certificate Holder's Serial No. /O5892 through 05895 8 Design conditions

-135 psi , 95 (pressure (temperature)

9. Cold working pressure / 285 psi at 100"F'F of valve pressure class (1)10. Hydrostatic test 450 psi. Disk differential test pressure V"315 psi 1 1.,Jemarks:

0-PO No. 00001637, PO Item 0007. Duke Item No. 1 MV-565 CNI SO No. 29401.01 ,,,6olting: Studs Hlt. # 2301 13/Nuts HI. # 387035 CERTIFICATION OF DESIGN Design Specifications certified by Jesse M. Hawkins P.E. State NC Reg. no. 20159 Design Report certified by NWA P.E. State N/A Reg. no. NIA CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code. Section III. Division 1.<Certifcate of Authorization No. N-2899 Expires September

24. 2008.,.7 Date 12/27/06 Name CRANE Nuclear, Inc. Signed (N Ceecaite HAere) ,, .'I CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford.

CT have inspected the pump. or valve, described in this Data Report on December 27. 2006 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump. or valve, in accordance with the ASME Code. Section Ill. Division 1.Bypogrinjg this certificate, neither the inspector nor his employer makes any warranty expressed or implied. concerning the ponent described in this Data Report.. Furthermore. neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection. Date 12/'27/0 Signed .k Commissions Robert Rains IL 932 (1) For manually operated valves only.-.' _. (-itji.Bi i~.erd 1erreiii3) and stato C Pr0". W4~ ;noj-,.- I. -*t.. " FORM NIS-2 OWNER'S REPOR, rOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date December 4. 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 DShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-39 Repair Organization Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Otlier Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 21 No 2MCA-RN-3404 Duke Power N/A N/A N/A N/A 0 Replaced, RI Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanaer oer MOD # MD200464.8. Tests Conducted:Hydrostatic EJ Pneumatic [] Nom. Operating Press. 0 Other LI Exemptg]Pressure psig Pressure psig Pressure .psig Test Temp. _ OF Test Temp. _ OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed 1 , FL Grass Jr,QA Tech Specialist Owner P**Owner's Designee, Title Expiration Date N/A Date -k CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspectedthe components described in this Owner's Report during the period"_027 to and state that to the best of my knowledge and belief, the Owner has performed exarninatiohis and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, Wither the Inspector nor his employer shall be liable in any manner for/ýny personal injury or operty damage or a loss of any kind arising from or connected with this/ spection. / F Swan Commissions NC1 524, N-I Inspector 's ~t N ational Board, State, P rovince and Endorsem ents Oate/2'/S--6 Page 2 of 2 FORM NIS-2 OWNER'S REPOR, rOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date December 5. 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 t02 03 EShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-40 Repair Organization Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 11 Repaired, 0 No 2MCA-RN-3405 Duke Power N/A N/A N/A N/A El Replaced,]0 Replacement El Yes B El Repaired, El No 0 Replaced,__ Replacement El Yes C El Repaired, El No O Replaced, El Replacement El Yes D 0l Repaired, El No El Replaced, 0_ Replacement El Yes E E Repaired, El No El Replaced, El Replacement El Yes F E Repaired, El No El Replaced, 0_ Replacement El Yes Page 1of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanaer oer MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptr-Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. _ OF Test Temp. _ IF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist"Uwher or,/wner's Designee, Title Expiration Date N/A Date /4,4.O _CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspecte the components described in this Owner's Report during the period 2Z727 to I-2.07"; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Jerome F Swan Commissions NC1.524, N-I Inspector's 'Siq~a re National Board, State, Province and Endorsements Date .-6 Page 2 of 2 FORM NIS-2 OWNER'S REPOi ,:OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Comoanv 526 S. Church Street, Charlotte, NC 28201-1006 la. Date December 5. 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/.A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-41 Repair Organization Job *3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped ,._Installed (yes or no)A 0 Repaired, 0 No 2MCA-RN-3406 Duke Power N/A N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes C [0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanger per MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other 0l Exemptrl Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass JrQA Tech Specialist Owner or pfjner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by C have inspected the components described in this Owner's Report during the period 11Z 7107 to/2,/S/ 7 ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this .__Jerome F Swan Commissions NC1524, N-I Jnespector'mgneuFre National Board, State, Province and Endorsements Date/= __6 Page 2 of 2 FORM NIS-2 OWNER'S REPOR. OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street. Charlotte. NC 28201-1-006 la. Date December 4, 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: D1 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3a. WorkOrder#: 1730869-42 Repair Organization Job #3b. NSM or MM #: MD200464 4. (a) Identification of System: RN -Nuclear Service Water 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A "1 Repaired, 0Z No 2MCA-RN-3407 Duke Power N/A N/A N/A N/A El Replaced,]0 Replacement El Yes B El Repaired, El No 11 Replaced,[O Replacement El Yes C El Repaired, El No O Replaced, 0_ Replacement -0 Yes D El Repaired, 0l No El Replaced, El Replacement El Yes E El Repaired, El No El Replaced, El Replacement El Yes F El Repaired, El No El Replaced, El Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanger per MOD # MD200464., 8. Tests Conducted:Hydrostatic El Pneumatic l Nom. Operating Press. 0l Other LI Exemptl-Pressure psig Pressure _psig Pressure psig Test Temp. _ OF Test Temp. OF Test Temp. __OF 9. Remarks (Applicable Manufacturers Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl..Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed -I --40 FL Grass JrQA Tech Specialist w~ner or ner's Designee, Title Expiration Date N/A Date ././. --CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period i4UTr 07to / ,l,,/o r-; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Frome F Swan Commissions NC1 524. N-I Inspectors Si ?at National Board, State, Province and Endorsements /Date Page 2 of 2 FORM NIS-2 OWNER'S REPOR , -OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1, Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date Jarnuary 2. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: [31 02 03 DShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-43 Repair Organizatlon Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0] Repaired, 0 No 2MCA-RN-3408 Duke Power N/A N/A N/A N/A El Replaced, 0I Replacement El Yes B El Repaired, El No 0l Replaced, 0_ Replacement El Yes C El Repaired, El No El Replaced,____0 Replacement El Yes D E Repaired, El No El Replaced, 0E Replacement El Yes E E Repaired, El No El Replaced, El Replacement El Yes F E Repaired, El No El Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanger per MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other LI ExemptlA Pressure .psig Pressure .psig Pressure .psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed S-e ý FL Grass JrQA Tech Specialist Date -4Z6 .zV Owner orowner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 7 to//-2 10e; and state that to the best of my knowledge and belief, the Owner has performed'dxardinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injur r property damage or a loss of any kind arising from or connected with this I/ inspection"Z. .,, rome F Swan Commissions NC1524, N-I I nspector's Si6jn' ye National Board, State, Province and Endorsements I Page 2 of 2 FORM NIS-2 OWNER'S REPOR'i r:OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoany 526 S. Church Street. Charlotte. NC 28201-1006 la. Date December 4. 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S..Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1730R69-44 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System; RN -Nuclear Service Water 3b. NSM or MM #K A rlV)r A r-A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No, Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0I No 2MCA-RN-3409 Duke Power N/A N/A N/A N/A 0 Replaced, 1 0 Replacement 0 Yes B 0 Repaired, 0 No O Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No O Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[] Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 10 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hancqer per MOD # MD200464.8. Tests Conducted:Hydrostatic 0l Pneumatic El Nom. Operating Press. El Other 0] Exemptol Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type.Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed .~ i' FL Grass Jr.QA Tech Specialist Date /24!'4?o2_ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspepeo the components described in this Owner's Report during the period/1/I :/97 to ,i/._ L; and state that to the best of my knowledge and belief, the Owner has performed eximinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for anypersonalinjY or property damage or a loss of any kind arising from or connected with this inspection. rome F Swan Commissions NC1 524. N-I Inspecs n ure National Board, State, Province and Endorsements Date Page 2 of 2 FORM NIS-2 OWNER'S REPOR. .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date December 4, 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 E12 03 OShared (specify Units 3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-45 Repair Organization Job #3b. NSM or MM 4. (b) Class of System: C#:- MD200464 5. (a) Applicable Construction Code: ASME II1 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-RN-341 0 Duke Power N/A N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, r_0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work_New installed hanaer oer MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic 0l Nom. Operating Press. El Other El ExemptZ Pressure psig Pressure psig Pressure psig Test Temp. -OF Test Temp. -OF Test Temp. -OF 9. Remarks (Applicable Manufacturers Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist ' d\ner or Wvner's Designee, Title Expiration Date N/A Date _,'- 2:2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HB CThave inspe ted the components described in this Owner's Report during the period 1Z" to/ toO,--2/ -; and state that to the best of my knowledge and belief, the Owner tas pdrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Sinspection. /inei.. --rome F Swan Commissions NC1524, N-I Inspector' SJ'n-zy National Board, State, Province and Endorsements Date-/ /7 Page 2 of 2 FORM NIS-2 OWNER'S REPOR OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date December 4, 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 DShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-46 Repair Organization Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped" Installed (yes or no)A 0 Repaired, 0 No 2MCA-RN-3411 Duke Power N/A N/A N/A N/A 0 Replaced, I] 0 Replacement 0 Yes B 0 Repaired, 01 No 0 Replaced,]0 Replacement 0 Yes C E0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement 03 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanger per MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El ExemptlA Pressure' psig Test Temp. OF Pressure _psig Test Temp. OF Pressure _psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed --, FL Grass Jr,QA Tech Specialist Date Owner geOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by CT have inspect ad the components described in this Owner's Report during the period.7, 0 to /Z 2Z A2Z and state that to the best of my knowledge and belief, the Owner h{s performed exarmlintions and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal i"jury or property damage or a loss of any kind arising from or connected with this inspection. r-,-ZrF c Jerome F Swan Commissions NC1524, N-I Inspec o' s 0 gnat e National Board, State, Province and Endorsements Date L__L._Page 2 of 2 FORM NIS-2 OWNER'S REPOh. r:OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date December 4, 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1730869-47 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. -(a) Identification of System: RN -Nuclear Service Water 3b. NSM or MM 4. (b) Class of System: C#: MD200464 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-RN-3412 Duke Power N/A N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D / 0 Repaired, 0 No[]Replaced,_ __ 0 Replacement 03 Yes E 0 Repaired, 01 No 0 Replaced,[] Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0] Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanger per MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exempt[O Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed A .ý, FL Grass JrQA Tech Specialist Date Owner V`Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspe ted the components described in this Owner's Report during the periodto 17 L.-S V and state that to the best of my knowledge and belief, the Owner has performed exatninations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Jerome F Swan Commissions NC1524, N-I Inspector's ignat e National Board, State, Province and Endorsements b~ate To k /Page 2 of 2 FORM NIS-2 OWNER'S REPOh, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 15, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haoers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 022 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1730869-65 Repair Organization Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A El Repaired, El No RN System Duke Power N/A 60 N/A 1982 0l Replaced, 0 Replacement 0 Yes B 0l Repaired, El No 2RN VA 1086 Crane D5360 N/A N/A 2006 0l Replaced,[0 Replacement 0] Yes C 0l Repaired, El No 2RN VA 1087 Crane D5462 N/A N/A 2006 0l Replaced,]0 Replacement 0I Yes D 0 Repaired, 0l No o Replaced,_E Replacement El Yes E 0 Repaired, 0l No 0l Replaced,__ Replacement El Yes F El Repaired, El No 0l Replaced,__ Replacement 0l Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced valve 2 RN-VA-1086 & 1087 and Piping per MD200464.8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom' Operating Press. I] Other El ExemptD Pressure 71 psig Test Temp. 52.4 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Functional performed per task 65 on procedure MP/0/A/7650/076.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A SignedcN.(/ZAý FL Grass Jr.QA Tech Specialist 'Owner o(Owner's Designee, Title Expiration Date N/A Date .__" CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period Z%- '7- Cto .-5S-09; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this irspection. rome F Swan Commissions NC1524, N-1 nspector's Signrture National Board, State, Province and Endorsements D ate ~ ~ c Page 2 of 2 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*Aýs Required by the Provisions of the ASME Code, Section III, Division I*Corrected NPV41 Pg. 1 of 2 1. Manufactured and certified by CRANE Nuclear, Inc., 860 Remington Boulevard, Bolingbrook, IL 60440 (name and o N Cerltifcate Holder)2. Manufactured for Duke Energy Corporation, PO Box 1006 Chalotte. NC 28201-1015 (name andiddress cfprotase,)

3. Location of installation McGuire Nuclear Station, 13225 Hagers Ferr Rd. HWY 73, Huntersville, NC 28078-8985 (name and address)4. Model No.. Seres No.: or Type 5. ASME Code, Section III, Division 1: 5341WE 1998 (edition)Drawing.CC03981 Rev. C CRN N/A 2000 3 (addenda (cass)date)6. Pump or valve Swing Check Valve Nominal inlet size 8 (In.)Outlet size N/A (Code case no.)8 (in-)SA193 S8M Bolting SA194 8M.7. Material: (a) valve Body SA3S1 CF8M (b) pump Casting Bonnet SA351 CF8M Cover Disk SA351 CF8M Bolting (a) (b) (c) (d) -Cert. Nat'l Body/Casing Bonnet/Cover Holder's Board Serial Serial Serial No. No. No. No.05359 N/A 5363 D5371 /, 05360 A3 05372 "" (e)Disk Serial No.D5375 /053762:4-Supplemental informadton In the form of lists, sketches, or drawings may be used provided (1) size Is:8 Y, x 1I. (2) information in items 1 through 4 on this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top 01 this form.This torm (E00037) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield.

NJ 07007-2300. 18197%7-9 1819780 FORM NPV-1 (Back) -- Pg. 2 of 2 8 Design conditions 7 135 (pressure Certificate Holder's Serial No.psi 150 *F or (temperature) 0 05359 through 05360 valve pressure class (1)9.10.Cold working pressure 275 psi at 100'F Hydrostatic test 425 7 psi. Disk differential test pressure 305 psi 11. Remarks: *Corrected P.E. first name from James to Jesse.PO No. DP20357. PO Item 0010. Duke Item No. IMV-559 CNI SO No. 28451-01 Hinge Pin Plugs: ASME SA182 F316, Heat # 56457 Cover Plua: ASME SA182 F316. Heat # 56457. Code ACT CERTIFICATION OF DESIGN Design Specifications certified by *Jesse M. Hawkins P.E. State NC Reg. no. 20159 Design Report certined by N/A P.E. State N/A Reg. no. N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code. Section III, Division 1.N Certificate of Authorization No.N-2899 Expires September

24. 2008 " Date 081/09/06 Name CRANE Nuclear, Inc. Signed (N Cerlr, cale Holder) , CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT have inspected the pump. or valve, described in this Data Report on August 0g, 2006 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section Itt, Division 1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described In this Data Report. Furthermore.

neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection. Date 08/09/06 Signed Commissions IL 1903 dl on ,Insepecto- ) i(Na. Eld. (nmd. endorsements) and slate or prov. and no.)( For mard (1) For manually operated valves only.181,97-19 18197-80; T i-~ -.,..1~' \ I. FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES, As Required by the Provisions of the ASME Code, Section III, Division 1 Pg. 1 of 2 1. Manufactured and certified CRANE Nuclear. Inc.. 860 Remington Boulevard. Bollngbrook, IL 60440 by (name and address of N Holder)2. Manufactured for Duke Energy Corporation. PO Box 1006, Charlotte. NC 28201-1015 (narme and address of urwdlaSer)

3. Location of installatldn McGuire Nuclear Station, 13225 Hagers Ferry Rd. HWY 73, Huntersville.

NC 28078-8985 (name and addre"s)4. Model No., Series No.. or Type 5. ASME Code, Section III, Division 1: IWAL221LGB3-3XG 1998 (ecition)Drawing CC03986 Rev. E CRN N/A 2000 (addenda date)3 N/A (daisl (Code Case no.)6. Pump or valve Butterfly Valve Nominal Inlet size 8 Outlet size lIn.)8 lInj 7. Material: (a) valve Body SA351 CF8M (b) pump Casting (a) (b)Cert. Narl Holder's Board Serial No. No.* End Cap /'Bonnet SA351 CF8M Cover (c)BodylCasing Serial No.Disk SA351 CF8M SA193 B8M Bolting CL 1 05462 /" 05463 NIA 05464 N/A D5465 Bolting (d) (e)"BonnetlCover Disk Serial Serial No. No.D5468 D5466 05469 .-.' D5467ýk~~~'~ us I2 I~T Ut4+ 1 0 4 L Supplemental information in the form of lists, sketches. or drawings may be used provided (1) size is 8 Yj x 11. (2) information in items I through 4 on this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this form.This form (E00037) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300-FORM NPV-1 (Back) -- Pg. 2 of 2 Certificate Holder's Serial No.05462 through 05463 8 Design conditions 135 psi 150 *F or valve pressure class (1)(pressure (temperature)

9. Cold working pressure 275 psi at 100F 10. Hydrostatic test 425 psi. Disk differential test pressure 305 psi 11. Remarks: PO No. DP20357, PO Item 0060, Duke Item No. IMV-560 CNI SO No. 28451.06 End Cap Bolts: HL # 150722 Valve supplied with Gear Operator CERTIFICATION OF DESIGN Design Specifications certified by Jesse M. Hawkins P.E. State NC Reg. no. 20159 Design Report certified by N/A P.E. State NIA Reg. no. N/A CERTIFICATE OF COMPLIANCE We that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code. Section III. Division 1.I N Certificate of Authorization No.Date August 30. 2006 N-2899 Expires September
24. 2008 Signed Name CRANE Nuclear, Inc.IN Cenftate Hol1cg)/ JOM .UMWL-.-5 S. GAEngR;;" CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT have inspected the pump, or valve, described in this Data Report on August 30. 2006 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code. Section III. Division 1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date 08130/06 Sign ed:iý -Commissions Fred.=v IL 1005 1IlNan. 8d. (ind. entS)and Uat, or proy. ad no.)(1) For manually operated valves only.042* I..-,' ` FORM NIS-2 OWNER'S REPOR. .-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date January 23, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 F02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NV -Chemical and Volume Control 3a. Work Order #: 1734686 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No NV System Duke Power N/A 80 N/A 1982 0 Replaced,[0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0l Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on'this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced bolting material in filter trap at flange 2NVFLOO51.

8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. 0 Other [] Exempt[Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Maint functional verified no leakage at system pressure.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the'report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist Owner $Owner's Designee, Title Expiration Date N/A Date /-A?_ __CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period/1- 27-70"'7o

-/ -: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations andcorrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or, a loss of any kind arising from or connected with this inspection. /Yo---- Seme F Swan Commissions NC1524, N-I SInspector's ,r~ure National Board, State, Province and Endorsements Date -C Page 2 of 2 FORM NIS-2 OWNER'S REPOI-. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date Aoril 6, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 03 DShared (specify Units _3. Work Performed By: Duke Power Comoany Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1745180 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: NB -Boron Recycle 3b. NSM or MM #4. (b) Class of System: C N/A 5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-NB-14 Duke Power 20718 N/A N/A N/A 0 Replaced, 1 0 Replacement 0 Yes B 0 Repaired, 03 No 2MCA-NB-14 Duke Power 36856 N/A N/A N/A 0 Replaced,__ Replacement 0 Yes 0 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0 Repaired, 0 No[] Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber and mountinci boltinci material.8. Tests Conducted:Hydrostatic El Pneumatic l] Nom. Operating Press. El Other El Exemptl-Pressure psig Pressure psig Pressure psig Test Temp.Test Temp.Test Temp.OF OF OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr.QA Tech Specialist"Owner ok 6 wner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-2cYto iL/-7-08 ; and state that to the best of my knowledge and belief, the Owner has performed-examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection., ome F Swan Commissions NC1524, N-I Inspectors nStipure National Board, State, Province and Endorsements Date 2- 0, (Page 2 of 2 FORM NIS-2 OWNER'S REPOi. -'OR REPAIR / REPLACEMENT ACTIVITY.As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street. Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 1745196 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/.A Expiration Date: N/A 4. (a) Identification of System: KC -Component Cooling 3b. NSM or MM #: N/A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI.Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-KC-3030 Duke Power 15122. N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-KC-3030 Duke Power 36877 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic E. Pneumatic El Nom. Operating Press. El Other 0 Exemptll Pressure psig Pressure .psig Pressure .psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist Owner ef Owner's Designee, Title Expiration Date N/A Date .-/v _,-: CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _North Carolina and employed by HSB CT have inspected th components described in this Owner's Report during the period-1:I',4/"9-Y to,3 -/F-0N; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury property damage or a loss of any kind arising from or connected with this/inspection.- --ý"-4erome F Swan Commissions NC1524, N-I Inspector's nure National Board, State, Province and Endorsements Date L.t 6 Page 2 of 2 FORM NIS-2 OWNER'S REPO,. .-OR REPAIR I REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X1 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 17, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hacers Ferry Road. Huntersville. NC 28078 2a. Unit: i-1 02 03 E]Shared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: LD -Diesel Generator Engine Lube Oil 4.3a. Work Order # : 1758578 Repair Organization Job #3b. NSM or MM #: (b) Class of System: C N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section X1 Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, El No 2LD32 Walworth C59073 576 N/A 1976 0 Replaced,__ Replacement 0 Yes B 0 Repaired, 0 No.Replaced, 0 Replacement El Yes C D Repaired, 0 No 0 Replaced, 0_ Replacement El Yes D C Repaired, 0 No 0 Replaced, 0 Replacement C Yes E 0 Repaired, C No El Replaced, C Replacement C Yes F 0 Repaired, 0 No 0 Replaced,_C Replacement 1C Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced bolting material in bonnet.8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. IA Other LI ExemptE Pressure psig Test Temp. __ F Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks External leakage performed per task 2 of this work order. No discrepancies found.(Applicable Manufacturers Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed N _ -FL Grass Jr,QA Tech Specialist Date ___, Owner grOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected th components described in this Owner's Report during the period-/vD- 0 rto --tr-Q; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. ome F Swan Commissions NC1524, N-I Inspector's gature National Board, State, Province and Endorsements Date Page 2 of 2 FORM NIS-2 OWNER'S REPOR. .-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date December 4, 2007 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN- Nuclear Service Water 3a. Work Order# : 1763015-26 Repair Organization Job #3b. NSM or MM #: MD200464 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-RN-3413 Duke Power N/A N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No E0 Replaced,]0 Replacement 0 Yes C 0l Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 01 Repaired, El No o Replaced, I-] Replacement 0 Yes E 0 Repaired, 0 No 0l Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0l Replaced,_0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hangqer per MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic LI Nom. Operating Press. El Other El Exemptr1 Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. _ OF Test Temp. _ OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed \a 1a FL Grass Jr,QA Tech Specialist Owner or Owner's Designee, Title Expiration Date N/A Date .94L.V2_CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspe te the components described in this Owner's Report during the period___ to/Ld/,/Q,7; and state that to the best of my knowledge and belief, the Owner has performed exam nations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section X1.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj or property damage or a loss of any kind arising from or connected with this inspection. 91474Jerome F Swan Commissions NC1524, N-I Inspector's i atre National Board, State, Province and Endorsements /Datez V1/7. , 6 Page 2 of 2 FORM NIS-2 OWNER'S REPOR. .OR REPAIR ! REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date January 2, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntarsville. NC 2807R 2a. Unit: 01 E1-2 03 rJShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. NIA Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1763015-46 Repair Organization Job #3b. NSM or MM #Pi AntV) A a A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME I11 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 10 No 2MCA-RN-3413 Duke Power N/A N/A N/A N/A 0 Replaced, Rl Replacement 0 Yes B 0 Repaired, C No 0 Replaced,[0 Replacement C Yes C C Repaired, 0 No 0 Replaced,[I Replacement C Yes D 0 Repaired, El No El Replaced,__ Replacement El Yes E E Repaired, El No El Replaced, C Replacement C Yes F C Repaired, C No C Replaced, 10 Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New installed hanger per MOD # MD200464.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptol Pressure _psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -.. ýý4w FL Grass Jr,QA Tech Specialist Date //Z74 .-,R Owner or Ov{ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by lHSB O,. have inspe te the components described in this Owner's Report during the period ,--,,/'/9 7"to 2o0:; and state that to the best of my knowledge and belief, the Owner has'pedrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -.Jerome F Swan Commissions NC1524, N-I Inspector ' ature National Board, State, Province and Endorsements / Date/ 2/LZ 9 Page 2 of 2 FORM NIS-2 OWNER'S REPOt,. FOR REPAIR / REPLACEMENT ACTIVITY As. Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 10, 2008 Sheet 1 of 1 2. Plant Address: Mc.Guire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 012 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3a. Work Order #: 1763617-32 Repair Organization Job #3b. NSM or MM #: MD201 471 4. (a) Identification of System: RN -Nuclear Service Water 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0l Repaired, 0l No 2-RN-VA-69 Walworth C59134 637 V-File# 714 1976 0 Replaced,__ Replacement 0 Yes B E Repaired, 0l No 2-RN-VA-69 Crane Nuclear D7265 N/A N/A 2008 El Replaced,]0 Replacement 0 Yes C -l Repaired, El No El Replaced,_ _._......_ _ E Replacement 0l Yes D El Repaired, El No El Replaced, El Replacement El Yes E El Repaired, El No El Replaced,_E Replacement El Yes F El Repaired, El No 0 Replaced,_E Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. X 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work-Replaced valve.8. Tests Conducted:Hydrostatic l] Pneumatic [] Nom. Operating Press. [] Other El ExemptO Pressure 100 psig Pressure psig -Pressure .psig 9. Remarks Functional performed per task 32.rest Temp. ' 74 °F rest Temp. OF rest Temp. OF (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed \ FL Grass Jr,QA Tech Specialist Owner or'Owner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period Z -/0 -0 9to S o-- OF; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this erome F Swan Commissions NC1524, N-I spetor's Srture National Board, State, Province and Endorsements (Page2 of 2 05/08/08 THU 09:05 FAX QA LAB[a 002 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES'As Required by the Provisions of the ASME Code, Section III, Division 1 Pg. 1 of 2 1. Manufactured and certified by CRANE Nuclear, Inc.. 860 Remington BoIlevard. Bolingbrook, IL 60440 (name and addresD of N CertiilcAli iOwer)2. Manufactured for Duke Energy Corporation, PO Box 1006. Charlotte, NC 28201-1015 (name ana o4nr4= or purrhase')

3. Location of installation McGulre Nuclear Station, 13225 Hagers Ferry Rd. HWY 73. Huntersvllle.

NC 26078.8985 J (name an eddress)4. Model No., Series No., or Type 5202-WE-SPL Drawing CC04304 Rev. C ! CRN N/A 5. ASME Code. Section III, Division 1. 1998 2000 2 1 --(adluon? (addanda date) (clasa) (Code C=a. no.)6. Pump or valve Gate Valve Nominal inlet size 8" Outlet size all 7. Material: (a) valve Body SA216 WCB (b) pump Casting Bonnet SA216 WC8 Cover (c)Body/Casing Serial No.SA193 B7 Disk SA351 CFSM Bolting SA194 2H " Bolting (a)Cert.Holder's Serial No.(b)Nat'l Board No.(d)Bonnet/Cover Serial No.(e)Disk Serial No.0_7265 L-' N/A D720277 D7214 721 D72"118 Supplement*aIinformition in the form of iist, tketcher. or drawing~s may be ussed provided (1) size 13 8 Ys4 x 11, (2) Informaetion In Items 1 through 4 on this Data Report Ir Included on each sheet. (3) each sheet Is numbered and the number of sheet.is recorded ai the top of this form-This form (E00037) mey be obtained from the Order Dept- ASME. 22 Law Drive. Box 2300, Fairfield. NJ 07007-2300. A -, n 3:ý QA LAB 0001.05/08/08 TH-I 09:06 FAX FORM NPV-1 (Back) --- P9. 2 of 2 Certificate Holder's Serial No.07265 (1)8 Design conditions

9. Cold working pressure 135 psi (pressure 05 'F (temperature) or valve pressure class 285 L// psi at 1 0oF 10. Hydrostatic test 450 315 psi psi. Disk differential lest pressure__.BRemaks:

Bopnne Stud G B Hr. #: d2031 H42 BonnetSt u Pi ean Clods: A105 Hr.#E723/i" 315 psi By-Pass Piping, SA106 GR B. Ht. #, 203614vtBy-Pass Piping Elbows: SA1 05. Ht. 9; 77230 -By-Pass Piping Valve S/N:, 071171-13 PO No. 00091378 PO Item # 0003, Duke Item 020-839 ýs'~CNI S/0 31 377-01 CERTIFICATION OF DESIGN Design Specifications certified by James Lamb, Jr. V"/ P.E. State NC Reg. no. 6005 Design Report certified by NIA P.2. State N/A Reg. no. N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Cods, Section II1, Division 1.N-2899 N Certificate of Authorization No.Date 03107/08 Name CRANE Nuclear. Inc. J Expires -September 24, 2008 Signed 1 -/ /r .ler o n i y .,as v -nck I , PE .' / Sr. Ouolliy Aesur~fnce EnlgIneor (N Ceroflcate NHoIer)CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT have inspected the pump. or valve, described in this Data Report on March 7. 2008 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section Ill. Division 1, By signing this Certificate, neither the inspector nor his employer makes any warranty, exprossed or implied, concerning the component described In this Data Report. Furthtermore, neither the Inspector nor his employer shall be liable in any manner fc any personal Injury or property damage or loss of any kind arslng from or connected with this inspection. Commissions Illinois 1005.(NeF l d. (lnol. endo'samems) and ahto or prov 4nd z.A 190606B FORM NIS-2 OWNER'S REPOh, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 la. Date 03/26/2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 0]2 03 OShared (specify Units )3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN Nuclear Service Water 3a. Work Order # : 01763617-60 Repair Organization Job #3b. NSM or MM #: MD20147D 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, [ENo 2-MCA-CA-5625 Duke Energy N/A N/A Hanger N/A 0 Replaced,_ _ _Replacement 0 Yes B 0 Repaired, [I No 0 Replaced,]0 Replacement r Yes C 0 Repaired, 0] No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No"- -,-0 Replaced, El Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,]0 Replacement C Yes F 0 Repaired, 0 No 0 Replaced,[0 Replacement 10 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Added Item 12, 1/2 Plate Per MD20147D 8. Tests Conducted:Hydrostatic El Pneumatic [] Nom. Operating Press. [1 Other OiExempt-Zi Pressure .psig Pressure -psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of. Authorization No. N/A Signed t,," F.R. Sorrow.QA Tech Support Owner or Owner's Designee, Title Expiration Date N/A Date 03/26. 2008 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period'- -o2- 8to 03. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuror property damage or a loss of any kind arising from or connected with this inspection.0n/ -. F Swan Commissions NC1524, N-I Inspector's Sign "ure National Board, State, Province and Endorsements Date3 --. 7 6 Page 2 of 2 FORM NIS-2 OWNER'S REPO, FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date Aoril 14, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haners Ferry Road. Huntersvillep NC 28078 2a. Unit: 01 02 103 OShared (specify Units "_)3. Work Performed By: Duke Power Companv Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: CA -Auxiliary Feedwater 3a. Work Order #: 1764228-32 Repair Organization Job #3b. NSM or MM #: MD201471 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section X1 Utilized for Repair Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamp'ed Installed (yes or no)A 0l Repaired, El No 2CA-VA-86 Walworth C61561 677 V File# 781 1976 0 Replaced,__ Replacement 01 Yes B El Repaired, 0 No 2CA-VA-86 Crane D7264 N/A N/A 2008 0 Replaced,.. 0 Replacement E0 Yes C *Repaired, 0l No El Replaced,[] Replacement 0l Yes D 0 Repaired, 0l No El Replaced,_ Replacement El Yes E 0l Repaired, El No 0 Replaced, El Replacement El Yes F 0l Repaired, 0 No El Replaced, 0] Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Cut out and replaced valve.8. Tests Conducted:Hydrostatic E] Pneumatic 0 Nom. Operating Press. I] Other LI Exempt[]Pressure 62 psig Test Temp. 60 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks Functional performed per task 32.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -, ,,4w2n FL Grass Jr,.QA Tech Specialist Date , 2 Owner orOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT hay~e inspected tlq components described in this Owner's Report during the period_-J-~to ..; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju r propertydamage or a loss of any kind arising from or connected with this inspection. J ,-,---=-'ome F Swan Commissions NC1524, N-I S Inspector's i n ure National Board, State, Province and Endorsements &, Page 2 of 2 05/08/08 THU 09:04 FAX , ALAB FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section III, Division I Pg. 1 of 2 1. Manufactured and certified by CRANE Nuclear, Inc.. 860 Remington Boulevard, Bolingbrook. IL 60440 V'(,~amo naO addfea5 of" N Co.1flCBI0 Nolder)2. Manufactured for Duke Energy Corporation, P0 Box 1006, Charlotte. NC 2M201-1015 (na.me end eddrvgs of ptvrchaso)

3. LocatIon of installation McGulre Nuclear Station. 13225 Hagers Ferry Rd. HWY 73. Huntersville, NC 28078-8985 V (nome and addraes&)4. Model No., Series No., or Type 5202-WE-SPL Drawing CC04304 Rev. C CRN N/A 5. ASME Code, Section iII, DivIsion 1: 1998 2000 2 -(edition) (addends deIe) (claes) (Coda Case no.)6. Pump or valve Gate Valve Nominal Inlet size a".,___ Outlet size _" 7. Materlal;SA193 87" (a) valve Body SA216 WCBV-/ Sonnet SA216 WC0 /V' Disk SA351 CFrMwv" BoIltIng SA194 2H , (b) pump Casting Cover Boiling -(a) (b) (c) (d) (e)Cert. Nat'l Body/Casing Bonnet/Cover Disk Holders Board Serial Serial Serial Serial No. No. No. No. No.D7264 / N/A D7201 v 07215 V 07217-Supplemental info~rmation in che formn of ll5Wt. sketchers, or drawings may be used provldcd (1) size is 6 Y2 x 11, (2) Informsflon In fterns I unrough 4 on this Dita Report is Included on each shael- (3) each sPeet Is nrunibarod 3nd the number of sheets is recorded ai the top of this form, This form (E00037) may be obtained from the Order DePL ASME, 22 Law Drie, Box 2300. FnIrfield.

NJ 07007.2300. [a002 05/08/08 THU 09:06 FAX QA LAB FORM NPV-1 (Back) -- Pg. 2 of 2 Certificate Holder's Serial No.07264 I/a Design conditions 135 psi /(pressure 95 OF (temperature) or valve pressure class (1)9. Cold working pressure 285 ,/ psi at 100°F 10. Hydrostatic test 450 ./ psi. Disk differential test pressure 11. Remarks: Bonnet Stud Heat Code: 1H62:/:-. ,Donnet Stud Nut Heat Code: 1 H65 BY-Pass Piping; SA106 GR B. HL #: 203644Y'By-P~ass Pipin2 Elbows: SA105. HI. #: 77230 " 315 psi By-Pass Pioino Valve SIN: 071171-12 ,,'EIV-Pass PiGirtc, Valve S/N: 071171-12 v-'PO No. 00091378 PO Item # 0003, Duke Item 02B-839 V'CNI S/0 31377-01 CERTIFICATION OF ODSIGN Design Speclflcatlons cartified by James Lamb, Jr. P.E. State NC Reg, no. 6005 Design Report certified by N/A P.E. state N/A Reg. no. N/A CERTIFICATE OF COMPLIANCE We cerUfy thai the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section III, Division 1.N Certificate of Authorization No.Date 03/10/08 Name N-2899 Expires .September 24, 2d08 Signed CRANE Nuclear, Inc.(N Cta.iflcste Holder)CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT have inspected the pump. or valve, described in this Data Report on _March 10, 2008 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code. Section IIl. Division 1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, conceming the component described in this Data Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection-Date 03/10/08 Signed Commissions Illinois 1005 (Nall 13d. (inc. endoftementlw lewd staetf or oov. aned no.)10 FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 1 a. Date February 25, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 3a. Work Order #: 3b. NSM or MM #: 1785753 Repair Organization Job #Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water MD100461 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME Il1 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial.No. National Board No. 'Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2RN404 Crane D5481 N/A Utc# 1819769 2006 0 Replaced, 0 Replacement 21 Yes B 0 Repaired, 0 No 2RN409 Crane D5894 N/A Utc# 1832819 2006 0 Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced, 0 Replacement 0] Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work_100461.Added pipingq and new valves 2RN404 and 2RN409 per MD 8. Tests Conducted:Hydrostatic El Pneumatic EJ Nom. Operating Press. 0 Other El Exemptl Pressure 62 psig Test Temp. 63 OF Pressure psig Test Temp. _ OF Pressure psig Test Temp. _ OF 9. Remarks Test Derformed Der Drocedure MP/O/A/7650/076.(Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed FL Grass Jr,QA Tech Specialist oýwner rowner's Designee, Title Expiration Date N/A Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 1-2 -3 to Z- .- a, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this fnspection. /erome F Swan Commissions NC1 524, N-I anspectoes Si.r ure National Board, State, Province and Endorsements SDate 01 a. zO 6 Page 2 of 2 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES.ýs Required by the Provisions of the ASME Code, Section III, Division 1*Corrected NPV-1 Pg. 1 of 2 1. Manufactured and certified by CRANE Nuclear, Inc., 860 Remington Boulevard, Bolingbrook. IL 60440 (name and address of N Certificate Hdde)2. Manufactured for Duke Energy Corporation, PO Box 1006, Charlotte, NC 28201-1015 (name and address of Purchaser)

3. Location of installation McGuire Nuclear Station. 13225 Ilagers Ferry Rd. HIWY 73, Huntersville, NC 28078-8985and address)4. Model No., Series No., or Type 5. ASME Code. Section III, Division 1: 47-1/2UF-SPL 1998 (edidtio)Drawing CC03984 Rev. C CRN N/A 2000 (addenda date)(class)N(A (Code Case no.)6. Pump or valve Gate Valve Nominal inlet size 6 (in.)Outlet size 6 (in.)7. Material: (a) valve Body SA351 CFBM -- Bonnet SA351 CF8M Disk SA351 CF8M -SA193 B8M Bolting SA194 8M (b) pump Casting _______Cover Bolting n oer (a) (b)Cert. Nat'l Holder's Board Serial No. No.05481 ' N/A (c)Body/Casing Serial No.05406 /" (d)Bonnet/Cover Serial No.05412 (e)Disk Serial No.05420 N* Supplemental infornmation in the form of lists, sketches.

or drawings may be used provided (1) size is 8 A x I1. (2) information in items I through 4 on this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this loan.This form (E00037) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007.2300. FORM NPV-1 (Back) --- Pg. 2 of 2 Certificate Holder's Serial No. 05481 8 Design conditions 135 psi 150 *F or valve pressure class (1)(pressure (temperature)

9. Cold working pressure 275 psi at 100°F 10. Hydrostatic test 425 psi. Disk differential test pressure 305 psi 11. Remarks: 'Corrected P.E. first name from James to Jesse.PO No. DP20357, P0 Item 0040. Duke Item No. 1MV-556 CNI SO No. 28451-04 CERTIFICATION OF DESIGN Design Specifications certified by *Jesse M. Hawkins P.E. State NC Reg. no. 20159 Design Report certified by N/A P.E. State NIA Reg. no. NIA CERTIFICATE OF COMPLIANCE We certify that the statements made in this report ar& correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section III. Division 1.N Certificate of Authorization No. N-2899 Expires September 24, 2008 Date 08109/06 Name CRANE Nuclear, Inc. Signed (N Cenficale Holder) t/(Joseph FfH.I i OA Engneer CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Bolter and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT have.inspected the pump, or valve, described In this Data Report on August 09, 2006 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section III, Division 1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report; Furthermore.'nelther the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.

Date 08/09/06 Signed * " 2 Q Commissions IL 1903 a) qNatt ad. Ond. erdoers.vwts) and stle or pri. and no.)ll~o;ýTd ýard (1) For manually operated valves only. FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section III, Division 1 Pg. 1 of 2 1. Manufactured and certified by CRANE Nuclear, Inc., 860 Remington Boulevard. Bolingbrook, IL 60440 (name and addreSS o0 N Certiticale Hoidef)2. Manufactured for Duke Energy Corporation, PO Box 1006, Charlotte, NC- 28201-1015

3. Location of installation

/McGuire Nuclear Station. 13225 Hageri Fern Rd. HWY 73, Hunfersville, NC 28078-8985 (name and address)4. Model No.. Series No.. or Type 47-1/2UF-SPL Drawing CC04072 Rev. B CRN NIA 5. ."ASME Code. Section I1l. Division 1: 1998'(edfion)dale)3 (class)N/A (Code C'ase no.)6, Pump or valve 7. Malerial: (a) valve Body-01) pump Casting , Cert.-Holder's.-erial No.7 Gate Valve Nominal inlet size 6 (in.)Outlet size -<<6* (in.),/SA216 WCB (b)Nat'l Board No.Bonnet v/SA216WCB Cover (c)Body/Casing Serial No.Disk /I'SA35t CF8M Bolting (d)Bonnet/Cover Serial No.A193 87 Bolting 2 ,:SA194 2H (e)Disk Serial No.J.N/A 1' 05896 Y' D5908 -'05916 N/A ..., 05897 V g5909 o-,_ D5917 N/A ', 05898 ,,_5910 _.O5918 NA 5899 0D59119__________________________________ 87zzz+/-3 12+/-S (8 4 V nation in items I through 4 on as form.300. Fairuield, NJ 07007-2300. X,.Supplemental information in Ithe form of lists. sketches, or drawings may be used provided (1) size is 8 A 1 x 11,(2) Inforr this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets Is recorded at the top of thi This form (E00037) may be obtained from the Order OepL ASME. 22 Law Drive. Box 23 FORM NPV-1.-(Back).---Pg. 2 of.2." Ce ficte iteHolder's .Serial No. /D5692 through 05895 6 Design conditions .135 .(pressure " psi V 95: *F 'o.-valve, pressure dass ..(1)9. Cold workingpessure V 285. psi ...10. Hydrostatic.test ..o-. 450.- -psi.. Disk diffe.-" PO No..000i6ý7, PO item 0007, Duke item No....MV-565 .CNI SýNb, 2940l-01-.",oltirigtýtuds Ht. # 230113/Nuts Ht. # B87035 er~et~ialtest pressure .V# 315 psi 4 CERTIFICATION OF DESIGN:Designv Specificationscertifted b Jesse M. Hawkins P.E. State NC Reg. no. .20159 ,Design Report certified by-... NIA P.E. State .;:N/A.,: Reg..no. NIA" CERrtF.ICAa. f05- COMPLIlA C..V.,,.a crniy that the. its made in this report.are.correcv and ,that ihis pump or valve contorms to U! rules tor construction cl e de.,SME Cod.e .. :Division 1: i.ijfificae 01i -r , iNo. N,2899 .... Expires Septeamer 24, 2008: V 2 rCRANE ." ciearl _ -4~t ~ J2/f sr~e i~Ce1rizt4~zeq*.. Jon..,re ij .S. A niee,'-'T F IC ATE. OFNSPECT40 -O '.: *.1 holding a v~lid~commissio~iis~u by Na~otat.oNoad or Bt)'itro'ediiPssefreessel Inspectorsa rnd the S-late or Proyince of Illinois and employed by .,- HSB.CT.Hartford. CT '3ve inspectedihe pump,,or,,valve, 0 aed in tttii .2006, and state that to the best of my knowledge and belief, ".Cert&ra*.ýl4der valve. in accordance-vhh the ASME Codc,,-Secbon Ill. Division 1.VA..By.;rWing this Certificate.. neither ~Ihe IrL~pector nor his~o ployer m;,akvq.4riy wan-anty.jxo ex~ q~ wir-n-ptd Iocrnn the~~¶~pinen desdb in this Data.4eot an~e neie p~or scr~hs e ll r 00a be liable in sny Manner for;aypen-mrial injury o( property, r1amage.,onlass o ldosn ~. ,o catAit2I~s~ln I/2/27/06 ýk4iecl 2 (1) For rc"nntieiy operated cl'aves only.,,,, .** ~.... 'A -. ý"FORM NIS-2 OWNER'S REPOR. .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code ,Section XI 1. Owner Address: Duke Power Company.:.-526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 25, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 1, ,12700 Haaers Ferr Road, Huntervile, NC 28078 2a. Unit: 01 02' 103 OShared (specify Units 3. Work. Perfrme .y DuePwr oon 3. Work Performed .By:.:' ,Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: KC -Component Cooling 3a. Work Order-# : 1801758 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: C N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: .-Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component .Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped-__Installed (yes or no)A 0 Repaired, 10 No 2MCA-KC-3332 Duke Power 3617 N/A N/A N/A 01 Replaced, 0 Replacement 0 Yes B 0 Repaired, 01 No 2MCA-KC-3332 Duke Power' 017 N/A N/A N/A 0 Replaced,[0 Replacement 0 Yes c 0 Repaired, 0 No" Replaced,___,_. 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes E .0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes.Page I of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of. Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exemptl--Pressure psig Test Temp., _F Pressure _psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass JrQA Tech Specialist Date 6wner w wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of: North Carolina and employed by.HSB CT have inspected the components described in this, Owner's Report during the period S.:%- i7/" -toi and state that to the. best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 1=50 )ý"Jerome F Swan Commissions NC1524, N-I inspector's Sig-ture National Board, State, Province and Endorsements -.% -1C uate..:._ -gS=?Page 2 of 2 FORM NIS-2 OWNER'S REPOR. .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 6. 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 102 03 rOShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/.A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1801841 Repair Organization Job #3b. NSM or MM #: N/A 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME II1 19711 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair /Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No.. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2MCA-RN-3019 Duke Power 3128 N/A N/A N/A 0 Replaced, I 1 0 Replacement 01 Yes B .0 0 Repaired, 0 No 2MCA-RN-3019 Duke Power 8515 N/A N/A N/A 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,]0 Replacement [0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement [I Yes E 0 Repaired, C No 0 Replaced, 0 Replacement C Yes F C3 Repaired, 0 No C Replaced,]0 Replacement 0 Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic El Pneumatic E- Nom. Operating Press. El Other El Exempt-Z Pressure -psig Test Temp. _ OF Pressure _ _ psig Test Temp. OF Pressure _________psig Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Grass Jr,QA Tech Specialist Date -v' 4e-p2.wa3 Ow wer or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the periodly-c o 5:' 7- 20Z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal. injury or property damage or a loss of any kind arising from or connected with this inspection. Lnspet-or-uerome F Swan Commissions NC1524, N-anspectoe ature National Board, State, Province and Endorsements Datea Page 2 of 2 FORM NIS-2 OWNER'S REPOR. ,-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1. Owner Address: Duke Power Company 526 S. Church Street, Charlotte, NC 28201-1006 la. Date 04/04/2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Haqers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 E12 03 DShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date:* N/A 4. (a) Identification of System: RN Nuclear Service Water 3a. Work Order # : 01802868 Repair Organization Job #3b. NSM or MM #: MD201740 4. (b) Class of System: C 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity:* 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0" Repaired, 13 No Piping Duke Energy N/A 60 2RN 1982 0l Replaced, 1__Replacement ElYes B El Repaired, El No El Replaced,[] Replacement 0 Yes C El Repaired, El No O Replaced, 0 Replacement [] Yes D 0] Repaired, 0l No 0 Replaced, 0l Replacement El Yes E El Repaired, El No El Replaced,_E Replacement El Yes F E Repaired, El No El Replaced,__ Replacement El Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Added 2" piping per MD201740, Welds RN2FW57-12,13,16, 17 &RN2FW13-6, 7,8,9, 10 8. Tests Conducted:Hydrostatic Li Pneumatic LI Nom. Operating Press. El Other LiExemptFI Pressure *101.1 psig Test Temp. *56 OF Pressure **101.1 psig Test Temp. **56.2 OF Pressure psig Test Temp. °_OF*Task 09 for valve 2RN-1072 at 101.1 psici & 56 'F- RN2FW57-12,13,16,17.

9. Remarks**Task 12 for valve 2RN-1073 at 101.1 psiq & 56.2 OF- RN2FW13-6,7,8,9,10 (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed F.R. Sorrow,QA Tech Support Owner or Owner's Designee, Title" Expiration Date N/A Date 04/04, 2008 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period-- OR to ý,- Y- OR'; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section X1.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Sinspection,., n,&I-e / .rome F Swan Commissions NC1524, N-I/ Inspector's Signature National Board, State, Province and Endorsements SDate /-t/ (Page 2 of 2 FORM NIS-2 OWNER'S REPOR. .OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Comoany 526 S. Church Street, Charlotte, NC 28201-1006 la. Date March 27, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 1"02 0-3 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 4. (a) Identification of System: RN -Nuclear Service Water 3a. Work Order #: 1802998 Repair Organization Job #3b. NSM or MM #4. (b) Class of System: C MD201697 5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity:

1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg SerialNo. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A 0 Repaired, 0 No 2-RN-VA-285 BNL A981103-4-21 N/A N/A 2000 0 Replaced, 1] 0 Replacement 0 Yes B 0 Repaired, 0 No 2-RN-VA-285 BNL A981103-4-13 N/A N/A 1999 0 Replaced,]0 Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,[0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,]0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,[] Replacement 0 Yes F 0 Repaired, 0 No 0 Replaced,]0 Replacement 0l Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced valve 8. Tests Conducted:Hydrostatic [] Pneumatic El Nom. Operating Press. l] Other El Exemptl Pressure _psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF 9. Remarks functional performed on task 06 per procedure MP/O/A/7700/045 (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 4W- FL Grass JrQA Tech Specialist Date ".' __Owner oirOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3- tJ- 6,' to q- 0-8; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed.or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. erome F Swan Commissions NC1524. N-I Inspector's'Sidnature National Board, State, Province and Endorsements Date L l -'/ n M Page 2 of 2 FORM NIS-2 OWNER'S REPOh. .-OR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1. Owner Address: Duke Power Companv 526 S. Church Street, Charlotte, NC 28201-1006 la. Date April 7, 2008 Sheet 1 of 1 2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Huntersville, NC 28078 2a. Unit: 01 02 03 OShared (specify Units 3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/_.A Expiration Date: N/A 4. (a) Identification of System: CA -Auxilary Feedwater 3a. Work Order #: 1805056 Repair Organization Job #3b. NSM or MM #: 4. (b) Class of System: C N/A 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair / Replacement Activity: 1998, 2000 Addenda (1998 through 2000 Addenda for Class MC and CC and their supports)6. Identification of Components: Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped Installed (yes or no)A P0 Repaired, RI No 2MCA-CA-128 Duke Power 112 N/A N/A N/A 0l Replaced,]0 Replacement 0 Yes B 0 Repaired, 0 No 2MCA-CA-128 Duke Power 20375 N/A N/A N/A [0 Replaced, Rl Replacement 0] Yes C 0] Repaired, [] No[] Replaced,]0 Replacement 0 Yes D ]0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes E 0] Repaired, [] No[I Replaced, 0] Replacement 0] Yes F[0 Repaired, 0] No[] Replaced,[] Replacement 0" Yes Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced snubber.8. Tests Conducted:Hydrostatic LI Pneumatic LI Nom. Operating Press. LI Other El Exemptl-Pressure psig Pressure psig Pressure psig Test Temp. OF Test Temp. OF Test Temp. OF 9. Remarks (Applicable Manufacturer's Data Reports to be attached)CERTIFICATE OF COMPLIANCE I certify that the sttements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed 4' FL Grass Jr,QA Tech Specialist ' Owner qorwner's Designee, Title Expiration Date N/A Date 4' 7 .t CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected tlIpcomponents described in this Owner's Report during the period i to Y- 7 -6 ' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.. _94ei 4 Jerome F Swan Commissions NC1524, N-I Insvector's Sdnature National Board, State, Province and Endorsements I Page 2 of 2 6.0 Pressure Testing First Period -Third 1O- Year Interval All system pressure test requirements have been satisfied for the First Inspection Period.Some pressure test zones were completed after EOC 17 but prior to March 1, 2007, the date ending the First Period. Those pressure test zones credited for the First Period which were not listed in the Summary Report for EOC 17 are shown in Table 6-1.Table 6-1 Detailed Class 2 -Ist Period Zones Not Listed in EOC17 Report VT-2 Examination Zone Number Boundary Dwg Completion Status Date 1 2BB-040L-B MC-ISIL-2580-01.00 1 st Period Complete 2/22/2007 2 2CA-040L-B MC-ISIL-2592-01.00 Ist Period Complete 212112007 3 2CA-043L-B MC-ISIL-2584-01.00 1 st Period Complete 2/22/2007 MC-ISIL-2591-01.01 1t Period Complete 2/22/2007 MC-ISIL-2592-01.00 1 st Period Complete 2/22/2007 MC-ISIL-2617-01.00 1 st Period Complete 2/22/2007 4 2FW-007L-B MC-ISIL-2554-03.00 1 st Period Complete 1/9/2007 MC-ISIL-2554-03.01 1 st Period Complete 1/9/2007 MC-ISIL-2561-01.00 1st Period Complete 1/9/2007 MC-ISIL-2562-03.00 1 st Period Complete 1/9/2007 MC-ISIL-2563-01.00 1 St Period Complete 1/9/2007 MC-ISIL-2571-01.00 1 st Period Complete 1/9/2007 5 2ND-009L-B MC-ISIL-2554-01.02 1t Period Complete 1/17/2007 MC-ISIL-2561-01.00 1 st Period Complete 1117/2007 MC-ISIL-2562-03.00 Ist Period Complete 1/17/2007 MC-ISIL-2562-03.01 1 st Period Complete 11/4/2006 MC-ISIL-2563-01.00 1 st Period Complete 1/17/2007 MC-ISIL-2571-01.00 1 Period Complete 1/17/2007 MC-ISIL-2572-01.00 1 st Period Complete 1/17/2007 6 2ND-01OL-B MC-ISIL-2561-01.00 1 st Period Complete 12/6/2006 MC-ISIL-2562-03.01 1 st Period Complete 12/6/2006 MC-ISIL-2563-01.00 I st Period Complete 12/6/2006 7 2NI-015L-B MC-ISIL-2562-03.00 1 st Period Complete 1/16/2007 8 2NI-016L-B MC-ISIL-2562-03.00 1st Period Complete 2/4/2006 EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 1 of 9 Revision 0 May 19, 2008 VT-2 Examination Zone Number Boundary Dwg Completion Status Date 9 2NI-017L-B MC-ISIL-2562-03.00 1 Period Complete 1/16/2007 MC-ISIL-2562-03.01 1st Period Complete 1/16/2007 10 2NI-018L-B MC-ISIL-2562-03.01 1 st Period Complete 1/16/2007 11 2NI-061L-B MC-ISIL-2562-01.00 1 st Period Complete 1/30/2007 12 2NI-062L-B MC-ISIL-2562-01.00 1 st Period Complete 1/30/2007 13 2NM-027L-B MC-ISIL-2572-03.00 1 st Period Complete 2/21/2007 14 2NS-019L-B MC-ISIL-2563-01.00 1 st Period Complete 1/15/2007 15 2NV-003L-B MC-ISIL-2554-01.00 1t Period Complete 21/21/2007 MC-ISIL-2554-01.01 1 st Period Complete 2/21/2007 MC-ISIL-2554-01.02 1st Period Complete 2/21/2007 MC-ISIL-2554-01.03 Ist Period Complete 11/8/2006 16 2NV-005L-B MC-ISIL-2554-01.02 1 st Period Complete 11/8/2006 17 2RN-044L-B MC-ISIL-2574-04.00 1 st Period Complete 121/82007 18 2SA-047L-B MC-ISIL-2593-01.02 1 st Period Complete 2/22/2007 19 2SM-040L-B MC-ISIL-2591-01.01 1 st Period Complete 2/21/2007 MC-ISIL-2593-01.00 1st Period Complete 2/21/2007 MC-ISIL-2593-01.03 1 st Period Complete 2/21/2007 EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 2 of 9 Revision 0 May 19, 2008 Second Period -Third 10-Year Interval Table 6-2 shows the number of Class 1 (Category B-P), Class 2 (Category C-H), and Risk Informed Segment (Category R-A) pressure tests zones completed from refueling outage EOC-17 through refueling outage EOC-18. There was no through-wall leakage observed during these pressure tests.Table 6-2 Outage Specific Summary Examination Category Test Requirement Total Zones Completed EOC18 B-P System Leakage Test (IWB-5220) 1 C-H System Leakage Test (IWC-5220) 3 R-A Risk Informed VT-2 for Socket Welds 66 Segments Table 6-3 shows a completion status for the number of pressure test zones conducted during the second period bf'the third ten-year interval.Table 6-3 Second Period Specific Summary Total Zones Total Zones (%) Zones Examination Test Requirement Required For Credited For Complete For Category This Period This Period This Period B-P System Leakage Test 3 1 33.33 %(IWB-5220) C-H System Leakage Test 34 3 8.82 %(IWC-5220) R-A System Leakage Test (66 Segments 66 33.33 %Each Refueling Outage) 198 For Period EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 3 of 9 Revision 0 May 19, 2008 The Class 1 (Category B-P) pressure test zone is required each refueling outage. Table 6-4 shows a completion status of the Class 1 (Category B-P) pressure test zone conducted during refueling cycle EOC18.Table 6-4 Detailed Class 1 Listing EOC18 Zone Completion Number Boundary Dwg Status EOC18 VT-2 Examination Date 2NC-001 L-A MC-ISIL-2553-01.00 Complete 4/10/2008 MC-ISIL-2553-02.00 Corn plete 4/10/2008 MC-ISIL-2553-02.01 Complete 4/10/2008 MC-ISIL-2554-01.00 Complete 4/10/2008 MC-ISIL-2554-01.01 Complete 4/10/2008 MC-ISIL-2554-01.02 Complete 4/10/2008 MC-I SIL-2561-01.00 Complete 4/10/2008 MC-ISIL-2562-01.00 Complete 4/10/2008 MC-ISIL-2562-02.00 Complete 4/10/2008 MC-ISIL-2562-02.01 Complete 4/10/2008 MC-ISIL-2562-03.00 Corn plete 4/10/2008 MC-ISIL-2562-03.01 Corn plete 4/10/2008 Class 2 (Category C-H) pressure test zones are required once each inspection period. Table 6-5 shows a completion status for the Class 2 (Category C-H) pressure tests required for the second period of the third ten-year interval.Table 6-5 Detailed Class 2 Second Period Listing VT-2 Examination Zone Number Boundary Dwg Completion Status Date 1 2BB-040L-B MC-ISIL-2580-01.00 Not Yet Tested N/A 2 2BB-074L-B MC-ISIL-2572-03.00 Not Yet Tested N/A MC-ISIL-2580-01.00 Not Yet Tested N/A MC-ISIL-2584-01.00 Not Yet Tested N/A 3 2CA-040L-B MC-ISIL-2592-01.00 Not Yet Tested N/A 4 2CA-043L-B MC-ISIL-2584-01.00 Not Yet Tested N/A MC-ISIL-2591-01.01 Not Yet Tested N/A MC-ISIL-2592-01.00 Not Yet Tested N/A MC-ISIL-2617-01.00 Not Yet Tested N/A EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 4 of 9 Revision 0 May 19, 2008 VT-2 Examination Zone Boundary Dwg Completion Status Date 5 2FW-007L-B MC-ISIL-2554-03.00 Not Yet Tested N/A MC-ISIL-2554-03.01 Not Yet Tested N/A MC-ISIL-2561-01.00 Not Yet Tested N/A MC-ISIL-2562-03.00 Not Yet Tested N/A MC-ISIL-2563-01.00 Not Yet Tested N/A MC-ISIL-2571-01.00 Not Yet Tested N/A 6 2ND-009L-B MC-ISIL-2554-01.02 Not Yet Tested N/A MC-ISIL-2561-01.00 Partial 3/1/2008 MC-ISIL-2562-03.00 Not Yet Tested N/A MC-ISIL-2562-03.01 Not Yet Tested N/A MC-ISIL-2563-01.00 Not Yet Tested N/A MC-ISIL-2571-01.00 Not Yet Tested N/A MC-ISIL-2572-01.00 Not Yet Tested N/A 7 2ND-01OL-B MC-ISIL-2561-01.00 Not Yet Tested N/A MC-ISIL-2562-03.01 Not Yet Tested N/A MC-ISIL-2563-01.00 Not Yet Tested N/A 8 2NI-012L-B MC-ISIL-2562-02.00 Complete 4/8/2008 MC-ISIL-2572-01.01 Complete 4/8/2008 9 2NI-013L-B MC-ISIL-2562-02.01 Complete 4/8/2008 MC-ISIL-2572-01.01 Complete 4/8/2008 10 2NI-014L-B MC-ISIL-2562-02.01 Complete 4/3/2008 MC-ISIL-2562-03.00 Complete 4/3/2008 11 2NI-015L-B MC-ISIL-2562-03.00 Not Yet Tested N/A 12 2NI-016L-B MC-ISIL-2562-03.00 Not Yet Tested N/A 13 2NI-017L-B MC-ISIL-2562-03.00 Not Yet Tested N/A MC-ISIL-2562-03.01 Not Yet Tested N/A 14 2NI-018L-B MC-ISIL-2562-03.01 Not Yet Tested N/A 15 2NI-060L-B MC-ISIL-2562-03.00 Not Yet Tested N/A 16 2NI-061L-B MC-ISIL-2562-01.00 Partial 3/7/2008 17 2NI-062L-B MC-ISIL-2562-01.00 Not Yet Tested N/A 18 2NM-026L-B MC-ISIL-2572-01.01 Not Yet Tested N/A EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 5 of 9 Revision 0 May 19, 2008 VT-2 Examination Zone Boundary Dwg Completion Status Date 19 2NM-027L-B MC-ISIL-2572-03.00 Not Yet Tested N/A 20 2NS-019L-B MC-ISIL-2563-01.00 Not Yet Tested N/A 21 2NS-020L-B MC-ISIL-2563-01 .00 Not Yet Tested N/A 22 2NV-003L-B MC-ISIL-2554-01.00 Partial 4/10/2008 MC-ISIL-2554-01.01 Partial 4/10/2008 MC-ISIL-2554-01.02 Not Yet Tested N/A MC-ISIL-2554-01.03 Partial 4/10/2008 23 2NV-004L-B MC-ISIL-1554-05.00 Not Yet Tested N/A MC-ISIL-2554-01.00 Not Yet Tested N/A MC-ISIL-2554-01.01 Partial 4/11/2008 MC-ISIL-2554-01.02 Not Yet Tested N/A MC-ISIL-2554-02.00 Not Yet Tested N/A MC-ISIL-2554-02.01 Not Yet Tested N/A MC-ISIL-2554-03.00 Partial 4/11/2008 MC-ISIL-2554-03.01 Partial 4/11/2008 MC-ISIL-2561-01.00 Partial 4/11/2008 MC-ISIL-2562-01.00 Complete 4/11/2008 MC-ISIL-2562-03.00 Partial 4/11/2008 24 2NV-005L-B MC-ISIL-2554-01.02 Partial 4/10/2008 25 2NV-006L-B MC-ISIL-2554-03.00 Partial 4/29/2008 26 2NV-008L-B MC-ISIL-2554-01.02 Not Yet Tested N/A 27 2NV-011 L-B MC-ISIL-2554-03.01 Partial 4/11/2008 28 2RN-044L-B MC-ISIL-2574-04.00 Partial 4/3/2008 29 2RV-048L-B MC-ISIL-2604-03.00 Partial 3/6/2008 30 2SA-047L-B MC-ISIL-2593-01.02 Not Yet Tested N/A 31 2SM-040L-B MC-ISIL-2591-01.01 Not Yet Tested N/A MC-ISIL-2593-01.00 Not Yet Tested N/A MC-ISIL-2593-01.03 Not Yet Tested N/A 32 2SM-045L-B MC-ISIL-2593-01.00 Not Yet Tested N/A MC-ISIL-2593-01.02 Not Yet Tested N/A MC-ISIL-2593-01.03 Not Yet Tested N/A EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 6 of 9 Revision 0 May 19, 2008 VT-2 Examination Zone Boundary Dwg Completion Status Date 33 2SM-046L-B MC-ISIL-2593-01.00 Not Yet Tested N/A MC-ISIL-2593-01.03 Not Yet Tested N/A 34 2YA-063LB MC-SIL2617-01.00 Not Yet Tested N/A Risk Informed Segments (Category R-A) that receive a pressure test are required each refueling outage. Table 6-6 shows a completion status of the Risk Informed Segment pressure test zones conducted during refueling cycle EOC18.Table 6-6 Detailed Risk Informed Pressure Test Listing EOC18 Zone Segment Completion EOC18 VT-2 Number Boundary Dwg Number Status Examination Date 1 2NC-001L-A MC-ISIL-2553-01.00 NC-18 Complete 4/10/2008 2 NC-19 Complete 4/10/2008 3 NC-20 Complete 4/10/2008 4 NC-21 Complete 4/10/2008 5 NC-23 Complete 4/10/2008 6 NC-86 1 Complete 4/10/2008 7 NC-89 Complete 4/10/2008 8 NC-90 Complete 4/10/2008 9 MC-ISIL-2553-02.00 NC-054 Complete 4/10/2008 10 NC-055 Complete 4/10/2008 11 NC-056 Complete 4/10/2008 12 MC-ISIL-2554-01.00 NV-033A Complete 4/10/2008 13 NV-033B Complete 4/10/2008 14 NV-034A Complete 4/10/2008 15 NV-034B Complete 4/10/2008 16 NV-037 Complete 4/10/2008 17 NV-038 Complete 4/10/2008 18 NV-041A Complete 4/10/2008 19 NV-041 B Complete 4/10/2008 20 NV-042A Complete 4/10/2008 21 NV-042B Complete 4/10/2008 1 Part of this segment is also shown on drawing MC-ISIL-2553-02.01. EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 7 of 9 Revision 0 May 19, 2008 EOC18 Zone Segment Completion EOC18 VT-2 Number Boundary Dwg Number Status Examination Date 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 2NC-001 L-A MC-ISIL-2554-01.01 NV-030A Complete 4/10/2008 NV-030B Complete 4/10/2008 NV-032A Complete 4/10/2008 NV-032B Complete 4/10/2008 NV-035 Complete 4/10/2008 NV-036 Complete 4/10/2008 NV-039A Complete 4/10/2008 NV-039B Complete 4/10/2008 NV-040A Complete 4/10/2008 NV-040B Comolete 4/10/2008 4 4 MC-ISIL-2562-01.00 NI-068 Complete 4/10/2008 NI-069 Complete 4/10/2008 NI-070 Complete 4/10/2008 NI-071 Comrlete 4/10/2008 2ND-009L-B MC-ISIL-2561-01.00 ND-008C Complete 3/1/2008 ND-009C Complete 3/1/2008 2N1-061L-B MC-ISIL-2562-01.00 NI-063B Complete 3/7/2008 2NV-003L-B MC-ISIL-2554-01.03 2NV026 2 Complete 4/10/2008 2NV027 3 Complete 4/10/2008 NV-028 3 Complete 4/10/2008 NV-029 4 Complete 4/10/2008 2NV-004L-B MC-ISIL-2554-01.01 NV-020AD Complete 4/11/2008 MC-ISIL-2554-03.00 NV-01 9AA 4 Complete 4/11/2008 NV-0I9AB Complete 4/11/2008 NV-019AD Complete 4/11/2008 NV-019B Complete 4/11/2008 NV-019D Complete 4/11/2008 NV-020AA Complete 4/11/2008 NV-020AB Complete 4/11/2008 NV-020AE Complete 4/11/2008 NV-021A Complete 4/11/2008 NV-021B Complete 4/11/2008 MC-ISIL-2554-03.01 NV-002AB 5 Complete 4/11/2008 NV-002D Complete 4/11/2008 NV-01 9C Complete 4/11/2008 NV-019E Complete 4/11/2008 2NV-005L-B MC-ISIL-2554-01.02 NV-080A Complete 4/10/2008 NV-080B Complete 4/10/2008 2 Part of this segment is also shown on drawing MC-ISIL-2554-01.01. 3 Part of this segment is also shown on drawing MC-ISIL-2554-01.00. 4 Part of this segment is also shown on drawing MC-ISIL-2554-03.01. 5 Part of this segment is also shown on drawing MC-ISIL-2554-03.00. EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 8 of 9 Revision 0 May 19, 2008 EOC18 Zone Segment Completion EOC18 VT-2 Number Boundary Dwg Number Status Examination Date 60 2NV-005L-B MC-ISIL-2554-01.02 NV-084A Complete 4/10/2008 61 NV-084B Complete 4/10/2008 62 NV-084C Complete 4/10/2008 63 2NV-006L-B MC-ISIL-2554-03.00 NV-002C 6 Complete 4/29/2008 64 NV- 08A 6 Complete 4/29/2008 65 NV- 096 Complete 4129/2008 66 2NV-011L-B MC-ISIL-2554-03.01 NV-011 A 7 Complete 4/11/2008 Section 6 Prepared By: Date: Sectop, rbve"A _Date: 4z )A69 6 The NV PD Pump was out of service during outage 2EOC-18 (ref. PIP M-08-1705). Therefore, RI Segments NV-002C, NV-008A and NV-109 were tested when the pump was placed in service for fuel cycle 2EOC-19.7 Part of this segment is also part of zone 2NV-004L-B. EOC 18 / Outage 3 McGuire Unit 2 Section 6 -Third Ten-Year Interval Page 9 of 9 Revision 0 May 19, 2008}}