Letter Sequence RAI |
|---|
EPID:L-2017-TOP-0064, Request for Additional Information for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement (Approved, Closed) |
|
MONTHYEARML18207A3592018-08-0909 August 2018 Non-Proprietary Enclosure 1 Request for Additional Information for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement Project stage: RAI ML18207A2172018-08-0909 August 2018 Request for Additional Information for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement Project stage: Request ML18207A2262018-08-0909 August 2018 Cover Letter Request for Additional Information Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement Project stage: RAI ML18257A0652018-09-13013 September 2018 Response to Request for Additional Information Westinghouse Electric Company WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: Response to RAI ML18257A0632018-09-13013 September 2018 Application for Withholding Proprietary Information from Public Disclosure Project stage: Request ML18257A0622018-09-13013 September 2018 Response to Request for Additional Information Westinghouse Electric Company WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: Response to RAI ML18263A1972018-09-24024 September 2018 Request for Additional Information Westinghouse Electric Co. WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement TR - Second Round Project stage: RAI ML19022A0162018-12-27027 December 2018 Attendees Closed Meeting 12-27-18 WCAP-16260-P Project stage: Request ML19022A0722019-01-28028 January 2019 Summary of Meeting with Westinghouse Electric Company to Discuss RAI Response Related to NRC Review of WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: RAI ML19022A1352019-02-0404 February 2019 Draft Safety Evaluation WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement. Project stage: Draft Approval ML19078A0482019-04-12012 April 2019 Cover Letter for the Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement. Project stage: Approval ML19077A2592019-04-12012 April 2019 Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Measurement Project stage: Request ML19078A0342019-04-12012 April 2019 Enclosure 1 - Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement. Project stage: Approval ML19078A0432019-04-12012 April 2019 Attachment 1 - Resolution of Comments Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate (Scicr) Method for Subcritical Reactivity Meas Project stage: Approval 2018-09-24
[Table View] |
Text
OFFICIAL USE ONLY - PROPRIETARY INFORMATION August 9, 2018 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION RE: WESTINGHOUSE ELECTRIC COMPANY WCAP-16260-P/WCAP-16260-NP, REVISION 2, THE SPATIALLY CORRECTED INVERSE COUNT RATE METHOD FOR SUBCRITICAL REACTIVITY MEASUREMENT TOPICAL REPORT (EPID L-2017-TOP-0064)
Dear Mr. Gresham:
By letter dated December 14, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17348B293), Westinghouse Electric Company (Westinghouse) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report (TR) WCAP-16260-P/WCAP-16260-NP, Revision 2, The Spatially Corrected Inverse Count Rate (SCICR) Method for Subcritical Reactivity Measurement. Upon the review of the TR the NRC staff has determined that additional information is needed to complete the review.
Enclosed are the NRC staff request for additional information (RAI) questions.
If you have any questions regarding the enclosed questions, please contact me at 301-415-3151.
Sincerely,
/RA/
Ekaterina Lenning, Project Manager Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation
Enclosure:
- 1. RAIs (Non-proprietary version)
- 2. RAIs (Proprietary version)
NOTICE: Enclosure 2 transmitted herewith contains proprietary information. When separated from Enclosure 2, this document is decontrolled.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
PKG ML18207A217 LTR ML18207A226 Non-Prop ML1207A359 Prop ML18207A362 *via e-mail NRR-106 OFFICE DLP/PLPB/PM DLP/PLPB/LA* DSS/SNPB/BC* DLP/PLPB/BC* DLP/PLPB/PM NAME ELenning DHarrison RLukes DMorey ELenning (LPerkins for)
DATE 7/26/2018 8/7/2018 8/8/2018 8/8/2018 8/9/2018