MONTHYEARML23284A3322023-10-11011 October 2023 Request for Additional Information Alternative Request (RA-22-0174) (L-2022-LLR-0060) ML23178A0682023-07-0303 July 2023 Audit Plan Proposed Alternative to Use ASME Code Case N-752, Risk-Informed Categorization and Treatment for Repair/Replacement Activities in Class 2 & 3 Systems Section XI, Division 1 ML23156A2452023-06-0505 June 2023 Audit Summary and RAI-RCI - Revised Enclosure ML23151A3482023-05-30030 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23142A2732023-05-22022 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Steam Generator Welds in Accordance with 10 CFR 50.55a(z)(1) ML23095A0052023-04-0404 April 2023 002 Radiation Safety Baseline Inspection Information Request ML23086C0362023-03-27027 March 2023 Request for Additional Information Steam Generator Tube Inspection Report (03R31) ML23039A1632023-02-0808 February 2023 Requalification Program Inspection ML23038A1832023-02-0707 February 2023 Request for Additional Information Alternative Request (RA-22-0174) to Use ASME Code Case N-752 ML23037A0772023-02-0606 February 2023 402 Cyber Notification and RFI Letter Final ML22251A2902022-09-0808 September 2022 Request for Additional Information Additional Mode Change Limitations Applicable to the Adoption of Technical Specifications Tasks Force Traveler (TSTF) No. 359, Revision 9 ML22234A0052022-08-30030 August 2022 SLRA - Feedback for RAI B2.1.7-4a to Duke - August 16, 2022 ML22157A0042022-06-0606 June 2022 10 CFR 50.59 Inspection Initial Information Request ML22157A0012022-06-0101 June 2022 Email from NRC (Angela Wu) to Duke (Paul Guill) - Oconee SLRA - Additional NRC Comments on RAI 4.6.1-1a ML22154A2122022-06-0101 June 2022 SLRA - 2nd Round RAI B2.1.7-4b ML22124A1632022-05-0303 May 2022 (Public) Oconee SLRA - 2nd Round RAI B2.1.7-4a ML22124A1612022-05-0303 May 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round RAI B2.1.7-4a ML22122A0182022-04-28028 April 2022 Attachment: Oconee SLRA - 2nd Round RAI B2.1.9-2a ML22122A0192022-04-28028 April 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round RAI B2.1.9-2a ML22122A1312022-04-27027 April 2022 (Public) Oconee SLRA - 2nd Round RAIs - Trp 76 (Irradiation Structural) - FE 3.5.2.2.2.6 Redacted ML22115A1412022-04-25025 April 2022 NRR E-mail Capture - Duke Common EOF Relocation - Request for Addition Information ML22113A0092022-04-20020 April 2022 Attachment: Oconee SLRA - Final RAI 3.1.2-1 ML22112A0072022-04-20020 April 2022 Email from Marieliz Johnson (NRC) to Steve Snider (Duke) - Oconee SLRA - Request for Confirmation of Information 3.5.2.2.2.6-L ML22081A0062022-03-21021 March 2022 Attachment: Oconee SLRA - 2nd Round RAI B4.1-3 ML22081A0052022-03-21021 March 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round RAI B4.1-3 ML22080A0772022-03-16016 March 2022 SLRA - RAI Set 4 (2nd Round Rais) ML22069A0012022-03-0808 March 2022 Attachment: Oconee SLRA - Final Requests for Confirmation of Information - Set 4 ML22063A4502022-03-0404 March 2022 Request for Additional Information Application to Revise TS 3.7.7, Low Pressure Service Water (LPSW) System, to Extend the Completion Time for One Required Inoperable LPSW Pump RA-22-0036, Responses to NRC Request for Additional Information Set 22022-02-14014 February 2022 Responses to NRC Request for Additional Information Set 2 ML22019A1042022-01-18018 January 2022 Attachment: Oconee SLRA - Final Requests for Additional Information - Set 3 ML22019A2442022-01-18018 January 2022 Notification of an NRC Fire Protection Team Inspection (FPTI) (NRC Inspection Report 05000269/2022010, 05000270/2022010, 05000287/2022010) and Request for Information (RFI) ML22019A1032022-01-18018 January 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - Requests for Additional Information - Set 3 ML22012A0422022-01-11011 January 2022 SLRA - Final Requests for Additional Information - Set 2 ML22010A1132022-01-0505 January 2022 SLRA - RCIs - Set 3 ML21333A0392021-11-29029 November 2021 RP Inspection Document Request ML21330A0192021-11-23023 November 2021 Attachment: Oconee SLRA - Final Requests for Confirmation of Information - Set 2 ML21327A2782021-11-23023 November 2021 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - Final RAIs (Set 1 and 2nd Round RAI B2.1.27-1a) ML21327A2792021-11-23023 November 2021 SLRA - Final Requests for Additional Information - Set 1 ML21327A2802021-11-23023 November 2021 SLRA - Final 2nd Round RAI - RAI B2.1.27-1a ML21313A2342021-11-0404 November 2021 Attachment: Oconee SLRA - Final Requests for Confirmation of Information - Set 1 ML21274A0682021-10-0101 October 2021 Request for Additional Information Alternative Request (RA-20-0334) Regarding Use of an Alternative to the ASME Code Case N-853 Acceptance Criteria ML21273A0492021-09-30030 September 2021 Request for Additional Information Alternative Request (ON-RPI-OMN-28) to Use Code Case OMN-28 ML21271A5892021-09-28028 September 2021 SLRA - RAI B2.1.27-1 (Draft) ML21271A5902021-09-28028 September 2021 SLRA - RAI B2.1.27-1 (Final) ML21271A5882021-09-22022 September 2021 SLRA - Request for Additional Information B2.1.27-1 - Email from Angela Wu (NRC) to Steve Snider (Duke) ML21217A1912021-08-0505 August 2021 Request for Additional Information Alternative Request (RA-20-0334) Regarding Use of an Alternative to the ASME Code Case N-853 Acceptance Criteria ML21190A0172021-07-0808 July 2021 NRR E-mail Capture - Oconee Nuclear Station, Units 1, 2, and 3 - Request for Additional Information Alternative for ISI RPV Weld Examination from 10 to 20 Years (EPID-L-2021-LLR-0004) ML21075A0032021-03-12012 March 2021 Emergency Preparedness Exercise Inspection Request for Information for - Brunswick, Catawba, North Anna, Oconee, Vogtle 1 & 2 ML21049A2632021-02-0404 February 2021 NRR E-mail Capture - Request for Additional Information - Duke Energy Fleet License Amendment Request to Revise Emergency Plan ML20323A4072020-11-18018 November 2020 NRR E-mail Capture - Request for Additional Information - Brunswick License Exemption Request from 10CFR73 Annual Force on Force Exercise Requirements (EPIC L-2020-LLE-0180) 2023-07-03
[Table view] |
Text
Oconee SLRA - RAI B2.1.27-1 Regulatory Basis 10 CFR 54.21(a)(3) requires an applicant to demonstrate that the effects of aging for structures and components will be adequately managed so that the intended function(s) will be maintained consistent with the current licensing basis for the period of extended operation. One of the findings that the staff must make to issue a renewed license (10 CFR 54.29(a)) is that actions have been identified and have been or will be taken with respect to managing the effects of aging during the period of extended operation on the functionality of structures and components that have been identified to require review under 10 CFR 54.21, such that there is reasonable assurance that the activities authorized by the renewed license will continue to be conducted in accordance with the current licensing basis. In order to complete its review and enable making a finding under 10 CFR 54.29(a), the staff requires additional information in regard to the matters described below.
RAI B2.1.27-1 [Breakout Topic No. 3: Alternative programs to manage loss of coating integrity]
Background:
SLRA Section B2.1.27, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks, states [t]he Oconee Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks AMP is a new program that will be consistent with the ten elements of AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks specified in NUREG-2191 (GALL-SLR), as modified by SLR-ISG-2021-02-MECHANICAL, Updated Aging Management Criteria for Mechanical Portions of the Subsequent License Renewal Guidance with the following exceptions [not related to the subject RAI].
GALL-SLR Report AMP XI.M42 states AMP XI.M38, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components, AMP XI.M20, Open-Cycle Cooling Water System, or AMP XI.M21A, Closed Treated Water Systems, are acceptable alternatives to the inspections recommended in AMP XI.M42 for internal coatings when the following six conditions are met: (1) loss of coating or lining integrity cannot result in downstream effects; (2) the components only CLB [current licensing basis] intended function is leakage boundary (spatial) or structural integrity (attached); (3) the internal environment does not contain chemical compounds that could cause accelerated corrosion; (4) the internal environment would not promote microbiologically influenced corrosion of the base metal; (5) the coated/lined components are not located in the vicinity of uncoated components that could cause a galvanic couple to exist; and (6) the design for the component did not credit the coating/lining (e.g., the corrosion allowance was not zero).
At Oconee, the following programs will be used to manage loss of coating or lining integrity in lieu of the Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks program:
- The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program will manage the following internally-coated components: (a) drain pans cited in SLRA Table 3.3.2-29, Auxiliary Systems - Ventilation Systems - Aging Management Evaluation; (b) package steam fired water heater tank cited in SLRA Table 3.3.2-36, Auxiliary Systems - Plant Drinking Water System - Aging Management Evaluation; and (c) feedwater pump turbine oil and main turbine oil tanks cited in SLRA Table 3.3.2-30, Auxiliary Systems - Lube Oil System - Aging Management Evaluation.
1
Oconee SLRA - RAI B2.1.27-1
- The Water Chemistry and One Time Inspection programs will manage the internally-coated powdex and slurry tanks cited in SLRA Table 3.4.2-1, Steam and Power Conversion Systems - Condensate System - Aging Management Evaluation.
- The Open Cycle Cooling Water program will manage the following internally-coated components: (1) main condenser waterbox and tubesheet cited in SLRA Table 3.4.2-1; and (2) main turbine oil tank oil cooler heat exchanger head cited in SLRA Table 3.3.2-30.
Issue:
- 1. GALL-SLR Report AMP XI.M42 states that AMPs XI.M38, XI.M20, and XI.M21A are acceptable alternatives to the inspections recommended in AMP XI.M42 when six conditions are met. The staff seeks additional clarification regarding how the six conditions to utilize an alternative AMP are met for the components cited in the Background section above (where Oconee has elected to use an alternative AMP to manage loss of coating integrity).
- 2. As noted above, GALL-SLR Report AMP XI.M42 states various periodic internal surface inspection programs (i.e., AMPs XI.M38, XI.M20, and XI.M21A) can be used in lieu of AMP XI.M42 provided certain conditions are met; however, Oconee is proposing to use the One-Time Inspection and Water Chemistry programs to manage loss of coating integrity for the powdex and slurry tanks. The staff seeks additional clarification regarding the adequacy of a one-time inspection approach (in lieu of a periodic inspection approach) for these tanks.
Request:
- 1. For each of the components cited in the Background section of this RAI, provide additional information with respect to how the six conditions delineated in GALL-SLR Report AMP XI.M42 to utilize an alternative AMP are met (or provide an alternative basis with respect to the adequacy of these AMPs to manage loss of coating integrity).
- 2. For the internally-coated powdex and slurry tanks cited in SLRA Table 3.4.2-1, provide additional technical justification with respect to the adequacy of a one-time inspection approach (in lieu of a periodic inspection approach) for these tanks.
2