{{#Wiki_filter:(0ROCHESTER GASANDELECTRICCORPORATION GINNASTATIONCONTROLLED COPYNUMBERPROCEDURE NO.PT-17.4CONTROLROOMRADIATION R-36R-37R-38ANDTOXICGASMONITOROPERABILITY TESTTECHNICAL REVIEWPORCREVIEWDATE(0PLANTSUPERINTENDENT EFFECTIVE DATECATEGORY1.0REVIEWEDBY:THISPROCEDURE CONTAINS19PAGESGINNASTATIONSTART:DATETIMECOMPLETED:
{{#Wiki_filter:ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION (0                        CONTROLLED COPY NUMBER PROCEDURE NO.       PT-17.4 CONTROL ROOM RADIATION  R-36  R-37              R-38 AND TOXIC GAS MONITOR OPERABILITY TEST TECHNICAL REVIEW PORC REVIEW DATE (0                              PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY  1.0 REVIEWED BY:
DATETIME'510260343 951018PDRADOCK05000244pPDR PT-17.4:1 PT-17.4CONTROLROOMRADIATION R-36R-37R-38ANDTOXICGASMONITOROPERABILITY TEST1.0PURPOSE:Todescribethestepsnecessary toverifytheoperability oftheControlRoomparticulate, IodineandNobleGasradiation monitors.
GINNA STATION THIS PROCEDURE CONTAINS        19 START:
1.2Todescribethestepsnecessary toverifytheoperability oftheAmmoniaandChlorinedetectors.
PAGES DATE TIME COMPLETED:
DATE TIME'510260343 951018 PDR  ADOCK  05000244 p                PDR


==2.0 TESTREUIREMENTS==
PT-17.4:1 PT-17.4 CONTROL ROOM RADIATION R-36    R-37  R-38 AND TOXIC GAS MONITOR OPERABILITY TEST
2.j.'.2Particulate, IodineandNobleGasradiation detectors alarmandautomatic actionstakeplaceasspecified.
AmmoniaandChlorinedetectors alarmandautomatic actionstakeplaceasspecified.
2.3Radiation detectorresponsetoinstalled checksourceisverified.2.4AmmoniaandChlorinedetectors respondtospangases.2.52.6Radiation monitorandtoxicgasdetectorflowswitchesactuateandautomatic actionstakeplaceasspecified.
Completion ofSystem/Equipment Independent Verification Che'ck.


==3.0REFERENCES==
==1.0 PURPOSE==
:
To describe the steps necessary to verify the operability of the Control Room particulate, Iodine and Noble Gas radiation monitors.
3.1PlantTechnical Specifications 4.5.2.3.9, 3.5.6andTab'e4.1-1.3.23.33.43.5NRCOperation andMaintenance Manual.FoxboroOperation andMaintenance Manual.Independent Verification Procedure, A-1408.ResultsandTestAcceptance CriteriaBasis(ACB)File.
1.2      To describe the steps necessary to verify the operability of the Ammonia and Chlorine detectors.
PT-17.4:2 3.5.1Key:BasisforLimits/Values V-VendorE-Engineering A-Administrative C-CodeT-TechSpec4.0INITIALCONDITIONS:
2.0      TEST RE UIREMENTS:
4.14.2Plantinanymodeofoperation.
: 2.       Particulate,   Iodine and Noble Gas radiation detectors j.'.2 alarm and automatic actions take place as specified.
NotifyShiftSupervisor atstartoftest.4.3NotifyHCOatstartoftest.4.4NotifyQCDept.atstartoftest.4.5,'estpersonnel arequalified inaccordance withA-1102.4.6Priortoperforming operability testofthechlorinedetector, determine whichsectionwillbeused,andmarktheotherN/A.4.6.1Chlorinebottlecalibration testgas(Section6.9).4.6.2Chlorinemastcalibration unit(Section6.10).NOTE:TheTech.Spec.channelfunctional testpowerfailurerequirement issatisfied duringthesuccessful performance ofeachindividual channel,highalarm/trip setpointcheck.4.7Ifthesetpointforaradiation detectoralarmand/ortripisfoundtobehigherthanrequired, notifyShiftSupervisor andtakeoneofthefollowing actionsimmediately'.
Ammonia and Chlorine detectors        alarm and automatic actions take place  as specified.
4.81)Thesetpointshallbeimmediately corrected withoutdeclaring thechannelinoperable; or2)Declarethechannelinoperable.
2.3     Radiation detector response to installed check source is veri fied.
Theindividual performing theindependent verification shallbeapersonknowledgeable intheappropriate systeminvolved, normallyanAuxiliary OperatororLicensees Operator(activeorinactive).
2.4      Ammonia and Chlorine detectors respond to span gases.
PT-17.4:34.8.1Theinitialrealignment stepsmaybeperformed atvariouspointsthroughout theprocedure, however,theIndependent Verification Checkshallbeperformed uponcompletion oftestingeachindividual trainpriortoproceeding toanyothertrain.4~8.2Duetothefrequenttripping/resetting oftheControlRoomVentilation System,thetotalcharcoalruntimeloggedonT-31.10,Attachment 1,shallbefrominitialtriportimeinitially placedintherecircmode,totimeoffinalreset.4.9IfPPCSisinoperable, N/Astepsverifying PPCSresponse.
2.5      Radiation monitor and toxic gas detector flow switches actuate and automatic actions take place as specified.
5.05.1PRECAUTIONS:
2.6      Completion of System/Equipment    Independent   Verification Che'ck.
Observenormalcompanysafetypractices.
 
5.2Anydeviations fromstatedlimitsinthisprocedure shouldbenotedundercommentsandaWR/TRinitiated whenapplicable.
==3.0      REFERENCES==
5.3PriortoopeningAmmoniaorChlorinebottle,verifyregulators areback-seated andbottlespipedtodetectors.
3.1      Plant Technical Specifications 4.5.2.3.9, 3.5.6 and Tab'e 4.1-1.
5'CareshouldbetakenwhenhandlingAmmonia(60ppm)andChlorinebottles(3.0ppm)sincethesearetoxicsubstances.
3.2      NRC  Operation and Maintenance Manual.
PT-17.4:46.0INSTRUCTIONS:
3.3      Foxboro Operation and Maintenance Manual.
NQTE1:Sectionsnottobeperformed maybemarkedN/Aifnotapplicable.
3.4     Independent  Verification  Procedure,  A-1408.
NOTE2:Testingofradiation detectors maycauseaspikeononeoftheLEDreadoutsofthedetectors.
3.5     Results and Test Acceptance Criteria Basis      (ACB) File.
Thisisindicated byanillegible reading.TheLEDmustberesetbymomentarily interrupting powertothatdetector(turnpowerswitchinsidedrawerto"OFF"position, thenreturnto"ON").NOTE3:Duringtheperformance ofthistest,R-36,37or38maygointoalarmduetosystemtransient causedbytesting.Ifthisoccurs,ensuretheapplicable channelislessthanthealarm/warning
 
: setpoint, resetbydepressing theapplicable warning/alarm pushbutton, andresetcontrolroomventilation ifnecessary.
PT-17.4:2 3.5.1 Key: Basis  for Limits/Values V  Vendor E  - Engineering A   Administrative C  - Code T - Tech Spec 4.0  INITIAL CONDITIONS:
NOTE4:'nytimemonthlysurveillance isperformed, totalcharcoalfilterfanruntimemustbeaminimumof15minutes.6.1CHARCOALFILTERFANOPERATION:
4.1  Plant in any  mode  of operation.
6.3..1VerifyControlRoomHVACsystemisinaccidentmodeorplacesystemin"Accident Mode"bydepressing ControlRoomManualIsolation Pushbutton.
4.2  Notify Shift Supervisor at start of test.
6.1.2Logtimethatcharcoalfilterfanstarts.Time6.1.3After15minuteruntime,stopthecharcoalfilterfanbydepressing theControlRoomIsolation ResetPushbutton.
4.3  Notify HCO at start of test.
6.1.4Logtimethatcharcoalfilterfanstops.Time6.2ListP-9"ALMQ4"setpoints inblanksprovided.
4.4  Notify QC Dept. at start of test.
R-36[R-37[R-38[cpmabovebackground]
4.5,'est    personnel are qualified in accordance with A-1102.
cpm]cpmabovebackground]
4.6  Prior to performing operability test of the chlorine detector, determine which section will be used, and mark the other N/A.
PT-17.4:5 6.2.1ListP-9"WARNING" setpoints inblanksprovided.
4.6.1 Chlorine bottle calibration test gas (Section 6.9).
R-36[R-37[R-38[cpmabovebackground]
4.6.2 Chlorine mast calibration unit (Section 6.10).
cpm]cpmabovebackground]
NOTE:       The Tech. Spec. channel functional test power failure requirement is satisfied during the successful performance of each individual channel, high alarm/trip setpoint check.
'6.3R-36NOBLEGASMONITOR6.3.1AtR-36monitordrawer,record'!asfound"Alarmsetting.cpm6.3.2SetR-36AlarmsettingtotheP-9"ALARM"setpoint.
4.7  If the setpoint for a radiation detector alarm and/or trip is found to be higher than required, notify Shift Supervisor and      take  one  of the  following actions immediately'.
cpm6.3.3.AtR-36monitordrawer,recordsetting."asfound"Warningcpm6.3.4SetR-36WarningSettingtotheP-9"WARNING" setpoint.
: 1)   The  setpoint shall be immediately corrected without declaring the channel inoperable; or
cpm6'.5Presschecksourceandverifythefollowing:
: 2)   Declare the channel inoperable.
6.3.5.1Channel.digitaldisplayindicates greaterthan"ALARM"setpointaslistedinstep6.3.2.6.3.5.26.3.5.3ChannelWarninglight(orange)illuminates.
4.8  The individual performing the independent verification shall be a person knowledgeable in the appropriate system involved, normally an Auxiliary Operator or Licensees Operator (active or inactive).
ChannelAlarmlight(red)illuminates.
 
6.3.5.4MCBalarmE-11(ControlRoomHVACIsolation) annun-ciates.6.3.5.5Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltothe.closedpositionas'indicated bystatuslights.6.3.5.6Charcoalfilterfanstarts.6.3.5.7RecircdampersAKD07andAKD09open(inAirHandli.".g Room).6.3.6ResetControlRoomHVACSystemwhendigitaldisplaydecreases below"ALARM"setpointandverifyt!;efollowing:
PT-17. 4: 3 4.8.1  The  initial realignment  steps may be performed at various points throughout  the procedure, however, the Independent Verification  Check  shall  be performed upon completion of testing each  individual  train prior to proceeding to any other train.
6.3.6.1Outsideairinlet,exhaustreliefandtoiletexhausdamperstraveltotheOPENpositionasindicated
4  8.2 Due  to the frequent tripping/resetting of the Control Ventilation System, the total charcoal run time
."ystatuslights.
  ~
PT-17.4:6 6.3.6.1.1 RecircdampersAKD07andAKD09close(inAirHandlingRoom).6.3.6.26.3.6.36.3.76.3.7'6.3'.2Charcoalfilterfanisoff.MCBannunciator E-11clears.IndeendentVerification Check:R-36Alarmsettostep6.3.2setting.R-36Warningsettingsettostep6.3.4setting.6.4R-37PARTICULATE MONITOR6'.16.4.26.4.36.4.4AtR-37monitordrawer,record"asfound"Alarmsetting.cpmSetR-37AlarmsettingtotheP-9"ALARM"setpoint.
Room logged on T-31.10, Attachment 1, shall be from initial trip or time initially placed in the recirc mode, to time of final reset.
cpmiAtR-37monitordrawer,record"asfound""WARNING" setting.cpmSetR-37"WARNING" settingtotheP-9"WARNING" setpoint.
4.9    If PPCS  is inoperable,  N/A steps  verifying PPCS response.
6.4.56.4.5.1cpmPresschecksourceandverifythefollowing:
 
Channeldigitaldisplayindicates greaterthan"ALARM"setpointaslistedinStep6.4.2.6.4.5.2ChannelWarninglight(orange)illuminates.
==5.0 PRECAUTIONS==
6.4.5.36.4.5.4ChannelAlarmlight(red)illuminates.
5.1     Observe normal company safety      practices.
MCBalarmE-11(ControlRoomHVACIsolation) annunciates.
5.2    Any  deviations from stated limits in this procedure should be noted under comments and a WR/TR initiated when applicable.
6.4.5.5Outsideairinlet,exhaustreliefandtoiletexhaus.damperstraveltotheCLOSEDpositionasindicated hystatuslights.6.4.5.6Charcoalfilterfanstarts.
5.3    Prior to opening Ammonia or Chlorine bottle, verify regulators are back-seated          and bottles      piped to detectors.
PT-17.4:7 6.4.6ResetControlRoomHVACSystemwhendigitaldisplaydecreases below"ALARM"setpointandverifythefollow-ing:6.4.6.1Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatuslights.6.4'.2Charcoalfilterfanisoff.6.4.6.3MCBannunciator E-llalarmclears.6.4.7Independent Verification Check:6.4.7.16.4.7.2R-37AlarmtoStep6.4.2setting.R-37"WARNING" settingsettoStep6.4.4setting.6.5R-38IODINEMONITOR:6.5.1AtR-38setting.monitordrawer,record"asfound"Alarmcpm6'.2SetR-38AlarmsettingtotheP-9"AIAfQI"setpoint.
5'      Care should be taken when handling Ammonia        ( 60 ppm) and Chlorine bottles      (  3.0  ppm)  since  these  are  toxic substances.
cpm6.5.3AtR-38setting.monitordrawer,record"asfound"Warningcpm6.5.46.5.56.5.5.16.5.5.2SetR-38WarningSettingtotheP-9"WARNING" setpoint.
 
cpmPresschecksourceandverifythefollowing:
PT-17. 4: 4
Channeldigitaldisplayindicates greaterthanalarm,setpointaslistedinstep6.5.2.ChannelWarninglight(orange)illuminates.
 
6.5.5'ChannelAlarmlight(red)illuminates.
==6.0 INSTRUCTIONS==
6.5,.5.4MCBalarmE-11(ControlRoomHVACIsolation) annunciates.
NQTE  1:   Sections not to be performed  may be marked N/A if  not applicable.
6.5.5.5Outsideairinlet,exhaustreliefandtoiletexhaus:damperstraveltotheCLOSEDpositionasindicated bystatuslights.
NOTE  2:  Testing of radiation detectors may cause a spike on one of the LED readouts of the detectors. This is indicated by an illegible reading. The LED must be reset by momentarily interrupting power to that detector (turn power switch inside drawer to "OFF" position, then return to  "ON" ).
PT-17.4:8 6.5.5.6Charcoalfilter'fan starts.6.5.66.5.6.1'ResetControlRoomHVACSystemwhendigitaldisplaydecreases below"ALARM"setpointandverifythefollowing:
NOTE  3:  During the performance of this test, R-36, 37 or 38 may go into alarm due to system transient caused by testing. If this occurs, ensure the applicable channel is less than the alarm/warning setpoint, reset by depressing the applicable warning/alarm pushbutton, and reset control room ventilation if necessary.
Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatuslights.6.5.6.26.5.6.36.5.7Charcoalfilterfanisoff.MCBannunciator E-11alarmclears.IndeendentVerification Check:6.5.7.16.5.7'R-38Alarmsettostep6.5.2setting.R-38Warningsettingsettostep6.5.4setting.6.6RADIATION DETECTORFLOWSWITCH:6.6.16.6.26.6.2.16.6.2.2Securetheradiation monitorpump.Verifythefollowing:
NOTE  4: 'ny time monthly surveillance is performed, total charcoal filter fan run time must be a minimum of 15 minutes.
nLowFlownlightlit.PPCSPointFHVACD"C.R.HVACIsolation SystemFlow"inalarm.6.6.2'MCBalarmE-11(ControlRoomHVACIsolation) annunciates.
6.1    CHARCOAL FILTER FAN OPERATION:
6.6.2.4Outsideairinlet,exhaustreliefandtoiletexhas".damperstraveltotheCLOSEDpositionasindicated tystatuslights.6.6.2.5Charcoalfilterfanstarts.6.6.2.6Restartradiation monitorpump.6.6.2.7"LowFlow"lightextinguished.
6.3.. 1 Verify Control Room HVAC system is in accident mode or place system in "Accident Mode" by depressing Control Room Manual Isolation Pushbutton.
6.6.2.8VerifyPPCSPointFHVACD"C.R.HVACIsolation SysFlow"indicates normal.
6.1.2  Log time  that charcoal  filter fan  starts.
PT-17.4:9 6.6.2.9ResetControlRoomHVACSystemwhendigitaldisplaydecreases below"ALARM"setpointandverifythefollowing:
Time 6.1.3   After 15 minute run time, stop the charcoal filter fan by depressing the Control Room Isolation Reset Pushbutton.
6.6.2.9.1 Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatuslights.6.6.2.9.2 Charcoalfilterfanisoff.6.6.2.9.3 MCBannunciator E-11alarmclears.6.7TOXICANALYZERDEFEAT:6.7.16.7.26.7.3Placethelowflowtripbypassswitchto"BYPASS"position.
6.1.4  Log time  that charcoal  filter fan  stops.
SecuretherunningToxicGasAnalyzerSamplePump.(CirclepumprunningAorB.)Verify"LOWFLOW"lightsilluminate.
Time 6.2    List  P-9 "ALMQ4" setpoints in blanks provided.
6.86.8.1AMMONIADETECTOR:
R-36 [            cpm above  background]
RecordasfoundHVACAmmoniaAnalyzervalue.PPM6.8.2Turnthemanualthree-way valvefrom"SAMPLE""CALIBRATE" position.
R-37 [            cpm]
tothe'.8.36.8.4Turnthemanualthree-way valvefrom"ZERO"to"SPAN"position.
R-38 [            cpm above  background]
Usingabottledgas,adjusttheflowonthebottleregulator toslowlyincreasegasconcentration asreadonthedetector.
 
6.8.5RecordthepointatwhichtheAmmoniaAlarmlights:2illuminate andactuatetheControlRoomventilati recircmode.ACB¹94-324BasisforLimit/Value AACCEPTANCE CRITERIA:
PT-17.4:5 6.2.1    List  P-9 "WARNING"    setpoints in blanks provided.
10PPM21PPM 6.8.66.8.6.1Verifythefollowing whenthedigitaldisplayontheAmmoniadetectorreaches10ppm:MCBAlarmE-11(ControlRoomHVACIsolation) annun-ciates.6.8.6.2Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheCLOSED'position asindicated bystatuslights.6.8.6.3Charcoalfilterfanstarts.6.8.6.4.ShutoffAmmoniabottleandbleedpressureoffthebottleandregulator.
R-36 [              cpm above  background]
6.8.6.56.8.6.6Turnthemanualthree-way valvefrom"SPAN"tothe"ZERO"gasposition.
R-37 [              cpm]
Turnthemanualthreewayvalvefrom"Calibrate" toSample.6.8.6.7Recordammoniadetectordisplaywhenstable.PPM6.8.6.7.1'erify ammoniadetectordisplayis~1PPMfromtheasfoundvalueinStep6.8.1.Ifnot,performStep6.8.6.8inclusive, topurgetheammoniadetector.
R-38 [              cpm above  background]
6.8.6.8Performthefollowing to.purgetheAmmoniadetector.
'6.3     R-36 NOBLE    GAS MONITOR 6.3.1    At R-36 monitor drawer, record '!as found" Alarm setting.
N/AStep6.8.6'.1and6.8.6.8.2 ifpurgeisnotrequired.
cpm 6.3.2    Set R-36 Alarm    setting to the    P-9 "ALARM"  setpoint.
6.8.6.8.1 RestarttheToxicGasMonitorpumpthatwasrunninginstep6.7.2.6.8.6.8.2 WhentheAmmoniadetectordigitaldisplayindicates astablevaluez1.0ppmfromtheasfoundvalueinStep6.8.1,thensecuretherunningtoxicgasmonitorpump.6.8.6.9ResetControlRoomHVACsystemandverifythefollowi.-.q 6.8.6.9.1 Outsideairinlet,exhaustreliefandtoiletexhausdamperstraveltotheOPENpositionasindicated statuslights.
cpm 6.3.3   .At R-36      monitor drawer,      record  "as  found"   Warning setting.
PT-17.4:11 6.8.6.9.2 Charcoalfilterfanisoff.6.8.6.9.3 M.C.B.Annunciator E-11alarmclears.6.8.6.8.6.X.OIndeendentV'erification Check:6.10.1ManualThree-Way Valve"Sample" Position6.8.6.10.2 6.8.6'1ManualThree-Way Valve"Zero"PositionIIftestisbeingperformed following calibration and/ormaintenance oftheAmmoniadetectoronlyandiscomplete, continueonwiththeToxicDetectorReinstate sectionofthisprocedure, otherwise markthisstepN/A.6.9CHLORINEDETECTOR-BOTTLECALIBRATION TESTGAS:6.9.1RecordasfoundHVACchlorineanalyzervalue.PPM6.9.2Turnthemanualthree-way valvefrom"SAMPLE"tothe"CALIBRATE" position.
cpm 6.3.4    Set R-36 Warning Setting to the P-9          "WARNING"   setpoint.
6.9.3Turnthemanualthree-way valvefrom"ZERO"to"SPAN"position.
cpm 6 '.5    Press check source and      verify the following:
~6.9.4Usingabottledgas,adjusttheflowonthebottleregulator toslowlyincreasegasconcentration asreadonthedetector.
6.3.5.1  Channel  .digital display indicates greater        than  "ALARM" setpoint as listed in step 6.3.2.
6.9.5RecordthepointatwhichtheChlorineDigitalDisplayactuatestheControlRoomventilation recircmode~PPMACB094-325BasisforLimit/Value AACCEPTANCE CRITERIA:
6.3.5.2  Channel Warning    light (orange) illuminates.
1PPM2.20PPM6.9.6Verifythefollowing whenthedigitaldisplayonChlorineDetectorreaches1ppm:6.9.6.1MCBAlarmE-11(ControlRoomHVACIsolation) annunciate-6.9.6.2Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheCLOSEDpositionasindicated bystatuslights.6.9.6.3Charcoalfilterfanstarts.6.9.6.4ShutoffChlorinebottleandbleedpressureoffthebottleandregulator.
6.3.5.3 Channel Alarm    light (red) illuminates.
6.9.6.5Turnthemanualthree-way valvefrom"SPAN"tothe"ZERO"gasposition.
6.3.5.4  MCB  alarm E-11      (Control    Room  HVAC  Isolation) annun-ciates.
6.9.6.6Turnthemanualthreewayvalvefrom."Calibrate" toSample.6.9'.6.7Recordchlorinedetectordisplaywhenstable.PPM6.9.6.7.1 Verifychlorinedetectordisplayisg.2ppmfromtheasfound'value inStep6.9.1.Ifnot,performStep6.9.6.8inclusive topurgethechlorinedetector.
6.3.5.5  Outside    air inlet,    exhaust    relief  and  toilet  exhaust dampers    travel to the .closed position        as  'indicated by status lights.
6.9.6.8Performthefollowing topurgetheChlorinedetector.
6.3.5.6  Charcoal    filter fan    starts.
N/Astep6.9.6.8.1 and6.9.6.8.2 ifpurgeisnotrequired.
6.3.5.7  Recirc dampers      AKD07 and    AKD09 open    (in Air Handli.".g Room)  .
6.9.6.8.1 RestarttheToxicGasMonitorpumpthatwasrunninginstep6.7.2.6.9.6.8.2 WhentheChlorinedetectordigitaldisplayindicates astablevalueg.2ppmoftheasfoundvalueinStep6.9.1.Thensecuretherunningtoxicgasmonitorpump.6.9.6.9ResetControlRoomHVACsystemandverifythefollowing:
6.3.6    Reset Control Room HVAC System when digital display decreases      below "ALARM" setpoint and verify t!;e following:
6.9.6.9.1 Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatuslights'.9.6.9.2 CharcoalFilterFanisoff.6.9.6.9.3 M.C.B.Annunciator E-llAlarmclears.
6.3.6.1  Outside    air inlet,     exhaust relief and toilet exhaus dampers travel to        the OPEN position as indicated ."y status lights.
PT-17.4:13 6.9.6.10IndeendentVerification Check:6.9.6.10.1 ManualThree-Way Valve"Sample" Position6.9.6.10.2 6.9.6.11ManualThree-Way Valve"Zero"PositionIftestisbeingperformed following calibration and/ormaintenance ofthechlorinedetectoronlyandiscomplete, continueonwiththeToxicAnalzerReinstate sectionofthisprocedure, otherwise markthisstepN/A.6.10CHLORINEDETECTOR-CHLORINEMASTCALIBRATION UNIT:6.10.1RecordasfoundHVACchlorineanalyzervalue.PPM6.10.2Turnthemanualthree-way valvefrom"SAMPLE"tothe"CALIBRATE" position.
 
6.10.3Turnthemanualthree-way valvefrom"ZERO"to"SPAN"position.
PT-17.4:6 6.3.6.1.1 Recirc  dampers  AKD07 and AKD09      close  (in Air Handling Room)  .
6.10.4ConnectMastCalibration Unittotestconnection asfollows:6.10.4.1Closethe'alves onthelowerinletsideandupperoutletsideofthechlorineprobeflowtube.6.10.4.2RemovetheSwagelokplugsfromboththeinletandoutlettesttees.6.10.4.3ConnecttheoutputtubingfromtheMASTcalibration uni"totheupperoutlettesttee.NOTE:Thisisthe"backflow" methodpreferred byANACONtoavoidprobetipsaturation.
6.3.6.2   Charcoal  filter fan  is off.
6.10.5PullgasselectvalveontheMastCalibration Unitinjectgas.6.10.6RecordthepointatwhichtheChlorinedigitaldisp'.s,actuatestheControlRoomventilation recircmode.ACB¹94-325BasisforLimit/Value AACCEPTANCE CRITERIA:
6.3.6.3  MCB  annunciator E-11 clears.
1PPM+.20ppm PT-17.4:14 6.10.76.10.7.1Verifythefollowing whenthedigitaldisplayontheChlorineDetectorreaches1ppm:MCBalarmE-11(ControlRoomHVACIsolation) annun-ciates.6.10.7.2Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheCLOSEDpositionasindicated bystatuslights.6.10.7.3Charcoalfilterfanstarts.6.10.8RemovetheMASTcalibration unitasfollows:6.10.8.1Disconnect theMASTcalibration Unitfromthetesttee.6.10'.2Openthelowerinletvalveandupperoutletvalveofthechlorineprobeflowtube.VerifiedBy:6.10.8.3InstalltheSwagelokplugsinboththeinletandoutlettesttees.VerifiedBy:6.10.9Turnthemanualthree-way valvefrom"SPAN"tothe"ZERO"gasposition.
6.3.7    Inde endent  Verification    Check:
6.10.10Turnthemanualthree-way valvefrom"CALIBRATE" to"SAMPLE".
6.3.7 '  R-36 Alarm set    to step 6.3.2 setting.
6.10.11Recordchlorinedetectordisplaywhenstable.6.10.11.1 Verifychlorinedetectordisplayisz.2ppmfromthe.sfoundvalueinStep6.10.1.Ifnot,performStep6.10.:.inclusive topurgethechlorinedetector.
6.3 '.2  R-36 Warning setting set to step 6.3.4 setting.
6.10.12Performthefollowing topurgetheChlorinedetect.:N/Astep6.10.12.1 and6.10.12.2 ifpurgeisrequired.
6.4       R-37 PARTICULATE MONITOR 6 '.1    At R-37 monitor drawer, record "as found" Alarm setting.
PT-17.4:15 6.10.12.1 RestarttheToxicGasMonitorpumpthatwasrunninginstep6.7.2.6.10.12.2 WhentheChlorinedetectordigitaldisplayindicates astablevalueg.2ppmoftheasfoundvalueinStep6.10.1,thensecuretherunningToxicGasMonitorPump.6.10.13ResettheControlRoomHVACsystemandverifythefollowing:
cpm 6.4.2    Set R-37 Alarm    setting to the      P-9 "ALARM"  setpoint.
6.10.13.1 Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatuslights.6.10.13.2 Charcoalfilterfanis"OFF".6.10.13.3 MCBannunciator E-11Alarmclears.6.10.14IndeenentVerification Check:6.10.14.1 ManualThree-way Valve.6.10.14.2 ManualThree-way Valve."SAMPLE"position"ZERO"position6.10.15Iftestisbeingperformed following calibration and/ormaintenance oftheChlorineDetectorandiscomplete, continueonwiththeToxicDetectorReinstate sectionofthisprocedure, otherwise markthisstepN/A.6.116.11.16.11.1'AMMONIADETECTORFLOWSWITCH:RestarttheToxicGas'MonitorPumpthatwasrunninginstep6.7.2(circleAorBtorun)PlacetheToxicGasDetectorLowFlowBypassSwitch"NORMAL"position.
i cpm 6.4.3    At R-37 monitor drawer,        record    "as  found"  "WARNING" setting.
6.11.1.2Reducetheflowthroughammoniadetectortoc2.0SCFM.6.11.26.11.2.16.11.2.2Verifythefollowing:
cpm 6.4.4    Set R-37 "WARNING" setting to the P-9        "WARNING"  setpoint.
"Low.Flow"lightlit.PPCSPointFHVACD'C.R.HVACIsolation SystemFlow'larm.
cpm 6.4.5    Press check source and    verify the following:
PT-17.4:16 6.11.2.3MCBalarmE-11(ControlRoomHVACIsolation) annunciates.
6.4.5.1  Channel  digital display indicates greater          than  "ALARM" setpoint as listed in Step 6.4.2.
6.11'.4Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheCLOSEDpositionasindicated bystatuslight@.6.11.2.5Charcoalfilterfanstarts.6.11.2.6Increaseflowto>2.25SCFM.6.11.2.7Verify"LowFlow"lightextinguished.
6.4.5.2  Channel Warning    light (orange) illuminates.
6.11.2.8VerifyPPCSPointFHVACD"C.R.HVACIsolation SystemFlo'w"indicates normal.6.11.2.9ResetControlRoomHVACSystem.6.11.2.10 Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatuslights.6.11.2.11 Charcoalfilterfanisoff.6.11.2.12 MCBannunciator E-11alarmclears.6.12CHLORINEMONITORFLOWSWITCH:6.12.1AorBGasMonitorPumpRunning.(CircleRunning)6.12.1.1Verifyand/orplacetheToxicGasDetectorBypassSwitchin"NORMAL"position.
6.4.5.3  Channel Alarm    light (red) illuminates.
6.12.1,2Reducetheflowthroughthechlorinemonitorto<0.25SCFM.6.12.2Verifythefollowing:
6.4.5.4  MCB  alarm E-11 (Control  Room HVAC    Isolation) annunciates.
6.12.2.1Lowflowlightlit.'.12.2.2 PPCSControlRoomlowflowalarm.6.12.2.3MCBalarmE-11(ControlRoomHVACIsolation) annunciates.
6.4.5.5  Outside  air inlet, exhaust relief and toilet exhaus.
PT-17.4:17 6.12.2.4Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheCLOSEDpositionasindicated bystatuslights.6.12.2.5Charcoalfilterfanstarts.6.12.2.6Increaseflowto0.25SCFMorgreater.6.12.2.7Verify"LowFlow"lightextinguished.
dampers travel to the CLOSED position as indicated hy status lights.
6.12.2.8VerifyPPCSPointFHVACD"C.R.HVACIsolation SystemFlow"indicates normal.6.12.2.9ResetControlRoomHVACSystemandverifythefollowing:
6.4.5.6   Charcoal  filter fan  starts.
6.12.2.9.1 6'2.2.9.2Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheOPENpositionasindicated bystatus,lights.Charcoalfilterfanisoff.MCBannunciator E-11alarmclears.CONTROLROOMMANUALRECIRCULATION ACTUATION:
 
6.12.2.9.3 6.136.13.1Depressthe"ControlRoomManualRecirculation" pushbutton.
PT-17.4:7 6.4.6    Reset Control Room HVAC System when digital display decreases below "ALARM" setpoint and verify the follow-ing:
6.13.26.13.3Verifythefollowing:
6.4.6.1  Outside  air inlet,   exhaust relief and toilet exhaust dampers  travel to    the OPEN position as indicated by status lights.
MCBalarmE-11(ControlRoomHVACIsolation) annun-ciates.6.13.46.13.56.13.6Outsideairinlet,exhaustreliefandtoiletexhaustdamperstraveltotheCLOSEDpositionasindicated bystatuslights.Charcoalfilterfanstarts.ResetControlRoomHVACSystemandverifythefollowing:
6.4 '.2  Charcoal  filter fan  is off.
6.13.6.1Outsideairinlet,exhaustreliefandtoiletexhaust,damperstraveltotheOPENpositionasindicated bystatuslights.6.13.6.2Charcoalfilterfanisoff.
6.4.6.3  MCB  annunciator  E-ll  alarm clears.
PT-17.4:18 6.13.6.3MCBannunciator E-11alarmclears.6.14TOXICDETECTORREINSTATE:
6.4.7    Independent  Verification    Check:
6.14.1Startorensurerunningthesamplepumpthatwassecuredinstep6.7.2andverifyproperflowrates:Ammonia>2.25scfmChlorine>0.25scfm6.14.2Verifytoxicgasammonia"LowFlow"lightextinguished.
6.4.7.1  R-37 Alarm  to Step 6.4.2 setting.
6'4.3Verifytoxicgaschlorine"LowFlow"lightextinguished.
6.4.7.2  R-37 "WARNING" setting set to Step 6.4.4 setting.
6.14.4Verify'he lowflowbypassswitchisin'NORMAL" position.
6.5     R-38 IODINE MONITOR:
6.156.15.16.15.2IndeendentVerification Check:PT-17.4:19 Verifysamplepumpon.MarkthepumpthatisnotrunningN/A."A"Running"B"RunningToxicGasMonitorLowFlowBypassSwitchinthe"Normal"Position.
6.5.1    At R-38      monitor  drawer,    record    "as    found"  Alarm setting.                                           cpm 6 '.2    Set R-38 Alarm    setting to the    P-9 "AIAfQI" setpoint.
6.16LogtotalruntimeonMCB"ControlRoomHVACSystemCharcoalFilterIn-Service Log".6.17NotifyHeadControlOperatorthattestiscomplete.
cpm 6.5.3    At R-38 monitor drawer,          record    "as    found"  Warning setting.
cpm 6.5.4    Set R-38 Warning Setting to the P-9 "WARNING" setpoint.
cpm 6.5.5    Press check source and      verify the following:
6.5.5.1  Channel  digital display indicates greater            than alarm, setpoint  as listed in step 6.5.2.
6.5.5.2  Channel  Warning light (orange) illuminates.
6.5.5 '  Channel  Alarm light (red) illuminates.
6.5,.5.4 MCB  alarm E-11 (Control    Room HVAC  Isolation) annunciates.
6.5.5.5  Outside  air inlet,    exhaust    relief  and    toilet  exhaus:
dampers  travel to the    CLOSED  position    as  indicated  by status lights.
 
PT-17.4:8 6.5.5.6 Charcoal  filter'fan starts.
6.5.6   'Reset Control Room HVAC System when digital display decreases    below "ALARM" setpoint and verify the following:
6.5.6.1  Outside  air inlet,    exhaust relief and toilet exhaust dampers  travel to    the OPEN position as indicated by status lights.
6.5.6.2 Charcoal  filter fan  is off.
6.5.6.3  MCB  annunciator E-11 alarm clears.
6.5.7    Inde endent    Verification  Check:
6.5.7.R-38 Alarm set    to step 6.5.2 setting.
6.5.7 '  R-38 Warning setting set to step 6.5.4 setting.
6.6      RADIATION DETECTOR FLOW SWITCH:
6.6.1   Secure the  radiation monitor    pump.
6.6.2   Verify the following:
6.6.2.1  n Low Flown  light  lit.
6.6.2.2  PPCS  Point  FHVACD  "C.R. HVAC  Isolation  System Flow" in alarm.
6.6.2 '  MCB  alarm E-11 (Control    Room HVAC  Isolation) annunciates.
6.6.2.4  Outside  air inlet,    exhaust relief and toilet exha s".
dampers  travel  to the CLOSED position as indicated ty status lights.
6.6.2.5  Charcoal  filter fan  starts.
6.6.2.6  Restart radiation monitor pump.
6.6.2.7  "Low Flow" light extinguished.
6.6.2.8 Verify PPCS Point FHVACD "C.R.         HVAC  Isolation  Sys Flow" indicates normal.
 
PT-17.4:9 6.6.2.9  Reset Control Room HVAC System when digital display decreases      below "ALARM" setpoint and verify the following:
6.6.2.9.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.
6.6.2.9.2 Charcoal filter fan is off.
6.6.2.9.3 MCB annunciator E-11 alarm clears.
6.7       TOXIC ANALYZER DEFEAT:
6.7. 1   Place  the    low flow    trip    bypass  switch to      "BYPASS" position.
6.7.2    Secure    the running Toxic Gas          Analyzer Sample      Pump.
(Circle  pump running A or B.)
6.7.3    Verify  "LOW FLOW"  lights illuminate.
6.8       AMMONIA DETECTOR:
6.8.1    Record as found    HVAC Ammonia    Analyzer value.
PPM 6.8.2    Turn the manual three-way valve from "SAMPLE" to the "CALIBRATE" position.
Turn the manual three-way valve from "ZERO" to "SPAN"
                                                                              '.8.3 position.
6.8.4    Using a bottled gas, adjust the flow on the bottle regulator to slowly increase gas concentration as read on the detector.
6.8.5    Record the    point at which the      Ammonia Alarm  lights :2 illuminate and actuate          the Control    Room  ventilati recirc mode.
ACB  &#xb9;            Basis for        ACCEPTANCE CRITERIA:
Limit/Value 10 PPM 2 1 PPM 94-324                A
 
6.8.6       Verify the following      when the digital display on the Ammonia  detector reaches 10 ppm:
6.8.6.1     MCB Alarm E-11      (Control Room HVAC Isolation) annun-ciates.
6.8.6.2     Outside  air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED 'position as indicated by status lights.
6.8.6.3     Charcoal  filter fan  starts.
6.8.6.4    .Shut off Ammonia  bottle and bleed pressure off the bottle and regulator.
6.8.6.5    Turn the manual three-way valve from "SPAN" to the "ZERO" gas  position.
6.8.6.6    Turn the manual      three  way valve from "Calibrate" to Sample.
: 6. 8. 6. 7  Record ammonia detector display when stable.
PPM 6.8.6.7.1'erify    ammonia  detector display is ~ 1 PPM from the as found value  in Step 6.8.1. If not, perform Step 6.8.6.8 inclusive, to purge the ammonia detector.
6.8.6.8    Perform the following to.purge the Ammonia detector. N/A Step 6.8.6 '.1  and 6.8.6.8.2    if purge is not required.
6.8.6.8.1 Restart the Toxic      Gas  Monitor pump  that was running in step 6.7.2.
6.8.6.8.2  When  the Ammonia detector digital display indicates a stable value z 1.0 ppm from the as found value in Step 6.8.1, then secure the running toxic gas monitor pump.
6.8.6.9    Reset Control Room HVAC system and verify the followi.-.q 6.8.6.9.1 Outside air inlet, exhaust relief and toilet exhaus dampers travel to the OPEN position as indicated status lights.
 
PT-17.4:11 6.8.6.9.2 Charcoal filter fan is off.
6.8.6.9.3 M.C.B. Annunciator E-11 alarm clears.
6.8. 6.X.O Inde endent V'erification Check:
6.8. 6.10.1       Manual Three-Way Valve"Sample" Position 6.8.6.10.2       Manual Three-Way Valve "Zero" Position      I 6.8.6 '1 maintenance If test is being    performed following calibration and/or of the Ammonia detector only and is complete, continue on with the Toxic Detector Reinstate section of this procedure, otherwise mark this step N/A.
6.9         CHLORINE DETECTOR      BOTTLE CALIBRATION TEST GAS:
6.9.1       Record as found    HVAC  chlorine analyzer value.
PPM 6.9.2       Turn the manual    three-way valve from          "SAMPLE"  to the "CALIBRATE" position.
6.9.3       Turn the manual three-way valve from            "ZERO"  to  "SPAN" position. ~
6.9.4      Using a bottled gas, adjust the flow on the bottle regulator to slowly increase gas concentration as read on the detector.
6.9.5      Record the    point at which the Chlorine Digital Display actuates the Control    Room ventilation recirc mode        ~
PPM ACB 0            Basis for        ACCEPTANCE CRITERIA:
Limit/Value 1 PPM  2 .20 PPM 94-325              A 6.9.6       Verify the following      when    the  digital display    on Chlorine Detector reaches 1        ppm:
6.9.6.1    MCB Alarm E-11 (Control Room      HVAC  Isolation) annunciate-
 
6.9.6.2  Outside                air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED position as indicated by status lights.
6.9.6.3  Charcoal                filter fan  starts.
6.9.6.4  Shut off Chlorine bottle                      and bleed  pressure  off  the bottle and regulator.
6.9.6.5  Turn the manual three-way valve from "SPAN" to the "ZERO" gas  position.
6.9.6.6  Turn the manual                  three  way  valve from. "Calibrate" to Sample.
6.9'.6.7  Record chlorine detector display when stable.
PPM 6.9.6.7.1 Verify chlorine detector display is g .2 ppm from the as found'value in Step 6.9.1. If not, perform Step 6.9.6.8 inclusive to purge the chlorine detector.
6.9.6.8  Perform the following to purge the Chlorine detector.
N/A step required.
6.9.6.8.1 and 6.9.6.8.2        if  purge is not 6.9.6.8.1 Restart the Toxic                  Gas  Monitor  pump  that  was  running in step 6.7.2.
6.9.6.8.2 When  the Chlorine detector digital display indicates a stable value g .2 ppm of the as found value in Step 6.9.1. Then secure the running toxic gas monitor pump.
6.9.6.9  Reset Control Room                  HVAC system and    verify the following:
6.9.6.9.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights'.9.6.9.2 Charcoal                Filter Fan  is off.
6.9.6.9.3 M.C.B. Annunciator E-ll Alarm clears.
 
PT-17.4:13 6.9.6.10 Inde endent Verification Check:
6.9.6.10.1       Manual Three-Way Valve"Sample" Position 6.9.6.10.2       Manual Three-Way Valve "Zero" Position 6.9.6.11 If test is being performed following calibration and/or maintenance of the chlorine detector only and is complete, continue on with the Toxic Anal zer Reinstate section of this procedure, otherwise mark this step N/A.
6.10       CHLORINE DETECTOR      CHLORINE MAST CALIBRATION UNIT:
6.10.1     Record as found    HVAC  chlorine analyzer value.
PPM 6.10.2     Turn the manual three-way valve from "SAMPLE" to the "CALIBRATE"     position.
6.10.3     Turn the manual three-way valve from "ZERO" to "SPAN" position.
6.10.4    Connect  Mast    Calibration Unit to test connection          as follows:
6.10.4.1   Close  the'alves on the lower inlet side and upper outlet side of the chlorine probe flow tube.
6.10.4.2   Remove  the Swagelok plugs from both the      inlet  and  outlet test tees.
6.10.4.3  Connect the output tubing from the        MAST calibration uni" to the upper outlet test tee.
NOTE:      This  is  the "backflow" method preferred        by ANACON    to avoid probe tip saturation.
6.10.5    Pull  gas  select valve    on the Mast    Calibration Unit inject  gas.
6.10.6    Record the    point at which the Chlorine digital disp'.       s, actuates the Control      Room  ventilation recirc  mode.
ACB  &#xb9;            Basis for      ACCEPTANCE CRITERIA:
Limit/Value 1 PPM + .20 ppm 94-325                A
 
PT-17.4:14 6.10.7    Verify the following      when    the  digital display    on the Chlorine Detector reaches        1 ppm:
6.10.7.1  MCB alarm E-11       (Control    Room  HVAC  Isolation) annun-ciates.
6.10.7.2 Outside    air inlet,    exhaust relief and toilet exhaust dampers  travel  to the CLOSED position as indicated by status lights.
6.10.7.3  Charcoal    filter fan  starts.
6.10.8    Remove the MAST calibration unit as follows:
6.10.8.1  Disconnect the MAST calibration Unit from the test tee.
6.10 '.2  Open  the lower inlet valve and upper outlet valve of the chlorine probe flow tube.
Verified  By:
6.10.8.3  Install  the Swagelok plugs      in both the inlet    and  outlet test tees.
Verified  By:
6.10.9    Turn the manual three-way valve from "SPAN" to the "ZERO" gas  position.
6.10.10  Turn the manual      three-way valve from "CALIBRATE" to "SAMPLE".
6.10.11   Record  chlorine detector display      when  stable.
6.10.11.1 Verify chlorine detector display is z .2 ppm from the .s found value in Step 6.10.1. If not, perform Step 6.10.:.
inclusive to purge the chlorine detector.
6.10.12   Perform the following to purge the Chlorine detect.:
N/A step required.
6.10.12.1 and 6.10.12.2        if  purge is
 
PT-17.4:15 6.10.12.1 Restart the Toxic      Gas  Monitor  pump  that  was  running in step 6.7.2.
6.10.12.2 When  the Chlorine detector digital display indicates a stable value g .2 ppm of the as found value in Step 6.10.1, then secure the running Toxic Gas Monitor Pump.
6.10.13  Reset    the Control      Room  HVAC  system    and  verify          the following:
6.10.13.1 Outside    air inlet,   exhaust relief and toilet exhaust dampers    travel to    the OPEN position as indicated by status lights.
6.10.13.2 Charcoal    filter fan  is  "OFF".
6.10.13.3 MCB  annunciator E-11 Alarm clears.
6.10.14  Inde en ent Verification Check:
6.10.14.1 Manual Three-way Valve.           "SAMPLE" position 6.10.14.2 Manual Three-way Valve.               "ZERO" position 6.10.15  If test maintenance is being performed following calibration and/or of the Chlorine Detector and is complete, continue on with the Toxic Detector Reinstate section of this procedure, otherwise mark this step N/A.
6.11      AMMONIA DETECTOR FLOW SWITCH:
6.11.1    Restart the Toxic Gas 'Monitor Pump that was running in step 6.7.2 (circle A or B to run) 6.11.1  ' Place the Toxic Gas Detector Low Flow Bypass Switch "NORMAL"     position.
: 6. 11.1.2 Reduce the    flow through    ammonia  detector to    c  2.0        SCFM.
6.11.2    Verify the following:
6.11.2.1  "Low. Flow"  light  lit.
6.11.2.2  PPCS  Point  FHVACD  'C.R. HVAC Isolation    System  Flow'larm.
 
PT-17.4:16 6.11.2.3  MCB  alarm E-11 (Control              Room HVAC  Isolation) annunciates.
6.11 '.4  Outside dampers air inlet, travel to the exhaust CLOSED relief  and position toilet as exhaust indicated by status light@.
6.11.2.5  Charcoal    filter fan            starts.
6.11.2.6 Increase flow to              >  2.25  SCFM.
6.11.2.7  Verify  "Low Flow"             light extinguished.
6.11.2.8  Verify    PPCS  Point FHVACD "C.R.                 HVAC  Isolation  System Flo'w" indicates normal.
6.11.2.9 Reset Control Room HVAC System.
6.11.2.10 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.
6.11.2.11 Charcoal filter fan is off.
6.11.2.12 MCB annunciator E-11 alarm clears.
6.12      CHLORINE MONITOR FLOW SWITCH:
6.12.1    A or  B Gas  Monitor            Pump  Running.    (Circle Running) 6.12.1.1  Verify and/or place the Toxic                  Gas  Detector Bypass Switch in "NORMAL" position.
6.12.1,2  Reduce  the flow through the chlorine monitor to <0.25 SCFM.
6.12.2    Verify the following:
6.12.2.1  Low  flow light PPCS Control Room low flow alarm.
lit.'.12.2.2 6.12.2.3  MCB alarm E-11 (Control Room HVAC Isolation) annunciates.
 
PT-17.4:17 6.12.2.4  Outside  air inlet,    exhaust    relief  and  toilet  exhaust dampers  travel to the      CLOSED  position  as  indicated by status lights.
6.12.2.5  Charcoal  filter fan    starts.
6.12.2.6  Increase flow to 0.25      SCFM  or greater.
6.12.2.7  Verify  "Low  Flow" light extinguished.
6.12.2.8  Verify  PPCS  Point  FHVACD    "C.R. HVAC  Isolation  System Flow" indicates normal.
6.12.2.9  Reset Control    Room HVAC    System and  verify the following:
6.12.2.9.1      Outside    air inlet,      exhaust  relief    and  toilet exhaust    dampers    travel to the      OPEN  position  as indicated by status, lights.
6 '2.2.9.2      Charcoal    filter fan    is off.
6.12.2.9.3      MCB  annunciator E-11 alarm clears.
6.13      CONTROL ROOM MANUAL RECIRCULATION ACTUATION:
6.13.1    Depress    the    "Control      Room    Manual    Recirculation" pushbutton.
6.13.2    Verify the following:
6.13.3    MCB  alarm E-11      (Control    Room  HVAC  Isolation) annun-ciates.
: 6. 13.4    Outside  air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED position as indicated by status lights.
6.13.5    Charcoal  filter fan    starts.
6.13.6    Reset Control    Room HVAC    System and  verify the following:
6.13.6.1  Outside  air inlet,      exhaust relief and toilet exhaust, dampers travel to      the OPEN position as indicated by status lights.
6.13.6.2  Charcoal  filter fan    is off.
 
PT-17.4:18 6.13.6.3 MCB annunciator E-11 alarm clears.
6.14    TOXIC DETECTOR REINSTATE:
6.14.1  Start or ensure running the sample pump that    was secured in step 6.7.2 and verify proper flow rates:
Ammonia  > 2.25 scfm Chlorine  > 0.25 scfm 6.14.2  Verify toxic  gas ammonia "Low Flow"  light extinguished.
6 '4.3  Verify toxic gas  chlorine "Low Flow"  light extinguished.
6.14.4  Verify'he    low flow bypass      switch is in'NORMAL" position.
 
PT-17.4:19 6.15        Inde endent  Verification  Check:
6.15.1      Verify sample  pump on. Mark the pump  that is not running N/A.
                                                "A" Running "B" Running 6.15.2      Toxic  Gas Monitor  Low Flow Bypass  Switch in the "Normal" Position.
6.16        Log  total run time on MCB "Control        Room HVAC  System Charcoal  Filter In-Service Log".
6.17      Notify Head Control Operator that test is complete.
COMMENTS:
COMMENTS:
COMPLETED BY:DATECOMPLETED:
COMPLETED BY:
HEADCONTROLOPERATOR:
DATE COMPLETED:
SHIFTSUPERVISOR:
HEAD CONTROL OPERATOR:
RESULTSANDTESTREVIEW:DATE:}}
SHIFT SUPERVISOR:
RESULTS AND TEST REVIEW:                           DATE:}}

Latest revision as of 10:27, 4 February 2020

Rev 31 to Procedure PT-17.4, Control Room Radiation R-36, R-37,R-38 & Toxic Gas Monitor Operability Test.
ML17264A204
Person / Time
Site: Ginna Constellation icon.png
Issue date: 03/22/1995
From: Marlow T
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17264A201 List:
References
PT-17.4, NUDOCS 9510260343
Download: ML17264A204 (20)


Text

ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION (0 CONTROLLED COPY NUMBER PROCEDURE NO. PT-17.4 CONTROL ROOM RADIATION R-36 R-37 R-38 AND TOXIC GAS MONITOR OPERABILITY TEST TECHNICAL REVIEW PORC REVIEW DATE (0 PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

GINNA STATION THIS PROCEDURE CONTAINS 19 START:

PAGES DATE TIME COMPLETED:

DATE TIME'510260343 951018 PDR ADOCK 05000244 p PDR

PT-17.4:1 PT-17.4 CONTROL ROOM RADIATION R-36 R-37 R-38 AND TOXIC GAS MONITOR OPERABILITY TEST

1.0 PURPOSE

To describe the steps necessary to verify the operability of the Control Room particulate, Iodine and Noble Gas radiation monitors.

1.2 To describe the steps necessary to verify the operability of the Ammonia and Chlorine detectors.

2.0 TEST RE UIREMENTS:

2. Particulate, Iodine and Noble Gas radiation detectors j.'.2 alarm and automatic actions take place as specified.

Ammonia and Chlorine detectors alarm and automatic actions take place as specified.

2.3 Radiation detector response to installed check source is veri fied.

2.4 Ammonia and Chlorine detectors respond to span gases.

2.5 Radiation monitor and toxic gas detector flow switches actuate and automatic actions take place as specified.

2.6 Completion of System/Equipment Independent Verification Che'ck.

3.0 REFERENCES

3.1 Plant Technical Specifications 4.5.2.3.9, 3.5.6 and Tab'e 4.1-1.

3.2 NRC Operation and Maintenance Manual.

3.3 Foxboro Operation and Maintenance Manual.

3.4 Independent Verification Procedure, A-1408.

3.5 Results and Test Acceptance Criteria Basis (ACB) File.

PT-17.4:2 3.5.1 Key: Basis for Limits/Values V Vendor E - Engineering A Administrative C - Code T - Tech Spec 4.0 INITIAL CONDITIONS:

4.1 Plant in any mode of operation.

4.2 Notify Shift Supervisor at start of test.

4.3 Notify HCO at start of test.

4.4 Notify QC Dept. at start of test.

4.5,'est personnel are qualified in accordance with A-1102.

4.6 Prior to performing operability test of the chlorine detector, determine which section will be used, and mark the other N/A.

4.6.1 Chlorine bottle calibration test gas (Section 6.9).

4.6.2 Chlorine mast calibration unit (Section 6.10).

NOTE: The Tech. Spec. channel functional test power failure requirement is satisfied during the successful performance of each individual channel, high alarm/trip setpoint check.

4.7 If the setpoint for a radiation detector alarm and/or trip is found to be higher than required, notify Shift Supervisor and take one of the following actions immediately'.

1) The setpoint shall be immediately corrected without declaring the channel inoperable; or
2) Declare the channel inoperable.

4.8 The individual performing the independent verification shall be a person knowledgeable in the appropriate system involved, normally an Auxiliary Operator or Licensees Operator (active or inactive).

PT-17. 4: 3 4.8.1 The initial realignment steps may be performed at various points throughout the procedure, however, the Independent Verification Check shall be performed upon completion of testing each individual train prior to proceeding to any other train.

4 8.2 Due to the frequent tripping/resetting of the Control Ventilation System, the total charcoal run time

~

Room logged on T-31.10, Attachment 1, shall be from initial trip or time initially placed in the recirc mode, to time of final reset.

4.9 If PPCS is inoperable, N/A steps verifying PPCS response.

5.0 PRECAUTIONS

5.1 Observe normal company safety practices.

5.2 Any deviations from stated limits in this procedure should be noted under comments and a WR/TR initiated when applicable.

5.3 Prior to opening Ammonia or Chlorine bottle, verify regulators are back-seated and bottles piped to detectors.

5' Care should be taken when handling Ammonia ( 60 ppm) and Chlorine bottles ( 3.0 ppm) since these are toxic substances.

PT-17. 4: 4

6.0 INSTRUCTIONS

NQTE 1: Sections not to be performed may be marked N/A if not applicable.

NOTE 2: Testing of radiation detectors may cause a spike on one of the LED readouts of the detectors. This is indicated by an illegible reading. The LED must be reset by momentarily interrupting power to that detector (turn power switch inside drawer to "OFF" position, then return to "ON" ).

NOTE 3: During the performance of this test, R-36, 37 or 38 may go into alarm due to system transient caused by testing. If this occurs, ensure the applicable channel is less than the alarm/warning setpoint, reset by depressing the applicable warning/alarm pushbutton, and reset control room ventilation if necessary.

NOTE 4: 'ny time monthly surveillance is performed, total charcoal filter fan run time must be a minimum of 15 minutes.

6.1 CHARCOAL FILTER FAN OPERATION:

6.3.. 1 Verify Control Room HVAC system is in accident mode or place system in "Accident Mode" by depressing Control Room Manual Isolation Pushbutton.

6.1.2 Log time that charcoal filter fan starts.

Time 6.1.3 After 15 minute run time, stop the charcoal filter fan by depressing the Control Room Isolation Reset Pushbutton.

6.1.4 Log time that charcoal filter fan stops.

Time 6.2 List P-9 "ALMQ4" setpoints in blanks provided.

R-36 [ cpm above background]

R-37 [ cpm]

R-38 [ cpm above background]

PT-17.4:5 6.2.1 List P-9 "WARNING" setpoints in blanks provided.

R-36 [ cpm above background]

R-37 [ cpm]

R-38 [ cpm above background]

'6.3 R-36 NOBLE GAS MONITOR 6.3.1 At R-36 monitor drawer, record '!as found" Alarm setting.

cpm 6.3.2 Set R-36 Alarm setting to the P-9 "ALARM" setpoint.

cpm 6.3.3 .At R-36 monitor drawer, record "as found" Warning setting.

cpm 6.3.4 Set R-36 Warning Setting to the P-9 "WARNING" setpoint.

cpm 6 '.5 Press check source and verify the following:

6.3.5.1 Channel .digital display indicates greater than "ALARM" setpoint as listed in step 6.3.2.

6.3.5.2 Channel Warning light (orange) illuminates.

6.3.5.3 Channel Alarm light (red) illuminates.

6.3.5.4 MCB alarm E-11 (Control Room HVAC Isolation) annun-ciates.

6.3.5.5 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the .closed position as 'indicated by status lights.

6.3.5.6 Charcoal filter fan starts.

6.3.5.7 Recirc dampers AKD07 and AKD09 open (in Air Handli.".g Room) .

6.3.6 Reset Control Room HVAC System when digital display decreases below "ALARM" setpoint and verify t!;e following:

6.3.6.1 Outside air inlet, exhaust relief and toilet exhaus dampers travel to the OPEN position as indicated ."y status lights.

PT-17.4:6 6.3.6.1.1 Recirc dampers AKD07 and AKD09 close (in Air Handling Room) .

6.3.6.2 Charcoal filter fan is off.

6.3.6.3 MCB annunciator E-11 clears.

6.3.7 Inde endent Verification Check:

6.3.7 ' R-36 Alarm set to step 6.3.2 setting.

6.3 '.2 R-36 Warning setting set to step 6.3.4 setting.

6.4 R-37 PARTICULATE MONITOR 6 '.1 At R-37 monitor drawer, record "as found" Alarm setting.

cpm 6.4.2 Set R-37 Alarm setting to the P-9 "ALARM" setpoint.

i cpm 6.4.3 At R-37 monitor drawer, record "as found" "WARNING" setting.

cpm 6.4.4 Set R-37 "WARNING" setting to the P-9 "WARNING" setpoint.

cpm 6.4.5 Press check source and verify the following:

6.4.5.1 Channel digital display indicates greater than "ALARM" setpoint as listed in Step 6.4.2.

6.4.5.2 Channel Warning light (orange) illuminates.

6.4.5.3 Channel Alarm light (red) illuminates.

6.4.5.4 MCB alarm E-11 (Control Room HVAC Isolation) annunciates.

6.4.5.5 Outside air inlet, exhaust relief and toilet exhaus.

dampers travel to the CLOSED position as indicated hy status lights.

6.4.5.6 Charcoal filter fan starts.

PT-17.4:7 6.4.6 Reset Control Room HVAC System when digital display decreases below "ALARM" setpoint and verify the follow-ing:

6.4.6.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.

6.4 '.2 Charcoal filter fan is off.

6.4.6.3 MCB annunciator E-ll alarm clears.

6.4.7 Independent Verification Check:

6.4.7.1 R-37 Alarm to Step 6.4.2 setting.

6.4.7.2 R-37 "WARNING" setting set to Step 6.4.4 setting.

6.5 R-38 IODINE MONITOR:

6.5.1 At R-38 monitor drawer, record "as found" Alarm setting. cpm 6 '.2 Set R-38 Alarm setting to the P-9 "AIAfQI" setpoint.

cpm 6.5.3 At R-38 monitor drawer, record "as found" Warning setting.

cpm 6.5.4 Set R-38 Warning Setting to the P-9 "WARNING" setpoint.

cpm 6.5.5 Press check source and verify the following:

6.5.5.1 Channel digital display indicates greater than alarm, setpoint as listed in step 6.5.2.

6.5.5.2 Channel Warning light (orange) illuminates.

6.5.5 ' Channel Alarm light (red) illuminates.

6.5,.5.4 MCB alarm E-11 (Control Room HVAC Isolation) annunciates.

6.5.5.5 Outside air inlet, exhaust relief and toilet exhaus:

dampers travel to the CLOSED position as indicated by status lights.

PT-17.4:8 6.5.5.6 Charcoal filter'fan starts.

6.5.6 'Reset Control Room HVAC System when digital display decreases below "ALARM" setpoint and verify the following:

6.5.6.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.

6.5.6.2 Charcoal filter fan is off.

6.5.6.3 MCB annunciator E-11 alarm clears.

6.5.7 Inde endent Verification Check:

6.5.7.1 R-38 Alarm set to step 6.5.2 setting.

6.5.7 ' R-38 Warning setting set to step 6.5.4 setting.

6.6 RADIATION DETECTOR FLOW SWITCH:

6.6.1 Secure the radiation monitor pump.

6.6.2 Verify the following:

6.6.2.1 n Low Flown light lit.

6.6.2.2 PPCS Point FHVACD "C.R. HVAC Isolation System Flow" in alarm.

6.6.2 ' MCB alarm E-11 (Control Room HVAC Isolation) annunciates.

6.6.2.4 Outside air inlet, exhaust relief and toilet exha s".

dampers travel to the CLOSED position as indicated ty status lights.

6.6.2.5 Charcoal filter fan starts.

6.6.2.6 Restart radiation monitor pump.

6.6.2.7 "Low Flow" light extinguished.

6.6.2.8 Verify PPCS Point FHVACD "C.R. HVAC Isolation Sys Flow" indicates normal.

PT-17.4:9 6.6.2.9 Reset Control Room HVAC System when digital display decreases below "ALARM" setpoint and verify the following:

6.6.2.9.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.

6.6.2.9.2 Charcoal filter fan is off.

6.6.2.9.3 MCB annunciator E-11 alarm clears.

6.7 TOXIC ANALYZER DEFEAT:

6.7. 1 Place the low flow trip bypass switch to "BYPASS" position.

6.7.2 Secure the running Toxic Gas Analyzer Sample Pump.

(Circle pump running A or B.)

6.7.3 Verify "LOW FLOW" lights illuminate.

6.8 AMMONIA DETECTOR:

6.8.1 Record as found HVAC Ammonia Analyzer value.

PPM 6.8.2 Turn the manual three-way valve from "SAMPLE" to the "CALIBRATE" position.

Turn the manual three-way valve from "ZERO" to "SPAN"

'.8.3 position.

6.8.4 Using a bottled gas, adjust the flow on the bottle regulator to slowly increase gas concentration as read on the detector.

6.8.5 Record the point at which the Ammonia Alarm lights :2 illuminate and actuate the Control Room ventilati recirc mode.

ACB ¹ Basis for ACCEPTANCE CRITERIA:

Limit/Value 10 PPM 2 1 PPM 94-324 A

6.8.6 Verify the following when the digital display on the Ammonia detector reaches 10 ppm:

6.8.6.1 MCB Alarm E-11 (Control Room HVAC Isolation) annun-ciates.

6.8.6.2 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED 'position as indicated by status lights.

6.8.6.3 Charcoal filter fan starts.

6.8.6.4 .Shut off Ammonia bottle and bleed pressure off the bottle and regulator.

6.8.6.5 Turn the manual three-way valve from "SPAN" to the "ZERO" gas position.

6.8.6.6 Turn the manual three way valve from "Calibrate" to Sample.

6. 8. 6. 7 Record ammonia detector display when stable.

PPM 6.8.6.7.1'erify ammonia detector display is ~ 1 PPM from the as found value in Step 6.8.1. If not, perform Step 6.8.6.8 inclusive, to purge the ammonia detector.

6.8.6.8 Perform the following to.purge the Ammonia detector. N/A Step 6.8.6 '.1 and 6.8.6.8.2 if purge is not required.

6.8.6.8.1 Restart the Toxic Gas Monitor pump that was running in step 6.7.2.

6.8.6.8.2 When the Ammonia detector digital display indicates a stable value z 1.0 ppm from the as found value in Step 6.8.1, then secure the running toxic gas monitor pump.

6.8.6.9 Reset Control Room HVAC system and verify the followi.-.q 6.8.6.9.1 Outside air inlet, exhaust relief and toilet exhaus dampers travel to the OPEN position as indicated status lights.

PT-17.4:11 6.8.6.9.2 Charcoal filter fan is off.

6.8.6.9.3 M.C.B. Annunciator E-11 alarm clears.

6.8. 6.X.O Inde endent V'erification Check:

6.8. 6.10.1 Manual Three-Way Valve"Sample" Position 6.8.6.10.2 Manual Three-Way Valve "Zero" Position I 6.8.6 '1 maintenance If test is being performed following calibration and/or of the Ammonia detector only and is complete, continue on with the Toxic Detector Reinstate section of this procedure, otherwise mark this step N/A.

6.9 CHLORINE DETECTOR BOTTLE CALIBRATION TEST GAS:

6.9.1 Record as found HVAC chlorine analyzer value.

PPM 6.9.2 Turn the manual three-way valve from "SAMPLE" to the "CALIBRATE" position.

6.9.3 Turn the manual three-way valve from "ZERO" to "SPAN" position. ~

6.9.4 Using a bottled gas, adjust the flow on the bottle regulator to slowly increase gas concentration as read on the detector.

6.9.5 Record the point at which the Chlorine Digital Display actuates the Control Room ventilation recirc mode ~

PPM ACB 0 Basis for ACCEPTANCE CRITERIA:

Limit/Value 1 PPM 2 .20 PPM 94-325 A 6.9.6 Verify the following when the digital display on Chlorine Detector reaches 1 ppm:

6.9.6.1 MCB Alarm E-11 (Control Room HVAC Isolation) annunciate-

6.9.6.2 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED position as indicated by status lights.

6.9.6.3 Charcoal filter fan starts.

6.9.6.4 Shut off Chlorine bottle and bleed pressure off the bottle and regulator.

6.9.6.5 Turn the manual three-way valve from "SPAN" to the "ZERO" gas position.

6.9.6.6 Turn the manual three way valve from. "Calibrate" to Sample.

6.9'.6.7 Record chlorine detector display when stable.

PPM 6.9.6.7.1 Verify chlorine detector display is g .2 ppm from the as found'value in Step 6.9.1. If not, perform Step 6.9.6.8 inclusive to purge the chlorine detector.

6.9.6.8 Perform the following to purge the Chlorine detector.

N/A step required.

6.9.6.8.1 and 6.9.6.8.2 if purge is not 6.9.6.8.1 Restart the Toxic Gas Monitor pump that was running in step 6.7.2.

6.9.6.8.2 When the Chlorine detector digital display indicates a stable value g .2 ppm of the as found value in Step 6.9.1. Then secure the running toxic gas monitor pump.

6.9.6.9 Reset Control Room HVAC system and verify the following:

6.9.6.9.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights'.9.6.9.2 Charcoal Filter Fan is off.

6.9.6.9.3 M.C.B. Annunciator E-ll Alarm clears.

PT-17.4:13 6.9.6.10 Inde endent Verification Check:

6.9.6.10.1 Manual Three-Way Valve"Sample" Position 6.9.6.10.2 Manual Three-Way Valve "Zero" Position 6.9.6.11 If test is being performed following calibration and/or maintenance of the chlorine detector only and is complete, continue on with the Toxic Anal zer Reinstate section of this procedure, otherwise mark this step N/A.

6.10 CHLORINE DETECTOR CHLORINE MAST CALIBRATION UNIT:

6.10.1 Record as found HVAC chlorine analyzer value.

PPM 6.10.2 Turn the manual three-way valve from "SAMPLE" to the "CALIBRATE" position.

6.10.3 Turn the manual three-way valve from "ZERO" to "SPAN" position.

6.10.4 Connect Mast Calibration Unit to test connection as follows:

6.10.4.1 Close the'alves on the lower inlet side and upper outlet side of the chlorine probe flow tube.

6.10.4.2 Remove the Swagelok plugs from both the inlet and outlet test tees.

6.10.4.3 Connect the output tubing from the MAST calibration uni" to the upper outlet test tee.

NOTE: This is the "backflow" method preferred by ANACON to avoid probe tip saturation.

6.10.5 Pull gas select valve on the Mast Calibration Unit inject gas.

6.10.6 Record the point at which the Chlorine digital disp'. s, actuates the Control Room ventilation recirc mode.

ACB ¹ Basis for ACCEPTANCE CRITERIA:

Limit/Value 1 PPM + .20 ppm 94-325 A

PT-17.4:14 6.10.7 Verify the following when the digital display on the Chlorine Detector reaches 1 ppm:

6.10.7.1 MCB alarm E-11 (Control Room HVAC Isolation) annun-ciates.

6.10.7.2 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED position as indicated by status lights.

6.10.7.3 Charcoal filter fan starts.

6.10.8 Remove the MAST calibration unit as follows:

6.10.8.1 Disconnect the MAST calibration Unit from the test tee.

6.10 '.2 Open the lower inlet valve and upper outlet valve of the chlorine probe flow tube.

Verified By:

6.10.8.3 Install the Swagelok plugs in both the inlet and outlet test tees.

Verified By:

6.10.9 Turn the manual three-way valve from "SPAN" to the "ZERO" gas position.

6.10.10 Turn the manual three-way valve from "CALIBRATE" to "SAMPLE".

6.10.11 Record chlorine detector display when stable.

6.10.11.1 Verify chlorine detector display is z .2 ppm from the .s found value in Step 6.10.1. If not, perform Step 6.10.:.

inclusive to purge the chlorine detector.

6.10.12 Perform the following to purge the Chlorine detect.:

N/A step required.

6.10.12.1 and 6.10.12.2 if purge is

PT-17.4:15 6.10.12.1 Restart the Toxic Gas Monitor pump that was running in step 6.7.2.

6.10.12.2 When the Chlorine detector digital display indicates a stable value g .2 ppm of the as found value in Step 6.10.1, then secure the running Toxic Gas Monitor Pump.

6.10.13 Reset the Control Room HVAC system and verify the following:

6.10.13.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.

6.10.13.2 Charcoal filter fan is "OFF".

6.10.13.3 MCB annunciator E-11 Alarm clears.

6.10.14 Inde en ent Verification Check:

6.10.14.1 Manual Three-way Valve. "SAMPLE" position 6.10.14.2 Manual Three-way Valve. "ZERO" position 6.10.15 If test maintenance is being performed following calibration and/or of the Chlorine Detector and is complete, continue on with the Toxic Detector Reinstate section of this procedure, otherwise mark this step N/A.

6.11 AMMONIA DETECTOR FLOW SWITCH:

6.11.1 Restart the Toxic Gas 'Monitor Pump that was running in step 6.7.2 (circle A or B to run) 6.11.1 ' Place the Toxic Gas Detector Low Flow Bypass Switch "NORMAL" position.

6. 11.1.2 Reduce the flow through ammonia detector to c 2.0 SCFM.

6.11.2 Verify the following:

6.11.2.1 "Low. Flow" light lit.

6.11.2.2 PPCS Point FHVACD 'C.R. HVAC Isolation System Flow'larm.

PT-17.4:16 6.11.2.3 MCB alarm E-11 (Control Room HVAC Isolation) annunciates.

6.11 '.4 Outside dampers air inlet, travel to the exhaust CLOSED relief and position toilet as exhaust indicated by status light@.

6.11.2.5 Charcoal filter fan starts.

6.11.2.6 Increase flow to > 2.25 SCFM.

6.11.2.7 Verify "Low Flow" light extinguished.

6.11.2.8 Verify PPCS Point FHVACD "C.R. HVAC Isolation System Flo'w" indicates normal.

6.11.2.9 Reset Control Room HVAC System.

6.11.2.10 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status lights.

6.11.2.11 Charcoal filter fan is off.

6.11.2.12 MCB annunciator E-11 alarm clears.

6.12 CHLORINE MONITOR FLOW SWITCH:

6.12.1 A or B Gas Monitor Pump Running. (Circle Running) 6.12.1.1 Verify and/or place the Toxic Gas Detector Bypass Switch in "NORMAL" position.

6.12.1,2 Reduce the flow through the chlorine monitor to <0.25 SCFM.

6.12.2 Verify the following:

6.12.2.1 Low flow light PPCS Control Room low flow alarm.

lit.'.12.2.2 6.12.2.3 MCB alarm E-11 (Control Room HVAC Isolation) annunciates.

PT-17.4:17 6.12.2.4 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED position as indicated by status lights.

6.12.2.5 Charcoal filter fan starts.

6.12.2.6 Increase flow to 0.25 SCFM or greater.

6.12.2.7 Verify "Low Flow" light extinguished.

6.12.2.8 Verify PPCS Point FHVACD "C.R. HVAC Isolation System Flow" indicates normal.

6.12.2.9 Reset Control Room HVAC System and verify the following:

6.12.2.9.1 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the OPEN position as indicated by status, lights.

6 '2.2.9.2 Charcoal filter fan is off.

6.12.2.9.3 MCB annunciator E-11 alarm clears.

6.13 CONTROL ROOM MANUAL RECIRCULATION ACTUATION:

6.13.1 Depress the "Control Room Manual Recirculation" pushbutton.

6.13.2 Verify the following:

6.13.3 MCB alarm E-11 (Control Room HVAC Isolation) annun-ciates.

6. 13.4 Outside air inlet, exhaust relief and toilet exhaust dampers travel to the CLOSED position as indicated by status lights.

6.13.5 Charcoal filter fan starts.

6.13.6 Reset Control Room HVAC System and verify the following:

6.13.6.1 Outside air inlet, exhaust relief and toilet exhaust, dampers travel to the OPEN position as indicated by status lights.

6.13.6.2 Charcoal filter fan is off.

PT-17.4:18 6.13.6.3 MCB annunciator E-11 alarm clears.

6.14 TOXIC DETECTOR REINSTATE:

6.14.1 Start or ensure running the sample pump that was secured in step 6.7.2 and verify proper flow rates:

Ammonia > 2.25 scfm Chlorine > 0.25 scfm 6.14.2 Verify toxic gas ammonia "Low Flow" light extinguished.

6 '4.3 Verify toxic gas chlorine "Low Flow" light extinguished.

6.14.4 Verify'he low flow bypass switch is in'NORMAL" position.

PT-17.4:19 6.15 Inde endent Verification Check:

6.15.1 Verify sample pump on. Mark the pump that is not running N/A.

"A" Running "B" Running 6.15.2 Toxic Gas Monitor Low Flow Bypass Switch in the "Normal" Position.

6.16 Log total run time on MCB "Control Room HVAC System Charcoal Filter In-Service Log".

6.17 Notify Head Control Operator that test is complete.

COMMENTS:

COMPLETED BY:

DATE COMPLETED:

HEAD CONTROL OPERATOR:

SHIFT SUPERVISOR:

RESULTS AND TEST REVIEW: DATE: