| issue date = 12/19/2016
| issue date = 12/19/2016
| title = Emergency Plan for Nuclear Facilities at Idaho State University: AGN-201M and Subcritical Assembly
| title = Emergency Plan for Nuclear Facilities at Idaho State University: AGN-201M and Subcritical Assembly
| author name = Dunzik-Gougar M L
| author name = Dunzik-Gougar M
| author affiliation = Idaho State Univ
| author affiliation = Idaho State Univ
| addressee name =  
| addressee name =  
Line 12: Line 12:
| document type = Emergency Preparedness-Emergency Plan, Letter
| document type = Emergency Preparedness-Emergency Plan, Letter
| page count = 29
| page count = 29
| revision = 0
}}
}}
=Text=
{{#Wiki_filter:Idaho State UNIVERSITY Nuclear Engineering 995 University Blvd. Idaho Falls, ID 83402 December 19, 2016 NRC Public Document Room U.S. Nuclear Energy Commission Washington, DC 20555-0001 One white Flint North Mail Stop: OWEN E13 11555 Rockville Pike Rockville, MD 20852-2738                  C: Xiaosong Yin                                        Kevin Ramsey Research and Test Reactors Br.                          Fuel Mfg. Br.
MS: 0-12 D 03                                          MS: E2-C40M
==SUBJECT:==
Emergency Plan for Nuclear Facilities at Idaho State University: AGN-201 M (License R-110, Docket No.
50-284) and Subcritical Assembly (License No. SNM-1373, Docket No. 70-1374) Redacted for Public Release Attached is a redacted version of the Emergency Plan to allow for public release, as requested by Mr. Xiaosong Yin of NRC.
Sincerely, Mary Lou Dunzik-Gouga Reactor Administrator Idaho State University Attachments:
Emergency Plan, Rev. 7 Redacted Phone: (208) 533-8114 *Fax: (208) 526-8255
                                              /SU is an Equal Oppa1tunity Employer
EMERGENCY PLAN FOR THE NUCLEAR FACILITIES AT IDAHO STATE UNIVERSITY:
AGN-201M NUCLEAR REACTOR (LICENSE NO. R-110, DOC~T NO. 50-284)
AND SUBCRITICAL ASSEMBLY (LICENSE NO. SNM-1373, DOCKET NO. 70-1374)
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006
TABLE OF CONTENTS
==1.0      INTRODUCTION==
................................................................................................... 3 2.0      DEFINITIONS ......................................................... :.............................................. 4 3.0      ORGANIZATION AND RESPONSIBILITIES ....................................................... 5 3.1    Emergency Organization ............................................................................. 5 3.2    Director of Emergency Operations (DEO) ................................................... 5 3.3    Radiation Safety and Dose Assessment Coordinator (DAC) ......................... 6 3.4    Reactor Safety and Recovery Operations Coordinator (ROC) ...................... 7 3.5    Emergency Preparedness Coordinator (EPC) ............................................... 7 3.6    On-Campus Emergency Support Organizations ........................................... 7
: 3. 7  Off-Campus Emergency Support Organizations ........................................... 8 4.0      EMERGENCY CLASSIFICATIONS ...................................................................... 9 4.1    Notification ofUnusual Events (NOUE) ...................................................... 9 5.0      EMERGENCY ACTION LEVELS .......................................................................... 9 6.0      EMERGENCY PLANNING ZONE ........................................................... :............. 9 7.0      EMERGENCY RESPONSE .................................................................................. 10 7.1    Activation of the Emergency Organization ................................................ 10 7.2    Assessment Actions ................................................................................... 10 7.3    Protective Actions ..................................................................................... 10 7.4    Corrective Actions ..................................................................................... 12 8.0      EMERGENCY FACILITES AND EQUIPMENT .................................................. 12 8.1    Emergency Support Center (ESC) ............................................................. 12 8.2    Assessment Facilities ................................................................ :................ 13 8.3    Facilities and Methods for Assisting Injured and Contaminated Personnel . 13 8.4    Emergency Communications System ......................................................... 14 9.0      RECOVERY ......................................................................................................... 14 10.0      MAINTAINING EMERGENCY PREPAREDNESS ............................................. 14 10.1  Reviews and Approvals ............................................................................. 15 10.2  Training and Drills .................................................................................... 15 10.3  Equipment Maintenance ............................................................................ 16 11.0      IMPLEMENTING PROCEDURES ....................................................................... 16 Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                                              Page 1 of26
TABLE OF CONTENTS (CONTINUED)
Figure Al.                              Cam us ............. *.............................................. 17 Figure A2.                                                        .. ............................................ 18 Figure A2.                                                        .. ............................................ 19 Figure A4.                                                        .............................................. 20 Figure A5.                                                        .. ............................................ 21 APPENDIXB.
EMERGENCY ORGANIZATION AND PERSONNEL ............................... , .................... 22 EMERGENCY NOTIFICATION ROSTER ....................................................................... 22 APPENDIXC.
EMERGENCY PROCEDURES ......................................................................................... 23 C 1. Nuclear Emergency ...................................................................................... 23 C2. Bomb Threat ................................................................................................ 23 C3. Extensive Fire or Explosion ........................................................ '. ................. 24 C4. Theft or Attempted Theft of Special Nuclear Material.. ................................. 24 C5. Report or Observation of Severe Natural Phenomena .................................... 25 C6. Evacuation Procedure ....................................... :........................................... 25 Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                                            Page 2 of26
==1.0      INTRODUCTION==
This Emergency Plan shall be used as a plan of action to follow in the event of an emergency situation at the nuclear facility located at Idaho State University, Pocatello, Idaho.
The nuclear facility consists of an AGN-201 nuclear reactor manufactured by Aerojet General Nucleonics (AGN) in 1956 and a Subcritical Assembly. The AGN reactor and Subcritical Assembly are owned by Idaho State University and operated under U.S. NRC License Nos. R-110 and SNM-1373, respectively. The reactor is li~imum power of 5 W. The fuel for both facilities consists of u r a n i u m - - - - -
* The AGN-201 reactor system consists of two basic units, the reactor and the control console.
The reactor unit includes the core consisting ofU02 uniformly dispersed in polyethylene, a graphite reflector, and the lead and water shielding. Fuel loaded control and safety rods are installed vertically from the bottom of the reactor unit. These rods pass by the nuclear instrumentation, which measures the power level. Rod movement is achieved by the use of control rod drive mechanisms that provide safe and efficient operation of the reactor. The weight .
of the reactor unit, with the water shield, is approximately 20,000 pounds; the weight of the t      t 1        1
* b t 800 I          d Th AGN-201 reactor is located in
                              '  .                      building at Idaho State University (ISU).
      '      < ~  *      "  ~ '  -!~ ~ I *
  "  .      ...          -                ~
The Subcritical A s s e m b l y -
* The Subcritical Assembly fuel consists of containing an aluminum-uranium mixture enriched to -
* The fuel lates measure                                            . The aluminum cladding is The Emergency Plan has the following purposes:
(1)      To describe provisions made through advanced planning to cope with an emergency situation not normally expected from routine operations of the nuclear facilities; and (2)      To provide assurances that appropriate measures can and will be taken to mitigate the consequences of such an emergency, should it occur, and thereby further assure the protection of the public health and safety, as well as the safety of radiation workers at
            ~~~                                                                            .
This Emergency Plan was prepared to be in compliance with ANSI/ANS-15 .16-1982, "Emergency Planning for Research Reactors," and NUREG-0849, "Standard review Plan for the review and Evaluation of Emergency Plans for Research and Test Reactors." Differences and variation of this document from those that are used for other reactor facilities realistically reflect the characteristics unique to the ISU Nuclear Facility.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                          Page 3 of26
2.0      DEFINITIONS 2.1  Emergency - An emergency is a condition that calls for immediate action, beyond the scope of normal operating procedures, to avoid an accident or mitigate the consequences of one.
2.2  Emergency Organization - The Emergency Organization consists of a Director and a team of technical coordinators who possess the detailed knowledge of the Nuclear Facilities and radiation safety to respond appropriately to any Emergency within the EPZ.
2.3  Director of Emergency Operations CDEO) - The DEO is the individual who has the responsibility of coordinating the response of the Emergency Organization to any Emergency within the EPZ.
2.4  Emergency Preparedness Coordinator (EPC) - The EPC is the individual who has the responsibility of coordinating emergency preparedness, including responsibility and authority for emergency preparedness planning, updating emergency plans and procedures, and coordinating plans with other applicable organizations.
2.5  Radiation Safety Dose Assessment Coordinator (PAC) - The DAC is the individual who has the responsibility for onsite and offsite dose assessments and recommended protective actions.
2.6  Reactor Safety Committee__(RfilJ. - The RSC consists of a group of engineers and scientists, knowledgeable in nuclear reactor matters. The RSC periodically reviews and approves all procedures related to the safe operation of the ISU AGN-201 Reactor Facility, including this Emergency Plan Document.
: 2. 7  Recovery Operations Coordinator CROC) - The ROC is the individual who has the responsibility of making recommendations to mitigate the consequences of and resolve emergencies directly involving reactor or Subcritical Assembly safety.
2~8 2.9 Emergency Planning Zone CEPZ)-        *' .            "  .  . '    ,  , ~ ., -
Emergency Support Center CESC) - The ESC serves as a coordination area for all
              - i e s for addressing the emergency.
2.10 Hold Station - During an emergency, reactor personnel will gather at the Hold Station insuring eve one is accounted for and checked for radioactive contamination 2.11 Operations Area -
2.12 Operations Boundary-2.13 Nuclear Facility - Consists of the AGN-201 nuclear reactor and the Sub critical Assembly.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                Page 4 of26
3.0      ORGANIZATION AND RESPONSIBILITIES 3.1      Emergency Organization The Emergency organization consists of a Director and a team of technical coordinators who possess a detailed knowledge of the Reactor Facility. This team is augmented with selected off-campus agencies that provide response actions normally beyond the capabilities of ISU personnel. Figure 1 shows a block diagram illustrating the structure of the Emergency Organization. Appendix B shows the Emergency Organization and its line of succession along with a current listing of personnel. Updating of Appendix B does not constitute a revision to this Emergency Plan.
Director of Emergency Operations (DEO)
Radiation Safety and Dose                          Reactor Safety and Recovery Assessment Coordinator                              Operations Coordinator (DAC)                                            (ROC)
ISU Public Safety                              Emergency Preparedness Department                                    Coordinator (EPC)
ISU Technical Safety Office i - - - - - - - 1    Reactor Operations Personnel                                          Personnel
                  . .            .      . I Figure 1. Emergency Organization for ISU Nuclear Facilities.
3.2      Director of Emergency Operations (DEO) 3.2.1    The Reactor Administrator for the ISU AGN-201M Reactor Facility shall be the Director of Emergency Operations. In the event that the Reactor Administrator is unavailable or Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                    Page 5 of26
otherwise incapacitated, the DEO shall be assumed according to the following line of succession:
Reactor Administrator Assistant Reactor Administrator Reactor Supervisor Senior Reactor Operator Onsite 3.2.2. The DEO shall be responsible for classifying the emergency and declaring a Notification of an Unusual Event (NOUE). The DEO shall be responsible for directing all elements of the Emergency Organization to effectively bring the emergency under control. This responsibility shall include the following key decisions:
(a) That specific elements of the Emergency Organization should or should not be activated based upon circumstances of the emergency, existing or imminent; (b) That sufficient control exists such that an emergency, once declared, may be terminated; (c) That recovery actions shall commence; and (d) That changes to the planned organization and organizational actions, based upon existing circumstances of the emergency, may be made.
In addition, the DEO shall be responsible for proper notification of and initial liaison with the U.S. Nuclear Regulatory Commission and the State ofldaho Emergency Communications Bridge. The DEO shall authorize, upon the recommendation of the
* Radiation Safety and Dose Assessment Coordinator (DAC), emergency workers to incur voluntary doses in excess of normal occupational limits. The DEO shall authorize, upon recommendations from the DAC and the Reactor Safety and Recovery Operations Coordinator (ROC), reentry into areas of the facility that required evacuation following an accident. The DEO shall relate information about the emergency situation to the news media and to the public.
3.3      Radiation Safety and Dose Assessment Coordinator (DAC) 3.3.1  The ISU Radiation Safety officer (RSO) shall be the DAC. In the event that the RSO is unavailable or otherwise incapacitated, the DAC shall be assumed according to the following line of succession:
ISU Radiation Safety Officer Reactor Supervisor Health Physicist Onsite Facility Emergency Plan, Rev. 7 RSC Approval: AugUst 5, 2016 NRC Approval: AugUst 14, 2006                                                                Page 6 of26
3.3.2    The DAC shall be responsible for onsite and offsite dose assessments, including maintenance of records. The DAC shall make recommendations to the DEO for actions that would mitigate the consequences of radiological hazards resulting from the emergency. The DAC shall directly supervise decontamination actions, including the decontamination and/or preparation of contaminated injured personnel using measures to minimize radiation exposures for personnel engaged in corrective and recovery actions.
The responsibilities of the DAC can only be delegated to those in the line of succession.
3 .4      Reactor Safety and Recovery Operations Coordinator (ROC) 3.4.1    The Reactor Supervisor for the ISU AGN-201M Reactor Facility shall be the ROC. In the event that the Chief Reactor Supervisor is unavailable or otherwise incapacitated, the ROC shall be assumed according to the following line of succession:
Reactor Supervisor Senior Reactor Operator Onsite 3.4.2    The ROC shall make recommendations to the DEO for actions that would mitigate the consequences of and resolve emergencies directly involving reactor safety. The ROC shall supervise any such actions. The ROC shall assess reactor core damage, existing or imminent. The ROC shall initiate actions required to assure reactor shutdown, as defined in the ISU AGN-201M Facility Operating License. The ROC shall make recommendations for actions to improve the posture of any security measures that may have been degraded as a result of an accident. The ROC shall supervise onsite recovery actions as directed by the DEO. The responsibilities of the ROC can only be delegated to those in the line of succession.
3.5      Emergency Preparedness Coordinator (EPC)
The Reactor Supervisor of the ISU AGN-201M Reactor Facility shall be the EPC. The EPC shall be responsible for emergency preparedness planning, including the updating of this plan, notification of members of the Emergency Organization and the implementation of procedures.
The EPC shall distribute the Emergency Plan, including approved changes and revisions to appropriate elements of the Emergency Organization. The EPC shall initiate action to obtain, where necessary, written agreement with offsite support agencies to augment and extend the capabilities of the Emergency Organization. The EPC shall ensure that onsite equipment and facilities are available and maintained in the proper state of readiness to support this plan. The EPC shall request review and approval ofrevisions to the Emergency Plan by the ISU AGN Reactor Safety Committee.
3.6      On-Campus Emergency Support Organizations -Appendix B contains the telephone numbers for Emergency Support Organizations, both On-Campus and Off-Campus.
3.6.1    ISU PUBLIC SAFETY DEPARTMENT (ISUPSD) The ISU Public Safety Department is an on-campus organization that maintains a permanent detachment of armed police officers on the ISU campus. It has a full-time director and is responsible for the enforcement of physical security and personnel access regulations. This includes routine access to restricted facilities on campus Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                  Page 7 of26
                                                                    . Communications between ISUPSD Headquarters and patrolling officers is maintained by the use of two-way radios. The ISUPSD maintains a liaison with other law enforcement agencies, including city, county sheriff department and state police, to ensure effective traffic control and crowd control in emergency situations. ISUPSD will coordinate with the DEO to initiate actions that would improve the posture of any security measures that may have been degraded as a result of an accident.
3.6.2  ISU TECHNICAL SAFETY OFFICE (TSO) This ISU organization has the specific function of evaluating and controlling radiological hazards related to ISU activities.
Included in the normal operation of the office is the monitoring of personnel radiation doses and routine radiological emissions at ISU. The ISU Radiation Safety Officer serves as DAC in a nuclear facility Emergency. The TSO provides monitoring and control of radioisotope emission through a staff of trained Radiation Safety Technicians. This includes personnel dose assessment, air sampling, surface contamination sampling and bioassay where designated by the DAC. This organization follows procedures which meet federal guidelines and which have been approved by the U.S. Nuclear Regulatory Commission.
: 3. 7      Off-Campus Emergency Support Agencies 3.7.1 3.7.2 3.7.3 3.7.4 3.7.5 Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                Page 8 of26
4.0      EMERGENCY CLASSIFICATIONS By virtue of the small quantity of fissile material and the negligible fission-product inventory associated with operation of the AGN-201M reactor and the Subcritical Assembly Facility, a release of radioactive material that would require offsite responses is not expected from any credible potential emergency involving the ISU nuclear facilities. Radiological emergencies that may be possible are within the control capabilities of onsite personnel and predetermined responses are specified in the reactor facility operating procedures. Emergencies for which predetermined responses may be necessary by the Emergency Organization outlined in the plan are described in the following classification. The reactor operating staff under the direction of the Reactor Supervisor shall address emergencies of le~ser severity.
4.1      Notification of Unusual Events (NOUE)
Unusual Events shall include man-made events or natural phenomena, existing or imminent, which can be recognized as creating a significant hazard potential that was previously nonexistent and that may be beyond the scope of normal operating procedures, as defined in U.S. NRC NUREG-0849. Notification or mobilization of one or more of the elements of the Emergency Organization may be necessary to increase the state of readiness, to prevent escalation of the emergency or to mitigate . the consequence of an accident should it occur.
5.0      EMERGENCY ACTION LEVELS By virtue of the minimum fission-product inventory, all conditions that might initiate or signal a radiological incident fall into the Notification of Unusual Event (NOUE) Emergency Class. *Within this class, the following action levels are established for the ISU Nuclear Facilities:
(1)    Bomb threat or civil disturbance directed toward the ISU Nuclear Facilities.
(2)    Report or observation of severe natural phenomena, imminent or existing, such as tornadoes or earthquakes that could strike the facility with the potential for degradation of the physical barriers that comprise the Operations Boundary.
(3)    Fire                          lasting more than 10 minutes.
(4)    Radiological Safety Incidents that results in actual or projected radiological effluents at the Site Boundary exceeding 10 MPC (as listed in 10 CFR 20, Appendix B, Table II, Column I) when averaged over 24 hours, or 15 mrem whole body accumulated in 24 hours.
6.0      EMERGENCY PLANNING ZONE Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                Page 9 of26
7.0      EMERGENCY RESPONSE 7 .1    Activation of the Emergency Organization 7 .1.1  Mobilization - The DEO shall be immediately notified of any situation, existing or imminent, equivalent to the Emergency Action Levels specified for Notification of Unusual Events. Notification will normally be initiated by reactor facility operators during working hours and by ISUPSD officers during off-working hours. However, notification may be initiated by any individual recognizing the emergency. The DEO shall determine the extent to which other elements of the Emergency Organization should be activated, commensurate with circumstances of the situation, and shall direct the most efficient method for further notification and/or mobilization.
7:1.2  Emergency Notification Rosters - Emergency Notification Rosters (see Appendix B) that identify the Emergency Organization, the names and phone numbers of personnel in the line of succession for the DEO, ROC, and DAC, and the phone numbers of contacts for police, fire, medical and ambulance support services shall be posted at conspicuous locations in the following areas:
(a) Reactor Laboratory Room, (b) Subcritical Assembly Laboratory Room, (c) Nuclear Engineering Laboratory Entrance Hallway, (d) ISU Public Safety Department, near central communications dispatcher.
7.1.3 7.2      Assessment Actions The DEO shall assess the severity of an emergency situation from first-hand knowledge.
Decisions to escalate or de-escalate emergency response actions shall be made by the DEO based upon personal evaluation of the situation, existing or imminent, and after consideration of recommendations from facility staff, Emergency Organization coordinators, and/or offsite support teams that may be present.
7.3      Protective Actions Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                Page 10 of26
7.3.1  Shutdown of Reactor. For each of the Emergency Action Levels specified in this plan, the reactor shall be placed in the shutdown condition as defined in the Facility Operating License. If the operator determines that an abnormal level of radiation exists within Operations Boundary, then the reactor shall be placed in the shutdown condition as defined in the Facility Operating License.
7.3.2  Evacuation Procedure. For each of the Emergency Action Levels specified in this plan or for abnormal radiation levels within the Operations Boundary, the Nuclear Engineering Laboratory                                                        building shall be evacuated after the reactor is shutdown. The evacuation procedure shall be as follows:
                * (a) The reactor operator has the responsibility of evacuating the building and carrying relevant operation logs and radiation monitors. The operator shall:
(i)
(ii)  Take the reactor console keys and the Operations Log, along with a portable radiation survey meter, if this does not cause a delay; (iii) other instances, notify the DEO by the nearest available telephone of the Emergency; (iv)  The first person to reach the Emergency Ventilation.        . Cut-Out .Switch (located
                                                                          ~. .      ..                "  :
                                                                                  ,,        .    ~
(v)
(b) The reactor operator and other personnel leavin immediate! to the Hold Station
                                                                                              . All personnel shall proceed by the most direct route to that Hold Station and await further instructions.
Accountability of personnel shall be maintained at the Hold Station by the reactor operator.
(c) The DEO shall respond to the Emergency, and individuals shall be allowed to leave the Hold Station or given appropriate attention, based upon the specific circumstances of the Emergency and potential dangers to the safety of the personnel.
Those individuals who, because of their radiological contamination, pose a health risk to others shall be isolated as possible in the circumstances of the accident.
7.3.3  TLD badges and/or self-reading dosimeters shall be worn by all personnel who enter Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                        Page 11 of26
restricted areas. Additional measures such as protective clothing and breathing apparatus may be required as specified by the DAC or DEO. Emergency personnel shall be advised of the extent and locations of any known radiological hazards that may be present in the facility prior to entry into such areas.
Radiation exposures shall normally be limited to the occupational dose limits specified in 10 CFR 20. If warranted by the situation, emergency doses in accordance with 10 CFR 20.1206 may be authorized by the DEO for volunteers but shall be consistent with the Environmental Protection Agency (EPA) Emergency Workers and Lifesaving Activity Protective Action Guides.
7.3.4 Restricted areas shall be posted and access shall be controlled as directed by the DEO consistent with the nature of the emergency.
7.3.5    Radiation dose rates shall be continuously monitored with survey meters and airborne particulate samplers. Those monitors permanently installed within the Operations Boundary shall be used, if accessible, otherwise portable units available to radiation safety personnel shall be used.
7.3.6    Personnel exposures shall be monitored by TLD badge and/or self-reading pocket dosimeters. In the event that unmonitored personnel may have been exposed to radiation, an estimate of exposures shall be made by the DAC based upon surveys and air particulate samples for areas that were occupied, the potential for exposure from the emergency situation that existed during the time such areas were occupied, and standard dose assessment practices.
* 7.4      Corrective Actions The type of actions that could mitigate or correct the problems for each emergency class listed in this plan shall be specified in the Implementing Procedures in section 11.
8.0      EMERGENCY FACILITIES AND EQUIPMENT 8.1      Emergency Support Center (ESC)
                                                                                                  . Emergency control directions will be given from this area. In the event that this location is inaccessible or otherwise considered inade uate for the emergenc at hand, an alternate location should be established                                                                        as directed by the DEO.
Selection of the normal and alternate ESC is based upon the proximity of locations for portable radiation monitoring and sampling equipment, fixed systems for determining specific radionuclide identification and analyses, decontamination equipment, and availability of telephone communications.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                    Page 12 of26
8.2      Assessment Facilities 8 .2.1    Portable survey instruments of sufficient range to determine alpha, beta, gamma, and neutron radiation levels commensurate with potential radiological consequences of credible emergenc situations shall normally be stored, exce t when in use, The Technical Safety Office also maintains portable alpha, 1
beta, gamma and neutron survey instruments.
8.2.2    Fixed area gamma monitors are permanently installed inside the Operations Boundary. Both instruments have visual readout and are equipped with visual and audible alarms that are activated at or below 10 rnrem/hr.
8.2.3    Multichannel Pulse Height Analyzers with photon detectors are located Additional gamma-ra spectroscop systems o Health Physics Program are used by the Technical Safety Office as necessary for radiological assessment.
8.2.4 TLD badges are provided for all radiation workers by the ISU Technical Safety Office.
8.2.5    A seismic displacement sensor is permanently attached to the reactor shield water tank and is fully described in the reactor facility operating license.
8.2.6 8.3      Facilities and Methods for Assisting Injured and Contaminated Personnel 8.3. l  Decontamination Facilities - Washing facilities, soaps and detergents, anti-contamination clothing and waste dis osal bags shall be available in
                                              . There is also a decontamination shower there .
                                                                            . Decontamination of personnel and/or equipment shall be performed under the direction of the DAC.
8.3.2    First-Aid Supplies - First-aid supplies shall be available 8.3.3    Transport of Injured Personnel and Emergency Treatment - The Facility Eme~gency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                  Page 13 of26
                  - r e s c u e ambulance service.shall provide emergency treatment and transportation for injured personnel, including those who may be radioactively contaminated 8.3.4    Methods of Handling Contaminated, Injured Personnel - The nature and severity of an injury will determine if first aid and/or decontamination is possible prior to transporting a patient to the medical facility. Action shall be taken to prevent the spread of contamination into open wounds. Contaminated clothing should be removed by the best practical means and, if possible, contaminated areas of the skin should be rinsed with water prior to transport.
If decontamination is not practical, then the extent to which a patient is contaminated shall be noted on a tag attached to the injured person and, as appropriate, measures shall be taken to prevent the spread of contamination to the ambulance and ambulance personnel. The DAC shall assign a member of the facility staff or the TSO to accompany the victim to the medical facility to ensure that the attending physician is fully advised of the extent and type of contamination.
8.4      Emergency Communications System An Emergency Communications System consisting of two-way radios between the ISUPSD officers and their headquarters is staffed by ISUPSD officers on a continuous basis. That system will be used by the Emergency Organization in the event of an emergency.
9.0      RECOVERY Recovery operations to restore the facility to a safe status shall be determined after an assessment of the existing radiation and contamination levels has been made by the DAC and the ROC. Written procedures shall be prepared by the ROC, as needed, and submitted to the DEO for approval.
Recovery operations shall commence and/or reentry into the affected Operations Area shall be permitted only after plans for such action, written or verbal, have been approved by the DEO and reviewed with the facility staff.
If physical damage to the Operations Boundary has occurred, action shall be initiated to promptly reestablish a security system that is at least equivalent, in effect, to the requirements specified in the Reactor Facility Operating License.
10.0    MAINTAINING EMERGENCY PREPAREDNESS The DEO and the EPC are responsible to ensure the proper execution of the Emergency Plan.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                  Page 14 of26
10.1      Reviews and Approvals 10.1. l The Emergency Plan and Implementing Procedures shall be audited under the cognizance of the Reactor Safety Committee (RSC) at least once every two years, with intervals not to exceed 30 months. The RSC, or a subcommittee thereof, shall evaluate the effectiveness of the plan and note the results of the evaluation in their minutes. The RSC shall also approve any changes that may be made to the Emergency Plan. Changes that would alter the scope of the plan or otherwise result in a reduction of Emergency organization capabilities shall not be made without prior approval of the U.S. Nuclear Regulatory Commission (NRC). Changes that are made without prior approval shall be submitted to the NRC within 30 days of the effective date.
10.1.2 The Emergency Plan and Implementing Procedures shall be reviewed by the EPC at least annually, with intervals not to exceed 15 months, and updated as necessary.
10.1.3 Notification Procedures shall be updated as necessary and a visual inspection made annually, with intervals not to exceed 15 months, to verify that current Notification Rosters are posted in designated locations.
10.2. Training and Drills 10.2.l Operators of the AGN-201M Reactor shall receive training in the Emergency Plan and the Implementing Procedures during their initial license training program and shall review the plan and Implementing Procedures at least annually, thereafter. Initial training and subsequent reviews shall be documented in the facility training records.
10.2.2 The training of University personnel who are responsible to act under this Emergency Plan is the responsibility of the Reactor Administrator and the Reactor Supervisor with the assistance of the Technical Safety Office in the area of radiological control. This training will be provided annually, with intervals not to exceed 15 months, to University personnel who may be called upon to assist in the improbable event of a Nuclear Incident. Off-site support organizations are responsible for providing their own training.
10.2.3 Emergency drills shall be conducted annually, with intervals not to exceed 15 months, to test the on-site integrated capability of the Emergency Plan, or a component thereof, and may include instruction periods to develop and maintain skills in a particular operation.
At least every two years, with intervals not to exceed 30 months, communication links and notification procedures with offsite support agencies shall be tested. Drills will normally be scheduled by the EPC and may be initiated as either announced or unannounced events. Actual situations that involve some or all of the Emergency Plan components may be used in lieu of drills.
10.2.4 The EPC, or an observer designated by the EPC, shall provide a critique of each Emergency Plan drill and should distribute a written report within 60 days after each drill occurrence. The EPC shall be responsible for timely corrective action of identified deficiencies.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                  Page 15 of26
10.3      Equipment Maintenance 10.3.1 Portable health physics instruments, including personnel dosimeters that may be used in an emergency, and fixed radiation monitors shall be calibrated at least semiannually, with the intervals not to exceed 8 months.
10.3.2 Emergency equipment used for fire-fighting, radiation detection and air sampling shall normally be checked for proper operation annually, with intervals not to exceed 15 months. Batteries in portable equipment shall be checked prior to each use and annually unless previous experience dictates a more frequent check is required. A complete stock of replacement batteries shall be available for all battery- owered emergency e uipment.
Replacement batteries shall be kept 10.3.3 Emergency equipment shall be inventoried annually, with intervals not to exceed 15 months.
10.3.4 Communications equipment and alarms shall be tested annually, with intervals not to exceed 15 months.
10.3.5 The criticality alarm -              shall be tested annually, with intervals not to exceed 15 months.
11.0      IMPLEMENTING PROCEDURES The Implementing Procedures for the Emergency Plan shall include:
(a) Notification Procedures; (b) Procedures for the evacuation of personnel from within the Operations Boundary of the facility; and (c) Procedures for corrective actions that could mitigate the consequences of situations matching the Emergency Action Levels specified in this Emergency Plan; all of which are contained in this document (see Appendix C for specific emergency procedures).
Emergency personnel shall be allowed to deviate from the actions described in this Emergency Plan in the event of unusual or unanticipated conditions Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: Augtist 14, 2006                                                                Page 16 of26
APPENDIX A.
IDAHO STATE UNNERSITY CAMPUS AND FACILITY FLOOR PLANS 10 !DMNSTRA1XJH _          _________ G4 II AIBKlHtW.l!ILBl4- - - - - - - - - - -t<
2S1 NJJMhll HOUSE* liiMWJSC>>L-----*..564 S.1'tl co 21 AllTIWSEIMSTtlllMlE-- - -.ll!
Idaho    State UNIVERSITY 74 Al\llXJHIEO<~.-_J(](',,\lWDAlfORTTIOI CJ A::::n.~=Wci~--~
58 OJSCOPNK OI llUSl&#xa3;SSAIMiSTAATDj(ll'l.---114
* llUSIESS ITEOlCl1ITTIL-11111ALiltFDENDR GI CJ
                                                                          '1 CollE REID !)IDET)                      --E4 OI CIUr.IRE*ENll'~C11111111.ISl.llL-G6
                                                                          <a COUBlE CE mHWlG'f If<:!                      El Ill COUlWtWJ.(C(lj _ _ _ _ _ _C3 B::;:.~=._~-~ ~
17 llAl1SAElDHOOSE.. _ _ _ _ _ _,,.
f7 llENTALH'IWEMC-llWllER~-__Jl 32 DEHTALH'IWESOOICES
* TIWMlll!lll-          G4 n DESELE1&#xa3;C111C -DOWLHl!DBl- - -510S.MAIN Cl 13 DESELMEOWICS*AAMORY INfll--.1257S.>ld CJ 8' EOOCAroH IEDl*------------1:<
01 ENGIEIJllNG ' WJ!AilllE !Bl--------*G4 751 ENGINEEIHG
* MCEllC~--CIQ....-lW              c:::J c~~~IOENT~~~~
01 AWEltWJ.1'2) _ _ _ _ _ _ Jll 33 RE.STAlXJH-ISU.__ _ _ _ _ QI 83 GAARISONtW.llil'Rll- - - - -_j)4 15 11 GRAl'EUYtWJ.{GRA-.i-GIO.ll)SStrJP_ _ _      --  _-    -_
_    -"' QI II HA2NllOUS WAS1t                              GI lllf.ATPl.>>n                                  . HI D~ ~~v::I----~ o 8' tlMAH DOO.llPllEHT C1111111 lllCJ--J)I CJ I! HYPO$l'1\L..                                G6 "IWSTltAl.ClWnllCI---------''
71 W<lfll.ITDjllOOnL._. _ _ _ _ _G4 Tl LAWElflllmlEN! !'Wl-- -141>BAl!!OHR> Cl 52 IDS NS11ME CE IWlON (14ST)_ _ __ _J) Cl 17 LECTUECOOEA~q---------C3 II< LEEJIAlAllTHEGEl\Ul- - - - - - -_Jl4 so lJ!AARY .BJ~ 080lE!llJll-----*-.F*
E"* Ll<EAAACCe.!AATOR..-----'SOOAliltllCl<EMDR      c::i IJIEARM:CB.fMT0RJl9ll:llOll.:M-l*~  ... -ID c::J II MIO-FACIJl'ESSEJM:ES,__ _____ Hi MAY2011                                                                  24 llANTEIW<CEIMIDNlSHOPS ____ _Jj) 12 IMEIM*lllHOMUSE\lllCENAJLllSTORYIWSEj.1"
  -by.
Ill NJlSNl -BECIWIJUlll---- -C2 II M.OS!Nl-*POC.ITWDr.IRE1"3Wl - -ll2 Nol<Nodwvo
                                                                            *PEIRllllNlARTSC1111111 -STEl'lfNSISIW<- Oi OI  P!WlllACf . lfONAll>tWJ.~.-__Jl4
        ...... ~                                                        F: ~S:~l'WSGI-~
IOPl&#xa3;SllEh'l'S~*SE!Ml.HOUSE.-
    &#xa9; Clnl'oli'9                                                          'll NU:Slfm
                                                                            '" ClWl\IHGl&#xa3; *lllTCllNSOH llElmAl !lUADl-G4 ti
    ~Disallledl'oli'9                                                      .. 1&#xa3;QEmlff FAGt11Y      llEl--------"'
40 IElltilE>ll-- - - - - - f5
    @GernPrlill                                                            45 IEEl)GllllASl.lj llYMl- - - -----lM
                                                                            !1 IECJWM(AOOl.________ .J<
t  Hoo.oi'lll'oli'9                                                  21SllPl'IHGIAECEMllGI MAIHIENAllClOSlaS.....J!7 liJ Mui'o1i'9                                                        G: =i.oo:ooYIAliWGY~=----~
7SSl'Ol!ISIORTlD'EOICC1111111\SfllEDl.--C2 Cl OlllciOl'oli'9                                                      31 ST. JOltlSCENTERIS1. ~..- - - - - -G4 Cl II SllWIT IEAll1' CEHl!A-- - - - - -66 fRWodPrlill                                                            11 Sl\WITl.llOH I BOOIGTOPE \PSl"l------66 Q2 -~---------Ill II 11WlE I lWl<<XOOY ~111----___E<
    * -Prlill                                                              t1 TRNtSPOFITATl>H SEFM:ES SHCP- - --"'
    @Vlsio<IPrlill                                                      H:=~~;;::~ c:i
    +llJA!aa&l-                                                            <I llJCA1Xll<ALARTS(>llll!J)___-E4 a eu.Sllp                                                            llllllSllET- -..1!
llGAAOIJATE~                      Ajll
* la Emoigoncyl'lm                                                      51 lldH!OSlllW<<lft.. _ _ ---'P----fl
    ,mllospill--                                                            <a-Cllil'lEX!lMJ<)..Dom-_ _&#xa3;5 43 11!81 tWJ._ _ _ _ -llomL._--15 41 /ilDD.Stw.J_____l)onn, __ ~
S! PUJ.l<<lCXJUITS.. _ _ _ ..lpl _ _ _.,
                                                                            !I IElll\WS (AOOI,_ ___ _..._ __ _,.
54 lllXlEafir _______                    _    .f9
                                                                            .. SCll.llEJ!THElGlfTS . _____ ..lpl_ __.JI Cl Non-ISU                                                            II MNEJ! HOllSE (llAlhl._____ Jlom. ___ _j)4
_______                    .._,_~-....-~~-~-~'-r-r'~-~-~~-r'~-~-~~-r'-t-'~~~=:==-~~=~--- ~
Figure Al . Idaho State University Campus .
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                            Page 17 of26
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006  Page 18 of26
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006  Page 19 of26
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006  Page 20 of26
                                                  , I
                                                    ',I
                                                ,,.'!~'
r Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006  Page 21 of26
APPENDIXB.
Idaho State University REACTOR FACILITY EMERGENCY NOTIFICATION: ROSTER.
Effective Date: July ]st, 20l6 In the event of an emergency involving the !SU Reacfor Fapility Complex in the basement of the LEL Bldg, (Building #5), call the following personnel, in the order given, *until someone positively confirms hat they will respond to. the emergency situation, and will meet !SU Public Safety Officers at the facility "f the situatiori cannofbe tes<ilve*d by phone contact:
Ri'acfo1; Siipe;.-Vis.01::              Maxwi;:ll. Daniels                  C:        (253) 905-1907 W:        (208) 282-4237 enior  Reac~<ir  Open1tor:            Ryan Stewart                        C:.      (208) 949-5844 meritt,Js Prof"of Nuelear Ertgr.: .J:ay Kunze                              H:      .(208) 238-9385 W:        (208) 282-4147 C:        (208) 313-7395 sst. Reactor Administrator:          George Imel                          H:        (208) 242-3509 W:        (208) 282-3732 C:        (208) 705-2344 (Note:. All of the above are appr0 vedfor security access to the nuclear facilities in LEL.)
On-Site SUPPORT ORGANIZATIONS
            !SU Technical Safety Office (TSO):                Richard Brey                H:        (208) 233-8184 And Radiation Safety Officer                                        W:        (208) 282-2667 C:.        (208) 220-2735 IS{J Campus Security (Public Safety Dept.)                                              (208) 282-2515 Off-Site SUPPORT ORGANIZATIO.NS
            *Pocatello Police Department            *        .                                      911
            *Poca\ello Fire Department                                                              911 (208) 236-6066
            *Portneuf Medical Center Emergency Room                                                (208) 239-1801
            ' .s. Nuclear Regulatory Commission                                                    (301) 816"5100
            "'ISU has a Meilloranda*ofUqderstanding with these agencies for emergency response support.
pproved:
Mary uu 'JJUJtZik-Gougar                            3bJune2016 Reactor Administrator                                  Date Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                                        Page 22 of26
APPENDIXC.
EMERGENCY PROCEDURES Cl.      Bomb Threat to Nuclear Facilities.
: 1.      Shut down and secure the reactor or Subcritical Assembly.
: 2.      The person receiving the threat should obtain as much information as possible. Ask the following questions:
(a)      Where is the bomb located?
(b)      What type of bomb is it?
(c)      What time will it go off?
(d)      Why are you doing this?
(e)      Name of person making call.
(f)      Where is the person calling from?
(g)      Is the person making call a male or female?
: 2.      Notify:
(a)      Idaho State University Public Safety, 282-2515 (b)                                ,911
: 3.      The Public Safety dispatcher, upon being notified of the threat, will immediately notify the following offices:                  *
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i) 4.
5.
6.
C2.      Extensive Fire or Explosion at the Nuclear Engineering Laboratory.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                              Page 23 of26
APPENDIXC.
EMERGENCY PROCEDURES Cl.      Bomb Threat to Nuclear Facilities.
: 1. Shut down and secure the reactor or Subcritical Assembly.
: 2. The.person receiving the threat should obtain as much information as possible. Ask the following questions:
(a)      Where is the bomb located?
(b)      What type of bomb is it?
(c)      What time will it go off?
(d)      Why are you doing this?
(e)      Name of person making call.
(f)      Where is the person calling from?
(g)      Is the person making call a male or female?
: 2. Notify:
(a)      ~lie                          Safety, 282-2515 (b)      ~.911
: 3.      The Public Safety dispatcher, upon being notified of the threat, will immediately notify the following offices:                    *
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i) 4.
5.
6.
C2.      Extensive Fire or Explosion at the Nuclear Engineering Laboratory.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                              Page 23 of26
_J
: 1.      Shut down and secure the reactor or Subcritical Assembly.
: 2.      Attempt to extinguish the fire using available fire-fighting equipment. If the fire cannot be controlled, initiate building evacuation by actllating the building fire alarm.
: 3.      Notify the -          Fire Department by the quickest available means, i.e., radio, fire alarm, telephone 911.
: 4.      The -          Fire Department will:
(a)
(b)
(c)
(1)
(2)
: 5.      The DAC and ROC will assist by monitoring the area for radioactive contamination.
C3.      Theft or Attempted Theft of Special Nuclear Material from the Nuclear Facilities.
: 1.      Shut down and secure the reactor or Subcritical Assembly.
I
                                                                                                                    *1
: 2.      If an indication of theft or attempted theft of Special Nuclear Material exists immediately notify the ISU Public Safety Department who will, in turn, notify:
(a)
(b)
(c)
(d)
(e)
(t) 3.
C4.      Civil disturbance Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                  Page 24 of26
: 1. Shut down and secure the reactor or Subcritical Assembly.
2.
3.
4.
CS.      Report or Observation of Severe Natural Phenomena (e.g., tornado, flood, earthquake, etc.).
: 1. Shut down and secure the reactor or Subcritical Assembly.
: 2.      Evacuate the area and seek safety for the duration of the event.
3.
4.
C6.      Evacuation Procedure.
: 1. The licensed reactor operator is cognizant of the detailed emergency plan. HE/SHE SHALL BE IN CHARGE OF FACILITY/BUILDING EVACUATION.
: 2. Use the normal room exit and building exits if possible.
: 3. The radiological monitoring instrument on the reactor console and the reactor operations log book shall be brought from the laboratory room by the reactor operator.
4.
airborne radioactive materials, the reactor operator shall order building evacuation.
: 5. The reactor operator shall initiate building evacuation by tripping one of the building fire alarms located at the bottom of the staircase on the south side (or on the way to the staircase on the north side) of the building
: 6. The first person to reach the Emergency Ventilation Cut-out Switch -
will trip all ventilation off-line.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                                  Page 25 of26
: 7.  - The reactor operator shall notify the DEO and ROC immediately.
8.
Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006                                                  Page 26 of26}}

Latest revision as of 13:22, 24 February 2020

Emergency Plan for Nuclear Facilities at Idaho State University: AGN-201M and Subcritical Assembly
ML17144A139
Person / Time
Site: Idaho State University, 07001374
Issue date: 12/19/2016
From: Dunzik-Gougar M
Idaho State University
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
Download: ML17144A139 (29)


Text

Idaho State UNIVERSITY Nuclear Engineering 995 University Blvd. Idaho Falls, ID 83402 December 19, 2016 NRC Public Document Room U.S. Nuclear Energy Commission Washington, DC 20555-0001 One white Flint North Mail Stop: OWEN E13 11555 Rockville Pike Rockville, MD 20852-2738 C: Xiaosong Yin Kevin Ramsey Research and Test Reactors Br. Fuel Mfg. Br.

MS: 0-12 D 03 MS: E2-C40M

SUBJECT:

Emergency Plan for Nuclear Facilities at Idaho State University: AGN-201 M (License R-110, Docket No.

50-284) and Subcritical Assembly (License No. SNM-1373, Docket No. 70-1374) Redacted for Public Release Attached is a redacted version of the Emergency Plan to allow for public release, as requested by Mr. Xiaosong Yin of NRC.

Sincerely, Mary Lou Dunzik-Gouga Reactor Administrator Idaho State University Attachments:

Emergency Plan, Rev. 7 Redacted Phone: (208) 533-8114 *Fax: (208) 526-8255

/SU is an Equal Oppa1tunity Employer

EMERGENCY PLAN FOR THE NUCLEAR FACILITIES AT IDAHO STATE UNIVERSITY:

AGN-201M NUCLEAR REACTOR (LICENSE NO. R-110, DOC~T NO. 50-284)

AND SUBCRITICAL ASSEMBLY (LICENSE NO. SNM-1373, DOCKET NO. 70-1374)

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006

TABLE OF CONTENTS

1.0 INTRODUCTION

................................................................................................... 3 2.0 DEFINITIONS ......................................................... :.............................................. 4 3.0 ORGANIZATION AND RESPONSIBILITIES ....................................................... 5 3.1 Emergency Organization ............................................................................. 5 3.2 Director of Emergency Operations (DEO) ................................................... 5 3.3 Radiation Safety and Dose Assessment Coordinator (DAC) ......................... 6 3.4 Reactor Safety and Recovery Operations Coordinator (ROC) ...................... 7 3.5 Emergency Preparedness Coordinator (EPC) ............................................... 7 3.6 On-Campus Emergency Support Organizations ........................................... 7

3. 7 Off-Campus Emergency Support Organizations ........................................... 8 4.0 EMERGENCY CLASSIFICATIONS ...................................................................... 9 4.1 Notification ofUnusual Events (NOUE) ...................................................... 9 5.0 EMERGENCY ACTION LEVELS .......................................................................... 9 6.0 EMERGENCY PLANNING ZONE ........................................................... :............. 9 7.0 EMERGENCY RESPONSE .................................................................................. 10 7.1 Activation of the Emergency Organization ................................................ 10 7.2 Assessment Actions ................................................................................... 10 7.3 Protective Actions ..................................................................................... 10 7.4 Corrective Actions ..................................................................................... 12 8.0 EMERGENCY FACILITES AND EQUIPMENT .................................................. 12 8.1 Emergency Support Center (ESC) ............................................................. 12 8.2 Assessment Facilities ................................................................ :................ 13 8.3 Facilities and Methods for Assisting Injured and Contaminated Personnel . 13 8.4 Emergency Communications System ......................................................... 14 9.0 RECOVERY ......................................................................................................... 14 10.0 MAINTAINING EMERGENCY PREPAREDNESS ............................................. 14 10.1 Reviews and Approvals ............................................................................. 15 10.2 Training and Drills .................................................................................... 15 10.3 Equipment Maintenance ............................................................................ 16 11.0 IMPLEMENTING PROCEDURES ....................................................................... 16 Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 1 of26

TABLE OF CONTENTS (CONTINUED)

Figure Al. Cam us ............. *.............................................. 17 Figure A2. .. ............................................ 18 Figure A2. .. ............................................ 19 Figure A4. .............................................. 20 Figure A5. .. ............................................ 21 APPENDIXB.

EMERGENCY ORGANIZATION AND PERSONNEL ............................... , .................... 22 EMERGENCY NOTIFICATION ROSTER ....................................................................... 22 APPENDIXC.

EMERGENCY PROCEDURES ......................................................................................... 23 C 1. Nuclear Emergency ...................................................................................... 23 C2. Bomb Threat ................................................................................................ 23 C3. Extensive Fire or Explosion ........................................................ '. ................. 24 C4. Theft or Attempted Theft of Special Nuclear Material.. ................................. 24 C5. Report or Observation of Severe Natural Phenomena .................................... 25 C6. Evacuation Procedure ....................................... :........................................... 25 Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 2 of26

1.0 INTRODUCTION

This Emergency Plan shall be used as a plan of action to follow in the event of an emergency situation at the nuclear facility located at Idaho State University, Pocatello, Idaho.

The nuclear facility consists of an AGN-201 nuclear reactor manufactured by Aerojet General Nucleonics (AGN) in 1956 and a Subcritical Assembly. The AGN reactor and Subcritical Assembly are owned by Idaho State University and operated under U.S. NRC License Nos. R-110 and SNM-1373, respectively. The reactor is li~imum power of 5 W. The fuel for both facilities consists of u r a n i u m - - - - -

  • The AGN-201 reactor system consists of two basic units, the reactor and the control console.

The reactor unit includes the core consisting ofU02 uniformly dispersed in polyethylene, a graphite reflector, and the lead and water shielding. Fuel loaded control and safety rods are installed vertically from the bottom of the reactor unit. These rods pass by the nuclear instrumentation, which measures the power level. Rod movement is achieved by the use of control rod drive mechanisms that provide safe and efficient operation of the reactor. The weight .

of the reactor unit, with the water shield, is approximately 20,000 pounds; the weight of the t t 1 1

  • b t 800 I d Th AGN-201 reactor is located in

' . building at Idaho State University (ISU).

' < ~ * " ~ ' -!~ ~ I *

" . ... - ~

The Subcritical A s s e m b l y -

  • The Subcritical Assembly fuel consists of containing an aluminum-uranium mixture enriched to -

(1) To describe provisions made through advanced planning to cope with an emergency situation not normally expected from routine operations of the nuclear facilities; and (2) To provide assurances that appropriate measures can and will be taken to mitigate the consequences of such an emergency, should it occur, and thereby further assure the protection of the public health and safety, as well as the safety of radiation workers at

~~~ .

This Emergency Plan was prepared to be in compliance with ANSI/ANS-15 .16-1982, "Emergency Planning for Research Reactors," and NUREG-0849, "Standard review Plan for the review and Evaluation of Emergency Plans for Research and Test Reactors." Differences and variation of this document from those that are used for other reactor facilities realistically reflect the characteristics unique to the ISU Nuclear Facility.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 3 of26

2.0 DEFINITIONS 2.1 Emergency - An emergency is a condition that calls for immediate action, beyond the scope of normal operating procedures, to avoid an accident or mitigate the consequences of one.

2.2 Emergency Organization - The Emergency Organization consists of a Director and a team of technical coordinators who possess the detailed knowledge of the Nuclear Facilities and radiation safety to respond appropriately to any Emergency within the EPZ.

2.3 Director of Emergency Operations CDEO) - The DEO is the individual who has the responsibility of coordinating the response of the Emergency Organization to any Emergency within the EPZ.

2.4 Emergency Preparedness Coordinator (EPC) - The EPC is the individual who has the responsibility of coordinating emergency preparedness, including responsibility and authority for emergency preparedness planning, updating emergency plans and procedures, and coordinating plans with other applicable organizations.

2.5 Radiation Safety Dose Assessment Coordinator (PAC) - The DAC is the individual who has the responsibility for onsite and offsite dose assessments and recommended protective actions.

2.6 Reactor Safety Committee__(RfilJ. - The RSC consists of a group of engineers and scientists, knowledgeable in nuclear reactor matters. The RSC periodically reviews and approves all procedures related to the safe operation of the ISU AGN-201 Reactor Facility, including this Emergency Plan Document.

2. 7 Recovery Operations Coordinator CROC) - The ROC is the individual who has the responsibility of making recommendations to mitigate the consequences of and resolve emergencies directly involving reactor or Subcritical Assembly safety.

2~8 2.9 Emergency Planning Zone CEPZ)- *' . " . . ' , , ~ ., -

Emergency Support Center CESC) - The ESC serves as a coordination area for all

- i e s for addressing the emergency.

2.10 Hold Station - During an emergency, reactor personnel will gather at the Hold Station insuring eve one is accounted for and checked for radioactive contamination 2.11 Operations Area -

2.12 Operations Boundary-2.13 Nuclear Facility - Consists of the AGN-201 nuclear reactor and the Sub critical Assembly.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 4 of26

3.0 ORGANIZATION AND RESPONSIBILITIES 3.1 Emergency Organization The Emergency organization consists of a Director and a team of technical coordinators who possess a detailed knowledge of the Reactor Facility. This team is augmented with selected off-campus agencies that provide response actions normally beyond the capabilities of ISU personnel. Figure 1 shows a block diagram illustrating the structure of the Emergency Organization. Appendix B shows the Emergency Organization and its line of succession along with a current listing of personnel. Updating of Appendix B does not constitute a revision to this Emergency Plan.

Director of Emergency Operations (DEO)

Radiation Safety and Dose Reactor Safety and Recovery Assessment Coordinator Operations Coordinator (DAC) (ROC)

ISU Public Safety Emergency Preparedness Department Coordinator (EPC)

ISU Technical Safety Office i - - - - - - - 1 Reactor Operations Personnel Personnel

. . . . I Figure 1. Emergency Organization for ISU Nuclear Facilities.

3.2 Director of Emergency Operations (DEO) 3.2.1 The Reactor Administrator for the ISU AGN-201M Reactor Facility shall be the Director of Emergency Operations. In the event that the Reactor Administrator is unavailable or Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 5 of26

otherwise incapacitated, the DEO shall be assumed according to the following line of succession:

Reactor Administrator Assistant Reactor Administrator Reactor Supervisor Senior Reactor Operator Onsite 3.2.2. The DEO shall be responsible for classifying the emergency and declaring a Notification of an Unusual Event (NOUE). The DEO shall be responsible for directing all elements of the Emergency Organization to effectively bring the emergency under control. This responsibility shall include the following key decisions:

(a) That specific elements of the Emergency Organization should or should not be activated based upon circumstances of the emergency, existing or imminent; (b) That sufficient control exists such that an emergency, once declared, may be terminated; (c) That recovery actions shall commence; and (d) That changes to the planned organization and organizational actions, based upon existing circumstances of the emergency, may be made.

In addition, the DEO shall be responsible for proper notification of and initial liaison with the U.S. Nuclear Regulatory Commission and the State ofldaho Emergency Communications Bridge. The DEO shall authorize, upon the recommendation of the

  • Radiation Safety and Dose Assessment Coordinator (DAC), emergency workers to incur voluntary doses in excess of normal occupational limits. The DEO shall authorize, upon recommendations from the DAC and the Reactor Safety and Recovery Operations Coordinator (ROC), reentry into areas of the facility that required evacuation following an accident. The DEO shall relate information about the emergency situation to the news media and to the public.

3.3 Radiation Safety and Dose Assessment Coordinator (DAC) 3.3.1 The ISU Radiation Safety officer (RSO) shall be the DAC. In the event that the RSO is unavailable or otherwise incapacitated, the DAC shall be assumed according to the following line of succession:

ISU Radiation Safety Officer Reactor Supervisor Health Physicist Onsite Facility Emergency Plan, Rev. 7 RSC Approval: AugUst 5, 2016 NRC Approval: AugUst 14, 2006 Page 6 of26

3.3.2 The DAC shall be responsible for onsite and offsite dose assessments, including maintenance of records. The DAC shall make recommendations to the DEO for actions that would mitigate the consequences of radiological hazards resulting from the emergency. The DAC shall directly supervise decontamination actions, including the decontamination and/or preparation of contaminated injured personnel using measures to minimize radiation exposures for personnel engaged in corrective and recovery actions.

The responsibilities of the DAC can only be delegated to those in the line of succession.

3 .4 Reactor Safety and Recovery Operations Coordinator (ROC) 3.4.1 The Reactor Supervisor for the ISU AGN-201M Reactor Facility shall be the ROC. In the event that the Chief Reactor Supervisor is unavailable or otherwise incapacitated, the ROC shall be assumed according to the following line of succession:

Reactor Supervisor Senior Reactor Operator Onsite 3.4.2 The ROC shall make recommendations to the DEO for actions that would mitigate the consequences of and resolve emergencies directly involving reactor safety. The ROC shall supervise any such actions. The ROC shall assess reactor core damage, existing or imminent. The ROC shall initiate actions required to assure reactor shutdown, as defined in the ISU AGN-201M Facility Operating License. The ROC shall make recommendations for actions to improve the posture of any security measures that may have been degraded as a result of an accident. The ROC shall supervise onsite recovery actions as directed by the DEO. The responsibilities of the ROC can only be delegated to those in the line of succession.

3.5 Emergency Preparedness Coordinator (EPC)

The Reactor Supervisor of the ISU AGN-201M Reactor Facility shall be the EPC. The EPC shall be responsible for emergency preparedness planning, including the updating of this plan, notification of members of the Emergency Organization and the implementation of procedures.

The EPC shall distribute the Emergency Plan, including approved changes and revisions to appropriate elements of the Emergency Organization. The EPC shall initiate action to obtain, where necessary, written agreement with offsite support agencies to augment and extend the capabilities of the Emergency Organization. The EPC shall ensure that onsite equipment and facilities are available and maintained in the proper state of readiness to support this plan. The EPC shall request review and approval ofrevisions to the Emergency Plan by the ISU AGN Reactor Safety Committee.

3.6 On-Campus Emergency Support Organizations -Appendix B contains the telephone numbers for Emergency Support Organizations, both On-Campus and Off-Campus.

3.6.1 ISU PUBLIC SAFETY DEPARTMENT (ISUPSD) The ISU Public Safety Department is an on-campus organization that maintains a permanent detachment of armed police officers on the ISU campus. It has a full-time director and is responsible for the enforcement of physical security and personnel access regulations. This includes routine access to restricted facilities on campus Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 7 of26

. Communications between ISUPSD Headquarters and patrolling officers is maintained by the use of two-way radios. The ISUPSD maintains a liaison with other law enforcement agencies, including city, county sheriff department and state police, to ensure effective traffic control and crowd control in emergency situations. ISUPSD will coordinate with the DEO to initiate actions that would improve the posture of any security measures that may have been degraded as a result of an accident.

3.6.2 ISU TECHNICAL SAFETY OFFICE (TSO) This ISU organization has the specific function of evaluating and controlling radiological hazards related to ISU activities.

Included in the normal operation of the office is the monitoring of personnel radiation doses and routine radiological emissions at ISU. The ISU Radiation Safety Officer serves as DAC in a nuclear facility Emergency. The TSO provides monitoring and control of radioisotope emission through a staff of trained Radiation Safety Technicians. This includes personnel dose assessment, air sampling, surface contamination sampling and bioassay where designated by the DAC. This organization follows procedures which meet federal guidelines and which have been approved by the U.S. Nuclear Regulatory Commission.

3. 7 Off-Campus Emergency Support Agencies 3.7.1 3.7.2 3.7.3 3.7.4 3.7.5 Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 8 of26

4.0 EMERGENCY CLASSIFICATIONS By virtue of the small quantity of fissile material and the negligible fission-product inventory associated with operation of the AGN-201M reactor and the Subcritical Assembly Facility, a release of radioactive material that would require offsite responses is not expected from any credible potential emergency involving the ISU nuclear facilities. Radiological emergencies that may be possible are within the control capabilities of onsite personnel and predetermined responses are specified in the reactor facility operating procedures. Emergencies for which predetermined responses may be necessary by the Emergency Organization outlined in the plan are described in the following classification. The reactor operating staff under the direction of the Reactor Supervisor shall address emergencies of le~ser severity.

4.1 Notification of Unusual Events (NOUE)

Unusual Events shall include man-made events or natural phenomena, existing or imminent, which can be recognized as creating a significant hazard potential that was previously nonexistent and that may be beyond the scope of normal operating procedures, as defined in U.S. NRC NUREG-0849. Notification or mobilization of one or more of the elements of the Emergency Organization may be necessary to increase the state of readiness, to prevent escalation of the emergency or to mitigate . the consequence of an accident should it occur.

5.0 EMERGENCY ACTION LEVELS By virtue of the minimum fission-product inventory, all conditions that might initiate or signal a radiological incident fall into the Notification of Unusual Event (NOUE) Emergency Class. *Within this class, the following action levels are established for the ISU Nuclear Facilities:

(1) Bomb threat or civil disturbance directed toward the ISU Nuclear Facilities.

(2) Report or observation of severe natural phenomena, imminent or existing, such as tornadoes or earthquakes that could strike the facility with the potential for degradation of the physical barriers that comprise the Operations Boundary.

(3) Fire lasting more than 10 minutes.

(4) Radiological Safety Incidents that results in actual or projected radiological effluents at the Site Boundary exceeding 10 MPC (as listed in 10 CFR 20, Appendix B, Table II, Column I) when averaged over 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, or 15 mrem whole body accumulated in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

6.0 EMERGENCY PLANNING ZONE Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 9 of26

7.0 EMERGENCY RESPONSE 7 .1 Activation of the Emergency Organization 7 .1.1 Mobilization - The DEO shall be immediately notified of any situation, existing or imminent, equivalent to the Emergency Action Levels specified for Notification of Unusual Events. Notification will normally be initiated by reactor facility operators during working hours and by ISUPSD officers during off-working hours. However, notification may be initiated by any individual recognizing the emergency. The DEO shall determine the extent to which other elements of the Emergency Organization should be activated, commensurate with circumstances of the situation, and shall direct the most efficient method for further notification and/or mobilization.

7:1.2 Emergency Notification Rosters - Emergency Notification Rosters (see Appendix B) that identify the Emergency Organization, the names and phone numbers of personnel in the line of succession for the DEO, ROC, and DAC, and the phone numbers of contacts for police, fire, medical and ambulance support services shall be posted at conspicuous locations in the following areas:

(a) Reactor Laboratory Room, (b) Subcritical Assembly Laboratory Room, (c) Nuclear Engineering Laboratory Entrance Hallway, (d) ISU Public Safety Department, near central communications dispatcher.

7.1.3 7.2 Assessment Actions The DEO shall assess the severity of an emergency situation from first-hand knowledge.

Decisions to escalate or de-escalate emergency response actions shall be made by the DEO based upon personal evaluation of the situation, existing or imminent, and after consideration of recommendations from facility staff, Emergency Organization coordinators, and/or offsite support teams that may be present.

7.3 Protective Actions Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 10 of26

7.3.1 Shutdown of Reactor. For each of the Emergency Action Levels specified in this plan, the reactor shall be placed in the shutdown condition as defined in the Facility Operating License. If the operator determines that an abnormal level of radiation exists within Operations Boundary, then the reactor shall be placed in the shutdown condition as defined in the Facility Operating License.

7.3.2 Evacuation Procedure. For each of the Emergency Action Levels specified in this plan or for abnormal radiation levels within the Operations Boundary, the Nuclear Engineering Laboratory building shall be evacuated after the reactor is shutdown. The evacuation procedure shall be as follows:

  • (a) The reactor operator has the responsibility of evacuating the building and carrying relevant operation logs and radiation monitors. The operator shall:

(i)

(ii) Take the reactor console keys and the Operations Log, along with a portable radiation survey meter, if this does not cause a delay; (iii) other instances, notify the DEO by the nearest available telephone of the Emergency; (iv) The first person to reach the Emergency Ventilation. . Cut-Out .Switch (located

~. . .. "  :

,, . ~

(v)

(b) The reactor operator and other personnel leavin immediate! to the Hold Station

. All personnel shall proceed by the most direct route to that Hold Station and await further instructions.

Accountability of personnel shall be maintained at the Hold Station by the reactor operator.

(c) The DEO shall respond to the Emergency, and individuals shall be allowed to leave the Hold Station or given appropriate attention, based upon the specific circumstances of the Emergency and potential dangers to the safety of the personnel.

Those individuals who, because of their radiological contamination, pose a health risk to others shall be isolated as possible in the circumstances of the accident.

7.3.3 TLD badges and/or self-reading dosimeters shall be worn by all personnel who enter Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 11 of26

restricted areas. Additional measures such as protective clothing and breathing apparatus may be required as specified by the DAC or DEO. Emergency personnel shall be advised of the extent and locations of any known radiological hazards that may be present in the facility prior to entry into such areas.

Radiation exposures shall normally be limited to the occupational dose limits specified in 10 CFR 20. If warranted by the situation, emergency doses in accordance with 10 CFR 20.1206 may be authorized by the DEO for volunteers but shall be consistent with the Environmental Protection Agency (EPA) Emergency Workers and Lifesaving Activity Protective Action Guides.

7.3.4 Restricted areas shall be posted and access shall be controlled as directed by the DEO consistent with the nature of the emergency.

7.3.5 Radiation dose rates shall be continuously monitored with survey meters and airborne particulate samplers. Those monitors permanently installed within the Operations Boundary shall be used, if accessible, otherwise portable units available to radiation safety personnel shall be used.

7.3.6 Personnel exposures shall be monitored by TLD badge and/or self-reading pocket dosimeters. In the event that unmonitored personnel may have been exposed to radiation, an estimate of exposures shall be made by the DAC based upon surveys and air particulate samples for areas that were occupied, the potential for exposure from the emergency situation that existed during the time such areas were occupied, and standard dose assessment practices.

  • 7.4 Corrective Actions The type of actions that could mitigate or correct the problems for each emergency class listed in this plan shall be specified in the Implementing Procedures in section 11.

8.0 EMERGENCY FACILITIES AND EQUIPMENT 8.1 Emergency Support Center (ESC)

. Emergency control directions will be given from this area. In the event that this location is inaccessible or otherwise considered inade uate for the emergenc at hand, an alternate location should be established as directed by the DEO.

Selection of the normal and alternate ESC is based upon the proximity of locations for portable radiation monitoring and sampling equipment, fixed systems for determining specific radionuclide identification and analyses, decontamination equipment, and availability of telephone communications.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 12 of26

8.2 Assessment Facilities 8 .2.1 Portable survey instruments of sufficient range to determine alpha, beta, gamma, and neutron radiation levels commensurate with potential radiological consequences of credible emergenc situations shall normally be stored, exce t when in use, The Technical Safety Office also maintains portable alpha, 1

beta, gamma and neutron survey instruments.

8.2.2 Fixed area gamma monitors are permanently installed inside the Operations Boundary. Both instruments have visual readout and are equipped with visual and audible alarms that are activated at or below 10 rnrem/hr.

8.2.3 Multichannel Pulse Height Analyzers with photon detectors are located Additional gamma-ra spectroscop systems o Health Physics Program are used by the Technical Safety Office as necessary for radiological assessment.

8.2.4 TLD badges are provided for all radiation workers by the ISU Technical Safety Office.

8.2.5 A seismic displacement sensor is permanently attached to the reactor shield water tank and is fully described in the reactor facility operating license.

8.2.6 8.3 Facilities and Methods for Assisting Injured and Contaminated Personnel 8.3. l Decontamination Facilities - Washing facilities, soaps and detergents, anti-contamination clothing and waste dis osal bags shall be available in

. There is also a decontamination shower there .

. Decontamination of personnel and/or equipment shall be performed under the direction of the DAC.

8.3.2 First-Aid Supplies - First-aid supplies shall be available 8.3.3 Transport of Injured Personnel and Emergency Treatment - The Facility Eme~gency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 13 of26

- r e s c u e ambulance service.shall provide emergency treatment and transportation for injured personnel, including those who may be radioactively contaminated 8.3.4 Methods of Handling Contaminated, Injured Personnel - The nature and severity of an injury will determine if first aid and/or decontamination is possible prior to transporting a patient to the medical facility. Action shall be taken to prevent the spread of contamination into open wounds. Contaminated clothing should be removed by the best practical means and, if possible, contaminated areas of the skin should be rinsed with water prior to transport.

If decontamination is not practical, then the extent to which a patient is contaminated shall be noted on a tag attached to the injured person and, as appropriate, measures shall be taken to prevent the spread of contamination to the ambulance and ambulance personnel. The DAC shall assign a member of the facility staff or the TSO to accompany the victim to the medical facility to ensure that the attending physician is fully advised of the extent and type of contamination.

8.4 Emergency Communications System An Emergency Communications System consisting of two-way radios between the ISUPSD officers and their headquarters is staffed by ISUPSD officers on a continuous basis. That system will be used by the Emergency Organization in the event of an emergency.

9.0 RECOVERY Recovery operations to restore the facility to a safe status shall be determined after an assessment of the existing radiation and contamination levels has been made by the DAC and the ROC. Written procedures shall be prepared by the ROC, as needed, and submitted to the DEO for approval.

Recovery operations shall commence and/or reentry into the affected Operations Area shall be permitted only after plans for such action, written or verbal, have been approved by the DEO and reviewed with the facility staff.

If physical damage to the Operations Boundary has occurred, action shall be initiated to promptly reestablish a security system that is at least equivalent, in effect, to the requirements specified in the Reactor Facility Operating License.

10.0 MAINTAINING EMERGENCY PREPAREDNESS The DEO and the EPC are responsible to ensure the proper execution of the Emergency Plan.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 14 of26

10.1 Reviews and Approvals 10.1. l The Emergency Plan and Implementing Procedures shall be audited under the cognizance of the Reactor Safety Committee (RSC) at least once every two years, with intervals not to exceed 30 months. The RSC, or a subcommittee thereof, shall evaluate the effectiveness of the plan and note the results of the evaluation in their minutes. The RSC shall also approve any changes that may be made to the Emergency Plan. Changes that would alter the scope of the plan or otherwise result in a reduction of Emergency organization capabilities shall not be made without prior approval of the U.S. Nuclear Regulatory Commission (NRC). Changes that are made without prior approval shall be submitted to the NRC within 30 days of the effective date.

10.1.2 The Emergency Plan and Implementing Procedures shall be reviewed by the EPC at least annually, with intervals not to exceed 15 months, and updated as necessary.

10.1.3 Notification Procedures shall be updated as necessary and a visual inspection made annually, with intervals not to exceed 15 months, to verify that current Notification Rosters are posted in designated locations.

10.2. Training and Drills 10.2.l Operators of the AGN-201M Reactor shall receive training in the Emergency Plan and the Implementing Procedures during their initial license training program and shall review the plan and Implementing Procedures at least annually, thereafter. Initial training and subsequent reviews shall be documented in the facility training records.

10.2.2 The training of University personnel who are responsible to act under this Emergency Plan is the responsibility of the Reactor Administrator and the Reactor Supervisor with the assistance of the Technical Safety Office in the area of radiological control. This training will be provided annually, with intervals not to exceed 15 months, to University personnel who may be called upon to assist in the improbable event of a Nuclear Incident. Off-site support organizations are responsible for providing their own training.

10.2.3 Emergency drills shall be conducted annually, with intervals not to exceed 15 months, to test the on-site integrated capability of the Emergency Plan, or a component thereof, and may include instruction periods to develop and maintain skills in a particular operation.

At least every two years, with intervals not to exceed 30 months, communication links and notification procedures with offsite support agencies shall be tested. Drills will normally be scheduled by the EPC and may be initiated as either announced or unannounced events. Actual situations that involve some or all of the Emergency Plan components may be used in lieu of drills.

10.2.4 The EPC, or an observer designated by the EPC, shall provide a critique of each Emergency Plan drill and should distribute a written report within 60 days after each drill occurrence. The EPC shall be responsible for timely corrective action of identified deficiencies.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 15 of26

10.3 Equipment Maintenance 10.3.1 Portable health physics instruments, including personnel dosimeters that may be used in an emergency, and fixed radiation monitors shall be calibrated at least semiannually, with the intervals not to exceed 8 months.

10.3.2 Emergency equipment used for fire-fighting, radiation detection and air sampling shall normally be checked for proper operation annually, with intervals not to exceed 15 months. Batteries in portable equipment shall be checked prior to each use and annually unless previous experience dictates a more frequent check is required. A complete stock of replacement batteries shall be available for all battery- owered emergency e uipment.

Replacement batteries shall be kept 10.3.3 Emergency equipment shall be inventoried annually, with intervals not to exceed 15 months.

10.3.4 Communications equipment and alarms shall be tested annually, with intervals not to exceed 15 months.

10.3.5 The criticality alarm - shall be tested annually, with intervals not to exceed 15 months.

11.0 IMPLEMENTING PROCEDURES The Implementing Procedures for the Emergency Plan shall include:

(a) Notification Procedures; (b) Procedures for the evacuation of personnel from within the Operations Boundary of the facility; and (c) Procedures for corrective actions that could mitigate the consequences of situations matching the Emergency Action Levels specified in this Emergency Plan; all of which are contained in this document (see Appendix C for specific emergency procedures).

Emergency personnel shall be allowed to deviate from the actions described in this Emergency Plan in the event of unusual or unanticipated conditions Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: Augtist 14, 2006 Page 16 of26

APPENDIX A.

IDAHO STATE UNNERSITY CAMPUS AND FACILITY FLOOR PLANS 10 !DMNSTRA1XJH _ _________ G4 II AIBKlHtW.l!ILBl4- - - - - - - - - - -t<

2S1 NJJMhll HOUSE* liiMWJSC>>L-----*..564 S.1'tl co 21 AllTIWSEIMSTtlllMlE-- - -.ll!

Idaho State UNIVERSITY 74 Al\llXJHIEO<~.-_J(](',,\lWDAlfORTTIOI CJ A::::n.~=Wci~--~

58 OJSCOPNK OI llUSl£SSAIMiSTAATDj(ll'l.---114

  • llUSIESS ITEOlCl1ITTIL-11111ALiltFDENDR GI CJ

'1 CollE REID !)IDET) --E4 OI CIUr.IRE*ENll'~C11111111.ISl.llL-G6

<a COUBlE CE mHWlG'f If<:! El Ill COUlWtWJ.(C(lj _ _ _ _ _ _C3 B::;:.~=._~-~ ~

17 llAl1SAElDHOOSE.. _ _ _ _ _ _,,.

f7 llENTALH'IWEMC-llWllER~-__Jl 32 DEHTALH'IWESOOICES

  • TIWMlll!lll- G4 n DESELE1£C111C -DOWLHl!DBl- - -510S.MAIN Cl 13 DESELMEOWICS*AAMORY INfll--.1257S.>ld CJ 8' EOOCAroH IEDl*------------1:<

01 ENGIEIJllNG ' WJ!AilllE !Bl--------*G4 751 ENGINEEIHG

  • MCEllC~--CIQ....-lW c:::J c~~~IOENT~~~~

01 AWEltWJ.1'2) _ _ _ _ _ _ Jll 33 RE.STAlXJH-ISU.__ _ _ _ _ QI 83 GAARISONtW.llil'Rll- - - - -_j)4 15 11 GRAl'EUYtWJ.{GRA-.i-GIO.ll)SStrJP_ _ _ -- _- -_

_ -"' QI II HA2NllOUS WAS1t GI lllf.ATPl.>>n . HI D~ ~~v::I----~ o 8' tlMAH DOO.llPllEHT C1111111 lllCJ--J)I CJ I! HYPO$l'1\L.. G6 "IWSTltAl.ClWnllCI---------

71 W<lfll.ITDjllOOnL._. _ _ _ _ _G4 Tl LAWElflllmlEN! !'Wl-- -141>BAl!!OHR> Cl 52 IDS NS11ME CE IWlON (14ST)_ _ __ _J) Cl 17 LECTUECOOEA~q---------C3 II< LEEJIAlAllTHEGEl\Ul- - - - - - -_Jl4 so lJ!AARY .BJ~ 080lE!llJll-----*-.F*

E"* Ll<EAAACCe.!AATOR..-----'SOOAliltllCl<EMDR c::i IJIEARM:CB.fMT0RJl9ll:llOll.:M-l*~ ... -ID c::J II MIO-FACIJl'ESSEJM:ES,__ _____ Hi MAY2011 24 llANTEIW<CEIMIDNlSHOPS ____ _Jj) 12 IMEIM*lllHOMUSE\lllCENAJLllSTORYIWSEj.1"

-by.

Ill NJlSNl -BECIWIJUlll---- -C2 II M.OS!Nl-*POC.ITWDr.IRE1"3Wl - -ll2 Nol<Nodwvo

  • PEIRllllNlARTSC1111111 -STEl'lfNSISIW<- Oi OI P!WlllACf . lfONAll>tWJ.~.-__Jl4

...... ~ F: ~S:~l'WSGI-~

IOPl£SllEh'l'S~*SE!Ml.HOUSE.-

© Clnl'oli'9 'll NU:Slfm

'" ClWl\IHGl£ *lllTCllNSOH llElmAl !lUADl-G4 ti

~Disallledl'oli'9 .. 1£QEmlff FAGt11Y llEl--------"'

40 IElltilE>ll-- - - - - - f5

@GernPrlill 45 IEEl)GllllASl.lj llYMl- - - -----lM

!1 IECJWM(AOOl.________ .J<

t Hoo.oi'lll'oli'9 21SllPl'IHGIAECEMllGI MAIHIENAllClOSlaS.....J!7 liJ Mui'o1i'9 G: =i.oo:ooYIAliWGY~=----~

7SSl'Ol!ISIORTlD'EOICC1111111\SfllEDl.--C2 Cl OlllciOl'oli'9 31 ST. JOltlSCENTERIS1. ~..- - - - - -G4 Cl II SllWIT IEAll1' CEHl!A-- - - - - -66 fRWodPrlill 11 Sl\WITl.llOH I BOOIGTOPE \PSl"l------66 Q2 -~---------Ill II 11WlE I lWl<<XOOY ~111----___E<

  • -Prlill t1 TRNtSPOFITATl>H SEFM:ES SHCP- - --"'

@Vlsio<IPrlill H:=~~;;::~ c:i

+llJA!aa&l- <I llJCA1Xll<ALARTS(>llll!J)___-E4 a eu.Sllp llllllSllET- -..1!

llGAAOIJATE~ Ajll

  • la Emoigoncyl'lm 51 lldH!OSlllW<<lft.. _ _ ---'P----fl

,mllospill-- <a-Cllil'lEX!lMJ<)..Dom-_ _£5 43 11!81 tWJ._ _ _ _ -llomL._--15 41 /ilDD.Stw.J_____l)onn, __ ~

S! PUJ.l<<lCXJUITS.. _ _ _ ..lpl _ _ _.,

!I IElll\WS (AOOI,_ ___ _..._ __ _,.

54 lllXlEafir _______ _ .f9

.. SCll.llEJ!THElGlfTS . _____ ..lpl_ __.JI Cl Non-ISU II MNEJ! HOllSE (llAlhl._____ Jlom. ___ _j)4

_______ .._,_~-....-~~-~-~'-r-r'~-~-~~-r'~-~-~~-r'-t-'~~~=:==-~~=~--- ~

Figure Al . Idaho State University Campus .

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 17 of26

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 18 of26

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 19 of26

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 20 of26

, I

',I

,,.'!~'

r Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 21 of26

APPENDIXB.

Idaho State University REACTOR FACILITY EMERGENCY NOTIFICATION: ROSTER.

Effective Date: July ]st, 20l6 In the event of an emergency involving the !SU Reacfor Fapility Complex in the basement of the LEL Bldg, (Building #5), call the following personnel, in the order given, *until someone positively confirms hat they will respond to. the emergency situation, and will meet !SU Public Safety Officers at the facility "f the situatiori cannofbe tes<ilve*d by phone contact:

Ri'acfo1; Siipe;.-Vis.01:: Maxwi;:ll. Daniels C: (253) 905-1907 W: (208) 282-4237 enior Reac~<ir Open1tor: Ryan Stewart C:. (208) 949-5844 meritt,Js Prof"of Nuelear Ertgr.: .J:ay Kunze H: .(208) 238-9385 W: (208) 282-4147 C: (208) 313-7395 sst. Reactor Administrator: George Imel H: (208) 242-3509 W: (208) 282-3732 C: (208) 705-2344 (Note:. All of the above are appr0 vedfor security access to the nuclear facilities in LEL.)

On-Site SUPPORT ORGANIZATIONS

!SU Technical Safety Office (TSO): Richard Brey H: (208) 233-8184 And Radiation Safety Officer W: (208) 282-2667 C:. (208) 220-2735 IS{J Campus Security (Public Safety Dept.) (208) 282-2515 Off-Site SUPPORT ORGANIZATIO.NS

  • Pocatello Police Department * . 911
  • Poca\ello Fire Department 911 (208) 236-6066
  • Portneuf Medical Center Emergency Room (208) 239-1801

' .s. Nuclear Regulatory Commission (301) 816"5100

"'ISU has a Meilloranda*ofUqderstanding with these agencies for emergency response support.

pproved:

Mary uu 'JJUJtZik-Gougar 3bJune2016 Reactor Administrator Date Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 22 of26

APPENDIXC.

EMERGENCY PROCEDURES Cl. Bomb Threat to Nuclear Facilities.

1. Shut down and secure the reactor or Subcritical Assembly.
2. The person receiving the threat should obtain as much information as possible. Ask the following questions:

(a) Where is the bomb located?

(b) What type of bomb is it?

(c) What time will it go off?

(d) Why are you doing this?

(e) Name of person making call.

(f) Where is the person calling from?

(g) Is the person making call a male or female?

2. Notify:

(a) Idaho State University Public Safety, 282-2515 (b) ,911

3. The Public Safety dispatcher, upon being notified of the threat, will immediately notify the following offices: *

(a)

(b)

(c)

(d)

(e)

(f)

(g)

(h)

(i) 4.

5.

6.

C2. Extensive Fire or Explosion at the Nuclear Engineering Laboratory.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 23 of26

APPENDIXC.

EMERGENCY PROCEDURES Cl. Bomb Threat to Nuclear Facilities.

1. Shut down and secure the reactor or Subcritical Assembly.
2. The.person receiving the threat should obtain as much information as possible. Ask the following questions:

(a) Where is the bomb located?

(b) What type of bomb is it?

(c) What time will it go off?

(d) Why are you doing this?

(e) Name of person making call.

(f) Where is the person calling from?

(g) Is the person making call a male or female?

2. Notify:

(a) ~lie Safety, 282-2515 (b) ~.911

3. The Public Safety dispatcher, upon being notified of the threat, will immediately notify the following offices: *

(a)

(b)

(c)

(d)

(e)

(f)

(g)

(h)

(i) 4.

5.

6.

C2. Extensive Fire or Explosion at the Nuclear Engineering Laboratory.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 23 of26

_J

1. Shut down and secure the reactor or Subcritical Assembly.
2. Attempt to extinguish the fire using available fire-fighting equipment. If the fire cannot be controlled, initiate building evacuation by actllating the building fire alarm.
3. Notify the - Fire Department by the quickest available means, i.e., radio, fire alarm, telephone 911.
4. The - Fire Department will:

(a)

(b)

(c)

(1)

(2)

5. The DAC and ROC will assist by monitoring the area for radioactive contamination.

C3. Theft or Attempted Theft of Special Nuclear Material from the Nuclear Facilities.

1. Shut down and secure the reactor or Subcritical Assembly.

I

  • 1
2. If an indication of theft or attempted theft of Special Nuclear Material exists immediately notify the ISU Public Safety Department who will, in turn, notify:

(a)

(b)

(c)

(d)

(e)

(t) 3.

C4. Civil disturbance Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 24 of26

1. Shut down and secure the reactor or Subcritical Assembly.

2.

3.

4.

CS. Report or Observation of Severe Natural Phenomena (e.g., tornado, flood, earthquake, etc.).

1. Shut down and secure the reactor or Subcritical Assembly.
2. Evacuate the area and seek safety for the duration of the event.

3.

4.

C6. Evacuation Procedure.

1. The licensed reactor operator is cognizant of the detailed emergency plan. HE/SHE SHALL BE IN CHARGE OF FACILITY/BUILDING EVACUATION.
2. Use the normal room exit and building exits if possible.
3. The radiological monitoring instrument on the reactor console and the reactor operations log book shall be brought from the laboratory room by the reactor operator.

4.

airborne radioactive materials, the reactor operator shall order building evacuation.

5. The reactor operator shall initiate building evacuation by tripping one of the building fire alarms located at the bottom of the staircase on the south side (or on the way to the staircase on the north side) of the building
6. The first person to reach the Emergency Ventilation Cut-out Switch -

will trip all ventilation off-line.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 25 of26

7. - The reactor operator shall notify the DEO and ROC immediately.

8.

Facility Emergency Plan, Rev. 7 RSC Approval: August 5, 2016 NRC Approval: August 14, 2006 Page 26 of26