LER 80-030/03L-0 for Dresden Unit 3 Regarding While Reducing Power for Manual Scram Required by I.E.Bulletin 80-17, Routine Surveillance of MSIV Closure Times Showed That MSIVs 3-203-2B and 2D Closed in Less than 3 Seconds
ML17252B188
Person / Time
Site: Dresden Constellation icon.png
Issue date: 08/04/1980
From: Stephenson B
Commonwealth Edison Co
To: James Keppler
NRC/RGN-III
References
BBS LTR #80-645 LER 80-030/03L-0
Download: ML17252B188 (2)


Text

\ ...

~

e Commo9alth  ::;; -

Edison '

Dresden Nuclear Power Station R.R. #1 Morris, Illinois 60450 .

Telephone 815/942-2920 August 4, 198.b BBS LTR {/80-645 James G. Keppler, Regional Director Directorate of Regulat~ry Operations - Region III U.S. Nuclear Regulatory* Commission 799 Roosevel~ Road Glen Ellyn, IL 60137 Reportable Occurrence Report #80~30/03L-0, Docket #050~249 is

  • being submitted to your office .in accordance with *Dresden Nuclear Power Station Technical Specification 6.6.B.2.(b), conditions leading to operation in a degraded mode permitted by a limiting condition for operation or*plant shutdown. required by a limiting condition for operation.

Ow~~,.._~

B. B. ~~ei[~:son Station Superintendent Dresden Nuclear Power Station BBS:crf Enclosure cc: Director of Inspection* & Enforcement Director of Maµagement Information & Program Control U.S. NRC Document Management Branch File/NRC *Aoo'a.

s 1/r

~UG s1sso

~)

<~

  • .*j/

,.i~

CONTROL BLOCK:

._I_..____,__~__._ _.___.IQ LICENSEE EVENT REPORT :*.

--NRC FORM 366'"- -"='-:::::-=:=:::**::*=============**::.:***.:::-~-:.::--:::*: : :*=::"::::.:.::=-__:_--_-::..:::::::::*=:=::-::-.::~:*...::-~.-:*.:_-:-u; s,-'NOCLEAR- REGU'CA TORY COMMl~*ION---:::_-.:::.

W (PLEAsE PRINT OR TYPE ALL REQUIRED INFORMATIONI 1 6 .

~ Ir IL In 1 R 1s I 3 101 o Io I - Io Io Io Io Io 1-* *10 lo IG)I 4 I 1 I 1 11 I 1 101 I 10 7 8 9 LICENSEE. COOE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T CIT!] REPORT SOURCE 11 lt6\j t.::__J\_V o I s I o I* o I o I 2 I 4 I9 IG)I o 17 11 I 9 I a I o I© I o I a I o I s I a Io 10 7 s 60 61 DOCKET NUMBER 66 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION A~D PROBABLE CONSEQUENCES @

((IIJ I While reducing power for the manual scram required by I.E.Bulletin 80-17, routine surveillance of MSIV closure times showed that .MSIVs 3-203-2B and 2D closed in less

[QJI] than 3 SP.conds, exceed.i.ng T.S. Table -3. 7 .. 1 limits of 3</'=T,<1=5, secs. Safety sig*

CIT§] I nificanc:e minimized because* the inboard MSIV closure times were within limits.

[£TIJ 1..-Th_i_s_e_v_e_n_t_h_a_s_o_c_cu_r_r_e_d_s_e_v_e_r_a_l_t_im_e_s_b_e_f_o_r_e_.__s_e_e_R_._o_._7_9_-_2_0_/0_3_L_-_o_.-..,.-------~--',.

[ill]

_, [ill]

7 8 9 80 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COMPONENT Cc°DE SUBCODE SUBCODE

[ITI]'

7 8 IC ID I@*

9 10.

L!J@ LU@

11 12 Iv 13 IA IL Iv IE Ix I@

16 L.!J@)

19 w@

20 SEQUENTIAL OCCUR REN CE REPORT REVISION

. LERJRO c*VENTYEAR* REPORT NO. CODE TYPE NO.

@ NUMBERREPORT I 8 I0 I I23 I. 1° 13 1° 26I I/I 1° 13 29I ~ l=J ~

21 22 24 27 28 30 31 32.

ACTION FUTURE EFFECT SHUTDOWN (.;:;\ ATTACHMENT NPR0-4 PRIME COMP. COMPONENT TAKEN ACTION ON PLANT METHOD HOURS ~ SUBMITTED FORM :;us. SUPPLIE:c:l MANUFACTURER W@W@

33 34 W@

35 11J 36 I

37 o Io Io Io 40 I L!!J@

41 l!.J@)

42 l!Ll@

43 le 16 16 Is !@_

44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

OJ:[] I MSIV 3-203-2B timing mechanism became misadjusted from normal plant operation. Timing OJI] r*mechanism was loose on MSIV 3-203-2D. MSIV 3-203-2B was adjusted and timed at 3. 2 secs. MSIV 3-203-2D was tightened, adjusted and timed at 3 secs. The quarterly timing surveillance will continue to be performed to ensure proper closure times OJ)) 'L-~~~~~~~~~~~~----~~~~~~-=-~~~~~~---'-~~~~~~---'

are maintained.

ITEi 7 8 9 80 FACILITY ljQ\ METHOD OF ~

STATUS  % POWER OTHER STATUS \::::J DISCOVERY DISCOVERY DESCRIPTION '23;

!Im l.£J@ I 0 I 2 14 l@l....____ NA_ _~ ~G:Vl._Su_rv_e_il_l_a_n_.c_e~T_e_s_t_i_*n_g~-~~--~-~---'
7. . 8 9 10 12 1'3 44 45 46 80

. ACTIVITY CONTENT ~

RELEASED OF RELEASE AMOUNT OF ACTIVITY . LOCATION OF RELEASE @
ITTIJ 7 8

~

9

~@I 10 11 NA 44 45 NA 80

' PERSONNEL EXPOSURES *r:;;::.,

NUMBER (.;':;\TYPE DESCRIPTION CiJ:Z] jO IO JO 1'22J~@).__~~~~~NA~~~~~~~~~~~~~~~~~~~~

8 9 11 12 13 80 PERSONNEL INJURIES Q NUMBER DESCRIPTION~

G:li] IO IO JO l@)L-~~~~~~~N_A~~~~~~~~~~~~~~~~~~---1 1 a 9 11 12 ao LOSS OF OR DAMAGE TO FACILITY 143\

TYPE DESCRIPTION '.::..::J

-~ ~(§)....________~___N_A_ _ _ _ _ _ _ _ _~-----------'

8 9 10 80 PUBLICITY (.;;\ NRC USE Q ISSUEDr.:;\ DESCRIPTION~ NL y "'

CIIII lli_Je;....___ _ _ _ _ _ _ _ _ _N_A_ _ _ _ _ _ _ _ _ _ ___, I I I I I I I I I I I I I~

'. 7 8 9 10 68 69 80.;;

PHONE; _ _ 5_4_9_ _ _ _ _ _ _ __ 0 Cl.

  • - - - - - NAME OF PRE p ARE R ::::::=S=p::e::r=o=f=f::-:-:.::.::.::.::===****=====-=-=-=-===-*=-=-=..:::-=_

- - - - - - * * - - . . : . - - - - - - - - - - * - * - - - - - - --- -*-- --<