ML063400431: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 2: Line 2:
| number = ML063400431
| number = ML063400431
| issue date = 11/06/2006
| issue date = 11/06/2006
| title = Haddam Neck Plant, Final Status Survey Final Report Phase Iv, Appendix A2, Survey Unit Release Record 9106-0002, Discharge Canal
| title = Final Status Survey Final Report Phase IV, Appendix A2, Survey Unit Release Record 9106-0002, Discharge Canal
| author name = Newson C
| author name = Newson C
| author affiliation = Connecticut Yankee Atomic Power Co
| author affiliation = Connecticut Yankee Atomic Power Co
Line 61: Line 61:
'i Base Case Soil 0perational DCGL Rqie lD H-3 DCGL (pCi/g) (2) wK(pC i/ 1 (3)() (PCi/gj) (4)H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+O1 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+O1 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+0I Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
'i Base Case Soil 0perational DCGL Rqie lD H-3 DCGL (pCi/g) (2) wK(pC i/ 1 (3)() (PCi/gj) (4)H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+O1 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+O1 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+0I Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Characterization was performed in April and May of 2004 as discussed in Section 2. Cesium-137, Cobalt-60 and Strontium-90 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median)for Cs-137, Co-60 and Sr-90 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration  
Characterization was performed in April and May of 2004 as discussed in Section 2. Cesium-137, Cobalt-60 and Strontium-90 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median)for Cs-137, Co-60 and Sr-90 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration
(<MDC) were not accepted for FSS. Sample report Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined.
(<MDC) were not accepted for FSS. Sample report Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined.
Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established.
Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established.
Line 134: Line 134:
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major rLI Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn 4.Priority:
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major rLI Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn 4.Priority:
Z 30 D. E] 14 D. L] 7 D. Container Sample Size- ,dq Z Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-001Fe 5/17/06 10:42 SE C BP X X Transferred from COC 2006-00357 9106-0002-002F 5/18/06 09:43 SE C BP X Transferred from COC 2006-00361 9106-0002-003F&
Z 30 D. E] 14 D. L] 7 D. Container Sample Size- ,dq Z Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-001Fe 5/17/06 10:42 SE C BP X X Transferred from COC 2006-00357 9106-0002-002F 5/18/06 09:43 SE C BP X Transferred from COC 2006-00361 9106-0002-003F&
5/18/06 10:14 SE C BP X X Transferred from COC 2006-003 61 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F' 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP X x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP X X Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal o- 55 Z Fed Ex Container El UPS Temp.: CajLa 0-b-~ r~lo ( 6A ~ Deg. C Cj- o .;l Hand Custody Sealed?Rel qu By Date/Time  
5/18/06 10:14 SE C BP X X Transferred from COC 2006-003 61 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F' 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP X x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP X X Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal o- 55 Z Fed Ex Container El UPS Temp.: CajLa 0-b-~ r~lo ( 6A ~ Deg. C Cj- o .;l Hand Custody Sealed?Rel qu By Date/Time
: 2) .ived By Date/Time Custody Seal M ;"-aO LI Other Intact?I)Telinqtuished 9 Date/Time  
: 2) .ived By Date/Time Custody Seal M ;"-aO LI Other Intact?I)Telinqtuished 9 Date/Time
: 4) Received By Date/Time YO NO Bill of Lading #5) Relinquished By Date/Time  
: 4) Received By Date/Time YO NO Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 7'09 9/16 .7/0 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major ON~Chain of Custody FormNo206037 Connecticut Yankee Atomic Power Company No. 2006-00372 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 <843 556 8171. Attn. Cheryl Jones L C , Priority:
: 6) Received By Date/Time 7'09 9/16 .7/0 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major ON~Chain of Custody FormNo206037 Connecticut Yankee Atomic Power Company No. 2006-00372 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 <843 556 8171. Attn. Cheryl Jones L C , Priority:
E 30 D. F] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-011 F 5/19/06 08:10 SE C BP X X Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-014FSjo 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal 0755 [ Fed Ex Container El UPS Temp.:* '-~c% A +iuA*L1 4 1 0ovt4v'; O~e4- C b i$/&Deg. C El,.u Hand Custody Sealed?1 n Date/Time  
E 30 D. F] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-011 F 5/19/06 08:10 SE C BP X X Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-014FSjo 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal 0755 [ Fed Ex Container El UPS Temp.:* '-~c% A +iuA*L1 4 1 0ovt4v'; O~e4- C b i$/&Deg. C El,.u Hand Custody Sealed?1 n Date/Time
: 2) ReMved By Dat Time Custody Seal , ( El Other Intact?3)x(elinquished By Date/Time  
: 2) ReMved By Dat Time Custody Seal , ( El Other Intact?3)x(elinquished By Date/Time
: 4) Received By Date/Time BillofLdin9Y E N E Bill of Lading B 5) Relinquished By Date/Time  
: 4) Received By Date/Time BillofLdin9Y E N E Bill of Lading B 5) Relinquished By Date/Time
: 6) Received By Date/Time 7'qoq z/Y'*" z57 1~c1 Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received: -, ')V 2 9Q SDG#: Work Order Number:-.  
: 6) Received By Date/Time 7'qoq z/Y'*" z57 1~c1 Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received: -, ')V 2 9Q SDG#: Work Order Number:-.  
.L 2-" Shipping Cdntainer ID] P(O Y!L,5I2/4' Chain of Custody # 4 cQ" 7!1. Custody Seals ori shipping container intact?.. -Yes No[ ]2. Custody Seals dated and signed? Yes JN [No ].3. Chain-of-Custody record present? Yes ,TNo ]4. Cooler temperature
.L 2-" Shipping Cdntainer ID] P(O Y!L,5I2/4' Chain of Custody # 4 cQ" 7!1. Custody Seals ori shipping container intact?.. -Yes No[ ]2. Custody Seals dated and signed? Yes JN [No ].3. Chain-of-Custody record present? Yes ,TNo ]4. Cooler temperature
Line 162: Line 162:
Yes [ No 8. Samples have:-tape ___hazard labels-Custody seals appropriate sample labels 9. Samples are.'.. in good condition -leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No -11. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:
Yes [ No 8. Samples have:-tape ___hazard labels-Custody seals appropriate sample labels 9. Samples are.'.. in good condition -leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No -11. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:
f; .Date.: 6 "o "" Telephoned to: On .y -" 9  
f; .Date.: 6 "o "" Telephoned to: On .y -" 9  
-SAMPLE RECEIPT & REVIEW FORM 0 PM use only CI Cie-Tnt: ecF1L f (0( ec SDG/ARCOCi'Werk Order: &C-'yozo Date Received:  
-SAMPLE RECEIPT & REVIEW FORM 0 PM use only CI Cie-Tnt: ecF1L f (0( ec SDG/ARCOCi'Werk Order: &C-'yozo Date Received:
[ o PM(A) Review ( re non-conro ug i are reoved prior to signing): Received By:I Sample Receipt Criteria Comments/Qualifiers equired for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:
[ o PM(A) Review ( re non-conro ug i are reoved prior to signing): Received By:I Sample Receipt Criteria Comments/Qualifiers equired for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:
seals broke damaged container leaking container other (describe) and sealed? 1 7 Samples requiring cold Circle Coolant # ic ags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?4 Sample containers intact and Cird Applicable:
seals broke damaged container leaking container other (describe) and sealed? 1 7 Samples requiring cold Circle Coolant # ic ags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?4 Sample containers intact and Cird Applicable:
Line 408: Line 408:
-2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c .Priority:
-2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c .Priority:
Z 30 D. [] 14 D. [: 7 D. Container Sample Size- -. ;, Media Type &Type Lab ID Sample Designation Date Time Code Code Code Comment, Preservation Lab SampleID 9106-0002-017F 6/2/06 12:49 SE C BP x X Transferred from COC 2006-00378 9106-0002-018F 6/2/06 13:15 SE C BP X X Transferred f-rom COC 2006-00378 9106-0002-018FS 6/2/06 13:15 SE C BP X x Transferred from COC 2006-00378 9106-0002-019F 6/2/06 13:45 SE C BP X X Transferred from COC 2006-00378 NOTES: PO #: 002332 MSR #: 06- 01/ISSWP#
Z 30 D. [] 14 D. [: 7 D. Container Sample Size- -. ;, Media Type &Type Lab ID Sample Designation Date Time Code Code Code Comment, Preservation Lab SampleID 9106-0002-017F 6/2/06 12:49 SE C BP x X Transferred from COC 2006-00378 9106-0002-018F 6/2/06 13:15 SE C BP X X Transferred f-rom COC 2006-00378 9106-0002-018FS 6/2/06 13:15 SE C BP X x Transferred from COC 2006-00378 9106-0002-019F 6/2/06 13:45 SE C BP X X Transferred from COC 2006-00378 NOTES: PO #: 002332 MSR #: 06- 01/ISSWP#
NA Z LTP QA R] Radwaste QA [I Non QA Samples Shipped Via: :Ilnt a[ Fed Ex El UPS ... .em) '.Deg. C E] Hand &#xfd;4Custody Sealed?YFn N D 1) Relinquished By Date/Time  
NA Z LTP QA R] Radwaste QA [I Non QA Samples Shipped Via: :Ilnt a[ Fed Ex El UPS ... .em) '.Deg. C E] Hand &#xfd;4Custody Sealed?YFn N D 1) Relinquished By Date/Time
: 2) R d Date/Time o is dySealr,.&#xfd;.D y -o Other :.Intaet .3) Relinquished By Date/Time  
: 2) R d Date/Time o is dySealr,.&#xfd;.D y -o Other :.Intaet .3) Relinquished By Date/Time
: 4) Received by Date/Time  
: 4) Received by Date/Time  
;__y.__ .-N D Bill of Lading #5) Relinquished By Date/Time  
;__y.__ .-N D Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time71  
: 6) Received By Date/Time71  
/ J 3-r " .. -6)IIW .Receive B rJ 63)A-1  
/ J 3-r " .. -6)IIW .Receive B rJ 63)A-1  
Line 512: Line 512:
)106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365
)106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365
)106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 WOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA fl Non QA Samples Shipped Via: Internal 0 '755 Z Fed Ex Container 4 _Mcvv+ 4t 1  o.'aY, e Yb i0/k/ Da UPS Temp.: C tLaCE L Hand Custody I DyL Sealed?u~he Date/Time  
)106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 WOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA fl Non QA Samples Shipped Via: Internal 0 '755 Z Fed Ex Container 4 _Mcvv+ 4t 1  o.'aY, e Yb i0/k/ Da UPS Temp.: C tLaCE L Hand Custody I DyL Sealed?u~he Date/Time  
..2) Reived By Datj&#xfd;Time Custody Seal , /% "- C4(,. [J Other Intact?1) '1elinquished By Date/Time  
..2) Reived By Datj&#xfd;Time Custody Seal , /% "- C4(,. [J Other Intact?1) '1elinquished By Date/Time
: 4) ReceivedBy Date/Time  
: 4) ReceivedBy Date/Time  
'Y.___"0_.___
'Y.___"0_.___
Y-.N N-.__ _*_.__ _ _ Bill of Lading #) Relinquished By Date/Time  
Y-.N N-.__ _*_.__ _ _ Bill of Lading #) Relinquished By Date/Time
: 6) Received By Date/Time 7O ''7 // & t Connect~cut Yankee.Statement of Work for Analytical Lab Services _ ' .. " CY-iSC-Sow-001 Figure 1. Sample Check-in List.Date/Time pRectivedz, 0 (-SDG #: Work Order Number_ (LP.Shipping Custainer d,'hipinC Cut3q .1 Custody Seats orshipping container intact? "Yes No 2. Custody Seals dated and signed? Yes N.o .3. Chain-of-Custo,,y record present? Ye '~s/ No [ ]* 4. Cooler emperature
: 6) Received By Date/Time 7O ''7 // & t Connect~cut Yankee.Statement of Work for Analytical Lab Services _ ' .. " CY-iSC-Sow-001 Figure 1. Sample Check-in List.Date/Time pRectivedz, 0 (-SDG #: Work Order Number_ (LP.Shipping Custainer d,'hipinC Cut3q .1 Custody Seats orshipping container intact? "Yes No 2. Custody Seals dated and signed? Yes N.o .3. Chain-of-Custo,,y record present? Ye '~s/ No [ ]* 4. Cooler emperature
: 5. Vermiculite/packing materials is: Wet [ Dry', 0 t  6.' Number of samples in shipping container: " -.-7. Sample. holding times exceeded?
: 5. Vermiculite/packing materials is: Wet [ Dry', 0 t  6.' Number of samples in shipping container: " -.-7. Sample. holding times exceeded?
Y No 8. S I hav""&#xfd;]L ap h-a" -- .''' zr labels.custody " -appropriate sample labels 9. Sarmples are.good condition  
Y No 8. S I hav""&#xfd;]L ap h-a" -- .''' zr labels.custody " -appropriate sample labels 9. Sarmples are.good condition  
.l....eaking'-broken -*.....have air bubbles 10. Were any anomalies identified in sample receipt? .Yes [No 9"j*.... .Description of anomalies (include sample numbers):
.l....eaking'-broken -*.....have air bubbles 10. Were any anomalies identified in sample receipt? .Yes [No 9"j*.... .Description of anomalies (include sample numbers):
_ _"_._, S Sample Custodian/Laboratory:.  
_ _"_._, S Sample Custodian/Laboratory:.
: 4.0Dt'Telephoned to: On By .."~~~- B .-."' *""". -  
: 4.0Dt'Telephoned to: On By .."~~~- B .-."' *""". -  
*SAMPLE RECEIPT & REVIEW FORM"PM use only., ,J n -/" Y ,Client: C r c(4c YA RG C- SDGIARCOC-Work Order: (OZO Date Received:  
*SAMPLE RECEIPT & REVIEW FORM"PM use only., ,J n -/" Y ,Client: C r c(4c YA RG C- SDGIARCOC-Work Order: (OZO Date Received:
(,a C$&#xfd;o PM(A) Review (ere non-&#xfd;confo ng i rns are resolved prior to signing);
(,a C$&#xfd;o PM(A) Review (ere non-&#xfd;confo ng i rns are resolved prior to signing);
j Received By:j Sample Receipt Criteria Comments/Qualitiers  
j Received By:j Sample Receipt Criteria Comments/Qualitiers  
Line 646: Line 646:
base64 Page 4 of 105 IloflI 8/2/2006 7:04 PM flnne Tn be done Done To be done Previous GEL ID ICY samnie location IDs FSS Gain Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 C164220008 9106-0002-007F x x x x x x x x x x o 164220012 9106-0002-011F x _ x x x x x x x x x 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832001 9106-0004-015F x x x x x x x x x x 162485001 9106-0005-010F x x x x x x x x x x 162485011 9106-0005-014F x x x x x x x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 91060010-001 F x x x x x x x x x x 163105016 9106-0010-012F x x x x x x x x x x Chain of Custody and Supporting Documentation Page 6 of 105 kvlaj Health Physics Procedure ffe !K Iq 1) 1&#xfd;GPP-GGGR-R5 1 04-003-Attachment B-CY-001 Major Chain of Custody NoForm007 Connecticut Yankee Atomic Power Company No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556  
base64 Page 4 of 105 IloflI 8/2/2006 7:04 PM flnne Tn be done Done To be done Previous GEL ID ICY samnie location IDs FSS Gain Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 C164220008 9106-0002-007F x x x x x x x x x x o 164220012 9106-0002-011F x _ x x x x x x x x x 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832001 9106-0004-015F x x x x x x x x x x 162485001 9106-0005-010F x x x x x x x x x x 162485011 9106-0005-014F x x x x x x x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 91060010-001 F x x x x x x x x x x 163105016 9106-0010-012F x x x x x x x x x x Chain of Custody and Supporting Documentation Page 6 of 105 kvlaj Health Physics Procedure ffe !K Iq 1) 1&#xfd;GPP-GGGR-R5 1 04-003-Attachment B-CY-001 Major Chain of Custody NoForm007 Connecticut Yankee Atomic Power Company No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556  
.....cProject Name: Haddarn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 a 843 556 8171. Attn. Cheryl Jones C U , Priority:
.....cProject Name: Haddarn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 a 843 556 8171. Attn. Cheryl Jones C U , Priority:
Z 30 D. [] 14 D. [-] 7 D. Container 1 40 .A Sample Size- ,_ _Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OO1F 5/17/06 10:42 SE C BP x x Transferred from COC 2006-0o357 9106-0002-002F 5/18/06 09:43 SE C BP x Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP x x Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP x x Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x -'Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X X _ _ Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x x Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP x x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 114:04 SE C BP "x x Transferred from COC 2006-00364 NOTES: P0 #: 002332 MSR #: 06- SSWP# NA [K LTP QA El Radwaste QA E3 Non QA Samples Shipped Via: Internal r 5 Fed Ex Container El UPS Temp.: Deg. C fl Hand Custody Sealed?IRehi -Date/Time  
Z 30 D. [] 14 D. [-] 7 D. Container 1 40 .A Sample Size- ,_ _Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OO1F 5/17/06 10:42 SE C BP x x Transferred from COC 2006-0o357 9106-0002-002F 5/18/06 09:43 SE C BP x Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP x x Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP x x Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x -'Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X X _ _ Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x x Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP x x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 114:04 SE C BP "x x Transferred from COC 2006-00364 NOTES: P0 #: 002332 MSR #: 06- SSWP# NA [K LTP QA El Radwaste QA E3 Non QA Samples Shipped Via: Internal r 5 Fed Ex Container El UPS Temp.: Deg. C fl Hand Custody Sealed?IRehi -Date/Time
: 2) 1&#xfd; ived By Date/Time Custody Seal e-& --"&#xfd;4 ( C\'.;O EOthler Intact?&#xfd;&#xfd;Ielinquished B Date/Time  
: 2) 1&#xfd; ived By Date/Time Custody Seal e-& --"&#xfd;4 ( C\'.;O EOthler Intact?&#xfd;&#xfd;Ielinquished B Date/Time
: 4) Received By Date/Time BillofLading
: 4) Received By Date/Time BillofLading
___Y 11 N O Bill of Lading R 5) Relinquished By Date/Time  
___Y 11 N O Bill of Lading R 5) Relinquished By Date/Time
: 6) Received By Date/Time I 17J I Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Healt Phyics roceure PP-GGR-R 10-0 AtahetBCY0 a CD 00 Chain of Custody Form No. 2006-00372 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 5 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: 'Comments:
: 6) Received By Date/Time I 17J I Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Healt Phyics roceure PP-GGR-R 10-0 AtahetBCY0 a CD 00 Chain of Custody Form No. 2006-00372 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 5 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: 'Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) General Engineeriag Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones rn Priority:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) General Engineeriag Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones rn Priority:
S] 30 D. [1 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Tr-n-e-e-Comment, Preservation Lab Sample I2 9106-0002-009F 5/18/06 14:28 SE C BP XTrsfrefomC 20-06 9106-0002-00F 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-01IF 5/19/06 08:10 SE C BP x x -Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X X Transferred frorn-COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X -Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:89 SE C BP x X -Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 NOTES: PO # 002332 MSR #: 06- SSWP# NA Z LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal , Fed Ex Container 0 UPS Temp.: __Deg. C LI Hand Custody Sealed?1 Relin ish Date/Time  
S] 30 D. [1 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Tr-n-e-e-Comment, Preservation Lab Sample I2 9106-0002-009F 5/18/06 14:28 SE C BP XTrsfrefomC 20-06 9106-0002-00F 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-01IF 5/19/06 08:10 SE C BP x x -Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X X Transferred frorn-COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X -Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:89 SE C BP x X -Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 NOTES: PO # 002332 MSR #: 06- SSWP# NA Z LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal , Fed Ex Container 0 UPS Temp.: __Deg. C LI Hand Custody Sealed?1 Relin ish Date/Time
: 2) Re ived By ime Custody Seal COther Intact?3)"Kelinquished By Date/Time  
: 2) Re ived By ime Custody Seal COther Intact?3)"Kelinquished By Date/Time
: 4) Received By Date/Time
: 4) Received By Date/Time
_ _ _ _ NO Bill of Lading I 5) Relinquished By Date/Time  
_ _ _ _ NO Bill of Lading I 5) Relinquished By Date/Time
: 6) Received By Date/Time 7qo0 J c Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received:  
: 6) Received By Date/Time 7qo0 J c Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received:
(0 "? .( g  SDG#: c)- 0 -C -" Work Order Number: L L17z( ".Shipping C ,,,tainer IDT, 196_5S /O Chain of Custody*# '() 4, c .') /1. Custody Seals oti shipping container intact?., Yes No[]2. Custody Seals dated and signed? Yes No[]3. Chain-of-Custody record present? Yes No [].4. Cooler temperature  
(0 "? .( g  SDG#: c)- 0 -C -" Work Order Number: L L17z( ".Shipping C ,,,tainer IDT, 196_5S /O Chain of Custody*# '() 4, c .') /1. Custody Seals oti shipping container intact?., Yes No[]2. Custody Seals dated and signed? Yes No[]3. Chain-of-Custody record present? Yes No [].4. Cooler temperature  
" 5. Verniculite/packing materials is: Wet [ Dry [A 0] (0.Number of samples in shipping container:
" 5. Verniculite/packing materials is: Wet [ Dry [A 0] (0.Number of samples in shipping container:
Line 695: Line 695:
E Fed Ex !Tetpi*..:::  
E Fed Ex !Tetpi*..:::  
'..DegeC E] U PS  
'..DegeC E] U PS  
.' ..,.": 0I Hand Custody Sealed 9.1) Relinquished By Date/Time  
.' ..,.": 0I Hand Custody Sealed 9.1) Relinquished By Date/Time
: 2) -ived By _ t ie*isoySa nat/-______________.__,_y_--______.330 , f1 Other 3) Relinquished By Date/Time  
: 2) -ived By _ t ie*isoySa nat/-______________.__,_y_--______.330 , f1 Other 3) Relinquished By Date/Time
: 4) Received By Da/Time _______________Y  
: 4) Received By Da/Time _______________Y
:l N -Bill of Lading .5) Relinquished By Date/Time  
:l N -Bill of Lading .5) Relinquished By Date/Time
: 6) Received By Date/Time  
: 6) Received By Date/Time  
.92O- 9,,O-O2 4 "
.92O- 9,,O-O2 4 "
Line 706: Line 706:
-.,,. ..toAi 9106-0003-009F 4/25/06 13:00 SE C BP X -Transferred from COC 2006-00236  
-.,,. ..toAi 9106-0003-009F 4/25/06 13:00 SE C BP X -Transferred from COC 2006-00236  
'. ..0A 9106-0003-010F 4/25/06 13:23 SE C BP X TransferredfromCOC2006-00236 0 9106-0003-O1OFS 4/25/06 13:23 SE C BP x Transferred from COC 2006-00236 9106-0003-012F 4/25/06 15:12 SE C BP x Transferred from COC 2006-00236 S9106-0003-012F 4/25/06 14:121 SE C BP x- -Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP X Transferred from COC 2006-00236 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred from COC 2006-00236 OR 9106-0003-015F 4/26/06 08:16 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP x Transferred from COC 2006-00237
'. ..0A 9106-0003-010F 4/25/06 13:23 SE C BP X TransferredfromCOC2006-00236 0 9106-0003-O1OFS 4/25/06 13:23 SE C BP x Transferred from COC 2006-00236 9106-0003-012F 4/25/06 15:12 SE C BP x Transferred from COC 2006-00236 S9106-0003-012F 4/25/06 14:121 SE C BP x- -Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP X Transferred from COC 2006-00236 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred from COC 2006-00236 OR 9106-0003-015F 4/26/06 08:16 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP x Transferred from COC 2006-00237
-9106-0003-018F 4/26/06 08:59 SE C BP X Transferred from COC 2006-00237 .J "'Y. , NOTES: PO #: 002332 MSR #: 06- Os SSWP#NA 0 LTP QA[I Radwaste QA[] Non QA 1) Relinquished By Date/Time  
-9106-0003-018F 4/26/06 08:59 SE C BP X Transferred from COC 2006-00237 .J "'Y. , NOTES: PO #: 002332 MSR #: 06- Os SSWP#NA 0 LTP QA[I Radwaste QA[] Non QA 1) Relinquished By Date/Time
: 2) fReceived By D Date//Time
: 2) fReceived By D Date//Time
: 3) Relinquished By Date/Time  
: 3) Relinquished By Date/Time
: 4) Received By rDaC/Time Samples Shipped Via: Z Fed Ex El uPs El Hand El Other Bill of Lading #75120-Z'1-20/-
: 4) Received By rDaC/Time Samples Shipped Via: Z Fed Ex El uPs El Hand El Other Bill of Lading #75120-Z'1-20/-
o2,d..T~eer 4De C!N'yso 6 Jd?.b'td~_J;I; Y-t~4N ux,." /Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:
o2,d..T~eer 4De C!N'yso 6 Jd?.b'td~_J;I; Y-t~4N ux,." /Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:
t (.0I SDG#: j46j 'Work Order Number: .I tceZ-3 Shipping cdntainer ID: "-l wqlf 'zi ) 0_7Ci f IChain of Custody# ( )(Yo 003'i 1. Custody Seals off shipping container intact?. Yes t ] No 2. Custody Seals dated and signed7 Yes [ ' No 3. Chain-of-Custody record present? Yes No [].4. Cooler temperature C 1 I C.-5. Vermiculite/packing materials is: 'et [ Dry [ n] '__-_!__:_
t (.0I SDG#: j46j 'Work Order Number: .I tceZ-3 Shipping cdntainer ID: "-l wqlf 'zi ) 0_7Ci f IChain of Custody# ( )(Yo 003'i 1. Custody Seals off shipping container intact?. Yes t ] No 2. Custody Seals dated and signed7 Yes [ ' No 3. Chain-of-Custody record present? Yes No [].4. Cooler temperature C 1 I C.-5. Vermiculite/packing materials is: 'et [ Dry [ n] '__-_!__:_
6.' Number of samples in shipping container:  
6.' Number of samples in shipping container:
[t e- Ea t[ 7 r'- ri L 7. Sample holding times exceeded?
[t e- Ea t[ 7 r'- ri L 7. Sample holding times exceeded?
Yes [ I No.8. Sampleh :'tae -hazard labelscustody seals -appropriate sample labels 9. Samples are-good condition jleaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No I.. =Description of anomalies (include sample numbers):.amnple.Custodian/Laboratory: ( ,f>( &'. cc'C. -Telephoned to: On By Page 15 of 105 SAMLERECEIPT  
Yes [ I No.8. Sampleh :'tae -hazard labelscustody seals -appropriate sample labels 9. Samples are-good condition jleaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No I.. =Description of anomalies (include sample numbers):.amnple.Custodian/Laboratory: ( ,f>( &'. cc'C. -Telephoned to: On By Page 15 of 105 SAMLERECEIPT  
Line 749: Line 749:
_ _ _ _ _. ....8 Samples received within holding Id'S and tMtS aected: time?9 Sample ID's on COC match ID's Sp ID's and conins affected: on bottles?Date & time on COC match date Sm ID's affected:& time on bottles? _Number of containers received S amte D's affcted: 11 match number indicated on COC?12 COC form is properly signed in relinfqushed/received sections?
_ _ _ _ _. ....8 Samples received within holding Id'S and tMtS aected: time?9 Sample ID's on COC match ID's Sp ID's and conins affected: on bottles?Date & time on COC match date Sm ID's affected:& time on bottles? _Number of containers received S amte D's affcted: 11 match number indicated on COC?12 COC form is properly signed in relinfqushed/received sections?
__ C-. A-* 4 -" 6,#.,S 6&14 Air Bill ,Tracking  
__ C-. A-* 4 -" 6,#.,S 6&14 Air Bill ,Tracking  
#'s, &Additional Comments..RADI Receipt-4 ; gj*If > x2. area background is obsered on samples identifiedason s ed r Inormation ulated/non-radioactive, contact the Radiation Safety group for'further A Radiological Clamific~tion?  
#'s, &Additional Comments..RADI Receipt-4 ; gj*If > x2. area background is obsered on samples identifiedason s ed r Inormation ulated/non-radioactive, contact the Radiation Safety group for'further A Radiological Clamific~tion?
:________________Maximum Counts Obseved*:  
:________________Maximum Counts Obseved*:  
<n IPCB Reglate-?:  
<n IPCB Reglate-?:  
Line 793: Line 793:
&#xfd;froject Name: Haddam Neck Decommissioning  
&#xfd;froject Name: Haddam Neck Decommissioning  
-Analyses Requested MI .&#xfd;Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 K, Analytical Lab (Name, City, State) .General Engineering Laboratories  
-Analyses Requested MI .&#xfd;Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 K, Analytical Lab (Name, City, State) .General Engineering Laboratories  
.4 2040 Savage Road. Charleston SC. 29407 '843 556 8171. Attn. Cheryl Jones cn Cn Priority:  
.4 2040 Savage Road. Charleston SC. 29407 '843 556 8171. Attn. Cheryl Jones cn Cn Priority:
[ 30 D. [ 14 D. [ 7 D. Container  
[ 30 D. [ 14 D. [ 7 D. Container  
-.. , ,___________
-.. , ,___________
____Sample Size- 4 Media Type &Type W4 Sample Designation Date Time Code Code Code Comment, Preservation 9106-0006-004F 4/28/06 12:46 SE C BP X X Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP x x Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X X -Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP x x- Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP X X Transferred from COC 2006-00317 9106-0006-012F 4 5/21/06 13:40 SE C BP X X Transferred from COC 2006-00317 9106-0006-017F, 5/01/06 14:03 SE C BP X x Transferred from COC 2006-00317 NOTES: PO #: 002332 MSR #: 06- t4%1 SWP# NA M LTP n A r7 Q A M Non f-,A Samples Shipped Via: LI Fed Ex CHand 1) Relinquished By Date/Time  
____Sample Size- 4 Media Type &Type W4 Sample Designation Date Time Code Code Code Comment, Preservation 9106-0006-004F 4/28/06 12:46 SE C BP X X Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP x x Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X X -Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP x x- Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP X X Transferred from COC 2006-00317 9106-0006-012F 4 5/21/06 13:40 SE C BP X X Transferred from COC 2006-00317 9106-0006-017F, 5/01/06 14:03 SE C BP X x Transferred from COC 2006-00317 NOTES: PO #: 002332 MSR #: 06- t4%1 SWP# NA M LTP n A r7 Q A M Non f-,A Samples Shipped Via: LI Fed Ex CHand 1) Relinquished By Date/Time
: 2) Received By ( "ate/Time 3) Relinquished By Date/Time  
: 2) Received By ( "ate/Time 3) Relinquished By Date/Time
: 4) Received By 1  late/Time Bill of Lading #&#xfd;L wo- ?.ffo-4/ y Connecticut Yankee CY-ISC-SOW-O01 Statement of Work for Analytical Lab Services ..S -Figure 1. Sample Check-in List Datfime Rccived: " .*SDG#: Work Order Number ShippingCdiltainer ID: Qt Chain of CustodY# .&'1. CustodySeals ozshipping container intact?.: -Ys s No(_kD 2. Custody Seals dated and signed? Yes No 3. Chain-of-Custody reord present? Yesk).No [I I..4. Cooler temperature  
: 4) Received By 1  late/Time Bill of Lading #&#xfd;L wo- ?.ffo-4/ y Connecticut Yankee CY-ISC-SOW-O01 Statement of Work for Analytical Lab Services ..S -Figure 1. Sample Check-in List Datfime Rccived: " .*SDG#: Work Order Number ShippingCdiltainer ID: Qt Chain of CustodY# .&'1. CustodySeals ozshipping container intact?.: -Ys s No(_kD 2. Custody Seals dated and signed? Yes No 3. Chain-of-Custody reord present? Yesk).No [I I..4. Cooler temperature  
.1_5 * .we ."r 5. :Vermiculite/packing materials is: Wet ) Dry [' ]6. : -Number of samples in shipping containor 7. Sample holding imes exceeded?
.1_5 * .we ."r 5. :Vermiculite/packing materials is: Wet ) Dry [' ]6. : -Number of samples in shipping containor 7. Sample holding imes exceeded?
Line 816: Line 816:
~ U1-o S00u((91055 09,0t~ O53O 6 (0~ y-qqiq~00L(
~ U1-o S00u((91055 09,0t~ O53O 6 (0~ y-qqiq~00L(
nta, (h5.C je-3eJ haxcd m bt~sitd 5aM,_ __ __ __k_c ---- et S-('_4_bast _.d_ a~rnI Page 30 of 105'1 T." 11 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major CD 04 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00367 362 Injun Hollow Road, East Hampton, CT 06424 /'/Nae adanNc 860-267-2556  - -Lab Use Only Project Name: Hddam Neck Decommissioning Analyses Requested Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Aftt. Cheryl Jones C4 4 , t z Priority:
nta, (h5.C je-3eJ haxcd m bt~sitd 5aM,_ __ __ __k_c ---- et S-('_4_bast _.d_ a~rnI Page 30 of 105'1 T." 11 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major CD 04 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00367 362 Injun Hollow Road, East Hampton, CT 06424 /'/Nae adanNc 860-267-2556  - -Lab Use Only Project Name: Hddam Neck Decommissioning Analyses Requested Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Aftt. Cheryl Jones C4 4 , t z Priority:
Z 30 D. [ 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-001F 5/05/06 11:13 SE C BP X X X Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP X X x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X x x Transferred from COC 4 2006-00325 9106-0008-007F 5/5/06 15:03 SE C 13P X Transferred from COC # 2006-00325 9106-00 08-002F 5/5/06 13:10 SE C BP x x x Transferred from COC # 2006-00325 NOTES: PO 4: 002332 MSR#: 06- )7q3 SSWP#NA N LTP QA E3 Radwaste QA E] Non QA[E i I /1) elinqu sh Date/Time  
Z 30 D. [ 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-001F 5/05/06 11:13 SE C BP X X X Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP X X x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X x x Transferred from COC 4 2006-00325 9106-0008-007F 5/5/06 15:03 SE C 13P X Transferred from COC # 2006-00325 9106-00 08-002F 5/5/06 13:10 SE C BP x x x Transferred from COC # 2006-00325 NOTES: PO 4: 002332 MSR#: 06- )7q3 SSWP#NA N LTP QA E3 Radwaste QA E] Non QA[E i I /1) elinqu sh Date/Time
: 2) e ive Ya m  3) inquished By Date/Time  
: 2) e ive Ya m  3) inquished By Date/Time
: 4) Rdeeiveu Vy ate/Time aamples Shipped Via: 5; Fed Ex-uPs-Hand] Other 3ill of Lading #Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YO NO I Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-00366 MConnecticut Yankee Atomic Power Company W362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 11o3-7 41 V.Project Name: H{addam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 5.843 556 8171. Attn. Cheryl Jones En Z Priority:
: 4) Rdeeiveu Vy ate/Time aamples Shipped Via: 5; Fed Ex-uPs-Hand] Other 3ill of Lading #Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YO NO I Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-00366 MConnecticut Yankee Atomic Power Company W362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 11o3-7 41 V.Project Name: H{addam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 5.843 556 8171. Attn. Cheryl Jones En Z Priority:
N 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Comment, Preservation Lab Sample ID Sample Designation Date Time Code Code Code tJ) 9106-0008-008F 5/08/06 08:01 SE C BP X -X Transferred from COC # 2006-00327
N 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Comment, Preservation Lab Sample ID Sample Designation Date Time Code Code Code tJ) 9106-0008-008F 5/08/06 08:01 SE C BP X -X Transferred from COC # 2006-00327
_0 9106-0008_-009F 5/08/06 08:32 SE C BP x x x Transferred from COC # 2006-00327 oil 9106-0008-010F 5/08/06 09:09 SE C BP X X X Trans-fedfrom COC_#2006-00327-01I 91060008010F 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 OIL 9106-0008-01OFS 5/08/06 09:0 SE C BP x X X Transferred from COC # 2006-00327)It 9106-0008-01 IF 5/08/06 09:30 SE C 13P x ___ x x Taserdfo C 20-02 I1 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC # 2006-00327 9106-0008-013F 5/08/06 10:16 SE C BP X x x Transferred from COC # 2006-00327
_0 9106-0008_-009F 5/08/06 08:32 SE C BP x x x Transferred from COC # 2006-00327 oil 9106-0008-010F 5/08/06 09:09 SE C BP X X X Trans-fedfrom COC_#2006-00327-01I 91060008010F 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 OIL 9106-0008-01OFS 5/08/06 09:0 SE C BP x X X Transferred from COC # 2006-00327)It 9106-0008-01 IF 5/08/06 09:30 SE C 13P x ___ x x Taserdfo C 20-02 I1 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC # 2006-00327 9106-0008-013F 5/08/06 10:16 SE C BP X x x Transferred from COC # 2006-00327
&#xfd;5 9106-0008-014F 5/08/06 10:47 SE C BP x x x Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 67q3 SSWP# NA 0 LTP QA fl Radwaste QA [I Non QA Samples Shipped Via: 0 Fed Ex F1 ups l Hand El Other Bill of Lading#Internal Container Temp.: Z-I Deg. C Custody Sealed?YO N)!Custody Seal Intact?Y50 NO 1) Relinquished By Date/Time  
&#xfd;5 9106-0008-014F 5/08/06 10:47 SE C BP x x x Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 67q3 SSWP# NA 0 LTP QA fl Radwaste QA [I Non QA Samples Shipped Via: 0 Fed Ex F1 ups l Hand El Other Bill of Lading#Internal Container Temp.: Z-I Deg. C Custody Sealed?YO N)!Custody Seal Intact?Y50 NO 1) Relinquished By Date/Time
: 2) Received By Date/Time 3) Relinquished By Date/Time  
: 2) Received By Date/Time 3) Relinquished By Date/Time
: 4) Received By Date/Time Connecticut Yankee J1*3741 /Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:-
: 4) Received By Date/Time Connecticut Yankee J1*3741 /Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:-
6&iWb'Qo M 2\ )SDG#: Work Order Number: Shipping C*otainer ID: .--fr/, Chain of Custody # 3 OOo -00 ( Pq I. Custody Seals oan shipping container intact?. Yes [-,1' o 4 1 2. Custody Seals dated and signed? Yesj[1 No q[-3. Chain-of-Custody record present? Yes [-'o [ ].4. Cooler temperature
6&iWb'Qo M 2\ )SDG#: Work Order Number: Shipping C*otainer ID: .--fr/, Chain of Custody # 3 OOo -00 ( Pq I. Custody Seals oan shipping container intact?. Yes [-,1' o 4 1 2. Custody Seals dated and signed? Yesj[1 No q[-3. Chain-of-Custody record present? Yes [-'o [ ].4. Cooler temperature
Line 869: Line 869:
Z 30 D. El 14 D. El 7 D. Container Sample Size-Media Type &Type ." Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID9106-0009-016F 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352
Z 30 D. El 14 D. El 7 D. Container Sample Size-Media Type &Type ." Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID9106-0009-016F 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352
~ 9106-0009-01 6FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 08:05 SE C BP -X Transferred from COC 2006-00351 0 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 m 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 OiV 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 9106-0009-014F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 9106-0009-015F  
~ 9106-0009-01 6FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 08:05 SE C BP -X Transferred from COC 2006-00351 0 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 m 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 OiV 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 9106-0009-014F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 9106-0009-015F  
~ ~~~ ~ 5/'50 093IEC B rnfre rmCC20-05 NOTES: PO #: 002332 MSR #: 06-O/g' SSWP# NA SLTP QA El Radwaste QA El Non QA 1) Relinquised By Date/Time  
~ ~~~ ~ 5/'50 093IEC B rnfre rmCC20-05 NOTES: PO #: 002332 MSR #: 06-O/g' SSWP# NA SLTP QA El Radwaste QA El Non QA 1) Relinquised By Date/Time
: 2) Rec v d y Date/Time 3) Relinquished By Date/Time  
: 2) Rec v d y Date/Time 3) Relinquished By Date/Time
: 4) Re eive By Date/Time Samples Shipped Via:[ Fed Ex El uis El Hand El Other Bill of Lading #&#xa2;qz/.VS 2A-Internal Container Temp.: ___ Deg. C Custody Sealed?YO NO Custody Seal Intact?Y 17 N !"
: 4) Re eive By Date/Time Samples Shipped Via:[ Fed Ex El uis El Hand El Other Bill of Lading #&#xa2;qz/.VS 2A-Internal Container Temp.: ___ Deg. C Custody Sealed?YO NO Custody Seal Intact?Y 17 N !"
Health Physics Procedure/ 1,4 gva -/.GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 1l I I I I l CD 0(C U Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C V Priority:
Health Physics Procedure/ 1,4 gva -/.GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 1l I I I I l CD 0(C U Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C V Priority:
Line 884: Line 884:
___9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321
___9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321
-9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 0 6 9106-0010-010F 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 o 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321
-9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 0 6 9106-0010-010F 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 o 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321
-0 9106-0010-013F 5/04/06 15:06 SE C BP X Transferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 07*07 SSWP#NA SLTP QA El Radwaste QA 0l Non QA 1) RelinquisheABy Date/Ti e 2) Received y Date/Time 3) Relinquished By DatefIime  
-0 9106-0010-013F 5/04/06 15:06 SE C BP X Transferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 07*07 SSWP#NA SLTP QA El Radwaste QA 0l Non QA 1) RelinquisheABy Date/Ti e 2) Received y Date/Time 3) Relinquished By DatefIime
: 4) Received By Date/Time Samples Shipped Via:[ Fed Ex EUPS ElHand El Other Bill of Lading I#~904- 3 &#xfd;f Internal Container Temp.: /7Deg. C CustodySealed?
: 4) Received By Date/Time Samples Shipped Via:[ Fed Ex EUPS ElHand El Other Bill of Lading I#~904- 3 &#xfd;f Internal Container Temp.: /7Deg. C CustodySealed?
Y9" NO Custody Seal Intact?Y 9 ND Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SoW-O01 Figure 1. Sample Check-in List D a t e / T i m e R e c e iv e d : qMf /7 / .0 6 , SDG #: n U le .Q C# -7t9"70 Work Order Number: Shipping Ccfitainer ID : rt5 Chain of Custody # -6 3 9 1. Custody Seals ori shipping container intact? -Yes [(] No [ J 2. Custody Seals dated and signed? Yes [V No [ I. -3. Chain-of-Custody record present? Yes [D No [ ]4. Cooler temperature (7 C 5. Vermiculite/packing materials is: Wet pq Dry I' J 6: ! *Number of samples in shipping container:
Y9" NO Custody Seal Intact?Y 9 ND Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SoW-O01 Figure 1. Sample Check-in List D a t e / T i m e R e c e iv e d : qMf /7 / .0 6 , SDG #: n U le .Q C# -7t9"70 Work Order Number: Shipping Ccfitainer ID : rt5 Chain of Custody # -6 3 9 1. Custody Seals ori shipping container intact? -Yes [(] No [ J 2. Custody Seals dated and signed? Yes [V No [ I. -3. Chain-of-Custody record present? Yes [D No [ ]4. Cooler temperature (7 C 5. Vermiculite/packing materials is: Wet pq Dry I' J 6: ! *Number of samples in shipping container:
Line 1,185: Line 1,185:
%Value Frequency Frequency 0.00 5 33%0.02 9 60%0.04 1 7%Total 15 100%Prepared By: Date: / 0 -Z -&#xfd; ...Z Reviewed By: Date: .e 5-DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)
%Value Frequency Frequency 0.00 5 33%0.02 9 60%0.04 1 7%Total 15 100%Prepared By: Date: / 0 -Z -&#xfd; ...Z Reviewed By: Date: .e 5-DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)
Health Phvsics Procedure GPP-GGGR-R512 1-000 Attachment A. Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes
Health Phvsics Procedure GPP-GGGR-R512 1-000 Attachment A. Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes
;urvey Unit Number: 9106-0002 Survey Unit Name: WP&IR#: Discharge Canal Classification  
;urvey Unit Number: 9106-0002 Survey Unit Name: WP&IR#: Discharge Canal Classification
: 2 TYPE I (cQ error):0.05 TYPE I (b error):0.05 Radionuclides:
: 2 TYPE I (cQ error):0.05 TYPE I (b error):0.05 Radionuclides:
Cs-137 Co-60 Sr-90 Survey Design DCGL (pCi/g): 5.38 2.59 0.62 Results Cs-137 Results Co-60 Results Sr-90 Weighted Sum (Ws) DCGL-Result Sign 2.64E-02 2.13E-02 2.13E-02 2.251E-02 9.78E-01 I 1.23E-01 1.19E-01 1.19E-01 7.56E-02 9.24E-01 1 1.98E-01 2.88E-01 2.88E-01 1.55E-01 8.45E-01 1 3.81E-01 6.39E-01 6.39E-01 3.24E-01 6.76E-01 I 1.63E-01 3.70E-01 3.70E-01 1.81E-01 8.19E-01 I 1.84E-01 2.31E-01 2.3 1E-01 1.26E-01 8.74E-01 1 6.61E-02 2.38E-01 2.38E-01 9.41 E-02 9.06E-01 I 2.47E-01 5.26E-01 5.26E-01 2.68E-01 7.32E-01 I 1.75E-01 1.1 8E-01 1.18E-01 7.38E-02 9.26E-01 I 2.431E-02 1.51E-01 1.51E-01 6.23E-02 9.38E-01 I 0.OOE+00 1.46E-03 1.46E-03 -1.67E-03 1.OOE+00 I 1.16E-01 5.07E-02 5.07E-02 4.55E-02 9.55E-01 I 9.30E-02 8.07E-02 8.07E-02 6.88E-02 9.31 E-0 I 8.09E-02 1.45E-01 1.45E-01 7.82E-02 9.22E-01 1.69E-01 1.21E-01 1.21E-01 6.57E-02 9.34E-01 Number of Positive Differences (S+): 15 Critical Value: I I Survey Unit: Meets Acceptance Criterion Performed By: _ _ __Z _ ______ Date:_____________
Cs-137 Co-60 Sr-90 Survey Design DCGL (pCi/g): 5.38 2.59 0.62 Results Cs-137 Results Co-60 Results Sr-90 Weighted Sum (Ws) DCGL-Result Sign 2.64E-02 2.13E-02 2.13E-02 2.251E-02 9.78E-01 I 1.23E-01 1.19E-01 1.19E-01 7.56E-02 9.24E-01 1 1.98E-01 2.88E-01 2.88E-01 1.55E-01 8.45E-01 1 3.81E-01 6.39E-01 6.39E-01 3.24E-01 6.76E-01 I 1.63E-01 3.70E-01 3.70E-01 1.81E-01 8.19E-01 I 1.84E-01 2.31E-01 2.3 1E-01 1.26E-01 8.74E-01 1 6.61E-02 2.38E-01 2.38E-01 9.41 E-02 9.06E-01 I 2.47E-01 5.26E-01 5.26E-01 2.68E-01 7.32E-01 I 1.75E-01 1.1 8E-01 1.18E-01 7.38E-02 9.26E-01 I 2.431E-02 1.51E-01 1.51E-01 6.23E-02 9.38E-01 I 0.OOE+00 1.46E-03 1.46E-03 -1.67E-03 1.OOE+00 I 1.16E-01 5.07E-02 5.07E-02 4.55E-02 9.55E-01 I 9.30E-02 8.07E-02 8.07E-02 6.88E-02 9.31 E-0 I 8.09E-02 1.45E-01 1.45E-01 7.82E-02 9.22E-01 1.69E-01 1.21E-01 1.21E-01 6.57E-02 9.34E-01 Number of Positive Differences (S+): 15 Critical Value: I I Survey Unit: Meets Acceptance Criterion Performed By: _ _ __Z _ ______ Date:_____________

Revision as of 09:11, 13 July 2019

Final Status Survey Final Report Phase IV, Appendix A2, Survey Unit Release Record 9106-0002, Discharge Canal
ML063400431
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/06/2006
From: Newson C
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9106-0002
Download: ML063400431 (273)


Text

Book of 1 Final Status Survey Final Report Phase IV Appendix A2 Survey Unit Release Record 9106-0002, Discharge Canal November 2006 CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0002 Prepared By: Reviewed By: Approved By: FSS Engineer Egineer Date: //- -Od Date: Date:__Technical Support Manager Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

................................................................

3 2. CLASSIFICATION BASIS .......................................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ...................................................

5 4. SURVEY DESIG N ...................................................................................

9 5. SURVEY IMPLEMENTATION

................................................................

12 6. SURVEY RESULTS ...............................................................................

13 7. QUALITY CONTROL .............................................................................

14 8. INVESTIGATIONS AND RESULTS .......................................................

15 9. REMEDIATION AND RESULTS ............................................................

15 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .....................

15 11. DATA QUALITY ASSESSMENT (DQA) ...............................................

15 12. A NO M A LIES ..........................................................................................

16 13. CO NC LUSIO N ........................................................................................

16 14. ATTACHMENTS

....................................................................................

17 14.1 Attachment 1 -Figures (5 pages including cover)14.2 Attachment 2 -Sample and Statistical Data (249 pages including covers)Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD 1. SURVEY UNIT DESCRIPTION Survey Unit 9106-0002 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 5520 m2 ( 1.36 acres) of water covered sediment in an area located approximately 0.20 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes.

The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0014 is to the north, (called north as orientated with the north to south flow of the Connecticut River), survey unit 9521 is to the east, Discharge Canal Survey Unit 9106-0003 is to the south and Survey Area 9520 is to the west. The Survey Unit comprises the canal sediments to the depth of three (3) feet from the top of the sediment layer or the original construction depth and it extends up the canal banks to the mean high water level.This survey unit is bounded by reference coordinates E006 through E010 by S077 through S081 (refer to License Termination Plan Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0002 as Class 2 in May 2006.The "Classification Basis Summary" conducted for this survey unit consisted of: a) A review of the IOCFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement, " c) Historic and current survey records review, d) Visual inspections and a "walkdown." e) Formal or informal interviews with cognizant personnel.

A review of the IOCFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment.

The sample analyses indicated that the Revision 0 3 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86).

None the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00).

These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.An initial characterization survey of the Discharge Canal was performed during April and May of 2004. However, none of these samples were taken from within the footprint of Survey Unit 9106-0002.

A final characterization was performed by Site Closure personnel in April of 2006 to obtain the necessary data of sufficient data quality for Final Status Survey (FSS) planning purposes.

Seven (7) 3-foot core sediment samples were taken from seven (7) locations.

All of the samples were analyzed by gamma spectroscopy.

Hard-to-Detect analyses were also conducted on one (1) of the seven (7) samples. Sr-90 was found to be a nuclide of concern based on the analysis of the sample. Since a variance cannot be determined from one (1)sample result, the variance associated with the fifteen (15) characterization samples measured for Sr-90 in an adjacent Survey Unit (SU9106-0003) was applied. Although no additional HTD testing was performed for characterization; four (4) of the fifteen (15) samples taken to demonstrate compliance with the release criteria during FSS were tested for the full suite of HTD nuclides to provide additional assurance that all of the radionuclides of concern were appropriately addressed.

As a result of characterization, the radionuclides of concern identified for FSS planning purposes were Cs-137, Co-60 and Sr-90 (refer to Table 1).Revision 0 4 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Table I --BasicStatisticl s437Co60 and from the Paae - -- I Cs-137 (pCiig) Co-60' (pijg) Sr-90 (pCiu )Minimum Value: 4.58E-02 -4.90E-03 9.43E-04 Maximum Value: 3.93E-01 2.53 E-01 3.77E-02 Mean: 1.64E-01 9.59E-02 1.45E-02 Median: 1.53E-01 8.72E-02 1.08E-02 Standard Deviation:

1.18E-01 7.94E-02 1.1OE-02 NOTE: The Operational DCGLs are 5.38 pCi/g for Cs-137, 2.59 pCi/g for Co-60 and 1.05 for Sr-90; these are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE The FSS Engineer performed a visual inspection and walkdown during May 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLsjustifying a final survey unit classification of Class 2 (refer to Section 3).3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0002 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the Revision 0 5 Revision 0 5 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario.

Consequently, the soil DCGLs are directly applied to the canal sediment media.The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation I shows the mathematical relationship between the three (3) components and the total dose.Equation 1: HTotal=Hsoil (sediment)

+/- HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.This survey unit is affected by existing groundwater, but is unaffected by future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from existing groundwater is two (2) mrem/yr TEDE, based on field data.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings remaining within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contributions from future groundwater, the third component is, therefore, zero (0) mrem/yr TEDE.Revision 0 6 Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Equation 2.19 mrem/yriotal=

17 mrem/yrsoil+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is nineteen (19 )mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Table: 2- Radionuclide Specific BaseGCase Soil DCGL, Operational DCGGs and Reuuired Minimum Detectable Concentrations, Radionuclide

'i Base Case Soil 0perational DCGL Rqie lD H-3 DCGL (pCi/g) (2) wK(pC i/ 1 (3)() (PCi/gj) (4)H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+O1 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+O1 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+0I Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Characterization was performed in April and May of 2004 as discussed in Section 2. Cesium-137, Cobalt-60 and Strontium-90 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median)for Cs-137, Co-60 and Sr-90 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) were not accepted for FSS. Sample report Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined.

Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is seventeen (17) mrem/yr TEDE, as discussed in Section 2 of this Release Record.The DQO process determined that Cs-137, Co-60 and Sr-90 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Sr-90) were considered in the survey design.Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Sr-90 concentrations in sediment and soil were ascertained by direct analysis.Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected.

This process was applied to analysis data for this survey unit.The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected.

The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in Revision 0 9 Revision 0 9 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD accordance with Procedure RPM 5.1-11 to 0.867 to maintain the relative shift (A/a) in the range of I and 3. The resulting relative shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for. implementation of MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.Subsequent to the initial design, the northern boundary of the survey unit was moved southward.

The following are summary explanations of the design considerations and how these affected Survey Unit 9106-0002:

  • An adjacent survey unit (SU 9106-0001) was reclassified to a Class I area.* Since SU 9106-0001 exceeded the 2000 m2 size limit for a Class I area, it was divided into a northern survey unit (SU 9106-0001) and a southern survey unit (SU 9106-0014)." In order to maximize the area of the two (2) Class I Survey Units, the boundaries of Survey Units 9106-0002 and 9106-0014 were pushed southward.
  • Changing the boundaries placed three (3) statistical sample locations (001F, 003F and 006F) and one (1) bias sample location (016F) outside of Survey Unit 9106-0002.
  • The affected statistical sample locations were replaced with three (3)randomly generated sample locations (017F, 018F and 019F).*The biased location was not relocated as it was placed to target an area of interest that was removed from the survey unit as a consequence of the boundary change.Revision 0 10 Revision 0 10 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.Table 3 -Sample Measur~ement Locations withbAss-ociated GPS Coordinates Designati Ea~stiig 9106-0002-002F 236170.95 669239.34 9106-0002-004F 236106.91 669202.36 9106-0002-005F 236106.91 669276.31 9106-0002-007F 236042.86 669165.39 9106-0002-008F 236042.86 669239.34 9106-0002-009F 236042.86 669313.29 9106-0002-01 OF 235978.82 669202.36 9106-0002-01 IF 235978.82 669276.31 9106-0002-012F 235978.82 669350.26 9106-0002-013F 235978.82 669424.21 9106-0002-014F 235914.78 669313.29 9106-0002-015F 235914.78 669387.24 9106-0002-017F 236170.95 669165.39 9106-0002-018F 236170.95 669239.34 9106-0002-019F 236106.91 669128.41 Although Procedure RPM 5.1-11 specifies that only 5% of the samples need to be selected for HTD analysis, four (4) soil samples were analyzed for HTDs, exceeding the 5% procedural requirement.

Two (2) samples were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RAND" function.

In addition, two (2) samples, which were determined to contribute the greatest dose based on gamma only analyses, were also selected for HTD analyses.

Each sample would be sent off-site for a full suite analysis of the HTD radionuclides specified in Table 2.The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel"RAND" function.

The number of quality control samples exceeded the LTP requirement of 5%.The LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.Revision 0 I1I DISCH4ARGE CANAL SURVEY UNIT 9 106-0002 RELEASE RECORD survey unit Land Area 5,520 m 2 tsasea on AUtOAL)-L i ana v isuai Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was .0666. the LBGR was set to Measurements 0.867 to maintain Relative Shift in the range of I and 3, Relative Shift was 2.0 Grid Spacing 20.61 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve 10 mrem/yr TEDE 0.62 pCi/g Sr-90 Operational 5.38 pCi/g Cs-137 To achieve 17 mrem/yr Oril 2.59 pCi/g Co-60 TEDE (2) to demonstrate compliance with 1.05 pCi/g Sr-90 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 5.3 8 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.59 pCi/g Co-60 criteria for a Class 2 survey unit Level 1.05 pCi/g Sr-90 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the total dose from existing and future groundwater has been established (reference CY memo ISC 06-024)5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Survey, Inc.(OSI) of Old Saybrook, Connecticut.

Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments.

Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten feet or less).A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample Revision 0 12 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD locations were accomplished using a GPS interfaced with a navigation and data logging system.After extraction, water was drained from above the sample by drilling holes above the sediment.

The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. " Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey ". Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Four. (4) samples (9106-0002-004F, 9106-0002-007F, 9106-0003-0011 and 9106-0003-012F) were selected for HTD radionuclide analysis by the off-site laboratory.

The implementation of quality control measures included the collection of two (2) split samples at locations 9106-0002-014F and 9106-0002-018F for comparative analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) -Charleston, South Carolina.

The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Sr-90 was analyzed by gas flow proportional counting.

All analyses were performed to the required MDC.Cesium-137 met the acceptance criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) in thirteen (13), Co-60 met the accepance criteria for detection in fourteen (14) and Sr-90 met the acceptance criteria for detection in two (2) of the fifteen (15) samples.Several other radionuclides that met the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.The off-site laboratory also processed four (4) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. Four Revision 0 13 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD (4) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.None of the sample results exceeded the Operational DCGL or required further investigation.

A summary of the sample results is provided in Table 5.91 Ub-UUU2-UU21t 2.64L-02 2. 13E-U0 9.&iz -Ui Z.ZDL-U2 9106-0002-004F 1.23E-01 1.19E-01 7.1 OE-03 7.56E-02 9106-0002-005F 1.98E-01 2.88E-01 7.01E-03 1.55E-01 9106-0002-007F 3.81 E-01 6.39E-01 6.81 E-02 3.82E-01 9106-0002-008F 1.63E-01 3.70E-01 7.85E-03 1.81E-01 9106-0002-009F 1.84E-01 2.31E-01 2.94E-03 I1.26E-0 I 9106-0002-01 OF 6.61 E-02 2.38E-01 -1.06E-02 9.41 E-02 9106-0002-011 F 2.47E-01 5.26E-01 1.95E-02 2.68E-01 9106-0002-012F 1.75E-01 1.1 8E-01 -4.47E-03 7.38E-02 9106-0002-013F 2.431E-02 1.51 E-0 1 -4.97E-04 6.23E-02 9106-0002-014F 0.OOE+00 1.46E-03 -2.35E-03

-1.67E-03 9106-0002-01 5F 1.166E-01 5.07E-02 4.55E-03 4.55E-02 9106-0005-017F 9.30E-02 8.07E-02 2.14E-02 6.88E-02 9106-0005-018F 8.09E-02 1.45E-01 7.58E-03 7.82E-02 9106-0005-019F 1.69E-01 1.21 E-01 -1.31 E-02 6.57E-02 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137, 2.59 pCi/g for Co-60 and 1.05 for Sr-90; these are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE Biased sampling was not required to resolve anomalies or to account for survey unit irregularities.

7. QUALITY CONTROL The two (2) split samples taken for QC were analyzed by the off-site laboratory.

The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24,"Split Sample Assessment for Final Status Survey. " One (1) split-sample (9106-0002-018F/S) did not meet the comparison criterion for Co-60. A possible cause for this anomaly could be the presence of Co-60 in the form of discrete particles.

Such a physical form does not lend itself to homogenous mixing in a sediment matrix and, therefore, is not necessarily an indicator of inadequate sampling or sample preparation methodology.

In this sample, Cs-137 and K-40, a natural radioisotope, were both found to be present at acceptable levels of agreement, therefore, the comparison was determined to be Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD acceptable.

For the other QC split samples, there was an acceptable level of agreement between the samples for the radionuclides of concern.The sample analysis vendor, GEL, maintained quality control and quality assurance plans as part of normal operation.

Refer to Attachment 2 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS Sample investigation levels were not exceeded for this unit, consequently none were performed.

9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE, which was conservative and necessary at the time of FSS planning.

It is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used to demonstrate compliance with the LTP criteria is seventeen (17)mrem/yr TEDE as discussed in Section 2 of this Release Record.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passes FSS.Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

Revision 0 15 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2g. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of the LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.The range of the data, about 3.84 standard deviations, was not unusually large.The difference between the mean and median was 37.5% of the standard deviation which indicates some skewness in the data. The data's represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.69.All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES The anomaly associated with the disagreement between the field split number 9106-0002-018F/S has been discussed in Section 7. The source of the disagreement for Co-60, was likely due to Co-60 being present in the form of discrete particles.

Such a physical form does not lend itself to homogenous mixing in a sediment matrix. However, comparisons of results for other radionuclides present in the sample were sufficient to demonstrate appropriate implementation of sampling Quality Controls.13. CONCLUSION Survey Unit 9106-0002 has demonstrated compliance with the dose based, unrestricted release criterion.

The sample data passed the Sign Test and the null hypothesis was rejected.

The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Reclassification and remediation of this survey unit was not required.Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit was properly designated as a Class 2 survey unit.The dose contribution from sediment in this survey unit is 1.9 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.Revision 0 16 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is bounded by 2.0 mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, 0 mrem/yr TEDE.The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3.9 mrem/yr Total Effective Dose Equivalent (TEDE).14. ATTACHMENTS 14.1 Attachment I -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 0 17 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 1 Figures (4 pages)

Connecticut Yankee Atomic Power Company Fig ISite Map With Reference To Survey Unit 9106-0002 owl 0 0 13 4 12 8 0 15 Dw to C-W Current Swvey Unit Boundwy Bonday of Ame Removed Suivey Unit to Become Padl Of 9106-004.7 0 17 Wetlands Note 0 20 40 Connecticut Yankee Atomic Power Company 9106-0002 Final Status Survey Sample Locations E: 1), ý0 A ctual Sample Locaton as zacoided by Ocean Siuveys, Inc.0 0.123 SwtveyPlan Due to Bound&y chanp-Crrent Survey Unit Boun day 0.175 0.163 0.116 0.247 0.381 0.093 Ame Removed Aum Onig&W Survey Unit tu eome Pmtl Of 9106-004.4Li4 Wegands Notes Points 1,3,6 and 16 lie outside the revigdabou0d0y for 9106-0002 Cesiumn-37zasults re givenin pCilg.0 20 40 L tomic Power C f Status Survey ostina Plot

%ýý -\11o 0 0, D --0~)Actual Sample Locadon as worxded by Ocean Sorveys Inc.0 0.151 0.119 0 SurveyPlan Due to Bouadai chaw Survey Unit Boundaiy 0.118 0 0.37 0 0.051 0 0.639 0 0.526 0.081__Boundiy of Arm Removed fim Orn&W Survey Unt to Become Prt of 9106-0014.

~\Lwetlands NMtes Points 1,3,6 and 16 lie outside the zmiyed bounduy for 9106-0002 Cobalt-60 results are given in pCig.0 20 40 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2 Sample and Statistical Data DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2a Sample Data (229 Pages)

Table of Contents G eneral Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

4 Radiological Analysis ..........................................................

11 Sample Data Summary ......................................................

30 Q uality C ontrol D ata ...........................................................

62 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 164220 SDG: MSR #06-0755 June 30, 2006 Laboratory Identification:

General Engineering Laboratories, LLC MailingZ Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on June 02, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 164220001 9106-0002-OOIF 164220002 9106-0002-002F 164220003 9106-0002-003F 164220004 9106-0002-004F 164220005 9106-0002-005F 164220006 9106-0002-006F 164220007 9106-0002-006FS 164220008 9106-0002-007F 164220009 9106-0002-008F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.P.O. Box 30712 -Charleston, SC 29417

  • 2040 Savage Road (29407)Phone (843) 556-8171
  • Fax r43) 766-1178 ° www.gel.com 164220010 9106-0002-009F 164220011 9106-0002-OIOF 164220012 9106-0002-01 IF 164220013 9106-0002-012F 164220014 9106-0002-013F 164220015 9106-0002-014F 164220016 9106-0002-014FS 164220017 9106-0002-015F 164220018 9106-0002-016F Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Sixteen sediment samples were analyzed for FSSGAM and Sr-90.Two sediment samples were analyzed for FSSALL.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.P.O. Box 30712

  • Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171
  • Fax (843) 766-1178 .www.gel.com Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major rLI Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn 4.Priority:

Z 30 D. E] 14 D. L] 7 D. Container Sample Size- ,dq Z Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-001Fe 5/17/06 10:42 SE C BP X X Transferred from COC 2006-00357 9106-0002-002F 5/18/06 09:43 SE C BP X Transferred from COC 2006-00361 9106-0002-003F&

5/18/06 10:14 SE C BP X X Transferred from COC 2006-003 61 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F' 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP X X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP X x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP X X Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal o- 55 Z Fed Ex Container El UPS Temp.: CajLa 0-b-~ r~lo ( 6A ~ Deg. C Cj- o .;l Hand Custody Sealed?Rel qu By Date/Time

2) .ived By Date/Time Custody Seal M ;"-aO LI Other Intact?I)Telinqtuished 9 Date/Time
4) Received By Date/Time YO NO Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 7'09 9/16 .7/0 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major ON~Chain of Custody FormNo206037 Connecticut Yankee Atomic Power Company No. 2006-00372 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 <843 556 8171. Attn. Cheryl Jones L C , Priority:

E 30 D. F] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-011 F 5/19/06 08:10 SE C BP X X Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-014FSjo 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal 0755 [ Fed Ex Container El UPS Temp.:* '-~c% A +iuA*L1 4 1 0ovt4v'; O~e4- C b i$/&Deg. C El,.u Hand Custody Sealed?1 n Date/Time

2) ReMved By Dat Time Custody Seal , ( El Other Intact?3)x(elinquished By Date/Time
4) Received By Date/Time BillofLdin9Y E N E Bill of Lading B 5) Relinquished By Date/Time
6) Received By Date/Time 7'qoq z/Y'*" z57 1~c1 Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received: -, ')V 2 9Q SDG#: Work Order Number:-.

.L 2-" Shipping Cdntainer ID] P(O Y!L,5I2/4' Chain of Custody # 4 cQ" 7!1. Custody Seals ori shipping container intact?.. -Yes No[ ]2. Custody Seals dated and signed? Yes JN [No ].3. Chain-of-Custody record present? Yes ,TNo ]4. Cooler temperature

_ 9.5. .Vermiculite/packing materials is: Wet [ ] Dry , Ofe h 6." Number of samples in shipping container:

7. Sample holding times exceeded?

Yes f 1 No I 5-v--- " " -- 1N ,8. Samples have:-tape -hazard labels..cstody seals --appropri Iate sample labels 9. Samples are..'.-4 in good condition

"-leaking-broken -... .have air bubbles 10.11.Were any anomalies identified in sample receipt? Yes [ ] NoX]Description of anomalies (include sample numbers): Sample. Custodian/Laboratory:-

_ _ Date.Telephoned to: * --.On By-: ..7 SAMPLE RECEIPT & REVIEW FORM 0 PM use only Client: ( 4 1 navoe r ý c ' '(f u k 'e. .SDGIARCOC/Work Order: (L'22C)Date Received:

'PM(A) Review (ensure non-cotaonning items are resolved prior to signing): Received By: Sample Receipt Criteria Z Comments/Qualibrers (Required for Non-Conforming Items)S hip peCing codtainer s r ci ved n ac Circle Applicable:

seals broken damaged container Ie g container other (describe) and sealed?Samples requiring cold Circle Coolant # ice bags blue ice dry ice none other describe)2 preservation within (4 +I-/- 2 C)?-Record preservation method.____________________________

3Chain of custody documents 3 included with shipment?

....._ _ _4 Sample containers intact and Circle Applicablesea1s broken damaged container leaking container other idescribe) lsealed?I Samples requiring chemical Sanjp.I. &Sm -conta.iners affected and observ.d p.: preservation at proper pH? I___________________I________

99 12 6 (defined as < 6mm bubble)?I C ncrs a _: I 7 Are Encore containers present?(If yes, immediately deliver to VOA laboratorv)

/I Samples received wi " holding time? I/)Sample ID's 9 a'COC match ID's on bottles?/Id's and tests affected: 'Sample tDs and containers affcted: Sample ID's affected: Sample ID's affected: Date & tme on COC match date I& tit 6 on bottles?l Nufber of containers received match number indicated on COC?COC form is properly signed in relinquished/received sections?-- C ý& -2,0 0 (e -00 3T I 14'Air Bill ,Tracking

  1. 's, &Additional Comments 1 I I Suspected Ha A Radiological B FB Rgulated C Material?

If yes Manager or ES PM (or PMA) re V Z RSO RAD Receipt_ ___ ____#, rd InRArRceitn if > x2 area background is observed on samples identified as non-zard Inform ation non ap reguJated/non-radioactive" , contact the Radiation Safety group for hiu lher ax Ix investigation.

asif,"in?

-M xm mCO ns Observed*: " ,'3U "- Comments: azRgar ous s, contact Waste Hazard Class Shipped: l Manager. r N#: eview of Hazard classiticationw Initials Date: B Connecticut Yankee Statement of Work for Analytical Lab Services .cy-Isc-sow-001I Figure 1. Sample Check-in List.Date/Time Received &/Tk (2 SDG#: -o -qo Work Order Number: .QLA"-' '[""Shipping Cctainer I Chain of Custody3 1. Custody Seals on" shipping container intact? "Yes No []2. Custody Seals dated and signed? Yes A] No [ ]3. Chain-of-Custoly record present? e. Yes No [].4. Cooler temperature

5. Vermiculite/packing materials is: Wet [ Dry j3] -6.' Number of samples in shipping container:

____7. Sample holding times exceeded?

Yes [ No 8. Samples have:-tape ___hazard labels-Custody seals appropriate sample labels 9. Samples are.'.. in good condition -leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No -11. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:

f; .Date.: 6 "o "" Telephoned to: On .y -" 9

-SAMPLE RECEIPT & REVIEW FORM 0 PM use only CI Cie-Tnt: ecF1L f (0( ec SDG/ARCOCi'Werk Order: &C-'yozo Date Received:

[ o PM(A) Review ( re non-conro ug i are reoved prior to signing): Received By:I Sample Receipt Criteria Comments/Qualifiers equired for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broke damaged container leaking container other (describe) and sealed? 1 7 Samples requiring cold Circle Coolant # ic ags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?4 Sample containers intact and Cird Applicable:

seals broken damaged container leaking container odter (describe) sealed?5 Samples requiring chemical Sample ID's. containers affected and observed pH: preservalion at proper pH?6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

Samples received within holdin Idas and tests affected: time? /9 Sample ID's on COC lnatc ID's Sample ID's and containers affected: on bottles?Date & time on COC tch date Sample ID's affected:& time on bottles? _Number of container received Sample ID's affected: match number indic ted on COC?12 COC form is propirly signed in _""-2 relinquished/received sections?

coc-- Z G ec5. -&6,1 I" Air Bill ,Tracking

  1. s, &Additional Comments"V 10 Z RSO RAD Receipt #Suspected Hazard In formation

-*If > x2 area background is observed on samples identified as "non-,jU .regulated/non-radioactive", contact the Radiation Safety group for further A _RadiologicalClassification?

investigation.

Radiological Classification?

Maximum Counts Observed-;

r Pm B PCB Regulated?

Comments: jShipped as DOT Hazardous c M Material?

If yes, contact Waste Hazard Class Shipped: NManager or ESH Manager. UN#: PM (or PMA) review of Hazard classitication:

Initials Date: Lpj[- 0(10 RADIOLOGICAL ANALYSIS 11 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 164220 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 540462 535702 535666 Sample ID 164220002 164220010 1201117597 1201117598 1201117599 1201117600 Client ID 9106-0002-002F 9106-0002-009F Method Blank (MB)164220002(9106-0002-002F)

Sample Duplicate (DUP)164220002(9106-0002-002F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12 Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201117598 (9106-0002-002F) was recounted due to a peak shift.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 13 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 540464 535702 535666 Sample ID 164220002 164220010 1201117601 1201117602 1201117603 1201117604 Client ID 9106-0002-002F 9106-0002-009F Method Blank (MB)164220002(9106-0002-002F)

Sample Duplicate (DUP)164220002(9106-0002-002F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.14 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu- 11-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 540465 535702 535666 15 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201117605 Method Blank (MB)1201117606 164220002(9106-0002-002F)

Sample Duplicate (DUP)1201117607 164220002(9106-0002-002F)

Matrix Spike (MS)1201117608 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201117605 (MB) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16 referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 164220002 164220004 164220005 164220007 164220008 164220009 164220010 164220011 164220012 164220013 164220014 164220015 164220017 164220018 1201107352 1201107353 1201107354 EML HASL 300,4.5.2.3 Dry Soil Prep 536186 535666 Client ID 9106-0002-002F 9106-0002-004F 9106-0002-005F 9106-0002-006FS 9106-0002-007F 9106-0002-008F 9106-0002-009F 9106-0002-01OF 9106-0002-01 IF 9106-0002-012F 9106-0002-013F 9106-0002-014F 9106-0002-015F 9106-0002-016F Method Blank (MB)164220002(9106-0002-002F)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 17 narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information 18 Qualifier U1 Reason Analyte Data rejected due to high full width half maximum. Cesium-134 Cesium- 137 Manganese-54 Data rejected due to interference.

Europium-155 UI Sample 164220012 164220015 164220014 164220010 164220012 164220018 164220015 164220005 164220007 164220017 164220018 Manganese-54 Cesium- 134 U'Data rejected due to low abundance.

Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr90, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 539388 535702 535666 19 Sample ID 164220002 164220004 164220005 164220007 164220008 164220009 164220010 164220011 164220012 164220013 164220014 164220015 164220017 164220018 1201114898 1201114899 1201114900 1201114901 Client ID 9106-0002-002F 9106-0002-004F 9106-0002-005F 9106-0002-006FS 9106-0002-007F 9106-0002-008F 9106-0002-009F 9106-0002-01OF 9106-0002-01 IF 9106-0002-012F 9106-0002-013F 9106-0002-014F 9106-0002-015F 9106-0002-016F Method Blank (MB)164220002(9106-0002-002F)

Sample Duplicate (DUP)164220002(9106-0002-002F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s)Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.20 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 164220014 (9106-0002-013F) was recounted due to being originally counted on a detector that did not meet daily background and efficiency checks. Sample 164220013 (9106-0002-012F) was recounted due to the activity of the sample being between two and three sigma TPU.Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: Analytical Batch Number: Sample ID 164220002 164220010 1201107610 1201107611 1201107612 1201107613 DOE EML HASL-300, Tc-02-RC Modified 536314 Client ID 9106-0002-002F 9106-0002-009F Method Blank (MB)163741008(9106-0008-007F)

Sample Duplicate (DUP)163741008(9106-0008-007F)

Matrix Spike (MS)Laboratory Control Sample (LCS)21 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 163741008 (9106-0008-007F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.22 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 538969 535702 535666 Sample ID 164220002 164220010 1201113887 1201113888 1201113889 1201113890 Client ID 9106-0002-002F 9106-0002-009F Method Blank (MB)163741008(9106-0008-007F)

Sample Duplicate (DUP)163741008(9106-0008-007F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.23 Designated QC The following sample was used for QC: 163741008 (9106-0008-007F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni- 1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 541000 Prep Batch Number: 535702 Dry Soil Prep GL-RAD-A-021 Batch Number: 535666 24 Sample ID Client ID 164220002 9106-0002-002F 164220010 9106-0002-009F 1201118869 Method Blank (MB)1201118870 164220002(9106-0002-002F)

Sample Duplicate (DUP)1201118871 164220002(9106-0002-002F)

Matrix Spike (MS)1201118872 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 25 referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 164220002 164220010 1201106885 1201106886 1201106887 1201106888 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 535984 Client ID 9106-0002-002F 9106-0002-009F Method Blank (MB)163626016(9106-0007-001 F) Sample Duplicate (DUP)163626016(9106-0007-001F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.26 Designated QC The following sample was used for QC: 163626016 (9106-0007-001F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 164220002 164220010 1201107670 1201107671 1201107672 1201107673 EPA EERF C-01 Modified 536336 Client ID 9106-0002-002F 9106-0002-009F Method Blank (MB)164220002(9106-0002-002F)

Sample Duplicate (DUP)164220002(9106-0002-002F)

Matrix Spike (MS)Laboratory Control Sample (LCS)27 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164220002 (9106-0002-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.28 Oualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

29 SAMPLE DATA

SUMMARY

30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0755 GEL Work Order: 164220 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria* Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the reporting limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: 9106-0002-002F Project: YANK01204 Sample ID: 164220002 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector:

Client Moisture:

14.5%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0378+/-0.0665 0.0376 +/-0.0666 Curium-242 U 0.00 +/-0.0752 0.00 +/-0.0752 Curium-243/244 U 0.0331 +/-0.0649 0.00 +/-0.065 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.032 +/-0.0628 0.00 +/-0.0629 Plutonium-239/240 U -0.19 +/-0.124 0.210 +/-0.125 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-9.79 7.84 +/-9.82 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.646 Americitim-241 U 0.0463 Bismuth-212 0.497 Bismuth-214 0.534 Cesium-134 U 0.0362 Cesium-137 U 0.0264 Cobalt-60 U 0.0213 Europium-152 U 0.00263 Europium-154 U -0.00291 Europium-155 U 0.0554 Lead-212 0.703 Lead-214 0.602 Manganese-54 U 0.00163 Niobium-94 U 0.00959 Potassium-40 9.42 Radium-226 0.534 Silver-108m U 0.0101 Thallium-208 0.227 Rad Gas Flow Proportional Counting GFPC, SO 9 O, solid-ALL FSS Strontium-90 U 0.00983 Rad Liquid Scintillation Analysis+/-0.123+1-0.0455+/-0.194+/-0.0856+/-0.0269+/-0.0177+/-0.0149+1-0.0455+/-0.0636+/-0.0468+/-0.0499+/-0.0664+/-0.0184+/-0.014+/-0.696+/-0.0856+/-0.0162+/-0.0424+/-0.0153 0.0498 0.0844 0.113 0.025 0.0185 0.0168 0.016 0.039 0.0464 0.0458 0.0233 0.0272 0.0156 0.0127 0.115 0.025 0.0115 0.014+/-0.123+/-0.0455+/-0.194+/-0.0856+/-0.0269+/-0.0177+/-0.0149+/-0.0455+/-0.0636+/-0.0468+/-0.0499+/-0.0664+/-0.0184+/-0.014+/-0.696+/-0.0856+/-0.0162+/-0.0424 0.165 0.104 0.0897 0.0868 0.506 16.4 0.107 0.174 0.239 0.053 0.0391 0.0353 0.0349 0.0813 0.100 0.0943 0.0481 0.0569 0.0331 0.0269 0.257 0.053 0.0244 0.0296 0.0339 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA 06/22/06 1119 540462 1 1 MXA 06/22/06 1119 540464 2 1 MXA 06/23/06 2100 540465 3 1 MJHI 06/19/06 2034 536186 4 BXF1 06/25/06 1024 539388 5 0.015 +/-0.0153 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: 9106-0002-002F 164220002 Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier R Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U -0.Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -(Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3.84 +/-6.26 5.04 +/-6.26 0461 +/-0.0864 0.0732 +/-0.0864 10.6 pCi/g 0.148 10.2 +/-17.9 13.1 +/-18.0 27.7 4.21 +/-5.83 4.77 +/-5.83 9.82 0.122 +/-0.211 0.182 +/-0.211 0.375 pCi/g pCi/g pCi/g pCi/g NXPI 06/17/06 1642 535984 6 ATH2 06/16/06 0624 536336 7 SLNI 06/21/06 0845 538969 8 SLN1 06/28/06 0021 541000 9 SXEI 06/14/06 1747 536314 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1919 535666 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-l1-RC Modified 3 DOE EML HASL-300, Pu-I1-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-I, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS 92 86 83 77 87 (15%-125%)

(15°/o-125%)

(25%-125%)

(25%-125%)

(15%-125%)

33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-002F Project: YANKO 1204 Sample ID: 164220002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 74 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 83 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-004F 164220004 SE 18-MAY-06 02-JUN-06 Client 17.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.601 0.0156 0.375 0.387 0.0216 0.123 0.119 0.0142-0.0342 0.0127 0.535 0.435 0.0193 6.520E-05 9.32 0.387-0.00653 0.165+/-0.162+/-0.0229+/-0.210+/-0.0828+/-0.0203+/-0.0376+/-0.0405+/-0.0433+/-0.0602+/-0.0398+/-0.0754+/-0.0879+/-0.0241+/-0.0183+/-0.884+/-0.0828+/-0.0164+/-0.0417 0.0507 0.020 0.114 0.0295 0.0192 0.0158 0.0151 0.0394 0.0476 0.0364 0.0224 0.0287 0.0182 0.0154 0.122 0.0295 0.014 0.0157+/-0.162+/-0.0229+/-0.210+/-0.0828+/-0.0203+/-0.0376+/-0.0405+/-0.0433+/-0.0602+/-0.0398+/-0.0754+/-0.0879+/-0.0241+/-0.0183+/-0.884+/-0.0828+/-0.0164+/-0.0417 0.110 0.0411 0.244 0.0624 0.0407 0.0335 0.0333 0.0824 0.104 0.0751 0.0464 0.060 0.0386 0.0327 0.274 0.0624 0.0295 0.0332 0.0408 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/20/06 0609 536186 1 0.0071 +/-0.0176 0.0183 +/-0.0176 BXFI 06/25/06 1025 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1919 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-004F Proiect: YANK01204 Sample ID: 164220004 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-005F 164220005 SE 18-MAY-06 02-JUN-06 Client 18.4%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U7.0 Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.796 0.064 0.621 0.572 0.00 0.198 0.288-0.03-0.0212 0.0189 0.765 0.618-0.0127 0.0223 10.2 0.572)20E-05 0.219+/-0.176+/-0.0949+/-0.246+/-0.107+/-0.0246+/-0.0401+/-0.0484+/-0.0499+/-0.0594+/-0.0589+/-0.0851+/-0.0965+/-0.0192+/-0.0189+/-0.990+/-0.107+/-0.0166+/-0.0403 0.0562 0.0669 0.124 0.0285 0.0212 0.0177 0.0149 0.0428 0.0475 0.0539 0.0266 0.0303 0.0157 0.0136 0.128 0.0285 0.0145 0.014+/-0.176+/-0.0949+/-0.246+/-0.107+/-0.0246+/-0.0401+/-0.0484+/-0.0499+/-0.0594+/-0.0589+/-0.0851+/-0.0965+/-0.0192+/-0.0189+/-0.990+/-0.107+/-0.0166+/-0.0403 0.121 0.139 0.265 0.0607 0.0449 0.0375 0.0329 0.090 0.104 0.112 0.0555 0.0639 0.0338 0.0291 0.287 0.0607 0.0307 0.030 0.0356 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/19/06 2036 536186 1 BXF1 06/25/06 1025 539388 2 0.00701 +/-0.0155 0.0159 +/-0.0155 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1919 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Carrier/Tracer Recovery GFPI Recovery%

Acceptable Limits C, Sr90, solid-ALL FSS 75 (25%-/125%)

37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-005F Proiect: YANK01204 Sample ID: 164220005 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-006FS 164220007 SE 18-MAY-06 02-JUN-06 Client 9.72%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 U Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 Europium-152 U -Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.565 0.0249 0.325 0.508 0.00 0.0576 0.128-0.00196-0.0619 0.0375 0.680 0.599 0.0149-0.00622 10.5 0.508-0.0207 0.239+/-0.182+/-0.0997+/-0.322+/-0.128+/-0.0409+/-0.0404+/-0.0573+/-0.0607+/-0.0812+/-0.075+/-0.0717+/-0.110+/-0.0283+/-0.0219+/-1.02+/-0.128+/-0.0197+/-0.0474 0.074 0.0944 0.178 0.0387 0.0272 0.0227 0.0194 0.0546 0.0613 0.0631 0.0322 0.0396 0.0251 0.018 0.173 0.0387 0.0157 0.0222+/-0.182+/-0.0997+/-0.322+/-0.128+/-0.0409+/-0.0404+/-0.0573+/-0.0607+/-0.0812+/-0.075+/-0.0717+/-0.110+/-0.0283+/-0.0219+/-1.02+/-0.128+/-0.0197+/-0.0474 0.164 0.197 0.387 0.0839 0.059 0.0491 0.0448 0.117 0.139 0.132 0.0677 0.0845 0.0543 0.0394 0.407 0.0839 0.0342 0.0479 0.0306 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/19/06 2036 536186 1 BXF1 06/25/06 1025 539388 2 0.00243 +/-0.0125 0.0135 +/-0.0125 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-/125%)

39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-006FS Proiect: YANKO 1204 Sample ID: 164220007 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0002-007F 164220008 SE.18-MAY-06 02-JUN-06 Client 22.3%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Rod Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U -Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.728 0.0662 0.503 0.582 0.0324 0.381 0.639-0.00433-0.0143 0.0619 0.809 0.690 0.0152 0.00868 12.9 0.582-0.0107 0.238 Uncertainty

+/-0.174+/-0.0842+/-0.246+/-0.0888+/-0.0315+/-0.0456+/-0.0719+/-0.0445+/-0.0575+/-0.0536+/-0.0817+/-0.0992+/-0.0203+/-0.016+/-1.11+/-0.0888+/-0.0149+/-0.041 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0585 0.0732 0.110 0.0274 0.0192 0.0153 0.0156 0.037 0.0475 0.0408 0.0216 0.0263 0.0176 0.0131 0.115 0.0274 0.0127 0.0144+/-0.174+/-0.0842+/-0.246+/-0.0888+/-0.0315+/-0.0456+/-0.0719+/-0.0445+/-0.0575+/-0.0536+/-0.0817+/-0.0992+/-0.0203+/-0.016+/-1.11+/-0.0888+/-0.0149+/-0.041 0.123 0.150 0.231 0.0573 0.0401 0.0321 0.0336 0.0768 0.101 0.0837 0.0445 0.0546 0.0368 0.0275 0.253 0.0573 0.0264 0.0301 0.0298 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/19/06 2036 536186 1 BXFl 06/25/06 1025 539388 2 0.00681 +/-0.0131 0.0131 +/-0.0131.

The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch AXP2 06/02/06 1920 535666 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Carrier[Tracer Recovery Test GFPC, Sr90, solid-ALL FSS Recovery%

Acceptable Limits 81 (25%-125%)

41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Proiect: YANKO 1204 Sample ID: 164220008 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-008F 164220009 SE 18-MAY-06 02-JUN-06 Client 20.9%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium- 134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U-0 Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.574-0.0538 0.294 0.388 0.0325 0.163 0.370 0.0234 0.0429 0.0179 0.584 0.470 0.00381 0.00332 9.79 0.388.000506 0.207+/-0.132+/-0.107+/-0.232+/-0.0771+/-0.040+/-0.0295+/-0.052+/-0.0428+/-0.0592+/-0.0447+/-0.0721+/-0.0851+/-0.0184+/-0.0142+/-0.887+/-0.0771+/-0.0146+/-0.0334 0.0514 0.0921 0.109 0.0245 0.0187 0.0127 0.0129 0.0379 0.0479 0.0428 0.0217 0.0247 0.0158 0.012 0.112 0.0245 0.0131 0.012+/-0.132+/-0.107+/-0.232+/-0.0771+/-0.040+/-0.0295+/-0.052+/-0.0428+/-0.0592+/-0.0447+/-0.0721+/-0.0851+/-0.0184+/-0.0142+/-0.887+/-0.0771+/-0.0146+/-0.0334 0.109 0.191 0.232 0.0518 0.0394 0.0271 0.0283 0.0792 0.103 0.0884 0.0451 0.0519 0.0334 0.0255 0.250 0.0518 0.0275 0.0255 0.035 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/20/06 0610 536186 1 BXFI 06/25/06 1025 539388 2 0.00785 +/-0.0154 0.0156 +/-0.0154 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-/125%)

43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-008F Project: YANKO 1204 Sample ID: 164220009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-009F 164220010 SE 18-MAY-06 02-JUN-06 Client 20.2%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.127 +/-0.168 0.110 +/-0.169 0.318 Curium-242 U Curium-243/244 U Alphaspec Pu, Solid ALL FSS Plutonium-238 U Plutonium-239/240 U -Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 UI Lead-212 Lead-214 Manganese-5 4 U -Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U Rad Liquid Scintillation Analysis-0.0507 +/-0.0445 0.108 +/-0.0449 0.0131 +/-0.136 0.138 +/-0.136-0.0153 +/-0.0792 0.0972 +/-0.0792-0.00835 +/-0.0164 0.0397 +/-0.0164 10.1 +/-12.6 10.1 +/-12.7 0.668-0.0183 0.708 0.520 0.0398 0.184 0.231-0.0209 0.00108 0.00 0.664 0.524 0.00262 0.00538 10.2 0.520 0.0034 0.216+/-0.149+/-0.0763+/-0.214+/-0.0732+/-0.035+/-0.045+/-0.0461+/-0.0407+/-0.048+/-0.0613+/-0.0487+/-0.0743+/-0.0182+1-0.0155+/-0.675+/-0.0732+/-0.0143+/-0.0341 0.0513 0.0635 0.101 0.025 0.021 0.0138 0.0144 0.0355 0.0405 0.0374 0.0199 0.0252 0.0158 0.0134 0.122 0.025 0.0128 0.0145+/-0.149+/-0.0763+/-0.214+/-0.0732+/-0.035+/-0.045+/-0.0461+/-0.0407+/-0.048+/-0.0613+/-0.0487+/-0.0743+/-0.0182+/-0.0155+/-0.675+/-0.0732+/-0.0143+/-0.0341 0.330 0.374 0.289 0.174 21.2 0.110 0.131 0.216 0.0529 0.044 0.0294 0.0316 0.0743 0.0883 0.0774 0.0413 0.0528 0.0335 0.0283 0.271 0.0529 0.0268 0.0306 0.0412 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA 06/22/06 1119 540462 1 MXA 06/22/06 1119 540464 2 1 MXA 06/23/06 2116 540465 3 1 MJH1 06/20/06 0917 536186 4 BXFI 06/25/06 1025 539388 5 0.00294 +/-0.017 0.0184 +/-0.017 LSC, Tritium Dist, Solid-HTD2,ALL FSS 45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: 9106-0002-009F 164220010 Project: Client ID: Vol. Recv.: YANKO 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -Liquid Scint C14, SolidAllFSS Carbon-14 U -0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.-2.65 +/-7.23 6.22 +/-7.23 0114 +/-0.0887 0.0746 +/-0.0887 5.52 +/-16.7 12.3 +/-16.7 4.87 +/-6.73 5.51 +/-6.74 0368 +/-0.224 0.187 +/-0.224 13.1 pCi/g 0.151 25.9 pCi/g pCi/g NXPI 06/17/06 1658 535984 6 ATH2 06/16/06 0757 536336 7 SLN1 06/21/06 0902 538969 8 SLN1 06/28/06 0108 541000 9 SXEI 06/14/06 1804 536314 10 11.3 pCi/g 0.386 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-11-RC Modified 3 DOE EML HASL-300, Pu-11-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-1, Modified 9 DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu 2 4 1, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS 97 92 65 69 98 (15%-125%)

(15%-125%)

(25%-125%)

(25%-/125%)

(15%-125%)

46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-009F Project: YANK01204 Sample ID: 164220010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 67 (25%-125 %)Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0002-OIOF 164220011 SE 18-MAY-06 02-JUN-06 Client 13.5%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.817 0.0037 0.765 0.647 0.0149 0.0661 0.238-0.0245-0.0219 0.0559 0.760 0.736-0.0136 0.0204 10.5 0.647-0.00471 0.285 Uncertainty

+/-0.139+/-0.0906+/-0.247+/-0.103+/-0.0278+/-0.0378+1-0.0552+/-0.0532+/-0.0613+/-0.0498+/-0.0605+/-0.093+/-0.0204+/-0.0198+/-0.808+/-0.103+/-0.018+/-0.048 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0579 0.0728 0.131 0.0322 0.0208 0.0167 0.0158 0.0443 0.0508 0.0482 0.026 0.0315 0.0163 0.0163 0.134 0.0322 0.0148 0.017+/-0.139+/-0.0906+/-0.247+/-0.103+/-0.0278+/-0.0378+/-0.0552+/-0.0532+/-0.0613+/-0.0498+/-0.0605+/-0.093+/-0.0204+/-0.0198+/-0.808+/-0.103+/-0.018+/-0.048 0.125 0.150 0.279 0.0681 0.0442 0.0356 0.0351 0.0928 0.111 0.0993 0.0539 0.066 0.035 0.0345 0.302 0.0681 0.0312 0.036 0.0392 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/20/06 1008 536186 1 BXFI 06/25/06 1025 539388 2-0.0106 +/-0.0136 0.0176 +/-0.0136 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch AXP2 06/02/06 1920 535666 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr9O, solid-ALL FSS 72 (25%-125%)

48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-010F Project: YANK01204 Sample ID: 164220011 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-01IF 164220012 SE 19-MAY-06 02-JUN-06 Client 18%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter r Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actiniun-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 Ul Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.555-0.0836 0.411 0.547 0.00 0.247 0.526 0.0154 0.0336 0.00 0.656 0.634 0.0135 0.0146 11.1 0.547 0.00368 0.227+/-0.154+/-0.106+/-0.209+/-0.0669+/-0.0507+/-0.0433+/-0.0598+/-0.0455+/-0.0642+/-0.0713+/-0.0521+/-0.078+/-0.022+/-0.0161+/-0.820+/-0.0669+/-0.0156+/-0.0428 0.0668 0.0669 0.114 0.0275 0.0177 0.0191 0.014 0.0415 0.0509 0.0413 0.0235 0.0282 0.0192 0.0146 0.123 0.0275 0.014 0.0153+/-0.154+/-0.106+/-0.209+/-0.0669+/-0.0507+/-0.0433+/-0.0598+/-0.0455+/-0.0642+/-0.0713+/-0.0521+/-0.078+/-0.022+/-0.0161+/-0.820+/-0.0669+/-0.0156+/-0.0428 0.142 0.138 0.243 0.0584 0.0378 0.0402 0.0311 0.0868 0.110 0.0853 0.0487 0.059 0.0406 0.031 0.276 0.0584 0.0294 0.0324 0.0333 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/20/06 1009 536186 1 BXF1 06/25/06 1025 539388 2 0.0195 +/-0.0167 0.0147 +/-0.0167 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Carrier/Tracer Recovery GFP'Recovery%

Acceptable Limits C, Sr90, solid-ALL FSS 75 (25%- 125%)50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: 9106-0002-011F 164220012 Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils P0# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-012F 164220013 SE 19-MAY-06 02-JUN-06 Client 18.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter .Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.650 Americium-241 U -0.126 Bismuth-212 0.513 Bismuth-214 0.542 Cesium-134 U 0.0281 Cesium-137 0.175 Cobalt-60 0.118 Europium-152 U 0.0354 Europium-154 U -0.0546 Europium-155 U 0.0313 Lead-212 0.757 Lead-214 0.605 Manganese-54 U -0.0096 Niobium-94 U 0.00277 Potassium-40 10.6 Radium-226 0.542 Silver-108m U 0.00453 Thallium-208 0.291 Rad Gas Flow Proportional Counting+1-0.151+/-0.0935+/-0.177+/-0.0844+/-0.0349+/-0.0364+/-0.0405+/-0.0583+/-0.0598+/-0.0553+/-0.0554+/-0.0866+/-0.021+/-0.0174+/-0.817+/-0.0844+/-0.0174+/-0.0438 0.0574 0.0727 0.112 0.0265 0.0197 0.0164 0.0174 0.0455 0.0448 0.0511 0.0264 0.0296 0.0174 0.0152 0.140 0.0265 0.0149 0.0152+/-0.151+/-0.0935+/-0.177+/-0.0844+/-0.0349+/-0.0364+/-0.0405+/-0.0583+/-0.0598+/-0.0553+1-0.0554+/-0.0866+/-0.021+/-0.0174+/-0.817+/-0.0844+/-0.0174+/-0.0438 0.122 0.149 0.238 0.0561 0.0416 0.0346 0.0376 0.0944 0.0974 0.105 0.0545 0.0618 0.0368 0.032 0.309 0.0561 0.0311 0.0321 0.0297 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/20/06 1009 536186 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00447 +/-0.0108 0.0132 +/-0.0108 BXFI 06/26/06 2133 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-012F Project: YANK01204 Sample ID: 164220013 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldo I-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: 9106-0002-013F Proiect: YANK01204 Sample ID: 164220014 Client ID: YANKOOl Matrix: SE Vol. Recv.: Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector:

Client Moisture:

24.2%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS Actinium-228 0.688 Americium-241 U 0,0271 Bismuth-212 0.421 Bismuth-214 0.662 Cesium-134 U 0.0486 Cesium-137 U 0.0243 Cobalt-60 0.151 Europium-152 U -0.02 Europium-154 U 0.00563 Europium-155 U 0.0391 Lead-212 0.723 Lead-214 0.640 Manganese-54 UI 0.00 Niobium-94 U 0.00857 Potassium-40 10.1 Radium-226 0.662 Silver-108m U 0.00113 Thallium-208 0.289 Rad Gas Flow Proportional Counting+/-0.198+/-0.0326+/-0.302+/-0.100+/-0.0403+/-0.052+/-0.0486+/-0.0504+/-0.0667+1-0.051+/-0.0651+/-0.0947+/-0.0774+/-0.0228+/-0.836+/-0.100+/-0.0192+/-0.054 0.0782 0.0281 0.135 0.0365 0.0255 0.0235 0.0224 0.044 0.057 0.0471 0.0256 0.0361 0.0219 0.0198 0.190 0.0365 0.0169 0.0193+/-0.198+/-0.0326+/-0.302+/-0.100+/-0.0403+/-0.052+/-0.0486+/-0.0504+/-0.0667+/-0.051+/-0.0651+/-0.0947+/-0.0774+/-0.0228+/-0.836+/-0.100+/-0.0192+/-0.054 0.167 0.0577 0.289 0.0772 0.054 0.0496 0.0488 0.0925 0.125 0.0968 0.0532 0.0755 0.0467 0.0418 0.419 0.0772 0.0356 0.0408 0.0276 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/20/06 1010 536186 1 GFPC, Sr90, solid-ALL FSS Strontium-90 U-0.000497

+/-0.0108 0.0122 +/-0.0108 BXF1 06/26/062133 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-013F Project: YANK01204 Sample ID: 164220014 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrierf/racer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-0125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-014F 164220015 SE 19-MAY-06 02-JUN-06 Client 10.5%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier

'Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 UT Cobalt-60 U Europium-152 U -Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 UI Niobium-94 U Potassium-4 0 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U -0.636 0.0288 0.739 0.644 0.0302 0.00 0.00146 0.00893-0.0447 0.0758 0.828 0.740 0.00 0.0196 10.4 0.644-0.0088 0.249+/-0.149+/-0.0915+/-0.253+/-0.0996+/-0.0267+/-0.0443+/-0.0214+/-0.0433+/-0.0542+/-0.0609+/-0.0856+/-0.103+/-0.0228+/-0.0261+/- 1.03+/-0.0996+/-0.0138+/-0.0461 0.0475 0.0757 0.101 0.0268 0.0188 0.0147 0.0183 0.0366 0.0418 0.0408 0.0225 0.0245 0.0149 0.0143 0.119 0.0268 0.0119 0.0144+/-0.149+/-0.0915+/-0.253+/-0.0996+/-0.0267+/-0.0443+/-0.0214+/-0.0433+/-0.0542+/-0.0609+/-0.0856+/-0.103+/-0.0228+/-0.0261+/-1.03+/-0.0996+/-0.0138+/-0.0461 0.103 0.156 0.216 0.0567 0.0398 0.0312 0.0395 0.0767 0.0916 0.0843 0.0467 0.0515 0.0318 0.0303 0.268 0.0567 0.0252 0.0306 0.0406 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/20/06 1018 536186 1 BXFI 06/25/06 1026 539388 2 0.00235 +/-0.016 0.0184 +/-0.016 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier[Fracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-014F Project: YANK01204 Sample ID: 164220015 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-015 F 164220017 SE 19-MAY-06 02-JUN-06 Client 13%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europiun-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-]108m U Thallium-208 Rad Gas Flow Proportional Counting 0.820 0.0169 0.473 0.791 0.00 0.116 0.0507-0.0307 0.075 0.0281 0.886 0.771 0.0219-0.0027 11.9 0.791 0.00556 0.232+/-0.214+/-0.0299+/-0.305+/-0.135+/-0.0379+/-0.0374+/-0.0319+/-0.0547+/-0.0721+/-0.0479+/-0.115+/-0.119+/-0.0304+/-0.0201+/-1.11+Z-0.135+/-0.0176+/-0.056 0.060 0.0251 0.131 0.0338 0.0247 0.0202 0.0175 0.047 0.0658 0.0433 0.0252 0.0334 0.0173 0.0166 0.154 0.0338 0.0155 0.0187+/-0.214+/-0.0299+/-0.305+/-0.135+/-0.0379+/-0.0374+/-0.0319+/-0.0547+/-0.0721+/-0.0479+1-0.115+/-0.119+/-0.0304+/-0.0201+/-1.11+/-0.135+/-0.0176+/-0.056 0.129 0.0514 0.280 0.0713 0.0521 0.0427 0.0385 0A0979 0.141 0.089 0.0521 0.0697 0.0371 0.0352 0.342 0.0713 0.0326 0.0394 0.0405 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/20/06 1019 536186 1 GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.00455 +/-0.0169 0.0179 +/-0.0169 BXFI 06/25/06 1120 539388 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 06/02/06 1920 535666 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 64 (25%-125%)

58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-015F Project: YANKO 1204 Sample ID: 164220017 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 29, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0002-016F 164220018 SE 19-MAY-06 02-JUN-06 Client 19.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 0.973 0.0182 0.682 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 0.800 UI 0.00 0.0731 0.0983 U 0.0105 U 0.0338 UI 0.00 1.01 0.929 U 0.00934 U 0.00509 Uncertainty

+/-0.156+/-0.0728+/-0.202+/-0.0822+/-0.0173+/-0.0225+/-0.0254+/-0.0316+/-0.0361+/-0.0463+/-0.102+/-0.0992+/-0.0177+/-0.0109+/-0.809+/-0.0822+/-0.00976

+/-0.0333 0.0312 0.0685 0.0693 0.0174 0.0121 0.00992 0.0104 0.0267 0.0305 0.0294 0.0157 0.0187 0.00934 0.00939 0.0876 0.0174+/-0.156+/-0.0728+/-0.202+/-0.0822+/-0.0173+/-0.0225+/-0.0254+/-0.0316+/-0.0361+/-0.0463+/-0.102+/-0.0992+/-0.0177+/-0.0109+/-0.809+/-0.0822 LC TPU 0.0651 0.140 0.144 0.036 0.0249 0.0205 0.0218 0.0546 0.0637 0.0598 0.0321 0.0383 0.0194 0.0194 0.185 0.036 0.0176 0.0197 0.0389 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/20/06 1019 536186 1 BXF1 06/25/06 1053 539388 2 MDA Units DF Analyst Date Time Batch Mtd Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 10.5 0.800 0.00238 0.283 0.00854 +/-0.00976 0.00953 +/-0.0333 0.00915 +/-0.0171 0.0173 +/-0.0171 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch AXP2 06/02/06 1920 535666 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (2501.-125%)

60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 29, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-016F Project: YANK01204 Sample ID: 164220018 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.61 QUALITY CONTROL DATA 62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: June 29, 2006 Page 1 of 9 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

164220 Parmname NOM Sample Oual QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 540462 QC1201117598 164220002 DUP Americium-241 Curium-242 Curium-243/244 QC1201117600 LCS Americium-241 Curium-242 Curium-243/244 U -0.0378 Uncert: +/-0.0665 TPU: +/-0.0666 U 0.00 Uncert: +/-0.0752 TPU: +/-0.0752 U 0.0331 Uncert: +/-0.0649 TPU: +/-0.065 13.6 Uncert: TPU: Uncert: TPU: 16.6 Uncert: TPU: U -0.106+/-0.182+/-0.183 U 0.0639+/-0.147+/-0.147 U 0.102+/-0.270+/-0.270 10.3+/- 1.09+/-1.63 U 0.0229+/-0.0607+/-0.0608 15.4+/-1.33+/-2.26 U 0.054+/-0.148+/-0.149 U 0.107+/-0.164+/-0.165 U 0.123+/-0.238+/-0.238 pCi/g 95 pCi/g 200 pCi/g 102 (0%- 100%) vXAI 06/24/06 08:10 (0% -100%)(0%- 100%)QC1201117597 MB Americium-241 Curium-242 Curium-243/244 QC1201117599 164220002 MS Americium-241 Curium-242 Curium-243/244 Uncert: TPU: Uncert: TPU: Uncert: TPU: pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 76 (75%-125%)

06/22/06 11:19 06/22/06 11:19 93 (75%-125%)

13.7 U -0.0378 Uncert: +/-0.0665 TPU: +/-0.0666 U 0.00 Uncert: +/-0.0752 TPU: +/-0.0752 16.7 U 0.0331 Uncert: +/-0.0649 TPU: +/-0.065 U 10.3+/-2.01+/-2.68-0.0497+/-0.257+/-0.257 15.8+/-2.52+/-3.70 75 (75%-125%)

95 (75%-125%)

Batch 540464 QCI201117602 164220002 DUP Plutonium-238 U 0.032 U 0.018 pCi/g 56 (0%- 100%) IXAI 06/22/06 11:19 63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Page 2 of 9 Parmname NOM Sample Oual OC Units RPD%REC% Ranee Anist Date Time Rad Alpha Spec Batch 540464 Plutonium-239/240 QCI201117604 LCS Plutonium-238 Plutonium-239/240 QC1201117601 MB Plutonium-238 Plutonium-239/240 QC1201117603 164220002 MS Plutonium-238 Plutonium-239/240 Uncert: +/-0.0628 TPU: +/-0.0629 U -0.19 Uncert: +/-0.124 TPU: +/-0.125 Uncert: TPU: 12.6 Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.032 Uncert: +/-0.0628 TPU: +/-0.0629 12.6 U -0.19 Uncert: +/-0.124 TPU: +/-0.125 U 8.31 Uncert: +/-9.79 TPU: +/-9.82+/-0.0717+/-0.0717 U 0.018+/-0.0716+/-0.0716 U 0.0504+/-0.0944+/-0.0946 11.2+/-1.19+/-1.67 U 0.00+/-0.0707+/-0.0707 U 0.0462+/-0.104+/-0.104 pCi/g 242 (0%- 100%)(75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 89 (75%-125%)

U 0.0403+/-0.091+/-0.0911 11.2+/-1.17+/-1.63 (75%-125%)

89 (75%-125%)

Batch 540465 QC1201117606 164220002 DUP Plutonium-241 QCI201117608 LCS Plutonium-241 QC1201117605 MB Plutonium-241 140 Uncert: TPU: Uncert: TPU: 142 U Uncert: TPU: U 2.27+/-8.87+/-8.88 117+/-14.6+/-18.8 U -3.1+/-10.1+/-10.1 pCi/g 0 pCi/g pCi/g pCi/g 83 (75%-125%)

06/23/06 22:22 06/29/06 00:04 06/23/06 22:05 (0% -100%) IXAI 06/23/06 21:49 QC1201117607 164220002 MS Plutonium-241 8.31+/-9.79+/-9.82 110+/-13.0+/-16.6 77 (75%-125%)

Rad Gamma Spec Batch 536186 QC1201107353 164220002 DUP Actinium-228 0.646+/-0.123 Uncert: 0.606+/-0.212+/-0.212 pCi/g 6 (0%- 100%) MJHI 06/20/06 10:19 64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Parmname Page 3 of 9 REC% Range Anist Date Time NOM Samole Oual QC Units RPD%Rad Gamma Spec Batch 536186 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.123 U 0.0463 Uncert: +/-0.0455 TPU: +/-0.0455 0.497 Uncert: +/-0.194 TPU: +/-0.194 0.534 Uncert: +/-0.0856 TPU: +/-0.0856 U 0.0362 Uncert: +/-0.0269 TPU: +/-0.0269 U 0.0264 Uncert: +/-0.0177 TPU: +/-0.0177 U 0.0213 Uncert: +/-0.0149 TPU: +/-0.0149 U 0.00263 Uncert: +/-0.0455 TPU: +/-0.0455 U -0.00291 Uncert: +/-0.0636 TPU: +/-0.0636 U 0.0554 Uncert: +/-0.0468 TPU: +/-0.0468 0.703 Uncert: +/-0.0499 TPU: +/-0.0499 0.602 Uncert: +/-0.0664 TPU: +/-0.0664 U 0.00163 Uncert: +/-0.0184 TPU: +/-0.0184 U 0.00959 Uncert: +/-0.014 TPU: +/-0.014 9.42 Uncert: +/-0.696 TPU: +/-0.696 0.534 Uncert: +/-0.0856 TPU: +/-0.0856 U 0.0101 Uncert: +/-0.0162 U -0.00516+/-0.0334+/-0.0334 0.499+/-0.314+/-0.314 0.624+/-0.0957+/-0.0957 U 0.0393+/-0.0379+/-0.0379 U 0.0144+/-0.0255+/-0.0255 U 0.0279+/-0.0414+/-0.0414 U 0.0158+/-0.0602+/-0.0602 U -0.0319+/-0.0859+/-0.0859 U 0.0481+/-0.0651+/-0.0651 0.787+/-0.0603+/-0.0603 0.659+/-0.106+/-0.106 U 0.00979+/-0.0222+/-0.0222 U 0.0335+/-0.0355+/-0.0355 9.25+/-0.703+/-0.703 0.624+/-0.0957+/-0.0957 U -0.00367+/-0.0229 pCi/g 250 pCi/g 0 pCi/g 16 pCi/g 8 pCi/g 59 pCi/g 27 pCi/g 143 pCi/g 167 pCi/g 14 pCi/g I I pCi/g 9 pCi/g 143 pCi/g III pCi/g 2 pCi/g 16 pCi/g 429 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0%- 20%)(0%- 100%)(0%- 100%)(0%- 20%)(0%- 100%)(0%- 100%)Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

164220 Parmname Rad Gamma Spec Batch 536186 QC Summary Page 4 of 9 NOM Samplek Qual QC Units RPD%REC% Range Anist Date Time Thallium-208 TPU: +/-0.0162 0.227 Uncert: +/-0.0424 TPU: +/-0.0424+/-0.0229 0.278+/-0.0495+/-0.0495 pCi/g 20 (0%- 100%)QC1201107354 Actinium-228 Amnericium-241 LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.63 Uncert: TPU: 15.0 Uncert: TPU: Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 U -0.00213+/-0.430+/-0.430 26.5+/-1.24+/-1.24 U 0.0167+/-0.830+/-0.830 U 0.110+/-0.223+/-0.223 U 0.00152+/-0.120+/-0.120 10.6+/-0.401+/-0.401 16.4+/-0.584+/-0.584 U 0.349+/-0.247+/-0.247 U 0.089+/-0.277+/-0.277 U 0.0129+/-0.317+/-0.317 U 0.0378+/-0.159+/-0.159 U 0.0858+/-0.180+/-0.180 U -0.0333+/-0.104+/-0.104 U 0.0477+/-0.104+/-0.104 U 0.103 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 110 (75%-125%)

110 (75%-125%)

113 (75%-125%)

06/20/06 10:20 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 536186 Radium-226 Silver-108m Thallium-208 QC1201107352 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.950+/-0.950 U 0.110+/-0.223+/-0.223 U 0.0477+/-0.0984+/-0.0984 U 0.110+/-0.104+/-0.104 U 0.0667+/-0.0725+/-0.0725 U 0.0113+/-0.0873+/-0.0873 U -0.000464+/-0.101+/-0.101 U 0.010+/-0.0337+/-0.0337 U -0.00516+/-0.0162+/-0.0162 U 0.00559+/-0.0325+/-0.0325 U -0.00201+/-0.0154+/-0.0154 U 0.000846+/-0.0403+/-0.0403 U -7.7 1E-05+/-0.0376+/-0.0376 U 0.00972+/-0.0384+/-0.0384 U 0.0227+/-0.026+/-0.026 U 0.0215+/-0.0287+/-0.0287 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 06/19/06 20:38 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Page 6 of 9 ParmnasmP NflMI Samnle nunal QC Units RPD%REC% Range Anist Date Time Parmname NOM Rad Gamma Spec Batch 536186 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 Rad Gas Flow Batch Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.00138+/-0.0176+/-0.0176 U 0.0168+/-0.0156+/-0.0156 U 0.301+/-0.208+/-0.208 U 0.010+/-0.0337+/-0.0337 U -0.00382+/-0.0128+/-0.0128 U 0.00659+/-0.0142+/-0.0142 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 539388 QC0201114899 164220002 DUP Strontium-90 QC1201114901 LCS Strontium-90 U 0.00983 Uncert: +/-0.0153 TPU: +/-0.0153 U-0.0144+/-0.0118+/-0.0118 1.33+/-0.0832+/-0.0894 pCi/g 0 (0% --100%) BXFI QC1201114898 Strontium-90 MB 1.45 Uncert: TPU: Uncert: TPU: 1.46 U Uncert: TPU: U -0.0105+/-0.0112+/-0.0112 pCi/g pCi/g pCi/g 91 (75%-125%)

06/25/06 11:54 06/25/06 11:54 06/25/06 10:53 06/25/06 10:54 QC1201114900 164220002 MS Strontium-90 Rad Liquid Scintillation Batch 535984 QC1201106886 163626016 DUP Tritium QC1201106888 LCS Tritium QC1201106885 MB Tritium 0.00983+/-0.0153+/-0.0153 1.37+/-0.095+/-0.103 94 (75%-125%)

U 0.738 Uncert: +/-6.97 TPU: +/-6.97 U-1.57+/-7.27+/-7.27 55.2+/-9.22+/-9.27 pCi/g 0 (0% -100%) NXPI 52.7 Uncert: TPU: pCi/g 105 (75%-125%)

06/17/06 17:31 06/17/06 18:04 06/17/06 17:15 U -0.845 pCi/g 68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Page 7 of 9 Parmname NOM Sample Oual OC Units RPD%REC% Range AnIst Date Time Rad Liquid Scintillation Batch 535984 Uncert: TPU: QC1201106887 163626016 MS Tritium+/-5.81+/-5.81 44.6+/-8.62+/-8.66 53.0 U Uncert: TPU: 0.738+/-6.97+/-6.97 pCi/g 84 (75%-125%)

06/17/06 17:47 Batch 536314 QC1201107611 163741008 DUP Technetium-99 QCI201107613 LCS Technetium-99 QCI201107610 MB Technetium-99 QC1201107612 163741008 MS Technetium-99 U 0.196 Uncert: +/-0.227 TPU: +/-0.227 13.1 Uncert: TPU: Uncen: TPU: U 0.273+/-0.233+/-0.233 11.5+/-0.471+/-0.540 U 0.090+/-0.200+/-0.200 11.2+/-0.494+/-0.557 pCi/g 0 (0% -100%) SXEI pCi/g pCi/g pCi/g 87 (75%-125%)

06/14/06 18:37 06/14/06 19:11 06/14/06 18:20 06/14/06 18:54 12.7 U Uncert: TPU: 0.196+/-0.227+/-0.227 88 (75%-125%)

Batch 536336 QC1201107671 164220002 DUP Carbon- 14 QC1201107673 LCS Carbon- 14 QCI201107670 MB Carbon- 14 QC1201107672 164220002 MS Carbon-14 u -0.0461 Uncert: +/-0.0864 TPU: +/-0.0864 U-0.0626+/-0.0867+/-0.0867 7.01+/-0.173+/-0.205 pCi/g 0 (0%- 100%) ATH2 06/16/06 11:05 6.98 Uncert: TPU: Uncert: TPU: 7.03 U Uncert: TPU: U 0.032+/-0.0872+/-0.0872 pCilg pCilg pCi/g 100 (75%-125%)

06/16/06 14:06 06/16/06 09:31 06/16/06 12:38-0.0461+/-0.0864+/-0.0864 Batch 538969 QC1201113888 163741008 DUP Iron-55 QC1201113890 LCS Iron-55 U 21.1 Uncert: +/-18.3 TPU: +/-18.5 U 7.10+/-0.174+/-0.206-1.03+/-16.3+/-16.3 529+/-44.0+/-86.2 101 (75%-125%)

pCi/g 0 (0%- 100%) SLNI 06/21/06 10:23 06/21/06 10:40 575 Uncert: TPU: pCi/g 92 (75%-125%)

69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Page 8 of 9 OC Units RPD% REC% Ranee AnIst Parmname Rad Liquid Scintillation Batch 538969 NOM Samole Oual Date Time QC1201113887 MB Iron-55 Uncert: TPU: U 5.38+/-26.8+/-26.8 pCi/g pCi/g 06/21/06 09:51 06/21/06 10:07 QC1201113889 163741008 MS Iron-55 594 U Uncert: TPU: 21.1+/-18.3+/-18.5 546+/-33.8+/-74.0 92 (75%-125%)

Batch 541000 QC1201118870 164220002 DUP Nickel-63 U 4.21 Uncert: +/-5.83 TPU: +/-5.83 U 3.05+/-5.16+/-5.16 pCi/g 0 (0% -100%) SLNI QC1201118872 LCS Nickel-63 QC1201118869 MB Nickel-63 167 Uncert: TPU: Uncert: TPU: 513 U Uncert: TPU: 149+/-4.20+/-5.46 U 1.39+/-1.55+/-1.55 pCi/g pCi/g pCi/g 90 (75%-125%)

06/28/06 18:29 06/28/06 20:03 06/28/06 17:42 06/28/06 19:16 QC1201118871 164220002 MS Nickel-63 4.21+/-5.83+/-5.83 469+/-13.2+/-19.7 91 (75%-125%)

Notes: The Qualifiers in this report are defined as follows:*A B BD C D H J N/A R U UI X Y A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164220 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.71 Table of Contents General Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

4 Radiological Analysis ...........................................................

7 Sample Data Summary ......................................................

12 Q uality C ontrol D ata ...........................................................

22 IGeneral Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soils PO# 002332 Work Order: 164551 SDG: MSR #06-0819 June 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 164551001 9106-0002-017F 164551002 9106-0002-018F 164551003 9106-0002-018FS 16455t004 9106-0002-019F Items of Note: There are no items of note.GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.P.O. Box 30712 -Charleston, SC-29417 -2040 Savage Road (29407)Phone (843) 556-8171

  • Fax-1843) 766-1178 -www.gel.com Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Four soil samples were analyzed for FSSGAM and Sr-90.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, /NC.P.O. Box 30712 -Charleston, SCJ9417

  • 2040 Savage Road (29407)Phone (843) 556-8171
  • Fax-f843) 766-1178
  • www.gel.com Chain of Custody and Supporting Documentation 4

Health Physics Procedure 11) 1-5h/.-/GPP-GGGR-R5104-003-Attachment B-CY-001 Major ,~., V -I Chain of Custody Form No. 2006-00382 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested abSOnly Contact Name & Phone: Coi.,,. nts -"-Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) --General Engineering Laboratories

-2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c .Priority:

Z 30 D. [] 14 D. [: 7 D. Container Sample Size- -. ;, Media Type &Type Lab ID Sample Designation Date Time Code Code Code Comment, Preservation Lab SampleID 9106-0002-017F 6/2/06 12:49 SE C BP x X Transferred from COC 2006-00378 9106-0002-018F 6/2/06 13:15 SE C BP X X Transferred f-rom COC 2006-00378 9106-0002-018FS 6/2/06 13:15 SE C BP X x Transferred from COC 2006-00378 9106-0002-019F 6/2/06 13:45 SE C BP X X Transferred from COC 2006-00378 NOTES: PO #: 002332 MSR #: 06- 01/ISSWP#

NA Z LTP QA R] Radwaste QA [I Non QA Samples Shipped Via: :Ilnt a[ Fed Ex El UPS ... .em) '.Deg. C E] Hand ý4Custody Sealed?YFn N D 1) Relinquished By Date/Time

2) R d Date/Time o is dySealr,.ý.D y -o Other :.Intaet .3) Relinquished By Date/Time
4) Received by Date/Time
__y.__ .-N D Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time71

/ J 3-r " .. -6)IIW .Receive B rJ 63)A-1

-40 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check -in List Date/Time Received:

-0 ('SDG#: M S (Z- C0(.O, ' 0 i Work Order Number: 2. 0 &Shipping Cdutainer ID:_ --Chain of Custody#-

40A- 0o0,-S;1. Custody Seals. ow shipping container intact?..

Yes No [ ]2. Custody Seals dated and signed? Yes [ j No [4 3. Chain-of-Custody record present? Yes No [ ]4. Cooler temperature ja 0 o 5. Vermiculite/packing materials is: Wet [ ] Dry 6.' Number of samples in shipping container:

7. Sample holding times exceeded?

Yes L,! No (1 8. Samples have:: " ,"tape hazard labels*i custody seals -appropriate sample labels 9. Samples are: in good condition

--leaking broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ]No IL. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:_iD___

_ __ _ Date._ 0 a.-Telephoned to: -On By -6 RADIOLOGICAL ANALYSIS 7 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 164551 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 164551001 164551002 164551003 164551004 1201113174 1201113175 1201113176 EML HASL 300, 4.5.2.3 Dry Soil Prep 538669 537133 Client ID 9106-0002-017F 9106-0002-018F 9106-0002-018FS 9106-0002-019F Method Blank (MB)164551001(9106-0002-017F)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.8 Designated QC The following sample was used for QC: 164551001 (9106-0002-017F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The relative percent difference between samples 1201113175 (9106-0002-017F) and 164551001 (9106-0002-017F) for Bi-214, Ra-226 and Cs-137 did not meet the duplicate criteria.

However, when a relative error ratio is calculated, precision is shown at 1.73 for Bi-214 and Ra-226 and 1.62 for Cs-137.Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to interference.

Europium-155 1201113175 UI Data rejected due to low abundance.

Lead-212 1201113174 Potassium-40 1201113174 Method/Analysis Information 9

Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 541208 537134 537133 Sample ID 164551001 164551002 164551003 164551004 1201119317 1201119318 1201119319 1201119320 Client ID 9106-0002-017F 9106-0002-018F 9106-0002-018FS 9106-0002-019F Method Blank (MB)164551004(9106-0002-019F)

Sample Duplicate (DUP)164551004(9106-0002-019F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 164551004 (9106-0002-019F).

QC Information 10 All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

ZU)(j 0 11 SAMPLE DATA

SUMMARY

12 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0819 GEL Work Order: 164551 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 13 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 6, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

9106-0002-017F 164551001 SE 02-JUN-06 08-JUN-06 Client Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium- 134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.706 0.083 0.404 0.570 0.0448 0.093 0.0807-0.0343 0.00799-0.0483 0.623 0.602 0.00262 0.0223 9.46 0.570 0.00347 0.212+/-0.172+/-0.0774+/-0.291+/-0.101+/-0.0239+/-0.0318+/-0.0343+/-0.0775+/-0.107+/-0.0626+/-0.0817+/-0.103+/-0.0217+/-0.0208+/-0.987+/-0.101+/-0.020+/-0.0455 0.0626 0.067 0.147 0.0369 0.0232 0.0208 0.0197 0.0542 0.0497 0.0548 0.0301 0.0387 0.0192 0.020 0.192 0.0369 0.0174 0.0195+/-0.172+/-0.0774+/-0.291+/-0.101+/-0.0239+/-0.0318+/-0.0343+/-0.0775+/-0.107+/-0.0626+/-0.0817+/-0.103+/-0.0217+/-0.0208+/-0.987+/-0.101+/-0.020+/-0.0455 0.125 0.134 0.293 0.0737 0.0464 0.0416 0.0393 0.108 0.0994 0.109 0.0602 0.0773 0.0384 0.0399 0.385 0.0737 0.0348 0.0389 0.0323 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 1940 538669 1 BXF1 07/05/06 1218 541208 2 0.0214 +/-0.0159 0.0148 +/-0.0159 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B LXM1 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 14 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-017F Project: YANK01204 Sample ID: 164551001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.15 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy.Project: Soils PO# 002332 Report Date: July 6, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

9106-0002-018F 164551002 SE 02-JUN-06 08-JUN-06 Client Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.454 0.0221 0.467 0.431 0.0169 0.0809 0.145-0.0334-0.0109 0.0361 0.493 0.456 0.00174 0.0174 7.48 0.431 0.0126 0.135+/-0.144+/-0.119+/-0.313+/-0.0859+/-0.0277+/-0.0308+/-0.0417+/-0.0666+/-0.0649+/-0.0603+/-0.0723+/-0.0951+/-0.0234+/-0.0216+/-0.906+/-0.0859+/-0.0201+/-0.0457 0.0687 0.0727 0.123 0.0773 0.0237 0.0183 0.0226 0.0497 0.0541 0.057 0.0299 0.0364 0.0208 0.0198 0.164 0.0351 0.0187 0.0187+/-0.144+/-0.119+/-0.313+/-0.0859+/-0.0277+/-0.0308+/-0.0417+/-0.0666+/-0.0649+/-0.0603+/-0.0723+/-0.0951+/-0.0234+/-0.0216+/-0.906+/-0.0859+/-0.0201+/-0.0457 0.137 0.145 0.247 0.155 0.0473 0.0366 0.0452 0.0994 0.108 0.114 0.0598 0.0727 0.0417 0.0396 0.327 0.0702 0.0375 0.0374 0.0251 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/26/06 1941 538669 1 BXFI 07/05/06 1218 541208 2 0.00758 +/-0.0112 0.0114 +/-0.0112 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B LXMI 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 85 (25°/o- 125%)16 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-018F Project: YANK01204 Sample ID: 164551002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamima Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.17 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 6, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

9106-0002-018FS 164551003 SE 02-JUN-06 08-JUN-06 Client Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U -Europium-155 U -Lead-212 Lead-214 Manganese-54 U -Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.634 0.0957 0.422 0.547 0.0511 0.0955 0.325 0.0356-0.00503-0.00931 0.622 0.491-0.00889 0.00212 9.08 0.547-0.00447 0.178+/-0.206+/-0.100+/-0.344+/-0.110+/-0.0335+/-0.0577+/-0.0637+/-0.0743+/-0.0759+/-0.0655+/-0.0818+/-0.112+/-0.0289+/-0.0219+/- 1.02+/-0.110+/-0.0205+/-0.0449 0.071 0.064 0.163 0.0358 0.0264 0.0238 0.0243 0.0529 0.0633 0.0583 0.0315 0.0375 0.0208 0.0194 0.155 0.0358 0.0176 0.0192+/-0.206+/-0.100+/-0.344+/-0.110+/-0.0335+/-0.0577+/-0.0637+/-0.0743+/-0.0759+/-0.0655+/-0.0818+/-0.112+/-0.0289+/-0.0219+/-1.02+/-0.110+/-0.0205+/-0.0449 0.142 0.128 0.325 0.0715 0.0528 0.0475 0.0486 0.106 0.127 0.116 0.063 0.0749 0.0415 0.0388 0.310 0.0715 0.0351 0.0383 0.032 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 2143 538669 1 BXF1 07/05/06 1218 541208 2 0.00242 +/-0.0123 0.0144 +/-0.0123 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B LXMI 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFP(', Sr90, solid-ALL FSS 63 (25%-/125%)

18 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-018FS Project: YANK0 1204 Sample ID: 164551003 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.19 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 6,2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

9106-0002-019F 164551004 SE 02-JUN-06 08-JUN-06 Client Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismnuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.578 0.0776 0.398 0.505 0.0291 0.169 0.121-0.0386 0.0464 0.0138 0.678 0.574 0.0193 0.00219 9.48 0.505-0.0117 0.223+1-0.150+/-0.101+/-0.359+/-0.106+/-0.0514+/-0.051+/-0.055+/-0.0995+/-0.0727+/-0.071+/-0.0907+/-0.134+/-0.0253+/-0.0249+/-1.13+/-0.106+/-0.0232+/-0.0564 0.0742 0.0852 0.182 0.0377 0.0293 0.0241 0.0149 0.057 0.0668 0.0642 0.0344 0.041 0.0237 0.0213 0.175 0.0377 0.0196 0.0193+/-0.150+/-0.101+/-0.359+/-0.106+/-0.0514+/-0.051+/-0.055+/-0.0995+/-0.0727+/-0.071+/-0.0907+/-0.134+/-0.0253+/-0.0249+/-1.13+/-0.106+/-0.0232+/-0.0564 0.148 0.170 0.363 0.0754 0.0586 0.0483 0.0297 0.114 0.134 0.128 0.0687 0.0819 0.0473 0.0426 0.350 0.0754 0.0391 0.0385 0.0406 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/26/06 2144 538669 1 BXFI 07/05/06 1218 541208 2-0.0131 +/-0.0146 0.0187 +/-0.0146 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B LXMI 06/09/06 0758 537134 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 06/08/06 1520 537133 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 65 (25%°-125%)

20 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 6, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-019F Project: YANK01204 Sample ID: 164551004 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.21 QUALITY CONTROL DATA I 22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: July 6, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

164551 Parmname Rad Gamma Spec Batch 538669 NOM Sample Qual QC Units RPD%REC% Ranee Anlst Date Time QC1201113175 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 164551001 DUP 0.706 Uncert: +/-0.172 TPU: +/-0.172 U 0.083 Uncert: +/-0.0774 TPU: +/-0.0774 0.404 Uncert: +/-0.291 TPU: +/-0.291 0.570 Uncert: +/-0.101 TPU: +/-0.101 U 0.0448 Uncert: +/-0.0239 TPU: +/-0.0239 0.093 Uncert: +/-0.0318 TPU: +/-0.0318 0.0807 Uncert: +/-0.0343 TPU: +/-0.0343 U -0.0343 Uncert: +/-0.0775 TPU: +/-0.0775 U 0.00799 Uncert: +/-0.107 TPU: +/-0.107 U -0.0483 Uncert: +/-0.0626 TPU: +/-0.0626 0.623 Uncert: +/-0.0817 TPU: +/-0.0817 0.602 Uncert: +/-0.103 TPU: +/-0.103 U 0.00262 Uncert: +/-0.0217 TPU: +/-0.0217 U 0.0223 Uncert: +/-0.0208 TPU: +/-0.0208 0.584+/-0.130+/-0.130 U 0.086+/-0.0902+/-0.0902 0.381+/-0.154+/-0.154 0.461+/-0.0707+/-0.0707 U 0.0161+/-0.0236+/-0.0236 0.128+/-0.0277+/-0.0277 0.0557+/-0.0288+/-0.0288 U 0.00453+/-0.0324+/-0.0324 U -0.0244+/-0.0402+/-0.0402 U1 0.00+/-0.0492+/-0.0492 0.665+/-0.073+/-0.073 0.566+/-0.0745+/-0.0745 U 0.0196+/-0.0144+/-0.0144 U -0.00792+/-0.0107+/-0.0107 pCi/g 19 pCi/g 4 pCi/g 6 pCi/g 21 pCi/g 94 pCi/g 32 pCi/g 37 pCi/g 261 pCi/g 395 pCi/g 752 pCi/g 7 pCi/g 6 pCi/g 153 pCi/g 420 (0% -100%) MJHI 06/28/06 07:02 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0% -20%)(0%- 100%)(0%- 100%)23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164551 Page 2 of 5 QC Units RPD% REC% Range Anist Date Time Parmname NOM Sample Qual Rad Gamma Spec Batch 538669 Potassium-40 Radium-226 Silver- 108m Thallium-208 9.46 Uncert: +/-0.987 TPU: +/-0.987 0.570 Uncert: +/-0.101 TPU: +/-0.101 u -0.00347 Uncert: +/-0.020 TPU: +/-0.020 0.212 Uncert: +/-0.0455 TPU: +/-0.0455 QCI201113176 Actinium-228 Americium-241 LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.63 Uncert: TPU: 14.9 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: 9.50+/-0.796+/-0.796 0.461+/-0.0707+/-0.0707 U -0.00382+/-0.0103+/-0.0103 0.206+/-0.0277+/-0.0277 U 0.302+/-0.550+/-0.550 22.8+/-3.61+/-3.61 U 0.0874+/-1.12+/-1.12 U 0.180+/-0.242+/-0.242 U -0.0853+/-0.152+/-0.152 9.60+/-0.746+/-0.746 15.7+/-1.16+/-1.16 U -0.199+/-0.337+/-0.337 U 0.0423+/-0.316+/-0.316 U -0.129+/-0.358+/-0.358 U 0.218+/-0.190+/-0.190 U -0.0377+/-0.226 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 06/26/06 21:55 pCi/g 0 pCi/g 21 pCi/g 10 pCi/g 3 97 (75%-125%)

(0%-20%)(0%- 100%)(0%- 100%)(0%- 100%)100 (75%-125%)

105 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164551 Page 3 of 5 Parmname NOM Samole Oual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 538669 TPU: Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201113174 Actinium-228 Americium-241 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.226 U 0.0251+/-0.143+/-0.143 U 0.0304+/-0.109+/-0.109 U 0.367+/-1.28+/-1.28 U 0.180+/-0.242+/-0.242 U 0.120+/-0.123+/-0.123 U 0.0113+/-0.129+/-0.129 U 0.025+/-0.0202+/-0.0202 U 0.0174+/-0.0352+/-0.0352 U 0.0342+/-0.0458+/-0.0458 U 0.00963+/-0.0253+/-0.0253 U -0.00174+/-0.00653

+/-0.00653 U 0.00514+/-0.0129+/-0.0129 U 0.000786+/-0.00617

+/-0.00617 U -0.00965+/-0.0168+/-0.0168 U -0.00089+/-0.017+/-0.017 U -0.00581 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

06/28/06 11:28 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164551 Page 4 of 5 OC Units RPD% REC% Ranee Anist Date Time Parmname NOM Samolle Oual Rad Gamma Spec Batch 538669 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0148+/-0.0148 UI 0.00+/-0.0103+/-0.0103 U 0.0144+/-0.0117+/-0.0117 U -0.00313+/-0.00578

+/-0.00578 U 0.00179+/-0.00587

+/-0.00587 UT 0.00+/-0.0746+/-0.0746 U 0.00963+/-0.0253+/-0.0253 U 0.00355+/-0.00525

+/-0.00525 U 0.00341+/-0.0157+/-0.0157 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Rad Gas Flow Batch 541208 QC 1201119318 Strontium-90 164551004 DUP U -0.0131 Uncert: +/-0.0146 TPU: +/-0.0146 U QC1201119320 LCS Strontium-90 QC1201119317 MB Strontium-90 QC1201119319 164551004 MS Strontium-90

-0.0114+/-0.0131+/-0.0131 1.27+/-0.0859+/-0.0943 pCi/g 0 (0%- 100%) BXFI 07/05/06 12:18 1.38 Uncert: TPU: Uncert: TPU: 2.55 U Uncert: TPU: U 0.00252+/-0.0114+/-0.0114 pCi/g pCi/g pCi/g 92 (75%-125%)

07/05/06 14:24 07/05/06 12:18 07/05/06 14:25-0.0131+/-0.0146+/-0.0146 2.38+/-0.153+/-0.169 93 (75%-125%)

Notes: The Qualifiers in this report are defined as follows: 26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

164551 Page 5 of 5 REC% Range Anist Date Time Parmname NOM Sample Qual QC Units RPD%* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.27 Table of Contents G eneral Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

4 Radiological Analysis ..........................................................

11 Sample Data Summary ......................................................

16 Q uality C ontrol D ata ...........................................................

20 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 167358 SDG: MSR #06-0755 July 25, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on June 02, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 167358001 9106-0002-014FS Items of Note: Based on an email received on July 19, 2006, GEL mistakenly canceled the analyses requested for sample 9106-0002-014FS in the original work order 164220. Upon notification by CYAPCO and subsequent clarification emails, GEL relogged sample 9106-0002-014FS for the requested analyses under work order 167358.2 Analytical Request: One sediment samples was analyzed for FSSGAM and Sr-90.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417

  • 2040 Savage Road (29407)Phone (843) 556-8171 -Fa&843) 766-1178
  • www.gel.com Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Maj or Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00372 362 Injun Hollow Road. East Hampton, CT 06424 860-267-2556

_roject Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only-ontact Name & Phone: Comments: rack McCarthy 860-267-2556 Ext. 3024-nalytical Lab (Name, City, State)3eneral Engineering Laboratories Z040 Savage Road. Charleston SC. 29407 343 556 8171. Attn. Cheryl Jones Ln C?riority:

Z 30 D. [] 14 D. [E 7 D. Container Sample Size-Media Type &Type Sazwple Designation Date Time Code Code Code Comment, Preservation Lab Sample ID)106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364

)106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 106-0002-011F 5/19106 08:10 SE C BP X X Transferred from COC 2006-00365

)106-0002-012F 5/19/06 08:31 SE C BP X x Transferred from COC 2006-00365

)106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365

?106-0002-014F 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365

)106-0002-014FSt, 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365

)106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365

)106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 WOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA fl Non QA Samples Shipped Via: Internal 0 '755 Z Fed Ex Container 4 _Mcvv+ 4t 1 o.'aY, e Yb i0/k/ Da UPS Temp.: C tLaCE L Hand Custody I DyL Sealed?u~he Date/Time

..2) Reived By DatjýTime Custody Seal , /% "- C4(,. [J Other Intact?1) '1elinquished By Date/Time

4) ReceivedBy Date/Time

'Y.___"0_.___

Y-.N N-.__ _*_.__ _ _ Bill of Lading #) Relinquished By Date/Time

6) Received By Date/Time 7O 7 // & t Connect~cut Yankee.Statement of Work for Analytical Lab Services _ ' .. " CY-iSC-Sow-001 Figure 1. Sample Check-in List.Date/Time pRectivedz, 0 (-SDG #: Work Order Number_ (LP.Shipping Custainer d,'hipinC Cut3q .1 Custody Seats orshipping container intact? "Yes No 2. Custody Seals dated and signed? Yes N.o .3. Chain-of-Custo,,y record present? Ye '~s/ No [ ]* 4. Cooler emperature
5. Vermiculite/packing materials is: Wet [ Dry', 0 t 6.' Number of samples in shipping container: " -.-7. Sample. holding times exceeded?

Y No 8. S I hav""ý]L ap h-a" -- . zr labels.custody " -appropriate sample labels 9. Sarmples are.good condition

.l....eaking'-broken -*.....have air bubbles 10. Were any anomalies identified in sample receipt? .Yes [No 9"j*.... .Description of anomalies (include sample numbers):

_ _"_._, S Sample Custodian/Laboratory:.

4.0Dt'Telephoned to: On By .."~~~- B .-."' *""". -
  • SAMPLE RECEIPT & REVIEW FORM"PM use only., ,J n -/" Y ,Client: C r c(4c YA RG C- SDGIARCOC-Work Order: (OZO Date Received:

(,a C$ýo PM(A) Review (ere non-ýconfo ng i rns are resolved prior to signing);

j Received By:j Sample Receipt Criteria Comments/Qualitiers

/ quired for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken/ damaged container leaking container other (describe)

I and sealed? I /_._ _Samples requiring cold Circle Coolant # ice'bags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)? //Record preservation method. /_/Chain of custody documents included with shipment?4 Sample containers intact and Circlpplicable:

seals broken damaged container leaking container other (describe) sealed?Samples requiring chemical Sample UD's. containers affected and observed pH: preservation at proper pH?VOA vials free of headspace Sample ID's and containers affected: 6 (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laborator)

,_ ,_, 8 Samples received within holdin ýl's and tests affected: time?9 Sample ID's on COC matc ID's Sample ID's and containers affected: on bottles? /_10 Date & time on COC tch date Sample ID's affected:& time on bottles? _/Number of container received Sample ID's affected: match number indic/ted on COC?COC form is propirly signed in : "-1relinquished/received sections?

cCc-- Zo -02(-1 Air Bill ,Tracking

  1. 's, &Additional Comments V TRSO RAD Receipt # ____________

e 3 *If > x2 area background is observed on samples identified as "non-p Hr ._ regulated/non-radioactive", contact the Radiation Safety group for further__ __ __ __ L investigation.

A [Radiological Classification?

Maximum Counts Observed*:

'B [PCB Regulated?

Comments: Shipped as DOT Hazardous C jMaterial?

If yes, contact Waste / Hazard Class Shipped:]Manager or ESH Manager. / ON#: PM (or PMA) review of Hazard classiftication:

Initials -Date: -Zj U RE: Missing sample results from GEL (MSR #06-0755)

Subject:

RE: Missing sample results from GEL (MSR #06-0755)From: "Dale Randall" <randall@cyapco.com>

Date: Wed, 19 Jul 2006 09:22:51 -0400 To: "Cheryl Jones" <cj@gel.com>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@

CYAPCO.com>

Cheryl, We would appreciate a short narrative of the corrections for 164220 and an expedited analysis of sample 9106-0002-014S.

Thanks for your prompt attention in helping us resolve this issue.Best Regards, Dale----- Original Message -----From: Cheryl Jones [mailto:cj@gel.coml Sent: Wednesday, July 19, 2006 9:07 AM To: Dale Randall Cc: Clyde Newson; John McCarthy

Subject:

Re: Missing sample results from GEL (MSR #06-0755)Dale, It appears that the direction in Jack's original email was misunderstood.

Talking this situation over with Cheryl Duffy, it's clear that we took his direction to 'withdraw and exclude samples 1, 3, 6, and 16 from analysis' to be our sample IDs and not the location IDs from the COC. In this case, we should have requested clarification and I apologize that we did not. We have the sample container for 9106-0002-014FS and will relog it today for the requested analyses.

Do you need these results expedited?

Also, will you need the narrative for 164220 corrected to reflect the requested cancellation email?Thanks, Cheryl Dale Randall wrote: I You are correct. My notes also indicate that due to a design change, we intended to stop analysis for samples 9106-0002-001F, 9106-0002-003F, 9106-0002-006F, 9106-0002-006FS, and 9106-0002-016F. (Before seeing your notes I was a little confused as to why we have a result for 9106-0002-006FS but not 9106-0002-006F)

In any case, that leaves the result for sample 9106-0002-014FS as missing. Could this sample result be provided?----- Original Message -----From: Cheryl Jones (mailto:cj@gel.com]

Sent: Wednesday, July 19, 2006 8:30 AM To: John McCarthy Cc: Dale Randall; Clyde Newson; Cheryl Duffy

Subject:

Re: Missing sample results from GEL (MSR #06-0755)Jack, The documentation in the package is incomplete.

The COC has a note written on the bottom indicating that the analyses were canceled for several samples at the request of an email received on 6/5/06. The email should have also been included in the package to document the request and this information should have been listed in the Items of 8 I of 3 7 I/2.51065I PMLOD;U I RE: Missing sample results from GEL (MSR #06-0755)I Note section of the package general narrative.

I've attached the email I request for your use. Do you need me to correct the and resend it?Thanks, Cheryl John McCarthy wrote: Cheryl, could you follow up on this?Thank you Jack package narrative*From:* Dale Randall*Sent:* Wednesday, July 19, 2006 7:53 AM*To:* John McCarthy; Clyde Newson*

Subject:

  • Missing sample results from GEL (MSR #06-0755)Jack: MSR #06-0755 does not contain results for samples 9106-0002-006F or 9106-0002-014FS.

We have documentation indicating that the listed samples were received by GEL, but they were not included with results package (either in hardcopy or electronically).

Please query the lab as to their status.Thanks, Dale P.S. Each of these samples is one half of a split, which would be a problem except that we collected an additional split in the second round of sampling.

We thus meet the 5% spilt-sample requirement.

Bottom line: we comply with the FSS requirements, but less justification will be needed if we receive the two sample results that 9 2 of 3 7/25/2006 5:04 PM RE: Missing sample results from GEL (MSR #06-0755)are missing.Cheryl A. Jones Project Manager/PM Team Leader General Engineering Laboratories, LLC 2040 Savage Road Charleston, S.C. 29407 (843) 769-7388 Direct Line (843) 556-8171 x 4243 (843) 766-1178 (fax)The information contained in this message is confidential and is intended only for the use of the individual or firm of record. If you are not the intended recipient and have received this message in error, you are asked not to copy or distribute any of the pages that follow. Please notify the sender immediately by telephone or email if you have received this communication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.10 3 of 3 7/25/2006 5:04 PM RADIOLOGICAL ANALYSIS 11 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 167358 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 167358001 1201139316 1201139317 1201139318 EML HASL 300, 4.5.2.3 Dry Soil Prep 549751 549528 Client ID 9106-0002-014FS Method Blank (MB)167358001(9106-0002-014FS)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167358001 (9106-0002-014FS).

12 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201139317 (9106-0002-014FS) and 167358001 (9106-0002-014FS) were recounted due to high relative percent difference/relative error ratio.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Qualifier Reason Analyte Sample UI UI Data rejected due to a high full-width, half maximum.Data rejected due to low abundance Bismuth-212 Actinium-228 Bismuth-214 Lead-212 Lead-214 Potassium-40 Radium-226 167358001 1201139316 1201139316 1201139316 1201139316 1201139316 1201139316 Method/Analysis Information 13 Product: GFPC, Sr9O, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 549724 549529 549528 Sample ID 167358001 1201139231 1201139232 1201139233 1201139234 Client ID 9106-0002-014FS Method Blank (MB)167358001(9106-0002-014FS)

Sample Duplicate (DUP)167358001(9106-0002-014FS)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167358001 (9106-0002-014FS).

QC Information All of the QC samples met the required acceptance limits.14 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

15 SAMPLE DATA

SUMMARY

16 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO 1 Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0755 GEL Work Order: 167358 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 17 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 26, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-014FS 167358001 SE 19-MAY-06 02-JUN-06 Client 10.6%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter (Rad Gamma Spec Analysis Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.681 +/-0.193 Americium-241 U -0.0046 +/-0.0284 Bismuth-212 UI 0.00 +/-0.385 Bismuth-214 0.502 +/-0.102 Cesium-134 U 0.056 +/-0.041 Cesium-137 U 0.0113 +/-0.0248 Cobalt-60 U -0.00841 +/-0.025 Europium-152 U -0.00306 +/-0.0528 Europium-154 U 0.018 +/-0.0721 Europium-155 U 0.0395 +/-0.0502 Lead-212 0.744 +/-0.0662 Lead-214 0.570 +/-0.100 Manganese-54 U 0.00657 +/-0.0265 Niobium-94 U 0.000605 +/-0.0206 Potassium-40 10.9 +/-1.08 Radium-226 0.502 +/-0.102 Silver-108m U 0.00362 +/-0.0184 Thallium-208 0.241 +/-0.0493 Rad Gas Flow Proportional Counting 0.0749 0.0258 0.155 0.0358 0.0286 0.0224 0.0198 0.0454 0.0629 0.0458 0.0285 0.0325 0.0229 0.0177 0.152 0.0358 0.0169 0.0193+/-0.193+/-0.0284+/-0.385+/-0.102+/-0.041+/-0.0248+/-0.025+/-0.0528+/-0.0721+/-0.0502+/-0.0662+/-0.100+/-0.0265+/-0.0206+/-1.08+/-0.102+/-0.0184+/-0.0493 0.164 0.0536 0.339 0.0773 0.0614 0.048 0.045 0.0969 0.140 0.0954 0.0599 0.0695 0.0498 0.0383 0.358 0.0773 0.0362 0.0418 0.0302 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 07/25/06 1656 549751 1 GFPC, S90, solid-ALL FSS Strontium-90 U -0.007 +/-0.0145 0.0143 +/-0.0145 BXF1 07/24/06 1727 549724 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/19/06 1817 549528 The following Analytical Methods were performed Method Description 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified 18 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 26, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-014FS Proiect: YANK0 1204 Sample ID: 167358001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits CarrierfIracer Recovery GFPC, Sr90, solid-ALL FSS 57 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.19 I QUALITY CONTROL DATA 20 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: July 26, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

167358 Parmname Rad Gamma Spec Batch 549751 NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time QC1201139317 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 167358001 DUP 0.681 Uncert: +/-0.193 TPU: +/-0.193 U -0.0046 Uncert: +/-0.0284 TPU: +/-0.0284 UI 0.00 Uncert: +/-0.385 TPU: +/-0.385 0.502 Uncert: +/-0.102 TPU: +/-0.102 U 0.056 Uncert: +/-0.041 TPU: +/-0.041 U 0.0113 Uncert: +/-0.0248 TPU: +/-0.0248 U -0.00841 Uncert: +/-0.025 TPU: +/-0.025 U -0.00306 Uncert: +/-0.0528 TPU: +/-0.0528 U 0.018 Uncert: +/-0.0721 TPU: +/-0.0721 U 0.0395 Uncert: +/-0.0502 TPU: +/-0.0502 0.744 Uncert: +/-0.0662 TPU: +/-0.0662 0.570 Uncert: +/-0.100 TPU: +/-0.100 U 0.00657 Uncert: +/-0.0265 TPU: +/-0.0265 U 0.000605 Uncert: +/-0.0206 TPU: +/-0.0206 0.688+/-0.228+/-0.228 U 0.0036+/-0.0415+/-0.0415 U 0.329+/-0.419+/-0.419 0.494+/-0.154+/-0.154 U -0.00194+/-0.0372+/-0.0372 U 0.0259+/-0.0314+/-0.0314 U 0.000847+/-0.0418+/-0.0418 U -0.04+/-0.0664+/-0.0664 U -0.00385+/-0.0955+/-0.0955 U 0.0162+/-0.0627+/-0.0627 0.702+/-0.081+/-0.081 0.625+/-0.107+/-0.107 U 0.00559+/-0.032+/-0.032 U 0.014+/-0.0266+/-0.0266 pCi/g I pCi/g 1630 pCi/g 67 pCi/g 2 pCi/g 214 pCi/g 78 pCi/g 245 pCi/g 172 pCi/g 309 pCi/g 84 pCi/g 6 pCi/g 9 pCi/g 16 pCi/g 183 (0%- 100%) MJH1 07/25/06 16:57 (0%- 100%)(0% -100%)(0%- 100%)(0%- 100%)(0% -100%)(0% -100%)(0% -100%)(0%- 100%)(0%- 100%)(0% -20%)(0% -20%)(0% -100%)(0%- 100%)21 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Workorder:

167358 Parmname Rad Gamma Spec Batch 549751 Potassium-40 QC Summary Page 2 of 5 NOM Samnle Oual QC Units RPD%REC% Range Anlst Date Time QC Summary Page 2 of 5 Radium-226 Silver-108m Thallium-208 QCI201139318 Actinium-228 Americium-241 Bismuth-212 10.9 Uncert: +/-1.08 TPU: +/-1.08 0.502 Uncert: +/-0.102 TPU: +/-0.102 u 0.00362 Uncert: +/-0.0184 TPU: +/-0.0184 0.241 Uncert: +/-0.0493 TPU: +/-0.0493 9.58+/-1.11+/-1.11 0.494+/-0.154+/-0.154 0.00577+/-0.0235+/-0.0235 0.227+/-0.064+/-0.064 pCi/g 13 pCi/g 2 pCi/g 46 pCi/g 6 (0% -20%)(0%- 100%)(0%- 100%)(0%- 100%)U LCS Bismuth-214 Cesium-134 Cesium-137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.60 Uncert: TPU: 14.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.0826+/-0.366+/-0.366 25.8+/-2.13+/-2.13 U -0.368+/-0.777+/-0.777 U 0.117+/-0.178+/-0.178 U -0.0432+/-0.0954+/-0.0954 10.2+/-0.911+/-0.911 15.0+/-0.935+/-0.935 U -0.0642+/-0.217+/-0.217 U 0.142+/-0.202+/-0.202 U -0.0245+/-0.304+/-0.304 U 0.056.+/-0.136+/-0.136 U 0.0714+/-0.154 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 110 (75%-125%)

07/23/06 23:03 106 (75%-125%)

102 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Uncert: 22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167358 Parmname Rad Gamma Spec Batch 549751 Page 3 of 5 REC% Range AnIst Date Time NOM Samole Oual QC Units RPD%TPU: Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QCI201139316 Actinium-228 Americium-241 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uneert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.154 U -0.0352+/-0.0898+/-0.0898 U 0.0196+/-0.0827+/-0.0827 U -0.0266+/-0.757+/-0.757 U 0.117+/-0.178+/-0.178 U -0.0296+/-0.0823+/-0.0823 U 0.0283+/-0.0898+/-0.0898 UI 0.00+/-0.0206+/-0.0206 U 0.000573+/-0.0291+/-0.0291 U 0.0249+/-0.0402+/-0.0402 UI 0.00+/-0.012+/-0.012 U 0.00736+/-0.00599

+/-0.00599 U 0.000658+/-0.0128+/-0.0128 U 0.00664+/-0.00569

+/-0.00569 U 0.00871+/-0.0124+/-0.0124 U 0.00596+/-0.0157+/-0.0157 U 0.00413 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

07/23/06 23:02 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167358 Parmname Page 4 of 5 OC Units RPD% REC% Ranee Anist Date Time NOM Sample Oual Rad Gamma Spec Batch 549751 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassiurn-40 Radium-226 Silver-108m Thallium-208 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0126+/-0.0126 UI 0.00+/-0.0091+/-0.0091 UI 0.00+/-0.0108+/-0.0108 U -0.000149+/-0.00597

+/-0.00597 U 0.00445+/-0.00562

+/-0.00562 UI 0.00+/-0.0645+/-0.0645 UI 0.00+/-0.012+/-0.012 U 0.00402+/-0.00406

+/-0.00406 U 0.00908+/-0.0056+/-0.0056 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Rad Gas Flow Batch 549724 QC1201139232 Strontium-90 167358001 DUP U -0.007 Uncert: +/-0.0145 TPU: +/-0.0145 U QC1201139234 LCS Strontium-90 QC1201139231 MB Strontium-90 0.00548+/-0.0205+/-0.0205 1.14+/-0.0482+/-0.0591 pCi/g 0 (0% -100%) BXFI 07/24/06 17:27 1.42 Uncert: TPU: Uncert: TPU: 1.42 U Uncert: TPU: U 0.0153+/-0.0164+/-0.0165 pCi/g pCi/g pCi/g 81 (75%-125%)

07/24/06 17:27 QC1201139233 167358001 MS Strontium-90

-0.007+/-0.0145+/-0.0145 1.37+/-0.0748+/-0.082 96 (75%-125%)

07/24/06 17:27 Notes: The Qualifiers in this report are defined as follows: 24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167358 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.25 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417

  • 2040 Savage Road (29407)Page 2 of 105 Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F Items of Note: At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Seven soil samples were reanalyzed for FSSALL., except gamma and Sr-90.Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.Two soil samples were reanalyzed for FSSALL, except gamma.Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.PO. Box 30712

  • Charleston, SC 29417 ° 2040 Savage Road (29407)Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105.I ý Additional HTD analyses

Subject:

Additional HTD analyses From: "Dale Randall" <randall@cyapco.com>

Date: Thu, 20 Jul 2006 11:04:54 -0400 I (.p 8, LI o q I , (I To: "Cheryl Jones" <cj @gel.corn>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@

CYAPCO.com>

Cheryl: Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol.

I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description:

GEL FSSALL analyses request.xls GEL FSSALL analyses request.xls i Content-Type:

application/vnd.ms-excel Content-Encoding:

base64 Page 4 of 105 IloflI 8/2/2006 7:04 PM flnne Tn be done Done To be done Previous GEL ID ICY samnie location IDs FSS Gain Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 C164220008 9106-0002-007F x x x x x x x x x x o 164220012 9106-0002-011F x _ x x x x x x x x x 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832001 9106-0004-015F x x x x x x x x x x 162485001 9106-0005-010F x x x x x x x x x x 162485011 9106-0005-014F x x x x x x x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 91060010-001 F x x x x x x x x x x 163105016 9106-0010-012F x x x x x x x x x x Chain of Custody and Supporting Documentation Page 6 of 105 kvlaj Health Physics Procedure ffe !K Iq 1) 1ýGPP-GGGR-R5 1 04-003-Attachment B-CY-001 Major Chain of Custody NoForm007 Connecticut Yankee Atomic Power Company No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556

.....cProject Name: Haddarn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 a 843 556 8171. Attn. Cheryl Jones C U , Priority:

Z 30 D. [] 14 D. [-] 7 D. Container 1 40 .A Sample Size- ,_ _Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OO1F 5/17/06 10:42 SE C BP x x Transferred from COC 2006-0o357 9106-0002-002F 5/18/06 09:43 SE C BP x Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP x x Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP x x Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x -'Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X X _ _ Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x x Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP x x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 114:04 SE C BP "x x Transferred from COC 2006-00364 NOTES: P0 #: 002332 MSR #: 06- SSWP# NA [K LTP QA El Radwaste QA E3 Non QA Samples Shipped Via: Internal r 5 Fed Ex Container El UPS Temp.: Deg. C fl Hand Custody Sealed?IRehi -Date/Time

2) 1ý ived By Date/Time Custody Seal e-& --"ý4 ( C\'.;O EOthler Intact?ýýIelinquished B Date/Time
4) Received By Date/Time BillofLading

___Y 11 N O Bill of Lading R 5) Relinquished By Date/Time

6) Received By Date/Time I 17J I Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Healt Phyics roceure PP-GGR-R 10-0 AtahetBCY0 a CD 00 Chain of Custody Form No. 2006-00372 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 5 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: 'Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) General Engineeriag Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones rn Priority:

S] 30 D. [1 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Tr-n-e-e-Comment, Preservation Lab Sample I2 9106-0002-009F 5/18/06 14:28 SE C BP XTrsfrefomC 20-06 9106-0002-00F 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-01IF 5/19/06 08:10 SE C BP x x -Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP X X Transferred frorn-COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X -Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:89 SE C BP x X -Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X X Transferred from COC 2006-00365 NOTES: PO # 002332 MSR #: 06- SSWP# NA Z LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal , Fed Ex Container 0 UPS Temp.: __Deg. C LI Hand Custody Sealed?1 Relin ish Date/Time

2) Re ived By ime Custody Seal COther Intact?3)"Kelinquished By Date/Time
4) Received By Date/Time

_ _ _ _ NO Bill of Lading I 5) Relinquished By Date/Time

6) Received By Date/Time 7qo0 J c Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received:

(0 "? .( g SDG#: c)- 0 -C -" Work Order Number: L L17z( ".Shipping C ,,,tainer IDT, 196_5S /O Chain of Custody*# '() 4, c .') /1. Custody Seals oti shipping container intact?., Yes No[]2. Custody Seals dated and signed? Yes No[]3. Chain-of-Custody record present? Yes No [].4. Cooler temperature

" 5. Verniculite/packing materials is: Wet [ Dry [A 0] (0.Number of samples in shipping container:

_ _ __.'_"_"_7. Sample holding times exceeded?

Yes[] No 8. Samples have: tape _ hazard labels_-_ custody seals __ appropriate sample labels 9. Samples arei..__ ifl good condition

-_leaking-broken -have air bubbles 10.11.Were any anomalies identified in sample receipt?Description ofanomalies (include sample numbers): Yes[, NoX Saample Custodian/Laboratory:

Datez --(--Telephoned to: On*By -Page 9 of 105 Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-O01 Figure I. Sample Check-in List Datedrime Received, "~ t SDG#: A-5 o(Work Order Number: n -OcA' I.Shipping Cdntainer ID.p_ _5720T Chain of Custody#_J)j ( vc'37" S 1. Custody Seals oti shipping container intact?.. -Yes No []2. Custody Seals dated and signed? Yes No [ ].3. Chain-of-Custody record pre.sent? Yes Not].4. Cooler tQmprature.

5. Vermiculite/packing materials is: 'Wet [ Dry 6.: Number of samples in shipping container:

_ _ _ _ _ " 7. Sample holding times exceeded?

.Yes []No~Ji*~A.u~'e~f.8. ts have-:.ae____hazard labels custody seals -appropriate sample labels 9. Samples are:_4 in good condition leaking bbmken ----have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No 11. ..Description of anomalies (include sample numbers): Sample. Custod.ian/Laboratory:

4( ;1- y-Telephoned to:* ___By.Date: Page 10 f;105.

LEN%SAMPLE RECEIPT & REVIEW FORM PM use only Cient:( l , , P SDG/ARCOC/Work Order: I (A(220 IDate Received:

&R a J QPM(A) Review (eisure non-conforming items are resolved prior to signing);Received By: GIj Sample Receipt Criteria CommentslQualifiers (Required for Non-Conforming Items)I ýShipping containers received intactl >.1Circle, Applicable:

seals broken damaged cnaerI container offir (describe) and sealed? 7 Samples requiring cold Circle Coolant # ice bags blue ice dry ice none other describe)2 preservation within (4 +1!- 2 C)?-Record preservation method.3.Chain of custody documents included with shipment?

intactand__,___/___

S ample containers intact and ite Applicable:

sdS broken damaged container leaking container other (descrile) 4 sealed? I I Samples requiring chemical Spa p 'IDs. containers affected and observed pH: preservation at proper pH? Z VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

Samples received wi holding Id's and tests affected: time? /SSample ID's OC match ID's Sample ID's and cornainers affected: on bottles?1 -Date & on COC match date "ample IS affected!& ti on bottles?Nu ber of containers received Sample IU's affected: match number indicated on COC?COC form is properly signed in 12rlnusc/reccived sections? 14Air Bill ,Tracking

  1. 13 &Additional Comments e RSO RAD Receipt #Suspected Hazard Information

' .= *If > x2 area background is observed on samples identified as "non-Z regulated/non-radioactive,, contact the Radiation Safety group for further Sinvestigation.

A Ra c a Maximum Counts Observed*:

Us.a Pag a of ents: hippd asDOT' Haardus cMaterial?

It" yes, contact Waste Haad Class Shipped:---.Manager or ESH Manager. J N#: PM (or PMA) review of Hazard ]lass Inin""irtials Page I11 of 105 (0G l SAMPLE ]RECEIPT & REVIEW FORM 0" PMus ol SClient: YZ -n re C_ [SDGIARCOC1W~k Order:_ &. 4'ZZOprotosrn:

Date Received:

c C)v 0 PM(A) Review ( e non-confor

  • areg esovd ior to signing): Received By: MI Sample Receipt Criteria ; z Comments/Qualifiers equired for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broke damnaged container leaking container other (des.cribe) 1 and sealed? __ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _Samples requiring cold Circle Coolant # icyfags blue ice dry ice none other describe)preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?Sample containers intact and Cr licable: seals broken damaged container leaking container otier (describe) sealed?5 Samples requiring chemical Sampe ID's. containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample 1D's and containers affected: (defined as < 6mm bubble)? .....Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

_ ,I,_, Samples received within id's and ,ests affected, time?9 Sample ID's on COC matc ID's Sample ID's and containers affected: on bottles? /Date & time on COC tch date Sample ID's affected:& time on bottles? _Number of containe received Sample ID's affected: match number indic-ted on COC?COC form is propirly signed in .4-'1relinuished/rEgived sections? Z-0C)p oal' -t- 1(4.Air Bill ,Tracking

  1. 's, &Additional Comments W- RSORAD Receipt # ___________

d Ht -*I > x2 area background is observed on samples identified as -non-Suspected

_ regulated/non-radioactive", contact the Radiation Safety group for further_ __ investigation.

A Radiological Classification? , Maximum Counts Observed*: , -,/n SPCB Regulated?

Comments: Shipped as D)01 HazardJous-c Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

Initials -g(-7A 0(o Page 12 of 105 U Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major~Chain of Custody Form No. 2006-00312 Connecticut Yankee Atomic Power Company 2. ~362 Injun H-ollow Road, East Hampton, CT 06424/860-267-2556 UL 1,j4 /&,2335 5/4/ '0 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only.--Contact Name & Phone: IComents: Jack McCarthy 860-267-2556 Ext, 3024 Analytical Lab (Name, City, State)General Engineering Laboratories

< 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn Priority:

0 30 D.E[] 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample.ID-9106-0003-OO1F 4/24/06 14:13 SE C BP X Transferred from COC2006-00221 il' 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221 p) 9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223 9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223 9106-0003-007F 4/25/06 10:28 SE C BP X "transferred from COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP X Transferred from COC2006-00223 NOTES: PO #: 002332 MSR #: 06- , SSWP# NA Z LTP QA El Radwaste QA C1 Non QA Samples Shipped Via: ..nterna, CoQpht~r.er Combined sampies 9106-0003-003F taken on 4/25/06 @09:19 and 9106-0003-003FB taken on 4025/06@ 08:19 in order to have sufficient sample for counting.

E Fed Ex !Tetpi*..:::

'..DegeC E] U PS

.' ..,.": 0I Hand Custody Sealed 9.1) Relinquished By Date/Time

2) -ived By _ t ie*isoySa nat/-______________.__,_y_--______.330 , f1 Other 3) Relinquished By Date/Time
4) Received By Da/Time _______________Y
l N -Bill of Lading .5) Relinquished By Date/Time
6) Received By Date/Time

.92O- 9,,O-O2 4 "

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-001 Major (r Chain of Custody Form No. 2006-00313 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

-,-Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: r Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) .. .General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 ...843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D.[ 14 D. 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code -- 7Comment, Preservation

-.,,. ..toAi 9106-0003-009F 4/25/06 13:00 SE C BP X -Transferred from COC 2006-00236

'. ..0A 9106-0003-010F 4/25/06 13:23 SE C BP X TransferredfromCOC2006-00236 0 9106-0003-O1OFS 4/25/06 13:23 SE C BP x Transferred from COC 2006-00236 9106-0003-012F 4/25/06 15:12 SE C BP x Transferred from COC 2006-00236 S9106-0003-012F 4/25/06 14:121 SE C BP x- -Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP X Transferred from COC 2006-00236 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred from COC 2006-00236 OR 9106-0003-015F 4/26/06 08:16 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP x Transferred from COC 2006-00237

-9106-0003-018F 4/26/06 08:59 SE C BP X Transferred from COC 2006-00237 .J "'Y. , NOTES: PO #: 002332 MSR #: 06- Os SSWP#NA 0 LTP QA[I Radwaste QA[] Non QA 1) Relinquished By Date/Time

2) fReceived By D Date//Time
3) Relinquished By Date/Time
4) Received By rDaC/Time Samples Shipped Via: Z Fed Ex El uPs El Hand El Other Bill of Lading #75120-Z'1-20/-

o2,d..T~eer 4De C!N'yso 6 Jd?.b'td~_J;I; Y-t~4N ux,." /Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

t (.0I SDG#: j46j 'Work Order Number: .I tceZ-3 Shipping cdntainer ID: "-l wqlf 'zi ) 0_7Ci f IChain of Custody# ( )(Yo 003'i 1. Custody Seals off shipping container intact?. Yes t ] No 2. Custody Seals dated and signed7 Yes [ ' No 3. Chain-of-Custody record present? Yes No [].4. Cooler temperature C 1 I C.-5. Vermiculite/packing materials is: 'et [ Dry [ n] '__-_!__:_

6.' Number of samples in shipping container:

[t e- Ea t[ 7 r'- ri L 7. Sample holding times exceeded?

Yes [ I No.8. Sampleh :'tae -hazard labelscustody seals -appropriate sample labels 9. Samples are-good condition jleaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No I.. =Description of anomalies (include sample numbers):.amnple.Custodian/Laboratory: ( ,f>( &'. cc'C. -Telephoned to: On By Page 15 of 105 SAMLERECEIPT

& REVIEW FORM NflAR0 Mn 8 Client: q '-fl 1516 SDG/ARCOC/Work Order: Received By: T2 737-r' C a 4 _ _ _ __ _ _ _ __ _ _ _ _Sample Receipt Criteria Comments/Qualiriers (Required for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) and sealed? _ _ _ _ _ __ _ _Samples requiring cold Circle Coolant # ice bags blue ce dry ice oe 2 preservation within (4 +/- 2 C)? P ru Record preservation method. -P n__ __ _ _ _Chain of custody documents included with shipmi.ent?

4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking comainer odter (describe) sealed?Samples requiring chemical Sample ID's, containers affected and observed pH: reservation at proper pH?VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)? _Are Encore containers present?7 (If yes, immediately deliver to VOA laborato!y) 8 Samples received within holding Id's and ws af .time?Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?Date & time on COC match date Sample D's affee:& time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in relinquished/received sections?Air Bill ,Tracking

  1. 's, & q .d --Additional Comments OVA O -- (RSO RAD Receipt#Suspected Hazard Information

""If > x2 area background is observed on samples identified as *non-Z 11 *regulated/non-radioactive", contact the Radiation Safety group for further C4 investigation.

A J adiological Classification?

Maximum Counts Observed*:

B rPCB Reguat? Comments: Shipped as )Uu rHazardous C IMaterial?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. 1 1 , PM (or PMA) review of Hazard classification:

Initials & .- Date: o 0 1 Page 16 of 105 1 1.

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY- 001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 ,Vontact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r,, Priority:

E 30 D. [] 14 D. []:7 D.Samples Shipped Via: 0 Fed Ex El uPs C] Hand nl Other Bill of Lading #

Phys~s Pro~edure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major SCQnIul Yankee Atomic Power Company S".61hjun Hollow Road, East Hampton, CT 06424 860-267-2556 Contact Name & Phone: Jack McCarthy -` 860-267-2556 Ext. 3024 m E Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road.Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

M 30 D. [] 14 D. I 7 D.Date Samples Shipped Via: Z Fed Ex EuPS El Hand Ml Other Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List 1 .20 Datc/Timric Receivcd:

,.)_ 0 G.SDG#: AIc5R-O4-O&FF Work Order Number: /Shipping Container ID: q-3 315- 8g 1. Custody Seals on shipping container intact?2. Custody Seals dated and signed?3. Chain-of-Custody record present?4. Cooler temperature

5. Vermiculite/packing materials is: 6. Number of samples in shipping container:
7. Sample holding times exceeded?tj'~Chain of Custody # Oo/, -60T5o, 1 Yes No []Yes No []Yes No [],'14/Wet Y Dry [ )CI.Yes [] No V 8. Samples have: k.tape hazard labels_ custody seals appropriate.sample labels 9. Samples are:_ in good condition

__4 leaking broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes No []1I. Description of anomalies (include sample numbers): Sample Custodian/Laboratorya r AI t._,.Telephoned to: On Date: J, 0~ d~B Y.Page 45 of 56 Page 19 of 105 Connecticut Yankee Statement of Work for Analytical Lab Services MCYISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received:

a ( AL*SDG#: Work Order Number: 3-7-.ShippingCtaataiter IDe Chain of Custody# *k jOo,, -n0334 I. Custody Seals on shipping container intact?.. -Yes. ] No [e3)2. Custody Seals dated and signed? Yes'[ ].No f4 '3. Chain-of-Custo.iy rocord present? Yea N [No 4. Cooler emperature I ' .5. Vermiculite/packing materials is: Wet [-?0Diry JVt 6: Number ofsamples in shipping container

_ _"_J_ _, 7. Saaple hoding times xceeded?.. .: Y e s [ ] N o ]8.. Sampl have:--".ta _..-hazard labels-.o!..4Mu6dy seals -. appropriate sample labels 9. Samples amr:.__.in good condti~on

,.r-"- broke " ." " ihave air bubbles 10. Were any anomnalie identified in samýe receipt?.

Ye N Desripi Ion ofYes W No J .. .D iption of aniomalies (lnclude sample numbers):

i 1>j h......" S-amPleCustodian/Labor " ..T elepho ned tO,: _..Ry___..___,__Date.

Teeboe to.

' .Page 20 of 105 i r

~-'0 N'SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM_27,C _ qq__O £, +/- 4C0( "n'r, 1--- -- Coto I U21t 0o)- 3i) S)V(-loII5 '-Oc "hS) (" (a ) _Swi-1-i (I35 cag I a 1-~ A~bn 0017 9ý3l- o31i s ccv-ri_.v h\cad 4" bLL5fec L1y o6 ue , l.r.v4i of ..Page 21 of 105 I 1 ! 1 5 SAMPLE RECEIPT & REVIEW FORM a PM me only Clint C4ý YLI SDG/ARCOCIWork Order: /4'?Y ~3 Date Received: , (A) Review (ensure non-conforming items are resolved prior to signing):[Seeved By: , A.,t'/h ._ _ ._ _ _ _ _ _ _ __. ...Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)1 Shipping containers received intact ircle Applicable:

seals broken damaged container leaking container other (describe) and sealed? r Samples requiring cold Cirle Coolant # ice bags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)?-Record preservation method.Chain of custody documents 3included with shipment?

a 4 Sample containers intact and Crle Applicable:

seals broken damaged container I othr(describe) sealed? 910. 0I -ODDo .-- 0 p " 5 Samples requiring chemical Samnple Ms. containers affeeted and observed pH:-preservation at proper pH?VOA vials free of headspace Sample ID's and containers affected: 6 (defined as < 6rm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

_ _ _ _ _. ....8 Samples received within holding Id'S and tMtS aected: time?9 Sample ID's on COC match ID's Sp ID's and conins affected: on bottles?Date & time on COC match date Sm ID's affected:& time on bottles? _Number of containers received S amte D's affcted: 11 match number indicated on COC?12 COC form is properly signed in relinfqushed/received sections?

__ C-. A-* 4 -" 6,#.,S 6&14 Air Bill ,Tracking

  1. 's, &Additional Comments..RADI Receipt-4 ; gj*If > x2. area background is obsered on samples identifiedason s ed r Inormation ulated/non-radioactive, contact the Radiation Safety group for'further A Radiological Clamific~tion?
________________Maximum Counts Obseved*:

<n IPCB Reglate-?:

-d i. M as L"IrHa-aaous

-, , , , C Material?

If yes, contact Waste azardClam Shipped: Manager or ESH Manager. y oN:-P/AabP2!*qjw of Hazard classification:

Initials Date: s--/7406;,*/

0 SAMPLE RECEIPT & REVIEW FORM.0 PhM use onlylClient. 14nn i 'SDGARCOC/Work Ordr: /6 Z r 2-, IDate Received:

c PM(A) 1e ( heaw m resolved priw to signing): Received By: (2 Qel ( i __+e,)_Sample Receipt Criteria Comments/Qualrflers (Required rot Non.Conforinng Items)1 Shipping containers received intact cile Applicable:

seals broken damaged co.t-iner leaking con-aiafr other (describe) and sealed? ... ...... _ _ _ _ _ , Samples requiring cold Circk Coolmat I ice bags blue kce dry Ice ( other describe)2 preservation within (4 +/- 2 C)? .Record vreservation method. 110 C'Chain of custody documents -C0 CU,& Dx b \tj C+included with shipmenI?

/4 Sample containers intact and T.t:PP, : sa)$ b i doena Cuflt *fC Ickng com ter sealed? Ctt Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH? ... .........6 VOA vials free of headspace-(defined as <6mm bubble)? ._._Are Encore containers present? ,, 7 (If yes, immediately deliver to VOA r-)__ __ _ _Samples received within holding Id's and L-st ia:fcted time?Sample ID's on COC match ID's Sample ID's amn etaamnes affected: on bottles?Date & time on COC match date Sample lD's affected:& time on bottles?Number of containers received Sample IDs affected: match number indicated on COC?COC form is properly signed in "it " c- '- vLu relinquished/received sections?

............

14 Air Bill ,Tracking

's, & C 0 Sh6e.+-Additional Comments T [RSO RADReccipt_#

Sq *If > x2 areabackground is observed on samples identified as "non-Sspected Hazard Information U 5 f regulated/non-radioactive".

contact the Radiation Safety group for firtwer ad investigation.

A Radiological Classification?

-]xium Counts Observed:t r ..PC gulatd?Comments:

Shipped as DOT Hazardous Material?

If yes, contact Waste Hazard Class Shipped: M Manager or 1 Manager.UNI:

PM (Owof Hazardclassication:

Initials 1C,- Date: .ura -3 0I IUj Y4 Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-O0 ~ Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 1 Project Name: Haddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

2 30 D. [] 14 D. E- 7 D.Samples Shipped Via:[ Fed Ex[luPs C1 Hand n] Other Bill of Lading #7'q&2 1,9.6" Connecticut Yankee CY-lSC-SOW-01 Statement of Work for Analytical Lab Services .., * ,jS..-O -Figure 1. Sample Check-in ListwL, Dateflime Received:

51'IIU SDG,*Work Order Number: LA Shipping Cof~tainer ID: ; " 57J -Chain of Custody # ",2, b 0O. l ( / t* 1. Custody Seals owi shipping container intact? -Yes No[" 2. Custody Seals dated and signed? Yes' jfNo [.3. Chain-of-Custody record present? Yes JP.4 No I ]4. Cooler temperature Igo(/ .-9 -* 5. Vermiculite/packing materials is: 'Wet t.4Dry [,]6. -Number ofsamples in shipping container:

_7. Sample holding times exceeded?

Yes NO No 8. Samples have:'LJtape .hazard labels_.Zcustody seals -appropriate sample labels 9. Samples are: in good condition

-2IeAkirg (Sill&e' 4~S broken -have air bubbles 10. Were any anomalies identificd in sample receipt? Yes 'I No [.,]11. Description of anomalies (include sample numbers): Telephoned to: On By Page 25 of 105*

SAMPLE RECEIPT & REVIEW FORM ff PM oe only Client: SDGIARCOCIWork Order: HI GZ-8Date Received:

t PM(A) Review (ensure non-conro ug items are resolved prior to signing): Received By: Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)',,Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container ofter (describe)

Iabcsealed?

, Samp requiring cold Circle Coolant # ice bags blue ice dry ice none oler describe)2 preservat within (4 +/- 2 C)?Record 3reserv on method. .Chain of custody d '8 s 3 ?_included with shi ment?4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking conmainer other (describe) sealed?Samples requiring chemical Sample 'JIs. containets affected and observed pH:-p r e s e r v a tio n a t p r o p e r p H ? S _ le _I D _sand_ _ _ _ _ _ _ _ _ _ _ __aff ected : 6 VOA vials free of headspace.Sample ID's and coainers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)"6Lt.

..Samples received within holding id's aid te afected.8.time?9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?10 Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?12lCOC form is properly signed in 1relinquished/received sections?14 Air Bill ,Tracking

  1. 's, & F1 ' -4?5'2- -> /7 --Additional Comments IRA #2499 -,->RSO RAD Receipt #mat_1 c *If > x2 area background is observed on samples identified as *non-Suspected Hazard Information Z -p regulated/non-radioactive", contact the Radiation Safety group for fuirther 04. l : investigation.

kA Radiological Classification?

-Maximum Counts Observed*:

B Full Regulated?

Crucns fShipped as DXYI'Hazardous Material?

If yes, contact Waste Hazard Class Shipped: IManager or ESH Manager. UN#PM (or PMA) review of Hazard classification:

Initials Date: 75 ,ra gic 26 o f I6 ... .. .g Y/

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company ..,* ..362 Injun Hollow Road, East Hampton, CT 06424 a .860-267-2556

ýfroject Name: Haddam Neck Decommissioning

-Analyses Requested MI .ýContact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 K, Analytical Lab (Name, City, State) .General Engineering Laboratories

.4 2040 Savage Road. Charleston SC. 29407 '843 556 8171. Attn. Cheryl Jones cn Cn Priority:

[ 30 D. [ 14 D. [ 7 D. Container

-.. , ,___________

____Sample Size- 4 Media Type &Type W4 Sample Designation Date Time Code Code Code Comment, Preservation 9106-0006-004F 4/28/06 12:46 SE C BP X X Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP x x Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X X -Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP x x- Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP X X Transferred from COC 2006-00317 9106-0006-012F 4 5/21/06 13:40 SE C BP X X Transferred from COC 2006-00317 9106-0006-017F, 5/01/06 14:03 SE C BP X x Transferred from COC 2006-00317 NOTES: PO #: 002332 MSR #: 06- t4%1 SWP# NA M LTP n A r7 Q A M Non f-,A Samples Shipped Via: LI Fed Ex CHand 1) Relinquished By Date/Time

2) Received By ( "ate/Time 3) Relinquished By Date/Time
4) Received By 1 late/Time Bill of Lading #ýL wo- ?.ffo-4/ y Connecticut Yankee CY-ISC-SOW-O01 Statement of Work for Analytical Lab Services ..S -Figure 1. Sample Check-in List Datfime Rccived: " .*SDG#: Work Order Number ShippingCdiltainer ID: Qt Chain of CustodY# .&'1. CustodySeals ozshipping container intact?.: -Ys s No(_kD 2. Custody Seals dated and signed? Yes No 3. Chain-of-Custody reord present? Yesk).No [I I..4. Cooler temperature

.1_5 * .we ."r 5. :Vermiculite/packing materials is: Wet ) Dry [' ]6. : -Number of samples in shipping containor 7. Sample holding imes exceeded?

Yes [ No t14.8. Samples have-__ape haz~ard labels-J cstd se~ _approprateo sapllbels 9. ,Samples am' .good condition leaking brokn .-." have air bubbles 10. Were any anomalies identified in sample rCeipt?" Yes [ No 11. .Description of anomalies (include sample numbers): Sample Custodia./Laboratory: ,_ Date:/7 Telephoned to:0 .. " Page 28ofl105 SRECEIPT & REVIEW FORM-e4ORf iPM n only Chient:

rder: &Z r3"Z, Date Received:

t:5-/ ýPM(A) Review (jue ncofalonn Ite1M uwe reolved prior to signag): eceived By: C .. .Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)Shipping containers received intact ircie Applicable:

seals broken damaged conminer leaking container ofier and sealed? ......Samples requiring cold Circle Coolant # ice bags blue ice dry iCC c other descmr)2 preservation within (4 +-A 2 C)?Record preservation method. o0 C.Chain of custody documents COU S O-x 0 \tN L+included with shipment?Sample containers intact and damagedconuiner lakingcoaiwr ocscribc)sealed? _0~.t~M. ~ qg'cIKQ~Samples requiring chemical sa,,ic ID's. co,.aim affcccd and observed pH: 8q preservation at proper pH?VOA vials free of headspace ISanle ID' and containers affected: (defined as < 6mm bubble)? I Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

.....8 Samples received within holding Id's a t affece: time?Sample ID's on COC match ID's le ID's wad conasmiers affectedt on bottles?Date & time on COC match date Sanple ID's affected:& time on bottles?Number of containers received s,,,e W's match number indicated on COC?COC form is properly signed in ( CbeQs OL, Yuq-, rVAj 3 .C1 relinquished/received sections? .I_Air Bill ,Tracking

  1. 's, & c. C. c y () I'JLL..Additional Comments IV' RSO RAD ReciptI___________

Suspected Hazard Information R p *If > x2 area background is observed on samples identified as -non-Vd regulated/non-radioactive'.

contact the Radiation Safety group for further Radiological Class/ficatiMn?

aximum Counts Observed*:

PCU Regulated?

Comments: fShipped as D0 I Hazardous ClMaterial?

If yes, contact Waste /Hazard Class Shipped: Manager or ESH Manager. UN#: I PM (or PMA) review of Hazard classification:

Initials O-/ Date a U* .JLIL].V/

I SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM-______________

~ U1-o S00u((91055 09,0t~ O53O 6 (0~ y-qqiq~00L(

nta, (h5.C je-3eJ haxcd m bt~sitd 5aM,_ __ __ __k_c ---- et S-('_4_bast _.d_ a~rnI Page 30 of 105'1 T." 11 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major CD 04 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00367 362 Injun Hollow Road, East Hampton, CT 06424 /'/Nae adanNc 860-267-2556 - -Lab Use Only Project Name: Hddam Neck Decommissioning Analyses Requested Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Aftt. Cheryl Jones C4 4 , t z Priority:

Z 30 D. [ 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-001F 5/05/06 11:13 SE C BP X X X Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP X X x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X x x Transferred from COC 4 2006-00325 9106-0008-007F 5/5/06 15:03 SE C 13P X Transferred from COC # 2006-00325 9106-00 08-002F 5/5/06 13:10 SE C BP x x x Transferred from COC # 2006-00325 NOTES: PO 4: 002332 MSR#: 06- )7q3 SSWP#NA N LTP QA E3 Radwaste QA E] Non QA[E i I /1) elinqu sh Date/Time

2) e ive Ya m 3) inquished By Date/Time
4) Rdeeiveu Vy ate/Time aamples Shipped Via: 5; Fed Ex-uPs-Hand] Other 3ill of Lading #Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YO NO I Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-00366 MConnecticut Yankee Atomic Power Company W362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 11o3-7 41 V.Project Name: H{addam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 5.843 556 8171. Attn. Cheryl Jones En Z Priority:

N 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Comment, Preservation Lab Sample ID Sample Designation Date Time Code Code Code tJ) 9106-0008-008F 5/08/06 08:01 SE C BP X -X Transferred from COC # 2006-00327

_0 9106-0008_-009F 5/08/06 08:32 SE C BP x x x Transferred from COC # 2006-00327 oil 9106-0008-010F 5/08/06 09:09 SE C BP X X X Trans-fedfrom COC_#2006-00327-01I 91060008010F 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 OIL 9106-0008-01OFS 5/08/06 09:0 SE C BP x X X Transferred from COC # 2006-00327)It 9106-0008-01 IF 5/08/06 09:30 SE C 13P x ___ x x Taserdfo C 20-02 I1 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC # 2006-00327 9106-0008-013F 5/08/06 10:16 SE C BP X x x Transferred from COC # 2006-00327

ý5 9106-0008-014F 5/08/06 10:47 SE C BP x x x Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 67q3 SSWP# NA 0 LTP QA fl Radwaste QA [I Non QA Samples Shipped Via: 0 Fed Ex F1 ups l Hand El Other Bill of Lading#Internal Container Temp.: Z-I Deg. C Custody Sealed?YO N)!Custody Seal Intact?Y50 NO 1) Relinquished By Date/Time

2) Received By Date/Time 3) Relinquished By Date/Time
4) Received By Date/Time Connecticut Yankee J1*3741 /Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:-

6&iWb'Qo M 2\ )SDG#: Work Order Number: Shipping C*otainer ID: .--fr/, Chain of Custody # 3 OOo -00 ( Pq I. Custody Seals oan shipping container intact?. Yes [-,1' o 4 1 2. Custody Seals dated and signed? Yesj[1 No q[-3. Chain-of-Custody record present? Yes [-'o [ ].4. Cooler temperature

5. Vermiculite/packing materials is: Wet ] Dry* I]/6.' Number of samples in shipping container:

6 7. Sample holding times exceeded?

Yes [ ] No.8. Samples have:-hazard labels*~custody seals 7' appropriate sample labels 9. Samples arei.in good condition leaking-have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ I No [,]" 11...Description of anomalies, (include sample numbers): eampleoCustdiantLaboratry:

-5..w_________

  • Telephoned to.Page 33 Of 105 9 SAMPLE RECEIPT & REVIEW FORM I'm we only I[lent: IakeSDG/ARCOC/Wffk Order: lbV V, Date Received:

'24AA P M(Al Revie (cmem RNn-~admuftitemun are remive prior to igalug): Rec:ved By: Sample Receipt Criteria CommnentQuaihiers (Required for Non.Conforming Items)Shipping containers received intact /Apllble:

nab M*cn dnmapl centimme lekhg c er (describe)

Samples requiring cold bdC Caalm 0 ice bass blue ice dry ice %1 dmerdesaic 2preservation within (4 +/- 2CQ?/Record preservation method.Chain of custody documents[ jmcchr~Sinhded with shipmentý?

_______________

4Samplee containers intact and Cocke A~psicahl neab bteake darnsied conaliner leakftingceer ahi (describe) sealed?p~Samples rd? uirin chemical / M'L coimeni aiffced and observed pH: reservation at poer pH?VOA vials free of beadspa sf WSA'd comnainers aftlcled (defined as < 6mm bubble)?Are Encore containers present?7 (If yes. Immediately deliver to VOA laboratory) 8 Samples received within holding /n n time?9 mle ID's on COC match ID's /ID'$ sow cinmers on bottles?10 Date & time on COC match date ID's eafftco:& time on bottles?Numbcr of containers received /ID's aff'e: match number indicated on COC?COC form is properly signed in mreliquished/received sections?Air Bill ,Tracking

  1. -s, &'""IditionalComens I Suvsiptedi ard Informaton I it a II It5RAD Reccip I__________

re f > lfX2 ame badkground is observed on sample idegiJ~d as nn t reguslated/nonradiatfmive", conwat the Padition Safety group hbr fiamhe in .... .... .. .I .I A 3naOiogkiai UlassitjCation-fP~4 m m .ul I-B*It a a e regulated?

/CCMatwerrial?, if Yes, contact WasteIV M Manager or ESH Manager. __ýounft Observed*:

Qa h,-1 ;Fý -p,., -k5o A Class Shipped: nw ~or IMA) review of Hazard ciassiflaneinn*

.............

i. 4"- 4LL6 Date: Page 34 of 105 SAMLERECEIPT

& REVIEW FORM'P4lrORItS' PM Use only Ci.ent: ' & SDGIARCOC/Work Order: 37 /Date Received:

'57wI PM(A) Review (elisure non-confornling items ame resolve Prior to signing): Received By: C 1A rfn h, ____________________

Sample Receipt Criteria ~CommentslQuallflers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe)

_and sealed? , Samples requiring cold Circle Coolant # ice bags blue ice dry ice otber describe)2 preservation within (4 +/- 2 C)?Record preservation method. f,1" Chain of custody documents ,included with shipment?

Cirle _______sabbrke

_d maed ___________cotane

_ohe ______Sample containers intact and Circle Applicable:

seals broken damaged conainer leaking conainer othe (describe) sealed?Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH?VOA vials free of headspace Sample ID's and contauiner affected: (defined as < 6mm bubble)? ,_,_, Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding Id's an tests affected: time? Vol, 9 Sample ID's on COC match ID's Sanpt ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received a ID' affected: match number indicated on COC?COC form is properly signed in A04-"-

AW q ,4/, relinquished/reccived sections?C--45r- 2~ -W C O -Late'14 Air Bill Tracking #s, & 1 V ,+ 4e 'j* ,-5 Additional Comments o' " T RSO RAD Receipt #__H d .9 *if > x2 area background is observed on samples identified as "non-Suspected Hazard Information al regulated/non-radioactive*.

contact the Radiation Safety group for further m investigation.

A Radiological Classification. -V Maximum Counts Observed*:'

B fPCB Regulated?

Comments: IShipped as DOT Hazardous

.C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. U PM (or PMA) review of Hazard classiticauion:

Initials Date: I I Page 35 of 105 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

_j(0ic to SDG#: Work Order Number: Shipping Cdntainer ID: 1!56i 1 ' I 73 Chain of Custody'#

C"r 1. Custody Seals. oii shipping container intact?...

Yes j o 2. Custody Seals dated and signed? Yes f,,lo [ ]3. Chaia-of-Custody record present? 'Yes LA41o [ ]4. Cooler temperature

5. Vermiculite/packing materials is: Wet VDry [',]6." Number of samples in shipping container: .a h A-7. Sample holding times exceeded?

Yes.[ NoD.8. Samples have: t .tape -hazard labels custody seals -appropriate sample labels 9. Samples are::u"in good condition leaking.broken -have air bubbles 10. Were any anomalies.identified in sample receipt? Yes [ ] No [.-<11. Description of anomalies (include sample numbers):

I P Sample Custodian/Laboratory: (c4 e" Date:___________________

Telephoned to: ^On By_Page 36 of105 .

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major 164-4ol I Chain of Custody Form CD Connecticut Yankee Atomic Power Company No. 2006-00380 362 Injun Hollow Road, East Hampton, CT 06424 o 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested .Lab'.Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories

<2040 Savage Road. Charleston SC. 29407 C0 <843 556 8171. Attn. Cheryl Jones V) Cn Priority:

Z 30 D. El 14 D. El 7 D. Container Sample Size-Media Type &Type ." Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID9106-0009-016F 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352

~ 9106-0009-01 6FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 08:05 SE C BP -X Transferred from COC 2006-00351 0 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 m 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 OiV 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 9106-0009-014F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 9106-0009-015F

~ ~~~ ~ 5/'50 093IEC B rnfre rmCC20-05 NOTES: PO #: 002332 MSR #: 06-O/g' SSWP# NA SLTP QA El Radwaste QA El Non QA 1) Relinquised By Date/Time

2) Rec v d y Date/Time 3) Relinquished By Date/Time
4) Re eive By Date/Time Samples Shipped Via:[ Fed Ex El uis El Hand El Other Bill of Lading #¢qz/.VS 2A-Internal Container Temp.: ___ Deg. C Custody Sealed?YO NO Custody Seal Intact?Y 17 N !"

Health Physics Procedure/ 1,4 gva -/.GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 1l I I I I l CD 0(C U Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C V Priority:

E 30 D. [] 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-00IF 5/11/06 13:22 SE C BP X x X Transferred from COC 2006-003479106-0009-002F 5/11/06 13:46 SE C BP x x Transferred from COC 2006-00347 A 9106-0009-003F 5/11/06 14:06 SE C BP x x Transferred from COC 2006-00347 b 9106-0009-004F 5/11/06 14:30 SE C BP X X -Transferred from COC 2006-00347

$ 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347

i/"9106-0009-007F 5/12/06 07:44 "SE C BP X X Transferred from COC 2006-00348 9106-0009-008F 5/12/06 08:16 SE C BP X X Transferrd from COC 2006-00348 (4 .9106-0009-009F 5/12/06 08:35 SE C BP x X Transferred from COC 2006-00348 4 9106-0009-OIOF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 at 01 0(NOTES: PO #: 002332 MSR #: 06-SSWP# NA Z LTP QA El Radwaste QA E] Non QA 1) Relinquished By.Jf17k.1f 9...kr Date/Time 1 2 R c
  • ZE&Date/Time e"/Al/0(.

C?06 Samples Shipped Via:[ Fed Ex E] Hand Ml Other Bill of Lading #fent! ly/y- z2yi-Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YO ND-F --- I 3) Relinquished By Date/Time 4) Received t By /bate/Time Connecticut Yankee Statement of Work for Analytical Lab Services 7wq CY-lSC-soW-o0 I Figure 1. Sample Check-in List Date/Time Received-

-B 0 (0 SDG#: ms C5"0 -0 e I Work Order Number:* ',I -MIS 2.91;Shipping Cdhtainer ID: "ti"-1. Custody Seals. oni shipping container intact?2. Custody Seals dated and signed?3. Chain-of-Custody record pres ent?4. Cooler teemperature e0 5. Vermiculite/packing materials is: 6. Number of samples in shipping container:

7. Sample holding times exceeded?.G.IV q t o%(5(Chain of Custody # d.,_o6 2__ !8_ 1_-Yes XJNo []Yes [ No ,ND Yes 04 No L I Wet H DryN [Yes D( No( I 8. Samples have:->..... .__hazard labels~ stody seals _appropriate sample labels 9. Samples are:* i good condition -leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes[]No 11. * .Description of anomalies (include sample numbers): Sample Custodian/Laboratory:..

Date. 4 .. .Telephoned to: On By, Page 39 of 105 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 c Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy .860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones X Priority:

Z 30 D. [] 14 D. El 7 D. Container Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0010-001F 5/04/06 10:49 SE C BP X X Transferred from COC 2006-00321 010 9106-0010-002F 5/04/06 11:12 SE C BP X X Transferred from COC 2006-00321 0(1 9106-0010-004F 5/04/06 12:48 SE C BP X X Transferred from COC 2006-00321

___9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321

-9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 0 6 9106-0010-010F 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 o 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321

-0 9106-0010-013F 5/04/06 15:06 SE C BP X Transferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 07*07 SSWP#NA SLTP QA El Radwaste QA 0l Non QA 1) RelinquisheABy Date/Ti e 2) Received y Date/Time 3) Relinquished By DatefIime

4) Received By Date/Time Samples Shipped Via:[ Fed Ex EUPS ElHand El Other Bill of Lading I#~904- 3 ýf Internal Container Temp.: /7Deg. C CustodySealed?

Y9" NO Custody Seal Intact?Y 9 ND Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SoW-O01 Figure 1. Sample Check-in List D a t e / T i m e R e c e iv e d : qMf /7 / .0 6 , SDG #: n U le .Q C# -7t9"70 Work Order Number: Shipping Ccfitainer ID : rt5 Chain of Custody # -6 3 9 1. Custody Seals ori shipping container intact? -Yes [(] No [ J 2. Custody Seals dated and signed? Yes [V No [ I. -3. Chain-of-Custody record present? Yes [D No [ ]4. Cooler temperature (7 C 5. Vermiculite/packing materials is: Wet pq Dry I' J 6: ! *Number of samples in shipping container:

_;7. Sample holding times exceeded?

Yes [ ] No Pq 8. Samples have:-tape -h__hazard labels.. _-c u s tod y s e a ls .ap p m p r ia te s a m p le la b e ls 9. Samples are:'99in good condition

-.jeaking-broken -have air bubbles 10. W ere any anom alies identified in sample receipt? Yes [ ] No *KQ 1... ~Description of anomalies (include sample numbers): Sarnple, Custodian/Lab~oratory:

4-0~d~ DaeG-~-O Telephoned to:. On By Page 41 of 105ýt I'll Itt A ; 'sSAMPLE RECEIPT & REVIEW FORM 0;P1ro0R&" PM uise only Client: a , -X SDG/ARCOC/Work Order: Date Received:

S- I? -0,b PM(A) Review ( E 0 g item are resolved prior to signing): Received By: 7-A4 Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)Z- -I Shipping containers received intact Circle Applicable:

seals broken damaged conainer leaking container other (describe) and sealed? I Samples requiring cold Circlc Coolant # ice bags blue ice dry ice oiie) other describe)2 preservation within (4 +/- 2 C)?Record preservation method. ,_......Chain of custody documents included with shipment?4 Sample containers intact and ircle Applicabe seats broken damaged conainer Inking container other (describe) sealed?Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH? ,_6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding Id's and tests affected: time?Sample ID's on COC match ID's Sarmle tD's and containers affected: on bottles?10 Date & time on COC match date Sample ID's affected:& time on bottles? ......Number of containers received Sampte ID's affected: match number indicated on COC? V 12 COC form is properly signed in relinquished/received sections?Air Bill ,Tracking

  1. 's, & ..,,-Additional Comments 31? 1 v -6 RSO RAD Receipt #Suspected~

~~ gaar Infrnmio *> x2 area background is observed on samples identified as "non-Suspected Haar Inomtinb regulated/non-radioactive".

contact the Radiation Safety group for further A IRadiological Classification?

Maximum Counts Observed*:

05^ 4 6 B PCB Regulat-e-d? " Conmmnts: 'Shipped as D0T Hazardous C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

Initials 6 -Date: /_ ,-4 J-0 Z Page 42 of 105 List of current GEL Certifications as of 15 August 2006 State Certification Alaska UST-062 1 Arizona .AZ0668 Arkansas 88-0651 CLIA 42D0904046

-California 01151ICA Colorado -GenEngLabs-PH-0169.Dept. of Navy NFESC413 EPA ...WG-15J Florida/NELAP E8756 Georgia E87156 (FLJNELAP)

Idaho N/A Illinois 200029 Indiana ...C-SC-0 .Kansas E-10332 Kentucky 90129 Maryland 270 Massachusetts M-SCO 12 Michigan 9903 Nevada SCI-2 New Jersey SC002 New York 11501 North Carolina 233 North Carolina Drinking W 45709 NorthDakota R-158 Oklahoma 9904 Pennsylvania 68-485 , South Carolina 10120001/10585001/10120002 Tennessee

_ 0293 4-Texas Tk-TX213-2006A U.S. Dept. of Agriculture S-52597-USArmy Corps of Engineer N/A -Utah 8037697376 GEL Vermont N/A Virginia 00151 Washington C223 Page 43 of 105 RADIOLOGICAL ANALYSIS Page 44 of 105 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555696 554650 554649 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404011 168404012 168404013 168404014 168404015 1201153129 1201153130 1201153131 1201153132 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Page 45 of 105 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Page 46 of 105 Product: Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 557837 554650 554649 Sample ID 168404009 168404010 1201158316 1201158317 1201158318 1201158319 Client ID 9106-0006-005F 9106-0008-006F Method Blank (MB)168404009(9106-0006-005F)

Sample Duplicate (DUP)168404009(9106-0006-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105 All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555697 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 48 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153133 1201153134 1201153135 1201153136 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 49 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-i l-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555698 554650 554649 Page 50 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153137 1201153138 1201153139 1201153140 Client ID 9106-0002-007F 9106-0002-011F 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 51 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 556350 554650 554649 Page 52 of 105 Sample ID 168404003 168404004 168404012 168404013 168404014 168404015 1201154644 1201154645 1201154646 1201154647 Client ID 9106-0003-004F 9106-0003-015F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105 Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F), 1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150561 1201150562 1201150563 1201150564 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OOIF 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.-Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 55 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555722 554650 554649 Page 56 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153222 1201153223 1201153224 1201153225 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 57 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Renanalysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555723 554650 554649 Page 58 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 1201153226 1201153227 1201153228 1201153229 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Page 59 of 105 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150569 1201150570 1201150571 1201150572 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 554582 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)Page 60 of 105 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Page 61 of 105 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150573 1201150574 1201150575 1201150576 EPA EERF C-01 Modified 554583 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Page 62 of 105 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.Page 63 of 105 The following data validator verified the information presented in this case narrative:

Reviewer/Date: S< z]4 6 Page 64 of 105 SAMPLE DATA

SUMMARY

Page 65 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by Page 66 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: 9106-0002-007F Project: YANK01204 Sample ID: 168404001 Client ID: YANKOOI Matrix: SE Vol. Recv.: Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector:

Client Moisture:

20.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0762 Curium-242 U 0.00 Curium-243/244 U -0.00853 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.199 Plutonium-239/240 U 0.0341 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.0 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.17 Liquid Scint C14, SolidAll,FSS Carbon- 14 U 0.0813 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 9.90 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.139+/-0.102+/-0.0995+/-0.0717+/-0.228+/-0.129+/-6.64+/-6.67+/-0.0797+/-48.1+/-6.39+/-0.213 0.00 0.00 0.0405 0.181 0.120 5.08 5.28 0.0634 32.0 5.18 0.173+/-0.102+/-0.0995+/-0.0717+/-0.229+/-0.129+/-6.72+/-6.67+/-0.0797+/-48.1+/-6.40+/-0.213 0.0956 0.138 0.177 0.444 0.323 10.7 11.4 0.132 65.9 10.6 0.360 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1336 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1220 555698 3 DFA I ATH2 MXPI MXPI EGD1 08/09/06 1128 554582 08/09/06 0324 554583 08/12/06 1633 555722 08/11/06 0738 555723 08/11/06 2027 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified Page 67 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0002-007F 168404001 Project: YANKO 1204 Client ID: YANK00I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu24 1, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%80 100 98 75 76 74 Acceptable Limits (15%-125%)

(15%6-125%)

(25%-I125%)

(15%-125%)

(25%-/125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 68 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0002-01 IF 168404002 SE 19-MAY-06 02-JUN-06 Client 17.4%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.120 Curium-242 U -0.0146 Curium-243/244 U -0.0103 Alphaspec Pu, Solid-ALL FSS Plutoniurn-238 U 0.0121 Plutonium-239/240 U 0.0254 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.521 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.023 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.154+/-0.122+/-0.0861+/-0.125+/-0.0675+/-7.02+/-7.03+/-0.0828+/-47.7+/-5.81+/-0.203 0.0683 0.0692 0.0487 0.127 0.0381 5.56 5.94 0.0685 31.9 4.68 0.164+1-0.155+/-0.123+/-0.0862+/-0.125+/-0.0675+/-7.05+/-7.03+/-0.0828+/-47.7+/-5.81+/-0.203 0.251 0.303 0.213 0.344 0.167 11.7 12.8 0.143 65.7 9.60 0.341 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1336 555696 1 BXL1 08/11/06 1633 555697 2 BXLI 08/16/06 1237 555698 3 DFAI ATH2 MXP1 MXP I EGDI 08/09/06 1143 554582 08/09/06 0426 554583 08/12/06 1649 555722 08/11/06 0825 555723 08/11/06 2043 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-1 I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 69 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: 9106-0002-011F 168404002 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu24 1, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%

Acceptable Limits 76 (15%-125%)

100 (15%-125%)

88 (25°-125%)

72 (15%-/125%)

76 (25%-125%)

79 (15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 70 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis C et if c t o .. .. .... .. .... ..Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0003-004F 168404003 SE 25-APR-06 05-MAY-06 Client 23.5%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U Curium-243/244 U Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gas Flow Proportional Counting-0.027 0.112 0.0217 0.061 0.0551+/-0.117+/-0.315+/-0.206 0.153 0.245 0.205+/-0.117+1-0.315+/-0.206+/-0.189 0.176 +/-0.189+/-0.103 0.0584 +/-0.103 0.488 0.781 0.594 0.449 0.215 9.25 0.036 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 8.31 +/-5.73 4.40 +/-5.78 GFPC, Sr90, solid ALL FSS Strontium-90 U -0.00343 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0937 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 7.68 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643+/-0.0203 0.0172 +/-0.0203+/-8.25 6.87 +/-8.25+/-0.0813 0.0642 +/-0.0813+/-51.2 34.2 +/-51.2+/-7.12 6.58 +/-7.13+/-0.198 0.169 +/-0.198 BXLI 08/13/06 0819 555696 1 BXL1 08/11/06 1633 555697 2 BXLI 08/16/06 1253 555698 3 BXFI 08/14/06 0834 556350 4 DFAI 08/09/06 1159 554582 5 ATH2 08/09/06 0529 554583 6 MXPI 08/12/06 1706 555722 7 MXP1 08/11/06 0912 555723 8 EGD1 08/11/06 2059 554580 9 14.8 pCi/g 0.134 70.4 pCi/g pCi/g 13.6 pCi/g 0.351 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified Page 71 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-004F 168404003 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 4 5 6 7 8 9 DOE EML HASL-300, Pu-11-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%

Acceptable Limits 42 (15%-125%)

92 (15%-125%)

113 (25%-/125%)

59 (25%- 125%)71 (15%-125%)

83 (25%-125%)

76 (15%-1250/.)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-004F 168404003 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 73 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0003-015F 168404004 SE 25-APR-06 05-MAY-06 Client 22.5%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 Curium-242 U 0.113 Curium-243/244 U 0.180 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0196 Plutonium-239/240 U 0.0326 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00477 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+1-0.155+/-0.181+/-0.239+/-0.121+/-0.0639+/-6.19 0.139 +/-0.155 0.0733 +/-0.182 0.181 +/-0.240 0.118 +/-0.121 0.00 +/-0.064 4.86 +/-6.22+/-0.0216 0.0179 +/-0.0216 0.387 0.321 0.472 0.324 0.0884 10.2 0.0375 12.6 0.146 59.2 21.6 0.353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1309 555698 3 BXF1 08/14/06 0834 556350 4+/-7.06+/-0.0912+/-42.7+/-10.1+/-0.213 5.85 +/-7.06 0.0699 +/-0.0913 28.7 +/-42.7 10.3 +/-10.1 0.170 +/-0.213 DFAI ATH2 MXPI MXPI EGDI 08/09/06 1215 554582 08/09/06 0632 554583 08/12/06 1722 555722 08/11/06 1001 555723 08/11/06 2115 554580 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified Page 74 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 4 5 6 7 8 9 DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%78 94 101 58 75 62 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-I125%)

(25%- 125%)(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 76 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.036 Curium-242 U -0.0169 Curium-243/244 U -0.0129 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0217 Plutonium-239/240 U -0.0708 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 9.52 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.854 Liquid Scint C14, SolidAllFSS Carbon- 14 0.347 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -1.57 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 6.39 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0198 9106-0004-005F 168404005 SE 03-MAY-06 12-MAY-06 Client I C AO0 Project: Client ID: Vol. Recv.: YANK01204 YANK001 1 J.L' U0 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.123+/-0.033+/-0.227 0.157 +/-0.123 0.080 +/-0.0331 0.247 +/-0.227 0.437 0.350 0.619 0.444 0.337 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.163 0.181 +/-0.163+/-0.0791 0.128 +/-0.0795+/-6.00 4.57 +/-6.07+/-5.88 4.87 +/-5.88+/-0.097 0.0674 +/-0.0972+/-46.0 30.7 +/-46.0+/-7.62 7.40 +/-7.62+/-0.187 0.156 +/-0.187 9.61 pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1326 555698 3 DFAI 08/09/06 1231 554582 4 ATH2 08/09/06 0734 554583 5 MXPI 08/12/06 1738 555722 6 MXPI 08/11/06 1017 555723 7 EGD1 08/11/062131 554580 8 10.5 0.141 63.2 15.5 0.324 pCi/g pCi/g pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-1 I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 77 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0004-005F 168404005 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-1, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%

Acceptable Limits 65 (15%-/125%)

95 (150/.-125%)

105 (25%- 125%)78 (15°/-125%)

80 (25%-125%)

80 ( 15°/o- 125%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 78 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-015F 168404006 SE 03-MAY-06 12-MAY-06 Client 26.5%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U -Curium-243/244 U -Alphaspec Pu, Solid-ALL FSS Plutonium-238 U Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis 0.0823 0.0154 0.0994 0.0466-0.142+/-0.203+/-0.0301+/-0.251 0.178 0.0729 0.300+/-0.203+/-0.0302+/-0.251+/-0.213 0.210 +/-0.213+/-0.108 0.191 +/-0.109 6.64 +/-6.53 5.16 +/-6.57 0.469 0.319 0.713 0.521 0.483 10.8 14.2 0.149 64.4 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U 0.(Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.(BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1342 555698 3 DFAI 08/09/06 1247 554582 4 ATH2 08/09/06 0837 554583 5 MXPI 08/12/06 1754 555722 6 MXPI 08/11/06 1033 555723 7 EGD1 08/11/06 2147 554580 8-2.9 +/-7.59 6.60 +/-7.59 0352 +/-0.0868 0.0713 +/-0.0868 1.88 +/-46.8 31.3 +/-46.8 3.88 +/-7.46 7.40 +/-7.46 0894 +/-0.198 0.163 +/-0.198 15.5 pCi/g 0.338 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 79 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0004-015F 168404006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 8 DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 72 72 94 73 80 78 (15%o-125%)

(15°/-125%)

(25%-125%)

(15%-125%)

(25%-I125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 80 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-01 OF 168404007 SE 02-MAY-06 09-MAY-06 Client 56.2%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -(Curium-242 U -0.Curium-243/244 U -0.AIphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.Plutonium-239/240 U 0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.128 0115 0333+/-0.0939+/-0.128+/-0.122 0.142 0.147 0.149+/-0.0942+/-0.128+/-0.122 0.385 0.450 0.401 0.403 0.322 pCi/g pCi/g pCi/g pCi/g pCi/g 0548 +/-0.169 0.158 +/-0.170 0195 +/-0.121 0.117 +/-0.121 10.4 +/-6.89 5.27 +/-6.97 0.00 +/-6.86 5.76 +/-6.86 11.1 pCi/g 12.4 pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1358 555698 3 DFAI 08/09/06 1303 554582 4 ATH2 08/09/06 1017 554583 5 MXPI 08/12/06 1811 555722 6 MXPI 08/11/06 1049 555723 7 EGDI 08/11/06 2203 554580 8 Liquid Scint C14, SolidAll,FSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.0636+/-0.0801 0.0644 +/-0.0801 36.1 +/-44.1 28.7 +/-44.1 7.26 +/-10.2 10.0 +/-10.2 0.135 59.0 20.9 0.351 pCi/g pCi/g pCi/g pCi/g Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.05 +/-0.199 0.169 +/-0.199 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300.

Am-05-RC Modified 2 3 4 5 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-1 I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 81 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0005-010F 168404007 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%

Acceptable Limits 85 (15%/o-125%)

91 (15%-125%)

92 (25%-125%)

81 (15%-125%)

64 (25%-/125%)

77 (15%-1125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 82 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-014F 168404008 SE 02-MAY-06 09-MAY-06 Client 32.3%Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00591 Curium-242 U -0.04 Curium-243/244 U 0.0634 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0694 Plutonium-239/240 U -0.0287 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0892 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.134+/-0.219+/-0.0554+/-0.261 0.231 +/-0.219 0.134 +/-0.0557 0.249 +/-0.261 0.608 0.494 0.646 0.434 0.369 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.106 0.160 +/-0.106+/-0.098 0.127 +/-0.0981+/-8.01 6.48 +/-8.02+/-6.38 4.90 +/-6.38+/-0.0827 0.0655 +/-0.0827+/-46.3 30.6 +/-46.3+/-7.91 7.77 +/-7.91+/-0.192 0.167 +/-0.192 13.6 pCi/g 10.6 pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1415 555698 3 DFAI 08/09/06 1319 554582 4 ATH2 08/09/06 1424 554583 5 MXPI 08/12/06 1827 555722 6 MXPI 08/11/06 1106 555723 7 EGDI 08/11/06 2218 554580 8 0.137 62.9 16.2 0.346 pCi/g pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu- I -RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 83 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0005-014F 168404008 Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%

Acceptable Limits 50 (15%-125%)

61 (15o-125%)

74 (25°/-125%)

76 (15%-125%)

76 (25%-125%)

75 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a dilutedaliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 84 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005F 168404009 SE 28-APR-06 12-MAY-06 Client 16.5%LC TPU Parameter Qualifier R Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.Plutonium-239/240 U 0.0 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -Liquid Scint C14, SolidAll,FSS Carbon-14 (Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0 esult Uncertainty MDA Units DF Analyst Date Time Batch Mtd 0851 0253 0479 0183 0122 4.43-2.02 0.142 12.6 7.70 0659+/-0.136+/-0.0495+/-0.0542+/-0.113+/-0.0662+/-5.83+/-6.67+/-0.0798+/-47.6+/-9.56+/-0.185 0.106 0.120 0.131 0.110 0.0694 4.67 5.76 0.061 31.7 9.31 0.156+/-0.136+/-0.0496+/-0.0545+/-0.113+/-0.0662+/-5.85+/-6.67+/-0.0799+/-47.6+/-9.56+/-0.185 0.390 0.525 0.443 0.303 0.221 9.82 12.4 0.127 65.3 19.5 0.323 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/16/060949 557837 1 BXLI 08/11/06 1633 555697 3 BXLI 08/16/06 1431 555698 4 DFAI ATH2 MXPI MXPI EGD1 08/09/06 1335 554582 08/09/06 1719 554583 08/12/06 1843 555722 08/11/06 1122 555723 08/11/06 2234 554580 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-I I-RC Modified 5 EPA 906.0 Modified Page 85 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: 9106-0006-005F 168404009 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANKOOI Vol. Recv.: Units DF Analyst Date Time Batch Mtd Parameter 6 7 8 9 Qualifier Result Uncertainty EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified LC TPU MDA Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%76 93 105 72 64 81 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-/125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 86 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0008-006F 168404010 SE 05-MAY-06 26-MAY-06 Client 34.8%Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0 Curium-242 U 0 Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.1 Plutonium-239/240 U 0.01 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U 0 Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.129.103 0161+/-0.195+/-0.202+/-0.0316 0.0758 0.00 0.0766+/-0.196+/-0.203+/-0.0317 0276 +/-0.0711 0.0967 +/-0.0712 0359 +/-0.113 0.118 +/-0.113 14.9 +/-6.37 4.64 +/-6.51 0.00 +/-6.06 5.09 +/-6.06.107 +/-0.0846 0.0664 +/-0.0846 15.1 +/-41.4 27.5 +/-41.4'.258 +/-0.225 0.179 +/-0.225 0.332 0.280 0.335 0.275 0.317 9.75 10.7 0.139 56.6 0.373 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/16/06 0949 557837 1 BXLI 08/11/06 1633 555697 3 BXLI 08/16/06 1447 555698 4 DFAI 08/10/062150 554582 5 ATH2 08/09/06 1822 554583 6 MXPI 08/12/06 1900 555722 7 EGDI 08/11/06 2251 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 7 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified Page 87 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0008-006F 168404010 Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 77 94 103 72 71 (15%-(15%-(25%-(15%/-(15%/-125%)125%)125%)125%)125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H- Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 88 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: 9106-0008-008F Project: YANKO 1204 Sample ID: 168404011 Client ID: YANKOO Matrix: SE Vol. Recv.: Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector:

Client Moisture:

35.7%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, Solid A Il,FSS Carbon-14 U -0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.+/-0.192+/-0.142+/-0.202 0.152 +/-0.193 0.132 +/-0.142 0.240 +/-0.203+/-0.096 0.125 +/-0.096+/-0.114 0.137 +/-0.114 11.5 +/-6.72 5.08 +/-6.80 0.00 +/-5.92 4.97 +/-5.92 0238 +/-0.0745 0.0636 +/-0.0745-10.7 +/-40.9 27.5 +/-40.9 0956 +/-0.211 0.174 +/-0.211 0.426 0.446 0.603 0.328 0.353 10.7 10.7 0.133 56.8 0.361 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1504 555698 3 DFAI 08/09/06 1407 554582 4 ATH2 08/09/06 1924 554583 5 MXP1 08/12/06 1916 555722 6 EGDI 08/11/06 2307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified Page 89 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO 1204 Sample ID: 168404011 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%/o-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 96 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 90 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-002F 168404012 SE 11 -MAY-06 08-JUN-06 Client 33%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 Curium-242 U 0.0192 Curium-243/244 U 0.013 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 Plutonium-239/240 U 0.0186 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0151 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.046 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 12.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078+/-0.155+/-0.145+/-0.268 0.166 0.135 0.281+1-0.155+/-0.145+/-0.268+/-0.0493 0.0279 +/-0.0494+/-0.0492 0.0278 +/-0.0493+/-6.90 5.13 +/-7.01+/-0.0146 0.0114 +/-0.0146+/-8.36 6.70 +/-8.36+/-0.0755 0.0613 +/-0.0755+/-40.6 26.8 +/-40.6+/-0.203 0.168 +/-0.203 0.458 0.455 0.687 0.122 0.122 10.8 0.0242 14.5 0.128 55.2 0.348 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1632 555697 2 BXLI 08/16/06 1520 555698 3 BXF1 08/14/06 0834 556350 4 DFA1 08/09/06 1422 554582 5 ATH2 08/09/06 2027 554583 6 MXPI 08/12/06 1932 555722 7 EGD1 08/11/06 2323 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu- 11-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 91 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Project: YANK01204 Sample ID: 168404012 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Amr241, Cm, Solid ALL 61 (15/-,125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 94 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 92 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-017F 168404013 SE 15-MAY-06 08-JUN-06 Client 28.4%Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 Curium-242 U 0.0957 Curium-243/244 U -0.073 Alphaspec Pu, Solid ALL FSS Plutonium-238 U -0.00629 Plutonium-239/240 U 0.0262 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0205 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid HTD2,ALL FSS Tritium U 0.583 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.0271 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628+/-0.242+/-0.220+/-0.214+/-0.0529+/-0.0513 0.230 0.171 0.256+/-0.243+/-0.220+/-0.214 0.574 0.509 0.627 0.131 0.0709 pCi/g pCi/g pCi/g pCi/g pCi/g 0.0299 +/-0.0529 0.00 +/-0.0514+/-6.66 4.95 +/-6.77+/-0.0151 0.0116 +/-0.0151+/-7.98 6.65 +/-7.98+/-0.0759 0.0625 +/-0.0759+1-150 102 +1-150+/-0.200 0.165 +/-0.200 10.4 pCi/g 0.0246 pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1632 555697 2 BXLI 08/16/06 1536 555698 3 BXF1 08/14/06 0833 556350 4 DFA1 08/09/06 1438 554582 5 ATH2 08/09/06 2129 554583 6 MXPI 08/12/06 1949 555722 7 EGDI 08/11/06 2338 554580 8 14.4 pCi/g 0.131 pCi/g 210 pCi/g 0.343 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 93 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21,,2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANK01204 Sample ID: 168404013 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-1125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 96 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%- 125%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 94 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0010-00IF 168404014 SE 04-MAY-06 17-MAY-06 Client 27.3%Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00677 Curium-242 U 0.0854 Curium-243/244 U 0.0361 AIphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.173 Plutonium-239/240 U -0.0342 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.0128 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.548 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0555 Liquid Scint Fe55, Solid-ALL FSS lron-55 U -18.1 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.134+/-0.227+/-0.167+/-0.242 0.238 +/-0.227 0.00 +/-0.168 0.241 +/-0.242+/-0.181 0.143 +/-0.182+/-0.0865 0.0951 +/-0.0866+/-6.44 4.78 +/-6.54+/-0.0141 0.0125 +/-0.0141+/-7.50 6.25 +/-7.50+/-0.0809 0.0655 +/-0.0809+/-47.6 32.3 +/-47.6+/-0.205 0.167 +/-0.205 0.628 0.231 0.634 0.331 0.235 10.0 0.0262 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 2250 555697 2 BXLI 08/16/06 1553 555698 3 BXFI 08/14/06 0833 556350 4 DFA1 08/09/06 1454 554582 5 ATH2 08/09/06 2232 554583 6 MXPI 08/12/06 2005 555722 7 EGDI 08/11/06 2354 554580 8 13.5 pCi/g 0.137 66.6 0.347 pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300.

Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-1I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 95 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Project: YANK01204 Sample ID: 168404014 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-l, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25°-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25°%- 125%)Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 96 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0010-012F 168404015 SE 04-MAY-06 17-MAY-06 Client 28.1%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 Curium-242 U -0.0547 Curium-243/244 U -0.126 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 Plutonium-239/240 U 0.0867 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00771 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 Liquid Scint C14, Solid A /1, FSS Carbon-14 U 0.0162 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 23.3 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577+/-0.184+/-0.141+/-0.184 0.140 +/-0.184 0.192 +/-0.141 0.245 +/-0.185+/-0.126 0.122 +/-0.126+/-0.0869 0.0406 +/-0.0872+/-6.16 4.77 +/-6.21+/-0.0144 0.0124 +/-0.0144+/-6.17 5.11 +/-6.17+/-0.0763 0.0633 +/-0.0763+/-49.3 32.5 +/-49.3+/-0.206 0.171 +/-0.206 0.386 0.544 0.597 0.291 0.128 10.0 0.0263 11.0 0.132 67.0 0.354 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 2250 555697 2 BXLI 08/16/06 1609 555698 3 BXFI 08/14/06 0833 556350 4 DFAI 08/09/06 1510 554582 5 ATH2 08/09/06 2334 554583 6 MXPI 08/12/06 2021 555722 7 EGD1 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu- 11-RC Modified EPA 905.0 Modified Page 97 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0010-012F 168404015 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%81 91 99 68 74 75 Acceptable Limits (15%o-125%)

(150/-125%)

(25%-I125%)

(25%-/125%)

(15%-125%)(I5%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 98 of 105 I QUALITY CONTROL DATA Page 99 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: August 21, 2006 Page 1 of 6 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

168404 Parmname NOM Samnle Oual OC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 555696 QCI201153130 Americium-241 Curium-242 Curium-243/244 QC1201153132 Americium-241 168340011 DUP U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0:0756 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 LCS Curium-242 Curium-243/244 QC1201153129 Americium-241 MB 12.8 Uncert: TPU: Uncert: TPU: 15.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.0578+/-0.278+/-0.279 U -0.0405+/-0.0562+/-0.0565 U -0.0517+/-0.257+/-0.257 12.8+/- 1.84+/-2.70 U -0.0328+/-0.0454+/-0.0457 14.3+/-1.94+/-2.92 U 0.0471+/-0.157+/-0.157 U -0.0469+/-0.0459+/-0.0464 U -0.00385+/-0.210+/-0.210 pCi/g 204 pCi/g 200 pCi/g 98 pCi/g (0%- 100%) BXLI 08/11/06 14:34 (0%- 100%)(0%- 100%)100 (75%-125%)

Curium-242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 92 (75%-125%)

Curium-243/244 QCI201153131 Americium-241 168340011 MS Curium-242 13.3 Uncert: TPU: Uncert: TPU: 16.1 Uncert: TPU: U -0.000522+/-0.0385+/-0.0385 U 0.00+/-0.0756+/-0.0756 U -0.0177+/-0.0764+/-0.0765 U 12.0+/-1.38+/-2.08 0.0427+/-0.0837+/-0.0839 15.9+/-1.58+/-2.61 91 (75%-125%)

Curium-243/244 99 (75%-125%)

Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0%- 100%) BXLI 08/11/06 22:51 Page 100 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 2 of 6 Parmname NOM Sample Qual OC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 555697 Plutonium-239/240 QC1201153136 LCS Plutonium-238 Plutonium-239/2 4 0 QC1201153133 MB Plutonium-238 Plutonium-239/2 4 0 QC1201153135 168340011 MS Plutonium-238 Plutonium-239/240 Uncert: +/-0.0215 TPU: +/-0.0216 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 Uncert: TPU: 11.8 Uncert: TPU: Uncert: TPU: Uncert: TPU: u -0.0155 Uncert: +/-0.0215 TPU: +/-0.0216 12.3 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 U 7.28 Uncert: +/-6.30 TPU: +/-6.35 U+/-0.0465+/-0.0466-0.0489+/-0.124+/-0.124 pCi/g 2410 (0%- 100%)(75%-125%)

U 0.155+/-0.141+/-0.142 11.5+/-0.856+/-1.32 U 0.0552+/-0.186+/-0.186 U -0.0978+/-0.0892+/-0.0899 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 98 (75%-125%)

08/11/06 22:50 U 0.0539+/-0.112+/-0.112 10.3+/-0.796+/-1.19 (75%-125%)

08/11/06 22:51 84 (75%-125%)

Batch 555698 QC1201153138 168340011 DUP Plutonium-241 QC1201153140 LCS Plutonium-241 QC1201153137 MB Plutonium-241 QC1201153139 168340011 MS Plutonium-241 137 Uncert: TPU: Uncert: TPU: 138 U Uncert: TPU: U 10.1+/-6.39+/-6.46 145+/-12.5+/-19.9 U 8.57+/-6.93+/-6.98 pCi/g pCi/g pCi/g pCi/g (0% -100%) BXLI 08/16/06 16:41 106 (75%-125%)

08/16/06 17:14 08/16/06 16:25 08/16/06 16:58 7.28+/-6.30+/-6.35 142+/-12.4+/-19.7 103 (75%-125%)

Batch 557837 QC1201158317 168404009 DUP Americium-241 Curium-242 U -0.0851 Uncert: +/-0.136 TPU: +/-0.136 U -0.0253 U 0.167+/-0.220+/-0.221 U 0.241 pCi/g 616 pCi/g 247 (0%- 100%) BXLI 08/16/06 09:49 (0%- 100%)Page 101 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 3 of 6 Parmname Rad Alpha Spec Batch NOM Sample _Qual QC Units RPD%REC% Range Anist Date Time 557837 Curium-243/244 QC1201158319 Americium-241 Curium-242 Curium-243/244 QCI201158316 Americium-241 Uncert: +/-0.0495 TPU: +/-0.0496 U -0.0479 Uncert: +/-0.0542 TPU: +/-0.0545 LCS MB 24.5 Uncert: TPU: Uncert: TPU: 29.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.334+/-0.335 U 0.0761+/-0.149+/-0.149 25.4+/-2.47+/-4.16 U 0.0477+/-0.127+/-0.127 27.0+/-2.54+/-4.38 U 0.234+/-0.275+/-0.277 U 0.00+/-0.152+/-0.152 U -0.0551+/-0.0624+/-0.0628 pCi/g 879 Curium-242 Curium-243/244 QC1201158318 168404009 MS Americium-241 Curium-242 Curium-243/244 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 91 (75%-125%)

(0% -100%)104 (75%-125%)

Rad Gas Flow Batch 556350 26.4 U -0.0851 Uncert: +/-0.136 TPU: +/-0.136 U -0.0253 Uncert: +/-0.0495 TPU: +/-0.0496 32.4 U -0.0479 Uncert: +/-0.0542 TPU: +/-0.0545 U -0.00343 Uncert: +/-0.0203 TPU: +/-0.0203 1.56 Uncert: TPU: Uncert: TPU: U 29.1+/-2.97+/-5.01 0.126+/-0.247+/-0.248 31.7+/-3.12+/-5.39 110 (75%-125%)

98 (75%-125%)

QC1201154645 168404003 DUP Strontium-90 QC1201154647 LCS Strontium-90 QC1201154644 MB Strontium-90 U -0.00637+/-0.0152+/-0.0152 1.30+/-0.0563+/-0.0881 U 0.0176+/-0.018+/-0.018 pCi/g 0 (0% -100%) BXFI 08/14/06 08:33 pCi/g pCi/g 83 (75%-125%)

Page 102 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 4 of 6 REC% Range Anist Date Time Parmname NOM Sample Oual OC Units RPD%Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 Rad Liquid Scintillation Batch 554580 QC1201150562 168340012 DUP Technetium-99 QC1201150564 LCS Technetium-99 1.58 U Uncert: TPU:-0.00343+/-0.0203+/-0.0203 1.29+/-0.0535+/-0.0813 pCi/g 82 (75%-125%)

U 0.0338 Uncert: +/-0.192 TPU: +/-0.192 U 0.266+/-0.226+/-0.226 13.6+/-0.496+/-0.599 pCi/g 0 (0% -100%) EGDI QC1201150561 Technetium-99 MB 13.1 Uncert: TPU: Uncert: TPU: 13.0 U Uncert: TPU: U 0.0311+/-0.177+/-0.177 pCi/g pCi/g pCi/g 103 (75%-125%)

08/12/06 00:42 08/12/06 01:14 08/12/06 00:26 08/12/06 00:58 QCI201150563 168340012 MS Technetium-99 0.0338+/-0.192+/-0.192 12.0+/-0.523+/-0.602 92 (75%-125%)

Batch 554582 QC1201150570 168340011 DUP Tritium QC1201150572 LCS Tritium QC1201150569 MB Tritium QC1201150571 168340011 MS Tritium U 1.77 Uncert: +/-8.20 TPU: +/-8.20 U 1.62+/-7.47+/-7.47 pCi/g 0 (0% -100%) DFA I 68.3 Uncert: TPU: Uncert: TPU: 61.3 U Uncert: TPU: 76.2+/-14.0+/-14.1 U 0.586+/-8.01+/-8.01 pCilg pCi/g pCilg I11 (75%-125%)

08/09/06 15:42 08/09/06 16:14 08/09/06 15:26 08/09/06 15:58 1.77+/-8.20+/-8.20 Batch 554583 QC1201150574 168404003 DUP Carbon- 14 QC1201150576 LCS Carbon- 14 U 0.0937 Uncert: +/-0.0813 TPU: +/-0.0813 U 61.8+/-12.2+/-12.3 0.0422+/-0.075+/-0.0751 7.14+/-0.508+/-0.520 101 (75%-125%)

pCi/g 0 (0% -100%) ATH2 08/10/06 01:39 08/10/06 03:00 7.27 Uncert: TPU: pCi/g 98 (75%-125%)

QC1201150573 MB Page 103 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 5 of 6 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Liquid Scintillation Batch 554583 Carbon- 14 QC1201150575 168404003 MS Carbon-14 Uncert: TPU: U -0.0315+/-0.0776+/-0.0776 pCi/g pCi/g 15.1 U Uncert: TPU: 0.0937+/-0.0813+/-0.0813 13.8+/-1.00+/-1.03 92 (75%-125%)

08/10/06 02:43 Batch 555722 QC1201153223 168340012 DUP Iron-55 U -26.5 Uncert: +/-65.1 TPU: +/-65.1 U 5.83+/-36.9+/-36.9 pCi/g 0 (0%- 100%) vIXPI 08/12/06 20:54 QC1201153225 LCS Iron-55 QC1201153222 MB Iron-55 641 Uncert: TPU: Uncert: TPU: 717 U Uncert: TPU: 660+/-56.2+/-67.2 U 18.2+/-39.6+/-39.6 pCi/g pCi/g pCi/g 103 (75%-125%)

08/12/06 21:27 08/12/06 20:38 08/12/06 21:11 QC1201153224 168340012 MS Iron-55-26.5+/-65.1+/-65.1 688+/-60.2+/-71.6 96 (75%-125%)

Batch 555723 QC1201153227 168340012 DUP Nickel-63 QC1201153229 LCS Nickel-63 QC1201153226 MB Nickel-63 QC1201153228 168340012 MS Nickel-63 U 3.79 Uncert: +/-5.39 TPU: +/-5.40 U 6.68+/-7.43+/-7.43 pCi/g 0 (0%- 100%) vIXPI 512 Uncert: TPU: Uncert: TPU: 479+/-22.4+/-27.1 U 15.7+/-9.92+/-9.93 pCi/g pCi/g pCi/g 94 (75%-125%)

08/11/06 11:55 08/I 1/06 12:27 08/11/06 11:38 08/11/06 12:11 530 U Uncert: TPU: 3.79+/-5.39+/-5.40 511+/.23.5+/-28.7 96 (75%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported Result is greater than value reported Page 104 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 6 of 6 QC Units RPD% REC% Range Anist Date Time Parmname NOM Sample Qual A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U UI X Y A h Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.Page 105 of 105 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area Survey 0002 Survey Discharge Canal 90 Unit #: Unit Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0002-014 Sample

Description:

Comparison of split samples collected from sample measurement location #014 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0002-014F the comparison sample was 9106-0002-014FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 0.OOE+00 2.22E-02 0 NONE -1.13E-02 1.24E-02 N/A N/A Co-60 1.46E-03 1.07E-02 0 NONE- -8.41E-03 1.25E-02 -5.76 N/A Sr-90 -2.35E-03 8.OOE-03 0 NONE- -7.OOE-03 7.25E-03 2.98 N/A K-40 1.04E+01 5.15E-01 20 0.75 1.33 1.09E+01 5.40E-01 1.05 Y Comments/Corrective Actions: In consideration of Cs-137, Co-60 & Sr-90 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. Since none of the radionuclides of concern were in a comparable range, K-40 was used to make the comparison and was found to be present at an acceptable level of agreement, therefore, no further action is warranted.

Table is provided to show acceptance criteria used to assess split samples.Resolution Agreement Range 4 8 16 51 7 15 50 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 200> 200 Performed By: WPIR- Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 0002 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-0021 SML #: 9106-0002-018 Sample

Description:

Comparison of split samples collected from sample measurement location #18 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0002-018F, the comparison sample was 9106-0002-018FS.

STANDARD COMPARI SON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 8.09E-02 1.54E-02 5 0.5 -2 9.55E-02 2.89E-02 1.18 Y Co-60 1.45E-01 2.09E-02 7 0.5 -2 3.25E-01 3.19E-02 2.24 N Sr-90 7.58E-03 5.60E-03 1 0.75 -1.33 -2.42E-03 6.15E-03 -0.32 N/A K-40 1.04E+01 5.15E-01 20 0.75 1.33 1.09E+01 5.40E-01 1.05 Y i I I Comments/Corrective Actions: Since Co-60 has a likelyhood to be present in the sample matrix in particulate form, one would not neccassarily expect it to be homogenuously mixed from processing of the sample-split aliqot. In consideration of Sr-90 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. Since both Cs-137 and K-40 were also found to be present at an acceptable level of agreement, no further action is warranted.

Table is provided to show acceptance criteria used to assess split samples.Resolution Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By: 7~4~Date 31 WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2c Preliminary Data Forms (1 Page)

Health Physics Procedure GPP-GGGR-R512 1 -001 Attachment B, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form -Samples for the Sign Test Survey Unit: 9106- 0002 Survey Unit Name: Discharge Canal Classification:

Survey Media: Type of Survey: Type of Measurement:

Number of Measurements:

Operational DCGL: 2 Soil Final Status Survey Radionuclide Specific 15 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Sr-90 Minimum Value: 0.OOE+00 1.46E-03 -1.3 1E-02 Maximum Value: 3.81E-01 6.39E-01 2.14E-02 Mean: 1.36E-01 2.07E-01 4.24E-03 Median: 1.23E-01 1.45E-01 6.81 E-03 Standard Deviation:

9.83E-02 1.83E-01 9.52E-03 RADIONUCLIDE CONCENTRATION (pCi/g)NUMBER 9106-0002-002F 9106-0002-004F 9106-0002-005F 9106-0002-007F 9106-0002-008F 9106-0002-009F 9106-0002-01 OF 9106-0002-01 IF 9106-0002-012F 9106-0002-013F 9106-0002-014F 9106-0002-015F 9106-0002-017F 9106-0002-018F 9106-0002-019F Performed By: Independent Review: Cs-137 2.64E-02 1.23E-01 1.98E-01 3.81 E-01 1.63E-01 1.84E-01 6.61 E-02 2.47E-01 1.75E-01 2.43E-02 O.OOE+00 1.16E-01 9.30E-02 8.09E-02 1.69E-01 Co-60 2.13E-02 1.19E-01 2.88E-01 6.39E-01 3.70E-01 2.31E-01 2.38E-01 5.26E-01 1.18E-01 1.51E-01 1.46E-03 5.07E-02 8.07E-02 1.45E-01 1.21 E-01 Sr-90 9.83E-03 7.1 OE-03 7.01 E-03 6.81 E-03 7.85E-03 2.94E-03-1.06E-02 1.95E-02-4.47E-03-4.97E-04-2.35E-03 4.55E-03 2.14E-02 7.58E-03-1.31 E-02 Identified?

Y Y Y Y Y Y Y Y Y N N Y Y Y Y Identified?

Identified?

Y N Y N Y N Y N Y N Y N Y N Y Y Y N Y N N N Y N Y Y Y N Y N Date: Date:

DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2d Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium -137 Survey Unit: Survey Unit Name: Mean: 9106-0002 Discharge Canal 1.36E-01 pCi/g Cs-i 37 Rank Percentage 0.OOE+00 1 3 %2.43E-02 2 10 %2.64E-02 3 17 %6.61 E-02 4 23 %8.09E-02 5 30 %9.30E-02 6 37 %1.16E-01 7 43 %1.23E-01 8 50 %1.63E-01 9 57 %1.69E-01 10 63 %1.75E-01 11 70 %1.84E-01 12 77 %1.98E-01 13 83 %2.47E-01 14 90 %3.81E-01 15 97 %Prepared By: Reviewed By: Date: /0 -2 ,- -0." Date: / ýr 1,g" Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cobalt -60 Survey Unit: Survey Unit Name: Mean: 9106-0002 Discharge Canal 2.07E-01 pCi/g 7.00E-01-, 6.00E-01 o. 5.OOE-01 0.0o 4.00E-01 -3.OOE-01 -u 2.00E-01 o 1.OOE-01 __0.00E+00 -0 20 40 60 80 100 Percentage Co-60 Rank Percentage 1.46E-03 1 3 %2.13E-02 2 10 %5.07E-02 3 17 %8.07E-02 4 23 %1.18E-01 5 30 %1.19E-01 6 37 %1.21E-01 7 43%1.45E-01 8 50 %1.51E-01 9 57 %2.31 E-01 10 63 %2.38E-01 11 70%2.88E-01 12 77 %3.70E-01 13 83 %5.26E-01 14 90 %6.39E-01 15 97 %65Kf 2~Y Prepared By: Reviewed By: --47, 4,.Date: Date: 10 04 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Strontium

-90 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 4.24E-03 pCi/g 2.50E-02-2.OOE-02 1.50E-02 1.OOE-02 -_ 5.00E-03 -0.00E+00 -- l 4,0 60 80 1@0 o -5.OOE-03

~ 0 ______ ___-1.OOE-02

_-1.50E-02 Percentage Sr-90 Rank Percentage

-1.31E-02 1 3 %-1.06E-02 2 10 %-4.47E-03 3 17 %-2.35E-03 4 23 %-4.97E-04 5 30 %2.94E-03 6 37 %4.55E-03 7 43 %6.81 E-03 8 50 %7.01 E-03 9 57 %7.10E-03 10 63 %7.58E-03 11 70%7.85E-03 12 77 %9.83E-03 13 83 %1.95E-02 14 90 %2.14E-02 15 97 %Prepared By: Reviewed By: Date: Date: !

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 0.207 pCi/g 5 ..T22 01....0 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency 0.10 4 27%0.20 5 33%0.30 3 20%0.40 1 7%0.50 1 7%0.60 1 7%Total 15 87%Prepared By: Reviewed By: Date: / O -5-c Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs -137 Survey Unit: Survey Unit Name: Mean: 9106-0002 Discharge Canal 0.136 pCi/g 8Cr 0*-- 2 0.10 0.20 0.30 0.40 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency 0.10 6 40%0.20 7 47%0.30 1 7%0.40 1 7%Total 15 100%6 t/- /41k4J2/Prepared By: Date: 49 -?.>>04C Date: ,' 2 T f Reviewed By: 7 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Sr -90 Survey Unit: 9106-0002 Survey Unit Name: Discharge Canal Mean: 0.004 pCi/g Upper End Observation Observation

%Value Frequency Frequency 0.00 5 33%0.02 9 60%0.04 1 7%Total 15 100%Prepared By: Date: / 0 -Z -ý ...Z Reviewed By: Date: .e 5-DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Phvsics Procedure GPP-GGGR-R512 1-000 Attachment A. Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes

urvey Unit Number
9106-0002 Survey Unit Name: WP&IR#: Discharge Canal Classification
2 TYPE I (cQ error):0.05 TYPE I (b error):0.05 Radionuclides:

Cs-137 Co-60 Sr-90 Survey Design DCGL (pCi/g): 5.38 2.59 0.62 Results Cs-137 Results Co-60 Results Sr-90 Weighted Sum (Ws) DCGL-Result Sign 2.64E-02 2.13E-02 2.13E-02 2.251E-02 9.78E-01 I 1.23E-01 1.19E-01 1.19E-01 7.56E-02 9.24E-01 1 1.98E-01 2.88E-01 2.88E-01 1.55E-01 8.45E-01 1 3.81E-01 6.39E-01 6.39E-01 3.24E-01 6.76E-01 I 1.63E-01 3.70E-01 3.70E-01 1.81E-01 8.19E-01 I 1.84E-01 2.31E-01 2.3 1E-01 1.26E-01 8.74E-01 1 6.61E-02 2.38E-01 2.38E-01 9.41 E-02 9.06E-01 I 2.47E-01 5.26E-01 5.26E-01 2.68E-01 7.32E-01 I 1.75E-01 1.1 8E-01 1.18E-01 7.38E-02 9.26E-01 I 2.431E-02 1.51E-01 1.51E-01 6.23E-02 9.38E-01 I 0.OOE+00 1.46E-03 1.46E-03 -1.67E-03 1.OOE+00 I 1.16E-01 5.07E-02 5.07E-02 4.55E-02 9.55E-01 I 9.30E-02 8.07E-02 8.07E-02 6.88E-02 9.31 E-0 I 8.09E-02 1.45E-01 1.45E-01 7.82E-02 9.22E-01 1.69E-01 1.21E-01 1.21E-01 6.57E-02 9.34E-01 Number of Positive Differences (S+): 15 Critical Value: I I Survey Unit: Meets Acceptance Criterion Performed By: _ _ __Z _ ______ Date:_____________

ndependent Review: J .4K c". Date: /Page 1 of 1 DISCHARGE CANAL SURVEY UNIT 9106-0002 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (3 Pages)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9106-0002 Dale Randall Discharge Canal 1 15 0 Sign Test Result: Not Performed 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve--0 1.0.9= 0.8 , 0.7 2. 0.6** 0.50.40.3 r: 0.2 0.1 0.zzz~z _ __ ___ I- -I _ ___ --4-__ __ ~ i1 FFFE___ __0.0 0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-of-Ratios, including baclground

--Prospective Power 1 1-beta .Actual Power.- LBGR I i Estimated Power DCGL ---- Retrospective Power 1.2 COMPASS vI.0.0 1012312006 Page 1 DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0002-002F 9106-0002-004F 9106-0002-005F 9106-0002-007F 9106-0002-008F 9106-0002-009F 9106-0002-01 OF 9106-0002-011 F 9106-0002-012F 9106-0002-013F 9106-0002-014F 9106-0002-015F 9106-0002-017F 9106-0002-018F 9106-0002-019F Type S S S S S S S S S S S S S S S Co-60 (pCi/g)0.03 0.12 0.2 0.38 0.16 0.18 0.07 0.25 0.18 0.02 0 0.12 0.09 0.08 0.17 Cs-137 (pCi/g)0.02 0.12 0.29 0.64 0.37 0.23 0.24 0.53 0.12 0.15 0 0.05 0.08 0.14 0.12 SrY-90 (pCi/g)0.01 0.01 0.01 0.07 0.01 0-0.01 0.02 0 0 0 0 0.02 0.01-0.01 Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0002-002F 9106-0002-004F 9106-0002-005F 9106-0002-007F 9106-0002-008F 9106-0002-009F 9106-0002-OIOF 9106-0002-011F 9106-0002-012F 9106-0002-013F 9106-0002-014F 9106-0002-015F 9106-0002-017F 9106-0002-018F 9106-0002-019F Type S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0.04 0.13 0.23 0.56 0.24 0.2 0.1 0.36 0.15 0.06 0 0.1 0.12 0.11 0.13 COMPASS vi .0.0 10/2312006 Page 2 COMPASS v1.0.0 10/2312006 Page 2 W& DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=15 Mean (SOR) 0.17 N/A 0.14 Median (SOR) 0.13 N/A N/A Std Dev (SOR) 0.14 N/A 0.07 High Value (SOR) 0.56 N/A N/A Low Value (SOR) 0.00 N/A N/A COMPASS vl.0.0 10/2312006 Page 3 COMPASS vl.0.0 1012312006 Page 3