ML19305E44318 March 1980Final Deficiency Rept Re Switchgear Breaker Position Switch Operator Defect.All 33 Breaker Switch Operators Have Been Replaced W/More Rigid Design Assemblies
ML19305E63128 April 1980Final Rept on Deficiency Re Unsatisfactory Impact Tests on Pipe Penetration Assemblies 3 & 4 Supplied by Associated Piping & Engineering Corp.Matl Returned to Vendor for Mod &/Or Replacement.Test Results Now AcceptableHydrostatic
ML19308A22229 December 1978Addl Interim Report of Significant Const Deficiency 9, Noncompliance to Welding Requirements for HVAC Seismic Support Hanger to Embedded Plates. in Addition to Immediate Corrective Actions,Hanger to Plate Welds Are Being RepairedNondestructive Examination
Liquid penetrant
ML19309A79418 March 1980Final Rept of Significant Deficiency 11,re Switchgear Breaker Position Switch Operator defect.Thirty-three Breaker Position Switch Operators Replaced W/Newly Designed GE Assemblies.Operators Have Guides Preventing Bending
ML19309B89731 March 1980Final Deficiency Rept Re Noncompliance to Welding Requirements for Heating,Ventilation & Air Conditioning Seismic Support Hanger to Embedded Plates.All Affected Welds Repaired & Insps Documented for QA FilesTime of Discovery
ML19309C84911 February 1980Interim Deficiency Rept Re Surface Indication on Reactor Pressure Vessel.Grinding Rework to Investigate Indication Will Commence 800215 & Be Completed by 800228
ML19309F2018 April 1980Final Rept of Significant Const Deficiency 13 Re Defects in Containment Bldg Dome Concrete.Caused by Improper Random Vibration Due to Vibrators That Were Inadequate in Size & Number.Qualified Job Superintendent Will Be Provided
ML19309F9288 April 1980Supplementary Deficiency Rept Re AH90 & NH90 Series Actuators Supplied by Itt General Controls.Itt General Control Will Supply Actuator Force Values & Torque & Damper Torque Values Will Be Compared.Customer List Encl
ML19309G37230 April 1980Final Rept of Significant Const Deficiency 14 Re Unsatisfactory Impact Tests on Pipe Penetration Assemblies 3 & 4.Cause Not Stated.Scope of QC Personnel Indoctrination Increased Re Emphasis on Preparation of Qc/Qa RecordsHydrostatic
ML19309G7662 May 1980Potential Significant Deficiency Rept Re Discrepancy in Procurement of Weld Wire.Wire Used in post-weld,heat-treated Weldments Was Tested for Only as-welded Condition
ML19309G79318 April 1980Final Rept of Significant Const Deficiency 14 Re Unsatisfactory Impact Tests on Pipe Penetration Assemblies. QC Training Program Provides More Emphasis on Preparation of Qc/Qa Records.Penetration Assemblies Were ReturnedHydrostatic
ML19309H95115 May 1980Interim Deficiency Rept 3 Re post-tensioning Anchorhead Failure.Acceptance Criteria Being Developed by Inryco,Inc to Establish Acceptability of Replacement Anchorheads.Testing Completed by 800630,w/final Rept Submitted at That Time
ML19318A05110 June 1980Final Deficiency Re Loose Control Element Drive Mechanism Guide cones.C-E Secured & Tightened Each Guide Cone to 60 Ft Lb Torque Value.Completed Spot & Tack Welds Visually Inspected & Approved
ML19318D2382 July 1980Interim Rept of Significant Const Deficiency 17 Re Base Metal Defects in Main Steam & Feedwater Containment Penetration Anchors.Evaluation Underway to Establish Repair Techniques.Final Rept Will Be Forwarded by 810301
ML19320A60127 June 1980Final Significant Const Deficiency Rept 16 Re Control Element Drive Mechanism Guide Cones & Penetration Assemblies Interface.Offset Condition Exists Which Could Produce Interference on Control Assembly ShaftLiquid penetrant
ML19320A80227 June 1980Interim Deficiency Rept Re Failure of post-tensioning Anchorheads.Generally Concurs W/Inryco 800530 Rept.All Category B Heat Treat Lots Will Be Tested.Replacement Anchorheads from Accepted Heat Treat Lots Will Be Installed
ML19321A8968 July 1980Interim Part 21 Rept Re Defective Itt Actuators in Dampers. Customer Notification Encl.Jobs Classified Nonnuclear safety-related Are Not Reportable.Actuators Supplied for Other Jobs Are Considered Purchaser Responsibility
ML19322A15727 December 1978Bolted Connections That Connect Horizontal Channel Sections of the Termination Subassembly to the Header Mounting Brackets Were Loose or Disengaged.Termination sub-assembly Connections Were Redesigned to Use Welded Pemnuts
ML19323D52931 March 1980Final Rept of Significant Const Deficiency 9,re Welding of Heating,Ventilation & Air Conditioning Seismic Support Hangers to Embedded Plates.Caused by Engineering Error. Contractor Initiated Repairs for Hanger to Embedded PlatesTime of Discovery
ML19323F81921 May 1980Final Const Deficiency Rept 5 Re Impeller Shaft Retaining Mechanism Failure in Low Presssure Safety Injection Pumps, Discovered on 780216.Exact Cause Not Known But May Be Due to Gasket Deterioration.Locking Devices Modified
ML19323G13725 April 1980Interim Deficiency Rept Re Primary Containment Relief Valves Potential Significant Deficiency.Determination of Corrective Action Scheduled for 800522
ML19323G42323 May 1980Second Interim Rept Re Potential Deficiency in Primary Containment Relief Valves.Initial Analysis Indicates Hinge Block Mounting Studs Inadequate.Revised Analysis by 800630
ML19323J15810 June 1980Final Rept of Significant Const Deficiency 7 Re Loose Control Element Drive Mechanism Guide cones.C-E Completed Corrective Repairs During Wk Ending 800315.Guide Cones Were Firmly Locked in Place,Torqued & Spot Welded
ML19325C95229 September 1989Part 21 Rept Re Potential Common Failure of SMB-000 & SMB-00 Cam Type Torque Switches Supplied Prior to 1981 & 1976. Vendor Recommends That Switch W/Fiber Spacer Be Replaced
ML19325E08616 October 1989Followup Part 21 Rept Re Class 1E Battery Chargers W/ Transformers Running at Temps Exceeding Those Used in Qualification Rept When Operating at or Near Full Load Rating of Equipment.Listed Corrective Actions Underway
ML19330A37720 June 1980Part 21 Report Re Installed Tech-Sil,Inc Matls Containing 5% Gel Which Cannot Be Traced in Original Formulation.Cause Not Stated.Unused Matl Has Been Returned to Vendor. Noncompliance Rept 9 Encl
ML19330A61423 July 1980Deficiency Rept Re Intermittent Contact Operation of W-2 Switch.Util Will Not Implement Interim Fix Unless No Permanent Solution Is Available Prior to Fuel Load.Util Will Monitor Westinghouse Recommendations
ML19330A79720 June 1980Part 21 Rept Re Potential Interference in Full Function of Bergen-Paterson Strut Assembly W/Pacific Scientific Co Mechanical Shock Arrestor.Customers Will Be Notified of Affected Items & Recommended Solution
ML19330B28125 June 1980Potential Significant Deficiency Rept Re Primary Containment Relief Valves Supplied by Gpe Controls.Bechtel Has Completed Review of Revised Stress Analysis Calculations.Expected Completion Date of Actions Is 800815
ML19330B66431 July 1980Final Deficiency Rept for Significant Const Deficiency 15 Re Procedural & Performance Deficiencies in Ultrasonic Testing of Structural Welds.Caused by Mfg Procedural & Ebasco ASME Insp Deficiencies.Mfg & Insp Responsibilities EstablishedCoatings
ML19332A6742 September 1980Part 21 Rept Re Con/Chem Epoxy Surfacer Sys.Suppls 800812 Ltr Re Subj Item Reported by Bechtel Power Corp.Will Advise of Schedule Dates of Completion When Bechtel Engineering Studies Finalized
ML19332C58320 November 1989Part 21 Rept Re Misapplication of Magnetrol Level Switches Supplied by GE W/Hpci & RCIC Turbine Assemblies.Switches Declared Inoperable & Electrically Disconnected.Magnetrol Will Modify Spare Level Switch Assemblies
ML19337A67019 September 1980Final Interim Deficiency Rept Re MSIV Leakage Control Sys E32 Being installed.E23 Equipment Cannot Meet Functional Requirements to Relieve Steamline Pressure.Mods Being Implemented & Will Be Completed Prior to Fuel Load
ML19337B34520 August 1980Interim Deficiency Rept Re Primary Containment Relief Valves Supplied by Gpe Controls.Bechtel Review Showed Calculation Assumptions Re Seismic Analysis Require Further Vendor Justification.Next Rept by 801024
ML19338C78929 August 1980Deficiency Rept Re Cracking Problem in Electrical Wiring Conduit.Caused by Overbending Below Original Published Min Inside Bend Diameters.Will Replace Conduits Installed at Bend Diameters Below Min Inside Bend Diameter
ML19338E9501 October 1980Rept on Significant Const Deficiency 18 Re Flexible Liquid Tight Wiring Conduit Covering Failure (Anaconda).Deficiency Under Evaluation.Rept Will Be Submitted by 801017
ML19339A1722 October 1980Interim Deficiency Rept Re Cracks in Insulation of Certain Feed Through Conductors of Entrance or Exit of Epoxy Module Portion of Penetration.Rework Procedure Has Not Been Formally Submitted.Supplemental Rept Expected by 810101
ML19340D05515 December 1980Interim Significant Deficiency Rept 19,Target Rock Motor Operated Valves-Bushing Not Staked. High Pressure Safety Injection Header Shutoff Valve Found W/Loose Bushing. Bushings Will Be Corrected & Insp by 810630
ML19340D88024 October 1980Interim Deficiency Rept Re Primary Containment Relief Valves at Facility,Initially Reported on 800326.Expected Conclusion of Investigation Has Been Postponed Until 801205
ML19340E1323 December 1980Significant Deficiency Rept,Originally Reported on 800326, Re Primary Containment Vacuum Relief Valves.Concludes That Subj Bolting Is Designed within Appropriate Stress Allowables & Conforms W/Spec 10855-M-150(Q)
ML19341A39919 January 1981Final Deficiency Rept Re Electrical Termination Lug Design. Insp of Control Room Panels & Replacement of Improper Lugs Completed
ML19341A40119 January 1981Final Deficiency Rept Re Valve Yoke Matl in Anchor/Darling Valves,Initially Reported on 801218.Schedule Has Been Established for Shipment of 138 New Yokes Between 810227 & 0424.Defective Yokes Will Be Replaced & Destroyed
ML19341D01627 February 1981Interim Deficiency Rept 17,originally Reported on 800705,re Base Metal Defects in Main Steam & Feedwater Containment Penetration Anchors.Existing Cracks Being Repaired.Lug & Stiffener Joint Welding Procedures to Be Modified
ML19343A65410 November 1980Interim Deficiency Rept,Originally Reported on 801009,re Two Class 2 Carbon Steel Pipes Supplied by Labarge Inc Lacking Radiography of Longitudinal Weld Seam.Matl Returned to Labarge.Next Rept to Be Submitted on 801209Nondestructive Examination
ML19343A66112 November 1980Deficiency Rept Suppl,Originally Reported on 801010,re Spool Weld Buildup Insufficient Exam.Bechtel Power Corp Currently Determining Corrective Actions.Reportability Determination Will Be Completed by 801212
ML19343B44010 December 1980Interim Deficiency Rept Re Two Pieces of Carbon Steel Pipe Found to Be Lacking Radiography of Longitudinal Weld Seam. Investigation Expected to Be Completed 810123 Instead of 801209
ML19343B80723 December 1980Interim Significant Const Deficiency Rept 21 Re Linear Indications in Electrical Cable Tray Seismic Support Clips Initially Reported in 801124 Telcon.Performance of Clips Under Actual Loading Conditions Will Be Investigated
ML19343B80823 December 1980Final Deficiency Rept Re Class I Vessel Control Element Drive Mechanism Motor Housings Mfg W/O Final Surface Penetrant Nondestructive Examination,Initially Reported in 801126 Telcon.Deficiency Determined Not ReportableNon-Destructive Examination
Nondestructive Examination
ML19343C49216 March 1981Interim Deficiency Rept (Significant Const Deficiency 25) Re GE Circuit Breakers AKR-30 & AKR-50 Failure to Close.Ge Will Supply Parts & Technical Supervision to Replace Bearing Assemblies.Final Rept Will Be Submitted on 811130Safe Shutdown
ML19344B4426 October 1980Part 21 Rept Re Use of Con/Chem Coating Sys in Safety Related Areas.Provides Clarified Statement Re Item 6 of Previous Ltr