| {{#Wiki_filter:Code of Federal Regulations | | {{#Wiki_filter:OFFICIAL USE ONLY - PROPRIETARY INFORMATION February 4, 2019 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066 |
|
| |
|
| /RA/}} | | ==SUBJECT:== |
| | DRAFT SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-16260-P/WCAP-16260-NP, REVISION 2, THE SPATIALLY CORRECTED INVERSE COUNT RATE (SCICR) METHOD FOR SUBCRITICAL REACTIVITY MEASUREMENT (EPID: L-2017-TOP-0064) |
| | |
| | ==Dear Mr. Gresham:== |
| | |
| | By letter dated December 14, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17348B293), Westinghouse Electric Company (Westinghouse) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report (TR) WCAP-16260-P/WCAP-16260-NP, Revision 2, The Spatially Corrected Inverse Count Rate (SCICR) Method for Subcritical Reactivity Measurement. By letter dated August 9, 2018 (ADAMS Accession No. ML18207A226), the NRC issued its first round of the request for additional information (RAI) questions. By letter dated September 13, 2018 (ADAMS Accession No. ML18257A061), Westinghouse provided responses to these RAI questions. By letter dated September 24, 2018 (ADAMS Accession No. ML18263A197), the NRC issued its second round of RAI questions. By letter dated October 24, 2018 (ADAMS Accession No. ML18299A090), |
| | Westinghouse provided responses to the second round of RAI responses. |
| | Enclosed for Westinghouse review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR WCAP-16260-P/WCAP-16260-NP, Revision 2. |
| | Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we believe that the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for you to comment on the proprietary aspects and provide any factual errors or clarity concerns contained in the SE. The final SE will be issued after making any necessary changes and a non-proprietary version will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE. |
| | OFFICIAL USE ONLY - PROPRIETARY INFORMATION |
| | |
| | OFFICIAL USE ONLY - PROPRIETARY INFORMATION J. Gresham To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes. |
| | If you have any questions, please contact Ekaterina Lenning at 301-415-3151. |
| | Sincerely, |
| | /RA/ |
| | Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation DOCKET 99902038 |
| | |
| | ==Enclosure:== |
| | |
| | Draft SE (Proprietary) |
| | OFFICIAL USE ONLY - PROPRIETARY INFORMATION |
| | |
| | Pkg.- ML19022A047; Letter- ML19022A135; Enclosure- ML19022A110 *concurred via e-mail NRR-106 OFFICE NRR/DLP/PLPB/PM NRR/DLP/PLPB/LA NRR/DSS/SNPB/BC NRR/DLP/PLPB/BC NAME ELenning DHarrison* RLukes* DMorey DATE 01/22/2019 1/31/2019 2/04/2019 2/04/2019}} |
Latest revision as of 07:29, 20 October 2019
Letter Sequence Draft Approval |
---|
EPID:L-2017-TOP-0064, Request for Additional Information for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement (Approved, Closed) |
|
MONTHYEARML18207A3592018-08-0909 August 2018 Non-Proprietary Enclosure 1 Request for Additional Information for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement Project stage: RAI ML18207A2172018-08-0909 August 2018 Request for Additional Information for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement Project stage: Request ML18207A2262018-08-0909 August 2018 Cover Letter Request for Additional Information Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement Project stage: RAI ML18257A0652018-09-13013 September 2018 Response to Request for Additional Information Westinghouse Electric Company WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: Response to RAI ML18257A0632018-09-13013 September 2018 Application for Withholding Proprietary Information from Public Disclosure Project stage: Request ML18257A0622018-09-13013 September 2018 Response to Request for Additional Information Westinghouse Electric Company WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: Response to RAI ML18263A1972018-09-24024 September 2018 Request for Additional Information Westinghouse Electric Co. WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement TR - Second Round Project stage: RAI ML19022A0162018-12-27027 December 2018 Attendees Closed Meeting 12-27-18 WCAP-16260-P Project stage: Request ML19022A0722019-01-28028 January 2019 Summary of Meeting with Westinghouse Electric Company to Discuss RAI Response Related to NRC Review of WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: RAI ML19022A1352019-02-0404 February 2019 Draft Safety Evaluation WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: Draft Approval ML19078A0482019-04-12012 April 2019 Cover Letter for the Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement. Project stage: Approval ML19077A2592019-04-12012 April 2019 Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement Project stage: Request ML19078A0342019-04-12012 April 2019 Enclosure 1 - Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement. Project stage: Approval ML19078A0432019-04-12012 April 2019 Attachment 1 - Resolution of Comments Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Meas Project stage: Approval 2018-09-24
[Table View] |
|
---|
Category:Letter
MONTHYEARML24262A2272024-09-18018 September 2024 Transmittal of Additional Errata Pages for WCAP-18830-P (Proprietary) and WCAP-18830-NP (Non-Proprietary), Turkey Point Fuel Storage Criticality Analysis for 24 Month Cycles ML24228A2952024-08-15015 August 2024 Westinghouse Electric Company, LLC - NRC Semi-Annual Discharge Report (Jan - June 2024) ML24176A2762024-06-24024 June 2024 Westinghouse Electric Company LLC, Submittal of Slides for the June 27, 2024, Partially Closed Meeting with NRC Staff on the Designation of Buildings as Items Relied on for Safety ML24173A2992024-06-24024 June 2024 Westinghouse Columbia Fuel Fabrication Facility – Inspection Schedule for Calendar Year 2025 ML24138A1152024-05-21021 May 2024 Cover Letter - the U.S. Nuclear Regulatory Commission Approval Letter for Westinghouse Emergency Plan Change Request for Columbia Fuel Fabrication Facility ML24134A2742024-05-13013 May 2024 Submittal of Slide Packages for the May 16, 2024 Pre-Application Meeting with NRC on the Proposed License Amendment Request Re Low Enriched Uranium Plus Expansion at Columbia Fuel Fabrication Facility ML24128A2662024-05-13013 May 2024 Notification of New Licensing Project Manager for Westinghouses SNM-1151 for the Columbia Fuel Fabrication Facility ML24130A2492024-05-0909 May 2024 Submittal of Information in Support of Surry Power Station Unit 1 Thermal Shield Flexure Replacement Campaign ML24110A0502024-04-22022 April 2024 Westinghouse Columbia Fuel Fabrication Facility - Integrated Inspection Report 07001151/2024001 ML24110A1442024-04-19019 April 2024 Response to Request for Additional Information - Westinghouse Request for Prior Approval of Revision 24 of the Columbia Fuel Fabrication Facility (CFFF) Site Emergency Plan ML24109A0002024-04-19019 April 2024 Public Meeting Summary - Licensee Performance Review for Westinghouse Columbia Fuel Fabrication Facility, Docket Number 70-1151 ML24080A5072024-03-20020 March 2024 Westinghouse, Request for Prior Approval of Revision 24 of the Columbia Fuel Fabrication Facility (CFFF) Site Emergency Plan ML24074A2962024-03-19019 March 2024 Cover Letter for WEC Correction to Amendment 3 ML24064A2542024-03-0707 March 2024 Westinghouse Electric Company, Licensee Performance Review of Licensed Activities - Nuclear Regulatory Commission Inspection Report No 70-1151/2024-005 ML24025A1292024-02-23023 February 2024 Westinghouse Electric Company, LLC, - Amendment 2, Request for Exemption from 24-Hour Reporting Requirement of Title 10 of the Code of Federal Regulations Paragraph 70.50(B)(1) ML24023A6952024-01-26026 January 2024 Westinghouse Columbia Fuel Fabrication Facility, U.S. Nuclear Regulatory Commission Inspection Report Number 07001151/2023004 ML24026A1512024-01-25025 January 2024 Westinghouse Electric Company, LLC, Notice of Intent to Fabricate Low Enriched Uranium (Leu+) ML24017A2252024-01-22022 January 2024 Westinghouse Electric Company, LLC, Conveyance of Revised Standby Trust Agreement to Support the Decommissioning Funding Plan (Enterprise Project Identifier L-2023-DFA-0009) ML23349A2722023-12-14014 December 2023 Westinghouse, Submittal of Monthly Progress Reports Under Consent Agreement 19-02-HW with the South Carolina Department of Health and Environmental Control ML23338A3372023-12-0404 December 2023 Submittal of Amendment 4 to Standby Trust Agreement (STA) for License Nu. SNM-1107, Replacement of Trust Fund with Additional Surety Bonds, and Certification of Financial Assurance for SNM-1107 ML23311A0032023-11-0606 November 2023 Westinghouse Columbia Fuel Fabrication Facility, U.S. Nuclear Regulatory Commission Inspection Report Number 70-1151/2023-402 (Cover Letter) ML23296A0362023-10-24024 October 2023 Westinghouse Columbia Fuel Fabrication Facility - Integrated Inspection Report 07001151/2023003 ML23240A5082023-08-28028 August 2023 Westinghouse Electric Company LLC - NRC Semi-Annual Discharge Report (January- June 2023) ML23230B2022023-08-18018 August 2023 Westinghouse, Supplemental Information for Request for Modification to Temporary License Conditions for Sampling, Analysis and Disposition of Hematite Ash Material ML23216A0712023-08-0404 August 2023 Westinghouse Columbia Fuel Fabrication Facility Physical Security Core Inspection Report 07001151/202340 ML23202A1472023-07-24024 July 2023 Westinghouse Columbia Fuel Fabrication Facility Integrated Inspection Report 07001151/2023002 ML23150A2362023-07-0303 July 2023 Letter to Westinghouse Regarding Effluent Testing Issue ML23184A1512023-06-29029 June 2023 Westinghouse Columbia Fuel 2023 Special Nuclear Material Inventory Summary Report Revision ML23171B1502023-06-20020 June 2023 Westinghouse Columbia Fuel 2023 Special Nuclear Material Inventory Summary Report ML23160A2612023-06-0909 June 2023 Westinghouse, Request for Modification to Temporary License Conditions for Sampling, Analysis and Disposition of Hematite Ash Material ML23139A1942023-06-0505 June 2023 Westinghouse Electric Company LLC - Approval of Environmental Sampling and Monitoring Program ML23138A3762023-05-18018 May 2023 Westinghouse Submittal of Columbia Fuel Fabrication Facility Site Emergency Plan, Revision 23 ML23096A2812023-05-15015 May 2023 Letter - Transfer of Control Approval 2023 ML23094A1582023-05-0505 May 2023 Westinghouse Electric Company, LLC - Revision to Temporarily Store Hematite Ash Above License Limits and Removal of Uranium Flywheel ML23115A2382023-04-26026 April 2023 Westinghouse Columbia Fuel Fabrication Facility - Integrated Inspection Report 07001151/2023001 ML23114A3592023-04-24024 April 2023 Westinghouse Submittal of Environmental Sampling and Monitoring Program for NRC Review and Approval ML23114A3612023-03-23023 March 2023 Enclosures 2 & 3 - SCDHEC Approval Letter of Westinghouse Ri Report, Dated March 23, 2023 and Environmental Sampling and Monitoring Program Section of SNM-1107 License Application ML23058A4482023-02-27027 February 2023 Request for Threshold Determination for Interim Transaction Included in December 20, 2022 Application for Consent to Indirect Change of Control with Respect to a Materials License, Export Licenses, and Notification Regarding Other Approvals ML23058A2722023-02-27027 February 2023 Westinghouse, NRC Semiannual Discharge Report July - December 2022 ML23053A0712023-02-17017 February 2023 Westinghouse Electric Company LLC, Supplement to Application for Consent to Indirect Change of Control with Respect to a Materials License, Export Licenses, and Notification Regarding Other Approvals and Request for Threshold Determination ML23053A0752023-02-17017 February 2023 Westinghouse Electric Co. - Supplement 2 to Application for Consent to Indirect Change of Control with Respect to a Materials License, Export Licenses, and Notification Regarding Other Approvals and Request for Threshold Determination ML23047A4562023-02-16016 February 2023 Westinghouse, Response to Request for Additional Information - Request for Temporary License Amendment for Storage of Hematite Ash ML23030B8552023-01-30030 January 2023 Westinghouse 10CFR70.72 Facility Change Report ML23024A2312023-01-30030 January 2023 Westinghouse Columbia Fuel Fabrication Facility - Integrated Inspection Report 07001151//2022004 ML23013A2122023-01-27027 January 2023 Acceptance Letter for Westinghouse License Transfer - Cac/Epid L-2022-LLM-0004 ML23026A3642023-01-26026 January 2023 Westinghouse, January 2023 Updated Integrated Safety Analysis Summary ML22354A0732023-01-19019 January 2023 Response to Westinghouse Revised Funding Instrument in Support of the Decommissioning Funding Plan ML22363A0152022-12-29029 December 2022 Westinghouse Electric Co - 60-Day Report Regarding the November 1, 2022, Incident Reported Under 10 CFR 70 Appendix a 24-Hr Report, Columbia Fuel Fabrication Facility (License No. SNM-1107, Docket No. 70-1151) ML22354A2912022-12-20020 December 2022 Application for Consent to Indirect Change of Control with Respect to a Materials License, Export Licenses, and Notification Regarding Other Approvals and Request for Threshold Determination ML22347A1162022-12-13013 December 2022 Westinghouse 2021-2022 Annual Groundwater Monitoring Report 2024-09-18
[Table view] |
Text
OFFICIAL USE ONLY - PROPRIETARY INFORMATION February 4, 2019 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066
SUBJECT:
DRAFT SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-16260-P/WCAP-16260-NP, REVISION 2, THE SPATIALLY CORRECTED INVERSE COUNT RATE (SCICR) METHOD FOR SUBCRITICAL REACTIVITY MEASUREMENT (EPID: L-2017-TOP-0064)
Dear Mr. Gresham:
By letter dated December 14, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17348B293), Westinghouse Electric Company (Westinghouse) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report (TR) WCAP-16260-P/WCAP-16260-NP, Revision 2, The Spatially Corrected Inverse Count Rate (SCICR) Method for Subcritical Reactivity Measurement. By letter dated August 9, 2018 (ADAMS Accession No. ML18207A226), the NRC issued its first round of the request for additional information (RAI) questions. By letter dated September 13, 2018 (ADAMS Accession No. ML18257A061), Westinghouse provided responses to these RAI questions. By letter dated September 24, 2018 (ADAMS Accession No. ML18263A197), the NRC issued its second round of RAI questions. By letter dated October 24, 2018 (ADAMS Accession No. ML18299A090),
Westinghouse provided responses to the second round of RAI responses.
Enclosed for Westinghouse review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR WCAP-16260-P/WCAP-16260-NP, Revision 2.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we believe that the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for you to comment on the proprietary aspects and provide any factual errors or clarity concerns contained in the SE. The final SE will be issued after making any necessary changes and a non-proprietary version will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
OFFICIAL USE ONLY - PROPRIETARY INFORMATION J. Gresham To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact Ekaterina Lenning at 301-415-3151.
Sincerely,
/RA/
Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation DOCKET 99902038
Enclosure:
Draft SE (Proprietary)
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
Pkg.- ML19022A047; Letter- ML19022A135; Enclosure- ML19022A110 *concurred via e-mail NRR-106 OFFICE NRR/DLP/PLPB/PM NRR/DLP/PLPB/LA NRR/DSS/SNPB/BC NRR/DLP/PLPB/BC NAME ELenning DHarrison* RLukes* DMorey DATE 01/22/2019 1/31/2019 2/04/2019 2/04/2019