ML16053A187: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 03/01/2016
| issue date = 03/01/2016
| title = Request for Additional Information, Request to Revise Technical Specification 6.8.3.j, Containment Leakage Rate Testing Program, to Extend Integrated Leak Rate Test Interval from 10 to 15 Years (CAC MF6176-MF6177)
| title = Request for Additional Information, Request to Revise Technical Specification 6.8.3.j, Containment Leakage Rate Testing Program, to Extend Integrated Leak Rate Test Interval from 10 to 15 Years (CAC MF6176-MF6177)
| author name = Regner L M
| author name = Regner L
| author affiliation = NRC/NRR/DORL/LPLIV-1
| author affiliation = NRC/NRR/DORL/LPLIV-1
| addressee name = Koehl D L
| addressee name = Koehl D
| addressee affiliation = South Texas Project Nuclear Operating Co
| addressee affiliation = South Texas Project Nuclear Operating Co
| docket = 05000498, 05000499
| docket = 05000498, 05000499
| license number = NPF-076, NPF-080
| license number = NPF-076, NPF-080
| contact person = Regner L M, NRR/DORL/LPLIV-1
| contact person = Regner L, NRR/DORL/LPLIV-1
| case reference number = CAC MF6176, CAC MF6177
| case reference number = CAC MF6176, CAC MF6177
| document type = Letter, Request for Additional Information (RAI)
| document type = Letter, Request for Additional Information (RAI)
Line 24: Line 24:


==Dear Mr. Koehl:==
==Dear Mr. Koehl:==
By letter dated April 29, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML 15128A352), as supplemented by letters dated June 29, October 8, and November 11, 2015 (ADAMS Accession Nos. ML 15198A147, ML 15293A509, and ML 15329A304, respectively), STP Nuclear Operating Company (the licensee) requested changes to the Technical Specifications for South Texas Project, Units 1 and 2. The proposed change would permit the existing Containment Integrated Leak Rate Testing frequency to be extended from 10 years to 15 years on a permanent basis. The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the information provided in your application and determined that additional information, as described in the enclosure to this letter, is required to complete the review. A draft version of the request for additional information (RAI) was provided to Mr. Lance Sterling of your staff via e-mail on February 18, 2016 (ADAMS Accession No. ML 16050A026).
By letter dated April 29, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15128A352), as supplemented by letters dated June 29, October 8, and November 11, 2015 (ADAMS Accession Nos. ML15198A147, ML15293A509, and ML15329A304, respectively), STP Nuclear Operating Company (the licensee) requested changes to the Technical Specifications for South Texas Project, Units 1 and 2. The proposed change would permit the existing Containment Integrated Leak Rate Testing frequency to be extended from 10 years to 15 years on a permanent basis. The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the information provided in your application and determined that additional information, as described in the enclosure to this letter, is required to complete the review. A draft version of the request for additional information (RAI) was provided to Mr. Lance Sterling of your staff via e-mail on February 18, 2016 (ADAMS Accession No. ML16050A026).
The questions were discussed with your staff during a conference call the same day. The RAI was revised and a draft copy of the enclosed request for additional information (RAI) was provided to Mr. Lance Sterling of your staff via e-mail on February 24, 2016 (ADAMS Accession No. ML 16057A032).
The questions were discussed with your staff during a conference call the same day. The RAI was revised and a draft copy of the enclosed request for additional information (RAI) was provided to Mr. Lance Sterling of your staff via e-mail on February 24, 2016 (ADAMS Accession No. ML16057A032).
The questions were discussed with your staff during a conference call on February 25, 2016. Your response is requested by March 21, 2016, to allow the NRC staff enough time to make a regulatory decision on your license amendment request by your requested date of April 30, 2016. If you are unable to provide a satisfactory RAI response by March 21, 2016, the staff is unlikely to meet your requested completion date. D. Koehl If you have any questions, please contact me at 301-415-1906 or vis e-mail at Lisa. Reg ner@nrc.gov.
The questions were discussed with your staff during a conference call on February 25, 2016. Your response is requested by March 21, 2016, to allow the NRC staff enough time to make a regulatory decision on your license amendment request by your requested date of April 30, 2016. If you are unable to provide a satisfactory RAI response by March 21, 2016, the staff is unlikely to meet your requested completion date. D. Koehl If you have any questions, please contact me at 301-415-1906 or vis e-mail at Lisa. Reg ner@nrc.gov.
Docket Nos. 50-498 and 50-499  
Docket Nos. 50-498 and 50-499  
Line 31: Line 31:
==Enclosure:==
==Enclosure:==


Request for Additional Information cc w/encl: Distribution via Listserv Lisa M. Regner, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO EXTEND THE CONTAINMENT INTEGRATED LEAK RATE TEST FREQUENCY STP NUCLEAR OPERATING COMPANY SOUTH TEXAS PROJECT. UNITS 1 AND 2 DOCKET NOS. 50-498 AND 50-499 By letter dated April 29, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML 15128A352), as supplemented by letters dated June 29, October 8, and November 11, 2015 (ADAMS Accession Nos. ML 15198A147, ML 15293A509, and ML 15329A304, respectively), STP Nuclear Operating Company (the licensee) requested changes to the Technical Specifications for South Texas Project (STP), Units 1 and 2. The proposed change would permit the existing Containment Integrated Leak Rate Testing frequency to be extended from 10 years to 15 years on a permanent basis. The U.S. Nuclear Regulatory Commission staff has reviewed the information provided in your application and determined that the following additional information is required to complete the review. SCVB RAI: The STP Updated Final Safety Analysis Report (UFSAR) Section 6.2.1.3, "Mass and Energy Release Analyses for Postulated Loss of Coolant Accidents," states the use of the Westinghouse WCAP-10325-P-A methodology for loss-of-coolant accident (LOCA) mass and energy release analysis.
Request for Additional Information cc w/encl: Distribution via Listserv Lisa M. Regner, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO EXTEND THE CONTAINMENT INTEGRATED LEAK RATE TEST FREQUENCY STP NUCLEAR OPERATING COMPANY SOUTH TEXAS PROJECT. UNITS 1 AND 2 DOCKET NOS. 50-498 AND 50-499 By letter dated April 29, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15128A352), as supplemented by letters dated June 29, October 8, and November 11, 2015 (ADAMS Accession Nos. ML15198A147, ML15293A509, and ML15329A304, respectively), STP Nuclear Operating Company (the licensee) requested changes to the Technical Specifications for South Texas Project (STP), Units 1 and 2. The proposed change would permit the existing Containment Integrated Leak Rate Testing frequency to be extended from 10 years to 15 years on a permanent basis. The U.S. Nuclear Regulatory Commission staff has reviewed the information provided in your application and determined that the following additional information is required to complete the review. SCVB RAI: The STP Updated Final Safety Analysis Report (UFSAR) Section 6.2.1.3, "Mass and Energy Release Analyses for Postulated Loss of Coolant Accidents," states the use of the Westinghouse WCAP-10325-P-A methodology for loss-of-coolant accident (LOCA) mass and energy release analysis.
Westinghouse Electric Company LLC (Westinghouse) has issued Nuclear Safety Advisory Letters (NSALs)-06-6, 5, and 2, and lnfoGram (IG)-14-1 to report errors in this methodology.
Westinghouse Electric Company LLC (Westinghouse) has issued Nuclear Safety Advisory Letters (NSALs)-06-6, 5, and 2, and lnfoGram (IG)-14-1 to report errors in this methodology.
Also, a new methodology (GOTHIC) is used for the LOCA containment analysis for which the mass and energy input needs to be corrected based on the above NSALs and the lnfoGram.
Also, a new methodology (GOTHIC) is used for the LOCA containment analysis for which the mass and energy input needs to be corrected based on the above NSALs and the lnfoGram.
Line 41: Line 41:


Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL4-1 Reading RidsACRS_MailCTR Resource RidsNrrDorllpl4-1 Resource RidsNrrDssScvb Resource RidsNrrPMSouthTexas Resource RidsNrrLAJBurkhardt Resource RidsRgn4MailCenter Resource ADAMS Accession No. ML 16053A187 Sincerely, IRA/ Lisa M. Regner, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation  
PUBLIC LPL4-1 Reading RidsACRS_MailCTR Resource RidsNrrDorllpl4-1 Resource RidsNrrDssScvb Resource RidsNrrPMSouthTexas Resource RidsNrrLAJBurkhardt Resource RidsRgn4MailCenter Resource ADAMS Accession No. ML16053A187 Sincerely, IRA/ Lisa M. Regner, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation  
*via email OFFICE NRR/DORL/LPL4-1  
*via email OFFICE NRR/DORL/LPL4-1  
/PM NRR/DORL/LPL4-1/LA NRR/DSS/SCVB/BC NRR/DORL/LPL4-1  
/PM NRR/DORL/LPL4-1/LA NRR/DSS/SCVB/BC NRR/DORL/LPL4-1  
/BC NRR/DORL/LPL4-1/PM NAME LRegner (MWatford for) JBurkhardt*
/BC NRR/DORL/LPL4-1/PM NAME LRegner (MWatford for) JBurkhardt*
RDennig* RPascarelli LRegner DATE 2/25/16 2/25/16 2/25/16 03/01 /16 03/01/16 OFFICIAL RECORD COPY}}
RDennig* RPascarelli LRegner DATE 2/25/16 2/25/16 2/25/16 03/01 /16 03/01/16 OFFICIAL RECORD COPY}}

Revision as of 08:40, 20 June 2019

Request for Additional Information, Request to Revise Technical Specification 6.8.3.j, Containment Leakage Rate Testing Program, to Extend Integrated Leak Rate Test Interval from 10 to 15 Years (CAC MF6176-MF6177)
ML16053A187
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 03/01/2016
From: Lisa Regner
Plant Licensing Branch IV
To: Koehl D
South Texas
Regner L, NRR/DORL/LPLIV-1
References
CAC MF6176, CAC MF6177
Download: ML16053A187 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Dennis L. Koehl President and CEO/CNO STP Nuclear Operating Company South Texas Project P.O. Box 289 VVadsworth, TX 77483 March 1, 2016

SUBJECT:

SOUTH TEXAS PROJECT, UNITS 1 AND 2 -REQUEST FOR ADDITIONAL INFORMATION RELATED TO A LICENSE AMENDMENT REQUEST TO EXTEND THE CONTAINMENT INTEGRATED LEAK RATE TEST FREQUENCY (CAC NOS. MF6176 AND MF6177)

Dear Mr. Koehl:

By letter dated April 29, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15128A352), as supplemented by letters dated June 29, October 8, and November 11, 2015 (ADAMS Accession Nos. ML15198A147, ML15293A509, and ML15329A304, respectively), STP Nuclear Operating Company (the licensee) requested changes to the Technical Specifications for South Texas Project, Units 1 and 2. The proposed change would permit the existing Containment Integrated Leak Rate Testing frequency to be extended from 10 years to 15 years on a permanent basis. The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the information provided in your application and determined that additional information, as described in the enclosure to this letter, is required to complete the review. A draft version of the request for additional information (RAI) was provided to Mr. Lance Sterling of your staff via e-mail on February 18, 2016 (ADAMS Accession No. ML16050A026).

The questions were discussed with your staff during a conference call the same day. The RAI was revised and a draft copy of the enclosed request for additional information (RAI) was provided to Mr. Lance Sterling of your staff via e-mail on February 24, 2016 (ADAMS Accession No. ML16057A032).

The questions were discussed with your staff during a conference call on February 25, 2016. Your response is requested by March 21, 2016, to allow the NRC staff enough time to make a regulatory decision on your license amendment request by your requested date of April 30, 2016. If you are unable to provide a satisfactory RAI response by March 21, 2016, the staff is unlikely to meet your requested completion date. D. Koehl If you have any questions, please contact me at 301-415-1906 or vis e-mail at Lisa. Reg ner@nrc.gov.

Docket Nos. 50-498 and 50-499

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv Lisa M. Regner, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO EXTEND THE CONTAINMENT INTEGRATED LEAK RATE TEST FREQUENCY STP NUCLEAR OPERATING COMPANY SOUTH TEXAS PROJECT. UNITS 1 AND 2 DOCKET NOS. 50-498 AND 50-499 By letter dated April 29, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15128A352), as supplemented by letters dated June 29, October 8, and November 11, 2015 (ADAMS Accession Nos. ML15198A147, ML15293A509, and ML15329A304, respectively), STP Nuclear Operating Company (the licensee) requested changes to the Technical Specifications for South Texas Project (STP), Units 1 and 2. The proposed change would permit the existing Containment Integrated Leak Rate Testing frequency to be extended from 10 years to 15 years on a permanent basis. The U.S. Nuclear Regulatory Commission staff has reviewed the information provided in your application and determined that the following additional information is required to complete the review. SCVB RAI: The STP Updated Final Safety Analysis Report (UFSAR) Section 6.2.1.3, "Mass and Energy Release Analyses for Postulated Loss of Coolant Accidents," states the use of the Westinghouse WCAP-10325-P-A methodology for loss-of-coolant accident (LOCA) mass and energy release analysis.

Westinghouse Electric Company LLC (Westinghouse) has issued Nuclear Safety Advisory Letters (NSALs)-06-6, 5, and 2, and lnfoGram (IG)-14-1 to report errors in this methodology.

Also, a new methodology (GOTHIC) is used for the LOCA containment analysis for which the mass and energy input needs to be corrected based on the above NSALs and the lnfoGram.

The licensee indicated that the three Westinghouse NSALs were corrected and incorporated into the new LOCA containment analysis and the analysis results have been incorporated into the UFSAR. 1. Please describe any changes in inputs and assumptions in the reanalysis that could potentially reduce the conservatism in the previous analysis.

Please describe which UFSAR sections and figures contain the revised results of the LOCA mass and energy releases, containment pressure response, and Equipment Qualification pressure/temperature response analyses.

Provide a brief description of the changes from the previous analysis results. Enclosure 2. The information provided in the IG-14-1 is generic. Please describe STP specific analysis/evaluations performed to determine the applicability of the errors reported in the lnfoGram to STP and its impact on the current analysis of record. D. Koehl If you have any questions, please contact me at 301-415-1906 or via e-mail at Lisa. Reg ner@n re. gov. Docket Nos. 50-498 and 50-499

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC LPL4-1 Reading RidsACRS_MailCTR Resource RidsNrrDorllpl4-1 Resource RidsNrrDssScvb Resource RidsNrrPMSouthTexas Resource RidsNrrLAJBurkhardt Resource RidsRgn4MailCenter Resource ADAMS Accession No. ML16053A187 Sincerely, IRA/ Lisa M. Regner, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

  • via email OFFICE NRR/DORL/LPL4-1

/PM NRR/DORL/LPL4-1/LA NRR/DSS/SCVB/BC NRR/DORL/LPL4-1

/BC NRR/DORL/LPL4-1/PM NAME LRegner (MWatford for) JBurkhardt*

RDennig* RPascarelli LRegner DATE 2/25/16 2/25/16 2/25/16 03/01 /16 03/01/16 OFFICIAL RECORD COPY