{{#Wiki_filter:DONALDC.COOKNUCLEARPLANTUNIT2CYCLE11COREOPERATING LIMITSREPORT(COLR)Revision5September 199797i0080032 970930PDRADOCK05000316RPDR COLRforDONALDC.COOKNUCLEARPLANTUNIT2CYCLE11-SEPTEMBER 19971.0COREOPERATING LIMITSREPORTThisCoreOperating LimitsReportforDonaldC.CookNuclearPlantUnit2Cycle11hasbeenpreparedinaccordance withtherequirements ofTechnical Specification 6.9.1.9.TheTechnical Specifications affectedbythisreportarelistedbelow:3/4.1.1.4 3/4.1.3.1 3/4.1.3.4 3/4.1.3.5 3/4.1.3.6 3/4.2.13/4.2.23/4.2.33/4.2.6Moderator Temperature Coefficient MovableControlAssemblies GroupHeightRodDropTimeShutdownRodInsertion LimitsControlRodInsertion LimitsAxialFluxDifference
{{#Wiki_filter:DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11 CORE OPERATING LIMITS REPORT (COLR)Revision 5 September 1997 97i0080032 970930 PDR ADOCK 05000316 R PDR COLR for DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11-SEPTEMBER 1997 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report for Donald C.Cook Nuclear Plant Unit 2 Cycle 11 has been prepared in accordance with the requirements of Technical Specification 6.9.1.9.The Technical Specifications affected by this report are listed below: 3/4.1.1.4 3/4.1.3.1 3/4.1.3.4 3/4.1.3.5 3/4.1.3.6 3/4.2.1 3/4.2.2 3/4.2.3 3/4.2.6 Moderator Temperature Coefficient Movable Control Assemblies Group Height Rod Drop Time Shutdown Rod Insertion Limits Control Rod Insertion Limits Axial Flux Difference
-(AFD)HeatFluxHotChannelFactor-Fz(Z)NuclearEnthalpyHotChannelFactor-F"<<Allowable PowerLevel-(APL)Page1of11Revision5 llCOLRforDONALDC.COOKNUCLEARPLANTUNIT2CYCLE11-SEPTEMBER 1997Thecycle-specific parameter limitsforthespecifications listedinSection1.0arepresented inthefollowing subsections.
-(AFD)Heat Flux Hot Channel Factor-Fz(Z)Nuclear Enthalpy Hot Channel Factor-F"<<Allowable Power Level-(APL)Page 1 of 11 Revision 5 l l COLR for DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11-SEPTEMBER 1997 The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections.
Theselimitshavebeendeveloped usingtheNRC-approved methodologies specified inTechnical Specification 6.9.1.9.2.1Moderator TemeratureCoefficient (Specification 3/4.1.1.4) 2.1.1TheModerator Temperature Coefficient (MTC)limitsare:TheBOL/ARO-MTC shallbelesspositivethanthevaluegiveninFigurel.TheEOL/ARO/RTP-MTC shallbelessnegativethan-5.00E-4b,k/k/'F.
These limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.9.2.1 Moderator Tem erature Coefficient (Specification 3/4.1.1.4) 2.1.1 The Moderator Temperature Coefficient (MTC)limits are: The BOL/ARO-MTC shall be less positive than the value given in Figure l.The EOL/ARO/RTP-MTC shall be less negative than-5.00E-4 b,k/k/'F.This limit is based on a Tavg program witll HFP vessel Tavg of 574 F where: ARO stands for All Rods Out BOL stands for Beginning of Cycle Life EOL stands for End of Cycle Life HFP stands for Hot Full Thermal Power RTP stands for Rated Thermal Power 2.1.2 The MTC Surveillance limit is: The 300 ppm/ARO/RTP-MTC should be less negative than or equal to-4.15E-4 hk/k/'F at a vessel Tavg of 574'F.Page 2 of 11 Revision 5 A COLR for DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11-SEPTEMBER 1997 FIGURE 2 ROD BANK INSERTION LIMITS VERSUS THERMAL POWER FOUR-LOOP OPERATION 250 225 I-'(54.5, 231)103 STEP OVERLAP'200 I (10 0~189)z 0 i 175'I 150 I (BANK C)(0, 128)0 100 4 1 0 75'(BANK D)I, 50 25 0 9 I.,', (090)'l.!t I Q%IQ%2Q%3Q%4Q%5Q%6Q%7Q%S0%9Q%IPQ%RELATIVE POWER Page S of 11 Revision 5}}
ThislimitisbasedonaTavgprogramwitllHFPvesselTavgof574Fwhere:AROstandsforAllRodsOutBOLstandsforBeginning ofCycleLifeEOLstandsforEndofCycleLifeHFPstandsforHotFullThermalPowerRTPstandsforRatedThermalPower2.1.2TheMTCSurveillance limitis:The300ppm/ARO/RTP-MTC shouldbelessnegativethanorequalto-4.15E-4hk/k/'FatavesselTavgof574'F.Page2of11Revision5 ACOLRforDONALDC.COOKNUCLEARPLANTUNIT2CYCLE11-SEPTEMBER 1997FIGURE2RODBANKINSERTION LIMITSVERSUSTHERMALPOWERFOUR-LOOP OPERATION 250225I-'(54.5,231)103STEPOVERLAP'200I(100~189)z0i175'I150I(BANKC)(0,128)010041075'(BANKD)I,502509I.,',(090)'l.!tIQ%IQ%2Q%3Q%4Q%5Q%6Q%7Q%S0%9Q%IPQ%RELATIVEPOWERPageSof11Revision5}}

Revision as of 07:49, 6 July 2018

Rev 5 to DC Cook Nuclear Plant Unit 2 Cycle 11 Colr.
ML17333B066
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 09/30/1997
From:
INDIANA MICHIGAN POWER CO.
To:
Shared Package
ML17333B065 List:
References
NUDOCS 9710080032
Download: ML17333B066 (4)


Text

DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11 CORE OPERATING LIMITS REPORT (COLR)Revision 5 September 1997 97i0080032 970930 PDR ADOCK 05000316 R PDR COLR for DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11-SEPTEMBER 1997 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report for Donald C.Cook Nuclear Plant Unit 2 Cycle 11 has been prepared in accordance with the requirements of Technical Specification 6.9.1.9.The Technical Specifications affected by this report are listed below: 3/4.1.1.4 3/4.1.3.1 3/4.1.3.4 3/4.1.3.5 3/4.1.3.6 3/4.2.1 3/4.2.2 3/4.2.3 3/4.2.6 Moderator Temperature Coefficient Movable Control Assemblies Group Height Rod Drop Time Shutdown Rod Insertion Limits Control Rod Insertion Limits Axial Flux Difference

-(AFD)Heat Flux Hot Channel Factor-Fz(Z)Nuclear Enthalpy Hot Channel Factor-F"<<Allowable Power Level-(APL)Page 1 of 11 Revision 5 l l COLR for DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11-SEPTEMBER 1997 The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections.

These limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.9.2.1 Moderator Tem erature Coefficient (Specification 3/4.1.1.4) 2.1.1 The Moderator Temperature Coefficient (MTC)limits are: The BOL/ARO-MTC shall be less positive than the value given in Figure l.The EOL/ARO/RTP-MTC shall be less negative than-5.00E-4 b,k/k/'F.This limit is based on a Tavg program witll HFP vessel Tavg of 574 F where: ARO stands for All Rods Out BOL stands for Beginning of Cycle Life EOL stands for End of Cycle Life HFP stands for Hot Full Thermal Power RTP stands for Rated Thermal Power 2.1.2 The MTC Surveillance limit is: The 300 ppm/ARO/RTP-MTC should be less negative than or equal to-4.15E-4 hk/k/'F at a vessel Tavg of 574'F.Page 2 of 11 Revision 5 A COLR for DONALD C.COOK NUCLEAR PLANT UNIT 2 CYCLE 11-SEPTEMBER 1997 FIGURE 2 ROD BANK INSERTION LIMITS VERSUS THERMAL POWER FOUR-LOOP OPERATION 250 225 I-'(54.5, 231)103 STEP OVERLAP'200 I (10 0~189)z 0 i 175'I 150 I (BANK C)(0, 128)0 100 4 1 0 75'(BANK D)I, 50 25 0 9 I.,', (090)'l.!t I Q%IQ%2Q%3Q%4Q%5Q%6Q%7Q%S0%9Q%IPQ%RELATIVE POWER Page S of 11 Revision 5