Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
IR 05000324/1986011 | 13 March 1986 | Enforcement Conference Repts 50-324/86-11 & 50-325/86-10 on 860219.Major Areas Discussed:Alleged Matl False Statements in Repts Responding to TMI Item III.D.3.4 Re Control Room Habitability | |
IR 05000324/1986012 | 21 April 1986 | Insp Repts 50-324/86-12 & 50-325/86-11 on 860301-31. Violations Noted:Inadequate Acceptance Test After Core Spray Valve Motor Operator Replacement & Inadequate Procedure for Standby Liquid Control Sys Surveillance Test | |
IR 05000324/1986013 | 20 May 1986 | Safety Insp Repts 50-324/86-13 & 50-325/86-12 During Apr 1986.No Violations or Deviations Noted.Major Areas Inspected:Maint & Surveillance Observation,Operational Safety Verification & Diesel Generator Fuel Oil Leaks | Hydrostatic |
IR 05000324/1986014 | 16 May 1986 | Insp Repts 50-324/86-14 & 50-325/86-13 on 860430-0506.No Violations or Deviations Noted.Major Areas Inspected: Containment Integrated Leak Rate Test & Followup of Previously Identified Items | |
IR 05000324/1986017 | 9 July 1986 | Insp Repts 50-324/86-17 & 50-325/86-16 on 860609-13.No Violation or Deviation Noted.Major Areas inspected:post- Refueling Initial Criticality & Tests (Unit 2) & Routine Core Performance Surveillance | Shutdown Margin Overtravel |
IR 05000324/1986019 | 22 July 1986 | Insp Repts 50-324/86-19 & 50-325/86-18 on 860708-10.No Violations or Deviations Noted.Major Areas Inspected: Allegations Re Conduct of Operations.Allegations Unsubstantiated | High Radiation Area Locked High Radiation Area |
IR 05000324/1986020 | 22 August 1986 | Partially Withheld Insp Repts 50-324/86-20 & 50-325/86-19 on 860721-24 (Ref 10CFR2.790 & 73.21).No Noncompliance Noted. Major Areas Inspected:Physical Security Plans & Implementing Procedures & Mgt Effectiveness | |
IR 05000324/1986021 | 18 September 1986 | Insp Repts 50-325/86-20 & 50-324/86-21 on 860804-08. Violation Noted:Failure to Ensure Waste Shipment Contained Less than 1% Free Standing Liquid & No Unabsorbed Oil | High Radiation Area Process Control Program |
IR 05000324/1986022 | 29 September 1986 | Insp Repts 50-324/86-22 & 50-325/86-21 on 860801-31.No Violation or Deviation Noted.Major Areas Inspected:Maint Observation,Surveillance Observation,Operational Safety Verification & Onsite Review Committee | Packing leak Stroke time |
IR 05000324/1986024 | 22 October 1986 | Partially Withheld Physical Security Insp Repts 50-324/86-24 & 50-325/86-23 (Ref 10CFR2.790 & 73.21).No Noncompliance Noted.Major Areas Inspected:Physical Barriers & Safeguards Contingency Plan Implementation Review | Safeguards Contingency Plan |
IR 05000324/1986026 | 21 October 1986 | Insp Repts 50-324/86-26 & 50-325/86-25 on 860922-25. Violation Noted:Failure to Provide Adequate First Aid Training to Emergency Personnel Designated to Provide Svc | Siren |
IR 05000324/1986027 | 30 October 1986 | Insp Repts 50-324/86-27 & 50-325/86-26 on 860915-19.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Radiological Environ Protection & Info Notices | |
IR 05000324/1986028 | 27 October 1986 | Insp Repts 50-324/86-28 & 50-325/86-27 on 860922-26.No Violations or Deviations Noted.Major Areas inspected:post- Refueling Startup Tests & Closeout of Bulletins & Open Items | |
IR 05000324/1986029 | 1 December 1986 | Insp Repts 50-324/86-29 & 50-325/86-28 on 861020-24.No Violations Noted.Major Areas Inspected:Electrical, Instrumentation & Control Maint Activities | Emergency Lighting |
IR 05000324/1986030 | 2 December 1986 | Safety Insp Repts 50-324/86-30 & 50-325/86-29 on 861005-31. Violation Noted:Failure to Properly Perform Temporary Rev | Boric Acid Half scram Squib VT-2 Integrated leak rate test Hourly Fire Watch Overspeed trip |
IR 05000324/1986031 | 1 December 1986 | Insp Repts 50-324/86-31 & 50-325/86-30 on 861103-07.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection/Prevention & Followup on Previously Identified Insp Items | Safe Shutdown Fire Barrier Fire Protection Program Fire Watch |
IR 05000324/1986032 | 26 November 1986 | Insp Repts 50-324/86-32 & 50-325/86-31 on 861103-07.No Violations or Deviations Noted.Major Areas Inspected: Inservice Testing of Pumps & Valves & Part 21 & IE Info Notices Followup | Stroke time |
IR 05000324/1986033 | 22 December 1986 | Safety Insp Repts 50-325/86-32 & 50-324/86-33 on 861101-30. No Violations or Deviations Noted.Major Areas Inspected: Followup on Previous Enforcement Matters,Maint Observation, Surveillance Observation & Operational Safety Verification | Probabilistic Risk Assessment VT-2 Scram Discharge Volume |
IR 05000324/1986034 | 6 February 1987 | Safety Insp Repts 50-324/86-34 & 50-325/86-33 on 861201-31 & 870114.Violation Noted:Failure to Provide Adequate Instructions for Sealing Pressure Switches | Scaffolding |
IR 05000324/1986035 | 22 December 1986 | Insp Repts 50-324/86-35 & 50-325/86-34 on 861209-11.No Violations or Deviations Noted.Major Areas Inspected: Observation & Evaluation of Key Emergency Organizational Functions & Locations During Emergency Exercise | Fire Watch |
IR 05000324/1987001 | 21 January 1987 | Insp Repts 50-325/87-01 & 50-324/87-01 on 870105-08.No Violations or Deviations Identified.Major Areas Inspected: Assessment of Licensee Preparation for & Performance of Hydrogen Water Chemistry Tests | Intergranular Stress Corrosion Cracking |
IR 05000324/1987003 | 26 March 1987 | Safety Insp Repts 50-324/87-03 & 50-325/87-03 on 870201-28, 0303-04.Violation Noted:Failure to Maintain Unit 2 PWR Fuel Storage Capacity | Anchor Darling |
IR 05000324/1987005 | 30 March 1987 | Insp Repts 50-324/87-05 & 50-325/87-05 on 870223-27.No Violations or Deviations Noted.Major Areas Inspected:Action on Previously Identified Insp Findings | |
IR 05000324/1987006 | 29 April 1987 | Insp Repts 50-324/87-06 & 50-325/87-06 on 870301-0403.No Violation or Deviation Noted.Major Areas Inspected:Followup on Previous Enforcements & Unresolved Items & Circulars,Rept Review,Maint,Surveillance,Esf Sys & Operational Safety | Reactor Vessel Water Level Fire Barrier High Energy Line Break Local Leak Rate Testing |
IR 05000324/1987007 | 14 April 1987 | Insp Repts 50-324/87-07 & 50-325/87-07 on 870330-0403.No Violations or Deviations Noted.Major Areas Inspected:Qc & Confirmatory Measures,Including Lab QC Program,Procedures & Instructions.Criteria & Results for Measurements Encl | Offsite Dose Calculation Manual |
IR 05000324/1987008 | 8 April 1987 | Insp Repts 50-325/87-08 & 50-324/87-08 on 870316-20.No Violations or Deviations Noted.Major Areas Inspected: Inservice Insp Work Activities & Weld Overlay Repair Welding | Weld Overlay Nondestructive Examination Stress corrosion cracking |
IR 05000324/1987009 | 3 April 1987 | Radiation Protection Insp Repts 50-324/87-09 & 50-325/87-09 on 870323-27.No Violations or Deviations Noted.Major Areas Inspected:Organization & Mgt Controls,Training & Qualifications & Internal/External Exposure Control | High Radiation Area Locked High Radiation Area Intergranular Stress Corrosion Cracking |
IR 05000324/1987012 | 30 June 1987 | Insp Repts 50-324/87-12 & 50-325/87-12 on 870504-08.Major Areas Inspected:Area of Review of Operational Events,Control Room Activities,Maint,Training,Lers & Closeout of Open Items | Reactor Vessel Water Level Fire Watch Water hammer |
IR 05000324/1987014 | 9 June 1987 | Insp Repts 50-325/87-14 & 50-324/87-14 on 870511-15.No Violations or Deviations Noted.Insp Conducted Per Temporary Instruction 2500/12 Re Insp of Actions Taken by Licensees & Applicants of Mark I & II Containments | Weld Overlay Intergranular Stress Corrosion Cracking |
IR 05000324/1987015 | 7 July 1987 | Insp Repts 50-325/87-15 & 50-324/87-15 on 870515-22.No Violations or Deviations Noted.Major Areas Inspected: Witnessing of Unit 1 Primary Containment Integrated Leak Rate Test & Followup Insp of Outstanding Item for Unit 2 | Post Accident Monitoring |
IR 05000324/1987016 | 24 June 1987 | Insp Repts 50-324/87-16 & 50-325/87-16 on 870527-29.No Violations or Deviations Noted.Major Areas Inspected:Ie Bulletin 80-11 & Snubber Surveillance Program | |
IR 05000324/1987017 | 28 July 1987 | Safety Insp Repts 50-324/87-17 & 50-325/87-17 on 870601-30. Violation Noted.Major Areas Inspected:Previous Enforcement Matters,Maint & Surveillance Observation,Operational Safety Verification,Ie Bulletin Followup & Refueling Startup Insp | Fitness for Duty Shutdown Margin Overtravel |
IR 05000324/1987018 | 21 July 1987 | Insp Repts 50-324/87-18 & 50-325/87-18 on 870608-12.No Violations or Deviations Noted.Major Areas Inspected:Visual Insp Procedures,Inservice Insp Data & Evaluations,Previous Enforcement Matters,Lers & IE Bulletins | Weld Overlay Nondestructive Examination Intergranular Stress Corrosion Cracking Stress corrosion cracking Water hammer |
IR 05000324/1987020 | 26 August 1987 | Safety Insp Repts 50-324/87-20 & 50-325/87-20 on 870701- 0806.Violations Noted.Major Areas Inspected:Followup on Previous Enforcement Matters,Maint & Surveillance Observations & Operational Safety Verification | Loctite Overspeed trip Water hammer |
IR 05000324/1987021 | 28 July 1987 | Insp Repts 50-324/87-21 & 50-325/87-21 on 870706-10.No Violations or Deviations Noted.Major Areas Inspected:Actions Taken to Implement Generic Ltr 84-11 Re Insps of BWR Stainless Steel Piping | Weld Overlay Intergranular Stress Corrosion Cracking Unidentified leakage |
IR 05000324/1987023 | 30 July 1987 | Insp Repts 50-325/87-23 & 50-324/87-23 on 870713-17 & 23. Violation Noted.Major Areas Inspected:Emergency Preparedness Program | Siren |
IR 05000324/1987024 | 25 September 1987 | Safety Insp Repts 50-324/87-24 & 50-325/87-24 on 870807-31. No Violations or Deviations Noted.Major Areas Inspected: Maint & Surveillance Observations,Operational Safety verification,in-ofc LER Review & Onsite Followup of Events | |
IR 05000324/1987025 | 20 August 1987 | Insp Repts 50-324/87-25 & 50-325/87-25 on 870727-31.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection/Prevention,Followup on Previously Identified Insp Items & Employee Concerns | Safe Shutdown Fire Barrier Hydrostatic Exemption Request Fire Protection Program Fire Watch |
IR 05000324/1987027 | 10 September 1987 | Insp Repts 50-324/87-27 & 50-325/87-27 on 870810-14.No Violations or Deviations Noted.Major Areas Inspected:Core Physics Testing & Followup on Open Items | Shutdown Margin Local Leak Rate Testing |
IR 05000324/1987028 | 3 September 1987 | Insp Repts 50-325/87-28 & 50-324/87-28 on 870817-21.No Violations or Deviations Noted.Major Areas Inspected: Organization & Mgt Controls,Training & Qualifications, External & Internal Exposure Control & Surveys | Locked High Radiation Area Overexposure |
IR 05000324/1987029 | 28 September 1987 | Insp Repts 50-324/87-29 & 50-325/87-29 on 870831-0904.No Violations or Deviations Noted.Major Areas Inspected:Exam of Svc Water Sys Monitoring Programs & Scram Discharge Vol Capability SER Compliance | Scram Discharge Volume Operability Determination |
IR 05000324/1987031 | 18 November 1987 | Insp Repts 50-324/87-31 & 50-325/87-32 on 870914-18 & 0928-1002.Violations Noted.Major Areas Inspected:Qa Effectiveness | Packing leak |
IR 05000324/1987032 | 27 September 1987 | Insp Repts 50-324/87-32 & 50-325/87-33 on 870914-18.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Radwaste Mgt,Radiological Effluent Monitoring Instrumenation,Tmi Actions Items & Inspector Followup Items | Grab sample Offsite Dose Calculation Manual Intergranular Stress Corrosion Cracking Process Control Program |
IR 05000324/1987033 | 14 October 1987 | Insp Repts 50-324/87-33 & 50-325/87-34 on 870921-25.No Violations or Deviations Noted.Major Areas Inspected: Emergency Preparedness | |
IR 05000324/1987034 | 22 September 1987 | Insp Rept 50-324/87-34 on 870914-15.No Violations or Deviations Noted.Major Areas Inspected:Ie Bulletin 85-003 Re motor-operated Valve Common Mode Failures During Plant Transient Due to Improper Switch Settings | |
IR 05000324/1987036 | 22 October 1987 | Partially Withheld Insp Repts 50-324/87-36 & 50-325/87-35 on 870929-1002 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Mgt Effectiveness,Security Program, Testing & Maint,Alarm Stations & Personnel Training | |
IR 05000324/1987037 | 24 November 1987 | Safety Insp Repts 50-324/87-37 & 50-325/87-36 on 871001-31. Violation Noted.Major Areas Inspected:Maint & Surveillance Observation,Physical Security,Tmi Action Item & Limitorque Actuator Environ Qualification Deficiencies | Fire Barrier High Energy Line Break Scram Discharge Volume Pressure Boundary Leakage Fire Watch Hourly Fire Watch Unidentified leakage Overspeed trip Operational leakage |
IR 05000324/1987039 | 4 December 1987 | Insp Repts 50-324/87-39 & 50-325/87-38 on 871102-06. Violation Noted.Major Areas Inspected:Failure to Promptly Correct Tech Spec Requirement Re Gages | Stroke time |
IR 05000324/1987041 | 27 November 1987 | Insp Repts 50-324/87-41 & 50-325/87-40 on 871116-18.No Violation or Deviation Noted.Major Areas Inspected:Licensee Annual Emergency Preparedness Exercise | Scram Discharge Volume Fuel cladding Fire Protection Program |
IR 05000324/1988002 | 4 March 1988 | Insp Repts 50-324/88-02 & 50-325/88-02 on 880111-15,19-22 & 0131-0205.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp of Welds,Piping & Components for IGSCC & Weld Overlay Repair Welding | Weld Overlay Intergranular Stress Corrosion Cracking Stress corrosion cracking Liquid penetrant Dissimilar Metal Weld |