|
|
(One intermediate revision by the same user not shown) |
Line 17: |
Line 17: |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:,_ --.. *.1, ... , .... .* : * ( 1. | | {{#Wiki_filter:* |
| * CONSUMERS POWER COMPANY PALISADES PLANT 1995 STEAM GENERATOR INSERVICE INSPECTION REPORT OF EDDY CURRENT TESTING DATA EVALUATION REVIEWS AND APPROVALS
| | *.1,. . . , .... |
| * Prepared By Thomas D. Rexius Reviews Eddy Current r L_ fa_ I 7 #/ Level Ill Steven R. Wellman Section Head 70' Plant Performance Q!i }_ | | CONSUMERS POWER COMPANY PALISADES NUCLEA~ PLANT 1995 STEAM GENERATOR INSERVICE INSPECTION REPORT OF EDDY CURRENT TESTING DATA EVALUATION REVIEWS AND APPROVALS |
| Approval System Engineering Dept. Manager : ', '* I 9604080240Y960402 | | * Prepared By Thomas D. Rexius |
| '*: PDR AogeK 05000255' G PDR -\ I /I h.<J/9S-Date 1r-/7,/?'S-Date Date'*}} | | /I Date h.<J/9S-Reviews Eddy Current Level Ill r ~--~ L_ fa_ I7#/ |
| | Examine~-~2:~ e...w~ |
| | Steven R. Wellman Plant Performance Section Head Q!i }_ ~ |
| | 70' ~ 1r-/7,/?'S-Judy~ Date Approval System Engineering Dept. Manager /l-~o Date'* |
| | ( I |
| | ~ |
| | 9604080240Y960402 PDR AogeK 05000255' |
| | '*: \ |
| | I 1. |
| | G ~/ PDR- ~*}} |
Latest revision as of 10:29, 3 February 2020
|
---|
Category:PRESERVICE & INSERVICE INSPECTION & TEST REPTS
MONTHYEARML20237E0301998-07-31031 July 1998 ISI Rept 3-3 ML18066A3061998-06-18018 June 1998 SG Tube Inservice Insp. ML18067A6651997-06-23023 June 1997 1996 SG Isi. ML18067A4471997-03-12012 March 1997 ISI Rept 3-1. ML18065A6061995-12-12012 December 1995 CPC Palisades Nuclear Plant 1995 SG Isi. ML18065A3021995-11-16016 November 1995 1995 ISI Rept 2-9. ML18059A9991994-05-19019 May 1994 Special Rept Eddy Current Insp of a & B SGs Jul 1993. ML18059A6611994-02-0303 February 1994 1993 ISI Rept 2-7. ML18058B7171993-03-19019 March 1993 1992 Steam Generator Inservice Insp Rept. ML18058A9721992-07-16016 July 1992 1992 ISI Rept 2-6. ML18054A5441989-02-10010 February 1989 1988 Inservice Insp Rept. ML18054A4241988-11-30030 November 1988 1988 Steam Generator Inservice Insp,Rept of Eddy Current Testing,Data Evaluation & Tube Repair. ML18052B5091988-02-0303 February 1988 1987 Steam Generator Inservice Insp Rept of Eddy Current Testing,Data Evaluation & Tube Repair. ML20203G3491986-04-21021 April 1986 1985 Inservice Insp Rept, Covering 851202-860120 ML18052A2601986-01-31031 January 1986 1985 Steam Generator Inservice Insp Rept of Eddy Current Testing,Data Evaluation & Tube Repair. ML18051B0481984-08-0202 August 1984 Inservice Insp Rept for 831216-840504.All Reportable Indications Re Primary Coolant Pumps Evaluated & Dispositioned to Accept as Is ML20091J7971984-05-25025 May 1984 Final Rept 1983-84 Palisades Steam Generator Eddy Current Inservice Insp on 830830-840430 ML18047A2641982-03-17017 March 1982 Final Inservice Insp Rept 7 for 810913-1222 ML18046A9801981-10-31031 October 1981 Rept of Eddy Current Testing,Data Evaluation & Tube Plugging Oct 1981. ML18045A5621980-08-18018 August 1980 Final Inservice Insp Rept Covering 790908-800528.Includes Data Submitted by Southwest Research Institute 1998-07-31
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML18066A6901999-11-0101 November 1999 Rev 5 to Palisades Nuclear Plant Colr. ML18066A6761999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for Palisades Nuclear Plant ML18066A6271999-09-0202 September 1999 LER 98-011-01:on 981217,inadequate Lube Oil Collection Sys for Primary Coolant Pumps Was Noted.Caused by Design Change Not Containing Appropriate Level of Rigor.Exemption from 10CFR50,App R Was Requested.With 990902 Ltr ML18066A6351999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Palisades Nuclear Plant ML18066A6771999-08-31031 August 1999 Operating Data Rept Page of MOR for Aug 1999 for Palisades Nuclear Plant ML18066A6221999-08-20020 August 1999 LER 99-002-00:on 990722,TS Surveillance Was Not Completed within Specified Frequency.Caused by Failure to Incorporate Revised Frequency Into Surveillance Schedule in Timely Manner.Verified Implementation.With 990820 Ltr ML18066A6061999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Palisades Nuclear Plant.With 990803 Ltr ML18066A5201999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Palisades Nuclear Plant.With 990702 Ltr ML18066A4841999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Palisades Nuclear Plant.With 990603 Ltr ML18066A6371999-04-30030 April 1999 Revised Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant ML18068A5941999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant.With 990503 Ltr ML18066A4161999-04-0101 April 1999 Rev 4 to COLR, for Palisades Nuclear Plant ML18066A4501999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Palisades Nuclear Plant.With 990402 Ltr ML18066A4671999-03-31031 March 1999 Rev 0 to SIR-99-032, Flaw Tolerance & Leakage Evaluation Spent Fuel Pool Heat Exchanger E-53B Nozzle Palisades Nuclear Plant. ML18068A5351999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Palisades Nuclear Plant.With 990302 Ltr ML18066A3931999-01-31031 January 1999 Monthly Operating Rept for Jan 1999 for Palisades Nuclear Plant.With 990202 Ltr ML18066A3781999-01-20020 January 1999 LER 98-013-00:on 981222,safeguards Transfer Tap Changer Failure Caused Inadvertant DG Start.Caused by Failed Motor Contactor.Contactor Was Replaced.With 990120 Ltr ML20206F6131998-12-31031 December 1998 1998 Consumers Energy Co Annual Rept. with ML18066A3651998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Palisades Nuclear Plant.With 990105 Ltr ML18066A3421998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Palisades Nuclear Plant.With 981202 Ltr ML18066A3301998-11-11011 November 1998 Part 21 Rept Re Potential Safety Hazard Associated with Wrist Pin Assemblies for FM-Alco 251 Engines at Palisades Nuclear Power Plant.Caused by Insufficient Friction Fit Between Pin & Sleeve.Supplier of Pin Will No Longer Be Used ML18068A4921998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Palisades Nuclear Plant.With 981103 Ltr ML18068A4851998-10-29029 October 1998 LER 97-011-01:on 971012,starting of Primary Coolant Pump with SG Temps Greater than Cold Leg Temps Occurred.Caused by Inadequate Procedures & Operator Decision.Sop Used for Starting Primary Coolant Pump Enhanced ML18066A3181998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Palisades Nuclear Plant ML18066A2901998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Palisades Nuclear Power Plant.With 980903 Ltr ML18066A3191998-08-31031 August 1998 Revised Monthly Operating Rept Data for Aug 1998 for Palisades Nuclear Plant ML18066A2831998-08-18018 August 1998 LER 98-010-00:on 980721,reactor Manually Tripped.Caused by Failure of Coupling Which Drives Feedwater Pump Main Lube Oil Pump.Main Lube Oil Pump Coupling & Associated Components Replaced & Satisfactorily Tested ML18066A2771998-08-13013 August 1998 Part 21 Rept Re Deficiency in CE Current Screening Methodology for Determining Limiting Fuel Assembly for Detailed PWR thermal-hydraulic Sa.Evaluations Were Performed for Affected Plants to Determine Effect of Deficiency ML20237E0301998-07-31031 July 1998 ISI Rept 3-3 ML18066A2701998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Palisades Nuclear Plant.W/980803 Ltr ML18066A2311998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Palisades Nuclear Plant ML18066A2261998-06-30030 June 1998 LER 98-009-00:on 980531,small Pinhole Leak Found on One of Welds,During Leak Test Following Replacement of Pcs Sample Isolation Valves.Caused by Welder Error.Leaking Welds Repaired ML18066A3061998-06-18018 June 1998 SG Tube Inservice Insp. ML20249C4951998-06-17017 June 1998 Rev 1 to EA-GEJ-98-01, Palisades Cycle 14 Disposition of Events Review ML18066A1781998-06-0909 June 1998 LER 98-008-00:on 980511,noted That Procedure Did Not Fully Satisfy Requirement to Test High Startup Rate Trip Function. Caused by Misunderstanding of Testing Requirements.Revised TS Surveillance Test Procedure & Reviewed Other Procedures ML18066A1711998-06-0101 June 1998 Part 21 Rept Re Impact of RELAP4 Excessive Variability on Palisades Large Break LOCA ECCS Results.Change in PCT Between Cycle 13 & Cycle 14 Does Not Constitute Significant Change Per 10CFR50.46 ML18066A1741998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Palisades Nuclear Plant.W/980601 Ltr ML18066A2321998-05-31031 May 1998 Revised MOR for May 1998 for Palisades Nuclear Plant ML18068A4701998-05-31031 May 1998 Annual Rept of Changes in ECCS Models Per 10CFR50.46. ML18065B2451998-05-13013 May 1998 LER 98-007-00:on 980413,HPIS Sys Was Noted Inoperable During TS Surveillance Test.Caused by Performance of Flawed Procedure.Operators & Engineers Will Be Trained to Improve Operational Decision Making Through Resources & Knowledge ML18066A2331998-04-30030 April 1998 Revised MOR for Apr 1998 for Palisades Nuclear Plant ML18068A3461998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Palisades Nuclear Plant.W/980501 Ltr ML18066A3411998-04-22022 April 1998 Rev 0 to EMF-98-013, Palisades Cycle 14:Disposition & Analysis of SRP Chapter 15 Events. ML18065B2071998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Palisades Nuclear Plant.W/980403 Ltr ML20217C2741998-03-31031 March 1998 Independent Review - Is Consumers Energy Method (W Method) of Determining Palisades Nuclear Plant Best Estimate Fluence by Combining Transport Calculation & Dosimetry Measurements Technically Sound & Does It Meet Intent of Pts ML18066A2341998-03-31031 March 1998 Revised MOR for Mar 1998 for Palisades Nuclear Plant ML18068A3041998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Palisades Nuclear Plant.W/980302 Ltr ML18066A2351998-02-28028 February 1998 Revised MOR for Feb 1998 for Palisades Nuclear Plant ML18065B1641998-02-0505 February 1998 Rev 0 to Regression Analysis for Containment Prestressing Sys at 25th Year Surveillance. ML18067A8211998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Palisades Nuclear Plant.W/980203 Ltr 1999-09-30
[Table view] |
Text
CONSUMERS POWER COMPANY PALISADES NUCLEA~ PLANT 1995 STEAM GENERATOR INSERVICE INSPECTION REPORT OF EDDY CURRENT TESTING DATA EVALUATION REVIEWS AND APPROVALS
- Prepared By Thomas D. Rexius
/I Date h.<J/9S-Reviews Eddy Current Level Ill r ~--~ L_ fa_ I7#/
Examine~-~2:~ e...w~
Steven R. Wellman Plant Performance Section Head Q!i }_ ~
70' ~ 1r-/7,/?'S-Judy~ Date Approval System Engineering Dept. Manager /l-~o Date'*
( I
~
9604080240Y960402 PDR AogeK 05000255'
'*: \
I 1.
G ~/ PDR- ~*