UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555*0001 February 2, 2010 Mr. Charles G. Pardee President and Chief l\\Iuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

QUAD CITIES NUCLEAR POWER STATION, UNIT NOS. 1 AND 2 ALTERNATIVE TO NOZZLE TO VESSEL WELD AND INNER RADIUS EXAMINATIONS (TAC NOS. ME0765 AND ME0766)

Dear Mr. Pardee:

By letter dated March 2, 2009, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML090620369), Exelon Generation Company, LLC (EGC or the licensee), submitted a request for approval to use an alternative to the requirements of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, "Rules for Inservice Inspection (lSI) of Nuclear Power Plant Components," regarding the inspection of certain reactor pressure vessel nozzle-to-vessel welds and nozzle inner radii at Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2. The alternative is in accordance with ASME Code Case N-702, "Alternative Requirements for Boiling-Water Reactor (BWR)

Nozzle Inner Radius and Nozzle-to-Shell Welds."

The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided by the licensee to support the request to authorize the use of the proposed alternative. The NRC staff approved Boiling-Water Reactor Vessels Internal Project (BWRVIP) Report BWRVIP-1 08, "BWR Vessel and Internals Project, Technical Basis for the Reduction of Inspection Requirements for the Boiling-Water Reactor Nozzle-to-Vessel Shell Welds and Nozzle Inner Radii," published by the Electric Power Research Institute, in a safety evaluation (SE) dated December 19, 2007 (ADAMS Accession No. ML073600374). The NRC staff has concluded that the licensee provided adequate information to satisfy the plant-specific requirements stated in the SE, for the use of ASME Code Case 1\\1-702. The NRC staff also concluded that the proposed alternative provides an acceptable level of quality and safety. Although the requested duration is the remainder of the fourth 10-year interval of the QCNPS Inservice Inspection Program which began March 10, 2003, use of ASME Code Case N-702 is authorized until such time as the Code Case is published in a future revision of Regulatory Guide (RG) 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1." At that time, if the licensee intends to continue implementing this Code Case, it must follow all provisions of ASME Code Case N-702 with conditions as specified in RG 1.147 and limitations as specified in 10 CFR 50.55a(b)(4), (b)(5) and (b)(6), if any. The NRC staff SE is enclosed.

C. Pardee

- 2 If you have any questions regarding this authorization, please contact Christopher Gratton at (301) 415-1055.

Sin erely, Stephen Campbell, Chief Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-254 and 50-265

Enclosure:

Safety Evaluation cc w/encl: Distribution via ListServ

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELIEF REQUEST 14R-17 ALTERNATIVE TO REACTOR PRESSURE VESSEL NOZZLE-TO-VESSEL WELDS AND INNER RADIUS EXAMINATIONS QUAD CITIES NUCLEAR POWER STATION, UNITS 1 AND 2 EXELON GENERATION COMPANY, LLC DOCKET NOS. 50-254 AND 50-265

1.0 INTRODUCTION

By letter dated March 2, 2009 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML090620369), Exelon Generation Company, LLC (EGC or the licensee), submitted a request for authorization to use an alternative to American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, "Rules for Inservice Inspection [lSI] of Nuclear Power Plant Components," inspection requirements to inspect certain reactor pressure vessel (RPV) nozzle-to-vessel welds and nozzle inner radii at Quad Cities Nuclear Power Station (QCI\\IPS), Units 1 and 2. The proposed alternative is in accordance with ASME Code Case N-702, "Alternative Requirements for Boiling-Water Reactor (BWR) Nozzle Inner Radius and Nozzle-to-Shell Welds." The technical basis for ASME Code Case N-702 was documented in the Boiling-Water Reactor Vessels Internal Project (BWRVIP)

Report - 108, "BWR Vessel and Internals Project, Technical Basis for the Reduction of Inspection Requirements for the Boiling-Water Reactor Nozzle-to-Vessel Shell Welds and Nozzle Inner Radii," published by the Electric Power Research Institute (EPRI). The BWRVIP-108 report was approved by the Nuclear Regulatory Commission (NRC) staff in a safety evaluation (SE) dated December 19, 2007 (ADAMS Accession 1\\10. ML073600374).

The SE for the BWRVIP-108 report specified plant-specific requirements that must be met by applicants proposing to use this alternative. The March 2, 2009, submittal intended to demonstrate that the relevant QCNPS, Units 1 and 2 RPV nozzle-to-vessel welds and their inner radii meet these plant-specific requirements so that the use of the proposed alternative can be authorized.

2.0 REGULATORY EVALUATION

lSI of ASME Code Class 1,2, and 3 components is performed in accordance with Section XI of the ASME Code and applicable addenda as required by

-2 Title 10 of the Code of Federal Regulations (10 CFR), Section 50.55a(g), except where specific relief has been granted by the Commission pursuant to 10 CFR 50.55a(g)(6)(i). The regulation at 10 CFR 50.55a(a)(3) states that alternatives to the requirements of paragraph (g) may be used, when authorized by the NRC, if: (i) the proposed alternatives would provide an acceptable level of quality and safety or (ii) compliance with the specified requirements would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

Section 50.55a(g)(4) states further that ASME Code Class 1,2, and 3 components (including supports) must meet the requirements, except design and access provisions and preservice examination requirements, set forth in the ASME Code,Section XI to the extent practical within the limitations of design, geometry, and materials of construction of the components. The regulations require that inservice examination of components and system pressure tests conducted during the first 10-year interval and subsequent intervals comply with the requirements in the latest edition and addenda of Section XI of the ASME Code incorporated by reference in 10 CFR 50.55a(b) 12 months prior to the start of the 120-month interval, subject to the limitations and modifications listed therein. The applicable lSI Code of Record for the fourth 1O-year lSI interval for QCNPS, Units 1 and 2 is the 1995 Edition, 1996 Addenda of ASME Code,Section XI.

For all RPV nozzle-to-vessel shell welds and nozzle inner radii, ASME Code,Section XI requires 100 percent inspection during each 1O-year lSI interval. However, ASME Code Case N-702 proposes an alternative which reduces the inspection of RPV nozzle-to-vessel shell welds and nozzle inner radius areas from 100 percent to 25 percent of the nozzles for each nozzle type during each 1O-year interval. As mentioned earlier, the NRC has approved the BWRVIP-108 report, which contains the technical basis supporting ASME Code Case N-702.

The SE for the BWRVIP-1 08 report specified plant-specific requirements to be satisfied by applicants who propose to use ASME Code Case N-702.

3.0 TECHNICAL EVALUATION

The following plant-specific requirements are specified in the SE for the BWRVIP-108 report supporting use of the ASME Code Case N-702:

Each licensee should demonstrate the plant-specific applicability of the BWRVI P-1 08 report to their units in the relief request by showing that all the following general and nozzle-specific criteria are satisfied:

(1) the maximum RPV heatup/cooldown rate is limited to less than 115 degrees Fahrenheit (F) per hour; For recirculation inlet nozzles (2) (pr/t)/CRPV < 1.15 p = RPV normal operating pressure (pounds per square inch gauge (psig)),

r =RPV inner radius (inches (in.)),

-3 t = RPV wall thickness (in.), and CRPV= 19332...;

p = RPV normal operating pressure (psig),

ro = nozzle outer radius (in.),

q = nozzle inner radius (in.), and CNOZZLE= 1637...;

For recirculation outlet nozzles (4) (pr/t)/CRPV < 1.15 p = RPV normal operating pressure (psig),

r = RPV inner radius (in.),

t = RPV wall thickness (in.), and CRPV = 16171...; and p = RPV normal operating pressure (psig),

ro = nozzle outer radius (in.),

q = nozzle inner radius (in.), and CNOZZLE = 1977....

The NRC staff required this plant-specific information to ensure that the probabilistic fracture mechanics (PFM) analysis documented in the BWRVIP-1 08 report applies to the RPV of the applicant's plant.

3.1 ASME Code Requirement for which Alternative is Requested The licensee requested an alternative to the following requirements of ASME Code,Section XI, 1995 Edition, 1996 Addenda:

ASME Code Class 1 nozzle-to-vessel weld and nozzle inner radii examination requirements are delineated in Item Number B3.90, "Nozzle-to-Vessel Welds,"

and B3.100, "Nozzle Inside Radius Section." The required method of examination is volumetric. All nozzles with full penetration welds to the vessel shell (or head) and integrally cast nozzles are examined each interval.

3.2 Component(s) for which Alternative is Requested Code Class:

1 Component Numbers:

N2, N3, N5, N6, N7, and N8 Nozzles (See the licensee's March 2, 2009, submittal for complete list of nozzle identifications)

-4 Examination Category: B-D Item Number:

B3.90 and B3.100 3.3 Licensee's Proposed Alternative to the ASME Code Pursuant to 10 CFR 50.55a(a)(3)(i), relief is requested from performing the required examinations on 100 percent of the nozzle assemblies identified in Tables 5-1, "Unit 1 Summary," and Table 5-2, "Unit 2 Summary," of the licensee's March 2, 2009, submittal. As an alternative for the welds and inner radii identified in Tables 5-1 and 5-2, EGC proposes to examine a minimum of 25 percent of the nozzle-to-vessel welds and inner radius sections, including at least one nozzle from each system and nominal pipe size, in accordance with ASME Code Case N-702.

3.4 Licensee's Bases for Use of the Proposed Alternative Section 5.0, "Plant-Specific Applicability," of the NRC staff's BWRVIP-1 08 SE indicates that each licensee who plans to request relief from the ASME Code,Section XI requirements for RPV nozzle-to-vessel shell welds and nozzle inner radius sections may reference the BWRVIP 108 report as the technical basis for the use of ASME Code Case N-702 as an alternative.

However, each licensee should demonstrate the plant-specific applicability criteria from the BWRVIP-108 report to its units in the relief request by showing that all the general and nozzle specific criteria addressed below are satisfied (i.e., as described in Enclosure 2, "Plant Specific Applicability," of the licensees March 2, 2009, submittal).

Criterion 1: the maximum RPV heatup/cooldown rate is less than 115 degrees F per hour.

QCNPS Technical Specification 3.4.9, "RCS Pressure and Temperature (PIT) Limits," provides a limiting condition for operation and a corresponding surveillance requirement that ensure the reactor coolant system heatup and cooldown rates are less than or equal to 100°F in any 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> period.

Criteria 2 and 3: for recirculation inlet nozzles, (pr/t)/CRPV <1.15; the calculation for the QCNPS N2 Nozzle results in 1.065, which is less than 1.15[.]

[p(r02 +q2)/(r02_q2 )]/C NOZZLE <1.15; the calculation for the QCNPS N2 Nozzle results in 0.972, which is less than 1.15.

Criteria 4 and 5: for recirculation outlet nozzles, (pr/t)/CRPV <1.15; the calculation for the QCNPS N1 Nozzle results in 1.273, which is higher than 1.15.

[p(r02 +q2)/(r02_r? )]/CNOZZLE <1.15; the calculation for the QCNPS N2 Nozzle results in 0.840, which is less than 1.15.

-5 Based upon the above information, the licensee concluded that all QCNPS RPV nozzle-to-vessel shell welds and nozzle inner radii sections, with the exception of the Recirculation Outlet Nozzles, meet the criteria and, therefore, ASME Code Case N-702 is applicable.

3.5

NRC Staff Evaluation

Criteria for Applying the BWRVIP-108 Report The SE for the BWRVIP-1 08 report specified five plant-specific criteria that licensees must meet to demonstrate that the BWRVIP-1 08 report results apply to a unit requesting to use Code Case N-702. The five criteria are related to the driving force of the PFM analyses for the recirculation inlet and outlet nozzles. It was stated in the BWRVIP-1 08 report SE that the nozzle material fracture toughness-related nil-ductility transition reference temperature (RTNOT) values used in the PFM analyses were based on data from the entire fleet of BWR RPVs. Therefore, the BWRVIP-108 report's PFM analyses are bounding with respect to fracture resistance, and only the driving force of the underlying PFM analyses needs to be evaluated. It was also stated in the BWRVIP-1 08 report SE that, except for the RPV heatup/cooldown rate, the plant-specific criteria are for the recirculation inlet and outlet nozzles only, because the probabilities of failure, P(FIE)s, for other nozzles are an order of magnitude lower.

The licensee provided QCNPS's plant-specific data and its evaluation of the five driving force factors, or ratios, against the criteria established in the BWRVIP-1 08 SE. The results of these evaluations bound all nozzles included in this application. The licensee's evaluation indicated that, with exception for the fourth criterion related to the recirculation outlet nozzles, all criteria are satisfied. Based on the results of the evaluation, the licensee decided not to include the recirculation outlet nozzles within the scope of this application. The NRC staff agrees with the licensee's decision to exclude the recirculation outlet nozzles from the scope of this request.

Hence, the NRC staff concluded that the licensee's proposed alternative provides an acceptable level of quality and safety, and applies to all QCNPS RPV nozzles included in this application (see Section 3.2 of this SE). The staff noted that the driving force factor for the recirculation outlet nozzles (1.273), while unacceptable, is only slightly higher than the plant-specific acceptance criterion (1.15). Consequently, the NRC staff concluded that the likelihood of another nozzle exceeding the criterion of 1.15 is extremely low, because the P(FIE)s of the other RPV nozzles are an order of magnitude lower than the recirculation outlet nozzles.

It should also be noted that RPV feedwater nozzles and control rod drive return line nozzles are outside the scope of ASME Code Case N-702 and are, accordingly, outside the scope of this application.

ASME Code Case N-702 permits a VT-1 (visual examination) of the nozzle inner radius without performing a sensitivity demonstration of detecting a 1-mil width wire or crack. This is not consistent with the NRC position established in Regulatory Guide (RG) 1.147, "lnservice Inspection Code Case Acceptability, ASME Section XI, Division 1," regarding ASME Code Case N-648-1, "Alternative Requirements for Inner Radius Examinations of Class 1 Reactor Vessel Nozzles." However, since the licensee stated in its application that it has no plans of using Code Case N-648-1 and volumetric examinations of all nozzle inner radii will be performed, the inconsistency between ASME Code Case N-702 and the NRC position regarding VT-1 examinations is not an issue for this application.

-6

4.0 CONCLUSION

The NRC staff has reviewed the application regarding the licensee's evaluation of the five plant-specific criteria specified in the NRC staff's SE for the BWRVIP-108 report, which provides the technical bases for use of ASME Code Case N-702 to examine RPV nozzle-to-vessel welds and nozzle inner radii at QCI\\IPS, Units 1 and 2. Based on the evaluation in Section 3.5 of this SE, the NRC staff concluded that the licensee's proposed alternative, pursuant to 10 CFR 50.55a(a)(3)(i). which applies to all QCNPS RPV nozzles included in the application (see Section 3.2 of this SE), provides an acceptable level of quality and safety, and is therefore, authorized. It should be noted that the licensee's request did not include, and this SE does not approve, the application of ASME Code Case N-702 to the QCNPS, Units 1 and 2 RPV recirculation outlet nozzles, RPV feedwater nozzles, and control rod drive return nozzles.

Although the requested duration of the authorization is the remainder of the fourth 10-year interval of the QCNPS lSI Program, use of ASME Code Case N-702 for the requested QCI\\IPS RPV nozzles is authorized until such time as the Code Case is published in a revision to RG 1.147. At that time, if the licensee intends to continue to implement the Code Case, the licensee must follow all provisions in ASME Code Case N-702 with conditions as specified in RG 1.147 and limitations as specified in 10 CFR 50.55a(b)(4), (b)(5) and (b)(6), if any.

All other requirements of the ASME Code, Sections III and XI, for which relief has not been specifically requested and approved remain applicable, including third party review by the Authorized Nuclear Inservice Inspector.

Principal Contributor: S. Sheng, NRR Date:

February 2, 2010

C. Pardee

- 2 If you have any questions regarding this authorization, please contact Christopher Gratton at (301) 415-1055.

Sincerely, IRA!

Stephen Campbell, Chief Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-254 and 50-265

Enclosure:

Safety Evaluation cc w/encl: Distribution via ListServ DISTRIBUTION:

PUBLIC LPL3-2 RlF RidsOgcRp Resource RidsNrrLATHarris Resource RidsNrrDorlDprl Resource RidsNrrDorlLpl3-2 Resource SBagley, EDO, Rill RidsNrrDciCptb Resource RidsNrrPMQuadCities Resource RidsRgn3MailCenter Resource RidsAcrsAcnw MailCTR Resource

  • B)y memo d t d ADAMS Accesslon No. ML092860259 NRR 028 ae OFFICE LPL3-2/PM LPL3-2/LA DCI/CVIB/BC NAME CGratton THarris MMitchel1 DATE 02/02/10 02/02/10 7/22/2009*

LPL3-2/BC SCampbel1 02/02/10 OFFICIAL RECORD COPY