| issue date = 07/03/1980
| issue date = 07/03/1980
| title = Supplemental Deficiency Rept Re Pacific Check Valves. Problems W/Check Valve Operation in Unit 1 Core Spray Pump Discharge Vertical Pipe Run Will Necessitate Rework of Bonnet Stops.Final Rept Will Be Provided by Sept 1980
| title = Supplemental Deficiency Rept Re Pacific Check Valves. Problems W/Check Valve Operation in Unit 1 Core Spray Pump Discharge Vertical Pipe Run Will Necessitate Rework of Bonnet Stops.Final Rept Will Be Provided by Sept 1980
| author name = CURTIS N W
| author name = Curtis N
| author affiliation = PENNSYLVANIA POWER & LIGHT CO.
| author affiliation = PENNSYLVANIA POWER & LIGHT CO.
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:REGULATOR INFORMATION DISTRIBUTION S TEM (RIDS)AUT~CURT IS g N~'i'I~REC IP~NAME ACCESSION NBRt8007080213 DOC~DATE: 80/07/03 NOTARIZED!
{{#Wiki_filter:REGULATOR     INFORMATION DISTRIBUTION         S   TEM (RIDS)
NO FAC IL: Susquehanna Steam Electric Station<Unit ir Pennsylva Susquehanna Steam Electric Stationr Unit 2i Pennsylva AUTHOR AFFILIATION Pennsylvania Po~er L Light Co, RECIPIENT AFFILIATION DOCKET&#xb9;05000387 05000388
ACCESSION NBRt8007080213                     DOC ~ DATE: 80/07/03 NOTARIZED! NO                   DOCKET  &#xb9; FAC IL:                 Susquehanna     Steam Electric Station< Unit ir Pennsylva               05000387 Susquehanna     Steam Electric Stationr Unit 2i Pennsylva               05000388 AUT ~                          AUTHOR AFFILIATION CURT IS g N ~
                'i'I
                    ~          Pennsylvania Po~er L Light Co, REC IP ~ NAME                  RECIPIENT AFFILIATION


==SUBJECT:==
==SUBJECT:==
Suppl cmental deficiency rept re Paci f ic check valves.Problems w/check valve operation in Unit 1 core spray pump oischarge vertical pipe run will necessitate rework of existing bonnet stops, Final rept will be provided by Sept DISTRIBUTION COOK: 8001S COPIES RECEIVED:1.TR Q ENCL+SIZE: TITLE: PSAR/FSAR AMOTS and Rel ated Cor r'espondence NOTES e SFA/3 RECIPIENT IO CODE/NAME ACTION: AO I-l C8'h/$/A/G.LA RrA<HBRoo]c', W COPIES LTTR ENC 1 1 RECIPIENT L IO CODE/NAME BC ye uNr" Bc.ooo, B.PM SrWZ, 8,.05 COP IKS LTTR ENC INTERNAL: A/D CORE 8 CS13 AUX SYS BR 18 CONT SYS BR OIRr HUM FAC SFY EFF TR SYS BR ENV ENG BR GEOSC IEN BR 09 I8C SYS BR 20 K IRKWOODg R~29 MECH KiNG BR NRC POR 02 POLYER SYS BR QA BR 10 REAC SYS BR SIT ANAL BR 27 1 1 1 1'1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 1 1 ACCID EVAL BR CHEM ENG BR CORE PERF BR 17 DIRECTOR NRR EMERG.PREP 22 EQUIP QUAL BR HYD/GEO BR 11 IEE 06 MATL ENG BR MPA OELO PROC/TST REV BR RAO ASSESS BR12 REG FILE 01 1 1 1 1 1 1 3 1 1 1 1 1 1 EXTERNAL: ACRS NSIC 30 04 10 1 1 LPDR 03 JUL l0 1980 O TOTAL NUMBER OF COPIES REQUIRED: LTTR 51 ENCL TWO NORTH NINTH STREET.ALLENTOWN, PA.18'101 PHONE: (215)821-5151 NORMAN W.CURTIS Vice Prestrtent.Engineering
Suppl cmental               deficiency rept re Paci f ic check valves.
&Construction 821-5381 July 3, 1980 Mr.Boyce H.Grier Director, Region I U.S.Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 SUSQUEHANNA STEAM ELECTRIC STATION UPDATE IN THE STATUS OF A DEFICIENCY ON PACIFIC CHECK VALVES ERs 100450/100508 FILE 840-4/900-10 PLA-502.
Problems w/check valve operation in Unit 1 core spray pump oischarge vertical pipe run will necessitate rework of existing bonnet stops, Final rept will be provided by Sept DISTRIBUTION COOK: 8001S                 COPIES RECEIVED:1.TR     QCorENCL      + SIZE:
TITLE:     PSAR/FSAR AMOTS and Rel ated           r'espondence NOTES e SFA/3 RECIPIENT             COPIES            RECIPIENT                COP IKS IO CODE/NAME              LTTR ENC L        IO CODE/NAME             LTTR ENC ACTION:       AO       I-l C8'h/$ /A/G.       1           BC ye uNr" Bc.ooo, B.
LA RrA<HBRoo]c', W              1            PM SrWZ,   8,. 05 INTERNAL: A/D CORE               8 CS13       1            ACCID EVAL BR                1 AUX SYS BR             18       1      1    CHEM ENG BR                  1 CONT SYS BR                     1'          CORE PERF BR 17              1 OIRr HUM FAC SFY                 1      1    DIRECTOR NRR                1 EFF TR SYS BR                   1      1    EMERG.PREP          22      1 ENV ENG BR                       1      1    EQUIP QUAL BR                1 GEOSC IEN BR           09       4            HYD/GEO BR          11 I8C SYS BR             20       1      1    IEE                06      3 K IRKWOODg R ~         29       1      1    MATL ENG BR                  1 MECH KiNG BR                     1            MPA                          1 NRC       POR         02       1            OELO                        1 POLYER       SYS BR             1           PROC/TST REV BR             1 QA BR                  10      1            RAO ASSESS BR12 REAC SYS BR                      1            REG   FILE         01       1 SIT ANAL          BR  27      1                                         1 EXTERNAL: ACRS                       30     10     1     LPDR               03 NSIC                    04      1 JUL l0 1980 O
TOTAL NUMBER OF COPIES                 REQUIRED: LTTR     51   ENCL
 
TWO NORTH NINTH STREET. ALLENTOWN, PA. 18'101 PHONE: (215) 821-5151 NORMAN W. CURTIS Vice Prestrtent.Engineering & Construction 821-5381 July 3, 1980 Mr. Boyce H. Grier Director, Region             I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 SUSQUEHANNA STEAM ELECTRIC STATION UPDATE IN THE STATUS OF A DEFICIENCY ON PACIFIC CHECK VALVES ERs     100450/100508           FILE 840-4/900-10 PLA-502.


==Reference:==
==Reference:==
PLA-466  of March 31, 1980
==Dear Mr.        Grier:==


PLA-466 of March 31, 1980  
This supplements the above referenced correspondence and provides an update of the information provided in our PLA-466.
Unanticipated problems with check valve operation in the Unit I Core Spray pump discharge vertical pipe run will necessitate rework of the existing bonnet stops. Bechtel NCR 5913 documents this latest discrepancy.
The original problem remains open under MCAR 1-47.
We    expect to provide a        final report to    the Commission by September,   1980.
Very      truly yours, N. W.      Curtis Vice President-Engineering            a  Construction<<Nuclear FLWsjmk Ps,a PENNSYLVANIA POWER  IL  LIGHT COMPANY 8 OOV080 zi9


==Dear Mr.Grier:==
Mr. Boyce H. Grier                                       June 27, 1980 cc: Mr. Victor Stello (15) copies DirectorWffice of Inspection 8   Enforcement.
This supplements the above referenced correspondence and provides an update of the information provided in our PLA-466.Unanticipated problems with check valve operation in the Unit I Core Spray pump discharge vertical pipe run will necessitate rework of the existing bonnet stops.Bechtel NCR 5913 documents this latest discrepancy.
U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. G. McDonald, Director (1)
The original problem remains open under MCAR 1-47.We expect to provide a final report to the Commission by September, 1980.Very truly yours, N.W.Curtis Vice President-Engineering a Construction<<Nuclear FLWsjmk Ps,a PENNSYLVANIA POWER IL LIGHT COMPANY 8 OOV080 zi9 Mr.Boyce H.Grier June 27, 1980 cc: Mr.Victor Stello (15)copies DirectorWffice of Inspection 8 Enforcement.
Office of Management Information & Program Control U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. Robert,,M. Gallo U. S. Nuclear Regulatory Commission P. O. Box 52 Shickshinny, Pennsylvania 1S655}}
U.S.Nuclear Regulatory Commission Washington, D.C.20555 Mr.G.McDonald, Director (1)Office of Management Information
&Program Control U.S.Nuclear Regulatory Commission Washington, D.C.20555 Mr.Robert,,M.
Gallo U.S.Nuclear Regulatory Commission P.O.Box 52 Shickshinny, Pennsylvania 1S655}}

Latest revision as of 01:47, 22 October 2019

Supplemental Deficiency Rept Re Pacific Check Valves. Problems W/Check Valve Operation in Unit 1 Core Spray Pump Discharge Vertical Pipe Run Will Necessitate Rework of Bonnet Stops.Final Rept Will Be Provided by Sept 1980
ML18030A123
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 07/03/1980
From: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
To:
References
PLA-502, NUDOCS 8007080213
Download: ML18030A123 (3)


Text

REGULATOR INFORMATION DISTRIBUTION S TEM (RIDS)

ACCESSION NBRt8007080213 DOC ~ DATE: 80/07/03 NOTARIZED! NO DOCKET ¹ FAC IL: Susquehanna Steam Electric Station< Unit ir Pennsylva 05000387 Susquehanna Steam Electric Stationr Unit 2i Pennsylva 05000388 AUT ~ AUTHOR AFFILIATION CURT IS g N ~

'i'I

~ Pennsylvania Po~er L Light Co, REC IP ~ NAME RECIPIENT AFFILIATION

SUBJECT:

Suppl cmental deficiency rept re Paci f ic check valves.

Problems w/check valve operation in Unit 1 core spray pump oischarge vertical pipe run will necessitate rework of existing bonnet stops, Final rept will be provided by Sept DISTRIBUTION COOK: 8001S COPIES RECEIVED:1.TR QCorENCL + SIZE:

TITLE: PSAR/FSAR AMOTS and Rel ated r'espondence NOTES e SFA/3 RECIPIENT COPIES RECIPIENT COP IKS IO CODE/NAME LTTR ENC L IO CODE/NAME LTTR ENC ACTION: AO I-l C8'h/$ /A/G. 1 BC ye uNr" Bc.ooo, B.

LA RrA<HBRoo]c', W 1 PM SrWZ, 8,. 05 INTERNAL: A/D CORE 8 CS13 1 ACCID EVAL BR 1 AUX SYS BR 18 1 1 CHEM ENG BR 1 CONT SYS BR 1' CORE PERF BR 17 1 OIRr HUM FAC SFY 1 1 DIRECTOR NRR 1 EFF TR SYS BR 1 1 EMERG.PREP 22 1 ENV ENG BR 1 1 EQUIP QUAL BR 1 GEOSC IEN BR 09 4 HYD/GEO BR 11 I8C SYS BR 20 1 1 IEE 06 3 K IRKWOODg R ~ 29 1 1 MATL ENG BR 1 MECH KiNG BR 1 MPA 1 NRC POR 02 1 OELO 1 POLYER SYS BR 1 PROC/TST REV BR 1 QA BR 10 1 RAO ASSESS BR12 REAC SYS BR 1 REG FILE 01 1 SIT ANAL BR 27 1 1 EXTERNAL: ACRS 30 10 1 LPDR 03 NSIC 04 1 JUL l0 1980 O

TOTAL NUMBER OF COPIES REQUIRED: LTTR 51 ENCL

TWO NORTH NINTH STREET. ALLENTOWN, PA. 18'101 PHONE: (215) 821-5151 NORMAN W. CURTIS Vice Prestrtent.Engineering & Construction 821-5381 July 3, 1980 Mr. Boyce H. Grier Director, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 SUSQUEHANNA STEAM ELECTRIC STATION UPDATE IN THE STATUS OF A DEFICIENCY ON PACIFIC CHECK VALVES ERs 100450/100508 FILE 840-4/900-10 PLA-502.

Reference:

PLA-466 of March 31, 1980

Dear Mr. Grier:

This supplements the above referenced correspondence and provides an update of the information provided in our PLA-466.

Unanticipated problems with check valve operation in the Unit I Core Spray pump discharge vertical pipe run will necessitate rework of the existing bonnet stops. Bechtel NCR 5913 documents this latest discrepancy.

The original problem remains open under MCAR 1-47.

We expect to provide a final report to the Commission by September, 1980.

Very truly yours, N. W. Curtis Vice President-Engineering a Construction<<Nuclear FLWsjmk Ps,a PENNSYLVANIA POWER IL LIGHT COMPANY 8 OOV080 zi9

Mr. Boyce H. Grier June 27, 1980 cc: Mr. Victor Stello (15) copies DirectorWffice of Inspection 8 Enforcement.

U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. G. McDonald, Director (1)

Office of Management Information & Program Control U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. Robert,,M. Gallo U. S. Nuclear Regulatory Commission P. O. Box 52 Shickshinny, Pennsylvania 1S655