ML17335A358: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:ATTACHMENT 2A TO AEP:NRC: 09000 TECHNICAL SPECIFICATIONS PAGES MARKED TO SHOW PROPOSED CHANGES REVISED PAGES UNIT 1 3/4 6-27 B 3/4 6-4'P8i208004b 98i203 PDR 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6 CONTAINMENT SYSTEMS SURVEILLANCE RE UIREMENTS Continued 4 tD'a E O'o stg Cd)C4 O Q CJ 4 C5 O O O o~gy O crt cl stg gO~O~rn Ctg sts~Q~sty O BBca 3.4 8g W4 E 0 g ig Qt shall be constituted of one basket each from Radial Rows I, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing)within each bay.If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall bc weighed.The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less, than 1333 pounds/basket at a 95%level of confidence.
{{#Wiki_filter:ATTACHMENT 2A TO AEP:NRC: 09000 TECHNICAL SPECIFICATIONS PAGES MARKED TO SHOW PROPOSED CHANGES REVISED PAGES UNIT 1 3/4 6-27 B 3/4 6-4
The icc condenser shall also be subdivided into 3 groups of baskets, as follows: Group 1-bays I through 8, Group 2-bays 9 through 16, and Group 3-bays 17 through 24.The minimum average ice weight of the sample baskets from Radial Rows I, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95%level of confidence.
'P8i208004b 98i203 PDR
The minimum total ice condenser icc weight at a 95%level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not bc less than 2,590,000 pounds.+g Verifying, by a visual inspection of at ieastinve fioutAptutsegee per ice condenser bay, that the accumulation of frost or ice on flow between ice baskets and past lattice rames is restrict to a nommal thickness of 3/8 inches.If one fiow+ssage-per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional flo rom the same++bay shall be visually inspected.
If these additional flow I aesages are found acceptable, thc surveillance program may proceed considering the singl'c deficiency as unique and acceptable.
More than one restricted flow paseeggg per bay is evidence of abnormal degradation At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage.The ice baskets shall be raised at least 12 feet for this inspection.
At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support str'uctures
~tunung vane's restricted to a nominal thickness of 3/8 inches.An accumulation of frost or ice greater than this thickness is evidence of abnormal degradation of the ice condenser.
and will require a 100%inspection of that bay to determine, by calculation, that thc total flow passage blockage is less than the 15%assumed in the analysis of lower subcompartment pressurization following a, LOCA or MSLB.Gys&rs wK/4 4 ghw~~a/~COOK NUCLEAR PLANT-UNIT 1 Page 3/4 6-27 AMENDMENT 408, AQUA, 438, 444, 220 3/4 BASES 3/4.6 CONTAINMENT SYSTEMS'3/4.6.5'ICE CON DENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than l2 psig during LOCA conditions.
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will I)be distributed evenly through the containment bays, 2)contain sufficient boron to preclude dilution of the containinent sump following the LOCA and 3)contain sufficient heat removal capability to condense the reactor system volume released during a LOCA.These conditions are consistent with the assumptions used in the accident analyses.The minimum weight figure of 1333 pounds of ice per basket contains a 5%conservative allowance for ice loss through sublimation.
In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward.In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature.
In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.COOK NUCLEAR PLANT-UNIT I Page B 3/4&4 AMENDMENT 480, 220


INSERT FOR PAGE B 3/4 6-4 (Unit 1)\The containment sub-compartment analyses assumes a 15%blockage throughout the ice condenser flow paths.The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations.
3/4      LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6   CONTAINMENTSYSTEMS SURVEILLANCE RE UIREMENTS Continued shall be constituted of one basket each from Radial Rows I, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets O                    from the same bay shall bc weighed. The minimum average weight of ice from o ~gy                    the 20 additional baskets and the discrepant basket shall not be less, than 1333 pounds/basket at a 95% level of confidence.
This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances.
O crt cl  stg                The icc condenser shall also be subdivided into 3 groups of baskets, as follows:
In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay.Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively.
                  ~O gO
There are a total of 81 flow channels in each bay-one per ice basket.The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.The 3/8" frost or ice accumulation in a flow channel criterion provides only an indicator of ice condenser condition.
                      ~                    Group 1 - bays I through 8, Group 2 - bays 9 through 16, and Group 3 - bays rn Ctg 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows I, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.
The lattice frame thickness is 3/8", and therefore, this dimension provides a convenient visual reference during flow channel inspections.
sts The minimum total ice condenser icc weight at a 95% level of confidence shall be calculated using all ice basket weights determined during this weighing
Frost or ice buildup in excess of 3/8" shall be evaluated by selecting a further representative sample of 20 flow channels that spiral outward from the affected flow channel.This sample population assures that the areas around and adjacent to the blocked channel are also inspected.
                  ~Q~O sty program and shall not bc less than 2,590,000 pounds.
More than one restricted flow channel per bay requires a 100%inspection of the bay and calculation to ensure that the 15%blockage limit is met.Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition.
                                                                                                        +g 4tD BBca          3.        Verifying, by a visual inspection of at ieastinve fioutAptutsegee per ice condenser 4 8g                      bay, that the accumulation of frost or ice on
The 3/8" thickness criterion provides a threshold to provide reasonable assurance that any frost or ice buildup is corrected well before the 15%blockage assumption is approached in these areas.
'a                 W4                                                    flow           between ice baskets and past lattice 0 g E E                ig    Qt                    rames is restrict  to a nommal thickness of 3/8 inches. If one fiow+ssage-per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional flo                rom the same ++
ATTACHMENT 2B TO AEP:NRC:09000 TECHNICAL SPECIFICATIONS PAGES MARKED TO SHOW PROPOSED CHANGES REVISED PAGES UNIT 2
bay shall be visually inspected. If these additional flow I aesages are found O                                          acceptable, thc surveillance program may proceed considering the singl'c
'o stg deficiency as unique and acceptable. More than one restricted flow paseeggg per Cd)                                        bay is evidence  of abnormal degradation C4 O
Q At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support str'uctures tunung vane 's restricted to a nominal thickness of 3/8 inches. An accumulation of frost
                                                                                                                            ~
CJ                              or ice greater than this thickness is evidence of abnormal degradation of the ice 4C5 condenser.
O At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice O                                baskets are free of detrimental structural wear, cracks, corrosion or other damage. The ice baskets shall be raised at least 12 feet for this inspection.
and will require a 100% inspection of that bay to determine, by calculation, that thc total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a, LOCA or MSLB.
Gys& rs wK/
4 4 ghw~~a/~
COOK NUCLEAR PLANT-UNIT 1                              Page 3/4 6-27        AMENDMENT408,            AQUA, 438, 444, 220


3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6 CONTAINMENT SYSTEMS SURVEILLANCE RE UlREMENTS Continued 4'O tD C O'O Ctg CO C O O O'a O O O O Ctg O O jly Vl OQ~Cto CO~cn Ctg cn tn O ty P.C c, shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing)within each bay.If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed.The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/ba'sket at a 95%level of confidence.
3/4       BASES 3/4.6     CONTAINMENTSYSTEMS
The ice condenser shall also be subdivided into 3 groups of baskets, as follows: Group 1-bays 1 through 8, Group 2-bays 9 through 16, and Group 3-bays 17 through 24.The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95%level of confidence.
'3/4.6.5 'ICE CON DENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than l2 psig during LOCA conditions.
3.The minimum total ice condenser ice weight at a 95%level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.Verifying, by a visual inspection of at teastjttwe tlowgpassegee per ice condenser bay, that the accumulation of frost or ice on flow between ice baskets and past lattice rames is restrict to a noaunal ickness of 3/8 mches.If one flowjgssage-per bay is found to have an accumulation of.frost or ice greater than this thickness, a representative sample of 20 additional flo rom the same bay shal be visu~ly inspect~.If these addition~flow~mme are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable.
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will I) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containinent sump following the LOCA and
More than one restricted flow passage per bay is evidence of abnormal degradation At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage.The ice baskets shall be raised at least 12 feet for this inspection.
: 3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.
At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support stiuctures andg turnmg van's restricted to a nominal thickness of 3/8 inches.An accumulation of frost or ice greater than this thickness is evidence of abnormal degradation of the ice condenser.
The minimum weight figure of 1333 pounds of ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.
and will require a 100%inspection of that bay to determine, by calculation, that the total flow passage blockage is less than the 15%assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.vV&tlap nate,/Q 4 4Cj~nna/X COOK NUCLEAR PLANT-UNIT 2 Page 3/4 6-36 AMENDMENT QO, 42$, 204 3/4 BASES 3/4.6 CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL'L~The OPERABILITY of the equipment and systems required for the detection and control of hydrogen gas ensures that this equipment will be available to maintain the hydrogen concentration within containment below its flammable limit during post-LOCA conditions.
3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.
Either recombiner unit is capable of controlling the expected hydrogen generation associated with: I)'zirconium-water reactions; 2)radiolytic decomposition of water;and 3)corrosion of metals within containment.
COOK NUCLEAR PLANT-UNIT I                            Page B 3/4  &4                        AMENDMENT480, 220
These hydrogen control systems are consistent with the recommendations of Regulatory Guide 1.7,"Control of Combustible Gas Concentrations in Containment Following a LOCA," March 1971.The acceptance criterion of 10,000 ohms is based on the test being performed with the heater element at an ambient temperature, but can be conservatively applied when the heater element is at a temperature above ambient.3/4.6.5 ICE CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak prcssure transient to less than 12 psig during LOCA conditions.
 
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will I)be distributed evenly through the containment bays, 2)contain sufficient boron to preclude dilution of the containment sump following the LOCA and 3)contain sufficient heat removal capability to condense the reactor system volume released during a LOCA.These conditions are consistent with the assumptions used in the accident analyses.The minimum weight figure of 1333 pounds of, ice per basket contains a 5%conservative allowance for ice loss through sublimation.
\
In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward.In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature.
INSERT FOR PAGE B    3/4 6-4 (Unit 1)
In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.COOK NUCLEAR PLANT-UNIT 2 Page B 3/4 64 AMENDMENT 4, 444, 104, 207 INSERT FOR PAGE B 3/4 6-4 (Unit 2)l The containment sub-compartment analyses assumes a 15%blockage throughout the ice condenser flow paths.The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations.
The containment    sub-compartment analyses assumes a 15% blockage throughout    the   ice condenser flow paths.       The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the flow area left between the crane wall and the containment wall inside surfaces,            after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances.         In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay. Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively. There are a total of 81 flow channels in each bay  one per ice basket.
This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that ele'vation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances.
The  selection of one flow channel each from radial rows 1 and 9 assures  that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.
In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay.Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively.
The 3/8" frost or ice accumulation in a flow channel criterion provides only an indicator of ice condenser condition.            The lattice frame thickness is 3/8", and therefore, this dimension provides a convenient visual reference during flow channel inspections.     Frost or ice buildup in excess of 3/8" shall be evaluated by selecting a further representative sample of 20 flow channels that spiral outward from the affected flow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100% inspection of the bay and calculation to ensure that the 15% blockage limit is met.
There are a total of 81 flow channels in each bay-one per ice basket.The selection of one flow channel each, from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.The 3/8" frost or ice accumulation in a flow channel criterion provides only an indicator of ice condenser condition.
Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support              elevations,  the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to provide reasonable assurance that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.
The lattice frame thickness is 3/8", and therefore, this dimension provides a convenient visual reference during flow channel inspections.
 
Frost or ice buildup in excess of 3/8" shall be evaluated further by selecting a further representative sample of 20 flow channels that spiral outward from the affected flow channel.This sample population assures that the areas around and adjacent to the blocked channel are also inspected.
ATTACHMENT 2B TO AEP:NRC:09000 TECHNICAL SPECIFICATIONS PAGES MARKED TO SHOW PROPOSED CHANGES REVISED PAGES UNIT 2
More than one restricted flow channel per bay requires a 100%inspection of the bay and calculation to ensure that the 15%blockage limit is met.Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations,.the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition.
 
The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15%blockage assumption is approached in these areas.
3/4      LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6     CONTAINMENTSYSTEMS SURVEILLANCE RE UlREMENTS Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets O                  from the same bay shall be weighed. The minimum average weight of ice from Ctg O jlyO                  the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/ba'sket at a 95% level of confidence.
ATTACHMENT 3A TO AEP:NRC: 09000 PROPOSED TECHNICAL SPECIFICATIONS PAGES REVISED PAGES UNIT 1 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIRIMENTS 3/4.6 CONTAINMENT SYSTEMS Surveillance.Re uirements Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing)within each bay.If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed.The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/basket at a 95%level of confidence.
Vl The ice condenser shall also be subdivided into 3 groups of baskets, as follows:
The ice condenser shall also be subdivided into 3 groups of baskets, as follows: Group 1-bays 1 through 8, Group 2-bays 9 through 16, and Group 3-bays 17 through 24.The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95%level of confidence.
                    ~OQ  Cto Group 1- bays 1 through 8, Group 2- bays 9 through 16, and Group 3- bays CO
The minimum total ice condenser ice weight at a 95%level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.Verifying, by a visual inspection of at least four flow channels per ice condenser bay, that the accumulation of frost or ice on flow channels between ice baskets and past lattice frames is restricted to a nominal thickness of 3/8 inches.Flow channels will be selected as follows: two at random from radial rows 2 through 8 and one each from radial rows 1 and 9.If one flow channel per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional flow channels from the same bay shall be visually inspected.
                        ~
If these additional flow channels are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable.
cn Ctg 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.
More than one restricted flow channel per bay is evidence of abnormal degradation and will require a 100%inspection of that bay to determine, by calculation, that the total flow passage blockage is less than the 15%assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower inlet plenum support structures and taming canes, on the top deck floor grating and on the intermediate deck, is rmtricted to a nominal thickness of 3/8 inches.An accumulation of frost and ice greater than this thickness is evidence of abnormal degradation of the ice condenser.
cn tn The minimum total ice condenser ice weight at a 95% level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.
At least once per 40 months by lifting arid visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage.The ice baskets shall be raised at least 12 feet for this inspection.
4                                  3.        Verifying, by a visual inspection of at teastjttwe tlowgpassegee per ice condenser bay, that the accumulation of frost or ice on
COOK NUCLEAR PLANT-UNIT 1 Page 3/4 6-27 AMENDMENT 408, 4Skp 488, 444p 220 l W4 4 A I's Il 3/4 BASES 3/4,6 CONTAINMENT SYSTEMS 3/4,6.5 ICE.CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than 12 psig during LOCA conditions.
'O                                                                        flow            between ice baskets and past lattice O
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will 1)be distributed evenly through the containment bays, 2)contain sufficient boron to preclude dilution of the containment sump following the LOCA and 3)contain sufficient heat removal capability to condense the reactor system volume released during a LOCA.These conditions are consistent with the assumptions used in the accident analyses.The minimum weight figure of 1333 pounds of ice per basket contains a 5%conservative allowance for ice loss through sublimation.
ty P. C rames is restrict  to a noaunal ickness of 3/8 mches. If one flowjgssage-per bay is found to have an accumulation of. frost or ice greater than this tD                                          thickness, a representative sample of 20 additional flo              rom the same bay shal be visu~ly inspect~. If these addition~ flow ~mme              are found C
In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward.In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.The containment sub-compartment analysis assumes a 15%blockage throughout the ice condenser flow paths.The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations.
O                                          acceptable, the surveillance program may proceed considering the single
This includes the fiow area left between the crane wall and the coritainment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances.
'O Ctg deficiency as unique and acceptable. More than one restricted flow passage per CO                                          bay is evidence of abnormal degradation C
In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total fiow area in the bay.Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively.
c,    At least once per    18 months by verifying, by a visual inspection, of each ice condenser O                                bay, that the accumulation of frost or ice on the lower plenum support stiuctures andg O
There are a total of 81 flow channels in each bay-one per ice basket.The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.The 3/8" criterion for frost or ice accumulation in a flow channel provides only an indicator of ice condenser condition.
turnmg van 's restricted to a nominal thickness of 3/8 inches. An accumulation of frost O                                or ice greater than this thickness is evidence of abnormal degradation of the ice
The lattice frame thickness is 3/8" and, therefore, this dimension provides a convenient visual reference during flow channel inspections.
'a                                condenser.
Frost or ice build-up in excess of 3/8" shall be evaluated further by selecting a representative sample of 20 flow channels that spiral outward from the affected fiow channel.This sample population assures that the areas around and adjacent to the blocked channel are also inspected.
O O
More than one restricted flow channel per bay requires a 100%inspection of the bay and calculation to ensure that the 15%blockage limit is met.Because the minimum ice condenser fiow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vancs, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition.
At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice O                                baskets are free of detrimental structural wear, cracks, corrosion or other damage. The ice baskets shall be raised at least 12 feet for this inspection.
The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15%blockage assumption is approached in these areas.3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature.
nate,/
In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.COOK NUCLEAR PLANT-UNIT I Page B 3/4 64 AMENDMENT 480, RRO ATTACHMENT 3B TO AEP:NRC: 09000 PROPOSED TECHNICAL SPECIFICATIONS PAGES REVISED PAGES UNIT 2 4 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6 CONTAINMENT SYSTEMS SURVEILLANCE RE UIREMENTS Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing)within each bay.If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed.The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/basket at a 95%level of confidence.
and willrequire a 100% inspection of that bay to determine, by calculation, that the total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.
The ice condenser shall also be subdivided into 3 groups of baskets, as follows: Group 1-bays 1 through 8, Group 2-bays 9 through 16, and Group 3-bays 17 through 24.The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95%level of confidence.
vV &tlap Q 4 4Cj~nna/X COOK NUCLEAR PLANT-UNIT2                              Page 3/4 6-36                      AMENDMENTQO, 42$ , 204
The minimum total ice condenser ice weight at a 95%level of confidence shall be calculated using all ice'basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.Verifying, by a visual inspection of at least four flow channels per ice condenser bay, that the accumulation of frost or ice on flow channels between ice baskets and past lattice frames is restricted to a nominal thickness of 3/8 inches.Flow channels will be selected as follows: two at random from radial rows 2 through 8 and one each from radial rows 1 and 9.If one flow channel per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional fiow channels from the same bay shall be visually inspected.
 
If these additional flow channels are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable.
3/4      BASES 3/4.6    CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL
More than one restricted flow channel per bay is evidence of abnormal degradation and will require a 100%inspection of that bay to determine, by calculation,.that the total flow passage blockage is less than the 15%assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support structures and turning vanes, on the top deck floor grating and on the intermediate deck, is restricted to a nominal thickness of 3/8 inches.An accumulation of frost or ice greater than this thickness is evidence of abnormal degradation of the ice condenser.
  'L ~
At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage.The ice baskets shall be raised at least 12 feet for this inspection.
The OPERABILITY of the equipment and systems required for the detection and control of hydrogen gas ensures that this equipment will be available to maintain the hydrogen concentration within containment below its flammable limit during post-LOCA conditions. Either recombiner unit is capable of controlling the expected hydrogen generation associated with: I)'zirconium-water reactions; 2) radiolytic decomposition of water; and 3) corrosion of metals within containment. These hydrogen control systems are consistent with the recommendations of Regulatory Guide 1.7, "Control of Combustible Gas Concentrations in Containment Following a LOCA," March 1971.
COOK NUCLEAR PLANT-UNIT 2 Page 3/4 6-36 AMENDMENT 90, 485,%4 3/4 BASES 3/4.6 CONTAINMENT SYSTEMS 3/4:6.4 COMBUSTIBLE GAS CONTROL The OPERABILITY of the equipment and systems required for the detection and control of hydrogen gas ensures that this equipment will be available to maintain the hydrogen concentration within containment below its flammable limit during post-LOCA conditions.
The acceptance criterion of 10,000 ohms is based on the test being performed with the heater element at an ambient temperature, but can be conservatively applied when the heater element is at a temperature above ambient.
Either recombiner unit is capable of controlling the expected hydrogen generation associated with 1)zirconium-water reactions, 2)radiolytic decomposition of water and 3)corrosion of metals within containment.
3/4.6.5 ICE CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak prcssure transient to less than 12 psig during LOCA conditions.
These hydrogen control systems are consistent with the recommendations of Regulatory Guide 1.7,"Control of Combustible Gas Concentrations in Containment Following a LOCA," March 1971.3/4.6.5 ICE CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than 12 psig during LOCA conditions.
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will I) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containment sump following the LOCA and
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will 1)be distributed evenly through the containment bays, 2)contain sufficient boron to preclude dilution of the containment sump following the LOCA and 3)contain sufficient heat removal capability to condense the reactor system volume released during a LOCA.These conditions are consistent with the assumptions used in the accident analyses.The minimum weight figure of 1333 pounds of ice per basket contains a 5%conservative allowance for ice loss through sublimation.
: 3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.
In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward.In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.The containment sub~mpartmcnt analysis assumes a 15%blockage throughout the ice condenser flow paths.The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations.
The minimum weight figure of 1333 pounds of, ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.
This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances.
3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.
In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay.Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively.
COOK NUCLEAR PLANT-UNIT 2                           Page B 3/4  64                  AMENDMENT 4, 444, 104, 207
There are a total of 81 flow channels in each bay-one per ice basket.The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.The 3/8" criterion for frost or ice accumulation in a flow channel provides only an indicator of ice condenser condition.
 
The lattice frame thickness is 3/8" and, therefore, this dimension provides a convenient visual reference during flow channel inspections.
INSERT FOR PAGE B    3/4 6-4 (Unit 2) l The containment    sub-compartment analyses assumes a 15% blockage throughout    the  ice condenser flow paths.      The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the flow area left between the crane wall and the containment wall inside surfaces,          after subtracting out the areas for the ice condenser equipment at that ele'vation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances.         In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay. Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively. There are a total of 81 flow channels in each bay  one per ice basket.
Frost or ice build-up in excess of 3/8" shall be evaluated further by selecting a representative sample of 20 flow channels that spiral outward from the affected flow channel.This sample population assures that the areas around and adjacent to the blocked channel are also inspected.
The  selection of one flow channel each, from radial rows 1 and 9 assures  that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.
More than one restricted flow channel per bay requires a 100%inspection of the bay and calculation to ensure that the 15%blockage limit is met.COOK NUCLEAR PLANT-UNIT 2 Page B 3/4&4 AMENDMENT 4, 464, 204, 2%
The 3/8" frost or ice accumulation in a flow channel criterion provides only an indicator of ice condenser condition.            The lattice frame thickness is 3/8", and therefore, this dimension provides a convenient visual reference during flow channel inspections.      Frost or ice buildup in excess of 3/8" shall be evaluated further by selecting a further representative sample of 20 flow channels      that spiral outward from the affected flow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected.          More than one restricted flow channel per bay requires a 100%
~,~u u~'
inspection of the bay and calculation to ensure that the 15%
3/4 BASES 3/4,6 CONTAINMENT SYSTEMS Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition.
blockage  limit is  met.
The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15%blockage assumption is approached in these areas.3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature.
Because  the minimum ice condenser flow area in each ice condenser bay  occurs at the lattice frame support elevations,          . the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.
In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.COOK NUCLEAR PLANT-UNIT 2 Page B 3/4 6-5 AMENDMENT 4, 464, 204, 2%
 
~~
ATTACHMENT 3A TO AEP:NRC: 09000 PROPOSED TECHNICAL SPECIFICATIONS PAGES REVISED PAGES UNIT 1
ATTACHMENT 4 TO AEP:NRC:09000 EVALUATION OF SIGNIFICANT HAZARDS CONSIDERATION Attachment 4 TO AEP:NRC:09000 Page 1 Evaluation of Si nificant Hazards Consideration The Licensee has evaluated this proposed amendment and determined that it involves no significant hazards consideration.
 
According to 10 CFR 50.92(c), a proposed amendment to an operating license involves no significant hazards consideration, if operation of the facility in accordance with the proposed amendment should not: 1.involve a significant increase in the probability of occurrence or consequences of an accident previously evaluated; 2.create the possibility of a new or different kind of accident from any previously analyzed;or 3.involve a significant reduction in a margin of safety.The Licensee proposes to revise T/S 4.6.5.1b.3 and 4.6.5.1c,"Ice Condenser, Ice Bed," and its associated bases for units 1 and 2.The proposed changes would revise the surveillance for ice condenser flow channels to provide reasonable assurance that blockage of flow channels is detected and evaluated to the maximum analyzed blockage of 15%.The bases are revised to reflect the changes to the T/S and to clarify the intent of additional representative sampling when blocked channels are detected.The determination that'the criteria set forth in 10 CFR 50.92 are met for this amendment request is indicated below.1.Does the change involve a significant increase in the probability or consequences of an accident previously evaluated?
3/4      LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCEREQUIRIMENTS 3/4.6     CONTAINMENTSYSTEMS Surveillance.Re uirements Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed. The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/basket at a 95% level of confidence.
The ice condenser system is used to mitigate the consequences of an accident and has no impact on the initiation of any evaluated accidents.
The ice condenser shall also be subdivided into 3 groups of baskets, as follows:
Therefore, changing the flow channel surveillance does not increase the probability of an evaluated accident.The proposed changes to the flow channel surveillance provide additional assurance beyond current requirements to provide reasonable assurance that the maximum analyzed blockage of 15%is not exceeded.Therefore, the change does not represent an increase in the consequences of an accident previously evaluated.
Group 1- bays 1 through 8, Group 2- bays 9 through 16, and Group 3- bays 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.
2.Does the change create the possibility of a new or different kind of accident from any accident previously evaluated?
The minimum total ice condenser ice weight at a 95% level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.
The proposed changes do not create the possibility of a new or different kind of accident from any accident previously evaluated.
Verifying, by a visual inspection of at least four flow channels per ice condenser bay, that the accumulation of frost or ice on flow channels between ice baskets and past lattice frames is restricted to a nominal thickness of 3/8 inches. Flow channels will be selected as follows: two at random from radial rows 2 through 8 and one each from radial rows 1 and 9. If one flow channel per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional flow channels from the same bay shall be visually inspected. If these additional flow channels are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable. More than one restricted flow channel per bay is evidence of abnormal degradation and will require a 100% inspection of that bay to determine, by calculation, that the total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.
The ice condenser has no function during normal operation.
At least once per    18 months by verifying, by a visual inspection, of each ice condenser bay,  that the accumulation  of frost or ice on the lower inlet plenum support structures and taming canes, on the top deck floor grating and on the intermediate deck, is rmtricted to a nominal thickness of 3/8 inches. An accumulation of frost and ice greater than this thickness is evidence of abnormal degradation of the ice condenser.
It is a passive system that functions after an Attachment 4 TO AEP:NRC:09000 Page 2 accident has already occurred.The proposed change to the ice condenser flow channel surveillance does not alter physical characteristics of the ice condenser, nor does it change the function of the ice condenser.
At least once per 40 months by lifting arid visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage.             The ice baskets shall be raised at least 12 feet for this inspection.
No new failure mechanisms are introduced by this change.Therefore, it was concluded that the proposed changes do not create the possibility of a new or different kind of accident from any previously evaluated.
COOK NUCLEAR PLANT-UNIT1                              Page 3/4 6-27            AMENDMENT408,        4Skp 488, 444p 220
3.Does the change involve a significant reduction in a margin of safety?The proposed change to the ice condenser flow channel surveillance provides additional assurance that the ice condenser should contain the'inimum analyzed flow area.By ensuring the minimum analyzed area is always available, inherent margins due to conservative assumptions in the calculation are maintained.
 
These conservative assumptions include, for example, taking no credit for ice or frost blockage being blown clear during the accident and assuming only one dimensional flow through the ice bed with no credit taken for cross flow.Therefore, these changes do not involve a significant reduction in a margin of safety.In summary, based upon the above evaluation, the Licensee has concluded that these changes do not involve a significant hazards consideration.
l W4 4
4 L ATTACHMENT 5 TO AEP:NRC: 09000 ENVIRONMENTAL ASSESSMENT Attachment 5 to AEP:NRC:09000 Page 1 Environmental Assessment The Licensee has evaluated this license amendment request against the criteria for identification of licensing and regulatory actions requiring environmental assessment in accordance with 10 CFR 51.21.The Licensee has determined that this license amendment request meets the criteria for a categorical exclusion set forth in 10 CFR 51.22(c)(9).
A I 's Il
This determination is based on the fact that this change is being proposed as an amendment to a license issued pursuant to 10 CFR 50 that changes a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or that changes an inspection or a surveillance requirement, and the amendment meets the following specific criteria.(i)The amendment involves no significant hazards consideration.
 
As demonstrated in attachment 4, this proposed amendment does not involve any significant hazards consideration.(ii)There is no significant change in the types or significant increase in the amounts of any effluent that may be released offsite.As documented in attachment 1, there will be no change in the types or significant increase in the amounts of any effluents released offsite.(iii)There is no significant increase in individual or cumulative occupational radiation exposure.II The proposed changes will not result in significant changes in the operation or configuration of the facility.There will be no change in the level of controls or methodology used for processing of radioactive effluents or handling of solid radioactive waste, nor will the proposal result in any change in the normal radiation levels within the plant~Therefore, there will be no increase in individual or cumulative occupational radiation exposure resulting from this change.
3/4      BASES 3/4,6    CONTAINMENTSYSTEMS 3/4,6.5 ICE.CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than 12 psig during LOCA conditions.
1.0 t'~t)H R}}
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will 1) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containment sump following the LOCA and
: 3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.
The minimum weight figure of 1333 pounds of ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.
The containment sub-compartment analysis assumes a 15% blockage throughout the ice condenser flow paths. The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the fiow area left between the crane wall and the coritainment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances. In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total fiow area in the bay. Flow channels in radial rows one and nine include the area between the basket
                                                                                                            -
and the containment and crane wall respectively. There are a total of 81 flow channels in each bay one per ice basket.
The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.
The 3/8" criterion for frost or ice accumulation in a flow channel provides only an indicator of ice condenser condition. The lattice frame thickness is 3/8" and, therefore, this dimension provides a convenient visual reference during flow channel inspections. Frost or ice build-up in excess of 3/8" shall be evaluated further by selecting a representative sample of 20 flow channels that spiral outward from the affected fiow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100% inspection of the bay and calculation to ensure that the 15% blockage limit is met.
Because  the minimum ice condenser fiow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vancs, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.
3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.
COOK NUCLEAR PLANT-UNITI                              Page B 3/4   64                        AMENDMENT480,           RRO
 
ATTACHMENT 3B TO AEP:NRC: 09000 PROPOSED TECHNICAL SPECIFICATIONS PAGES REVISED PAGES UNIT 2
 
4 3/4   LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCEREQUIREMENTS 3/4.6 CONTAINMENTSYSTEMS SURVEILLANCE RE UIREMENTS Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed. The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/basket at a 95% level of confidence.
The ice condenser shall also be subdivided into 3 groups of baskets, as follows:
Group 1 - bays 1 through 8, Group 2 - bays 9 through 16, and Group 3 - bays 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.
The minimum total ice condenser ice weight at a 95% level of confidence shall be calculated using all ice 'basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.
Verifying, by a visual inspection of at least four flow channels per ice condenser bay, that the accumulation of frost or ice on flow channels between ice baskets and past lattice frames is restricted to a nominal thickness of 3/8 inches. Flow channels will be selected as follows: two at random from radial rows 2 through 8 and one each from radial rows 1 and 9. If one flow channel per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional fiow channels from the same bay shall be visually inspected. If these additional flow channels are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable. More than one restricted flow channel per bay is evidence of abnormal degradation and will require a 100% inspection of that bay to determine, by calculation,.that the total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.
At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support structures and turning vanes, on the top deck floor grating and on the intermediate deck, is restricted to a nominal thickness of 3/8 inches. An accumulation of frost or ice greater than this thickness is evidence of abnormal degradation of the ice condenser.
At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage.         The ice baskets shall be raised at least 12 feet for this inspection.
COOK NUCLEAR PLANT-UNIT2                    Page 3/4 6-36                      AMENDMENT90, 485, %4
 
3/4      BASES 3/4.6    CONTAINMENTSYSTEMS 3/4:6.4 COMBUSTIBLE GAS CONTROL The OPERABILITYof the equipment and systems required for the detection and control of hydrogen gas ensures that this equipment will be available to maintain the hydrogen concentration within containment below its flammable limit during post-LOCA conditions. Either recombiner unit is capable of controlling the expected hydrogen generation associated with 1) zirconium-water reactions, 2) radiolytic decomposition of water and 3) corrosion of metals within containment. These hydrogen control systems are consistent with the recommendations of Regulatory Guide 1.7, "Control of Combustible Gas Concentrations in Containment Following a LOCA," March 1971.
3/4.6.5 ICE CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than 12 psig during LOCA conditions.
3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will 1) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containment sump following the LOCA and
: 3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.
The minimum weight figure of 1333 pounds of ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.
The containment sub~mpartmcnt analysis assumes a 15% blockage throughout the ice condenser flow paths. The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances. In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay. Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively. There are a total of 81 flow channels in each bay one per ice basket.
The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.
The 3/8" criterion for frost or ice accumulation in a flow channel provides only an indicator of ice condenser condition. The lattice frame thickness is 3/8" and, therefore, this dimension provides a convenient visual reference during flow channel inspections. Frost or ice build-up in excess of 3/8" shall be evaluated further by selecting a representative sample of 20 flow channels that spiral outward from the affected flow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100% inspection of the bay and calculation to ensure that the 15% blockage limit is met.
COOK NUCLEAR PLANT-UNIT2                              Page B 3/4  &4                AMENDMENT4, 464, 204, 2%
 
~, ~
u ~
        '
u
 
3/4      BASES 3/4,6    CONTAINMENTSYSTEMS Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.
3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.
COOK NUCLEAR PLANT-UNIT2                            Page B 3/4 6-5                    AMENDMENT4, 464, 204, 2%
 
~ ~
ATTACHMENT 4 TO AEP:NRC:09000 EVALUATION OF SIGNIFICANT HAZARDS CONSIDERATION
 
Attachment    4 TO  AEP:NRC:09000                                      Page 1 Evaluation of Si nificant Hazards Consideration The Licensee has      evaluated this proposed amendment and determined that it involves no significant hazards consideration. According to 10 CFR 50.92(c), a proposed amendment to an operating license involves no significant hazards consideration, if operation of the facility in accordance with the proposed amendment should not:
: 1. involve     a   significant increase      in the probability of occurrence      or  consequences    of   an  accident    previously evaluated;
: 2. create    the possibility of a new or different kind of accident from any previously analyzed; or
: 3. involve   a   significant reduction in      a  margin of safety.
The Licensee    proposes    to revise T/S 4.6.5.1b.3      and  4.6.5.1c, "Ice Condenser,    Ice Bed," and    its  associated  bases  for units    1 and 2.
The   proposed changes would revise the surveillance for ice condenser flow channels to provide reasonable assurance that blockage of flow channels is detected and evaluated to the maximum analyzed blockage of 15%. The bases                  are revised to reflect the changes to the T/S and to clarify the intent of additional representative sampling when blocked channels are detected.
The  determination that 'the criteria set forth in 10           CFR 50.92 are met  for this amendment request is indicated below.
: 1. Does    the   change     involve    a  significant    increase in the probability      or  consequences      of  an    accident previously evaluated?
The  ice condenser system is used to mitigate the consequences of an accident and has no impact on the initiation of any evaluated accidents.          Therefore, changing the flow channel surveillance does not increase the probability of an evaluated accident.
The proposed     changes  to the flow channel surveillance provide additional assurance        beyond current requirements to provide reasonable assurance that the maximum analyzed blockage of 15%
is not exceeded. Therefore, the change does not represent an increase in the consequences              of an accident previously evaluated.
: 2. Does the change create the possibility of a new or different kind of accident from any accident previously evaluated?
The proposed changes       do not create the   possibility of    a new or different kind of accident            from any    accident previously evaluated.     The ice condenser      has no function during normal operation.      It is a passive      system that functions after an
 
Attachment  4 TO  AEP:NRC:09000                                  Page 2 accident has already occurred. The proposed change to the ice condenser flow channel surveillance does not alter physical characteristics of the ice condenser, nor does        it  change the function of the ice condenser. No new failure mechanisms are introduced by this change.
Therefore, create the it was  concluded that the proposed changes possibility of  a new do not or different kind of accident from any previously evaluated.
: 3. Does the change involve a      significant reduction in  a  margin of safety?
The  proposed    change  to the ice condenser flow channel surveillance    provides additional assurance      that the ice condenser should contain the'inimum analyzed flow area.            By ensuring the minimum analyzed area is always available, inherent margins due to conservative assumptions in the calculation are maintained. These conservative assumptions include, for example, taking no credit for ice or frost blockage being blown clear during the accident and assuming only one dimensional flow through the ice bed with no credit taken for cross flow.
Therefore,    these changes      do not    involve  a    significant reduction in a margin of safety.
In summary, based upon the above evaluation, the Licensee has concluded that these changes do not involve a significant hazards consideration.
 
4 L
 
ATTACHMENT 5 TO AEP:NRC: 09000 ENVIRONMENTAL ASSESSMENT
 
Attachment      5 to  AEP:NRC:09000                                    Page  1 Environmental Assessment The Licensee      has evaluated    this license    amendment  request against the  criteria for identification of licensing                and regulatory actions    requiring environmental        assessment    in accordance with 10 CFR 51.21.        The Licensee has determined that this license amendment request meets the criteria for a categorical exclusion set forth in 10 CFR 51.22(c)(9). This determination is based on the fact that this change is being proposed as an amendment to a license issued pursuant to 10 CFR 50 that changes a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or that changes an inspection or a surveillance requirement, and the amendment meets the following specific criteria.
(i)  The        amendment      involves      no    significant      hazards consideration.
As demonstrated        in attachment    4,  this  proposed  amendment does not      involve any significant hazards consideration.
(ii)  There is no significant change in the types or significant increase in the amounts of any effluent that may be released      offsite.
As documented      in attachment 1, there will be no change in the types or significant increase in the amounts of any effluents released offsite.
(iii) There        is no significant increase in              individual    or cumulative occupational radiation exposure.
II The proposed changes        will not result in significant changes in the operation or configuration of the facility. There will be no change in the level of controls or methodology used for processing of radioactive effluents or handling of solid radioactive waste, nor will the proposal result in any change in the normal radiation levels within the plant              ~
Therefore, there will be no increase in individual or cumulative occupational radiation exposure resulting from this change.
 
1 t'
  .0        ~
t)
H R}}

Revision as of 11:59, 22 October 2019

Proposed Tech Specs 4.6.5.1, Ice Condenser,Ice Bed & Associated Bases,Reflecting Max Ice Condenser Flow Channel Blockage Assumed in Accident Analyses
ML17335A358
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 12/03/1998
From:
INDIANA MICHIGAN POWER CO.
To:
Shared Package
ML17335A357 List:
References
NUDOCS 9812080046
Download: ML17335A358 (27)


Text

ATTACHMENT 2A TO AEP:NRC: 09000 TECHNICAL SPECIFICATIONS PAGES MARKED TO SHOW PROPOSED CHANGES REVISED PAGES UNIT 1 3/4 6-27 B 3/4 6-4

'P8i208004b 98i203 PDR

3/4 LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6 CONTAINMENTSYSTEMS SURVEILLANCE RE UIREMENTS Continued shall be constituted of one basket each from Radial Rows I, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets O from the same bay shall bc weighed. The minimum average weight of ice from o ~gy the 20 additional baskets and the discrepant basket shall not be less, than 1333 pounds/basket at a 95% level of confidence.

O crt cl stg The icc condenser shall also be subdivided into 3 groups of baskets, as follows:

~O gO

~ Group 1 - bays I through 8, Group 2 - bays 9 through 16, and Group 3 - bays rn Ctg 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows I, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.

sts The minimum total ice condenser icc weight at a 95% level of confidence shall be calculated using all ice basket weights determined during this weighing

~Q~O sty program and shall not bc less than 2,590,000 pounds.

+g 4tD BBca 3. Verifying, by a visual inspection of at ieastinve fioutAptutsegee per ice condenser 4 8g bay, that the accumulation of frost or ice on

'a W4 flow between ice baskets and past lattice 0 g E E ig Qt rames is restrict to a nommal thickness of 3/8 inches. If one fiow+ssage-per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional flo rom the same ++

bay shall be visually inspected. If these additional flow I aesages are found O acceptable, thc surveillance program may proceed considering the singl'c

'o stg deficiency as unique and acceptable. More than one restricted flow paseeggg per Cd) bay is evidence of abnormal degradation C4 O

Q At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support str'uctures tunung vane 's restricted to a nominal thickness of 3/8 inches. An accumulation of frost

~

CJ or ice greater than this thickness is evidence of abnormal degradation of the ice 4C5 condenser.

O At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice O baskets are free of detrimental structural wear, cracks, corrosion or other damage. The ice baskets shall be raised at least 12 feet for this inspection.

and will require a 100% inspection of that bay to determine, by calculation, that thc total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a, LOCA or MSLB.

Gys& rs wK/

4 4 ghw~~a/~

COOK NUCLEAR PLANT-UNIT 1 Page 3/4 6-27 AMENDMENT408, AQUA, 438, 444, 220

3/4 BASES 3/4.6 CONTAINMENTSYSTEMS

'3/4.6.5 'ICE CON DENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than l2 psig during LOCA conditions.

3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will I) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containinent sump following the LOCA and

3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.

The minimum weight figure of 1333 pounds of ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.

3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.

COOK NUCLEAR PLANT-UNIT I Page B 3/4 &4 AMENDMENT480, 220

\

INSERT FOR PAGE B 3/4 6-4 (Unit 1)

The containment sub-compartment analyses assumes a 15% blockage throughout the ice condenser flow paths. The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances. In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay. Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively. There are a total of 81 flow channels in each bay one per ice basket.

The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.

The 3/8" frost or ice accumulation in a flow channel criterion provides only an indicator of ice condenser condition. The lattice frame thickness is 3/8", and therefore, this dimension provides a convenient visual reference during flow channel inspections. Frost or ice buildup in excess of 3/8" shall be evaluated by selecting a further representative sample of 20 flow channels that spiral outward from the affected flow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100% inspection of the bay and calculation to ensure that the 15% blockage limit is met.

Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to provide reasonable assurance that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.

ATTACHMENT 2B TO AEP:NRC:09000 TECHNICAL SPECIFICATIONS PAGES MARKED TO SHOW PROPOSED CHANGES REVISED PAGES UNIT 2

3/4 LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.6 CONTAINMENTSYSTEMS SURVEILLANCE RE UlREMENTS Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets O from the same bay shall be weighed. The minimum average weight of ice from Ctg O jlyO the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/ba'sket at a 95% level of confidence.

Vl The ice condenser shall also be subdivided into 3 groups of baskets, as follows:

~OQ Cto Group 1- bays 1 through 8, Group 2- bays 9 through 16, and Group 3- bays CO

~

cn Ctg 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.

cn tn The minimum total ice condenser ice weight at a 95% level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.

4 3. Verifying, by a visual inspection of at teastjttwe tlowgpassegee per ice condenser bay, that the accumulation of frost or ice on

'O flow between ice baskets and past lattice O

ty P. C rames is restrict to a noaunal ickness of 3/8 mches. If one flowjgssage-per bay is found to have an accumulation of. frost or ice greater than this tD thickness, a representative sample of 20 additional flo rom the same bay shal be visu~ly inspect~. If these addition~ flow ~mme are found C

O acceptable, the surveillance program may proceed considering the single

'O Ctg deficiency as unique and acceptable. More than one restricted flow passage per CO bay is evidence of abnormal degradation C

c, At least once per 18 months by verifying, by a visual inspection, of each ice condenser O bay, that the accumulation of frost or ice on the lower plenum support stiuctures andg O

turnmg van 's restricted to a nominal thickness of 3/8 inches. An accumulation of frost O or ice greater than this thickness is evidence of abnormal degradation of the ice

'a condenser.

O O

At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice O baskets are free of detrimental structural wear, cracks, corrosion or other damage. The ice baskets shall be raised at least 12 feet for this inspection.

nate,/

and willrequire a 100% inspection of that bay to determine, by calculation, that the total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.

vV &tlap Q 4 4Cj~nna/X COOK NUCLEAR PLANT-UNIT2 Page 3/4 6-36 AMENDMENTQO, 42$ , 204

3/4 BASES 3/4.6 CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL

'L ~

The OPERABILITY of the equipment and systems required for the detection and control of hydrogen gas ensures that this equipment will be available to maintain the hydrogen concentration within containment below its flammable limit during post-LOCA conditions. Either recombiner unit is capable of controlling the expected hydrogen generation associated with: I)'zirconium-water reactions; 2) radiolytic decomposition of water; and 3) corrosion of metals within containment. These hydrogen control systems are consistent with the recommendations of Regulatory Guide 1.7, "Control of Combustible Gas Concentrations in Containment Following a LOCA," March 1971.

The acceptance criterion of 10,000 ohms is based on the test being performed with the heater element at an ambient temperature, but can be conservatively applied when the heater element is at a temperature above ambient.

3/4.6.5 ICE CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak prcssure transient to less than 12 psig during LOCA conditions.

3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will I) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containment sump following the LOCA and

3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.

The minimum weight figure of 1333 pounds of, ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.

3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.

COOK NUCLEAR PLANT-UNIT 2 Page B 3/4 64 AMENDMENT 4, 444, 104, 207

INSERT FOR PAGE B 3/4 6-4 (Unit 2) l The containment sub-compartment analyses assumes a 15% blockage throughout the ice condenser flow paths. The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that ele'vation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances. In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay. Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively. There are a total of 81 flow channels in each bay one per ice basket.

The selection of one flow channel each, from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.

The 3/8" frost or ice accumulation in a flow channel criterion provides only an indicator of ice condenser condition. The lattice frame thickness is 3/8", and therefore, this dimension provides a convenient visual reference during flow channel inspections. Frost or ice buildup in excess of 3/8" shall be evaluated further by selecting a further representative sample of 20 flow channels that spiral outward from the affected flow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100%

inspection of the bay and calculation to ensure that the 15%

blockage limit is met.

Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations, . the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.

ATTACHMENT 3A TO AEP:NRC: 09000 PROPOSED TECHNICAL SPECIFICATIONS PAGES REVISED PAGES UNIT 1

3/4 LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCEREQUIRIMENTS 3/4.6 CONTAINMENTSYSTEMS Surveillance.Re uirements Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed. The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/basket at a 95% level of confidence.

The ice condenser shall also be subdivided into 3 groups of baskets, as follows:

Group 1- bays 1 through 8, Group 2- bays 9 through 16, and Group 3- bays 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.

The minimum total ice condenser ice weight at a 95% level of confidence shall be calculated using all ice basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.

Verifying, by a visual inspection of at least four flow channels per ice condenser bay, that the accumulation of frost or ice on flow channels between ice baskets and past lattice frames is restricted to a nominal thickness of 3/8 inches. Flow channels will be selected as follows: two at random from radial rows 2 through 8 and one each from radial rows 1 and 9. If one flow channel per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional flow channels from the same bay shall be visually inspected. If these additional flow channels are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable. More than one restricted flow channel per bay is evidence of abnormal degradation and will require a 100% inspection of that bay to determine, by calculation, that the total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.

At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower inlet plenum support structures and taming canes, on the top deck floor grating and on the intermediate deck, is rmtricted to a nominal thickness of 3/8 inches. An accumulation of frost and ice greater than this thickness is evidence of abnormal degradation of the ice condenser.

At least once per 40 months by lifting arid visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage. The ice baskets shall be raised at least 12 feet for this inspection.

COOK NUCLEAR PLANT-UNIT1 Page 3/4 6-27 AMENDMENT408, 4Skp 488, 444p 220

l W4 4

A I 's Il

3/4 BASES 3/4,6 CONTAINMENTSYSTEMS 3/4,6.5 ICE.CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than 12 psig during LOCA conditions.

3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will 1) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containment sump following the LOCA and

3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.

The minimum weight figure of 1333 pounds of ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.

The containment sub-compartment analysis assumes a 15% blockage throughout the ice condenser flow paths. The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the fiow area left between the crane wall and the coritainment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances. In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total fiow area in the bay. Flow channels in radial rows one and nine include the area between the basket

-

and the containment and crane wall respectively. There are a total of 81 flow channels in each bay one per ice basket.

The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.

The 3/8" criterion for frost or ice accumulation in a flow channel provides only an indicator of ice condenser condition. The lattice frame thickness is 3/8" and, therefore, this dimension provides a convenient visual reference during flow channel inspections. Frost or ice build-up in excess of 3/8" shall be evaluated further by selecting a representative sample of 20 flow channels that spiral outward from the affected fiow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100% inspection of the bay and calculation to ensure that the 15% blockage limit is met.

Because the minimum ice condenser fiow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vancs, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.

3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.

COOK NUCLEAR PLANT-UNITI Page B 3/4 64 AMENDMENT480, RRO

ATTACHMENT 3B TO AEP:NRC: 09000 PROPOSED TECHNICAL SPECIFICATIONS PAGES REVISED PAGES UNIT 2

4 3/4 LIMITINGCONDITIONS FOR OPERATION AND SURVEILLANCEREQUIREMENTS 3/4.6 CONTAINMENTSYSTEMS SURVEILLANCE RE UIREMENTS Continued shall be constituted of one basket each from Radial Rows 1, 2, 4, 6, 8 and 9 (or from the same row of an adjacent bay if a basket from a designated row cannot be obtained for weighing) within each bay. If any basket is found to contain less than 1333 pounds of ice, a representative sample of 20 additional baskets from the same bay shall be weighed. The minimum average weight of ice from the 20 additional baskets and the discrepant basket shall not be less than 1333 pounds/basket at a 95% level of confidence.

The ice condenser shall also be subdivided into 3 groups of baskets, as follows:

Group 1 - bays 1 through 8, Group 2 - bays 9 through 16, and Group 3 - bays 17 through 24. The minimum average ice weight of the sample baskets from Radial Rows 1, 2, 4, 6, 8 and 9 in each group shall not be less than 1333 pounds/basket at a 95% level of confidence.

The minimum total ice condenser ice weight at a 95% level of confidence shall be calculated using all ice 'basket weights determined during this weighing program and shall not be less than 2,590,000 pounds.

Verifying, by a visual inspection of at least four flow channels per ice condenser bay, that the accumulation of frost or ice on flow channels between ice baskets and past lattice frames is restricted to a nominal thickness of 3/8 inches. Flow channels will be selected as follows: two at random from radial rows 2 through 8 and one each from radial rows 1 and 9. If one flow channel per bay is found to have an accumulation of frost or ice greater than this thickness, a representative sample of 20 additional fiow channels from the same bay shall be visually inspected. If these additional flow channels are found acceptable, the surveillance program may proceed considering the single deficiency as unique and acceptable. More than one restricted flow channel per bay is evidence of abnormal degradation and will require a 100% inspection of that bay to determine, by calculation,.that the total flow passage blockage is less than the 15% assumed in the analysis of lower subcompartment pressurization following a LOCA or MSLB.

At least once per 18 months by verifying, by a visual inspection, of each ice condenser bay, that the accumulation of frost or ice on the lower plenum support structures and turning vanes, on the top deck floor grating and on the intermediate deck, is restricted to a nominal thickness of 3/8 inches. An accumulation of frost or ice greater than this thickness is evidence of abnormal degradation of the ice condenser.

At least once per 40 months by lifting and visually inspecting the accessible portions of at least two ice baskets from each 1/3 of the ice condenser and verifying that the ice baskets are free of detrimental structural wear, cracks, corrosion or other damage. The ice baskets shall be raised at least 12 feet for this inspection.

COOK NUCLEAR PLANT-UNIT2 Page 3/4 6-36 AMENDMENT90, 485, %4

3/4 BASES 3/4.6 CONTAINMENTSYSTEMS 3/4:6.4 COMBUSTIBLE GAS CONTROL The OPERABILITYof the equipment and systems required for the detection and control of hydrogen gas ensures that this equipment will be available to maintain the hydrogen concentration within containment below its flammable limit during post-LOCA conditions. Either recombiner unit is capable of controlling the expected hydrogen generation associated with 1) zirconium-water reactions, 2) radiolytic decomposition of water and 3) corrosion of metals within containment. These hydrogen control systems are consistent with the recommendations of Regulatory Guide 1.7, "Control of Combustible Gas Concentrations in Containment Following a LOCA," March 1971.

3/4.6.5 ICE CONDENSER The requirements associated with each of the components of the ice condenser ensure that the overall system will be available to provide sufficient pressure suppression capability to limit the containment peak pressure transient to less than 12 psig during LOCA conditions.

3/4.6.5.1 ICE BED The OPERABILITY of the ice bed ensures that the required ice inventory will 1) be distributed evenly through the containment bays, 2) contain sufficient boron to preclude dilution of the containment sump following the LOCA and

3) contain sufficient heat removal capability to condense the reactor system volume released during a LOCA. These conditions are consistent with the assumptions used in the accident analyses.

The minimum weight figure of 1333 pounds of ice per basket contains a 5% conservative allowance for ice loss through sublimation. In the event that observed sublimation rates are equal to or lower than design predictions after three years of operation, the minimum ice baskets weight may be adjusted downward. In addition, the number of ice baskets required to be weighed each 18 months may be reduced after 3 years of operation if such a reduction is supported by observed sublimation data.

The containment sub~mpartmcnt analysis assumes a 15% blockage throughout the ice condenser flow paths. The minimum ice condenser flow area through each bay occurs at the lattice frame support elevations, and includes the net open area at these support elevations. This includes the flow area left between the crane wall and the containment wall inside surfaces, after subtracting out the areas for the ice condenser equipment at that elevation, that includes ice baskets full of ice, lattice frame, lattice frame columns, wall panel air ducts and wall panel cradles and other appurtenances. In summary, a flow channel consists of the annular area outside of each basket and one-half of the triangular areas formed by the lattice supports between baskets, such that the sum of these areas around each basket equals the total flow area in the bay. Flow channels in radial rows one and nine include the area between the basket and the containment and crane wall respectively. There are a total of 81 flow channels in each bay one per ice basket.

The selection of one flow channel each from radial rows 1 and 9 assures that the inspection should include those areas where, based on experience, it is expected to see frost build-up first.

The 3/8" criterion for frost or ice accumulation in a flow channel provides only an indicator of ice condenser condition. The lattice frame thickness is 3/8" and, therefore, this dimension provides a convenient visual reference during flow channel inspections. Frost or ice build-up in excess of 3/8" shall be evaluated further by selecting a representative sample of 20 flow channels that spiral outward from the affected flow channel. This sample population assures that the areas around and adjacent to the blocked channel are also inspected. More than one restricted flow channel per bay requires a 100% inspection of the bay and calculation to ensure that the 15% blockage limit is met.

COOK NUCLEAR PLANT-UNIT2 Page B 3/4 &4 AMENDMENT4, 464, 204, 2%

~, ~

u ~

'

u

3/4 BASES 3/4,6 CONTAINMENTSYSTEMS Because the minimum ice condenser flow area in each ice condenser bay occurs at the lattice frame support elevations, the inspection of the lower inlet plenum support structures and turning vanes, top deck floor grating and intermediate deck also provides only an indicator of the overall ice condenser condition. The 3/8" thickness criterion provides a threshold to ensure that any frost or ice buildup is corrected well before the 15% blockage assumption is approached in these areas.

3/4.6.5.2 ICE BED TEMPERATURE MONITORING SYSTEM The OPERABILITY of the ice bed temperature monitoring system ensures that the capability is available for monitoring the ice temperature. In the event the monitoring system is inoperable, the ACTION requirements provide assurance that the ice bed heat removal capacity will be retained within the specified time limits.

COOK NUCLEAR PLANT-UNIT2 Page B 3/4 6-5 AMENDMENT4, 464, 204, 2%

~ ~

ATTACHMENT 4 TO AEP:NRC:09000 EVALUATION OF SIGNIFICANT HAZARDS CONSIDERATION

Attachment 4 TO AEP:NRC:09000 Page 1 Evaluation of Si nificant Hazards Consideration The Licensee has evaluated this proposed amendment and determined that it involves no significant hazards consideration. According to 10 CFR 50.92(c), a proposed amendment to an operating license involves no significant hazards consideration, if operation of the facility in accordance with the proposed amendment should not:

1. involve a significant increase in the probability of occurrence or consequences of an accident previously evaluated;
2. create the possibility of a new or different kind of accident from any previously analyzed; or
3. involve a significant reduction in a margin of safety.

The Licensee proposes to revise T/S 4.6.5.1b.3 and 4.6.5.1c, "Ice Condenser, Ice Bed," and its associated bases for units 1 and 2.

The proposed changes would revise the surveillance for ice condenser flow channels to provide reasonable assurance that blockage of flow channels is detected and evaluated to the maximum analyzed blockage of 15%. The bases are revised to reflect the changes to the T/S and to clarify the intent of additional representative sampling when blocked channels are detected.

The determination that 'the criteria set forth in 10 CFR 50.92 are met for this amendment request is indicated below.

1. Does the change involve a significant increase in the probability or consequences of an accident previously evaluated?

The ice condenser system is used to mitigate the consequences of an accident and has no impact on the initiation of any evaluated accidents. Therefore, changing the flow channel surveillance does not increase the probability of an evaluated accident.

The proposed changes to the flow channel surveillance provide additional assurance beyond current requirements to provide reasonable assurance that the maximum analyzed blockage of 15%

is not exceeded. Therefore, the change does not represent an increase in the consequences of an accident previously evaluated.

2. Does the change create the possibility of a new or different kind of accident from any accident previously evaluated?

The proposed changes do not create the possibility of a new or different kind of accident from any accident previously evaluated. The ice condenser has no function during normal operation. It is a passive system that functions after an

Attachment 4 TO AEP:NRC:09000 Page 2 accident has already occurred. The proposed change to the ice condenser flow channel surveillance does not alter physical characteristics of the ice condenser, nor does it change the function of the ice condenser. No new failure mechanisms are introduced by this change.

Therefore, create the it was concluded that the proposed changes possibility of a new do not or different kind of accident from any previously evaluated.

3. Does the change involve a significant reduction in a margin of safety?

The proposed change to the ice condenser flow channel surveillance provides additional assurance that the ice condenser should contain the'inimum analyzed flow area. By ensuring the minimum analyzed area is always available, inherent margins due to conservative assumptions in the calculation are maintained. These conservative assumptions include, for example, taking no credit for ice or frost blockage being blown clear during the accident and assuming only one dimensional flow through the ice bed with no credit taken for cross flow.

Therefore, these changes do not involve a significant reduction in a margin of safety.

In summary, based upon the above evaluation, the Licensee has concluded that these changes do not involve a significant hazards consideration.

4 L

ATTACHMENT 5 TO AEP:NRC: 09000 ENVIRONMENTAL ASSESSMENT

Attachment 5 to AEP:NRC:09000 Page 1 Environmental Assessment The Licensee has evaluated this license amendment request against the criteria for identification of licensing and regulatory actions requiring environmental assessment in accordance with 10 CFR 51.21. The Licensee has determined that this license amendment request meets the criteria for a categorical exclusion set forth in 10 CFR 51.22(c)(9). This determination is based on the fact that this change is being proposed as an amendment to a license issued pursuant to 10 CFR 50 that changes a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or that changes an inspection or a surveillance requirement, and the amendment meets the following specific criteria.

(i) The amendment involves no significant hazards consideration.

As demonstrated in attachment 4, this proposed amendment does not involve any significant hazards consideration.

(ii) There is no significant change in the types or significant increase in the amounts of any effluent that may be released offsite.

As documented in attachment 1, there will be no change in the types or significant increase in the amounts of any effluents released offsite.

(iii) There is no significant increase in individual or cumulative occupational radiation exposure.

II The proposed changes will not result in significant changes in the operation or configuration of the facility. There will be no change in the level of controls or methodology used for processing of radioactive effluents or handling of solid radioactive waste, nor will the proposal result in any change in the normal radiation levels within the plant ~

Therefore, there will be no increase in individual or cumulative occupational radiation exposure resulting from this change.

1 t'

.0 ~

t)

H R