ML13004A336: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(3 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML13004A336
| number = ML13004A336
| issue date = 01/04/2013
| issue date = 01/04/2013
| title = Indian Point Nuclear Generating, Units 2 and 3, Response to Notices of Violation, NRC Inspection Report 05000247-12-009 and 05000286-12-008
| title = Response to Notices of Violation, NRC Inspection Report 05000247-12-009 and 05000286-12-008
| author name = Rogge J F
| author name = Rogge J
| author affiliation = NRC/RGN-I/DRS/EB3
| author affiliation = NRC/RGN-I/DRS/EB3
| addressee name = Ventosa J
| addressee name = Ventosa J
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:UNITED STATESNUCLEAR REGULATORY COiIIiJIISSIONREGION I21OO RENAISSANCE BOULEVARD, SUITE 1OOKING OF PRUSSIA. PENNSYLVANIA 1940S2713January 4, 20L3Mr. John Ventosa, Site Vice PresidentEntergy Nuclear Operations, Inc.lndian Point Energy Center450 Broadway, GSBP.O. Box 249Buchanan, NY 1051 1-0249SUBJECT: INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3RESPONSE TO NOTICES OF VIOLATIONN RC I N S p E CTr O N RE pO RT 05000247 I 20 1 2009 AN D 0500 0286t201 2008Dear Mr. Ventosa:Thank you for your letters of September 17,2012 (ML12268A057) and December 7,2012(Ml-12354A415), in response to the Notices of Violation that were issued in U.S. NuclearRegulatory Commission (NRC) lnspection Report 0500A24712012009 and 0500028612012008,dated August 16,2012 (ML12229A128), regarding the use of unapproved operator manualactions to mitigate safe shutdown equipment malfunctions caused by fire-induced singlespurious actuations in Title 10 of the Code of Federal Regulations (10 CFR) Part 50 AppendixR, Section lll.G.2., Fire Areas. We reviewed your responses and find they meet therequirements of 10 CFR2.201, "Notice of Violation." We will review the implementation of yourcorrective actions during a future inspection to determine that full compliance has beenachieved and will be maintained.Also, in a related matter, we noted that you have included in your December 7,2012letter, astatus of corrective actions for fire-induced multiple spurious operation (MSO) issues.The industry resolution of MSOs was described in NRC Enforcement GuidanceMemorandum 09- 002, Enforcement Discretion for Fire lnduced Circuit Faults, dated May 14,2009 (ML090300446). As discussed in your December 7 ,2012letter, enforcement discretionfor multiple fire induced circuit fault related non-compliances ended on November 2,2012, afterwhich time, such non-compliances were to be dispositioned in accordance with the NRCEnforcement Policy. The NRC has determined that the violations issued to Entergy onAugust 16,2012, pertaining to single spurious actuations, subsumes the MSO non-compliancesat lndian Point Units 2 and 3. Accordingly, we will also review the implementation of your MSOcorrective actions during a future inspection to determine that these are resolved.ln accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will beavailable electronically for public inspection in the NRC Public Document Room or from the  
{{#Wiki_filter:UNITED STATES
J. VentosaPublicly Available Records (PARS) component of the NRC's document system (ADAMS).ADAMS is accessible from the NRC Web Site at http://www.nrc.qov/readinq-rm/adams.html(the Public Electronic Reading Room).Docket Nos: 50-247 ,50-286License Nos: DPR-26. DPR-64cc: Distribution via ListServJohn F. Rogge, ChiefEngineering Branch 3Division of Reactor Safety
                                  NUCLEAR REGULATORY COiIIiJIISSION
J. VentosaPublicly Available Records (PARS) component of the NRC's document system (ADAMS).ADAMS is accessible from the NRC Web Site at http://www.nrc.qov/reading-rm/adams.html(the Public Electronic Reading Room).Sincerely,IRAIJohn F. Rogge, ChiefEngineering Branch 3Division of Reactor SafetyDocket Nos: 50-247.50-286License Nos: DPR-26. DPR-64cc: Distribution via ListServDOCUMENT NAME: G:\DRS\Engineering Branch 3\IPEC OMA Inspection\NOV Response Acknowledge'docxADAMS ACCESSION NUMBER: ML1 3004A336X SUNSlReviewX Non-Sensitiven SensitiveX Publicly Availablen Non-PubliclyAvailableOFFICERI/DRSRI/ORARI/DRSNAMEDOrrMMclaughlinJRoggeDATE12t281121t2t131t2t13OFFICIAL RECORD COPY
                                                  REGION  I
J. VentosaDistribution w/encl: (via E-mail)W. Dean, RAD. Lew, DRAD. Roberts, DRPP. Wilson, DRPC. Miller, DRSJ. Clifford, DRSC. Santos. Rl OEDOM. Gray, DRPB. Bickett, DRPS. McCarver, Acting RlA. Rao, DRPA. Ayegbusi, Acting SRID. Hochmuth, AARidsN rrPMl ndianPoint ResourceRidsNrrDorlLpll -1 ResourceROPreport ResourceD. Orr. DRSJ. Rogge, DRSM. Mclaughlin, ORA
                                  21OO RENAISSANCE BOULEVARD,     SUITE 1OO
                                KING OF PRUSSIA. PENNSYLVANIA 1940S2713
                                              January  4,   20L3
Mr. John Ventosa, Site Vice President
Entergy Nuclear Operations, Inc.
lndian Point Energy Center
450 Broadway, GSB
P.O. Box 249
Buchanan, NY 1051 1-0249
SUBJECT:         INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3
                RESPONSE TO NOTICES OF VIOLATION
                N RC I N S p E CTr O N RE pO RT 05000247 I 20 1 2009 AN D 0500 0286t201 2008
Dear Mr. Ventosa:
Thank you for your letters of September 17,2012 (ML12268A057) and December 7,2012
(Ml-12354A415), in response to the Notices of Violation that were issued in U.S. Nuclear
Regulatory Commission (NRC) lnspection Report 0500A24712012009 and 0500028612012008,
dated August 16,2012 (ML12229A128), regarding the use of unapproved operator manual
actions to mitigate safe shutdown equipment malfunctions caused by fire-induced single
spurious actuations in Title 10 of the Code of Federal Regulations (10 CFR) Part 50 Appendix
R, Section lll.G.2., Fire Areas. We reviewed your responses and find they meet the
requirements of 10 CFR2.201, "Notice of Violation." We will review the implementation of your
corrective actions during a future inspection to determine that full compliance has been
achieved and will be maintained.
Also, in a related matter, we noted that you have included in your December 7,2012letter, a
status of corrective actions for fire-induced multiple spurious operation (MSO) issues.
The industry resolution of MSOs was described in NRC Enforcement Guidance
Memorandum 09- 002, Enforcement Discretion for Fire lnduced Circuit Faults, dated May 14,
2009 (ML090300446). As discussed in your December 7 ,2012letter, enforcement discretion
for multiple fire induced circuit fault related non-compliances ended on November 2,2012, after
which time, such non-compliances were to be dispositioned in accordance with the NRC
Enforcement Policy. The NRC has determined that the violations issued to Entergy on
August 16,2012, pertaining to single spurious actuations, subsumes the MSO non-compliances
at lndian Point Units 2 and 3. Accordingly, we will also review the implementation of your MSO
corrective actions during a future inspection to determine that these are resolved.
ln accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be
available electronically for public inspection in the NRC Public Document Room or from the


J. Ventosa
Publicly Available Records (PARS) component of the NRC's document system (ADAMS).
ADAMS is accessible from the NRC Web Site at http://www.nrc.qov/readinq-rm/adams.html
(the Public Electronic Reading Room).
                                        John F. Rogge, Chief
                                        Engineering Branch 3
                                        Division of Reactor Safety
Docket Nos: 50-247 ,50-286
License Nos: DPR-26. DPR-64
cc: Distribution via ListServ
ML1 3004A336
                                      X    Non-Sensitive                          X Publicly Available
  X  SUNSlReview
                                                                                  n Non-PubliclyAvailable
                                      n    Sensitive
OFFICE        RI/DRS              RI/ORA                  RI/DRS
NAME          DOrr                MMclaughlin            JRogge
DATE          12t28112            1t2t13                  1t2t13
                                         
J. Ventosa
Distribution w/encl: (via E-mail)
W. Dean, RA
D. Lew, DRA
D. Roberts, DRP
P. Wilson, DRP
C. Miller, DRS
J. Clifford, DRS
C. Santos. Rl OEDO
M. Gray, DRP
B. Bickett, DRP
S. McCarver, Acting Rl
A. Rao, DRP
A. Ayegbusi, Acting SRI
D. Hochmuth, AA
RidsN rrPMl ndianPoint Resource
RidsNrrDorlLpll -1 Resource
ROPreport Resource
D. Orr. DRS
J. Rogge, DRS
M. Mclaughlin, ORA
}}
}}

Latest revision as of 16:44, 11 November 2019

Response to Notices of Violation, NRC Inspection Report 05000247-12-009 and 05000286-12-008
ML13004A336
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 01/04/2013
From: Rogge J
Engineering Region 1 Branch 3
To: Ventosa J
Entergy Nuclear Operations
References
IR-12-009, IR-12-008
Download: ML13004A336 (4)


See also: IR 05000247/2012009

Text

UNITED STATES

NUCLEAR REGULATORY COiIIiJIISSION

REGION I

21OO RENAISSANCE BOULEVARD, SUITE 1OO

KING OF PRUSSIA. PENNSYLVANIA 1940S2713

January 4, 20L3

Mr. John Ventosa, Site Vice President

Entergy Nuclear Operations, Inc.

lndian Point Energy Center

450 Broadway, GSB

P.O. Box 249

Buchanan, NY 1051 1-0249

SUBJECT: INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3

RESPONSE TO NOTICES OF VIOLATION

N RC I N S p E CTr O N RE pO RT 05000247 I 20 1 2009 AN D 0500 0286t201 2008

Dear Mr. Ventosa:

Thank you for your letters of September 17,2012 (ML12268A057) and December 7,2012

(Ml-12354A415), in response to the Notices of Violation that were issued in U.S. Nuclear

Regulatory Commission (NRC) lnspection Report 0500A24712012009 and 0500028612012008,

dated August 16,2012 (ML12229A128), regarding the use of unapproved operator manual

actions to mitigate safe shutdown equipment malfunctions caused by fire-induced single

spurious actuations in Title 10 of the Code of Federal Regulations (10 CFR) Part 50 Appendix

R, Section lll.G.2., Fire Areas. We reviewed your responses and find they meet the

requirements of 10 CFR2.201, "Notice of Violation." We will review the implementation of your

corrective actions during a future inspection to determine that full compliance has been

achieved and will be maintained.

Also, in a related matter, we noted that you have included in your December 7,2012letter, a

status of corrective actions for fire-induced multiple spurious operation (MSO) issues.

The industry resolution of MSOs was described in NRC Enforcement Guidance

Memorandum 09- 002, Enforcement Discretion for Fire lnduced Circuit Faults, dated May 14,

2009 (ML090300446). As discussed in your December 7 ,2012letter, enforcement discretion

for multiple fire induced circuit fault related non-compliances ended on November 2,2012, after

which time, such non-compliances were to be dispositioned in accordance with the NRC

Enforcement Policy. The NRC has determined that the violations issued to Entergy on

August 16,2012, pertaining to single spurious actuations, subsumes the MSO non-compliances

at lndian Point Units 2 and 3. Accordingly, we will also review the implementation of your MSO

corrective actions during a future inspection to determine that these are resolved.

ln accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be

available electronically for public inspection in the NRC Public Document Room or from the

J. Ventosa

Publicly Available Records (PARS) component of the NRC's document system (ADAMS).

ADAMS is accessible from the NRC Web Site at http://www.nrc.qov/readinq-rm/adams.html

(the Public Electronic Reading Room).

John F. Rogge, Chief

Engineering Branch 3

Division of Reactor Safety

Docket Nos: 50-247 ,50-286

License Nos: DPR-26. DPR-64

cc: Distribution via ListServ

ML1 3004A336

X Non-Sensitive X Publicly Available

X SUNSlReview

n Non-PubliclyAvailable

n Sensitive

OFFICE RI/DRS RI/ORA RI/DRS

NAME DOrr MMclaughlin JRogge

DATE 12t28112 1t2t13 1t2t13

J. Ventosa

Distribution w/encl: (via E-mail)

W. Dean, RA

D. Lew, DRA

D. Roberts, DRP

P. Wilson, DRP

C. Miller, DRS

J. Clifford, DRS

C. Santos. Rl OEDO

M. Gray, DRP

B. Bickett, DRP

S. McCarver, Acting Rl

A. Rao, DRP

A. Ayegbusi, Acting SRI

D. Hochmuth, AA

RidsN rrPMl ndianPoint Resource

RidsNrrDorlLpll -1 Resource

ROPreport Resource

D. Orr. DRS

J. Rogge, DRS

M. Mclaughlin, ORA