LER 80-016/03L-0:on 800307,at Completion of Fuel Loading & W/Core Alterations Still underway,SI-65 Was Not Performed. Caused by Misinterpretation of Tech Specs by Personnel.No Corrective Actions Necessary
ML19309C867
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 04/03/1980
From: Record D
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19309C865 List:
References
LER-80-016-03L, LER-80-16-3L, NUDOCS 8004090336
Download: ML19309C867 (2)


Text

m.

d

    • f * *
  • L' % *e*JI.'L k :.ra ht t s;,-t \ i . *
  • Cr ' '.* a l'

u ..t '  !' 4. i t txic

'r . ., .

c. . . ,,, ....t z.i : .....s.w..,,. .

['_ .

T

  • N' f.N,Pjl ' ' 0 0. ' .' .O ' O O'O O - 0.I Of. ' 4 i 1.1.1.

. .., i l i l .14 '._ _' _.t r',

O'3.0.17'8 0y I' f Lj . 0 ' 5 ' O. 0 ' O. '. 3 . 2 7 ',0 ; 410_i3_: 8_ ' 0_ ,-

m-

".-"-t . .

At the completion of fuel loading but with core alterations still Dij L__ underway, upper internals were installed and RCCA drag testing was

p. . r L. . performed; SI-65 (which fulfills LCO 3.9.2 and 3.9.5) was not. . . _ _ _ _

f_~h } L._ performed._,LCO 3. 9.2 and 3. 9.5 were not fulfilled from the evening _

(g.3 y shift of 3/5/80 until the day shift of 3/7/80. There was no danger to the health and safety of the public. Previous occurrences - none.

F_m. i _ . _ . . . . . _ _ _ . . . . . . _ _ . . _ , _ _ _ . . _ . . _ _ . , , , .

r,a] t , ,

=; ,

. _ ., ~9 .u.3 0' .~1 1 zlzl'.

LA.J u LA_M ZZ Z! Z' ZR, [.j E LZ R

.,. c: a. . . . . . . . ..

O..:w.!bY

~ h .. 4t ,

t

h. ' 1 < 61!'

0 la [ 3] .

g h, p r,,s I _'

,d';

..g At t. a ,

( t iy ' ' [,.. Nb. , ya Nip. [f9799

~

k!..,[ jhu- (Z, if , iZ!' [0 0' 0 3 d t c:a .n .n.u.n - . , n, Lra i Licensed operators were instructed to perform S1-65 during Core FTjL Alterations,. Previously, they misinterpreted ,the Tech. Specs. and

{~E] L_-.though,t SI-65 was applicable only during fuel movement. This was _ ,

rir-I L_ the first occurrence of this event and no further corrective actions

. I,-~3 i- were thought necessary.

, ,. .g .

[T i] LHj : . l01 0:0 ! N/A L .. i_. Operator observation B 4

....,_('.>'

[.'~_[]LZj LZ,' (_N/A . . _ _ . _ _ _ . , _

N/A . _ _ _ . .

N/A

[i~i 1 0 0 0: 'Or.

[. .I ' [ _0 0

. - .1 0. .' . N/A . . . . . . . . . . . . . _ . . . - . . _ . - _ - _

I'-  !

[~]..1.t..%

. i ._N/A .. . . . . . _ _ .

l g t..t --' '

F^i.--] i6--N.

-- N/A . .- . . . . _ _ _ _

...i. . Daniel _J. Record. _ .____._ ,. . . ,.a 615-8422-5.203 - -.-

80040g0 DN

6 Tann2e ss Valley Authority

Sequoyah Nuclear Plant LER SUPPLEPENTAL INFORMATION SQRO-50-327/8016 Technical Specifications Involved 3.9.2 and 3.9.5 Reported Under Technical Specification 6.9.1.13.c Date of Occurrence
3/5/80 Evening Shift until 3/7/80 Day Shift - Unit 1 Identification and Description of Occurrence:

Operations personnel, in reviewing Technical Specifications, determined a the plant had not performed SI-65 (which fulfills 3.9.2 and 3.9.5) during Core Alterations.

Conditions Prior to Occurrence:

Unit 1 in Mode 6 following initial core loading. Upper internals installed and RCCA drag testing in progress.

Action specified in the Technical Specification Surveillance Requirements met due to inoperable equiptent. Describe.

N/A Apparent Cause of Occurrence:

l Misinterpretation of Technical Specification requirements.

l Analysis of Occurrence:

There was no hazard to the public health or safety.

Corrective Action:

SI-65, which satisfies Surveillance Requirements 4.9.2.a and 4.9.5, was immediately initiated.

Failure Data:

N/A i