| title = LER 79-025/03L-0:on 791223,containment Entry Was Made But Personnel Air Lock Not Tested Until 791226,exceeding 48-h Tech Spec Requirement.Caused by Existing Procedural Inadequacy
| title = LER 79-025/03L-0:on 791223,containment Entry Was Made But Personnel Air Lock Not Tested Until 791226,exceeding 48-h Tech Spec Requirement.Caused by Existing Procedural Inadequacy
| author name = PECK C H
| author name = Peck C
| author affiliation = ROCHESTER GAS & ELECTRIC CORP.
| author affiliation = ROCHESTER GAS & ELECTRIC CORP.
| addressee name =  
| addressee name =  
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:NRCFisIsssM366I7.77IU.S.NUCLEARREGULATORY COMMISSION t79-015/03L-0 LICENSEEEVENTREPORT'~O78CON'T,"~O'1,78,'~0'Qi(PLEASEP60-00000-00Qs41111ps~ps2526LICENSETYPE3057CAT58airlockwasnottesteduntil12/26/79~Thisexceededthe48hourreuirementofCONTROLBLOCK:AINTORTYPEALLREQUIREDINFORMATION)
{{#Wiki_filter:NRC FisIsssM 366 I7.77 I CONTROL BLOCK:
INYREG1Q209LICENSEECODE1415LICENSENUMBER~LQB0500024471223798012280Qg6061DOCKETNUMBER'869EVENTDATE7475REPORTDATE80EVENTDESCRIPTION ANDPROBABLECONSEQUENCES QIOAnatpowercontainment entrywasmadeon12/23/79butthecontainment personnel Tech.Spec.4.4.2.4.Theteston12/26/79wasacceptable.
I t      6 Qi 79-015/03L-0 LICENSEE EV ENT REPORT (PLEASE    P AINT OR U. S. NUCLEAR REGULATORY COMMISSION TYPE ALL REQUIRED INFORMATION)
'~OS~O780789gpersonnel airlockisopen.Anewprocedure incheckoffformrequiresthisnotifica-SYSTEMCAUSECAUSECOMP.VALVECODECODESUBCODECOMPONENT CODESUBCODESUBCODE~SAQ1>DQa~ZQ>>RENETRQ4~AQ>>~ZQis78910111213181920SEQUENTIAL OCCURRENCE REPORTREVISIONLERiROEVENTYEARREPORTNO.CODETYPENO.Q17REPORT~79~~Q25~m~03~E~~02122232426272829303132ACTIONFUTUREEFFECTSHUTDOWNATI'ACHMENT NPRDPPRIMECOMP.COMPONENT TAKENACTIONONPLANTMETHODHOURSQ22SUBMITTED FORMSUB.SUPPLIERMANUFACTURER Qlll~~pinggpss~Zp>>0000~Npssgpss~ApssC310p;3334353637404142434447CAUSEDESCRIPTION ANDCORRECTIVE ACTIONSQ27oTheexistingprocedure doesnotreuirenotification oftestandresultsersonnelwhen2tion.3~l4789FACILITYSTATUS%POWEROTHERSTATUSQSOE100NAsQs~Qs78910121344ACTIVITYCONTENTRELEASEDOFRELEASEAMOUNTOFACTIVITY6~ZQ33~2Q34NA789101144PERSONNEL EXPOSURES NUMBERTYPEDESCRIPTION Q3g~000P'~ZP'89111213PERSONNEL INJURIESMETHODOFDISCOVERY DISCOVERY DESCRIPTION Q32Q31Reviewofplantactivities 4546LOCATIONOFRELEASEQ3NA45808080807891112LOSSOFORDAMAGETOFACILITY43TYPEDESCRIPTION
  '~O 7        8    9 NY          RE LICENSEE CODE G1Q20    14      15 0    0        0  0      0 LICENSE NUMBER 0    -    0    0 25 Qs4 26 1      1  1 LICENSE TYPE 1
[ii~]ZQssNA78910PUBLICITY ISSUEDDESCRIPTION Q~2~~NQ44NA89ioNRCUSEONLY8080NAMEOFPREPARERCarlH.Peck686980ssPHQNE.716/546-2700, ext.291-205 0}}
30 ps~ps 57 CAT 58 7
CON'T
  "~O'1,
  '~0' 8
                                      ~LQB 60          61 0    5 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES 0    0  0 DOCKET NUMBER 2
                                                                                    '8 4  4 QIO 7
An at power containment entry was made on 12/23/79 but the containment personnel 69 1    2    2 EVENT DATE 3    7      9 74 8
75 0    1    2 REPORT DATE 2    8    0 80 Qg air lock was not tested until 12/26/79                                    ~    This exceeded the 48 hour re uirement of Tech. Spec.               4.4.2.4.             The  test on 12/26/79 was acceptable.
    '~OS
    ~O7 7        8 9                                                                                                                                                                        80 SYSTEM              CAUSE        CAUSE                                                          COMP.           VALVE CODE                CODE      SUBCODE                  COMPONENT CODE                        SUBCODE          SUBCODE g                          ~SA            Q1>         D    Qa    ~ZQ>>               R    E    N    E    T      R Q4          ~AQ>>             ~Z      Qis 7        8                      9          10          11          12              13                                18          19              20 SEQUENTIAL                            OCCURRENCE             REPORT                        REVISION Q17 LERiRO REPORT ACTION FUTURE EVENT YEAR
                                        ~79 21        22 EFFECT
                                                                ~
23 SHUTDOWN
                                                                              ~Q2 24 REPORT NO.
5 26
                                                                                                        ~m 27
                                                                                                                      ~03 28 ATI'ACHMENT CODE 29 NPRDP TYPE
                                                                                                                                                ~E 30 PRIME COMP.
                                                                                                                                                                ~
31 NO.
                                                                                                                                                                              ~0 32 COMPONENT TAKEN ACTION                  ON PLANT            METHOD                HOURS Q22          SUBMITTED          FORM SUB.         SUPPLIER            MANUFACTURER Qlll ~~     ping        gpss              ~Z p>>             0    0    0      0        ~N      pss        gpss              ~A    pss        C 3      1 0    p; 33          34                35                36            37                    40    41                  42                43              44            47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o          The existing procedure does not re uire                                      notification of test and results ersonnel when personnel air lock is open. A new procedure in check off form requires this notifica-2          tion.
3
    ~l4 7        8    9                                                                                                                                                                    80
                                  ~Qs FACILITY                                                                      METHOD OF STATUS              % POWER                        OTHER STATUS QSO          DISCOVERY                                  DISCOVERY DESCRIPTION Q32 s          E Qs          1    0      0                      NA                              Q31    Review of plant activities 7        8    9              10              12      13                            44      45          46                                                                        80 ACTIVITY CONTENT RELEASED OF RELEASE                          AMOUNTOF ACTIVITY                                                            LOCATION OF RELEASE        Q3 6      ~Z      Q33    ~2Q34                              NA                                                                NA 7        8    9              10          11                                        44              45                                                                            80 PERSONNEL EXPOSURES NUMBER              TYPE        DESCRIPTION Q3g
                  ~00            0    P'~ZP' 8    9                11      12          13                                                                                                                            80 PERSONNEL INJURIES 7        8    9                11      12                                                                                                                                          80 LOSS OF OR DAMAGE TO FACILITY                43 TYPE        DESCRIPTION
[ii~]
7        8    9 Z  Qss 10 NA 80 PUBLICITY
  ~2     ~
ISSUED
                  ~NQ44 DESCRIPTION      Q                    NA NRC USE ONLY 8    9          io                                                                                                                      68    69                          80  ss NAME OF PREPARER                        Carl H. Peck                                                    PHQNE. 716/546-2700, ext. 291-205
 
0}}

Latest revision as of 10:04, 4 February 2020

LER 79-025/03L-0:on 791223,containment Entry Was Made But Personnel Air Lock Not Tested Until 791226,exceeding 48-h Tech Spec Requirement.Caused by Existing Procedural Inadequacy
ML17261A165
Person / Time
Site: Ginna Constellation icon.png
Issue date: 01/22/1980
From: Peck C
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML17249A507 List:
References
LER-79-025-03L, LER-79-25-3L, NUDOCS 8001280246
Download: ML17261A165 (2)


Text

NRC FisIsssM 366 I7.77 I CONTROL BLOCK:

I t 6 Qi 79-015/03L-0 LICENSEE EV ENT REPORT (PLEASE P AINT OR U. S. NUCLEAR REGULATORY COMMISSION TYPE ALL REQUIRED INFORMATION)

'~O 7 8 9 NY RE LICENSEE CODE G1Q20 14 15 0 0 0 0 0 LICENSE NUMBER 0 - 0 0 25 Qs4 26 1 1 1 LICENSE TYPE 1

30 ps~ps 57 CAT 58 7

CON'T

"~O'1,

'~0' 8

~LQB 60 61 0 5 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES 0 0 0 DOCKET NUMBER 2

'8 4 4 QIO 7

An at power containment entry was made on 12/23/79 but the containment personnel 69 1 2 2 EVENT DATE 3 7 9 74 8

75 0 1 2 REPORT DATE 2 8 0 80 Qg air lock was not tested until 12/26/79 ~ This exceeded the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> re uirement of Tech. Spec. 4.4.2.4. The test on 12/26/79 was acceptable.

'~OS

~O7 7 8 9 80 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE g ~SA Q1> D Qa ~ZQ>> R E N E T R Q4 ~AQ>> ~Z Qis 7 8 9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION Q17 LERiRO REPORT ACTION FUTURE EVENT YEAR

~79 21 22 EFFECT

~

23 SHUTDOWN

~Q2 24 REPORT NO.

5 26

~m 27

~03 28 ATI'ACHMENT CODE 29 NPRDP TYPE

~E 30 PRIME COMP.

~

31 NO.

~0 32 COMPONENT TAKEN ACTION ON PLANT METHOD HOURS Q22 SUBMITTED FORM SUB. SUPPLIER MANUFACTURER Qlll ~~ ping gpss ~Z p>> 0 0 0 0 ~N pss gpss ~A pss C 3 1 0 p; 33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o The existing procedure does not re uire notification of test and results ersonnel when personnel air lock is open. A new procedure in check off form requires this notifica-2 tion.

3

~l4 7 8 9 80

~Qs FACILITY METHOD OF STATUS  % POWER OTHER STATUS QSO DISCOVERY DISCOVERY DESCRIPTION Q32 s E Qs 1 0 0 NA Q31 Review of plant activities 7 8 9 10 12 13 44 45 46 80 ACTIVITY CONTENT RELEASED OF RELEASE AMOUNTOF ACTIVITY LOCATION OF RELEASE Q3 6 ~Z Q33 ~2Q34 NA NA 7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION Q3g

~00 0 P'~ZP' 8 9 11 12 13 80 PERSONNEL INJURIES 7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY 43 TYPE DESCRIPTION

[ii~]

7 8 9 Z Qss 10 NA 80 PUBLICITY

~2 ~

ISSUED

~NQ44 DESCRIPTION Q NA NRC USE ONLY 8 9 io 68 69 80 ss NAME OF PREPARER Carl H. Peck PHQNE. 716/546-2700, ext. 291-205