ML17252B432: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
(9 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
| issue date = 05/07/1976 | | issue date = 05/07/1976 | ||
| title = LER 76-023-00 for Dresden 2 Regarding an Occurrence of Seven of Nine Penetrations Failed a Surveillance Test by Exhibiting Leakage | | title = LER 76-023-00 for Dresden 2 Regarding an Occurrence of Seven of Nine Penetrations Failed a Surveillance Test by Exhibiting Leakage | ||
| author name = Stephenson | | author name = Stephenson B | ||
| author affiliation = Commonwealth Edison Co | | author affiliation = Commonwealth Edison Co | ||
| addressee name = Keppler J | | addressee name = Keppler J | ||
| addressee affiliation = NRC/RGN-III | | addressee affiliation = NRC/RGN-III | ||
| docket = 05000237 | | docket = 05000237 | ||
Line 15: | Line 15: | ||
| page count = 2 | | page count = 2 | ||
}} | }} | ||
=Text= | |||
{{#Wiki_filter:v-,...* | |||
*\ | |||
Commonwealth Edison Dresden Nuc.9Power Station R.R. #1 , | |||
/. | |||
Morris, Illinois 60450 Telephone 815/942-2920 | |||
.BBS Ltr. #352-76 May 7, 1976 Mr. James G. Keppler, Regional Director Directorate of Regulatory Operations - Region I~I U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Enclosed please find Reportable Occurrence number 50-237/1976-23. | |||
This report is being submitted to your office in accordance with the Dresden Nuclear Power Station Technical Specifications, Section 6.6.B . | |||
. ~- 7 ,/ | |||
--<-?'..,,;?. | |||
~--;>'.:..' ~ | |||
~e2- | |||
-;"'.:-~ | |||
B."' B. Stephenson | |||
* Station Superintendent Dresden Nuclear Power Station BBS:smp Enclosure | |||
.cc: Director of Inspection & Enforcement Director of Management Information & Program Control File/NRC 4790 | |||
. LICENSEE EVENT REPORT | |||
....:...:: CONTROL BLOCi<:, | |||
. 1 e I I I I* I 6 | |||
.LEASE PRINT ALL REQUIRED INFORMATION] | |||
* LICENSEE *-"; LICENSE EVENT NAME LICENSE NUMBER TYPE TYPE | |||
@tl 1Il~IP17<1SI d-1 IO Io I- lo ID I 01oIo1-1OI0 I I.If I I 111 11 / I 10121 7 8 9 14 15 25 . 26 30 31 32 REPORT REPORT | |||
. | |||
* CATEGORY TYPE. SOURCE* DOCKET NUMBER EVENT DATE . REPORT OA TE | |||
@IT! CON'T I I I Lhd lhJ 101s101..:..101~13171 IOl4-IOIS 17lcPI IOISIOl7171G I 7 8 57 58 59 60 61 68 69 74 75 80 EVENT DESCRIPTION (Qig] I j)t.JR1NG- A R£FUEUtJ('y SURV1L-t..AJ,JC£ LEAK TEST (-n:c.H . .$Pc... )./..$". K. r. A) ON 7 8 9 . 80 lol31 !THE ccsw PumP Wl.lJl.--r P£NCTMT10N~, 5EvcJJ | |||
* OF THC Nt Ne P£NE:IRAT10,J~ FAtL£J) I 7 8 9 . . 80 | |||
* fol41 IBY CX.H181(1NG- J**Ef/t<.AGt-. wof.ic: ~£Qv£sr-;; WE'R. J N1T111Tt0 FoR RESE"ALIWG- TH£ I 7 8 9 80 | |||
@@] IPCM:;rRAr101>1s. uPm.J C...omPLfT10~1 oi:- REPft1RSJ1Ht--; PENETgP.T10NS vJF.E;£ RTE:~c.D AND I 7 8 9 . . 0 (QI§] EXH1B1T£D Z.Ef!O l..£AK.fl.G£. THiS IS NOT A R.,GPET/T1V Oc V R..NCC ~C>-;237 lCi?(:J-').3 7 8 9 PRIME 80 | |||
*SYSTEM CAUSE COMPONENT COMPONENT CODE CODE COMPONENT CODE SUPPLIER | |||
* MANUFACTURER VIOLATION | |||
@0 IS I FI lfil IP IE IN I£ IT IR l . Lt)J IZ I q I q ICf I tiJ 7 8 9 10 11 12 17 43 44 47 48 CAUSE DESCRIPTION | |||
@I@ I OPcRATtoAJA L \IJBRATf orJ APPA R£.IVT"L. y C.AUSC.D T1-I£ CAULK.ING- To CRF\C\<. lt-1 I 7 8 9 80 lolsl I P£NE-IRAliON.> lAJC:g£ R~t:ALCD WITH A r.1-1ABL" ~EAL£. (RTV) WHIU-f SHOUL.0 I 7 8 9 80 IT@ I PREZVf\IT f'UTvRE St:flL DSG R. flDflT1DtJ. I 7 8 9 80 FACILITY .METHOD OF | |||
- STATUS % POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION EE] | |||
7 8 9 LHJ 10 101010112 13 AJA 44 LBJ 45 46 NA 80 FORM OF ACTIVITY CONTENT 7 | |||
rn 8 RELEASED 9 | |||
lbJ OF RELEASE lZJ 10 11 I | |||
AMOUNT OF ACTIVITY NA 44 45 NA LOCATION *OF RELEASE . | |||
80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION lieJ 1010101 lbJ 7 8 9 11 12 13 80 PERSONNEL INJURIES EE 10I010 I _________N_A_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___, | |||
NUMBER DESCRIPTION 7 8 9 11 12 80 OFFSITE CONSEQUENCES | |||
.[ili] | |||
7 8 9 80 | |||
. LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION | |||
[i))_ ~. /VA 7 8 9 10 80 PUBLICITY | |||
[ill] NA 7 8 9 80 ADDITIONAL FACTORS | |||
~ NA 80 7 8 9 EE]8 ..9L-----------------------------------:~ | |||
*7 80 GPO 881 | |||
* 667}} |
Latest revision as of 12:39, 18 March 2020
ML17252B432 | |
Person / Time | |
---|---|
Site: | Dresden |
Issue date: | 05/07/1976 |
From: | Stephenson B Commonwealth Edison Co |
To: | James Keppler NRC/RGN-III |
References | |
BBS Ltr. #352-76 LER 76-023-00 | |
Download: ML17252B432 (2) | |
Text
v-,...*
- \
Commonwealth Edison Dresden Nuc.9Power Station R.R. #1 ,
/.
Morris, Illinois 60450 Telephone 815/942-2920
.BBS Ltr. #352-76 May 7, 1976 Mr. James G. Keppler, Regional Director Directorate of Regulatory Operations - Region I~I U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Enclosed please find Reportable Occurrence number 50-237/1976-23.
This report is being submitted to your office in accordance with the Dresden Nuclear Power Station Technical Specifications, Section 6.6.B .
. ~- 7 ,/
--<-?'..,,;?.
~--;>'.:..' ~
~e2-
-;"'.:-~
B."' B. Stephenson
- Station Superintendent Dresden Nuclear Power Station BBS:smp Enclosure
.cc: Director of Inspection & Enforcement Director of Management Information & Program Control File/NRC 4790
. LICENSEE EVENT REPORT
....:...:: CONTROL BLOCi<:,
. 1 e I I I I* I 6
.LEASE PRINT ALL REQUIRED INFORMATION]
- LICENSEE *-"; LICENSE EVENT NAME LICENSE NUMBER TYPE TYPE
@tl 1Il~IP17<1SI d-1 IO Io I- lo ID I 01oIo1-1OI0 I I.If I I 111 11 / I 10121 7 8 9 14 15 25 . 26 30 31 32 REPORT REPORT
.
- CATEGORY TYPE. SOURCE* DOCKET NUMBER EVENT DATE . REPORT OA TE
@IT! CON'T I I I Lhd lhJ 101s101..:..101~13171 IOl4-IOIS 17lcPI IOISIOl7171G I 7 8 57 58 59 60 61 68 69 74 75 80 EVENT DESCRIPTION (Qig] I j)t.JR1NG- A R£FUEUtJ('y SURV1L-t..AJ,JC£ LEAK TEST (-n:c.H . .$Pc... )./..$". K. r. A) ON 7 8 9 . 80 lol31 !THE ccsw PumP Wl.lJl.--r P£NCTMT10N~, 5EvcJJ
- OF THC Nt Ne P£NE:IRAT10,J~ FAtL£J) I 7 8 9 . . 80
- fol41 IBY CX.H181(1NG- J**Ef/t<.AGt-. wof.ic: ~£Qv£sr-;; WE'R. J N1T111Tt0 FoR RESE"ALIWG- TH£ I 7 8 9 80
@@] IPCM:;rRAr101>1s. uPm.J C...omPLfT10~1 oi:- REPft1RSJ1Ht--; PENETgP.T10NS vJF.E;£ RTE:~c.D AND I 7 8 9 . . 0 (QI§] EXH1B1T£D Z.Ef!O l..£AK.fl.G£. THiS IS NOT A R.,GPET/T1V Oc V R..NCC ~C>-;237 lCi?(:J-').3 7 8 9 PRIME 80
- SYSTEM CAUSE COMPONENT COMPONENT CODE CODE COMPONENT CODE SUPPLIER
- MANUFACTURER VIOLATION
@0 IS I FI lfil IP IE IN I£ IT IR l . Lt)J IZ I q I q ICf I tiJ 7 8 9 10 11 12 17 43 44 47 48 CAUSE DESCRIPTION
@I@ I OPcRATtoAJA L \IJBRATf orJ APPA R£.IVT"L. y C.AUSC.D T1-I£ CAULK.ING- To CRF\C\<. lt-1 I 7 8 9 80 lolsl I P£NE-IRAliON.> lAJC:g£ R~t:ALCD WITH A r.1-1ABL" ~EAL£. (RTV) WHIU-f SHOUL.0 I 7 8 9 80 IT@ I PREZVf\IT f'UTvRE St:flL DSG R. flDflT1DtJ. I 7 8 9 80 FACILITY .METHOD OF
- STATUS % POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION EE]
7 8 9 LHJ 10 101010112 13 AJA 44 LBJ 45 46 NA 80 FORM OF ACTIVITY CONTENT 7
rn 8 RELEASED 9
lbJ OF RELEASE lZJ 10 11 I
AMOUNT OF ACTIVITY NA 44 45 NA LOCATION *OF RELEASE .
80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION lieJ 1010101 lbJ 7 8 9 11 12 13 80 PERSONNEL INJURIES EE 10I010 I _________N_A_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___,
NUMBER DESCRIPTION 7 8 9 11 12 80 OFFSITE CONSEQUENCES
.[ili]
7 8 9 80
. LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION
[i))_ ~. /VA 7 8 9 10 80 PUBLICITY
[ill] NA 7 8 9 80 ADDITIONAL FACTORS
~ NA 80 7 8 9 EE]8 ..9L-----------------------------------:~
- 7 80 GPO 881
- 667