ML19078A048

From kanterella
Jump to navigation Jump to search

Cover Letter for the Final Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-16260-P/WCAP-16260-NP, Revision 2, the Spatially Corrected Inverse Count Rate Method for Subcritical Reactivity Measurement.
ML19078A048
Person / Time
Site: Westinghouse
Issue date: 04/12/2019
From: Dennis Morey
NRC/NRR/DLP/PLPB
To: Gresham J
Westinghouse
Lenning E, NRR/DLP/PLPB, 415-3151
Shared Package
ML19077A259 List:
References
EPID L-2017-TOP-0064
Download: ML19078A048 (3)


Text

OFFICIAL USE ONLY - PROPRIETARY INFORMATION April 12, 2019 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066

SUBJECT:

FINAL SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-16260-P/WCAP-16260-NP, REVISION 2, THE SPATIALLY CORRECTED INVERSE COUNT RATE METHOD FOR SUBCRITICAL REACTIVITY MEASUREMENT (EPID: L-2017-TOP-0064)

Dear Mr. Gresham:

By letter dated December 14, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17348B293), Westinghouse Electric Company (Westinghouse) submitted for the U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report (TR) WCAP-16260-P/WCAP-16260-NP, Revision 2, The Spatially Corrected Inverse Count Rate (SCICR) Method for Subcritical Reactivity Measurement. By letter dated August 9, 2018 (ADAMS Accession No. ML18207A226), the NRC issued its first round of the requests for additional information (RAI). By letter dated September 13, 2018 (ADAMS Accession No. ML18257A061), Westinghouse provided responses to these RAIs. By letter dated September 24, 2018 (ADAMS Accession No. ML18263A197), the NRC issued its second round of RAIs. By letter dated October 24, 2018 (ADAMS Accession No. ML18299A090),

Westinghouse provided responses to the second round of RAIs. By letter dated February 4, 2019, the NRC staff provided the draft safety evaluation (SE).

The enclosed final SE addresses the applicability of the WCAP-16260-P/WCAP-16260-NP, Revision 2, The Spatially Corrected Inverse Count Rate (SCICR) Method for Subcritical Reactivity Measurement, TR.

The NRC staff has found that WCAP-16260-P/WCAP-16260-NP, Revision 2, The Spatially Corrected Inverse Count Rate (SCICR) Method for Subcritical Reactivity Measurement, is acceptable for referencing in licensing applications provided that the limitations and conditions stipulated in the Section 4.0, conclusions in Section 5.0, and applicability defined in the enclosed NRC final SE are met along with the proper documentation.

NOTICE: Enclosure 2 and Attachment 2 transmitted herewith contains SUNSI. When separated from Enclosure 2 and Attachment 2, this transmittal document is decontrolled.

OFFICIAL USE ONLY - PROPRIETARY INFORMATION

OFFICIAL USE ONLY - PROPRIETARY INFORMATION J. Gresham Our acceptance applies only to material provided in the subject TRs. In accordance with the guidance provided on the NRC website, we request that Westinghouse publish accepted proprietary and non-proprietary versions of these TRs within three months of receipt of this letter.

The accepted versions shall incorporate this letter and the enclosed final SE after the title page.

Also, they must contain historical review information, including NRC RAIs and your responses.

The accepted versions shall include an "-A" (designating accepted) following the TRs identification symbol.

As an alternative to including the RAIs and RAI responses behind the title page, if changes to the TRs were provided to the NRC staff to support the resolution of RAI responses, and the NRC staff reviewed and approved those changes as described in the RAI responses, there are two ways that the accepted version can capture the RAIs:

1. The RAIs and RAI responses can be included as an Appendix to the accepted version.
2. The RAIs and RAI responses can be captured in the form of a table (inserted after the final SE) which summarizes the changes as shown in the approved version of the TRs. The table should reference the specific RAIs and RAI responses which resulted in any changes, as shown in the accepted version of the TRs.

If future changes to the NRCs regulatory requirements affect the acceptability of this TR, Westinghouse will be expected to revise the TR appropriately or justify its continued applicability for subsequent referencing. Licensees referencing this TR would be expected to justify its continued applicability or evaluate their plant using the revised TR.

Sincerely,

/RA Jason Paige for/

Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 99902038

Enclosures:

As stated OFFICIAL USE ONLY - PROPRIETARY INFORMATION

ML19077A259 (Package)

ML19078A048 (Letter)

ML19078A034 (Non-prop SE Enclosure 1)

ML19078A037 (Prop SE Enclosure 2)

ML19078A043 (Non-prop CR Attachment 1)

ML19078A045 (Prop CR Attachment 2) *concurrencevia e-mail NRR 106 OFFICE NRR/DLP/PLPB NRR/DLP/PLPB/LA* NRR/DSS/SNPB* NRR/DLP/PLPB/BC NAME ELenning DHarrison RLukes DMorey JPaige(for)