{{#Wiki_filter:EOP:E-1TITLE:LOSSOFREACTORORSECONDARY COOLANTREVllPAGE1of16ROCHESTER GASANDELECTRICCORPORATION GINNASTATIONCONTROLLED COPYNUMBERTECHNICAL REVIEWPORCREVIEWDATElv>>PLANTSUPERINTENDENT EFFECTIVE DATECATEGORY1.0REVIEWEDBY:,9304080163 930330"."PDRADOCK05000244P..""'PDR 1Pg'f EOP:E-1TLTLE:LOSSOFREACTORORSECONDARY COOLANTREVllPAGE2of16A.PURPOSE-Thisprocedure providesactionstorecoverfromalossofreactororsecondary coolant.B.ENTRYCONDITIONS/SYMPTOMS l.ENTRYCONDITIONS
{{#Wiki_filter:EOP: E-1 TITLE: LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 1 of 16 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE l v>>PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY: ,9304080163 930330"." PDRADOCK 05000244 P..""'PDR 1 P g'f EOP: E-1 TLTLE: LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 2 of 16 A.PURPOSE-This procedure provides actions to recover from a loss of reactor or secondary coolant.B.ENTRY CONDITIONS/SYMPTOMS l.ENTRY CONDITIONS
-Thisprocedure isenteredfrom:a.E-O,REACTORTRIPORSAFETYINJECTION, andFR-H.1,RESPONSETOLOSSOFSECONDARY HEATSINK,whenaPRZRPORVisstuckopenanditsblockvalvecannotbeclosed.b.E-O,REACTORTRIPORSAFETYINJECTION, withanyofthefollowing symptoms:
-This procedure is entered from: a.E-O, REACTOR TRIP OR SAFETY INJECTION, and FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, when a PRZR PORV is stuck open and its block valve can not be closed.b.E-O, REACTOR TRIP OR SAFETY INJECTION, with any of the following symptoms: high containment radiation, high containment pressure, or high containment recirculation sump level.c~E 0 g REACTOR TRI P OR SAFETY I N JECTION g ECA 2 1 g UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS, and FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, when RCS pressure is less than the shutoff head pressure of the RHR pumps or is decreasing.
highcontainment radiation, highcontainment
d.ES-1.1, SI TERMINATION, and FR-I.2, RESPONSE TO LOW PRESSURIZER LEVEL, if SI has to be reinitiated.
: pressure, orhighcontainment recirculation sumplevel.c~E0gREACTORTRIPORSAFETYINJECTIONgECA21gUNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS, andFR-H.1,RESPONSETOLOSSOFSECONDARY HEATSINK,whenRCSpressureislessthantheshutoffheadpressureoftheRHRpumpsorisdecreasing.
e.E-2, FAULTED STEAM GENERATOR ISOLATION, after identification and isolation of a faulted S/G.f ECA 0~2 g LOSS OF ALL AC POWER RECOVERY WITH S I REQUIRED I after normal injection mode conditions are established.
d.ES-1.1,SITERMINATION, andFR-I.2,RESPONSETOLOWPRESSURIZER LEVEL,ifSIhastobereinitiated.
g.ECA-1.2, LOCA OUTSIDE CONTAINMENT, when a LOCA outside containment is isolated.h.FR-C.1, RESPONSE TO INADEQUATE CORE COOLING, and FR-C.2, RESPONSE TO DEGRADED CORE COOLING, after core cooling has been r established.
e.E-2,FAULTEDSTEAMGENERATOR ISOLATION, afteridentification andisolation ofafaultedS/G.fECA0~2gLOSSOFALLACPOWERRECOVERYWITHSIREQUIREDIafternormalinjection modeconditions areestablished.
i.FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, if RCS pressure is less than all non-faulted S/G(s)pressure.j.FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, after secondary heat sink has been reestablished and all PRZR PORVs are close.  
g.ECA-1.2,LOCAOUTSIDECONTAINMENT, whenaLOCAoutsidecontainment isisolated.
h.FR-C.1,RESPONSETOINADEQUATE CORECOOLING,andFR-C.2,RESPONSETODEGRADEDCORECOOLING,aftercorecoolinghasbeenrestablished.
i.FR-H.1,RESPONSETOLOSSOFSECONDARY HEATSINK,ifRCSpressureislessthanallnon-faulted S/G(s)pressure.
j.FR-H.1,RESPONSETOLOSSOFSECONDARY HEATSINK,aftersecondary heatsinkhasbeenreestablished andallPRZRPORVsareclose.  


EOP:E-1TITLE:'LOSSOFREACTORORSECONDARY COOLANTREV:11PAGE3of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************CAUTIONIFRWSTLEVELDECREASES TOLESSTHAN28%,THENTHESISYSTEMSHOULDBEALIGNEDFORCOLDLEGRECIRCULATION USINGES-1.3,TRANSFERTOCOLDLEGRECIRCULATION, STEP1.NOTE'FOLDOUTpageshouldbeopenANDmonitored periodically.
EOP: E-1 TITLE: 'LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 3 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF RWST LEVEL DECREASES TO LESS THAN 28%, THEN THE SI SYSTEM SHOULD BE ALIGNED FOR COLD LEG RECIRCULATION USING ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, STEP 1.NOTE'FOLDOUT page should be open AND monitored periodically.
oCriticalSafetyFunctionStatusTreesshouldbemonitored.
o Critical Safety Function Status Trees should be monitored.(Refer to Appendix 1 for Red Path Summary.), o Conditions should be evaluated for Site Contingency Reporting (Refer to EPIP-1.0, GINNA STATION EVENT EVALUATION AND CLASSIFICATION)., o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+R/hr.*1 Monitor RCP Trip Criteria: a.RCP status-ANY RCP RUNNING b.SI pumps-AT LEAST TWO RUNNING c.RCS pressure minus maximum S/G pressure-LESS THAN 175 psig[400 psig adverse CNMT]d.Stop both RCPs a.Go to Step 2.b, Go to Step 2.c.Go to Step 2.  
(RefertoAppendix1forRedPathSummary.),
oConditions shouldbeevaluated forSiteContingency Reporting (RefertoEPIP-1.0, GINNASTATIONEVENTEVALUATION ANDCLASSIFICATION).,
oAdverseCNMTvaluesshouldbeusedwheneverCNMTpressureisgreaterthan4psigorCNMTradiation isgreaterthan10+R/hr.*1MonitorRCPTripCriteria:
a.RCPstatus-ANYRCPRUNNINGb.SIpumps-ATLEASTTWORUNNINGc.RCSpressureminusmaximumS/Gpressure-LESSTHAN175psig[400psigadverseCNMT]d.StopbothRCPsa.GotoStep2.b,GotoStep2.c.GotoStep2.  


EOPIE-1TITLE:LOSSOFREACTORORSECONDARY COOLANTREV:llPAGE4of16STEPACTION/EXPECTED RESPONSE~RESPONSENOTOBTAINED2CheckIfS/GSecondary SideIsIntact:oPressureinbothS/Gs-STABLEORINCREASING IFanyS/Gpressuredecreasing inanuncontrolled mannerORcompletely depressurized, THENverifyfaultedS/GisolatedunlessneededforRCScooldown:
EOP I E-1 TITLE: LOSS OF REACTOR OR SECONDARY COOLANT REV: ll PAGE 4 of 16 STEP ACTION/EXPECTED RESPONSE~RESPONSE NOT OBTAINED 2 Check If S/G Secondary Side Is Intact: o Pressure in both S/Gs-STABLE OR INCREASING IF any S/G pressure decreasing in an uncontrolled manner OR completely depressurized, THEN verify faulted S/G isolated unless needed for RCS cooldown: o Pressure in both S/Gs-GREATER THAN 100 PSIG~Steamlines
oPressureinbothS/Gs-GREATERTHAN100PSIG~Steamlines
~Feedlines IF NOT, THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step l.*****************************************CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).NOTE: TDAFW pump flow control valves fail open on loss of IA.*3 Monitor Intact S/G Levels: a.Narrow range level-GREATER THAN 58[258 adverse CNMT]b.Control feed flow to maintain narrow range level between 178[258 adverse CNMT]and 508 a.Maintain total feed flow greater than 200 gpm until narrow range level greater than 58[258 adverse CNMT]in at least one S/G.b.IF narrow range level in any S/G continues to increase in an uncontrolled manner, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.
~Feedlines IFNOT,THENgotoE-2,FAULTEDSTEAMGENERATOR ISOLATION, Stepl.*****************************************CAUTIONIFCSTLEVELDECREASES TOLESSTHAN5FEET,THENALTERNATE WATERSOURCESFORAFWPUMPSWILLBENECESSARY (REFERTOER-AFW.1, ALTERNATE WATERSUPPLYTOAFWPUMPS).NOTE:TDAFWpumpflowcontrolvalvesfailopenonlossofIA.*3MonitorIntactS/GLevels:a.Narrowrangelevel-GREATERTHAN58[258adverseCNMT]b.Controlfeedflowtomaintainnarrowrangelevelbetween178[258adverseCNMT]and508a.Maintaintotalfeedflowgreaterthan200gpmuntilnarrowrangelevelgreaterthan58[258adverseCNMT]inatleastoneS/G.b.IFnarrowrangelevelinanyS/Gcontinues toincreaseinanuncontrolled manner,THENgotoE-3,STEAMGENERATOR TUBERUPTURE,Stepl.
W 1 N EOP!E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 5 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Check Secondary Radiation Levels-NORMAL o Steamline radiation monitor (R-31 and R-32)o Request HP sample S/Gs for activity IF steamline radiation monitors NOT available, THEN dispatch AO to locally check steamline radiation.
W1N EOP!E-1LOSSOFREACTORORSECONDARY COOLANTREV11PAGE5of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED4CheckSecondary Radiation Levels-NORMALoSteamline radiation monitor(R-31andR-32)oRequestHPsampleS/GsforactivityIFsteamline radiation monitorsNOTavailable, THENdispatchAOtolocallychecksteamline radiation.
IF abnormal radiation levels detected in any S/G, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.*****************************************CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 5B).*5 Monitor PRZR PORV Status: a.Power to PORV block valves-AVAILABLE b.PORVs-CLOSED a.Restore power to block valves unless block valve was closed to isolate an open PORV:~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C b.IF PRZR pressure less than 2335 psig, THEN manually close PORVs.c.Block valves-AT LEAST ONE OPEN IF any PORV can NOT be closed, THEN manually close its block valve.IF block valve can NOT be closed, THEN dispatch AO to locally check breaker.~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C c.Open one block valve unless it was closed to isolate an open PORV.
IFabnormalradiation levelsdetectedinanyS/G,THENgotoE-3,STEAMGENERATOR TUBERUPTURE,Stepl.*****************************************CAUTIONIFANYPRZRPORVOPENSBECAUSEOFHIGHPRZRPRESSURE, ITSHOULDBECLOSEDAFTERPRESSUREDECREASES TOLESSTHAN2335PSIG(REFERTOSTEP5B).*5MonitorPRZRPORVStatus:a.PowertoPORVblockvalves-AVAILABLE b.PORVs-CLOSEDa.RestorepowertoblockvalvesunlessblockvalvewasclosedtoisolateanopenPORV:~MOV-515,MCCCposition6C~MOV-516,MCCDposition6Cb.IFPRZRpressurelessthan2335psig,THENmanuallyclosePORVs.c.Blockvalves-ATLEASTONEOPENIFanyPORVcanNOTbeclosed,THENmanuallycloseitsblockvalve.IFblockvalvecanNOTbeclosed,THENdispatchAOtolocallycheckbreaker.~MOV-515,MCCCposition6C~MOV-516,MCCDposition6Cc.OpenoneblockvalveunlessitwasclosedtoisolateanopenPORV.
K EOP!E-1 TITLE LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 6 of 16 ,STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
K EOP!E-1TITLELOSSOFREACTORORSECONDARY COOLANTREVllPAGE6of16,STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************CAUTIONIFOFFSITEPOWERISLOSTAFTERSIRESET,THENSELECTEDSWPUMPSANDONECCWPUMPWILLAUTOSTARTONEMERGENCY D/G.MANUALACTIONWILLBEREQUIREDTORESTARTSAFEGUARDS EQUIPMENT.
6 Reset SZ 7 Reset CI: a.Depress CI reset pushbutton b., Verify annunciator A-26, CNMT ISOLATION-EXTINGUISHED b.Perform the following:
6ResetSZ7ResetCI:a.DepressCIresetpushbutton b.,Verifyannunciator A-26,CNMTISOLATION
1)Reset SI.2)Depress CI reset pushbutton.
-EXTINGUISHED b.Performthefollowing:
8.Verify Adequate SW Flow: a.Check at least two SW pumps RUNNING b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN perform the following:
1)ResetSI.2)DepressCIresetpushbutton.
1)Ensure SW isolation.
8.VerifyAdequateSWFlow:a.CheckatleasttwoSWpumpsRUNNINGb.DispatchAOtoestablish normalshutdownalignment (RefertoAttachment SD-1)a.ManuallystartSWpumpsaspowersupplypermits(258kweach).IFlessthantwoSWpumpsrunning,THENperformthefollowing:
2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)3)Go to Step 10.  
1)EnsureSWisolation.
2)DispatchAOtoestablish normalshutdownalignment (RefertoAttachment SD-1)3)GotoStep10.  


EOPIE-1LOSSOFREACTORORSECONDARY COOLANTREV:11PAGE7of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED9Establish IAtoCNMT:a.Verifynon-safeguards bussesenergized fromoffsitepoweroBus13normalfeed-CLOSED-OR-oBus15normalfeed-CLOSEDb,VerifyturbinebuildingSWisolation valves-OPEN~MOV-4613andMOV-4670~MOV-4614andMOV-4664c.Verifyatleasttwoaircompressors
EOP I E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 7 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 9 Establish IA to CNMT: a.Verify non-safeguards busses energized from offsite power o Bus 13 normal feed-CLOSED-OR-o Bus 15 normal feed-CLOSED b, Verify turbine building SW isolation valves-OPEN~MOV-4613 and MOV-4670~MOV-4614 and MOV-4664 c.Verify at least two air compressors
-RUNNINGd.CheckIAsupply:oPressure-GREATERTHAN60PSIGoPressure-STABLEORINCREASING e.ResetbothtrainsofXYrelaysforIAtoCNMTAOV-5392f.VerifyIAtoCNMTAOV-5392-OPENa.Performthefollowing:
-RUNNING d.Check IA supply: o Pressure-GREATER THAN 60 PSIG o Pressure-STABLE OR INCREASING e.Reset both trains of XY relays for IA to CNMT AOV-5392 f.Verify IA to CNMT AOV-5392-OPEN a.Perform the following:
1)Closenon-safeguards bustiebreakers:
1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie'Bus 15 to Bus 16 tie 2)Verify adequate emergency D/G capacity to run air compressors (75 kw each).IF NOT, THEN evaluate if CNMT'ECIRC fans should be stopped (Refer to Attachment CNMT RECIRC FANS).3)WHEN bus 15 restored, THEN reset control room lighting.b.Manually align valves.c.Manually start air compressors as power supply permits (75 kw each).IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.
~Bus13toBus14tie'Bus15toBus16tie2)Verifyadequateemergency D/Gcapacitytorunaircompressors (75kweach).IFNOT,THENevaluateifCNMT'ECIRCfansshouldbestopped(RefertoAttachment CNMTRECIRCFANS).3)WHENbus15restored, THENresetcontrolroomlighting.
d.Perform the following:
b.Manuallyalignvalves.c.Manuallystartaircompressors aspowersupplypermits(75kweach).IFaircompressors canNOTbestarted,THENdispatchAOtolocallyresetcompressors asnecessary.
1)Continue attempts to restore IA (Refer to AP-IA.1, LOSS OF INSTRUMENT AIR).2)Continue with Step 10.WHEN IA restored, THEN do Steps 9e and f.
d.Performthefollowing:
1)ContinueattemptstorestoreIA(RefertoAP-IA.1,LOSSOFINSTRUMENT AIR).2)ContinuewithStep10.WHENIArestored, THENdoSteps9eandf.
f)
f)
E-l.LOSSOFREACTORORSECONDARY COOLANTREV:11PAGE8of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED10CheckNormalPowerAvailable ToChargingPumps:oBus14normalfeedbreaker-'CLOSEDoBus16normalfeedbreaker-CLOSEDVerifyadequateemergency D/Gcapacitytorunchargingpumps(75kweach).IFNOT,THENevaluateifCNMTRECIRCfanscanbestopped(RefertoAttachment CNMTRECIRCFANS)..  
E-l.LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 8 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 10 Check Normal Power Available To Charging Pumps: o Bus 14 normal feed breaker-'CLOSED o Bus 16 normal feed breaker-CLOSED Verify adequate emergency D/G capacity to run charging pumps (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans can be stopped (Refer to Attachment CNMT RECIRC FANS)..  


EOP:E-1LOSSOFREACTORORSECONDARY COOLANTREV11PAGE9of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDllCheckIfChargingFlowHasBeenEstablished:
EOP: E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 9 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED ll Check If Charging Flow Has Been Established:
a.Chargingpumps-ANYRUNNINGa.Performthefollowing:
a.Charging pumps-ANY RUNNING a.Perform the following:
1)IFCCWflowislosttoany.RCPthermalbarrierORanyRCP¹1sealoutlettemperature offscalehigh,THENdispatchAOwithkeytoRWSTgatetoclosesealin)ection needlevalve(s)toaffectedRCP:~V-300AforRCPA~V-300BforRCPBb.ChargingpumpsuctionalignedtoRWST'LCV-112B-OPENoLCV-112C-CLOSED2)EnsureHCV-142open,demandat0%.b.Manuallyalignvalvesasnecessary.
1)IF CCW flow is lost to any.RCP thermal barrier OR any RCP¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal in)ection needle valve(s)to affected RCP:~V-300A for RCP A~V-300B for RCP B b.Charging pump suction aligned to RWST'LCV-112B-OPEN o LCV-112C-CLOSED 2)Ensure HCV-142 open, demand at 0%.b.Manually align valves as necessary.
IFLCV-112BcanNOTbeopened,THENperformthefollowing:
IF LCV-112B can NOT be opened, THEN perform the following:
1)VerifychargingpumpANOTrunningandplaceinPULLSTOP.c.Startchargingpumpsasnecessary andadjustchargingflowtorestorePRZRlevel2)DispatchAOtolocallyopenmanualchargingpumpsuctionfromRWST(V-358locatedinchargingpumproom).3)WHENV-358open,THENdirectAOtocloseV-268toisolatechargingpumpsBandCfromVCT(V-268locatedinchargingpumproom).
1)Verify charging pump A NOT running and place in PULL STOP.c.Start charging pumps as necessary and adjust charging flow to restore PRZR level 2)Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).3)WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).
lp',~
lp',~
EOP:E-1T1TLE:LOSSOFREACTORORSECONDARY COOLANTREV11PAGE10of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED12CheckIfSIShouldBeTerminated:
EOP: E-1 T1TLE: LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 10 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 12 Check If SI Should Be Terminated:
a.RCSpressure:
a.RCS pressure: o Pressure-GREATER THAN 1625 psig[1825 psig adverse CNMT]o Pressure-STABLE OR INCREASING a.Do NOT stop SI pumps.Go to Step 14.b.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING b.Do NOT stop SI pumps.Go to Step 14.c.Secondary heat sink: o Total feed flow to intact S/Gs-GREATER THAN 200 GPM-OR-c.IF neither condition satisfied, THEN do NOT stop SI pumps.Go to Step 14.o Narrow range level in at least one intact S/G-GREATER THAN 5%[25%adverse CNMT]d.PRZR level-GREATER THAN 5%[30%adverse CNMT]d;Do NOT stop SI pumps'erform the following:
oPressure-GREATERTHAN1625psig[1825psigadverseCNMT]oPressure-STABLEORINCREASING a.DoNOTstopSIpumps.GotoStep14.b.RCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING b.DoNOTstopSIpumps.GotoStep14.c.Secondary heatsink:oTotalfeedflowtointactS/Gs-GREATERTHAN200GPM-OR-c.IFneithercondition satisfied, THENdoNOTstopSIpumps.GotoStep14.oNarrowrangelevelinatleastoneintactS/G-GREATERTHAN5%[25%adverseCNMT]d.PRZRlevel-GREATERTHAN5%[30%adverseCNMT]d;DoNOTstopSIpumps'erform thefollowing:
1)IF normal PRZR spray available, THEN try to stabilize RCS pressure with PRZR spray.2)Go to Step 14.  
1)IFnormalPRZRsprayavailable, THENtrytostabilize RCSpressurewithPRZRspray.2)GotoStep14.  


EOPsE-1LOSSOFREACTORORSECONDARY COOLANTREV:llPAGE11of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED13GoToES-1.1,SITERMINATION/
EOP s E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV: ll PAGE 11 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Go To ES-1.1, SI TERMINATION/
Step1*14MonitorIfCNMTSprayShouldBeStopped:a.CNMTspraypumps-RUNNINGb.Checkthefollowing:
Step 1*14 Monitor If CNMT Spray Should Be Stopped: a.CNMT spray pumps-RUNNING b.Check the following:
oCNMTpressure-LESSTHAN4PSIGa.GotoStep15.b.ContinuewithStep15.WHENBOTHconditions satisfied, THENdo'Steps14cthroughf.oSodiumhydroxide tanklevel-LESSTHAN55%c.ResetCNMTsprayd.CheckNaOHtankoutletvalves-CLOSED~AOV-836A~AOV-836Bd;PlaceNaOHtankoutletvalvecontrollers toMANUALandclosevalves.e.StopCNMTspraypumpsandplaceinAUTOf.CloseCNMTspraypumpdischarge valves~MOV-860A~MOV-860B~MOV-860C~MOV~860D C
o CNMT pressure-LESS THAN 4 PSIG a.Go to Step 15.b.Continue with Step 15.WHEN BOTH conditions satisfied, THEN do'Steps 14c through f.o Sodium hydroxide tank level-LESS THAN 55%c.Reset CNMT spray d.Check NaOH tank outlet valves-CLOSED~AOV-836A~AOV-836B d;Place NaOH tank outlet valve controllers to MANUAL and close valves.e.Stop CNMT spray pumps and place in AUTO f.Close CNMT spray pump discharge valves~MOV-860A~MOV-860B~MOV-860C~MOV~860D C
EOP:E-1TITLE.LOSSOFREACTORORSECONDARY COOLANTREV:11PAGE12of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************,CAUTIONoIFOFFSITEPOWERISLOSTAFTERSIRESET,THENSELECTEDSWPUMPSANDONECCWPUMPWILLAUTOSTARTONEMERGENCY D/G.MANUALACTIONWILLBEREQUIREDTORESTARTSAFEGUARDS EQUIPMENT.
EOP: E-1 TITLE.LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 12 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************, CAUTION o IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
oRCSPRESSURESHOULDBEMONITORED.
o RCS PRESSURE SHOULD BE MONITORED.
IFRCSPRESSUREDECREASES TOLESSTHAN250PSIG[465PSIGADVERSECNMT],THENTHERHRPUMPSMUSTBEMANUALLYRESTARTED TOSUPPLYWATERTOTHERCS.*15MonitorIfRHRPumpsShould.BeStopped:a.CheckRCSpressure:
IF RCS PRESSURE DECREASES TO LESS THAN 250 PSIG[465 PSIG ADVERSE CNMT], THEN THE RHR PUMPS MUST BE MANUALLY RESTARTED TO SUPPLY WATER TO THE RCS.*15 Monitor If RHR Pumps Should.Be Stopped: a.Check RCS pressure: 1)Pressure-GREATER THAN 250 psig[465 psig adverse CNMT]2)RCS pressure-STABLE OR~INCREASING b.Stop RHR pumps and place in AUTO 1)Go to Step 17.2)Go to Step 16.16 Check RCS And S/G Pressures a.Check pressures in both S/Gs STABLE OR INCREASING a.Return to Step 1.b.Check pressures in both S/Gs-GREATER THAN 100 PSIG c.Check RCS pressure-STABLE OR DECREASING b.Monitor RCS pressure.IF RCS pressure does NOT increase after faulted S/G dryout, THEN go to Step 17.c.Return to Step l.  
1)Pressure-GREATERTHAN250psig[465psigadverseCNMT]2)RCSpressure-STABLEOR~INCREASING b.StopRHRpumpsandplaceinAUTO1)GotoStep17.2)GotoStep16.16CheckRCSAndS/GPressures a.Checkpressures inbothS/GsSTABLEORINCREASING a.ReturntoStep1.b.Checkpressures inbothS/Gs-GREATERTHAN100PSIGc.CheckRCSpressure-STABLEORDECREASING b.MonitorRCSpressure.
IFRCSpressuredoesNOTincreaseafterfaultedS/Gdryout,THENgotoStep17.c.ReturntoStepl.  


EOP:E-1TLTLE:LOSSOFREACTORORSECONDARY COOLANTREV:11PAGE13of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED17CheckIfEmergency D/GsShouldBeStopped:a.VerifyACemergency bussesenergized byoffsitepower:oEmergency D/GoutputbreakersOPENoACemergency busvoltageGREATERTHAN420VOLTSoACemergency busnormalfeedbreakers-CLOSEDa.Performthefollowing:
EOP: E-1 TLTLE: LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 13 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN o AC emergency bus voltage GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED a.Perform the following:
1)Closenon-safeguards bustiebreakersasnecessary:
1)Close non-safeguards bus tie breakers as necessary:
~Bus13toBus14tie~Bus15toBus16tie2)Placethefollowing pumpsinPULLSTOP'EHpumps~Turninggearoilpump~HPsealoilbackuppump3)Ensurecondenser steamdumpmodecontrolinMANUAL.4)RestorepowertoMCCs:~AfromBus13~BfromBus15~EfromBus15'FfromBus155)WHENbus15restored, THENresetcontrolroomlightingbreaker.6)RefertoAttachment SI/UVforotherequipment lostwithlossofoffsitepower.7)Trytorestoreoffsitepower(RefertoER-ELEC.1, RESTORATION OFOFFSITEPOWER).b.Stopanyunloadedemergency D/G~andplaceinstandby(RefertoAttachment D/GSTOP)  
~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Place the following pumps in PULL STOP'EH pumps~Turning gear oil pump~HP seal oil backup pump 3)Ensure condenser steam dump mode control in MANUAL.4)Restore power to MCCs:~A from Bus 13~B from Bus 15~E from Bus 15'F from Bus 15 5)WHEN bus 15 restored, THEN reset control room lighting breaker.6)Refer to Attachment SI/UV for other equipment lost with loss of offsite power.7)Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).b.Stop any unloaded emergency D/G~and place in standby (Refer to Attachment D/G STOP)  


EOPE-1LOSSOFREACTORORSECONDARY COOLANTREV'1PAGE14of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED18VerifyCNMTSumpRecirculation Capability:
EOP E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV'1 PAGE 14 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Verify CNMT Sump Recirculation Capability:
a.CheckRHRsystem:1)Poweravailable toemergency ACbussesandMCCsrequiredforCNMTsumprecirculation oBus14andbus18ENERGIZED a.Restore'powertoatleastonetrainofemergency ACbusses.IFatleastonetrainofcoldlegrecirculation capability canNOTbeverified, THENgotoECA-1.1,LOSSOFEMERGENCY COOLANTRECIRCULATION, Step1.oMCCC-ENERGIZED oBus16andbus17-ENERGIZED oMCCD-ENERGIZED 2)RHRpumpsandvalvesOPERABLEb.CheckSWpumps-ATLEAST2PUMPSAVAILABLE c.DispatchAOtocheckAUXBLDGsub-basement forRHRsystemleakage(AUXBLDGsub-basement keymay'berequired) b.Attempttorestoreatleast2SWpumpstooperable.
a.Check RHR system: 1)Power available to emergency AC busses and MCCs required for CNMT sump recirculation o Bus 14 and bus 18 ENERGIZED a.Restore'power to at least one train of emergency AC busses.IF at least one train of cold leg recirculation capability can NOT be verified, THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step 1.o MCC C-ENERGIZED o Bus 16 and bus 17-ENERGIZED o MCC D-ENERGIZED 2)RHR pumps and valves OPERABLE b.Check SW pumps-AT LEAST 2 PUMPS AVAILABLE c.Dispatch AO to check AUX BLDG sub-basement for RHR system leakage (AUX BLDG sub-basement key may'be required)b.Attempt to restore at least 2 SW pumps to operable.IF only 1 SW pump available, THEN refer to Attachment MIN SW for additional guidance.c.IF any RHR pump seal leakage indicated, THEN leakage should.be evaluated and isolated if necessary.
IFonly1SWpumpavailable, THENrefertoAttachment MINSWforadditional guidance.
II E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 15 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 19 Evaluate Plant Status: a.Check auxiliary building radiation-NORMAL~Plant vent iodine (R-10B)~Plant vent particulate (R-13)~Plant vent gas (R-14)~CCW liquid monitor (R-17)~LTDN line monitor (R-9)~CHG pump room (R-4)b.Direct HP to obtain following samples:~RCS boron~RCS activity~CNMT hydrogen~CNMT sump boron~BASTs,boron a.Notify HP and refer to appropriate AR-RMS procedure.
c.IFanyRHRpumpsealleakageindicated, THENleakageshould.beevaluated andisolatedifnecessary.
IF the cause is a loss of RCS inventory outside CNMT, THEN go to.ECA-1.2, LOCA OUTSIDE CONTAINMENT, Step 1.c.Verify adequate Rx head cooling: 1)Check IA to CNMT-AVAILABLE 2)Verify at least one control rod shroud fan-RUNNING 3)Verify, one Rx compartment cooling fan-RUNNING 1)Go to Step 20.2)Manually start one fan as power supply permits (45 kw)3)Perform the following:
II E-1LOSSOFREACTORORSECONDARY COOLANTREV11PAGE15of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED19EvaluatePlantStatus:a.Checkauxiliary buildingradiation
o Dispatch AO to reset UV relays at MCC C and MCC D o Manually start one fan as power supply permits'(23 kw)  
-NORMAL~Plantventiodine(R-10B)~Plantventparticulate (R-13)~Plantventgas(R-14)~CCWliquidmonitor(R-17)~LTDNlinemonitor(R-9)~CHGpumproom(R-4)b.DirectHPtoobtainfollowing samples:~RCSboron~RCSactivity~CNMThydrogen~CNMTsumpboron~BASTs,boron a.NotifyHPandrefertoappropriate AR-RMSprocedure.
IFthecauseisalossofRCSinventory outsideCNMT,THENgoto.ECA-1.2, LOCAOUTSIDECONTAINMENT, Step1.c.VerifyadequateRxheadcooling:1)CheckIAtoCNMT-AVAILABLE 2)Verifyatleastonecontrolrodshroudfan-RUNNING3)Verify,oneRxcompartment coolingfan-RUNNING1)GotoStep20.2)Manuallystartonefanaspowersupplypermits(45kw)3)Performthefollowing:
oDispatchAOtoresetUVrelaysatMCCCandMCCDoManuallystartonefanaspowersupplypermits'(23kw)  


EOP:E-1LOSSOFREACTORORSECONDARY COOLANTREV11PAGE16of16STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED20CheckIfRCSCooldownAndDepressurization IsRequired:
EOP: E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 16 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 20 Check If RCS Cooldown And Depressurization Is Required: a.RCS pressure-GREATER THAN 250 psig[465 psig adverse CNMT]b.Go to ES-1.2, POST LOCA COOLDOWN AND DEPRESSURIZATION, Step 1 a.IF RHR pump flow greater than 475 gpm, THEN go to Step 21, 21 Check If Transfer To Cold Leg Recirculation Is Required: a.RWST level-LESS THAN 28%b.Go to ES-1;3, TRANSFER TO COLD LEG RECIRCULATION, Step 1 a.Return to Step 18.-END-I EOP: LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 1 of 1 E-1 APPENDIX LIST TITIZ PAGES 1)RED PATH
a.RCSpressure-GREATERTHAN250psig[465psigadverseCNMT]b.GotoES-1.2,POSTLOCACOOLDOWNANDDEPRESSURIZATION, Step1a.IFRHRpumpflowgreaterthan475gpm,THENgotoStep21,21CheckIfTransferToColdLegRecirculation IsRequired:
a.RWSTlevel-LESSTHAN28%b.GotoES-1;3,TRANSFERTOCOLDLEGRECIRCULATION, Step1a.ReturntoStep18.-END-I EOP:LOSSOFREACTORORSECONDARY COOLANTREV:11PAGE1of1E-1APPENDIXLISTTITIZPAGES1)REDPATHSUMMARY2)FIGUREMINSUBCOOLING 3)ATTACHMENT CNMTRECIRC4)ATTACHMENT D/GSTOP5)ATTACHMENT SD-16)ATTACHMENT SI/UV7)ATTACHMENT MINSW8)ATTACHMENT AUXBLDGSW9)ATTACHMENT SWLOADSINCNMT10)FOLDOUT


EOPsE-1T1TLE0LOSSOFREACTORORSECONDARY COOLANTREVllPAGE1of1REDPATHSUMMARYa.SUBCRITICALITY
==SUMMARY==
-Nuclearpowergreaterthan54b.CORECOOLING-CoreexitT/Csgreaterthan1200'F-OR-CoreexitT/Csgreaterthan700'FANDRVLISlevel(noRCPs)lessthan'34[464adverseCNMT]c.HEATSINK-NarrowrangelevelinallS/Gslessthan54[254adverseCNMT]ANDtotalfeedwater flowlessthan200gpmd.INTEGRITY
2)FIGURE MIN SUBCOOLING 3)ATTACHMENT CNMT RECIRC 4)ATTACHMENT D/G STOP 5)ATTACHMENT SD-1 6)ATTACHMENT SI/UV 7)ATTACHMENT MIN SW 8)ATTACHMENT AUX BLDG SW 9)ATTACHMENT SW LOADS IN CNMT 10)FOLDOUT
-Coldlegtemperatures decreasegreaterthan100'Finlast60minutesANDRCScoldlegtemperature lessthan285'Fe.CONTAINMENT
-CNMTpressuregreaterthan60psig


EOP.E-1TITLE:LOSSOFREACTORORSECONDARY COOLANTREVllPAGE1of1FIGUREMINSUBCOOLING NOTE:Subcooling Margin=Saturation Temperature FromFigureBelow[-]CoreExitT/CIndication RC25002400230022002100200019001800170016001500140013001200110010009008007006005004003002001000SPRESSURE(PSIG)RCSPRESSUREINCREMENTS 20PSIGSUBCOOLED REGIONADVEECNMTRSNORMALCNMTINADEQUATE SUBCOOLING REGIONTEMPERATURE INCREMENTS 10'200250300350400450500550600650700COREEXITSATURATION TEMPERATURE
EOP s E-1 T1TLE0 LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 1 of 1 RED PATH
 
==SUMMARY==
a.SUBCRITICALITY
-Nuclear power greater than 54 b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than'34[464 adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[254 adverse CNMT]AND total feedwater flow less than 200 gpm d.INTEGRITY-Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT
-CNMT pressure greater than 60 psig
 
EOP.E-1 TITLE: LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below[-]Core Exit T/C Indication RC 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 S PRESSURE (PSIG)RCS PRESSURE INCREMENTS 20 PSIG SUBCOOLED REGION ADVE E CNMT RS NORMAL CNMT INADEQUATE SUBCOOLING REGION TEMPERATURE INCREMENTS 10'200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEMPERATURE
('F)  
('F)  


EOP:E-1LOSSOFREACTORORSECONDARY COOLANTREV11PAGE1of1FOLDOUTPAGE1.SIREINITIATION CRITERIAIFEITHERcondition listedbelowoccurs,THENmanuallyoperateSIpumpsasnecessary:
EOP: E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 1 of 1 FOLDOUT PAGE 1.SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN manually operate SI pumps as necessary:
oRCSsubcooling basedoncoreexitT/Cs-LESSTHANO'FUSINGFIGUREMINSUBCOOLING OR-oPRZRlevel-CHARGINGCANNOTCONTROLLEVELGREATERTHAN5%[30%adverseCNMT]2~SITERMINATION CRITERIAIFALLconditions listedbelowoccur,THENgotoES-1.1,SITERMINATION, Step1:a.RCSsubcooling basedoncoreexitT/Cs-GREATERTHAN0FUSINGFIGUREMINSUBCOOLING b.TotalfeedflowtointactS/Gs-GREATERTHAN200GPMOR-NarrowrangelevelinatleastoneintactS/G-GREATERTHAN5%[25%adverseCNMT]c.RCSpressure:
o RCS subcooling based on core exit T/Cs-LESS THAN O'F USING FIGURE MIN SUBCOOLING OR-o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%[30%adverse CNMT]2~SI TERMINATION CRITERIA IF ALL conditions listed below occur, THEN go to ES-1.1, SI TERMINATION, Step 1: a.RCS subcooling based on core exit T/Cs-GREATER THAN 0 F USING FIGURE MIN SUBCOOLING b.Total feed flow to intact S/Gs-GREATER THAN 200 GPM OR-Narrow range level in at least one intact S/G-GREATER THAN 5%[25%adverse CNMT]c.RCS pressure: o GREATER THAN 1625 PSIG[1825 psig adverse CNMT]o STABLE OR INCREASING d.PRZR level-GREATER THAN 5%[30%adverse CNMT]3.SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2, FAULTED S/G ISOLATION, Step 1.4.COLD LEG RECIRCULATION SWITCHOVER CRITERION IF RWST level decreases to less than 28%, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step.l.5.AFW SUPPLY SWITCHOVER CRITERION IF CST'evel decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.l, ALTERNATE WATER SUPPLY TO AFW PUMPS).6.E-3 TRANSITION CRITERIA IF any S/G'level increases in an uncontrolled manner or any S/G has abnormal radiation, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.  
oGREATERTHAN1625PSIG[1825psigadverseCNMT]oSTABLEORINCREASING d.PRZRlevel-GREATERTHAN5%[30%adverseCNMT]3.SECONDARY INTEGRITY CRITERIAIFanyS/Gpressureisdecreasing inanuncontrolled manneroriscompletely depressurized ANDhasnotbeenisolated, THENgotoE-2,FAULTEDS/GISOLATION, Step1.4.COLDLEGRECIRCULATION SWITCHOVER CRITERION IFRWSTleveldecreases tolessthan28%,THENgotoES-1.3,TRANSFERTOCOLDLEGRECIRCULATION, Step.l.5.AFWSUPPLYSWITCHOVER CRITERION IFCST'eveldecreases tolessthan5feet,THENswitchtoalternate AFWwatersupply(RefertoER-AFW.l, ALTERNATE WATERSUPPLYTOAFWPUMPS).6.E-3TRANSITION CRITERIAIFanyS/G'levelincreases inanuncontrolled manneroranyS/Ghasabnormalradiation, THENgotoE-3,STEAMGENERATOR TUBERUPTURE,Stepl.  


EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE1of38ROCHESTER GASANDELECTRICCORPORATION GINNASTATIONCONTROLLED COPYNUMBERTECHNICAL REVIEW1PORCREVIEWDATEk'LANTSUPERINTENDENT EFFECTIVDATECATEGORY1.0REVIEWEDBY:
EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 1 of 38 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW 1 PORC REVIEW DATE k'LANT SUPERINTENDENT EFFECTIV DATE CATEGORY 1.0 REVIEWED BY:
0fICKcAaJpP,*t EOP:E-3JITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE2of38A.PURPOSE-Thisprocedure providesactionstoterminate leakageofreactorcoolantintothesecondary systemfollowing asteamgenerator tuberupture(SGTR),thisprocedure shouldalsobeusedforaSGTRinoneS/GandafaultintheotherS/G.B.ENTRYCONDITIONS/SYMPTOMS l.ENTRYCONDITIONS
0 f IC K c A aJ pP,*t EOP: E-3 JITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 2 of 38 A.PURPOSE-This procedure provides actions to terminate leakage of reactor coolant into the secondary system following a steam generator tube rupture (SGTR), this procedure should also be used for a SGTR in one S/G and a fault in the other S/G.B.ENTRY CONDITIONS/SYMPTOMS l.ENTRY CONDITIONS
-Thisprocedure isenteredfrom:a.E-O,REACTORTRIPORSAFETYINJECTION, whencondenser airejectorradiation orblowdownradiation isabnormal, orb~E0gREACTORTRIPORSAFETYINJECTION/
-This procedure is entered from: a.E-O, REACTOR TRIP OR SAFETY INJECTION, when condenser air ejector radiation or blowdown radiation is abnormal, or b~E 0 g REACTOR TRIP OR SAFETY INJECTION/
E1/LOSSOFREACTORORSECONDARY COOLANTgE-2,FAULTEDSTEAMGENERATOR ISOLATION, andFRHE3RESPONSETOSTEAMGENERATOR HIGHLEVELSwhensecondary radiation isabnormal, orc.E-O,REACTORTRIPORSAFETYINJECTION/
E 1/LOSS OF REACTOR OR SECONDARY COOLANT g E-2, FAULTED STEAM GENERATOR ISOLATION, and FR HE 3 RESPONSE TO STEAM GENERATOR HIGH LEVELS when secondary radiation is abnormal, or c.E-O, REACTOR TRIP OR SAFETY INJECTION/
E1gLOSSOFREACTORORSECONDARY COOLANTgES1~2gPOSTLOCACOOLDOWNANDDEPRESSURI ZATIONgECA3~3gSGTRWITHOUTPRESSURIZERPRESSURECONTROLSwhenanintactS/Gnarrowrangelevelincreases inanuncontrolled manner.dECA3~3~SGTRWITHOUTPRESSURIZERPRESSURECONTROL/whenpressurizer pressurecontrolisrestored.
E 1 g LOSS OF REACTOR OR SECONDARY COOLANT g ES 1~2 g POST LOCA COOLDOWN AND DEPRESSURI ZATION g ECA 3~3 g SGTR WITHOUT PRESSURI ZER PRESSURE CONTROLS when an intact S/G narrow range level increases in an uncontrolled manner.d ECA 3~3~SGTR WITHOUT PRESSURI ZER PRESSURE CONTROL/when pressurizer pressure control is restored.e.E-1 series FOLDOUT page'whenever either S/G level increases in an uncontrolled manner or either S/G has abnormal radiation.  
e.E-1seriesFOLDOUTpage'whenever eitherS/Glevelincreases inanuncontrolled manneroreitherS/Ghasabnormalradiation.  
~A$r a.a EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 3 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o FOLDOUT page should be open AND monitored periodically.
~A$ra.a EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE3of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDNOTE:oFOLDOUTpageshouldbeopenANDmonitored periodically.
o Critical Safety Function Status Trees should be monitored (Refer to Appendix 1 for Red Path Summary).o Personnel should be available for sampling during this procedure.
oCriticalSafetyFunctionStatusTreesshouldbemonitored (RefertoAppendix1forRedPathSummary).
o Conditions should be evaluated for Site Contingency Reporting (EPIP-1.0, GINNA STATION EVENT EVALUATION AND CLASSIFICATION).
oPersonnel shouldbeavailable forsamplingduringthisprocedure.
o Adverse CNMT values should be used whenever CNMT pressure is , greater than 4 psig or CNMT radiation is greater than 10+R/hr.*1 Monitor RCP Trip Criteria: a.RCP status-ANY RCP RUNNING b.SI pumps-AT LEAST TWO RUNNING c.RCS pressure minus maximum S/G pressure--LESS THAN 175 psig (400 psig adverse CNMTj d.Stop both RCPs a.Go to Step 2.b.Go to Step 2.c.Go to Step 2.  
oConditions shouldbeevaluated forSiteContingency Reporting (EPIP-1.0, GINNASTATIONEVENTEVALUATION ANDCLASSIFICATION).
oAdverseCNMTvaluesshouldbeusedwheneverCNMTpressureis,greaterthan4psigorCNMTradiation isgreaterthan10+R/hr.*1MonitorRCPTripCriteria:
a.RCPstatus-ANYRCPRUNNINGb.SIpumps-ATLEASTTWORUNNINGc.RCSpressureminusmaximumS/Gpressure--LESSTHAN175psig(400psigadverseCNMTjd.StopbothRCPsa.GotoStep2.b.GotoStep2.c.GotoStep2.  
\
\
EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE4of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED2IdentifyRupturedS/G(s):oUnexpected increaseineitherS/Gnarrowrangelevel-OR-ContinuewithSteps6through11.WHENrupturedS/G(s)identified, THENdoSteps3,4and5.oHighradiation indication onmainsteamline radiation monitor~R-31forS/GA~R-32forS/GB-OR-oAOreportslocalindication ofhighsteamline radiation
EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 4 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 2 Identify Ruptured S/G(s): o Unexpected increase in either S/G narrow range level-OR-Continue with Steps 6 through 11.WHEN ruptured S/G(s)identified, THEN do Steps 3, 4 and 5.o High radiation indication on main steamline radiation monitor~R-31 for S/G A~R-32 for S/G B-OR-o AO reports local indication of high steamline radiation-OR-o RP reports high radiation from S/G activity sample 4 WJ EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 5 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED************
-OR-oRPreportshighradiation fromS/Gactivitysample 4WJ EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE5of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED************
x****x*%*********************
x****x*%*********************
CAUTIONoIFTHETDAFWPUMP.ISTHEONLYAVAILABLE SOURCEOFFEEDFLOW,STEAMSUPPLYTOTHETDAFWPUMPMUSTBEMAINTAINED FROMONES/G.oATLEASTONES/GSHALLBEMAINTAINED AVAILABLE FORRCSCOOLDOWN.
CAUTION o IF THE TDAFW PUMP.IS THE ONLY AVAILABLE SOURCE OF FEED FLOW, STEAM SUPPLY TO THE TDAFW PUMP MUST BE MAINTAINED FROM ONE S/G.o AT LEAST ONE S/G SHALL BE MAINTAINED AVAILABLE FOR RCS COOLDOWN.3 Isolate Flow From Ruptured S/G (s): a.Adjust ruptured S/G ARV controller to'050 psig in AUTO b.Check ruptured S/G ARV-CLOSED b.WHEN ruptured S/G pressure less than 1050 psig, THEN verify S/G ARV closed.IF NOT closed, THEN place controller in MANUAL and close S/G ARV.IF S/G ARV can NOT be closed, THEN dispatch AO to*locally isolate.c.Close ruptured S/G TDAFW pump steam supply valve and place in PULL STOP~S/G A, MOV-3505A~S/G B, MOV-3504A c.IF at least one MDAFW pump running, THEN dispatch AO with locked valve key to locally isolate steam from ruptured S/G to TDAFW pump.~S/G A, V-3505~S/G B, V-3504 d.Verify ruptured S/G blowdown valve-CLOSED d.Place S/G blowdown and sample valve isolation switch to CLOSE.~S/G A, AOV-5738~S/G B, AOV-5737 IF blowdown can NOT be isolated manually, THEN dispatch AO to locally isolate blowdown..
3IsolateFlowFromRupturedS/G(s):a.AdjustrupturedS/GARVcontroller to'050psiginAUTOb.CheckrupturedS/GARV-CLOSEDb.WHENrupturedS/Gpressurelessthan1050psig,THENverifyS/GARVclosed.IFNOTclosed,THENplacecontroller inMANUALandcloseS/GARV.IFS/GARVcanNOTbeclosed,THENdispatchAOto*locallyisolate.c.CloserupturedS/GTDAFWpumpsteamsupplyvalveandplaceinPULLSTOP~S/GA,MOV-3505A
~S/G A, V-5701~S/G B, V-5702 a1 Ill I't il U EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 6 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Complete Ruptured S/G Isolation:
~S/GB,MOV-3504A c.IFatleastoneMDAFWpumprunning,THENdispatchAOwithlockedvalvekeytolocallyisolatesteamfromrupturedS/GtoTDAFWpump.~S/GA,V-3505~S/GB,V-3504d.VerifyrupturedS/Gblowdownvalve-CLOSEDd.PlaceS/Gblowdownandsamplevalveisolation switchtoCLOSE.~S/GA,AOV-5738~S/GB,AOV-5737IFblowdowncanNOTbeisolatedmanually, THENdispatchAOtolocallyisolateblowdown..
a.Close ruptured S/G MSIV-RUPTURED S/G MSIV CLOSED a.Perform the following:
~S/GA,V-5701~S/GB,V-5702 a1IllI'tilU EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE6of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED4CompleteRupturedS/GIsolation:
1)Close intact S/G MSIV.2)Place intact S/G ARV controller at 1005 psig in AUTO.3)Place condenser steam dump mode selector switch to MANUAL.4)Adjust condenser steam dump controller to 1050 psig in AUTO.5)Adjust reheat steam supply controller cam to close reheat steam supply valves.6)Ensure turbine stop valves CLOSED.7)Dispatch AO to complete ruptured S/G isolation (Refer to Attachment RUPTURED S/G, parts A and B).b.Dispatch AO to complete ruptured S/G isolation (Refer to Attachment RUPTURED S/G part A)IF the ruptured S/G can NOT be isolated from the intact S/G, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT SUBCOOLED RECOVERY DESIRED, Step 1 L~Qt J>;
a.CloserupturedS/GMSIV-RUPTUREDS/GMSIVCLOSEDa.Performthefollowing:
EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 7 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**********
1)CloseintactS/GMSIV.2)PlaceintactS/GARVcontroller at1005psiginAUTO.3)Placecondenser steamdumpmodeselectorswitchtoMANUAL.4)Adjustcondenser steamdumpcontroller to1050psiginAUTO.5)Adjustreheatsteamsupplycontroller camtoclosereheatsteamsupplyvalves.6)EnsureturbinestopvalvesCLOSED.7)DispatchAOtocompleterupturedS/Gisolation (RefertoAttachment RUPTUREDS/G,partsAandB).b.DispatchAOtocompleterupturedS/Gisolation (RefertoAttachment RUPTUREDS/GpartA)IFtherupturedS/GcanNOTbeisolatedfromtheintactS/G,THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANTSUBCOOLED RECOVERYDESIRED,Step1 L~QtJ>;
x*a***x x x x%*x x*****************
EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE7of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED**********
CAUTION IF ANY RUPTURED S/G IS FAULTED, FEED FLOW TO THAT S/G SHOULD REMAIN ISOLATED DURING SUBSEQUENT RECOVERY ACTIONS UNLESS NEEDED FOR RCS COOLDOWN.5 Check Ruptured S/G Level: a.Narrow range level-GREATER THAN 5%[25%adverse CNMT)a.IF ruptured S/G NOT faulted, THEN perform the following:
x*a***xxxx%*xx*****************
l)Maintain feed flow to ruptured S/G until level greater than 5%[25%adverse CNMT).2)Continue with Step 6.WHEN ruptured S/G level greater than 5%[25%adverse CNMT], THEN do Steps 5b through e.b.Close MDAFW pump discharge valv'e to ruptured S/G b.Dispatch AO to locally close valve.~S/G A, MOV-4007~S/G B, MOV-4008 c.Pull stop MDAFW pump for ruptured S/G d.Close TDAFW pump flow control valve to ruptured S/G~S/G A, AOV-4297~S/G B, AOV-4298 e.Verify MDAFW pump crosstie valves-CLOSED d.Dispatch AO with locked valve key to locally close TDAFW pump manual feedwater isolation valve to ruptured S/G.~S/G A, V-4005~S/G B, V-4006 e.Manually close valves.~MOV-4000A~MOV-4000B U~W~p*~ga t, r.g'1 EOP: E-3 ijiLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 8 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**********
CAUTIONIFANYRUPTUREDS/GISFAULTED,FEEDFLOWTOTHATS/GSHOULDREMAINISOLATEDDURINGSUBSEQUENT RECOVERYACTIONSUNLESSNEEDEDFORRCSCOOLDOWN.
5CheckRupturedS/GLevel:a.Narrowrangelevel-GREATERTHAN5%[25%adverseCNMT)a.IFrupturedS/GNOTfaulted,THENperformthefollowing:
l)MaintainfeedflowtorupturedS/Guntillevelgreaterthan5%[25%adverseCNMT).2)ContinuewithStep6.WHENrupturedS/Glevelgreaterthan5%[25%adverseCNMT],THENdoSteps5bthroughe.b.CloseMDAFWpumpdischarge valv'etorupturedS/Gb.DispatchAOtolocallyclosevalve.~S/GA,MOV-4007~S/GB,MOV-4008c.PullstopMDAFWpumpforrupturedS/Gd.CloseTDAFWpumpflowcontrolvalvetorupturedS/G~S/GA,AOV-4297~S/GB,AOV-4298e.VerifyMDAFWpumpcrosstievalves-CLOSEDd.DispatchAOwithlockedvalvekeytolocallycloseTDAFWpumpmanualfeedwater isolation valvetorupturedS/G.~S/GA,V-4005~S/GB,V-4006e.Manuallyclosevalves.~MOV-4000A
~MOV-4000B U~W~p*~gat,r.g'1 EOP:E-3ijiLE:STEAMGENERATOR TUBERUPTUREREV15PAGE8of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED**********
x*****x**%*********************
x*****x**%*********************
CAUTIONIFANYPRZRPORVOPENSBECAUSEOFHIGHPRZRPRESSURE, ITSHOULDBECLOSEDAFTERPRESSUREDECREASES TOLESSTHAN2335PSIG(REFERTOSTEP6B).**************
CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 6B).**************
P***x0x*0***x**************
P***x 0 x*0***x**************
*6MonitorPRZRPORVsAndBlockValves:a.PowertoPORVblockvalvesAVAILABLE a.RestorepowertoblockvalvesunlessblockvalvewasclosedtoisolateanopenPORV:b.PORVs-CLOSED~MOV-515,MCCCposition6C~MOV-516,MCCDposition6Cb.IFPRZRpressurelessthan2335psig,THENmanuallyclosePORVs.c.Blockvalves-ATLEASTONEOPENIFanyPORVcanNOTbeclosed,THENmanuallycloseitsblockvalve.IFblockvalvecanNOTbeclosed,THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1.c.OpenoneblockvalveunlessitwasclosedtoisolateanopenPORV.
*6 Monitor PRZR PORVs And Block Valves: a.Power to PORV block valves AVAILABLE a.Restore power to block valves unless block valve was closed to isolate an open PORV: b.PORVs-CLOSED~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C b.IF PRZR pressure less than 2335 psig, THEN manually close PORVs.c.Block valves-AT LEAST ONE OPEN IF any PORV can NOT be closed, THEN manually close its block valve.IF block valve can NOT be closed, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.c.Open one block valve unless it was closed to isolate an open PORV.
P'>fg EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE9of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED7CheckIfS/GSecondary SideIsIntact:oPressureinbothS/Gs-STABLEORINCREASING IFanyS/Gpressuredecreasing inanuncontrolled mannerORcompletely depressurized, THENverifyfaultedS/GisolatedunlessneededforRCScooldown:
P'>fg EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 9 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Check If S/G Secondary Side Is Intact: o Pressure in both S/Gs-STABLE OR INCREASING IF any S/G pressure decreasing in an uncontrolled manner OR completely depressurized, THEN verify faulted S/G isolated unless needed for RCS cooldown: o Pressure in both S/Gs-GREATER THAN 100 PSIG~Steamlines
oPressureinbothS/Gs-GREATERTHAN100PSIG~Steamlines
~Feedlines IF faulted S/G NOT isolated, THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step 1.**********
~Feedlines IFfaultedS/GNOTisolated, THENgotoE-2,FAULTEDSTEAMGENERATOR ISOLATION, Step1.**********
x%**x%x x x x**x******************
x%**x%xxxx**x******************
CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).*******x*4*%x*x**x**%********************
CAUTIONIFCSTLEVELDECREASES TOLESSTHAN5FEET,THENALTERNATE WATERSOURCESFORAFWPUMPSWILLBENECESSARY (REFERTOER-AFW.1, ALTERNATE WATERSUPPLYTOAFWPUMPS).*******x*4*%x*x**x**%********************
NOTE: TDAFW pump flow control valves fail open on loss of IA.*8 Monitor Intact S/G Level: a.Narrow range level-GREATER THAN 5%[25%adverse CNMT)b.Control feed flow to maintain narrow range level between 17%[25%adverse CNMT)and 50%a.Maintain total feed flow greater than 200 gpm until narrow range level greater than 5%[25%adverse CNMT)in at least one S/G.b.IF narrow range level in, the intact S/G continues to increase in an uncontrolled manner, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l.  
NOTE:TDAFWpumpflowcontrolvalvesfailopenonlossofIA.*8MonitorIntactS/GLevel:a.Narrowrangelevel-GREATERTHAN5%[25%adverseCNMT)b.Controlfeedflowtomaintainnarrowrangelevelbetween17%[25%adverseCNMT)and50%a.Maintaintotalfeedflowgreaterthan200gpmuntilnarrowrangelevelgreaterthan5%[25%adverseCNMT)inatleastoneS/G.b.IFnarrowrangelevelin,theintactS/Gcontinues toincreaseinanuncontrolled manner,THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Stepl.  
%tk Cg gt EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 10 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED********x*x~*%x'.*x x*a*x x**x x***x*********CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN, SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
%tkCggt EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE10of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED********x*x~*%x'.*xx*a*xx**xx***x*********
CAUTIONIFOFFSITEPOWERISLOSTAFTERSIRESET,THEN,SELECTEDSWPUMPSANDONECCWPUMPWILLAUTOSTARTONEMERGENCY D/G.MANUALACTIONWILLBEREQUIREDTORESTARTSAFEGUARDS EQUIPMENT.
**********
**********
xxx**xx*x***x******************
x x x**x x*x***x******************
9ResetSI10ResetCI:a.DepressCIresetpushbutton b.Verifyannunciator A-26,CNMTISOLATION
9 Reset SI 10 Reset CI: a.Depress CI reset pushbutton b.Verify annunciator A-26, CNMT ISOLATION-EXTINGUISHED b.Perform the following:
-EXTINGUISHED b.Performthefollowing:
1)Reset SI.2)Depress CI reset pushbutton.
1)ResetSI.2)DepressCIresetpushbutton.
**************
**************
xx**xxx********************
x x**x x x********************
CAUTIONRCSPRESSURESHOULDBEMONITORED.
CAUTION RCS PRESSURE SHOULD BE MONITORED.
IFRCSPRESSUREDECREASES TOLESSTHAN250PSIG[465PSIGADVERSECNMT),THENTHERHRPUMPSMUSTBEMANUALLYRESTARTED TOSUPPLYWATERTOTHERCS.**********%
IF RCS PRESSURE DECREASES TO LESS THAN 250 PSIG[465 PSIG ADVERSE CNMT), THEN THE RHR PUMPS MUST BE MANUALLY RESTARTED TO SUPPLY WATER TO THE RCS.**********%
*****xx**x********************
*****x x**x********************
11CheckIfRHRPumpsShouldBeStopped:a.CheckRCSpressure:
11 Check If RHR Pumps Should Be Stopped: a.Check RCS pressure: a.Go to Step 12.o Pressure-GREATER THAN 250 psig[465 psig adverse CNMTj o Pressure-STABLE OR INCREASING b.Stop RHR pumps and place both in AUTO fA~m f+J g~'k EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 11 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: If ruptured S/G needed for cooldown, isolation is not necessary.
a.GotoStep12.oPressure-GREATERTHAN250psig[465psigadverseCNMTjoPressure-STABLEORINCREASING b.StopRHRpumpsandplacebothinAUTO fA~mf+Jg~'k EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE11of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDNOTE:IfrupturedS/Gneededforcooldown, isolation isnotnecessary.
12 Verify Ruptured S/G Isolated: a.Check ruptured MSIV-CLOSED b.Ruptured S/G pressure-GREATER THAN 300 PSIG a.IF only intact S/G MSIV can be closed, THEN ensure air ejector/gland steam supply and flange heating steam isolated.(Refer to ATTACHMENT RUPTURED S/G, part B).IF neither S/G MSIV can be closed THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT SUBCOOLED RECOVERY DESIRED, Step 1 b.Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.13 Establish Condenser Steam Dump Pressure Control: a.Verify condenser available:
12VerifyRupturedS/GIsolated:
o Intact S/G MSIV-OPEN o Annunciator G-15, STEAM DUMP ARMED-LIT a.Adjust S/G ARV controllers to maintain intact S/G pressure in AUTO and go to Step 14.b.Adjust condenser steam dump controller HC-484 to maintain intact S/G pressure and verify in AUTO c.Place steam dump mode selector switch to MANUAL
a.CheckrupturedMSIV-CLOSEDb.RupturedS/Gpressure-GREATERTHAN300PSIGa.IFonlyintactS/GMSIVcanbeclosed,THENensureairejector/gland steamsupplyandflangeheatingsteamisolated.
~s'I~l I c~i~g V W EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 12 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Following initiation of controlled cooldown or depressurization, RCP trip criteria is no longer applicable.
(RefertoATTACHMENT RUPTUREDS/G,partB).IFneitherS/GMSIVcanbeclosedTHENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANTSUBCOOLED RECOVERYDESIRED,Step1b.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1.13Establish Condenser SteamDumpPressureControl:a.Verifycondenser available:
14 Initiate RCS Cooldown: a.Determine required core exit temperature from below table RUPTURED SG PRESSURE 1100 PSIG 1000 PSIG 900 PSIG 800 PSIG 700 PSIG 600 PSIG 500 PSIG 400 PSIG 300 PSIG REQUIRED CORE EXIT TEMPERATURE
oIntactS/GMSIV-OPENoAnnunciator G-15,STEAMDUMPARMED-LITa.AdjustS/GARVcontrollers tomaintainintactS/GpressureinAUTOandgotoStep14.b.Adjustcondenser steamdumpcontroller HC-484tomaintainintactS/GpressureandverifyinAUTOc.PlacesteamdumpmodeselectorswitchtoMANUAL
('F)525[505 adverse CNMT)510[490 adverse CNMT)500[475 adverse CNMT]485[460 adverse CNMT)465[440 adverse CNMT)450[420 adverse CNMT)425[395 adverse CNMT]405[370 adverse CNMT)375[330 adverse CNMT)b.Initiate dumping steam to condenser from intact S/G at maximum rate b.Manually or locally initiate steam dump from intact S/G at maximum rate using S/G ARV.IF no intact S/G available, THEN perform the following:
~s'I~lIc~i~gVW EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE12of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDNOTE:Following initiation ofcontrolled cooldownordepressurization, RCPtripcriteriaisnolongerapplicable.
o Use faulted S/G.-OR-c.Core exit T/Cs-LESS THAN REQUIRED TEMPERATURE d.Stop RCS cooldown and maintain core exit T/Cs less than required temperature o IF both S/Gs ruptured, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT SUBCOOLED RECOVERY DESIRED, Step 1 c.Continue with Step 15.WHEN core exit T/Cs less than required, THEN do Step 14d.  
14InitiateRCSCooldown:
+k~f EOP: E-3 TtTLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 13 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*15 Monitor All AC Busses-BUSSES ENERGIZED BY OFFSITE POWER o Normal feed breakers to all 480 volt busses-CLOSED o 480 volt bus voltage-GREATER THAN 420 VOLTS o Emergency D/G output breakers OPEN Perform the following:
a.Determine requiredcoreexittemperature frombelowtableRUPTUREDSGPRESSURE1100PSIG1000PSIG900PSIG800PSIG700PSIG600PSIG500PSIG400PSIG300PSIGREQUIREDCOREEXITTEMPERATURE
a.IF any AC emergency bus normal feed breaker open, THEN ensure associated D/G breaker closed.b.Perform the following as necessary:
('F)525[505adverseCNMT)510[490adverseCNMT)500[475adverseCNMT]485[460adverseCNMT)465[440adverseCNMT)450[420adverseCNMT)425[395adverseCNMT]405[370adverseCNMT)375[330adverseCNMT)b.Initiatedumpingsteamtocondenser fromintactS/Gatmaximumrateb.ManuallyorlocallyinitiatesteamdumpfromintactS/GatmaximumrateusingS/GARV.IFnointactS/Gavailable, THENperformthefollowing:
1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Place the following pumps in PULL STOP:~EH pumps~Turning gear oil pump~HP seal oil backup pump 3)Restore power to MCCs.~A from Bus 13~B from Bus 15~E from Bus 15~F from Bus 15 4)Start CNMT RECIRC fans as necessary.
oUsefaultedS/G.-OR-c.CoreexitT/Cs-LESSTHANREQUIREDTEMPERATURE d.StopRCScooldownandmaintaincoreexitT/Cslessthanrequiredtemperature oIFbothS/Gsruptured, THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANTSUBCOOLED RECOVERYDESIRED,Step1c.ContinuewithStep15.WHENcoreexitT/Cslessthanrequired, THENdoStep14d.  
5)WHEN bus 15 restored, THEN reset control room lighting.c.Try to restore offsite power to all AC busses (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).
+k~f EOP:E-3TtTLE:STEAMGENERATOR TUBERUPTUREREV15PAGE13of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*15MonitorAllACBusses-BUSSESENERGIZED BYOFFSITEPOWERoNormalfeedbreakerstoall480voltbusses-CLOSEDo480voltbusvoltage-GREATERTHAN420VOLTSoEmergency D/GoutputbreakersOPENPerformthefollowing:
pffft'Ill p%~I 4, r l~
a.IFanyACemergency busnormalfeedbreakeropen,THENensureassociated D/Gbreakerclosed.b.Performthefollowing asnecessary:
EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV'5 PAGE 14 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 16 Verify Adequate SW Flow: a.Check at least two SW pumps RUNNING a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN: 1)Ensure SW isolation.
1)Closenon-safeguards bustiebreakers:
2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)3)Go to Step 18.  
~Bus13toBus14tie~Bus15toBus16tie2)Placethefollowing pumpsinPULLSTOP:~EHpumps~Turninggearoilpump~HPsealoilbackuppump3)RestorepowertoMCCs.~AfromBus13~BfromBus15~EfromBus15~FfromBus154)StartCNMTRECIRCfansasnecessary.
<<I EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 15 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Establish IA to CNMT: a.Verify non-safeguards busses energized o Bus 13 normal feed-CLOSED a.Perform the following:
5)WHENbus15restored, THENresetcontrolroomlighting.
1)Close non-safeguards bus tie breakers:-OR-o Bus 15 normal feed-CLOSED~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Verify adequate emergency D/G capacity to run air compressors (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans should be stopped (Refer to Attachment CNMT RECIRC FANS).b.Verify turbine building SW isolation valves-OPEN b.Manually align valves.~MOV-4613 and MOV-4670~MOV-4614 and MOV-4664 c.Verify at least two air compressors
c.TrytorestoreoffsitepowertoallACbusses(RefertoER-ELEC.1, RESTORATION OFOFFSITEPOWER).
-RUNNING d.Check IA supply: c.Manually start air compressors as power supply permits (75 kw each).IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.
pffft'Ill p%~I4,rl~
d.Perform the following:
EOP:E-3STEAMGENERATOR TUBERUPTUREREV'5PAGE14of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED16VerifyAdequateSWFlow:a.CheckatleasttwoSWpumpsRUNNINGa.ManuallystartSWpumpsaspowersupplypermits(258kweach).IFlessthantwoSWpumpsrunning,THEN:1)EnsureSWisolation.
o Pressure-GREATER THAN 60 PSIG o Pressure-STABLE OR INCREASING 1)Continue attempts to restore IA (Refer to AP-IA.1, LOSS OF INSTRUMENT AIR).2)Continue with Step 18.WHEN IA restored, THEN do Steps 17e and f.e.Reset both trains of XY relays for IA to CNMT AOV-5392 f.Verify IA to CNMT AOV-5392-OPEN I'4*4-'p'il I%P bl QI Cal EOP: LITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 16 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Establish Charging Flow: a.Charging pumps-ANY RUNNING a.Perform the following:
2)DispatchAOtoestablish normalshutdownalignment (RefertoAttachment SD-1)b.DispatchAOtoestablish normalshutdownalignment (RefertoAttachment SD-1)3)GotoStep18.  
1)IF CCW flow is lost to any RCP thermal barrier OR any RCP&#xb9;1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to locally close seal injection needle valves to affected RCP.~V-300A for RCP A~V-300B for RCP B b.Align charging pump suction to RWST: 2)Ensure HCV-142 demand at 0%.b.IF LCV-112B can NOT be opened, THEN perform the following:
<<I EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE15of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED17Establish IAtoCNMT:a.Verifynon-safeguards bussesenergized oBus13normalfeed-CLOSEDa.Performthefollowing:
o LCV-112B-OPEN o LCV-112C-CLOSED 1)Verify charging pump A NOT running and place in PULL STOP.c.Start charging pumps as necessary and establish 75 gpm total charging flow 2)Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).3)WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).~Charging line flow~Seal inj ection
1)Closenon-safeguards bustiebreakers:
)%%41 e' EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 17 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED************x*x**x**x*%
-OR-oBus15normalfeed-CLOSED~Bus13toBus14tie~Bus15toBus16tie2)Verifyadequateemergency D/Gcapacitytorunaircompressors (75kweach).IFNOT,THENevaluateifCNMTRECIRCfansshouldbestopped(RefertoAttachment CNMTRECIRCFANS).b.VerifyturbinebuildingSWisolation valves-OPENb.Manuallyalignvalves.~MOV-4613andMOV-4670~MOV-4614andMOV-4664c.Verifyatleasttwoaircompressors
-RUNNINGd.CheckIAsupply:c.Manuallystartaircompressors aspowersupplypermits(75kweach).IFaircompressors canNOTbestarted,THENdispatchAOtolocallyresetcompressors asnecessary.
d.Performthefollowing:
oPressure-GREATERTHAN60PSIGoPressure-STABLEORINCREASING 1)ContinueattemptstorestoreIA(RefertoAP-IA.1,LOSSOFINSTRUMENT AIR).2)ContinuewithStep18.WHENIArestored, THENdoSteps17eandf.e.ResetbothtrainsofXYrelaysforIAtoCNMTAOV-5392f.VerifyIAtoCNMTAOV-5392-OPEN I'4*4-'p'ilI%PblQICal EOP:LITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE16of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED18Establish ChargingFlow:a.Chargingpumps-ANYRUNNINGa.Performthefollowing:
1)IFCCWflowislosttoanyRCPthermalbarrierORanyRCP&#xb9;1sealoutlettemperature offscalehigh,THENdispatchAOwithkeytoRWSTgatetolocallyclosesealinjection needlevalvestoaffectedRCP.~V-300AforRCPA~V-300BforRCPBb.AlignchargingpumpsuctiontoRWST:2)EnsureHCV-142demandat0%.b.IFLCV-112BcanNOTbeopened,THENperformthefollowing:
oLCV-112B-OPENoLCV-112C-CLOSED1)VerifychargingpumpANOTrunningandplaceinPULLSTOP.c.Startchargingpumpsasnecessary andestablish 75gpmtotalchargingflow2)DispatchAOtolocallyopenmanualchargingpumpsuctionfromRWST(V-358locatedinchargingpumproom).3)WHENV-358open,THENdirectAOtocloseV-268toisolatechargingpumpsBandCfromVCT(V-268locatedinchargingpumproom).~Charginglineflow~Sealinjection
)%%41e' EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE17of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED************x*x**x**x*%
******x***********
******x***********
CAUTIONRCSCOOLDOWNINSTEP14SHOULDBECOMPLETED BEFORECONTINUING TOSTEP19.**********x****x xxx**xxx**x**x***********
CAUTION RCS COOLDOWN IN STEP 14 SHOULD BE COMPLETED BEFORE CONTINUING TO STEP 19.**********x****x x x x**x x x**x**x***********
19CheckRupturedS/GPressure-STABLEORINCREASING IFpressurecontinues todecreasetolessthan250psiabovethepressureoftheintactS/G,THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Stepl.20CheckRCSSubcooling BasedOnCoreExitT/Cs-GREATERTHAN20'FUSINGFIGUREMINSUBCOOLING GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1
19 Check Ruptured S/G Pressure-STABLE OR INCREASING IF pressure continues to decrease to less than 250 psi above the pressure of the intact S/G, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l.20 Check RCS Subcooling Based On Core Exit T/Cs-GREATER THAN 20'F USING FIGURE MIN SUBCOOLING Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1
'k EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE18of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDNOTE:SIACCUMsmayinjectduringRCSdepressurization.
'k EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 18 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: SI ACCUMs may inject during RCS depressurization.
21Depressurize RCSToMinimizeBreakFlowAndRefillPRZR:a.Checkthefollowing:
21 Depressurize RCS To Minimize Break Flow And Refill PRZR: a.Check the following:
oRupturedS/Glevel-LESSTHAN90%[85%adverseCNMTjoAnyRCP-RUNNINGoIAtoCNMT-AVAILABLE b.SprayPRZRwithmaximumavailable sprayuntilANYofthefollowing conditions satisfied:
o Ruptured S/G level-LESS THAN 90%[85%adverse CNMTj o Any RCP-RUNNING o IA to CNMT-AVAILABLE b.Spray PRZR with maximum available spray until ANY of the following conditions satisfied:
oPRZRlevel-GREATERTHAN75%[65%adverseCNMT)-OR-oRCSpressure-LESSTHANSATURATION USINGFIGUREMINSUBCOOLING
o PRZR level-GREATER THAN 75%[65%adverse CNMT)-OR-o RCS pressure-LESS THAN SATURATION USING FIGURE MIN SUBCOOLING-OR-o BOTH of the following:
-OR-oBOTHofthefollowing:
1)RCS pressure-LESS THAN RUPTURED S/G PRESSURE 2)PRZR level-GREATER THAN 5%[30%adverse CNMT]c.Close normal PRZR spray valves: 1)Adjust normal spray valve controller to 0%DEMAND 2)Verify RCS pressure INCREASING d.Verify auxiliary spray valve (AOV-296)-CLOSED e.Go to Step 24 a.Go to Step 22.c.Stop RCPs.d.Decrease charging speed to minimum and ensure charging valve to loop B cold leg open (AOV-294).
1)RCSpressure-LESSTHANRUPTUREDS/GPRESSURE2)PRZRlevel-GREATERTHAN5%[30%adverseCNMT]c.ClosenormalPRZRsprayvalves:1)Adjustnormalsprayvalvecontroller to0%DEMAND2)VerifyRCSpressureINCREASING d.Verifyauxiliary sprayvalve(AOV-296)
re%4',r, f' EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 19 of'38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED***********
-CLOSEDe.GotoStep24a.GotoStep22.c.StopRCPs.d.DecreasechargingspeedtominimumandensurechargingvalvetoloopBcoldlegopen(AOV-294).
4**x~x x x x x x*x**x**************
re%4',r,f' EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE19of'38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED***********
CAUTION o THE PRT MAY RUPTURE IF A PRZR PORV IS USED TO DEPRESSURIZE THE RCS.THIS MAY RESULT IN ABNORMAL CNMT CONDITIONS.
4**x~xxxxxx*x**x**************
o CYCLING OF THE PRZR PORV SHOULD BE MINIMIZED.
CAUTIONoTHEPRTMAYRUPTUREIFAPRZRPORVISUSEDTODEPRESSURIZE THERCS.THISMAYRESULTINABNORMALCNMTCONDITIONS.
o THE UPPER HEAD REGION MAY VOID DURING RCS DEPRESSURIZATION IF RCPS ARE NOT RUNNING.THIS MAY RESULT IN A RAPIDLY INCREASING PRZR LEVEL.*******x%**x***4 x*x x 4********************
oCYCLINGOFTHEPRZRPORVSHOULDBEMINIMIZED.
NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.o When using a PRZR PORV select one with an operable block valve.22 Depressurize RCS Using PRZR PORV To Minimize Break Flow And Refill PRZR: a.Verify IA to CNMT-AVAILABLE b.PRZR PORVs-AT LEAST ONE AVAILABLE a.Refer to Attachment N2 PORVS to operate PORVs.b.IF auxiliary spray available, THEN return to Step 21b.IF auxiliary spray can NOT be established, THEN go to ECA-3.3, SGTR WITHOUT PRESSURIZER PRESSURE CONTROL, Step 1.This Step continued on the next page.  
oTHEUPPERHEADREGIONMAYVOIDDURINGRCSDEPRESSURIZATION IFRCPSARENOTRUNNING.THISMAYRESULTINARAPIDLYINCREASING PRZRLEVEL.*******x%**x***4x*xx4********************
~A 4 EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 20 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED (Step 22 continued from previous page)c.Open one PRZR PORV until ANY of the following conditions satisfied:
NOTE:oIfauxiliary sprayisinuse,sprayflowmaybeincreased byclosingnormalchargingvalveAOV-294andnormalPRZRsprayvalves.oWhenusingaPRZRPORVselectonewithanoperableblockvalve.22Depressurize RCSUsingPRZRPORVToMinimizeBreakFlowAndRefillPRZR:a.VerifyIAtoCNMT-AVAILABLE b.PRZRPORVs-ATLEASTONEAVAILABLE a.RefertoAttachment N2PORVStooperatePORVs.b.IFauxiliary sprayavailable, THENreturntoStep21b.IFauxiliary spraycanNOTbeestablished, THENgotoECA-3.3,SGTRWITHOUTPRESSURIZER PRESSURECONTROL,Step1.ThisStepcontinued onthenextpage.  
o PRZR level-GREATER THAN 75%(65%adverse CNMT]-OR-o RCS pressure-LESS THAN SATURATION USING FIGURE MIN SUBCOOLING-OR'-o BOTH of the following:
~A4 EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE20of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED(Step22continued frompreviouspage)c.OpenonePRZRPORVuntilANYofthefollowing conditions satisfied:
1)RCS pressure-LESS THAN RUPTURED S/G PRESSURE 2)PRZR level-GREATER THAN 5%(30%adverse CNMT]d.Close PRZR PORVs d.IF either PRZR PORV can NOT be closed, THEN close associated block valve.
oPRZRlevel-GREATERTHAN75%(65%adverseCNMT]-OR-oRCSpressure-LESSTHANSATURATION USINGFIGUREMINSUBCOOLING
J g~~'
-OR'-oBOTHofthefollowing:
EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 21 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 23 Check RCS Pressure-INCREASING Close block valve for the PRZR PORV that was opened.IF pressure continues to decrease, THEN perform the following:
1)RCSpressure-LESSTHANRUPTUREDS/GPRESSURE2)PRZRlevel-GREATERTHAN5%(30%adverseCNMT]d.ClosePRZRPORVsd.IFeitherPRZRPORVcanNOTbeclosed,THENcloseassociated blockvalve.
a.Monitor the following conditions for indication of leakage from PRZR PORV: o PORV outlet temp (TI-438)NOT decreasing.
Jg~~'
o PRT pressure, level or temperature continue to increase.b.Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.
EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE21of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED23CheckRCSPressure-INCREASING CloseblockvalveforthePRZRPORVthatwasopened.IFpressurecontinues todecrease, THENperformthefollowing:
Cl 1 J C ,C EOP: E-3 T I l'LE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 22 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**************
a.Monitorthefollowing conditions forindication ofleakagefromPRZRPORV:oPORVoutlettemp(TI-438)NOTdecreasing.
0*x x w***x%*****************
oPRTpressure, levelortemperature continuetoincrease.
CAUTION SI MUST BE TERMINATED WHEN TERMINATION CRITERIA ARE SATISFIED TO PREVENT'OVERFILLING OF THE RUPTURED S/G.***********
b.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1.
x*x x**x 0*x**x%**x x*x******x***
Cl1JC,C EOP:E-3TIl'LE:STEAMGENERATOR TUBERUPTUREREV15PAGE22of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED**************
24 Check If SI Flow Should Be Terminated:
0*xxw***x%*****************
a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING b.Secondary heat sink: o Total feed flow to S/G(s)GREATER THAN 200 GPM AVAILABLE-OR-a.Do NOT stop SI pumps.Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.b.IF neither condition satisfied, THEN do NOT stop SI pumps.Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.o Narrow range level in at least one intact S/G GREATER THAN 5%[25%adverse CNMT)c.RCS pressure-STABLE OR INCREASING d.PRZR level-GREATER THAN 5%[30%adverse CNMT)c.Do NOT stop SI pumps.Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l.d.Do NOT stop SI pumps.Return to Step 12.
CAUTIONSIMUSTBETERMINATED WHENTERMINATION CRITERIAARESATISFIED TOPREVENT'OVERFILLING OFTHERUPTUREDS/G.***********
I'I EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 23 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 25 Stop SI Pumps And Place In AUTO 26 Establish Required Charging Line Flow: a.Charging pumps-ANY RUNNING b.Establish 20 gpm charging line flow a.Perform the following:
x*xx**x0*x**x%**xx*x******x***
1)IF CCW flow is lost to any RCP thermal barrier OR"any RCP 41 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to locally isolate seal injection to affected RCP:~RCP A, V-300A~RCP B, V-300B 2)Ensure HCV-142 open.3)Start one charging pump.*27 Monitor SI Reinitiation Criteria: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING b.PRZR level-GREATER THAN 5%[30%adverse CNMTj a.Manually operate SI pumps as necessary and go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l..b.Manually,.operate SI pumps as necessary.
24CheckIfSIFlowShouldBeTerminated:
IF PRZR level can NOT be maintained, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l.
a.RCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING b.Secondary heatsink:oTotalfeedflowtoS/G(s)GREATERTHAN200GPMAVAILABLE
yg'-u'I~fE'tI l ht EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 24 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*28 Monitor If CNMT Spray Should Be Stopped: a.CNMT spray pumps-ANY RUNNING b.Verify CNMT pressure-LESS THAN 4 PSIG c.Reset CNMT spray d.Check NaOH tank outlet valves CLOSED~AOV-836A~AOV-836B a.Go to Step 29.b.Continue'with Step 29.WHEN CNMT pressure less than 4 psig, THEN do Steps 28c through f.d.Place NaOH tank outlet valve controllers to MANUAL and close valves.e.Stop CNMT spray pumps and place in AUTO f.Close CNMT spray pump discharge valves~MOV-860A~MOV-860B~MOV-860C~MOV-860D I&q.II EOP: E-3 LITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 25 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 29 Check If SI ACCUMs Should Be Isolated: a.Check the following:
-OR-a.DoNOTstopSIpumps.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1.b.IFneithercondition satisfied, THENdoNOTstopSIpumps.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1.oNarrowrangelevelinatleastoneintactS/GGREATERTHAN5%[25%adverseCNMT)c.RCSpressure-STABLEORINCREASING d.PRZRlevel-GREATERTHAN5%[30%adverseCNMT)c.DoNOTstopSIpumps.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Stepl.d.DoNOTstopSIpumps.ReturntoStep12.
o RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Manually operate SI pumps as necessary and go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l.o PRZR level-GREATER THAN 5%[30%adverse CNMTj b.Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves~MOV-841, MCC C position 12F~MOV-865, MCC D position 12C c.Close SI ACCUM discharge valves~MOV-841~MOV-865 c.Vent any unisolated ACCUMs: 1)Open vent valves for unisolated SI ACCUMs.~ACCUM A, AOV-834A~ACCUM B, AOV-834B d.Locally reopen breakers for MOV-841 and MOV-865 2)Open HCV-945.
I'I EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE23of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED25StopSIPumpsAndPlaceInAUTO26Establish RequiredChargingLineFlow:a.Chargingpumps-ANYRUNNINGb.Establish 20gpmcharginglineflowa.Performthefollowing:
f.+tk hPW>,1$y 4 4s jf-Qy'"9,, t 4'X;i EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 26 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 30 Verify Adequate SW Flow To CCW Hx: a.Verify at least three SW pumps RUNNING b.Verify AUX BLDG SW isolation valves-AT LEAST ONE SET OPEN~MOV-4615 and MOV-4734~MOV-4616 and MOV-4735 a.Manually start pumps as power supply permits (258 kw each).IF less than two SW pumps can be operated, THEN go to Step 37.b.Establish SW to AUX BLDG (Refer to Attachment AUX BLDG SW).c.Verify CNMT RECIRC fan annunciator C-2, HIGH TEMPERATURE ALARM-EXTINGUISHED c.Dispatch AO to locally throttle flow to CCW Hx to between 5000 gpm and 6000 gpm total flow.
1)IFCCWflowislosttoanyRCPthermalbarrierOR"anyRCP41sealoutlettemperature offscalehigh,THENdispatchAOwithkeytoRWSTgatetolocallyisolatesealinjection toaffectedRCP:~RCPA,V-300A~RCPB,V-300B2)EnsureHCV-142open.3)Startonechargingpump.*27MonitorSIReinitiation Criteria:
4 I P EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 27 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 31 Check If Normal CVCS Operation Can Be Established a.Verify IA restored: o IA to CNMT (AOV-5392)
a.RCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING b.PRZRlevel-GREATERTHAN5%[30%adverseCNMTja.ManuallyoperateSIpumpsasnecessary andgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Stepl..b.Manually,.operate SIpumpsasnecessary.
-OPEN o IA pressure-GREATER THAN 60 PSIG a.Continue with Step 37.WHEN IA restored, THEN do Steps 31 through 36.b.Verify instrument bus D ENERGIZED c.CCW pumps-ANY RUNNING b.Energize MCC B.IF MCC B NOT available, THEN perform the following:
IFPRZRlevelcanNOTbemaintained, THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Stepl.
1)Verify MCC A energized.
yg'-u'I~fE'tIlht EOP:E-3STEAMGENERATOR TUBERUPTUREREV15PAGE24of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*28MonitorIfCNMTSprayShouldBeStopped:a.CNMTspraypumps-ANYRUNNINGb.VerifyCNMTpressure-LESSTHAN4PSIGc.ResetCNMTsprayd.CheckNaOHtankoutletvalvesCLOSED~AOV-836A~AOV-836Ba.GotoStep29.b.Continue'with Step29.WHENCNMTpressurelessthan4psig,THENdoSteps28cthroughf.d.PlaceNaOHtankoutletvalvecontrollers toMANUALandclosevalves.e.StopCNMTspraypumpsandplaceinAUTOf.CloseCNMTspraypumpdischarge valves~MOV-860A~MOV-860B~MOV-860C~MOV-860D I&q.II EOP:E-3LITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE25of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED29CheckIfSIACCUMsShouldBeIsolated:
2)Place instrument bus D on maintenance supply.c.Perform the following:
a.Checkthefollowing:
1)IF any RCP tl seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected RCP(s).d.Charging pump-ANY RUNNING~RCP A, MOV-749A and MOV-759A~RCP B, MOV-749B and MOV-759B 2)Manually start one CCW pump.d.Continue with Step 37.WHEN any charging pump running, THEN do Steps 32 through 36.
oRCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING a.ManuallyoperateSIpumpsasnecessary andgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Stepl.oPRZRlevel-GREATERTHAN5%[30%adverseCNMTjb.DispatchAOwithlockedvalvekeytolocallyclosebreakersforSIACCUMdischarge valves~MOV-841,MCCCposition12F~MOV-865,MCCDposition12Cc.CloseSIACCUMdischarge valves~MOV-841~MOV-865c.Ventanyunisolated ACCUMs:1)Openventvalvesforunisolated SIACCUMs.~ACCUMA,AOV-834A~ACCUMB,AOV-834Bd.LocallyreopenbreakersforMOV-841andMOV-8652)OpenHCV-945.
I'1'r I V I IWg EOP: E-3 JIZLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 28 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 32 Check If Seal Return Flow Should Be Established:
f.+tkhPW>,1$y44sjf-Qy'"9,,t4'X;i EOP:E-3STEAMGENERATOR TUBERUPTUREREV15PAGE26of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED30VerifyAdequateSWFlowToCCWHx:a.VerifyatleastthreeSWpumpsRUNNINGb.VerifyAUXBLDGSWisolation valves-ATLEASTONESETOPEN~MOV-4615andMOV-4734~MOV-4616andMOV-4735a.Manuallystartpumpsaspowersupplypermits(258kweach).IFlessthantwoSWpumpscanbeoperated, THENgotoStep37.b.Establish SWtoAUXBLDG(RefertoAttachment AUXBLDGSW).c.VerifyCNMTRECIRCfanannunciator C-2,HIGHTEMPERATURE ALARM-EXTINGUISHED c.DispatchAOtolocallythrottleflowtoCCWHxtobetween5000gpmand6000gpmtotalflow.
a.Verify RCP&#xb9;1 seal outlet temperature
4IP EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE27of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED31CheckIfNormalCVCSOperation CanBeEstablished a.VerifyIArestored:
-LESS THAN 235'F b.Verify RCP seal outlet valves OPEN~AOV-270A~AOV-270B a.Go to Step 33.b.Manually open valves as necessary.
oIAtoCNMT(AOV-5392)
c.Reset both trains of XY relays for RCP seal return isolation valve MOV-313 d.Open RCP seal return isolation valve MOV-313 d.Perform the following:
-OPENoIApressure-GREATERTHAN60PSIGa.ContinuewithStep37.WHENIArestored, THENdoSteps31through36.b.Verifyinstrument busDENERGIZED c.CCWpumps-ANYRUNNINGb.EnergizeMCCB.IFMCCBNOTavailable, THENperformthefollowing:
1)Place MOV-313 switch to OPEN.e.Verify RCP&#xb9;1 seal leakoff flow LESS THAN 5.5 GPM 2)Dispatch AO with key to RWST gate to locally open MOV-313.e.IF any RCP seal leakoff flow greater than 5.5 gpm, THEN: o Close the affected RCP seal discharge valve~RCP A, AOV-270A~RCP B, AOV-270B f.Verify RCP&#xb9;1 seal leakoff flow GREATER THAN 0.25 GPM o Trip the affected RCP IF both RCP seal discharge valves are shut, THEN go to Step 33.f.Refer to AP-RCP.1, RCP SEAL MALFUNCTION.
1)VerifyMCCAenergized.
I.'~I~.4 Al tg~Ck EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 29 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 33 Verify PRZR Level-GREATER THAN 13%[40: adverse CNMT]Continue with Step 35.WHEN PRZR level increases to greater than 13%[40%adverse CNMT], THEN do Step 34.34 Establish Normal Letdown: a.Establish charging line flow to REGEN Hx-GREATER THAN 20 GPM b.Place the following switches to CLOSE:~Letdown orifice valves (AOV-200A, AOV-200B, and AOV-202)~Letdown isolation valve AOV-371~Loop B cold leg to REGEN Hx AOV-427 c.Place letdown controllers in MANUAL at 40%open~TCV-130~PCV-135 d.Reset both trains of XY relays for AOV-371 and AOV-427 e.Open AOV-371 and AOV-427 IF RCP seal return has been established, THEN establish excess letdown as follows: o Place excess letdown divert valve, AOV-312, to NORMAL.o Ensure CCW from excess letdown open, (AOV-745).
2)Placeinstrument busDonmaintenance supply.c.Performthefollowing:
o Open excess letdown isolation valve AOV-310.o Slowly open HCV-123 to maintain excess letdown temperature less than 195'F and pressure less than 100 psig.o Adjust charging pump speed as necessary.
1)IFanyRCPtlsealoutlettemperature offscalehigh,THENisolateCCWtothermalbarrierofaffectedRCP(s).d.Chargingpump-ANYRUNNING~RCPA,MOV-749AandMOV-759A~RCPB,MOV-749BandMOV-759B2)ManuallystartoneCCWpump.d.ContinuewithStep37.WHENanychargingpumprunning,THENdoSteps32through36.
IF RCP seal return NOT established, THEN consult TSC to determine if excess letdown should be placed in service.f.Open letdown orifice valves as necessary g.Place TCV-130 in AUTO at 105'F h.Place PCV-135 in AUTO at 250 psig i.Adjust charging pump speed and HCV-142 as necessary A h EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 30 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 35 Check VCT Makeup System: a.Adjust boric acid flow control valve in AUTO to 9.5 gpm b.Verify the following:
I'1'rIVIIWg EOP:E-3JIZLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE28of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED32CheckIfSealReturnFlowShouldBeEstablished:
1)RMW mode selector switch in AUTO b.Adjust controls as necessary.
a.VerifyRCP&#xb9;1sealoutlettemperature
2)RMW control armed-RED LIGHT LIT c.Check VCT level: o Level-GREATER THAN 20%-OR-o Level-STABLE OR INCREASING c.Manually increase VCT makeup flow as follows: 1)Ensure BA transfer pumps and RMW pumps running.IF NOT, THEN reset MCC C and MCC D UV~lockouts as necessary.
-LESSTHAN235'Fb.VerifyRCPsealoutletvalvesOPEN~AOV-270A~AOV-270Ba.GotoStep33.b.Manuallyopenvalvesasnecessary.
2)Place RMW flow control valve HCV-111 in MANUAL and increase RMW flow.3)Increase boric acid flow as necessary.
c.ResetbothtrainsofXYrelaysforRCPsealreturnisolation valveMOV-313d.OpenRCPsealreturnisolation valveMOV-313d.Performthefollowing:
I>~M t~, M.lt Cg~a~4~I P h~4 EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 31 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 36 Check Charging Pump Suction Aligned To VCT: a.VCT level-GREATER THAN 20%a.IF VCT level can NOT be maintained greater than 5%, THEN perform the following:
1)PlaceMOV-313switchtoOPEN.e.VerifyRCP&#xb9;1sealleakoffflowLESSTHAN5.5GPM2)DispatchAOwithkeytoRWSTgatetolocallyopenMOV-313.e.IFanyRCPsealleakoffflowgreaterthan5.5gpm,THEN:oClosetheaffectedRCPsealdischarge valve~RCPA,AOV-270A~RCPB,AOV-270Bf.VerifyRCP&#xb9;1sealleakoffflowGREATERTHAN0.25GPMoTriptheaffectedRCPIFbothRCPsealdischarge valvesareshut,THENgotoStep33.f.RefertoAP-RCP.1, RCPSEALMALFUNCTION.
1)Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed 2)Continue with Step 37.WHEN VCT level greater than 40%, THEN do Step 36b.b.Verify charging pumps aligned to VCT o LCV-112C-OPEN o LCV-112B-CLOSED b.Manually align valves as necessary.
I.'~I~.4Altg~Ck EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE29of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED33VerifyPRZRLevel-GREATERTHAN13%[40:adverseCNMT]ContinuewithStep35.WHENPRZRlevelincreases togreaterthan13%[40%adverseCNMT],THENdoStep34.34Establish NormalLetdown:a.Establish charginglineflowtoREGENHx-GREATERTHAN20GPMb.Placethefollowing switchestoCLOSE:~Letdownorificevalves(AOV-200A, AOV-200B, andAOV-202)~Letdownisolation valveAOV-371~LoopBcoldlegtoREGENHxAOV-427c.Placeletdowncontrollers inMANUALat40%open~TCV-130~PCV-135d.ResetbothtrainsofXYrelaysforAOV-371andAOV-427e.OpenAOV-371andAOV-427IFRCPsealreturnhasbeenestablished, THENestablish excessletdownasfollows:oPlaceexcessletdowndivertvalve,AOV-312,toNORMAL.oEnsureCCWfromexcessletdownopen,(AOV-745).
Pp<<4.ig%1EP EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 32 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**************
oOpenexcessletdownisolation valveAOV-310.oSlowlyopenHCV-123tomaintainexcessletdowntemperature lessthan195'Fandpressurelessthan100psig.oAdjustchargingpumpspeedasnecessary.
x**x*x x x*******************
IFRCPsealreturnNOTestablished, THENconsultTSCtodetermine ifexcessletdownshouldbeplacedinservice.f.Openletdownorificevalvesasnecessary g.PlaceTCV-130inAUTOat105'Fh.PlacePCV-135inAUTOat250psigi.AdjustchargingpumpspeedandHCV-142asnecessary Ah EOP:E-3STEAMGENERATOR TUBERUPTUREREV15PAGE30of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED35CheckVCTMakeupSystem:a.AdjustboricacidflowcontrolvalveinAUTOto9.5gpmb.Verifythefollowing:
CAUTION RCS AND RUPTURED S/G PRESSURES MUST BE MAINTAINED LESS THAN 1050 PSIG.***xx*******xxxxxxx*xx*x*xx****x*********
1)RMWmodeselectorswitchinAUTOb.Adjustcontrolsasnecessary.
*37 Control RCS Pressure And Makeup Flow To Minimize RCS-To-Secondary Leakage: a.Perform appropriate action(s)from table: PRZR LEVEL RUPTURED S/G NARROW RANGE LEVEL INCREASING DECREASING OFFSCALE HIGH LESS THAN 13%[40%ADVERSE CNMTJ BETWEEN 13%[40%ADVERSE CNMT)AND 50%BETWEEN 50%AND 75%[65%ADVERSE CNMTj GREATER THAN 75%[65%ADVERSE CNMT]o Increase RCS makeup flow o Depressurize RCS using Step 37b Depressurize RCS using Step 37b o Depressurize RCS using Step 37b o Decrease RCS makeup flow o Decrease RCS makeup flow Increase RCS makeup flow Energize PRZR heaters Energize PRZR heaters Energize PRZR heaters o Increase RCS makeup flow o Maintain RCS and ruptured S/G pressure equal Maintain RCS and ruptured S/G pressure equal Maintain RCS and ruptured S/G pressure equal Maintain RCS and ruptured S/G pressure equal b.Control pressure using normal PRZR spray, if available, to obtain desired results for Step 37a b.IF letdown is in service, THEN use auxiliary spray (AOV-296).
2)RMWcontrolarmed-REDLIGHTLITc.CheckVCTlevel:oLevel-GREATERTHAN20%-OR-oLevel-STABLEORINCREASING c.ManuallyincreaseVCTmakeupflowasfollows:1)EnsureBAtransferpumpsandRMWpumpsrunning.IFNOT,THENresetMCCCandMCCDUV~lockoutsasnecessary.
IF NOT, THEN use one PRZR PORV.
2)PlaceRMWflowcontrolvalveHCV-111inMANUALandincreaseRMWflow.3)Increaseboricacidflowasnecessary.
I')~4 N 1g'0'1I+S EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 33 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 38 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN a.Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).o AC emergency bus voltage GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED b.Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP).39 Minimize Secondary System Contamination:
I>~Mt~,M.ltCg~a~4~IPh~4 EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE31of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED36CheckChargingPumpSuctionAlignedToVCT:a.VCTlevel-GREATERTHAN20%a.IFVCTlevelcanNOTbemaintained greaterthan5%,THENperformthefollowing:
a.Isolate reject from hotwell to CST: o Place hotwell level controller (LC-107)in MANUAL at 50'.IF hotwell level increasing, THEN direct RP to sample hotwells for activity.o Verify hotwell level-STABLE b.Check status of local actions to complete ruptured S/G isolation (Refer to Attachment RUPTURED S/G) l I h EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 34 of 38 STEP ACTION/EXPECTED'ESPONSE RESPONSE NOT OBTAINED 40 Energize PRZR Heaters As Necessary To Saturate PRZR Water At Ruptured S/G Pressure 41 Check RCP Cooling: a.Check CCW to RCPs: Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).o Annunciator A-7, RCP 1A CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED b.Check RCP seal injection:
1)EnsurechargingpumpsuctionalignedtoRWSToLCV-112BopenoLCV-112Cclosed2)ContinuewithStep37.WHENVCTlevelgreaterthan40%,THENdoStep36b.b.VerifychargingpumpsalignedtoVCToLCV-112C-OPENoLCV-112B-CLOSEDb.Manuallyalignvalvesasnecessary.
o Labyrinth seal D/Ps-GREATER THAN 15 INCHES OF WATER-OR-o RCP seal injection flow to each RCP-GREATER THAN 6 GPM
Pp<<4.ig%1EP EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE32of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED**************
 
x**x*xxx*******************
EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 35 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED******xx x*0 xxxxx%xx'xx%'*x 4***x****x*******
CAUTIONRCSANDRUPTUREDS/GPRESSURES MUSTBEMAINTAINED LESSTHAN1050PSIG.***xx*******xxxxxxx*xx*x*xx****x*********
CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST, THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATION.
*37ControlRCSPressureAndMakeupFlowToMinimizeRCS-To-Secondary Leakage:a.Performappropriate action(s) fromtable:PRZRLEVELRUPTUREDS/GNARROWRANGELEVELINCREASING DECREASING OFFSCALEHIGHLESSTHAN13%[40%ADVERSECNMTJBETWEEN13%[40%ADVERSECNMT)AND50%BETWEEN50%AND75%[65%ADVERSECNMTjGREATERTHAN75%[65%ADVERSECNMT]oIncreaseRCSmakeupflowoDepressurize RCSusingStep37bDepressurize RCSusingStep37boDepressurize RCSusingStep37boDecreaseRCSmakeupflowoDecreaseRCSmakeupflowIncreaseRCSmakeupflowEnergizePRZRheatersEnergizePRZRheatersEnergizePRZRheatersoIncreaseRCSmakeupflowoMaintainRCSandrupturedS/GpressureequalMaintainRCSandrupturedS/GpressureequalMaintainRCSandrupturedS/GpressureequalMaintainRCSandrupturedS/Gpressureequalb.ControlpressureusingnormalPRZRspray,ifavailable, toobtaindesiredresultsforStep37ab.IFletdownisinservice,THENuseauxiliary spray(AOV-296).
************4*4 x x w*~************'*********42 Check RCP Status: a.RCPs-AT LEAST ONE RUNNING b.Stop all but one RCP a.Perform the following:
IFNOT,THENuseonePRZRPORV.
1)Try to start one RCP: a)Ensure conditions for starting an RCP.o Bus llA or 11B energized.
I')~4N1g'0'1I+S EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE33of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED38CheckIfEmergency D/GsShouldBeStopped:a.VerifyACemergency bussesenergized byoffsitepower:oEmergency D/GoutputbreakersOPENa.Trytorestoreoffsitepower(RefertoER-ELEC.1, RESTORATION OFOFFSITEPOWER).oACemergency busvoltageGREATERTHAN420VOLTSoACemergency busnormalfeedbreakers-CLOSEDb.Stopanyunloadedemergency D/Gandplaceinstandby(RefertoAttachment D/GSTOP).39MinimizeSecondary SystemContamination:
o Refer to Attachment RCP START.b)IF RVLIS level (no RCPs)less than 95%, THEN perform the following:
a.IsolaterejectfromhotwelltoCST:oPlacehotwelllevelcontroller (LC-107)inMANUALat50'.IFhotwelllevelincreasing, THENdirectRPtosamplehotwellsforactivity.
o Increase PRZR level to greater than 65%(80%adverse CNMTj.o Dump steam to establish RCS subcooling based on core exit T/Cs to greater than 20'F using Figure MIN SUBCOOLING.
oVerifyhotwelllevel-STABLEb.CheckstatusoflocalactionstocompleterupturedS/Gisolation (RefertoAttachment RUPTUREDS/G) lIh EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE34of38STEPACTION/EXPECTED'ESPONSE RESPONSENOTOBTAINED40EnergizePRZRHeatersAsNecessary ToSaturatePRZRWaterAtRupturedS/GPressure41CheckRCPCooling:a.CheckCCWtoRCPs:Establish normalcoolingtoRCPs(RefertoAttachment SEALCOOLING).
c)Start one RCP.2)IF an RCP can NOT be started, THEN verify natural circulation (Refer to Attachment NC).IF natural circulation can NOT be verified, THEN increase dumping steam.
oAnnunciator A-7,RCP1ACCWRETURNHIGHTEMPORLOWFLOWEXTINGUISHED oAnnunciator A-15,RCP1BCCWRETURNHIGHTEMPORLOWFLOWEXTINGUISHED b.CheckRCPsealinjection:
ig$V J~w II'gl e EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 36 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.
oLabyrinth sealD/Ps-GREATERTHAN15INCHESOFWATER-OR-oRCPsealinjection flowtoeachRCP-GREATERTHAN6GPM
43 Check If Source Range Detectors Should Be Energized:
a.Source range channels DEENERGIZED a.Go to Step 43e.b.Check intermediate range flux EITHER CHANNEL LESS THAN 10 10 AMPS b.Perform the following:
1)IF neither intermediate range channel is decreasing, THEN initiate boration.2)Continue with Step 44.WHEN flux is LESS THAN 10 amps on any operable channel, THEN do Steps 43c through e.c.Check the following:
o Both intermediate range channels-LESS THAN 10 10 AMPS c.Continue with Step 44.WHEN either condition met, THEN do Steps 43d and e.-OR-o Greater than 20 minutes since reactor trip d.Verify source range detectors ENERGIZED d.Manually energize source range detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).IF source ranges can'OT be restored, THEN refer to ER-NIS.1, SR MALFUNCTION and go to Step 44.e.Transfer Rk-45 recorder to one source range and one intermediate range channel I 4Q A~
EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 37 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 44 Establish Normal Shutdown Alignment:
a.Check condenser-AVAILABLE a.Dispatch AO to perform Attachment SD-2.b.Perform the following:
i o Open generator disconnects
~1G13A71~9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o Rotate reheater steam supply controller cam to close valves o Place reheater dump valve switches to HAND o Stop all but one condensate pump c.Verify adequate Rx head cooling: 1)Check IA to CNMT-AVAILABLE 2)Verify at least one control rod shroud fan-RUNNING 3)Verify one Rx compartment cooling fan-RUNNING 1)Go to Step 45.2)Manually start one fan as power supply permits (45 kw)3)Perform the following:
o Dispatch AO to reset UV relays at MCC C and MCC D.o Manually start one fan as power supply permits (23 kw)d.Verify Attachment SD-1-COMPLETE
~m ,~~l~l, EOP: E-3 LITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 38 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 45 Consult TSC To Determine Appropriate Post-SGTR Cooldown Procedure:
o Go to ES-3.1, POST-SGTR COOLDOWN USING BACKFILL, Step 1-OR-o Go to ES-3.2, POST-SGTR COOLDOWN USING BLOWDOWN, Step 1-OR-o Go to ES-'3.3, POST-SGTR COOLDOWN USING STEAM DUMP, Step 1-END-
~lt 4 elhi 7 X EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 1 of 1 E-3 APPENDIX LIST TITLE 1)RED PATH
 
==SUMMARY==
2)FIGURE MIN SUBCOOLING 3)ATTACHMENT CNMT RECIRC FANS 4)ATTACHMENT D/G STOP 5)ATTACHMENT N2 PORVS 6)ATTACHMENT NC 7)ATTACHMENT SEAL COOLING 8)ATTACHMENT RCP START 9)ATTACHMENT RUPTURED S/G 10)ATTACHMENT SD-1 11)ATTACHMENT SD-2 12)ATTACHMENT AUX BLDG SW 13)FOLDOUT PAGES 4
EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 1 of 1 RED PATH


EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE35of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED******xxx*0xxxxx%xx'xx%'*x 4***x****x*******
==SUMMARY==
CAUTIONIFRCPSEALCOOLINGHADPREVIOUSLY BEENLOST,THENTHEAFFECTEDRCPSHOULDNOTBESTARTEDPRIORTOASTATUSEVALUATION.
a.SUBCRITICALITY
************4*4xxw*~************'*********42CheckRCPStatus:a.RCPs-ATLEASTONERUNNINGb.StopallbutoneRCPa.Performthefollowing:
-Nuclear power greater than 5~b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than 43~~[464 adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[25<adverse CNMT]AND total feedwater flow less than 200 gpm d.INTEGRITY-Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT
1)TrytostartoneRCP:a)Ensureconditions forstartinganRCP.oBusllAor11Benergized.
-CNMT pressure greater than 60 psig
oRefertoAttachment RCPSTART.b)IFRVLISlevel(noRCPs)lessthan95%,THENperformthefollowing:
'p V',II Ijf r'-Il+~" I'~f c I, I~4 EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below t'-]Core Exit T/C Indication RC 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 S PRESSURE (PSIG)RCS PRESSURE INCREMENTS 20 PSIG SUBCOOLED REGION E C DV ERS NORMAL CNMT INADEQUATE SUBCOOLING REGION TEMPERATURE INCREMENTS 10'F 200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEMPERATURE
oIncreasePRZRleveltogreaterthan65%(80%adverseCNMTj.oDumpsteamtoestablish RCSsubcooling basedoncoreexitT/Cstogreaterthan20'FusingFigureMINSUBCOOLING.
c)StartoneRCP.2)IFanRCPcanNOTbestarted,THENverifynaturalcirculation (RefertoAttachment NC).IFnaturalcirculation canNOTbeverified, THENincreasedumpingsteam.
ig$VJ~wII'gle EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE36of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDNOTE:AdverseCNMTconditions orlossofforcedaircoolingmayresultinfailureofNISdetectors.
43CheckIfSourceRangeDetectors ShouldBeEnergized:
a.SourcerangechannelsDEENERGIZED a.GotoStep43e.b.Checkintermediate rangefluxEITHERCHANNELLESSTHAN1010AMPSb.Performthefollowing:
1)IFneitherintermediate rangechannelisdecreasing, THENinitiateboration.
2)ContinuewithStep44.WHENfluxisLESSTHAN10ampsonanyoperablechannel,THENdoSteps43cthroughe.c.Checkthefollowing:
oBothintermediate rangechannels-LESSTHAN1010AMPSc.ContinuewithStep44.WHENeithercondition met,THENdoSteps43dande.-OR-oGreaterthan20minutessincereactortripd.Verifysourcerangedetectors ENERGIZED d.Manuallyenergizesourcerangedetectors bydepressing P-6permissive defeatpushbuttons (2of2).IFsourcerangescan'OTberestored, THENrefertoER-NIS.1, SRMALFUNCTION andgotoStep44.e.TransferRk-45recordertoonesourcerangeandoneintermediate rangechannel I4QA~
EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV:15PAGE37of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED44Establish NormalShutdownAlignment:
a.Checkcondenser
-AVAILABLE a.DispatchAOtoperformAttachment SD-2.b.Performthefollowing:
ioOpengenerator disconnects
~1G13A71~9X13A73oPlacevoltageregulator toOFFoOpenturbinedrainvalvesoRotatereheatersteamsupplycontroller camtoclosevalvesoPlacereheaterdumpvalveswitchestoHANDoStopallbutonecondensate pumpc.VerifyadequateRxheadcooling:1)CheckIAtoCNMT-AVAILABLE 2)Verifyatleastonecontrolrodshroudfan-RUNNING3)VerifyoneRxcompartment coolingfan-RUNNING1)GotoStep45.2)Manuallystartonefanaspowersupplypermits(45kw)3)Performthefollowing:
oDispatchAOtoresetUVrelaysatMCCCandMCCD.oManuallystartonefanaspowersupplypermits(23kw)d.VerifyAttachment SD-1-COMPLETE
~m,~~l~l, EOP:E-3LITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE38of38STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED45ConsultTSCToDetermine Appropriate Post-SGTR CooldownProcedure:
oGotoES-3.1,POST-SGTR COOLDOWNUSINGBACKFILL, Step1-OR-oGotoES-3.2,POST-SGTR COOLDOWNUSINGBLOWDOWN, Step1-OR-oGotoES-'3.3,POST-SGTR COOLDOWNUSINGSTEAMDUMP,Step1-END-
~lt4elhi7X EOP:E-3STEAMGENERATOR TUBERUPTUREREV15PAGE1of1E-3APPENDIXLISTTITLE1)REDPATHSUMMARY2)FIGUREMINSUBCOOLING 3)ATTACHMENT CNMTRECIRCFANS4)ATTACHMENT D/GSTOP5)ATTACHMENT N2PORVS6)ATTACHMENT NC7)ATTACHMENT SEALCOOLING8)ATTACHMENT RCPSTART9)ATTACHMENT RUPTUREDS/G10)ATTACHMENT SD-111)ATTACHMENT SD-212)ATTACHMENT AUXBLDGSW13)FOLDOUTPAGES 4
EOP:E-3STEAMGENERATOR TUBERUPTUREREV15PAGE1of1REDPATHSUMMARYa.SUBCRITICALITY
-Nuclearpowergreaterthan5~b.CORECOOLING-CoreexitT/Csgreaterthan1200'F-OR-CoreexitT/Csgreaterthan700'FANDRVLISlevel(noRCPs)lessthan43~~[464adverseCNMT]c.HEATSINK-NarrowrangelevelinallS/Gslessthan54[25<adverseCNMT]ANDtotalfeedwater flowlessthan200gpmd.INTEGRITY
-Coldlegtemperatures decreasegreaterthan100'Finlast60minutesANDRCScoldlegtemperature lessthan285'Fe.CONTAINMENT
-CNMTpressuregreaterthan60psig
'pV',IIIjfr'-Il+~"I'~fcI,I~4 EOP:E-3TITLE:STEAMGENERATOR TUBERUPTUREREV15PAGE1of1FIGUREMINSUBCOOLING NOTE:Subcooling Margin=Saturation Temperature FromFigureBelowt'-]CoreExitT/CIndication RC2500240023002200210020001900180017001600140013001200110010009008007006005004003002001000SPRESSURE(PSIG)RCSPRESSUREINCREMENTS 20PSIGSUBCOOLED REGIONECDVERSNORMALCNMTINADEQUATE SUBCOOLING REGIONTEMPERATURE INCREMENTS 10'F200250300350400450500550600650700COREEXITSATURATION TEMPERATURE
(')
(')
J'-
J'-
EOP:E-3STEAMGENERATOR TUBERUPTUREREV:15PAGE1of1SIREINITIATION CRITERIAFOLDOUTPAGEIFeithercondition listedbelowoccurs,THENoperateSIpumpsmanuallyasnecessary andgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1:oRCSsubcooling basedoncoreexitT/Cs-LESSTHAN0FUSINGREQUIREMENTS OFFIGUREMINSUBCOOLING.
EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 1 of 1 SI REINITIATION CRITERIA FOLDOUT PAGE IF either condition listed below occurs, THEN operate SI pumps manually as necessary and go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1: o RCS subcooling based on core exit T/Cs-LESS THAN 0 F USING REQUIREMENTS OF FIGURE MIN SUBCOOLING.
OR24oPRZRlevel-CHARGINGCANNOTCONTROLLEVELGREATERTHAN5%[304adverseCNMT).SECONDARY INTEGRITY CRITERIAIFanyS/Gpressureisdecreasing inanuncontrolled manneroriscompletely depressurized ANDhasnotbeenisolated, THENgotoE-2,FAULTEDS/GISOLATION, Step1.3~COLDLEGRECIRCULATION SWITCHOVER CRITERION 4.5.IFRWSTleveldecreases tolessthan284,THENgotoES-1.3,TRANSFERTOCOLDLEGRECIRCULATION, Stepl.AFWSUPPLYSWITCHOVER CRITERION IFCSTleveldecreases tolessthan5feet,THENswitchtoalternate AFWwatersupply(RefertoER-AFW.1, ALTERNATE WATERSUPPLYTOAFWPUMPS).MULTIPLESGTUBERUPTURECRITERIAIFanyintactS/Glevelincreases ininanuncontrolled mannerORIFanyintactS/Ghasabnormalradiation, THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLED RECOVERYDESIRED,Step1.
OR 2 4 o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%[304 adverse CNMT).SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2, FAULTED S/G ISOLATION, Step 1.3~COLD LEG RECIRCULATION SWITCHOVER CRITERION 4.5.IF RWST level decreases to less than 284, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step l.AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).MULTIPLE S G TUBE RUPTURE CRITERIA IF any intact S/G level increases in in an uncontrolled manner OR IF any intact S/G has abnormal radiation, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.
tel5t EOP:ECA-2'T1TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE1of31ROCHESTER GASANDELECTRICCORPORATION GINNASTATIONCONTROLLED COPYNUMBERRES0SIBLEMANAGEREFFECTIVE DATECATEGORY1.0REVIEWEDBY
tel 5t EOP: ECA-2'T1TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 31 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER RES 0 SIBLE MANAGER EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY
 
EOP: ECA-2-1 TLTLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 2 of 31 A.PURPOSE-This procedure provides actions to mitigate and minimize a loss of secondary coolant from both steam generators.
B.ENTRY CONDITIONS/SYMPTOMS 1-ENTRY CONDITIONS
-This procedure is entered from: a.E-2, FAULTED STEAM GENERATOR ISOLATION, when an uncontrolled depressurization of both steam generators occurs.
 
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATZON OF BOTH STEAM GENERATORS REV: 12 PAGE 3 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF THE TDAFW PUMP IS THE ONLY AVAILABLE SOURCE OF FEED FLOW, THEN STEAM SUPPLY TO THE TDAFW PUMP MUST BE MAINTAINED FROM ONE S/G.*****************************************NOTE: o FOLDOUT page should be open AND monitored periodically.
o Conditions should be evaluated for Site Contingency Reporting (Refer to EPIP 1-0, GINNA STATION EVENT EVALUATION AND CLASSIFICATION).
o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+R/hr.1 Check Secondary Pressure Boundary: o MSIVs-CLOSED o MFW flow control valves-CLOSED~MFW regulating valves~MFW bypass valves o MFW pump discharge valves CLOSED V o S/G blowdown and sample valves CLOSED Manually close valves one loop at a time.IF valves can NOT be closed, THEN dispatch AO to locally isolate flowpaths, as necessary, one loop at a time.o TDAFW pump steam supply valves PULL STOP o TDAFW pump flow control valves CLOSED o S/G ARVs-CLOSED o Dispatch AO to locally isolate S/Gs (Refer to Attachment FAULTED S/G)


EOP:ECA-2-1TLTLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE2of31A.PURPOSE-Thisprocedure providesactionstomitigateandminimizealossofsecondary coolantfrombothsteamgenerators.
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 4 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION A MINIMUM FEED FLOW OF 50 GPM MUST BE MAINTAINED TO EACH S/G WITH A NARROW RANGE LEVEL LESS THAN 5%[25%ADVERSE CNMT].*****************************************2 Control Feed Flow To Minimize RCS Cooldown: a.Check cooldown rate in RCS cold legs-'ESS THAN 100'F/HR b.Check narrow range level in both S/Gs-LESS THAN 50%a.Decrease feed flow to 50 gpm to each S/G and go to Step 2c.b.Control feed flow to maintain narrow range level less than 50%in both S/Gs.c.Check RCS hot leg temperatures STABLE OR DECREASING c.Control feed flow or dump steam to stabilize RCS hot leg temperatures.
B.ENTRYCONDITIONS/SYMPTOMS 1-ENTRYCONDITIONS
3 Check If RCPs Should Be Stopped: a.RCP status-ANY RCP RUNNING b.SI pumps-AT LEAST TWO RUNNING c.RCS pressure minus maximum S/G pressure-LESS THAN 175 psig[400 psig adverse CNMT]d.Stop both RCPs a.Go to Step 4.b.Go to Step 4.'.Go to Step 4.  
-Thisprocedure isenteredfrom:a.E-2,FAULTEDSTEAMGENERATOR ISOLATION, whenanuncontrolled depressurization ofbothsteamgenerators occurs.  


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATZON OFBOTHSTEAMGENERATORS REV:12PAGE3of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************CAUTIONIFTHETDAFWPUMPISTHEONLYAVAILABLE SOURCEOFFEEDFLOW,THENSTEAMSUPPLYTOTHETDAFWPUMPMUSTBEMAINTAINED FROMONES/G.*****************************************NOTE:oFOLDOUTpageshouldbeopenANDmonitored periodically.
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 5 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Check CST Level-GREATER THAN 5 FEET'witch to alternate AFW suction supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).*****************************************CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 5B).*5 Monitor PRZR PORVs And Block Valves: a.Power to PORV block valves AVAILABLE b.PORVs-CLOSED a.Restore power to block valves unless block valve was closed to isolate an open PORV:~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C b.IF PRZR pressure less than 2335 psig, THEN manually close PORVs.c.Block valves-AT LEAST ONE OPEN IF any PORV can NOT be closed, THEN manually close its block valve.IF block valve can NOT be closed, THEN dispatch AO to locally check breaker.~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C c.'Open one block valve unless it was closed to isolate an open PORV.  
oConditions shouldbeevaluated forSiteContingency Reporting (RefertoEPIP1-0,GINNASTATIONEVENTEVALUATION ANDCLASSIFICATION).
oAdverseCNMTvaluesshouldbeusedwheneverCNMTpressureisgreaterthan4psigorCNMTradiation isgreaterthan10+R/hr.1CheckSecondary PressureBoundary:
oMSIVs-CLOSEDoMFWflowcontrolvalves-CLOSED~MFWregulating valves~MFWbypassvalvesoMFWpumpdischarge valvesCLOSEDVoS/GblowdownandsamplevalvesCLOSEDManuallyclosevalvesoneloopatatime.IFvalvescanNOTbeclosed,THENdispatchAOtolocallyisolateflowpaths, asnecessary, oneloopatatime.oTDAFWpumpsteamsupplyvalvesPULLSTOPoTDAFWpumpflowcontrolvalvesCLOSEDoS/GARVs-CLOSEDoDispatchAOtolocallyisolateS/Gs(RefertoAttachment FAULTEDS/G)


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE4of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************CAUTIONAMINIMUMFEEDFLOWOF50GPMMUSTBEMAINTAINED TOEACHS/GWITHANARROWRANGELEVELLESSTHAN5%[25%ADVERSECNMT].*****************************************2ControlFeedFlowToMinimizeRCSCooldown:
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 6 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 6 Check Secondary Radiation Levels-NORMAL o Steamline radiation monitor (R-31 and R-32)o Dispatch AO to locally check steamline radiation Go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.o Request RP sample S/Gs for activity*****************************************CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
a.CheckcooldownrateinRCScoldlegs-'ESSTHAN100'F/HRb.ChecknarrowrangelevelinbothS/Gs-LESSTHAN50%a.Decreasefeedflowto50gpmtoeachS/GandgotoStep2c.b.Controlfeedflowtomaintainnarrowrangelevellessthan50%inbothS/Gs.c.CheckRCShotlegtemperatures STABLEORDECREASING c.Controlfeedflowordumpsteamtostabilize RCShotlegtemperatures.
7 Reset SI
3CheckIfRCPsShouldBeStopped:a.RCPstatus-ANYRCPRUNNINGb.SIpumps-ATLEASTTWORUNNINGc.RCSpressureminusmaximumS/Gpressure-LESSTHAN175psig[400psigadverseCNMT]d.StopbothRCPsa.GotoStep4.b.GotoStep4.'.GotoStep4.


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE5of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED4CheckCSTLevel-GREATERTHAN5FEET'witchtoalternate AFWsuctionsupply(RefertoER-AFW.1, ALTERNATE WATERSUPPLYTOAFWPUMPS).*****************************************CAUTIONIFANYPRZRPORVOPENSBECAUSEOFHIGHPRZRPRESSURE, ITSHOULDBECLOSEDAFTERPRESSUREDECREASES TOLESSTHAN2335PSIG(REFERTOSTEP5B).*5MonitorPRZRPORVsAndBlockValves:a.PowertoPORVblockvalvesAVAILABLE b.PORVs-CLOSEDa.RestorepowertoblockvalvesunlessblockvalvewasclosedtoisolateanopenPORV:~MOV-515,MCCCposition6C~MOV-516,MCCDposition6Cb.IFPRZRpressurelessthan2335psig,THENmanuallyclosePORVs.c.Blockvalves-ATLEASTONEOPENIFanyPORVcanNOTbeclosed,THENmanuallycloseitsblockvalve.IFblockvalvecanNOTbeclosed,THENdispatchAOtolocallycheckbreaker.~MOV-515,MCCCposition6C~MOV-516,MCCDposition6Cc.'OpenoneblockvalveunlessitwasclosedtoisolateanopenPORV.  
EOP: ECA-2~1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV 12 PAGE 7 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION RCS PRESSURE SHOULD BE MONITORED.
IF.RCS PRESSURE DECREASES TO LESS THAN 250 PSIG[465 PSIG ADVERSE CNMT], THEN THE RHR PUMPS MUST BE MANUALLY RESTARTED TO SUPPLY WATER TO THE RCS.*8 Monitor If RHR Pumps Should Be Stopped: a.RHR pumps-ANY RUNNING b.Check RCS Pressure: a.Go to Step 9.1)Pressure-GREATER THAN 250 psig[465 psig adverse CNMT]2)Pressure-STABLE OR INCREASING 1)Go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step 1.2)Go to Step 9.c.Stop RHR pumps and place in AUTO


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE6of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED6CheckSecondary Radiation Levels-NORMALoSteamline radiation monitor(R-31andR-32)oDispatchAOtolocallychecksteamline radiation GotoE-3,STEAMGENERATOR TUBERUPTURE,Stepl.oRequestRPsampleS/Gsforactivity*****************************************CAUTIONIFOFFSITEPOWERISLOSTAFTERSIRESET,THENSELECTEDSWPUMPSANDONECCWPUMPWILLAUTOSTARTONEMERGENCY D/G.MANUALACTIONWILLBEREQUIREDTORESTARTSAFEGUARDS EQUIPMENT.
EOP: ECA-2~1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 8 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*9 Monitor If CNMT Spray Should Be Stopped: a.CNMT spray pumps-RUNNING b.Check the following:
7ResetSI
o CNMT pressure-LESS THAN 4 PSIG a.Go to Step 10.b.Continue with Step 10.WHEN BOTH conditions satisfied, THEN do Steps 9c through f.o Sodium hydroxide tank level LESS THAN 55%c.Reset CNMT spray d.Check NaOH tank outlet valves CLOSED~AOV-836A~AOV-836B d.Place NaOH tank outlet valve controllers to MANUAL and close valves.~AOV-836A~AOV-836B e.Stop CNMT spray pumps and place in AUTO f.Close CNMT spray pump discharge valves~MOV-860A~MOV-860B~MOV-860C~MOV-860D, l~
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 9 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 10 Check RWST Level-GREATER THAN 284 Go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step l.ll Reset CI: a.Depress CI reset pushbutton b.Verify annunciator A-26, CNMT ISOLATION-EXTINGUISHED b.Perform the following:
1)Reset SI.2)Depress CI reset pushbutton.
12 Verify Adequate SW Flow: a.Check at least two SW pumps RUNNING a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN perform the following:
1),Ensure SW isolation.
2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)3)Go to Step 14.


EOP:ECA-2~1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV12PAGE7of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************CAUTIONRCSPRESSURESHOULDBEMONITORED.
EOP: ECA-2.1 T!TLE: UNCONTROLLED DEPRESSURXZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 10 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Establish IA to CNMT: a.Verify non-safeguards busses energized from offsite power o Bus 13 normal feed-CLOSED-OR-o Bus 15 normal feed-CLOSED b.Verify SW isolation valves to turbine building-OPEN~MOV-4613 and MOV-4670~MOV-4614 and MOV-4664 c.Verify at least two air compressors
IF.RCSPRESSUREDECREASES TOLESSTHAN250PSIG[465PSIGADVERSECNMT],THENTHERHRPUMPSMUSTBEMANUALLYRESTARTED TOSUPPLYWATERTOTHERCS.*8MonitorIfRHRPumpsShouldBeStopped:a.RHRpumps-ANYRUNNINGb.CheckRCSPressure:
-RUNNING d.Check IA supply: o Pressure-GREATER THAN 60 PSIG o Pressure-STABLE OR INCREASING e.Reset both trains of XY relays for IA to CNMT AOV-5392 f.Verify IA to CNMT AOV-5392-OPEN a.Perform the following:
a.GotoStep9.1)Pressure-GREATERTHAN250psig[465psigadverseCNMT]2)Pressure-STABLEORINCREASING 1)GotoE-l,LOSSOFREACTORORSECONDARY COOLANT,Step1.2)GotoStep9.c.StopRHRpumpsandplaceinAUTO
1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Verify adequate emergency D/G capacity to run air compressors (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans should be stopped (Refer to Attachment CNMT RECIRC FANS).3)WHEN bus 15 restored, THEN reset control room lighting.b.Manually align valves.c.Manually start air compressors as power supply permits (75 kw each).IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.
d.Perform the following:
1)C'ontinue attempts to restore IA (Refer,to AP-IA.1, LOSS OF INSTRUMENT AIR).2)Continue with Step 14.WHEN IA restored, THEN do Steps 13e and f.  


EOP:ECA-2~1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE8of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*9MonitorIfCNMTSprayShouldBeStopped:a.CNMTspraypumps-RUNNINGb.Checkthefollowing:
EOP: ECA-2'T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 11 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 14 Check If SI ACCUMs Should Be Isolated: a.Both RCS hot leg temperatures LESS THAN 400'F a.Go to Step 15.b.Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves~MOV-841, MCC C position 12F~MOV-865, MCC D position 12C c.Close SI ACCUM discharge valves~MOV-841~MOV-865 c.Vent any unisolated ACCUMs: 1)Open vent valves for unisolated SI ACCUMs,~ACCUM A, AOV-834A~ACCUM B, AOV-834B d.Locally reopen breakers for MOV-841 and MOV-865 2)Open HCV-945.15 Check Normal Power Available To Charging Pumps: o Bus 14 normal feed breaker CLOSED o Bus 16 normal feed breaker-CLOSED Verify adequate emergency D/G capacity to run charging pumps (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans can be stopped (Refer to.Attachment CNMT RECIRC FANS).  
oCNMTpressure-LESSTHAN4PSIGa.GotoStep10.b.ContinuewithStep10.WHENBOTHconditions satisfied, THENdoSteps9cthroughf.oSodiumhydroxide tanklevelLESSTHAN55%c.ResetCNMTsprayd.CheckNaOHtankoutletvalvesCLOSED~AOV-836A~AOV-836Bd.PlaceNaOHtankoutletvalvecontrollers toMANUALandclosevalves.~AOV-836A~AOV-836Be.StopCNMTspraypumpsandplaceinAUTOf.CloseCNMTspraypumpdischarge valves~MOV-860A~MOV-860B~MOV-860C~MOV-860D, l~
EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE9of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED10CheckRWSTLevel-GREATERTHAN284GotoES-1.3,TRANSFERTOCOLDLEGRECIRCULATION, Stepl.llResetCI:a.DepressCIresetpushbutton b.Verifyannunciator A-26,CNMTISOLATION
-EXTINGUISHED b.Performthefollowing:
1)ResetSI.2)DepressCIresetpushbutton.
12VerifyAdequateSWFlow:a.CheckatleasttwoSWpumpsRUNNINGa.ManuallystartSWpumpsaspowersupplypermits(258kweach).IFlessthantwoSWpumpsrunning,THENperformthefollowing:
1),Ensure SWisolation.
2)DispatchAOtoestablish normalshutdownalignment (RefertoAttachment SD-1)b.DispatchAOtoestablish normalshutdownalignment (RefertoAttachment SD-1)3)GotoStep14.  


EOP:ECA-2.1T!TLE:UNCONTROLLED DEPRESSURXZATION OFBOTHSTEAMGENERATORS REV:12PAGE10of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED13Establish IAtoCNMT:a.Verifynon-safeguards bussesenergized fromoffsitepoweroBus13normalfeed-CLOSED-OR-oBus15normalfeed-CLOSEDb.VerifySWisolation valvestoturbinebuilding-OPEN~MOV-4613andMOV-4670~MOV-4614andMOV-4664c.Verifyatleasttwoaircompressors
EOP;ECA-2.1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 12 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 16 Check If Charging Flow Has Been Established:
-RUNNINGd.CheckIAsupply:oPressure-GREATERTHAN60PSIGoPressure-STABLEORINCREASING e.ResetbothtrainsofXYrelaysforIAtoCNMTAOV-5392f.VerifyIAtoCNMTAOV-5392-OPENa.Performthefollowing:
a.Charging pumps-ANY RUNNING a.Perform the following:
1)Closenon-safeguards bustiebreakers:
1)IF CCW flow is lost to any RCP thermal barrier OR any RCP&#xb9;1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal injection needle valve(s)to affected RCP:~RCP A, V-300A~RCP B, V-300B 2)Ensure HCV-142 open, demand at Oa.b.Align charging pump suction to RWST: o LCV-112B-OPEN o LCV-112C-CLOSED b.IF LCV-112B can NOT be opened, THEN perform the following:
~Bus13toBus14tie~Bus15toBus16tie2)Verifyadequateemergency D/Gcapacitytorunaircompressors (75kweach).IFNOT,THENevaluateifCNMTRECIRCfansshouldbestopped(RefertoAttachment CNMTRECIRCFANS).3)WHENbus15restored, THENresetcontrolroomlighting.
1)Verify charging pump A NOT running and place in PULL STOP.c.Start charging pumps as'ecessary and adjust charging flow to restore PRZR level 2)Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).3)WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).  
b.Manuallyalignvalves.c.Manuallystartaircompressors aspowersupplypermits(75kweach).IFaircompressors canNOTbestarted,THENdispatchAOtolocallyresetcompressors asnecessary.
d.Performthefollowing:
1)C'ontinue attemptstorestoreIA(Refer,to AP-IA.1,LOSSOFINSTRUMENT AIR).2)ContinuewithStep14.WHENIArestored, THENdoSteps13eandf.  


EOP:ECA-2'T!TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE11of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED14CheckIfSIACCUMsShouldBeIsolated:
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 13 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*17 Monitor SI Termination Criteria: a.SI pumps-ANY RUNNING b.Check RCS pressure: o Pressure-GREATER THAN 1625 psig[1825 psig adverse CNMT]o Pressure-STABLE OR INCREASING a.Go to Step 19.b.DO NOT stop SI pumps'~, Perform the following:
a.BothRCShotlegtemperatures LESSTHAN400'Fa.GotoStep15.b.DispatchAOwithlockedvalvekeytolocallyclosebreakersforSIACCUMdischarge valves~MOV-841,MCCCposition12F~MOV-865,MCCDposition12Cc.CloseSIACCUMdischarge valves~MOV-841~MOV-865c.Ventanyunisolated ACCUMs:1)Openventvalvesforunisolated SIACCUMs,~ACCUMA,AOV-834A~ACCUMB,AOV-834Bd.LocallyreopenbreakersforMOV-841andMOV-8652)OpenHCV-945.15CheckNormalPowerAvailable ToChargingPumps:oBus14normalfeedbreakerCLOSEDoBus16normalfeedbreaker-CLOSEDVerifyadequateemergency D/Gcapacitytorunchargingpumps(75kweach).IFNOT,THENevaluateifCNMTRECIRCfanscanbestopped(Referto.Attachment CNMTRECIRCFANS).  
1)Energize PRZR heaters and operate PRZR spray as necessary to stabilize RCS pressure greater than 1625 psig[1825 psig adverse CNMT)c.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING 2)Return to Step 2.c.DO NOT stop SI pumps.Return to Step 2.d.PRZR level-GREATER THAN 5%[30%adverse CNMT)d.Do NOT stop SI pumps.Perform the following:
1)IF normal'PRZR spray available, THEN try to stabilize RCS pressure with PRZR spray, 2)Return to Step 17a.NOTE: Foldout Page E-2 transition criteria does not apply while performing steps 18 and 19.18 Stop SI and RHR Pumps And Place In Auto


EOP;ECA-2.1T!TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE12of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED16CheckIfChargingFlowHasBeenEstablished:
EOP: ECA 2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 14 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*19 Monitor SI Reinitiation Criteria: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Manually operate SI pumps as necessary and return to Step 2.b.PRZR level-GREATER THAN 5%[30%adverse CNMT]b.Control charging flow to maintain PRZR level.IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary and return to Step 2.20 Check RCS Hot Leg Temperatures
a.Chargingpumps-ANYRUNNINGa.Performthefollowing:
-STABLE OR DECREASING Control feed flow or dump steam to stabilize RCS hot leg temperatures.
1)IFCCWflowislosttoanyRCPthermalbarrierORanyRCP&#xb9;1sealoutlettemperature offscalehigh,THENdispatchAOwithkeytoRWSTgatetoclosesealinjection needlevalve(s)toaffectedRCP:~RCPA,V-300A~RCPB,V-300B2)EnsureHCV-142open,demandatOa.b.AlignchargingpumpsuctiontoRWST:oLCV-112B-OPENoLCV-112C-CLOSEDb.IFLCV-112BcanNOTbeopened,THENperformthefollowing:
21 Check Narrow Range Level In Both S/Gs-LESS THAN 504 Control feed flow to maintain narrow range level less than 50%in both S/Gs.22 Verify Adequate SW Flow To CCW Hx: a.Verify at least two SW pumps RUNNING b.Verify AUX BLDG SW isolation valves-OPEN~MOV-4615 and MOV-4734~MOV-4616 and MOV-4735 a.Manually start pumps as power supply permits (258 kw per pump).IF less than two SW pumps can be operated, THEN go to Step 28'.Establish SW to AUX BLDG (Refer to Attachment AUX BLDG SW).c.Verify CNMT RECIRC fan annunciator C-2, HIGH TEMPERATURE AIARM-EXTINGUISHED c.Dispatch AO to locally throttle flow to CCW Hx to between 5000 gpm and 6000 gpm total flow.  
1)VerifychargingpumpANOTrunningandplaceinPULLSTOP.c.Startchargingpumpsas'ecessary andadjustchargingflowtorestorePRZRlevel2)DispatchAOtolocallyopenmanualchargingpumpsuctionfromRWST(V-358locatedinchargingpumproom).3)WHENV-358open,THENdirectAOtocloseV-268toisolatechargingpumpsBandCfromVCT(V-268locatedinchargingpumproom).  


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE13of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*17MonitorSITermination Criteria:
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 15 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 23 Check If Normal CVCS Operation Can Be Established a.Verify IA restored: o IA to CNMT (AOV-5392)
a.SIpumps-ANYRUNNINGb.CheckRCSpressure:
-OPEN o IA pressure-GREATER THAN 60 PSIG a.Continue with Step 28.WHEN IA restored, THEN do Steps 23 through 27.b.Verify instrument bus D-ENERGIZED b.Energize MCC B.IF MCC B NOT available, THEN perform the following:
oPressure-GREATERTHAN1625psig[1825psigadverseCNMT]oPressure-STABLEORINCREASING a.GotoStep19.b.DONOTstopSIpumps'~,Performthefollowing:
c.CCW pumps-ANY RUNNING d.Charging pump-ANY RUNNING 1)Verify MCC A energized.
1)EnergizePRZRheatersandoperatePRZRsprayasnecessary tostabilize RCSpressuregreaterthan1625psig[1825psigadverseCNMT)c.RCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING 2)ReturntoStep2.c.DONOTstopSIpumps.ReturntoStep2.d.PRZRlevel-GREATERTHAN5%[30%adverseCNMT)d.DoNOTstopSIpumps.Performthefollowing:
2)Place instrument bus D on maintenance supply.c.Perform the following:
1)IFnormal'PRZRsprayavailable, THENtrytostabilize RCSpressurewithPRZRspray,2)ReturntoStep17a.NOTE:FoldoutPageE-2transition criteriadoesnotapplywhileperforming steps18and19.18StopSIandRHRPumpsAndPlaceInAuto
1)IF any RCP&#xb9;1 seal outlet temperature of f scale high, THEN isolate CCW to thermal barrier of affected RCP(s).~RCP A, MOV-749A and MOV-759A~RCP B, MOV-749B and MOV-759B 2)Manually start one CCW pump.d.Continue with Step 28.WHEN any charging pump running, THEN do Steps 24 through 27.  


EOP:ECA2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE14of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*19MonitorSIReinitiation Criteria:
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 16 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 24 Verify PRZR Level-GREATER THAN 134[40%adverse CNMT]Continue with Step 26.WHEN PRZR level increases to greater than 13%[40%adverse CNMT], THEN do Step 25.25 Establish Normal Letdown: a.Verify charging line flow to REGEN Hx-GREATER THAN 20 GPM b.Place the following switches to CLOSE:~Letdown orifice'valves (AOV-200A, AOV-200B, and AOV-202)~AOV-371, letdown isolation valve~AOV-427, loop B cold leg to REGEN Hx c.Place letdown controllers in MANUAL at 40%open~TCV-130~PCV-135 d.Reset both trains of XY relays for AOV-371 and AOV-427 e.Open AOV-371 and AOV-427 IF RCP seal return has been established, THEN establish excess letdown as follows: o Place excess letdown divert valve, AOV-312, to NORMAL.o Ensure CCW from excess letdown open, (AOV-745).
a.RCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING a.ManuallyoperateSIpumpsasnecessary andreturntoStep2.b.PRZRlevel-GREATERTHAN5%[30%adverseCNMT]b.ControlchargingflowtomaintainPRZRlevel.IFPRZRlevelcanNOTbemaintained, THENmanuallyoperateSIpumpsasnecessary andreturntoStep2.20CheckRCSHotLegTemperatures
o Open excess letdown isolation'alve AOV-310.o Slowly open HCV-123 to maintain excess letdown temperature less than 195'F and pressure less than 100 psig.o Adjust charging pump speed as necessary.
-STABLEORDECREASING Controlfeedflowordumpsteamtostabilize RCShotlegtemperatures.
IF RCP seal return NOT established, THEN consult TSC to determine if excess letdown should be placed in service.f.Open letdown orifice valves as necessary g.Place TCV-130 in AUTO at 105'F h.Place PCV-135 in AUTO at 250 psig i.Adjust charging pump speed and HCV-142 as necessary
21CheckNarrowRangeLevelInBothS/Gs-LESSTHAN504Controlfeedflowtomaintainnarrowrangelevellessthan50%inbothS/Gs.22VerifyAdequateSWFlowToCCWHx:a.VerifyatleasttwoSWpumpsRUNNINGb.VerifyAUXBLDGSWisolation valves-OPEN~MOV-4615andMOV-4734~MOV-4616andMOV-4735a.Manuallystartpumpsaspowersupplypermits(258kwperpump).IFlessthantwoSWpumpscanbeoperated, THENgotoStep28'.Establish SWtoAUXBLDG(RefertoAttachment AUXBLDGSW).c.VerifyCNMTRECIRCfanannunciator C-2,HIGHTEMPERATURE AIARM-EXTINGUISHED c.DispatchAOtolocallythrottleflowtoCCWHxtobetween5000gpmand6000gpmtotalflow.  


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE15of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED23CheckIfNormalCVCSOperation CanBeEstablished a.VerifyIArestored:
EOP: ECA-2.1 T1TLE UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 17 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 26 Check VCT Makeup System: a.Adjust boric acid flow control valve in AUTO to 9.5 gpm b.Adjust RMW flow control valve in AUTO to 40 gpm c.Verify the following:
oIAtoCNMT(AOV-5392)
1)RMW mode selector switch in AUTO c.Adjust controls as necessary.
-OPENoIApressure-GREATERTHAN60PSIGa.ContinuewithStep28.WHENIArestored, THENdoSteps23through27.b.Verifyinstrument busD-ENERGIZED b.EnergizeMCCB.IFMCCBNOTavailable, THENperformthefollowing:
2)RMW control armed-RED LIGHT LIT d.Check VCT level: o Level-GREATER THAN 20%-OR-o Level-STABLE OR INCREASING d.Manually increase VCT makeup flow as follows: 1)Ensure BA transfer pumps'and RMW pumps running.IF NOT, THEN reset MCC C and MCC D UV lockouts as necessary.
c.CCWpumps-ANYRUNNINGd.Chargingpump-ANYRUNNING1)VerifyMCCAenergized.
2)Place RMW flow control valve HCV-111 in MANUAL and increase RMW flow.3)Increase boric acid flow as necessary.  
2)Placeinstrument busDonmaintenance supply.c.Performthefollowing:
1)IFanyRCP&#xb9;1sealoutlettemperature offscalehigh,THENisolateCCWtothermalbarrierofaffectedRCP(s).~RCPA,MOV-749AandMOV-759A~RCPB,MOV-749BandMOV-759B2)ManuallystartoneCCWpump.d.ContinuewithStep28.WHENanychargingpumprunning,THENdoSteps24through27.  


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE16of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED24VerifyPRZRLevel-GREATERTHAN134[40%adverseCNMT]ContinuewithStep26.WHENPRZRlevelincreases togreaterthan13%[40%adverseCNMT],THENdoStep25.25Establish NormalLetdown:a.VerifycharginglineflowtoREGENHx-GREATERTHAN20GPMb.Placethefollowing switchestoCLOSE:~Letdownorifice'valves (AOV-200A, AOV-200B, andAOV-202)~AOV-371,letdownisolation valve~AOV-427,loopBcoldlegtoREGENHxc.Placeletdowncontrollers inMANUALat40%open~TCV-130~PCV-135d.ResetbothtrainsofXYrelaysforAOV-371andAOV-427e.OpenAOV-371andAOV-427IFRCPsealreturnhasbeenestablished, THENestablish excessletdownasfollows:oPlaceexcessletdowndivertvalve,AOV-312,toNORMAL.oEnsureCCWfromexcessletdownopen,(AOV-745).
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURXZATION OF BOTH STEAM GENERATORS REV 12 PAGE 18 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 27 Check Charging Pump Suction Aligned To VCT: a.VCT level-GREATER THAN 20%a.IF VCT level can NOT be maintained greater than 5%, THEN perform the following:
oOpenexcessletdownisolation
1)Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed 2)Continue with Step 28.WHEN VCT level greater than 40%, THEN do'tep'7b.
'alveAOV-310.oSlowlyopenHCV-123tomaintainexcessletdowntemperature lessthan195'Fandpressurelessthan100psig.oAdjustchargingpumpspeedasnecessary.
b.Verify charging pumps aligned to VCT: o LCV-112C-OPEN o LCV-112B-CLOSED b.Manually align valves as necessary.  
IFRCPsealreturnNOTestablished, THENconsultTSCtodetermine ifexcessletdownshouldbeplacedinservice.f.Openletdownorificevalvesasnecessary g.PlaceTCV-130inAUTOat105'Fh.PlacePCV-135inAUTOat250psigi.AdjustchargingpumpspeedandHCV-142asnecessary


EOP:ECA-2.1T1TLEUNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE17of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED26CheckVCTMakeupSystem:a.AdjustboricacidflowcontrolvalveinAUTOto9.5gpmb.AdjustRMWflowcontrolvalveinAUTOto40gpmc.Verifythefollowing:
EOP: ECA-'2.1 TITLES UNCONTROLLED DEPRESSURXZATZON OF BOTH STEAM GENERATORS REV 12 PAGE 19 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 28 Check RCP Cooling: a.Check CCW to RCPs: Establish normal cooling to RCPs~(Refer to Attachment SEAL COOLING).o Annunciator A-7, RCP lA CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED b.Check'RCP seal injection:
1)RMWmodeselectorswitchinAUTOc.Adjustcontrolsasnecessary.
o Labyrinth seal D/Ps-GREATER THAN 15 INCHES OF WATER-OR-o RCP seal injection flov to each RCP-GREATER THAN 6 GPM
2)RMWcontrolarmed-REDLIGHTLITd.CheckVCTlevel:oLevel-GREATERTHAN20%-OR-oLevel-STABLEORINCREASING d.ManuallyincreaseVCTmakeupflowasfollows:1)EnsureBAtransferpumps'andRMWpumpsrunning.IFNOT,THENresetMCCCandMCCDUVlockoutsasnecessary.
2)PlaceRMWflowcontrolvalveHCV-111inMANUALandincreaseRMWflow.3)Increaseboricacidflowasnecessary.


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURXZATION OFBOTHSTEAMGENERATORS REV12PAGE18of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED27CheckChargingPumpSuctionAlignedToVCT:a.VCTlevel-GREATERTHAN20%a.IFVCTlevelcanNOTbemaintained greaterthan5%,THENperformthefollowing:
EOP: ECA-2.1 T1TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 20 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 29 Check If Seal Return Flow Should Be Established:
1)EnsurechargingpumpsuctionalignedtoRWSToLCV-112BopenoLCV-112Cclosed2)ContinuewithStep28.WHENVCTlevelgreaterthan40%,THENdo'tep'7b.
a.Verify RCP&#xb9;1 seal outlet temperature
b.VerifychargingpumpsalignedtoVCT:oLCV-112C-OPENoLCV-112B-CLOSEDb.Manuallyalignvalvesasnecessary.  
-LESS THAN 235'F b.Verify RCP seal outlet valves OPEN a.Go to Step 30.b.Manually open valves as necessary.
~AOV-270A~AOV-270B c.Reset both trains of XY relays for RCP seal return isolation valve MOV-313 d.Open RCP seal return isolation valve MOV-313 e.Verify RCP&#xb9;1 seal leakoff flow LESS THAN 6.0 GPM d.Perform the following:
1)Place MOV-313 switch to OPEN.2)Dispatch AO with key to RWST gate to locally open MOV-313.e.Perform the following:
1)Trip the affected RCP 2)Allow 4 minutes for pump coast down, THEN close the affected RCP seal discharge valve f.Verify RCP&#xb9;1 seal leakoff flow GREATER THAN 0.8 GPM~RCP A, AOV-270A~RCP B, AOV-270B IF both RCP seal discharge valves are shut, THEN go to Step 30.f.Refer to AP-RCP.1, RCP SEAL MALFUNCTION.  


EOP:ECA-'2.1TITLESUNCONTROLLED DEPRESSURXZATZON OFBOTHSTEAMGENERATORS REV12PAGE19of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED28CheckRCPCooling:a.CheckCCWtoRCPs:Establish normalcoolingtoRCPs~(RefertoAttachment SEALCOOLING).
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 21 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.o When using PRZR PORV, select one with an operable block valve.30 Energize Heaters And Operate Normal Spray As Necessary To Maintain RCS Pressure Stable IF normal'pray NOT available and letdown is in service, THEN use auxiliary spray valve (AOV-296).
oAnnunciator A-7,RCPlACCWRETURNHIGHTEMPORLOWFLOWEXTINGUISHED oAnnunciator A-15,RCP1BCCWRETURNHIGHTEMPORLOWFLOWEXTINGUISHED b.Check'RCP sealinjection:
IF PRZR spray NOT'vailable', THEN use one PRZR PORV.IF IA NOT available, THEN refer to Attachment N2 PORVS.
oLabyrinth sealD/Ps-GREATERTHAN15INCHESOFWATER-OR-oRCPsealinjection flovtoeachRCP-GREATERTHAN6GPM
C EOP: ECA-2.1'1ILE:
UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV 12 PAGE 22 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 31 Verify All, AC Busses-ENERGIZED BY OFFSITE PONER o Normal feed breakers to all 480 volt busses-CLOSED o 480 bus voltage-GREATER THAN 420 VOLTS o Emergency D/G output breakers OPEN Perform the following:
a.IF any AC emergency bus normal feed breaker open, THEN ensure associated D/G breaker closed.b.Perform the following, as necessary:
1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~'Bus 15 to Bus 16 tie 2)Place the following pumps in PULL STOP:~EH pumps~Turning gear oil pump~HP seal oil backup pump 3)Restore power to MCCs.~A from Bus 13 4 B from Bus 15~E from Bus 15~F from Bus 15 4)WHEN bus 15 restored, THEN reset control room lighting..
5)Refer to Attachment SI/UV for other equipment lost with loss of offsite power.c.Try to restore offsite power to all AC busses (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).
I EOP: ECA-2 1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 23 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST, THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATIONS 32 Check RCP Status-'T LEAST ONE RUNNING Try to start one RCP: a.Establish conditions for starting an RCP.o Bus 11A or 11B energized I o Refer to Attachment RCP START.b.Start one RCP.IF an RCP can NOT be started, THEN verify natural circulation (Refer to Attachment NC).IF natural circulation can NOT be verified, THEN increase feed flow or dumping steam.
ilk EOP: ECA-2~1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 24 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED I NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.
33 Check If Source Range Detectors Should Be Energized:
a.Source range channels DEENERGIZED a.Go to Step 33e.b.Check intermediate, range flux-EITHER CHANNEL LESS THAN 10 10 AMPS b.Perform the following:
1)IF neither intermediate range channel is decreasing THEN initiate boration.2)Continue with Step 34.WHEN flux is LESS THAN 10 amps on any operable channel, THEN do Steps 33c, d and e.c.Check the following:
o Both intermediate range channels-LESS THAN 10-10 AMPS c.Continue with step 34.WHEN either condition met, THEN do Steps 33d and e.-OR-o Greater than 20 minutes since reactor trip d.Verify source range detectors ENERGIZED d.Manually energize source'range detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).e.Transfer Rk-45 recorder'to one source range and one intermediate range channel.IF source ranges can NOT be restored, THEN refer to ER-NIS.l, SR MALFUNCTION and go to Step 34.


EOP:ECA-2.1T1TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE20of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED29CheckIfSealReturnFlowShouldBeEstablished:
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 25 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 34 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN a.Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).o AC emergency bus voltage GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED b.Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)  
a.VerifyRCP&#xb9;1sealoutlettemperature
-LESSTHAN235'Fb.VerifyRCPsealoutletvalvesOPENa.GotoStep30.b.Manuallyopenvalvesasnecessary.
~AOV-270A~AOV-270Bc.ResetbothtrainsofXYrelaysforRCPsealreturnisolation valveMOV-313d.OpenRCPsealreturnisolation valveMOV-313e.VerifyRCP&#xb9;1sealleakoffflowLESSTHAN6.0GPMd.Performthefollowing:
1)PlaceMOV-313switchtoOPEN.2)DispatchAOwithkeytoRWSTgatetolocallyopenMOV-313.e.Performthefollowing:
1)TriptheaffectedRCP2)Allow4minutesforpumpcoastdown,THENclosetheaffectedRCPsealdischarge valvef.VerifyRCP&#xb9;1sealleakoffflowGREATERTHAN0.8GPM~RCPA,AOV-270A~RCPB,AOV-270BIFbothRCPsealdischarge valvesareshut,THENgotoStep30.f.RefertoAP-RCP.1, RCPSEALMALFUNCTION.


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE21of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDNOTE:oIfauxiliary sprayisinuse,sprayflowmaybeincreased byclosingnormalchargingvalveAOV-294andnormalPRZRsprayvalves.oWhenusingPRZRPORV,selectonewithanoperableblockvalve.30EnergizeHeatersAndOperateNormalSprayAsNecessary ToMaintainRCSPressureStableIFnormal'pray NOTavailable andletdownisinservice,THENuseauxiliary sprayvalve(AOV-296).
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 26 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 35 Establish Normal Shutdown Alignment:
IFPRZRsprayNOT'vailable',
a.Check condenser-AVAILABLE a.Dispatch AO to perform Attachment SD-2.b, Perform the following:
THENuseonePRZRPORV.IFIANOTavailable, THENrefertoAttachment N2PORVS.
o Open generator disconnects
C EOP:ECA-2.1'1ILE:
~1G13A71~9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o Rotate reheater steam supply controller cam to close valves o Place reheater dump valve switches to HAND o Stop all but one condensate pump c.Verify adequate Rx head cooling: 1)Verify at least one control rod shroud fan-RUNNING 1)Manually start one fan as power supply permits (45 kw)2)Verify one Rx compartment cooling fan-RUNNING 2)Perform the following:
UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV12PAGE22of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED31VerifyAll,ACBusses-ENERGIZED BYOFFSITEPONERoNormalfeedbreakerstoall480voltbusses-CLOSEDo480busvoltage-GREATERTHAN420VOLTSoEmergency D/GoutputbreakersOPENPerformthefollowing:
o Dispatch AO to reset UV relays at MCC C and MCC D.o Manually start one fan as power supply permits (23 kw)d.Verify Attachment SD-1-COMPLETE
a.IFanyACemergency busnormalfeedbreakeropen,THENensureassociated D/Gbreakerclosed.b.Performthefollowing, asnecessary:
1)Closenon-safeguards bustiebreakers:
~Bus13toBus14tie~'Bus15toBus16tie2)Placethefollowing pumpsinPULLSTOP:~EHpumps~Turninggearoilpump~HPsealoilbackuppump3)RestorepowertoMCCs.~AfromBus134BfromBus15~EfromBus15~FfromBus154)WHENbus15restored, THENresetcontrolroomlighting..
5)RefertoAttachment SI/UVforotherequipment lostwithlossofoffsitepower.c.TrytorestoreoffsitepowertoallACbusses(RefertoER-ELEC.1, RESTORATION OFOFFSITEPOWER).
I EOP:ECA-21T!TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE23of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED*****************************************CAUTIONIFRCPSEALCOOLINGHADPREVIOUSLY BEENLOST,THENTHEAFFECTEDRCPSHOULDNOTBESTARTEDPRIORTOASTATUSEVALUATIONS 32CheckRCPStatus-'TLEASTONERUNNINGTrytostartoneRCP:a.Establish conditions forstartinganRCP.oBus11Aor11Benergized IoRefertoAttachment RCPSTART.b.StartoneRCP.IFanRCPcanNOTbestarted,THENverifynaturalcirculation (RefertoAttachment NC).IFnaturalcirculation canNOTbeverified, THENincreasefeedflowordumpingsteam.
ilk EOP:ECA-2~1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE24of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINEDINOTE:AdverseCNMTconditions orlossofforcedaircoolingmayresultinfailureofNISdetectors.
33CheckIfSourceRangeDetectors ShouldBeEnergized:
a.SourcerangechannelsDEENERGIZED a.GotoStep33e.b.Checkintermediate, rangeflux-EITHERCHANNELLESSTHAN1010AMPSb.Performthefollowing:
1)IFneitherintermediate rangechannelisdecreasing THENinitiateboration.
2)ContinuewithStep34.WHENfluxisLESSTHAN10ampsonanyoperablechannel,THENdoSteps33c,dande.c.Checkthefollowing:
oBothintermediate rangechannels-LESSTHAN10-10AMPSc.Continuewithstep34.WHENeithercondition met,THENdoSteps33dande.-OR-oGreaterthan20minutessincereactortripd.Verifysourcerangedetectors ENERGIZED d.Manuallyenergizesource'rangedetectors bydepressing P-6permissive defeatpushbuttons (2of2).e.TransferRk-45recorder'toonesourcerangeandoneintermediate rangechannel.IFsourcerangescanNOTberestored, THENrefertoER-NIS.l, SRMALFUNCTION andgotoStep34.


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE25of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED34CheckIfEmergency D/GsShouldBeStopped:a.VerifyACemergency bussesenergized byoffsitepower:oEmergency D/GoutputbreakersOPENa.Trytorestoreoffsitepower(RefertoER-ELEC.1, RESTORATION OFOFFSITEPOWER).oACemergency busvoltageGREATERTHAN420VOLTSoACemergency busnormalfeedbreakers-CLOSEDb.Stopanyunloadedemergency D/Gandplaceinstandby(RefertoAttachment D/GSTOP)
EOP: ECA-F 1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 27 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 36 Maintain Plant Conditions-STABLE Control plant systems as necessary to maintain conditions stable.o RCS pressure o PRZR level o RCS temperatures
*37 Monitor SI Reinitiation Criteria: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Manually operate SI pumps as necessary.
Return to Step 2.b.PRZR level-GREATER THAN 5%[30%adverse CNMT)b.Control charging flow to maintain PRZR level.IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary.
Return to Step 2~
'I'4 EOP: ECA-F 1 T1TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 28 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 38 Check If SI ACCUMs Should Be Isolated: a.Check the following:
o RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Go to Step 39.o PRZR level-GREATER THAN 5%[30%adverse CNMT]b.Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves~MOV-841, MCC C position 12F~MOV-865, MCC D position 12C c.Close SI ACCUM discharge valves~MOV-841~MOV-865 c.Vent any unisolated ACCUMs: 1)Open vent valves for unisolated SI ACCUMs.d.Locally reopen breakers for MOV-841 and MOV-865~ACCUM A;AOV-834A~ACCUM B, AOV-834B 2)Open HCV-945.  


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE26of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED35Establish NormalShutdownAlignment:
EOP: ECA-2~1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 29 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 39 Check RCS Hot Leg Control feed flow and dump steam to Temperatures
a.Checkcondenser
-LESS THAN 350'F.establish RCS cooldown rate less than 100'F/hr in RCS cold legs.NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.o When using PRZR PORV, select one with operable block valve.40 Check RCS Pressure-LESS THAN 400 PSIG[300 PSIG adverse CNMT]e Use normal PRZR spray.IF normal spray NOT available and letdown is in service, THEN use auxiliary spray.IF NOT, THEN use one PRZR PORV.IF IA NOT available, THEN refer to Attachment N2 PORVS.  
-AVAILABLE a.DispatchAOtoperformAttachment SD-2.b,Performthefollowing:
oOpengenerator disconnects
~1G13A71~9X13A73oPlacevoltageregulator toOFFoOpenturbinedrainvalvesoRotatereheatersteamsupplycontroller camtoclosevalvesoPlacereheaterdumpvalveswitchestoHANDoStopallbutonecondensate pumpc.VerifyadequateRxheadcooling:1)Verifyatleastonecontrolrodshroudfan-RUNNING1)Manuallystartonefanaspowersupplypermits(45kw)2)VerifyoneRxcompartment coolingfan-RUNNING2)Performthefollowing:
oDispatchAOtoresetUVrelaysatMCCCandMCCD.oManuallystartonefanaspowersupplypermits(23kw)d.VerifyAttachment SD-1-COMPLETE


EOP:ECA-F1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE27of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED36MaintainPlantConditions-STABLEControlplantsystemsasnecessary tomaintainconditions stable.oRCSpressureoPRZRleveloRCStemperatures
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 30 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 41 Check If RHR Normal Cooling Can Be Established:
*37MonitorSIReinitiation Criteria:
a.RCS cold leg temperature
a.RCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING a.ManuallyoperateSIpumpsasnecessary.
-LESS THAN 350'F a.Return to Step 37'.RCS pressure-LESS THAN 400 psig[300 psig adverse CNMT]c.Place letdown pressure controller (PCV-135)in MANUAL CLOSED b.Return to Step 40.d.Check following valves-OPEN~AOV-371, letdown isolation valve~AOV-'427, loop B cold leg to REGEN Hx~At least one letdown orifice valve (AOV-200A, AOV-200B, or AOV-202)d.Perform the following:
ReturntoStep2.b.PRZRlevel-GREATERTHAN5%[30%adverseCNMT)b.ControlchargingflowtomaintainPRZRlevel.IFPRZRlevelcanNOTbemaintained, THENmanuallyoperateSIpumpsasnecessary.
1)Reset both trains of XY relays for AOV-371 and AOV-427')Open AOV-371 and AOV-427.3)Open one letdown orifice valve.e.Verify pressure on PI-135-LESS THAN 400 PSIG e.Return to Step 40.f.Place RCS overpressure protection system in service (Refer to 0-7, ALIGNMENT AND OPERATION OF THE REACTOR VESSEL OVERPRESSURE PROTECTION SYSTEM)g.Establish RHR normal cooling (Refer to Attachment RHR COOL)f.IF RCS overpressure protection system can NOT be placed in service, THEN notify TSC of potential Tech Spec violation if RHR system is placed in service.  
ReturntoStep2~  
'I'4 EOP:ECA-F1T1TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE28of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED38CheckIfSIACCUMsShouldBeIsolated:
a.Checkthefollowing:
oRCSsubcooling basedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLING a.GotoStep39.oPRZRlevel-GREATERTHAN5%[30%adverseCNMT]b.DispatchAOwithlockedvalvekeytolocallyclosebreakersforSIACCUMdischarge valves~MOV-841,MCCCposition12F~MOV-865,MCCDposition12Cc.CloseSIACCUMdischarge valves~MOV-841~MOV-865c.Ventanyunisolated ACCUMs:1)Openventvalvesforunisolated SIACCUMs.d.LocallyreopenbreakersforMOV-841andMOV-865~ACCUMA;AOV-834A~ACCUMB,AOV-834B2)OpenHCV-945.  


EOP:ECA-2~1T!TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE29of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED39CheckRCSHotLegControlfeedflowanddumpsteamtoTemperatures
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 31 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 42 Continue RCS Cooldown To Cold Shutdown: a.Maintain cooldown rate in RCS cold legs-LESS THAN 100'F/HR ,b.Check narrow range level in both S/Gs-LESS THAN 50%b.Control feed flow to maintain narrow range level less than 50%'n both S/Gs.43 Check Core Exit T/Cs-LESS THAN 200'F Return to Step 42.44 Evaluate Long Term Plant Status: a.Maintain cold shutdown conditions b.Consult TSC-END-
-LESSTHAN350'F.establish RCScooldownratelessthan100'F/hrinRCScoldlegs.NOTE:oIfauxiliary sprayisinuse,sprayflowmaybeincreased byclosingnormalchargingvalveAOV-294andnormalPRZRsprayvalves.oWhenusingPRZRPORV,selectonewithoperableblockvalve.40CheckRCSPressure-LESSTHAN400PSIG[300PSIGadverseCNMT]eUsenormalPRZRspray.IFnormalsprayNOTavailable andletdownisinservice,THENuseauxiliary spray.IFNOT,THENuseonePRZRPORV.IFIANOTavailable, THENrefertoAttachment N2PORVS.  


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE30of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED41CheckIfRHRNormalCoolingCanBeEstablished:
EOP: TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 ECA-2.1 APPENDIX LIST TITLE 1)RED PATH
a.RCScoldlegtemperature
-LESSTHAN350'Fa.ReturntoStep37'.RCSpressure-LESSTHAN400psig[300psigadverseCNMT]c.Placeletdownpressurecontroller (PCV-135) inMANUALCLOSEDb.ReturntoStep40.d.Checkfollowing valves-OPEN~AOV-371,letdownisolation valve~AOV-'427, loopBcoldlegtoREGENHx~Atleastoneletdownorificevalve(AOV-200A, AOV-200B, orAOV-202)d.Performthefollowing:
1)ResetbothtrainsofXYrelaysforAOV-371andAOV-427')OpenAOV-371andAOV-427.3)Openoneletdownorificevalve.e.VerifypressureonPI-135-LESSTHAN400PSIGe.ReturntoStep40.f.PlaceRCSoverpressure protection systeminservice(Referto0-7,ALIGNMENT ANDOPERATION OFTHEREACTORVESSELOVERPRESSURE PROTECTION SYSTEM)g.Establish RHRnormalcooling(RefertoAttachment RHRCOOL)f.IFRCSoverpressure protection systemcanNOTbeplacedinservice,THENnotifyTSCofpotential TechSpecviolation ifRHRsystemisplacedinservice.


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE31of31STEPACTION/EXPECTED RESPONSERESPONSENOTOBTAINED42ContinueRCSCooldownToColdShutdown:
==SUMMARY==
a.MaintaincooldownrateinRCScoldlegs-LESSTHAN100'F/HR,b.ChecknarrowrangelevelinbothS/Gs-LESSTHAN50%b.Controlfeedflowtomaintainnarrowrangelevellessthan50%'nbothS/Gs.43CheckCoreExitT/Cs-LESSTHAN200'FReturntoStep42.44EvaluateLongTermPlantStatus:a.Maintaincoldshutdownconditions b.ConsultTSC-END-  
2)FIGURE MIN SUBCOOLING 3)ATTACHMENT FAULTED S/G 4)ATTACHMENT CNMT RECIRC FANS 5)ATTACHMENT NC 6)-ATTACHMENT RCP START 7)ATTACHMENT N2 PORVS 8)ATTACHMENT SEAL COOLING 9)ATTACHMENT SI/UV 10)ATTACHMENT D/G STOP 11)ATTACHMENT SD-1 12)ATTACHMENT SD-2 13)ATTACHMENT RHR COOL 14)ATTACHMENT AUX BLDG SW 15)FOLDOUT PAGES


EOP:TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE1of1ECA-2.1APPENDIXLISTTITLE1)REDPATHSUMMARY2)FIGUREMINSUBCOOLING 3)ATTACHMENT FAULTEDS/G4)ATTACHMENT CNMTRECIRCFANS5)ATTACHMENT NC6)-ATTACHMENT RCPSTART7)ATTACHMENT N2PORVS8)ATTACHMENT SEALCOOLING9)ATTACHMENT SI/UV10)ATTACHMENT D/GSTOP11)ATTACHMENT SD-112)ATTACHMENT SD-213)ATTACHMENT RHRCOOL14)ATTACHMENT AUXBLDGSW15)FOLDOUTPAGES
EOP: ECA-2.1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 RED PATH


EOP:ECA-2.1T!TLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE1of1REDPATHSUMMARYa.SUBCRITICALITY
==SUMMARY==
-Nuclearpowergreaterthan54b.CORECOOLING-CoreexitT/Csgreaterthan1200'F-OR-CoreexitT/Csgreaterthan700'FANDRVLISlevel(noRCPs)lessthan43%[464adverseCNMT]c.HEATSINK-NarrowrangelevelinallS/Gslessthan54[254adverseCNMT]ANDtotalfeedwater flowlessthan200gpmd.INTEGRITY
a.SUBCRITICALITY
-Cold.legtemperatures decreasegreaterthan100'F'inlast60minutesANDRCScoldlegtemperature lessthan285'Fe.CONTAINMENT
-Nuclear power greater than 54 b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than 43%[464 adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[254 adverse CNMT]AND total feedwater flow less than 200 gpm d.INTEGRITY-Cold.leg temperatures decrease greater than 100'F'in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT
-CNMTpressure.
-CNMT pressure.greater than,60 psig
greaterthan,60psig


EOP:ECA-2.1TITLE:UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE1of1FIGUREMINSUBCOOLING NOTE:Subcooling Margin=Saturation Temperature FromFigureBelow[-]CoreExitT/CIndication SPRESSURE(PSIG)RC2500240023002200210020001900'80017001600150014001300120011001000900800700600500400300200100020RCSPRESSUREINCREHENTS 20PSIGSUBCOOLED REGIONINADEQUATE SUBCOOLING REGIONADVERSECNHTTEHPERATURE INCREHENTS 10'FNORHALCNHT0'50300350400450500550600650700COREEXITSATURATION TEHPERATURE
EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below[-]Core Exit T/C Indication S PRESSURE (PSIG)RC 2500 2400 2300 2200 2100 2000 1900'800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 20 RCS PRESSURE INCREHENTS 20 PSIG SUBCOOLED REGION INADEQUATE SUBCOOLING REGION ADVERSE CNHT TEHPERATURE INCREHENTS 10'F NORHAL CNHT 0'50 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEHPERATURE
('F)  
('F)  


EOP!ECA-2.1TITLE!UNCONTROLLED DEPRESSURIZATION OFBOTHSTEAMGENERATORS REV:12PAGE1of1FOLDOUTPAGE1.SIREINITIATION CRITERIAManuallyoperateSIpumpsasnecessary ifEITHERcondition listedbelowoccurs:oRCSsubcooling basedoncoreexitTCs-LESSTHANO'FUSINGREQUIREMENTS OFFIGUREMINSUBCOOLING oPRZRlevel-CHARGINGCANNOTCONTROLLEVELGREATERTHAN54[304ADVERSECNMT]2.E-2TRANSITION CRITERIAIFanyS/Gpressureincreases atanytime(exceptwhileperforming SItermination inSteps18and19),THENgotoE-2,FAULTEDSTEAMGENERATOR ISOLATION, Step1.3.COLDLEGRECIRCULATION SWITCHOVER CRITERION IFRWSTleveldecreases tolessthan284,THENgotoES-1.3,TRANSFERTOCOLDLEGRECIRCULATION, Step1.4.LOSSOFEMERGENCY COOLANTRECIRCULATION CRITERION IFemergency coolantrecirculation isestablished andsubsequently lost,THENgotoECA-1.1,LOSSOFEMERGENCY COOLANTRECIRCULATION,
EOP!ECA-2.1 TITLE!UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 FOLDOUT PAGE 1.SI REINITIATION CRITERIA Manually operate SI pumps as necessary if EITHER condition listed below occurs: o RCS subcooling based on core exit TCs-LESS THAN O'F USING REQUIREMENTS OF FIGURE MIN SUBCOOLING o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 54[304 ADVERSE CNMT]2.E-2 TRANSITION CRITERIA IF any S/G pressure increases at any time (except while performing SI termination in Steps 18 and 19), THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step 1.3.COLD LEG RECIRCULATION SWITCHOVER CRITERION IF RWST level decreases to less than 284, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step 1.4.LOSS OF EMERGENCY COOLANT RECIRCULATION CRITERION IF emergency coolant recirculation is established and subsequently lost, THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION,'Step 1.5.AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.l, ALTERNATE WATER SUPPLY TO AFW PUMPS).}}
'Step1.5.AFWSUPPLYSWITCHOVER CRITERION IFCSTleveldecreases tolessthan5feet,THENswitchtoalternate AFWwatersupply(RefertoER-AFW.l, ALTERNATE WATERSUPPLYTOAFWPUMPS).}}

Revision as of 14:10, 7 July 2018

Rev 11 to EOP E-1, Loss of Reactor or Secondary Coolant.
ML17263A197
Person / Time
Site: Ginna Constellation icon.png
Issue date: 03/24/1993
From: MARLOW T A
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17263A191 List:
References
E-1, NUDOCS 9304080163
Download: ML17263A197 (194)


Text

EOP: E-1 TITLE: LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 1 of 16 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE l v>>PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY: ,9304080163 930330"." PDRADOCK 05000244 P..""'PDR 1 P g'f EOP: E-1 TLTLE: LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 2 of 16 A.PURPOSE-This procedure provides actions to recover from a loss of reactor or secondary coolant.B.ENTRY CONDITIONS/SYMPTOMS l.ENTRY CONDITIONS

-This procedure is entered from: a.E-O, REACTOR TRIP OR SAFETY INJECTION, and FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, when a PRZR PORV is stuck open and its block valve can not be closed.b.E-O, REACTOR TRIP OR SAFETY INJECTION, with any of the following symptoms: high containment radiation, high containment pressure, or high containment recirculation sump level.c~E 0 g REACTOR TRI P OR SAFETY I N JECTION g ECA 2 1 g UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS, and FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, when RCS pressure is less than the shutoff head pressure of the RHR pumps or is decreasing.

d.ES-1.1, SI TERMINATION, and FR-I.2, RESPONSE TO LOW PRESSURIZER LEVEL, if SI has to be reinitiated.

e.E-2, FAULTED STEAM GENERATOR ISOLATION, after identification and isolation of a faulted S/G.f ECA 0~2 g LOSS OF ALL AC POWER RECOVERY WITH S I REQUIRED I after normal injection mode conditions are established.

g.ECA-1.2, LOCA OUTSIDE CONTAINMENT, when a LOCA outside containment is isolated.h.FR-C.1, RESPONSE TO INADEQUATE CORE COOLING, and FR-C.2, RESPONSE TO DEGRADED CORE COOLING, after core cooling has been r established.

i.FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, if RCS pressure is less than all non-faulted S/G(s)pressure.j.FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, after secondary heat sink has been reestablished and all PRZR PORVs are close.

EOP: E-1 TITLE: 'LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 3 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF RWST LEVEL DECREASES TO LESS THAN 28%, THEN THE SI SYSTEM SHOULD BE ALIGNED FOR COLD LEG RECIRCULATION USING ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, STEP 1.NOTE'FOLDOUT page should be open AND monitored periodically.

o Critical Safety Function Status Trees should be monitored.(Refer to Appendix 1 for Red Path Summary.), o Conditions should be evaluated for Site Contingency Reporting (Refer to EPIP-1.0, GINNA STATION EVENT EVALUATION AND CLASSIFICATION)., o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+R/hr.*1 Monitor RCP Trip Criteria: a.RCP status-ANY RCP RUNNING b.SI pumps-AT LEAST TWO RUNNING c.RCS pressure minus maximum S/G pressure-LESS THAN 175 psig[400 psig adverse CNMT]d.Stop both RCPs a.Go to Step 2.b, Go to Step 2.c.Go to Step 2.

EOP I E-1 TITLE: LOSS OF REACTOR OR SECONDARY COOLANT REV: ll PAGE 4 of 16 STEP ACTION/EXPECTED RESPONSE~RESPONSE NOT OBTAINED 2 Check If S/G Secondary Side Is Intact: o Pressure in both S/Gs-STABLE OR INCREASING IF any S/G pressure decreasing in an uncontrolled manner OR completely depressurized, THEN verify faulted S/G isolated unless needed for RCS cooldown: o Pressure in both S/Gs-GREATER THAN 100 PSIG~Steamlines

~Feedlines IF NOT, THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step l.*****************************************CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).NOTE: TDAFW pump flow control valves fail open on loss of IA.*3 Monitor Intact S/G Levels: a.Narrow range level-GREATER THAN 58[258 adverse CNMT]b.Control feed flow to maintain narrow range level between 178[258 adverse CNMT]and 508 a.Maintain total feed flow greater than 200 gpm until narrow range level greater than 58[258 adverse CNMT]in at least one S/G.b.IF narrow range level in any S/G continues to increase in an uncontrolled manner, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.

W 1 N EOP!E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 5 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Check Secondary Radiation Levels-NORMAL o Steamline radiation monitor (R-31 and R-32)o Request HP sample S/Gs for activity IF steamline radiation monitors NOT available, THEN dispatch AO to locally check steamline radiation.

IF abnormal radiation levels detected in any S/G, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.*****************************************CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 5B).*5 Monitor PRZR PORV Status: a.Power to PORV block valves-AVAILABLE b.PORVs-CLOSED a.Restore power to block valves unless block valve was closed to isolate an open PORV:~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C b.IF PRZR pressure less than 2335 psig, THEN manually close PORVs.c.Block valves-AT LEAST ONE OPEN IF any PORV can NOT be closed, THEN manually close its block valve.IF block valve can NOT be closed, THEN dispatch AO to locally check breaker.~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C c.Open one block valve unless it was closed to isolate an open PORV.

K EOP!E-1 TITLE LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 6 of 16 ,STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

6 Reset SZ 7 Reset CI: a.Depress CI reset pushbutton b., Verify annunciator A-26, CNMT ISOLATION-EXTINGUISHED b.Perform the following:

1)Reset SI.2)Depress CI reset pushbutton.

8.Verify Adequate SW Flow: a.Check at least two SW pumps RUNNING b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN perform the following:

1)Ensure SW isolation.

2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)3)Go to Step 10.

EOP I E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 7 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 9 Establish IA to CNMT: a.Verify non-safeguards busses energized from offsite power o Bus 13 normal feed-CLOSED-OR-o Bus 15 normal feed-CLOSED b, Verify turbine building SW isolation valves-OPEN~MOV-4613 and MOV-4670~MOV-4614 and MOV-4664 c.Verify at least two air compressors

-RUNNING d.Check IA supply: o Pressure-GREATER THAN 60 PSIG o Pressure-STABLE OR INCREASING e.Reset both trains of XY relays for IA to CNMT AOV-5392 f.Verify IA to CNMT AOV-5392-OPEN a.Perform the following:

1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie'Bus 15 to Bus 16 tie 2)Verify adequate emergency D/G capacity to run air compressors (75 kw each).IF NOT, THEN evaluate if CNMT'ECIRC fans should be stopped (Refer to Attachment CNMT RECIRC FANS).3)WHEN bus 15 restored, THEN reset control room lighting.b.Manually align valves.c.Manually start air compressors as power supply permits (75 kw each).IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.

d.Perform the following:

1)Continue attempts to restore IA (Refer to AP-IA.1, LOSS OF INSTRUMENT AIR).2)Continue with Step 10.WHEN IA restored, THEN do Steps 9e and f.

f)

E-l.LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 8 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 10 Check Normal Power Available To Charging Pumps: o Bus 14 normal feed breaker-'CLOSED o Bus 16 normal feed breaker-CLOSED Verify adequate emergency D/G capacity to run charging pumps (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans can be stopped (Refer to Attachment CNMT RECIRC FANS)..

EOP: E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 9 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED ll Check If Charging Flow Has Been Established:

a.Charging pumps-ANY RUNNING a.Perform the following:

1)IF CCW flow is lost to any.RCP thermal barrier OR any RCP¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal in)ection needle valve(s)to affected RCP:~V-300A for RCP A~V-300B for RCP B b.Charging pump suction aligned to RWST'LCV-112B-OPEN o LCV-112C-CLOSED 2)Ensure HCV-142 open, demand at 0%.b.Manually align valves as necessary.

IF LCV-112B can NOT be opened, THEN perform the following:

1)Verify charging pump A NOT running and place in PULL STOP.c.Start charging pumps as necessary and adjust charging flow to restore PRZR level 2)Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).3)WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).

lp',~

EOP: E-1 T1TLE: LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 10 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 12 Check If SI Should Be Terminated:

a.RCS pressure: o Pressure-GREATER THAN 1625 psig[1825 psig adverse CNMT]o Pressure-STABLE OR INCREASING a.Do NOT stop SI pumps.Go to Step 14.b.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING b.Do NOT stop SI pumps.Go to Step 14.c.Secondary heat sink: o Total feed flow to intact S/Gs-GREATER THAN 200 GPM-OR-c.IF neither condition satisfied, THEN do NOT stop SI pumps.Go to Step 14.o Narrow range level in at least one intact S/G-GREATER THAN 5%[25%adverse CNMT]d.PRZR level-GREATER THAN 5%[30%adverse CNMT]d;Do NOT stop SI pumps'erform the following:

1)IF normal PRZR spray available, THEN try to stabilize RCS pressure with PRZR spray.2)Go to Step 14.

EOP s E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV: ll PAGE 11 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Go To ES-1.1, SI TERMINATION/

Step 1*14 Monitor If CNMT Spray Should Be Stopped: a.CNMT spray pumps-RUNNING b.Check the following:

o CNMT pressure-LESS THAN 4 PSIG a.Go to Step 15.b.Continue with Step 15.WHEN BOTH conditions satisfied, THEN do'Steps 14c through f.o Sodium hydroxide tank level-LESS THAN 55%c.Reset CNMT spray d.Check NaOH tank outlet valves-CLOSED~AOV-836A~AOV-836B d;Place NaOH tank outlet valve controllers to MANUAL and close valves.e.Stop CNMT spray pumps and place in AUTO f.Close CNMT spray pump discharge valves~MOV-860A~MOV-860B~MOV-860C~MOV~860D C

EOP: E-1 TITLE.LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 12 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************, CAUTION o IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

o RCS PRESSURE SHOULD BE MONITORED.

IF RCS PRESSURE DECREASES TO LESS THAN 250 PSIG[465 PSIG ADVERSE CNMT], THEN THE RHR PUMPS MUST BE MANUALLY RESTARTED TO SUPPLY WATER TO THE RCS.*15 Monitor If RHR Pumps Should.Be Stopped: a.Check RCS pressure: 1)Pressure-GREATER THAN 250 psig[465 psig adverse CNMT]2)RCS pressure-STABLE OR~INCREASING b.Stop RHR pumps and place in AUTO 1)Go to Step 17.2)Go to Step 16.16 Check RCS And S/G Pressures a.Check pressures in both S/Gs STABLE OR INCREASING a.Return to Step 1.b.Check pressures in both S/Gs-GREATER THAN 100 PSIG c.Check RCS pressure-STABLE OR DECREASING b.Monitor RCS pressure.IF RCS pressure does NOT increase after faulted S/G dryout, THEN go to Step 17.c.Return to Step l.

EOP: E-1 TLTLE: LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 13 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN o AC emergency bus voltage GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED a.Perform the following:

1)Close non-safeguards bus tie breakers as necessary:

~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Place the following pumps in PULL STOP'EH pumps~Turning gear oil pump~HP seal oil backup pump 3)Ensure condenser steam dump mode control in MANUAL.4)Restore power to MCCs:~A from Bus 13~B from Bus 15~E from Bus 15'F from Bus 15 5)WHEN bus 15 restored, THEN reset control room lighting breaker.6)Refer to Attachment SI/UV for other equipment lost with loss of offsite power.7)Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).b.Stop any unloaded emergency D/G~and place in standby (Refer to Attachment D/G STOP)

EOP E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV'1 PAGE 14 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Verify CNMT Sump Recirculation Capability:

a.Check RHR system: 1)Power available to emergency AC busses and MCCs required for CNMT sump recirculation o Bus 14 and bus 18 ENERGIZED a.Restore'power to at least one train of emergency AC busses.IF at least one train of cold leg recirculation capability can NOT be verified, THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step 1.o MCC C-ENERGIZED o Bus 16 and bus 17-ENERGIZED o MCC D-ENERGIZED 2)RHR pumps and valves OPERABLE b.Check SW pumps-AT LEAST 2 PUMPS AVAILABLE c.Dispatch AO to check AUX BLDG sub-basement for RHR system leakage (AUX BLDG sub-basement key may'be required)b.Attempt to restore at least 2 SW pumps to operable.IF only 1 SW pump available, THEN refer to Attachment MIN SW for additional guidance.c.IF any RHR pump seal leakage indicated, THEN leakage should.be evaluated and isolated if necessary.

II E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 15 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 19 Evaluate Plant Status: a.Check auxiliary building radiation-NORMAL~Plant vent iodine (R-10B)~Plant vent particulate (R-13)~Plant vent gas (R-14)~CCW liquid monitor (R-17)~LTDN line monitor (R-9)~CHG pump room (R-4)b.Direct HP to obtain following samples:~RCS boron~RCS activity~CNMT hydrogen~CNMT sump boron~BASTs,boron a.Notify HP and refer to appropriate AR-RMS procedure.

IF the cause is a loss of RCS inventory outside CNMT, THEN go to.ECA-1.2, LOCA OUTSIDE CONTAINMENT, Step 1.c.Verify adequate Rx head cooling: 1)Check IA to CNMT-AVAILABLE 2)Verify at least one control rod shroud fan-RUNNING 3)Verify, one Rx compartment cooling fan-RUNNING 1)Go to Step 20.2)Manually start one fan as power supply permits (45 kw)3)Perform the following:

o Dispatch AO to reset UV relays at MCC C and MCC D o Manually start one fan as power supply permits'(23 kw)

EOP: E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 16 of 16 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 20 Check If RCS Cooldown And Depressurization Is Required: a.RCS pressure-GREATER THAN 250 psig[465 psig adverse CNMT]b.Go to ES-1.2, POST LOCA COOLDOWN AND DEPRESSURIZATION, Step 1 a.IF RHR pump flow greater than 475 gpm, THEN go to Step 21, 21 Check If Transfer To Cold Leg Recirculation Is Required: a.RWST level-LESS THAN 28%b.Go to ES-1;3, TRANSFER TO COLD LEG RECIRCULATION, Step 1 a.Return to Step 18.-END-I EOP: LOSS OF REACTOR OR SECONDARY COOLANT REV: 11 PAGE 1 of 1 E-1 APPENDIX LIST TITIZ PAGES 1)RED PATH

SUMMARY

2)FIGURE MIN SUBCOOLING 3)ATTACHMENT CNMT RECIRC 4)ATTACHMENT D/G STOP 5)ATTACHMENT SD-1 6)ATTACHMENT SI/UV 7)ATTACHMENT MIN SW 8)ATTACHMENT AUX BLDG SW 9)ATTACHMENT SW LOADS IN CNMT 10)FOLDOUT

EOP s E-1 T1TLE0 LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 1 of 1 RED PATH

SUMMARY

a.SUBCRITICALITY

-Nuclear power greater than 54 b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than'34[464 adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[254 adverse CNMT]AND total feedwater flow less than 200 gpm d.INTEGRITY-Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT

-CNMT pressure greater than 60 psig

EOP.E-1 TITLE: LOSS OF REACTOR OR SECONDARY COOLANT REV ll PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below[-]Core Exit T/C Indication RC 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 S PRESSURE (PSIG)RCS PRESSURE INCREMENTS 20 PSIG SUBCOOLED REGION ADVE E CNMT RS NORMAL CNMT INADEQUATE SUBCOOLING REGION TEMPERATURE INCREMENTS 10'200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEMPERATURE

('F)

EOP: E-1 LOSS OF REACTOR OR SECONDARY COOLANT REV 11 PAGE 1 of 1 FOLDOUT PAGE 1.SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN manually operate SI pumps as necessary:

o RCS subcooling based on core exit T/Cs-LESS THAN O'F USING FIGURE MIN SUBCOOLING OR-o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%[30%adverse CNMT]2~SI TERMINATION CRITERIA IF ALL conditions listed below occur, THEN go to ES-1.1, SI TERMINATION, Step 1: a.RCS subcooling based on core exit T/Cs-GREATER THAN 0 F USING FIGURE MIN SUBCOOLING b.Total feed flow to intact S/Gs-GREATER THAN 200 GPM OR-Narrow range level in at least one intact S/G-GREATER THAN 5%[25%adverse CNMT]c.RCS pressure: o GREATER THAN 1625 PSIG[1825 psig adverse CNMT]o STABLE OR INCREASING d.PRZR level-GREATER THAN 5%[30%adverse CNMT]3.SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2, FAULTED S/G ISOLATION, Step 1.4.COLD LEG RECIRCULATION SWITCHOVER CRITERION IF RWST level decreases to less than 28%, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step.l.5.AFW SUPPLY SWITCHOVER CRITERION IF CST'evel decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.l, ALTERNATE WATER SUPPLY TO AFW PUMPS).6.E-3 TRANSITION CRITERIA IF any S/G'level increases in an uncontrolled manner or any S/G has abnormal radiation, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.

EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 1 of 38 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW 1 PORC REVIEW DATE k'LANT SUPERINTENDENT EFFECTIV DATE CATEGORY 1.0 REVIEWED BY:

0 f IC K c A aJ pP,*t EOP: E-3 JITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 2 of 38 A.PURPOSE-This procedure provides actions to terminate leakage of reactor coolant into the secondary system following a steam generator tube rupture (SGTR), this procedure should also be used for a SGTR in one S/G and a fault in the other S/G.B.ENTRY CONDITIONS/SYMPTOMS l.ENTRY CONDITIONS

-This procedure is entered from: a.E-O, REACTOR TRIP OR SAFETY INJECTION, when condenser air ejector radiation or blowdown radiation is abnormal, or b~E 0 g REACTOR TRIP OR SAFETY INJECTION/

E 1/LOSS OF REACTOR OR SECONDARY COOLANT g E-2, FAULTED STEAM GENERATOR ISOLATION, and FR HE 3 RESPONSE TO STEAM GENERATOR HIGH LEVELS when secondary radiation is abnormal, or c.E-O, REACTOR TRIP OR SAFETY INJECTION/

E 1 g LOSS OF REACTOR OR SECONDARY COOLANT g ES 1~2 g POST LOCA COOLDOWN AND DEPRESSURI ZATION g ECA 3~3 g SGTR WITHOUT PRESSURI ZER PRESSURE CONTROLS when an intact S/G narrow range level increases in an uncontrolled manner.d ECA 3~3~SGTR WITHOUT PRESSURI ZER PRESSURE CONTROL/when pressurizer pressure control is restored.e.E-1 series FOLDOUT page'whenever either S/G level increases in an uncontrolled manner or either S/G has abnormal radiation.

~A$r a.a EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 3 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o FOLDOUT page should be open AND monitored periodically.

o Critical Safety Function Status Trees should be monitored (Refer to Appendix 1 for Red Path Summary).o Personnel should be available for sampling during this procedure.

o Conditions should be evaluated for Site Contingency Reporting (EPIP-1.0, GINNA STATION EVENT EVALUATION AND CLASSIFICATION).

o Adverse CNMT values should be used whenever CNMT pressure is , greater than 4 psig or CNMT radiation is greater than 10+R/hr.*1 Monitor RCP Trip Criteria: a.RCP status-ANY RCP RUNNING b.SI pumps-AT LEAST TWO RUNNING c.RCS pressure minus maximum S/G pressure--LESS THAN 175 psig (400 psig adverse CNMTj d.Stop both RCPs a.Go to Step 2.b.Go to Step 2.c.Go to Step 2.

\

EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 4 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 2 Identify Ruptured S/G(s): o Unexpected increase in either S/G narrow range level-OR-Continue with Steps 6 through 11.WHEN ruptured S/G(s)identified, THEN do Steps 3, 4 and 5.o High radiation indication on main steamline radiation monitor~R-31 for S/G A~R-32 for S/G B-OR-o AO reports local indication of high steamline radiation-OR-o RP reports high radiation from S/G activity sample 4 WJ EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 5 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED************

x****x*%*********************

CAUTION o IF THE TDAFW PUMP.IS THE ONLY AVAILABLE SOURCE OF FEED FLOW, STEAM SUPPLY TO THE TDAFW PUMP MUST BE MAINTAINED FROM ONE S/G.o AT LEAST ONE S/G SHALL BE MAINTAINED AVAILABLE FOR RCS COOLDOWN.3 Isolate Flow From Ruptured S/G (s): a.Adjust ruptured S/G ARV controller to'050 psig in AUTO b.Check ruptured S/G ARV-CLOSED b.WHEN ruptured S/G pressure less than 1050 psig, THEN verify S/G ARV closed.IF NOT closed, THEN place controller in MANUAL and close S/G ARV.IF S/G ARV can NOT be closed, THEN dispatch AO to*locally isolate.c.Close ruptured S/G TDAFW pump steam supply valve and place in PULL STOP~S/G A, MOV-3505A~S/G B, MOV-3504A c.IF at least one MDAFW pump running, THEN dispatch AO with locked valve key to locally isolate steam from ruptured S/G to TDAFW pump.~S/G A, V-3505~S/G B, V-3504 d.Verify ruptured S/G blowdown valve-CLOSED d.Place S/G blowdown and sample valve isolation switch to CLOSE.~S/G A, AOV-5738~S/G B, AOV-5737 IF blowdown can NOT be isolated manually, THEN dispatch AO to locally isolate blowdown..

~S/G A, V-5701~S/G B, V-5702 a1 Ill I't il U EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 6 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Complete Ruptured S/G Isolation:

a.Close ruptured S/G MSIV-RUPTURED S/G MSIV CLOSED a.Perform the following:

1)Close intact S/G MSIV.2)Place intact S/G ARV controller at 1005 psig in AUTO.3)Place condenser steam dump mode selector switch to MANUAL.4)Adjust condenser steam dump controller to 1050 psig in AUTO.5)Adjust reheat steam supply controller cam to close reheat steam supply valves.6)Ensure turbine stop valves CLOSED.7)Dispatch AO to complete ruptured S/G isolation (Refer to Attachment RUPTURED S/G, parts A and B).b.Dispatch AO to complete ruptured S/G isolation (Refer to Attachment RUPTURED S/G part A)IF the ruptured S/G can NOT be isolated from the intact S/G, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT SUBCOOLED RECOVERY DESIRED, Step 1 L~Qt J>;

EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 7 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**********

x*a***x x x x%*x x*****************

CAUTION IF ANY RUPTURED S/G IS FAULTED, FEED FLOW TO THAT S/G SHOULD REMAIN ISOLATED DURING SUBSEQUENT RECOVERY ACTIONS UNLESS NEEDED FOR RCS COOLDOWN.5 Check Ruptured S/G Level: a.Narrow range level-GREATER THAN 5%[25%adverse CNMT)a.IF ruptured S/G NOT faulted, THEN perform the following:

l)Maintain feed flow to ruptured S/G until level greater than 5%[25%adverse CNMT).2)Continue with Step 6.WHEN ruptured S/G level greater than 5%[25%adverse CNMT], THEN do Steps 5b through e.b.Close MDAFW pump discharge valv'e to ruptured S/G b.Dispatch AO to locally close valve.~S/G A, MOV-4007~S/G B, MOV-4008 c.Pull stop MDAFW pump for ruptured S/G d.Close TDAFW pump flow control valve to ruptured S/G~S/G A, AOV-4297~S/G B, AOV-4298 e.Verify MDAFW pump crosstie valves-CLOSED d.Dispatch AO with locked valve key to locally close TDAFW pump manual feedwater isolation valve to ruptured S/G.~S/G A, V-4005~S/G B, V-4006 e.Manually close valves.~MOV-4000A~MOV-4000B U~W~p*~ga t, r.g'1 EOP: E-3 ijiLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 8 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**********

x*****x**%*********************

CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 6B).**************

P***x 0 x*0***x**************

  • 6 Monitor PRZR PORVs And Block Valves: a.Power to PORV block valves AVAILABLE a.Restore power to block valves unless block valve was closed to isolate an open PORV: b.PORVs-CLOSED~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C b.IF PRZR pressure less than 2335 psig, THEN manually close PORVs.c.Block valves-AT LEAST ONE OPEN IF any PORV can NOT be closed, THEN manually close its block valve.IF block valve can NOT be closed, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.c.Open one block valve unless it was closed to isolate an open PORV.

P'>fg EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 9 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Check If S/G Secondary Side Is Intact: o Pressure in both S/Gs-STABLE OR INCREASING IF any S/G pressure decreasing in an uncontrolled manner OR completely depressurized, THEN verify faulted S/G isolated unless needed for RCS cooldown: o Pressure in both S/Gs-GREATER THAN 100 PSIG~Steamlines

~Feedlines IF faulted S/G NOT isolated, THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step 1.**********

x%**x%x x x x**x******************

CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).*******x*4*%x*x**x**%********************

NOTE: TDAFW pump flow control valves fail open on loss of IA.*8 Monitor Intact S/G Level: a.Narrow range level-GREATER THAN 5%[25%adverse CNMT)b.Control feed flow to maintain narrow range level between 17%[25%adverse CNMT)and 50%a.Maintain total feed flow greater than 200 gpm until narrow range level greater than 5%[25%adverse CNMT)in at least one S/G.b.IF narrow range level in, the intact S/G continues to increase in an uncontrolled manner, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step l.

%tk Cg gt EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 10 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED********x*x~*%x'.*x x*a*x x**x x***x*********CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN, SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

x x x**x x*x***x******************

9 Reset SI 10 Reset CI: a.Depress CI reset pushbutton b.Verify annunciator A-26, CNMT ISOLATION-EXTINGUISHED b.Perform the following:

1)Reset SI.2)Depress CI reset pushbutton.

x x**x x x********************

CAUTION RCS PRESSURE SHOULD BE MONITORED.

IF RCS PRESSURE DECREASES TO LESS THAN 250 PSIG[465 PSIG ADVERSE CNMT), THEN THE RHR PUMPS MUST BE MANUALLY RESTARTED TO SUPPLY WATER TO THE RCS.**********%

          • x x**x********************

11 Check If RHR Pumps Should Be Stopped: a.Check RCS pressure: a.Go to Step 12.o Pressure-GREATER THAN 250 psig[465 psig adverse CNMTj o Pressure-STABLE OR INCREASING b.Stop RHR pumps and place both in AUTO fA~m f+J g~'k EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 11 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: If ruptured S/G needed for cooldown, isolation is not necessary.

12 Verify Ruptured S/G Isolated: a.Check ruptured MSIV-CLOSED b.Ruptured S/G pressure-GREATER THAN 300 PSIG a.IF only intact S/G MSIV can be closed, THEN ensure air ejector/gland steam supply and flange heating steam isolated.(Refer to ATTACHMENT RUPTURED S/G, part B).IF neither S/G MSIV can be closed THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT SUBCOOLED RECOVERY DESIRED, Step 1 b.Go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.13 Establish Condenser Steam Dump Pressure Control: a.Verify condenser available:

o Intact S/G MSIV-OPEN o Annunciator G-15, STEAM DUMP ARMED-LIT a.Adjust S/G ARV controllers to maintain intact S/G pressure in AUTO and go to Step 14.b.Adjust condenser steam dump controller HC-484 to maintain intact S/G pressure and verify in AUTO c.Place steam dump mode selector switch to MANUAL

~s'I~l I c~i~g V W EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 12 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Following initiation of controlled cooldown or depressurization, RCP trip criteria is no longer applicable.

14 Initiate RCS Cooldown: a.Determine required core exit temperature from below table RUPTURED SG PRESSURE 1100 PSIG 1000 PSIG 900 PSIG 800 PSIG 700 PSIG 600 PSIG 500 PSIG 400 PSIG 300 PSIG REQUIRED CORE EXIT TEMPERATURE

('F)525[505 adverse CNMT)510[490 adverse CNMT)500[475 adverse CNMT]485[460 adverse CNMT)465[440 adverse CNMT)450[420 adverse CNMT)425[395 adverse CNMT]405[370 adverse CNMT)375[330 adverse CNMT)b.Initiate dumping steam to condenser from intact S/G at maximum rate b.Manually or locally initiate steam dump from intact S/G at maximum rate using S/G ARV.IF no intact S/G available, THEN perform the following:

o Use faulted S/G.-OR-c.Core exit T/Cs-LESS THAN REQUIRED TEMPERATURE d.Stop RCS cooldown and maintain core exit T/Cs less than required temperature o IF both S/Gs ruptured, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT SUBCOOLED RECOVERY DESIRED, Step 1 c.Continue with Step 15.WHEN core exit T/Cs less than required, THEN do Step 14d.

+k~f EOP: E-3 TtTLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 13 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*15 Monitor All AC Busses-BUSSES ENERGIZED BY OFFSITE POWER o Normal feed breakers to all 480 volt busses-CLOSED o 480 volt bus voltage-GREATER THAN 420 VOLTS o Emergency D/G output breakers OPEN Perform the following:

a.IF any AC emergency bus normal feed breaker open, THEN ensure associated D/G breaker closed.b.Perform the following as necessary:

1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Place the following pumps in PULL STOP:~EH pumps~Turning gear oil pump~HP seal oil backup pump 3)Restore power to MCCs.~A from Bus 13~B from Bus 15~E from Bus 15~F from Bus 15 4)Start CNMT RECIRC fans as necessary.

5)WHEN bus 15 restored, THEN reset control room lighting.c.Try to restore offsite power to all AC busses (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).

pffft'Ill p%~I 4, r l~

EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV'5 PAGE 14 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 16 Verify Adequate SW Flow: a.Check at least two SW pumps RUNNING a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN: 1)Ensure SW isolation.

2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)3)Go to Step 18.

<,1$y 4 4s jf-Qy'"9,, t 4'X;i EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 26 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 30 Verify Adequate SW Flow To CCW Hx: a.Verify at least three SW pumps RUNNING b.Verify AUX BLDG SW isolation valves-AT LEAST ONE SET OPEN~MOV-4615 and MOV-4734~MOV-4616 and MOV-4735 a.Manually start pumps as power supply permits (258 kw each).IF less than two SW pumps can be operated, THEN go to Step 37.b.Establish SW to AUX BLDG (Refer to Attachment AUX BLDG SW).c.Verify CNMT RECIRC fan annunciator C-2, HIGH TEMPERATURE ALARM-EXTINGUISHED c.Dispatch AO to locally throttle flow to CCW Hx to between 5000 gpm and 6000 gpm total flow.

4 I P EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 27 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 31 Check If Normal CVCS Operation Can Be Established a.Verify IA restored: o IA to CNMT (AOV-5392)

-OPEN o IA pressure-GREATER THAN 60 PSIG a.Continue with Step 37.WHEN IA restored, THEN do Steps 31 through 36.b.Verify instrument bus D ENERGIZED c.CCW pumps-ANY RUNNING b.Energize MCC B.IF MCC B NOT available, THEN perform the following:

1)Verify MCC A energized.

2)Place instrument bus D on maintenance supply.c.Perform the following:

1)IF any RCP tl seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected RCP(s).d.Charging pump-ANY RUNNING~RCP A, MOV-749A and MOV-759A~RCP B, MOV-749B and MOV-759B 2)Manually start one CCW pump.d.Continue with Step 37.WHEN any charging pump running, THEN do Steps 32 through 36.

I'1'r I V I IWg EOP: E-3 JIZLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 28 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 32 Check If Seal Return Flow Should Be Established:

a.Verify RCP¹1 seal outlet temperature

-LESS THAN 235'F b.Verify RCP seal outlet valves OPEN~AOV-270A~AOV-270B a.Go to Step 33.b.Manually open valves as necessary.

c.Reset both trains of XY relays for RCP seal return isolation valve MOV-313 d.Open RCP seal return isolation valve MOV-313 d.Perform the following:

1)Place MOV-313 switch to OPEN.e.Verify RCP¹1 seal leakoff flow LESS THAN 5.5 GPM 2)Dispatch AO with key to RWST gate to locally open MOV-313.e.IF any RCP seal leakoff flow greater than 5.5 gpm, THEN: o Close the affected RCP seal discharge valve~RCP A, AOV-270A~RCP B, AOV-270B f.Verify RCP¹1 seal leakoff flow GREATER THAN 0.25 GPM o Trip the affected RCP IF both RCP seal discharge valves are shut, THEN go to Step 33.f.Refer to AP-RCP.1, RCP SEAL MALFUNCTION.

I.'~I~.4 Al tg~Ck EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 29 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 33 Verify PRZR Level-GREATER THAN 13%[40: adverse CNMT]Continue with Step 35.WHEN PRZR level increases to greater than 13%[40%adverse CNMT], THEN do Step 34.34 Establish Normal Letdown: a.Establish charging line flow to REGEN Hx-GREATER THAN 20 GPM b.Place the following switches to CLOSE:~Letdown orifice valves (AOV-200A, AOV-200B, and AOV-202)~Letdown isolation valve AOV-371~Loop B cold leg to REGEN Hx AOV-427 c.Place letdown controllers in MANUAL at 40%open~TCV-130~PCV-135 d.Reset both trains of XY relays for AOV-371 and AOV-427 e.Open AOV-371 and AOV-427 IF RCP seal return has been established, THEN establish excess letdown as follows: o Place excess letdown divert valve, AOV-312, to NORMAL.o Ensure CCW from excess letdown open, (AOV-745).

o Open excess letdown isolation valve AOV-310.o Slowly open HCV-123 to maintain excess letdown temperature less than 195'F and pressure less than 100 psig.o Adjust charging pump speed as necessary.

IF RCP seal return NOT established, THEN consult TSC to determine if excess letdown should be placed in service.f.Open letdown orifice valves as necessary g.Place TCV-130 in AUTO at 105'F h.Place PCV-135 in AUTO at 250 psig i.Adjust charging pump speed and HCV-142 as necessary A h EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 30 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 35 Check VCT Makeup System: a.Adjust boric acid flow control valve in AUTO to 9.5 gpm b.Verify the following:

1)RMW mode selector switch in AUTO b.Adjust controls as necessary.

2)RMW control armed-RED LIGHT LIT c.Check VCT level: o Level-GREATER THAN 20%-OR-o Level-STABLE OR INCREASING c.Manually increase VCT makeup flow as follows: 1)Ensure BA transfer pumps and RMW pumps running.IF NOT, THEN reset MCC C and MCC D UV~lockouts as necessary.

2)Place RMW flow control valve HCV-111 in MANUAL and increase RMW flow.3)Increase boric acid flow as necessary.

I>~M t~, M.lt Cg~a~4~I P h~4 EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 31 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 36 Check Charging Pump Suction Aligned To VCT: a.VCT level-GREATER THAN 20%a.IF VCT level can NOT be maintained greater than 5%, THEN perform the following:

1)Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed 2)Continue with Step 37.WHEN VCT level greater than 40%, THEN do Step 36b.b.Verify charging pumps aligned to VCT o LCV-112C-OPEN o LCV-112B-CLOSED b.Manually align valves as necessary.

Pp<<4.ig%1EP EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 32 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**************

x**x*x x x*******************

CAUTION RCS AND RUPTURED S/G PRESSURES MUST BE MAINTAINED LESS THAN 1050 PSIG.***xx*******xxxxxxx*xx*x*xx****x*********

  • 37 Control RCS Pressure And Makeup Flow To Minimize RCS-To-Secondary Leakage: a.Perform appropriate action(s)from table: PRZR LEVEL RUPTURED S/G NARROW RANGE LEVEL INCREASING DECREASING OFFSCALE HIGH LESS THAN 13%[40%ADVERSE CNMTJ BETWEEN 13%[40%ADVERSE CNMT)AND 50%BETWEEN 50%AND 75%[65%ADVERSE CNMTj GREATER THAN 75%[65%ADVERSE CNMT]o Increase RCS makeup flow o Depressurize RCS using Step 37b Depressurize RCS using Step 37b o Depressurize RCS using Step 37b o Decrease RCS makeup flow o Decrease RCS makeup flow Increase RCS makeup flow Energize PRZR heaters Energize PRZR heaters Energize PRZR heaters o Increase RCS makeup flow o Maintain RCS and ruptured S/G pressure equal Maintain RCS and ruptured S/G pressure equal Maintain RCS and ruptured S/G pressure equal Maintain RCS and ruptured S/G pressure equal b.Control pressure using normal PRZR spray, if available, to obtain desired results for Step 37a b.IF letdown is in service, THEN use auxiliary spray (AOV-296).

IF NOT, THEN use one PRZR PORV.

I')~4 N 1g'0'1I+S EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 33 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 38 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN a.Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).o AC emergency bus voltage GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED b.Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP).39 Minimize Secondary System Contamination:

a.Isolate reject from hotwell to CST: o Place hotwell level controller (LC-107)in MANUAL at 50'.IF hotwell level increasing, THEN direct RP to sample hotwells for activity.o Verify hotwell level-STABLE b.Check status of local actions to complete ruptured S/G isolation (Refer to Attachment RUPTURED S/G) l I h EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 34 of 38 STEP ACTION/EXPECTED'ESPONSE RESPONSE NOT OBTAINED 40 Energize PRZR Heaters As Necessary To Saturate PRZR Water At Ruptured S/G Pressure 41 Check RCP Cooling: a.Check CCW to RCPs: Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).o Annunciator A-7, RCP 1A CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED b.Check RCP seal injection:

o Labyrinth seal D/Ps-GREATER THAN 15 INCHES OF WATER-OR-o RCP seal injection flow to each RCP-GREATER THAN 6 GPM

EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 35 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED******xx x*0 xxxxx%xx'xx%'*x 4***x****x*******

CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST, THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATION.

                        • 4*4 x x w*~************'*********42 Check RCP Status: a.RCPs-AT LEAST ONE RUNNING b.Stop all but one RCP a.Perform the following:

1)Try to start one RCP: a)Ensure conditions for starting an RCP.o Bus llA or 11B energized.

o Refer to Attachment RCP START.b)IF RVLIS level (no RCPs)less than 95%, THEN perform the following:

o Increase PRZR level to greater than 65%(80%adverse CNMTj.o Dump steam to establish RCS subcooling based on core exit T/Cs to greater than 20'F using Figure MIN SUBCOOLING.

c)Start one RCP.2)IF an RCP can NOT be started, THEN verify natural circulation (Refer to Attachment NC).IF natural circulation can NOT be verified, THEN increase dumping steam.

ig$V J~w II'gl e EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 36 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.

43 Check If Source Range Detectors Should Be Energized:

a.Source range channels DEENERGIZED a.Go to Step 43e.b.Check intermediate range flux EITHER CHANNEL LESS THAN 10 10 AMPS b.Perform the following:

1)IF neither intermediate range channel is decreasing, THEN initiate boration.2)Continue with Step 44.WHEN flux is LESS THAN 10 amps on any operable channel, THEN do Steps 43c through e.c.Check the following:

o Both intermediate range channels-LESS THAN 10 10 AMPS c.Continue with Step 44.WHEN either condition met, THEN do Steps 43d and e.-OR-o Greater than 20 minutes since reactor trip d.Verify source range detectors ENERGIZED d.Manually energize source range detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).IF source ranges can'OT be restored, THEN refer to ER-NIS.1, SR MALFUNCTION and go to Step 44.e.Transfer Rk-45 recorder to one source range and one intermediate range channel I 4Q A~

EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 37 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 44 Establish Normal Shutdown Alignment:

a.Check condenser-AVAILABLE a.Dispatch AO to perform Attachment SD-2.b.Perform the following:

i o Open generator disconnects

~1G13A71~9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o Rotate reheater steam supply controller cam to close valves o Place reheater dump valve switches to HAND o Stop all but one condensate pump c.Verify adequate Rx head cooling: 1)Check IA to CNMT-AVAILABLE 2)Verify at least one control rod shroud fan-RUNNING 3)Verify one Rx compartment cooling fan-RUNNING 1)Go to Step 45.2)Manually start one fan as power supply permits (45 kw)3)Perform the following:

o Dispatch AO to reset UV relays at MCC C and MCC D.o Manually start one fan as power supply permits (23 kw)d.Verify Attachment SD-1-COMPLETE

~m ,~~l~l, EOP: E-3 LITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 38 of 38 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 45 Consult TSC To Determine Appropriate Post-SGTR Cooldown Procedure:

o Go to ES-3.1, POST-SGTR COOLDOWN USING BACKFILL, Step 1-OR-o Go to ES-3.2, POST-SGTR COOLDOWN USING BLOWDOWN, Step 1-OR-o Go to ES-'3.3, POST-SGTR COOLDOWN USING STEAM DUMP, Step 1-END-

~lt 4 elhi 7 X EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 1 of 1 E-3 APPENDIX LIST TITLE 1)RED PATH

SUMMARY

2)FIGURE MIN SUBCOOLING 3)ATTACHMENT CNMT RECIRC FANS 4)ATTACHMENT D/G STOP 5)ATTACHMENT N2 PORVS 6)ATTACHMENT NC 7)ATTACHMENT SEAL COOLING 8)ATTACHMENT RCP START 9)ATTACHMENT RUPTURED S/G 10)ATTACHMENT SD-1 11)ATTACHMENT SD-2 12)ATTACHMENT AUX BLDG SW 13)FOLDOUT PAGES 4

EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 1 of 1 RED PATH

SUMMARY

a.SUBCRITICALITY

-Nuclear power greater than 5~b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than 43~~[464 adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[25<adverse CNMT]AND total feedwater flow less than 200 gpm d.INTEGRITY-Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT

-CNMT pressure greater than 60 psig

'p V',II Ijf r'-Il+~" I'~f c I, I~4 EOP: E-3 TITLE: STEAM GENERATOR TUBE RUPTURE REV 15 PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below t'-]Core Exit T/C Indication RC 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 S PRESSURE (PSIG)RCS PRESSURE INCREMENTS 20 PSIG SUBCOOLED REGION E C DV ERS NORMAL CNMT INADEQUATE SUBCOOLING REGION TEMPERATURE INCREMENTS 10'F 200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEMPERATURE

(')

J'-

EOP: E-3 STEAM GENERATOR TUBE RUPTURE REV: 15 PAGE 1 of 1 SI REINITIATION CRITERIA FOLDOUT PAGE IF either condition listed below occurs, THEN operate SI pumps manually as necessary and go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1: o RCS subcooling based on core exit T/Cs-LESS THAN 0 F USING REQUIREMENTS OF FIGURE MIN SUBCOOLING.

OR 2 4 o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%[304 adverse CNMT).SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2, FAULTED S/G ISOLATION, Step 1.3~COLD LEG RECIRCULATION SWITCHOVER CRITERION 4.5.IF RWST level decreases to less than 284, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step l.AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).MULTIPLE S G TUBE RUPTURE CRITERIA IF any intact S/G level increases in in an uncontrolled manner OR IF any intact S/G has abnormal radiation, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 1.

tel 5t EOP: ECA-2'T1TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 31 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER RES 0 SIBLE MANAGER EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY

EOP: ECA-2-1 TLTLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 2 of 31 A.PURPOSE-This procedure provides actions to mitigate and minimize a loss of secondary coolant from both steam generators.

B.ENTRY CONDITIONS/SYMPTOMS 1-ENTRY CONDITIONS

-This procedure is entered from: a.E-2, FAULTED STEAM GENERATOR ISOLATION, when an uncontrolled depressurization of both steam generators occurs.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATZON OF BOTH STEAM GENERATORS REV: 12 PAGE 3 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF THE TDAFW PUMP IS THE ONLY AVAILABLE SOURCE OF FEED FLOW, THEN STEAM SUPPLY TO THE TDAFW PUMP MUST BE MAINTAINED FROM ONE S/G.*****************************************NOTE: o FOLDOUT page should be open AND monitored periodically.

o Conditions should be evaluated for Site Contingency Reporting (Refer to EPIP 1-0, GINNA STATION EVENT EVALUATION AND CLASSIFICATION).

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+R/hr.1 Check Secondary Pressure Boundary: o MSIVs-CLOSED o MFW flow control valves-CLOSED~MFW regulating valves~MFW bypass valves o MFW pump discharge valves CLOSED V o S/G blowdown and sample valves CLOSED Manually close valves one loop at a time.IF valves can NOT be closed, THEN dispatch AO to locally isolate flowpaths, as necessary, one loop at a time.o TDAFW pump steam supply valves PULL STOP o TDAFW pump flow control valves CLOSED o S/G ARVs-CLOSED o Dispatch AO to locally isolate S/Gs (Refer to Attachment FAULTED S/G)

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 4 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION A MINIMUM FEED FLOW OF 50 GPM MUST BE MAINTAINED TO EACH S/G WITH A NARROW RANGE LEVEL LESS THAN 5%[25%ADVERSE CNMT].*****************************************2 Control Feed Flow To Minimize RCS Cooldown: a.Check cooldown rate in RCS cold legs-'ESS THAN 100'F/HR b.Check narrow range level in both S/Gs-LESS THAN 50%a.Decrease feed flow to 50 gpm to each S/G and go to Step 2c.b.Control feed flow to maintain narrow range level less than 50%in both S/Gs.c.Check RCS hot leg temperatures STABLE OR DECREASING c.Control feed flow or dump steam to stabilize RCS hot leg temperatures.

3 Check If RCPs Should Be Stopped: a.RCP status-ANY RCP RUNNING b.SI pumps-AT LEAST TWO RUNNING c.RCS pressure minus maximum S/G pressure-LESS THAN 175 psig[400 psig adverse CNMT]d.Stop both RCPs a.Go to Step 4.b.Go to Step 4.'.Go to Step 4.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 5 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Check CST Level-GREATER THAN 5 FEET'witch to alternate AFW suction supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).*****************************************CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 5B).*5 Monitor PRZR PORVs And Block Valves: a.Power to PORV block valves AVAILABLE b.PORVs-CLOSED a.Restore power to block valves unless block valve was closed to isolate an open PORV:~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C b.IF PRZR pressure less than 2335 psig, THEN manually close PORVs.c.Block valves-AT LEAST ONE OPEN IF any PORV can NOT be closed, THEN manually close its block valve.IF block valve can NOT be closed, THEN dispatch AO to locally check breaker.~MOV-515, MCC C position 6C~MOV-516, MCC D position 6C c.'Open one block valve unless it was closed to isolate an open PORV.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 6 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 6 Check Secondary Radiation Levels-NORMAL o Steamline radiation monitor (R-31 and R-32)o Dispatch AO to locally check steamline radiation Go to E-3, STEAM GENERATOR TUBE RUPTURE, Step l.o Request RP sample S/Gs for activity*****************************************CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SW PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

7 Reset SI

EOP: ECA-2~1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV 12 PAGE 7 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION RCS PRESSURE SHOULD BE MONITORED.

IF.RCS PRESSURE DECREASES TO LESS THAN 250 PSIG[465 PSIG ADVERSE CNMT], THEN THE RHR PUMPS MUST BE MANUALLY RESTARTED TO SUPPLY WATER TO THE RCS.*8 Monitor If RHR Pumps Should Be Stopped: a.RHR pumps-ANY RUNNING b.Check RCS Pressure: a.Go to Step 9.1)Pressure-GREATER THAN 250 psig[465 psig adverse CNMT]2)Pressure-STABLE OR INCREASING 1)Go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step 1.2)Go to Step 9.c.Stop RHR pumps and place in AUTO

EOP: ECA-2~1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 8 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*9 Monitor If CNMT Spray Should Be Stopped: a.CNMT spray pumps-RUNNING b.Check the following:

o CNMT pressure-LESS THAN 4 PSIG a.Go to Step 10.b.Continue with Step 10.WHEN BOTH conditions satisfied, THEN do Steps 9c through f.o Sodium hydroxide tank level LESS THAN 55%c.Reset CNMT spray d.Check NaOH tank outlet valves CLOSED~AOV-836A~AOV-836B d.Place NaOH tank outlet valve controllers to MANUAL and close valves.~AOV-836A~AOV-836B e.Stop CNMT spray pumps and place in AUTO f.Close CNMT spray pump discharge valves~MOV-860A~MOV-860B~MOV-860C~MOV-860D, l~

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 9 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 10 Check RWST Level-GREATER THAN 284 Go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step l.ll Reset CI: a.Depress CI reset pushbutton b.Verify annunciator A-26, CNMT ISOLATION-EXTINGUISHED b.Perform the following:

1)Reset SI.2)Depress CI reset pushbutton.

12 Verify Adequate SW Flow: a.Check at least two SW pumps RUNNING a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN perform the following:

1),Ensure SW isolation.

2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)3)Go to Step 14.

EOP: ECA-2.1 T!TLE: UNCONTROLLED DEPRESSURXZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 10 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Establish IA to CNMT: a.Verify non-safeguards busses energized from offsite power o Bus 13 normal feed-CLOSED-OR-o Bus 15 normal feed-CLOSED b.Verify SW isolation valves to turbine building-OPEN~MOV-4613 and MOV-4670~MOV-4614 and MOV-4664 c.Verify at least two air compressors

-RUNNING d.Check IA supply: o Pressure-GREATER THAN 60 PSIG o Pressure-STABLE OR INCREASING e.Reset both trains of XY relays for IA to CNMT AOV-5392 f.Verify IA to CNMT AOV-5392-OPEN a.Perform the following:

1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Verify adequate emergency D/G capacity to run air compressors (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans should be stopped (Refer to Attachment CNMT RECIRC FANS).3)WHEN bus 15 restored, THEN reset control room lighting.b.Manually align valves.c.Manually start air compressors as power supply permits (75 kw each).IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.

d.Perform the following:

1)C'ontinue attempts to restore IA (Refer,to AP-IA.1, LOSS OF INSTRUMENT AIR).2)Continue with Step 14.WHEN IA restored, THEN do Steps 13e and f.

EOP: ECA-2'T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 11 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 14 Check If SI ACCUMs Should Be Isolated: a.Both RCS hot leg temperatures LESS THAN 400'F a.Go to Step 15.b.Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves~MOV-841, MCC C position 12F~MOV-865, MCC D position 12C c.Close SI ACCUM discharge valves~MOV-841~MOV-865 c.Vent any unisolated ACCUMs: 1)Open vent valves for unisolated SI ACCUMs,~ACCUM A, AOV-834A~ACCUM B, AOV-834B d.Locally reopen breakers for MOV-841 and MOV-865 2)Open HCV-945.15 Check Normal Power Available To Charging Pumps: o Bus 14 normal feed breaker CLOSED o Bus 16 normal feed breaker-CLOSED Verify adequate emergency D/G capacity to run charging pumps (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans can be stopped (Refer to.Attachment CNMT RECIRC FANS).

EOP;ECA-2.1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 12 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 16 Check If Charging Flow Has Been Established:

a.Charging pumps-ANY RUNNING a.Perform the following:

1)IF CCW flow is lost to any RCP thermal barrier OR any RCP¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal injection needle valve(s)to affected RCP:~RCP A, V-300A~RCP B, V-300B 2)Ensure HCV-142 open, demand at Oa.b.Align charging pump suction to RWST: o LCV-112B-OPEN o LCV-112C-CLOSED b.IF LCV-112B can NOT be opened, THEN perform the following:

1)Verify charging pump A NOT running and place in PULL STOP.c.Start charging pumps as'ecessary and adjust charging flow to restore PRZR level 2)Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).3)WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 13 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*17 Monitor SI Termination Criteria: a.SI pumps-ANY RUNNING b.Check RCS pressure: o Pressure-GREATER THAN 1625 psig[1825 psig adverse CNMT]o Pressure-STABLE OR INCREASING a.Go to Step 19.b.DO NOT stop SI pumps'~, Perform the following:

1)Energize PRZR heaters and operate PRZR spray as necessary to stabilize RCS pressure greater than 1625 psig[1825 psig adverse CNMT)c.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING 2)Return to Step 2.c.DO NOT stop SI pumps.Return to Step 2.d.PRZR level-GREATER THAN 5%[30%adverse CNMT)d.Do NOT stop SI pumps.Perform the following:

1)IF normal'PRZR spray available, THEN try to stabilize RCS pressure with PRZR spray, 2)Return to Step 17a.NOTE: Foldout Page E-2 transition criteria does not apply while performing steps 18 and 19.18 Stop SI and RHR Pumps And Place In Auto

EOP: ECA 2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 14 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*19 Monitor SI Reinitiation Criteria: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Manually operate SI pumps as necessary and return to Step 2.b.PRZR level-GREATER THAN 5%[30%adverse CNMT]b.Control charging flow to maintain PRZR level.IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary and return to Step 2.20 Check RCS Hot Leg Temperatures

-STABLE OR DECREASING Control feed flow or dump steam to stabilize RCS hot leg temperatures.

21 Check Narrow Range Level In Both S/Gs-LESS THAN 504 Control feed flow to maintain narrow range level less than 50%in both S/Gs.22 Verify Adequate SW Flow To CCW Hx: a.Verify at least two SW pumps RUNNING b.Verify AUX BLDG SW isolation valves-OPEN~MOV-4615 and MOV-4734~MOV-4616 and MOV-4735 a.Manually start pumps as power supply permits (258 kw per pump).IF less than two SW pumps can be operated, THEN go to Step 28'.Establish SW to AUX BLDG (Refer to Attachment AUX BLDG SW).c.Verify CNMT RECIRC fan annunciator C-2, HIGH TEMPERATURE AIARM-EXTINGUISHED c.Dispatch AO to locally throttle flow to CCW Hx to between 5000 gpm and 6000 gpm total flow.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 15 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 23 Check If Normal CVCS Operation Can Be Established a.Verify IA restored: o IA to CNMT (AOV-5392)

-OPEN o IA pressure-GREATER THAN 60 PSIG a.Continue with Step 28.WHEN IA restored, THEN do Steps 23 through 27.b.Verify instrument bus D-ENERGIZED b.Energize MCC B.IF MCC B NOT available, THEN perform the following:

c.CCW pumps-ANY RUNNING d.Charging pump-ANY RUNNING 1)Verify MCC A energized.

2)Place instrument bus D on maintenance supply.c.Perform the following:

1)IF any RCP¹1 seal outlet temperature of f scale high, THEN isolate CCW to thermal barrier of affected RCP(s).~RCP A, MOV-749A and MOV-759A~RCP B, MOV-749B and MOV-759B 2)Manually start one CCW pump.d.Continue with Step 28.WHEN any charging pump running, THEN do Steps 24 through 27.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 16 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 24 Verify PRZR Level-GREATER THAN 134[40%adverse CNMT]Continue with Step 26.WHEN PRZR level increases to greater than 13%[40%adverse CNMT], THEN do Step 25.25 Establish Normal Letdown: a.Verify charging line flow to REGEN Hx-GREATER THAN 20 GPM b.Place the following switches to CLOSE:~Letdown orifice'valves (AOV-200A, AOV-200B, and AOV-202)~AOV-371, letdown isolation valve~AOV-427, loop B cold leg to REGEN Hx c.Place letdown controllers in MANUAL at 40%open~TCV-130~PCV-135 d.Reset both trains of XY relays for AOV-371 and AOV-427 e.Open AOV-371 and AOV-427 IF RCP seal return has been established, THEN establish excess letdown as follows: o Place excess letdown divert valve, AOV-312, to NORMAL.o Ensure CCW from excess letdown open, (AOV-745).

o Open excess letdown isolation'alve AOV-310.o Slowly open HCV-123 to maintain excess letdown temperature less than 195'F and pressure less than 100 psig.o Adjust charging pump speed as necessary.

IF RCP seal return NOT established, THEN consult TSC to determine if excess letdown should be placed in service.f.Open letdown orifice valves as necessary g.Place TCV-130 in AUTO at 105'F h.Place PCV-135 in AUTO at 250 psig i.Adjust charging pump speed and HCV-142 as necessary

EOP: ECA-2.1 T1TLE UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 17 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 26 Check VCT Makeup System: a.Adjust boric acid flow control valve in AUTO to 9.5 gpm b.Adjust RMW flow control valve in AUTO to 40 gpm c.Verify the following:

1)RMW mode selector switch in AUTO c.Adjust controls as necessary.

2)RMW control armed-RED LIGHT LIT d.Check VCT level: o Level-GREATER THAN 20%-OR-o Level-STABLE OR INCREASING d.Manually increase VCT makeup flow as follows: 1)Ensure BA transfer pumps'and RMW pumps running.IF NOT, THEN reset MCC C and MCC D UV lockouts as necessary.

2)Place RMW flow control valve HCV-111 in MANUAL and increase RMW flow.3)Increase boric acid flow as necessary.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURXZATION OF BOTH STEAM GENERATORS REV 12 PAGE 18 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 27 Check Charging Pump Suction Aligned To VCT: a.VCT level-GREATER THAN 20%a.IF VCT level can NOT be maintained greater than 5%, THEN perform the following:

1)Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed 2)Continue with Step 28.WHEN VCT level greater than 40%, THEN do'tep'7b.

b.Verify charging pumps aligned to VCT: o LCV-112C-OPEN o LCV-112B-CLOSED b.Manually align valves as necessary.

EOP: ECA-'2.1 TITLES UNCONTROLLED DEPRESSURXZATZON OF BOTH STEAM GENERATORS REV 12 PAGE 19 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 28 Check RCP Cooling: a.Check CCW to RCPs: Establish normal cooling to RCPs~(Refer to Attachment SEAL COOLING).o Annunciator A-7, RCP lA CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED b.Check'RCP seal injection:

o Labyrinth seal D/Ps-GREATER THAN 15 INCHES OF WATER-OR-o RCP seal injection flov to each RCP-GREATER THAN 6 GPM

EOP: ECA-2.1 T1TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 20 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 29 Check If Seal Return Flow Should Be Established:

a.Verify RCP¹1 seal outlet temperature

-LESS THAN 235'F b.Verify RCP seal outlet valves OPEN a.Go to Step 30.b.Manually open valves as necessary.

~AOV-270A~AOV-270B c.Reset both trains of XY relays for RCP seal return isolation valve MOV-313 d.Open RCP seal return isolation valve MOV-313 e.Verify RCP¹1 seal leakoff flow LESS THAN 6.0 GPM d.Perform the following:

1)Place MOV-313 switch to OPEN.2)Dispatch AO with key to RWST gate to locally open MOV-313.e.Perform the following:

1)Trip the affected RCP 2)Allow 4 minutes for pump coast down, THEN close the affected RCP seal discharge valve f.Verify RCP¹1 seal leakoff flow GREATER THAN 0.8 GPM~RCP A, AOV-270A~RCP B, AOV-270B IF both RCP seal discharge valves are shut, THEN go to Step 30.f.Refer to AP-RCP.1, RCP SEAL MALFUNCTION.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 21 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.o When using PRZR PORV, select one with an operable block valve.30 Energize Heaters And Operate Normal Spray As Necessary To Maintain RCS Pressure Stable IF normal'pray NOT available and letdown is in service, THEN use auxiliary spray valve (AOV-296).

IF PRZR spray NOT'vailable', THEN use one PRZR PORV.IF IA NOT available, THEN refer to Attachment N2 PORVS.

C EOP: ECA-2.1'1ILE:

UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV 12 PAGE 22 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 31 Verify All, AC Busses-ENERGIZED BY OFFSITE PONER o Normal feed breakers to all 480 volt busses-CLOSED o 480 bus voltage-GREATER THAN 420 VOLTS o Emergency D/G output breakers OPEN Perform the following:

a.IF any AC emergency bus normal feed breaker open, THEN ensure associated D/G breaker closed.b.Perform the following, as necessary:

1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~'Bus 15 to Bus 16 tie 2)Place the following pumps in PULL STOP:~EH pumps~Turning gear oil pump~HP seal oil backup pump 3)Restore power to MCCs.~A from Bus 13 4 B from Bus 15~E from Bus 15~F from Bus 15 4)WHEN bus 15 restored, THEN reset control room lighting..

5)Refer to Attachment SI/UV for other equipment lost with loss of offsite power.c.Try to restore offsite power to all AC busses (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).

I EOP: ECA-2 1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 23 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST, THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATIONS 32 Check RCP Status-'T LEAST ONE RUNNING Try to start one RCP: a.Establish conditions for starting an RCP.o Bus 11A or 11B energized I o Refer to Attachment RCP START.b.Start one RCP.IF an RCP can NOT be started, THEN verify natural circulation (Refer to Attachment NC).IF natural circulation can NOT be verified, THEN increase feed flow or dumping steam.

ilk EOP: ECA-2~1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 24 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED I NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.

33 Check If Source Range Detectors Should Be Energized:

a.Source range channels DEENERGIZED a.Go to Step 33e.b.Check intermediate, range flux-EITHER CHANNEL LESS THAN 10 10 AMPS b.Perform the following:

1)IF neither intermediate range channel is decreasing THEN initiate boration.2)Continue with Step 34.WHEN flux is LESS THAN 10 amps on any operable channel, THEN do Steps 33c, d and e.c.Check the following:

o Both intermediate range channels-LESS THAN 10-10 AMPS c.Continue with step 34.WHEN either condition met, THEN do Steps 33d and e.-OR-o Greater than 20 minutes since reactor trip d.Verify source range detectors ENERGIZED d.Manually energize source'range detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).e.Transfer Rk-45 recorder'to one source range and one intermediate range channel.IF source ranges can NOT be restored, THEN refer to ER-NIS.l, SR MALFUNCTION and go to Step 34.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 25 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 34 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN a.Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).o AC emergency bus voltage GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED b.Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 26 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 35 Establish Normal Shutdown Alignment:

a.Check condenser-AVAILABLE a.Dispatch AO to perform Attachment SD-2.b, Perform the following:

o Open generator disconnects

~1G13A71~9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o Rotate reheater steam supply controller cam to close valves o Place reheater dump valve switches to HAND o Stop all but one condensate pump c.Verify adequate Rx head cooling: 1)Verify at least one control rod shroud fan-RUNNING 1)Manually start one fan as power supply permits (45 kw)2)Verify one Rx compartment cooling fan-RUNNING 2)Perform the following:

o Dispatch AO to reset UV relays at MCC C and MCC D.o Manually start one fan as power supply permits (23 kw)d.Verify Attachment SD-1-COMPLETE

EOP: ECA-F 1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 27 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 36 Maintain Plant Conditions-STABLE Control plant systems as necessary to maintain conditions stable.o RCS pressure o PRZR level o RCS temperatures

  • 37 Monitor SI Reinitiation Criteria: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Manually operate SI pumps as necessary.

Return to Step 2.b.PRZR level-GREATER THAN 5%[30%adverse CNMT)b.Control charging flow to maintain PRZR level.IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary.

Return to Step 2~

'I'4 EOP: ECA-F 1 T1TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 28 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 38 Check If SI ACCUMs Should Be Isolated: a.Check the following:

o RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING a.Go to Step 39.o PRZR level-GREATER THAN 5%[30%adverse CNMT]b.Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves~MOV-841, MCC C position 12F~MOV-865, MCC D position 12C c.Close SI ACCUM discharge valves~MOV-841~MOV-865 c.Vent any unisolated ACCUMs: 1)Open vent valves for unisolated SI ACCUMs.d.Locally reopen breakers for MOV-841 and MOV-865~ACCUM A;AOV-834A~ACCUM B, AOV-834B 2)Open HCV-945.

EOP: ECA-2~1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 29 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 39 Check RCS Hot Leg Control feed flow and dump steam to Temperatures

-LESS THAN 350'F.establish RCS cooldown rate less than 100'F/hr in RCS cold legs.NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.o When using PRZR PORV, select one with operable block valve.40 Check RCS Pressure-LESS THAN 400 PSIG[300 PSIG adverse CNMT]e Use normal PRZR spray.IF normal spray NOT available and letdown is in service, THEN use auxiliary spray.IF NOT, THEN use one PRZR PORV.IF IA NOT available, THEN refer to Attachment N2 PORVS.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 30 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 41 Check If RHR Normal Cooling Can Be Established:

a.RCS cold leg temperature

-LESS THAN 350'F a.Return to Step 37'.RCS pressure-LESS THAN 400 psig[300 psig adverse CNMT]c.Place letdown pressure controller (PCV-135)in MANUAL CLOSED b.Return to Step 40.d.Check following valves-OPEN~AOV-371, letdown isolation valve~AOV-'427, loop B cold leg to REGEN Hx~At least one letdown orifice valve (AOV-200A, AOV-200B, or AOV-202)d.Perform the following:

1)Reset both trains of XY relays for AOV-371 and AOV-427')Open AOV-371 and AOV-427.3)Open one letdown orifice valve.e.Verify pressure on PI-135-LESS THAN 400 PSIG e.Return to Step 40.f.Place RCS overpressure protection system in service (Refer to 0-7, ALIGNMENT AND OPERATION OF THE REACTOR VESSEL OVERPRESSURE PROTECTION SYSTEM)g.Establish RHR normal cooling (Refer to Attachment RHR COOL)f.IF RCS overpressure protection system can NOT be placed in service, THEN notify TSC of potential Tech Spec violation if RHR system is placed in service.

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 31 of 31 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 42 Continue RCS Cooldown To Cold Shutdown: a.Maintain cooldown rate in RCS cold legs-LESS THAN 100'F/HR ,b.Check narrow range level in both S/Gs-LESS THAN 50%b.Control feed flow to maintain narrow range level less than 50%'n both S/Gs.43 Check Core Exit T/Cs-LESS THAN 200'F Return to Step 42.44 Evaluate Long Term Plant Status: a.Maintain cold shutdown conditions b.Consult TSC-END-

EOP: TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 ECA-2.1 APPENDIX LIST TITLE 1)RED PATH

SUMMARY

2)FIGURE MIN SUBCOOLING 3)ATTACHMENT FAULTED S/G 4)ATTACHMENT CNMT RECIRC FANS 5)ATTACHMENT NC 6)-ATTACHMENT RCP START 7)ATTACHMENT N2 PORVS 8)ATTACHMENT SEAL COOLING 9)ATTACHMENT SI/UV 10)ATTACHMENT D/G STOP 11)ATTACHMENT SD-1 12)ATTACHMENT SD-2 13)ATTACHMENT RHR COOL 14)ATTACHMENT AUX BLDG SW 15)FOLDOUT PAGES

EOP: ECA-2.1 T!TLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 RED PATH

SUMMARY

a.SUBCRITICALITY

-Nuclear power greater than 54 b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than 43%[464 adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[254 adverse CNMT]AND total feedwater flow less than 200 gpm d.INTEGRITY-Cold.leg temperatures decrease greater than 100'F'in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT

-CNMT pressure.greater than,60 psig

EOP: ECA-2.1 TITLE: UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below[-]Core Exit T/C Indication S PRESSURE (PSIG)RC 2500 2400 2300 2200 2100 2000 1900'800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 20 RCS PRESSURE INCREHENTS 20 PSIG SUBCOOLED REGION INADEQUATE SUBCOOLING REGION ADVERSE CNHT TEHPERATURE INCREHENTS 10'F NORHAL CNHT 0'50 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEHPERATURE

('F)

EOP!ECA-2.1 TITLE!UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS REV: 12 PAGE 1 of 1 FOLDOUT PAGE 1.SI REINITIATION CRITERIA Manually operate SI pumps as necessary if EITHER condition listed below occurs: o RCS subcooling based on core exit TCs-LESS THAN O'F USING REQUIREMENTS OF FIGURE MIN SUBCOOLING o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 54[304 ADVERSE CNMT]2.E-2 TRANSITION CRITERIA IF any S/G pressure increases at any time (except while performing SI termination in Steps 18 and 19), THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step 1.3.COLD LEG RECIRCULATION SWITCHOVER CRITERION IF RWST level decreases to less than 284, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step 1.4.LOSS OF EMERGENCY COOLANT RECIRCULATION CRITERION IF emergency coolant recirculation is established and subsequently lost, THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION,'Step 1.5.AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.l, ALTERNATE WATER SUPPLY TO AFW PUMPS).