{{#Wiki_filter:I lominion Energy Kewaunee, Inc.I)(i;l iorninion Boulevard, Glen Allen.VA 2>il!November13,2009UnitedStates NuclearRegulatoryCommission Attention:
{{#Wiki_filter:I lominion Energy Kewaunee, Inc.
DocumentControlDesk Washington,DC20555-0001 DOlllinio..**SerialNo.:09-680 LR/DEA RODocketNo.:50-305LicenseNo.:DPR-43 DOMINION ENERGY KEWAUNEE, INC.KEWAUNEE POWER STATION RESPONSE TO REQUEST FOR ADDITIONAL INFORMATIONFORTHE REVIEWOFTHE KEWAUNEE POWERSTATIONLICENSERENEWAL AGING MANAGEMENT REVIEW RESULTSByletterdated October13,2009(Reference1),theNRCprovidedarequestforadditionalinformationregardingtheaging managementreviewresultsincludedinthelicenserenewalapplication(LRA)forKewauneePowerStation(KPS)(Reference 2).TheNRC staffindicatedthatresponsestoeachrequestforadditionalinformation(RAls)areneededtocompletethereviewoftheKPSLRA.
I)(i; l iorninion Boulevard, Glen Allen. VA 2>il!                           DOlllinio..**
Attachment1tothisletterprovidestheDominionEnergyKewauneeInc.(DEK)responsestoeachoftheRAlssubmittedbytheNRC staffinReference1.DEKlettersdated August6,2009(Reference3)andAugust17,2009 (Reference 4)providedresponsestoNRCRAls2.3.3.18-1andB2.1.14-3,respectively.DEK subsequentlydeterminedthatclarificationstotheseRAIresponseswereneeded.Additionally,therevisedresponsetoRAIB2.1.14-3includestheadditionofException5whichwas previouslyidentifiedforremovalintheoriginalresponse.
November 13, 2009 United States Nuclear Regulatory Commission                            Serial No.: 09-680 Attention: Document Control Desk                                        LR/DEA       RO Washington, DC 20555-0001                                              Docket No.: 50-305 License No.: DPR-43 DOMINION ENERGY KEWAUNEE, INC.
Attachment2tothisletterprovidesthenecessaryclarificationsandreplacestheoriginal responses toRAls2.3.3.18-1and 82.1.14-3intheirentirety.Theon-siteportionoftheRegionIIILicenseRenewalInspectionwasconductedfromAugust17,2009throughAugust21,2009andAugust31,2009through September 4,2009.Duringthisinspection,DEKindicatedthattwoadditional exceptionswouldbecreatedfortheCompressedAirMonitoringprogram.These exceptionsareprovidedin Attachment
KEWAUNEE POWER STATION RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE KEWAUNEE POWER STATION LICENSE RENEWAL APPLICATION-AGING MANAGEMENT REVIEW RESULTS By letter dated October 13, 2009 (Reference 1), the NRC provided a request for additional information regarding the aging management review results included in the license renewal application (LRA) for Kewaunee Power Station (KPS) (Reference 2).
: 3.
The NRC staff indicated that responses to each request for additional information (RAls) are needed to complete the review of the KPS LRA. Attachment 1 to this letter provides the Dominion Energy Kewaunee Inc. (DEK) responses to each of the RAls submitted by the NRC staff in Reference 1.
My Commission Expires:SerialNo.09-680DocketNo.50-305Page2of4Shouldyouhaveanyquestionsregardingthissubmittal,pleasecontactMr.PaulC.Aitkenat(804)273-2818.Verytrulyyours,WilliamR.MatthewsSeniorVicePresident-NuclearOperations COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledgedbeforeme,inandforthe CountyandState aforesaid, todaybyWilliamR.Matthews,whois Senior Vice President-Nuclear Operations ofDominionEnergyKewaunee,Inc.Hehasaffirmedbeforemethatheisduly authorized toexecuteandfiletheforegoing documentonbehalfofthatCompany,andthatthe statements in the documentaretruetothebestofhis knowledgeandbelief.
DEK letters dated August 6, 2009 (Reference 3) and August 17, 2009 (Reference 4) provided responses to NRC RAls 2.3.3.18-1 and B2.1.14-3, respectively.                     DEK subsequently determined that clarifications to these RAI responses were needed.
Acknowledgedbeforemethis 13"[JIday ofY(Ot0nd1l"AJ
Additionally, the revised response to RAI B2.1.14-3 includes the addition of Exception 5 which was previously identified for removal in the original response. Attachment 2 to this letter provides the necessary clarifications and replaces the original responses to RAls 2.3.3.18-1 and 82.1.14-3 in their entirety.
,2009.,.I;L beL'x: ,J-fvtu<Notary Public-VICKIL.HULL Notary PublicCommonwealth 0'VIrginia140542My Commission Expires May31,2010-SerialNo.09-680DocketNo.50-305Page3of 4  
The on-site portion of the Region III License Renewal Inspection was conducted from August 17, 2009 through August 21, 2009 and August 31, 2009 through September 4, 2009. During this inspection, DEK indicated that two additional exceptions would be created for the Compressed Air Monitoring program. These exceptions are provided in .
 
Serial No. 09-680 Docket No. 50-305 Page 2 of 4 Should you have any questions regarding this submittal, please contact Mr. Paul C.
Aitken at (804) 273-2818.
Very truly yours,
&./.&#xa3;V&#xa5;~<
William R. Matthews Senior Vice President - Nuclear Operations COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledged before me, in and for the County and State aforesaid, today by William R. Matthews, who is Senior Vice President - Nuclear Operations of Dominion Energy Kewaunee, Inc. He has affirmed before me that he is duly authorized to execute and file the foregoing document on behalf of that Company, and that the statements in the document are true to the best of his knowledge and belief.
Acknowledged before me this    13 "[JIday ofY(Ot0nd1l"AJ     ,2009.               ,
My Commission Expires:            . I;L               beL' x: ,J-fvtu<
Notary Public
                                                            -     VICKI L. HULL Notary Public            ~
Commonwealth 140542 0' VIrginia  ~
                                                                                            ~
My Commission Expires May 31, 2010
                                                                                    -
 
Serial No. 09-680 Docket No. 50-305 Page 3 of 4


==References:==
==References:==
1.LetterfromSamuelHernandez(NRC)toDavidA.Heacock(DEK),"Request for AdditionalInformationfortheReviewoftheKewauneePowerStationLicense Renewal Application-Aging ManagementReviewResults(TACNo.MD9408)," dated October13,2009.[ADAMSAccessionNo.ML092390063]2.LetterfromD.
: 1. Letter from Samuel Hernandez (NRC) to David A. Heacock (DEK), "Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Review Results (TAC No. MD9408),"
A.Christian(DEK)toNRC,"KewauneePowerStation Application forRenewedOperatingLicense,"datedAugust12,2008.[ADAMS Accession No.ML082341020]3.LetterfromD.A.Christian(DEK)toNRC,"ResponsetoRequestforAdditionalInformationfortheReviewoftheKewauneePowerStationLicenseRenewal Application-StructuresScoping/FireProtection,"dated August6,2009.[ADAMS AccessionNo.ML092190757]4.LetterfromD.A.Christian(DEK)toNRC,"ResponsetoRequestfor AdditionalInformationfortheReviewoftheKewauneePowerStationLicenseRenewal Application-Aging ManagementPrograms,"datedAugust17,2009.[ADAMSAccessionNo.ML092320093]
dated October 13, 2009. [ADAMS Accession No. ML092390063]
Attachments:1.ResponsetoRequestforAdditionalInformationRegardingAging ManagementReviewResults2.RevisedResponsesforRAls2.3.3.18-1and 82.1.14-3 3.AdditionalExceptionsforCompressedAirMonitoringProgram Commitmentsmadeinthisletter:1.TheAlloy600InspectionsprograminLRAAppendixA,USARSupplement,SectionA2.1.1,willberevisedtochangetheProgramDescription consistentwiththeresponsetoRAI82.1.1.TherevisedProgramDescriptionisproposedtosupportapprovaloftherenewedoperatinglicense,andmaychangeduringtheNRCreview period.2.LicenseRenewal Commitment30,identifiedinLRATableA6.0-1,willberevised consistentwiththerevisedresponsetoRAI 82.1.14-3describedin Attachment3tothisletter.Therevised commitmentisproposedtosupportapprovaloftherenewedoperatinglicense,andmaychangeduringtheNRCreviewperiod.
: 2. Letter from D. A. Christian (DEK) to NRC, "Kewaunee Power Station Application for Renewed Operating License," dated August 12, 2008. [ADAMS Accession No.
3.AdditionalinformationwillbeaddedtoLRAAppendixA,USARSupplement,SectionsA4.2.1andA3.6,consistentwiththeresponsetoRAI4.2.1-1regardingneutronfluence.Theadditionalinformationisproposedtosupportapprovaloftherenewedoperatinglicense,andmaychangeduringtheNRCreviewperiod.
ML082341020]
cc:U.S.Nuclear Regulatory Commission Regional Administrator,RegionIII 2443 Warrenville Road Suite 210Lisle,IL 60532-4532Mr.P.S.Tam, Senior Project Manager U.S.Nuclear Regulatory Commission One WhiteFlint,MailStop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738Ms.V.Perin Environmental Project Manager U.S.Nuclear Regulatory CommissionMailStop 0-11 F1 Washington,DC20555-0001Mr.Q.S.Hernandez License Renewal Project Manager U.S.Nuclear Regulatory CommissionMailStop 0-11 F1 Washington,DC20555-0001 NRC Senior Resident Inspector Kewaunee Power Station N490 Highway 42 Kewaunee,WI54216 Public Service Commission of Wisconsin Electric DivisionP.O.Box7854 Madison,WI53707 David Hardtke Chairman-TownofCarlton E2334 Lakeshore Road Kewaunee,WI54216SerialNo.09-680 Docket No.50-305Page4of4 SerialNo.09-680 Docket No.50-305 ATTACHMENT 1 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING AGING MANAGEMENT REVIEW RESULTS KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.
: 3. Letter from D. A. Christian (DEK) to NRC, "Response to Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Structures Scoping / Fire Protection," dated August 6, 2009. [ADAMS Accession No. ML092190757]
SerialNo.09-680DocketNo.50-305 Attachment1/Page1of40 Request for Additional Information(RAI)3.1.2.2.6 Reactor Vessel Internals  
: 4. Letter from D. A. Christian (DEK) to NRC, "Response to Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Programs," dated August 17, 2009. [ADAMS Accession No. ML092320093]
Attachments:
: 1. Response to Request for Additional Information Regarding Aging Management Review Results
: 2. Revised Responses for RAls 2.3.3.18-1 and 82.1.14-3
: 3. Additional Exceptions for Compressed Air Monitoring Program Commitments made in this letter:
: 1. The Alloy 600 Inspections program in LRA Appendix A, USAR Supplement, Section A2.1.1, will be revised to change the Program Description consistent with the response to RAI 82.1.1. The revised Program Description is proposed to support approval of the renewed operating license, and may change during the NRC review period.
: 2. License Renewal Commitment 30, identified in LRA Table A6.0-1, will be revised consistent with the revised response to RAI 82.1.14-3 described in Attachment 3 to this letter. The revised commitment is proposed to support approval of the renewed operating license, and may change during the NRC review period.
: 3. Additional information will be added to LRA Appendix A, USAR Supplement, Sections A4.2.1 and A3.6, consistent with the response to RAI 4.2.1-1 regarding neutron fluence. The additional information is proposed to support approval of the renewed operating license, and may change during the NRC review period.
 
Serial No. 09-680 Docket No. 50-305 Page 4 of 4 cc: U.S. Nuclear Regulatory Commission Regional Administrator, Region III 2443 Warrenville Road Suite 210 Lisle, IL 60532-4532 Mr. P. S. Tam, Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint, Mail Stop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738 Ms. V. Perin Environmental Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-11 F1 Washington, DC 20555-0001 Mr. Q. S. Hernandez License Renewal Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-11 F1 Washington, DC 20555-0001 NRC Senior Resident Inspector Kewaunee Power Station N490 Highway 42 Kewaunee, WI 54216 Public Service Commission of Wisconsin Electric Division P.O. Box 7854 Madison, WI 53707 David Hardtke Chairman - Town of Carlton E2334 Lakeshore Road Kewaunee, WI 54216
 
Serial No. 09-680 Docket No. 50-305 ATTACHMENT 1 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING AGING MANAGEMENT REVIEW RESULTS KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 1 of 40 Request for Additional Information (RAI) 3.1.2.2.6 Reactor Vessel Internals


==Background:==
==Background:==


License Renewal Application(LRA)Table 3.1.2-2referencesGeneric Aging Lessons Learned (GALL)Aging ManagementReview(AMR)ItemIV.B2-9 andlistsloss offracturetoughnessduetoneutronirradiation embrittlement and void swelling(anaging mechanism discussedinLRASection 3.1.2.2.6)asone of the aging mechanisms affectingthefollowing RV internals:
License Renewal Application (LRA) Table 3.1.2-2 references Generic Aging Lessons Learned (GALL) Aging Management Review (AMR) Item IV.B2-9 and lists loss of fracture toughness due to neutron irradiation embrittlement and void swelling (an aging mechanism discussed in LRA Section 3.1.2.2.6) as one of the aging mechanisms affecting the following RV internals: head & vessel alignment pins, rod cluster control assembly (RCCA) guide tube bolts, RCCA guide tube support pins, upper core plate alignment pins, upper fuel alignment pins, upper support column bolts, upper support plate assembly, upper core plate, and hold-down spring. However, GALL Table IV.B2 (Item IV.B2-9 and other items relevant to these RV internals) does not consider the above-mentioned aging mechanism applicable to these RV internals.
head&vessel alignmentpins,rod cluster control assembly(RCCA)guidetubebolts,RCCAguidetube support pins, uppercoreplate alignment pins, upper fuel alignment pins, upper supportcolumnbolts, upper supportplateassembly, uppercoreplate, andhold-downspring.However,GALLTableIV.B2(ItemIV.B2-9 and other items relevanttothese RVinternals)does not consider the above-mentioned aging mechanism applicabletothese RV internals.
Request:
Request:Pleaseindicateifthelistingof aging mechanisms (loss of fracture toughnessduetoneutronirradiation embrittlement andvoidswelling)fortheabove mentioned RVinternalswas prompted by plant-specificexperienceorifthiswasduetoa conservative approach.DEK ResponseTheidentificationoflossoffracture toughnessduetoneutronirradiation embrittlementandvoidswellingforthehead
Please indicate if the listing of aging mechanisms (loss of fracture toughness due to neutron irradiation embrittlement and void swelling) for the above mentioned RV internals was prompted by plant-specific experience or if this was due to a conservative approach.
&vesselalignmentpins,rodclustercontrolassembly(RCCA)guidetubebolts,RCCAguidetubesupportpins,uppercoreplatealignmentpins,upperfuelalignmentpins,uppersupportcolumnbolts,uppersupportplateassembly,uppercoreplate,andhold-downspringwasduetoa conservative approach.Thereisno plant-specificoperatingexperiencethatindicatestheseaging mechanismsareactuallyoccurringforthesecomponents.
DEK Response The identification of loss of fracture toughness due to neutron irradiation embrittlement and void swelling for the head & vessel alignment pins, rod cluster control assembly (RCCA) guide tube bolts, RCCA guide tube support pins, upper core plate alignment pins, upper fuel alignment pins, upper support column bolts, upper support plate assembly, upper core plate, and hold-down spring was due to a conservative approach.
SerialNo.09-680 Docket No.50-305 Attachment 1/Page2of40 RAI3.5.2.3-1
There is no plant-specific operating experience that indicates these aging mechanisms are actually occurring for these components.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 2 of 40 RAI3.5.2.3-1


==Background:==
==Background:==
InLRATable3.0-1,RawWaterhasbeen defined as waterthathas,"notbeen demineralized or chemically treated to any significant extent, andincludesintake waterfromLake Michigan."Alsotherawwaterincludes treatedwaterthatleaksfrom plantsystemsintofloordrains andsumps.LRATables 3.5.2-1 through 3.5.2-14 include severallineitemswiththe environment listed asrawwater.Theseitemshavebeen assigned StandardNoteH,whichstates,"aging effectnotinNUREG-1801forthis component, material and environment combination." Issue:Rawwater chemistrymaybesuchthatitcancausedegradationforconcrete,steel, and other material.Reguest: 1.Explainthe past and presentrawwater monitoring activities anddiscusstheresultsinterms of the aggressiveness of water.2.Ifrawwaterisnotmonitored,what inspection/monitoring criteria of the Structures MonitoringProgramareorwillbefollowedto ensurethattheeffects ofagingwillbe adequately managed sothatthe intendedfunction(s)willbe maintained consistentwiththeCLBforthe period of extended operation.
 
DEK Response 1.Periodic monitoringoftheraw intake waterfromLake Michigan,whichisafresh waterlake,isnot presently being performedandhasnotbeen performedinthepast.
In LRA Table 3.0-1, Raw Water has been defined as water that has, "not been demineralized or chemically treated to any significant extent, and includes intake water from Lake Michigan." Also the raw water includes treated water that leaks from plant systems into floor drains and sumps. LRA Tables 3.5.2-1 through 3.5.2-14 include several line items with the environment listed as raw water. These items have been assigned Standard Note H, which states, "aging effect not in NUREG-1801 for this component, material and environment combination."
However, the analysisoflake water samples takenin1971,2004,and2006, indicated averagereadingsof8.18forpH,8.94ppmfor chlorides, and 22.63ppmfor sulfates.Also,a2004 analysis of water samplestakenfromthetwodeep potable water wells locatedonsite indicated average readingsof7.5forpH,34ppmfor chlorides,and640ppmfor sulfates.Basedonthe above results, intake water from Lake Michigan and potable well water are considered non-aggressive to concrete or steel.Nopastor present periodic monitoring activitieshavebeen performed for drains and sumps to identify chemicals considered aggressive to concreteorsteel.However, water collected in floor drains and sumps is monitored for gamma, tritium, and suspended solids.Additionally,ifahigh sumplevelis detectedinthe Reactor ContainmentVessel,thesump watermaybe testedforboron, conductivity,andpHtohelp determine the leakage source.
Issue:
SerialNo.09-680DocketNo.50-305 Attachment1/Page3of40ThesourcesofwaterthatleakfromplantsystemsintofloordrainsandsumpsiseitherfromLakeMichigan,potablewells,ortreatedwatersystems.Theseareall considered non-aggressivetoconcreteandsteel.
Raw water chemistry may be such that it can cause degradation for concrete, steel, and other material.
Consequently,thesumpsarenot periodicallymonitoredfor aggressiveconstituents.Additionally,identifiedleaksdonotcontinuefortheextensiveperiodoftimerequiredfor degradationofconcrete,steel,andothermaterialtooccur.2.Thegroundwaterchemistryfor inaccessiblebelowgradeconcreteis periodicallymonitoredinaccordancewiththe StructuresMonitoringProgram(SMP).However,asstatedabove,rawwateris considered non-aggressiveandis therefore not periodicallymonitored.Furthermore,allstructuresorstructural memberswithinthescopeoflicenserenewalthatareexposedtoarawwater environment areaccessibleforvisualinspectionandtheapplicableagingeffectsaremanagedbytheSMP,regardlessofthe compositionoftherawwater.Therefore,theeffectsofagingforin-scopestructuresorstructural membersexposedtorawwaterwillbe adequatelymanagedsothattheintendedfunction(s)willbe maintained consistentwiththeCLBfortheperiodofextendedoperation.
Reguest:
SerialNo.09-680DocketNo.50-305 Attachment1/Page4of40 RAI 3.5.2.3-2  
: 1. Explain the past and present raw water monitoring activities and discuss the results in terms of the aggressiveness of water.
: 2. If raw water is not monitored, what inspection/monitoring criteria of the Structures Monitoring Program are or will be followed to ensure that the effects of aging will be adequately managed so that the intended function(s) will be maintained consistent with the CLB for the period of extended operation.
DEK Response
: 1. Periodic monitoring of the raw intake water from Lake Michigan, which is a fresh water lake, is not presently being performed and has not been performed in the past.
However, the analysis of lake water samples taken in 1971, 2004, and 2006, indicated average readings of 8.18 for pH, 8.94 ppm for chlorides, and 22.63 ppm for sulfates. Also, a 2004 analysis of water samples taken from the two deep potable water wells located on site indicated average readings of 7.5 for pH, 34 ppm for chlorides, and 640 ppm for sulfates. Based on the above results, intake water from Lake Michigan and potable well water are considered non-aggressive to concrete or steel.
No past or present periodic monitoring activities have been performed for drains and sumps to identify chemicals considered aggressive to concrete or steel. However, water collected in floor drains and sumps is monitored for gamma, tritium, and suspended solids. Additionally, if a high sump level is detected in the Reactor Containment Vessel, the sump water may be tested for boron, conductivity, and pH to help determine the leakage source.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 3 of 40 The sources of water that leak from plant systems into floor drains and sumps is either from Lake Michigan, potable wells, or treated water systems. These are all considered non-aggressive to concrete and steel. Consequently, the sumps are not periodically monitored for aggressive constituents. Additionally, identified leaks do not continue for the extensive period of time required for degradation of concrete, steel, and other material to occur.
: 2. The ground water chemistry for inaccessible below grade concrete is periodically monitored in accordance with the Structures Monitoring Program (SMP). However, as stated above, raw water is considered non-aggressive and is therefore not periodically monitored. Furthermore, all structures or structural members within the scope of license renewal that are exposed to a raw water environment are accessible for visual inspection and the applicable aging effects are managed by the SMP, regardless of the composition of the raw water. Therefore, the effects of aging for in-scope structures or structural members exposed to raw water will be adequately managed so that the intended function(s) will be maintained consistent with the CLB for the period of extended operation.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 4 of 40 RAI 3.5.2.3-2


==Background:==
==Background:==
LRATable 3.5.2-1statesthat Structures Monitoring Programwillbeusedforthe aging management ofthesumpsinsidethe Reactor Containment Vessel.Also the applicant assigned industry StandardNoteHwhichimpliesthatthe aging effect is not consistentwiththeGALL Reportforthiscomponent,material, and environment combination.
 
Issue: The environmentisraw waterwhichcanbeaggressive.TheLRAdoes not have information abouttheraw water chemistry.
LRA Table 3.5.2-1 states that Structures Monitoring Program will be used for the aging management of the sumps inside the Reactor Containment Vessel. Also the applicant assigned industry Standard Note H which implies that the aging effect is not consistent with the GALL Report for this component, material, and environment combination.
AccordingtotheGALLReport,IWEisthe applicable programforthe Reactor Containment Vessel structures and components thatformthe containment pressure boundary.However;the applicant has credited Structures MonitoringProgramfortheseitems.Furthermore,theLRATableitemsstate corrosion as the aging effect of embedded steel and intendedfunctiontobe SS (structural support).Request: 1.Explainthe past and present raw water monitoring activities anddiscusstheresultsinterms of the aggressiveness ofrawwater.2.Incaseraw water is aggressive, what inspection/monitoringcriteriaareorwillbe implementedinthe Structures MonitoringProgramto ensurethatthe effects of agingwillbe adequately managed sothatthe intendedfunction(s)for concrete and embedded steelwillbe maintained consistentwiththeCLBforthe period of extended operation.3.Explainthe justification for not including the containmentsumpintheIWEProgram.Notethatinthe AMRlineitislisted as PB (pressure boundary)and SS (structural support).DEK Response1.The informationrequestedbythisRAIisprovidedintheresponsetoRAI3.5.2.3-1,Request1,includedinthis attachment.2.As discussedintheresponsetoRAI3.5.2.3-1,Request1,raw water at Kewaunee is considered non-aggressive.Allin-scope structures or structural members exposedtoarawwater environment are accessibleforvisual inspectionandthe applicableagingeffectsaremanagedwiththe Structures Monitoring Program, regardlessofthe compositionoftherawwater.
Issue:
Therefore,theintendedfunction(s)forconcreteand embeddedsteelwillbe maintained consistentwiththeCLBfortheperiodofextendedoperation.
The environment is raw water which can be aggressive. The LRA does not have information about the raw water chemistry. According to the GALL Report, IWE is the applicable program for the Reactor Containment Vessel structures and components that form the containment pressure boundary.             However; the applicant has credited Structures Monitoring Program for these items. Furthermore, the LRA Table items state corrosion as the aging effect of embedded steel and intended function to be SS (structural support).
SerialNo.09-680DocketNo.50-305 Attachment1/Page5of40 3.ConsistentwithNUREG1801,SectionII,theIWEprogramisapplicabletothe Reactor ContainmentVesselandits componentssuchaspenetrations,airlocks,andhatches,etc.The StructuresMonitoringProgramisusedtomonitoralltheinternalstructuresoftheReactor ContainmentVesselincludingthesumpsandcommonbasemat.ThepressureboundaryfunctionindicatedinLRATables2.4.1-1and3.5.2-1forthe Containmentsumpis consideredasystemfunction(waterretention)andnotastructuralfunction.Specifically,thesumpisnotconsideredpartofthe Reactor ContainmentVesselpressureboundary.
Request:
SerialNo.09-680DocketNo.50-305 Attachment1/Page6of40 RAI 3.5.2.3-3  
: 1. Explain the past and present raw water monitoring activities and discuss the results in terms of the aggressiveness of raw water.
: 2. In case raw water is aggressive, what inspection/monitoring criteria are or will be implemented in the Structures Monitoring Program to ensure that the effects of aging will be adequately managed so that the intended function(s) for concrete and embedded steel will be maintained consistent with the CLB for the period of extended operation.
: 3. Explain the justification for not including the containment sump in the IWE Program.
Note that in the AMR line it is listed as PB (pressure boundary) and SS (structural support).
DEK Response
: 1. The information requested by this RAI is provided in the response to RAI 3.5.2.3-1, Request 1, included in this attachment.
: 2. As discussed in the response to RAI 3.5.2.3-1, Request 1, raw water at Kewaunee is considered non-aggressive. All in-scope structures or structural members exposed to a raw water environment are accessible for visual inspection and the applicable aging effects are managed with the Structures Monitoring Program, regardless of the composition of the raw water. Therefore, the intended function(s) for concrete and embedded steel will be maintained consistent with the CLB for the period of extended operation.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 5 of 40
: 3. Consistent with NUREG 1801, Section II, the IWE program is applicable to the Reactor Containment Vessel and its components such as penetrations, airlocks, and hatches, etc. The Structures Monitoring Program is used to monitor all the internal structures of the Reactor Containment Vessel including the sumps and common basemat. The pressure boundary function indicated in LRA Tables 2.4.1-1 and 3.5.2-1 for the Containment sump is considered a system function (water retention) and not a structural function. Specifically, the sump is not considered part of the Reactor Containment Vessel pressure boundary.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 6 of 40 RAI 3.5.2.3-3


==Background:==
==Background:==


StandardNoteHhasbeen assigned to severallineitemsinLRATables 3.5.2-2 to 3.5.2-14.Standard Note Hindicatesthatthe"aging effect notinNUREG-1801forthis component, material and environment combination." AccordingtotheLRATables,increasein porosity and permeability,lossof strength/leaching of calcium hydroxide ofconcreteare notedinthe environmentair-outdoor.In normal conditions, leaching can occurwhenwater passesthroughtheconcrete.
Standard Note H has been assigned to several line items in LRA Tables 3.5.2-2 to 3.5.2-14. Standard Note H indicates that the "aging effect not in NUREG-1801 for this component, material and environment combination." According to the LRA Tables, increase in porosity and permeability, loss of strength/leaching of calcium hydroxide of concrete are noted in the environment air-outdoor. In normal conditions, leaching can occur when water passes through the concrete.
Issue: The phenomenon of leaching of concrete in air-outdoorisnot clearly describedinthe LRA.Request:Pleasedescribethe structureswhereleaching of calcium hydroxide is occurringinthe environment ofair.Alsoexplainthe possiblereason(s)forsuchleaching.
Issue:
DEK ResponseThe2007 MaintenanceRuleInspectionresultsindicatedminorleachingofconcretein an air-outdoor environmentforthefollowingstructuralmembers:*Themainauxiliary transformernorthandsouthconcretebaywalls*Theconcrete masonrywallthatformsthebackbaywallofthereserveauxiliary transformerandTurbineBuilding exterior wall*TheShieldBuilding exteriorconcretewall*TheScreenhouseforebayexteriorconcretewallInan air-outdoorenvironment,waterfromrainormeltingsnowthat contains small concentrationsofcalciumionscandissolvethecalcium compoundsfoundinconcretewhenitpassesthroughcracksor inadequately prepared construction joints.Efflorescence,asurface phenomenonconsistingofsaltdepositsthathavebeenleachedfromconcrete,canalsooccurinan air-outdoor environment.
The phenomenon of leaching of concrete in air-outdoor is not clearly described in the LRA.
Although efflorescenceisanaestheticissueratherthanastructuralproblem,itdoesindicatethatleachingisoccurring.NUREG-1801indicatesthatleachingofcalciumhydroxideoccursonlyinaflowingwaterenvironment.Leachingdoesoccurmorereadilywhen structures are subjected toflowingwater,ponding,or hydraulicpressure,whichcanoccurwithwatercontrolstructuressuchastheIntake,Screenhouse,andDischargestructures.Therefore,sinceDEKhas conservativelyincludedleachingofcalciumhydroxideasanaging effect/mechanisminan air-outdoorenvironment,StandardNoteHwasappliedto SerialNo.09-680DocketNo.50-305 Attachment 1/Page7of40 indicatethatthisagingeffectisnotinNUREG-1801forthis component, material and environment combination.
Request:
SerialNo.09-680DocketNo.50-305 Attachment1/Page8of40 RAI82.1.27-1 Background/Issue:LRASectionB2.1.27,"ReactorVessel Surveillance," states under Enhancement 1: 'The Reactor Vessel Surveillance programwillbe enhancedtoincludethe applicablelimitationson operating conditionstowhichthe surveillancecapsuleswere exposed(e.g.,neutronflux,spectrum,irradiationtemperature, etc.)." Request: Please providedetailsregardingthese applicablelimitations.Further, demonstrate thatwiththis Enhancement the Reactor Vessel Surveillance programmeetthe acceptance criteria 2,3, and 6thatwere listedinGALL Aging ManagementProgram(AMP)XI.M31,"ReactorVessel Surveillance." DEK Response Enhancement1totheReactorVessel Surveillanceprogram,describedinLRASection 82.1.27,providesaprogram enhancementtoensurethatfuturechangesinplantoperatingparametersorneutronfluxduetopowerupratesorotherconditionsareevaluatedtoensurethatthe parametervaluesusedtoprojecttheeffectsof embrittlementtotheendoftheperiodofextendedoperationremainboundingforactualplantconditions.ThisReactorVesselSurveillanceprogram enhancementwillensurethat:*Changesinplant parameters(e.g.,operating temperature,neutronfluence)towhichreactorvesselmaterialsareexposed,areevaluatedfortheaffectonthe applicabilityofNRCRegulatoryGuide1.99,Revision2, Radiation Embrittlement of ReactorVesselMaterials,RegulatoryPosition1,asdiscussedin1801,SectionXI.M31,Item2.*Plantparameters(e.g.,coldleg temperature,neutronfluence)remainwithintheboundsdefinedforthe surveillancedatausedasinputtothe embrittlementevaluations,asdiscussedinNUREG-1801,SectionXI.M31,Item3.*Reactorvesselexposure conditions(e.g.,neutronflux,spectrum,irradiation temperature,etc.)aremonitoredtoensurethattheactualexposure conditions remain consistentwiththoseusedtoprojecttheeffectsof embrittlementtotheendoftheperiodofextendedoperation,asdiscussedinNUREG-1801,SectionXI.M31,Item6.
Please describe the structures where leaching of calcium hydroxide is occurring in the environment of air. Also explain the possible reason(s) for such leaching.
SerialNo.09-680DocketNo.50-305 Attachment1/Page9of40RAI4.2.2 Reactor Vessel Background/Issue:TheU.S.Nuclear Regulatory Commission's (NRC)reactor vessel integrity database(RVIO)doesnotcontain informationforthe extendedbeltlinematerials reportedinthe LRA.Request:Pleasediscussthe proceduresusedtodeterminethe chemistrydata,initialreference temperature (RTNDT), and marginsforthe extended beltline materials to demonstratethatthereare consistent approachesforbothbeltlineand extendedbeltlinematerials.
DEK Response The 2007 Maintenance Rule Inspection results indicated minor leaching of concrete in an air-outdoor environment for the following structural members:
DEK ResponseChemistrydata,initialreference temperature (RT NOT),andmarginsfortheextendedbeltlinematerialsareprovidedinLRATable4.2-3, RTpTsResultsfor Kewaunee PowerStationBeltline and ExtendedBeltlineRegionMaterialsatEOLR (52.1 EFPY).Theseextendedbeltlinematerial parametersweredeterminedasdescribedbelow.
* The main auxiliary transformer north and south concrete bay walls
Chemistry DataIndeterminingthecopper(Cu)andnickel(Ni)weightpercentages,theoriginalCertificationMaterialTestReports(CMTRs)werereviewedto determinethemeasuredvalues.Insomecases,theCMTRmaynothaveincludedameasuredCuorNiweightpercent.Inthosecases,the best-estimatevaluewas determinedbasedonthefollowingguidanceprovidedinRegulatoryGuide1.99,Revision2, Radiation Embrittlement of ReactorVesselMaterials: "If the best-estimate weight percent Cu andNivaluesarenotavailable,the upperlimitingvaluesgiveninthe materials specificationstowhichthevesselwas built maybeused.Ifnotavailable, conservative estimates(meanplusone standard deviation) based on generic data maybeusedif justificationisprovided.
* The concrete masonry wall that forms the back bay wall of the reserve auxiliary transformer and Turbine Building exterior wall
Ifthereisnoinformationavailable,0.35
* The Shield Building exterior concrete wall
%copper and 1.0%nickel should be assumed."BetweentheCMTRsandthe guidancefromRegulatoryGuide1.99,Revision2providedabove, best-estimateCuandNiweight percentages were determinedfortheextendedbeltlinematerials.InitialReference TemperatureThedeterminationoffracture toughnessoftheferriticmaterialsusedforreactorvesselsisnecessarytoensurethatsuch componentswillbehaveinanon-brittle manner andthattheprobabilityofarapidly propagatingfracturewillbeminimizedunderoperating,maintenance,andtesting conditionsandduring anticipatedoperationaloccurrences.Inmostcases,thefracture toughnessischaracterizedbyitsreferencenilductility temperature (RT NOT).
* The Screenhouse forebay exterior concrete wall In an air-outdoor environment, water from rain or melting snow that contains small concentrations of calcium ions can dissolve the calcium compounds found in concrete when it passes through cracks or inadequately prepared construction joints.
SerialNo.09-680DocketNo.50-305 Attachment1/Page10of40Thefracture toughnesspropertiesoftheferriticmaterialinthereactorvesselpressureboundarywere determined,asrequiredby10CFR50, AppendixG,in accordance withtherequirementsinsubsectionNB-2331ofSectionIIIoftheASMEBoilerandPressureVesselCode.TheinitialRT NOTvalueswere determined from drop-weighttestsorCharpytestresultsin accordancewithBranchTechnicalPositionMTEB5-2("Fracture ToughnessRequirements")oftheNRCStandardReviewPlan (NUREG-0800), Section5.3.2,Rev.1(1981),as summarized below:*T NOTshallbedeterminedbymeansof drop-weight test.*T NOTistheRT NOTifatT NOT+60&deg;F,aCharpytestexhibits50ft-lbsofenergyand35milslateralexpansion.*Ifnot,thenthe temperaturewhenthisoccursmustbe determinedusingtheminimumdatapointsfromalltheCharpytestsonthatmaterial.This temperatureshallbeknownasT 50/35andRT NOTshallbeT50/35-60&deg;F.ThisassumestheCharpytestswereintheweak (transverse/axial) orientation.*IftheCharpytestsareinthestrong (longitudinal/tangential)orientation,then T 50/35isequaltoT 50/35(Long)
Efflorescence, a surface phenomenon consisting of salt deposits that have been leached from concrete, can also occur in an air-outdoor environment. Although efflorescence is an aesthetic issue rather than a structural problem, it does indicate that leaching is occurring.
+20&deg;F.*RT NOTisthehigherofT NOTversus(T50/35-60&deg;F).FortheE8018weldmaterial,whererequiredmaterialstestdatawerenotavailablefromtheCMTR,genericvaluesofRT NOTweredeterminedtobe10&deg;Fin accordance withNUREG-0800,Section5.3.2,position 1.1 (4).MarginMarginisaddedtoaccountfor uncertaintiesinthevaluesofRT NOT(U), copperandnickelcontents,fluence,and calculationalprocedures.Margin,M,wasevaluatedfromthe equation: M=2*(aJ+at:.2)1/2auisthestandarddeviationforRT NOT(U)au=OaFwhenRT NOT(U)isameasuredvalue au=17&deg;FwhenRT NOT(U)isagenericvalueformostbasemetalsandwelds(orasjustifiedbyspecificmaterialstatisticalanalyses) at:.isthestandarddeviationforRT NOTForplatesandforgings:
NUREG-1801 indicates that leaching of calcium hydroxide occurs only in a flowing water environment. Leaching does occur more readily when structures are subjected to flowing water, ponding, or hydraulic pressure, which can occur with water control structures such as the Intake, Screenhouse, and Discharge structures. Therefore, since DEK has conservatively included leaching of calcium hydroxide as an aging effect/mechanism in an air-outdoor environment, Standard Note H was applied to
at:.=1 JOF when surveillancecapsuledataarenotused at:.=8.5&deg;FwhensurveillancecapsuledataareusedForwelds: at:.=28&deg;Fwhen surveillancecapsuledataarenotused at:.=14&deg;Fwhensurveillancecapsuledataareused SerialNo.09-680DocketNo.50-305 Attachment1/Page11of40 Or:,.isnottoexceedonehalfof NOT, where NOTisthemeanvalueofthetransition temperatureshift(changeinRT NOT)duetoirradiation.Insummary,the proceduresthatwereappliedto determine the propertiesfortheextendedbeltline materials are consistent with thoseappliedfor determination of propertiesforthe traditionalbeltlineforgings.
 
SerialNo.09-680 Docket No.50-305 Attachment1/Page12of40 RAI3.3.2.2.14-1
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 7 of 40 indicate that this aging effect is not in NUREG -1801 for this component, material and environment combination.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 8 of 40 RAI82.1.27-1 Background/Issue:
LRA Section B2.1.27, "Reactor Vessel Surveillance," states under Enhancement 1: 'The Reactor Vessel Surveillance program will be enhanced to include the applicable limitations on operating conditions to which the surveillance capsules were exposed (e.g., neutron flux, spectrum, irradiation temperature, etc.)."
Request:
Please provide details regarding these applicable limitations. Further, demonstrate that with this Enhancement the Reactor Vessel Surveillance program meet the acceptance criteria 2,3, and 6 that were listed in GALL Aging Management Program (AMP) XI.M31, "Reactor Vessel Surveillance."
DEK Response Enhancement 1 to the Reactor Vessel Surveillance program, described in LRA Section 82.1.27, provides a program enhancement to ensure that future changes in plant operating parameters or neutron flux due to power uprates or other conditions are evaluated to ensure that the parameter values used to project the effects of embrittlement to the end of the period of extended operation remain bounding for actual plant conditions.
This Reactor Vessel Surveillance program enhancement will ensure that:
* Changes in plant parameters (e.g., operating temperature, neutron fluence) to which reactor vessel materials are exposed, are evaluated for the affect on the applicability of NRC Regulatory Guide 1.99, Revision 2, Radiation Embrittlement of Reactor Vessel Materials, Regulatory Position 1, as discussed in NUREG-1801, Section XI.M31 , Item 2.
* Plant parameters (e.g., cold leg temperature, neutron fluence) remain within the bounds defined for the surveillance data used as input to the embrittlement evaluations, as discussed in NUREG-1801, Section XI.M31 , Item 3.
* Reactor vessel exposure conditions (e.g., neutron flux, spectrum, irradiation temperature, etc.) are monitored to ensure that the actual exposure conditions remain consistent with those used to project the effects of embrittlement to the end of the period of extended operation, as discussed in NUREG-1801 , Section XI.M31 , Item 6.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 9 of 40 RAI 4.2.2 Reactor Vessel Background/Issue:
The U.S. Nuclear Regulatory Commission's (NRC) reactor vessel integrity database (RVIO) does not contain information for the extended beltline materials reported in the LRA.
Request:
Please discuss the procedures used to determine the chemistry data, initial reference temperature (RTNDT), and margins for the extended beltline materials to demonstrate that there are consistent approaches for both beltline and extended beltline materials.
DEK Response Chemistry data, initial reference temperature (RT NOT), and margins for the extended beltline materials are provided in LRA Table 4.2-3, RTp Ts Results for Kewaunee Power Station Beltline and Extended Beltline Region Materials at EOLR (52. 1 EFPY). These extended beltline material parameters were determined as described below.
Chemistry Data In determining the copper (Cu) and nickel (Ni) weight percentages, the original Certification Material Test Reports (CMTRs) were reviewed to determine the measured values. In some cases, the CMTR may not have included a measured Cu or Ni weight percent. In those cases, the best-estimate value was determined based on the following guidance provided in Regulatory Guide 1.99, Revision 2, Radiation Embrittlement of Reactor Vessel Materials:
      "If the best-estimate weight percent Cu and Ni values are not available, the upper limiting values given in the materials specifications to which the vessel was built may be used.     If not available, conservative estimates (mean plus one standard deviation) based on generic data may be used if justification is provided. If there is no information available, 0.35 % copper and 1.0% nickel should be assumed."
Between the CMTRs and the guidance from Regulatory Guide 1.99, Revision 2 provided above, best-estimate Cu and Ni weight percentages were determined for the extended beltline materials.
Initial Reference Temperature The determination of fracture toughness of the ferritic materials used for reactor vessels is necessary to ensure that such components will behave in a non-brittle manner and that the probability of a rapidly propagating fracture will be minimized under operating, maintenance, and testing conditions and during anticipated operational occurrences. In most cases, the fracture toughness is characterized by its reference nil ductility temperature (RT NOT).
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 10 of 40 The fracture toughness properties of the ferritic material in the reactor vessel pressure boundary were determined, as required by 10 CFR 50, Appendix G, in accordance with the requirements in subsection NB-2331 of Section III of the ASME Boiler and Pressure Vessel Code. The initial RTNOT values were determined from drop-weight tests or Charpy test results in accordance with Branch Technical Position MTEB 5-2 ("Fracture Toughness Requirements") of the NRC Standard Review Plan (NUREG-0800), Section 5.3.2, Rev. 1 (1981), as summarized below:
* T NOT shall be determined by means of drop-weight test.
* T NOT is the RTNOT if at T NOT + 60&deg;F, a Charpy test exhibits 50 ft-lbs of energy and 35 mils lateral expansion.
* If not, then the temperature when this occurs must be determined using the minimum data points from all the Charpy tests on that material. This temperature shall be known as T 50/35 and RTNOT shall be T50/35 - 60&deg;F. This assumes the Charpy tests were in the weak (transverse/axial) orientation.
* If the Charpy tests are in the strong (longitudinal/tangential) orientation, then T50/35 is equal to T50/35(Long) + 20&deg;F.
* RTNOT is the higher of T NOT versus (T50/35 - 60&deg;F).
For the E8018 weld material, where required materials test data were not available from the CMTR, generic values of RTNOT were determined to be 10&deg;F in accordance with NUREG-0800, Section 5.3.2, position 1.1 (4).
Margin Margin is added to account for uncertainties in the values of RTNOT(U), copper and nickel contents, fluence, and calculational procedures. Margin, M, was evaluated from the equation: M = 2 * (aJ + at:.2 ) 1/2 au is the standard deviation for RTNOT(U) au   = OaF when RTNOT(U) is a measured value au =   17&deg;F when RTNOT(U) is a generic value for most base metals and welds (or as justified by specific material statistical analyses) at:. is the standard deviation for RTNOT For plates and forgings:
at:. = 1JOF when surveillance capsule data are not used at:. = 8.5&deg;F when surveillance capsule data are used For welds:
at:. = 28&deg;F when surveillance capsule data are not used at:. = 14&deg;F when surveillance capsule data are used
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 11 of 40 Or:,. is not to exceed one half of ~RT NOT, where ~RT NOT is the mean value of the transition temperature shift (change in RTNOT) due to irradiation.
In summary, the procedures that were applied to determine the properties for the extended beltline materials are consistent with those applied for determination of properties for the traditional beltline forgings.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 12 of 40 RAI3.3.2.2.14-1


==Background:==
==Background:==


LRA and Standard ReviewPlan(SRP)Sections 3.3.2.2.14refertoLRA and SRP Tables 3.3.1-35.Thesetables addresstheloss of materialduetoa claddingbreachon stainless steelcladpumpcasings exposedtotreated boratedwater.Thesetables recommend"further evaluation"onthe part ofthestaff.TheGALL Report recommends managingthisaging processthroughtheuse of plant-specific aging managementprogram.The applicantstatesthatits chargingpumpsare neither centrifugal nor constructed from steelcladwith stainless steel andthatthisitemis,therefore,not applicable.
LRA and Standard Review Plan (SRP) Sections 3.3.2.2.14 refer to LRA and SRP Tables 3.3.1- 35. These tables address the loss of material due to a cladding breach on stainless steel clad pump casings exposed to treated borated water. These tables recommend "further evaluation" on the part of the staff. The GALL Report recommends managing this aging process through the use of plant-specific aging management program. The applicant states that its charging pumps are neither centrifugal nor constructed from steel clad with stainless steel and that this item is, therefore, not applicable.
Issue:Initsreview ofLRATable 3.3.1-35, the staff notedthatitisquitecommonfor plants to have interchangeablepumpsfor safety injection and normalcharging.The staff alsonotedthatitisquitecommonforsome of these pumpstobe centrifugal andsometobe positivedisplacement.The staff further notedthatLRASection 3.2.2.2.6impliesthat the safetyinjectionpumpsarecentrifugal.
Issue:
Lastly the staff notedthatif any of thesepumpsare stainless steelclad,thisitem shouldbeconsidered.
In its review of LRA Table 3.3.1-35, the staff noted that it is quite common for plants to have interchangeable pumps for safety injection and normal charging. The staff also noted that it is quite common for some of these pumps to be centrifugal and some to be positive displacement. The staff further noted that LRA Section 3.2.2.2.6 implies that the safety injection pumps are centrifugal. Lastly the staff noted that if any of these pumps are stainless steel clad, this item should be considered.
Request:Pleaseconfirm whether the safetyinjectionpumpsare stainless steel clad and whetheranyofthesepumpsarecentrifugal.
Request:
If these pumps are centrifugal and stainless steel clad, pleaseconfirmtheissue of loss of materialdueto claddingbreachisbeing managedorthatitisnot applicabletothesepumps.
Please confirm whether the safety injection pumps are stainless steel clad and whether any of these pumps are centrifugal. If these pumps are centrifugal and stainless steel clad, please confirm the issue of loss of material due to cladding breach is being managed or that it is not applicable to these pumps.
DEK Response The Kewaunee safetyinjectionpumpsare stainlesssteelcladcarbonsteel centrifugal pumps manufactured by Sulzer-Bingham.BasedonNRC InformationNotice80-38,"Cracking in ChargingPumpCasing Cladding," and other industry operating experience,lossofmaterialduetoa stainless steel claddingbreachis associatedwiththe manufacturing process of pumps suppliedbythePacificPumpDivisionof Dresser Industries.Basedonasearchof industry databases,thereisno operating experiencerelatedtolossof materialduetoa claddingbreachfor centrifugal pumps manufactured by Sulzer-Bingham.
DEK Response The Kewaunee safety injection pumps are stainless steel clad carbon steel centrifugal pumps manufactured by Sulzer-Bingham.
Therefore,lossofmaterialduetocladdingbreachwas determinednottobe applicabletothe Kewaunee safety injection pumps.The Kewaunee chargingpumpsand safety injectionpumpsarenot interchangeable.
Based on NRC Information Notice 80-38, "Cracking in Charging Pump Casing Cladding," and other industry operating experience, loss of material due to a stainless steel cladding breach is associated with the manufacturing process of pumps supplied by the Pacific Pump Division of Dresser Industries. Based on a search of industry databases, there is no operating experience related to loss of material due to a cladding breach for centrifugal pumps manufactured by Sulzer-Bingham. Therefore, loss of material due to cladding breach was determined not to be applicable to the Kewaunee safety injection pumps.
SerialNo.09-680DocketNo.50-305 Attachment1/Page13of40 RAI3.4.2.2.3-1
The Kewaunee charging pumps and safety injection pumps are not interchangeable.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 13 of 40 RAI3.4.2.2.3-1


==Background:==
==Background:==
LRAand Standard ReviewPlanforReview of License Renewal Application for Nuclear PowerPlants(SRP-LR)
 
Sections 3.4.2.2.3refertoLRA and SRP-LR Tables3.4.1-8.Thesetablesaddresstheloss of materialduetogeneral,pitting,crevice and microbiology-influenced corrosion (MIG)as well asfoulingon steel piping, piping components and piping elements exposedtorawwater.Thesetables recommend"further evaluation"onthe part ofthestaff.TheGALL Report recommends managingthisaging processthroughtheuse of a plant-specificAMP.The applicantstatesthat components includedinthedefinition ofthistableare isolatedfromraw water and thattheywerenot evaluatedforagingeffects.
LRA and Standard Review Plan for Review of License Renewal Application for Nuclear Power Plants (SRP-LR) Sections 3.4.2.2.3 refer to LRA and SRP-LR Tables 3.4. 1-8.
Issue:Initsreview ofLRATable3.4.1-8, the staff notedthatthe applicant statedthatthe auxiliaryfeedpumpsuction pipingwasnot evaluatedforaging.The staffalsonotedthatthe applicant describes a motor operatedvalvewhichisusedtoisolatethe auxiliary feedwatersystemfromtheservicewatersystem(rawwater).The staff further notedthatthe content of the piping downstream oftheisolationvalvesisnotdisclosed.
These tables address the loss of material due to general, pitting, crevice and microbiology-influenced corrosion (MIG) as well as fouling on steel piping, piping components and piping elements exposed to raw water. These tables recommend "further evaluation" on the part of the staff. The GALL Report recommends managing this aging process through the use of a plant-specific AMP. The applicant states that components included in the definition of this table are isolated from raw water and that they were not evaluated for aging effects.
Basedontheabove,the staff believesthatitis necessary to evaluatetheentire auxiliary feedwatersystemforaging.The staffhasno theoretical objectionstoincludingthe evaluation of portions ofthesystem as part of other AMRreviewitems as long as the AMP cited is appropriate and as long as the applicantfullydescribes, as part of thisAMRitem,theitem underwhicheach component ofthesystemwillbeevaluated.
Issue:
Reguest:Pleaseconfirmthattheentire auxiliary feedwatersystemwillbe evaluatedforaging and to modify this AMR item and otherAMRitems as appropriate to allow the staff toconfirmthateach portion of the auxiliary feedwatersystemis being evaluated throughtheuse of appropriate AMP andAMRitems.DEK ResponseThenormalsupplyofwatertotheAuxiliary FeedwaterSystemisthe condensatestoragetanks.Theback-upsupplyofwatertotheAuxiliary FeedwaterSystemisfromtheService WaterSystem.LRASection3.4.2.2.3andlicenserenewaldrawing202-2(atlocationsE-9throughE-12)identifythattheback-upsourceofwaterisisolatedfromtheAuxiliary FeedwaterSystembynormallyclosed motor-operated valves(SW502,SW601A,andSW601B).Therefore,theAuxiliary FeedwaterSystemwasnotevaluatedforagingeffectsduetoexposuretotheService WaterSystem(rawwater)environment.However,theentireAuxiliary FeedwaterSystem(includingtheauxiliary feedwaterpumpsuctionpiping downstreamofthe normally closed motor-operatedvalves)was evaluatedforagingeffectsduetoexposuretothe condensatestoragetank SerialNo.09-680 Docket No.50-305 Attachment 1/Page14of40 water supply (treated water-secondary) environment, as indicatedforthe componenttype"Pipe"inLRATable3.4.2-7.
In its review of LRA Table 3.4. 1-8, the staff noted that the applicant stated that the auxiliary feed pump suction piping was not evaluated for aging. The staff also noted that the applicant describes a motor operated valve which is used to isolate the auxiliary feedwater system from the service water system (raw water). The staff further noted that the content of the piping downstream of the isolation valves is not disclosed. Based on the above, the staff believes that it is necessary to evaluate the entire auxiliary feedwater system for aging. The staff has no theoretical objections to including the evaluation of portions of the system as part of other AMR review items as long as the AMP cited is appropriate and as long as the applicant fully describes, as part of this AMR item, the item under which each component of the system will be evaluated.
SerialNo.09-680DocketNo.50-305 Attachment1/Page15of40 RAI3.2.2.5.1.-1
Reguest:
Please confirm that the entire auxiliary feedwater system will be evaluated for aging and to modify this AMR item and other AMR items as appropriate to allow the staff to confirm that each portion of the auxiliary feedwater system is being evaluated through the use of appropriate AMP and AMR items.
DEK Response The normal supply of water to the Auxiliary Feedwater System is the condensate storage tanks. The back-up supply of water to the Auxiliary Feedwater System is from the Service Water System. LRA Section 3.4.2.2.3 and license renewal drawing LRM-202-2 (at locations E-9 through E-12) identify that the back-up source of water is isolated from the Auxiliary Feedwater System by normally closed motor-operated valves (SW502, SW601A, and SW601B). Therefore, the Auxiliary Feedwater System was not evaluated for aging effects due to exposure to the Service Water System (raw water) environment. However, the entire Auxiliary Feedwater System (including the auxiliary feedwater pump suction piping downstream of the normally closed motor-operated valves) was evaluated for aging effects due to exposure to the condensate storage tank
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 14 of 40 water supply (treated water - secondary) environment, as indicated for the component type "Pipe" in LRA Table 3.4.2-7.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 15 of 40 RAI3.2.2.5.1.-1


==Background:==
==Background:==


LRA andSRP-LRSections 3.3.2.2.5.
LRA and SRP-LR Sections 3.3.2.2.5. 1 refer to LRA and SRP-LR Tables 3.3. 1-11.
1refertoLRA andSRP-LRTables3.3.1-11.Thesetablesaddress hardening and loss ofstrengthduetodegradationof elastomers exposed to uncontrolled indoorair.Thesetables recommend"further evaluation"onthe part ofthestaff.The applicant proposestomanagethis aging processthroughtheuse of its AMP"External Surfaces Monitoring"(LRAB2.1.10).TheGALL Reportrecommendsthatthisaging process be managedthroughtheuse of a plant-specificAMP.The applicant proposesthatthe AMR items associatedwithTable3.3.1-11 are consistentwiththeGALL Reportintermsofmaterial,environment, and aging effect but a different AMP is credited(GenericNoteE).
These tables address hardening and loss of strength due to degradation of elastomers exposed to uncontrolled indoor air. These tables recommend "further evaluation" on the part of the staff. The applicant proposes to manage this aging process through the use of its AMP "External Surfaces Monitoring" (LRA B2.1.10).             The GALL Report recommends that this aging process be managed through the use of a plant-specific AMP. The applicant proposes that the AMR items associated with Table 3.3. 1-11 are consistent with the GALL Report in terms of material, environment, and aging effect but a different AMP is credited (Generic Note E).
Issue:Initsreview ofLRATable 3.3.1-11, the staffnotedthatthe"ExternalSurfaces Monitoring" AMP proposestomanagetheaging of elastomeric materialsthroughthe use ofvisualinspections.The staff also notedthattheagingeffectsbeing considered are hardening and loss ofstrength.Giventhatchangesin material properties of elastomericmaterialsarenot always accompanied by achangeinappearance,the staffisunaware of how a visual inspection will detecttheagingeffects under consideration.
Issue:
The staff further notedthatTable3.3.1-11includesboth internal and external surfaces ofelastomers.Finally,the staff noted that a search of Table 2itemsintheLRA associatedwithTable3.3.1-11 reveals only items associated with external surfaces.Giventhenature of the componentslisted,it appearsthatmost,ifnotall, oftheseitems shouldhavean additional item associatedwiththeir internalsurface.The staff questions the apparent lack oftheseTable 2 items.Request: Please clarify how avisualinspectionwilldetectchangesin hardness and strength of elastomericmaterialsorto propose an alternate AMP which includes manual manipulation of the elastomeric material andtoexplainthe apparent lack of AMR itemsinTable 3.3.1-11 associated with internal surfaces.DEK ResponseAvisualinspectionisnotreliedonalonetodetectchangesinhardnessandstrengthof elastomericmaterials.TheExternalSurfacesMonitoringprogramwillrequire performanceofvisual inspectionsandphysical manipulationbyplantpersonnelqualifiedtodetecthardeningandlossofstrengthofelastomericmaterialsasdescribedintheresponsetoRAI82.1.10-1inDEKletterdatedAugust17,2009(DEKSerialNo.09-469)[ADAMSAccessionNo.
In its review of LRA Table 3.3.1-11, the staff noted that the "External Surfaces Monitoring" AMP proposes to manage the aging of elastomeric materials through the use of visual inspections. The staff also noted that the aging effects being considered are hardening and loss of strength. Given that changes in material properties of elastomeric materials are not always accompanied by a change in appearance, the staff is unaware of how a visual inspection will detect the aging effects under consideration.
ML092320093].
The staff further noted that Table 3.3. 1-11 includes both internal and external surfaces of elastomers. Finally, the staff noted that a search of Table 2 items in the LRA associated with Table 3.3. 1-11 reveals only items associated with external surfaces.
SerialNo.09-680DocketNo.50-305 Attachment1/Page16of40AsindicatedinLRATables3.3.2-10through3.3.2-17,"air-moist"and"air-indoorcontrolled"aretheinternal environments for elastomericmaterials.Hardeningandloss of strength/elastomers degradationwasidentifiedasanagingeffectrequiring management for elastomericmaterialsexposedtotheseinternal environments.
Given the nature of the components listed, it appears that most, if not all, of these items should have an additional item associated with their internal surface.           The staff questions the apparent lack of these Table 2 items.
TheInternalSurfacesMonitoringprogramwithintheWorkControlProcessprogram(describedinDEKletterdated September25,2009[ADAMSAccessionNo.
Request:
ML092720184])willmanagetheagingof elastomericmaterialinternalsurfacesandincludesphysicalmanipulationinadditiontovisualinspection.
Please clarify how a visual inspection will detect changes in hardness and strength of elastomeric materials or to propose an alternate AMP which includes manual manipulation of the elastomeric material and to explain the apparent lack of AMR items in Table 3.3.1-11 associated with internal surfaces.
SerialNo.09-680DocketNo.50-305 Attachment1/Page17of40 RAI3.3.2.3-1
DEK Response A visual inspection is not relied on alone to detect changes in hardness and strength of elastomeric materials.     The External Surfaces Monitoring program will require performance of visual inspections and physical manipulation by plant personnel qualified to detect hardening and loss of strength of elastomeric materials as described in the response to RAI 82.1.10-1 in DEK letter dated August 17, 2009 (DEK Serial No.
09-469) [ADAMS Accession No. ML092320093].
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 16 of 40 As indicated in LRA Tables 3.3.2-10 through 3.3.2-17, "air-moist" and "air-indoor controlled" are the internal environments for elastomeric materials. Hardening and loss of strength/elastomers degradation was identified as an aging effect requiring management for elastomeric materials exposed to these internal environments. The Internal Surfaces Monitoring program within the Work Control Process program (described in DEK letter dated September 25, 2009 [ADAMS Accession No.
ML092720184]) will manage the aging of elastomeric material internal surfaces and includes physical manipulation in addition to visual inspection.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 17 of 40 RAI3.3.2.3-1


==Background:==
==Background:==
LRATables 3.3.2-8 and 3.3.2-27containitemswhich address the interior surfaces of elastomeric materials exposedtoinertgas.The applicant proposesthatthereisno aging effect associatedwiththis combination of material and environment andthatno AMPisrequired.The applicant proposesthatforthecomponent, material and environment combinationlistedtheaging effect being consideredisnot includedinthe GALL Report(GenericNoteH).
 
Issue:Initsreview oftheseitems,the staff noted that mechanisms otherthanthenature of thegasin contactwiththe interior surfaces of elastomericmaterials(e.g.,temperature and vibration) couldcauseaging ofthosematerials.
LRA Tables 3.3.2-8 and 3.3.2-27 contain items which address the interior surfaces of elastomeric materials exposed to inert gas. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no AMP is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).
Basedonthe numerouscausesfor aging of elastomericmaterials,the staff cannot concludefromtheinformation providedthatthe components under considerationwillnotundergoaging.
Issue:
Request:Pleaseincludethese componentsinan appropriate AMP or provide sufficientinformationto allow the stafftoconcludethat, under the circumstances beingconsidered,no agingwilloccur.
In its review of these items, the staff noted that mechanisms other than the nature of the gas in contact with the interior surfaces of elastomeric materials (e.g., temperature and vibration) could cause aging of those materials. Based on the numerous causes for aging of elastomeric materials, the staff cannot conclude from the information provided that the components under consideration will not undergo aging.
DEK Response The elastomers(hoses)shownin LRA Tables 3.3.2-8 and 3.3.2-27areexposedtoa gas-inert (nitrogen) environment internallyandan air-indoor uncontrolled environmentontheexternalsurface.
Request:
LRA Tables 3.3.2-8 and 3.3.2-27identifythatnoagingeffects were determinedtobe applicabletotheinternalsurfaceofthehosesbasedon exposuretoaninertgas.However,agingeffectsare applicabletotheexternalsurfaceofthehoses.Crackingand changeinmaterial propertiesduetothermal exposure were determinedtobe applicableagingeffectsfortheexternal surfacesofthese components.Asindicatedinthe LRAtables,theseagingeffectswillbe managed bytheWorkControlProcessprogram.As described in DEKletterdated September 25, 2009[ADAMSAccessionNo.
Please include these components in an appropriate AMP or provide sufficient information to allow the staff to conclude that, under the circumstances being considered, no aging will occur.
ML092720184], Attachment2,page5,physical manipulationandvisual inspection techniqueswillbeusedtodetect cracking andchangeinmaterial properties of elastomeric materials.
DEK Response The elastomers (hoses) shown in LRA Tables 3.3.2-8 and 3.3.2-27 are exposed to a gas-inert (nitrogen) environment internally and an air-indoor uncontrolled environment on the external surface. LRA Tables 3.3.2-8 and 3.3.2-27 identify that no aging effects were determined to be applicable to the internal surface of the hoses based on exposure to an inert gas. However, aging effects are applicable to the external surface of the hoses. Cracking and change in material properties due to thermal exposure were determined to be applicable aging effects for the external surfaces of these components. As indicated in the LRA tables, these aging effects will be managed by the Work Control Process program. As described in DEK letter dated September 25, 2009 [ADAMS Accession No. ML092720184], Attachment 2, page 5, physical manipulation and visual inspection techniques will be used to detect cracking and change in material properties of elastomeric materials.
SerialNo.09-680DocketNo.50-305 Attachment1/Page18of40 RAI 3.3.2.3-2  
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 18 of 40 RAI 3.3.2.3-2


==Background:==
==Background:==
LRATables 3.3.2-10 through 3.3.2-17containitemswhichaddress changes in material properties and cracking of the exterior surfaces of elastomeric materials exposed to uncontrolled indoorair.The applicant proposestomanagethisaging process throughtheuse ofitsAMP,"External Surfaces Monitoring"(LRAB2.1.10).The applicant proposesthatforthecomponent, material and environment combination listedtheagingeffectbeing consideredisnot includedintheGALL Report(GenericNoteH).
 
Issue:Initsreviewoftheseitems,the staff notedthatthe proposed AMPutilizesvisualinspectionto identifyaging.The staff also noted that identification of cracking in elastomers may be difficult using only visual inspectiontechniques.The staff furthernotedthatchangesin material properties such as hardness and elasticity cannot be reliably identified using only visual inspection techniques.
LRA Tables 3.3.2-10 through 3.3.2-17 contain items which address changes in material properties and cracking of the exterior surfaces of elastomeric materials exposed to uncontrolled indoor air. The applicant proposes to manage this aging process through the use of its AMP, "External Surfaces Monitoring" (LRA B2. 1. 10). The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).
Request: Please propose an AMPwhichincludesvisualinspection and manual manipulation of a sufficient numberorarea of elastomeric material at a sufficient inspection frequency to adequately detectcrackingor changesinthe material propertiesofthosematerials.
Issue:
DEK ResponseTheExternalSurfacesMonitoringprogramperformsvisual inspectionsandphysicalmanipulationbyplantpersonnelqualifiedtodetectchangesinmaterial properties andcrackingof elastomericmaterials,asdescribedintheresponsetoRAI82.1.10-1inDEKletterdatedAugust17,2009[ADAMSAccessionNo.
In its review of these items, the staff noted that the proposed AMP utilizes visual inspection to identify aging. The staff also noted that identification of cracking in elastomers may be difficult using only visual inspection techniques. The staff further noted that changes in material properties such as hardness and elasticity cannot be reliably identified using only visual inspection techniques.
ML092320093].Onaroutinebasis,andaspartoftheExternalSurfacesMonitoringprogram,Operations,HealthPhysics,andEngineeringpersonnelconductinspectionsof accessible componentsurfaces,includingelastomericmaterials,innormallyaccessedareas.
Request:
Inspections ofventilationsystem componentsareperformedatleastonceperrefuelingcycle.Thescopeand frequency of inspectionsperformedbytheExternalSurfacesMonitoringprogramaresufficientto adequatelydetectcrackingandchangesinmaterialpropertiesofelastomericmaterialsinthe ventilation systems.
Please propose an AMP which includes visual inspection and manual manipulation of a sufficient number or area of elastomeric material at a sufficient inspection frequency to adequately detect cracking or changes in the material properties of those materials.
SerialNo.09-680 Docket No.50-305 Attachment 1/Page19of40 RAI3.5.2.3.2-1
DEK Response The External Surfaces Monitoring program performs visual inspections and physical manipulation by plant personnel qualified to detect changes in material properties and cracking of elastomeric materials, as described in the response to RAI 82.1.10-1 in DEK letter dated August 17, 2009 [ADAMS Accession No. ML092320093]. On a routine basis, and as part of the External Surfaces Monitoring program, Operations, Health Physics, and Engineering personnel conduct inspections of accessible component surfaces, including elastomeric materials, in normally accessed areas. Inspections of ventilation system components are performed at least once per refueling cycle.
The scope and frequency of inspections performed by the External Surfaces Monitoring program are sufficient to adequately detect cracking and changes in material properties of elastomeric materials in the ventilation systems.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 19 of 40 RAI3.5.2.3.2-1


==Background:==
==Background:==
LRATable 3.5.2-2 containsitemswhichaddresschangesin material properties and cracking of the exterior surfaces of elastomeric materials exposed to uncontrolled indoorair.The applicant proposestomanagethisaging processthroughtheuse ofitsAMP,"External Surfaces Monitoring" (LRA 82.1.10).The applicant proposesthatforthe component, material and environment combinationlistedtheagingeffectbeing consideredisnot includedintheGALLReport(GenericNoteH).
 
Issue:Initsreview oftheseitems,the staff notedthatthe proposed AMPutilizesvisualinspectionto identifyaging.The staff also noted that identification ofcrackingin elastomers may be difficultusingonlyvisual inspectiontechniques.The staff furthernotedthatchangesin material properties such as hardness and elasticity cannot be reliably identified using onlyvisualinspectiontechniques.
LRA Table 3.5.2-2 contains items which address changes in material properties and cracking of the exterior surfaces of elastomeric materials exposed to uncontrolled indoor air. The applicant proposes to manage this aging process through the use of its AMP, "External Surfaces Monitoring" (LRA 82.1.10). The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).
Request: Please propose an AMPwhichincludesvisualinspection and manual manipulation of a sufficient numberorarea of elastomeric material at a sufficient inspection frequency to adequately detect crackingorchangesinthe material properties ofthosematerials.
Issue:
DEK Response The External Surfaces Monitoring program will perform visual inspections and physical manipulationbyplant personnel qualified to detect cracking and changesinthe material properties in elastomers, as describedinthe responsetoRAI 82.1.10-1inDEK letter dated August17,2009(DEKSerialNo.
In its review of these items, the staff noted that the proposed AMP utilizes visual inspection to identify aging. The staff also noted that identification of cracking in elastomers may be difficult using only visual inspection techniques. The staff further noted that changes in material properties such as hardness and elasticity cannot be reliably identified using only visual inspection techniques.
09-469)[ADAMS Accession No.M L092320093].
Request:
Penetration seals (flexible seals, bellowsseals,platesseals) identifiedinLRA Table 3.5.2-2arefire protection features.Theagingof these penetrationsealsare managedbyboththeFire Protection and External Surfaces Monitoring programs.The inspections performedbytheFire Protection program are consistentwiththe recommendations of NUREG-1801, SectionXI.M26,forboththe typeandthe frequency of inspection.Allofthe10CFR50 Appendix R-related penetrationseals,and20%ofthe10CFR50 Appendix A-related penetrationseals,are inspectedduringeachrefuelingoutage.
Please propose an AMP which includes visual inspection and manual manipulation of a sufficient number or area of elastomeric material at a sufficient inspection frequency to adequately detect cracking or changes in the material properties of those materials.
The External Surfaces Monitoring program inspections are performed in conjunctionwiththeFire Protection program inspectionssuchthatthe frequencyofthe inspections are sufficient to detect cracking or changes in material propertiesofthe elastomers.
DEK Response The External Surfaces Monitoring program will perform visual inspections and physical manipulation by plant personnel qualified to detect cracking and changes in the material properties in elastomers, as described in the response to RAI 82.1.10-1 in DEK letter dated August 17, 2009 (DEK Serial No. 09-469) [ADAMS Accession No.
SerialNo.09-680DocketNo.50-305 Attachment1/Page20of40 RAI3.2.2.2.6-1
ML092320093].
Penetration seals (flexible seals, bellows seals, plates seals) identified in LRA Table 3.5.2-2 are fire protection features. The aging of these penetration seals are managed by both the Fire Protection and External Surfaces Monitoring programs.                 The inspections performed by the Fire Protection program are consistent with the recommendations of NUREG-1801, Section XI.M26, for both the type and the frequency of inspection. All of the 10 CFR 50 Appendix R-related penetration seals, and 20% of the 10 CFR 50 Appendix A-related penetration seals, are inspected during each refueling outage.
The External Surfaces Monitoring program inspections are performed in conjunction with the Fire Protection program inspections such that the frequency of the inspections are sufficient to detect cracking or changes in material properties of the elastomers.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 20 of 40 RAI3.2.2.2.6-1


==Background:==
==Background:==


LRA andSRPSections 3.2.2.2.6refertoLRA andSRPTables 3.2.1-12.Thesetablesaddressloss of materialduetoerosion of stainless steel high pressure safety injection (charging) pump miniflow orifice exposedtotreated boratedwater.Section 3.2.2.2.6 oftheSRPreferstoLicensee Event Report (LER)50-275/94-023.ThisLER describes asituationinwhich centrifugal charging pumps hadbeenused as normal charging pumps for a substantial period oftime.Duringthis period the miniflowrecirculationorifices were enlargedthrougherosion.This enlargement could allowtheflowthroughthepumpto exceedtechnicalspecificationlimits.IntheLRA,the applicantstatesthatthe centrifugal chargingpumpsareused as safety injection pumps andarenotused as normal chargingpumps.The applicant further statesthatthe normal charging pumps are positive displacementpumpswhichdonothave miniflowrecirculationorifices.
LRA and SRP Sections 3.2.2.2.6 refer to LRA and SRP Tables 3.2.1-12. These tables address loss of material due to erosion of stainless steel high pressure safety injection (charging) pump miniflow orifice exposed to treated borated water. Section 3.2.2.2.6 of the SRP refers to Licensee Event Report (LER) 50-275/94-023. This LER describes a situation in which centrifugal charging pumps had been used as normal charging pumps for a substantial period of time. During this period the miniflow recirculation orifices were enlarged through erosion. This enlargement could allow the flow through the pump to exceed technical specification limits. In the LRA, the applicant states that the centrifugal charging pumps are used as safety injection pumps and are not used as normal charging pumps. The applicant further states that the normal charging pumps are positive displacement pumps which do not have miniflow recirculation orifices.
Issue:Initsreview ofLRATable 3.2.1-12 and LER 50-275/94-023, the staff notedthatthe applicant correctlyidentifiestheissue under consideration as erosion of the minifloworificesthrough prolongeduse.The staff also notedthatthe applicant statedthatitis currentlynotusingthe centrifugal pumps in a mannerwhichwouldresultin prolongeduse.The staff further notedthatone of the responsestotheevents of LER023wastoswitchfromusingthe centrifugal pumptothe positive displacement pumpfornormalinjection.
Issue:
Basedonthe ability of the applicanttoswitchfromusingthe centrifugalpumptothe positive displacementpumpfor normalinjection,the staff cannotconcludefromthe applicant's statementthatthe positive displacement pumpisbeingusedfor normalinjectionthatthe centrifugalpumphasnotbeenusedforthat purpose Inthepast.Pastuse of the centrifugalpumpfor normal injection couldindicatethat greater than acceptableerosionhas occurredormay occur with minimal additional useduringthe period of extended operation.
In its review of LRA Table 3.2.1-12 and LER 50-275/94-023, the staff noted that the applicant correctly identifies the issue under consideration as erosion of the miniflow orifices through prolonged use. The staff also noted that the applicant stated that it is currently not using the centrifugal pumps in a manner which would result in prolonged use. The staff further noted that one of the responses to the events of LER 50-275/94-023 was to switch from using the centrifugal pump to the positive displacement pump for normal injection. Based on the ability of the applicant to switch from using the centrifugal pump to the positive displacement pump for normal injection, the staff cannot conclude from the applicant's statement that the positive displacement pump is being used for normal injection that the centrifugal pump has not been used for that purpose In the past. Past use of the centrifugal pump for normal injection could indicate that greater than acceptable erosion has occurred or may occur with minimal additional use during the period of extended operation.
Request: Please provide information concerning the interchanability of the safetyinjectionpumps and the charging pumps.Additionally, please provide information concerning the operating history of the safety injection pumpssoas to allow the stafftodetermine whether these pumpshavebeenorwillbe operated for a sufficient period oftimetocauseerosion of the miniflow orifice.DEK ResponseTheKPS chargingpumpsare positive displacement pumpsanddonothavea mini-floworifice.TheKPS safety injectionpumpsare centrifugal pumpsandtheyarenot interchangeablewiththe positive displacement chargingpumps.Inaddition,the safetyinjectionpumpsareonlyoperatedforshortperiodsoftimeduringsurveillancetesting SerialNo.09-680DocketNo.50-305 Attachment1/Page21of40andfillingoftheSafetyInjectionaccumulators.Therefore,thesafetyinjectionpumpsmini-floworificesarenotsubjecttoprotractedconditionsthatwouldresultinerosion.
Request:
SerialNo.09-680DocketNo.50-305 Attachment1/Page22of40 RAI 3.3.2.3-3  
Please provide information concerning the interchanability of the safety injection pumps and the charging pumps. Additionally, please provide information concerning the operating history of the safety injection pumps so as to allow the staff to determine whether these pumps have been or will be operated for a sufficient period of time to cause erosion of the miniflow orifice.
DEK Response The KPS charging pumps are positive displacement pumps and do not have a mini-flow orifice. The KPS safety injection pumps are centrifugal pumps and they are not interchangeable with the positive displacement charging pumps. In addition, the safety injection pumps are only operated for short periods of time during surveillance testing
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 21 of 40 and filling of the Safety Injection accumulators. Therefore, the safety injection pumps mini-flow orifices are not subject to protracted conditions that would result in erosion.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 22 of 40 RAI 3.3.2.3-3


==Background:==
==Background:==
LRATables3.3.2-6,3.3.2-8, 3.3.2-19 and 3.3.2-27containitemswhichaddressthe exterior surfaces ofnonmetallic materials exposed to uncontrolled indoor air and the interior surfaces ofnonmetallicmaterials exposedtorawwater,dryair,lubeoil, andinertgas.The applicant proposesthatthereisnoaging effect associatedwiththis combination of material and environment andthatnoaging management program isrequired.The applicant proposesthatforthecomponent, material and environment combinationlistedthe aging effect being considered is not includedintheGALL Report(GenericNoteH).
 
Issue:Initsreview oftheseitems,the staff notedthat"nonmetallic material"isnot defined intheGALL Report andthat,interms oflicenserenewal,ithasnomeaning.The staff also noted that many polymericmaterialsare adversely affectedbyoxidizers(e.g.
LRA Tables 3.3.2-6, 3.3.2-8, 3.3.2-19 and 3.3.2-27 contain items which address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposed to raw water, dry air, lube oil, and inert gas. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no aging management program is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).
chlorine), ultraviolet light, andhightemperatures.
Issue:
Basedontheinformationprovided, the staff cannot concludethatnoagingeffectswill occurtothe combination of materials and environments under consideration.
In its review of these items, the staff noted that "non metallic material" is not defined in the GALL Report and that, in terms of license renewal, it has no meaning. The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.
Request:Giventhattheterm"non metallic"isverybroad, please identify the specific material underconsideration.Additionally, please justifywhythis materialisnot subjecttoagingunderthe conditionsbeingconsidered.
chlorine), ultraviolet light, and high temperatures. Based on the information provided, the staff cannot conclude that no aging effects will occur to the combination of materials and environments under consideration.
DEK ResponseDiscussionofInternalAgingEffects The non-metallic componentsshowninLRATable3.3.2-6(Service Water System)consistofvalves,piping,andpumps.The non-metallic components are constructedfromPolyvinyl Chloride(PCV)and PolyvinylideneFlouride(PVDF) materials.
Request:
The components are associatedwiththeService Water ChlorinationSystemandareexposedtosodium hypochloriteontheinternal surfaces(identifiedasaraw water environmentinTable3.3.2-6).Areviewofrecent industry and plant-specific operating experiencehasidentified crackingresultingfrom exposuretosodium hypochloriteinthe non-metallic piping associatedwiththeService Water ChlorinationSystem.Therefore,crackingduetochemical oxidationisaddedasanagingeffectfortheinternalsurfacesofthe non-metallic componentsinaraw water internal environmentshowninLRATable3.3.2-6.TheInternal Surfaces Monitoring program inspections performedbythe WorkControlProcessprogram (describedinDEKletterdated September25,2009[ADAMSAccessionNo.
Given that the term "non metallic" is very broad, please identify the specific material under consideration. Additionally, please justify why this material is not subject to aging under the conditions being considered.
ML092720184])willmanagethisagingeffectsuchthatthe component intended functions are maintained.
DEK Response Discussion of Internal Aging Effects The non-metallic components shown in LRA Table 3.3.2-6 (Service Water System) consist of valves, piping, and pumps. The non-metallic components are constructed from Polyvinyl Chloride (PCV) and Polyvinylidene Flouride (PVDF) materials. The components are associated with the Service Water Chlorination System and are exposed to sodium hypochlorite on the internal surfaces (identified as a raw water environment in Table 3.3.2-6). A review of recent industry and plant-specific operating experience has identified cracking resulting from exposure to sodium hypochlorite in the non-metallic piping associated with the Service Water Chlorination System. Therefore, cracking due to chemical oxidation is added as an aging effect for the internal surfaces of the non-metallic components in a raw water internal environment shown in LRA Table 3.3.2-6. The Internal Surfaces Monitoring program inspections performed by the Work Control Process program (described in DEK letter dated September 25, 2009 [ADAMS Accession No. ML092720184]) will manage this aging effect such that the component intended functions are maintained.
SerialNo.09-680DocketNo.50-305 Attachment1/Page23of40 Thenon-metalliccomponentsshowninLRATable3.3.2-8(Stationand Instrument AirSystem),whichhavenoagingeffectsassigned,consistoflubricatorsandoilers.Thebowlassociatedwiththese componentsisa polycarbonatematerial.Theinternalsurfacesofthe componentsareexposedtolubricatingoilanddriedair.Areviewofplantandindustryoperating experienceidentifiednoevidenceofpolymer degradationduetoexposuretodriedairorlubricatingoil.Therefore,noagingeffectswereappliedtotheinternalsurfacesofthesecomponents.
 
Thenon-metalliccomponentsshowninLRATable3.3.2-19(Diesel Generator System)arefilterhousingsinthedieselstartingairsystem.Thefilterhousingisa polycarbonatematerial.Theinternalsurfacesofthe componentsareexposedtodriedair.Areviewofplantandindustryoperating experienceidentifiednoevidenceofpolymer degradationduetoexposuretodriedair.Therefore,noagingeffectswereappliedtotheinternalsurfacesofthesefilterhousings.
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 23 of 40 The non-metallic components shown in LRA Table 3.3.2-8 (Station and Instrument Air System), which have no aging effects assigned, consist of lubricators and oilers. The bowl associated with these components is a polycarbonate material. The internal surfaces of the components are exposed to lubricating oil and dried air. A review of plant and industry operating experience identified no evidence of polymer degradation due to exposure to dried air or lubricating oil. Therefore, no aging effects were applied to the internal surfaces of these components.
The non-metallic componentshowninLRATable3.3.2-27 (MiscellaneousGasSystem)isflexibletubingusedtoconnectanitrogenbottletoaninstrumentairdryer.Thetubingispolyethylene.Theinternalsurfaceofthetubingisexposedtoinertnitrogengas.Areviewofplantandindustryoperating experienceidentifiednoevidenceof polymer degradationduetoexposuretoinertgases.Therefore,noagingeffectswereappliedtotheinternalsurfaceofthiscomponent.DiscussionofExternalAgingEffectsKewauneeislocatedinaruralareaontheshoreofLakeMichigan.Assuch, exposuretoharshchemicals(e.g.,sulfurdioxide)inthe atmospherethatcouldresultfromindustryisnotapplicabletotheexternalsurfacesofthe non-metallic components showninLRATables3.3.2-6,3.3.2-8,3.3.2-19and3.3.2-27.Additionally,these componentsarenormallyexposedto temperatureslessthan95&deg;F,whichiswellbelowthe temperatureratingofthe non-metallicmaterial.Theexternalsurfacesofthe componentswereevaluatedforreducedstrengthresultingfromexposuretoozoneandultraviolet(UV)radiation.However,these componentsarenotlocatednearhighvoltageelectrical equipmentandarenotexposedtodirectsunlight.Althoughthe metallic componentsareexposedtogeneralarea fluorescentlighting,areviewofplant operating experienceidentifiednoevidenceof polymer degradationasaresultofexposuretolimitedUVradiationinindoorlocations.Therefore,reducedstrengthduetoexposuretoozoneorUVradiationexposurewasnotidentifiedasan applicable agingeffectforthesecomponents.Basedontheabove,noagingeffectswereidentifiedthatcould adverselyaffecttheexternalsurfacesofthe non-metallic components.
The non-metallic components shown in LRA Table 3.3.2-19 (Diesel Generator System) are filter housings in the diesel starting air system. The filter housing is a polycarbonate material. The internal surfaces of the components are exposed to dried air. A review of plant and industry operating experience identified no evidence of polymer degradation due to exposure to dried air. Therefore, no aging effects were applied to the internal surfaces of these filter housings.
SerialNo.09-680DocketNo.50-305 Attachment1/Page24of40 RAI3.4.2.3.12-1
The non-metallic component shown in LRA Table 3.3.2-27 (Miscellaneous Gas System) is flexible tubing used to connect a nitrogen bottle to an instrument air dryer. The tubing is polyethylene. The internal surface of the tubing is exposed to inert nitrogen gas. A review of plant and industry operating experience identified no evidence of polymer degradation due to exposure to inert gases. Therefore, no aging effects were applied to the internal surface of this component.
Discussion of External Aging Effects Kewaunee is located in a rural area on the shore of Lake Michigan. As such, exposure to harsh chemicals (e.g., sulfur dioxide) in the atmosphere that could result from industry is not applicable to the external surfaces of the non-metallic components shown in LRA Tables 3.3.2-6, 3.3.2-8, 3.3.2-19 and 3.3.2-27. Additionally, these components are normally exposed to temperatures less than 95&deg;F, which is well below the temperature rating of the non-metallic material.           The external surfaces of the components were evaluated for reduced strength resulting from exposure to ozone and ultraviolet (UV) radiation. However, these components are not located near high voltage electrical equipment and are not exposed to direct sunlight. Although the non-metallic components are exposed to general area fluorescent lighting, a review of plant operating experience identified no evidence of polymer degradation as a result of exposure to limited UV radiation in indoor locations. Therefore, reduced strength due to exposure to ozone or UV radiation exposure was not identified as an applicable aging effect for these components.
Based on the above, no aging effects were identified that could adversely affect the external surfaces of the non-metallic components.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 24 of 40 RAI3.4.2.3.12-1


==Background:==
==Background:==
LRATable 3.4.2-12containsitemswhichaddressthe exterior surfaces ofnonmetallic materials exposed to uncontrolled indoor air and the interior surfaces ofnonmetallic materials exposedtotreated waterorsteam.The applicant proposesthatthereisno aging effect associatedwiththis combination of material and environment andthatno aging management programisrequired.The applicant proposesthatforthe component, material and environment combinationlistedthe aging effect being consideredisnot includedintheGALL Report(GenericNoteH).
 
Issue:Initsreview oftheseitems,the staff noted that"non metallic material"isnot defined intheGALLReport andthat,interms oflicenserenewal,ithasnomeaning.The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.chlorine), ultraviolet light, andhightemperatures.
LRA Table 3.4.2-12 contains items which address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposed to treated water or steam. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no aging management program is required.             The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).
Basedontheinformationprovided, the staff cannotconcludethatno agingeffectswill occurtothe combination of materials and environments under consideration.
Issue:
Request:Giventhattheterm"non metallic"isverybroad, please identify the specific materialunderconsideration.Additionally, please justifywhythis materialisnot subjecttoaging under the conditionsbeingconsidered.
In its review of these items, the staff noted that "non metallic material" is not defined in the GALL Report and that, in terms of license renewal, it has no meaning. The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.
DEK Response The non-metallic componentsshowninLRATable3.4.2-12, Secondary SamplingSystem,consistoffilterhousings, conductivitycellhousings,andpipingfabricatedfrom polysulfone, polyethersulfone,andpolyvinylchloride(PVC),respectively.The componentsareassociatedwiththeanalytical instrumentation panel (secondarysamplingstation)andareexposedtosamplefluidsfrom chemistry-controlled secondaryplantsystemsontheinternalsurfacesandan air-indoor uncontrolled environment ontheexternalsurfaces.Sincethesamplefluidsarefrom chemistry-controlled secondaryplantsystems,theinternalsurfacesofthe componentsarenotexposedto significantlevelsofcontaminants,suchaschlorine.Additionally,these componentsarelocated downstreamofthesecondarysamplecoolersandarenotexposedtoelevated temperatures.Therefore,noagingeffectswereidentifiedthatcould adverselyaffecttheinternalsurfacesofthese non-metallic components.KewauneeislocatedinaruralareaontheshoreofLakeMichigan.Assuch, exposuretoharshchemicals(e.g.,sulfurdioxide)inthe atmospherethatcouldresultfromlocal SerialNo.09-680DocketNo.50-305 Attachment1/Page25of40industryisnot applicabletotheexternalsurfacesofthesecomponents.Theexternalsurfaceswereevaluatedforthepotentialforreducedstrengthresultingfromexposuretoozoneand ultraviolet(UV)radiation.However,these componentsarenotlocatednearhighvoltageelectrical equipmentandarenotexposedtodirectsunlight.Although these non-metallic componentsareexposedtogeneralarea fluorescentlighting,areviewofplantoperating experienceidentifiednoevidenceofpolymer degradation duetoexposuretoUVradiationfromlightingsources.Therefore,reducedstrengthduetoexposuretoozoneorUVradiationexposurewasnotidentifiedasanapplicableaffect.Basedontheabove,noagingeffectswereidentifiedthatcould adverselyaffecttheexternalsurfacesofthese non-metallic components.
chlorine), ultraviolet light, and high temperatures. Based on the information provided, the staff cannot conclude that no aging effects will occur to the combination of materials and environments under consideration.
SerialNo.09-680DocketNo.50-305 Attachment1/Page26of40 RAI 3.5.2.3-6  
Request:
Given that the term "non metallic" is very broad, please identify the specific material under consideration. Additionally, please justify why this material is not subject to aging under the conditions being considered.
DEK Response The non-metallic components shown in LRA Table 3.4.2-12, Secondary Sampling System, consist of filter housings, conductivity cell housings, and piping fabricated from polysulfone, polyethersulfone, and polyvinyl chloride (PVC), respectively.             The components are associated with the analytical instrumentation panel (secondary sampling station) and are exposed to sample fluids from chemistry-controlled secondary plant systems on the internal surfaces and an air-indoor uncontrolled environment on the external surfaces.
Since the sample fluids are from chemistry-controlled secondary plant systems, the internal surfaces of the components are not exposed to significant levels of contaminants, such as chlorine.         Additionally, these components are located downstream of the secondary sample coolers and are not exposed to elevated temperatures. Therefore, no aging effects were identified that could adversely affect the internal surfaces of these non-metallic components.
Kewaunee is located in a rural area on the shore of Lake Michigan. As such, exposure to harsh chemicals (e.g., sulfur dioxide) in the atmosphere that could result from local
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 25 of 40 industry is not applicable to the external surfaces of these components. The external surfaces were evaluated for the potential for reduced strength resulting from exposure to ozone and ultraviolet (UV) radiation. However, these components are not located near high voltage electrical equipment and are not exposed to direct sunlight. Although these non-metallic components are exposed to general area fluorescent lighting, a review of plant operating experience identified no evidence of polymer degradation due to exposure to UV radiation from lighting sources. Therefore, reduced strength due to exposure to ozone or UV radiation exposure was not identified as an applicable affect.
Based on the above, no aging effects were identified that could adversely affect the external surfaces of these non-metallic components.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 26 of 40 RAI 3.5.2.3-6


==Background:==
==Background:==
LRATables 3.5.2-4, 3.5.2-12 and 3.5.2-14 containitemswhich address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposedtorawwater.The applicant proposes thatthereisno aging effect associatedwiththis combination of material and environment andthatno aging management programisrequired.The applicant proposesthatfor the component, material and environment combination listed the aging effect being consideredisnot includedintheGALL Report (GenericNoteH).Issue:Inits review oftheseitems,the staff notedthat"non metallic material" is not defined intheGALL Report andthat,interms oflicenserenewal,ithasno meaning.The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.chlorine), ultraviolet light, and high temperatures.
 
Basedonthe information provided, the staff cannot concludethatno aging effects will occurtothe combination of materials and environments under consideration.
LRA Tables 3.5.2-4, 3.5.2-12 and 3.5.2-14 contain items which address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposed to raw water. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no aging management program is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).
Request:Giventhattheterm"non metallic"isverybroad, please identify the specific material under consideration.
Issue:
Additionally, please justifywhythis material is not subject to aging under the conditions being considered.
In its review of these items, the staff noted that "non metallic material" is not defined in the GALL Report and that, in terms of license renewal, it has no meaning. The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.
DEK Response The non-metallic structural membershowninLRATable3.5.2-4,whichhasnoagingeffectsassigned,consistsofwoodplanking.Thewoodplankingisexposedtoan external air-indoor uncontrolled environment.Thewoodplankingis protected from weatherandisnotlocatedinasoil environmentwhichcouldresultinlossof material orchangeinmaterialproperties.Areviewofplantand industry operating experienceidentifiedno evidenceofwood degradationdueto exposuretoanexternal air-indoor uncontrolled environment.
chlorine), ultraviolet light, and high temperatures. Based on the information provided, the staff cannot conclude that no aging effects will occur to the combination of materials and environments under consideration.
Therefore,noagingeffectsareappliedtothis component.
Request:
The non-metallic structural membershowninLRATable3.5.2-12,whichhasnoagingeffectsassigned,consistsof traveling waterscreencovers.Thetravelingwaterscreencoversare fiberglassmaterial.The fiberglasscoversareexposedtoanexternal indoor uncontrolled environmentandaninternalrawwater environment.
Given that the term "non metallic" is very broad, please identify the specific material under consideration. Additionally, please justify why this material is not subject to aging under the conditions being considered.
The fiberglasscoversdonot experience ultravioletradiationorozoneexposureorhighvoltage currentswhichcouldresultinlossofstrength.Areviewofplantand industry operating experienceidentifiedno evidence of fiberglass degradationdueto exposuretoan external air-indoor uncontrolled environmentoraninternalraw water environment.
DEK Response The non-metallic structural member shown in LRA Table 3.5.2-4, which has no aging effects assigned, consists of wood planking. The wood planking is exposed to an external air-indoor uncontrolled environment. The wood planking is protected from weather and is not located in a soil environment which could result in loss of material or change in material properties. A review of plant and industry operating experience identified no evidence of wood degradation due to exposure to an external air-indoor uncontrolled environment. Therefore, no aging effects are applied to this component.
Therefore, no aging effects are appliedtothis component.
The non-metallic structural member shown in LRA Table 3.5.2-12, which has no aging effects assigned, consists of traveling water screen covers. The traveling water screen covers are fiberglass material. The fiberglass covers are exposed to an external air-indoor uncontrolled environment and an internal raw water environment. The fiberglass covers do not experience ultraviolet radiation or ozone exposure or high voltage currents which could result in loss of strength. A review of plant and industry operating experience identified no evidence of fiberglass degradation due to exposure to an external air-indoor uncontrolled environment or an internal raw water environment.
SerialNo.09-680DocketNo.50-305 Attachment1/Page27of40 The non-metallic commoditygroupshowninLRATable3.5.2-14,whichhasnoagingeffectsassigned,consistsoffireboots.Thefirebootsarefiberglassmaterial.Thefiberglassbootsareexposedtoanexternal air-indoor uncontrolled environment.
Therefore, no aging effects are applied to this component.
Thefiberglassbootsdonot experienceultravioletradiationorozone exposureorhighvoltagecurrentswhichcouldresultinlossofstrength.Areviewofplantandindustryoperatingexperienceidentifiednoevidenceoffiberglass degradationduetoexposuretoanexternal air-indoor uncontrolledenvironment.Therefore,noagingeffectsareappliedtothiscomponent.
 
The non-metallic commoditygroupshowninLRATable3.5.2-14,whichhasnoagingeffectsassigned,consistsofinsulation.Theinsulationisfabricatedofcalciumsilicate,expandedsilicate,andfiberglassmaterial.Thematerialsareexposedtoanexternal air-indoor uncontrolled environment.Thesematerialsarenotexposedto ultravioletradiationorozoneexposureorhighvoltagecurrents,chemicalsor temperatures whichcouldresultinlossofstrength.Areviewofplantandindustryoperating experienceidentifiednoevidenceofcalciumsilicate,expandedsilicate,and fiberglass degradationduetoexposuretoanexternal air-indooruncontrolledenvironment.Therefore,noagingeffectsareappliedtothiscomponent.
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 27 of 40 The non-metallic commodity group shown in LRA Table 3.5.2-14, which has no aging effects assigned, consists of fire boots. The fire boots are fiberglass material. The fiberglass boots are exposed to an external air-indoor uncontrolled environment. The fiberglass boots do not experience ultraviolet radiation or ozone exposure or high voltage currents which could result in loss of strength. A review of plant and industry operating experience identified no evidence of fiberglass degradation due to exposure to an external air-indoor uncontrolled environment. Therefore, no aging effects are applied to this component.
SerialNo.09-680DocketNo.50-305 Attachment1/Page28of40 RAI4.2.1-1
The non-metallic commodity group shown in LRA Table 3.5.2-14, which has no aging effects assigned, consists of insulation. The insulation is fabricated of calcium silicate, expanded silicate, and fiberglass material. The materials are exposed to an external air-indoor uncontrolled environment. These materials are not exposed to ultraviolet radiation or ozone exposure or high voltage currents, chemicals or temperatures which could result in loss of strength. A review of plant and industry operating experience identified no evidence of calcium silicate, expanded silicate, and fiberglass degradation due to exposure to an external air-indoor uncontrolled environment. Therefore, no aging effects are applied to this component.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 28 of 40 RAI4.2.1-1


==Background:==
==Background:==
Theevaluation of neutron f1uence is providedinLRASection 4.2.1,"Neutron Fluence." Issue/Request:TheLRAdoes not provide a USAR Supplement summary description ofLRASection 4.2.1inLRA AppendixA,"UpdatedSafety Analysis Report Supplement." PleaseprovideanUSAR supplement summary description of the evaluation of neutron f1uence for52.1effectivefull power years.DEK Response The followingwillbeaddedtoLRA AppendixA,USAR Supplement,SectionA3.1: "The calculationofneutronfluencetowhich reactor vessel materials are exposedisan importantinputtothe evaluation of reactor vessel neutron embrittlementandis governed by regulatory requirements.
 
WCAP-16641 (Reference A3.6-6)provides the calculation of Kewauneereactorvessel neutron fluence projectionstoEOLR(i.e.,60yearplantlifetime)basedon52.1EFPY.
The evaluation of neutron f1uence is provided in LRA Section 4.2. 1, "Neutron Fluence."
Neutron exposure uptoCycle27wasbaseduponactualplant operating history, including powerupratethat occurredduringCycle26.Neutron exposure projectionsbeyondtheendofCycle27werebaseduponan operating scenario that consistedofaseriesof18month operating cycles followedbya25day refuelingoutage.Thereactorwas consideredtobe operatingatfull powerfortheentire18monthcycle.Thisfull power period coupledwiththe25day refuelingoutageresultedinanet capacity factor of 95.6%withatotal operatingtimeof33.0EFPYatEOLand52.1EFPYatEOLR.Theneutron exposure projectionswerealsobasedon the continueduseoflow neutron leakage fuel management.
Issue/Request:
Kewaunee reactor vessel surveillance CapsuleTwasremovedin2004(thefifth capsuleremovedfromthereactor)and WCAP-16641 documentstheresultsof the fluence evaluationforthe specimens.
The LRA does not provide a USAR Supplement summary description of LRA Section 4.2. 1 in LRA Appendix A, "Updated Safety Analysis Report Supplement." Please provide an USAR supplement summary description of the evaluation of neutron f1uence for 52. 1 effective full power years.
The fluence calculations concluded that Capsule T surveillance specimensreceiveda fluence of 5.62E+19n/crn"(E>1.0MeV)after irradiationto24.6EFPYandthepeak reactor vessel clad/base metal interface fluenceafter24.6EFPYofplant operation was 2.60E+19 n/cm"(E>1.0MeV).The Capsule T specimens have received a fluence equivalent to slightly greaterthan52.1EFPY.The maximum vessel exposures occuronthe intermediateshellbase materialwithall other vessel materials experiencing a lower neutron exposure.Certain materialsinthe extendedbeltline(inletnozzles,inletandoutletnozzleto uppershellwelds, uppershellforging,and intermediateshellto uppershellgirthweld)are projectedtoreceive fluence greater than1.0E+17 n/cm"duringthe40-60year operating period."
DEK Response The following will be added to LRA Appendix A, USAR Supplement, Section A3.1 :
SerialNo.09-680DocketNo.50-305 Attachment1/Page29of40ThefollowingwillbeaddedtoLRA AppendixA,USARSupplement,SectionA3.6:
        "The calculation of neutron fluence to which reactor vessel materials are exposed is an important input to the evaluation of reactor vessel neutron embrittlement and is governed by regulatory requirements. WCAP-16641 (Reference A3.6-6) provides the calculation of Kewaunee reactor vessel neutron fluence projections to EOLR (i.e., 60 year plant lifetime) based on 52.1 EFPY. Neutron exposure up to Cycle 27 was based upon actual plant operating history, including power uprate that occurred during Cycle 26. Neutron exposure projections beyond the end of Cycle 27 were based upon an operating scenario that consisted of a series of 18 month operating cycles followed by a 25 day refueling outage. The reactor was considered to be operating at full power for the entire 18 month cycle. This full power period coupled with the 25 day refueling outage resulted in a net capacity factor of 95.6% with a total operating time of 33.0 EFPY at EOL and 52.1 EFPY at EOLR. The neutron exposure projections were also based on the continued use of low neutron leakage fuel management.
"6.WCAP-16641,Revision0,AnalysisofCapsuleTfromtheDominionEnergyKewauneePowerStationReactorVesselRadiation Surveillance Program, WestinghouseElectricCompany,LLC,October,2006."
Kewaunee reactor vessel surveillance Capsule T was removed in 2004 (the fifth capsule removed from the reactor) and WCAP-16641 documents the results of the fluence evaluation for the specimens. The fluence calculations concluded that Capsule T surveillance specimens received a fluence of 5.62E+19 n/crn" (E>1.0 MeV) after irradiation to 24.6 EFPY and the peak reactor vessel clad/base metal interface fluence after 24.6 EFPY of plant operation was 2.60E+19 n/cm" (E>1.0 MeV). The Capsule T specimens have received a fluence equivalent to slightly greater than 52.1 EFPY. The maximum vessel exposures occur on the intermediate shell base material with all other vessel materials experiencing a lower neutron exposure. Certain materials in the extended beltline (inlet nozzles, inlet and outlet nozzle to upper shell welds, upper shell forging, and intermediate shell to upper shell girth weld) are projected to receive fluence greater than 1.0E+ 17 n/cm" during the 40 - 60 year operating period."
SerialNo.09-680DocketNo.50-305 Attachment1/Page30of40RAI3.1.2.1.2-1
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 29 of 40 The following will be added to LRA Appendix A, USAR Supplement, Section A3.6:
      "6. WCAP-16641, Revision 0, Analysis of Capsule T from the Dominion Energy Kewaunee Power Station Reactor Vessel Radiation Surveillance Program, Westinghouse Electric Company, LLC, October, 2006."
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 30 of 40 RAI 3.1.2.1.2-1


==Background:==
==Background:==


The AMP for managingtheloss offracturetoughnessduetothermalaging embrittlement of reactor coolantsystemClass 1pumpcasing, andvalvebodies and bonnets, constructed of cast authentic stainless steel (CASS)materials consists of the American Society of Mechanical Engineers(ASME)SectionXIInserviceInspection (lSI), SubsectionsIWB,IWC, and IWD programwithanexceptioninthattheEdition of the ASMESectionXICodeis differentthanthat oftheGALL AMPXI.M12.Inaddition,theLRAstatesthattheCASSClass 1reactorcoolantsystemloop pipinghasbeen evaluatedfortheeffects of aging andfoundtobenot susceptibletothermal agingembrittlement,thereforethereisno requirementtomanagetheeffects ofthermalaging embrittlement of CASS reactor coolant loop pipingforthe period of extended operation.
The AMP for managing the loss of fracture toughness due to thermal aging embrittlement of reactor coolant system Class 1 pump casing, and valve bodies and bonnets, constructed of cast authentic stainless steel (CASS) materials consists of the American Society of Mechanical Engineers (ASME) Section XI Inservice Inspection (lSI), Subsections IWB, IWC, and IWD program with an exception in that the Edition of the ASME Section XI Code is different than that of the GALL AMP XI.M12. In addition, the LRA states that the CASS Class 1 reactor coolant system loop piping has been evaluated for the effects of aging and found to be not susceptible to thermal aging embrittlement, therefore there is no requirement to manage the effects of thermal aging embrittlement of CASS reactor coolant loop piping for the period of extended operation.
Issue: The assessment oftheloss offracturetoughnessduetothermal embrittlement is based on calculatedferritelevelsusingtheHull's equivalent factors.Other procedures for calculating ferrite contentmayresultin a non-conservative estimation ofthefracture toughness ofthesteel.TheGALLReportstates,"In the susceptibility screeningmethod,ferrite content is calculatedbyusingtheHull's equivalent factors (described inNUREG/CR-4513,Rev 1)or a method producing an equivalent level of accuracy (+/-6%deviationbetween measured and calculated values)." Request: Confirm whethertheHull's equivalentfactorswereusedtodeterminethedeltaferrite content oftheCASSmaterials, andiftheywerenot,verifythatthe method produced an equivalent level of accuracy.DEK Response Susceptibilityscreeningforthecastausteniticstainlesssteel(CASS)reactorcoolantlooppipingwasperformed consistentwiththeletterfrom ChristopherGrimes,NuclearRegulatoryCommissiontoDouglasWalters,NuclearEnergyInstitute,LicenseRenewalIssueNo.98-0030,"ThermalAging EmbrittlementofCast Austenitic Stainless Steel Components,"datedMay19,2000[ADAMSAccessionNo.
Issue:
ML003717179],withtheexceptionthatdelta-ferritecontentwasdeterminedusingthemethodoutlinedinASTM A800,"StandardPracticefor Steel Casting, Austenitic Alloy, Estimating Ferrite Content Thereof,"ratherthantheHull's equivalentfactorsmethodidentifiedintheletter.InaccordancewithASTMA800,estimationofferritecontentinthebasemetalofthereactorcoolantlooppipingwas performedbyanalysisofthechemicalcompositionofthecastings.Theferritecontentofthecastingwasestimatedfromtheequationofthe SerialNo.09-680DocketNo.50-305 Attachment 1/Page 31of40centrallineofthe Schoeferdiagramatthecompositionratioof"chromiumequivalent" (Cr e)to"nickelequivalent"(Ni e)determinedfromtheformulainASTMA800.TheASTM A800 Schoeferdiagrammethoddetails,providedin Appendix X1totheStandard,includeadescriptionofpotentialerrorassociatedwiththeestimationofferritecontentbasedonchemicalcomposition.Theprobableerror determinedintheStandardis approximately+3.5%/-2.5%ferriteatferritecontentof5%;+4.5%/-3.5%at10%ferrite;+6%/-4.5%at15%ferrite;and+8%/-5.5%at20%ferritecontent.AsstatedintheNRCLicenseRenewalIssueNo.98-0030letterdatedMay19,2000,theHull'sequivalentfactorsmethodproducesresultswith+/-6%ferritepotentialerror.ThedifferenceinpotentialerrorathigherlevelsofferritecontentbetweentheHull'sequivalentfactorsmethodandthe SchoeferdiagrammethodprovidedinASTMA800issmall,andthe Schoeferdiagrammethodusedforestimatingtheferritecontentofthesteelwas consideredtoprovideanacceptablelevelofaccuracy.
The assessment of the loss of fracture toughness due to thermal embrittlement is based on calculated ferrite levels using the Hull's equivalent factors. Other procedures for calculating ferrite content may result in a non-conservative estimation of the fracture toughness of the steel. The GALL Report states, "In the susceptibility screening method, ferrite content is calculated by using the Hull's equivalent factors (described in NUREG/CR-4513, Rev 1) or a method producing an equivalent level of accuracy (+/-6%
SerialNo.09-680DocketNo.50-305 Attachment1/Page32of40 RAI 3.1.2.1.3-1
deviation between measured and calculated values)."
Request:
Confirm whether the Hull's equivalent factors were used to determine the delta ferrite content of the CASS materials, and if they were not, verify that the method produced an equivalent level of accuracy.
DEK Response Susceptibility screening for the cast austenitic stainless steel (CASS) reactor coolant loop piping was performed consistent with the letter from Christopher Grimes, Nuclear Regulatory Commission to Douglas Walters, Nuclear Energy Institute, License Renewal Issue No. 98-0030, "Thermal Aging Embrittlement of Cast Austenitic Stainless Steel Components," dated May 19, 2000 [ADAMS Accession No. ML003717179], with the exception that delta-ferrite content was determined using the method outlined in ASTM A800, "Standard Practice for Steel Casting, Austenitic Alloy, Estimating Ferrite Content Thereof," rather than the Hull's equivalent factors method identified in the letter.
In accordance with ASTM A800, estimation of ferrite content in the base metal of the reactor coolant loop piping was performed by analysis of the chemical composition of the castings. The ferrite content of the casting was estimated from the equation of the
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 31 of 40 central line of the Schoefer diagram at the composition ratio of "chromium equivalent" (Cre) to "nickel equivalent" (Ni e) determined from the formula in ASTM A800. The ASTM A800 Schoefer diagram method details, provided in Appendix X1 to the Standard, include a description of potential error associated with the estimation of ferrite content based on chemical composition. The probable error determined in the Standard is approximately +3.5% / -2.5% ferrite at ferrite content of 5%; +4.5% / -3.5% at 10%
ferrite; +6% / -4.5% at 15% ferrite; and +8% / -5.5% at 20% ferrite content. As stated in the NRC License Renewal Issue No. 98-0030 letter dated May 19, 2000, the Hull's equivalent factors method produces results with +/- 6% ferrite potential error. The difference in potential error at higher levels of ferrite content between the Hull's equivalent factors method and the Schoefer diagram method provided in ASTM A800 is small, and the Schoefer diagram method used for estimating the ferrite content of the steel was considered to provide an acceptable level of accuracy.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 32 of 40 RAI 3.1.2.1.3-1


==Background:==
==Background:==


The program for managing crackingduetostresscorrosion cracking of austenitic stainless steel reactor coolant system components(AMRlineitem3.1.1-68)consists ofPrimaryWater Chemistry programwhereasthe program recommendedintheGALLReport,forthesamelineitems, consists of ASMESectionXIInserviceInspection (SubsectionsIWB,IWC, and IWO)andPrimaryWater Chemistryprogram.TheLRAfurtherstatesthattheKPS program is consistentwiththeGALLAMP.
The program for managing cracking due to stress corrosion cracking of austenitic stainless steel reactor coolant system components (AMR line item 3. 1.1-68) consists of Primary Water Chemistry program whereas the program recommended in the GALL Report, for the same line items, consists of ASME Section XI Inservice Inspection (Subsections IWB, IWC, and IWO) and Primary Water Chemistry program. The LRA further states that the KPS program is consistent with the GALL AMP.
Issue:InLRATable3.1.1,lineitem3.1.1-68, the applicant statedthatthe crackingdueto stress-corrosion cracking of austenitic stainless steel reactor coolantpumpthermal barriers heat exchanger, pressurizermanway, and reactor coolant system thermalsleevesis managedbythePrimaryWater Chemistry program while stress-corrossioncracking(SCC) of stainless steelpiping,fittings, pumpcasings,valvebodies,nozzles,etc.is managedbyPrimaryWater Chemistry as well as ASMESectionXIInserviceInspectionprogram.The applicant further statedthattheKPS program is consistentwiththeGALLAMP.Itisnot clear how the applicant's program for stainless steel reactor coolantpumpthermalbarriers heat exchanger, pressurizermanway, and reactor coolantsystemthermalsleevesis consistentwiththeGALLAMP.
Issue:
Request: Explain how the applicant's programtomanage crackingduetoSCCis consistent with the programs recommendedintheGALLReport.Also,describe how the effectivenessofthe programisverifiedtoensurethatcrackingisnot accruing and the structural and functional integrity of the componentswillbe maintained during extended operation.
In LRA Table 3. 1.1, line item 3. 1.1-68, the applicant stated that the cracking due to stress-corrosion cracking of austenitic stainless steel reactor coolant pump thermal barriers heat exchanger, pressurizer man way, and reactor coolant system thermal sleeves is managed by the Primary Water Chemistry program while stress-corrossion cracking (SCC) of stainless steel piping, fittings, pump casings, valve bodies, nozzles, etc. is managed by Primary Water Chemistry as well as ASME Section XI Inservice Inspection program. The applicant further stated that the KPS program is consistent with the GALL AMP. It is not clear how the applicant's program for stainless steel reactor coolant pump thermal barriers heat exchanger, pressurizer manway, and reactor coolant system thermal sleeves is consistent with the GALL AMP.
DEK ResponseForthereactorcoolantpumpthermalbarriers(heatexchanger)andthe pressurizermanway(includingstainlesssteelinsert),theASMESectionXIInserviceInspection program, SubsectionsIWB,IWC,andIWD,isaddedasanadditionalaging managementprogramandwillprovideverificationofthe effectivenessofthePrimary Water Chemistryprogramfor managementofcrackingduetostresscorrosioncracking.Thischangeprovides consistencywithNUREG-1801(Item3.1.1-68).Forthe non-pressure boundary thermalsleeves,theOne-TimeInspectionprogramwithintheWorkControlProcessprogram,asdescribedinDEKletterdated September25,2009(DEKSerialNo.09-597)[ADAMSAccessionNo.ML092720184],isaddedasanadditionalaging managementprogramandwillprovideverificationofthe effectivenessofthePrimary Water Chemistryprogramfor managementofcrackingduetostresscorrosioncracking.The One-TimeInspectionprogramwithintheWorkControl SerialNo.09-680DocketNo.50-305 Attachment1/Page33of40ProcessprogramusesNDE techniquesthathavebeendeterminedtobeeffectivefortheidentificationofstresscorrosioncrackinginstainlesssteel.The inspections willverifythat unacceptable degradationisnotoccurringformaterialand environment combinationsthatinclude stainlesssteelinprimarytreatedwater.Indicationsofdegradationwouldresultinan engineeringreviewoftheconditionthroughtheCorrectiveActionProgramandcouldresultinfurthercorrectiveactions,suchasanexpansionoftheinspectionscope.
Request:
SerialNo.09-680 Docket No.50-305 Attachment 1/Page34of40 RAI4.7.5-1
Explain how the applicant's program to manage cracking due to SCC is consistent with the programs recommended in the GALL Report. Also, describe how the effectiveness of the program is verified to ensure that cracking is not accruing and the structural and functional integrity of the components will be maintained during extended operation.
DEK Response For the reactor coolant pump thermal barriers (heat exchanger) and the pressurizer manway (including stainless steel insert), the ASME Section XI Inservice Inspection program, Subsections IWB, IWC, and IWD, is added as an additional aging management program and will provide verification of the effectiveness of the Primary Water Chemistry program for management of cracking due to stress corrosion cracking.
This change provides consistency with NUREG-1801 (Item 3.1.1-68).
For the non-pressure boundary thermal sleeves, the One-Time Inspection program within the Work Control Process program, as described in DEK letter dated September 25, 2009 (DEK Serial No. 09-597) [ADAMS Accession No. ML092720184], is added as an additional aging management program and will provide verification of the effectiveness of the Primary Water Chemistry program for management of cracking due to stress corrosion cracking. The One-Time Inspection program within the Work Control
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 33 of 40 Process program uses NDE techniques that have been determined to be effective for the identification of stress corrosion cracking in stainless steel. The inspections will verify that unacceptable degradation is not occurring for material and environment combinations that include stainless steel in primary treated water. Indications of degradation would result in an engineering review of the condition through the Corrective Action Program and could result in further corrective actions, such as an expansion of the inspection scope.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 34 of 40 RAI4.7.5-1


===Background===
===Background===
Section 4.7.5 oftheLRAdescribesthe reactor coolantloopplpmgflawtoleranceevaluationto account for susceptibility oftheCASS piping materialstothermalagingembrittlement.The applicant statedthatanevaluation of the susceptibility oftheloop pipingtothermalaging and the potentialforflawgrowthinthe pipingdueto reducedfracturetoughnesshasbeen performed consistentwiththe recommendations of GALLAMPXI.M12.
Section 4.7.5 of the LRA describes the reactor coolant loop plpmg flaw tolerance evaluation to account for susceptibility of the CASS piping materials to thermal aging embrittlement. The applicant stated that an evaluation of the susceptibility of the loop piping to thermal aging and the potential for flaw growth in the piping due to reduced fracture toughness has been performed consistent with the recommendations of GALL AMP XI.M12.
Issue: The applicant statedinLRASection 4.7.5: 'The limiting initialflawdepthforan aspect ratio of 6isinthe crossover leg (28%through-wall).Theflawtolerance evaluationconcludesthatflaw ofthisinitialsizewouldnot grow to criticalsize(i.e., asizethatcouldresultin pipingfailureatdesignbasisloadingconditions,duringan additional 30 years of service." Basedontheseresultsthe applicant concludedthatthereisno requirementtomanagetheeffects of thermal aging embrittlement of CASS reactor coolant loop pipingforthe period of extendedoperation.However,the applicantdidnot provide sufficient details regarding appliedstressesin specificpipesections,orcycliccrackgrowthrates,or boundingfracturetoughness of thermally agedCASS,toverify the applicant's statementthattheinitialflawwill not grow to criticalsizeorto check the criticalflawsize.Forexample,the applicant indicatedthatthe number of occurrencesofdesigntransients consideredintheanalysiswere basedontherevisionsfor Kewaunee 7.4%uprating and steam generatorreplacement,however,itisnot clear whether the 7.4%upratingwas considered in determiningthedesignstressesfortheevaluation.Also, although the applicant statedthatthattheloop piping was constructed of CF-8M steelwithlessthan 25%deltaferrite,the applicantdidnotconfirmthatitdidnotcontainniobium.Typically,niobiumisnot specifiedinCF-8Msteel.The recommendations of XI.M12 are not applicabletoniobium bearingsteels.Inaddition, the applicant statedthatan environmental factor of 2 was appliedtothe crack growthreferencecurvesfor austenitic stainless steel in air to accountforthe effect of pressurized water reactor (PWR)environmentongrowthrates.However,the applicantdidnot providethebasisfor choosing an environmentalfactorof 2.Several recentstudieshave reported data showingthatthefatigue crackgrowthratescanbe enhanced appreciablyinPWR primary coolant environmentatlowloadingfrequencies.
Issue:
Request:Providethefollowing information:
The applicant stated in LRA Section 4.7.5: 'The limiting initial flaw depth for an aspect ratio of 6 is in the crossover leg (28% through-wall). The flaw tolerance evaluation concludes that flaw of this initial size would not grow to critical size (i.e., a size that could result in piping failure at design basis loading conditions, during an additional 30 years of service." Based on these results the applicant concluded that there is no requirement to manage the effects of thermal aging embrittlement of CASS reactor coolant loop piping for the period of extended operation. However, the applicant did not provide sufficient details regarding applied stresses in specific pipe sections, or cyclic crack growth rates, or bounding fracture toughness of thermally aged CASS, to verify the applicant's statement that the initial flaw will not grow to critical size or to check the critical flaw size. For example, the applicant indicated that the number of occurrences of design transients considered in the analysis were based on the revisions for Kewaunee 7.4% uprating and steam generator replacement, however, it is not clear whether the 7.4% uprating was considered in determining the design stresses for the evaluation. Also, although the applicant stated that that the loop piping was constructed of CF-8M steel with less than 25% delta ferrite, the applicant did not confirm that it did not contain niobium.       Typically, niobium is not specified in CF-8M steel. The recommendations of XI.M12 are not applicable to niobium bearing steels. In addition, the applicant stated that an environmental factor of 2 was applied to the crack growth reference curves for austenitic stainless steel in air to account for the effect of pressurized water reactor (PWR) environment on growth rates. However, the applicant did not provide the basis for choosing an environmental factor of 2. Several recent studies have reported data showing that the fatigue crack growth rates can be enhanced appreciably in PWR primary coolant environment at low loading frequencies.
1.Confirmthattheloop piping materialisnotniobiumbearing.2.ConfirmthattheKewaunee 7.4%upratingwas considered in determiningthedesignstressesfortheflawtoleranceevaluation.
Request:
SerialNo.09-680DocketNo.50-305 Attachment1/Page35of403.Thedetailsregardingflawgrowthanalyses,inparticular,thetechnicalbasisforthe choice of the environmental factor of 2forfatiguecrackgrowthratesinPWR environment.
Provide the following information:
DEK Response1.Thereactorcoolantlooppipingwas supplied in accordancewithmaterial specification American Society for Testing and Materials(ASTM)A351,Grade8M.This specificationdoesnotrequiretheadditionofniobium(or columbium) forGradeCF-8Msteel.
: 1. Confirm that the loop piping material is not niobium bearing.
Additionally,thechemical compositionsforthelooppipingheatswerereviewedandtherewasno indicationofniobium(or columbium) content.2.The Kewaunee7.4%upratingwas considered in determiningthedesign stresses fortheflaw tolerance evaluation.3.Theflawgrowthanalyses associatedwiththereactorcoolantlooppipingflaw toleranceevaluationarebasedon methods describedintheASME Boiler andPressureVesselCode,SectionXI, SubsectionIWB-3640.Theuseofan environmental factorof2appliedtothecrackgrowthrate determined for austenitic stainlesssteelinair,to accountfortheeffectof pressurized waterreactor(PWR) environment,isbasedonthe factor recommendedforthePWR environment in,"Evaluation ofFlawsin AusteniticSteelPiping
: 2. Confirm that the Kewaunee 7.4% uprating was considered in determining the design stresses for the flaw tolerance evaluation.
-SectionXITaskGroupforPipingFlawEvaluation," TransactionsofASME,JournalofPressureVessel Technology,Vol.108,Aug.1986,pp.352-366.
 
SerialNo.09-680 Docket No.50-305 Attachment 1/Page36of40RAI82.1.1(Alloy600 Inspections)
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 35 of 40
: 3. The details regarding flaw growth analyses, in particular, the technical basis for the choice of the environmental factor of 2 for fatigue crack growth rates in PWR environment.
DEK Response
: 1. The reactor coolant loop piping was supplied in accordance with material specification American Society for Testing and Materials (ASTM) A351, Grade CF-8M. This specification does not require the addition of niobium (or columbium) for Grade CF-8M steel. Additionally, the chemical compositions for the loop piping heats were reviewed and there was no indication of niobium (or columbium) content.
: 2. The Kewaunee 7.4% uprating was considered in determining the design stresses for the flaw tolerance evaluation.
: 3. The flaw growth analyses associated with the reactor coolant loop piping flaw tolerance evaluation are based on methods described in the ASME Boiler and Pressure Vessel Code, Section XI, Subsection IWB-3640.               The use of an environmental factor of 2 applied to the crack growth rate determined for austenitic stainless steel in air, to account for the effect of pressurized water reactor (PWR) environment, is based on the factor recommended for the PWR environment in, "Evaluation of Flaws in Austenitic Steel Piping - Section XI Task Group for Piping Flaw Evaluation," Transactions of ASME, Journal of Pressure Vessel Technology, Vol. 108, Aug. 1986, pp. 352-366.
 
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 36 of 40 RAI 82.1.1 (Alloy 600 Inspections)
Background/Issue:
Background/Issue:
This program is establishedtoensurethat augmented lSI of all alloy 600 componentsandweldsinthereactor coolantsystemat PWR-designed lightwaterreactorswillcontinuetobe performed per the latest NRC requirements and guidance.On September10,2008,inVolume 73 Number 176 oftheFederalRegister,theNRC published afinalruleinvoking severalrequirementsto addressthisissue.TheNRC mandatedtheuse of ASMECodeCaseN-729-1, as conditionedbytheNRC,toestablishnewrequirementsforlongterminspection of reactor pressure vessel upperheads.Thisaction,once implemented by a licensee, withdrew the requirements of the First Revised NRC Order EA-03-009, dated February 20,2004,fromthatlicensee.TheNRCalso mandatedtheuse of ASMECodeCaseN-722, as conditionedbytheNRC,toestablishlongterminspection requirementsforthefollowing componentsiftheycontain the primary water stress-corrosion cracking (PWSCC)susceptible materials designated Alloys 600/182/82; Reactor Vessel ReactorPressureVesselBottom Mounted NozzlesHotLeg Nozzle-to-Pipe ConnectionsColdLeg Nozzle-to-Pipe Connections Instrument Connections Steam GeneratorsHotLeg Nozzle-to-Pipe ConnectionsColdLeg Nozzle-to-Pipe Connections Bottom ChannelHeadDrainTubePenetrationPrimarySideHotLeg Instrumentation ConnectionsPrimarySideColdLeg Instrumentation Connections Pressurizer Heater Penetrations Spray Nozzle-to-Pipe Connections Safety and Relief Nozzle-to-Pipe Connections Surge Nozzle-to-Pipe Connections Instrument Connections Drain Nozzle-to-Pipe Connections PipingHotLeg Inslfument ConnectionsColdLeg Instrument ConnectionsHotLegFullPenetrationWeldsColdLegFullPenetrationWelds SerialNo.09-680DocketNo.50-305 Attachment1/Page37of40 On October 22,2008,theNRCissued Regulatory Issue Summary2008-25,whichstatedthe regulatoryapproachfor addressing PWSCC of dissimilar metal buttweldsin PWR primary coolantsystempiping.Thisapproachwas established in conjunction with the mandated inspections of ASMECodeCaseN-722, as conditionedbytheNRC.In2005,an industrygroup,theMaterials ReliabilityProgram(MRP) issued industry mandated guidelinesforthe examination of dissimilar metal buttweldsthrough a report designated MRP-139.Industryhasbeen implementing this inspection guideline andmitigatingweldstoaddressPWSCC.TheNRC staff has reviewed the MRP-139 guidelines and additionalMRPinterim guidanceletters.TheNRC staffbelievesthat MRP-139 andtheMRPinterim guidanceletters,withthe exception ofthereinspectionintervalfor unmitigated pressurizer dissimilar metal buttweldsthathavebeen previously addressedbycertain plant specific Confirmatory Action Letters, provide adequate protection of public health and safety for addressingPWSCCin buttweldsforthe near term pending incorporationbyreferenceinto10CFR50.55a of an ASMECodeCase containing comprehensiveinspectionrequirements.TheNRC staff is monitoring the industry's MRP-139 inspections and operating experience andwillusethisinformationtodetermineif any additional regulatoryactionsarenecessary.
This program is established to ensure that augmented lSI of all alloy 600 components and welds in the reactor coolant system at PWR-designed light water reactors will continue to be performed per the latest NRC requirements and guidance.
On January 26, 2009, ASME Boiler andPressureVesselCode publishedCodeCase770,"AlternativeExamination Requirements and Acceptance StandardsforClass1PWRPiping andVesselNozzleButtWelds FabricatedwithUNSN06082orUNSW86182WeldFiller MaterialWithorWithout Application of Listed Mitigation Activities."Itistheintention oftheNRCtoincorporatethe requirements of ASMECodeCase770into10CFR50.55a, as conditionedbytheNRC,inthe latest rulemaking activity toupdate10CFR50.55awhichis expectedtobe completed by December 2010.Request: Basedontheseactions,theNRCfindsthatthe AMPrequirements,toensureeffective augmented inservice inspections (lSI)of all alloy 600 based components andweldsinthereactor coolantsystemat PWR-designed light water reactors, needtobe updated to state compliance with current regulatory requirements of10CFR50.55a.
On September 10, 2008, in Volume 73 Number 176 of the Federal Register, the NRC published a final rule invoking several requirements to address this issue. The NRC mandated the use of ASME Code Case N-729-1, as conditioned by the NRC, to establish new requirements for long term inspection of reactor pressure vessel upper heads. This action, once implemented by a licensee, withdrew the requirements of the First Revised NRC Order EA-03-009, dated February 20,2004, from that licensee. The NRC also mandated the use of ASME Code Case N-722, as conditioned by the NRC, to establish long term inspection requirements for the following components if they contain the primary water stress-corrosion cracking (PWSCC) susceptible materials designated Alloys 600/182/82; Reactor Vessel Reactor Pressure Vessel Bottom Mounted Nozzles Hot Leg Nozzle-to-Pipe Connections Cold Leg Nozzle-to-Pipe Connections Instrument Connections Steam Generators Hot Leg Nozzle-to-Pipe Connections Cold Leg Nozzle-to-Pipe Connections Bottom Channel Head Drain Tube Penetration Primary Side Hot Leg Instrumentation Connections Primary Side Cold Leg Instrumentation Connections Pressurizer Heater Penetrations Spray Nozzle-to-Pipe Connections Safety and Relief Nozzle-to-Pipe Connections Surge Nozzle-to-Pipe Connections Instrument Connections Drain Nozzle-to-Pipe Connections Piping Hot Leg Inslfument Connections Cold Leg Instrument Connections Hot Leg Full Penetration Welds Cold Leg Full Penetration Welds
DEK ResponseLRASectionB2.1.1 identifiesalloftheAlloy600basemetalandAlloy82/182 dissimilarmetalwelds,andAlloy690basemetalandAlloy52/152 dissimilarmetalwelds,managedbytheAlloy600 Inspectionsprogram.The differencebetweenthescopeoftheAlloy600 Inspectionsprogramandthelistof potential locationsinRAIB2.1.1 Background/Issueisdueto Kewaunee plant-specificdesignand materials differences.TheAlloy600 Inspectionsprogramhasbeenupdatedtobe consistentwiththeregulatoryand industry initiatives for managing PWSCC susceptible materials designated Alloys 600/182/82.Thetablebelow identifiesthecurrent inspection
 
: bases, SerialNo.09-680DocketNo.50-305 Attachment1/Page38of40InadditiontotheASMEBoilerandPressureVesselCode,SectionXI,requirements,thatareimplementedforeachofthelocationsincludedintheprogram.
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 37 of 40 On October 22, 2008, the NRC issued Regulatory Issue Summary 2008-25, which stated the regulatory approach for addressing PWSCC of dissimilar metal butt welds in PWR primary coolant system piping. This approach was established in conjunction with the mandated inspections of ASME Code Case N-722, as conditioned by the NRC. In 2005, an industry group, the Materials Reliability Program (MRP) issued industry mandated guidelines for the examination of dissimilar metal butt welds through a report designated MRP-139. Industry has been implementing this inspection guideline and mitigating welds to address PWSCC. The NRC staff has reviewed the MRP-139 guidelines and additional MRP interim guidance letters. The NRC staff believes that MRP-139 and the MRP interim guidance letters, with the exception of the reinspection interval for unmitigated pressurizer dissimilar metal butt welds that have been previously addressed by certain plant specific Confirmatory Action Letters, provide adequate protection of public health and safety for addressing PWSCC in butt welds for the near term pending incorporation by reference into 10 CFR 50.55a of an ASME Code Case containing comprehensive inspection requirements. The NRC staff is monitoring the industry's MRP-139 inspections and operating experience and will use this information to determine if any additional regulatory actions are necessary.
, Locations Additional Inspection Bases IReactorVesselclosurehead penetrations(controlroddrive mechanisms, reactorCodeCaseN-729-1vessellevel instrumentsystem,andheadvent)andassociatedJ-grooveweldsReactorVesselbottomhead instrument tubeCodeCaseN-722 penetrationsandassociatedJ-grooveweldsReactorVesselsafetyinjectionnozzles MRP-139butteringweldReactorVesselcoresupportguidelug/weld None Steam GeneratorprimarynozzlessafeCodeCaseN-722 end/buttering MRP-139AsnotedinRAIB2.1.1 Background/Issue,CodeCaseN-770wasnotissueduntilJanuary2009.Thiscodecasehasnotyetbeen incorporatedintotheAlloy600 Inspectionsprogram,but,asrequired,willbeincorporatedintotheprogramoncethecodecasehasbeenincorporatedinto10CFR50.55a.TheAlloy600Inspectionsprogramaugmentedinservice inspectionsofAlloy 600-based componentsandweldsintheReactorCoolantSystemhavebeenupdatedtobein compliancewiththecurrentregulatory requirementsof10CFR50.55a.ThedescriptionoftheAlloy600 InspectionsprograminLRA AppendixA,USARSupplement,SectionA2.1.1willbechangedto:"ProgramDescription The Alloy 600 Inspectionsprogramisa plant-specificprogramthatconsistsoftheapplicabletenelementsasdescribedinAppendixAofNUREG-1800,"StandardReviewPlanforReviewofLicenseRenewal ApplicationsforNuclearPowerPlants."TheprogrammeetstheNUREG-1801expectationtohavea plant-specific programformanagingnickelalloy materialstocomplywiththeapplicableNRC publicationsandindustryguidelines.
On January 26, 2009, ASME Boiler and Pressure Vessel Code published Code Case N-770, "Alternative Examination Requirements and Acceptance Standards for Class 1 PWR Piping and Vessel Nozzle Butt Welds Fabricated with UNS N06082 or UNS W86182 Weld Filler Material With or Without Application of Listed Mitigation Activities."
The Alloy 600 InspectionsprogrammanagestheagingeffectsofprimarywaterstresscorrosioncrackinginAlloy600basemetalandAlloy82/182 dissimilar metalweldsandAlloy690basemetalandAlloy52/152 dissimilarmetalwelds.Theprogramperforms visual/baremetal,liquidpenetrant,eddycurrent,and ultrasonic examinationstodetectcrackingofthein-scope components in accordancewiththe SerialNo.09-680DocketNo.50-305 Attachment1/Page39of40 ASME Section XI Inservice Inspection, Subsections I we, I we, and IWD program,whichis consistentwiththe regulatory requirementsof10CFR50.55a."
It is the intention of the NRC to incorporate the requirements of ASME Code Case N-770 into 10 CFR 50.55a, as conditioned by the NRC, in the latest rulemaking activity to update 10 CFR 50.55a which is expected to be completed by December 2010.
SerialNo.09-680DocketNo.50-305 Attachment1/Page40of40RAI3.1.2.2.3.2.-1 Backqround:
Request:
The staff notedthatLRATable 3.1.2-1 subcomponents,"PrimaryNozzles(and cladding)" and"Upper, Intermediate and Lower Shell (and cladding)," credit the Reactor Vessel Surveillance program for managing loss of fracture toughness aging effect onthem.They represent GALL AMR Item IV.A2-17 for reactor pressurevessel(RPV) nozzles and GALL AMR Item IV.A2-24 for RPV shell, including beltline welds.Issue/Request: "Beltline welds,"whichare mentionedinGALL AMR Items IV.A2-17 and IV.A2-24 and SRP-LR Section 3.1.2.2.3.2,havenotbeen specified explicitly as part oftheLRATable3.1.2-1 subcomponents discussedabove.Pleaseresolvethis discrepancy because regardless of the selected methodology (CharpyV-notchor MasterCurve)for evaluation of material embrittlement, a Reactor Vessel Surveillance program is needed for managing loss of fracture toughness aging effect on relevant RPV materials, including welds.DEK Response The"Primary Nozzles (and cladding)"and"Upper, Intermediate and LowerShell(and cladding)" componentswhichcreditthe Reactor Vessel Surveillanceprogramfor managingtheagingeffectoflossof fracture toughnessduetoneutron irradiation embrittlement includes the associated componentweld(s)asrequiredby AppendixHto10CFRPart50,"ReactorVesselMaterial Surveillance Program Requirements."
Based on these actions, the NRC finds that the AMP requirements, to ensure effective augmented inservice inspections (lSI) of all alloy 600 based components and welds in the reactor coolant system at PWR-designed light water reactors, need to be updated to state compliance with current regulatory requirements of 10 CFR 50.55a.
SerialNo.09-680 Docket No.50-305 ATTACHMENT 2 REVISED RESPONSES FOR RAls2.3.3.18-1AND 82.1.14-3 (Replaces original responses in their entirety)KEWAUNEE POWER STATIONDOMINIONENERGY KEWAUNEE, INC.
DEK Response LRA Section B2.1.1 identifies all of the Alloy 600 base metal and Alloy 82/182 dissimilar metal welds, and Alloy 690 base metal and Alloy 52/152 dissimilar metal welds, managed by the Alloy 600 Inspections program. The difference between the scope of the Alloy 600 Inspections program and the list of potential locations in RAI B2.1.1 Background/Issue is due to Kewaunee plant-specific design and materials differences.
SerialNo.09-680DocketNo.50-305 Attachment 2/Page1of6 RAI2.3.3.18-1 BackgroundForKPS,the staff reviewedtheLRA;drawings;updated safety analysisreport,Sections 7.7.5, 8.2.2, 9.6.1, and Table 8.2-1;andthefollowingfire protection current licensingbasisdocumentslistedintheKPS OperatingLicenseCondition 2.C(3): SafetyEvaluationReports dated November 25, 1977, December 12, 1978, and supplementissuedon February 13, 1981.Issue The staff has identifiedthatfire protection systems and components discussedinthefollowingsectionshavebeen excludedfromthescope oflicenserenewal andanAMR.Thesesystems and componentswerenot includedinthelicense renewal boundaries and appeartohavefire protection intended functions required for compliancewithTitle10oftheCode of Federal Regulations(CFR)50.48,"Fire protection," as stated in10 CFR 54.4.Therefore,in ordertocompleteourreview,the staffrequiresresponsestothefollowingRAls:
The Alloy 600 Inspections program has been updated to be consistent with the regulatory and industry initiatives for managing PWSCC susceptible materials designated Alloys 600/182/82. The table below identifies the current inspection bases,
RequestTheLRAdrawing LRM-202-3 showfirehose connectionsatlocationsF9,F10,F11,G9, G10, and G11 as out ofscope(i.e.,not coloredinbrown).The staffrequeststhatthe applicant verify whether the abovefirehose connectionsareinthescope of licenserenewalin accordance with 10CFR54.4(a) and subjecttoan AMR in accordance with10CFR 54.21 (a)(1).Ifthesehose connections are excludedfromthescope of licenserenewalandnot subjecttoanAMR,the staffrequeststhatthe applicant provide justificationfortheexclusion.
 
Original DEK Response These non-safety-relatedfirehose connectionsshownat locationsF-9,F-10,F-11,G-9,G-10,andG-11onlicenserenewaldrawing LRM-202-3areusedonlyfornon-firepurposes(e.g.stationservices)anddonotperformalicenserenewal intended function.Additionally,thesehose connectionsarenotcreditedasseismic anchorsandLRNotes6and7onlicenserenewaldrawing LRM-202-3indicatewhytheservicewaterlinesassociatedwiththehose connectionsareomittedfromthescopeoflicenserenewalfor spatial considerations under10CFR54.4(a)(2).RevisedDEK ResponseThehose connectionsshownatlocationsF-9,F-10,F-11,G-9,G-10,andG-11onlicenserenewaldrawing LRM-202-3 are connectionsthatcanbeusedforgeneralplant SerialNo.09-680DocketNo.50-305 Attachment 2/Page2of6service.Thesehose connectionsareonlyusedfornon-firepurposes(e.g.stationservices)anddonotperformalicenserenewalintendedfunction.Additionally,these hose connectionsarenotcreditedasseismicanchorsandLRNotes6and7onlicenserenewaldrawingLRM-202-3indicatewhytheservicewaterlinesassociatedwiththe hose connectionsareomittedfromthescopeoflicenserenewalforspatial considerationsunder10CFR54.4(a)(2).FireHoseStationsthatareapartoftheService Water(SW)System,suchastheoneshownatlocation 8-6onlicenserenewaldrawingLRM-202-3,aredesignatedasFireHoseStationsandhavebeenincludedwithinthescopeoflicenserenewalfor10CFR 54.4(a)(3).
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 38 of 40 In addition to the ASME Boiler and Pressure Vessel Code, Section XI, requirements, that are implemented for each of the locations included in the program.
SerialNo.09-680DocketNo.50-305 Attachment 2/Page3of6 RAI82.1.14-3 BackgroundInException
  ,
#5 ofLRASectionB2.1.14,the applicantstatesthatKPSdoesnot perform multi-level sampling ofthefueloil day tanks.Instead a one-gallonsampleistakenfromthebottom ofthetankon a monthlybasisto allow for avisualinspectionforthe presence of water and sediment.IssueTheLRAdidnotprovidethe justification and the thresholdlcriteriathatwillbeusedforthevisualinspectionofthe one-gallon samplestakenfromthedaytankson a monthly basis.Request*Please provide a justification that avisualinspection ofthissampleis sufficientlieu of a laboratory analysis ofthesample as described in ASTM 04057.Provide and justify the thresholdlcriteriathatwillbeusedforthisvisualinspection of the sample, clearly identifying when correctiveactionswillbetaken.
Locations                     Additional Inspection Bases I Reactor Vessel closure head penetrations
Clarify how a visualinspectioniscapableof quantifying the amount of water/sediment/particulatesthatisintheone-gallonsample offueloil.*Clarifyifthereissometype offilterorfiltrationthatexistsbetweentherespectivefueloilstoragetankandfueloildaytankthatwouldlimitthe amount of contaminants enteringthedaytank.*Clarify whetherthesamplethatistakenfromthefueloildaytanksis atruebottomsampleorisittakenfrom another type of configuration.
  ~ (control rod drive mechanisms, reactor        Code Case N-729-1 vessel level instrument system, and head vent) and associated J-groove welds Reactor Vessel bottom head instrument tube Code Case N-722 penetrations and associated J-groove welds Reactor Vessel safety injection nozzles MRP-139 buttering weld Reactor Vessel core support guide lug/weld     None Steam Generator primary nozzles safe          Code Case N-722 end/buttering                                   MRP-139 As noted in RAI B2.1.1 Background/Issue, Code Case N-770 was not issued until January 2009. This code case has not yet been incorporated into the Alloy 600 Inspections program, but, as required, will be incorporated into the program once the code case has been incorporated into 10 CFR 50.55a.
Ifitisnot a true bottomsamplepleaseclarifythis other type of configuration and justifythatthereisnot a needtoremovethe accumulated water/sediment/contaminationfromthetankbottomthatisnotflushedoutduringthe monthly removal of the one-gallon sample.OriginalDEK ResponseLaboratorytestingofthe emergency diesel generators(EDG)andtechnicalsupportdiesel(TSC)daytanksfueloilwillbepertormed consistentwiththe quarterlysurveillancefrequencyforthefueloilstoragetanksandthe acceptance criteriarequirementsspecifiedinASTM 04057.Multi-leveltestingofthedaytanksisnotwarrantedduetotherelativelysmallvolumeofthedaytanksandthehigh turnover offueloilduetoperiodictesting.
The Alloy 600 Inspections program augmented inservice inspections of Alloy 600-based components and welds in the Reactor Coolant System have been updated to be in compliance with the current regulatory requirements of 10 CFR 50.55a.
SerialNo.09-680DocketNo.50-305 Attachment 2/Page4of6ThesamplepointsfortheEOGandTSCdaytankstapoffthesupplylinestothediesels,sothesamplesare representativeofwhatisbeingdrawnorusedbythediesel.TheEOGfueloildaytankshaveariserthreeinchesfromthebottomofthetank,whiletheTSCOGdaytankprovidesforatruebottomsample.Thereisnotypeoffiltrationlocatedbetweentherespectivefueloilstoragetanksandfueloildaytanks.Asaresultofthis commitmentfordaytanksamplingandlaboratoryanalysis,theLRAAppendix8,Section 82.1.14 is supplementedbytheremovalofException5.AsstatedintheresponsetoRAI 82.1.15-1,aone-timeinspectionwillbeperformedonthefueloildaytankspriortotheperiodofextendedoperation.The quarterly laboratoryanalysiscombinedwitha confirmatoryone-timeinspectionprovides assurancethattheeffectsofagingwillbe adequatelymanagedthroughtheperiodofextendedoperation.Thefollowing commitmentwillbeaddedtoLRAAppendixA,USAR Supplement, TableA6.0-1: Item Commitment Source Schedule 30 Quarterly laboratoryFuelOil ChemistryPriortothePeriodoftestingofthe EOGExtendedOperationandTSCDGdaytankfueloilsampleswillbeperformed.The testing andacceptancecriteriawillbe consistent withthatspecifiedASTM 04057RevisedDEK ResponseLaboratorytestingoffueloilforwater,sediment,and particulateswillbeperformedontheemergencydiesel generators(EDG)andtechnicalsupport center(TSC)diesel generatordaytanks,consistentwiththequarterly surveillance frequencyforthefueloilstoragetanks.Theacceptancecriteriaforwaterandsedimentwillbe consistentwiththerequirementsspecifiedinASTM 0975-06b.The acceptancecriteriafor particulates willbeconsistentwithASTM 06217.Multi-leveltestingofthedaytanksisnotwarrantedduetotherelativelysmallvolumeofthedaytanksandthehigh turnoveroffueloilduetoperiodictesting.Thedaytankvolumeand turnoverratearediscussedintheOEKResponsetoRAI 82.1.14-2providedbyletterdatedAugust17,2009[ADAMSAccessionNo.ML092320093].ThesamplepointsfortheEDGandTSCdaytankstapoffthesupplylinestothediesels,sothesamplesare representativeofwhatisbeingdrawnorusedbythediesel.TheEOGfueloildaytankshaveariserthreeinchesfromthebottomofthetank,while SerialNo.09-680DocketNo.50-305 Attachment 2/Page5of6theTSCDGdaytankprovidesforatruebottomsample.Thereisnofiltrationlocatedbetweentherespectivefueloilstoragetanksandfueloildaytanks.Asaresultofthis commitmentfordaytanksamplingand laboratoryanalysis,Exception5oftheLRASection82.1.14,FuelOilChemistry,isreplacedwiththefollowing: "Exception5:Diesel GeneratorDayTankFuelOilSamplingTheFuelOilChemistryprogramprovidesformonthlyvisual inspectionsandwillbeenhancedtoprovideforquarterlylaboratoryanalysisoffueloilsamplesobtainedfromthebottomofthedaytanksinlieuoftakingmultilevelsamplesofthedaytanksasrecommendedbyNUREG-1801,SectionX1.M30.
The description of the Alloy 600 Inspections program in LRA Appendix A, USAR Supplement, Section A2.1.1 will be changed to:
Justification The Emergency Diesel GeneratorsFuelOilDayTanksandtheTechnical Support Center Diesel GeneratorFuelOilDay Tankaresuppliedbythediesel generatorfueloilstoragetanks.Eachdaytankhasan approximate one-gallonsampleoffuelremovedfromthetankbottomeachmonthtoallowforvisualinspectionandquarterlyanalysisforthepresenceofwaterandsediment.Samplingatthislocation,wherewaterand sedimentwouldaccumulate,providesforeffectiveremovalof contaminantsfromthedaytankcontentsandensuresthequalityofthefueloilbeingsuppliedtothedieselgenerators.Therelativelysmallvolumeofthedaytanksandthehigh turnoveroffueloilsupportthe justificationfornotneedingtoperformmultileveltestingofthedaytanks.Inaddition,levelsamplesareobtainedfromthefueloilstoragetanksandanalyzed quarterlysuchthatingressof contaminantstothedaytanksisnotexpected.Therefore,theintentof NUREG-1801,SectionXI.M30,thatthequalityofthefueloilbemonitoredandmaintainedismetforthedaytanks.ProgramElementsAffected
    "Program Description The Alloy 600 Inspections program is a plant-specific program that consists of the applicable ten elements as described in Appendix A of NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants."
*Element 4: Detection of Aging EffectsThefrequentsamplingofthefueloildaytanks,combinedwiththemulti-levelsamplingofthediesel generatorfueloilstoragetanks,ensuresthatwaterand sedimentwillnot accumulatetoa significantextentinthedaytanks.Alongwithvisualinspectionand quarterlyanalysisofthefueloilforcontaminants,thegallonsampleoffuelthatisdrainedeachmonthfromthedaytank effectively removes contaminantsthatmayresultinagingeffectsofconcern,thereforemeetingtheintentofNUREG-1801,SectionXI.M30."AsstatedintheresponsetoRAI82.1.15-1providedinletterdatedAugust17,2009[ADAMSAccessionNo.
The program meets the NUREG-1801 expectation to have a plant-specific program for managing nickel alloy materials to comply with the applicable NRC publications and industry guidelines.
ML092320093],aone-timeinspectionwillbeperformedonthefueloildaytankspriortotheperiodofextendedoperation.Thequarterly laboratoryanalysiscombinedwitha confirmatoryone-timeinspectionprovides assurancethattheeffectsofagingwillbe adequatelymanagedthroughtheperiodofextendedoperation.
The Alloy 600 Inspections program manages the aging effects of primary water stress corrosion cracking in Alloy 600 base metal and Alloy 82/182 dissimilar metal welds and Alloy 690 base metal and Alloy 52/152 dissimilar metal welds. The program performs visual/bare metal, liquid penetrant, eddy current, and ultrasonic examinations to detect cracking of the in-scope components in accordance with the
SerialNo.09-680DocketNo.50-305 Attachment 2/Page6of6Thefollowing commitmentwillbeaddedtoLRAAppendixA,USAR Supplement, Table A6.0-1: Item Commitment Source Schedule 30 Quarterly laboratorytestingoffueloil samples forFuelOil ChemistryPriortothePeriodof water, sediment and particulateswillbe performed Extended Operationonthe Emergency Diesel Generators and Technical Support Center Diesel Generator day tank.Thetesting acceptancecriteriawillbe consistentwiththe requirements specified inASTMD975-06bforwaterand sediment andASTMD6217for particulates.
 
SerialNo.09-680 Docket No.50-305 ATTACHMENT 3 ADDITIONAL EXCEPTIONS FOR COMPRESSED AIR MONITORING PROGRAM KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 39 of 40 ASME Section XI Inservice Inspection, Subsections I we, I we, and IWD program, which is consistent with the regulatory requirements of 10 CFR 50.55a."
SerialNo.09-680DocketNo.50-305 Attachment 3/Page1of2 Compressed Air Monitoring Program Supplemental InformationDuringtheNRCRegionIIILicenseRenewalInspection,itwasidentifiedthatthetwodeviationsfromtheNUREG-1801,SectionXI.M24,"CompressedAirMonitoring"aging managementprogram(AMP)identifiedinthebasis documentforthe Compressed Air Monitoringprogramhadnotbeenincludedas exceptionsintheLRASection82.1.9, CompressedAirMonitoring,programdescription.Toclarifythesedeviations,thefollowing exceptionstotheNUREG-1801,SectionXI.M24AMPareidentifiedforthe CompressedAirMonitoringprogram:
 
Exception 2: CompressedAirSystemSampling LocationsTheStationand InstrumentAirSystemandthe Emergency Diesel Generatorairstart subsystemsarenotsampledatvariouslocationsas recommendedbyNUREG-1801,SectionXI.M24.
Serial No. 09-680 Docket No. 50-305 Attachment 1/Page 40 of 40 RAI 3.1.2.2.3.2.-1 Backqround:
JustificationThesamplepointfortheStationand InstrumentAirSystemis downstream ofthesystemdryertower.ThesamplepointsfortheEmergencyDiesel Generatorairstart subsystems are downstreamofthedryerforeach subsystem.Sincethesystemsarenormallypressurized,theonlysourcefor contaminatesormoistureintothesystemwouldbeviatherespectivecompressors.Therefore,measuringthequalityoftheairasitentersthesystemprovidesanaccuraterepresentationofthequalityoftheairinthesystems.ProgramElementsAffected
The staff noted that LRA Table 3.1.2-1 subcomponents, "Primary Nozzles (and cladding)" and "Upper, Intermediate and Lower Shell (and cladding)," credit the Reactor Vessel Surveillance program for managing loss of fracture toughness aging effect on them. They represent GALL AMR Item IV.A2-17 for reactor pressure vessel (RPV) nozzles and GALL AMR Item IV.A2-24 for RPV shell, including beltline welds.
*Element 1: Scope of ProgramMonitoringthe compressedairasitentersthesystemprovidesanaccuraterepresentationofthequalityoftheairtoensurethatthe compressed airsystemscanperformtheirintendedfunction.
Issue/Request:
Exception3:SamplingResultsTrendingThesampledatafortheStationandInstrumentAirSystemandthe Emergency Diesel Generatorairstart subsystemsarenottrendedasrecommendedbyNUREG-1801,SectionXI.M24.
"Beltline welds," which are mentioned in GALL AMR Items IV.A2-17 and IV.A2-24 and SRP-LR Section 3. 1.2.2.3.2, have not been specified explicitly as part of the LRA Table
Justification Specific chemistry control parameterlimitshavebeen establishedfortheStationandInstrumentAirSystemandthe Emergency Diesel Generator airstartsubsystems.Theselimitswere establishedbasedon ANSI/ISA-7.0.01-SerialNo.09-680DocketNo.50-305Attachment3/Page2of21996tosupportproperoperationofthecomponentssuppliedwithcompressedair.Measuredchemistryparametersarecomparedtothesecontrolparametersandactionistakentorestoretheparameterswithinspecificationifoutofspecificationconditionsareidentified.Maintainingthecompressedairsystemairqualityinaccordancewith ANSI/ISA-7.0.01-1996providessufficientmargintoensurecontinuedsystemfunction.Datatrendingofthecontrolparameterresultswouldnotprovideinformationusefulforagingmanagement.ChemistryproceduresrequirethatoutofspecificationconditionsaredocumentedintheCorrectiveAction Program.ProgramElementsAffected
: 3. 1.2-1 subcomponents discussed above. Please resolve this discrepancy because regardless of the selected methodology (Charpy V-notch or Master Curve) for evaluation of material embrittlement, a Reactor Vessel Surveillance program is needed for managing loss of fracture toughness aging effect on relevant RPV materials, including welds.
*Element 5: Monitoring and TrendingMaintainingthecompressedairsystemairqualityinaccordancewith ANSI/ISA-7.0.01-1996ensuresthatthecompressedairsystemscanperformtheirintendedfunction.}}
DEK Response The "Primary Nozzles (and cladding)" and "Upper, Intermediate and Lower Shell (and cladding)" components which credit the Reactor Vessel Surveillance program for managing the aging effect of loss of fracture toughness due to neutron irradiation embrittlement includes the associated component weld(s) as required by Appendix H to 10 CFR Part 50, "Reactor Vessel Material Surveillance Program Requirements."
 
Serial No. 09-680 Docket No. 50-305 ATTACHMENT 2 REVISED RESPONSES FOR RAls 2.3.3.18-1 AND 82.1.14-3 (Replaces original responses in their entirety)
KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.
 
Serial No. 09-680 Docket No. 50-305 Attachment 2/Page 1 of 6 RAI2.3.3.18-1
 
===Background===
For KPS, the staff reviewed the LRA; drawings; updated safety analysis report, Sections 7.7.5, 8.2.2, 9.6.1, and Table 8.2-1; and the following fire protection current licensing basis documents listed in the KPS Operating License Condition 2.C(3):
Safety Evaluation Reports dated November 25, 1977, December 12, 1978, and supplement issued on February 13, 1981.
Issue The staff has identified that fire protection systems and components discussed in the following sections have been excluded from the scope of license renewal and an AMR.
These systems and components were not included in the license renewal boundaries and appear to have fire protection intended functions required for compliance with Title 10 of the Code of Federal Regulations (CFR) 50.48, "Fire protection," as stated in 10 CFR 54.4. Therefore, in order to complete our review, the staff requires responses to the following RAls:
Request The LRA drawing LRM-202-3 show fire hose connections at locations F9, F10, F11, G9, G10, and G11 as out of scope (i.e., not colored in brown). The staff requests that the applicant verify whether the above fire hose connections are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21 (a)(1). If these hose connections are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
Original DEK Response These non-safety-related fire hose connections shown at locations F-9, F-10, F-11, G-9, G-10, and G-11 on license renewal drawing LRM-202-3 are used only for non-fire purposes (e.g. station services) and do not perform a license renewal intended function.
Additionally, these hose connections are not credited as seismic anchors and LR Notes 6 and 7 on license renewal drawing LRM-202-3 indicate why the service water lines associated with the hose connections are omitted from the scope of license renewal for spatial considerations under 10 CFR 54.4(a)(2).
Revised DEK Response The hose connections shown at locations F-9, F-10, F-11, G-9, G-10, and G-11 on license renewal drawing LRM-202-3 are connections that can be used for general plant
 
Serial No. 09-680 Docket No. 50-305 Attachment 2/Page 2 of 6 service. These hose connections are only used for non-fire purposes (e.g. station services) and do not perform a license renewal intended function. Additionally, these hose connections are not credited as seismic anchors and LR Notes 6 and 7 on license renewal drawing LRM-202-3 indicate why the service water lines associated with the hose connections are omitted from the scope of license renewal for spatial considerations under 10 CFR 54.4(a)(2).
Fire Hose Stations that are a part of the Service Water (SW) System, such as the one shown at location 8-6 on license renewal drawing LRM-202-3, are designated as Fire Hose Stations and have been included within the scope of license renewal for 10 CFR 54.4(a)(3).
 
Serial No. 09-680 Docket No. 50-305 Attachment 2/Page 3 of 6 RAI82.1.14-3
 
===Background===
In Exception #5 of LRA Section B2.1.14, the applicant states that KPS does not perform multi-level sampling of the fuel oil day tanks. Instead a one-gallon sample is taken from the bottom of the tank on a monthly basis to allow for a visual inspection for the presence of water and sediment.
Issue The LRA did not provide the justification and the thresholdlcriteria that will be used for the visual inspection of the one-gallon samples taken from the day tanks on a monthly basis.
Request
* Please provide a justification that a visual inspection of this sample is sufficient in-lieu of a laboratory analysis of the sample as described in ASTM 04057. Provide and justify the thresholdlcriteria that will be used for this visual inspection of the sample, clearly identifying when corrective actions will be taken. Clarify how a visual inspection is capable of quantifying the amount of water/sediment/particulates that is in the one-gallon sample of fuel oil.
* Clarify if there is some type of filter or filtration that exists between the respective fuel oil storage tank and fuel oil day tank that would limit the amount of contaminants entering the day tank.
* Clarify whether the sample that is taken from the fuel oil day tanks is a true bottom sample or is it taken from another type of configuration. If it is not a true bottom sample please clarify this other type of configuration and justify that there is not a need to remove the accumulated water/sediment/contamination from the tank bottom that is not flushed out during the monthly removal of the one-gallon sample.
Original DEK Response Laboratory testing of the emergency diesel generators (EDG) and technical support diesel (TSC) day tanks fuel oil will be pertormed consistent with the quarterly surveillance frequency for the fuel oil storage tanks and the acceptance criteria requirements specified in ASTM 04057. Multi-level testing of the day tanks is not warranted due to the relatively small volume of the day tanks and the high turnover of fuel oil due to periodic testing.
 
Serial No. 09-680 Docket No. 50-305 Attachment 2/Page 4 of 6 The sample points for the EOG and TSC day tanks tap off the supply lines to the diesels, so the samples are representative of what is being drawn or used by the diesel.
The EOG fuel oil day tanks have a riser three inches from the bottom of the tank, while the TSC OG day tank provides for a true bottom sample. There is no type of filtration located between the respective fuel oil storage tanks and fuel oil day tanks.
As a result of this commitment for day tank sampling and laboratory analysis, the LRA Appendix 8, Section 82.1.14 is supplemented by the removal of Exception 5.
As stated in the response to RAI 82.1.15-1, a one-time inspection will be performed on the fuel oil day tanks prior to the period of extended operation. The quarterly laboratory analysis combined with a confirmatory one-time inspection provides assurance that the effects of aging will be adequately managed through the period of extended operation.
The following commitment will be added to LRA Appendix A, USAR Supplement, Table A6.0-1 :
Item                 Commitment               Source               Schedule 30                   Quarterly laboratory Fuel Oil Chemistry      Prior to the Period of testing of the EOG                            Extended Operation and TSC DG day tank fuel oil samples will be performed.      The testing            and acceptance      criteria will be consistent with that specified ASTM 04057 Revised DEK Response Laboratory testing of fuel oil for water, sediment, and particulates will be performed on the emergency diesel generators (EDG) and technical support center (TSC) diesel generator day tanks, consistent with the quarterly surveillance frequency for the fuel oil storage tanks. The acceptance criteria for water and sediment will be consistent with the requirements specified in ASTM 0975-06b. The acceptance criteria for particulates will be consistent with ASTM 06217. Multi-level testing of the day tanks is not warranted due to the relatively small volume of the day tanks and the high turnover of fuel oil due to periodic testing. The day tank volume and turnover rate are discussed in the OEK Response to RAI 82.1.14-2 provided by letter dated August 17, 2009 [ADAMS Accession No. ML092320093].
The sample points for the EDG and TSC day tanks tap off the supply lines to the diesels, so the samples are representative of what is being drawn or used by the diesel.
The EOG fuel oil day tanks have a riser three inches from the bottom of the tank, while
 
Serial No. 09-680 Docket No. 50-305 Attachment 2/Page 5 of 6 the TSC DG day tank provides for a true bottom sample. There is no filtration located between the respective fuel oil storage tanks and fuel oil day tanks.
As a result of this commitment for day tank sampling and laboratory analysis, Exception 5 of the LRA Section 82.1.14, Fuel Oil Chemistry, is replaced with the following:
"Exception 5: Diesel Generator Day Tank Fuel Oil Sampling The Fuel Oil Chemistry program provides for monthly visual inspections and will be enhanced to provide for quarterly laboratory analysis of fuel oil samples obtained from the bottom of the day tanks in lieu of taking multilevel samples of the day tanks as recommended by NUREG-1801, Section X1.M30.
Justification The Emergency Diesel Generators Fuel Oil Day Tanks and the Technical Support Center Diesel Generator Fuel Oil Day Tank are supplied by the diesel generator fuel oil storage tanks. Each day tank has an approximate one-gallon sample of fuel removed from the tank bottom each month to allow for visual inspection and quarterly analysis for the presence of water and sediment.
Sampling at this location, where water and sediment would accumulate, provides for effective removal of contaminants from the day tank contents and ensures the quality of the fuel oil being supplied to the diesel generators. The relatively small volume of the day tanks and the high turnover of fuel oil support the justification for not needing to perform multilevel testing of the day tanks. In addition, multi-level samples are obtained from the fuel oil storage tanks and analyzed quarterly such that ingress of contaminants to the day tanks is not expected.
Therefore, the intent of NUREG-1801, Section XI.M30, that the quality of the fuel oil be monitored and maintained is met for the day tanks.
Program Elements Affected
* Element 4: Detection of Aging Effects The frequent sampling of the fuel oil day tanks, combined with the multi-level sampling of the diesel generator fuel oil storage tanks, ensures that water and sediment will not accumulate to a significant extent in the day tanks. Along with visual inspection and quarterly analysis of the fuel oil for contaminants, the one-gallon sample of fuel that is drained each month from the day tank effectively removes contaminants that may result in aging effects of concern, therefore meeting the intent of NUREG-1801, Section XI.M30."
As stated in the response to RAI 82.1.15-1 provided in letter dated August 17, 2009
[ADAMS Accession No. ML092320093], a one-time inspection will be performed on the fuel oil day tanks prior to the period of extended operation. The quarterly laboratory analysis combined with a confirmatory one-time inspection provides assurance that the effects of aging will be adequately managed through the period of extended operation.
 
Serial No. 09-680 Docket No. 50-305 Attachment 2/Page 6 of 6 The following commitment will be added to LRA Appendix A, USAR Supplement, Table A6.0-1:
Item    Commitment                                          Source            Schedule 30      Quarterly laboratory testing of fuel oil samples for Fuel Oil Chemistry Prior to the Period of water, sediment and particulates will be performed                      Extended Operation on the Emergency Diesel Generators and Technical Support Center Diesel Generator day tank. The testing acceptance criteria will be consistent with the requirements specified in ASTM D975-06b for water and sediment and ASTM D6217 for particulates.
 
Serial No. 09-680 Docket No. 50-305 ATTACHMENT 3 ADDITIONAL EXCEPTIONS FOR COMPRESSED AIR MONITORING PROGRAM KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.
 
Serial No. 09-680 Docket No. 50-305 Attachment 3/Page 1 of 2 Compressed Air Monitoring Program Supplemental Information During the NRC Region III License Renewal Inspection, it was identified that the two deviations from the NUREG-1801, Section XI.M24, "Compressed Air Monitoring" aging management program (AMP) identified in the basis document for the Compressed Air Monitoring program had not been included as exceptions in the LRA Section 82.1.9, Compressed Air Monitoring, program description.
To clarify these deviations, the following exceptions to the NUREG-1801, Section XI.M24 AMP are identified for the Compressed Air Monitoring program:
Exception 2: Compressed Air System Sampling Locations The Station and Instrument Air System and the Emergency Diesel Generator air start subsystems are not sampled at various locations as recommended by NUREG-1801, Section XI.M24.
Justification The sample point for the Station and Instrument Air System is downstream of the system dryer tower. The sample points for the Emergency Diesel Generator air start subsystems are downstream of the dryer for each subsystem.
Since the systems are normally pressurized, the only source for contaminates or moisture into the system would be via the respective compressors.
Therefore, measuring the quality of the air as it enters the system provides an accurate representation of the quality of the air in the systems.
Program Elements Affected
* Element 1: Scope of Program Monitoring the compressed air as it enters the system provides an accurate representation of the quality of the air to ensure that the compressed air systems can perform their intended function.
Exception 3: Sampling Results Trending The sample data for the Station and Instrument Air System and the Emergency Diesel Generator air start subsystems are not trended as recommended by NUREG-1801, Section XI.M24.
Justification Specific chemistry control parameter limits have been established for the Station and Instrument Air System and the Emergency Diesel Generator air start subsystems. These limits were established based on ANSI/ISA-7.0.01-
 
Serial No. 09-680 Docket No. 50-305 Attachment 3/Page 2 of 2 1996 to support proper operation of the components supplied with compressed air. Measured chemistry parameters are compared to these control parameters and action is taken to restore the parameters within specification if out of specification conditions are identified.
Maintaining the compressed air system air quality in accordance with ANSI/ISA-7.0.01-1996 provides sufficient margin to ensure continued system function. Data trending of the control parameter results would not provide information useful for aging management. Chemistry procedures require that out of specification conditions are documented in the Corrective Action Program.
Program Elements Affected
* Element 5: Monitoring and Trending Maintaining the compressed air system air quality in accordance with ANSI/ISA-7.0.01-1996 ensures that the compressed air systems can perform their intended function.}}

Latest revision as of 01:27, 14 November 2019

Response to Request for Additional Information for Review of License Renewal Application - Aging Management Review Results
ML093170751
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 11/13/2009
From: Matthews W
Dominion Energy Kewaunee
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
09-680, FOIA/PA-2010-0209
Download: ML093170751 (55)


Text

I lominion Energy Kewaunee, Inc.

I)(i; l iorninion Boulevard, Glen Allen. VA 2>il! DOlllinio..**

November 13, 2009 United States Nuclear Regulatory Commission Serial No.: 09-680 Attention: Document Control Desk LR/DEA RO Washington, DC 20555-0001 Docket No.: 50-305 License No.: DPR-43 DOMINION ENERGY KEWAUNEE, INC.

KEWAUNEE POWER STATION RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE KEWAUNEE POWER STATION LICENSE RENEWAL APPLICATION-AGING MANAGEMENT REVIEW RESULTS By letter dated October 13, 2009 (Reference 1), the NRC provided a request for additional information regarding the aging management review results included in the license renewal application (LRA) for Kewaunee Power Station (KPS) (Reference 2).

The NRC staff indicated that responses to each request for additional information (RAls) are needed to complete the review of the KPS LRA. Attachment 1 to this letter provides the Dominion Energy Kewaunee Inc. (DEK) responses to each of the RAls submitted by the NRC staff in Reference 1.

DEK letters dated August 6, 2009 (Reference 3) and August 17, 2009 (Reference 4) provided responses to NRC RAls 2.3.3.18-1 and B2.1.14-3, respectively. DEK subsequently determined that clarifications to these RAI responses were needed.

Additionally, the revised response to RAI B2.1.14-3 includes the addition of Exception 5 which was previously identified for removal in the original response. Attachment 2 to this letter provides the necessary clarifications and replaces the original responses to RAls 2.3.3.18-1 and 82.1.14-3 in their entirety.

The on-site portion of the Region III License Renewal Inspection was conducted from August 17, 2009 through August 21, 2009 and August 31, 2009 through September 4, 2009. During this inspection, DEK indicated that two additional exceptions would be created for the Compressed Air Monitoring program. These exceptions are provided in .

Serial No.09-680 Docket No. 50-305 Page 2 of 4 Should you have any questions regarding this submittal, please contact Mr. Paul C.

Aitken at (804) 273-2818.

Very truly yours,

&./.£V¥~<

William R. Matthews Senior Vice President - Nuclear Operations COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledged before me, in and for the County and State aforesaid, today by William R. Matthews, who is Senior Vice President - Nuclear Operations of Dominion Energy Kewaunee, Inc. He has affirmed before me that he is duly authorized to execute and file the foregoing document on behalf of that Company, and that the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this 13 "[JIday ofY(Ot0nd1l"AJ ,2009. ,

My Commission Expires: . I;L beL' x: ,J-fvtu<

Notary Public

- VICKI L. HULL Notary Public ~

Commonwealth 140542 0' VIrginia ~

~

My Commission Expires May 31, 2010

-

Serial No.09-680 Docket No. 50-305 Page 3 of 4

References:

1. Letter from Samuel Hernandez (NRC) to David A. Heacock (DEK), "Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Review Results (TAC No. MD9408),"

dated October 13, 2009. [ADAMS Accession No. ML092390063]

2. Letter from D. A. Christian (DEK) to NRC, "Kewaunee Power Station Application for Renewed Operating License," dated August 12, 2008. [ADAMS Accession No.

ML082341020]

3. Letter from D. A. Christian (DEK) to NRC, "Response to Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Structures Scoping / Fire Protection," dated August 6, 2009. [ADAMS Accession No. ML092190757]
4. Letter from D. A. Christian (DEK) to NRC, "Response to Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Programs," dated August 17, 2009. [ADAMS Accession No. ML092320093]

Attachments:

1. Response to Request for Additional Information Regarding Aging Management Review Results
2. Revised Responses for RAls 2.3.3.18-1 and 82.1.14-3
3. Additional Exceptions for Compressed Air Monitoring Program Commitments made in this letter:
1. The Alloy 600 Inspections program in LRA Appendix A, USAR Supplement, Section A2.1.1, will be revised to change the Program Description consistent with the response to RAI 82.1.1. The revised Program Description is proposed to support approval of the renewed operating license, and may change during the NRC review period.
2. License Renewal Commitment 30, identified in LRA Table A6.0-1, will be revised consistent with the revised response to RAI 82.1.14-3 described in Attachment 3 to this letter. The revised commitment is proposed to support approval of the renewed operating license, and may change during the NRC review period.
3. Additional information will be added to LRA Appendix A, USAR Supplement, Sections A4.2.1 and A3.6, consistent with the response to RAI 4.2.1-1 regarding neutron fluence. The additional information is proposed to support approval of the renewed operating license, and may change during the NRC review period.

Serial No.09-680 Docket No. 50-305 Page 4 of 4 cc: U.S. Nuclear Regulatory Commission Regional Administrator, Region III 2443 Warrenville Road Suite 210 Lisle, IL 60532-4532 Mr. P. S. Tam, Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint, Mail Stop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738 Ms. V. Perin Environmental Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-11 F1 Washington, DC 20555-0001 Mr. Q. S. Hernandez License Renewal Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-11 F1 Washington, DC 20555-0001 NRC Senior Resident Inspector Kewaunee Power Station N490 Highway 42 Kewaunee, WI 54216 Public Service Commission of Wisconsin Electric Division P.O. Box 7854 Madison, WI 53707 David Hardtke Chairman - Town of Carlton E2334 Lakeshore Road Kewaunee, WI 54216

Serial No.09-680 Docket No. 50-305 ATTACHMENT 1 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING AGING MANAGEMENT REVIEW RESULTS KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 1 of 40 Request for Additional Information (RAI) 3.1.2.2.6 Reactor Vessel Internals

Background:

License Renewal Application (LRA) Table 3.1.2-2 references Generic Aging Lessons Learned (GALL) Aging Management Review (AMR) Item IV.B2-9 and lists loss of fracture toughness due to neutron irradiation embrittlement and void swelling (an aging mechanism discussed in LRA Section 3.1.2.2.6) as one of the aging mechanisms affecting the following RV internals: head & vessel alignment pins, rod cluster control assembly (RCCA) guide tube bolts, RCCA guide tube support pins, upper core plate alignment pins, upper fuel alignment pins, upper support column bolts, upper support plate assembly, upper core plate, and hold-down spring. However, GALL Table IV.B2 (Item IV.B2-9 and other items relevant to these RV internals) does not consider the above-mentioned aging mechanism applicable to these RV internals.

Request:

Please indicate if the listing of aging mechanisms (loss of fracture toughness due to neutron irradiation embrittlement and void swelling) for the above mentioned RV internals was prompted by plant-specific experience or if this was due to a conservative approach.

DEK Response The identification of loss of fracture toughness due to neutron irradiation embrittlement and void swelling for the head & vessel alignment pins, rod cluster control assembly (RCCA) guide tube bolts, RCCA guide tube support pins, upper core plate alignment pins, upper fuel alignment pins, upper support column bolts, upper support plate assembly, upper core plate, and hold-down spring was due to a conservative approach.

There is no plant-specific operating experience that indicates these aging mechanisms are actually occurring for these components.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 2 of 40 RAI3.5.2.3-1

Background:

In LRA Table 3.0-1, Raw Water has been defined as water that has, "not been demineralized or chemically treated to any significant extent, and includes intake water from Lake Michigan." Also the raw water includes treated water that leaks from plant systems into floor drains and sumps. LRA Tables 3.5.2-1 through 3.5.2-14 include several line items with the environment listed as raw water. These items have been assigned Standard Note H, which states, "aging effect not in NUREG-1801 for this component, material and environment combination."

Issue:

Raw water chemistry may be such that it can cause degradation for concrete, steel, and other material.

Reguest:

1. Explain the past and present raw water monitoring activities and discuss the results in terms of the aggressiveness of water.
2. If raw water is not monitored, what inspection/monitoring criteria of the Structures Monitoring Program are or will be followed to ensure that the effects of aging will be adequately managed so that the intended function(s) will be maintained consistent with the CLB for the period of extended operation.

DEK Response

1. Periodic monitoring of the raw intake water from Lake Michigan, which is a fresh water lake, is not presently being performed and has not been performed in the past.

However, the analysis of lake water samples taken in 1971, 2004, and 2006, indicated average readings of 8.18 for pH, 8.94 ppm for chlorides, and 22.63 ppm for sulfates. Also, a 2004 analysis of water samples taken from the two deep potable water wells located on site indicated average readings of 7.5 for pH, 34 ppm for chlorides, and 640 ppm for sulfates. Based on the above results, intake water from Lake Michigan and potable well water are considered non-aggressive to concrete or steel.

No past or present periodic monitoring activities have been performed for drains and sumps to identify chemicals considered aggressive to concrete or steel. However, water collected in floor drains and sumps is monitored for gamma, tritium, and suspended solids. Additionally, if a high sump level is detected in the Reactor Containment Vessel, the sump water may be tested for boron, conductivity, and pH to help determine the leakage source.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 3 of 40 The sources of water that leak from plant systems into floor drains and sumps is either from Lake Michigan, potable wells, or treated water systems. These are all considered non-aggressive to concrete and steel. Consequently, the sumps are not periodically monitored for aggressive constituents. Additionally, identified leaks do not continue for the extensive period of time required for degradation of concrete, steel, and other material to occur.

2. The ground water chemistry for inaccessible below grade concrete is periodically monitored in accordance with the Structures Monitoring Program (SMP). However, as stated above, raw water is considered non-aggressive and is therefore not periodically monitored. Furthermore, all structures or structural members within the scope of license renewal that are exposed to a raw water environment are accessible for visual inspection and the applicable aging effects are managed by the SMP, regardless of the composition of the raw water. Therefore, the effects of aging for in-scope structures or structural members exposed to raw water will be adequately managed so that the intended function(s) will be maintained consistent with the CLB for the period of extended operation.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 4 of 40 RAI 3.5.2.3-2

Background:

LRA Table 3.5.2-1 states that Structures Monitoring Program will be used for the aging management of the sumps inside the Reactor Containment Vessel. Also the applicant assigned industry Standard Note H which implies that the aging effect is not consistent with the GALL Report for this component, material, and environment combination.

Issue:

The environment is raw water which can be aggressive. The LRA does not have information about the raw water chemistry. According to the GALL Report, IWE is the applicable program for the Reactor Containment Vessel structures and components that form the containment pressure boundary. However; the applicant has credited Structures Monitoring Program for these items. Furthermore, the LRA Table items state corrosion as the aging effect of embedded steel and intended function to be SS (structural support).

Request:

1. Explain the past and present raw water monitoring activities and discuss the results in terms of the aggressiveness of raw water.
2. In case raw water is aggressive, what inspection/monitoring criteria are or will be implemented in the Structures Monitoring Program to ensure that the effects of aging will be adequately managed so that the intended function(s) for concrete and embedded steel will be maintained consistent with the CLB for the period of extended operation.
3. Explain the justification for not including the containment sump in the IWE Program.

Note that in the AMR line it is listed as PB (pressure boundary) and SS (structural support).

DEK Response

1. The information requested by this RAI is provided in the response to RAI 3.5.2.3-1, Request 1, included in this attachment.
2. As discussed in the response to RAI 3.5.2.3-1, Request 1, raw water at Kewaunee is considered non-aggressive. All in-scope structures or structural members exposed to a raw water environment are accessible for visual inspection and the applicable aging effects are managed with the Structures Monitoring Program, regardless of the composition of the raw water. Therefore, the intended function(s) for concrete and embedded steel will be maintained consistent with the CLB for the period of extended operation.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 5 of 40

3. Consistent with NUREG 1801,Section II, the IWE program is applicable to the Reactor Containment Vessel and its components such as penetrations, airlocks, and hatches, etc. The Structures Monitoring Program is used to monitor all the internal structures of the Reactor Containment Vessel including the sumps and common basemat. The pressure boundary function indicated in LRA Tables 2.4.1-1 and 3.5.2-1 for the Containment sump is considered a system function (water retention) and not a structural function. Specifically, the sump is not considered part of the Reactor Containment Vessel pressure boundary.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 6 of 40 RAI 3.5.2.3-3

Background:

Standard Note H has been assigned to several line items in LRA Tables 3.5.2-2 to 3.5.2-14. Standard Note H indicates that the "aging effect not in NUREG-1801 for this component, material and environment combination." According to the LRA Tables, increase in porosity and permeability, loss of strength/leaching of calcium hydroxide of concrete are noted in the environment air-outdoor. In normal conditions, leaching can occur when water passes through the concrete.

Issue:

The phenomenon of leaching of concrete in air-outdoor is not clearly described in the LRA.

Request:

Please describe the structures where leaching of calcium hydroxide is occurring in the environment of air. Also explain the possible reason(s) for such leaching.

DEK Response The 2007 Maintenance Rule Inspection results indicated minor leaching of concrete in an air-outdoor environment for the following structural members:

  • The main auxiliary transformer north and south concrete bay walls
  • The concrete masonry wall that forms the back bay wall of the reserve auxiliary transformer and Turbine Building exterior wall
  • The Screenhouse forebay exterior concrete wall In an air-outdoor environment, water from rain or melting snow that contains small concentrations of calcium ions can dissolve the calcium compounds found in concrete when it passes through cracks or inadequately prepared construction joints.

Efflorescence, a surface phenomenon consisting of salt deposits that have been leached from concrete, can also occur in an air-outdoor environment. Although efflorescence is an aesthetic issue rather than a structural problem, it does indicate that leaching is occurring.

NUREG-1801 indicates that leaching of calcium hydroxide occurs only in a flowing water environment. Leaching does occur more readily when structures are subjected to flowing water, ponding, or hydraulic pressure, which can occur with water control structures such as the Intake, Screenhouse, and Discharge structures. Therefore, since DEK has conservatively included leaching of calcium hydroxide as an aging effect/mechanism in an air-outdoor environment, Standard Note H was applied to

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 7 of 40 indicate that this aging effect is not in NUREG -1801 for this component, material and environment combination.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 8 of 40 RAI82.1.27-1 Background/Issue:

LRA Section B2.1.27, "Reactor Vessel Surveillance," states under Enhancement 1: 'The Reactor Vessel Surveillance program will be enhanced to include the applicable limitations on operating conditions to which the surveillance capsules were exposed (e.g., neutron flux, spectrum, irradiation temperature, etc.)."

Request:

Please provide details regarding these applicable limitations. Further, demonstrate that with this Enhancement the Reactor Vessel Surveillance program meet the acceptance criteria 2,3, and 6 that were listed in GALL Aging Management Program (AMP) XI.M31, "Reactor Vessel Surveillance."

DEK Response Enhancement 1 to the Reactor Vessel Surveillance program, described in LRA Section 82.1.27, provides a program enhancement to ensure that future changes in plant operating parameters or neutron flux due to power uprates or other conditions are evaluated to ensure that the parameter values used to project the effects of embrittlement to the end of the period of extended operation remain bounding for actual plant conditions.

This Reactor Vessel Surveillance program enhancement will ensure that:

  • Changes in plant parameters (e.g., operating temperature, neutron fluence) to which reactor vessel materials are exposed, are evaluated for the affect on the applicability of NRC Regulatory Guide 1.99, Revision 2, Radiation Embrittlement of Reactor Vessel Materials, Regulatory Position 1, as discussed in NUREG-1801,Section XI.M31 , Item 2.
  • Plant parameters (e.g., cold leg temperature, neutron fluence) remain within the bounds defined for the surveillance data used as input to the embrittlement evaluations, as discussed in NUREG-1801,Section XI.M31 , Item 3.
  • Reactor vessel exposure conditions (e.g., neutron flux, spectrum, irradiation temperature, etc.) are monitored to ensure that the actual exposure conditions remain consistent with those used to project the effects of embrittlement to the end of the period of extended operation, as discussed in NUREG-1801 ,Section XI.M31 , Item 6.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 9 of 40 RAI 4.2.2 Reactor Vessel Background/Issue:

The U.S. Nuclear Regulatory Commission's (NRC) reactor vessel integrity database (RVIO) does not contain information for the extended beltline materials reported in the LRA.

Request:

Please discuss the procedures used to determine the chemistry data, initial reference temperature (RTNDT), and margins for the extended beltline materials to demonstrate that there are consistent approaches for both beltline and extended beltline materials.

DEK Response Chemistry data, initial reference temperature (RT NOT), and margins for the extended beltline materials are provided in LRA Table 4.2-3, RTp Ts Results for Kewaunee Power Station Beltline and Extended Beltline Region Materials at EOLR (52. 1 EFPY). These extended beltline material parameters were determined as described below.

Chemistry Data In determining the copper (Cu) and nickel (Ni) weight percentages, the original Certification Material Test Reports (CMTRs) were reviewed to determine the measured values. In some cases, the CMTR may not have included a measured Cu or Ni weight percent. In those cases, the best-estimate value was determined based on the following guidance provided in Regulatory Guide 1.99, Revision 2, Radiation Embrittlement of Reactor Vessel Materials:

"If the best-estimate weight percent Cu and Ni values are not available, the upper limiting values given in the materials specifications to which the vessel was built may be used. If not available, conservative estimates (mean plus one standard deviation) based on generic data may be used if justification is provided. If there is no information available, 0.35 % copper and 1.0% nickel should be assumed."

Between the CMTRs and the guidance from Regulatory Guide 1.99, Revision 2 provided above, best-estimate Cu and Ni weight percentages were determined for the extended beltline materials.

Initial Reference Temperature The determination of fracture toughness of the ferritic materials used for reactor vessels is necessary to ensure that such components will behave in a non-brittle manner and that the probability of a rapidly propagating fracture will be minimized under operating, maintenance, and testing conditions and during anticipated operational occurrences. In most cases, the fracture toughness is characterized by its reference nil ductility temperature (RT NOT).

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 10 of 40 The fracture toughness properties of the ferritic material in the reactor vessel pressure boundary were determined, as required by 10 CFR 50, Appendix G, in accordance with the requirements in subsection NB-2331 of Section III of the ASME Boiler and Pressure Vessel Code. The initial RTNOT values were determined from drop-weight tests or Charpy test results in accordance with Branch Technical Position MTEB 5-2 ("Fracture Toughness Requirements") of the NRC Standard Review Plan (NUREG-0800), Section 5.3.2, Rev. 1 (1981), as summarized below:

  • T NOT shall be determined by means of drop-weight test.
  • T NOT is the RTNOT if at T NOT + 60°F, a Charpy test exhibits 50 ft-lbs of energy and 35 mils lateral expansion.
  • If not, then the temperature when this occurs must be determined using the minimum data points from all the Charpy tests on that material. This temperature shall be known as T 50/35 and RTNOT shall be T50/35 - 60°F. This assumes the Charpy tests were in the weak (transverse/axial) orientation.
  • If the Charpy tests are in the strong (longitudinal/tangential) orientation, then T50/35 is equal to T50/35(Long) + 20°F.
  • RTNOT is the higher of T NOT versus (T50/35 - 60°F).

For the E8018 weld material, where required materials test data were not available from the CMTR, generic values of RTNOT were determined to be 10°F in accordance with NUREG-0800, Section 5.3.2, position 1.1 (4).

Margin Margin is added to account for uncertainties in the values of RTNOT(U), copper and nickel contents, fluence, and calculational procedures. Margin, M, was evaluated from the equation: M = 2 * (aJ + at:.2 ) 1/2 au is the standard deviation for RTNOT(U) au = OaF when RTNOT(U) is a measured value au = 17°F when RTNOT(U) is a generic value for most base metals and welds (or as justified by specific material statistical analyses) at:. is the standard deviation for RTNOT For plates and forgings:

at:. = 1JOF when surveillance capsule data are not used at:. = 8.5°F when surveillance capsule data are used For welds:

at:. = 28°F when surveillance capsule data are not used at:. = 14°F when surveillance capsule data are used

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 11 of 40 Or:,. is not to exceed one half of ~RT NOT, where ~RT NOT is the mean value of the transition temperature shift (change in RTNOT) due to irradiation.

In summary, the procedures that were applied to determine the properties for the extended beltline materials are consistent with those applied for determination of properties for the traditional beltline forgings.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 12 of 40 RAI3.3.2.2.14-1

Background:

LRA and Standard Review Plan (SRP) Sections 3.3.2.2.14 refer to LRA and SRP Tables 3.3.1- 35. These tables address the loss of material due to a cladding breach on stainless steel clad pump casings exposed to treated borated water. These tables recommend "further evaluation" on the part of the staff. The GALL Report recommends managing this aging process through the use of plant-specific aging management program. The applicant states that its charging pumps are neither centrifugal nor constructed from steel clad with stainless steel and that this item is, therefore, not applicable.

Issue:

In its review of LRA Table 3.3.1-35, the staff noted that it is quite common for plants to have interchangeable pumps for safety injection and normal charging. The staff also noted that it is quite common for some of these pumps to be centrifugal and some to be positive displacement. The staff further noted that LRA Section 3.2.2.2.6 implies that the safety injection pumps are centrifugal. Lastly the staff noted that if any of these pumps are stainless steel clad, this item should be considered.

Request:

Please confirm whether the safety injection pumps are stainless steel clad and whether any of these pumps are centrifugal. If these pumps are centrifugal and stainless steel clad, please confirm the issue of loss of material due to cladding breach is being managed or that it is not applicable to these pumps.

DEK Response The Kewaunee safety injection pumps are stainless steel clad carbon steel centrifugal pumps manufactured by Sulzer-Bingham.

Based on NRC Information Notice 80-38, "Cracking in Charging Pump Casing Cladding," and other industry operating experience, loss of material due to a stainless steel cladding breach is associated with the manufacturing process of pumps supplied by the Pacific Pump Division of Dresser Industries. Based on a search of industry databases, there is no operating experience related to loss of material due to a cladding breach for centrifugal pumps manufactured by Sulzer-Bingham. Therefore, loss of material due to cladding breach was determined not to be applicable to the Kewaunee safety injection pumps.

The Kewaunee charging pumps and safety injection pumps are not interchangeable.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 13 of 40 RAI3.4.2.2.3-1

Background:

LRA and Standard Review Plan for Review of License Renewal Application for Nuclear Power Plants (SRP-LR) Sections 3.4.2.2.3 refer to LRA and SRP-LR Tables 3.4. 1-8.

These tables address the loss of material due to general, pitting, crevice and microbiology-influenced corrosion (MIG) as well as fouling on steel piping, piping components and piping elements exposed to raw water. These tables recommend "further evaluation" on the part of the staff. The GALL Report recommends managing this aging process through the use of a plant-specific AMP. The applicant states that components included in the definition of this table are isolated from raw water and that they were not evaluated for aging effects.

Issue:

In its review of LRA Table 3.4. 1-8, the staff noted that the applicant stated that the auxiliary feed pump suction piping was not evaluated for aging. The staff also noted that the applicant describes a motor operated valve which is used to isolate the auxiliary feedwater system from the service water system (raw water). The staff further noted that the content of the piping downstream of the isolation valves is not disclosed. Based on the above, the staff believes that it is necessary to evaluate the entire auxiliary feedwater system for aging. The staff has no theoretical objections to including the evaluation of portions of the system as part of other AMR review items as long as the AMP cited is appropriate and as long as the applicant fully describes, as part of this AMR item, the item under which each component of the system will be evaluated.

Reguest:

Please confirm that the entire auxiliary feedwater system will be evaluated for aging and to modify this AMR item and other AMR items as appropriate to allow the staff to confirm that each portion of the auxiliary feedwater system is being evaluated through the use of appropriate AMP and AMR items.

DEK Response The normal supply of water to the Auxiliary Feedwater System is the condensate storage tanks. The back-up supply of water to the Auxiliary Feedwater System is from the Service Water System. LRA Section 3.4.2.2.3 and license renewal drawing LRM-202-2 (at locations E-9 through E-12) identify that the back-up source of water is isolated from the Auxiliary Feedwater System by normally closed motor-operated valves (SW502, SW601A, and SW601B). Therefore, the Auxiliary Feedwater System was not evaluated for aging effects due to exposure to the Service Water System (raw water) environment. However, the entire Auxiliary Feedwater System (including the auxiliary feedwater pump suction piping downstream of the normally closed motor-operated valves) was evaluated for aging effects due to exposure to the condensate storage tank

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 14 of 40 water supply (treated water - secondary) environment, as indicated for the component type "Pipe" in LRA Table 3.4.2-7.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 15 of 40 RAI3.2.2.5.1.-1

Background:

LRA and SRP-LR Sections 3.3.2.2.5. 1 refer to LRA and SRP-LR Tables 3.3. 1-11.

These tables address hardening and loss of strength due to degradation of elastomers exposed to uncontrolled indoor air. These tables recommend "further evaluation" on the part of the staff. The applicant proposes to manage this aging process through the use of its AMP "External Surfaces Monitoring" (LRA B2.1.10). The GALL Report recommends that this aging process be managed through the use of a plant-specific AMP. The applicant proposes that the AMR items associated with Table 3.3. 1-11 are consistent with the GALL Report in terms of material, environment, and aging effect but a different AMP is credited (Generic Note E).

Issue:

In its review of LRA Table 3.3.1-11, the staff noted that the "External Surfaces Monitoring" AMP proposes to manage the aging of elastomeric materials through the use of visual inspections. The staff also noted that the aging effects being considered are hardening and loss of strength. Given that changes in material properties of elastomeric materials are not always accompanied by a change in appearance, the staff is unaware of how a visual inspection will detect the aging effects under consideration.

The staff further noted that Table 3.3. 1-11 includes both internal and external surfaces of elastomers. Finally, the staff noted that a search of Table 2 items in the LRA associated with Table 3.3. 1-11 reveals only items associated with external surfaces.

Given the nature of the components listed, it appears that most, if not all, of these items should have an additional item associated with their internal surface. The staff questions the apparent lack of these Table 2 items.

Request:

Please clarify how a visual inspection will detect changes in hardness and strength of elastomeric materials or to propose an alternate AMP which includes manual manipulation of the elastomeric material and to explain the apparent lack of AMR items in Table 3.3.1-11 associated with internal surfaces.

DEK Response A visual inspection is not relied on alone to detect changes in hardness and strength of elastomeric materials. The External Surfaces Monitoring program will require performance of visual inspections and physical manipulation by plant personnel qualified to detect hardening and loss of strength of elastomeric materials as described in the response to RAI 82.1.10-1 in DEK letter dated August 17, 2009 (DEK Serial No.09-469) [ADAMS Accession No. ML092320093].

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 16 of 40 As indicated in LRA Tables 3.3.2-10 through 3.3.2-17, "air-moist" and "air-indoor controlled" are the internal environments for elastomeric materials. Hardening and loss of strength/elastomers degradation was identified as an aging effect requiring management for elastomeric materials exposed to these internal environments. The Internal Surfaces Monitoring program within the Work Control Process program (described in DEK letter dated September 25, 2009 [ADAMS Accession No.

ML092720184]) will manage the aging of elastomeric material internal surfaces and includes physical manipulation in addition to visual inspection.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 17 of 40 RAI3.3.2.3-1

Background:

LRA Tables 3.3.2-8 and 3.3.2-27 contain items which address the interior surfaces of elastomeric materials exposed to inert gas. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no AMP is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).

Issue:

In its review of these items, the staff noted that mechanisms other than the nature of the gas in contact with the interior surfaces of elastomeric materials (e.g., temperature and vibration) could cause aging of those materials. Based on the numerous causes for aging of elastomeric materials, the staff cannot conclude from the information provided that the components under consideration will not undergo aging.

Request:

Please include these components in an appropriate AMP or provide sufficient information to allow the staff to conclude that, under the circumstances being considered, no aging will occur.

DEK Response The elastomers (hoses) shown in LRA Tables 3.3.2-8 and 3.3.2-27 are exposed to a gas-inert (nitrogen) environment internally and an air-indoor uncontrolled environment on the external surface. LRA Tables 3.3.2-8 and 3.3.2-27 identify that no aging effects were determined to be applicable to the internal surface of the hoses based on exposure to an inert gas. However, aging effects are applicable to the external surface of the hoses. Cracking and change in material properties due to thermal exposure were determined to be applicable aging effects for the external surfaces of these components. As indicated in the LRA tables, these aging effects will be managed by the Work Control Process program. As described in DEK letter dated September 25, 2009 [ADAMS Accession No. ML092720184], Attachment 2, page 5, physical manipulation and visual inspection techniques will be used to detect cracking and change in material properties of elastomeric materials.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 18 of 40 RAI 3.3.2.3-2

Background:

LRA Tables 3.3.2-10 through 3.3.2-17 contain items which address changes in material properties and cracking of the exterior surfaces of elastomeric materials exposed to uncontrolled indoor air. The applicant proposes to manage this aging process through the use of its AMP, "External Surfaces Monitoring" (LRA B2. 1. 10). The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).

Issue:

In its review of these items, the staff noted that the proposed AMP utilizes visual inspection to identify aging. The staff also noted that identification of cracking in elastomers may be difficult using only visual inspection techniques. The staff further noted that changes in material properties such as hardness and elasticity cannot be reliably identified using only visual inspection techniques.

Request:

Please propose an AMP which includes visual inspection and manual manipulation of a sufficient number or area of elastomeric material at a sufficient inspection frequency to adequately detect cracking or changes in the material properties of those materials.

DEK Response The External Surfaces Monitoring program performs visual inspections and physical manipulation by plant personnel qualified to detect changes in material properties and cracking of elastomeric materials, as described in the response to RAI 82.1.10-1 in DEK letter dated August 17, 2009 [ADAMS Accession No. ML092320093]. On a routine basis, and as part of the External Surfaces Monitoring program, Operations, Health Physics, and Engineering personnel conduct inspections of accessible component surfaces, including elastomeric materials, in normally accessed areas. Inspections of ventilation system components are performed at least once per refueling cycle.

The scope and frequency of inspections performed by the External Surfaces Monitoring program are sufficient to adequately detect cracking and changes in material properties of elastomeric materials in the ventilation systems.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 19 of 40 RAI3.5.2.3.2-1

Background:

LRA Table 3.5.2-2 contains items which address changes in material properties and cracking of the exterior surfaces of elastomeric materials exposed to uncontrolled indoor air. The applicant proposes to manage this aging process through the use of its AMP, "External Surfaces Monitoring" (LRA 82.1.10). The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).

Issue:

In its review of these items, the staff noted that the proposed AMP utilizes visual inspection to identify aging. The staff also noted that identification of cracking in elastomers may be difficult using only visual inspection techniques. The staff further noted that changes in material properties such as hardness and elasticity cannot be reliably identified using only visual inspection techniques.

Request:

Please propose an AMP which includes visual inspection and manual manipulation of a sufficient number or area of elastomeric material at a sufficient inspection frequency to adequately detect cracking or changes in the material properties of those materials.

DEK Response The External Surfaces Monitoring program will perform visual inspections and physical manipulation by plant personnel qualified to detect cracking and changes in the material properties in elastomers, as described in the response to RAI 82.1.10-1 in DEK letter dated August 17, 2009 (DEK Serial No.09-469) [ADAMS Accession No.

ML092320093].

Penetration seals (flexible seals, bellows seals, plates seals) identified in LRA Table 3.5.2-2 are fire protection features. The aging of these penetration seals are managed by both the Fire Protection and External Surfaces Monitoring programs. The inspections performed by the Fire Protection program are consistent with the recommendations of NUREG-1801,Section XI.M26, for both the type and the frequency of inspection. All of the 10 CFR 50 Appendix R-related penetration seals, and 20% of the 10 CFR 50 Appendix A-related penetration seals, are inspected during each refueling outage.

The External Surfaces Monitoring program inspections are performed in conjunction with the Fire Protection program inspections such that the frequency of the inspections are sufficient to detect cracking or changes in material properties of the elastomers.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 20 of 40 RAI3.2.2.2.6-1

Background:

LRA and SRP Sections 3.2.2.2.6 refer to LRA and SRP Tables 3.2.1-12. These tables address loss of material due to erosion of stainless steel high pressure safety injection (charging) pump miniflow orifice exposed to treated borated water. Section 3.2.2.2.6 of the SRP refers to Licensee Event Report (LER) 50-275/94-023. This LER describes a situation in which centrifugal charging pumps had been used as normal charging pumps for a substantial period of time. During this period the miniflow recirculation orifices were enlarged through erosion. This enlargement could allow the flow through the pump to exceed technical specification limits. In the LRA, the applicant states that the centrifugal charging pumps are used as safety injection pumps and are not used as normal charging pumps. The applicant further states that the normal charging pumps are positive displacement pumps which do not have miniflow recirculation orifices.

Issue:

In its review of LRA Table 3.2.1-12 and LER 50-275/94-023, the staff noted that the applicant correctly identifies the issue under consideration as erosion of the miniflow orifices through prolonged use. The staff also noted that the applicant stated that it is currently not using the centrifugal pumps in a manner which would result in prolonged use. The staff further noted that one of the responses to the events of LER 50-275/94-023 was to switch from using the centrifugal pump to the positive displacement pump for normal injection. Based on the ability of the applicant to switch from using the centrifugal pump to the positive displacement pump for normal injection, the staff cannot conclude from the applicant's statement that the positive displacement pump is being used for normal injection that the centrifugal pump has not been used for that purpose In the past. Past use of the centrifugal pump for normal injection could indicate that greater than acceptable erosion has occurred or may occur with minimal additional use during the period of extended operation.

Request:

Please provide information concerning the interchanability of the safety injection pumps and the charging pumps. Additionally, please provide information concerning the operating history of the safety injection pumps so as to allow the staff to determine whether these pumps have been or will be operated for a sufficient period of time to cause erosion of the miniflow orifice.

DEK Response The KPS charging pumps are positive displacement pumps and do not have a mini-flow orifice. The KPS safety injection pumps are centrifugal pumps and they are not interchangeable with the positive displacement charging pumps. In addition, the safety injection pumps are only operated for short periods of time during surveillance testing

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 21 of 40 and filling of the Safety Injection accumulators. Therefore, the safety injection pumps mini-flow orifices are not subject to protracted conditions that would result in erosion.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 22 of 40 RAI 3.3.2.3-3

Background:

LRA Tables 3.3.2-6, 3.3.2-8, 3.3.2-19 and 3.3.2-27 contain items which address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposed to raw water, dry air, lube oil, and inert gas. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no aging management program is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).

Issue:

In its review of these items, the staff noted that "non metallic material" is not defined in the GALL Report and that, in terms of license renewal, it has no meaning. The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.

chlorine), ultraviolet light, and high temperatures. Based on the information provided, the staff cannot conclude that no aging effects will occur to the combination of materials and environments under consideration.

Request:

Given that the term "non metallic" is very broad, please identify the specific material under consideration. Additionally, please justify why this material is not subject to aging under the conditions being considered.

DEK Response Discussion of Internal Aging Effects The non-metallic components shown in LRA Table 3.3.2-6 (Service Water System) consist of valves, piping, and pumps. The non-metallic components are constructed from Polyvinyl Chloride (PCV) and Polyvinylidene Flouride (PVDF) materials. The components are associated with the Service Water Chlorination System and are exposed to sodium hypochlorite on the internal surfaces (identified as a raw water environment in Table 3.3.2-6). A review of recent industry and plant-specific operating experience has identified cracking resulting from exposure to sodium hypochlorite in the non-metallic piping associated with the Service Water Chlorination System. Therefore, cracking due to chemical oxidation is added as an aging effect for the internal surfaces of the non-metallic components in a raw water internal environment shown in LRA Table 3.3.2-6. The Internal Surfaces Monitoring program inspections performed by the Work Control Process program (described in DEK letter dated September 25, 2009 [ADAMS Accession No. ML092720184]) will manage this aging effect such that the component intended functions are maintained.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 23 of 40 The non-metallic components shown in LRA Table 3.3.2-8 (Station and Instrument Air System), which have no aging effects assigned, consist of lubricators and oilers. The bowl associated with these components is a polycarbonate material. The internal surfaces of the components are exposed to lubricating oil and dried air. A review of plant and industry operating experience identified no evidence of polymer degradation due to exposure to dried air or lubricating oil. Therefore, no aging effects were applied to the internal surfaces of these components.

The non-metallic components shown in LRA Table 3.3.2-19 (Diesel Generator System) are filter housings in the diesel starting air system. The filter housing is a polycarbonate material. The internal surfaces of the components are exposed to dried air. A review of plant and industry operating experience identified no evidence of polymer degradation due to exposure to dried air. Therefore, no aging effects were applied to the internal surfaces of these filter housings.

The non-metallic component shown in LRA Table 3.3.2-27 (Miscellaneous Gas System) is flexible tubing used to connect a nitrogen bottle to an instrument air dryer. The tubing is polyethylene. The internal surface of the tubing is exposed to inert nitrogen gas. A review of plant and industry operating experience identified no evidence of polymer degradation due to exposure to inert gases. Therefore, no aging effects were applied to the internal surface of this component.

Discussion of External Aging Effects Kewaunee is located in a rural area on the shore of Lake Michigan. As such, exposure to harsh chemicals (e.g., sulfur dioxide) in the atmosphere that could result from industry is not applicable to the external surfaces of the non-metallic components shown in LRA Tables 3.3.2-6, 3.3.2-8, 3.3.2-19 and 3.3.2-27. Additionally, these components are normally exposed to temperatures less than 95°F, which is well below the temperature rating of the non-metallic material. The external surfaces of the components were evaluated for reduced strength resulting from exposure to ozone and ultraviolet (UV) radiation. However, these components are not located near high voltage electrical equipment and are not exposed to direct sunlight. Although the non-metallic components are exposed to general area fluorescent lighting, a review of plant operating experience identified no evidence of polymer degradation as a result of exposure to limited UV radiation in indoor locations. Therefore, reduced strength due to exposure to ozone or UV radiation exposure was not identified as an applicable aging effect for these components.

Based on the above, no aging effects were identified that could adversely affect the external surfaces of the non-metallic components.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 24 of 40 RAI3.4.2.3.12-1

Background:

LRA Table 3.4.2-12 contains items which address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposed to treated water or steam. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no aging management program is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).

Issue:

In its review of these items, the staff noted that "non metallic material" is not defined in the GALL Report and that, in terms of license renewal, it has no meaning. The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.

chlorine), ultraviolet light, and high temperatures. Based on the information provided, the staff cannot conclude that no aging effects will occur to the combination of materials and environments under consideration.

Request:

Given that the term "non metallic" is very broad, please identify the specific material under consideration. Additionally, please justify why this material is not subject to aging under the conditions being considered.

DEK Response The non-metallic components shown in LRA Table 3.4.2-12, Secondary Sampling System, consist of filter housings, conductivity cell housings, and piping fabricated from polysulfone, polyethersulfone, and polyvinyl chloride (PVC), respectively. The components are associated with the analytical instrumentation panel (secondary sampling station) and are exposed to sample fluids from chemistry-controlled secondary plant systems on the internal surfaces and an air-indoor uncontrolled environment on the external surfaces.

Since the sample fluids are from chemistry-controlled secondary plant systems, the internal surfaces of the components are not exposed to significant levels of contaminants, such as chlorine. Additionally, these components are located downstream of the secondary sample coolers and are not exposed to elevated temperatures. Therefore, no aging effects were identified that could adversely affect the internal surfaces of these non-metallic components.

Kewaunee is located in a rural area on the shore of Lake Michigan. As such, exposure to harsh chemicals (e.g., sulfur dioxide) in the atmosphere that could result from local

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 25 of 40 industry is not applicable to the external surfaces of these components. The external surfaces were evaluated for the potential for reduced strength resulting from exposure to ozone and ultraviolet (UV) radiation. However, these components are not located near high voltage electrical equipment and are not exposed to direct sunlight. Although these non-metallic components are exposed to general area fluorescent lighting, a review of plant operating experience identified no evidence of polymer degradation due to exposure to UV radiation from lighting sources. Therefore, reduced strength due to exposure to ozone or UV radiation exposure was not identified as an applicable affect.

Based on the above, no aging effects were identified that could adversely affect the external surfaces of these non-metallic components.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 26 of 40 RAI 3.5.2.3-6

Background:

LRA Tables 3.5.2-4, 3.5.2-12 and 3.5.2-14 contain items which address the exterior surfaces of non metallic materials exposed to uncontrolled indoor air and the interior surfaces of non metallic materials exposed to raw water. The applicant proposes that there is no aging effect associated with this combination of material and environment and that no aging management program is required. The applicant proposes that for the component, material and environment combination listed the aging effect being considered is not included in the GALL Report (Generic Note H).

Issue:

In its review of these items, the staff noted that "non metallic material" is not defined in the GALL Report and that, in terms of license renewal, it has no meaning. The staff also noted that many polymeric materials are adversely affected by oxidizers (e.g.

chlorine), ultraviolet light, and high temperatures. Based on the information provided, the staff cannot conclude that no aging effects will occur to the combination of materials and environments under consideration.

Request:

Given that the term "non metallic" is very broad, please identify the specific material under consideration. Additionally, please justify why this material is not subject to aging under the conditions being considered.

DEK Response The non-metallic structural member shown in LRA Table 3.5.2-4, which has no aging effects assigned, consists of wood planking. The wood planking is exposed to an external air-indoor uncontrolled environment. The wood planking is protected from weather and is not located in a soil environment which could result in loss of material or change in material properties. A review of plant and industry operating experience identified no evidence of wood degradation due to exposure to an external air-indoor uncontrolled environment. Therefore, no aging effects are applied to this component.

The non-metallic structural member shown in LRA Table 3.5.2-12, which has no aging effects assigned, consists of traveling water screen covers. The traveling water screen covers are fiberglass material. The fiberglass covers are exposed to an external air-indoor uncontrolled environment and an internal raw water environment. The fiberglass covers do not experience ultraviolet radiation or ozone exposure or high voltage currents which could result in loss of strength. A review of plant and industry operating experience identified no evidence of fiberglass degradation due to exposure to an external air-indoor uncontrolled environment or an internal raw water environment.

Therefore, no aging effects are applied to this component.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 27 of 40 The non-metallic commodity group shown in LRA Table 3.5.2-14, which has no aging effects assigned, consists of fire boots. The fire boots are fiberglass material. The fiberglass boots are exposed to an external air-indoor uncontrolled environment. The fiberglass boots do not experience ultraviolet radiation or ozone exposure or high voltage currents which could result in loss of strength. A review of plant and industry operating experience identified no evidence of fiberglass degradation due to exposure to an external air-indoor uncontrolled environment. Therefore, no aging effects are applied to this component.

The non-metallic commodity group shown in LRA Table 3.5.2-14, which has no aging effects assigned, consists of insulation. The insulation is fabricated of calcium silicate, expanded silicate, and fiberglass material. The materials are exposed to an external air-indoor uncontrolled environment. These materials are not exposed to ultraviolet radiation or ozone exposure or high voltage currents, chemicals or temperatures which could result in loss of strength. A review of plant and industry operating experience identified no evidence of calcium silicate, expanded silicate, and fiberglass degradation due to exposure to an external air-indoor uncontrolled environment. Therefore, no aging effects are applied to this component.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 28 of 40 RAI4.2.1-1

Background:

The evaluation of neutron f1uence is provided in LRA Section 4.2. 1, "Neutron Fluence."

Issue/Request:

The LRA does not provide a USAR Supplement summary description of LRA Section 4.2. 1 in LRA Appendix A, "Updated Safety Analysis Report Supplement." Please provide an USAR supplement summary description of the evaluation of neutron f1uence for 52. 1 effective full power years.

DEK Response The following will be added to LRA Appendix A, USAR Supplement, Section A3.1 :

"The calculation of neutron fluence to which reactor vessel materials are exposed is an important input to the evaluation of reactor vessel neutron embrittlement and is governed by regulatory requirements. WCAP-16641 (Reference A3.6-6) provides the calculation of Kewaunee reactor vessel neutron fluence projections to EOLR (i.e., 60 year plant lifetime) based on 52.1 EFPY. Neutron exposure up to Cycle 27 was based upon actual plant operating history, including power uprate that occurred during Cycle 26. Neutron exposure projections beyond the end of Cycle 27 were based upon an operating scenario that consisted of a series of 18 month operating cycles followed by a 25 day refueling outage. The reactor was considered to be operating at full power for the entire 18 month cycle. This full power period coupled with the 25 day refueling outage resulted in a net capacity factor of 95.6% with a total operating time of 33.0 EFPY at EOL and 52.1 EFPY at EOLR. The neutron exposure projections were also based on the continued use of low neutron leakage fuel management.

Kewaunee reactor vessel surveillance Capsule T was removed in 2004 (the fifth capsule removed from the reactor) and WCAP-16641 documents the results of the fluence evaluation for the specimens. The fluence calculations concluded that Capsule T surveillance specimens received a fluence of 5.62E+19 n/crn" (E>1.0 MeV) after irradiation to 24.6 EFPY and the peak reactor vessel clad/base metal interface fluence after 24.6 EFPY of plant operation was 2.60E+19 n/cm" (E>1.0 MeV). The Capsule T specimens have received a fluence equivalent to slightly greater than 52.1 EFPY. The maximum vessel exposures occur on the intermediate shell base material with all other vessel materials experiencing a lower neutron exposure. Certain materials in the extended beltline (inlet nozzles, inlet and outlet nozzle to upper shell welds, upper shell forging, and intermediate shell to upper shell girth weld) are projected to receive fluence greater than 1.0E+ 17 n/cm" during the 40 - 60 year operating period."

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 29 of 40 The following will be added to LRA Appendix A, USAR Supplement, Section A3.6:

"6. WCAP-16641, Revision 0, Analysis of Capsule T from the Dominion Energy Kewaunee Power Station Reactor Vessel Radiation Surveillance Program, Westinghouse Electric Company, LLC, October, 2006."

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 30 of 40 RAI 3.1.2.1.2-1

Background:

The AMP for managing the loss of fracture toughness due to thermal aging embrittlement of reactor coolant system Class 1 pump casing, and valve bodies and bonnets, constructed of cast authentic stainless steel (CASS) materials consists of the American Society of Mechanical Engineers (ASME)Section XI Inservice Inspection (lSI), Subsections IWB, IWC, and IWD program with an exception in that the Edition of the ASME Section XI Code is different than that of the GALL AMP XI.M12. In addition, the LRA states that the CASS Class 1 reactor coolant system loop piping has been evaluated for the effects of aging and found to be not susceptible to thermal aging embrittlement, therefore there is no requirement to manage the effects of thermal aging embrittlement of CASS reactor coolant loop piping for the period of extended operation.

Issue:

The assessment of the loss of fracture toughness due to thermal embrittlement is based on calculated ferrite levels using the Hull's equivalent factors. Other procedures for calculating ferrite content may result in a non-conservative estimation of the fracture toughness of the steel. The GALL Report states, "In the susceptibility screening method, ferrite content is calculated by using the Hull's equivalent factors (described in NUREG/CR-4513, Rev 1) or a method producing an equivalent level of accuracy (+/-6%

deviation between measured and calculated values)."

Request:

Confirm whether the Hull's equivalent factors were used to determine the delta ferrite content of the CASS materials, and if they were not, verify that the method produced an equivalent level of accuracy.

DEK Response Susceptibility screening for the cast austenitic stainless steel (CASS) reactor coolant loop piping was performed consistent with the letter from Christopher Grimes, Nuclear Regulatory Commission to Douglas Walters, Nuclear Energy Institute, License Renewal Issue No. 98-0030, "Thermal Aging Embrittlement of Cast Austenitic Stainless Steel Components," dated May 19, 2000 [ADAMS Accession No. ML003717179], with the exception that delta-ferrite content was determined using the method outlined in ASTM A800, "Standard Practice for Steel Casting, Austenitic Alloy, Estimating Ferrite Content Thereof," rather than the Hull's equivalent factors method identified in the letter.

In accordance with ASTM A800, estimation of ferrite content in the base metal of the reactor coolant loop piping was performed by analysis of the chemical composition of the castings. The ferrite content of the casting was estimated from the equation of the

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 31 of 40 central line of the Schoefer diagram at the composition ratio of "chromium equivalent" (Cre) to "nickel equivalent" (Ni e) determined from the formula in ASTM A800. The ASTM A800 Schoefer diagram method details, provided in Appendix X1 to the Standard, include a description of potential error associated with the estimation of ferrite content based on chemical composition. The probable error determined in the Standard is approximately +3.5% / -2.5% ferrite at ferrite content of 5%; +4.5% / -3.5% at 10%

ferrite; +6% / -4.5% at 15% ferrite; and +8% / -5.5% at 20% ferrite content. As stated in the NRC License Renewal Issue No. 98-0030 letter dated May 19, 2000, the Hull's equivalent factors method produces results with +/- 6% ferrite potential error. The difference in potential error at higher levels of ferrite content between the Hull's equivalent factors method and the Schoefer diagram method provided in ASTM A800 is small, and the Schoefer diagram method used for estimating the ferrite content of the steel was considered to provide an acceptable level of accuracy.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 32 of 40 RAI 3.1.2.1.3-1

Background:

The program for managing cracking due to stress corrosion cracking of austenitic stainless steel reactor coolant system components (AMR line item 3. 1.1-68) consists of Primary Water Chemistry program whereas the program recommended in the GALL Report, for the same line items, consists of ASME Section XI Inservice Inspection (Subsections IWB, IWC, and IWO) and Primary Water Chemistry program. The LRA further states that the KPS program is consistent with the GALL AMP.

Issue:

In LRA Table 3. 1.1, line item 3. 1.1-68, the applicant stated that the cracking due to stress-corrosion cracking of austenitic stainless steel reactor coolant pump thermal barriers heat exchanger, pressurizer man way, and reactor coolant system thermal sleeves is managed by the Primary Water Chemistry program while stress-corrossion cracking (SCC) of stainless steel piping, fittings, pump casings, valve bodies, nozzles, etc. is managed by Primary Water Chemistry as well as ASME Section XI Inservice Inspection program. The applicant further stated that the KPS program is consistent with the GALL AMP. It is not clear how the applicant's program for stainless steel reactor coolant pump thermal barriers heat exchanger, pressurizer manway, and reactor coolant system thermal sleeves is consistent with the GALL AMP.

Request:

Explain how the applicant's program to manage cracking due to SCC is consistent with the programs recommended in the GALL Report. Also, describe how the effectiveness of the program is verified to ensure that cracking is not accruing and the structural and functional integrity of the components will be maintained during extended operation.

DEK Response For the reactor coolant pump thermal barriers (heat exchanger) and the pressurizer manway (including stainless steel insert), the ASME Section XI Inservice Inspection program, Subsections IWB, IWC, and IWD, is added as an additional aging management program and will provide verification of the effectiveness of the Primary Water Chemistry program for management of cracking due to stress corrosion cracking.

This change provides consistency with NUREG-1801 (Item 3.1.1-68).

For the non-pressure boundary thermal sleeves, the One-Time Inspection program within the Work Control Process program, as described in DEK letter dated September 25, 2009 (DEK Serial No.09-597) [ADAMS Accession No. ML092720184], is added as an additional aging management program and will provide verification of the effectiveness of the Primary Water Chemistry program for management of cracking due to stress corrosion cracking. The One-Time Inspection program within the Work Control

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 33 of 40 Process program uses NDE techniques that have been determined to be effective for the identification of stress corrosion cracking in stainless steel. The inspections will verify that unacceptable degradation is not occurring for material and environment combinations that include stainless steel in primary treated water. Indications of degradation would result in an engineering review of the condition through the Corrective Action Program and could result in further corrective actions, such as an expansion of the inspection scope.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 34 of 40 RAI4.7.5-1

Background

Section 4.7.5 of the LRA describes the reactor coolant loop plpmg flaw tolerance evaluation to account for susceptibility of the CASS piping materials to thermal aging embrittlement. The applicant stated that an evaluation of the susceptibility of the loop piping to thermal aging and the potential for flaw growth in the piping due to reduced fracture toughness has been performed consistent with the recommendations of GALL AMP XI.M12.

Issue:

The applicant stated in LRA Section 4.7.5: 'The limiting initial flaw depth for an aspect ratio of 6 is in the crossover leg (28% through-wall). The flaw tolerance evaluation concludes that flaw of this initial size would not grow to critical size (i.e., a size that could result in piping failure at design basis loading conditions, during an additional 30 years of service." Based on these results the applicant concluded that there is no requirement to manage the effects of thermal aging embrittlement of CASS reactor coolant loop piping for the period of extended operation. However, the applicant did not provide sufficient details regarding applied stresses in specific pipe sections, or cyclic crack growth rates, or bounding fracture toughness of thermally aged CASS, to verify the applicant's statement that the initial flaw will not grow to critical size or to check the critical flaw size. For example, the applicant indicated that the number of occurrences of design transients considered in the analysis were based on the revisions for Kewaunee 7.4% uprating and steam generator replacement, however, it is not clear whether the 7.4% uprating was considered in determining the design stresses for the evaluation. Also, although the applicant stated that that the loop piping was constructed of CF-8M steel with less than 25% delta ferrite, the applicant did not confirm that it did not contain niobium. Typically, niobium is not specified in CF-8M steel. The recommendations of XI.M12 are not applicable to niobium bearing steels. In addition, the applicant stated that an environmental factor of 2 was applied to the crack growth reference curves for austenitic stainless steel in air to account for the effect of pressurized water reactor (PWR) environment on growth rates. However, the applicant did not provide the basis for choosing an environmental factor of 2. Several recent studies have reported data showing that the fatigue crack growth rates can be enhanced appreciably in PWR primary coolant environment at low loading frequencies.

Request:

Provide the following information:

1. Confirm that the loop piping material is not niobium bearing.
2. Confirm that the Kewaunee 7.4% uprating was considered in determining the design stresses for the flaw tolerance evaluation.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 35 of 40

3. The details regarding flaw growth analyses, in particular, the technical basis for the choice of the environmental factor of 2 for fatigue crack growth rates in PWR environment.

DEK Response

1. The reactor coolant loop piping was supplied in accordance with material specification American Society for Testing and Materials (ASTM) A351, Grade CF-8M. This specification does not require the addition of niobium (or columbium) for Grade CF-8M steel. Additionally, the chemical compositions for the loop piping heats were reviewed and there was no indication of niobium (or columbium) content.
2. The Kewaunee 7.4% uprating was considered in determining the design stresses for the flaw tolerance evaluation.
3. The flaw growth analyses associated with the reactor coolant loop piping flaw tolerance evaluation are based on methods described in the ASME Boiler and Pressure Vessel Code,Section XI, Subsection IWB-3640. The use of an environmental factor of 2 applied to the crack growth rate determined for austenitic stainless steel in air, to account for the effect of pressurized water reactor (PWR) environment, is based on the factor recommended for the PWR environment in, "Evaluation of Flaws in Austenitic Steel Piping - Section XI Task Group for Piping Flaw Evaluation," Transactions of ASME, Journal of Pressure Vessel Technology, Vol. 108, Aug. 1986, pp. 352-366.

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 36 of 40 RAI 82.1.1 (Alloy 600 Inspections)

Background/Issue:

This program is established to ensure that augmented lSI of all alloy 600 components and welds in the reactor coolant system at PWR-designed light water reactors will continue to be performed per the latest NRC requirements and guidance.

On September 10, 2008, in Volume 73 Number 176 of the Federal Register, the NRC published a final rule invoking several requirements to address this issue. The NRC mandated the use of ASME Code Case N-729-1, as conditioned by the NRC, to establish new requirements for long term inspection of reactor pressure vessel upper heads. This action, once implemented by a licensee, withdrew the requirements of the First Revised NRC Order EA-03-009, dated February 20,2004, from that licensee. The NRC also mandated the use of ASME Code Case N-722, as conditioned by the NRC, to establish long term inspection requirements for the following components if they contain the primary water stress-corrosion cracking (PWSCC) susceptible materials designated Alloys 600/182/82; Reactor Vessel Reactor Pressure Vessel Bottom Mounted Nozzles Hot Leg Nozzle-to-Pipe Connections Cold Leg Nozzle-to-Pipe Connections Instrument Connections Steam Generators Hot Leg Nozzle-to-Pipe Connections Cold Leg Nozzle-to-Pipe Connections Bottom Channel Head Drain Tube Penetration Primary Side Hot Leg Instrumentation Connections Primary Side Cold Leg Instrumentation Connections Pressurizer Heater Penetrations Spray Nozzle-to-Pipe Connections Safety and Relief Nozzle-to-Pipe Connections Surge Nozzle-to-Pipe Connections Instrument Connections Drain Nozzle-to-Pipe Connections Piping Hot Leg Inslfument Connections Cold Leg Instrument Connections Hot Leg Full Penetration Welds Cold Leg Full Penetration Welds

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 37 of 40 On October 22, 2008, the NRC issued Regulatory Issue Summary 2008-25, which stated the regulatory approach for addressing PWSCC of dissimilar metal butt welds in PWR primary coolant system piping. This approach was established in conjunction with the mandated inspections of ASME Code Case N-722, as conditioned by the NRC. In 2005, an industry group, the Materials Reliability Program (MRP) issued industry mandated guidelines for the examination of dissimilar metal butt welds through a report designated MRP-139. Industry has been implementing this inspection guideline and mitigating welds to address PWSCC. The NRC staff has reviewed the MRP-139 guidelines and additional MRP interim guidance letters. The NRC staff believes that MRP-139 and the MRP interim guidance letters, with the exception of the reinspection interval for unmitigated pressurizer dissimilar metal butt welds that have been previously addressed by certain plant specific Confirmatory Action Letters, provide adequate protection of public health and safety for addressing PWSCC in butt welds for the near term pending incorporation by reference into 10 CFR 50.55a of an ASME Code Case containing comprehensive inspection requirements. The NRC staff is monitoring the industry's MRP-139 inspections and operating experience and will use this information to determine if any additional regulatory actions are necessary.

On January 26, 2009, ASME Boiler and Pressure Vessel Code published Code Case N-770, "Alternative Examination Requirements and Acceptance Standards for Class 1 PWR Piping and Vessel Nozzle Butt Welds Fabricated with UNS N06082 or UNS W86182 Weld Filler Material With or Without Application of Listed Mitigation Activities."

It is the intention of the NRC to incorporate the requirements of ASME Code Case N-770 into 10 CFR 50.55a, as conditioned by the NRC, in the latest rulemaking activity to update 10 CFR 50.55a which is expected to be completed by December 2010.

Request:

Based on these actions, the NRC finds that the AMP requirements, to ensure effective augmented inservice inspections (lSI) of all alloy 600 based components and welds in the reactor coolant system at PWR-designed light water reactors, need to be updated to state compliance with current regulatory requirements of 10 CFR 50.55a.

DEK Response LRA Section B2.1.1 identifies all of the Alloy 600 base metal and Alloy 82/182 dissimilar metal welds, and Alloy 690 base metal and Alloy 52/152 dissimilar metal welds, managed by the Alloy 600 Inspections program. The difference between the scope of the Alloy 600 Inspections program and the list of potential locations in RAI B2.1.1 Background/Issue is due to Kewaunee plant-specific design and materials differences.

The Alloy 600 Inspections program has been updated to be consistent with the regulatory and industry initiatives for managing PWSCC susceptible materials designated Alloys 600/182/82. The table below identifies the current inspection bases,

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 38 of 40 In addition to the ASME Boiler and Pressure Vessel Code,Section XI, requirements, that are implemented for each of the locations included in the program.

,

Locations Additional Inspection Bases I Reactor Vessel closure head penetrations

~ (control rod drive mechanisms, reactor Code Case N-729-1 vessel level instrument system, and head vent) and associated J-groove welds Reactor Vessel bottom head instrument tube Code Case N-722 penetrations and associated J-groove welds Reactor Vessel safety injection nozzles MRP-139 buttering weld Reactor Vessel core support guide lug/weld None Steam Generator primary nozzles safe Code Case N-722 end/buttering MRP-139 As noted in RAI B2.1.1 Background/Issue, Code Case N-770 was not issued until January 2009. This code case has not yet been incorporated into the Alloy 600 Inspections program, but, as required, will be incorporated into the program once the code case has been incorporated into 10 CFR 50.55a.

The Alloy 600 Inspections program augmented inservice inspections of Alloy 600-based components and welds in the Reactor Coolant System have been updated to be in compliance with the current regulatory requirements of 10 CFR 50.55a.

The description of the Alloy 600 Inspections program in LRA Appendix A, USAR Supplement, Section A2.1.1 will be changed to:

"Program Description The Alloy 600 Inspections program is a plant-specific program that consists of the applicable ten elements as described in Appendix A of NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants."

The program meets the NUREG-1801 expectation to have a plant-specific program for managing nickel alloy materials to comply with the applicable NRC publications and industry guidelines.

The Alloy 600 Inspections program manages the aging effects of primary water stress corrosion cracking in Alloy 600 base metal and Alloy 82/182 dissimilar metal welds and Alloy 690 base metal and Alloy 52/152 dissimilar metal welds. The program performs visual/bare metal, liquid penetrant, eddy current, and ultrasonic examinations to detect cracking of the in-scope components in accordance with the

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 39 of 40 ASME Section XI Inservice Inspection, Subsections I we, I we, and IWD program, which is consistent with the regulatory requirements of 10 CFR 50.55a."

Serial No.09-680 Docket No. 50-305 Attachment 1/Page 40 of 40 RAI 3.1.2.2.3.2.-1 Backqround:

The staff noted that LRA Table 3.1.2-1 subcomponents, "Primary Nozzles (and cladding)" and "Upper, Intermediate and Lower Shell (and cladding)," credit the Reactor Vessel Surveillance program for managing loss of fracture toughness aging effect on them. They represent GALL AMR Item IV.A2-17 for reactor pressure vessel (RPV) nozzles and GALL AMR Item IV.A2-24 for RPV shell, including beltline welds.

Issue/Request:

"Beltline welds," which are mentioned in GALL AMR Items IV.A2-17 and IV.A2-24 and SRP-LR Section 3. 1.2.2.3.2, have not been specified explicitly as part of the LRA Table

3. 1.2-1 subcomponents discussed above. Please resolve this discrepancy because regardless of the selected methodology (Charpy V-notch or Master Curve) for evaluation of material embrittlement, a Reactor Vessel Surveillance program is needed for managing loss of fracture toughness aging effect on relevant RPV materials, including welds.

DEK Response The "Primary Nozzles (and cladding)" and "Upper, Intermediate and Lower Shell (and cladding)" components which credit the Reactor Vessel Surveillance program for managing the aging effect of loss of fracture toughness due to neutron irradiation embrittlement includes the associated component weld(s) as required by Appendix H to 10 CFR Part 50, "Reactor Vessel Material Surveillance Program Requirements."

Serial No.09-680 Docket No. 50-305 ATTACHMENT 2 REVISED RESPONSES FOR RAls 2.3.3.18-1 AND 82.1.14-3 (Replaces original responses in their entirety)

KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.

Serial No.09-680 Docket No. 50-305 Attachment 2/Page 1 of 6 RAI2.3.3.18-1

Background

For KPS, the staff reviewed the LRA; drawings; updated safety analysis report, Sections 7.7.5, 8.2.2, 9.6.1, and Table 8.2-1; and the following fire protection current licensing basis documents listed in the KPS Operating License Condition 2.C(3):

Safety Evaluation Reports dated November 25, 1977, December 12, 1978, and supplement issued on February 13, 1981.

Issue The staff has identified that fire protection systems and components discussed in the following sections have been excluded from the scope of license renewal and an AMR.

These systems and components were not included in the license renewal boundaries and appear to have fire protection intended functions required for compliance with Title 10 of the Code of Federal Regulations (CFR) 50.48, "Fire protection," as stated in 10 CFR 54.4. Therefore, in order to complete our review, the staff requires responses to the following RAls:

Request The LRA drawing LRM-202-3 show fire hose connections at locations F9, F10, F11, G9, G10, and G11 as out of scope (i.e., not colored in brown). The staff requests that the applicant verify whether the above fire hose connections are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21 (a)(1). If these hose connections are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

Original DEK Response These non-safety-related fire hose connections shown at locations F-9, F-10, F-11, G-9, G-10, and G-11 on license renewal drawing LRM-202-3 are used only for non-fire purposes (e.g. station services) and do not perform a license renewal intended function.

Additionally, these hose connections are not credited as seismic anchors and LR Notes 6 and 7 on license renewal drawing LRM-202-3 indicate why the service water lines associated with the hose connections are omitted from the scope of license renewal for spatial considerations under 10 CFR 54.4(a)(2).

Revised DEK Response The hose connections shown at locations F-9, F-10, F-11, G-9, G-10, and G-11 on license renewal drawing LRM-202-3 are connections that can be used for general plant

Serial No.09-680 Docket No. 50-305 Attachment 2/Page 2 of 6 service. These hose connections are only used for non-fire purposes (e.g. station services) and do not perform a license renewal intended function. Additionally, these hose connections are not credited as seismic anchors and LR Notes 6 and 7 on license renewal drawing LRM-202-3 indicate why the service water lines associated with the hose connections are omitted from the scope of license renewal for spatial considerations under 10 CFR 54.4(a)(2).

Fire Hose Stations that are a part of the Service Water (SW) System, such as the one shown at location 8-6 on license renewal drawing LRM-202-3, are designated as Fire Hose Stations and have been included within the scope of license renewal for 10 CFR 54.4(a)(3).

Serial No.09-680 Docket No. 50-305 Attachment 2/Page 3 of 6 RAI82.1.14-3

Background

In Exception #5 of LRA Section B2.1.14, the applicant states that KPS does not perform multi-level sampling of the fuel oil day tanks. Instead a one-gallon sample is taken from the bottom of the tank on a monthly basis to allow for a visual inspection for the presence of water and sediment.

Issue The LRA did not provide the justification and the thresholdlcriteria that will be used for the visual inspection of the one-gallon samples taken from the day tanks on a monthly basis.

Request

  • Please provide a justification that a visual inspection of this sample is sufficient in-lieu of a laboratory analysis of the sample as described in ASTM 04057. Provide and justify the thresholdlcriteria that will be used for this visual inspection of the sample, clearly identifying when corrective actions will be taken. Clarify how a visual inspection is capable of quantifying the amount of water/sediment/particulates that is in the one-gallon sample of fuel oil.
  • Clarify if there is some type of filter or filtration that exists between the respective fuel oil storage tank and fuel oil day tank that would limit the amount of contaminants entering the day tank.
  • Clarify whether the sample that is taken from the fuel oil day tanks is a true bottom sample or is it taken from another type of configuration. If it is not a true bottom sample please clarify this other type of configuration and justify that there is not a need to remove the accumulated water/sediment/contamination from the tank bottom that is not flushed out during the monthly removal of the one-gallon sample.

Original DEK Response Laboratory testing of the emergency diesel generators (EDG) and technical support diesel (TSC) day tanks fuel oil will be pertormed consistent with the quarterly surveillance frequency for the fuel oil storage tanks and the acceptance criteria requirements specified in ASTM 04057. Multi-level testing of the day tanks is not warranted due to the relatively small volume of the day tanks and the high turnover of fuel oil due to periodic testing.

Serial No.09-680 Docket No. 50-305 Attachment 2/Page 4 of 6 The sample points for the EOG and TSC day tanks tap off the supply lines to the diesels, so the samples are representative of what is being drawn or used by the diesel.

The EOG fuel oil day tanks have a riser three inches from the bottom of the tank, while the TSC OG day tank provides for a true bottom sample. There is no type of filtration located between the respective fuel oil storage tanks and fuel oil day tanks.

As a result of this commitment for day tank sampling and laboratory analysis, the LRA Appendix 8, Section 82.1.14 is supplemented by the removal of Exception 5.

As stated in the response to RAI 82.1.15-1, a one-time inspection will be performed on the fuel oil day tanks prior to the period of extended operation. The quarterly laboratory analysis combined with a confirmatory one-time inspection provides assurance that the effects of aging will be adequately managed through the period of extended operation.

The following commitment will be added to LRA Appendix A, USAR Supplement, Table A6.0-1 :

Item Commitment Source Schedule 30 Quarterly laboratory Fuel Oil Chemistry Prior to the Period of testing of the EOG Extended Operation and TSC DG day tank fuel oil samples will be performed. The testing and acceptance criteria will be consistent with that specified ASTM 04057 Revised DEK Response Laboratory testing of fuel oil for water, sediment, and particulates will be performed on the emergency diesel generators (EDG) and technical support center (TSC) diesel generator day tanks, consistent with the quarterly surveillance frequency for the fuel oil storage tanks. The acceptance criteria for water and sediment will be consistent with the requirements specified in ASTM 0975-06b. The acceptance criteria for particulates will be consistent with ASTM 06217. Multi-level testing of the day tanks is not warranted due to the relatively small volume of the day tanks and the high turnover of fuel oil due to periodic testing. The day tank volume and turnover rate are discussed in the OEK Response to RAI 82.1.14-2 provided by letter dated August 17, 2009 [ADAMS Accession No. ML092320093].

The sample points for the EDG and TSC day tanks tap off the supply lines to the diesels, so the samples are representative of what is being drawn or used by the diesel.

The EOG fuel oil day tanks have a riser three inches from the bottom of the tank, while

Serial No.09-680 Docket No. 50-305 Attachment 2/Page 5 of 6 the TSC DG day tank provides for a true bottom sample. There is no filtration located between the respective fuel oil storage tanks and fuel oil day tanks.

As a result of this commitment for day tank sampling and laboratory analysis, Exception 5 of the LRA Section 82.1.14, Fuel Oil Chemistry, is replaced with the following:

"Exception 5: Diesel Generator Day Tank Fuel Oil Sampling The Fuel Oil Chemistry program provides for monthly visual inspections and will be enhanced to provide for quarterly laboratory analysis of fuel oil samples obtained from the bottom of the day tanks in lieu of taking multilevel samples of the day tanks as recommended by NUREG-1801, Section X1.M30.

Justification The Emergency Diesel Generators Fuel Oil Day Tanks and the Technical Support Center Diesel Generator Fuel Oil Day Tank are supplied by the diesel generator fuel oil storage tanks. Each day tank has an approximate one-gallon sample of fuel removed from the tank bottom each month to allow for visual inspection and quarterly analysis for the presence of water and sediment.

Sampling at this location, where water and sediment would accumulate, provides for effective removal of contaminants from the day tank contents and ensures the quality of the fuel oil being supplied to the diesel generators. The relatively small volume of the day tanks and the high turnover of fuel oil support the justification for not needing to perform multilevel testing of the day tanks. In addition, multi-level samples are obtained from the fuel oil storage tanks and analyzed quarterly such that ingress of contaminants to the day tanks is not expected.

Therefore, the intent of NUREG-1801,Section XI.M30, that the quality of the fuel oil be monitored and maintained is met for the day tanks.

Program Elements Affected

  • Element 4: Detection of Aging Effects The frequent sampling of the fuel oil day tanks, combined with the multi-level sampling of the diesel generator fuel oil storage tanks, ensures that water and sediment will not accumulate to a significant extent in the day tanks. Along with visual inspection and quarterly analysis of the fuel oil for contaminants, the one-gallon sample of fuel that is drained each month from the day tank effectively removes contaminants that may result in aging effects of concern, therefore meeting the intent of NUREG-1801,Section XI.M30."

As stated in the response to RAI 82.1.15-1 provided in letter dated August 17, 2009

[ADAMS Accession No. ML092320093], a one-time inspection will be performed on the fuel oil day tanks prior to the period of extended operation. The quarterly laboratory analysis combined with a confirmatory one-time inspection provides assurance that the effects of aging will be adequately managed through the period of extended operation.

Serial No.09-680 Docket No. 50-305 Attachment 2/Page 6 of 6 The following commitment will be added to LRA Appendix A, USAR Supplement, Table A6.0-1:

Item Commitment Source Schedule 30 Quarterly laboratory testing of fuel oil samples for Fuel Oil Chemistry Prior to the Period of water, sediment and particulates will be performed Extended Operation on the Emergency Diesel Generators and Technical Support Center Diesel Generator day tank. The testing acceptance criteria will be consistent with the requirements specified in ASTM D975-06b for water and sediment and ASTM D6217 for particulates.

Serial No.09-680 Docket No. 50-305 ATTACHMENT 3 ADDITIONAL EXCEPTIONS FOR COMPRESSED AIR MONITORING PROGRAM KEWAUNEE POWER STATION DOMINION ENERGY KEWAUNEE, INC.

Serial No.09-680 Docket No. 50-305 Attachment 3/Page 1 of 2 Compressed Air Monitoring Program Supplemental Information During the NRC Region III License Renewal Inspection, it was identified that the two deviations from the NUREG-1801,Section XI.M24, "Compressed Air Monitoring" aging management program (AMP) identified in the basis document for the Compressed Air Monitoring program had not been included as exceptions in the LRA Section 82.1.9, Compressed Air Monitoring, program description.

To clarify these deviations, the following exceptions to the NUREG-1801,Section XI.M24 AMP are identified for the Compressed Air Monitoring program:

Exception 2: Compressed Air System Sampling Locations The Station and Instrument Air System and the Emergency Diesel Generator air start subsystems are not sampled at various locations as recommended by NUREG-1801,Section XI.M24.

Justification The sample point for the Station and Instrument Air System is downstream of the system dryer tower. The sample points for the Emergency Diesel Generator air start subsystems are downstream of the dryer for each subsystem.

Since the systems are normally pressurized, the only source for contaminates or moisture into the system would be via the respective compressors.

Therefore, measuring the quality of the air as it enters the system provides an accurate representation of the quality of the air in the systems.

Program Elements Affected

  • Element 1: Scope of Program Monitoring the compressed air as it enters the system provides an accurate representation of the quality of the air to ensure that the compressed air systems can perform their intended function.

Exception 3: Sampling Results Trending The sample data for the Station and Instrument Air System and the Emergency Diesel Generator air start subsystems are not trended as recommended by NUREG-1801,Section XI.M24.

Justification Specific chemistry control parameter limits have been established for the Station and Instrument Air System and the Emergency Diesel Generator air start subsystems. These limits were established based on ANSI/ISA-7.0.01-

Serial No.09-680 Docket No. 50-305 Attachment 3/Page 2 of 2 1996 to support proper operation of the components supplied with compressed air. Measured chemistry parameters are compared to these control parameters and action is taken to restore the parameters within specification if out of specification conditions are identified.

Maintaining the compressed air system air quality in accordance with ANSI/ISA-7.0.01-1996 provides sufficient margin to ensure continued system function. Data trending of the control parameter results would not provide information useful for aging management. Chemistry procedures require that out of specification conditions are documented in the Corrective Action Program.

Program Elements Affected

  • Element 5: Monitoring and Trending Maintaining the compressed air system air quality in accordance with ANSI/ISA-7.0.01-1996 ensures that the compressed air systems can perform their intended function.