ML13308A389: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(4 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML13308A389
| number = ML13308A389
| issue date = 11/04/2013
| issue date = 11/04/2013
| title = Oconee Nuclear Station Units 1, 2, and 3 - E-mail from R.Guzman to B.Shingleton Request for Additional Information - LAR to Update Pressure Temperature Limit Curves (TACs ME0763/64/65)
| title = E-mail from R.Guzman to B.Shingleton Request for Additional Information - LAR to Update Pressure Temperature Limit Curves (TACs ME0763/64/65)
| author name = Guzman R V
| author name = Guzman R
| author affiliation = NRC/NRR/DORL/LPLII-1
| author affiliation = NRC/NRR/DORL/LPLII-1
| addressee name = Shingleton B
| addressee name = Shingleton B
Line 9: Line 9:
| docket = 05000269, 05000270, 05000287
| docket = 05000269, 05000270, 05000287
| license number = DPR-038, DPR-047, DPR-055
| license number = DPR-038, DPR-047, DPR-055
| contact person = Guzman R V
| contact person = Guzman R
| case reference number = TAC ME0763, TAC ME0764, TAC ME0765
| case reference number = TAC ME0763, TAC ME0764, TAC ME0765
| document type = E-Mail, Request for Additional Information (RAI)
| document type = E-Mail, Request for Additional Information (RAI)
| page count = 1
| page count = 1
| project = TAC:ME0763, TAC:ME0765, TAC:ME0764
| project = TAC:ME0763, TAC:ME0764, TAC:ME0765
| stage = RAI
| stage = RAI
}}
}}


=Text=
=Text=
{{#Wiki_filter:From: Guzman, Richard Sent: Monday, November 04, 2013 8:35 AM To: Shingleton, Boyd (Boyd.Shingleton@duke-energy.com)  
{{#Wiki_filter:From:                   Guzman, Richard Sent:                   Monday, November 04, 2013 8:35 AM To:                     Shingleton, Boyd (Boyd.Shingleton@duke-energy.com)


==Subject:==
==Subject:==
NRC Request for Additional Information - LAR to Update Pressure Temperature Limit Curves for ONS Units 1, 2, and 3, (TACs ME0763/64/65) Boyd, The NRC staff has reviewed the information provided in the subject supplemental RAI response dated September 10, 2013 (Agencywide Document Access and Management System Accession No. ML13259A120), and has determined that additional information is needed to complete its review. Shown below is the NRC staff's request for additional information (RAI) question. This information request was discussed w/your staff on October 22, 2013. As agreed, please provide your formal response by November 29, 2013. Please contact me if you have any questions. Rich Guzman Sr. Project Manager NRR/DORL/LPL1-1 US NRC 301-415-1030  
NRC Request for Additional Information - LAR to Update Pressure Temperature Limit Curves for ONS Units 1, 2, and 3, (TACs ME0763/64/65)
==========================================================================================================================================================================
: Boyd, The NRC staff has reviewed the information provided in the subject supplemental RAI response dated September 10, 2013 (Agencywide Document Access and Management System Accession No. ML13259A120), and has determined that additional information is needed to complete its review. Shown below is the NRC staffs request for additional information (RAI) question. This information request was discussed w/your staff on October 22, 2013. As agreed, please provide your formal response by November 29, 2013. Please contact me if you have any questions.
REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO UPDATE PRESSURE-TEMPERATURE LIMIT CURVES DUKE ENERGY CAROLINAS, LLC OCONEE NUCLEAR STATION UNITS 1, 2, AND 3 DOCKET NOS. 50-269, 50-270, 50-287 (TAC NOS. ME0763, ME0764, AND ME0765)   Section 2.1.2.1.4 of the RAI response dated September 10, 2013, states, "the predicted 54 EFPY fluences at the lower shell forging to Dutchman forging welds are greater than 1017 n/cm2 (E>1 MeV) for all three Oconee RPVs. Therefore, adjusted reference temperature values for the lower head components (transition ring forging, lower head, and their associated welds) were calculated in accordance with Regulatory Guide 1.99, Revision 2 using the lower shell forging to Dutchman forging weld fluences.Please address the upper-shelf energy requirement for the lower head components.
Rich Guzman Sr. Project Manager NRR/DORL/LPL1-1 US NRC 301-415-1030
==========================================================================================================================================================================  
========================================================================
 
========================================================================
}}
==========================
REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO UPDATE PRESSURE-TEMPERATURE LIMIT CURVES DUKE ENERGY CAROLINAS, LLC OCONEE NUCLEAR STATION UNITS 1, 2, AND 3 DOCKET NOS. 50-269, 50-270, 50-287 (TAC NOS. ME0763, ME0764, AND ME0765)
Section 2.1.2.1.4 of the RAI response dated September 10, 2013, states, the predicted 54 EFPY fluences at the lower shell forging to Dutchman forging welds are greater than 1017 n/cm2 (E>1 MeV) for all three Oconee RPVs. Therefore, adjusted reference temperature values for the lower head components (transition ring forging, lower head, and their associated welds) were calculated in accordance with Regulatory Guide 1.99, Revision 2 using the lower shell forging to Dutchman forging weld fluences. Please address the upper-shelf energy requirement for the lower head components.
========================================================================
========================================================================
==========================}}

Latest revision as of 11:51, 4 November 2019

E-mail from R.Guzman to B.Shingleton Request for Additional Information - LAR to Update Pressure Temperature Limit Curves (TACs ME0763/64/65)
ML13308A389
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 11/04/2013
From: Richard Guzman
Plant Licensing Branch II
To: Shingleton B
Duke Energy Carolinas
Guzman R
References
TAC ME0763, TAC ME0764, TAC ME0765
Download: ML13308A389 (1)


Text

{{#Wiki_filter:From: Guzman, Richard Sent: Monday, November 04, 2013 8:35 AM To: Shingleton, Boyd (Boyd.Shingleton@duke-energy.com)

Subject:

NRC Request for Additional Information - LAR to Update Pressure Temperature Limit Curves for ONS Units 1, 2, and 3, (TACs ME0763/64/65)

Boyd, The NRC staff has reviewed the information provided in the subject supplemental RAI response dated September 10, 2013 (Agencywide Document Access and Management System Accession No. ML13259A120), and has determined that additional information is needed to complete its review. Shown below is the NRC staffs request for additional information (RAI) question. This information request was discussed w/your staff on October 22, 2013. As agreed, please provide your formal response by November 29, 2013. Please contact me if you have any questions.

Rich Guzman Sr. Project Manager NRR/DORL/LPL1-1 US NRC 301-415-1030

============================================================
============================================================
==============

REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO UPDATE PRESSURE-TEMPERATURE LIMIT CURVES DUKE ENERGY CAROLINAS, LLC OCONEE NUCLEAR STATION UNITS 1, 2, AND 3 DOCKET NOS. 50-269, 50-270, 50-287 (TAC NOS. ME0763, ME0764, AND ME0765) Section 2.1.2.1.4 of the RAI response dated September 10, 2013, states, the predicted 54 EFPY fluences at the lower shell forging to Dutchman forging welds are greater than 1017 n/cm2 (E>1 MeV) for all three Oconee RPVs. Therefore, adjusted reference temperature values for the lower head components (transition ring forging, lower head, and their associated welds) were calculated in accordance with Regulatory Guide 1.99, Revision 2 using the lower shell forging to Dutchman forging weld fluences. Please address the upper-shelf energy requirement for the lower head components.

============================================================
============================================================

==========================}}