Issue date | Title | Topic | |
---|---|---|---|
ML18066A690 | 1 November 1999 | Rev 5 to Palisades Nuclear Plant Colr. | Shutdown Margin |
ML18066A676 | 30 September 1999 | Monthly Operating Rept for Sept 1999 for Palisades Nuclear Plant | |
ML18066A627 | 2 September 1999 | LER 98-011-01:on 981217,inadequate Lube Oil Collection Sys for Primary Coolant Pumps Was Noted.Caused by Design Change Not Containing Appropriate Level of Rigor.Exemption from 10CFR50,App R Was Requested.With 990902 Ltr | |
ML18066A635 | 31 August 1999 | Monthly Operating Rept for Aug 1999 for Palisades Nuclear Plant | |
ML18066A677 | 31 August 1999 | Operating Data Rept Page of MOR for Aug 1999 for Palisades Nuclear Plant | |
ML18066A622 | 20 August 1999 | LER 99-002-00:on 990722,TS Surveillance Was Not Completed within Specified Frequency.Caused by Failure to Incorporate Revised Frequency Into Surveillance Schedule in Timely Manner.Verified Implementation.With 990820 Ltr | |
ML18066A606 | 31 July 1999 | Monthly Operating Rept for July 1999 for Palisades Nuclear Plant.With 990803 Ltr | |
ML18066A520 | 30 June 1999 | Monthly Operating Rept for June 1999 for Palisades Nuclear Plant.With 990702 Ltr | |
ML18066A484 | 31 May 1999 | Monthly Operating Rept for May 1999 for Palisades Nuclear Plant.With 990603 Ltr | |
ML18066A637 | 30 April 1999 | Revised Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant | |
ML18068A594 | 30 April 1999 | Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant.With 990503 Ltr | |
ML18066A416 | 1 April 1999 | Rev 4 to COLR, for Palisades Nuclear Plant | Shutdown Margin |
ML18066A450 | 31 March 1999 | Monthly Operating Rept for Mar 1999 for Palisades Nuclear Plant.With 990402 Ltr | |
ML18066A467 | 31 March 1999 | Rev 0 to SIR-99-032, Flaw Tolerance & Leakage Evaluation Spent Fuel Pool Heat Exchanger E-53B Nozzle Palisades Nuclear Plant. | Safe Shutdown Earthquake Finite Element Analysis |
ML18068A535 | 28 February 1999 | Monthly Operating Rept for Feb 1999 for Palisades Nuclear Plant.With 990302 Ltr | |
ML18066A393 | 31 January 1999 | Monthly Operating Rept for Jan 1999 for Palisades Nuclear Plant.With 990202 Ltr | |
ML18066A378 | 20 January 1999 | LER 98-013-00:on 981222,safeguards Transfer Tap Changer Failure Caused Inadvertant DG Start.Caused by Failed Motor Contactor.Contactor Was Replaced.With 990120 Ltr | |
ML20206F613 | 31 December 1998 | 1998 Consumers Energy Co Annual Rept. with | |
ML18066A365 | 31 December 1998 | Monthly Operating Rept for Dec 1998 for Palisades Nuclear Plant.With 990105 Ltr | |
ML18066A342 | 30 November 1998 | Monthly Operating Rept for Nov 1998 for Palisades Nuclear Plant.With 981202 Ltr | |
ML18066A330 | 11 November 1998 | Part 21 Rept Re Potential Safety Hazard Associated with Wrist Pin Assemblies for FM-Alco 251 Engines at Palisades Nuclear Power Plant.Caused by Insufficient Friction Fit Between Pin & Sleeve.Supplier of Pin Will No Longer Be Used | |
ML18068A492 | 31 October 1998 | Monthly Operating Rept for Oct 1998 for Palisades Nuclear Plant.With 981103 Ltr | |
ML18068A485 | 29 October 1998 | LER 97-011-01:on 971012,starting of Primary Coolant Pump with SG Temps Greater than Cold Leg Temps Occurred.Caused by Inadequate Procedures & Operator Decision.Sop Used for Starting Primary Coolant Pump Enhanced | |
ML18066A318 | 30 September 1998 | Monthly Operating Rept for Sept 1998 for Palisades Nuclear Plant | |
ML18066A290 | 31 August 1998 | Monthly Operating Rept for Aug 1998 for Palisades Nuclear Power Plant.With 980903 Ltr | |
ML18066A319 | 31 August 1998 | Revised Monthly Operating Rept Data for Aug 1998 for Palisades Nuclear Plant | |
ML18066A283 | 18 August 1998 | LER 98-010-00:on 980721,reactor Manually Tripped.Caused by Failure of Coupling Which Drives Feedwater Pump Main Lube Oil Pump.Main Lube Oil Pump Coupling & Associated Components Replaced & Satisfactorily Tested | |
ML18066A277 | 13 August 1998 | Part 21 Rept Re Deficiency in CE Current Screening Methodology for Determining Limiting Fuel Assembly for Detailed PWR thermal-hydraulic Sa.Evaluations Were Performed for Affected Plants to Determine Effect of Deficiency | |
ML20237E030 | 31 July 1998 | ISI Rept 3-3 | Boric Acid Hydrostatic Nondestructive Examination Liquid penetrant |
ML18066A270 | 31 July 1998 | Monthly Operating Rept for July 1998 for Palisades Nuclear Plant.W/980803 Ltr | |
ML18066A231 | 30 June 1998 | Monthly Operating Rept for June 1998 for Palisades Nuclear Plant | |
ML18066A226 | 30 June 1998 | LER 98-009-00:on 980531,small Pinhole Leak Found on One of Welds,During Leak Test Following Replacement of Pcs Sample Isolation Valves.Caused by Welder Error.Leaking Welds Repaired | Through-Wall Leak |
ML18066A306 | 18 June 1998 | SG Tube Inservice Insp. | |
ML20249C495 | 17 June 1998 | Rev 1 to EA-GEJ-98-01, Palisades Cycle 14 Disposition of Events Review | Shutdown Margin Fire Protection Program Weak link |
ML18066A178 | 9 June 1998 | LER 98-008-00:on 980511,noted That Procedure Did Not Fully Satisfy Requirement to Test High Startup Rate Trip Function. Caused by Misunderstanding of Testing Requirements.Revised TS Surveillance Test Procedure & Reviewed Other Procedures | |
ML18066A171 | 1 June 1998 | Part 21 Rept Re Impact of RELAP4 Excessive Variability on Palisades Large Break LOCA ECCS Results.Change in PCT Between Cycle 13 & Cycle 14 Does Not Constitute Significant Change Per 10CFR50.46 | |
ML18066A174 | 31 May 1998 | Monthly Operating Rept for May 1998 for Palisades Nuclear Plant.W/980601 Ltr | |
ML18066A232 | 31 May 1998 | Revised MOR for May 1998 for Palisades Nuclear Plant | |
ML18068A470 | 31 May 1998 | Annual Rept of Changes in ECCS Models Per 10CFR50.46. | |
ML18065B245 | 13 May 1998 | LER 98-007-00:on 980413,HPIS Sys Was Noted Inoperable During TS Surveillance Test.Caused by Performance of Flawed Procedure.Operators & Engineers Will Be Trained to Improve Operational Decision Making Through Resources & Knowledge | |
ML18066A233 | 30 April 1998 | Revised MOR for Apr 1998 for Palisades Nuclear Plant | |
ML18068A346 | 30 April 1998 | Monthly Operating Rept for Apr 1998 for Palisades Nuclear Plant.W/980501 Ltr | |
ML18066A341 | 22 April 1998 | Rev 0 to EMF-98-013, Palisades Cycle 14:Disposition & Analysis of SRP Chapter 15 Events. | Shutdown Margin Anticipated operational occurrence Rod Drop Event Coast down |
ML18065B207 | 31 March 1998 | Monthly Operating Rept for Mar 1998 for Palisades Nuclear Plant.W/980403 Ltr | |
ML20217C274 | 31 March 1998 | Independent Review - Is Consumers Energy Method (W Method) of Determining Palisades Nuclear Plant Best Estimate Fluence by Combining Transport Calculation & Dosimetry Measurements Technically Sound & Does It Meet Intent of Pts | |
ML18066A234 | 31 March 1998 | Revised MOR for Mar 1998 for Palisades Nuclear Plant | |
ML18068A304 | 28 February 1998 | Monthly Operating Rept for Feb 1998 for Palisades Nuclear Plant.W/980302 Ltr | |
ML18066A235 | 28 February 1998 | Revised MOR for Feb 1998 for Palisades Nuclear Plant | |
ML18065B164 | 5 February 1998 | Rev 0 to Regression Analysis for Containment Prestressing Sys at 25th Year Surveillance. | |
ML18067A821 | 31 January 1998 | Monthly Operating Rept for Jan 1998 for Palisades Nuclear Plant.W/980203 Ltr |