Revised Emergency Operating Procedures,Including Rev 5 to Att-10.0, Attachment Faulted S/G & Rev 6 to Att-16.0, Attachment Ruptured S/G
ML20128N068
Person / Time
Site: Ginna 
Issue date: 10/03/1996
From: Whits T
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17264A686 List:
References
PROC-961003, NUDOCS 9610160282
Download: ML20128N068 (5)


Text

-. _

O EC':

REV: 5

.ATT-10.0 ATTACHMENT FAULTED S/G PAGE 1 of 2 WA4 !

t Date /d-3-$

Responsible Manager

/

Dispatch AO with locked valve key to complete local isolation of faulted S/G as follows:

NQTE:

Intermediate Building environment should be assessed for radiological or other personnel safety concerns.

-1.

Request identification of faulted S/G from Control Room.

NOTE:

Steps may be done in any order, 1

2.

Verify faulted S/G MSIV bypass valve closed (INT BLDG steam header area) o S/G A, V-3615

-O R-o S/G B, V-3614 3.

Isolate steamlines for the faulted S/G:

o Steam sampling system (INT BLDG steam header area) o S/G A, close V 3413A O R-0 S/G B, close V-3412A o

Support heating steam (INT BLDG steam header area) o S/G A, close V-3669 O R-0 S/G B, close V 3668 o

Upstream trap'3 (TURB BLDG east of MFW regulating valves) o S/G A, close V-3521 OR-0 S/G B, close V 3520 9610160282 961003 PDR ADOCK 05000244 Y

PDR

goes ritLE:

REV: 5 1

I i

$TT-10.0 ATTACHMENT FAULTED S/G PAGE 2 of 2 O

CAUTION CONTROL ROOM SHOULD BE NOTIFIED BEFORE ISOLATING TDAFW PUMP l

STEAM OR FEED FLOW.

4.

'..,cally CLOSE TDAFW pump steam root valves o

S/G A, V-3505

-O R-0 S/G B, V-3504 5.

Locally close TDAFW pump feed header isolation valve for affected S/G:

o S/G A, V-4005 (steam header west end on catwalk by CNMT wall)

I

-O R-0 S/G B, V-4006 (Main steam header east end by stairs) 6.

Locally close MFW regulating valve and bypass valve outlet isolation valves for the faulted S/G:

o S/G A, V-3987 and V,991

-O R-o S/G B, V-3986 and V-3990

k3 go :

rirtt:

REVi 6

'ATT-16.0 ATTACHMENT RUPTURED S/G PAGE 1 of 3 O

Responsible Manager Lov/[L J

Date /d-3-9/,

/

NOTE:

Intermediate Building environment should be assessed for radiological and other personnel safety concerns.

PART A.

Dispatch AO with locked valve key to complete localisolation of l

ruptured S/G as follows:

l NOTE:

Steps may be done in any order for PART A.

l CAUTION l

CONTROL ROOM SHOULD BE NOTIFIED BEFORE ISOLATING TDAFW PUMP l

STEAM OR FEED FLOW.

1)

Verify BOTH S/G MSIV bypass valves closed (INT BLDG steam header area):

o S/G A, V-3615 o

S/G B, V-3614 l

l 2)

Locally close TDAFW pump steam root valves o

S/G A, V-3505

-O R-O S/G B, V 3504 l

3)

Locally close the following steam valves from the ruptured S/G:

l o

Steam to sampling system valve (INT BLDG steam header area):

S/G A, close V-3413A O R-S/G B, close V 3412A l

l 0

Support heating steam valve (INT BLDG steam header area):

I S/G A, close V 3669

-O R-

>0 s'o 8.ci v see8 l

EOP:

ilfLE REV: 6 i

$TT-16.0 i

ATTACHMENT RUPTURED S/G PAGE 2 of 3 f~

\\

o Upstream trap isolation valve (TURB BLDG near MFW reg vivs):

S/G A, close V-3521

-O R-S/G B, close V 3520 4)

Locally close TDAFW pump manual feedwater isolation valve to ruptured S/G (INT BLDG steam header area):

S/G A, V 4005

-O R-S/G B, V-4006 k

5)

Bypass condensate polishing demineralizers as follows:

1 1.

Place AVT bypass valve controller in MANUAL (east end of AVT panel).

I 2.

Open bypass valve.

3.

Isolate _A.LLiinservice demineralizers as follows:

a)

Place the Mixed Bed Service Selector switch to override AND select the bed to be removed from service.

j b)

Place the 4 position selector switch for the selected bed to OFF.

l c)

Repeat steps a and b for each inservice bed.

]

i 6)

Locally place TURB RM WALL EXH FAN switches to CLOSE.

7)

Locally place TURB RM ROOF VENT switches to CLOSE.

l CAUTION l

PART B OF THIS ATTACHMENT SHOULD ONLY BE PERFORMED IF RUPTURED

)

S/G MSIV CANNOT BE CLOSED.

1 PART B.

Dispatch AO to locally perform the following when ruptured S/G MSIV cannot be closed, if areas are accessible:

l 1)

Close Air Ejector / Gland steam root valve, V-3540 (Main steam header TURB j

BLOG).

2)

Close flange heating isolation valves, MOV-3601 A and MOV 3602A.

tops ilfLE:

REW 6 ATT-16.0 ATTACHMENT RUPTURED S/G PAGE 3 of 3 l

\\

3)

Notify Control Room that main flowpaths are isolated, THEN complete isolation by closing the following valves:

NOTE:

Substeps may be done in any order.

a)

MFW regulating valve and bypass valve manualisolation valves for both S/Gs:

o S/G A, V-3985 and V-3989 l

o S/G B, V-3984 and V-3988 l

b)

Reheat steam chain valves:

l 0

1 A MSR, V-3551 l

0 18 MSR, V-3550 0

2A MSR, V-3553 o

28 MSR, V-3552 c)

Steam dump header isolation and bypass valves (Main steam header TURB BLDG on platform overhead) o V-3532 and V-3659 o

V-3533 and V-3658 d)

Reheat steamline warmup valves (warmup vivs located east end of 1 A and 2A MSRs TURB BLDG middle floor):

l o

V-3645 o

V-3646 o

V 3647 o

V-3648 e)

Reheat steamline common vent, V-8500 (at condenser north of 1 A l

MSR).

l f)

Steam to trap header isolation valves o

V-8513 (Main steam header TURB BLDG) o V-8529 (south side EH skid) o V-8510 (south side EH skid) s l

-.