{{#Wiki_filter:ACCELERATEDDTIUBUTIONDEMONSTIONSYSTEMk~"REGULATORYINFORMATIONDISTRIBUTIONSYSTEM(RIDS)'CCESSIONNBR:9202060130DOC.DATE:92/01/29NOTARIZED:NOFACIL:50-244RobertEmmetGinnaNuclearPlant,Unit1,RochesterGAUTH.NAMEAUTHORAFFILIATIONBACKUS,W.H.RochesterGas6ElectricCorp.MECREDY,R.C.RochesterGas6ElectricCorp.RECIP.NAMERECIPIENTAFFILIATIONDOCKET05000244R
{{#Wiki_filter:ACCELERATED DTIUBUTION DEMONSTIONSYSTEMk~"REGULATORY INFORMATION DISTRIBUTION SYSTEM(RIDS)'CCESSION NBR:9202060130 DOC.DATE:
92/01/29NOTARIZED:
NOFACIL:50-244 RobertEmmetGinnaNuclearPlant,Unit1,Rochester GAUTH.NAMEAUTHORAFFILIATION BACKUS,W.H.
Rochester Gas6ElectricCorp.MECREDY,R.C.
Rochester Gas6ElectricCorp.RECIP.NAME RECIPIENT AFFILIATION DOCKET05000244R


==SUBJECT:==
==SUBJECT:==
LER91-010-00:on911230,duringoperatorreviewofplant,processcomputerlogs,utildiscoveredthatinvaliddatahadbeenusedforcalculation.CausedbyinvalidinputfromLEFM.LEFMHP-85BComputerwasreinitialized.W/920129ltr.DISTRIBUTIONCODE:IE22TCOPIESRECEIVED:LTRENCLSIZE:.TITLE:50.73/50.9Licensee"EventReport(LER),IncidentRpt,etc.NOTES:LicenseExpdateinaccordancewithloCFR2,2.109(9/19/72).DS05000244ADRECIPIENTIDCODE/NAMEPD1-3LAJOHNSON,AINTERNAL:ACNWAEOD/DSP/TPABNRR/DET/ECMB9HNRR/DLPQ/LHFB10NRR/DOEA/OEABNRR/DST/SELBSDNRR/D~SJSLB.SDlRE-'CE2RGNIL01EXTERNALEGGGBRYCEgJ~HNRCPDRNSICPOORE,W.COPIESLTTRENCL11.11221=;111111111111111331"111,RECIPIENTIDCODE/NAMEPD1-3PDAEOD/DOAAEOD/ROAB/DSPNRR/DET/EMEB7ENRR/DLPQ/LPEB10NRR/DREP/PRPB11NRR/DST/SICBSH3NRR/DST/SRXBSERES/DSIR/EIBLSTLOBBYWARDNSICMURPHY,G.ANUDOCSFULLTXTCOPIESLTTRENCL111122111122111111111111DQ~~opgys7>//~7DNOTETOALL"RIDS"RECIPIENTS:PLEASEHELPUSTOREDUCEiVASTE!CONTACTTHEDOCUMENTCONTROLDESK,ROOMP1-37(EXT.20079)TOELIMINATEYOURNAMEFROMDISTRIBUTIONLISTSFORDOCUMENTSYOUDON'TNEED!DDSFULLTEXTCONVERSION'REQUIREDTOTALNUMBEROFCOPIESREQUIRED:LTTR31ENCL31  
LER91-010-00:on 911230,during operatorreviewofplant,processcomputerlogs,utildiscovered thatinvaliddatahadbeenusedforcalculation.
CausedbyinvalidinputfromLEFM.LEFM HP-85BComputerwasreinitialized.W/920129 ltr.DISTRIBUTION CODE:IE22TCOPIESRECEIVED:LTR ENCLSIZE:.TITLE:50.73/50.9 Licensee"Event Report(LER),IncidentRpt,etc.NOTES:License Expdateinaccordance withloCFR2,2.109(9/19/72).
DS05000244ADRECIPIENT IDCODE/NAME PD1-3LAJOHNSON,A INTERNAL:
ACNWAEOD/DSP/TPAB NRR/DET/ECMB 9HNRR/DLPQ/LHFB10 NRR/DOEA/OEAB NRR/DST/SELB SDNRR/D~SJS LB.SDlRE-'CE2RGNIL01EXTERNALEGGGBRYCEgJ~HNRCPDRNSICPOORE,W.COPIESLTTRENCL11.11221=;111111111111111331"111,RECIPIENT IDCODE/NAME PD1-3PDAEOD/DOAAEOD/ROAB/DS PNRR/DET/EMEB 7ENRR/DLPQ/LPEB10 NRR/DREP/PRPB11 NRR/DST/SICBSH3 NRR/DST/SRXB SERES/DSIR/EIBLSTLOBBYWARDNSICMURPHY,G.A NUDOCSFULLTXTCOPIESLTTRENCL111122111122111111111111DQ~~opgys7>//~
7DNOTETOALL"RIDS"RECIPIENTS:
PLEASEHELPUSTOREDUCEiVASTE!CONTACTTHEDOCUMENTCONTROLDESK,ROOMP1-37(EXT.20079)TOELIMINATE YOURNAMEFROMDISTRIBUTION LISTSFORDOCUMENTS YOUDON'TNEED!DDSFULLTEXTCONVERSION'REQUIRED TOTALNUMBEROFCOPIESREQUIRED:
LTTR31ENCL31  


"JncC'OCHESTERGASANDELECTRICCORPORATION0I~II~I~44rTOOK11KTC~89EASTAVENUE,ROCHESTERN.K14649-0001ROBERTC.MECREDYVicePresidentCinnaNuclearProductionTELEPttONEAAEACODE7165462700January29,1992U.S.NuclearRegulatoryCommissionDocumentControlDeskWashington,DC20555
"JncC'OCHESTER GASANDELECTRICCORPORATION 0I~II~I~44rTOOK11KTC~89EASTAVENUE,ROCHESTER N.K14649-0001 ROBERTC.MECREDYVicePresident CinnaNuclearProduction TELEPttONE AAEACODE7165462700January29,1992U.S.NuclearRegulatory Commission DocumentControlDeskWashington, DC20555


==Subject:==
==Subject:==
'nLER91-010,DuringOperatorReviewofPlantProcessComputerLogs,ItWasDiscoveredThatInvalidDataHadBeenUsedForCalorimetricCalculationR.E.GinnaNuclearPowerPlantDocketNo.50-244ThiseventisbeingvoluntarilyreportedusingtheguidanceofNUREG-1022(LicenseeEventReportSystem),andSupplementNo.1toNUREG-1022.Thisreportisintendedtoalertotherutilitieswhichmayhavesimilarsystems.Thiseventisrelatedto,butdoesnotmeet,thereportingrequirementsof10CFR50.73,item(a)(2)(i)(B).Item(a)(2)(i)(B)requiresreportingof"anyoperationorconditionprohibitedbytheplant'sTechnicalSpecifications".TheattachedLicenseeEventReportLER91-010isherebyvoluntarilysubmitted.Thiseventhasinnowayaffectedthepublic'shealthandsafety.Verytrulyyours,xc4RobertC.MecredyU.S.NuclearRegulatoryCommissionRegionI475AllendaleRoadKingofPrussia,PA19406GinnaUSNRCSeniorResidentInspector~~Pi~Lri30V3c.)9202060130920129PDRADOCK050002448PDRgpg 0  
'nLER91-010,DuringOperatorReviewofPlantProcessComputerLogs,ItWasDiscovered ThatInvalidDataHadBeenUsedForCalorimetric Calculation R.E.GinnaNuclearPowerPlantDocketNo.50-244Thiseventisbeingvoluntarily reportedusingtheguidanceofNUREG-1022 (Licensee EventReportSystem),andSupplement No.1toNUREG-1022.
>>ACy>><<SOOIO4$)LICENSEEEVENTREPORT(LERlUWNUCLSA11IOULATOA1COO<<)~ONAtyNOTIOONSNO.$1IO0IOVIXSYASII/SvssyACILITYNAA)aIllR.E.GinnaNuclearPowerPlantOOCXSTNV<<tallQlAo6oo0244>0)08<<II)4DuringOperaorReviewofPlantProcessComputerLogs,ItWasDiscoveredThatInvalidDataHadBenUimetr'TINTOATSISILSNNU<<SINIIIAIAOAToATI1)IOTHI1IACILITIISINYOLVIONlNO>>THOAYTIAIIYIA1)I0VI>>1IAL"'VNJOVHV>>IIA-.I'WaasIAOAYTtA1yAO4TTHAH)AOOCXITNVNSIAISI060001230911010000199206000OAIAATINO<<OOINI~ONI1LavtL09"a+g)~ig@i.'HISAlyOATNSUSINTTIOyVASVANTT)OAO)I~ISO.NN41IIIIISOANNIllllllSO.AOS4IIIII<<)$0AOS41))lr>>l$OAN4)ll)ly)$0.AOOINStoa4II)l~OMNIQI~O.T$4lallt~O.T$4)Q)lalSOI$4)QII<<I~O.T$4)QIIN)~O.T$41llIlylSO.T$4)QlNIIIO.T$4)0II>>XIIAI~O.T$4)QII<<IINI~O.T$4)QIlaI0THtAIOVIAININTSOyISCSAf:ICA>>e>>VW>>A>>ey<<A~lllTL1)4)X'oTHa1ISA>>>>y4~A>>A>>AAOIArAAL>>1CsaESSA)LICINIIICONTACTSONTHNLail0$)NAUIWesleyH.BackusANIACOOSTechnicalAssistanttotherationsManaer315CO<<yLITIONILINIIOAIACHCO<<AONSNTSAILV1lOIICAI~IOINTHN1tyOAT11$)TSLtyHONINVHSIIICAVSISTSTINCOUAONINTUANUI'ACTVNI1IAONTASLlTONy10$Rh'I'.PriIg<qg&I''>ggi9%j)'..gpssCAUIISTITSLICO<<yONINTNANUSACTUNI1lyONTASLTONyAOSwjv{IN+Jvwg@4i-..)(;Q>~b)<XI0W12'0Nyg~t)4pge~%A"'o'~<V~~~UyyLII4INTALAITOATIXylCTIO114Ttlory>>,y>>AA>>>>sxyscrsosvsa>>ss)o>>oArslNOASSTAACTILAA>>>>WO>>>>>>,I1,AA>>su>>varyNf>>AA<<V>>~rITA>>>>N>>AAA>>llit)tXAICTIOLVSLVSSIONOATSIIIIVONTHCAYTIA1OnDecember30,1991atapproximately1830EST,withthereactoratapproximately984fullpower,theControlRoomForeman,whileperformingareviewofthehourlyPlantProcessComputerSystem(PPCS)logs,determinedthattheLeadingEdgeFlowMeter(LEFM}datausedbythePPCStocalculatecalorimetrics,wasinvalidfrom1800EST,December20,1991toapproximately1830EST,December.30,1991.Thiseventisbeingvoluntarilyreportedtoalertotherutilitieswhichmayhavesimilarsystems.TheControlRoomoperatorsnotifiedthereactorengineerandreinitializedtheLEFMcomputer.Afterreinitialization,theLEFMprintoutvaluesandPPCSvaluesreturnedtoexpected/normalindications.Correctiveactionsincluderevi'sionstotheaffectedprocedurestorequirecheckingtheoperationoftheLEFMpriortoperformingcalorimetricsandtheadditionofahigh'alarmonPPCSindicatingafailuremayhaveoccurred.TheimmediatecausewasidentifiedasafailureoftheLEFMHP-85Bcomputer.>>1CI>>>>SOSISO$1  
Thisreportisintendedtoalertotherutilities whichmayhavesimilarsystems.Thiseventisrelatedto,butdoesnotmeet,thereporting requirements of10CFR50.73, item(a)(2)(i)(B).Item(a)(2)(i)(B)requiresreporting of"anyoperation orcondition prohibited bytheplant'sTechnical Specifications".
TheattachedLicenseeEventReportLER91-010isherebyvoluntarily submitted.
Thiseventhasinnowayaffectedthepublic'shealthandsafety.Verytrulyyours,xc4RobertC.MecredyU.S.NuclearRegulatory Commission RegionI475Allendale RoadKingofPrussia,PA19406GinnaUSNRCSeniorResidentInspector
~~Pi~Lri30V3c.)9202060130 920129PDRADOCK050002448PDRgpg 0  
>>ACy>><<SOOIO4$)LICENSEEEVENTREPORT(LERlUWNUCLSA11IOULATOA1 COO<<)~ONAtyNOTIOONSNO.$1IO0IOVIXSYASII/SvssyACILITYNAA)aIllR.E.GinnaNuclearPowerPlantOOCXSTNV<<tallQlAo6oo0244>0)08<<II)4DuringOperaorReviewofPlantProcessComputerLogs,ItWasDiscovered ThatInvalidDataHadBenUimetr'TINTOATSISILSNNU<<SINIIIAIAOAToATI1)IOTHI1IACILITIIS INYOLVIONlNO>>THOAYTIAIIYIA1)I0VI>>1IAL"'VNJOVHV>>IIA-.I'WaasIA OAYTtA1yAO4TTHAH)AOOCXITNVNSIAISI 060001230911010000199206000OAIAATINO
<<OOINI~ONI1LavtL09"a+g)~ig@i.'HISAlyOATNSUSINTTIO yVASVANTT)OAO)I~ISO.NN41IIIIISOANNIllllll SO.AOS4IIIII<<)$0AOS41))lr>>l$OAN4)ll)ly)$0.AOOINStoa4II)l
~OMNIQI~O.T$4lallt~O.T$4)Q)lalSOI$4)QII<<I~O.T$4)QIIN)~O.T$41llIlylSO.T$4)QlNIIIO.T$4)0II>>XIIAI~O.T$4)QII<<IINI
~O.T$4)QIlaI0THtAIOVIAININTS OyISCSAf:ICA>>e>>VW>>A>>ey<<A~lllTL1)4)X'oTHa1ISA>>>>y4~A>>A>>AAOIArAAL>>1CsaESSA)LICINIIICONTACTSONTHNLail0$)NAUIWesleyH.BackusANIACOOSTechnical Assistant totherationsManaer315CO<<yLITIONILINIIOAIACHCO<<AONSNT SAILV1lOIICAI~IOINTHN1tyOAT11$)TSLtyHONI NVHSIIICAVSISTSTINCOUAONINT UANUI'ACTVNI1IAONTASLlTONy10$Rh'I'.Pri Ig<qg&I''>
ggi9%j)'..gpssCAUIISTITSLICO<<yONINT NANUSACTUNI1lyONTASLTONyAOSwjv{IN+Jv wg@4i-..)(;Q>~b)<
XI0W12'0Nyg~t)4pge~%A"'o'~<V~~
~UyyLII4INTAL AITOATIXylCTIO114Ttlory>>,y>>AA>>>>sxyscrsosvsa>>ss)o>>
oArslNOASSTAACTILAA>>>>WO>>>>>>,I1,AA>>su>>vary Nf>>AA<<V>>~rITA>>>>N>>AAA>>llit)tXAICTIOLVSLVSSION OATSIIIIVONTHCAYTIA1OnDecember30,1991atapproximately 1830EST,withthereactoratapproximately 984fullpower,theControlRoomForeman,whileperforming areviewofthehourlyPlantProcessComputerSystem(PPCS)logs,determined thattheLeadingEdgeFlowMeter(LEFM}datausedbythePPCStocalculate calorimetrics, wasinvalidfrom1800EST,December20,1991toapproximately 1830EST,December.30,1991.Thiseventisbeingvoluntarily reportedtoalertotherutilities whichmayhavesimilarsystems.TheControlRoomoperators notifiedthereactorengineerandreinitialized theLEFMcomputer.
Afterreinitialization, theLEFMprintoutvaluesandPPCSvaluesreturnedtoexpected/normal indications.
Corrective actionsincluderevi'sions totheaffectedprocedures torequirecheckingtheoperation oftheLEFMpriortoperforming calorimetrics andtheadditionofahigh'alarm onPPCSindicating afailuremayhaveoccurred.
Theimmediate causewasidentified asafailureoftheLEFMHP-85Bcomputer.
>>1CI>>>>SOSISO$1  


IIACleesWAI$4$ILICENSEEEVENTREPORTILER)TEXTCONTINUATIONU$,ISUOLSAAASOULAToAvcoeeMISCIbllSASSAOV$0OM$IlO$1$0%104$SSIA$5~I)I1$SACILITYIIAMCIIIOOCKlTIIUI&SAl1ILlAIIUSSOSIII~ISIOVSIITIAL~IM1VISIOMMe~AO$1$IR.E.NuclearPower,PlantTSITIls~~sIeeweelvee~lVACSese~$IIIllosooo2449.1-010-00020FO8PRE-EVENTPLANTCONDITIONSTheplantwasatapproximately98%steadystatereactorpowerwithnomajoractivitiesinprogress.TheControlRoomForeman(CRF)wasreviewingthehourlyPlantProcessComputerSystem.(PPCS)logs.DESCRIPTIONOF-EVENTA.DATESANDAPPROXIMATETIMESOFMAZOROCCURRENCES:oDecember20,1991,1800EST:Eventdateandapproximatetime.oDecember30,1991,1830EST:Discoverydateandapproximatetime.oDecember30,1991,2055EST:Performedcalori-metricusingBartonD/PcellsoptionandplantthermalpowerwasdeterminedtobeapproximatelythesameasthatcalculatedusingtheLeadingEdgeFlow'eter(LEFM)option.B.EVENT:OnDecember30,1991atapproximately1830EST,withthereactoratapproximately98%fullpower,theCRF,whileperformingareviewofthehourlyPPCSlogs,determinedthattheLEFMdatausedbythePPCStocalculatecalorimetrics,wasinvalidfrom1800EST,December20,1991toapproximately1830'EST,December30,1991.Thisdeterminationwasbasedonthefollowinginformation:oTheLEFMFeedwater(FW)Flowconfidencelevelwas100.0%formostofthetimeperiodinquestion(Ztshouldbelessthan100%andsomevariationisexpected).~IACsOAes$$SAI$4$l  
IIACleesWAI$4$ILICENSEEEVENTREPORTILER)TEXTCONTINUATION U$,ISUOLSAAASOULAToAv coeeMISCIbll SASSAOV$0OM$IlO$1$0%104$SSIA$5~I)I1$SACILITYIIAMCIIIOOCKlTIIUI&SAl1ILlAIIUSSOSII I~ISIOVSIITIAL~IM1VISIOMMe~AO$1$IR.E.NuclearPower,PlantTSITIls~~sIeeweelvee~lVACSese~$IIIllosooo2449.1-010-00020FO8PRE-EVENT PLANTCONDITIONS Theplantwasatapproximately 98%steadystatereactorpowerwithnomajoractivities inprogress.
TheControlRoomForeman(CRF)wasreviewing thehourlyPlantProcessComputerSystem.(PPCS)logs.DESCRIPTION OF-EVENTA.DATESANDAPPROXIMATE TIMESOFMAZOROCCURRENCES:
oDecember20,1991,1800EST:Eventdateandapproximate time.oDecember30,1991,1830EST:Discovery dateandapproximate time.oDecember30,1991,2055EST:Performed calori-metricusingBartonD/Pcellsoptionandplantthermalpowerwasdetermined tobeapproximately thesameasthatcalculated usingtheLeadingEdgeFlow'eter (LEFM)option.B.EVENT:OnDecember30,1991atapproximately 1830EST,withthereactoratapproximately 98%fullpower,theCRF,whileperforming areviewofthehourlyPPCSlogs,determined thattheLEFMdatausedbythePPCStocalculate calorimetrics, wasinvalidfrom1800EST,December20,1991toapproximately 1830'EST, December30,1991.Thisdetermination wasbasedonthefollowing information:
oTheLEFMFeedwater (FW)Flowconfidence levelwas100.0%formostofthetimeperiodinquestion(Ztshouldbelessthan100%andsomevariation isexpected).
~IACsOAes$$SAI$4$l  


IIAC$ereMI$4$ILICENSEEEVENTREPORTILER)TEXTCONTINUATIONU.$.IIUCLEAAAEOULATOATCOAIAIIION/AftAOVEO0+5hO$I$0&IOAEXP>AE5~I$I$$AACILITYIIAAIEIllCOCKETIIUAWEAIEILEAIIIAACI1I~ISAOVANTIALVOW)<~IUUAAOE1$IR.E.GinnaNuclearPowerPlantTEXTill'~A~.~OtWarWNIIC/ebs~$IIITlosooo2449.1-01000030FOoTheLEFMFeedWaterFlow(FFWH)wasaconstant6399KLB/Hrformostofthetimeperiodinquestion(somevariationisexpected).oLocalobservationoftheremotelylocatedLEFMHP-85BcomputerindicatedthelastprintoutwasonDecember20,1991.oDuringthetimeperiodinquestion,thePPCSstillindicatedvalidvaluesforalldatapointsusedforthecalorimetric.TheControlRoomoperatorsnotifiedthereactorengineerandreinitializedtheLEFMHP-85Bcomputer.Afterreinitialization,theLEFMHP-85BcomputerprintoutvaluesandPPCSvaluesreturnedtoex-pected/normalindications.Subsequently,calorimetricswereperformedusingboththeBartonD/PCellsandtheLEFMforFeedwaterFlowDatainput.Theobserveddifferenceincalculatedthermalpower,betweenthesetwocalorimetricswasapproximately0.154.n1C.INOPERABLESTRUCTURESgCOMPONENTS5ORSYSTEMSTHATCONTRIBUTEDTOTHEEVENT:AconstantfeedwaterflowoutputfromtheLEFMwastheprimecontributortotheevent.D.OTICSYSTEMSORSECONDARYFUNCTIONSAFFECTEDNone.E.METHODOFDISCOVERY:TheeventwasdiscoveredduringthereviewofhourlyPPCSlogsbytheCRF.<ACAOAAI$$$A<$4$l  
IIAC$ereMI$4$ILICENSEEEVENTREPORTILER)TEXTCONTINUATION U.$.IIUCLEAAAEOULATOAT COAIAIIION
/AftAOVEO0+5hO$I$0&IOAEXP>AE5~I$I$$AACILITYIIAAIEIllCOCKETIIUAWEAIEILEAIIIAACI1I~ISAOVANTIAL VOW)<~IUUAAOE1$IR.E.GinnaNuclearPowerPlantTEXTill'~A~.~OtWarWNIIC/ebs~$IIITlosooo2449.1-01000030FOoTheLEFMFeedWaterFlow(FFWH)wasaconstant6399KLB/Hrformostofthetimeperiodinquestion(somevariation isexpected).
oLocalobservation oftheremotelylocatedLEFMHP-85Bcomputerindicated thelastprintoutwasonDecember20,1991.oDuringthetimeperiodinquestion, thePPCSstillindicated validvaluesforalldatapointsusedforthecalorimetric.
TheControlRoomoperators notifiedthereactorengineerandreinitialized theLEFMHP-85Bcomputer.
Afterreinitialization, theLEFMHP-85BcomputerprintoutvaluesandPPCSvaluesreturnedtoex-pected/normal indications.
Subsequently, calorimetrics wereperformed usingboththeBartonD/PCellsandtheLEFMforFeedwater FlowDatainput.Theobserveddifference incalculated thermalpower,betweenthesetwocalorimetrics wasapproximately 0.154.n1C.INOPERABLE STRUCTURES gCOMPONENTS 5ORSYSTEMSTHATCONTRIBUTED TOTHEEVENT:Aconstantfeedwater flowoutputfromtheLEFMwastheprimecontributor totheevent.D.OTICSYSTEMSORSECONDARY FUNCTIONS AFFECTEDNone.E.METHODOFDISCOVERY:
Theeventwasdiscovered duringthereviewofhourlyPPCSlogsbytheCRF.<ACAOAAI$$$A<$4$l  


IIAC/earn~($451LICENSEEEVENTREPORT(LER)TEXTCONTINUATIONV.t.WJCltAAAEOVEATOATCOAItllttIOII/AtPAOVEOOVtNO51$0&IOA,t)tP<A55tltl5$EACIEITTIIAMEIllOOCKtTIIV~tIIItlTTAAI.IAIllANEAIII$5QMteaTiAI,MApEvISIO<M~Aot151R.E.NuclearPowerPlantTEXTllTasar~eeWnC~~JVJICAamS~$11111osooo24491-010-00040'8OPERATORACTION:Immediateoperatoractionwastonotifythereactorengineer,reinitializetheLEFMHP-85B.computerandperformadditionalcalorimetricsusingtheBartonD/PCellstoconfirmthatreactorthermalpowerwaswithinlimits.G.SAFETYSYSTEMRESPONSES:None.III.sCAUSEOP~9FPA.IMlKDIATECAUSE:ThesourceofinvaliddatatothePPCScalorimetriccalculationwasinvalidinputfromtheLEFM.INTERMEDIATECAUSES:WhentheLEFMHP-85BcomputerfaileditstoppedupdatingtheDigitalAnalog(D/A)outputcard.Therefore,theanalogoutputtoPPCSremainedun-changed.CROOTCAUSE:TheinvalidLEFMoutputwasduetotheunanticipatedfailuremodeoftheHP-85Bcomputer.ANALYSISOREVENTThiseventisbeingvoluntarilyreportedusingtheguidanceofNUREG-1022(LicenseeEventReportSystem),andSupplement'No.1toNUREG-1022.Thisreportisintendedtoalertotherutilitieswhichmayhavesimilarsystems.Thiseventisrelatedto,butdoesnotmeet,thereportingrequirementsof10CFR50.73,item(a)(2)(i)(B)whichrequiresreportingof"anyoperationorconditionprohibitedbytheplant'sTechnicalSpecifications".VACAOAIItttA>$451  
IIAC/earn~($451LICENSEEEVENTREPORT(LER)TEXTCONTINUATION V.t.WJCltAAAEOVEATOAT COAItllttIOII
/AtPAOVEOOVtNO51$0&IOA,t)tP<A55tltl5$EACIEITTIIAMEIllOOCKtTIIV~tIIItlTTAAI.IAIllANEAIII$5QMteaTiAI, MApEvISIO<M~Aot151R.E.NuclearPowerPlantTEXTllTasar~eeWnC~~JVJICAamS~$11111osooo24491-010-00040'8OPERATORACTION:Immediate operatoractionwastonotifythereactorengineer, reinitialize theLEFMHP-85B.computer andperformadditional calorimetrics usingtheBartonD/PCellstoconfirmthatreactorthermalpowerwaswithinlimits.G.SAFETYSYSTEMRESPONSES:
None.III.sCAUSEOP~9FPA.IMlKDIATE CAUSE:ThesourceofinvaliddatatothePPCScalorimetric calculation wasinvalidinputfromtheLEFM.INTERMEDIATE CAUSES:WhentheLEFMHP-85BcomputerfaileditstoppedupdatingtheDigitalAnalog(D/A)outputcard.Therefore, theanalogoutputtoPPCSremainedun-changed.CROOTCAUSE:TheinvalidLEFMoutputwasduetotheunanticipated failuremodeoftheHP-85Bcomputer.
ANALYSISOREVENTThiseventisbeingvoluntarily reportedusingtheguidanceofNUREG-1022 (Licensee EventReportSystem),andSupplement
'No.1toNUREG-1022.
Thisreportisintendedtoalertotherutilities whichmayhavesimilarsystems.Thiseventisrelatedto,butdoesnotmeet,thereporting requirements of10CFR50.73, item(a)(2)(i)(B) whichrequiresreporting of"anyoperation orcondition prohibited bytheplant'sTechnical Specifications".
VACAOAIItttA>$451  


MACivvWkl045ILICENSEEEVENTREPORTILER)TEXTCONTINUATIONU5,MUCLTAAA54ULATOAYCOWMI55IOOI/AAAAOYCOOM5W5I54&I045)tt<II55~I)I'55I'ACILITYMAMCIIIOOCIICTMUM45AITILLIIMUMOl1IIIS04UiMT<AI.~IUYIglOMM~A4515IR.E.GinnaNuclearPowerPlantTaXTWVVY~e~.YVAAAMVMIeIIC~~LUIITI.osooo2449.1-0005Qf08TheplantTechnicalSpecificationrelatedtothiseventisspecification4.1.1whichstates,"calibration,testing,andcheckingofanalogchannelandtestingoflogicchannelshallbeperformedasspecifiedinTable4.1-1".Table4.1-1describesthatthenuclearpowerrangesshallbecalibrateddaily(i.e.atleastonceper24hours)usingaHeatBalanceCalculation(i.e.calorimetric).'hePlantOperatingReviewCommitteedeterminedthattheintenttoperformtherequiredTechnicalSpecificationdailycalibrationoftheNuclearPowerRanges,usingtheDailyHeatBalancecalculation,wasmet,buttheHeatBalanceCalculationswereinvalidduetotheinvalidLEFMinputdata.Insummary,it'asdeterminedthatwhilethedailyheatbalancecalculationswerenotvalid,'duetothesteadystatepowermaintainedduringtheperiod,theNuclearPowerRangescontinuedtobewithindesigntolerancesandwerecapableofperformingtheirintendedfunctions.AnassessmentwasperformedconsideringboththesafetyconsequencesandimplicationsofthiseventanditwasconcludedthattherewerenooperationalorsafetyconsequencesorimplicationsattributedtotheinvalidLEFMinputtotheHeatBalanceCalculationbecause:Duringtheperiodinquestion,thehighestrecordedtotalfeedwaterflow(fromtheMainControlBoardFeedflowTransmittersasrecordedontheHeatBalanceCalculationForm)was6497.29KLB/Hr.Usingthisfeedflowresultedinacalculatedreactorthermalpowerofapproximately98.74.PrevioustotheLEFMHP-85B'computerfailure,reactorpowerasindicatedfromplantcalorimetricshadbeenlimitedtoamaximumofapproximately984powerduetodegradationinsecondarysideperformance.Therefore,reactorthermalpowerwasbelow100%forallcalculatedheatbalances.~eACAOAM544Ai54$I  
MACivvWkl045ILICENSEEEVENTREPORTILER)TEXTCONTINUATION U5,MUCLTAAA54ULATOAY COWMI55IOOI
/AAAAOYCOOM5W5I54&I045)tt<II55
~I)I'55I'ACILITY MAMCIIIOOCIICTMUM45AITILLIIMUMOl1IIIS04UiMT<AI.~IUYIglOMM~A4515IR.E.GinnaNuclearPowerPlantTaXTWVVY~e~.YVAAAMVMIeIIC~~LUIITI.osooo2449.1-0005Qf08TheplantTechnical Specification relatedtothiseventisspecification 4.1.1whichstates,"calibration, testing,andcheckingofanalogchannelandtestingoflogicchannelshallbeperformed asspecified inTable4.1-1".Table4.1-1describes thatthenuclearpowerrangesshallbecalibrated daily(i.e.atleastonceper24hours)usingaHeatBalanceCalculation (i.e.calorimetric).
'hePlantOperating ReviewCommittee determined thattheintenttoperformtherequiredTechnical Specification dailycalibration oftheNuclearPowerRanges,usingtheDailyHeatBalancecalculation, wasmet,buttheHeatBalanceCalculations wereinvalidduetotheinvalidLEFMinputdata.Insummary,it'asdetermined thatwhilethedailyheatbalancecalculations werenotvalid,'duetothesteadystatepowermaintained duringtheperiod,theNuclearPowerRangescontinued tobewithindesigntolerances andwerecapableofperforming theirintendedfunctions.
Anassessment wasperformed considering boththesafetyconsequences andimplications ofthiseventanditwasconcluded thattherewerenooperational orsafetyconsequences orimplications attributed totheinvalidLEFMinputtotheHeatBalanceCalculation because:Duringtheperiodinquestion, thehighestrecordedtotalfeedwater flow(fromtheMainControlBoardFeedflowTransmitters asrecordedontheHeatBalanceCalculation Form)was6497.29KLB/Hr.Usingthisfeedflowresultedinacalculated reactorthermalpowerofapproximately 98.74.PrevioustotheLEFMHP-85B'computer failure,reactorpowerasindicated fromplantcalorimetrics hadbeenlimitedtoamaximumofapproximately 984powerduetodegradation insecondary sideperformance.
Therefore, reactorthermalpowerwasbelow100%forallcalculated heatbalances.
~eACAOAM544Ai54$I  


IIACSetto~ITSILICENSEEEVENTREPORTILERITEXTCONTINUATIONVS.MVCLSAIIAIOVL*SOAYCOSSMINIOMASSAOYKOOMSNOIISOW104SISS(AE5SINAI'SSfACII.ICYISASSIIIIOOCIIlYIIVl&lAQlLIAMLAQIAI~IvSAASSOVSMTtALASYOIOHMAUA~AOIISIR.E.NuclearPowerPlant'fQPllY~~4~.~r400onVIIIICAeltl~'SlIIIIosooo2449101000060'8oThelowestcalculatedreactorthermalpowerusingtheinvalidLEFMinputwas97.274.Thehighestthatreactorthermalpowerwasestimatedtobewas98%.Basedontheseindications,theNuclearPowerRangescouldhavebeencalibratedasmuchas.74low.Theaccuracyofthereactorthermalpower'calculationisdeterminedtobe+2.0%.Therefore,theNuclearPowerRangeswerecalibratedtowithintheaccuracyofthereactorthermalpowercalculationandtheNuclearPowerRange"tripswouldhaveactuatedwithintheirdesigntolerance.Basedontheabove,theconclusionwasthatthepublic'shealthandsafetywasassuredatalltimes.AnevaluationwasperformedtodetermineappropriatemeanstodetectaninvalidLEFMinputtotheReactorThermalPowerCalculation.Thefollowingconclusionswerereached:00Reactorpowerwassteadystateduringthetimeinquestion(i.e.approximately10days)andallcontrolboardindicationsremainedapproximatelythesame.WhentheLEFMHP-85Bcomputerfailed,theoutputtoPPCSfailed"asis",'asopposedtoafailurethatwouldregisterinanexpectedobviousextrememode.00This.failuremode.wasnotanticipatedbytheLEFM''vendor.Asaresult,verificationfunctionsandassociatedalarmsforthisfailuremode.werenotincludedinthesystemdesign.InadditiontotheLEFMvendor,plantstaffdidnotanticipatethisfailuremode.Asa'result,theawarenesslevelforaproblemofthistypewaslowandtheformalprocessestodetectandrespondtothisconditionwerenotinplace.AlthoughspecificprocedureguidancewasprovidedtoverifyLEFMaccuracy,verifyingoperabilityoftheLEFMHP-85BcomputerpriortoperformingtheReactorThermalPowerCalculationwasnotrequired.MACSOAM~lt4ll  
IIACSetto~ITSILICENSEEEVENTREPORTILERITEXTCONTINUATION VS.MVCLSAIIAIOVL*SOAY COSSMINIOM ASSAOYKOOMSNOIISOW104SISS(AE5SINAI'SSfACII.ICYISASSIIIIOOCIIlYIIVl&lAQlLIAMLAQIAI~IvSAASSOVSMTtAL ASYOIOHMAUA~AOIISIR.E.NuclearPowerPlant'fQPllY~~4~.~r400onVIIIICAeltl~'SlIIIIosooo2449101000060'8oThelowestcalculated reactorthermalpowerusingtheinvalidLEFMinputwas97.274.Thehighestthatreactorthermalpowerwasestimated tobewas98%.Basedontheseindications, theNuclearPowerRangescouldhavebeencalibrated asmuchas.74low.Theaccuracyofthereactorthermalpower'calculation isdetermined tobe+2.0%.Therefore, theNuclearPowerRangeswerecalibrated towithintheaccuracyofthereactorthermalpowercalculation andtheNuclearPowerRange"tripswouldhaveactuatedwithintheirdesigntolerance.
Basedontheabove,theconclusion wasthatthepublic'shealthandsafetywasassuredatalltimes.Anevaluation wasperformed todetermine appropriate meanstodetectaninvalidLEFMinputtotheReactorThermalPowerCalculation.
Thefollowing conclusions werereached:00Reactorpowerwassteadystateduringthetimeinquestion(i.e.approximately 10days)andallcontrolboardindications remainedapproximately thesame.WhentheLEFMHP-85Bcomputerfailed,theoutputtoPPCSfailed"asis",'asopposedtoafailurethatwouldregisterinanexpectedobviousextrememode.00This.failuremode.wasnotanticipated bytheLEFM''vendor.Asaresult,verification functions andassociated alarmsforthisfailuremode.werenotincludedinthesystemdesign.InadditiontotheLEFMvendor,plantstaffdidnotanticipate thisfailuremode.Asa'result,theawareness levelforaproblemofthistypewaslowandtheformalprocesses todetectandrespondtothiscondition werenotinplace.Althoughspecificprocedure guidancewasprovidedtoverifyLEFMaccuracy, verifying operability oftheLEFMHP-85Bcomputerpriortoperforming theReactorThermalPowerCalculation wasnotrequired.
MACSOAM~lt4ll  


IIACSVfff~(545IuCENSEEBIENTREPORTILERITEXTCONTINUATIONU.l,IIUCL5*AAl4ULATOAYCOMMISSIOIIIASSAOY5OOvlVO5150&1045>et1A55~I5I55SACILITYNAMSIllOOCKSTIIUS%511ITILlllIIUM454IllS~CIUSffTfALVVAIflV4lOVVVAJA45I51R.E.GinnaNuclearPowerPlantTTI(TIITfffVSMASS~fSSffSSAffvSSSffVfVJVACAfffff~$111710500024491-010-0007o~08CORRECTIVEACTIONAACTIONTAKENTORETURNAFFECTEDSYSTEMSTOPRE-EVENTNORMALSTATUS:oTheLEFMHP-85BComputerwasreinitializedandtheLEFMprintoutandPPCSvaluesreturnedtoexpectednormalindications.oAllsubsequentcalorimetricswereperformedusingtheBartonD/PCellsandtheNuclearPowerRangeswereadjustedasrequired.oAnotewasaddedtothePlanOfTheDay(POD)toinstructtheControlRoomOperators,tousetheBartonD/Pcellsdataforcalorimetrics'untilfurthernotice.BACTIONTAKENORPLANNEDTOPREVENTRECUEGUBTCE:ThefollowingcorrectiveactionshavebeentakentoassurevaliddatafromtheLEFMpriortoitsuseinaPPCSreactorthermalpowercalculation(i.e.calori-metric).oAnindicationoffailureof,theLEFMinputtothePPCSis-thattheLEFMConfidenceLevel(FFWCL)willapproach1004indicatingtheLEFMoutputisnotchanging.AhighalarmonPPCSforFFWCLhasbeenaddedtoindicatethatthisfailurehasoccurred.Ifthisalarmactivates,theLEFMwillnotbeused.OperatingProcedures0-6.3(MaximumUnitPower)and0-6.3.2(MaximumUnitPowerCalculationUsingTheLEFMForFlowMeasurement)havebeenrevisedtoincludethefollowingrequirementspriortousingtheLEFMforacalorimetric:1.VerifyingthattheLEFMHP-85Bcomputerisupdatingandhasbeenoperatingforatleast10minutes.ThisensuresthecurrentvaluefortheLEFMinthePPCSisnotfailed.VACSCAMSSSA1545l  
IIACSVfff~(545IuCENSEEBIENTREPORTILERITEXTCONTINUATION U.l,IIUCL5*AAl4ULATOAY COMMISSIOII IASSAOY5OOvlVO5150&1045>et1A55~I5I55SACILITYNAMSIllOOCKSTIIUS%511ITILlllIIUM454IllS~CIUSffTfALVVAIflV4lOVVVAJA45I51R.E.GinnaNuclearPowerPlantTTI(TIITfffVSMASS~fSSffSSAffvSSSffVfVJVACAfffff~$111710500024491-010-0007o~08CORRECTIVE ACTIONAACTIONTAKENTORETURNAFFECTEDSYSTEMSTOPRE-EVENT NORMALSTATUS:oTheLEFMHP-85BComputerwasreinitialized andtheLEFMprintoutandPPCSvaluesreturnedtoexpectednormalindications.
oAllsubsequent calorimetrics wereperformed usingtheBartonD/PCellsandtheNuclearPowerRangeswereadjustedasrequired.
oAnotewasaddedtothePlanOfTheDay(POD)toinstructtheControlRoomOperators,to usetheBartonD/Pcellsdataforcalorimetrics
'untilfurthernotice.BACTIONTAKENORPLANNEDTOPREVENTRECUEGUBTCE:
Thefollowing corrective actionshavebeentakentoassurevaliddatafromtheLEFMpriortoitsuseinaPPCSreactorthermalpowercalculation (i.e.calori-metric).oAnindication offailureof,theLEFMinputtothePPCSis-thattheLEFMConfidence Level(FFWCL)willapproach1004indicating theLEFMoutputisnotchanging.
AhighalarmonPPCSforFFWCLhasbeenaddedtoindicatethatthisfailurehasoccurred.
Ifthisalarmactivates, theLEFMwillnotbeused.Operating Procedures 0-6.3(MaximumUnitPower)and0-6.3.2(MaximumUnitPowerCalculation UsingTheLEFMForFlowMeasurement) havebeenrevisedtoincludethefollowing requirements priortousingtheLEFMforacalorimetric:
1.Verifying thattheLEFMHP-85Bcomputerisupdatingandhasbeenoperating foratleast10minutes.ThisensuresthecurrentvaluefortheLEFMinthePPCSisnotfailed.VACSCAMSSSA1545l  


NACTeeM($CSIuCENSEEEVENTREPORT(LER)TEXTCONTINUATIONU,S.NUCLSANNSOULATOAVCOMMISSIONAJfAOVKOOUIVO)ISOAIOISXrlASSIISI%$FACILITYNANSIllOOCKSTNULICCNITIL$1NlA&$1I~IStauevTsALv1V1lONAAOCillR.E.GinnaNuclearPowerPlant:TtxTIN~Nrrr~NrvrNI.wrrrrrewNrcINrr~'elIInosooo24491-010-0008<<082.VerifyingthattheLEFMconfidencelevelisnotinalarm(FFWCL>99;504andFFWCL99.904).ThisensuresthattheLEFMisoperatingproperly.0Anidentificationandevaluationprocessfocusingonotherplantsystemsthatmaybesusceptibletothistypeoffailuremodeisinprogress.ADDITIONALINFORMATIONAFAILEDCOMPONENTS:TheLEFMsystemwassuppliedbyWestinghouseElectricCorporation,ModelgLEFM-824,SerialgU001.ThespecificcomponentthatfailedwastheHP-85BcomputerwithI/OROM,Serialg2619A53804.BPREVIOUSLERsONSIMILAREVENTS:AsimilarLEReventhistoricalsearchwasconductedwiththefollowingresults:NodocumentationofsimilarLEReventswithanundeterminedrootcausecouldbeidentified.C.SPECIALCOMMBFIS:Duetotheunanticipatednatureofthecomputerfailure,theindustrywillbenotifiedviaNuclearNetwork.vrC101ilSCCA<$44l}}
NACTeeM($CSIuCENSEEEVENTREPORT(LER)TEXTCONTINUATION U,S.NUCLSANNSOULATOAV COMMISSION AJfAOVKOOUIVO)ISOAIOISXrlASSIISI%$FACILITYNANSIllOOCKSTNULICCNITIL$1NlA&$1I~IStauevTsAL v1V1lONAAOCillR.E.GinnaNuclearPowerPlant:TtxTIN~Nrrr~NrvrNI.wrrrrrewNrcINrr~'elIInosooo24491-010-0008<<082.Verifying thattheLEFMconfidence levelisnotinalarm(FFWCL>99;504andFFWCL99.904).ThisensuresthattheLEFMisoperating properly.
0Anidentification andevaluation processfocusingonotherplantsystemsthatmaybesusceptible tothistypeoffailuremodeisinprogress.
ADDITIONAL INFORMATION AFAILEDCOMPONENTS:
TheLEFMsystemwassuppliedbyWestinghouse ElectricCorporation, ModelgLEFM-824, SerialgU001.Thespecificcomponent thatfailedwastheHP-85BcomputerwithI/OROM,Serialg2619A53804.
BPREVIOUSLERsONSIMILAREVENTS:AsimilarLEReventhistorical searchwasconducted withthefollowing results:Nodocumentation ofsimilarLEReventswithanundetermined rootcausecouldbeidentified.
C.SPECIALCOMMBFIS:
Duetotheunanticipated natureofthecomputerfailure,theindustrywillbenotifiedviaNuclearNetwork.vrC101ilSCCA<$44l}}

Revision as of 13:09, 29 June 2018

LER 91-010-00:on 911230,during Operator Review of Plant Process Computer Logs,Util Discovered That Invalid Data Had Been Used for Calculation.Caused by Invalid Input from Lefm.Lefm HP-85B Computer Was reinitialized.W/920129 Ltr
ML17262A741
Person / Time
Site: Ginna Constellation icon.png
Issue date: 01/29/1992
From: BACKUS W H, MECREDY R C
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LER-91-010, LER-91-10, NUDOCS 9202060130
Download: ML17262A741 (20)


Text

ACCELERATED DTIUBUTION DEMONSTIONSYSTEMk~"REGULATORY INFORMATION DISTRIBUTION SYSTEM(RIDS)'CCESSION NBR:9202060130 DOC.DATE:

92/01/29NOTARIZED:

NOFACIL:50-244 RobertEmmetGinnaNuclearPlant,Unit1,Rochester GAUTH.NAMEAUTHORAFFILIATION BACKUS,W.H.

Rochester Gas6ElectricCorp.MECREDY,R.C.

Rochester Gas6ElectricCorp.RECIP.NAME RECIPIENT AFFILIATION DOCKET05000244R

SUBJECT:

LER91-010-00:on 911230,during operatorreviewofplant,processcomputerlogs,utildiscovered thatinvaliddatahadbeenusedforcalculation.

CausedbyinvalidinputfromLEFM.LEFM HP-85BComputerwasreinitialized.W/920129 ltr.DISTRIBUTION CODE:IE22TCOPIESRECEIVED:LTR ENCLSIZE:.TITLE:50.73/50.9 Licensee"Event Report(LER),IncidentRpt,etc.NOTES:License Expdateinaccordance withloCFR2,2.109(9/19/72).

DS05000244ADRECIPIENT IDCODE/NAME PD1-3LAJOHNSON,A INTERNAL:

ACNWAEOD/DSP/TPAB NRR/DET/ECMB 9HNRR/DLPQ/LHFB10 NRR/DOEA/OEAB NRR/DST/SELB SDNRR/D~SJS LB.SDlRE-'CE2RGNIL01EXTERNALEGGGBRYCEgJ~HNRCPDRNSICPOORE,W.COPIESLTTRENCL11.11221=;111111111111111331"111,RECIPIENT IDCODE/NAME PD1-3PDAEOD/DOAAEOD/ROAB/DS PNRR/DET/EMEB 7ENRR/DLPQ/LPEB10 NRR/DREP/PRPB11 NRR/DST/SICBSH3 NRR/DST/SRXB SERES/DSIR/EIBLSTLOBBYWARDNSICMURPHY,G.A NUDOCSFULLTXTCOPIESLTTRENCL111122111122111111111111DQ~~opgys7>//~

7DNOTETOALL"RIDS"RECIPIENTS:

PLEASEHELPUSTOREDUCEiVASTE!CONTACTTHEDOCUMENTCONTROLDESK,ROOMP1-37(EXT.20079)TOELIMINATE YOURNAMEFROMDISTRIBUTION LISTSFORDOCUMENTS YOUDON'TNEED!DDSFULLTEXTCONVERSION'REQUIRED TOTALNUMBEROFCOPIESREQUIRED:

LTTR31ENCL31

"JncC'OCHESTER GASANDELECTRICCORPORATION 0I~II~I~44rTOOK11KTC~89EASTAVENUE,ROCHESTER N.K14649-0001 ROBERTC.MECREDYVicePresident CinnaNuclearProduction TELEPttONE AAEACODE7165462700January29,1992U.S.NuclearRegulatory Commission DocumentControlDeskWashington, DC20555

Subject:

'nLER91-010,DuringOperatorReviewofPlantProcessComputerLogs,ItWasDiscovered ThatInvalidDataHadBeenUsedForCalorimetric Calculation R.E.GinnaNuclearPowerPlantDocketNo.50-244Thiseventisbeingvoluntarily reportedusingtheguidanceofNUREG-1022 (Licensee EventReportSystem),andSupplement No.1toNUREG-1022.

Thisreportisintendedtoalertotherutilities whichmayhavesimilarsystems.Thiseventisrelatedto,butdoesnotmeet,thereporting requirements of10CFR50.73, item(a)(2)(i)(B).Item(a)(2)(i)(B)requiresreporting of"anyoperation orcondition prohibited bytheplant'sTechnical Specifications".

TheattachedLicenseeEventReportLER91-010isherebyvoluntarily submitted.

Thiseventhasinnowayaffectedthepublic'shealthandsafety.Verytrulyyours,xc4RobertC.MecredyU.S.NuclearRegulatory Commission RegionI475Allendale RoadKingofPrussia,PA19406GinnaUSNRCSeniorResidentInspector

~~Pi~Lri30V3c.)9202060130 920129PDRADOCK050002448PDRgpg 0

>>ACy>><<SOOIO4$)LICENSEEEVENTREPORT(LERlUWNUCLSA11IOULATOA1 COO<<)~ONAtyNOTIOONSNO.$1IO0IOVIXSYASII/SvssyACILITYNAA)aIllR.E.GinnaNuclearPowerPlantOOCXSTNV<<tallQlAo6oo0244>0)08<<II)4DuringOperaorReviewofPlantProcessComputerLogs,ItWasDiscovered ThatInvalidDataHadBenUimetr'TINTOATSISILSNNU<<SINIIIAIAOAToATI1)IOTHI1IACILITIIS INYOLVIONlNO>>THOAYTIAIIYIA1)I0VI>>1IAL"'VNJOVHV>>IIA-.I'WaasIA OAYTtA1yAO4TTHAH)AOOCXITNVNSIAISI 060001230911010000199206000OAIAATINO

<<OOINI~ONI1LavtL09"a+g)~ig@i.'HISAlyOATNSUSINTTIO yVASVANTT)OAO)I~ISO.NN41IIIIISOANNIllllll SO.AOS4IIIII<<)$0AOS41))lr>>l$OAN4)ll)ly)$0.AOOINStoa4II)l

~OMNIQI~O.T$4lallt~O.T$4)Q)lalSOI$4)QII<<I~O.T$4)QIIN)~O.T$41llIlylSO.T$4)QlNIIIO.T$4)0II>>XIIAI~O.T$4)QII<<IINI

~O.T$4)QIlaI0THtAIOVIAININTS OyISCSAf:ICA>>e>>VW>>A>>ey<<A~lllTL1)4)X'oTHa1ISA>>>>y4~A>>A>>AAOIArAAL>>1CsaESSA)LICINIIICONTACTSONTHNLail0$)NAUIWesleyH.BackusANIACOOSTechnical Assistant totherationsManaer315CO<<yLITIONILINIIOAIACHCO<<AONSNT SAILV1lOIICAI~IOINTHN1tyOAT11$)TSLtyHONI NVHSIIICAVSISTSTINCOUAONINT UANUI'ACTVNI1IAONTASLlTONy10$Rh'I'.Pri Ig<qg&I>

ggi9%j)'..gpssCAUIISTITSLICO<<yONINT NANUSACTUNI1lyONTASLTONyAOSwjv{IN+Jv wg@4i-..)(;Q>~b)<

XI0W12'0Nyg~t)4pge~%A"'o'~<V~~

~UyyLII4INTAL AITOATIXylCTIO114Ttlory>>,y>>AA>>>>sxyscrsosvsa>>ss)o>>

oArslNOASSTAACTILAA>>>>WO>>>>>>,I1,AA>>su>>vary Nf>>AA<<V>>~rITA>>>>N>>AAA>>llit)tXAICTIOLVSLVSSION OATSIIIIVONTHCAYTIA1OnDecember30,1991atapproximately 1830EST,withthereactoratapproximately 984fullpower,theControlRoomForeman,whileperforming areviewofthehourlyPlantProcessComputerSystem(PPCS)logs,determined thattheLeadingEdgeFlowMeter(LEFM}datausedbythePPCStocalculate calorimetrics, wasinvalidfrom1800EST,December20,1991toapproximately 1830EST,December.30,1991.Thiseventisbeingvoluntarily reportedtoalertotherutilities whichmayhavesimilarsystems.TheControlRoomoperators notifiedthereactorengineerandreinitialized theLEFMcomputer.

Afterreinitialization, theLEFMprintoutvaluesandPPCSvaluesreturnedtoexpected/normal indications.

Corrective actionsincluderevi'sions totheaffectedprocedures torequirecheckingtheoperation oftheLEFMpriortoperforming calorimetrics andtheadditionofahigh'alarm onPPCSindicating afailuremayhaveoccurred.

Theimmediate causewasidentified asafailureoftheLEFMHP-85Bcomputer.

>>1CI>>>>SOSISO$1

IIACleesWAI$4$ILICENSEEEVENTREPORTILER)TEXTCONTINUATION U$,ISUOLSAAASOULAToAv coeeMISCIbll SASSAOV$0OM$IlO$1$0%104$SSIA$5~I)I1$SACILITYIIAMCIIIOOCKlTIIUI&SAl1ILlAIIUSSOSII I~ISIOVSIITIAL~IM1VISIOMMe~AO$1$IR.E.NuclearPower,PlantTSITIls~~sIeeweelvee~lVACSese~$IIIllosooo2449.1-010-00020FO8PRE-EVENT PLANTCONDITIONS Theplantwasatapproximately 98%steadystatereactorpowerwithnomajoractivities inprogress.

TheControlRoomForeman(CRF)wasreviewing thehourlyPlantProcessComputerSystem.(PPCS)logs.DESCRIPTION OF-EVENTA.DATESANDAPPROXIMATE TIMESOFMAZOROCCURRENCES:

oDecember20,1991,1800EST:Eventdateandapproximate time.oDecember30,1991,1830EST:Discovery dateandapproximate time.oDecember30,1991,2055EST:Performed calori-metricusingBartonD/Pcellsoptionandplantthermalpowerwasdetermined tobeapproximately thesameasthatcalculated usingtheLeadingEdgeFlow'eter (LEFM)option.B.EVENT:OnDecember30,1991atapproximately 1830EST,withthereactoratapproximately 98%fullpower,theCRF,whileperforming areviewofthehourlyPPCSlogs,determined thattheLEFMdatausedbythePPCStocalculate calorimetrics, wasinvalidfrom1800EST,December20,1991toapproximately 1830'EST, December30,1991.Thisdetermination wasbasedonthefollowing information:

oTheLEFMFeedwater (FW)Flowconfidence levelwas100.0%formostofthetimeperiodinquestion(Ztshouldbelessthan100%andsomevariation isexpected).

~IACsOAes$$SAI$4$l

IIAC$ereMI$4$ILICENSEEEVENTREPORTILER)TEXTCONTINUATION U.$.IIUCLEAAAEOULATOAT COAIAIIION

/AftAOVEO0+5hO$I$0&IOAEXP>AE5~I$I$$AACILITYIIAAIEIllCOCKETIIUAWEAIEILEAIIIAACI1I~ISAOVANTIAL VOW)<~IUUAAOE1$IR.E.GinnaNuclearPowerPlantTEXTill'~A~.~OtWarWNIIC/ebs~$IIITlosooo2449.1-01000030FOoTheLEFMFeedWaterFlow(FFWH)wasaconstant6399KLB/Hrformostofthetimeperiodinquestion(somevariation isexpected).

oLocalobservation oftheremotelylocatedLEFMHP-85Bcomputerindicated thelastprintoutwasonDecember20,1991.oDuringthetimeperiodinquestion, thePPCSstillindicated validvaluesforalldatapointsusedforthecalorimetric.

TheControlRoomoperators notifiedthereactorengineerandreinitialized theLEFMHP-85Bcomputer.

Afterreinitialization, theLEFMHP-85BcomputerprintoutvaluesandPPCSvaluesreturnedtoex-pected/normal indications.

Subsequently, calorimetrics wereperformed usingboththeBartonD/PCellsandtheLEFMforFeedwater FlowDatainput.Theobserveddifference incalculated thermalpower,betweenthesetwocalorimetrics wasapproximately 0.154.n1C.INOPERABLE STRUCTURES gCOMPONENTS 5ORSYSTEMSTHATCONTRIBUTED TOTHEEVENT:Aconstantfeedwater flowoutputfromtheLEFMwastheprimecontributor totheevent.D.OTICSYSTEMSORSECONDARY FUNCTIONS AFFECTEDNone.E.METHODOFDISCOVERY:

Theeventwasdiscovered duringthereviewofhourlyPPCSlogsbytheCRF.<ACAOAAI$$$A<$4$l

IIAC/earn~($451LICENSEEEVENTREPORT(LER)TEXTCONTINUATION V.t.WJCltAAAEOVEATOAT COAItllttIOII

/AtPAOVEOOVtNO51$0&IOA,t)tP<A55tltl5$EACIEITTIIAMEIllOOCKtTIIV~tIIItlTTAAI.IAIllANEAIII$5QMteaTiAI, MApEvISIO<M~Aot151R.E.NuclearPowerPlantTEXTllTasar~eeWnC~~JVJICAamS~$11111osooo24491-010-00040'8OPERATORACTION:Immediate operatoractionwastonotifythereactorengineer, reinitialize theLEFMHP-85B.computer andperformadditional calorimetrics usingtheBartonD/PCellstoconfirmthatreactorthermalpowerwaswithinlimits.G.SAFETYSYSTEMRESPONSES:

None.III.sCAUSEOP~9FPA.IMlKDIATE CAUSE:ThesourceofinvaliddatatothePPCScalorimetric calculation wasinvalidinputfromtheLEFM.INTERMEDIATE CAUSES:WhentheLEFMHP-85BcomputerfaileditstoppedupdatingtheDigitalAnalog(D/A)outputcard.Therefore, theanalogoutputtoPPCSremainedun-changed.CROOTCAUSE:TheinvalidLEFMoutputwasduetotheunanticipated failuremodeoftheHP-85Bcomputer.

ANALYSISOREVENTThiseventisbeingvoluntarily reportedusingtheguidanceofNUREG-1022 (Licensee EventReportSystem),andSupplement

'No.1toNUREG-1022.

Thisreportisintendedtoalertotherutilities whichmayhavesimilarsystems.Thiseventisrelatedto,butdoesnotmeet,thereporting requirements of10CFR50.73, item(a)(2)(i)(B) whichrequiresreporting of"anyoperation orcondition prohibited bytheplant'sTechnical Specifications".

VACAOAIItttA>$451

MACivvWkl045ILICENSEEEVENTREPORTILER)TEXTCONTINUATION U5,MUCLTAAA54ULATOAY COWMI55IOOI

/AAAAOYCOOM5W5I54&I045)tt<II55

~I)I'55I'ACILITY MAMCIIIOOCIICTMUM45AITILLIIMUMOl1IIIS04UiMT<AI.~IUYIglOMM~A4515IR.E.GinnaNuclearPowerPlantTaXTWVVY~e~.YVAAAMVMIeIIC~~LUIITI.osooo2449.1-0005Qf08TheplantTechnical Specification relatedtothiseventisspecification 4.1.1whichstates,"calibration, testing,andcheckingofanalogchannelandtestingoflogicchannelshallbeperformed asspecified inTable4.1-1".Table4.1-1describes thatthenuclearpowerrangesshallbecalibrated daily(i.e.atleastonceper24hours)usingaHeatBalanceCalculation (i.e.calorimetric).

'hePlantOperating ReviewCommittee determined thattheintenttoperformtherequiredTechnical Specification dailycalibration oftheNuclearPowerRanges,usingtheDailyHeatBalancecalculation, wasmet,buttheHeatBalanceCalculations wereinvalidduetotheinvalidLEFMinputdata.Insummary,it'asdetermined thatwhilethedailyheatbalancecalculations werenotvalid,'duetothesteadystatepowermaintained duringtheperiod,theNuclearPowerRangescontinued tobewithindesigntolerances andwerecapableofperforming theirintendedfunctions.

Anassessment wasperformed considering boththesafetyconsequences andimplications ofthiseventanditwasconcluded thattherewerenooperational orsafetyconsequences orimplications attributed totheinvalidLEFMinputtotheHeatBalanceCalculation because:Duringtheperiodinquestion, thehighestrecordedtotalfeedwater flow(fromtheMainControlBoardFeedflowTransmitters asrecordedontheHeatBalanceCalculation Form)was6497.29KLB/Hr.Usingthisfeedflowresultedinacalculated reactorthermalpowerofapproximately 98.74.PrevioustotheLEFMHP-85B'computer failure,reactorpowerasindicated fromplantcalorimetrics hadbeenlimitedtoamaximumofapproximately 984powerduetodegradation insecondary sideperformance.

Therefore, reactorthermalpowerwasbelow100%forallcalculated heatbalances.

~eACAOAM544Ai54$I

IIACSetto~ITSILICENSEEEVENTREPORTILERITEXTCONTINUATION VS.MVCLSAIIAIOVL*SOAY COSSMINIOM ASSAOYKOOMSNOIISOW104SISS(AE5SINAI'SSfACII.ICYISASSIIIIOOCIIlYIIVl&lAQlLIAMLAQIAI~IvSAASSOVSMTtAL ASYOIOHMAUA~AOIISIR.E.NuclearPowerPlant'fQPllY~~4~.~r400onVIIIICAeltl~'SlIIIIosooo2449101000060'8oThelowestcalculated reactorthermalpowerusingtheinvalidLEFMinputwas97.274.Thehighestthatreactorthermalpowerwasestimated tobewas98%.Basedontheseindications, theNuclearPowerRangescouldhavebeencalibrated asmuchas.74low.Theaccuracyofthereactorthermalpower'calculation isdetermined tobe+2.0%.Therefore, theNuclearPowerRangeswerecalibrated towithintheaccuracyofthereactorthermalpowercalculation andtheNuclearPowerRange"tripswouldhaveactuatedwithintheirdesigntolerance.

Basedontheabove,theconclusion wasthatthepublic'shealthandsafetywasassuredatalltimes.Anevaluation wasperformed todetermine appropriate meanstodetectaninvalidLEFMinputtotheReactorThermalPowerCalculation.

Thefollowing conclusions werereached:00Reactorpowerwassteadystateduringthetimeinquestion(i.e.approximately 10days)andallcontrolboardindications remainedapproximately thesame.WhentheLEFMHP-85Bcomputerfailed,theoutputtoPPCSfailed"asis",'asopposedtoafailurethatwouldregisterinanexpectedobviousextrememode.00This.failuremode.wasnotanticipated bytheLEFMvendor.Asaresult,verification functions andassociated alarmsforthisfailuremode.werenotincludedinthesystemdesign.InadditiontotheLEFMvendor,plantstaffdidnotanticipate thisfailuremode.Asa'result,theawareness levelforaproblemofthistypewaslowandtheformalprocesses todetectandrespondtothiscondition werenotinplace.Althoughspecificprocedure guidancewasprovidedtoverifyLEFMaccuracy, verifying operability oftheLEFMHP-85Bcomputerpriortoperforming theReactorThermalPowerCalculation wasnotrequired.

MACSOAM~lt4ll

IIACSVfff~(545IuCENSEEBIENTREPORTILERITEXTCONTINUATION U.l,IIUCL5*AAl4ULATOAY COMMISSIOII IASSAOY5OOvlVO5150&1045>et1A55~I5I55SACILITYNAMSIllOOCKSTIIUS%511ITILlllIIUM454IllS~CIUSffTfALVVAIflV4lOVVVAJA45I51R.E.GinnaNuclearPowerPlantTTI(TIITfffVSMASS~fSSffSSAffvSSSffVfVJVACAfffff~$111710500024491-010-0007o~08CORRECTIVE ACTIONAACTIONTAKENTORETURNAFFECTEDSYSTEMSTOPRE-EVENT NORMALSTATUS:oTheLEFMHP-85BComputerwasreinitialized andtheLEFMprintoutandPPCSvaluesreturnedtoexpectednormalindications.

oAllsubsequent calorimetrics wereperformed usingtheBartonD/PCellsandtheNuclearPowerRangeswereadjustedasrequired.

oAnotewasaddedtothePlanOfTheDay(POD)toinstructtheControlRoomOperators,to usetheBartonD/Pcellsdataforcalorimetrics

'untilfurthernotice.BACTIONTAKENORPLANNEDTOPREVENTRECUEGUBTCE:

Thefollowing corrective actionshavebeentakentoassurevaliddatafromtheLEFMpriortoitsuseinaPPCSreactorthermalpowercalculation (i.e.calori-metric).oAnindication offailureof,theLEFMinputtothePPCSis-thattheLEFMConfidence Level(FFWCL)willapproach1004indicating theLEFMoutputisnotchanging.

AhighalarmonPPCSforFFWCLhasbeenaddedtoindicatethatthisfailurehasoccurred.

Ifthisalarmactivates, theLEFMwillnotbeused.Operating Procedures 0-6.3(MaximumUnitPower)and0-6.3.2(MaximumUnitPowerCalculation UsingTheLEFMForFlowMeasurement) havebeenrevisedtoincludethefollowing requirements priortousingtheLEFMforacalorimetric:

1.Verifying thattheLEFMHP-85Bcomputerisupdatingandhasbeenoperating foratleast10minutes.ThisensuresthecurrentvaluefortheLEFMinthePPCSisnotfailed.VACSCAMSSSA1545l

NACTeeM($CSIuCENSEEEVENTREPORT(LER)TEXTCONTINUATION U,S.NUCLSANNSOULATOAV COMMISSION AJfAOVKOOUIVO)ISOAIOISXrlASSIISI%$FACILITYNANSIllOOCKSTNULICCNITIL$1NlA&$1I~IStauevTsAL v1V1lONAAOCillR.E.GinnaNuclearPowerPlant:TtxTIN~Nrrr~NrvrNI.wrrrrrewNrcINrr~'elIInosooo24491-010-0008<<082.Verifying thattheLEFMconfidence levelisnotinalarm(FFWCL>99;504andFFWCL99.904).ThisensuresthattheLEFMisoperating properly.

0Anidentification andevaluation processfocusingonotherplantsystemsthatmaybesusceptible tothistypeoffailuremodeisinprogress.

ADDITIONAL INFORMATION AFAILEDCOMPONENTS:

TheLEFMsystemwassuppliedbyWestinghouse ElectricCorporation, ModelgLEFM-824, SerialgU001.Thespecificcomponent thatfailedwastheHP-85BcomputerwithI/OROM,Serialg2619A53804.

BPREVIOUSLERsONSIMILAREVENTS:AsimilarLEReventhistorical searchwasconducted withthefollowing results:Nodocumentation ofsimilarLEReventswithanundetermined rootcausecouldbeidentified.

C.SPECIALCOMMBFIS:

Duetotheunanticipated natureofthecomputerfailure,theindustrywillbenotifiedviaNuclearNetwork.vrC101ilSCCA<$44l