{{#Wiki_filter:EQ': ES-1'TITLE: SI TERMINATION REV 8 PAGE 1 of 25 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE PLANT SUPERINTENDENT 3-Q4-'79 EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:~'304080i67.9'30330
{{#Wiki_filter:EQ':           TITLE:
'.".PDR" ADOCK 05000244 P,",,".''...','DR:  
REV  8 ES-1   '                         SI TERMINATION PAGE 1 of 25 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE PLANT SUPERINTENDENT 3-Q4-   '79 EFFECTIVE DATE CATEGORY   1.0 REVIEWED BY:
''l ES-1.1 SI TERMINATION REV: 8 PAGE 2 of 25 A.PURPOSE-This procedure provides the necessary instructions to terminate safety injection and stabilize plant conditions.
~'304080i67.9'30330
B.ENTRY CONDITIONS/SYMPTOMS 1.ENTRY CONDITIONS
            "        05000244
-This procedure is entered from: a.E-O, REACTOR TRIP OR SAFETY INJECTION, and E-1, LOSS OF REACTOR OR SECONDARY COOLANT'hen specified termination criteria are satisfied.
'.". PDR     ADOCK P,",,". ''...',     'DR:
b.FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK/after secondary heat sink has been reestablished and SI has been terminated.


EOP: ES-1.1 TITLE$SI TERMINATION REV: 8 PAGE 3 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET>SELECTED SW PUMPS AND,ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
  '
NOTE: o FOLDOUT page should be open AND monitored periodically.
'l
o Critical Safety Function Status Trees should be monitored (Refer to Appendix I for Red Path Summary.o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+R/hr.1 Reset SI t 2 Reset CI: a.Depress CI reset pushbutton b.Verify annunciator A-26, CNMT ISOLATION-'XTINGUISHED b.Perform the following:
1)Reset SI.2)Depress CI reset pushbutton.
3 Maintain PRZR Pressure Between 1800 PSIG And 2235 PSIG o Reset PRZR heaters o Use normal PRZR spray


EOP: ES-1.1 SI TERMINATION REV: 8 PAGE 4 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Verify Adequate SW Flow: a.Check at least two SW pumps-RUNNING b.Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)a.Manually start SW pumps as power supply permits (258 kw each).IF less than two SW pumps running, THEN perform the following:
REV: 8 ES-1.1                       SI TERMINATION PAGE 2 of 25 A. PURPOSE  - This procedure provides the necessary instructions to terminate safety injection and stabilize plant conditions.
l)Ensure SW isolation.
B. ENTRY CONDITIONS/SYMPTOMS
2)Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-l).3)Go to Step 7.
: 1. ENTRY CONDITIONS  This  procedure is entered        from:
~~
: a. E-O, REACTOR TRIP  OR SAFETY INJECTION,        and E-1, LOSS OF REACTOR OR SECONDARY specified termination criteria are satisfied.
EOP: ES-1.1 TITLE: SI TERMINATION REV'PAGE 5 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 5 Establish IA to CNMT: a.Verify non-safeguards busses energized from offsite power o Bus 13 normal feed-CLOSED-OR-o Bus 15 normal feed-CLOSED b.Verify SW isolation valves to turbine building-OPEN+MOV-4613 and MOV-4670~MOV-4614 and MOV-4664 c.Verify at least two air compressors
COOLANT'hen
-RUNNING d.Check IA supply: o Pressure-GREATER THAN 60 PSIG o ,Pressure-STABLE OR INCREASING e.Reset both trains of XY relays for IA to CNMT AOV-5392 f.Verify IA to CNMT AOV-5392-OPEN a.Perform the following:
: b. FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK/
1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie'Bus 15 to Bus 16 tie 2)Verify adequate emergency D/G capacity to run air compressors (75 kw each).IF NOT, THEN evaluate if CNMT RECIRC fans should be stopped (Refer to Attachment CNMT RECIRC FANS), 3)WHEN bus 15 restored, THEN reset control room lighting.b.Manually align valves.c.Manually start air compressors as power supply permits (75 kw each).IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.
after secondary heat sink has been reestablished and SI has been terminated.
d.Perform the following:
1)Continue attempts to restore IA (Refer to AP-IA.1, LOSS OF INSTRUMENT AIR).2)Continue with Step 6.WHEN IA restored, THEN do Steps 5e and f.
I j I EOP: ES-1.1 SI TERMINATION REV: 8 PAGE 6 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 6 Check If Charging Flow Has Been Established:
a.Charging pumps-ANY RUNNING a.Perform the following:
1)IF CCW flow is lost to any.RCP thermal barrier~O any RCP¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal in]ection needle valve(s)to affected RCP:~RCP A, V-300A~RCP B, V-300B 2)Ensure HCV-142 open, demand at 0%.b.Charging pump suction aligned to RWST: o LCV-112B-OPEN o LCV-112C-CLOSED.b.Manually align valves as necessary.
IF LCV-112B can NOT be opened, THEN perform the following:
1)Verify charging pump A NOT running and place in PULL STOP.2)Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).3)WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).c.Start charging pumps as necessary and adjust charging flow to restore PRZR level 4 l EOP: ES-1.1 SI TERMINATION REV: 8 PAGE 7 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Stop SI And RHR Pumps And Place In AUTO*8 Monitor SI Reinitiation Criteria: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SVBCOOLING b.PRZR level-GREATER THAN 5%[30%.adverse CNMT)a.Manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step l.b.Control charging flow to maintain PRZR level.IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step l.'


ES-1.1 T!TLE: SI TERMINATION REV: 8 PAGE 8 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION ALIGNING SI PUMP SUCTION TO RWST BEFORE ISOLATING BAST MAY RESULT IN BACKFLOW FROM RWST TO BASTS~9 Align SI Pump Suction To RWST: a.Close SI pump suction valves from BASTs:~MOV-826A~MOV-826B~MOV-826C~MOV-826D a.Ensure at least one valve in each flow path closed.,~MOV-826A or MOV-826B~MOV-826C or MOV-826D b.Open SI pump suction valves from RWST:~MOV-825A~.MOV-825B b.Ensure at least one valve is open.c.Operate all available SI pumps for 5 minutes to flush pump RECIRC lines d.WHEN RECIRC line flush complete, THEN consult plant staff to determine if SI lines should be flushed using Attachment SI FLUSH  
EOP:            TITLE$
REV: 8 ES-1.1                                SI TERMINATION PAGE 3  of 25 STEP      ACTION/EXPECTED RESPONSE                RESPONSE NOT OBTAINED
  *****************************************
CAUTION IF OFFSITE  POWER IS LOST AFTER SI RESET> SELECTED SW PUMPS AND,ONE CCW PUMP WILL AUTO  START  ON EMERGENCY D/G. MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
NOTE:  o  FOLDOUT page    should be open  AND monitored periodically.
o  Critical Safety Function      Status Trees should be monitored (Refer to Appendix    I for  Red Path Summary.
o  Adverse    CNMT  values should be used whenever CNMT pressure is greater than    4 psig or CNMT radiation is greater than 10+    R/hr.
1 t
Reset SI 2  Reset CI:
: a. Depress CI reset pushbutton
: b. Verify annunciator A-26,      CNMT        b. Perform the following:
ISOLATION -'XTINGUISHED
: 1) Reset SI.
: 2) Depress CI reset pushbutton.
3  Maintain    PRZR  Pressure Between 1800 PSIG And 2235 PSIG o  Reset  PRZR  heaters o  Use normal PRZR spray
 
EOP:
REV: 8 ES-1.1                            SI TERMINATION PAGE 4  of 25 STEP      ACTION/EXPECTED RESPONSE          RESPONSE  NOT OBTAINED 4 Verify Adequate      SW  Flow:
: a. Check at least two  SW pumps-      a. Manually  start SW pumps as power RUNNING                                supply permits (258 kw each).
IF less than two SW pumps running, THEN perform the following:
l) Ensure  SW isolation.
: 2) Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-l).
: 3) Go  to Step 7.
: b. Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)
 
~ ~
EOP:            TITLE:
REV' ES-1.1                                  SI TERMINATION PAGE 5    of 25 STEP      ACTION/EXPECTED RESPONSE              RESPONSE NOT OBTAINED 5 Establish IA to        CNMT:
: a. Verify non-safeguards      busses        a. Perform the      following:
energized from    offsite  power
: 1) Close non-safeguards      bus  tie o  Bus 13 normal feed - CLOSED                  breakers:
                        -OR-                                ~ Bus 13  to Bus 14  tie
                                      - CLOSED
                                                          '
Bus 15  to Bus 16  tie o  Bus 15 normal    feed
: 2)  Verify adequate    emergency D/G capacity to run air compressors    (75 kw each).
IF NOT, THEN evaluate RECIRC fans should be if  CNMT stopped (Refer to Attachment    CNMT RECIRC FANS),
: 3)  WHEN  bus 15 restored, THEN reset control room lighting.
: b. Verify  SW  isolation valves to        b. Manually align valves.
turbine building    - OPEN
          + MOV-4613 and MOV-4670
          ~ MOV-4614 and MOV-4664
: c. Verify at least two    air
                          - RUNNING
: c. Manually      start air  compressors compressors                                  as power supply      permits (75  kw each). IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.
: d. Check IA supply:                        d. Perform the following:
o  Pressure    - GREATER THAN              1) Continue attempts to restore 60 PSIG                                      IA (Refer to AP-IA.1, LOSS OF INSTRUMENT AIR).
o  ,Pressure    - STABLE  OR INCREASING                              2) Continue with Step 6. WHEN IA restored, THEN do Steps 5e and  f.
: e. Reset both    trains of  XY  relays for IA to CNMT AOV-5392
: f. Verify IA to CNMT AOV-5392        - OPEN
 
I j I
 
EOP:
REV: 8 ES-1. 1                          SI TERMINATION PAGE 6    of 25 STEP      ACTION/EXPECTED RESPONSE          RESPONSE NOT OBTAINED 6  Check Been If Charging Established:
Flow Has
: a. Charging pumps -  ANY RUNNING      a. Perform the following:
: 1)  IF  CCW  flow is lost to any
                                                      .RCP  thermal barrier  ~O  any RCP ¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal in]ection needle valve(s) to affected  RCP:
                                                        ~ RCP  A, V-300A
                                                        ~ RCP  B, V-300B
: 2) Ensure HCV-142 open, demand at  0%.
: b. Charging pump  suction aligned to  .b. Manually    align valves  as RWST:                                  necessary.
o  LCV-112B - OPEN                      IF  LCV-112B can NOT be opened, THEN  perform the following:
o  LCV-112C - CLOSED
: 1)  Verify charging    pump A NOT running and place    in PULL STOP.
: 2) Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).
: 3)  WHEN  V-358 open,  THEN  direct AO  to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).
: c. Start charging pumps as necessary and adjust charging flow to restore PRZR level
 
4 l EOP:
REV: 8 ES-1.1                             SI TERMINATION PAGE 7    of 25 STEP      ACTION/EXPECTED RESPONSE          RESPONSE  NOT OBTAINED 7  Stop SI And RHR Pumps And Place In AUTO
* 8 Monitor SI Reinitiation Criteria:
: a. RCS  subcooling based on core      a. Manually operate SI pumps as exit  T/Cs -  GREATER THAN O'          necessary and go to E-l, LOSS      OF USING FIGURE MIN SVBCOOLING            REACTOR OR SECONDARY COOLANT, Step  l.
: b. PRZR  level - GREATER THAN  5%      b. Control charging flow to
[30%. adverse CNMT)                    maintain PRZR level.
IF  PRZR  level  can  NOT  be maintained,  THEN  manually operate SI  pumps as necessary and go  to E-l,  LOSS OF REACTOR OR SECONDARY COOLANT,      Step l.'
 
T!TLE:
REV: 8 ES-1.1                              SI TERMINATION PAGE 8 of 25 STEP       ACTION/EXPECTED RESPONSE               RESPONSE NOT OBTAINED
*****************************************
CAUTION ALIGNING SI PUMP SUCTION TO RWST BEFORE ISOLATING BAST MAY RESULT IN BACKFLOW FROM RWST TO BASTS   ~
9 Align SI     Pump   Suction   To RWST:
: a. Close SI pump suction valves             a. Ensure   at least one valve in from BASTs:                                  each flow path closed.,
      ~ MOV-826A                                 ~ MOV-826A  or MOV-826B
      ~  MOV-826B                                  ~ MOV-826C or MOV-826D
      ~  MOV-826C
      ~  MOV-826D
: b. Open SI   pump   suction valves from     b. Ensure at least one valve is RWST:                                       open.
      ~ MOV-825A
      ~. MOV-825B
: c. Operate all available SI pumps for 5 minutes to flush pump RECIRC   lines
: d. WHEN RECIRC   line flush complete, THEN consult plant staff to determine   if SI lines should be flushed using Attachment SI FLUSH
 
EOP:
REV: 8 ES-1.1                              SI TERMINATION PAGE 9  of 25 STEP      ACTION/EXPECTED RESPONSE            RESPONSE NOT OBTAINED
*10  Monitor Be If Stopped:
CNMT    Spray Should
: a. CNMT  spray pumps -  RUNNING        a. Go to Step 11.
: b. Check  CNMT  pressure -  LESS THAN    b. Continue with Step 11. WHEN 4 PSIG                                    CNMT pressure less than 4 psig, THEN do Steps 10c through f.
: c. Reset  CNMT  spray
: d. Check  NaOH  tank outlet valves      d. Place  NaOH tank outlet valve CLOSED                                    controllers to  MANUAL and close valves.
          ~ AOV-836A
          ~ AOV-836B
: e. Stop  CNMT  spray pumps and place in AUTO
: f. Close  CNMT  spray  pump discharge valves
          ~ MOV-860A
          ~ MOV-860B
          ~ MOV-860C
          ~ MOV-860D
 
10 C '
EOP:            1'! TLE:
REV: 8 ES-1.1                                SI TERMINATION PAGE 10  of 25 STEP      ACTION/EXPECTED RESPONSE              RESPONSE NOT OBTAINED ll Verify    MRPI Indicates  ALL CONTROL AND SHUTDOWN RODS ON IF  one  or more control rods NOT fully inserted,    THEN perform the BOTTOM                                    following:
: a. Place  RMW  mode selector switch to  BORATE.
: b. Ad)ust boric acid flow control valve, FCV-110A, for desired flowrate.
c, Set boric acid integrator to desired amount (175 gallons for each control rod not fully inserted).
: d. Place  RMW control to start and verify flow. IF flow can NOT be established,  THEN refer to ER-CVCS.1, REACTOR MAKEUP CONTROL MALFUNCTION.
12  Establish Condenser Steam Dump Pressure Control:
: a. Verify condenser available:            a. Place S/G    ARV controllers in AUTO  at desired pressure and  go o  Any MSIV -      OPEN                    to Step 13.
o  Annunciator G-15,      STEAM DUMP ARMED      - LIT
: b. Ad)ust..condenser    steam dump cont'roller    HC-484 to desired pressure      and verify in AUTO.
: c. Place steam dump mode selector switch to MANUAL.
 
k 41
 
flat            TlTLft 8
REV ES-1.1                            SI TERMINATION PAGE 11    of 25 STEP      ACTION/EXPECTED RESPONSE          RESPONSE NOT OBTAINED 13  Verify Adequate    SW  Flow To CCW  Hx:
: a. Verify at least two  SW pumps-      a. Manually start pumps as power RUNNING                                  supply permits (258 kw each).
IF less than two SW pumps can be
                                                  'perated, THEN go to Step 19.
: b. Verify AUX BLDG SW  isolation      b. Establish SW to AUX BLDG (Refer valves - OPEN                            to Attachment AUX BLDG SW).
Continue with Step 19, WHEN SW
          ~ MOV-4615 and MOV-4734                  restored to AUX BLDG; THEN do
          ~ MOV-4616 and MOV-4735                  Steps 13c through 18.
: c. Verify CNMT RECIRC fan              c. Manually  start  an additional  SW annunciator C-2, HIGH                  pump as power  supply permits TEMPERATURE ALARM - EXTINGUISHED        (258 kw each),


EOP: ES-1.1 SI TERMINATION REV: 8 PAGE 9 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*10 Monitor If CNMT Spray Should Be Stopped: a.CNMT spray pumps-RUNNING b.Check CNMT pressure-LESS THAN 4 PSIG c.Reset CNMT spray d.Check NaOH tank outlet valves CLOSED~AOV-836A~AOV-836B a.Go to Step 11.b.Continue with Step 11.WHEN CNMT pressure less than 4 psig, THEN do Steps 10c through f.d.Place NaOH tank outlet valve controllers to MANUAL and close valves.e.Stop CNMT spray pumps and place in AUTO f.Close CNMT spray pump discharge valves~MOV-860A~MOV-860B~MOV-860C~MOV-860D 10 C' EOP: ES-1.1 1'!TLE: SI TERMINATION REV: 8 PAGE 10 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED ll Verify MRPI Indicates-ALL CONTROL AND SHUTDOWN RODS ON BOTTOM IF one or more control rods NOT fully inserted, THEN perform the following:
a.Place RMW mode selector switch to BORATE.b.Ad)ust boric acid flow control valve, FCV-110A, for desired flowrate.c, Set boric acid integrator to desired amount (175 gallons for each control rod not fully inserted).
d.Place RMW control to start and verify flow.IF flow can NOT be established, THEN refer to ER-CVCS.1, REACTOR MAKEUP CONTROL MALFUNCTION.
12 Establish Condenser Steam Dump Pressure Control: a.Verify condenser available:
o Any MSIV-OPEN o Annunciator G-15, STEAM DUMP ARMED-LIT a.Place S/G ARV controllers in AUTO at desired pressure and go to Step 13.b.Ad)ust..condenser steam dump cont'roller HC-484 to desired pressure and verify in AUTO.c.Place steam dump mode selector switch to MANUAL.
k 41 flat ES-1.1 TlTLf t SI TERMINATION REV 8 PAGE 11 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Verify Adequate SW Flow To CCW Hx: a.Verify at least two SW pumps-RUNNING b.Verify AUX BLDG SW isolation valves-OPEN~MOV-4615 and MOV-4734~MOV-4616 and MOV-4735 c.Verify CNMT RECIRC fan annunciator C-2, HIGH TEMPERATURE ALARM-EXTINGUISHED a.Manually start pumps as power supply permits (258 kw each).IF less than two SW pumps can be'perated, THEN go to Step 19.b.Establish SW to AUX BLDG (Refer to Attachment AUX BLDG SW).Continue with Step 19, WHEN SW restored to AUX BLDG;THEN do Steps 13c through 18.c.Manually start an additional SW pump as power supply permits (258 kw each),
il 1 I''
il 1 I''
E(P: ES-1'TITLE: SI TERMINATION REV 8 PAGE 12 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 14 Check If Normal CVCS Operation Can Be Established a.Verify IA restored: o IA to CNMT (AOV-5392)
-OPEN o IA pressure-GREATER THAN 60 PSIG a.Continue with Step 19.WHEN IA can be restored, THEN do Steps 14 through 18.b.Verify instrument bus D-ENERGIZED b.Energize MCC B.IF MCC B NOT available, THEN perform the following:
c.CCW pumps-ANY RUNNING 1)Verify MCC A energized.
2)Place instrument bus D on maintenance supply.c.Perform the following:
1)IF any RCP¹1 seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected RCP(s),~RCP A, MOV-749A and MOV-759A~RCP B, MOV-749B and MOV-759B d.Charging pump-ANY RUNNING 2)Manually start one CCW pump.d.Continue with Step 19.WHEN any charging pump running, THEN do Steps 15 through 18.
E h t II EOP 0 ES-1.1 TITLE: SI TERMINATION REV: 8 PAGE 13 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 15 Verify PRZR Level-GREATER THAN 134[404 adverse CNMT]Continue with Step 17.WHEN PRZR level increases to greater than 13%[40%adverse CNMT], THEN do Step 16.16 Establish Normal Letdown: a.Establish charging line flow to REGEN Hx-GREATER THAN 20 GPM b.Place the following switches to CLOSE:~Letdown orifice valves (AOV-200A, AOV-200B, and AOV-202)~AOV-371, letdown isolation valve~AOV-427, loop B cold leg to REGEN Hx c.Place letdown controllers in MANUAL at 35%open~TCV-130~PCV-135 d.Reset both trains of XY relays for AOV-371 and AOV-427 e.Open AOV-371 and AOV-427 IF RCP seal return has been established, THEN establish excess letdown as follows: o Place excess letdown divert valve, AOV-312, to NORMAL.o Ensure CCW from excess letdown open, (AOV-745).
o Open excess letdown isolation valve AOV-310.o Slowly open HCV-123 to maintain excess letdown temperature less than 195'F and pressure less than 100 psig.o Adjust charging pump speed as necessary.
IF RCP seal return NOT established, THEN consult Plant Staff to determine if excess letdown should be placed in service.f.Open letdown orifice valves as necessary g.Place TCV-130 in AUTO at 105'F h.Place PCV-135 in AUTO at 250 psig i.Adjust charging.pump speed and HCV-142 as necessary to control PRZR level M W EOP: ES-1 1 SI TERMINATION REV: 8 PAGE 14 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check VCT Makeup System: a.BAST levels-ANY GREATER THAN 5%b.Check Annunciator B-23, BORIC ACID TANK LO LO LEVEL-EXTINGUISHED a.Go to Step 18.b.Perform the following:
1)Adjust boric acid flow control valve to required'flow from table.BAST LEVEL<10'0-15%15-20$>20%BORIC ACID FLOW (GPM)4.5 6.7 8.9 10.0 c.Adjust boric acid flow control valve in AUTO to 4.5 gpm d.Verify the following:
'h 1)RMW mode selector switch in AUTO 2)RMW control armed-RED LIGHT LIT e.Check VCT level: o Level-GREATER THAN 20%-OR-o Level-STABLE OR INCREASING A v*2)Go to Step 17d.d.Adjust controls as necessary.
e.Manually increase VCT makeup flow as follows: 1)Ensure BA transfer pumps and RMW pumps running.IF NOT, THEN dispatch AO to locally reset MCC C and MCC D UV lockouts as necessary.
2)Place RMW flow control valve HCV-ill in MANUAL and increase RMW flow.3)Increase boric acid flow as necessary.
I EOP I ES-1.1 TITLE: SI TERMINATION REV: 8 PAGE 15 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Check Charging Pump Suction Aligned To VCT: a.VCT level-GREATER THAN 20%a.IF VCT level can NOT be maintained greater than 5$, THEN perform the following:
1)Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed b.Verify charging pumps aligned to VCT o LCV-112C-OPEN o LCV-112B-CLOSED 2)Continue with Step 19.WHEN VCT level greater than 40%, THEN do Step 18b, b.Manually align valves as necessary.
19 Check RCS Hot Leg Temperatures
-STABLE Control steam dump and total feed flow as necessary to stabilize RCS temperature.
i
,ES-1 1 SI TERMINATION REV: 8 PAGE 16 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o WHEN using a PRZR PORV, THEN select one with an operable block valve.o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.20 Control PRZR Heaters And Operate Normal Spray To Stabilize RCS Pressure IF normal spray NOT available and letdown is in service, THEN perform the following:
a.Verify spray line fluid to PRZR AT less than 320'F.'IF NOT, THEN control pressure using one PRZR PORV and go to Step 21.b.Control pressure using auxiliary spray.IF auxiliary spray NOT available, THEN use one PRZR PORV.*****************************************CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).NOTE: TDAFW pump flow control valves fail open on loss of IA.*21 Monitor.-Intact S/G Levels: a, Narrow range level-GREATER THAN'%'25%
adverse CNMT]b.Control feed flow to maintain narrow range level between 17%[25%adverse CNMT]and 50%a.Maintain total feed flow greater than 200 gpm until narrow range level greater than 5%[25%adverse CNMT]in at least one S/G.b.IF narrow range level in any S/G continues to increase, THEN stop feed flow to that S/G.


EOP: ES-1'SI TERMINATION REV: 8 PAGE 17 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: SW should be aligned-to CCW Hxs before restoring RCP seal cooling.22 Check RCP Cooling: a.Check CCW to RCPs: Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).o Annunciator A-7, RCP lA CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED b.Check RCP seal injection:
E(P:            TITLE:
o Labyrinth seal D/Ps-GREATER THAN 15 INCHES WATER-OR-o RCP seal injection flow to each RCP-GREATER THAN 6 GPM
REV    8 ES-1 '                             SI TERMINATION PAGE 12    of 25 STEP     ACTION/EXPECTED RESPONSE             RESPONSE NOT OBTAINED 14  Check Operation If Normal      CVCS Can Be Established
: a. Verify IA restored:                   a. Continue with Step 19.        WHEN  IA can be    restored,  THEN do  Steps o  IA to   CNMT (AOV-5392) - OPEN      14 through 18.
o   IA pressure -   GREATER THAN 60 PSIG
: b. Verify instrument bus    D-         b. Energize    MCC  B. IF MCC B NOT ENERGIZED                                available,    THEN  perform the following:
: 1) Verify MCC    A energized.
: 2) Place instrument bus      D on maintenance supply.
: c. CCW  pumps - ANY RUNNING              c. Perform the following:
: 1) IF any    RCP &#xb9;1 seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected      RCP(s),
                                                        ~ RCP  A, MOV-749A and MOV-759A
                                                        ~ RCP  B, MOV-749B and MOV-759B
: 2) Manually    start  one  CCW pump.
: d. Charging pump -     ANY RUNNING      d. Continue with Step 19.        WHEN  any charging  pump  running,  THEN do Steps 15    through 18.


EOPs ES-1'SI TERMINATION REV: 8 PAGE 18 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 23 Check If Seal Return Flow.Should Be Established:
E h
a.Verify RCP&#xb9;1 seal outlet temperature
t II
-LESS THAN 235'F b.Verify RCP seal outlet valves OPEN~AOV-270A~AOV-270B a.Go to Step 24.b.Manually open valves as necessary.
c.Reset both trains of XY relays for RCP seal return isolation valve MOV-313 d.Open RCP seal return isolation valve MOV-313 e.Verify RCP&#xb9;1 seal leakoff flow LESS THAN 5.5 GPM d."Perform the following:
1)Place MOV-313 switch to OPEN.2)Dispatch AO with key to RWST gate to locally open MOV-313.e.IF any RCP seal leakoff flow greater than 5.5 gpm THEN: o Close the affected RCP seal discharge valve.~RCP A, AOV-270A~RCP"B, AOV-270B f.Verify RCP&#xb9;1 seal leakoff flow GREATER THAN,0.25 GPM o Trip the affected RCP.IF both RCP seal discharge valves are shut, THEN go to Step 24.'.Refer to AP-RCP.1, RCP SEAL MALFUNCTION.


EN>I ES-1.1 TITLE: SI TERMINATION REV: 8 PAGE 19 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 24 Verify All AC Busses-ENERGIZED BY OFFSITE POWER o Normal feed breakers to all 480 volt busses-CLOSED Perform the following:
EOP 0            TITLE:
a.IF any AC emergency bus normal feed'breaker open, THEN ensure associated D/G breaker closed.o 480 volt bus voltage-GREATER THAN 420 VOLTS o Emergency D/G output breakers-OPEN-b.Perform the following as necessary:
REV: 8 ES-1.1                                 SI TERMINATION PAGE 13    of 25 STEP       ACTION/EXPECTED RESPONSE               RESPONSE NOT OBTAINED 15 Verify PRZR Level -         GREATER        Continue with Step 17. WHEN PRZR THAN 134      [404 adverse      CNMT]        level increases to greater than 13%
1)Close non-safeguards bus tie breakers:~Bus 13 to Bus 14 tie~Bus 15 to Bus 16 tie 2)Reset Bus 13 and Bus 15 lighting breakers.3)Dispatch AO to locally reset and start two IA compressors, 4)Place the following pumps in PULL STOP:~EH pumps~Turning gear oil pump~HP seal oil backup pump 5)Restore power to MCCs:~A from Bus 13~B from Bus 15~E from Bus 15~F from Bus 15 6)Start CNMT RECIRC fans as necessary.
[40% adverse CNMT], THEN do Step 16.
7)Refer to Attachment SI/UV for other equipment lost with loss of offsite power.c.Try to restore offsite power to all AC busses (Refer to ER-ELEC.l>
16 Establish Normal Letdown:                    IF RCP seal return has been established, THEN establish excess
RESTORATION OF OFFSITE POWER).  
: a. Establish charging    line flow to      letdown as follows:
REGEN Hx - GREATER THAN 20 GPM o   Place excess letdown    divert
: b. Place the following switches to              valve, AOV-312, to    NORMAL.
CLOSE:
o  Ensure CCW from excess letdown
          ~ Letdown    orifice valves                  open, (AOV-745).
(AOV-200A, AOV-200B, and AOV-202)                               o  Open excess  letdown isolation
          ~ AOV-371, letdown isolation                valve AOV-310.
valve
          ~ AOV-427, loop    B cold leg to       o  Slowly open HCV-123 to maintain REGEN Hx                                  excess letdown temperature less than 195'F and pressure less
: c. Place letdown controllers in                 than 100 psig.
MANUAL at 35% open o  Adjust charging    pump speed  as
          ~ TCV-130                                    necessary.
          ~ PCV-135 IF RCP seal return NOT      established,
: d. Reset both    trains of  XY  relays    THEN consult Plant    Staff to for  AOV-371 and AOV-427                determine  if excess  letdown  should be placed  in  service.
: e. Open AOV-371 and AOV-427
: f. Open letdown    orifice valves    as necessary
: g. Place TCV-130    in AUTO  at 105'F
: h. Place PCV-135 in    AUTO  at  250  psig
: i. Adjust charging. pump speed    and HCV-142 as necessary      to control PRZR  level


EOP$ES-1.1 TLTLE$SI TERMINATION REV: 8 PAGE 20 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.
M W
25 Check If Source Range Channels Should Be Energized:
a.Source range channels-DEENERGIZED a.Go.to Step 25e.b.Check intermediate range flux-EITHER CHANNEL LESS THAN 10 10 AMPS b.Perform the following:
1)IF neither intermediate range channel is decreasing, THEN initiate boration.c.Check the following:
o Both intermediate range channels-LESS THAN 10 AMPS 2)Continue with Step 26.WHEN flux is LESS THAN 10-10~ps on any operable channel, THEN do Steps 25c, d and e.c.Continue with step.26.WHEN either condition met, THEN do Steps 25d and e.-OR-o Greater than 20 minutes since reactor trip d.Verify source range detectors-ENERGIZED d.Manually energize source range detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).IF source ranges can NOT be restored, THEN refer to ER-NIS.l, SR MAR'tJNCTION, and go to Step 26.e.Transfer Rk-45 recorder to one source range and one intermediate range channel V
EOP: ES-1.1 SI TERMINATION REV 8 PAGE 21 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 26 Check If Emergency D/Gs Should Be Stopped: a.Verify AC emergency busses energized by offsite power: o Emergency D/G output breakers OPEN a.Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).o AC emergency bus voltage-GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers-CLOSED b.Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)
II k I EOP: ES-1.1 TITLE: SI TERMINATION REV: 8 PAGE 22 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************************************CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST>THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATION.
27 Check RCP Status-AT LEAST ONE RUNNING Perform the following:
a.Establish conditions for starting an RCP;o.Verify bus 11A or 11B energized.
o Refer to Attachment RCP START.b.Start one RCP.IF an RCP can NOT be started, THEN verify natural circulation (Refer to Attachment NC).IF natural circulation NOT verified, THEN increase dumping steam from intact S/Gs.
'I Na EOP: ES-1.1 TITLE: SI TERMINATION REV'PAGE 23 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 28 Establish Normal Shutdown Alignment:
a.Check condenser-AVAILABLE a.Dispatch AO to perform Attachment SD-2.b.Perform the following:
o Open generator disconnects
~1G13A71~9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o" Rotate reheater steam supply controller cam to close valves o Place reheater dump valve switches to HAND o Stop all but one condensate pump c.Verify adequate Rx head cooling:')
Check IA to CNMT-AVAILABLE 2)Verify at least one control rod shroud fan-RUWING 1)Go to Step 29.2)Manually start one fan as power supply permits (45 kw)3)Verify one Rx compartment
~cooling fan-RUNNING 3)Perform the following:
o Dispatch AO to reset UV relays at MCC C and MCC D.o Manually start one fan as power supply permits (23 kw)d.Verify Attachment SD-1-COMPLETE


EOP: ES-1.1 SI TERMINATION REV: 8 PAGE 24 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 29 Maintain Plant Conditions Stable: a.RCS pressure-BETWEEN 1800 PSIG AND 2235 PSIG b.PRZR level-BETWEEN 20%AND 30$c.Intact S/G narrow range levels-BETWEEN 17%AND 39%d.RCS cold leg temperature
EOP:
-STABLE a.Control PRZR heaters and spray as necessary.
REV: 8 ES-1 1                                   SI TERMINATION PAGE 14  of 25 STEP     ACTION/EXPECTED RESPONSE                 RESPONSE NOT OBTAINED 17  Check VCT Makeup System:
b.Control charging as necessary.
: a. BAST    levels    - ANY GREATER THAN  5% a. Go  to Step 18.
c.Control S/G feed flow as necessary.
: b. Check Annunciator B-23,        BORIC    b. Perform the following:
d.Control dumping steam as necessary.
ACID TANK LO LO LEVEL-EXTINGUISHED                                  1) Adjust boric acid flow control valve to required
IF cooldown continues, THEN close both MSIVs.*30 Monitor SI Reinitiation Criteria:.
                                                            'flow from table.
a.RCS subcooling based on core exit T/Cs-GREATER THAN O'USING FIGURE MIN SUBCOOLING b.PRZR level-GREATER THAN 5%[30%adverse CNMT]a.Manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step l.b.Control charging flow to maintain PRZR level.IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step l.  
BAST          BORIC ACID LEVEL          FLOW (GPM)
                                                              <10'0-15%
4.5 6.7 15-20$              8.9
                                                              >20%              10.0
: 2)  Go    to Step 17d.
: c. Adjust boric acid flow control valve in AUTO to 4.5 gpm
: d. Verify the following:                    d. Adjust controls as necessary.
              'h
: 1) RMW      mode  selector switch in AUTO
: 2) RMW      control  armed - RED LIGHT LIT
: e. Check    VCT  level:                    e. Manually increase        VCT makeup flow    as    follows:
o  Level -       GREATER THAN 20%
: 1) Ensure BA transfer        pumps and
                            -OR-                            RMW    pumps  running. IF NOT, THEN     dispatch AO to locally o  Level -        STABLE OR INCREASING            reset MCC C and MCC D UV lockouts as necessary.
A v *
: 2) Place RMW flow control valve HCV-ill in MANUAL and increase RMW flow.
: 3) Increase boric acid flow as necessary.


EOP!ES-1 1 T1TLE: SI TERMINATION REV: 8 PAGE 25 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT'OBTAINED 31 Go To Procedure 0-2.1, NORMAL SHUTDOWN TO HOT SHUTDOWN-END-  
I EOP I            TITLE:
REV: 8 ES-1.1                             SI TERMINATION PAGE 15  of 25 STEP     ACTION/EXPECTED RESPONSE           RESPONSE NOT OBTAINED 18  Check Charging Pump Suction Aligned    To VCT:
: a. VCT level  - GREATER THAN 20%      a. IF  VCT  level  can NOT  be maintained greater than 5$ ,    THEN perform the following:
: 1) Ensure charging pump suction aligned to  RWST o  LCV-112B open o  LCV-112C  closed
: 2) Continue    with Step 19. WHEN VCT level greater    than 40%,
THEN do Step 18b,
: b. Verify charging  pumps aligned to  b. Manually align valves as VCT                                      necessary.
o  LCV-112C - OPEN o  LCV-112B - CLOSED 19  Check RCS Hot Leg                        Control steam dump and total feed Temperatures - STABLE                    flow as necessary to stabilize RCS temperature.


EOPs ES-1 1 TjTLE: SI TERMINATION REV: 8 PAGE 1 of 1 ES-1.1 APPENDIX LIST'ITLE 1)RED PATH  
i REV: 8
,ES-1 1                                SI TERMINATION PAGE 16  of 25 STEP      ACTION/EXPECTED RESPONSE                  RESPONSE NOT OBTAINED NOTE:  o  WHEN  using a  PRZR PORV, THEN  select  one  with  an operable  block valve.
o  If auxiliary spray    is in use, spray flow may      be increased by AOV-294 and normal PRZR spray valves.
closing normal charging valve 20  Control    PRZR Heaters And                    IF normal spray NOT available and Operate Normal Spray To                        letdown is in service, THEN perform Stabilize RCS Pressure                        the following:
: a. Verify spray line fluid to PRZR AT less than 320'F. 'IF NOT, THEN control pressure using one PRZR PORV    and go  to Step 21.
: b. Control pressure using auxiliary spray.
IF auxiliary spray      NOT available, THEN  use one PRZR PORV.
*****************************************
CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS  WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).
NOTE:  TDAFW pump    flow control valves    fail open    on loss  of IA.
*21  Monitor.-Intact      S/G  Levels:
a, Narrow range    level - GREATER            a. Maintain    total feed flow greater THAN'%'25% adverse      CNMT]                  than 200    gpm until narrow range level greater than 5% [25%
adverse  CNMT] in at least one S/G.
: b. Control feed flow to maintain              b. IF narrow range level in any S/G narrow range level between 17%                  continues to increase, THEN stop
[25%  adverse  CNMT]  and  50%                feed flow to that S/G.
 
EOP:
REV: 8 ES-1  '                              SI  TERMINATION PAGE 17  of 25 STEP      ACTION/EXPECTED RESPONSE                RESPONSE NOT OBTAINED NOTE:    SW should be aligned-to    CCW  Hxs before restoring  RCP seal cooling.
22  Check    RCP  Cooling:                        Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).
: a. Check  CCW to  RCPs:
o  Annunciator A-7,    RCP lA CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o  Annunciator A-15,    RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED
: b. Check  RCP seal injection:
o  Labyrinth seal D/Ps    - GREATER THAN 15 INCHES WATER
                        -OR-o  RCP  seal injection flow to each  RCP  -  GREATER THAN 6 GPM
 
EOPs REV: 8 ES-1   '                            SI TERMINATION PAGE 18    of 25 STEP      ACTION/EXPECTED RESPONSE            RESPONSE NOT OBTAINED 23    Check    If  Seal Return Flow.
Should Be Established:
: a. Verify RCP &#xb9;1 seal outlet            a. Go to Step 24.
temperature  - LESS THAN 235'F
: b. Verify RCP seal outlet valves        b. Manually open valves as OPEN                                    necessary.
            ~ AOV-270A
            ~ AOV-270B
: c. Reset both trains of    XY relays for  RCP  seal return isolation valve  MOV-313
: d. Open  RCP  seal return isolation    d."Perform the following:
valve  MOV-313
: 1) Place MOV-313 switch to    OPEN.
: 2) Dispatch    AO with key to  RWST gate to    locally open MOV-313.
: e. Verify RCP &#xb9;1 seal leakoff flow      e. IF any  RCP  seal leakoff flow LESS THAN  5.5 GPM                    greater than 5.5    gpm THEN:
o  Close the affected    RCP  seal discharge valve.
                                                          ~ RCP A,  AOV-270A
                                                          ~ RCP"B,  AOV-270B o  Trip the affected    RCP.
IF both RCP seal discharge valves are shut, THEN go to Step 24.
                                                                '.
: f. Verify  RCP &#xb9;1 seal  leakoff flow      Refer to AP-RCP.1,    RCP SEAL GREATER THAN,0.25 GPM                  MALFUNCTION.
 
EN>I          TITLE:
REV: 8 ES-1. 1                          SI TERMINATION PAGE 19    of 25 STEP      ACTION/EXPECTED RESPONSE          RESPONSE NOT OBTAINED 24 Verify All AC Busses                  Perform the following:
ENERGIZED BY OFFSITE POWER
: a. IF any  AC  emergency bus normal o  Normal feed breakers to  all 480      feed'breaker open, THEN ensure volt busses - CLOSED                    associated D/G breaker closed.
o  480 volt  bus voltage - GREATER    b. Perform the following as THAN 420 VOLTS                          necessary:
o  Emergency D/G  output breakers-        1) Close non-safeguards      bus tie OPEN-                                      breakers:
                                                      ~ Bus 13  to  Bus 14  tie
                                                      ~ Bus 15  to  Bus 16  tie
: 2) Reset Bus 13 and Bus 15 lighting breakers.
: 3) Dispatch AO to locally reset and start two IA compressors,
: 4) Place the following pumps        in PULL STOP:
                                                      ~ EH  pumps
                                                      ~ Turning gear oil pump
                                                      ~ HP seal oil backup pump
: 5) Restore power to MCCs:
                                                      ~ A  from  Bus  13
                                                      ~ B  from  Bus  15
                                                      ~ E from  Bus  15
                                                      ~ F from  Bus  15
: 6)  Start  CNMT RECIRC  fans as necessary.
: 7) Refer to Attachment SI/UV        for other equipment lost with loss of offsite power.
: c. Try to restore    offsite  power to all AC  busses  (Refer to ER-ELEC.l> RESTORATION OF OFFSITE POWER).
 
EOP$              TLTLE$
REV: 8 ES-1. 1                              SI  TERMINATION PAGE 20    of 25 STEP        ACTION/EXPECTED RESPONSE              RESPONSE NOT OBTAINED NOTE:    Adverse    CNMT conditions or loss of forced air cooling  may  result in failure of  NIS  detectors.
25  Check    If  Source Range Channels Should Be Energized:
: a. Source range channels-                  a. Go.to Step 25e.
DEENERGIZED
: b. Check intermediate range      flux-    b. Perform the following:
EITHER CHANNEL LESS THAN 10 10 AMPS                                  1) IF  neither intermediate range channel is decreasing,  THEN initiate boration.
: 2) Continue  with Step 26. WHEN flux is  LESS THAN  10-10 ~ps on any operable channel,    THEN do Steps 25c, d and e.
: c. Check the following:                    c. Continue with step. 26. WHEN either condition met,  THEN do o  Both intermediate range                Steps 25d and e.
channels - LESS THAN 10        AMPS
                          -OR-o  Greater than    20 minutes  since reactor  trip
: d. Verify source    range detectors-      d. Manually energize source range ENERGIZED                                  detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).
IF source ranges can NOT  be restored, THEN refer to ER-NIS.l, SR  MAR'tJNCTION, and go to Step 26.
: e. Transfer Rk-45 recorder to one source range and one intermediate range channel
 
V EOP:
REV  8 ES-1.1                              SI TERMINATION PAGE 21  of 25 STEP      ACTION/EXPECTED RESPONSE            RESPONSE NOT OBTAINED 26  Check    If Emergency Should Be Stopped:
D/Gs
: a. Verify AC  emergency busses          a. Try to restore  offsite power energized by  offsite power:            (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).
o  Emergency D/G output breakers OPEN o  AC emergency bus    voltage-GREATER THAN 420 VOLTS o  AC  emergency bus normal feed breakers -  CLOSED
: b. Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)
 
II k
I
 
EOP:            TITLE:
REV: 8 ES-1.1                            SI TERMINATION PAGE 22  of 25 STEP      ACTION/EXPECTED RESPONSE            RESPONSE  NOT OBTAINED
  *****************************************
CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST> THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATION.
27  Check RCP Status  AT LEAST            Perform the following:
ONE RUNNING
: a. Establish conditions      for starting  an RCP; o . Verify bus  11A  or  11B energized.
o  Refer to Attachment    RCP START.
: b. Start one    RCP.
IF  an RCP can NOT be    started,  THEN verify natural circulation (Refer to Attachment NC).
IF natural circulation      NOT verified,  THEN  increase dumping steam from    intact  S/Gs.
 
'I Na
 
EOP:                TITLE:
REV' ES-1.1                                              SI TERMINATION PAGE 23  of 25 STEP          ACTION/EXPECTED RESPONSE                        RESPONSE NOT OBTAINED 28  Establish Normal Shutdown Alignment:
: a. Check condenser        - AVAILABLE                  a. Dispatch AO to perform Attachment SD-2.
: b. Perform the following:
o    Open  generator disconnects
                  ~  1G13A71
                  ~  9X13A73 o    Place voltage regulator to                OFF o    Open  turbine drain valves o  "
Rotate reheater steam supply controller cam to close valves o    Place reheater dump valve switches to HAND o    Stop  all  but  one condensate pump
: c. Verify adequate        Rx head  cooling:')
Check IA    to  CNMT -  AVAILABLE                1)  Go to Step 29.
: 2)  Verify at least      one  control                  2) Manually start one fan as rod shroud fan      - RUWING                          power supply permits (45 kw)
: 3)  Verify one    Rx compartment                      3) Perform the  following:
          ~
cooling fan    - RUNNING o  Dispatch  AO  to reset  UV relays at  MCC C  and  MCC D.
o  Manually start one fan as power supply permits (23 kw)
: d. Verify Attachment      SD COMPLETE
 
EOP:
REV: 8 ES-1.1                              SI TERMINATION PAGE 24  of 25 STEP      ACTION/EXPECTED RESPONSE            RESPONSE NOT OBTAINED 29  Maintain Plant Conditions Stable:
: a. RCS  pressure -  BETWEEN 1800 PSIG  a. Control PRZR heaters and spray AND 2235 PSIG                            as necessary.
: b. PRZR  level  - BETWEEN 20% AND 30$    b. Control charging as necessary.
: c. Intact S/G narrow range    levels-    c. Control S/G feed flow as BETWEEN 17% AND 39%                      necessary.
: d. RCS  cold leg temperature  - STABLE  d. Control dumping steam as necessary. IF cooldown continues,  THEN  close both MSIVs.
*30  Monitor SI Reinitiation Criteria:.
: a. RCS  subcooling based on core        a. Manually operate SI pumps as exit  T/Cs -  GREATER THAN O'            necessary and go to E-l, LOSS    OF USING FIGURE MIN SUBCOOLING              REACTOR OR SECONDARY COOLANT, Step  l.
: b. PRZR  level  -  GREATER THAN 5%      b. Control charging flow to
[30%  adverse  CNMT]                    maintain PRZR level.
IF  PRZR level  can NOT  be maintained, THEN manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT,    Step l.
 
EOP!          T1TLE:
REV: 8 ES-1 1                          SI TERMINATION PAGE 25 of 25 STEP    ACTION/EXPECTED RESPONSE          RESPONSE NOT'OBTAINED 31  Go To  Procedure  0-2.1,  NORMAL SHUTDOWN TO HOT SHUTDOWN
                                          -END-
 
EOPs          TjTLE:
REV: 8 ES-1 1                      SI TERMINATION PAGE 1 of 1 ES-1.1 APPENDIX LIST'ITLE PAGES
: 1)   RED PATH  


==SUMMARY==
==SUMMARY==
2)FIGURE MIN SUBCOOLING 3)ATTACHMENT CNMT RECIRC 4)ATTACHMENT D/G STOP 5)ATTACHMENT NC 6)ATTACHMENT SEAL COOLING 7)ATTACHMENT RCP START 8)ATTACHMENT SD-1 9)ATTACHMENT SD-2 10)ATTACHMENT SI/UV 11)ATTACHMENT SI FLUSH 12)ATTACHMENT AUX BLDG SW 13)FOLDOUT PAGES
: 2)   FIGURE MIN SUBCOOLING
: 3)   ATTACHMENT CNMT RECIRC
: 4)   ATTACHMENT D/G STOP
: 5)   ATTACHMENT NC
: 6)   ATTACHMENT SEAL COOLING
: 7)   ATTACHMENT RCP START
: 8)   ATTACHMENT SD-1
: 9)   ATTACHMENT SD-2
: 10)   ATTACHMENT SI/UV
: 11)   ATTACHMENT SI FLUSH
: 12)   ATTACHMENT AUX BLDG SW
: 13)   FOLDOUT


ES-1.1 TITLE%SI TERMINATION REV: 8 PAGE 1 of 1 RED PATH  
TITLE%
REV: 8 ES-1. 1                         SI TERMINATION PAGE 1 of 1 RED PATH  


==SUMMARY==
==SUMMARY==
a.SUBCRITICALITY
: a. SUBCRITICALITY - Nuclear power     greater than 54
-Nuclear power greater than 54 b.CORE COOLING-Core exit T/Cs greater than 1200'F-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs)less than 434[46%adverse CNMT]c.HEAT SINK-Narrow range level in all S/Gs less than 54[254 adverse CNMT]AND total feedwater flow less than 200 gpm d..INTEGRITY
: b. CORE COOLING   - Core exit T/Cs greater than 1200'F
-Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F e.CONTAINMENT
                                          -OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs) less than 434 [46%
-CNMT pressure greater than 60 psig  
adverse CNMT]
: c. HEAT SINK   - Narrow range   level in all S/Gs less than 54
[254 adverse   CNMT] AND total feedwater flow less than   200 gpm
: d. .INTEGRITY     Cold   leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F
: e. CONTAINMENT   -   CNMT pressure greater than   60 psig
 
EOPt            T!TLE:
REV: 8 ES-F 1                              SI TERMINATION PAGE 1  of  1 FIGURE MIN SUBCOOLING NOTE:    Subcooling Margin = Saturation Temperature From Figure Below  [-] Core Exit  T/C  Indication RC S PRESSURE  (PSIG) 2500 2400 RCS PRESSURE 2300 INCREMENTS 20 PSIG 2200 2100 2000 1900 1800 1700 1600 1500 1400 SUBCOOLED 1300                          REGION 1200 1100 1000 900 800 INADEQUATE 700 SUBCOOLING 600                                                                REGION ADVERSE CNH 500 400 300 200                                        NORMAL CNHT                  TEMPERATURE INCREMENTS 10'F 100 0
200      250    300      350    400    450    500    550      600    650    700 CORE  EXIT SATURATION TEHPERATURE ('F)


EOPt ES-F 1 T!TLE: SI TERMINATION REV: 8 PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin=Saturation Temperature From Figure Below[-]Core Exit T/C Indication RC 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 S PRESSURE (PSIG)RCS PRESSURE INCREMENTS 20 PSIG SUBCOOLED REGION ADVERSE CNH NORMAL CNHT INADEQUATE SUBCOOLING REGION TEMPERATURE INCREMENTS 10'F 200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEHPERATURE
EOP:            TlTLEi REV: 8 ES-1.1                            SI TERMINATION PAGE 1 of 1 FOLDOUT PAGE 1~  SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN manually operate SI pumps as necessary and go to E-1, LOSS OF REACTOR OR SECONDARY COOLANT,    Step 1:
('F)  
o  RCS  subcooling based on core  exit    T/Cs  LESS  THAN  O'F USING FIGURE MXN SUBCOOLING OR-o  PRZR level  CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%
[304 adverse CNMT]
: 2. SI TERMINATION CRITERIA IF ALL conditions listed below occur, THEN go, to ES-1.1, SI TERMINATION, Step 1:
: a. RCS subcooling based on core exit T/Cs  GREATER THAN O'F          USING REQUIREMENTS OF FIGURE MIN SUBCOOLING
: b. Total feed flow to intact S/Gs      GREATER THAN 200 GPM OR Narrow range level in    at least
                                                  -
one  intact S/G  -  GREATER THAN 54 [254 adverse CNMT]
: c. RCS pressure:
o GREATER THAN 1625 PSIG [1825      psig adverse  CNMT]
o STABLE OR INCREASING
: d. PRZR  level  GREATER THAN 54 [30%    adverse CNMT]
3 ~  SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2,  FAULTED S/G ISOLATXON,    Step 1.
: 4. COL  "  G  RECIRCULATION SWITCHOVER CRITERION IF  RWQT  level decreases to less than    284, THEN go  to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION,        Step 1.
: 5. AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS) .
6 ~ E-3 TRANSITION CRITERIA IF any S/G level increases in an uncontrolled manner or any S/G has abnormal radiation, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step 1.


EOP: ES-1.1 TlTLEi SI TERMINATION REV: 8 PAGE 1 of 1 FOLDOUT PAGE 1~SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN manually operate SI pumps as necessary and go to E-1, LOSS OF REACTOR OR SECONDARY COOLANT, Step 1: o RCS subcooling based on core exit T/Cs-LESS THAN O'F USING FIGURE MXN SUBCOOLING OR-o PRZR level-CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%[304 adverse CNMT]2.SI TERMINATION CRITERIA IF ALL conditions listed below occur, THEN go, to ES-1.1, SI TERMINATION, Step 1: a.RCS subcooling based on core exit T/Cs-GREATER THAN O'F USING REQUIREMENTS OF FIGURE MIN SUBCOOLING b.Total feed flow to intact S/Gs-GREATER THAN 200 GPM OR-Narrow range level in at least one intact S/G-GREATER THAN 54[254 adverse CNMT]c.RCS pressure: o GREATER THAN 1625 PSIG[1825 psig adverse CNMT]o STABLE OR INCREASING d.PRZR level-GREATER THAN 54[30%adverse CNMT]3~SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2, FAULTED S/G ISOLATXON, Step 1.4.COL" G RECIRCULATION SWITCHOVER CRITERION IF RWQT level decreases to less than 284, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step 1.5.AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).6~E-3 TRANSITION CRITERIA IF any S/G level increases in an uncontrolled manner or any S/G has abnormal radiation, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step 1.
il 4}}
il 4}}

Revision as of 18:26, 29 October 2019

Rev 8 to EOP ES-1.1, SI Termination.
ML17263A200
Person / Time
Site: Ginna Constellation icon.png
Issue date: 03/24/1993
From: Marlow T
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17263A191 List:
References
ES-1.1, NUDOCS 9304080167
Download: ML17263A200 (58)


Text

EQ': TITLE:

REV 8 ES-1 ' SI TERMINATION PAGE 1 of 25 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE PLANT SUPERINTENDENT 3-Q4- '79 EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

~'304080i67.9'30330

" 05000244

'.". PDR ADOCK P,",,". ...', 'DR:

'

'l

REV: 8 ES-1.1 SI TERMINATION PAGE 2 of 25 A. PURPOSE - This procedure provides the necessary instructions to terminate safety injection and stabilize plant conditions.

B. ENTRY CONDITIONS/SYMPTOMS

1. ENTRY CONDITIONS This procedure is entered from:
a. E-O, REACTOR TRIP OR SAFETY INJECTION, and E-1, LOSS OF REACTOR OR SECONDARY specified termination criteria are satisfied.

COOLANT'hen

b. FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK/

after secondary heat sink has been reestablished and SI has been terminated.

EOP: TITLE$

REV: 8 ES-1.1 SI TERMINATION PAGE 3 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET> SELECTED SW PUMPS AND,ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G. MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

NOTE: o FOLDOUT page should be open AND monitored periodically.

o Critical Safety Function Status Trees should be monitored (Refer to Appendix I for Red Path Summary.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+ R/hr.

1 t

Reset SI 2 Reset CI:

a. Depress CI reset pushbutton
b. Verify annunciator A-26, CNMT b. Perform the following:

ISOLATION -'XTINGUISHED

1) Reset SI.
2) Depress CI reset pushbutton.

3 Maintain PRZR Pressure Between 1800 PSIG And 2235 PSIG o Reset PRZR heaters o Use normal PRZR spray

EOP:

REV: 8 ES-1.1 SI TERMINATION PAGE 4 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Verify Adequate SW Flow:

a. Check at least two SW pumps- a. Manually start SW pumps as power RUNNING supply permits (258 kw each).

IF less than two SW pumps running, THEN perform the following:

l) Ensure SW isolation.

2) Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-l).
3) Go to Step 7.
b. Dispatch AO to establish normal shutdown alignment (Refer to Attachment SD-1)

~ ~

EOP: TITLE:

REV' ES-1.1 SI TERMINATION PAGE 5 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 5 Establish IA to CNMT:

a. Verify non-safeguards busses a. Perform the following:

energized from offsite power

1) Close non-safeguards bus tie o Bus 13 normal feed - CLOSED breakers:

-OR- ~ Bus 13 to Bus 14 tie

- CLOSED

'

Bus 15 to Bus 16 tie o Bus 15 normal feed

2) Verify adequate emergency D/G capacity to run air compressors (75 kw each).

IF NOT, THEN evaluate RECIRC fans should be if CNMT stopped (Refer to Attachment CNMT RECIRC FANS),

3) WHEN bus 15 restored, THEN reset control room lighting.
b. Verify SW isolation valves to b. Manually align valves.

turbine building - OPEN

+ MOV-4613 and MOV-4670

~ MOV-4614 and MOV-4664

c. Verify at least two air

- RUNNING

c. Manually start air compressors compressors as power supply permits (75 kw each). IF air compressors can NOT be started, THEN dispatch AO to locally reset compressors as necessary.
d. Check IA supply: d. Perform the following:

o Pressure - GREATER THAN 1) Continue attempts to restore 60 PSIG IA (Refer to AP-IA.1, LOSS OF INSTRUMENT AIR).

o ,Pressure - STABLE OR INCREASING 2) Continue with Step 6. WHEN IA restored, THEN do Steps 5e and f.

e. Reset both trains of XY relays for IA to CNMT AOV-5392
f. Verify IA to CNMT AOV-5392 - OPEN

I j I

EOP:

REV: 8 ES-1. 1 SI TERMINATION PAGE 6 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 6 Check Been If Charging Established:

Flow Has

a. Charging pumps - ANY RUNNING a. Perform the following:
1) IF CCW flow is lost to any

.RCP thermal barrier ~O any RCP ¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal in]ection needle valve(s) to affected RCP:

~ RCP A, V-300A

~ RCP B, V-300B

2) Ensure HCV-142 open, demand at 0%.
b. Charging pump suction aligned to .b. Manually align valves as RWST: necessary.

o LCV-112B - OPEN IF LCV-112B can NOT be opened, THEN perform the following:

o LCV-112C - CLOSED

1) Verify charging pump A NOT running and place in PULL STOP.
2) Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).
3) WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).
c. Start charging pumps as necessary and adjust charging flow to restore PRZR level

4 l EOP:

REV: 8 ES-1.1 SI TERMINATION PAGE 7 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Stop SI And RHR Pumps And Place In AUTO

  • 8 Monitor SI Reinitiation Criteria:
a. RCS subcooling based on core a. Manually operate SI pumps as exit T/Cs - GREATER THAN O' necessary and go to E-l, LOSS OF USING FIGURE MIN SVBCOOLING REACTOR OR SECONDARY COOLANT, Step l.
b. PRZR level - GREATER THAN 5% b. Control charging flow to

[30%. adverse CNMT) maintain PRZR level.

IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step l.'

T!TLE:

REV: 8 ES-1.1 SI TERMINATION PAGE 8 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

CAUTION ALIGNING SI PUMP SUCTION TO RWST BEFORE ISOLATING BAST MAY RESULT IN BACKFLOW FROM RWST TO BASTS ~

9 Align SI Pump Suction To RWST:

a. Close SI pump suction valves a. Ensure at least one valve in from BASTs: each flow path closed.,

~ MOV-826A ~ MOV-826A or MOV-826B

~ MOV-826B ~ MOV-826C or MOV-826D

~ MOV-826C

~ MOV-826D

b. Open SI pump suction valves from b. Ensure at least one valve is RWST: open.

~ MOV-825A

~. MOV-825B

c. Operate all available SI pumps for 5 minutes to flush pump RECIRC lines
d. WHEN RECIRC line flush complete, THEN consult plant staff to determine if SI lines should be flushed using Attachment SI FLUSH

EOP:

REV: 8 ES-1.1 SI TERMINATION PAGE 9 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

  • 10 Monitor Be If Stopped:

CNMT Spray Should

a. CNMT spray pumps - RUNNING a. Go to Step 11.
b. Check CNMT pressure - LESS THAN b. Continue with Step 11. WHEN 4 PSIG CNMT pressure less than 4 psig, THEN do Steps 10c through f.
c. Reset CNMT spray
d. Check NaOH tank outlet valves d. Place NaOH tank outlet valve CLOSED controllers to MANUAL and close valves.

~ AOV-836A

~ AOV-836B

e. Stop CNMT spray pumps and place in AUTO
f. Close CNMT spray pump discharge valves

~ MOV-860A

~ MOV-860B

~ MOV-860C

~ MOV-860D

10 C '

EOP: 1'! TLE:

REV: 8 ES-1.1 SI TERMINATION PAGE 10 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED ll Verify MRPI Indicates ALL CONTROL AND SHUTDOWN RODS ON IF one or more control rods NOT fully inserted, THEN perform the BOTTOM following:

a. Place RMW mode selector switch to BORATE.
b. Ad)ust boric acid flow control valve, FCV-110A, for desired flowrate.

c, Set boric acid integrator to desired amount (175 gallons for each control rod not fully inserted).

d. Place RMW control to start and verify flow. IF flow can NOT be established, THEN refer to ER-CVCS.1, REACTOR MAKEUP CONTROL MALFUNCTION.

12 Establish Condenser Steam Dump Pressure Control:

a. Verify condenser available: a. Place S/G ARV controllers in AUTO at desired pressure and go o Any MSIV - OPEN to Step 13.

o Annunciator G-15, STEAM DUMP ARMED - LIT

b. Ad)ust..condenser steam dump cont'roller HC-484 to desired pressure and verify in AUTO.
c. Place steam dump mode selector switch to MANUAL.

k 41

flat TlTLft 8

REV ES-1.1 SI TERMINATION PAGE 11 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Verify Adequate SW Flow To CCW Hx:

a. Verify at least two SW pumps- a. Manually start pumps as power RUNNING supply permits (258 kw each).

IF less than two SW pumps can be

'perated, THEN go to Step 19.

b. Verify AUX BLDG SW isolation b. Establish SW to AUX BLDG (Refer valves - OPEN to Attachment AUX BLDG SW).

Continue with Step 19, WHEN SW

~ MOV-4615 and MOV-4734 restored to AUX BLDG; THEN do

~ MOV-4616 and MOV-4735 Steps 13c through 18.

c. Verify CNMT RECIRC fan c. Manually start an additional SW annunciator C-2, HIGH pump as power supply permits TEMPERATURE ALARM - EXTINGUISHED (258 kw each),

il 1 I

E(P: TITLE:

REV 8 ES-1 ' SI TERMINATION PAGE 12 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 14 Check Operation If Normal CVCS Can Be Established

a. Verify IA restored: a. Continue with Step 19. WHEN IA can be restored, THEN do Steps o IA to CNMT (AOV-5392) - OPEN 14 through 18.

o IA pressure - GREATER THAN 60 PSIG

b. Verify instrument bus D- b. Energize MCC B. IF MCC B NOT ENERGIZED available, THEN perform the following:
1) Verify MCC A energized.
2) Place instrument bus D on maintenance supply.
c. CCW pumps - ANY RUNNING c. Perform the following:
1) IF any RCP ¹1 seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected RCP(s),

~ RCP A, MOV-749A and MOV-759A

~ RCP B, MOV-749B and MOV-759B

2) Manually start one CCW pump.
d. Charging pump - ANY RUNNING d. Continue with Step 19. WHEN any charging pump running, THEN do Steps 15 through 18.

E h

t II

EOP 0 TITLE:

REV: 8 ES-1.1 SI TERMINATION PAGE 13 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 15 Verify PRZR Level - GREATER Continue with Step 17. WHEN PRZR THAN 134 [404 adverse CNMT] level increases to greater than 13%

[40% adverse CNMT], THEN do Step 16.

16 Establish Normal Letdown: IF RCP seal return has been established, THEN establish excess

a. Establish charging line flow to letdown as follows:

REGEN Hx - GREATER THAN 20 GPM o Place excess letdown divert

b. Place the following switches to valve, AOV-312, to NORMAL.

CLOSE:

o Ensure CCW from excess letdown

~ Letdown orifice valves open, (AOV-745).

(AOV-200A, AOV-200B, and AOV-202) o Open excess letdown isolation

~ AOV-371, letdown isolation valve AOV-310.

valve

~ AOV-427, loop B cold leg to o Slowly open HCV-123 to maintain REGEN Hx excess letdown temperature less than 195'F and pressure less

c. Place letdown controllers in than 100 psig.

MANUAL at 35% open o Adjust charging pump speed as

~ TCV-130 necessary.

~ PCV-135 IF RCP seal return NOT established,

d. Reset both trains of XY relays THEN consult Plant Staff to for AOV-371 and AOV-427 determine if excess letdown should be placed in service.
e. Open AOV-371 and AOV-427
f. Open letdown orifice valves as necessary
g. Place TCV-130 in AUTO at 105'F
h. Place PCV-135 in AUTO at 250 psig
i. Adjust charging. pump speed and HCV-142 as necessary to control PRZR level

M W

EOP:

REV: 8 ES-1 1 SI TERMINATION PAGE 14 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check VCT Makeup System:

a. BAST levels - ANY GREATER THAN 5% a. Go to Step 18.
b. Check Annunciator B-23, BORIC b. Perform the following:

ACID TANK LO LO LEVEL-EXTINGUISHED 1) Adjust boric acid flow control valve to required

'flow from table.

BAST BORIC ACID LEVEL FLOW (GPM)

<10'0-15%

4.5 6.7 15-20$ 8.9

>20% 10.0

2) Go to Step 17d.
c. Adjust boric acid flow control valve in AUTO to 4.5 gpm
d. Verify the following: d. Adjust controls as necessary.

'h

1) RMW mode selector switch in AUTO
2) RMW control armed - RED LIGHT LIT
e. Check VCT level: e. Manually increase VCT makeup flow as follows:

o Level - GREATER THAN 20%

1) Ensure BA transfer pumps and

-OR- RMW pumps running. IF NOT, THEN dispatch AO to locally o Level - STABLE OR INCREASING reset MCC C and MCC D UV lockouts as necessary.

A v *

2) Place RMW flow control valve HCV-ill in MANUAL and increase RMW flow.
3) Increase boric acid flow as necessary.

I EOP I TITLE:

REV: 8 ES-1.1 SI TERMINATION PAGE 15 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Check Charging Pump Suction Aligned To VCT:

a. VCT level - GREATER THAN 20% a. IF VCT level can NOT be maintained greater than 5$ , THEN perform the following:
1) Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed
2) Continue with Step 19. WHEN VCT level greater than 40%,

THEN do Step 18b,

b. Verify charging pumps aligned to b. Manually align valves as VCT necessary.

o LCV-112C - OPEN o LCV-112B - CLOSED 19 Check RCS Hot Leg Control steam dump and total feed Temperatures - STABLE flow as necessary to stabilize RCS temperature.

i REV: 8

,ES-1 1 SI TERMINATION PAGE 16 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o WHEN using a PRZR PORV, THEN select one with an operable block valve.

o If auxiliary spray is in use, spray flow may be increased by AOV-294 and normal PRZR spray valves.

closing normal charging valve 20 Control PRZR Heaters And IF normal spray NOT available and Operate Normal Spray To letdown is in service, THEN perform Stabilize RCS Pressure the following:

a. Verify spray line fluid to PRZR AT less than 320'F. 'IF NOT, THEN control pressure using one PRZR PORV and go to Step 21.
b. Control pressure using auxiliary spray.

IF auxiliary spray NOT available, THEN use one PRZR PORV.

CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).

NOTE: TDAFW pump flow control valves fail open on loss of IA.

  • 21 Monitor.-Intact S/G Levels:

a, Narrow range level - GREATER a. Maintain total feed flow greater THAN'%'25% adverse CNMT] than 200 gpm until narrow range level greater than 5% [25%

adverse CNMT] in at least one S/G.

b. Control feed flow to maintain b. IF narrow range level in any S/G narrow range level between 17% continues to increase, THEN stop

[25% adverse CNMT] and 50% feed flow to that S/G.

EOP:

REV: 8 ES-1 ' SI TERMINATION PAGE 17 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: SW should be aligned-to CCW Hxs before restoring RCP seal cooling.

22 Check RCP Cooling: Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).

a. Check CCW to RCPs:

o Annunciator A-7, RCP lA CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED

b. Check RCP seal injection:

o Labyrinth seal D/Ps - GREATER THAN 15 INCHES WATER

-OR-o RCP seal injection flow to each RCP - GREATER THAN 6 GPM

EOPs REV: 8 ES-1 ' SI TERMINATION PAGE 18 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 23 Check If Seal Return Flow.

Should Be Established:

a. Verify RCP ¹1 seal outlet a. Go to Step 24.

temperature - LESS THAN 235'F

b. Verify RCP seal outlet valves b. Manually open valves as OPEN necessary.

~ AOV-270A

~ AOV-270B

c. Reset both trains of XY relays for RCP seal return isolation valve MOV-313
d. Open RCP seal return isolation d."Perform the following:

valve MOV-313

1) Place MOV-313 switch to OPEN.
2) Dispatch AO with key to RWST gate to locally open MOV-313.
e. Verify RCP ¹1 seal leakoff flow e. IF any RCP seal leakoff flow LESS THAN 5.5 GPM greater than 5.5 gpm THEN:

o Close the affected RCP seal discharge valve.

~ RCP A, AOV-270A

~ RCP"B, AOV-270B o Trip the affected RCP.

IF both RCP seal discharge valves are shut, THEN go to Step 24.

'.

f. Verify RCP ¹1 seal leakoff flow Refer to AP-RCP.1, RCP SEAL GREATER THAN,0.25 GPM MALFUNCTION.

EN>I TITLE:

REV: 8 ES-1. 1 SI TERMINATION PAGE 19 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 24 Verify All AC Busses Perform the following:

ENERGIZED BY OFFSITE POWER

a. IF any AC emergency bus normal o Normal feed breakers to all 480 feed'breaker open, THEN ensure volt busses - CLOSED associated D/G breaker closed.

o 480 volt bus voltage - GREATER b. Perform the following as THAN 420 VOLTS necessary:

o Emergency D/G output breakers- 1) Close non-safeguards bus tie OPEN- breakers:

~ Bus 13 to Bus 14 tie

~ Bus 15 to Bus 16 tie

2) Reset Bus 13 and Bus 15 lighting breakers.
3) Dispatch AO to locally reset and start two IA compressors,
4) Place the following pumps in PULL STOP:

~ EH pumps

~ Turning gear oil pump

~ HP seal oil backup pump

5) Restore power to MCCs:

~ A from Bus 13

~ B from Bus 15

~ E from Bus 15

~ F from Bus 15

6) Start CNMT RECIRC fans as necessary.
7) Refer to Attachment SI/UV for other equipment lost with loss of offsite power.
c. Try to restore offsite power to all AC busses (Refer to ER-ELEC.l> RESTORATION OF OFFSITE POWER).

EOP$ TLTLE$

REV: 8 ES-1. 1 SI TERMINATION PAGE 20 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.

25 Check If Source Range Channels Should Be Energized:

a. Source range channels- a. Go.to Step 25e.

DEENERGIZED

b. Check intermediate range flux- b. Perform the following:

EITHER CHANNEL LESS THAN 10 10 AMPS 1) IF neither intermediate range channel is decreasing, THEN initiate boration.

2) Continue with Step 26. WHEN flux is LESS THAN 10-10 ~ps on any operable channel, THEN do Steps 25c, d and e.
c. Check the following: c. Continue with step. 26. WHEN either condition met, THEN do o Both intermediate range Steps 25d and e.

channels - LESS THAN 10 AMPS

-OR-o Greater than 20 minutes since reactor trip

d. Verify source range detectors- d. Manually energize source range ENERGIZED detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).

IF source ranges can NOT be restored, THEN refer to ER-NIS.l, SR MAR'tJNCTION, and go to Step 26.

e. Transfer Rk-45 recorder to one source range and one intermediate range channel

V EOP:

REV 8 ES-1.1 SI TERMINATION PAGE 21 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 26 Check If Emergency Should Be Stopped:

D/Gs

a. Verify AC emergency busses a. Try to restore offsite power energized by offsite power: (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).

o Emergency D/G output breakers OPEN o AC emergency bus voltage-GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers - CLOSED

b. Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)

II k

I

EOP: TITLE:

REV: 8 ES-1.1 SI TERMINATION PAGE 22 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

CAUTION IF RCP SEAL COOLING HAD PREVIOUSLY BEEN LOST> THEN THE AFFECTED RCP SHOULD NOT BE STARTED PRIOR TO A STATUS EVALUATION.

27 Check RCP Status AT LEAST Perform the following:

ONE RUNNING

a. Establish conditions for starting an RCP; o . Verify bus 11A or 11B energized.

o Refer to Attachment RCP START.

b. Start one RCP.

IF an RCP can NOT be started, THEN verify natural circulation (Refer to Attachment NC).

IF natural circulation NOT verified, THEN increase dumping steam from intact S/Gs.

'I Na

EOP: TITLE:

REV' ES-1.1 SI TERMINATION PAGE 23 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 28 Establish Normal Shutdown Alignment:

a. Check condenser - AVAILABLE a. Dispatch AO to perform Attachment SD-2.
b. Perform the following:

o Open generator disconnects

~ 1G13A71

~ 9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o "

Rotate reheater steam supply controller cam to close valves o Place reheater dump valve switches to HAND o Stop all but one condensate pump

c. Verify adequate Rx head cooling:')

Check IA to CNMT - AVAILABLE 1) Go to Step 29.

2) Verify at least one control 2) Manually start one fan as rod shroud fan - RUWING power supply permits (45 kw)
3) Verify one Rx compartment 3) Perform the following:

~

cooling fan - RUNNING o Dispatch AO to reset UV relays at MCC C and MCC D.

o Manually start one fan as power supply permits (23 kw)

d. Verify Attachment SD COMPLETE

EOP:

REV: 8 ES-1.1 SI TERMINATION PAGE 24 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 29 Maintain Plant Conditions Stable:

a. RCS pressure - BETWEEN 1800 PSIG a. Control PRZR heaters and spray AND 2235 PSIG as necessary.
b. PRZR level - BETWEEN 20% AND 30$ b. Control charging as necessary.
c. Intact S/G narrow range levels- c. Control S/G feed flow as BETWEEN 17% AND 39% necessary.
d. RCS cold leg temperature - STABLE d. Control dumping steam as necessary. IF cooldown continues, THEN close both MSIVs.
  • 30 Monitor SI Reinitiation Criteria:.
a. RCS subcooling based on core a. Manually operate SI pumps as exit T/Cs - GREATER THAN O' necessary and go to E-l, LOSS OF USING FIGURE MIN SUBCOOLING REACTOR OR SECONDARY COOLANT, Step l.
b. PRZR level - GREATER THAN 5% b. Control charging flow to

[30% adverse CNMT] maintain PRZR level.

IF PRZR level can NOT be maintained, THEN manually operate SI pumps as necessary and go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step l.

EOP! T1TLE:

REV: 8 ES-1 1 SI TERMINATION PAGE 25 of 25 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT'OBTAINED 31 Go To Procedure 0-2.1, NORMAL SHUTDOWN TO HOT SHUTDOWN

-END-

EOPs TjTLE:

REV: 8 ES-1 1 SI TERMINATION PAGE 1 of 1 ES-1.1 APPENDIX LIST'ITLE PAGES

1) RED PATH

SUMMARY

2) FIGURE MIN SUBCOOLING
3) ATTACHMENT CNMT RECIRC
4) ATTACHMENT D/G STOP
5) ATTACHMENT NC
6) ATTACHMENT SEAL COOLING
7) ATTACHMENT RCP START
8) ATTACHMENT SD-1
9) ATTACHMENT SD-2
10) ATTACHMENT SI/UV
11) ATTACHMENT SI FLUSH
12) ATTACHMENT AUX BLDG SW
13) FOLDOUT

TITLE%

REV: 8 ES-1. 1 SI TERMINATION PAGE 1 of 1 RED PATH

SUMMARY

a. SUBCRITICALITY - Nuclear power greater than 54
b. CORE COOLING - Core exit T/Cs greater than 1200'F

-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs) less than 434 [46%

adverse CNMT]

c. HEAT SINK - Narrow range level in all S/Gs less than 54

[254 adverse CNMT] AND total feedwater flow less than 200 gpm

d. .INTEGRITY Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F
e. CONTAINMENT - CNMT pressure greater than 60 psig

EOPt T!TLE:

REV: 8 ES-F 1 SI TERMINATION PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin = Saturation Temperature From Figure Below [-] Core Exit T/C Indication RC S PRESSURE (PSIG) 2500 2400 RCS PRESSURE 2300 INCREMENTS 20 PSIG 2200 2100 2000 1900 1800 1700 1600 1500 1400 SUBCOOLED 1300 REGION 1200 1100 1000 900 800 INADEQUATE 700 SUBCOOLING 600 REGION ADVERSE CNH 500 400 300 200 NORMAL CNHT TEMPERATURE INCREMENTS 10'F 100 0

200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEHPERATURE ('F)

EOP: TlTLEi REV: 8 ES-1.1 SI TERMINATION PAGE 1 of 1 FOLDOUT PAGE 1~ SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN manually operate SI pumps as necessary and go to E-1, LOSS OF REACTOR OR SECONDARY COOLANT, Step 1:

o RCS subcooling based on core exit T/Cs LESS THAN O'F USING FIGURE MXN SUBCOOLING OR-o PRZR level CHARGING CAN NOT CONTROL LEVEL GREATER THAN 5%

[304 adverse CNMT]

2. SI TERMINATION CRITERIA IF ALL conditions listed below occur, THEN go, to ES-1.1, SI TERMINATION, Step 1:
a. RCS subcooling based on core exit T/Cs GREATER THAN O'F USING REQUIREMENTS OF FIGURE MIN SUBCOOLING
b. Total feed flow to intact S/Gs GREATER THAN 200 GPM OR Narrow range level in at least

-

one intact S/G - GREATER THAN 54 [254 adverse CNMT]

c. RCS pressure:

o GREATER THAN 1625 PSIG [1825 psig adverse CNMT]

o STABLE OR INCREASING

d. PRZR level GREATER THAN 54 [30% adverse CNMT]

3 ~ SECONDARY INTEGRITY CRITERIA IF any S/G pressure is decreasing in an uncontrolled manner or is completely depressurized AND has not been isolated, THEN go to E-2, FAULTED S/G ISOLATXON, Step 1.

4. COL " G RECIRCULATION SWITCHOVER CRITERION IF RWQT level decreases to less than 284, THEN go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step 1.
5. AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS) .

6 ~ E-3 TRANSITION CRITERIA IF any S/G level increases in an uncontrolled manner or any S/G has abnormal radiation, THEN go to E-3, STEAM GENERATOR TUBE RUPTURE, Step 1.

il 4