{{#Wiki_filter:U.S NUCLEAR REGULATORY COMMISSION 44 1 REQUIRED TO OPEN LOWER ICE CONDENSER INLET ODOR 3-R EXCEEDED THE LIMIT IDENTIFIED NRC FORM 366 (7.77)LICENSEE EVENT REPORT 0 CONTROL BLOCK: 1, (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6~01 M I D C C I Q2 0 0 0 0 0 0 0 0 0 0 0 Qs 4 I I 1 I Q4~Qs 7 8 9 LICENSEE'ODE 14'IS LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T r LJiQ8"0 0 0 3 I 5Q7 0 4 1 0 7 BQ80 9 7 9 Q DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES
{{#Wiki_filter:}}
&10 I'IHILE PERFORMING A ROUTINE SURVEILLATICE TEST IT IIAS DISCOVERED THAT THE TORQUE UNDER T.S.3.6.5.3.~08~08~07~08 7 8 9 SYSTEM CAUSE CAUSE COMP VALVE 80~OB 7 8 CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE~SB Q>>~BQ2~A Qs Z Z Z Z Z Z Q14~Z Q1s~Z Q18 9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION 21 22 23 24 26 27 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRDQ PRIME COMP.COMPONENT TA/EN ACTIN ON PJ,ANT MET1IOD/OUI++22 SUBIIIJTTED FORM SUB.SUPPLIER MANUFACTURER LJQ18 LJQ" L'JQ20~Q21"" UQ23 LJNQ24 DNQ28 W I 3 0 Q28 33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS&27 THE SHEET METAL SCREWS LOCATED-ACING THE BOTTOM"OF THE DOOR WERE DISCOVERED TO Bf RUBBING AGAINST THE SURFACE AT THE EDGE OF THE DOOR FRAME REQUIRING EXCESSIVE FORCE TO OPEN THE DOOR.THE DOOR FRAME EDGE WAS DEPRESSED TO ALLOW PROPER CLEARANCE AND METHOD OF DISCOVERY DISCOVERY DESCRIPTION Q32~BQ31 SURVEILLANCE TEST 45 46 LOCATION OF RELEASE Q 45 A RETEST WAS PERFORMED WITH SATISFACTORY RESULTS.1 3 SEE SUPPLEMENT.
~14 7 8 4 FACILITY STATUS 56 POWER OTHER STATUS QBO s~HQ2s~<<0 Q28 NA 8 9 10 12 13 44 ACTIVITY CONTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY Q6 6~Z Q33 Z Q34 NA.NA 7 8 9'0 44 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION
~~~~47~00 0 Q Z Q38 NA 7 8 9 11 12 13 PERSONNEL INJURIES 80 80 80 80 7 8 7 8 o 7 8 NAME OF PREPARER T.P.Beilman 9 11 12 LOSS OF OR DAMAGE TO FACILITY Q43 TYPE DESCRIPTION ZQ4, NA 9 10 PUBLICITY ISSUED DESCRIPTION
~L~JQ44 NA 9 10 80.80 NRC USE ONLY 80 48 0 Q 68 69 616-465-5901 778mw~ggv~
SUPPLEMENT TO LER 879-028 03L-0 SUPPLEMENT TO CAUSE DESCRITPION FOLLOWING AN INSPECTION OF THE REMAINING ICE CONDENSER DOORS FOR SIMILAR PROBLEMS, A DESIGN CHANGE WAS SUBMITTED TO CHANGE THE POSITIONING OF THE LOWER INLET DOOR FRAMES TO ALLOW A GREATER CLEARANCE BETWEEN THE DOOR AND FRAME.}}

Revision as of 05:03, 24 October 2019

LER 79-028/03L-0 on 790410:torque Required to Open Lower Ice Condenser Inlet Door 3-R Exceeded Tech Specs.Caused by Sheet Metal Screws Loose at Bottom of Door.Door Frame Edge Depressed
ML17317B187
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 05/09/1979
From: Beilman T
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17317B184 List:
References
LER-79-028-03L, LER-79-28-3L, NUDOCS 7905150441