Cook Nuclear Plant Restart Plan

~>> /9t Revision 0 S. R. Sampson Site Vice-President 9904130177 990405 PDR ADQCK 050003'L5 P

POR

0

ok Noclear Plant Restart Plan 1.

Introduction and Overview 1.1 Purpose

1.2 Background

1.3 Roles and Responsibilities 1.4 Cook Nuclear Plant Restart Piocess Overview 2.

Restart Work Scope Determination 2.1 Restart Work Scope Determination Process 2.2 Plant System Reviews 2.3 Redefined Restart Work Scope 3...

Restart Work Scope Performance 3.1 Work Scope Performance Restart Readiness Assessmeat 4.1 4.2 4.3 4.4 System Reidiness Functional Arei Readiness Programmatic Readiness Containment Raidiness 5., Restart Authorization 5.1 Restart Oversight Committee(ROC) Review and Approval 5.2 Senior Matutger Review Team (SMRT) Review and Approval 5.3 Executive Vice Presideat Restart Authorization 6.

Startup and Power Ascension 6.1 Managemeat Oversight and Organizational Support 6.2 OperatinS Pro6cieacy and Experieace Review Attachments:

A system engineer review board (SERB) charter B restart oversight committee (ROC) charter C criteria for work included in restart scope D plant systems to be reviewed by ROC E restart process map

1.0 Introduction and Overview 1.1 Purpose ls that will The Cook Nuclear Plant Restart Plan describes the activities and controls that wi be implemented to ensure the facility is ready to safely start up and operate in an event free manner. To provi e us wi

. T

'd with the assurance that this can be accomplished eread to meet this we.m ust determine that our people, plant and programs are ready to meet is challenge.

The plan willassess these areas and identify any need ceded action to ensure we can safely startup and operate reliably in an event free manner.

The plan willassess the following:

People Have we adequately prepared our people such that they are trained on the changes d

ed es and understand the issues involved in restarting and operating the plant? Are the functional areas staffed, organized and functioning at a eve to suppo s

1 1

rt afe startup and reliable operation in an event free manner?

Programs ams and procedures been adjusted to include the lessons learned?

Have our programs an proc Are they adequate to allow us'to return to operation and prevent future nonconforming conditions?

Plant

're our materie con i 'o dition, configurations, restart readiness ofsystems and abihty to meet design function while complying with applicab e regu ations equa allow us to return to service?

This plan provides a map to conduct the assessments needed to assure ourselves ead estab The actions and activities needed to do this and any roved rocedures.

corrective actions willbe performed in accordance with approv p

ures.

1.'2 Bachgjroaad Duri th Jul - September, 1997, time&arne, the NRC conducted an architect en

'nspection at Cook Nuclear Plant The AE inspection focused the core during a design basis accident. As a conservative measure, bo units were shut down on September 9 and cooled to cold shut down until this question could be properly answered.

tember 12 the NRC concluded the AE inspection with a public exit On Septem er, e.

t committed to addressing and meeting.

Following this meeting, Cook Nuclear Plant commi the ins

'on rior to restart o resolving seven {7) specific issues identified during e i pecti p

the units. It was believed that these seven issues could be resolved within a few 1

to the NRC committing to these actions, the NRC issued a confirmatory action letter {CAL)identifying their approv wou e

th

'ts. The i4RC CALalso identified two additional required prior to restarung the units.

e i actions to be taken as a condition for resorting the units.

The unit 2 reactor was sc heduled for a refueling to begin in late September, 1997.

was withia two weeks ofnormal burn up window at the time o e

fthe The unit 2 core was wi

'a two wee items and restart cheduled shut down. Our objecnve was to resolve the CAL items, an res uasc u

s unit 2 for the remaining two weeks offuel burn up, then commence the refueling outage.

Over the next several weeks, it became apparent that a restart would not be achievable in e near term, an th term, and a decision was made to begin the unit 2 refueling d its scheduled work on October 20, 1997. In parallel with the outage outage and its s wo work, our organization worked through the many iaspectio AE ias

'on/CAL issues. It appeared that a January 1998 restart ofboth units would be feasible.

Durin the time period of January - February 1998, the Cook Nuclear Plant senior management team had several meetings wi e, an e

nearing reso ution.

was luti

. It was during this time period that several new issues arose, icant concerning or re atmg our co 1 tin to our containment systems that would require signifi resources and focus to recoacile.

Given the sigaizicaat peri th

'gaif t period that both units had been shut down up to this point, and the uncertainty for a near-tenn start up date, it was decided that e scope o o

es needed to be revaluated, and a more rigorous assessment ofplant readiness was required prior to any restart.

These steps ary

're access in order to achieve the objectives described in Section 1.1. The key factors that led to this decision are:

Design basis concerns aad equipmeat performance testiag

'ad

'ssues which have come to i~ in recent mo 1 ght recent moaths raised the concern that additional hardware

'xteaded and non-hardware activities may need to be completed during ttus extead shut down.

Coafirmatioa is required that procedure inadequacies or equipment deficieacies that may challenge plant operators during normal, abnormal erg abaorm ot emergency conditions have been adequately identified and addressed.

in gn o 'n extended shutdown 1

ed Gom other nuc)ear utilities in the implementation ofan integnexl assessment ofreadiness to restart followingan

period are being adopted and applied to Cook Nuclear Plant on a pilot basis during this outage.

1.3 Roles and Responsibilities Roles and responsibilities for the execution of this plan are as follows:

1.3.1 AllNuclear Generation Employees Responsible for supporting the restart activities by focusing on safe d

ti uous improvement. Allemployees are obligated to u

the raise any and all quality concerns to management's action through e

corrective action program.

1.3.2 System Engineers Responsible forsuccess&I completion ofrestart work on selected systems, safe, reliable power operations, implementing necessary corrective actions and providing af5rmation ofreadiness.

1.3.3 System Engineering Review Board (SERB)

Board internal to the engmeering organization res ponsible for assessing the readiness ofplant systems an provi '

1 stems and providing recommendations for additional restart scope to the ROC. The SERB charter is provided in attachment A.

'1.3.4 Restart Oversight Committee (ROC)

Responsible for determining the restart scope ofwork using consistent standards and criteria approved by the senior management review team (SMRT) and assessing the readiness of Cook Nuclear Plant to restart and resume power operations, using the process approved by the SMRT in this procedure.

The ROC charter is ptovided in attacluneat B.

'.3.5 Senior Management Review Team (SMRT)

Members:

Site Vice Ptesident (Chairman)

Vice President Nuclear Engineering Director Performance Assurance

'hdependent Safety Review Committee Member

'This member willactively participate as available, and willperform a continuous overs 1got fo e.

'ght 1

. Routine communication with this member may

be accomplished through review of meeting minutes, phone conferencing and followup interviews with the SMRT members.

The SMRT is responsible for generation and approvals of:

{a) criteria for screening work items required for completion of restart; (b) monitoring and oversight of the process for affirmation and approval ofplant and staff readiness for restart.

1.3.6 Plant Manager, Engineering Managers and Departm and D artment Superintendents Responsibility for success&1 completion ofthe restart work, performing an reliable power operations, implementing necessary corrective actions and providing aKrmation ofreadiness to the ROC.

1.3.7 Restart Manager Responsibility for the management and control ofrestart work activities including the scheduling ofactivities and coordination ofresources.

1.3.8 Site Vice President Overa0 res nsibility for the management and implementation ofthe restart Overa0 respons>> i or 1.1.

Serves as chairman of p an lan to achieve the purpose described m section the(SMRT).

1.3.9 Executive Vice President Nuclear Geaeration Res ponsible for authorizing startup and power ascension, and providmg senior management oversight ofthe restart process.

1A Cook Nuclear Plant Re>tart Process Overview'he restart plan consists ofthe followingmajor activities:

(1) scope determination (2}

work performance (3) readiness assessment (4) startup authorization (5) startup and power asceM ion Following is a process map an summ d summary ofthe activities with more detailed information presented in later sections ofthis document.

0

Cook Plant Restart Plan Overview I I age enfant I ~

te approve Restart Work BOOPO XI aeelert aerreerp Psrtorm Restart Work Pertorm F mal RIN>>w Racommena Statup tacit ReonmmendReatan hrrthoruC Restart 1 I l opireeerre lteatart An>

pcrkrm Gxaarnmerl

~ Rrprtsre

0

Restart Readiness A~sse sments 1.1 Sye Engr'~

I Perform System Readiness Reviews The objective of the restart readiness assessment is to ensure that the integrated set of plant equipment, human resources and work programs are capable of supporting safe and reliable power operations.

The restart readiness assessment will be initiated in parallel with the execution and completion of restart work.

The restart readiness assessment will focus on the following 1,2 i

M argon Perform Functional Area Readiness Reviews plant system readiness functional area readiness

~

ptogrammatic readiness e

containment readiness 1.3 Managera Perform Programmatic Readiness Reviews 1A Oir Pient Engineenng Perform Containment Readiness Reviews 1.$

SERB Recommend Restart Work Scope The restart work scope may be increased as a result of the plant system assessments or other ongoing work. The system engineers willrecommend the restart work scope to the System Engineer Review Board {SERB).

16 ROC All restart scope additions will be approved by the Restart Oversight Comminee (ROC).

Approve Restart Work !

Scope 2.t Restart Mareger

'erform Restart Work Following determination ofthe restart work scope by the ROC, the restart manager is responsible for coordinating the planning, scheduling and completion ofthe work.

3.1 ROC, PNSRC

. Perform Final Review Recommend Startup Results of the restart assessment will be presented to the Restart Oversight Committee (ROC) with an affirmation by the responsible system engineer or engineering

manager, and the functional area superintendent of the readiness of the system or organization to support plant startup and safe, reliable power 0perafions.

SMRT Recommend Restart Following presentation and acceptance of the assessment results by the ROC, the Site Vice President will convene the SMRT to perform an integrated review of the affirmations, verify compliance with regulatory commitments and any other special criteria that may impact the initiation ofstartup activities.

4.2 Exec Vrce Prea Authorize Restart Based on the results ofthis review, the Executive Vice President Nuclear Engineering wi0 authorize startup and power ascension.

5.1 OPS Startup and Power Ascension Startup and power ascension followingthe completion ofstartup work willfollowa deliberate and ctmtrulied approach that ensures operational and personnel safety. The normal startup process defined in Cook Nuclear Plant procedures willbe supplemented with appropriate management oversight and support fiom engineering and maintenance organization such that issues or concerns are promptly addressed and the startup can be accomplished in a safe, contmlled manner.

2.0 Restart cwork Scope Determination 2.1 Restart Work Scope Determination Process Th estart work scope is being defined through a determination process driven by ere w

the ROC consistent with their charter.

Outstanding work items an se programmatic issues are reviewed against defined criteria to determine which items should be included in the restart scope.

System engineers have the largest role in b

there is also considerable involvement from other organizations work sco e

including operations, design engineering, and maintenance.

The restart P

determination process is outlined in attachment E.

2.2 Plant System Review Plant systems are reviewed by the system engineer using the plant system review instructions with results and recommendations presented to the ROC.

The plant system review process consists offour primary elements as described below 2.2.1 Selection ofPlant Systems Plant systems have been selected for a detailed review and afFirmation based on the historical performance and risk significance ofthe system.

readiness review instructions.

Results ofthe assessment ofselected systems willbe esented Gr3t to the SERB and, upon approval, to the ROC with appropriate recommendations for additional actions e

to be ~ormed after restart The systems are listed in attachment D.

Th remaining systems willbe assessed and evaluated as part ofthe hne

, responsibility ofthe engineering organization through the use ofthe Issues that afFect restart scope on these systems willbe presented to the ROC on a case basis.

2.2.2 Restart Work Scope Additions The restart work scope addition for plant systems is focu.ied on those items not already included in the restart work scope.

Items already scheduled for letio prior to restart are not evaluated agiunst the criteria provided in attachment C unless there is a proposal to delete them. The go o

system review and wt,rk scope addition process is to define the work necessary for completion prior to restart such that the system is capable of supporting safe and reliable power operation.

This review ew willinclude the following:

0

(a) the magnitude, significance and risk of items which willbe resolved after restart should be defined and evaluated; (b) assurance that recurring problems on the system that could aff'ect safe and reliable operations are being fixed;

{c) assurance that any design basis and licensing issues on the system are being addressed within a time frame that is appropriate for the issue; and (d) assurance that operators willnot be unnecessarily challenged in'he operation ofthe system during normal, abnormal, or emergency conditions.

Based on the review ofopen work items against the criteria presented in attachment C, the system engineer is to provide recommen'dations for the restart scope changes for the selected systems in attachment D to the SERB

-and upon approval to the ROC. Items recommended for addition to the restart scope for remaining plant systems willbe handled on an item specific basis by the ROC followingan initial review by line management It should be noted that it was not the intent ofthis program to resolve all design basis issues.

We are committed to a long range program to accomplish this resolution."

n 2.2.3 Monitoring Restart Work, Addressing Emergent Issues and Performing a More Detailed Assessment ofSystem Readiness, System engineering is to monitor the progress ofwork on assigned system and address emergent issues as required. Any major restart scope impacts defined by emergent issues should be brought to the ROC following line management review. Allother emergent issues are assessed daily by the engineermg managers.

Also, the system engineer is to use this period to complete the assessment and evaluation ofsystem readiness in preparation forthe final system readiness review and affirmation ofreadiness for restart 2.2.4 Final System Readiness Review and Affirmation This aspect ofthe system readiness review process is summarized in section 4.1. Although it is not expected that any significant restart work scope issues willbe identified during this final review, ifany are identified, they are to be brought to the immediate attention ofthe ROC {followingline management review).

10

0

0 22 Redefined Restart Work Scope The restart work scope may be redefined based on the evaluation process described above. Decisions made by the ROC regarding the restart work scope are documented in meeting minutes and work item status is tracked.

3.0 Restart Work Scope Performance 3.1 Work Scope Performance Following determination of the restart work scope by the ROC, the restart manager is responsible for coordinating the planning, scheduling and completion ofthe work, including the implementation ofprogrammatic changes.

The restart work scope performance process is outlined in attachment E.

4.0 Restart Readiness Assessment The restart readiness assessment is an integrated line managemeat assessment that assists station management in etermining det

'ng the readiness to initiate startup and achieve safe, reliable power operation e n through the next operating cycle. Thc restart readiness assessmeat tofa process isoutlined inattaciunentE.

Thisformofassessmeatisoneelemeato a

comprehensive plant assessment program that is the foundation ofour continuous h'1 h

. Implementation ofthis action is consistent with the experience and lessons learned ofothe'nuclear utilities. The restart readiness assessmea g

implemented at Cook Nuclear Plant based on lessons learned and willbe captured such that this process can be implemented on a routine basis in thc future.

The restart readiness assessmeat forrestart willverify the co p

m letioa of a!1 defined restart operations.

Results ofthc asscssmeat and afRmation ofreadiness willbe presented to the supervisor. Following acceptance by thc ROC, thc site vice president willconvene an SMRT meeting to review these a6irmations aad vaify compliaace regulatory coaunrtmeats an any d

other applicable criteria The site vice presideat willrecommead start up ofthe units based on this review, and assuaiacc rcgardiag the readiness o statioa to iaitiate startup and safely, reliably operate though the next olxritingcycle.

Following is a summary ofthe key elements ofthe program.

4.1 System Readiness System readiness a6irmations by thc system engineer are to confirm that plant eet functional desiga requiremeats, have beea suitably tested'and as@

systems meet ready to support safe and reliable startup and operation through y

the next c cle. This aQirmation is based on thc work completed as described in section 2.2, and is to

include a coordinated system walkdown ofthe system with operations and maintenance personnel on systems defined by the plant engineering manager.

%here necessary, compensatory actions for reschedu ed w r 1

work or other areas of performance risk are to be defined and addressed.

S ead' affirmations are to be presented by'he system engineer to the SERB and upon its approval to the ROC for the systems identifi ystem r iness Affirmationofsystem readiness is documented with the signature of the system engineer an manage'r.

um d

'. Affirmationof individual system readiness for the remaining plant systems wi e

'll b addressed as part ofthe system engineering line management responsi i ity an wi

'b'1'

'll be one element ofthe functional area readiness evaluation.

4.2 Functional Area Readiness Functional area

'ss y se readiness b

selected functional areas is an affirmation that the startu and safe and d

artment is in an appropriate state ofreadiness to support startup an s

e an reliable power operation ou e

thr gh th next cycle. Functional area readiness wi0 include items such as:

(a) adequacy ofsta8iag levels, personnel expcnence and q~ications to demonstrate compliance with regulatory requirements and commitments; (b) completion ofpersonnel training on normal startup evaluations, power ascension requirements, industry operating experienc including extended shutdown and unusual events at similar plants, emergency preparedness, changes in plant configuration, changes in plant operating and emergency procedures, and changes in key administrative procedures and processes; (c) resolution ofsignificant performance deficiencies and reduction of backlogs (corrective action, corrective maintenance etc. ) to manageable levels; and (d) establishment ofgoals and priorities for the continued improvement ofthe department including use ofcritical assessment methods.

Functional Area readiness willbe a6irmcd to the ROC by the folhwingfunctional outage management

~

opcfatioIs

~

licensing plant cngtncenng

- fuels

~

design cngHlccnng plant pmtecnon man ent roduction engineerin information managemen

~

p uc plant performance assurance

~

chemistry radiation pmtectioa cof the Affirmationoffunctional area readiness is documented with the signature o e

functional area manager.

12

43 Programmatic Readiness Pro ammatic readiness review willconfirm that programs are in place to support identification and correction of problems.

Program the unit shutdown have been evaluated and necessary corrective or preventive h

b m leted. Programs in place at the time ofunit start-up will its desi bases and in ensure that the plant willbe operated in conformance with its esign accordance with the AEP quality assurance prOgra.

A/E prograinmatic issues potential bypass of 50.59 safety evaluations 50.59 safety evaluation quality corrective action program improvements surveillance program assessment 4.4 Containment Readiness the review willfocus on the system materiel condition, adequate surveillance testing, and the system configuration contro.

5.0 Restart Authorization The restart authorization process is outlined in attachment E.

5.1 Restart Oversight Committee (ROC) Review <<nd Approval Th ROC willreview and accept the assessment affirmatioas

'onsin 4.1 4.,4.3 and 4.4. Arestart recommendation willbe made to the SMRT as e

wi based on the results of the functional area assessments.

5D Senioc Mana~a Review Team (SMRQ Review and Approval U

review and acceptance ofthe assessment affirm revi ations in 4.1, 4.2, 4.3 and 4.4 by the ROC, the site vice president willconvene an SMRT meeting meetin to orm an integrated review and approval.

5B Ereeudve Vice President Restart Authorization Based on this review the executive vice president nuclear generation willprovide the authorization for restart and power ascension.

13

6.0 Startttp and Power Ascension Startup and power ascension, followingthe completion ofththe restart work willfollow a d I'b ate and controlled approach that ensures operational and personnel safety. The ei er ean normal startup management team willbe augmented with a shiA plan m

ag t man er and shift h that '

es or concerns are promptly addressed and the status can be accomplished in a safe, controlled manner.

The startup and power ascension actions summarized in this section do not change o. alter any requirements ofthe startup procedures defined above.

6.1 Management Oversight and Organizational Support The Cook Nuclear Plant management structure willbe supplemented with a shift plant manager an s 'ngineeria d hift eeriag manager to compliment the shift maintenance manager during e startup an durin th tartup and power ascension phase.

The responsibilities of these positions are as follows:

6.1.1 Shift Plaat Manager Thc shift plant manager provides on-shift {24-hour) presence as a direct representative ofthc plant maaager and is responsible for maintaining aa overall perspective ofthe startup pmcess. Ifnecessaty, the shift plant manager is authorized to request operations to delay thc startup, reduce power, or shutdown to make necessary repatrs.

6.1.2 Shift Engineering Manager Thc shift eagiaeering manager provides on-shift (24-hour) presence as a direct representative ofthe plant engineering manager aad is responsible for maintaining an overall perspective ofengineering support ofthc startup process.

The shift engineerin manager willcoatrol on-shift engineering resources as accessary to support scheduled startup testing activities, resolve emergent operability issues, support maintenance aad maaage necessary reactor caginecriag test activities.

6.1.3 Shift Maintenance Manager The shift maiateaancc manalpr provides on-shift (24-hour) presence as a direct tativc ofthe maintenance manager and is responsible for maintaining an overall perspective ofmaintcnaace support ofthe p

repfesca c 0 c startu Th shift aiateaaace manager willcoatrol on-shift maintenance resources as necessary to support scheduled startup testing activities, resolve emergent equipmeat issues, and support operations.

14

This organization willbe implemented as directed by the plant manager at cnncal evolutions during startup such as change to mode 4, initial cri 'ty, and parallel to grid. The organization willbe disbanded as directed by the plant manager but not before mode 4 to 30% power.

6.2 Operating Proficiency and Ezperience Review To minimize the potential for performance errors during the plant startup, the following actions willbe taken:,

operations personnel willutilize the simulator to practice the startup evolution and ensure understanding and proficiency with applicable startup procedures and special requirements; a review of past Cook Nuclear Plant startup issues relevant industry operating experience willbe performed during the functional area r'eviews to ensure understanding ofpast experience and lessons learned; department communication meetings willbe conducted with each plant department to discuss management expectations regarding the startup and power ascension processes, schedule, and responsibilities.

These meetings willbe completed prior to initiating the startup evolution.

15

SYSTEM ENGINEERING REVKW BOARD SERB CHARTER PURPOSE:

Perform a system-based, multi-disciplinary technical review of potential restart issues associated with risk significant plant equipment.

This board willensure consistent application of the restart criteria contained in Attachment C of the Cook Nuclear Plant Restart Plan among system engineers, and ensure that restart decisions reflect the shared concerns of Operations, Maintenance and Engineering.

The result ofthis review willbe to define the equipment related work which is needed to ensure a safe and event free startup and achieve a reliable post startup operating cycle.

MEMBERS:

Director Plant Engineering (Chair)

Mechanical Component Manager Electrical System Manager.

Safety and Analysis Manager IAC Manager Performance Testing Manager Board Secretary Non-Member: Additional attendance by members of Restart Oversight Committee is expected to reinforce expectations and provide oversight'for the restart Issue review process.

Alternate chair:

Site Engineering hfanagers Alternate safety and analysis manager:

Engineers in the Safety and Analysis Section, subject to acceptance ofthe SERB chair or alternate chair.

qUORUM:

Chur(orat a~e), t O

ite M~~~, Se~ and A Vy is M ger(or alternate), and Secretiiry.

16

ACTIONS:

Review all potential restart items identified by System Engineers based on criteria defined in the restart plan; the System Engineer willpresent the ed t

s for discussion.

A representative of Operations and Maintenance knowledgeable of the system's restart issues wi suppo e

system engineer t

engineer and ensure the perspective ofthe other produ'ction groups a

'd ed. The 0 erations representative willnormally be an SS or can be an SS US ofthe Operations crew responsible for the system, but can e an assigned to the Work Control Center.

Designate systems that are required to be presented to the SERB by system engineer, Maintenance and Operations.

The SERB willreview aH items identified as potential restart issues by the system engineer system readiness review. The system engineer, Operations or Maintenance representatives willalso identify other issues which are not identified as potential restart issues but may be questioned.

A complete list ofopen issues on each system willbe available during

'ERB meetings.

Thc SERB willreview and question additional items as desired to determine ifthey should be restart issues.

Ensure a record ofall decisions and concerns raised by the SERB review is documented for future review.

As a result ofthe review, recommend specific potential restart items for approval by the ROC.

Review and approve the charter and any revisions needed to support the restart plan. Disband this board after startup when directed by thc Site Vice President.

D. R. Hafer Direaor ofHact Engneahg 1'7

ATTACHMENTB RE TARTOVERSI HTCOiViGTTEE ROC CHARTER PURPOSE:.

Exercise management oversight and approval of physical and programmatic work scope necessary to ensure a safe and uneventful unit startup, and achieve a reliable operating cycle.

MEMBERS:

Position Plant Manager, Chair Operations Superintendent Vice Chair Production Engineering Director Plant Engineering Director Maintenance Superintendent Licensing Manager Chemistry Superintendent Radiation Protection Superintendent Training Superintendent Restart Manager Restart Plan Project Manager'ecretary'rimary Doug Cooper Bob Gillespie Ken Baker Don Hafer John Boesch Mark Ackerman Dave Morey Doug Noble Dennis Loope John Stubblefield Phil Gora Betty Clark.

Alternate Bob Gillespie Guy Tollas Alberto Verteramo Mike Finissi Mark Stark Gordon Arent Bob Claes Paul Holland Dennis Willemin Dick Strasser Sandy McClintock

'hdicates non-voting member3 QUORUM Chairperson or vice chairperson, and three (3) additional voting members, two of which must be primary members.

Attendance trom Performance Assurance and Business Performance is strongly encouraged to perfotm an active oversight role.

ACTIONS:

Set and communicate expectations for the organization to evaluate work items against the restart scope criteriL.

Ensure screetnng criteria are consistently applied via the restart oversight committee review, meeting and approval process.

18

Some items that meet one or more ofthe criteria may be deferred until aher restart ifthere is special consideration that provides the basis for this decision.

Examples may include items that are only a concern during certain seasons, reduced risk ofperforming the work during a system outage, or implementation ofadequate compensatory actions until a long-term solution is defined. A clear basis for deferral ofthese items is to be provided.

Review and approve:

A.

B.

Restart action items to be completed prior to startup.

Station readiness to initiate until startup and power ascension as determined by the results ofthe assessment of readiness to start up.

4.

Maintain a record ofpresentations, discussions, deliberations and basis for decisions and recommendations.

Review charter as necessary to accommodate changing conditions.

Convene as necessary to accomplish this charter prior to and during startup.

Disband after unit startup when directed by the site vice president.

Site President J/v /97 Date 19

ATTACI.IMENTC ITKRIAFOR WORK IN LUDED IN RESTARTS OPE To be included in the plant restart work scope, items must meet the followingcriteria:

Level 1 Screenin:

Resolves an immediate industrial or nuclear safety issue.

These issues will be mandatory restart items.

~

Necessary to address the voluntary shutdown for the A/E inspection and related programmatic issues.

~

Necessary to address the confirmatory action letter.

Required to return an INOPERABLE system, subsystem or component to OPERABLE status.

o Required to resolve an immediate industrial or nuclear safety concern.

l~d' N

h ai

'd

'6 l

fW WSRei

.Th issues willbe considered for addition to the restart item list based on the review and recommendations ofplant engineering, operations, and maintenance ifthe action:

Eliminates an existing component failure, deficiency, or condition that could result in operation in, or entry to, an LCO action statement.

Resolves existing deficiencies or conditions that:

a.

would result in failure or inabilityto perform a required surveillance test during the current outage or the followingoperating cycle in accordance with the plant technical specifications; b.

would increase the risk to operation for safety associated with performing a surveillance; or c.

would result in the failure to meet a license requirement or a restart commitment to an outside agency.

Restores degraded critical components or conditions that could result in a plant transient, power reduction or shutdown.

Resoh es conditions that have resulted in repetitive safety system or equipment failures.

20

0

Restores licensing b 'ef encies to conforming conditions (extended d scheduled corrective actions may be completed programmauc reviews an post-restart wi e

'th the proper justification of no safety impact, a sa'y ato communication).

OPERABILITYdetermination, and appropriate regulatory corrects equipmen C

ts

'pment with design basis deficiencies; i.e., deficiencies in saf

-related or technical specification equipment not in conformance with

-restart with and scheduled corrective actions may be completed post-restart wi Corrects deficiencies in configuration management programs, processes, en 'ering analysis codes, or operating, maintenance, o'r test procedures (documentation deficiencies, which have no safety impact, may be completed post-restart).

Eli 'es conditions that create a potential for perso nnel radiation Glink oflimits.

exposure, o&ctlvl radioacti 'ty release or e61uent discharge in excess l

0 Reduces cumulative deficiencies, baddogs'or conditions that, m the are evaluated to have significant negative impact on safety, operability or reliable plant operation. (Not applicable to individual work items).

Approved:

w(ZZ 0 z/~kg it Vice President 21

0

ATTACHMENTD

$ELE ON F PLANT$YSTE,'g 120 Vac/CRID Inverters AirRecirculation/Hydrogen Skimmer AuxiliaryFeedvrater 250 Vdc Station Batteries Component Cooling Water Containment Containment Spray Control Air ECCS Accumulators ECCS Charging Modes 1, 2, 3/CVCS Kgh-head Injection ECCS RHR ECCS SI Electrical Safety Busses (4000 V/600 V)

Emergency Diesel Generators Essential Service Water Main Steam Non-essential Service Water Plant AirCompressors Reactor Coolant System/RCS Pressure Relief Reactor Protection Systetn/Solid-state Protection/ESFAS 22

A~ XCHMENTE Restart Process Map (1) Restart Work Scope Determination 1

S Rant Saaescna Solect Plant Syatema For Rovfow Approve Plant Syatoma For Rt)vtow Porfonn Syatam Revlowa S. ~

Add)ttonat Work Scope~

Roqurad?

Perform Readtneaa Aaaoaa ment LS) Rssasssssmasasmsnt J 0 t S2 Yot)date )oaat)ng R Work Scope YES se 6ERS SERB Revtew And Approval Approvo Raatatt Work Scope Addtttone Approved Raatalt Scope Add)tfona S 7 8VS EHOR lsetfotm Work Scope fnsvsfa s'erllxmsnss J2 1

Approved Reatart Work Scope (2 )Restart Work Scope Performance 21 24 MOst)s Plan Roatatt Work Schodule Reatart Work Conduct Reatatt Work Perform Read)ncaa Aaaa aament Ql) Rsssmsaa Aawssmsna i 1 10

~

~

e

~

~

~

'~/~~y

~.

~ ~

//g Fj+~~/g Jj

'I gp'~~/gP ggg ~~+~<.

wh

~~/j/

A7" 'HMENTE Restart Process Map ATTACHMENTE Restart Process Map (4) Restart Authorization (5) Power Operation Perform Fhel Reedheee Revlow Perform FhalR~

Recommend atertup a.s sQrtT Recommend Reetart 4.4 Sec vao &cadent Authorize Restart

~51 Opetsoona Start vp and Power Aacenaron

ATTACHMENT 2 TO AEP:NRC:1260GL COOK NUCLEAR PLANT RESTART PLAN, REVISION 1

APRIL 7, 1998