Line 3: Line 3:
| issue date = 08/04/1995
| issue date = 08/04/1995
| title = Forwards Books 1 & 2 of ISI Outage Summary Rept SSES Unit 1 8th Refuel Outage, Completed on 950714
| title = Forwards Books 1 & 2 of ISI Outage Summary Rept SSES Unit 1 8th Refuel Outage, Completed on 950714
| author name = BYRAM R G
| author name = Byram R
| author affiliation = PENNSYLVANIA POWER & LIGHT CO.
| author affiliation = PENNSYLVANIA POWER & LIGHT CO.
| addressee name =  
| addressee name =  

Revision as of 05:21, 18 June 2019

Forwards Books 1 & 2 of ISI Outage Summary Rept SSES Unit 1 8th Refuel Outage, Completed on 950714
ML18017A282
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 08/04/1995
From: Byram R
PENNSYLVANIA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17158A807 List:
References
PLA-4343, NUDOCS 9508100123
Download: ML18017A282 (249)


Text

PRIORITY MCCELERATED RIDS PROCESSING 0 REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)ACCESSION NBR:9508100123 DOC.DATE: 95/08/04'OTARIZED:

NO DOCKET FACIL:50-387 Susquehanna Steam Electric Station, Unit 1, Pennsylva 05000387 p AUTH.NAME AUTHOR AFFILIATION BYRAM,R.G.

Pennsylvania Power&Light Co.RECIP.NAME RECIPIENT AFFILIATION R Document Control Branch (Document Control Desk)

SUBJECT:

Forwards Books 1&2 of"ISI Outage Summary Rept SSES Unit 1 I.8th Refuel Outage," completed on 95071'4.DISTRIBUTION CODE: A047D COPIES RECEIVED:LTR J ENCL f SIZE: l TITLE: OR Submittal:

Inservice/Testing/Relief from ASME Code-GL-89-04 R NOTES 05000387 RECIPIENT ID CODE/NAME PD1-2 LA POSLUSNY,C INTERNAL: ACRS BNTER 1 NRR/DE/EMEB OGC/HDS2 EXTERNAL: LITCO ANDERSON NOAC NOTES: COPIES LTTR ENCL 1 1 1 1 6 0 1 1 1 1 1 0 1 1 1 1 1 1 RECIPIENT ID CODE/NAME PD1-2 PD AEOD/SPD/RAB NRR/DE/EMCB'UDOCS-ABSTRACT RES/DSIR/EIB LITCO RANSOME,C NRC PDR COPIES-LTTR ENCL 1 1 1 1 1 1 1 1 1 1-1 1 1 1~D N NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5DS (415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!TOTAL NUMBER OF COPIES REQUIRED: LTTR 21 ENCL 14 Pi~~%J'I

~I'O Pennsylvania Power 8 Light Company Two North Ninth Street~Allentown, PA 18101-1179~215/774-5151 Robert G.Byrarn Senior Vice President-Nuclear 610I774-7502 Fax: 610/774-5019

<UC 04>995 U.S.Nuclear Regulatory Commission Attn: Document Control Desk Mail Station P1-137 Washington, DC 20555\SUSQUEHANNA STEAM ELECTRIC STATION UNIT 1 EIGHTH REFUELING AND INSPECTION OUTAGE ISI

SUMMARY

REPORT 4 Docket No 50-387 Attached for your use is a copy of the Susquehanna Steam Electric Station Inservice Inspection Outage Summary Report for the Unit 1 Eighth Refueling and Inspection Outage.A copy of this report has also been sent to the Commonwealth of Pennsylvania.

If you have any questions, please contact C.T.Coddington at (610)774-7531.Very truly yours, Atta cc: NRC Region I (w/o)Ms.M.Banerjee NRC Sr.Resident Inspector-SSES (w/o)Mr.C.Poslusny, Jr.NRC Sr.Project Manager-OWFN (w/o)'rr508iOOi23 950804 PDR ADOCK 05000387 Q PDR II 0 A 4v~~ty N I 1(1"~'

Docket'Accession 4 e~a~~Date Regulatory Docket File INSERVrCE>NSPEer>ON Of Ltt'UTAGE S ARY REPORT Pennsylvania Power&Light Company Two North Ninth Street Allentown, PA 18101-1179 COVER PAGE Susquehanna Steam Electric Station P.O.Box 467 Berwick, PA 18603 UNIT 1-8TH REIi VEL OUTAGE COMPLETION DATE-July 14, 1995 COMMERCIAL SERVICE DATE-June 8, 1983 COPY BOOK20F2 4 f~giagoQ"~idf38'3JQA

'!lJ t~, eisG:!i-I.exooG go(slurpR rVrODIVIC~nON rWSr~r,I.LIOW Ga.OUP NIS-2 FORMS WORK ABSTRACT The Modification Installation Group is responsible for preparing Construction Work Authorizations (work packages)for fabrication and installation of design changes in accordance with ASME Section XI and the National Board Inspection Code.This work is documented on NIS-2 Forms, or on R-1 Forms, which are submitted herewith.MODIFICATION INSTALLATION GROUP Design Change Packages for ASME Section Xl (Class 1, 2 and 3), and the National Board Inspection Code, installed in Unit 1 since the completion of the Seventh Refueling Outage through completion of the Eighth Refueling Outage are summarized below: DESIGN CHANGF SYSTEM/CLASS PACKAGE NUMBER DESCRIPTION 90-9095 94-3018 94-3021 A 94-3021D 94-3021 E 94-3021 F 93-3090A, B, C 8 D 93-3092A 8 B 93-3077 89-9153 B 94-3023A&D 93-3069 93-3059A, B&C 94-9088 95-9025 89-3018D 93-3086 93-3086 125A III 139 139*139 139*139" 149A II 151A II 152B II 154A III 154A III 155B II 162A I 164A I 173A II 173A II 184*184" Modify various pipe supports Install sight glasses in G condensate demineralizer Install sight glasses in A condensate demineralizer Install sight glasses in D condensate demineralizer Install sight glasses in E condensate demineralizer Install sight glasses in F condensate demineralizer Replace bonnets on valves 151 F031A, B, C 8 D Replace bonnets on valves 152F003A, B, C 8 D Replace disc in valve HV-1 55F001 Modify various pipe supports Installed new piping to RHR Pump Motor Oil Coolers Modify various pipe supports Installed reactor water level condensing chambers Modified pipe support SP-DCA-1 51-H2008 Removed valve actuator supports Installation of new CRM piping Added nozzles in 1T105A Added nozzles in 1T105B Repair of an ASME section Vill vessel in a non-nuclear system.

125A lll FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 8 Light Co.Name Two North Ninth St., Allentown, PA 18101 Date Sheet May 5, 1995 1 of 2.Plant Susquehanna Steam Electric Station Name Unit One 3.Work Performed by Penns Ivania Power 8 Light Co.Name PO Box 467, Befwick, PA 18603 Address DCP 90-9095, WA C33306, C33307 Repair Orgartlzatrerr P.O.Na, Job Na, etd, Type Code Symbol Stamp None'Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentlllcation of System CONTAINMENT INSTRUMENT GAS SYSTEM 125A CLASS III 5.(a)Applicable Construction Code III 19 71 Edition, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 thru Vtf80 6.Identication of Components Repaired or Replaced and Replacement Components Addenda, Code Case and IWF-7000, Winter 1982 Addenda Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT BECHTEL BECHTEL BECHTEL N/A NIA NIA N/A NIA SPNCC-139-H2016 SP-KCC-139-H2003 1982 SPCCC-102-H1 19S2 REPAIRED REPLACED REPLACED NO NO NO PIPE SUPPORT PIPE SUPPORT PP+L BECHTEL NIA NIA N/A SP-HCC-139-H2003 SP-CCC-101-H2004 19S2 REPLACED 1994 REPLACEMENT NO 7.Description of Work Pipe supports were modified and repaired to su ort ipin rework 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure NONE REQUIRED Other Pressure psl Test Temp.ep NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is SN in.x 11 in., (2)Informa tion ln items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(12I82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)9 Remarks This NIS-2 is being submitted to report pipe support work that should have been included in an Appticabte Manulacturer's Data Reports to be attached NIS-2 fors stem125A-III reviousl submittedwith the Unit1 Seventh Outa e Summa Re ort.CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.repair or replacement Type Code Symbol Stamp N/A Cernlicate of Authorization No.N/A Expiration Date N/A Signed Own r or ers Oesltinee, Trtte VP&uc Operations Date ,19 P5 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel inspectors and the State orProvinceof P S ANIA andemployedby A RIG TMUTUA INSU CECO.of THAM MASSAC USETTS have inspected thegrgenents described in this Owners Report during the period to 0-p-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ovmer's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inJury or property damage or a loss of any kind arising from or connected with this inspection.

Date Inspector's Signature Commissions AB S6k~X4b/5'ational Board, State, Province, and Endorsements FORM R-1, REPORT OF WELDED QX REPAIR OR Q ALTERATION as required by the provisions of the National Board Inspection Code 139 1.Work performed by 2.Owner (name)3.Location of installation Penns Ivania Power and Li ht (name or re petr or alteradon or()anizatton)

Two North Ninth Street, Allentown.

Pa.18101 (address)Penns Ivania Power and Li ht Two North Ninth Street, Allentown.

Pa.18101 (address)Su uehanna Steam Electric Station (name)P.O.Box 467, Be(wick, Pa.18603 DCP 9430(8/WAt)C43803 (p.o.nolob no., etc.)Allied Steel Products Co oration (address)unit Ident(((cat(on:

Condensate Oemlneralizer Name of original manufacturer (bolter, pressure vessel)5.Identlfylng nos: W-8496-C 7734 PA469348 1F-106 G 1975 (mrr's serial no.)(ortt)lnal Nadonal Board no.)()unsdtctton no.)(otnet)(rear bulk)5.Description of work: installed two J.G.Papailias Co.Inc., Slghtglasses Parttt NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate sheet, or sketch tr necessar)t)

Pressure test, lf applied 520 psl Ref)hcerntmt Parts.Attached ae Manufacturers'Patthl Data Reports property lntfenti5ed and signed by Authorlnxf hspectors for the tolowing items of this repott NONE 8.Remarks: NONE (name or pan, Item number, mll's.name and ldendrrtns stamp)Th)s form may be obtained from the Nathnal Board of Boiler and Pressure Vessd Inspectors, 1055 Crupper AveColumbus, OH 43229 DESIGN CERTIFICATION The undersigned certifies that the statements made in this report are correct and that the design changes described ln this report conform to the requirements of the National Board Inspection Code.ASME Certificate of Authorization no.to use the symbol expires 19, Date 19 (name of organlzadon)

Signed (alrthonzed fepresentadve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Commlsion issued by the National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of and employed by of has examined the design change as described in this report and ver(Iles that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board inspection Code.By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or knplled, concerning the work described in this report.Futthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such I(ability as may be provided In a policy of in surance which the undersigned's insurance company may Issue upon said object and then only in accordance with the terms of said policy.Date 19 gtgnee (Authortzed Inspector)

Commissions (National Board (IncL endorsements), state, prov., and no.)CONSTRUCTION CERTIFICATION The undersigned ce)tifles that the statements made in this report are correct and that all construction and workmanship on this R I conform to the National Board Inspection Code.(repair or alteration)

Certificate of Authorization no.A'o use the NI Date~~3/19~$Penna tVentePDWerendLi ht (name or repair organ(zadon) symbol expires 19 Sl ned (a ortzed representadve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Commision issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of NS Nl and employed by G M A NSU NC CO of SS has inspected the work described In this report on Ot 19~~and state that to the best of my knowledge and belief this work has been done In accordance with the National Board Inspection Code.By signing this certlflcatee neither the undersigned nor my employer makes any warrenty, expressed or implied, concerning the work described in this report.Furthermore, neither the undersigned nor my employer shall be liable ln any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided ln a policy of in surance which the undersigned's Insurance corn y Issue upon said object and then only In accordance with the terms of said policy.Date 19~~Signed (Authorized Inspector)

Commlsslons 4 5'Nadonal 8oard (IncL endorsements).

state, provand no.)

FORM R-1, REPORT OF WELDED[7X REPAIR OR ALTERATION as required by the provisions of the National Board Inspection Code 139 1~Work performed by 2.Owner (name)3.Location of installation Penns Ivania Power and Li ht (name of repair or arteratlon organlzatton)

Two North Ninth Street, Allentown, Pa.18101 (address)Penns lvania Power and Li ht Two North Ninth Street, Allentown, Pa.18101 (address)Sus uehanna Steam Electric Station (name)P.O.Box 467, Be(wick, Pa.18603 DCP 944021A/WA¹C43506 (p.O.no.,)ob no., eto.)Allied Steel Products Co oration (address)4.Unit Identification:

Condensate Dentineralizer Name of original manufacturer (boiler, pressure vesset)6, Identifying nos: K74-70 7590 PA469342 1F-106A 1975 (mfrs serial no.)(ortglnal)(adonai soard no.)0uttsdlotlon no.)(other)~(year boih)6.Description of work: Installed two J.G.Papaillas Co.Inc., Slghtglasses Part¹'NW125DW/HP/316/CS/CS/TBS/NAS (use baott~separate sheeb or sttetoh If neoessaly)

Pressure test, If applied 550:.psl 7.Replacement Parts.Atbtched are Manufacttsers'Parti)i Data Reports propedy hdenNed and s)gnedbyAuthodzed hspectors for the folowi)g items of this report NONE 8.Remarks: NONE (name or part, Item number, mfrs.name and Idenutytnt) stamp)This form may be obtained from the Nathnal Board of Boiler and Pressure Vessel Inspectors, 1066 Crupper Aveco(umbus, OH 4322S DESIGN CERTIFICATION The undersigned

'certifies that the statements made in this report are correct and that the design changes described In this report conform to the requirements of the National Board Inspection Code.AS ME Certificate of Authorization no.to use the symbol expires 19, gate 19 (name or organlzauon)

Signed (atnnortzed representaave)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Comm)sion issued by the National Board of Boiler and Pressure Vessel inspectors and certificate of com-petency Issued by the state or province of and employed by of has examined the design change as described in this report and verifies that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board Inspection Code.By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or implied, concerning the work described ln this report.Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided ln a policy of In surance which the undersigned's insurance company may Issue upon said object and then only in accordance with the terms of said policy.Sale 19 Slgeed (Autnorlzed Ins pector)Commissions (Nauonal Board (Ind.endors<<nants), stats.prov., and no.)CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made in this report are correct and that all construction and workmanship on this R I conform to the National Board Inspection Code.(repair or altered on)Certificate of Authorization no.Oate~d&I 19 95 to use the Penns Ivania Power and Li ht (name or repair organlzatlon) symbol expires Sign 19 (a orlzed representadve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Comm(sion issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of P S Nl and employed by A A SU NC CO.of A S has inspected the work described In this report on 192 and state that to the best of my knowiedge and belief this work has been done In accordance with the National Board Inspection Code.By signing this celtificatee neither the undersigned nor my employer makes any warrenty, expressed or Implied, concerning the work described'in this report.Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal Injury, property damage or toss of any kind arising from or connected with this inspection, except such liability as may be provided in a policy of in surance which the undersigned's Insurance compa issue upon said object and then only in accordance with the terms of said policy.Date 19~~Signed Commissions (Madonal Board (Incl.endorsements).

state.prov., and no.)(Atnnortzed Inspector)

FORM R-1, REPORT OF WELDED QX REPAIR OR Q ALTERATION as required by theprovisions of the National Board Inspection Code 139'I 1.Work performed by 2.Owner (name)3.Location of installation Penns Ivania Powerand Li ht (name of repair oractecauon ort)an(tauon)

Two North Ninth Street, Allentown, Pa.18101 (address)Penns Ivania Power and Li ht Two North Ninth Street, Allentown, Pa.18101 (address)Sus uehanna Steam Electric Station (name)P.O.Box 467, Be(wick, Pa.18603 OCP 9430210/WA¹C43452 (p.o.nojob no..etc.)(address)4.unit Identification:

Condensate Defnineralizer Name of original manufacturer Allied Steel Products Co oration (boiler, pressure vessel)6.(dentlfylng nos: K74-70 7583 PA469345 1F-1 06D 1975 (mfrs serial no.)(octgtnat Kauonat eoacd no.)()uctsdlctton no.)(other)(year built)().Descr(ption of work;Installed two J.G.Papaillas Co.Inc., Slghtglasses Part4 NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate sneeb or sketch If necessaly)

Pressure test, if applied 500 psl 7.Replacement Parts.Attached ae Mawfactufefs'PaftktlOata Reports propedy ktttenti5ed and signed by Att(hoftzedktspectofsforthe items of this report NONE 8.Remarks: NONE (name of pact, Item number, cnh's.name and tdenttfytnt) stamp)This form may be obtained from the 44athnal Board of Bo()er and Pressure Vessel inspectors, 10(M Crupper Avecolumbus, OH 43229 QESIGN CERTIFICATION The undersigned celt(iles that the statements made in this report are correct and that the design changes described In this report conform to the requirements of the National Board inspection Code.ASME Certificate of Authorization no.to use the 19 symbol expires Sate 19 (name of organizadon)

Signed (authorized rsprsentatlvs)

CERTIFICATE OF REV(EW OF OES(GN CHANGE The undersigned, holding a valid Commision issued by the National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency Issued by the state or province of and employed by of has examined the design change as described In this report and verNes that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board inspection Code.By signing this certificate, neither the undersigned nor his employer makes any waaenty, expressed or Implied, concerning the work described (n this report.Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal injury, property damage or loss of any kind arising from or connected w(th this inspection, except such liability as may be provided in a po8cy of in surance which the undersigned's insurance company may Issue upon said object and then only In accordance with the terms of said policy.Sate 19 Staaed (Alnhottzed Itlapsctor)

Conan(ss(ons

.!(National eoard (IncL endoraementa), state, prov., an4 no.)CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made In this report are correct and that all construction and workmanship on this A(conform to the National Board Inspection Code.(repair or altsladon)

Certificate of Authorization no.Sate~~>l 19~~Nl to use the Penns Ivania Power and Li ht (name of repair organtzadon) symbol expires Sign 19 uthorlzed reprentatlve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Convnls(on issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency Issued by the state or province of NS and employed by G V NC CO of THA ASS has inspected the work described in this report on 19~a and state that to the best of my knowledge and belief this work has been done in accordance with the National Board inspection Code.By signing this certilicate, neither the undersigned nor my employer makes any warrenty, expressed or Implied, concerning the work described in this report.Furthermore, ne(ther the undersigned nor my employer shall be liable ln any manner for any personal injury, property damage or loss of any kind arising from or connected with this Inspect(on, except such liability as may be provided in a policy of in surance which the undersigned's insurance company may issue upon said object and then only In accordance with the terms of said policy.Oat~~19~~S(gned (Authorized Inspector)

Comfnlsslons (Madonal 8oanl (In4.endorsementa).

stats, prov., and no.)

FORM R-1, REPORT OF WELDED QX REPAIR OR Q ALTERATION as required by the provisions of the National Board inspection Code 139 1.Work performed by 2.Owner (name)3.Location of installation Penns Ivania Power and Li ht (name of repair or atteratt on organlzatt on)Two North Ninth Street, Allentown.

Pa.18101 (address)Penns lvania Power and Li ht Two North Ninth Street, Allentown.

Pa.18101 (address)Sus uehanna Steam Electric Station (name)P.O.Box 467, Be(vfick, Pa.18603 OCP 94402(E/WA¹C43434 (p.o.no..)ob no., etc.)(address)4.Unit(den(I(teat(on:

Condense(eDefninefa~<er Nameoforlglnalmanufacturer Allied Steel Products Co oration (holler, pressure vessel)5.Identifying nos: W-8496-B 7717 PA469346 1F-106E 1975 (mh's serial no.)(ortglnal Nattonat eoard no.)()urtsdlcdon no.)(other)(rear bout)5.Description of work: Installed two J.G.Papailias Co.Inc., Sightglasses Part¹NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate sheer.or sketch lr necessary)

Pressure test, if a pplled 500 psi Rep(acenslt Parts.A(tached ae Mfstuhchsers'Pafth(Data Repotts property i)tketi5ed and sk)nedby Mhortzedk)specters for the folowitg Rems of(tis report NONE 8.Remarks: NONE (name of part, Item number, mfrs.name and Identhytng stamp)This fonnmay be obtained from the National Board of Bo(ler and Pressure Vessel inspectors, 1055 Crupper AveColumbus, OH 43229 symbol expires 19 DESIGN CERTIFICATtON The undersigned certifies that the statements made In this report are correct and that the design changes described ln this report conform to the requirements of the National Board inspection Code.ASME Certificate of Authorization no.ta Use the gate 19 (name of organlzadon)

Signed (aumorlzed representauve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Cortxntston Issued by the National Board of Boiler and Pressure Vessel inspectors and certificate of com-petency Issued by the state or province of and employed by of has examined the design change as described in this report and verities that to the best of his knowledge and belief such change compiles with the applicable requirements af the National Board Inspection Code.By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or Implied, concerning the work described ln this report.Furthermore, neither the undersigned nor my employer shall be liable ln any manner for any personat injury, property damage or loss of any kind arising from or connected with this Inspection, except such liability as may be provided In a policy of ln surance which the undersigned's insurance company may Issue upon said object and then only In accordance with the terms of said policy.gate 19 gtgeed (Autnortzed Inspector)

Commlsstans (Nadonal Board (IncL endorsements), state.prov., and no.)CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made in this report are correct and that all construction and workmanship on this R conform to the National Board inspection Code.(repair or alteradon)

Certificate of Authorization no.Oate~~B/1995 M/A to use the Penns Ivania Power and Li t (name of repair organlzadon) symbol expires SI (authorized representative)

CERTtFICATE OF INSPECTION The undersigned, holding a vagd Commislan issued by The National Board of Boiler and Pressure Vessei Inspectors and certificate of com-petency Issued by the state or province of S I and employed by G SU NCE CO of A A ASS hasinspectedtheworkdescrtbcdinthis report on 19~and state that to the best of my knowledge and belief this work has been done in accordance with the National Board inspection Code.By signing this certificate, neither the undersigned nor my employer makes any warrcnty, expressed or implied, concerning the work described in this report.Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided In a policy of in surance which the undersigned's insurance compa y Issue upon said abject and then anly In accordance with the terms of said pa(Icy.Date 19~Signed (A orlzed Inspector)

Commissions (katlonal Board (Incl.endorsements), state, prov., and no.)

FORM R-1, REPORT OF WELDED X REPAIR OR Q ALTERATION as required by the provisions of the National Board Inspection Code 139 Work performed by 2.Ovmer (nemo)3.Location of installation Penns Ivania Power and Li ht (name of repair or alteradon ort)antsadon)

Two North Ninth Street, Allentown.

Pa.18101 (address)Penns lvania Power and Li ht Two North Ninth Street, Allentown, Pa.18101 (address)Sus uehanna Steam Electric Station (nemo)P.O.Box 467, Be(wick, Pa.18603 DCP 944021F/WA()C43419 (P.O.no)ob noetc.)Allied Steel Products Co oration (address)4.Unit identification:

Condensate Demlnefartzer Name of original manufacturer (boiler, pressure vessel)6.Identifying nos: W-8496-A 7729 PA469347 1F-106F 1975 (mfrs sertat no.)(ont)Inst ffadonat eoard no.)Ourlsdlctlon no.)(other)(year bulk)6, Descf(ptlon of)Nork;Installed two J.G.Papailias Co.Inc.~Sightglasses Part¹NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate shor, or sketch If necossal)f)

Pressure test, if applied 550:.ps(Rep/aceamtt Parts.Attached ae Mawfacttatss'Paftktl Data Repotts property ktdeftd(led and signedby Au(hoftzedktspectofs for the items of th(s report NONE 8, Remarks:-NONE (name of part, Item number, mh's.name and tdenetylnt) stamp)This form may be obtained from the Nathnal Board of Boiler and Pressure Vesse)Inspectors, 1056 Crupper Avecolumbus, OH 43229 DESIGN CERTIFICATION The undersigned celtifles that the statements made In this report are correct and that the design changes described in this report conform to the requirements of the National Board inspect)on Code.ASME Certificate of Authorizat)on no.to use the symbol expires 19 Date 1S (narll~of organlzadon)

Signed (atnhorlzed representadve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Const)Is(on issued by the National Board of Boiler and Pressure Vessel Inspectors and cerdflcate of com-petency issued by the state or province of and employed by of has examined the design change as described in this report and verifies that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board Inspection Coda By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or knplied, concerning the work described in this report.Furthermore, neither the undersigned nor my employer shall be liable ln any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such Ilabllity as may be provided in a poHcy of ln surance which the undersigned's insurance company may Issue upon said object and then only in accordance with the terms of said policy.Date 1S Stgeee (Authortzed Inspector)

Comnissions (National eoard (Inct.en4orsements), state.prov., an4 no.)CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made In this report are correct and that all construction and workmanship on this I conform to the National Board Inspection Code.(repair or alta radon)Certificate of Authorization no.Date~>>~ta g~to use the Penns Ivania Power and Li ht (name of repair organlzadon) symbol expires SI authorized representative)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Commlsion Issued by The National Board of Boiler and Pressure Vesse nspectors and certificate of com-petency Issued by the state or province of Nl and employed by SU CE CO of ASS has inspected the work described in this report on 19~and state that to the best of my knowledge and begef this work has been done In accordance with the National Board Inspection Code.By signing this certificate, neither the undersigned nor my employer makes any warrenty, expressed or knpged, concerning the work described in this report.Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such Iiab)gty as may be provided ln a policy of In surance which the undersigned's Insurance compa y Issue upon said object and then only In accordance with the terms of said policy.Date 19 Signed (Authohzed Inspector)

Commissions (Nadonal scald (Inc.endorsements).

state, prov>>and no.)

149AI)FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 8 Light Co.Nafrre Two North Ninth St., Allentown, PA 18101 Address Date Sheet May 8, 1995 1 of 2.Plant Susquehanna Steam Electric Station Nalrie PO Box 467, Berwick, PA 18603 Unit One DCP 934090A,B,C,&D Work Authorizations C43725, C43726 C43727 C43728 3.Work Performed by Address Penns Ivania Power&Light Co.Narrre Repair Oiparriaaboo P.O.No., Job No., eto.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentificatlon of System Residual Heat Removal S stem 149A Class II 5.(a)Applicable Construction Code III 19 71 Edition, thiu W72 Addenda, (b)Applicable Edmon of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board Other Identiilcation Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)BONNET BONNET BONNET BONNET BONNET BONNET MCC PACIFIC VALVES CONTROL COMPONENTS INC.MCC PACIFIC VALVES CONTROL COMPONENTS INC.MCC PACIFIC VALVES CONTROL COMPONENTS INC.S/N XN050 M61 8920-S/N3 S/N XN051 M61 8920-S/N2 S/N XN052 M61 892~/N1 NIA NIA N/A N/A 151F031A 151F031A 151F031B 151F031B 151F031C 151F031C 1976 1994 1976 1994 1976 1994 REPLACED REPLACEMENT REPLACED REPLACEMENT REPLACED REPLACEMENT YES YES YES YES YES YES 7.Description of Work Replace Bonnets on RHR Discharge Check Valves 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure See Remarks psl Test Temp.See Remarks F SE-1&301 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, prodded (1)size ls SN in.x 11 in., (2)lnforma tlon In items 1 through 6 on this report Is included on each sheet, and (3)each sheet is numbered and the number of sheets I recorded at the top of this form.(12/S2)This form (E00030)may be obtained from the Order Dept.~ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)g Remarks CODE DATA REPORT(S)ATTACHED Ap pticat9le hlanufacturar's Oats Repons to ba attached 151F031A-Pressure: 310.s.i./Tem erature: 68'F, 151F031B-Pressure: 265.s.i./Tem erature: 69.3'F 151F031C-Pressure: 235.s.i./Tem erature: 71.5'F, 151F031D-Pressure: 270.s.i./Tem erature: 66.3'F CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code,Section XI.REPLACEMENT conforms to the rules of the repair or replacement Type Code Symbol Stamp N/A Certilicate of Authonzatlon No.N/A Expiration Date N/A Signed ers Oeslgnae.Titte~VP&uc Operations Date 3/,tg gS CERTIFICATION OF INSERVICE INSPECTION Commissions I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof P NNSY VANIA and employed by ARKWR G A SU NC CO of WA KAM MASSAC US S have sp edthycomponentsdescribed in this Owner's Report during the period to Z 9 5 and state that to the best of my knowledge and belief, the Owner has p orm examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in a ner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

dc bl9 Inspector's Signature National Board, State, Province, and Endorsements Date 19~5 Form N-2 FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR iDENTICAL NUCLEAR PARTS AND APPURTENANCES's Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Ptuduction Pg.1of2 1.Manufactured and certttodby

~~onents etc.22591 Aceerkfs Ernprosa, Fhncho Srr/ttrr Mrr/gdr/trr.

C4 928M tcame and oddreae cr C<<Cnoaio Head<<t a.Monutecturect tor PENNSYLVAN/4 POWERS L/GHTOO.ALLEPflOWN, PA toama and<<Odreae ct puacnae<<)SVRX/EHANNA STEAM ELEIOTRC STAT)ON.5M/LES NE OF BERWJCK PA.ON RO(JTE 11 4.Typo 748800001 (dr<<who ncc)5.ASM'ode, Sec5on NI, DMaton 1 y.Remertcs PARTPORA 20 PV GHEO/r;VALVE.CO/WOR/r:ORDER r//852001/2-001 OO/DWG.R O.M P/N 748802001.

SA-105 tnacl apeo.na)1971 0.Fabrtcaied h accordance catch Const.Spec.(DN.S onty)tccrne cnd eddreaa)70.000 PS/N/A Oanete caranoo)WlVTER 1972 2 (otaaa)N/A Rovhbn PVA oas hcc)(Cede Case na)N/A tt.Nom lhkkneee (ta)8.47 Mh.design thkkness (tn.)S.dd'ta.6 (tt S h.)29length ovenul (tt S h,)NIA Q.When applkable, Certtwcato Holders'ata Reports are attachod for each ttem ot thts ropoC Na5onof Board No.h Numerkat Order part or Apurtonanco Sec(s)Ncxnber Board No.adh (1.)M8 18920-Sr%/1 (2.)M8f 8920-Qfc/2 p.)M81 8920-Sr8 (4.)M81 8920-Sr'/d (5)(0.)P)(5)(0)(10.)(11.)(t<)(1 0.)(14)(1 5.)(1 0.)(1 7.)(10.)(10)(go.)(gt)Pg)(gx)(g4)(g5.)(gg.)&)(gL)(gg)PO.)Pt)(ag)PO.)p4.)P5)PO.)P~)PO.)Ptt)(40.)(41.)(4g)(40)(44)(45.)(40)(4~)(4tt)(40.)(50.)10.Deatgn preaacxo pat.Temp.100 Deg.F ttydrateatpreeecxo N/A attemp.Deg.F scoorcm<<eat hramadm h ace tamer sara, arceknea, or dr<<whoa mer be uaed pcadded (1)ake la 4 Qsx 11.Q~h s<<sea tends cn octa Dree napat la horodad cn each aneac, (ot coen aneac la accbered and he ncaobar b ahaoce 1 receded 4 ho lop cr octa tam 1Na tam gCCOac)may be cblahad trcm he Order Dept, Asle, 22 Lew Drlre, Sac@NO, FaÃatd.Nf Otter-ZXrL Fona N-2 FORM N-2 (Back-Pg.2 of~2 Csrttrioata Holder's Serial Noa SEE PAGE 1 through AtIA R4l4V V.PAREKH PX.State PA ltag.nba 29882-E Design repat e oertned by N/A Iteg.nrL N/A wsoatyy cue tra tat<<nen4 made h hte report ae ocnsol and sue tee ttheeel ocnkams io tra nAos d ocnettuctkn d tw hSLE DxK Seotkn 5, Dtrtekn t.VALVEBONNET'CAP

%ry eartytoets d Auhattatkn Hra Bptrse JUNE7.19'1/&I~J g Nano COVTTIOLCOMPONENTS INC Stetted 1 L tea tatderatgn<<L hddhg~valid ocnvntsskn Issued by he Natknal Bead d Boter and Pr>>>>euro Vessel hap>>ster>>and tts Stae a Provhoe d CALIFORNIA and anploy>>d by HARTFORO STEAAl BOILER INSPEC77ON AIVO INSURANCE COMPANY ol HARTFORO.CONNECTTCLIT'ave twpeoted ttese tamaaectttadhhte Dec>>Report cn-1 L-4-.and atua Stat to yt beet d my on<<tedge end better.ere eettkate Hdder haa tabrtxtad hase pena a appurtataees h aaxadanos wgt ets hsL6 ctx4 8ecckn 5, D4iskn t.Each pat I>>ted has bean<<rAarlced ta atarsrhg cn he dais shown abov>>By signhg eAe oertrkate.

nether eta hapector not hk employe<makes warranty.a>>press>>ed or~trod, ocnoemhg ete actutxnent de>>orbed h ttts Data ltepaL PLrrct<<ma>>, neiher ate hepecccr nor his smptoyet chas be srb4 h arry master raary per>>anat hhayaprop<<ty damage a toss deny khd aiahg trcm a oovtectsd etta eepeotkn~.Q.fc cLr-n.~grecl Bd.(hokrdhg endor>><<neng and aura a prcN..rnd nct)ae REFER TO ATTACHED'LETTER OFEXTHVSION'ROM THEASMECARMIT7EE 149AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Name Date May 8, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet Unit 2 of One PO Box 467, Betwick, PA 18603 Address 3.Work Performed by PennSylVania POWer&Light CO.Name DCP 934090A,B,C,&D Work Authorizations C43725, C43726 C43727 C43728 Reparr Orriaaraabon p.O.No., Job rro.~etc.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentificatlon of System Residual Heat Removal S stem 149A Class II 5.(a)Applicable Construction Code III 19 7" Edition, thruW72 Addenda, (b)Applicable Edition of Section XI UtiTized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)BONNET BONNET MCC PACIFIC VALVES CONTROL COMPONENTS INC.S/N XN049 M61 892~/N4 N/A N/A 151F031D 151F031D 1976 REPLACED YES 1994 REPLACEMENT YES QNa eat shzdsW 4Xl%01l1ilh lhlf Clf55cCloh

.5248-3341 Fsr 2l240&4713 S M Amerfeen lageos gMe0hIAIClt Elghylg QS QstL7e greg~tw 704.NY>Nil 0'une 2.1994 4 Nr.Robert S.Togping1 NQI.Qh CCNTROT COMPONENTS ZNC.22591 Lvenida Eapresa Rancho Santa Margarita CA$2688 Sub)acti.Ixtenaion of Expiration Date fox AINE Certificatei of Authorization for 5 a NPT'N-1695 a N-2696)s Exp.6/7/91 a az wr.VoyyXagi This letter ia to serve aa en extension of expiration date for the subject Certificate for sthich the current expiration date ia June 7, 1994.Since the xesultI of the ASME survey conducted on April ll-13>L9I94 are presently heing evaluated hy the AS)K, this extension vill allow<<ufficient tine for the evaIuation to be cceylotad.

Aexofore, this extension vill expire upon the Cate of the ccenplotion of the evaluation of the results or on September SO<1994 vhichevez cosei firlt.Very truly yours, WWI~I~Joseph A.Ruseo Manager, hccroditation (212)605 3387 cc: 1ZA-Hartford steam IoLler/heslie Bkora State of Ck/John Leaire Chnn., SC-Nh FSle/CNPT 4 c'ta~rn mi~anuritaw<i T~AT<OO ta tabac FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner 2.Plant Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Addieaa Susquehanna Steam Electric Station Name Date Sheet Unit May 10, 1995 1 of One PO Box 467, Berwick, PA 18603 Addreaa DCP 934092A&B Work Authorizations C43721, C43752 C43722 C43753 Repair Organizaboir P.O.No., Job No., eto.3.Work Performed by Pennsylvania Power 8 Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Addreaa 4.Indentificatlon of System Authorization No.Expiration Date Core S ra S stem 151A Class II N/A N/A 5.(a)Applicable Construction Code III 19 71 Edition, thru MP72 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)BONNET BONNET MCC PACIFIC VALVES CONTROL COMPONENTS INC.S/N XN131 M618930-S/N2 NIA N/A 152F003A 152F003A 1976 REPLACED 1994 REPlACEMENT YES YES BONNET MCC PACIFIC VALVES S/N XN130 N/A 152F003C 1976 REPlACED YES BONNET BONNET BONNET CONTROL COMPONENTS INC.MCC PACIFIC VALVES CONTROL COMPONENTS INC.M61 8930-S/N1 S/N XN129 M61 89354/N3 NIA NIA N/A 152F003C 152F003B 152F003B 1976 REPLACED 1994 REPLACEMENT 1994, REPLACEMENT YES YES YES 7.Description of Work Replace Bonnets on Core Spray Discharge Check Valves 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure See Remarks psi Test Temp.See Remarks F SE-151 301 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8N in.x 11 in., (2)informa tlon ln items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets I recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)9.Remarks CODE DATA REPORT(S)ATTACHED Applicable Manufacbrrera Data Repcrta tc be artachert 152F003A&C

-Pressure: 290.s.i./Tem erature: 96.8 F 152F003B&D

-Pressure: 299.s.i./Tem erature: 67.6'F CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.repairer replaCement Type Code Symbol Stamp N/A Certificate of AuthorizaUon No.N/A ExpiraUon Date N/A Signed er r er'a Deaipnee, Titl V p+uc Operations Date ,19 CERTIFICATION OF INSERVICE INSPECTION Inspector's Sfgnature I, the undersigned, ho!ding a valid commission issued by the NaUonal Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof SY V NIA and employed by AR GHT MUTUA SURANC CO of WA A MASSAC US S have.fnspect the components described in this Owner's Report during the period to ZC>W and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examfnations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor hfs employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

~el National Board, State, Provfnce, and Endorsements Date 19~&

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner P';Plant Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Date Sheet Unit May 10, 1995 2 of One PO Box 467, Berwick, PA 18603 Address DCP 93-3092A&B Work Authorizations C43721, C43752 C43722 C43753 Repair Orgaoizabon P.O.No., Job No.~eto.3.work Performed by Penns Ivania Power&Light Co.Name Two North Ninth St., Allentown, PA=18101 Address Type Code Symbol Stamp Authorization No.None N/A 4.Indentillcatlon of System Core S ra S 5.(a)Applicable Construction Code III 19 71 EdiUon, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6.Identification of Components Repaired or Replaced and Replacement Components Expiration Date stem 151A Class II thru W72 Addenda, N/A 89 N/A Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or.No)BONNET BONNET MCC PACIFIC VALVES CONTROL COMPONENTS INC.S/N XN132 M618930-S/N4 N/A N/A 152F003D 152F003D 1976 1994 REPLACED REPLACEMENT YES YES tefaa aaf Cszfggg~~mAhf'on ind CIrNcetan'52454S1 Fst 21240647'l3 S The Amirfcin 5pgsty oT MOChlhlCI t Blglniirg 345 East47e Rntl New Yorker.NY'l00ll Nunc i, l994 Nr.Robert S.Tnppine>Igr.QA COHTROZ.COMPONENTS XNC e 22591@venido Eapresa Rancho Santa Margarita, CA 02688 Sub)eat:.Extension of Expiration Date for hSME CertifLcates of Authorization fox 5 l NPT (5-2695 a N-2696)s Exp.6/7/04 Doer Mz.'oypinyi This letter Ls to serve as an extension of expiration date for the subject, Certificate for which the current"exyiracion date is June 7, 1994.Since the results ef the LBME survey conducted-on April 11-)3<)994 ero presently hei'valuated hy the aSNE, this extension vi)1 allov sufficient togae for the evaluation to be cceylated.

Therefore, this extension will expire upon the date of tho cceplotkon oX the evaluation of the results or on Beytembor 80f.l994 whichever cories first.Very truly yours,~so~~~ggygggggggVWO~O

~h~'4~~~IO~~C Joseph L.suseo Manager, Accreditation (2)2)605 3387 JAR/mn cc: Ale-Hartford Steam Bojler/heIXie Slcora State of Ch/John Leaire Ckhtl (SC-N F5.le/CAPT 5'V O'OB6C COB LTL~SlbHNOdK03 10%803'T:OT-'6-6-9-AG LlGS Form N-2 FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES>>

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg.1 of2 1.Manlrscrtxed and cercrwd by ccnfroI ccrrrpcsispnrs Iitc.22591 Awn'cfd Emprcssa, RdrtcIsosrrnfrr Margrrrrfd, cA 92688 twme and eddceee ct Cecrnssle Hctded 2.Mancdacaxed for PENNSYLVANIA POWERS LIGHTCO..ALLEWUWN.PA hams snd address cf sctwsed 3.Locadon of lnstaffsdon S(JSO(JEHANNA S7EAM ELECTRCSTAT)ON 5MILESNE OFBERWICK PRON RO(JTE 11 4.Type 748800001 (drescho net)L ASM'ode, Secdon N, Dtstefon 1 r.R nwrtcs PARTFORA r2 PV CHECKVALVE CCI WORKORDER rF652001/2-008 CCI DWG.8, O.hI.P/N 74880100I.

SA-105 tmstl apex ncs)1971 (edttcn)0.Fabrfcated tn accordance with Const Spec.(Olv.2 only)hema and address)70000PSI N/A (ssnele atrsntrO)fctt10 WINTER f972 2 r (addenda dste)rstase)hYA llevwon IIVA oa>>tscs)(Cede Csee ncs)N/A tL Norrt thtctcness (lit)247 Mfa desfgn thfctclwss oit)2.44'fs.0 (ft tL lL)229 Len0th overall (tt tL fiL)NIA 0.When applicable, Cerdtftcate Holders'ata Reports are attactwd for each Item of thfs repoC Natfonsf Bcwd No.In Numertcsd Order part or Apcrrtenance Serial Ncxnber Natfonaf Bcwcf No.ln Ncxlleftcsf Order It(6f8980>>

9/N I (2.)M6f89SO Sr%2 (3.)M618980 St(VS (4.)N618980-SW4 (5)(fL)P)(0)(0)(10)(1 1.)(12.)(13.)(14)(1 5.)(1 tL)(17.)(1 fL)(10.1 (20)(21.)(22)(23)(24)(25)NA NA N/A N/A (2cL)(2y.)(2L)(21L)(30.)Pl.)P2)P3.)P4)p5.)PtL)py)(3L)P0)(40.)(41.)(42)(43.)(44.)(45.)(4cL)(47)(4tt)(4tL)(M.)1tL Oeet0n presstxe 275 p*Temp.11Xf Oct).F Hydrcx isa presecxe h(rA at temp.Oct).F 0'scpplsmencet hrcnnadcn h sw teem cl esse.skcesclwe, cs drssehos mey be essed prided (1)etre ls s tR x 1t.tt)ldcnnd ten h lans 2 end 3 cn acts Data ftepcrt ls hcascsed cn cess srweL Q eesn srwet Is succored snd sw nun4>>to erwets ls reoccded st sw lcp cf ests tenn.1Ns tenn gCXOSC)mey be cbtehed harn ew Order Dept, Astor.Rt Less Dcassc Bcsc3XO, Fetrtleld, ttf Crccy-tcCCL Form N-2 FORM N-2 g3ack-Pg.2 af~2 Certnoss Holder's Sertet Hos.SEEPAGE1 tvougn ILIA R4JAN V.PARCH pz.State PA tlag.ncc 25892-E p~state N/A ltd.raa N/A Ws oarlty tut t>>catamants made h tda report<<e os<<act and eat tea tt>>ae7 orntame to t>>tutee d ocnatructkn ct t>>AS'ede Sactkn N.DMakn k VALVEBCNNET CAP tPT C<<tncate d Au>>rttatkn Na 2856 ae AAVE7.15t5td oa~w CG1lvRtL CCNFNsrra rrc.~C<<trbate Hctdag L t>>uzi<<attytecL hddhg s vstkt ocnsrdaekn issued by t>>ttatknet Bo<<d d Boter and pressure Yaeeet hapaoton and he State cr prtarhoe ct CALIFORNIA anct employed by HARTFQRO87E4M SQILERINBPECTTCNAND IVSURANCECQMPANY ot HARTFQRO CQNNECl7CUT h<<re hapsoted t>>ae a<<ne deecrbedhhta Date ttapcrt cn-/i'.and atate tMt to t>>beat ct my knoatadge and bettat, t>>Cantbate Herder has tabrbated t>>ee pens cr appurtan<<a>>s h accord<<>>e erat t>>ASIA Code Saolkn%.DMakn t.Each p<<t tered has been<<rhcrtted lor atamphg cn t>>date ahaan abrase By algnhg hta o<<tttoate.

nettw t>>hapector rw his empkyar makes arBraray, espraeaeed a trptl<<L ocnoemhg t>>equhmant daeorbed h hta Date ttapcrc Furtwnwn nohow t>>hapeotcr ncr hie employer shat be table h any m<<e'er loran'erscnat

~orprto<<ty damage cr kae or any khd ariahg trcm cr oonecaed arch)hie hapsolkn.~~m-xc ON sr~a~~.~@~i~porn~~/4cjrr I gtatl BrL Ihctudhg andora<<nano and state cr prov and no)"REFER lUAlTACHEO'LETTEROFEXTHVSCA RKW 771EASrIECCIlIIrfl77EE.

162B Il FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Ovmer Pennsylvania Power&Light Co.Name Date May 30, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Sheet 1 of Unit One PO Box 467, Berwick, PA 18603 Address PMR 934077, WA C43767 Repair Oriiaeiaadon P.O.No..Job No., eto.3.Work Performed by Pennsylvania Power&Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Authonzatlon No.N/A Expiration Date N/A 4.Indentification of System HIGH PRESSURE COOLANT INJECTION HPCI SYSTEM 152B CLASS II 5.(a)Applicable Construction Code III 19 7" Edition, (b)Applicable Edition of Section XI Utilized for Repairs or Rephcements 19 89 6.Identification of Components Repaired or Rephced and Rephcement Components Addenda, Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board Other Identlficathn Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)VALVE DISC ANCHOR DARLING S/N 2 HT¹4353 NA HV-155F001 1975 REPLACED YES VALVE DISC ANCHOR DARLING U6849 NA HV-155F001 REPLACEMENT YES 7.Description of Work INSTALL NEW DISC IN VALVE HV-155F001 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure 1160 psl Test Temp.80'F NOTE: 'upplemental sheets In form of lists, sketches, or drawings may be used, provided (1)size Is 8rra ln.x 11 in.~(2)Informa tion in items 1 through 6 on this report h included on each sheet, and (3)each sheet is numbered and the number of sheets I recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)g Remarks CODE DATA REPORT(S)ATI ACHED Appticabld Mahtrfachrrera oata Reperta td be attached CERTIFICATION OF COMPLIANCE We certify that the statements made ln the report are correct and this ASME Code,Section XI.REPLACEMENT conforms to the rules of the repair dr rdptacdrheht Type Code Symbol Stamp N/A Certificate of Authorization No.N/A Expiration Date N/A Signed dr dl'a oealtrhee, Titte vp+ttc operatlohs Date , re~5" CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof PE NSYL I and employed by A IGHT MUTUAL INSURANCE CO of WA AM SSAC US S ha e ins ted the components described in this Ovmer's Report during the period to S and state that to the best of my knowledge and belief, the Ovmer has performed examinations and taken corrective measures described In this Owner's Report ln accordance with the requirements of the ASME Code,Section XI.By signing this certilicate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any Idnd arising from or connected with this inspection.

Date Inspector's Signature re~&Commissions FW Mb/9 AHI National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner 2.Plant Pennsylvania Power 8 Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Date Sheet Unit May 4, 1995 1 of One PO Box 467, Befwick, PA 18603 DCP 89-9153B, WA's C33301, C33303, C33304 3.Work Performed by Address Penns Ivania Power 8 Light Co.Name Repair Organiaatierr P.O.Na, Job Nra, etc.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Authorization No.N/A Expiration Date N/A 4.Indentification of System EMERGENCY SERVICE WATER SYSTEM 154A CLASS III 5.(a)Applicable Construction Code I I I 19 71 Edition, thru W72 (b)Applicable EdiUon of Section XI Utilized for Repairs or Replacements 19 80 thru tAf80 6.Identification of Components Repaired or Replaced and Replacement Components r Addenda, Code Case and IWF-7000 W 1982 Addenda Name of Component Name of Manufacturer Manufacturer Serial No.National Board Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT BECHTEL NIA N/A SP-HBC-139-H3 1982 REPAIRED NO PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT BECHTEL PP+L BECHTEL PP+L BECHTEL NIA NIA N/A NIA NIA N/A N/A N/A NIA N/A SP-HBC-131-H11 SP-HBC-131-H11 SP-HBC-139-H2050 SP-HBC-139-H2050 SP-HBC-139-H2051 1982 1982 1982 REPLACED REPLACEMENT REPLACED REPLACEMENT REPLACED NO NO NO NO NO 7.Description of Work Removal, reinstallation and modification of existing pi e su orts.8.Tests Conducted:

Hydrostatic Pneumatic Other Pressure Nominal Operating Pressure NONE REQUIRED'F NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1)size is 8A in.x 11 In., (2)informa tlon ln items 1 through 6 on this report is Included on each sheet, and (3)each sheet is numbered and the number of sheets I recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.1001 7 FORM NIS-2 (Back)This NIS-2 is being submitted to report pipe support work that should have been included in an Applicable Manufacturers Oats Reports to be attached NIS-2 for s stem 154A-III reviousl submitted with the Unit 1 Seventh Outa e Summa Re ort.CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code,Section XI.REPLACEMENT conforms to the rules of the repa1r or replacement Type Code Symbol Stamp'ertilicate of Authorization No.Signed P N/A N/A Expiration Date Date N/A , 19 Owner er s Oesipnee, T1tte Vp&uc Operations CERTIFICATION OF INSERVICE INSPECTION Inspector's Signature~g~Date I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State orProvinceof PE NS LVANI and employed by AR IG UTUAL INSU CE CO.of A M SS C USETTS have inspected the components described in this Ovmer's Report during the period-2 4 to/>>, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures d~h~lpthis Owner's Report in accordance with the requirements of the ASME Code,Section XI.g-8>-vs By signing this certilicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ovmer's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any Idnd arising from or connected with this-ins paction.Commissions M f 8 5/National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 8 Light Co.Date May 4, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet 2 of One 3.Work Performed by Pennsylvania Power 8 Light Co.Name PO Box 467, Betwick, PA 18603 Address DCP 89-9153B, WA's C33301, C33303, C33304 Repair Organization P.O.Na.Job Na.eto.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentificatlon of System EMERGENCY SERVICE WATER SYSTEM 154A CLASS III 5.(a)Applicable Construction Code II I 19 71 Edition, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 thru NP80 6.Identification of Components Repaired or Replaced and Replacement Components Addenda, Code Case and IWF-7000 W 1982 Addenda Name of Component Name of Manufacturer Manufacturer Serial No.National Board Other Identiilcatton Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PP+L BECHTEL PP+L BEG HTEL PP+L NIA NIA NIA N/A NIA NIA NIA NIA NIA SP-HBC-139-H2051 SP-HBC-139-H2001 SP-HBC-139-H2001 SP-HBC-140-Ht SP-HBC-140-H1 1994 REPLACEMENT 1982 REPLACED 1994 REPLACEMENT 1982 REPLACED 1994 REPLACEMENT NO NO NO NO PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT PIPE SUPPORT BECHTEL PP+L BECHTEL PP+L BECHTEL PP+L NIA N/A NIA NIA N/A N/A N/A N/A N/A N/A NIA N/A SP-HBC-140-H2017 SP-HBC-140-H2017 SP-HBC-1 40-H2021 SP-HBC-140-H2021 SP-HRC-126-H2005 SP-HRC-126-H2005 1982 REPLACED 1994 REPLACEMENT 1982 REPLACED 1994 REPLACEMENT 1982 REPLACED 1994 REPLACEMENT NO NO NO FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Ovmer Pennsylvania Power&Light Co.Date May 4, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Sheet 3 of Unit One PO Box 467, Berwick, PA 18603 Address DCP 89-9153B, WA's C33301, C33303, C33304 Repair Organraairen P.O.Na, Job Na, etc.3.Work Performed by Penns lvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Type Code Symbol Stamp Authorization No.Expiration Date None N/A N/A 4.Indentificatlon of System EMERGENCY SERVICE WATER SYSTEM 154A CLASS III 5.(a)Applicable Construction Code III 19 71 Editkn, thni W72 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 thru Mr80 6.Identification of Components Repaired or Replaced and Replacement Components Addenda, Code Case and IWF-7000 W 1982 Addenda Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year BUIII Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT 8ECHTEL NIA N/A SP-HRC-127-H5 1982 REPLACED'O PIPE SUPPORT PP+L N/A N/A SP-HRC-127-H5 1994 REPLACEMENT PIPE SUPPORT PIPE SUPPORT BECHTEL PP+L NIA N/A NIA SP-HRC-130.H5 1982 SP-HRC-130-H5 1994 REPLACED REPLACEMENT NO

\'OAM N4 lttT CXRIIFICATX HOLDRR5'TA RItOh'.T FOR NUCLEAR tART Alfie As requited by the Pttt Ylsloa QC the Ash(S Code Rtales.Sccdoa ill.D(Y.I o\'r".Anchor/Darlfn Valve Coot 701 Ffrst Stoa Nllfamsport, PA 17701 laced aea~KÃpf acaacea~aaeaeca (b)ilaoafacaaaced P 5 t T r rh IaaeKe eas eeKeae ec a acsaeeae aaeaear ar eaoaeaee eecaaer weaas~5ectsl lto.cf part" ac'1 Id.lf H/A C~~~co~5 lfae 013570 Drsarha5 prepared by'nchor/Darl fn Valve~+-.'4 (g~ipc of p<<c la,~'ISC HEAT SS6141~SA216-NCB lcl araacell reCECocoeecroelU,~~~, CrkmJakNe&tt, Core No.Cl~.".10a-900$F.M.GATE g~hl, (aaaec eeeensaaea ec eeeeaee cee aaaaea eeoc~a oee eeeaeaaeco A DY SHOP ORDER ET751-1 l~I'101 Co any NOTE: HO DISC HYDRO PERFORMED Te csccify Ihac dao sw~cs aaede aa dais repecc sce ccaceec aal dais ceasel pact oc eppocaeaeoce as defiacd ha che Code cso focms co che roles of c~eccceecioa ef dae ASttE Code Seecioa lIL tIhe apsttcahte Destsa speetttcactoaa aa4 saceas aspect are aoc the roasoasthQ!%

ef thcÃFT'crctftcaac Holder aar parts.Aaa Nry ccraf-icace ltotdsr for appectcmecsv b reaeaaaaihle for fsrakahiaag a aepaaaas Decima Spectftcadoa aad Stress a~af Ihe spyartwaos a aoc tactadcd la the compsacat DeQes 5pectttcactm aa4 5crws ttcpoct.l Dace~~Anchor/Darl fn Valve Co.zI~aasaceea Iaeaeaca AA~d E~CecUicsce of Aadaociacsc4ze Mo,~'e h ahglaarr'-~t5Q;-'yVfaaa~~>i'I Desisa iafocaaioa

<<file ec Serosa mlysis repen ea Qe ac Deslsa speeifksuoas certified by stress aaalyels tepocc ceccianaed by Nerf.Eoa.Seer acr Ne..Prof Eat.SI~aer No.CEKIIFICA'IION OF DESIGN FOR APPURTENANCE (Hea aptHeabie)

CEFlIFICATE OF SHOP 1NSPECT10N"I, p j:~I'ele l, che eadersisaaed, bola4as a relid eowiseia iseaed by Ihe Necioaal Booed of 24ilec aa4i Pres~Vessel leepeccocs of ace'teppiel che pace of a paessaae ceasel described ie ahie Parttat Data ltcsort Isa.aa4 Crate that tO the heat Cf ar kaeaatedae aad taetlef.the ftPT CCrtttlCate HOlder haa CCIIKmeted thts Part la a 5 with the ASttK Cede SCCttaa ttt, 5y sigaia5 Ibis ecccificsccr eeiaher ahe laepeecoc eor his esployer aeahes eay eacreacy, espceseed ce iotaned, coecera tag the part dcscrthed lh this parttal Data ltcport.yarthcrmorc.

aclthcr thc tntpcctor aor his crsploycr shall be liaMe ia aay easact for aay persossl iaiscy or property diego or~loss ol aay kisd acic:as taeaa oc ccaseeaed<<ich Ibis isspecaioa.

~S Pennsylvanfa 2392 aaeaaeeea aeereo Saeaer Paeeaeee care lace~seeeaeeecclea aaooece s lore e(~, aercrerc~Nce~e ecrveca ce ccrc~e rare Qal~~eereeee ccrg ae acre erNNCere Iaa~ace ce EW~I I~It)aeaereea~le Iaaae I I w carl~M ececrf cr wry~lorecoel oe ere L eccrerar QI77)Ttara aerala I5000eto)IIIEY beehaalaaed taecaaatatoraaetoeOI ASM',SC55.4tIII SI.Noae YOak.N.Y.10017 164A III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet May 12, 1995 1 of 2.Plant Susquehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Address Unit One DCP's 943023A&D;WA's C43582&C43583 Repair Oreancaoon p.o.No., Job No., ero.3.Work Performed by Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Type Code Symbol Stamp Authorization No.Expiration Date None N/A N/A 4.Indentiflcatton of System Emer enc Service WaterS stem 154A, Class III 5.(a)Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements19 89 6.identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)ESW SUPPLY'TO THE'A RHR PUMP MOTOR OIL COOUNG COIL BEG HTEL N/A N/A SPHBC1394 1982 REPLACED YES ESW SUPPLY TO THE"A" RHR PUMP MOTOR OIL COOLING COIL PP&L N/A N/A SPHBC1394 1995 REPLACEMENT NO ESW RETURN TO THE'A'HR PUMP MOTOR OIL COOLING COIL BECHTEL NIA N/A SPHBC1404 1982 REPLACED YES ESW RETURN TO THE"A" RHR PUMP MOTOR OIL COOUNG COIL PP&L N/A N/A SPHBC1~1995 REPLACEMENT NO ESW SUPPLY TO THE D RHR PUMP MOTOR OIL COOLING COIL BECHTEL NIA NIA SP H BC139-1 1982 REPLACED YES ESW SUPPLY TO THE D RHR PUMP MOTOR OIL COOLING COIL PP8L N/A N/A SPHBC139-1 1995 REPLACEMENT NO 7.Description of Work Installed new ESW Inlet and Outlet Piping to"A"&"D" RHR Pump Motor Oil Coolers 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure 0 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size ls 8N in.x 11 in., (2)informa-tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)9.Remarks Applicable htanufactuiers Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this ASME Code,Section XI.REPLACEMENT conforms to the rules of the repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.N/A Expiration Date N/A Signed er or s Oesitinee, Titie Vp+uc Operations Date ,19 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof P NNSY VA IA and employed by ARKWRIGHT MU UAL INSURANC CO of WALTHAM MASSAC USETTS have spected the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has pe ormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual Engineering Assoc.oh/Commissions Date Inspector's Signature i9~5 National Board, Sta e, Province, and Endorsements 164A III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Name Date May 12, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet Unit 2 of One PO Box 467, Betwick, PA 18603 Address DCP's 944023A&B;WA's C43582 8 C43583 Repair Orgaoiaarron P.O.No., Jorr Hra.ere.3.Work Performed by Pennsylvania Power&Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentification of System Eme enc Service Water S stem, 154A Class III 5.(a)Applicable Construction Code ASME III 19 71 Edition, thiu Vtr72 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)ESW RETURN TO THE 0 RHRPUMPMOTQR OIL COOUNG COIL 8ECHTEL N/A N/A SPHBC140-2 1982 REPLACED YES ESW RETURN TQ THE O RHRPUMPMOTQR OIL COQUNG COIL PP&L N/A N/A SPHBC'l40-2 1995 REPLACEMENT NO FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1-66B-II 1.Owner Pennsylvania Power 8 Light Co.Name Date 9 May, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet Unit 1 of One PO Box 467, Beiv/ick, PA 18603 Address DCP 934069 WAIf C43389 Rerrarr organizaben p.cr.Ne.~Jeb No., etc.3.Work Performed by Penns Ivania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Type Code Symbol Stamp Authorization No.None N/A Expiration Date N/A CONTROL ROD HYDRAULICS SYSTEM 155B CLASS II ASME 16448&Material: NF-2610 ASME Section III, 1977 Edition, thru Winter 1977 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 No Addenda 6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)CRD SDV VENT LINE SUPPORT CRD SDV VENT LINE SUPPORT CRD SDV VENT LINE SUPPORT CRD SDV VENT LINE SUPPORT CRD SDV VENT UNE SUPPORT CRD SDV VENT LINE SUPPORT BECHTEL PP&L BECHTEL PP&L NISCO PP&L NONE NONE NONE NONE NONE NONE N/A N/A N/A N/A N/A 1N61 IN61 1S46 1S46 1982 1982 1981 REPLACED YES REPLACEMENT NO REPLACED YES REPLACEMENT NO REPLACED YES REPLACEMENT NO-7.Description of Work THE ADDITION AND/OR CHANGE OF STRUCTURAL MEMBERS&CLAMPS 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure N/A psi Test Temp.N/A'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size Is 8N in.x 11 in., (2)informa-tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.(12/82)V This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)9.Remarks NONE 1tppticable Manufacturers Oats Repons to be attache9t CERTIFICATION OF COMPLIANCE We certil'y that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.repas or replacement Type Code Symbol Stamp Certificate of Authonzation No.N/A N/A Expiration Date'/A Signed er or rs Oes1ttnee, TN vp+uc operattons Date 53/,19 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of P NSY ANI and employed by A IG UTUA SU NC CO of WA THAM MASS C US S ha e ins ed the components described in this Qvmer's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Qwner's Report In accordance with the requirements of the ASME Code,Section XI.By signing this certiftcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Qwnet's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual Engineering Assoc.Date Inspector's Signature 19~4 Commissions S National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Ovmer 2.Plant Pennsylvania Power 8 Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Date Sheet Unit 9 May, 1995 2 of Two PO Box 467, Befwick, PA 18603 OCP 934069 WA¹C43389 3.Work Performed by Address Pennsylvania Power 8 Light Co.Name Reparr Orgaoizaborr p.O.No., Job No., ero.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentification of System 6.IdentNcation of Components Repaired or Replaced and Replacement Components CONTROL ROD HYDRAULICS SYSTEM 155B CLASS II ASME 16448&Material: NF-2610 ASME Section III, 1977 Edition, thru Winter 1977 Addenda (b)Applicable Edition of Section XI Utillaed for Repairs or Replacements 1989 No Addenda Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identiricatlon Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)CRD SDV VENT LINE SUPPORT NISCO NONE NIA 1S53 1981 REPLACED YES CRD SDV VENT LINE SUPPORT CRD SOV VENT LINE SUPPORT CRD SOV VENT LINE SUPPORT PP&L NISCO PP&L NONE NONE NONE N/A NIA NIA 1S53 1S58 1S58 1981 REPLACED YES 1995 REPLACEMENT NO 1995 REPLACEMENT NO CRD SDV VENT LINE SUPPORT NISCO NONE NIA 1N58 1981 REPLACED YES CRD SDV VENT LINE SUPPORT CRD SDV VENT LINE SUPPORT CRD SDV VENT LINE SUPPORT PP&L NISCO PP&L NONE NONE NONE N/A NIA N/A 1N58 1N57 1981 REPLACED YES 1995 REPLACEMENT NO 1995 REPLACEMENT NO CRD SDV VENT LINE SUPPORT NISCO NONE NIA 1S54A 1981 REPLACED YES CRD SDV VENT LINE SUPPORT PP&L NONE NIA 1854A 1995 REPLACEMENT NO FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 8 Light Co.Date May 12, 1995 Two North Ninth St., Allentown, PA 18101 Aridreaa Sheet 1 of 2.Plant Susquehanna Steam Electric Station Name PO Box 467, Befwick, PA 18603 Addreaa Unit One DCP's 93-3059A, B&C;WA's C43245, C43246, C43250 C43251 C43255 throu h C43258 Repair Orianrr arron P.O.No., Job No., eto.3.Work Performed by Pennsylvania Power 8 Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Addreaa Authorization No.Expiration Date N/A N/A 4.Indentification of System Reactor Vessel and Aux.S stem, 162A, Class I 5.(a)Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, N<"" Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPING FROM NOZZLE N-12A TO PENETRATION X-59A BECHTEL NIA N/A SPDCA137<1982 REPLACED YES PIPING FROM NOZZLE N-12A TO PENETRATION X49A PP&L N/A N/A SPDCA137<1995 REPLACEMENT NO VENT FROM XY-1 D004A TO SPDCA138-1 PP&L N/A NIA SPDCA137-5 1995 REPLACEMENT NO PIPING FROM NOZZLE N-11A TO P ENETRATION X45A BECHTEL N/A N/A SPDCA138-1 1982 REPLACED YES PIPING FROM~NOZZLE N-11A TO PENETRATION XASA PP&L N/A NIA SPDCA138-1 1995 REPLACEMENT NO 7.Description ofwork Installed new Reactor Water Level Condensing Chambers and associated Vent Piping 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure 0 Other Pressure 1100/1050 psl Test Temp.80/155'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8N in.x 11 in., (2)informa-tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)ASME Section III, 1977 Edition thru Summer 1979 Addenda (NB-3650)is applicable to Nuclear Applicable Manuiacturecs Data Repons to be attached Class 1 evaluation onlCERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.repair or reptacement Type Code Symbol Stamp N/A Certificate of Authorization No.N/A Expiration Date N/A'igned Owne r Owners Oesittnee, Titl Vpauc Operations Date ,19 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by AR RIGHT MuTuAL INSuRANCE CO.of WA THAM MASSACHUS S h ve inspecte~de components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has perform examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date Inspector's Signature Factory Mutual Engineering Assoc.Commissions A nl/I National Board, State, Province, and Endorsements 162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet May 12, 1995 2 of 2.Plant Susquehanna Steam Electric Station Name PO Box 467, BenNick, PA 18603 Address Unit One DCP's 9M059A, 8&C;WA's C43245, C43246, C43250 C43251 C43255 throu h C43258 Repair oriranraabon p.o.No..Job rro.~eto.3.Work Performed by Pennsylvania Power&Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentification of System Reactor Vessel and Aux.S stem, 162A Class I 5.(a)Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements19 89 6.Identitlcation of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPING FROM NOZZLE N-128 TO PENETRATION X498 BECHTEL N/A N/A SP DCA1 37-1 1982 REPLACED YES PIPING FROM NOZZLE N-128 TO PENETRATION X498 PP&L N/A N/A SPDCA137-1 1995 REPLACEMENT NO VENT FROM XY-1 D0048 TO SPDCA138-2 PP&L NIA N/A SPDCA137%1995 REPLACEMENT NO PIPING FROM NOZZLE N-118 TO PENETRATION X-658 BECHTEL NIA NIA SPDCA138-2 1982 REPLACED YES PIPING FROM NOZZLE N-118 TO PENETRATION X%58 PP&L NIA N/A SPDCA138-2 1995 REPLACEMENT NO REACTOR VESSEL HEAD VENT TO STEAM LINE BECHTEL NIA N/A SPDBA112-4 1982 REPLACED YES REACTOR VESSEL HEAD VENT TO STEAM LINE PP&L N/A N/A SPDBA112-4 1995 REPLACEMENT NO REACTOR VESSEL HEAD VENT TO PENETRATION X-59A BEG HTEL N/A NIA SPDCA145-2 1982 REPLACED YES REACTOR VESSEL HEAD VENT TO PENETRATION X-59A PP&L N/A N/A SPDCA145-2 1995 REPLACEMENT NO 162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 8 Light Co.Date May 12, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet Unit 3 of One PO Box 467, Berwick, PA 18603 Address OCP's 93-3059A, 8&C;WA's C43245, C43246, C43250 C43251 C43255 throu h C43258 Reparr Organraaeon p.O.No., Jorr No., eio.3.Work Performed by Pennsylvania Power 8 Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentification of System Reactor Vessel and Aux.S stem, 162A, Class I 5.(a)Applicable Construction Code ASME III 19 71 Edition, thru Vtf72 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identitlcatlon of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)REACTOR VESSEL HEAD VENT TO PENETRATION X498 BECHTEL NIA'IA SPDCA1454 1982 REPLACED YES REACTOR VESSEL HEAD VENT TO PENETRATION X%98 VENT FROM XY-14202 TO SPDBA112<VENT FROM XY-821-1 D002 TO SP DBA112<PP&L PP&L PP&L N/A N/A N/A N/A NIA N/A SPDCA1454 SPOCA1454 SPDCA145-9'995 REPLACEMENT NO 1995 REPLACEMENT NO 1995 REPLACEMENT NO PIPE SUPPORT RX BLDG INSIDE CONTAINMENT BECHTEL N/A NIA SPDCA137-H7 1982 REPLACED NO PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PP&L PP&L PP&L N/A N/A N/A N/A NIA N/A SPDCA137-H7 SPDCA137-H23.

SPDCA137-H24 1995 REPLACEMENT NO 1995 REPLACEMENT NO 1995 REPLACEMENT NO PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PP&L N/A NIA" SPDCA138-H26 1995 REPLACEMENT NO FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 162A I 1.Owner Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet May 12, 1995 4 of 2.Plant Susquehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Address Unit One OCP's 934059A, B 8 C;WA's C43245, C43246, C43250 C43251 C43255 throu h C43258 Reoad Orttanraaton P.O.NO., Jetr NO., ete.3.Work Performed by Penns Ivania Power&Light Co.Name Type Code Symbol Stamp None.Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentification of System Reactor Vessel and Aux.S stem, 162A, Class I 5.(a)Applicable Construction Code ASME III 19 71 Edition thru Vtr72 Addenda, N<11 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identilicatlon of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PIPE SUPPORT RX BLDG ORYWELL PIPE SUPPORT RX BLDG DRYWELL PIPE SUPPORT RX BLDG DRYWELL PP&L PP&L BECHTEL PP&L PP&L N/A NIA N/A N/A N/A N/A N/A N/A N/A N/A SPDCA138-H27 SPDCA138-H28 SPDBA112-H28 SPDBA112-H28 SPOBA112-H51 1995 REPLACEMENT NO 1995 REPLACEMENT NO 1982 REPLACED 1995 REPLACEMENT NO 1995 REPLACEMENT NO PIPE SUPPORT RX BLDG ORYWELL BECHTEL NIA NIA SPDCA145-H50 1982 REPLACED PIPE SUPPORT RX BLDG ORYWELL PIPE SUPPORT RX BLDG DRYWELL PIPE SUPPORT RX BLDG DRYWELL PP&L BECHTEL PP&L NIA NIA N/A NIA N/A NIA SPDCA145-H50 SPDCA145-H52 SPOCA145-H52 1982 REPLACED NO 1995 REPLACEMENT NO 1995 REPLACEMENT NO PIPE SUPPORT RX BLDG DRYWELL BECHTEL NIA NIA SP DCA145-H53 1982 REPLACED NO PIPE SUPPORT RX BLDG DRYWELL PP&L N/A NIA SPDCA145-HS3 1995 REPLACEMENT NO 162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Name Date May 12, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet 5 of Unit One PO Box 467, Berwick, PA 18603 Address DCP's 93-3059A, B&C;WA's C43245, C43246, C43250 C43251 C43255 throu h C43258 Repair Ortrancatioir P.O.No.~Job No., etc.3.Work Performed by Pennsylvania Power&Light Co.Name Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentilication of System Reactor Vessel and Aux.S stem 162A, Class I 5.(a)Applicable Construction Code ASME III 19 71 Edition, thru Vtf72 Addenda, (b)Applicable Edition of Section XI UtiTized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT RX BLDG DRYWELL PIPE SUPPORT RX BLDG DRYWELL PP&L PP&L N/A N/A N/A N/A SP DCA1 45-H70 SPDCA145-H71 1995 REPLACEMENT NO 1995 REPLACEMENT NO 164A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Name Date May 12, 1995 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Sheet 1 of Unit One PO Box 467, Befwick, PA 18603 Address DCP's 94-9088;WA C53150 Repair Ortiaoraabon P.O.No., Job No., eto.3.Work Performed by Pennsylvania Power 8 Light Co.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentiflcation of System Recirc-Flow Control and Jet Pum Instrumentation 164A, Class I 5.(a)Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, N/A Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other ldentllicatlon Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT RX BLDG INSIDE CONTAINMENT PIPE SUPPORT RX BLDG INSIDE CONTAINMENT BECHTEL PP&L N/A NIA N/A NIA SP DCA1 51-H2008 SPDCA151-H2008 1982 REPLACED NO 1995 REPLACEMENT NO 7.Description of Work Modified support to change natural frequency of drain line to valve HV-143F031B 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure None Required Other Pressure N/A psi Test Temp.N/A'P NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8N in.x 11 in.~(2)informa-tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept.~ASME, 345 E.47th St., New York, N.Y.1001 7 FORM NIS-2 (Back)9.Remarks Applicable Manu racturef s oats Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code,Section XI.REPLACEMENT conforms to the rules of the reparr or reptacement Type Code Symbol Stamp N/A Certilicate of Authorization No.N/A Expiration Date N/A Signed er or s Oesrgnee, Trtte VP&uc operations Date ,19 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PE SYLVANIA and employed by AR RIGHT MUTUA INSURANC CO.of WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 2.to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described ln this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ovmer's Report.Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutua Engineering Assoc.Commissions

/J National Board, State, Province, and Endorsements inspector's Signature Date FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI't73AII 1.Owner 2.Plant Pennsylvania Power 8 Light Co.rrame Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Date Sheet Unit MAY 4, 1995 1 of ONE PO Box 467, Berwick, PA 18603 Address 3.Work Performed by Penns Ivania Power 8 Li ht Co.Name DCP 95-9025, WA C53262 Repair Organizadon P.O.Na, Job Na.eto.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentificatlon of, System PRIMARY CONTAINMENT ATMOSPHERE CONTROL SYSTEM 173A CLASS II 5.(a)Applicable Construction Code ASME III 19 71 Edition, W 72 Addenda, N<t" Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 EDITION 6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)PIPE SUPPORT MECHANICAL SNUBBER PIPE SUPPORT BECHTEL PACIFIC SCIENTIFIC BECHTEL N/A 13424-81 N/A NIA N/A NIA HB8-116.H1 HBB-116-H1 H BB-1 16-H2 1982 1981 1982 REPLACED REPLACED REPLACED NO PIPE SUPPORT PIPE SUPPORT BECHTEL BECHTEL N/A NIA N/A HBB-116-H4 SP-HBB-116-H2004 1982 1982 REPLACED REPlACED NO NO 7.Description of Work REMOVAL OF SUPPORTS FROM HV-15703, HV-15704 8 HV-15705 8.Tests Conducted:

Hydrostatic Pneumatic Nominal Operating Pressure NO TESTING REQUIRED'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size Is 8N in.x 11 in., (2)informa-tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.10017 FORM NIS-2 (Back)IN RESPONSE TO EDR 94-002.Applicable Msnufscturers osts Reports to be sttscned CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code,Section XI.REPLACEMENT conforms to the rules of the repslf or fe~Type Code Symbol Stamp Certilicate of Authortmtton No.N/A N/A Expiration Date N/A Signed r or Oestgnee, Ttle VP&uc Operations Date ,19 CERTIFICATION OF INSERVICE INSPECTION Inspector's Signature I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by AR IGH A NSU NCE CO.of WAL AM ASSACHUSETTS hav in lsd the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described ln this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection Factory Mutual Engineering Assoc.Commissions

/National Board, State, Province, and Endorsements Date isa&

173A)I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner 2.Plant Pennsylvania Power 8<<Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Date Sheet Unit May 30, 1995 1 of One PO Box 467, Befwick, PA 18603 Address PMR 89401 8D WA's C04388, C04389, C04390 C 04391 Repair Organraation P.O.No.~Job Na.ero.3.Work Performed by Pennsylvania Power 8 Light Co.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Authorization No.N/A Expiration Date N/A 4.Indentificatlon of System CONTAINMENT RADIATION MONITORING SYSTEM 173A CLASS II 5.(a)Applicable Construction Code III 19 71 Edition, thiu W72 Addenda, Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)SMALL PIPE ASSEMBLY PPL NA NA SPHCB158-1 1992 REPLACED NO SMALL PIPE ASSEMBLY SMALL PIPE SUPPORT SMALL PIPE SUPPORT SMALL PIPE SUPPORT SMALL PIPE SUPPORT PPL BECHTEL PPL PPL PPL NA NA NA NA NA SPHCB158-1 1994 REPLACEMENT NO SPHCB125-H7 1982 REPLACED SPHCB159-H5 1994 REPLACEMENT NO SPHCB125-H7 1994 REPLACEMENT NO SPKCB158-H5 1994 REPLACEMENT NO 7.Description of Work INSTALLATION AND TESTING OF 1" CRM PIPING 8.Tests Conducted:

Hydrostatic Pneumatic H Nominal Operating Pressure Other Pressure 67 psi Test Temp.88/90 eF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size Is 8N In.x 11 ln., (2)informa tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets I recorded at the top of this form.(12/82)This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y.1001 7 FORM NIS-2 (Back)9.Remarks Appticable Manufacturers Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.repair or repiacernent Type Code Symbol Stamp Certilicate of Authorization No.Signed N/A N/A Expiration Date Date N/A ,19 owner era Designee, Titi vt9&uc operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANI and employed by AR IG U A INSURANC CO of WA AM MASSACHUS S have'ns e components described in this Owner's Report during the period iO to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Ownet's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ovmer's Report.Furthermore, neither the Inspector nor his employer shall be liable in a armer for any personal inJury or property damage or a loss of any kind arising from or connected with this inspection.

rQ Commissions Date Inspector's Signature 19~&National Board, State, Province, and Endorsements 173A II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.,Owner Pennsylvania Power 8 Light Co Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet May 30, 1995 2 of 2.Plant 3.Work Performed by Penns Ivania Power&Light Co.Name Susquehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Address Unit ONE PMR 894018D WA's C04388, C04389, C04390 C 04391 Reparr Organizadon P.O.No.~Job No., eto.Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Address Authorization No.Expiration Date N/A N/A 4.Indentificatlon of System CONTAINMENT RADIATION MONITORING SYSTEM 173A CLASS II 5.(a)Applicable Construction Code II I 19 71 Edition, thru Vtf72 Addenda, Code Case (b)Applicable Edithn of Section XI Utilized for Repairs or Replacements 19 89 6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serhl No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY SMALL PIPE SUPPORT SMALL PIPE ASSEMBLY SMALL PIPE ASSEMBLY PPL PPL PPL PPL PPL PPL PPL PPL PPL PPL PPL NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA SPHCB159-1 SPHCB159-1 SPHCB160-1 SPHCB160-1 SPHCB161-1 SPHCB161-1 SPHCB162-1 SPHCB162-1 SPHCB162-H4 l SPHCB163-1 SPHCB163-1/

1992 REPLACED NO 1994 REPLACEMENT NO 1992 REPLACED 1994 REPLACEMENT NO 1992 REPLACED NO 1994 REPLACEMENT NO 1992 REPLACED 1994 REPLACEMENT NO REPLACED NO 1994 REPLACEMENT NO 1994 REPlACEMENT NO FORM R-1, REPORT OF WELDED X REPAIR OR Q ALTERATION as required by the provisions of the National Board Inspection Code 184 1.Work performed by 2.Owner (name)3.Location of installation Penns ivania Power and Li ht (name of repair or alteraoon organizauon)

Two North Ninth Street, Allentown, Pa.18101 (address)Penns Ivania Power and Li ht Two North Ninth Street, Allentown, Pa.18101 (address)Sus uehanna Steam Electric Station (name)P.O.Box 467, Be(wick, Pa.18603 DCP934086 WA)f C43383 (P.O.no., lob no., etc.)4.Unit identification:

1T-105A (boiler, pressure vessel)(address)Name of original manufacturer GE/HEAT TRANSFER PRODUCTS 5.Identifying nos: 264586 60425 N/A N/A 1976 (mfr's serial no.)(original Nauonal eoard no.)0urisdlcdon no.)(other)(year built)6.Description of work: Capped 4 existing 2 schedule 80 pipe nozzles and installed 4 new 2'chedule 80 (use back.separate sheoL or sKetch If necessary) pipe nozzles.Also capped 1 existing 1 schedule 80 pipe nozzle.Pressure test, if applied N/A psl 7.Rep(acement Parts.Attached are Manufacturers'Parth(Data Reports property indentirled and s)gned by Authorizedhspectors forthe fol)owing items of this report NIA 8.Remarks: NONE (name of parL item number, mfr's.name and identifying stamp)This form may be obtained from the National Board of Boiler and Pressure Vessel inspectors, 1055 Crupper AveColumbus, OH 43229 OESIGN CERTIFICATiON The undersigned ceNIIes that the statements made in this report are correct and that the design changes described in this report conform to the requirements of the National Board Inspection Code.ASME Certificate of Authorization no.to use the symbol expires 19, Oats 99 (name of organtzatlon)

Signed (authorlze4 representadve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Commision issued by the National Board of Boiler and Pressure Vessel Inspectors and certilicate of com-petency issued by the state or province of and employed by of has examined the design change as described in this report and verifies that to the best of his knowledge and belief such change complies with the applicable requirements of the National Board Inspection Code.By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or implied, concerning the work described in this report.Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal Injury, property damage or loss of any kind arising from or connected with this Inspection, except such liabNty as may be provided in a policy of in surance which the undersigned's insurance company may issue upon said object and then only in accordance with the terms of said policy.Oata 19 gtgaad (Authorized Inspector)

Commissions (National eoard (Inm.endorsements), state, provand no.)f CONSTRUCTION CERTIF(CATION The undersigned certifies that the statements made In this report are correct and that all construction and workmanship on this R A(R conform to the National Board Inspection Code.(repair or alteradon)

Cert)I)cate of Authorization no.NIA to use the NIA oats~48

>III 162A-II 164B-I 173 C-II 183 A-I 183 A-II 183D-III 183H Y40074 Y40076 Y40079 Y40158 Y40067 Y40067 Y40170 Y40265 Y40262 Y40093 Y40145 Y40260 Y40092 H40198 Y40093 Y40109 Y40097 Y40266 Y40333 Y40120 Y40304 Y40302 Y40302 Y40151 Y40153 Y40154 Y40081 Y40081 Y40224 Y40081 Y40280 GBB104H8 GBB104H47 GBB109H35 DBB109H16 EBB 102H15 EBB 102H15 DBC102H17 MST22H48 MST22H32 MST22H47 DBA102H12 MST22H17 MST22H19 MST22H24 MST22H47 SPD CA102H20 RWS100H49 RWS100H12 SPHCB122H2005 SPD CA149H2003 SPDCA149H2006 SPDCA148H2010 SPDCA148H2009 DBB102H12A DBB103H7A DBB104H13A'BC101H272 GBC101H193 GBC101H147 GBC101H272 SPDBB124H4 2 Hea Hex Nuts, 1 Load Stud 1 Hea Hex Nut Ground Rear Bracket Weld 1 Load Stud Grind 1/16" off Clam 1 Load Stud, 2 Hea Hex Nuts 1 Pivot Pin 1 Load Stud, 2 Hea Hex Nuts 1 Load Stud, 2 Hea Hex Nuts 2 Hea Hex Nuts 1 Pivot Pin 1 Load Stud, 2 Hea Hex Nuts 1Load Stud 1Hea Hex Nut 1 Pivot Pin 1 Load Stud 1 Load Stud, 1 Hea Hex Nut 1 Pivot Pin Grind 1/16" off Clam 1 Load stud, 1 Pivot Pin, 2 Hea Hex Nuts 2 Hea Hex Nuts 2 Hea Hex Nuts 1 Load Stud, 2 Hea Hex Nuts 1 Pivot Pin 1 Pivot Pin 1 Pivot Pin 1 Pivot Pin 2 Hea Hex Nuts 1 Pivot Pin, Grind 1/16" Steel From Clam 1 Pivot Pin 1 Load Stud 1 Load Stud, 1 Pivot Pin r a a o~b C SNUBBER NIS-2 FORMS FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 02@A-lll 1.Owner Pennsylvania Power 5.Light Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Sheet 1 of Unit Maintenance/WA 0 Y40085 Asew Orcwaaiion P.O.No..Joir No..eio.3.Work Performed by Owner Name Type Code Symbol Authonzation N/A N/A 4.Identificadon of System Expiration Date 024A Class III Diesel Generator B Exhaust N/A 5.(a)Applicable Construcdon Code AS ME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National ,Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Mech Shock Pacific Scientific Mech Shock Arrester Pacific Scientific 19504 19448 N/A N/A HBCSH2 HBCSH2 1981 1981 REPLACED REPLACEMENT YES YES 7.Description of Work Re laced existinsnubber with same size, functionall tested re lacement snubber.I 8.Tests Conducted: Hydrostatic Pneumatic Q Nominal Operating Pressure Q-*a op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is SYs in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(1 2/82)10017 This farm (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York.N.Y FORM NIS-2 (Back)9.Remarks N/A Aooscacse M ahNr ecru<sr'a oar~Resene re oe auacnec CERTIFICATION OF COMPLlANCE We certify that the statements made in the report are correct and this ASIVIE Code,Section XI.replacement conforms to tho rules of the Reoar er Reolaccmenc Typo Code Symbol Stamp Cerdficate of Authorizadon No.N/A N/A Expiradon Oats N/A~h Signed towner Oe/ner'Oesionee.Tice V.ia.~NUCtEAR OPGtAlloNS a I Oats<g/gI ,19 95 CERTIFICATION OF INSERYICE INSPECTION inspector's Signature I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the."--" State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.Ot WALTHAM MASSACHUSETTS have inspected tho components described,.in this Owner's Roport during the period 03/25/95 to 05/06/95 , and state that to the host of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASIYIE Code,Section XI.By signing this ceruficate noither tho Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liabio in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio.FACTORY MUTUAL ENQ ASSOC.r r Commissions 4/J.4'fll National Board, State, Province, and Endorsements Oate: AF, 19~5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 134G-ill 1.Owner n Pennsylvania Power 5 Light Co.Nunc Date 05/18/95 2.Plant Two North Ninth St., Allentown, PA 18101 Add race Sus uehanna Steam Electric Station Nunc PO Box 467, Berwick, PA 18603 Sheet 1 of Unit Maintenance/WA 0 Y40258 iieoair orqanrrauon p.o.No, Joe No..eic.3.Work Performed by Owner Name Typo Code Symbol Authorization N/A N/A Expiration Date N/A 4.(dentil(cation of System 1-34G Class III Reactor Buildin Heatin 8t Ventilation S stem 5.(a)Applicable Construction Cods ASME III 19 71 Edition, W'72 Addenda Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Reploceinonto 18'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Mech Shock Pacific Scient(((c 27958 N/A HRC123H15 1982 REPLACED NO Mech Shock Arrestor Pacific Scientific 28832 N/A HRC123H15 1982 REPLACEMENT NO 7.Description of work Re laced existinsnubber with same size, functionall tested re lacement snubber.8.Tests Conducted: Hydrostatic Q Pneumadc Q Nominal Operating Pressure Q Exempt QX Pressure psi Test Temp.oF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8)rr in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(12/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Remarks N/A Aoo4caoie Mantrlacttrrer'a Oat~Resorts to Oe attacneo CERTIFICATION OF COMPLIANCE We cerdfy that the statements made in the report are correct and this reolecament conforins to the rules of the ASME Codo, Secdon XI.iteoarr er Reolacement Type Code Symbol Stamp N/A Certificate of Authorization No.Signed N/A Expiration Onto Oats N/A ,19 95;Owner cr wner's Oesronae.litic v.ir.-Ituctartn opGvttlorts I CERTIFICATION OF INSERVICE INSPECTION I, the undersignod, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.ofWALTHAM MASSACHUSETTS have inspected the components described.. in this Owner's Report during the period 03/25/95 to 05/06/95 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of tho ASME Cods,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correcovo measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall bo liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio QFCTORY MUTUAL ENQ ASSOC.Commissions /I National Board, State, Province, and Endorseinents Inspector's Signaturo Oate: , 19~+ FORM NIS-2 OV/NER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 5.Light Co.Nome Two Nonh Ninth St., Allentown. PA 18101 Date Sheet 05/18/95 1 of 2.Plant Sus uehanna Steam Electric Station Nome PO Box 467, Berwick, PA 18603 Unit Maintenance/WA S'40269 Aepw Orcerrreerion p.O.No., Joir No., oto.3.Work Performed by Owner Type Code Symbol Authorization N/A 4.Identification of System Expiration Oats 1-45A Class I Feedwater Common Dischar e 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI UtTiized for Repairs or Replacements 19'89 No Add.6.Idenrification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name ot Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Cods Stamped (Yes or No)Mach Shock Pacific Scientific Mech Shack Arrestor Pacific Scientific 12967 06668 N/A N/A SPDBA103H2000 1981 SPDBA103H2000 1979 REPLACED No REPLACEMENT No 7.Description of Work Re laced existinsnubber with same size, functionall tested re lacement snubber.8.Tests Conducted: Hydrostatic Pneumatic P Nominal Operating Pressure Q Exempt px Pressure psi Test Temp.op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8'h in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(1 2/82)10017 This term (E00030)may be obtained from the Order Dept., ASME, 345 E.47th StNew York, N.Y FORM NIS-2 (Back)9.Remarks N/A AooaCaole M anssl acliees's 0 ala Reoerla le be all sensa CERTIFICATION OF COMPLIANCE We cerdfy that the statements made in the report are correct and this r<<c<<~e<<conforms to tho rules of the ASME Codo,Section XI.Reow er Reolaccrnenl Typo Code Symbol Stamp N/A Cerdficate of Authorization No.N/A Expiration Oate N/A Signed ow er oassner'e oeaionee.Title v.p.~NuctEAR opfRATIQNs Oats W c Z 8,19 96 CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stato or Province of PENNSYLVANIA and employed by ARKWRIGHT MiUTUAL INSURANCE CO.Of,WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the pened 03/25/98 to 05/06/95 , and state that to tho best of my know(edge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certiflCato neithor the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report.Furthermore. neither tho inspector nor his employer shall bo liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. fACTORY IsIUTUAL ENG ASSOC.Commissions 'iin t 4 p National Board, State, Province, and Endorsements Inspector's Signature Oats: sr'19~8 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI'1 49A-l l 1.Owner Pennsylvania Power&Light Co.Mama Two North Ninth St., Allentown, PA 18101 Oats 05/1 8/95 Shoot 1" of 2.Plant Sus uehanna Steam Electric Station Noma PO Box 467, Berwick, PA 18603 Unit Maintenance/WA ¹Seo Sheet 3 of 3 Raow Orsarizadon p.c.No.~Joe No., aio.3.Work Performod by Owner Name Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-49A Class II LPCI/SDC RHR N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 1 Heavy Hex Nuts Grinnsll Item¹14'(1)NIA GBB104H47 REPLACED No Item 1 Heavy Hex Nuts 1 Load Stud 1 Load Stud Grinnsll Grinnell Grinnoll Item¹14'(1)Item¹13'(1)Item¹13'(1)N/A NIA N/A GBB104H47 6BB104HB GBB104HB'(1)REPLACEMENT REPLACED'(1)REPLACEMENT NO NO No'tem 2 Heavy Hex Nuts Grinnell Item¹14'(1)GBB104HB'(1)'EPLACED NO 2 Hoavy Hex Nuts Grinnsll Item¹14'(1)N/A GBB104H8'(1)REPLACEMENT 'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. 7.Ooscription of Work Re laced arts with sufficient replacement arts and round weld on rear bracket.8.Tests Conducted: Hydrostatic Pneumatic Q-.*a Nominal Operating Pressure Q si Test Temp, of NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8Yi in.x 11 in., (2)informs tion in itoms 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at tho top of this form.(12/82)10017 This form (E00030)may bs obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Remarks N/A noooceine M eniilecniiel'e cele Reoerre ro Oe enecnen CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this<<on<<<<oreo~en'onforms to the rules of the ASIVIE Code,Section XI.~Renoir or Reotecernenc Type Code Symbol Stamp N/A Cerdficate of Authorization No.Expiration Oats N/A Signed net or wner/e Oeeionee, tice VJ'.~rluotEAR OpotATIONS Oats ,19 95 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vossel inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUSETTS have inspected tho components described in this Owner's Report during the period 03/25/95 to 05/06/95 , and state that to the boat of my knowledgo and belief, tho Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with tho requirements of tha ASME Coda,Section XI.By signing this cerdficate neither the Inspector nor his employer makes any warranty.expressed or implied, concerning the examinadons snd correctivo measures described in this Owner's Report.Funhermoro, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection CTOAY MUTUAL ENQ ASSOC.Commissions 6 8~all AAJ (l National Board, State, Province, and Endorsernents Inspector's Signature Oato: F, 19~5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI'I 49A-II 1.Owner Pennsylvania Power 5 Light Co.Nome Date 05/18/95 2.Plant Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station PO Box 467, Berwick.PA 18603 Address Sheet 2 of Unit Maintenance/WA 0 See Sheet 3 of 3 Repair Oraorsoorion p.c.No., Jorr No., eis.3.Work Performed by 4.Identification of System Address Owner Nome Type Code Symbol Authorization Expiration Date 1-49A Class II LPCI/SDC RHR N/A N/A N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, Wr72 Addenda N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.e.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yas or No)Xtem.4 Item 5 Grind Rear Bracket Mech Shock Arrestor Grinnell Pacific Scientific Item 4 5'(1)28801 N/A N/A G88109H35 REPAIR SPGBB115H2008 1982-REPLACED NO NO Item 6 Mach Shock Arrestor Pacific Scientific 22875 N/A SPGBB115H2008 1981 REPLACEMENT No Item 7 Mech Shock Arrester Pacific Scientific 00552 N/A G88104HS 1978.REPLACED NO Item 8 Mech Shock Arrestor Pacific Scientific 02430 NIA G88104HS 1991 REPLACEMENT No'NOTE(1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 149A-t t 1.Owner Pennsylvania Power&Light Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Sus uehanna Steam Electric Station N eroe PO Box 467, Berwick, PA 18603 Sheet 3 of Unit Maintenance rieoer orceoLr euon p.o.rro..Joe rro..~ic.3.Work Performed by Owner Nome Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Oats 1-49A Class II LPCI/SDC RHR N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Item (s)'usquehanna Work Authorization Number Code Repair Form No.Y40076 Y40074 I95-149%07 I95-1 49-001 Y40074 I95-149-001 Y40079 Y40315 Y40315)95-149-065 I95-149<21 l95-1 49-021 Y40074 195-149-002 Y40074 l95-149-002 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1 BOA-II 1.Owner Pennsylvania Power&Light Co.Name Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Sheet 1 of Unit Maintenance/WA 4 Y40103 ireoarr Orrraniaarion P.O.No., Joe No., eic.3.Work Performed by 4.IdentiTication of System Address Owner N arne Type Code Symbol Authorization Expiration Date 1-50A Class II RCIC Pum DSCH N/A N/A N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Mech Shock Pacilic Scientific 23566 N/A SPDBB121H2012 1981 REPLACED Mech Shock Arrester Pacific Scientific 21148 NIA SPDBB121H2012 1981 REPLACEMENT No 7.Description of work Replaced existinsnubber with same size.functionall tested re lacement snubber.8.Tests Conducted: Hydrostatic Pneumatic Q-*a Nominal operadng Pressure P si Test Temp.op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8)ia in.x 11 in..(2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(12/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Remarks N/A Aooeceol~Mererre<<ttrrer'e cele A<<Cene to oe ette<<neo CERTIFICATION OF COMPLIANCE We certify that the statements made in the report aro correct and this recto<<Nlleot confortns to the rules of the ASIVIE Code, Socdon XI.Aeoelr cr Reoleceltteflt Type Code Symbol Stamp N/A Cerdficate of Authorization No.N/A Signed/ovmer or owrter'e oeercrtee. Tick v.p.-NUcLEAR opGtATtoNS 'l Expiradon Date Oate N/A ,19 95 CERTIFICATION OF INSERVICE INSPECTION National Board, State, Province, and Endorsements I , the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT NIUTUAL INSVRANCE CO.of WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 03/25/95 to 05/05/95 , and state that to the bast of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASiVIE Code,Section XI.By signing this certificate neither tho Inspector nor his employer makes any warranty, exprossed or implied, concerning the examinations and corrocuvo moasures described in this Owner's Report.Funhermore, neither the Inspector nor his employor shall bo liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. FACTORY MIJTVAL ENQ ASSOC.Comtnissions Inspector's Signature Date: 4, 19~~ FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1 62A-tt l.Owner Pennsylvania Power 5.Light Co.Nome Two North Ninth St., Allentown, PA 18101 Date Sheet 05/1 8/95 1 of 2.Plant Sus uehanna Steam Electric Station Unit PO Box 467, Berwick, PA 18603 Addreee Maintenance/WA ¹See Sheet 3 of 3 Reoar Oreerer coon P.O.No., Joe No.~ero 3.Work Performed by Owner Nome Type Cods Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-52A Class II HPCI Pum Dischar e N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Appiicabls Edition of Section XI Utilized for Repairs or Replacements ta'89 No Add.B.Identification of Components Repaired or Replaced and Replacement Components Code Case Nome of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year'uilt Repaired, Replaced, or Replacement ASME Cods Stamped (Yes or No)Item 1 1 Load Stud Grinnell Item¹13'(1)iN/A EBB102H15 REPLACED NO Item 2 Item 3 1 Load Stud 2 Heavy Hex Nuts 2 Heavy Hex Nuts Grind Clamp Grinnell Grinnell Grinnell Grinneil Item¹13'(1)item¹14'(1)item¹14'(1)Item¹12'(1)N/A N/A N/A N/A EBB102H15 EBB102H15 EBB102H1 5 EBB102H15'(1)REPLACEMENT REPLACED'(1)REPLACEMENT REPAIR NO NO NO NO'NOTE (1): SERIAL/HEAT NUMBER AND YEAR Bull.T NOT AVAILABLE. 7.Description of Work Re laced arts with sufficient re Replaced parts w3.~u x,m,en 8.Tests Conducted: Hydrostatic ~Pneumatic-4 lacement arts and round 1/16" of steel from clam.l.pa.s an clroun e Nominal Operating Pressure from c1amp.si Test Temp.op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 85 in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at ths top of this form.(12/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., Nsw York, N.Y FORM NIS-2 (8ack)9.Remarks N/A Aooliceol~Ment<<ecttiler $Octo Reoorte to Oe ettecned CERTIFICATION OF COMPLIANCE We cerdfy that the statements made in the report are correct and this reo"<<reotec<<tent conforms to the rules of the ASME Code, Secdon XI.Reow or Reotecement Type Code Symbol Stamp N/A Signed Certificate of Authorization No.N/A~1 Owner oijow'e Oeeittnee, Tide V.P.NUCLEAR OPGtATlONs Expiration Oats Oate Z~N/A ,19 95 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stats or Province of PENNSYLVANIA and employedby ARKWRIGHTMUTUAL INSURANCE CO.of.WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 03/25/95 to 05/06/95~and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ACTOAY MUTUAL KNQ ASSOC.Commissions Itr g/rP~+r4'l Inspector's Signature Nauonal Board, State, Province, and Endorsements Oats; FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 52A-ll 1: Owner Pennsylvania Power&Light Co.Name Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 2 of 2.Plant Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Address Unit Maintenance/WA 4 See Sheet 3 of 3 Raearr Oreariaaeen P.O.NO., Jeir NO..eie, 3.Work Performed by 4.Identification of System Address Owner Name Type Code Symbol Authorization Expiration Date 1-52A Class II HPCI Pum Dischar e N/A N/A N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Naine of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 4 Mech Shock Arrestor Pacific Scientific 2965 N/A DBB120H25 1978 REPLACED YES Mech Shock Arrestor Pacific Scientific 9459 NIA'BB120H25 1982 REPLACEMENT No'NOTE(1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 5 Light Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Addceee Sus uehanna Steam Electric Station Nome PO Box 467, Berwick, PA 18603 Sheet 3 Unit Maintenance of aeooo oioeoL'radon p.o.No..Joe No eto.3.Work Performed by 4.Idendfication of System Addheee Owner Nome Type Code Symbol Authorization Expiration Date 1-52A Class II HPCI Pum Dischar e N/A N/A N/A 5, (ai Appiicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Aeplecemente 19'89 No Add.6.Idendf(cation of Components Repaired or Replaced and Replacement Components Code Case Item (sl Susquehanna Work Authorizatlon Nunnber Code Repair Form No.Y40067 I-95-152-005 Y40067 (-95-152.005 Y40067 Y401 66 1-95-152436 I-95-152-054 FORM NlS-2 OV/NER'S REPORT FOR REPAlRS OR REPLAC'EMENTS As Re uired b the Provisions of the ASME Code Section XI l.Owner 2.Plant Pennsylvania Power 5.Light Co.Name Two North Ninth St..Allentown, PA 18101 Addr cad Sus uehanna Steam Electric Station PO Box 467.Berwick, PA 18603 Add(ace Date 05/1 8/95 Sheet 1 OF Unit Maintenance/WA ¹See Sheet 5 of 6 itacer Oreaazaeon P.O.No., Job No., eic.3.Work Performed by Owner Name Type Code Syinbol Authorization N/A N/A 4.Identification of System Expiration Date 1-62A Class I Reactor Head (tt Auxilia S stems N/A 5.(a)Applicable Construction Codo ASME lll 19 71 Edition, Wa72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'&9 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)t tern 1 Pivot Pin Grinnell Item¹6'(1)M/A DBA102H12 REPLACED NO I tern 1 Pivot Pin 1 Load Stud 1 Load Stud Grinnell Grinnell Grinnell Item¹6'(1)Item¹13 (1)Item¹13'(1)NIA M/A NIA DBA102H12 MST22H17 MST22H17 REPLACEMENT REPLACED REPLACEMENT NO NO NO Item 2 Heavy Hex Nuts Grinnell Item¹14'(1)NIA MST22H17 REPLACED No 2 Heavy Hex Nuts 6rinnell Item¹14'(1)M/A MST22H17 REPLACEMENT NO'NOTE (1)t SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. 7.Description ot Work Replaced exis axing s 8.Tests Conducted: Hydrostatic Exempt Qx Replaced arts with sufficient re lacement arts.er w3.same s3.ze, u Pneumatic.Q, Nominal Operating Pressure Pressure psi Test Temp.OF snubber.NOTE: Supplemental sheets in farm at lists, sketches, or drawings may be used, provided (1)size is&Ya in.x 1 1 in., (2)intorms tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.,(1 2/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Remarks N/A Aesacatse Marsrractteer'sos\a Asserts te ce anacned CERTIFICATION OF COMPLIANCE We certify that the statements made in the report aro correct and this restecerneht conforms to tho rules of the ASIVIE Codo,Section XI.Aettatr er Aecracerhent Type Code Symbol Stamp N/A Certificate of Authorization No.N/A Expiradon Oats N/A Signed Owner er canner's Oesicnee.Tide V.P.~NUClEAR OPGlATTONS Date~~~QP, 19 95 CERTIFICATION OF INSERVICE INSPECTION Inspoctor's Signature I, the undorsigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUSETTS have inspected the components described in this Ownor's Report during the period 03/25/95 to 05/06/95 and state that to the best of my knowledge and belief, the Owner has porformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither tho Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall ba liablo in any manner for any personal injury or proporty damage or a loss of any kind arising from or connected with this inspecdon FACTORY MUTUAL ENa ASSaC.Commissions 8 86 f/J j5 ArL///National Board, State, Province, and Endorsernents Oatel FORlVI NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1 62A-I 1.Owner Pennsylvania Power&Li ht Co.Date 05/1 8/95 2.Piant Two North Ninth St..Allentown. PA 18101 Addteee Sus uehanna Steam Eiectric Station rteme PO Box 467, Berwick, PA 18603 Sheet 2 OF Unit Maintonance/WA ¹See Sheet 5 of 6 Aeoev otgettttetion p.c.rtoJoe No., etc.3.Work Performed by Addkeee Owner Nome Type Code Symbol Authorization Expiration Date N/A N/A N/A 4.Identification of System 1-62A Class I Reactor Head 5 Auxilia S stems 5.(a)Applicable Construction Code ASME III 19 71 Edidon, W'72 Addenda (b)Applicable Edition of Soction XI Utilized for Repairs or Replacements 19'89 No Add.6.Identiftcat(on of Components Repaired or Replaced and Replacoment Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 4 1 Load Stud Grinnell Item¹13 (1)N/A MST22H19 REPLACED 1 Load Stud Grinnell Item¹13'(1)N/A MST22H19 REPLACEMENT No Item 5 1HeavyHexNut Grinnell Item¹14'(1)N/A MST22H19 REPLACED No 1 Heavy Hex Nut Grinnell Item¹14'(1)NIA MST22H19 REPLACEMENT No Item 6 1Pivot Pin Grinnell Item¹6'(1)N/A MST22H24 REPLACED No 1 Pivot Pin Grinnell Item¹6'(1)N/A MST22H24 REPLACEMENT No 1 Load Stud Grinnell Item¹13'(1)N/A MST22H32 REPLACED No 1 Load Stud Item 8 2 Heavy Hex Nuts 2 Heavy Hex Nuts Grinnell Grinnell Grinnell Item¹13'(1)Item¹14'(1)Item¹14'(1)NIA NIA NIA MST22H32 MST22H32 MST22H32 REPLACEMENT REPLACED REPLACEMENT No No No'NOTE(l): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Date 05/'I 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Addraaa Sus uehanna Steam Electric Station Name PO Sox 467, Serwick, PA 18603 Addraaa Sheet 3 OF Unit Maintenance/WA ¹See Sheet 5 of S Reoar orcaniaauon p.o.No., Jou rro., atc.3.Work Performed by Owner ri arne Type Code Symbol Authorization N/A N/A 4.Identificadon of System Expiration Date 1-62A Class I Reactor Head&Auxilia S stems N/A 5.(s)Applicable Construcdon Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilited for Repairs or Rerrlecements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 9 1 Load Stud 6rinneil Item¹13'(1)NIA MST22H47 REPLACED NO Item 10 1 Load Stud 2 Heavy Hex Nuts Grinnell 6rinnell Item¹13'(1)Item¹14'(1)N/A NIA MST22H47 MST22H47'(1)REPLACEMENT REPLACED NO Item 11 Item 12 2 Heavy Hex Nuts 1 Load Stud 1 Load Stud 2 Heavy Hex Nuts Grinnell 6rinnell Grinnell Grinnell Item¹14'(1)Item¹13 (1)Item¹13 (1)Item¹14'(1)N/A NIA N/A NIA MST22H47 MST22H48 MST22H48 MST22H48'(1)REPLACEMENT r REPLACED (1)REPLACEMENT REPLACED NO NO NO 2 Heavy Hex Nuts Grinnell Item¹14'(1)NIA MST22H48'(1)REPLACEMENT NO'NOTE<1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power&Light Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Addheee Sus uehanna Steam Electric Station Name Sheet Unit 4 op PO Box 467, Berwick, PA 18603 Maintenance/WA 4 See Sheet 6 of 6 rico ar Ore area aooh P.O.No., J air No..etc.3.Work Performed by Owner Type Code Symbol N/A 4.Identification of System Ad draco Authorization Expiration Date 1-62A Class I Reactor Head&Auxiliar S stems N/A N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Roplocomoh'ts 19'89 No Add.6.Identification af Components Repaired or Replaced and Replacement Components 1 Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped IYes or No)Item 13 Mech Shock Arrestor Pacific Scientific 9525 N/A MST22H42B 1982 REPLACED No Item 14 Mech Shock Arrestor Pacific Scientific 10723 N/A MST22H42B 1983 REPLACEMENT No Item 15 Mech Shock Arrestor Pacific Scientific 4091 N/A MST22H47 1979 REPLACED NO Item 16 Mech Shock Arrestor Pacific Scientific 6940 N/A MST22H47 1980 REPLACEMENT No'NOTEI1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re ljired b the Provisions of the ASME Code Section XI't 62A-I 1.Owner 2.Plant Pennsylvania Power&Light Co.Norrro Two North Ninth St., Allentown. PA 18101 Sus uehanna Steam Electric Station N orrro PO Box 467, Berwick, PA 18603 Addrooo Oats 05/1 8/95 Sheet 5 OF Unit Maintenance Rroorr OraorLrotion p.c.No., Joo No..~ra.3.Work Performed by Owner Type Cods Symbol N/A Authorization N/A Expiration Oats N/A 4.Identification of System 1-62A Class I Reactor Head&Auxilia S stems 5.(a)Appecable Construction Code ASME III 19 71 Edition, Wr72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Aorrlacamonta 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Coinponents Code Case Item (s)Susquehanna Work Authorization Number Code Repair Form No.Y40145 Y40260 Y40260 I 95-1 62-048 19 5-1 62-045 I95-162-045 Y40092 I95-1 62-023 Y40092 H40198 Y40262 I 95-1 62-023 I95-1 62-01 1 I95-1 62-051 Y40262 I95-1 62-051 10 Y40093 Y40093 Y40265 I95-162-010 I95-162-052 l9 5-1 62-060 12 Y40265 I95-1 62-060 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 62A-I 1.Owner 2.Plant Pennsylvania Power 5.Light Co.Nomo Two North Ninth St., Allentown. PA 18101 Arrdreoo Sus uehanna Steam Electric Station Nomo Oate Sheet Unit 05/18/95 6 oF PO Box 467, Berwick, PA 18603 Maintenance Aooair Oreonisotion P.O.No., Joe No..oio.3.Work Performed by Owner Homo Type Code Symbol Authorization N/A N/A Expiration Date N/A 4.Identification of System 1-62A Class I Reactor Head 8t Auxilia S stems 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Repieceinents 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Item (s)Susquehanna Work Authorization Number Code Repair Form No.13 Y40265)95-1 62-055 14 15 Y40265 Y40093 Y40093)95-162-055 I95-1 62-009 I95-162-009 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 164B-l 1.Owner Pennsylvania Power 5.Light Co.Name Two North Ninth St., Allentown, PA 18101 Date Sheet 1 05/1 8/95 of 2.Plant Susquehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Add<ceo Unit Maintenance/WA ¹See Sheet 3 of 3 Reoaa Organcaaon P.a.No., Job No..ato.3.Work Performed by Owner Name Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-648 Class I Reactor Recirculation S stem N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs ar Replacements 19'89 No Add.6.Identification af Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of.Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes ar No)Item 1 1 Load Stud Grinnell Item¹13'(1)NIA SPDCA102H20 REPLACED NO Item 2 1 Load Stud 1 Heavy Hex Nuts 1 Heavy Hex Nuts Grinnell Grinnell Grinnell Item¹13'(1)Item¹14'(1)Item¹14'(1)N/A N/A N/A SPDCA102H20 SPDCA102H20 5 P DCA102H20 REPLACEMENT REPLACED REPLACEMENT No No'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. snubber.7.Description of work Replaced arts with sufficient re lacem nt parts and oun 1/16" rom cl m Replaced existing sn~ex wi 8.Tests Conducted: Hydrostatic ~Pneumatic Q Nominal Operating Pressure Q ef NOTE: Supplemental sheets in farm of lists, sketches, or drawings may be used, provided (1)size is 8/i in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this farm.(12/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Remarks N/A Aopticeol~M entilectvier'e octo Reoorte lo oe eltecned CERTIFICATION OF COMPLIANCE We certify that tho statements made in the report are correct and this<<~rr<<otecernent conforms to the rules of the ASME Code, Secdon XI.Renw or Reoiecernent Typo Code Symbol Stamp Signed Cord/Icato of Authorizadon No.N/A Owner or owner'e eeietnee, Title V.P.~NVCLEAR OPERATIONS N/A Expiradon Date Oato N/A 2-g-, 19 95~~CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the Notional Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAl.INSURANCE CO.of.WALTHAM MASSACHUSETTS havo inspected the components described-in this Ovrnor's Report during the period 03/25/95 to 05/06/95 , and state that, to tho best of my knowledge and belief, the Owner has por/ormod examinadons and taken corrective measures described in this Owner's Report in accordance with the requiremonts of the ASME Cade,Section XI.By signing this cortiticate neither the Inspector nor his employer makes any warranty, expressed or implied.concerning the examinadons and corrective moasuros described in this Owner's Report.Funhermoro, neither tho Inspector nor his employer shall be liablo in any manner for any personal injury or property damage or a lass of any kind arising from or connocted with this inspection. CTdAY MUTUAL ENQ ASSdd.Commissions 8'&/National Board, State, Province, and Endorsements Inspector's Signature Oats: FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1 648-l 2.Plant Pennsylvania Power 5 Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Address Date 05/18/95 Sheet 2 of Unit Maintenance/WA ¹See Sheet 3 of 3 Raoarr Orcaraaarrora p.c.rro, Joir Noetc.3.Work Performed by Owner Type Code Symbol N/A Authorization N/A 4.Ident(fication of System Expiration Date 1-64B Class I Reactor Recirculation S stem N/A 5.(a)Applicable Construction Coda ASME III 19 71 Edition, W'72 Addenda N/A (b)AppEcable Edition of Section XI Utilized for Repairs or Rarrlacamanis 19'89 No Add.6.Identii)cat(on of Components Repaired or Replaced and Replacement Components Code Case Name of Component Naine of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 3 1 Pivot Pin Grinnell Item¹6'(1)N/A RWS100H49 REPLACED No 1 Pivot Pin Grinnell Item¹6'(1)N/A RWS100H49'(1)REPLACEMENT NO Item 4 ITem 5 Grind Clamp Mech Shock Arrester Grinnell Pacific Scientific Item¹12'(1)7227 N/A NIA RWS100H12 OCA102H3 1978 REPAIR REPLACED NO YES Mech Shock Arrestor Pacific Scientific 19548 N/A OCA102H3 1981 REPLACEMENT YES'NOTE(l): SERIAL/HEAT NUMBER ANO YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1 648-I 1.Owner Pennsylvania Power 5.Light Co.ri arne Oate 05/18/95 Two North Ninth St., Allentown. PA 18101 Sheet 3 of 2.Plant Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Addreaa Unit Maintenance Aeow orcaniaarion p.o.rio..Joe Ho..eie.3.Work Performed by Owner Mama Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Oate 1-648 Class I Reactor Recirculation S stem N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Itoplocomente 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Item (s)Susquehanna Work Authorization Nuinbsr Code Repair Form No.Y40109 I95-164-049 Y40109 l95-1 64-049 Y40097 Y40266 Y40177 I95-1 64-008 l95-164-066 I95-183-030 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 73 C-II 1.Owner Pennsylvania Power&Light Co.Data 05/1 8/95 Two North Ninth St., Allentown. PA 18101 Sheet 1 of 2.Plant Sus uehanna Steam Electric Station Name PO Box 467, Serwick, PA 18603 AdCheaa Unit Maintenance/WA S'40333 Ranair crcanitaaon p.c.No..Jab No..ate.3.Work Performed by Owner Name Type Code Symbol Authorization N/A N/A Expiration Date N/A 4.Identification of System 1-73C Class II Containment Atmos here Control S stem 5.(a)Applicable Construction Cods ASME III 19 71 Edition, W'72 Addenda N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced.or Replacement ASME Cods Stamped (Yss or No)1 Load Stud 1 Load Stud Grinnell Grinnell Item 0 13'(1)Item Si 13'(1)N/A N/A SPHCB122H2005 '(1)REPLACED SPHCB122H2005 '(1)REPLACEMENT NO NO 1 Pivot Pin Grinnell Item f 6'(1)N/A SPHCB122H2005 '(1)REPLACED NO 1 Pivot Pin 2 Heavy Hex Nuts 2 Heavy Hex Nuts Grinnell Grinnell Grinnsll Item S(1)Item Il 14'(1)Item 4 14'(1)NIA NIA N/A SPHCB122H2005 '(1)REPLACEMENT SPHCB122H2005 a(1)REPLACED SPHCB122H2005 (1)REPLACEMENT NO NO No'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. 7.Description of Work Re laced parts with sufficient re lacement arts.8.Tests Conducted: Hydrostatic Pneumatic P Nominal Operating Pressure Q Exempt PX Pressure psi Test Temp.ef NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8A in.x 11 in..(2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this farm.(12/82)10017 This form (E00030)may be obtained from ths Order Dept., ASME, 345 E.47th St., Nsw York, N.Y FORM NIS-2 (Back)9.Remarks N/A Antteceet~Metettecttttet e Oet~Aenette te tte ettecnee CERTIFICATION OF COMPLIANCE We certify that the statements made in the report aro corroct and this ASME Code,Section XI.tedecement conforms to the rules of the Aennt et Aentecement Type Cade Symbol Stamp N/A Certificate of Authorizyion No.N/A Expiration Oats N/A Signo net et a ne/'e oeetttnee. Title v.p.~NUcLEAR optRATioNs t Date ,19 95 CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors end the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 03/25/95 to 05/06/95 , end state that to the bast of my knowledge and belief, the Owner has performed examinations and takon corrective measures described in this Ownor's Report in accardanco with the requiremonts of the ASME Cade,Section XI.By signing this certificate neither tho Inspector nor his employer makes any warranty, exprossed or implied, concerning the examinations and corroctivo moasuros described in this Owner's Roport.Furthermore, noither tho Inspoctor nor his employer shell bo liable in any mannor for any porsonal injury or property damage or a loss of any kind arising from or connected with this inspection. FACTORY MUTUAL ENQ ASSOC.Inspector's Signature Commissions National Board, State, Provinco, and Endorsoments Oats: I 19 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 5.Light Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station Sheet Unit of PO Sox 467, Serwick, PA 18603 Address MaintenancelWA S See Sheet 3 of 3 Aeosit ordsrsssuon p.o.iio.~Jou iio., sic.3.Work Performed by Owner Type Code Symbol N/A Authorization N/A 4.Identification of System Expiration Date 1-83A Class I Main Steam Lines N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 (b)Appiicabla Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Addenda Code Casa Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)RBII)l.2 Heavy Hex Nuts 2 Heavy Hex Nuts 2 2 Heavy Hex Nuts 2 Heavy Hex Nuts Grinnell Grinnell Grinnell Grinnell Itein 4 14'(1)Item 4 14'(1)Item S'4'(1)Item 4 14 (1)N/A N/A N/A N/A SPOCA149H2003 '(1)SPDCA149H2003 '(1)SPDCA149H2006 '(1)SPOCA149H2006 '(1)REPLACED NO REPLACED NO REPLACEMENT REPLACEMENT No 1 Load'Stud 1 Load Stud Grinnell Grinnell Item//13"(1)Item 4 13'(1)N/A N/A SPDCA148H2010 '(1)SPDCA148H2010 (1)REPLACED NO REPLACEMENT No'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. 7.Description of Work Re laced arts with sufficient re lacement arts.8.Tests Conducted: Hydrostatic Pneumatic Q Exempt Qx Pressure Nominal Operating Pressure Q psi Test Temp.OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8/s in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(12/82)10017 This form (E00030}may be obtained from the Order Dept., ASM'E, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Remarks N/A Aoodcebte Menurecttrrer' oete Reoorte te tre ettecned CERTIFICATION OF COMPLIANCE Wo cortify that the statements made in the report are correct and this reelecernent conforms to the rules of the ASME Ccdo,Section XI.Aeoerr er Reolecernent Typo Code Symbol Stamp N/A Certificate of Authorization Nc.r Q Signed N/A wner Oerner'Oeeetnee.Tide V.p.NVCLEArt CptRAttcMS Expiration Oste N/A Qsts~~2./, 19 95'CERTIFICATION OF INSERVICE INSPECTION I~the undersigned, holding a valid commission issued by tho National Board of Boiler and Pressure Vessel Inspectors and the Stato or Provinco cf PENNSYLVANIA and employed by ARKWRIQHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUS~S have inspected the components described in this Owner's Report during tho period 03/25/95 tc 05/06/95 , and state that to the bast of my knowledge and bolief, the Owner has porformed examinations and taken corrective measures doscribed in this Owner's Report in acccrdonce with the requirements of tho ASME Ccdo,Section XI.By signing this certificate neither the Inspector nor his emplcyor makes any warranty, exprossed or implied, concerning the exominations and ccrroctivo measures described in this Owner's Report.Furthermore, neither tho Inspector ncr his employer shall be liablo in an manner for any personal injury or property damago or a loss of any kind arising from or ccnnoctod with this inspectic.FA ORY MUTUAL ENO ASSOC.Commissions Ps x 5 National Board, State, Province, and Endcrsements Inspector's Signature Date: FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 83A-I 1.Owner Pennsylvania Power&Li ht Co.Date 05/1 8/95 Two North Ninth St., AIIentown, PA 18101 Sheet 2 of 2.Plant Susquehanna Steam Electric Station PO Box 467, Berwick, PA 18603 Ace heee Unit Maintenance/WA ¹See Sheet 3 of 3 Recce Ocgeoiseeon p.O.No., Joe No., eic.3.Work Performed by Owner iieme Type Cods Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83A Class I Main Steam Lines N/A 5.(s)Applicable Construcdon Code ASME III 19 71 Edition, W'72 (b)Applicable Edition of Section XI Utilized for Repairs or Replecements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Addenda Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 4 2 Heavy Hex Nuts Grinnell Item¹14'(1)NIA SPDCA148H2010 REPLACED NO 2 Heavy Hex Nuts Grinnell Item¹14'(1)N/A SPDCA148H2010 REPLACEMENT No e 5 1 Pivot Pin 1 Pivot Pin Grinnell Grinnell Item¹6'(1)Item¹6'(1)NIA N/A SPDCA148H2009 SPDCA148H2009 REPLACED REPLACEMENT NO NO'NOTE(1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power 5.Li ht Co.Nome Date 05/1 8/95 2.Plant Two North Ninth St..Allentown, PA 18101 Aeeieee Susquehanna Steam Electric Station Nome PO Box 467, Berwick, PA 18603 Sheet 3 of Unit Maintenance Reoeo Ozgenixeiion P.O.No., Joe No., eto.3.Work Performed by Owner Name Type Coda Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83A Class I Main Steam Lines N/A 5.ia)Applicable Construction Code ASME Itl 19 71 Edition, tw'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identlficaoon of Components Repaired or Replaced and Replacement Components Code Case Item (s)Susquehanna Work Authorization Number Code Repair Farm No.Y40120 Y40304 Y40302 I95-183<04 I95-183-038 195-183-040 Y40302 l95-183%40 Y40302 I95-183<41 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI't 83A-II 1.Owner Pennsylvania Power 8t Light Co.Nome Two North Ninth St., Allentown, PA 18101 Date Sheet 05/1 8/95 1 of 2.Plant Sus uehanna Steam Eiectric Station Noma PO Box 467, Berwick, PA 18603 Address Unit Maintenance/WA 4 See Shoot 3 of 3 Recorr Orcorssouon p.c.No..Jou No, eic.3.Work Performed by Owner Nemo Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83A Class II Main Steam Lines N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 18'89 No Add.B.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)tern 1 1 Pivot Pin Grinnell Item 0 6'(1)NIA DBB102H12A (1)REPLACED No 1 Pivot Pin Teal 2 1 Pivot Pin 1 Pivot Pin Grinnell Grinnoll Grinnell Item O'(1)Item 4 6'(1)Item 4 6 (1)N/A N/A NIA OBB102H12A '(1)OBB103H7A DBB103H7A REPLACED NO REPLACEMENT NO REPLACEMENT NO Tettt 3 1 Pivot Pin 6rinnell Item 0 6 (1)N/A OBB104H13A REPLACED NO 1 Pivot Pin Grinnell Item 4 6'(1)N/A DBB104H13A REPLACEMENT NO'NOTE (1): SERIAL/HEAT NUMBER ANO YEAR BUILT NOT AVAILABLE. 7.Ooscription of Work Re laced arts with sufficient replacement arts.8.Tests Conducted: Hydrostatic Pneumatic Q Nominal operating Pressure Q Exempt Qx Pressure psi Test Temp.OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8%in.x 11 in., (2)informs tion in items 1 through 6 on this repon is included on each sheet, and (3)each sheet is numbered and the number of sheets i rocorded at the top of this form.(1 2/82)10017 This form (E00030)may bo obtained from the Order Dept., ASME, 345 E.47th St., Now York, N.Y FORM NIS-2 (Bacit)9.Remarks N/A Aoooosee M uwisenees' Os(s Aeoons<o oe~e sensa CERTIFICATION OF COMPLIANCE We certify that the statements made in tho report are correct and this'~<<erne<<conforms to the rules of the ASME Code,Section XI.Reow or Reolscemenr Type Codo Symbol Stamp N/A Certificate of Authorization No.'/A Sign Owner osjo ner'e Oendnee.Tide V.P.~Nuctann OPERAtIONS Expiration Date Date N/A CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Prossure Vessel Inspectors and the Stats or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.of.~WALTHAM MASSACHUSEYI'S have inspected the components described>> in this Ownor's Report during the period 03/25/95 to 05/06/95 , and state that, to tho best of my knowledgo and belief, the Owner has performed examinations and taken corrective measures described in...this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this cerriflcate neither tho Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons end corrective measures described in this Owner's Report.Furthermore. neither the inspector nor his employer shall be liablo in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ACTORY MUTUAL EIIQ ASSOC.Commissions Date: Inspector's Signature , 19~M National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 83A-II 1.Owner Pennsylvania Power&Light Co.N NEO Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Sus uehanna Steam Electric Station N emu PO Box 467, Berwick.PA 18603 Addicts Sheet 2 of Unit MaintensncelWA O'ee Sheet 3 of 3 Aeue i oidenzsuon p.o.Mo., Jou Nd., oid.3.Work Performed by Owner NMlu Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83A Oass il Main Steam Lines N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Ib)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Nsine of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped IYes or No)tern 4 Mech Shock Arrestor Pacific Scientific 'I 7243 NIA SPOBB108H2008 1983 REPLACED NO Mech Shock Arrestor Pacific Scientific 13433 NIA SPDBB108H2008 1981 REPLACEMENT NO tern 5 Mech Shock Arrestor Pacific Scientific 02422 NIA 088104H18 1990 REPLACED No Mech Shock Arrester Pacific Scientific 00552 NIA 088104H18 1973 REPLACEMENT NO'NOTEI1): SERIAL/HEAT NUMBER AND YEAR BUILT NQT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I 83A-ll 1.Owner 2.Plant Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Address Oats 05/1 8/95 Sheet 3 of Unit Maintenance Reparr Oreaeiaation P.O.No., Joe No.,~ic.3.Work Performed by Owner Name Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Oats 1-83A Class II Main Steam Lines N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Item (s)Susquehanna Work Authorization Number Code Repair Form No.Y40151 Y40153 I95-183-056 I95-183<42 Y40154 (9 5-1 83-043 Y40279 Y40156 I95-183-026 l95-183-063 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1 83D-ill l.Owner Pennsylvania Power&, Light Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Address Sus uehanna Steam Electric Station N arne Sheet Unit 1 of PO'Sox 467, Serwick, PA 18603 Maintenance/WA ¹See Sheet 3 of 3 Repair Orqaniaapon P.O.No., Jerr No.~~ie.3.Work Performed by Owner Name Typo Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-830 Class III Main Steam S stems N/A 5.(s)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Coda Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Codo Stamped (Yes or No)tern 1 2 Heavy Hex Nuts 2 Heavy Hex Nuts Grinnell Grinnell Item¹14'(1)Item¹14 (1)N/A N/A GBC101H272 '(1)GBC101H272 '(1)REPLACED No REPLACEMENT NO:tern 2 1PivotPin 1 Pivot Pin tern 3 Grind Clamp Grinnell Grinnell Grinnell Item¹6'(1)Item¹6'(1)Item¹12'(1)NIA N/A NIA GBC101H193 GBC101H193 '(1)GBC101H193 REPLACED REPLACEMENT r REPAIR No No No'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. 7.Description of Work Re laced arts with sufficient replacement arts and round 1/16" of steel from clam Replaced existing spqbber with game s3.ze, unct3.ona es e rep acement 8.Tests Conducted: Hydrostatic ~Pneumatic g Nominal Operating Pressure snubber.Exempt Qx Pressure psi Test Temp.ef NOTE: Supplemental sheets in form af lists, sketches, or drawings may be used, provided (1)size is 8)rs in.x 11 in., (2)informs tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number af sheets i recorded st the top of this form.(1 2/82)10017 This farm (E00030)may be obtained fram the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 IBack)9.Remarks N/A Aooscable M anadacturer's Oal~Reoens re be aoacnec O'ERTIFICATION OF COMPLIANCE We certify that the statements mado in the report are correct and this<<PNrr<<oracam<<c conforms to the rules of the ASME Code,Section XI.Reow er Reolacemenc Type Code Symbol Stamp N/A Certilicato of Authorization No.N/A Expiration Oats N/A Sighted Owner Ov/ner's Oeseonee.lido V.P.NUCLEAR OPGlAlloNS r/Oato ,19 95 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIQHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUSETTS have inspected the components described" in this Owner's Report during the period 03/25/95 to 05/06/95 , and state that, to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this cerificate neither the Inspector nor his employor makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall bo liable in sny manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. F CTCAY MUTUAL ENQ ASSOC.Commissions u'//Nauonal Board, State, Provinco, and Endorsements Inspector's Signature Oatet.IS~M FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1 83D-III 1.Owner Pennsylvania Power&Light Co.Data 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Adokeaa Sus uehanna Steam Electric Station Name PO Box 467, Berwick, PA 18603 Sheet 2 of Unit Maintenance/WA f See Sheet 3 of 3 Reoaa Otsanitaoon P.O.No., Joe No eio.3.Work Performed by Owner Name Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83D Class III Main Steam S stems N/A 5.(a)Appiicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or iteplocomonts 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Item 4 1 Pivot Pin Grinnell Item/r 6'(1)N/A GBC101H147 '(1)REPLACED No 1 Pivot Pin Item 5 1 Load Stud Grinnell Grinnell Item 4 6 (1)Item 4 13 (1)N/A N/A GBC'I 0 1 H147'(1)GBC101H272 '(1)REPLACEMENT REPLACED NO No 1 Load Stud Grinnell Item f/13'(1)N/A GBC'l01H272 '(1)REPLACEMENT NO Item 6 Mach Shock Pacific, Scientific 1332 N/A GBC101H233 1978 REPLACED NO Mech Shock Arrester Pacific Scientific 10888 N/A GBC101H233 1982 REPLACEMENT No'NOTE(l): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI 1 83D-II1 l.Owner Pennsylvania Power 5.Light Co, Name Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Ad dr oaa Sus uehanna Steam Electric Station N arne PO Box 467, Berwick, PA 18603 Sheet 3 of Unit Maintenance Repair Orrrarerauon P.O.No..Jorr Noeic.3.Work Performed by Owner Type Code Symbol N/A 4.Identification of System Addheaa Authorization Expiration Oats 1-830 Class III Main Steam S stems N/A N/A 5.(a)Applicable Construction Cods ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Casa Item (s)Susquehanna Work Authorization Number Code Repair Form No.Y40081 Y40081 I95-183<46 I95-183-047 Y40081 Y40224 I95-183-047 I95-183-044 Y40081 I95-183-022 Y40277 I95-183-062 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI'1 83 E-I I I 1.Owner 2.Plant Pennsylvania Power 5 Light Co.Home Two North Ninth St., Allentown. PA 18101 Address Sus uehanna Steam Electric Station Meme PO Box 467, Berwick.PA 18603 Address Date 05/1 8/95 Sheet 1 of Unit Maintenance/WA s'40198 Rerrerr Cr genre eden P.O.Ho., Joe No..eic.3.Work Performed by Owner Nome Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83E Class III Main Steam S stem N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Aoplacomcnts tg'89 No Add.6.Identificat(on of Components Repaired or Replaced and Replacement Coinponents Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Buiit Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)Mech Shock Mech Shock Arrestor Pacific Scientific Pacific Scientific 16396 23570 N/A N/A SPHCC138H2008 SPHCC138H2008 1980 1981 REPLACED REPLACEMENT No No 7.Description of Work Re laced existinsnubber with same size, functionall tested re lacement snubber.8.Tests Conducted: Hydrostatic Pneumatic Q Nominal Operating Pressure Q-.*o oF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used.provided (1)size is 8)rr in.x 11 in., (2)informa tion in items 1 through 6 on this report is included on each sheet.and (3)each sheet is numbered and the number of sheets i recorded at the top of this form.(1 2/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St.~New York, N.Y FORM NIS-2 Iaack)9.Remarks N/A*Dtteeeel~rrtenureeturer ~oet~Reoerte te ee~ttecned CERTIFICATION OF COMPLIANCE We certify that the statements made in tho report aro correct and this conforms to the rules of the ASME Code,Section XI.Rettw er Aettteeement Type Code Symbol Stamp N/A Cerdficate of Authojzadon No.N/A Expiration Date N/A Sign owner owner'e Oeetotee.litte v.rt.-Nuctsrtrt opERAttorts l Date t, r.~+f, 19 95 CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the National Board of Bailer and Pressure Vessel inspectors and the State or Province of PENNSyLVANIA and employed by ARKWRICHT MUTUAL INSURANCE CO.ot WALTHAM MASSACHUSEITS have inspected the components described'n this Owner's Report during the period 03/25/95 to 05/06/95 , and state that, to the best of my know(edge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. yp,croRv MUTUAL ENa assoc.Commissions AJ8'.~Ah 4'lAJ/I Inspector's Signature National Board, State, Province, and Endorsements Date: C~WZ, 19~& FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI't 83F-I l.Owner 2.Plant Pennsylvania Power&Light Co.Name Two North Ninth St., Allentown. PA 18101 Addraaa Sus uehanna Steam Electric Station Name Date Sheet Unit 05/18/95 1 of PO Sox 467, Serwick, PA 18603 Maintenance/WA S'ee Sheet 2 of 2 Aedarr Organiaatian P.O.NO., Jab Ne..ere.3.Work Performed by Owner Name Type Code Symbol Authorization N/A N/A 4.Identification of System Expiration Date 1-83F Class I Main Steam S stem N/A S.(a)Applicable Construction Code ASME III 19 71 Edition, Wr72 (b)Applicable Edition of Section XI Utilized for Repairs or Rcplccaments 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Addenda Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.othor Identification Year Built Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No).tern 1 Mech Shock Arrester Pacific Scientific 4191 N/A S POCA1 27H1 56 1978 REPLACED YES Ltem 2'.tern 3.tern 4"tern 5 Mech Shock Arrestor Pacific Scientific Mech Shock Arrestor Pacific Scientific Mech Shock Arrestor Pacific Scientific Mech Shock Arrestor Pacific Scientific 23591 23571 27922 10948 NIA NIA N/A NIA SPOCA127H156 SPDCA127H161 SPOCA127H1 61 SPOCA128H138 1978 REPLACED 1982 REPLACEMENT 1979 REPLACED 1981 REPLACEMENT NO NO NO NO Etem 6 Mech Shock Arrester Pacific Scientific 16424 N/A SPDCA128H138 1980 REPLACEMENT NO 7.Description of Work ReplaCed eXiStinSnubberS With Same SiZe, funCtiOnall teSted replaCement SnubberS.8.Tests Conducted: Hydrostatic Pneumatic Q Nominal Operating Pressure Q Exempt px Pressure psi Test Temp.ef NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 ja in.x 11 in..(2 informs-tion in items 1 through 6 on this report is included on each sheet.and (3)each sheet is nuinbered and the number o sheets is recorded at the top of this farm.(12/82)10017 This form.(E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y FORM NIS-2 (Back)9.Romarks N/A Appaoaaae Manarracrurv' Oara Aepona ao Oe aoaoneo CERTIFICATION OF COMPUANCE Wo cerdfy that tho statements made in the report are correct and this repraeemenr conforms to the rules of the ASIjriE Code,Section XI.Repw v Replacemenc Typo Code Symbol Stamp N/A Certificate of Authorizadon No.N/A Expiration Oate N/A Signed Owner Ow'a Oenpnee.Tide V.P.NUCt&IR OptitATtoNS ,19 95 CERTIFICATION OF INSERVICE INSPECTION J I, tho undorsigned, holding a valid commission issued by tho Nadonal Board of Boiler and Pressure Vessel inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUSETTS have inspected tho components described in this Owner's Report during tho period 03/25/95 to 05/06/95 , and state that to tho best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Ownor's Report in accordance with the requirements of the ASIVIE Codo,Section XI.By signing this ceaificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correctivo measuros described in this Owner's Report.Furthermore. neither tho Inspector nor his employer shall bo liable in any mannor for any personal injury or property damage or a loss ot any kind arising from or connected with this inspection. FACTORY MUTUAL ENQ ASSOC.Commissions KiQ C, P4S/9 Nagonal Board, State, Province, and Endorsements Inspector's Signature FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 183F-I 1.Owner Pennsylvania Power 5.Light Co.Name Oats 05/18/95 2.Plant Two North Ninth St., Allentown, PA 18101 Addi<<a<<Sus uehanna Steam Electric Station Sheet 2 of Unit PO Box 467, Berwick, PA 18603 Addio<<a Maintenance Reoaia Ores6<<aden P.O.No..doe Noet<<.3.Work Performed by Owner Name Type Cods Symbol Authorization N/A N/A 4.Identification of System Expiration Oats 1-83F Class I Main Steam S stem N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacement<< 19'89 No Add.6.Identificadon of Components Repaired or Replaced and Replacement Components Code Case Item (s)Susquehanna Work Authorizadon Number Code Repair Farm No.Y40'114 l95-183-01 5 Y40114 (95-183-015 Y401 14 Y40114 Y401 17 195-183-01 6!95-183.01 6 195-183.014 Y401 17 l95-183-014 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI l.Owner Pennsylvania Power (It Light Co.Oats 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Addrees Sus uehanna Steam Electric Station Sheet 1 of Unit PO Box 467, Berwick, PA 18603 Maintenance/WA ¹See Sheet 3 of 3 Reoeii Orqenrreaon p.c.Ho.~Joir Ho., eio.3.Work Performed by 4.Identification of System Address Owner Nome Type Code Symbol Authorization Expiration Date 1-83H Oass II Main Steam S stems N/A N/A N/A 5.(a)Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Coinponents Code Casa Name of Component Naine of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired, Replaced, or Replacement ASME Code Stainped (Yes or No)tern 1 1 Load Stud 1 Load Stud Grinnell Grinnell Item¹13 (1)Item¹13'(1)N/A N/A SPDBB124H4 REPLACED SPOBB124H4 '(1)REPLACEMENT NO NO tern 3 1 Pivot Pin Grinnell Item¹6'(1)N/A SPDBB124H4 '(1)REPLACED No tern 4 1 Pivot Pin Grinnell Item¹6 (1)N/A SPDBB124H4 '(1)REPLACEMENT NO'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE. 7.Description of Work Re laced arts with sufficient re lacement arts.Replaced ex3.staring spy ers w3.~arne s3.ze, unc 3.8.Tests Conductedt Hydrostatic ~Pneumatic g Nominal Operating Pressure Q Exempt Qx Pressure psi Test Temp.op ent snubbexs.NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8)rr in.x 11 in., (2 informs-tion in items 1 through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number o sheets is recorded at the top of this form.(12/82)10017 This form (E00030)may be obtained from the Order Dept., ASME, 345 E.47th St., New York.N.Y FORM NIS-2 (Back)9.Remarks N/A Aooiiaaole M anuiacaiirar' cata Raoona ro oe err acned CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Cade,Section XI.Raow or Raoraearnanr Typo Code Symbol Stamp N/A Certificate of Authorization No.N/A Expiration Date N/A Signed Owner p Ow'a Oeairrnae. jide V.P.~NUCLEAR OPGlATlorra Oate ,19 95" CERTIFICATION OF INSERVICE INSPECTION Inspector's Signature I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressuro Vessel inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO.of WALTHAM MASSACHUSETl S have inspected the components described in this Ownor's Report during the period 03/25/95 to 05/06/95 , and state that to tho bost of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the oxaminadons and correctivo measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ACTOIty MUTUAL ENQ ASSOC.Commissions M(/National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.Owner Pennsylvania Power, Itt Li ht Co.Date 05/1 8/95 2.Plant Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station PO Box 467, Berwick, PA 18603 Address Sheet 2 of unit Maintenance/WA Ir See Sheet 3 of 3 Repair Ordaniraoon p.c.No., Joir rro..eto.3.Work Performed by Owner Type Code Symbol N/A Authorization N/A 4.Identification of System Expiration Date 1-83H Class II Main Steam S stems N/A 5.Ia)Applicable Construction Code AS ME III 19 71 Edition, W'72 Addenda Ib)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.6.Identification of Components Repaired or Replaced and Replacement Components Code Case Name of Component Name of Manufacturer Manufacturer Serial No.National Board No.Other Identification Year Built Repaired.Replaced, or Replacement ASME Coda Stamped IYes or No)5 Mech Shock Arrestor Pacific Scientific 5010 N/A SPDBB125H3 1978 REPLACED NO Item 6 Mech Shock Arrestor Pacific Scientific 18577 NIA SPDBB125H3 1981 REPLACEMENT Item 7 Mech Shock Arrestor ITem 8 Mech Shock Arrester Pacific Scientific Pacific Scientific 10918 28856 N/A NIA SPGBB134H3 SPGBB134H3 1979 1982 REPLACED NO REPLACEMENT YES FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI 1 83H-II l.Owner Pennsylvania Power 5.Light Co.Oats 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 3 of 2.Plant Sus uehanna Steam Electric Station Nome PO Box 467, Berwick, PA 18603 Addreee Unit Maintenance Aepeir Crcenireeon p.c.No..Job No., ero.3.Work Performed by Owner Type Cade Symbol N/A 4.Identification of System Authorization Expiration Oats 1-83H Class II Main Steam S stems N/A N/A 5.(s)Applicablo Construction Code ASME III 19 71 Ediuon, W'72 Addenda (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19'89 No Add.8.Identification of Components Repaired or Replaced and Replacement Components Cods Case Item (s)Susquehanna Work Authorization Number Cods Repair Form No.Y40280 I95 183-037 Y40280 I95-183-037 Y40280 Y40280 Y4o1os l95-183<37 I95-183-037 l95-183%20 Y40106 Y40320 Y40320 l95-183<20 I95-183-029 I95-183-029 REACTOR PRESS&RE VESSEL EXTERNAL EXmwrrNAnOXS Susquehanna Steam Electric Station Unit I RPV Inservice Examination Eighth Refueling and Inspection Outage Report of Examination Results Owner: Plant: Pennsylvania Power and I.ight Company Two North Ninth Street Allentown, PA 18601 Susquehanna Stcam Electric Station Unit 1 P.O.Box 467 Berwick, PA 18603 Commercial Service Date: June 8, 1983 Ratings: 3,293 iilwt 1,084.8 ltWWe Manufacturer: Chicago Bridge and Iron Company National Board Number: 3686 Prepared By: W.F.Miller Sr.iVDE Specialist GEVLE, iVPScSD Inspection Services Reviewed By: R.A.Seals Project Manager GEiiE, MUSD Inspection Services Ap ave y'I.%Stet ass ISI Supervisor PPScL Company Susquehanna Steam Electric Station REACTOR PRESSURE VESSEL EXTERNAL EXAiVIIINATIONS SUSQUEHAi tNA STEAiVl ELECTRIC STATION UNIT 1 RP V INSERVICE EXAiMNATON EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAiMNATION RESULTS TABLE OF CONTENTS SECTION I SECTION II SECTION III SECTION IV INTRODUCTION SCOPE OF EXAMS WITH WELD LOCATION DRAWINGS

SUMMARY

TABLES AND RECORDABLE INDICATION DATA

SUMMARY

REPORTS SUSQUEHAi tNA STEAiVT ELECTRIC STATION UMT 1 RPV INSERVICE EcXA~ii ATION EIGHTH REFUELING Ai~INSPECTION OUTAGE REPORT OF EXAiVGNATION RESULTS SECTION I INTRODUCTION SUSQUEHAi~tA STEAiVl ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVQNATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAMINATION RESULTS SECTION I INTRODUCTION This report contains the results of the inservice examinations performed on the Susquehanna Steam Electric Station Unit 1 Reactor Pressure Vessel.National Board No.3686, during the Eighth Refueling and Inspection outage.Examinations were performed in the period&om March 25, 1995 through lilay 6, 1995.The examinations were performed in accordance with the requirements of: The ASiiE Boiler and Pressure Vessel Code, 1989 Edition, without Addenda.a.Section V, Nondestructive Examination.

b.Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components-Division 1.2.United States Code of Federal Regulations, Title 10 Energy.a.10CFR21 b.10CFR50 Apendix B c.10CFR50 Subpart 55 United States Nuclear Regulatory Commission Documents a.Regulatory Guide 1.150 Ultrasonic Testing of Reactor Vessel Welds during Preservice and Inservice Examinations, Revision 1, Alternate method.b.NUREG 0619 BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking.American Society for Nondestructive Testing (ASNT)Documents a.SNT-TC-1A Personnel Qualification and Certification for Nondestructive Testing, 1984 Edition.

Pennsylvania Power and Light Co.ISI Program Documents a.ISI-T-106/206 Revision 0,"Inservice Inspection Program Plan For The Second.Inservice Inspection Interval".

b.ISI-T-108/208 Revision 0,"Class 1, 2, and 3 Components And Component Supports For The Second Inservice Inspection Interval".

Examinations were performed on ASiVEE Section XI Category B-A, B-D, B-G-2 and B-J Components.

Augmented examinations were performed on PP&L Category AUG-2 and AUG-3 Components.

Remote Automated Ultrasonic examinations were performed on accessible portions of RPV shell assembly welds, RPV nozzle to vessel welds, RPV nozzle inside radiused sections, RPV nozzle bore sections, and RPV nozzle to safe end welds.The examinations were perfotmed from the outer surface of the components.

The items examined are listed in Section II.Manual Ultrasonic, Magnetic Particle and Visual (VT-I)examinations were performed on accessible portions of RPV shell assembly welds, RPV nozzle to vessel welds, RPV nozzle to safe end welds and RPV bolting.The examinations were performed&om the outer surface of the components.

The items examined are listed in section II.Original examination data, calibration data, personnel certifications, equipment certifications,.

material certifications, examination procedures, drawings, and evaluations that pertain to these examinations are being retained by PP&L.These documents are controlled by PP&L and are available for review at the Susquehanna site.A Summary Table for each examination performed, appears in Section III of this Report.Summary Reports containing the Regulatory Guide 1.150 required documentation, the description of examination coverage, the comparison of results with those of previous examinations, and a description of equipment characteristics appear in Section IV of this Report.

SUSQUEHANNA STEAiM ELECTRIC STATION UNIT 1 RPV INSERVICE EXYiVIVfATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EX.&IINATION RESULTS SECTION II SCOPE OF EXAMS WITH WELD LOCATION DRAWINGS SUSQUEHAt PfA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAMINATION EIGHTH REFUELING A~1 INSPECTION OUTAGE REPORT OF EXAMINATION RESULTS SECTION II SCOPE The following items, listed by examination category, were examined during the Susquehanna Unit 1 Eighth Refueling and Inspection outage.The items examined and the examination(s) performed are listed below.The examination results are detailed in Section III of the report.The extent of examination coverage is detailed in Sections III and IV of this report.I.ASME SECTION XI Examination Category B-A items examined in accordance with ASME Section XI and USNRC Reg, Guide 1.150 requirements.

AA (RPV Circumferential Weld)AF (Shell to Flange Weld)BA (RPV Vertical Weld)BB (RPV Vertical Weld)BC (RPV Vertical Weld)Full Length 0 to 120 Partial Full Length Full Length Auto&Manual UT Manual UT Auto UT Auto&Manual UT Auto&Manual UT II.ASME SECTION XI Examination Category B-D items examined in accordance with ASME Section and USNRC Reg.Guide 150 requirements.

N1A (Weld&Inside Radius)N2A (Weld&Inside Radius)N2F (Weld&Inside Radius)N4A (Weld)Full Lenyh Full Lenyh Full Length Partial Auto&Manual UT Auto UT Auto UT Auto&Manual UT N4B(Weld)N4C (Weld)N4D (Weld)N4E (Weld)N4F (Weld)Full Length Full Length Full Length Full Length Full Length Auto&Manual UT Auto&Manual UT Auto&Manual UT Auto UT Auto UT III.ASME Section XI Examination Category B-G-2 items examined in accordance with ASME Section XI requirements.

CRD-10-31-BLT (Bolting)CRD-1043-BLT (Bolting)CRD-14-27-BLT (Bolting)CRD-14-31-BLT (Bolting)CRD-14-35-BLT (Bolting)CRD-1843-BLT (Bolting)CRD-18-59-BLT (Bolting)CRD-26-27-BLT (Bolting)CRD-30-03-BLT (Bolting)CRD-3043-BLT (Bolting)CRD-34-59-BLT (Bolting)CRD-38-15-BLT (Bolting)CRD-38-59-BLT (Bolting)CRD42-11-BLT (Bolting)CRD46-07-BLT (Bolting)CRD-46-19-BLT (Bolting)CRD-50-19-BLT (Bolting)CRD-5047-BLT (Bolting)CRD-54-15-BLT (Bolting)CRD-54-19-BLT (Bolting)8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts'8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts 8 Bolts Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 Visual VT-1 IV.ASiVEE Section XI Examination Category B-J items examined in Accordance with ASME Section XI requirements.

N4A (N-SE weld)N4B (N-SE weld)N4C (N-SE weld)N4C (N-SE weld)N4D (N-SE weld)N4E (N-SE weld)N4F (N-SE weld)Full Length Full Length Full Length Full Length Full Length Full Length Full Length Auto&Manual UT, MT Auto&Manual UT, MT Auto&Manual UT, MT Auto&Manual UT, i%IT Auto&ManualUT, MT Auto&Manual UT, MT Auto&Manual UT, MT V.PP&L Examination Category AUG 2 items examined in accordance with USNRC NUREG-0313 requirements.

These examinations were performed after MSIP application.

The Post-MSIP exams are required over and above the routine exams required by Category C of NUREG-0313.

N1B (N-SE weld)N2B (N-SE weld)N2C (N-SE weld)N2D (N-SE weld)N2E (N-SE weld)N2G (N-SE weld)N2H (N-SE weld)NSA (N-SE weld)NSA (SE to extension)

NSB (N-SE weld)NSB (SE to extension)

N8A (N-SE weld)N8A (SE to P-Seal)N8B (N-SE weld)N8B (SE to P-Seal)Full Length Full Lenyh Full Length Full Length Full Length Full Length Full Length Pamal Full Length Full Length Full Length Full Length Full Length Full Length Full Lenyh Auto UT Auto UT Auto UT Auto UT Auto UT Auto UT Auto UT Auto&Manual UT Manual UT Manual UT Manual UT Manual UT Manual UT Manual UT Manual UT VI.PP&L Examination Category AUG 3 items examined in accordance with USNRC NUREG-0619 requirements..

N4A (NIR&Bore)N4A (N-SE weld)N4B (NIR&Bore)N4B (N-SE weld)N4C (NIR&Bore)N4C (N-SE weld)N4D (NIR&Bore)N4D (N-SE weld)N4E (NIR&Bore)N4E (N-SE weld)N4F (NIR&Bore)N4F (N-SE weld)Partial Ful!Length Partial Full Length Full Length Full Length Partial Full Length Full Lenyh Full Length Full Length Full Length Auto&Manual UT Auto&ivfanuaf UT Auto&ManualUT Auto&Manual UT Auto&ManualUT Auto&ManualUT Auto&ManualUT Auto&iVfanualUT Auto&ManualUT Auto&ManualUT Auto&ManualUT Auto&Manual UT SUSQUEHAi WA STEAiVI ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVIINATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EXAiMNATION RESULTS SECTION III

SUMMARY

TABLES AND RECORDABLE INDICATION DATA SUSQUEHAi~iA STEAiVI ELECTRIC STATION UNIT 1 RPV INSERVICE EXAivZPl'ATION EIGHTH REFUELING AiVD INSPECTION OUTAGE REPORT OF EXAiVIIi ATION RESULTS EXAMINATION CATEGORY 3-A UNIT I Rpv INSERYICE EXAbinlATION EIGHTH REFUELUIG AND INSPECIION OUTAGE REPORT OP EXASILYATION RESULTS SECIION 3 CATEGORY 8-A PRESSURE RETAINING WELDS IN REACTOR VESSEL WELD TYPE WELD ID ITEM iVo.PROCEDURE REACTOR VESSEL CIRCUM FEREiVVL Bottom Head to Shell Course 1 Exam Viumber 625019 ASiVE Xl EXAlVl B 1.11 GE-ISI-t35 Rev.2 Rev.2 O'ill C 45'60'O'iV C 45o R 60'iVRI NRI NRI Com posito Auto/iifanual Exam was limited to 99.0%of the Code requirement by iVI A 8r.B and NS A 4 B nozzles.B 1.11 GF ISI435 Rcv.2 IVTTA Rev.2 45'Exam Number 45'NT NRI 625019 REG.GUIDE 1.150 60'iVRI INNER 25%ofT 60'T B 1.11 GE-ISI-t35 Rcv.2 Rcv.2 45o T Exam iVumber'45'T NRI 625019 REG.GUIDE 1.150 60o T iVRI OUTER 75%ofT 60'T iVRI i'll NO RECORDABLE INDICATIONS C>COSIPLETE EXAM R~RESTRICTED EXAM T~TRAYELDIG INDICATION PER REG GUIDE I.I 50 NT iXONTRAVELING INDICATION PER REG GUIDE l.l50 susOUEHAviNA sTEAM ELEcrRIc sTATICN UNIT I RPV UISERVICE EitAMDIATION EIGHTH REFUELLIG AND INSPECIION OUTAGE REPORT OF EXAIiUNATION RESULTS SECTION CATEGORY B-A PRESSURE RETAINING WELDS IN REACTOR VESSEL/VELD TPPE IVELD ID 1TEM No.PROCEDURE EXAM TFPE REACTOR VESSEL CIRCUI~EREliTIAL Shell Course 5 Io RPV Flange AF 00-120 Exam I'lumber 625023 B 130 I iUTA Rev.2 0'VM C$50 C 60'NRI Composite Examination, Combination of these examinations yields coverage of 100%of this segment of the weld.ASIDE XI E'fAiH GE-ISI I23 Rev.1 O'SS C AF 00-120'130 i IUD Rev.2 450 T Exam Number 454 i fT 625023 REG.GUIDE 1.150 600 T INNER 25%ofT 60'NT AF 00-1200 B 130 lid Rev.2 45'Exam Number 45'NT 625023 REG.GUIDE 1.150 600 T OUTER 75%ofT 60'fl'RI~NO RECORDABLE CIDICATIOIIS C~COSIPLETE EviAM R~RESTRICIED EXASI TRAvELDIC DIDICATION PER REC CUIDE I.I 50 IIONTRAVKLLIC INDICATION PER REG GUIDE I.ISO

SUSQUKIIANiNA STEAhl ELECTRIC STATIO,'il UiilT I RP Y INSKRYICE EXAhtINATION KtGIrrll REFUELING AND INSPECTION OUTAGE REPORT OF KXASILYATION RESULTS S ECTION 3 CATEGORY 8-A PRESSURE RETAINING WELDS IN REACTOR VESSEL O'ELD TYPE f VELD ID ITEM.V0.PROCEDURE EXrlDf TYPE REACI'OR VESSEL LONGITUDhVAL BA Exam iVumber B 1.12 GE-ISI-t35 Rev.2 04 IVII R 45'60'iVRI Auto examination was limited to 86.0%of the Code requirement Viuu by Nozzle N2K 625020 ASME XI EXAiM 00 iVM 450 N/A Manual examinations to be performed during R Ec 109.iV/A Coverage will then bc 100%.60O iV/A BA B 1.12 GE-ISI-t35 Rev.2 450 T~Exam Number 454 NT 625020 REG.GUIDE 1.150 60'INNER 25%ofT 60'T B 1.12 GF ISI-t35 Rev.2 45'NRI Exam iVumber 45o NT ViRI 625020 REG.GUIDE 1.150 600 T iVRI OUTER 75%ofT 60'T iVRI NRI~NO RECORDABLE LIDICATIOiiS C COSIPLETE EXAht R~RESTRICTED EXAiht T" TRAVKLUIG INDICATION PERREG GUIDE I.ISO irr>>NoiVTRAYKLING LNDICATION PER REG GUIDE I.I$0 susOUEIIANNA sTEAhl KLKcrnlc sTATtoN UNIT I RP Y INSKR VICE EXASILVATION EIGHTH REPUKLING AND INSPKCI1ON OUTAGE REPORT OP KXAhIUIATION RES UI TS SKCIION S CATEGORY B-A PRESSURE RETAINING WELDS IN REACTOR VESSEL WELD TYPE WELD ID ITEIV ivo.PROCEDURE REACI'OR VESSEL LOiVGITUDINAL BB Exam iVumber B 1.12 GF ISI-t35 Rev.2 04 IVY R$50 R 60'iVRI Com posite AutoManual Examination coverage was iVIu 100%.iVRI 625021 ASi>IE XI EÃAiV Rev.2 04 IViH 60'B B 1.12 GE-ISI-t35 Rev.2 iVUT-6 Rev.2 45o T Exam iVumber 45~VT ViRI 625021 REG.GUIDE 1.150 60~T PPilER 25%ofT 60'T BB B 1.12 GE-ISI-135 Rev.2 VIIT-6 Rev.2 45'iVRI Exam iV umber 45 VT 625021 REG.GUIDE 1.150 600 T OUTER 25%o(T 604 VT iVRI NRI~NO RECORDABLE INDICATIONS C~COSIPLETE KXAihl R~RESTRICTED EXAht T~TRAVELING INDICATION PERREG GUIDE I ISO NiT~NOiiAYKLING INDICATION PER REG GUIDE I~ISO susOUEIIANNA sTEAnt ELEGTRlc sTATIoix UNrr I RPv tNSERYICE ENAMINATION EICIITII REFUELCIC*ND INSPECTION OUTAGE REPORT OP EXAinnNATION RESULTS SECflON S CATEGORY B-A PRESSURE RETAINING WELDS IN REACTOR VESSEL IIELD TFPE/UELD ID ITEIll r'Vo.PROCEDURE EXrIM 1YPE REACTOR VESSEL LONGITUDINAI BC B 1.12 GE-ISI I35 Rev.2 O'M R 45'iVRI Composite Auto(manual Examination coverage was NRI 100%.Exam iVumber 6Q'NRI 625022 ASiME XI EXAM Rev.2 Qo WM 450 60'VRI iVRI BC B 1.12 GE-ISI I35 (VTT4 Revi 2 Rev.2 450 T iVRI Exam ilumber 45o NT iVRI 625022 REG.GUIDE 1.150 INVIER 25%ofT 6Q'60'T NRI ViRI BC B 1.12 GF ISI I35 Rev.2 (VUT4 Rev.2 45o T i lRI Exam i lumber 45'NT ilRI 625022 REG.GUIDE 1.150 60o T iVRI OUTER 75%ofT 60'NT iVRI NRI~NO RECORDABLE INDICATIONS C~COSIPLETE ENAnt R~RESTRIClED Exhnt T-TRAVELINC INDICATION PER REC CUIDE I.IS((Nr NOiNTRAVELLNC INDICATION PER REC GUIDE I.(5((

SVSQUEHA~ii A STEAiVI ELECTRIC STATION UNiIT 1 RPV INSERVlCE EXAi~ATION EIGHTH REFUELING A~i PitSPECTION OUTAGE REPORT OF EXAiVIPifATION RESULTS EXAiMNATION CATEGORY B-D SUSQ UEIIANNA STEASI ELECIIUC STATION UNiIT I RPV LISERVICE EXAPNLIATION EICHTII REFUEUNC AND INSPECIION OUTAGE REPORT OF EXASIINATION RESULTS 5 CCIIOi I S CATEGORY B-D FULL PENETRATION WELDS OF iNOZZLEI R 450 R 60'iVRI iVRI iVRI 625027 ASiVIE XI E."IAM NUTS Rcv.2 OOWM R 454 R 60'This is a one-sided examination.

iVozzle conllguration limits the accessible portion of the weld to 61.7%of the DVB-2500-7(b) volume.NOZZLE INSIDE RADIUS SECTION Exam Number 625024 B3.100 GE-ISI-ill Rev.2 ZONE 1 ZONE 2A iVRI The inside radius exam was 100%of the Code requirement iNRI iVIA B 3.90 GE-ISI-t35 iVUTA Rev, 2 Rev.2 45'iVRI Exam iVumber 45'T 625027 REG.GUIDE 1.150 60'iNRI INNER 25%ofT 604 NT iVRI illA B 3.90 GE-ISI t35 Rev.2 iVUTQ Rev.2 45'iVRI Exam iVumber 454 NT iVRI 625027 REG.GUIDE 1.150 604 T iVRI OUTER 75%ofT 60'T iVRI NRI iiO RECORDABLE INDICATIONS C~COMPLEIE EXASI R~RESTRICTED EXASI T~TRAVELING INDICATION PER REC CUIDE I.iso irf NOiAlLiVELINC INDICATION PER REG CUIDE I~ISO SUSQUEHANNA STEAM ELECTRICSTATION UNIT I RPY INSERYICE EXASILNATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAhHNATION RESULTS SECTION S CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS WELD TYPE WEI.D ID ITEIM IVO.PROCEDURE EXrhV TYPE iVOZZLE TO VESSEL WELD Exam iVumber 625028 ASME XI EXAM B 380 GE-ISI I35 Rev.2 O'M R 450 R 600 R O'M iV/A 45'V/A 60'V/A iVRI iVRI Viii This is a one-sided examination.

iVozzle configuration limits the accessible portion of the weld to 65.6%of the IWB-2500-7(b) volume.iVOZZLE INSIDE RADIUS SECITON Exam iVumber 625025 B3.100 GE-ISI-tll Rcv.2 ZONE I ZONE 2A iVRI The inside radius exam was 100%ol'the Code requirement Viii iV2A B 3.90 GE-ISI-t35 Rev.2 50T iVRI Exam iVumber 45'NT 625028 REG.GUIDE 1.150 600 T INNER 25%ol'T 60'T B 380 GE-ISI-t35 Rev.2 454 T Exam iVumber 454 NT 625028 REG.GUIDE 1.150 60'Viii OUTER 75%ofT 60'VT NRI>>iNO RECORDABLE DIDICATIOiNS C" COSIPLETE EXAM R>>RESTRICTED FYAM TRAYELING INDICATION PER REG GUIDE I IS0 NT NONTRAYELING HIDICATION PER REG GUIDE I.I$0 SUSQUEHANNA STEAM ELECTRIC STATION 0;IIT I RPV QisKRVICE EXAMINATION KIGIITH REFUELING AND INSPECTION OUTAGE REPORT OF KXASIINATION RESULTS SKCTIOit S CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS 0 EI.D TFPE 0'EI.D ID ITEM iVo.PROCEDURE i iOZZLE TO VESSEL WELD iV2F Exam Number 625029 ASiME XI EXAM B 3.90 GE-ISI-l35 Rcv.2 O'M R 450 R 600 R NRI IVRI iVM This is a one-sided examinadon.

iVozzle configuration limits the accessible portion of the weld to 65 4%of the IWB-2500-7(b) volume.i lOZZLE INSIDE RADIUS SECTION Exam iVumber 625026 B3.100 GE-ISI-l11 Rev.2 ZONE 1 ZOi lE 2A iVIu Thc inside radius exam was 100%of the Code requirement iVRI N2F B 3.90 GE-ISI t35 Rev.2 45o T iVRI Exam Number 45'NT 625029 REG.GUIDE 1.150 60'INNER 25%ofT 60'T NRI iV2F B 3.90 GE-ISI t35 Rev.2 45o T NRI Exam ilumber 45'NT iVRI 625029 REG.GUIDE 1.150 60'iVRI OUTER 75%ofT 60'VT iVRI NRI~NO RECORDABLE INDICATIONS C COMPLETE EXAM R RESTRICTED EXA~I T TRAVELING INDICATION PER REG GVIDE I.ISO ONTRAVELING IiIDICATION PER REG GVIDE I ISO SUSQUEHANNA STEAM EI ECIRIC STATION UNIT I RP V IN SERVICE EXAMINATION EIGHTH REFUELLNG AND tNSPECTION OUTAGE REPORT OF EXASHNATIO'I RESULTS szcrloN 5 CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS O'ELD T1'PE 8IELD ID ITEM ii/o.PROCEDURE EXAM T1'PE iVOZZLE TO VESSEL WELD N4A Exam iVumber 625030 ASiVIE XI EIAiV 8 3.90 GE-ISI-I35 Rev.2 iVUT<Rcv.2 O'iH R 45o R 60o R iVRI iVtu i lRI This is a one-sided examination.

Nozzle configuration limits the accessible portion of the weld to 62.0%of the IWB-2500-7(b) volume.iVOZZLE INSIDE RADIUS SECHON Exam iVumber iV/A 83.100 GE-ISI t1 1 Rev.2 iV/A V/A iV4A 8 3.90 GE-ISI I35 iVTT-6 Rev.2 Rev.2 45o T Exam., iVumber 45'T 4 Spot indications, acceptable.

625030 REG.GUIDE 1.150 60'VIRI INNER 25%ofT 60'T iVRI N4A 8 3.90 GE-ISI-t35 Rev.2 NUTS Rev.2 45O T iVRI Exam iVumber 45'T 625030 REG.GUIDE 1.150 60'iVRI OUTER 75%ofT 60'T iVRI NRI~NO RECORDABLE INDICATIONS C~COSIPLETE EXASI R~RESTRICTED EXAM TRAVELL(G INDICATION PER REC GUIDE I.I50 Nr~NONTRAVELING INDICATION PER REC CUID 8 I.I 50 SUSQ UEIIAiliNA STEASI ELECTRIC STATION UNIT I RPV DISERVICE EXASGYATION EIGIITII REFUELDIG AND QISPECtION OUTAGE REPORT OF EXANINATION RESULTS SECTION S CATEGORY B-D FULI PEttETRATION WELDS OF NfOZZLES IN VESSELS 0/ELD TFPE IPELD ID ITEM Po.PROCEDURE EX%V TFPE REI ARK'S iVOZZLE TO VESSEL WELD N48 Exam iVumber 625031 ASME XI EXAM 8 3.90 GE-ISI t35 Rev.2 ViUTC Rcv.2 O'WM R 450 R 60'iVRI iVRI NRI This is a one-sided examination.

iVozzle conBIguration limits the accessible portion of the weld to 65.6%of the IWB-2500-7(b) volume.NOZZLE INSIDE RADIUS SECTION Exam Number Vi/A 83.100 GF ISI t1 I Rev.2 ii/A iV/A N48 8 3.90 GF ISI-I35 Rev.2 45o T iVRI Exam i lumber iVUT-6 Rev.2 454 NT iVRI 625031 REG.GUIDE 1.150 60'INiVER 25%ofT 60'NT iV48 8 3.90 GE-ISI-i35 Rev.2 i IUD Rev.2 450 T NRI Exam Number 454 NT 625031 REG.GUIDE 1.150 600 T NRI OUTER 75%ofT 60'T NRI>>NO RECORDABLE INDICATIONS C>>COP4PLETE EXA,it R>>RESTRICTED ENAM T>>TRAVELING INDICATtON PER REG GUIDE I.IS0 NT>>iNONTRA VELING INDICATIOi I PER REG GUIDE I.ISO SUAVE!IANNA STEAM ELECTRIC STrtTI ON UNIT I RP V INSKRVICE EXAMINATIO'I KIGIITII REFUELING AND INSPECTION OUTACE REPORTOFKXAML'IATIONRESULTS SKCTIOil 0 CATEGORY B-D FULL PE(IETRATION WELDS OF NOZZLES IN VESSELS WELD TFPE WELD ID ITEM iYo.PROCEDURE NOZZLE TO VESSEL IVELD iV4C Exam iVumber 625032 ASiVE XI E'IAi>I B 3.90 GF ISI t35 Rev.2 04%i'll R 450 R 60'NRI NRI iVRI This is a one-sided examination.

Nonte configuration limits the accessible portion of the weld to 649%oi'he AVB-2500-7(b) volume.i iOZZLE INSIDE RADIUS SECTION Exam iVumber iV/A B3.100 GF ISl-tl1 Rcv.2 iV/A iV/A N4C B 3.90 GE-ISI-t35 Rev.2 45O T NRI Exam Viumber 625032 45'T li REG.GUIDE 1.150 60'INNER 25%ofT 60'T N4C B 3.90 GE-ISI t35 Rev.2 450 T iVM Exam iVumber 454 iNT 625032 REG.GUIDE 1.150 60'iVRI OUTER 75%ofT 60'NT iVRI NRI~NO RECORDABLE INDICATIONS C~COSIPLETE EXAilt R RESTRICTED EXAial T~TRA VKLDIG DID ICATION PER REC C VIDE I.ISO itT" NONTRAVKLING LNDICATIOil PER RKG GUIDE I.I$0 SUSQUEIIANNA STEAM ELECTRIC STATIOaaI UNIT I RP V INSERVICE EXAamNATION EIGHTII REPUELDIG AND INSPECTION OUTAGE REPORT OP EXAbIDIATION RESULTS sEcrloN 5 CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES W VESSELS WELD 1TPE WELD ID ITEM IY0.PROCEDURE EXAM TFPE iVOZZLE TO VESSEL WELD N4D Exam aVumber 625033 ASaVE XI EXAiV B 3.90 GE-ISI I35 iVUTA Rev.2 Rcv.2 O'i>I R 45'600 R i iRI iNRI aVull This is a one-sided examination.

iVozzle conliguration limits the accessible portion of the weld to 63.0%of the IWB>>2500-7(b) volume.iVOZZLE INSIDE RADIUS SECTION Exam iVumber iV/A B3.100 GE-ISI-tl 1 Rcv.2 iVIA iV/A iV4D B 380 GE-ISI 535 Rev.2 i LUTE Rev.2 45>>T Exam iVum her 45'T iNRI 625033 REG.GUIDE 1.150 60'INNER 25%ofT 60'NT aV4D B 3.90 GE-ISI t35 aVUTA Rev.2 Rev.2 45'iVRI Exam aVumber 45'NT iVRI 625033 REG.GUIDE 1.150 600 T VaRI OUTER 75%ofT 604 iVT iVRI NRI" iNO RECORDABLE LNDICATIONS C>>COMPLETE ETAM R>>RESTRICTED EXAM T>>TRAVELCaG DID ICATION PER REG GUIDE l.l 50 aVP>>NONTRAVELDIG INDICATION PER REG GUIDE I.I 50 SUSQUEHAiNNA STEAM ELECTRIC STATION UNIT I RPV INSERVICE EXAhQNATION EIGHTH REFUELING AND INSPECTIOil OUTAGE REPORT OF EXAhHNATION RESULTS 5ECIION 5 CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS IVELD TYPE/VELD ID ITEM IY0.PROCEDURE i iOZZLE TO VESSEL WELD iV4E Exam iVumber 625034 ASME XI EXAM B 3.90 GE-ISI-t35 Rcv.2 Oo WM R 454 R 60'iVRI ViRI IVRI This is a one-sided examination.

Nonle conliguration limits the accessible portion of the weld to 65.6%of the IWB-2500-7(b) volume.i NOZZLE INSIDE RADIUS SECTION Exam iiumbcr it/A B3.100 GE-ISI-ill Rcv.2 iV/A iV/A N4E B 3.90 GE-ISI-l35 Rev.2 45'Exam iVumber 45'T 2 Spot indications, acceptable.

625034 REG.GUIDE 1.150 60'NRI INNER 25%ofT 60'T 4 Spot indications, acceptable.

N4E B 3.90 GE-ISI I35 Rev.2 45 T Exam Number 45'T 625034 REG.GUIDE 1.150 60'OUTER 75%ofT 604 NT iVRI NRI>>NO RECORDABLE

!NDICATIONS C>>COMPLETE EXAM R RESTRICTED EXA,'it T>>TRAVEUNG INDICATION PER REG GUIDE I.!50 iNT>>NOIITRAVELING INDICATION PER REG GUIDE I.I50 SUSQUEIIANNA STEAht ELECTRIC STATION UNIT I RPV INSERVICE EXASILYATION EICIITII REFUELL'IG AND INSPECTION OUTAGE REPORT OF EXASIINATIONRESULTS SECTIOÃS CATEGORY B-D FULL PEttETRATION FIELDS OF NOZZLES IN VESSELS lVELD TFPE 8'ELD ID ITEM iVo.PROCEDURE REIllAEJKS'VOZZLE TO VESSEL iVELD Vi4F Exam Number 625035 ASiME XI EXAiM B 3.90 GE-ISI t35 Rev.2 0'VM R 45o R 60'iVRI iiI NRI This is a one-sided examination.

i lozzle contiguration limits the accessible portion of the weld to 65.6%of the DVB-2500-7(b) volume.NOZZLE INSIDE RADIUS SECTION Exam Viumber Vi/A B3.100 GE-ISI-l11 Rev.2 iV/A iV/A iV4F B 3.90 GE-ISI-t35 Rcv.2 45O T i lRI Exam Number 45'T NRI 625035 REG.GUIDE 1.150 60'INNER 25%ofT 604 NT N4F B 3.90 GE-ISI-t35 Rev.2 45'NRI'xam iVum her 45O NT iVRI 625035 REG.GUIDE 1.150 60'iVRI OUTER 75%ofT 60'NT ilRI iNRI~NO RECORDABLE INDtCATIONS C COSIPLETE ENAht R~RESTRICTED EXAht T~TRAVELDIC INDICATIOit PER REG CUIDE I.ISO i IT>>NONTRAVELLNC INDICATION PER REG CUIDE I~ISO

, SUSQUEHANNA STEAiVI ELECTRIC STATION UNIT 1 RPV PfSERVICE EXAiVIINATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAiVKWATION RESULTS EXAl'dINATION CATEGORY B-G-2 SUSQUEHANNA STEAM ELECTRIC STATION UNIT I RP V INS ERVICE EXAMINATION EIGHTII REP UELL'IG AND LYSPECIMN OUTAGE REPORT Of ETASILYATION RESULTS SECTION S CATEGORY B-G-2 PRESSURE RETAINING BOLTING, 2 Ii L AÃ3 LESS Pit DIAiVKTER COMPOIVE>V T TFPE COMP.ID ITEM I'VO.PROCEDURE EXAM TYPE CRD HOUSING BOLTS, STUDS, AND iiS CRD HOUSING BOLTS, STUDS, AND ASS CRD HOUSING BOLTS, STUDS, AND iiS CRD HOUSING BOLTS STUDS, AND i fUTS CRD HOUSING BOLTS, STUDS, AiVD i iUTS CRD HOUSING BOLTS, STUDS, Ai fD ASS CRD HOUSING BOLTS, STUDS, AND i 1UTS CRD HOUSING BOLTS STUDS, AND i IUTS CRD HOUSING BOLTS, STUDS, AND NUTS CRD HOUSING BOLTS, STUDS, AND iNUTS CRD 10-31 EXAM No.555005 CRD 10-I3 EXAM i fo.555006 CRD 14-27 EXAM No.555007 CRD 14-31 EXAiM iNo.555008 CRD 1445 EXAiM No.555009 CRD 18-13 EXAM iNo.555010 CRD 18-59 EXAilI iNo.555011 CRD 26-27 EXAM No.555012 CRD 3043 EXAilI No.555013 CRD 30-43 EXAiM No.555014 , B7.80 B 7.80 iiT-I B 730 iVTT-I B 7.80 i Pfl'-I B 7.80~i-I B 7.80 iVTT-I B 7.80 i~-I B 7.80 i IVT-I B 7.80 B 7.80 iiT-I Rev.I Rcv.I Rev.I Rev.1 Rcv.1 Rev.I Rcv.I Rev.I Rev.I Rev.I VT-I VT-I VT-I VT-I VT-I VT-1 VT-I VT-I VT-I VT-I ACCEPTABLE REPLACED WITH NEW DESIGN BOLTS REJECTABLE REPLACED WITH NEW DESIGN BOLTS REJECTABLE REPLACED WITH NEW DESIGiN BOLTS REJ ECI'ABLE REPLACED WITH iVEW DESIGiN BOLTS REJECTABLE REPLACED WITH NEW DESIGN BOLTS ACCEPTABLE REPLACED WITH NEW DESIGiN BOLTS ACCEPTABLE REPLACED WITH iVEW DESIGN BOLTS ACCEPTABLE REPLACED WITH NEW DESIGN BOLTS ACCEPTABLE REPLACED WITH NEW DESIGiN BOLTS ACCEPTABLE REPLACED WITH iVEW DESIGiV BOLTS NRI SUSQUEIIANNA STEAil ELECTRIC STATION UNIT I RPV INSERVICE ENA>ILTATION EIGBTII REPUELDIG AND&SPECIION OUTAGE REPORT OP E.'fAhUNATIONRESULTS SECTION I CATEGORY B-G-2 PRESSURE RETAICiifG BOLTING, 2 IN.Ai&3 LESS IN DIAiVIETER COMPONEI'YT TYPE COMP.ID ITEM IYo.PROCEDURE EXriM TYPE REMARKS CRD HOUSING BOLTS, STUDS)AiVD iVUSS CRD HOUSING BOLTS, STUDS, AND iVUTS CRD HOUSING BOLTS, STUDS, i')iVSS CRD HOUSING BOLTS, STUDS, AND iVUTS CRD HOUSPIG BOLTS, STUDS, AND iVUTS CRD HOUSING BOLTS, STUDS, AND i lUTS CRD HOUSING BOLTS, STUDS, AND i lUTS CRD HOUSING BOLTS, SPUDS)AiVD iVUTS CRD 34-59 EXAiif i lo.555015 CRD 38-15 EXAM No.555016 CRD 38-59 EXAiH No.555011 CRD 42-11 EXAiif i lo.555018 CRD 4647 EXAiX iVo.555019 CRD 46-19 EXAIX No.555020 CRD 50-19 EXAi>f iVo.555021 CRD 50-17 EXAi>f No.555022 B 780 iVVT-I B 7.80 i lVT-I B 7.SO)VTT I B 7.SO iVVT.I B 7.SO)VENT-I B 1.SO iVVT-I B 7.SO iVTT I B 7.80 iVTT-I Rev.I Rev.I Rev.I Rev.I Rev.I Rev.I Rcv.I Rcv.I VT-1 VT-I VT-I VT-I VT-I VT-I VT-I VT-1 REJECI'ABLE REPLACED WITH iVELV DESIG)V BOLTS REJ ECTABLE REPLACED WITH NEW DESIG)V BOLTS REJECTABLE REPLACED WITH V)EW DESIG)V BOLTS REJECTABLE REPLACED WITH I fEW DESIGVi BOLTS ACCEPTABLE REPLACED WITH iVEW DESIGV)BOLTS ACCEPTABLE REPLACED WITH ViEW DESIGN BOLTS ACCEPTABLE REPLACED WITH i fEW DESIGN BOLTS ACCEPTABLE REPLACED WITH iVEW DESIG.l BOLTS CRD HOUSING BOLTS, STUDS, Ai lD iVUTS CRD 54-15 EXA)if iVo.555023 B 7.80 iVTT-I Rev.I VT-I VT-I REJECTABLE REPLACED WITH NEW DESIGV BOI.TS CRD HOUSNiG BOLTS, STUDS, AND iVUTS CRD 54-19 EXAiif Vio.555024 B 7Jl0)VS-I Rev.I REPLACED WITH i lEW DESIG)BOLTS NRI~NO RECORDABLE DIDICATIONS SUSQUEHAi tNA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiMNATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EK4VIP/ATION RESULTS EXAMINATION CATEGORY 3-J SUSQUEHANNA STEANI ELECTRIC STATION UNIT I RPV IiNSERVICE E',GLiIDIATION EICIITII REP UELINC AND LNSPECIION OUTAGE REPORT Of ENASILIATION RESULTS SECTION CATEGORY B-J PRESSURE RETAKING WKLDS IN PIPING JVELD TYPE HELD ID ITEM iYo.PROCEDURE CIRCUilIFEREiiAL WELD i lOZZLE TO SAFE END N4A EXAM ilo.625052 B9.11 N~iD-I Rev.8 CIRC ViMFERENTIAL WELD NOZZLE TO SAFE END N4B EXAM i lo.625053 B9.11 Ni>ITWD-I Rcv.8 SVR CIRCUMFERENTIAL WELD N4C B9.11 NiIITWD-I Rev.S NRI NOZZLE TO SAFE EiiD EXAM No.625054 CIRCViNFEREiVAAL WELD i lOZZLE TO SAFE Ei lD il4D EXAM iNo.625055 B9.11 Ni>CAVD-I Rcv.8 i lRI C CIRCUM FEREiiAL WELD iNOZZLE TO SAFE END iN4E EXAM i lo.625056 B9.11 NilITWD-I Rev.8 SUR iNRI iNRI~NO RECORDADLE Ci'DICATIONS SUSQUEIIANNA STEAM ELECTRIC STATION UNIT I RPV LVSERVICE MASIPNATIOiv EIGIITII REFUELING AND INSPECIION OUTAGE REPORT OF ENAbILIATION RESULTS SECTION 3 CATEGORY B-J PRESSURE RETAINING WELDS IN PIP&fG JVELD TYPE fPELD ID ITEM IVO.PROCEDURE CIRCUilfFERENTIAL WELD iV4F B9.11 iVKAVD-I Rev.8 SUR iVRI i NOZZLE TO SAFE EiVD EXAM i lo.625057 iNRI~NO RECORDASLE DIDICATIONS SUSQUEHANNA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVQNATION EIGHTH REFUELING Ai 6)INSPECTION OUTAGE REPORT OF EXAiVGNATION RESULTS EXAMINATION CATEGORY AUG-2 SUSQUEIIANNA STEAP4 EI.ECfRIC STAT'ION UNIT I RP Y INSER VICE E.'IASIINATION EICIITII REFUELUIC AND LNSPECTION OUTAGE REPORT OF ENAPafNATION RESULTS SECTION S CATEGORY AUG-2 AUGMENTED EXAIVGNATIONS PER NUREG-0313

/VELD TYPE/VELD ID 1TEM'ROCEDURE iYo.EYrhM TYPE i NOZZLE TO SAFE EiVD i iIB-iVOZ-SE EXAII No.625036 AUG-2 GE-ISI t40 Rev.I VOL Post i%SIP iVRI iVon relevant indicahons, such as ID Geometry, Interface, Root, ctc., werc recorded.iVOZZLE TO SAFE EiVD iV28-iVOZ SE EXAM!iVo.625037 AUG-2 GE-ISI-t40 Rev.1 VOL Post MSIP iVRI iVon relevant indications, such as ID Geometry, Interface, Root, etc., were recorded.iiOZZLE TO SAFE EiVD iV2C-ViOZ SE E fAhI iVo.625038 AUG-2 GE-ISI-l40 Rev.1 VOL Post bISIP iVRI iVon relevant indications, such as ID Geometry, Interface, Root, etc., were recorded.i NOZZLE TO SAFE E~i iV2D-iVOZ-SE EXAiM iVo.625039 AUG-2 GE-ISI t40 Rev.1 VOL Post MSIP iVRI iVon relevant indications, such as ID Geometry, Interface, Root, etc were recorded.iVOZZLE TO SAFE EiVD iV2E~VOZ SE EXAilI iVo.625040 AUG-2 GE-ISI-t40 Rev.I VOL Post i%SIP iVRI i ion relevant indications, such as ID Geometry, Interlace, Root, etc., were recorded.iVOZZLE TO SAFE EiVD iV2G-iVOZ-SE EXAihI iVo.625041 AUG-2 GE-ISI-t40 Rev.1 VOL Post AISIP iVRI iVon relevant indications, such as ID Geometry, Interface, Root, etc., werc recorded.NiRI NiO RELEYAivr ENDICATIONS SUSQLVIIARNA STEAS'I ELECTRIC STATIO,'I IEiIT I RPV UISKRVICE ETASILIATIO!I EIGHTH REf UELLIG AIID INSPECTIOV OUTAGE REPORT Of EEADIUIATIOi I RESULTS SECTIO!I S CATEGORY AVG-2 AVGMEINTED EXAiVlPlATIONS PER iiVREG-0313 WELD TFPE WELD ID ITEM IY0.PROCEDURE EX4Vl 7YPE iVOZZLE TO SAFE END N2H>>lOZ-SE EXAiM Vio.625042 AUG-2 GF ISI-I40 Rev.I VOL Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, etc., were recorded.iVOZZLE TO SAFE Ei lD iV2J-iVOZ-SE EXAM No.625043 AUG-2 GE-ISI-t40 Rev.I VOL Post i>ISIP Non relevant indications, such as ID Geometry, Interface, Root, etc werc recorded.iVOZZLE TO SAFE EiVD iV5A~VOZ-SE EXAM No.625044 AUG-2 GE-ISI-i40 Rcv.I Rev.4 VOL Post i>ISIP Non relevant Indications, such as ID Geometry, Interface, Root, ctcwere recorded.Ezam limited to 939%SAFE EiVD EXT TO SAFE END i l5AOE EXT4E AUG-2 GE-ISI t40 Rev.I VOL EXAM No.625045 iVUT-I Rev.4 Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, ctc., were recorded.iVOZZLE TO SAFE EiVD i l58-iVOZ SE EXAM No.625046 AUG-2 ViTT-I Rev.4 VOL Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, etcwere recorded.SAFE EiVD EXTTO SAFE EiVD Vi584E EX'.EXAilI Vio.625047 AUG-2 iVUT-I Rev.4 VOL Post iISIP Non relevant indications, such as ID Geometry, Interface, Root,<<tc., were recorded.:IRI~NO RELEVAiiT BDICATIORS SUSQUEHANNA STEAbl KLECTRIC STATION UNIT I RPV INSERVICE EXA51LIATION EIGHTII REFUELUIG AND INSPECTION OUTAGE REPORT OP KXASILIATION RESULTS SKCTION S CATEGORY AVG-2 A VGiVEENTED EXAIVGNATIONS PER t lUREG-0313 JYELD?TEE fYELD ID ITEM lvo.PROCEDURE EXAM TFPE REMARKS iVOZZLE TO SAFE EVD i l8A-iVOZ-SE EXAM iVo.625048 AUG-2 i lUT-I Rcv.4 VOL Post MSIP iVRI iVon relevant indications, such as ID Geometry, Interface, Rooh etc., were recorded.SAFE END TO PENT SEAL iV8AOE-PENT SEAL EXAM iVo.625049 AUG-2 iVUT-I Rev.4 VOL Post MSIP iVRI iVon relevant Indications, such as ID Geometry, Interface, Root, etc., were fecordcdi iVOZZLE TO SAFE END i i8B~VOZ-SE EXAM No.625050 AUG-2 iVTT-I Rcv.4 VOL Post MSIP iVon relevant indications, such as ID Geometry, Interface, Root, ctc., were recorded.SAFE END TO PENT SEAL N8M-PENT SEAL EXAM iVo.625051 AUG-2 iVUT-I Rev 4 VOL Post MSIP iVRI Non relevant indications, such as ID Geometry, Interface, Root, etc., were recorded.iNRI NO RELEVANT tNDICATIOiVS I

SUSQUEE54%t fA STEAiVl ELECTRIC STATION UNIT 1 RPV INSERVICE EXAi~ATION EIGHTH REFUELING W fD INSPECTION OUTAGE REPORT OF EXAiVlPifATION RESULTS EKQVQNATION CATEGORY AUG-3 SUSQUEHANNA STEASI ELECTRIC STATION UiNIT I RPV LISERVICEEXASIINATION EIGHTH REFUELING AND LNSPECTION OUTAGE REPORT OF EXASILtATION RESULTS SECTION CATEGORY AUG-3 AUGiiEENTED EXAIVGNATIONS PER NUREG-0619 WELD T1'PE WELD ID ITEDf IVO.PROCEDURE EXON ZYPE NOZZLE INSIDE RADIUS N4A-IR EXAM No.625001 AUG-3 GE-ISI-t1 I Rcv.2 VOL GE-ISI-t44 Rev.I NRI Examination was limited to 96.2%due to the proximity of Nozzie NIIA.NOZZLE TO SAFE END N4A-VLOZ-SE AUGH GE-ISI t38 Rcv.I VOL EXAM No.625002 NUT-2 Rev.3 Nion relevant indications, such as ID Geometry, Interface.

Root, etcwere recorded.Examined 100%i iOZZLE BORE V14A-BORE EXAM iVo.625003 AUG'E-ISI III Rev.2 VOL GE-ISI-i44 Rev.I NRI Examined 100%NIOZZLE INSIDE RADIUS N4B-IR AUG'E-ISI-ill Rev.I VOL iiRI EXAM No.624004 NOZZLE TO SAFE END N48'iOZ-SE EXAM No.624005 AU~GE-ISI-I39 Rev.0 VOL NRI Non relevant indications, such as ID Geometry, Interface, Root, ctc., were recordedi NOZZLE BORE iV4B-BORE EXAhl Vlo.624006 AUG-3 GE-ISI-II I Rev.I VOL GE-ISI444 Rcv.0 NRI Examination was limited to 98.0%due to thermocouple pads.NO RECORD*au LNDICATIONS STEASI ELECTRIC STATIOR BRIT I RPV LISERVICEEXAML'IATION EIGIITII REFUELING AIID INSPECIIOR OUTAGE REPORT OF EXAIiIINATI0Ã RESUI,TS SECTIOR S CATEGORY AUG-3 AUGMENTED EXAVGNATIONS PER NUREG-0619 IVELD TYPE/VELD ID ITEMS IVO.PROCEDURE EXrhM TYPE NOZZLE INSIDE RADIUS iV4C-IR EXAiM No.625007 AUGH GE-ISI-ill Rev.2 VOL GE-ISI-i44 Rev.I iVRI Examined 100%iVOZZLE TO SAFE EiVD N4C-iiOZ SE AU~GE-ISI t38 Rev.1 VOL i iRI EXAM No.625008 NUT-2 Rcv.3 Non relevant indications, such as ID Geometry, Interface, Root, ctc., were rccordcde Examined 100%i iOZZLE BORE N4C-BORE AUG-3 GF ISI ill Rev.2 VOL GF ISI-i44 Rev.1 i iRI Examined 100%EXAM No.625009 i iOZZLE INSIDE RADIUS i i4D-IR AUG'E-ISI-i11 Rev.2 VOL EXAM No.625010 GE-ISI-i44 Rev.1 Examination was limited to 96.2%due to the proximity of Nozzle NIIB.iVOZZLE TO SAFE EiVD iV4D-ViO?SE EXAi>I i io.625011 AUGH GE-ISI-i38 Rev.1 VOL i iUT-2 Rev.3 iVon rclcvant indications, such as ID Geometry, Interface, Root,<<tc., wer>>recorded.Examined 100%iVOZZLE BORE i 4D-BORE EXAilI Vio.625012 AUGH GE-ISI-tl1 Rev.1 VOL GE-ISI t44 Rev.0 i iRI Examination was limited to 96.7%due to thermocouple pads.ntu~RO RECORDABLE 1NDICATIOBS

'USQUEHANNA STEA,'it ELECTRIC STATION UNIT I RP V INSERVICEEXASIDIA TIP N EIGIITH REFUELING AND INSPECIION OUTAGE REPORT OF EXASIINATION RESULTS SECTION S CATEGORY AUG-3 AUGMENTED EXAIVGNATIONS PER NUREG-0619 WELD TFPE WELD ID ITEM IY0.PROCED URE NOZZLE INSIDE RADIUS i i4E-IR EXAM No.625013 AUG-3 GE-ISI-$11 Rev.2 VOL GE-ISI-i44 Rev.I i iRI Examined 100%i iOZZLE TO SAFE~i N4E~IOZ-SE EXAM No.625014 AUG-3 GE-ISI t38 Rev.I VOL i fUT-2 Rev.3 Non relevant indications, such as ID Geometry, Interface.

Root, etc., were recorded.Examined 100%i iOZZLE BORE iV4E-BORE AUG-3 GE-ISI-t1 I Rev.2 VOL EXAM No.625015 GE-ISI-i44 Rev.I Examined 100%iVOZZLE INSIDE RADIUS iV4F-IR AUG'E-ISI-ill Rev.2 VOL EXAM iVo.625016 GE-ISI-I44 Rev.1 Examined 100%iVOZZLE TO SAFE ENiD N4F-iVOZ-SE EXAiVI i io.625017 AUG'E-ISI-i38 NUT-2 Rev.I VOL Rev.3 i'ion relevant indications, such as ID Geometry, Interface, Root, etcwere recorded.Examined 100%i iOZZLE BORE i i4F-BORE EXAM iVo.625018 AUG-3 GE-ISI-t11 Rev.1 VOL GE-ISI t44 Rcv.0 iVRI Examined 100%iNRI~NO RECORDABLE LNDICATIONS SUSQUEHANNA STEAiVl ELECTRIC STATION UiilT 1 RPV INSERVICE EXAVQNATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EXAiVGNATION RESULTS SECTION IV

SUMMARY

REPORTS SUSQUEHAi WA STEAiYl ELECTRIC STATION UNiIT 1 RPV INSERVICE EXAiVONATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAiMNATION RESULTS

SUMMARY

REPORT"1 Summary Report Number 1: USNRC REGULATORY GUIDE 1.150 REPORT OF EXAMINATION RESULTS FOR THE SUSQUEHANNA UNIT 1, EIGHTH INSERVICE EXAMINATION.

USNRC Regulatory Guide 1.150, Revision I, Alternate Method requires that ultrasonic examinations performed on reactor pressure vessels be documented in a manner that will allow meaningful comparison of data gathered during successive examinations.

This report documents the steps taken by General Electric to assure that the data gathered during the Susquehanna Unit 1 Inservice Ultrasonic Examination meets the intent of Reg.Guide 1.150.Ultrasonic Examinations during the Susquehanna Unit 1, Eighth Refueling Outage, were performed using both automated and manual examination equipment.

This report addresses each section of Reg.Guide 1.150 as it affects both types of examination equipment.

Data gathered supporting the conclusions presented in this report is on file at the site.The results of each examination are reported along with the required evaluations.

The examination data is on file at the site.Procedure GE-ADM-1006, defines the Reg.Guide 1.150 compliance activities performed by General Electric during the Susquehanna Unit I Inservice Examination.

This report contains the documentation required by the procedure.

The examination was performed in accordance with the requirements of ASiVlE Section XI 1989 Edition, without Addenda;supplemented by GE-ADM-1006.

INSPECTION SYSTEM PERFORMANCE CHECKS The Pre-Exam Performance Checks specified in Paragraph 1.1 of the Reg.Guide Alternate Method were not performed during the Susquehanna Unit I Inservice Examination.

General Electric's Quality Assurance requirements do not allow performance checks performed up to six months in advance of an examination to constitute Quality Assurance records for the project.These checks, if performed, could not become a part of the records package.The Field Performance Checks specified in Para~mph 1.2 of the Reg.Guide Alternate Method are performed for both automated and manual ultrasonic examination equipment.

The required checks are performed as follows: Field Performance Checks W The required RF wave form and&equency amplitude information, for the search units used during the automated examinations, are generated via an FFT transform through the examination system.The system then generates a Data Sheet.The frequency amplitude, band width and associated data appear on the print out.The data displays a digitized RF wave form and all information necessary for re-creating the equipment set-up.A specialized block, designed for obtaining the required data, was used.The reflectors are documented to allow comparisons at a later date.Each transducer was analyzed.RF wave form and frequency analysis information, for each search unit used during the automated exams, is on file at the site.These files contain information gathered before the exams were begun and after they were completed.

The required RF wave form and frequency amplitude information, for the search units used during manual examinations, are also gathered through the FFT transform function of the automated examination system.

The system generated Data Sheet is used.The frequency amplitude, band width and associated data appear on the print out.The data displays a digitized RF wave form and all information necessary for re-creating the equipment set-up.A specialized block, designed for obtaining the required data, was used.The reflectors are documented to allow comparisons at a later date.Each transducer is analyzed for a specific use, and with a specific wedge (shoe)where applicable.

RF wave form and frequency analysis information for each search unit used during the manual exams in on file at the site.Linearity data for both automated and manual examination systems is recorded as required by the applicable examination procedure.

The Procedures governing these ultrasonic examinations require documentation of these checks on a calibration data sheet.These calibration data sheets are not an attachment in this report.Linearity data is on file at the site.These files contain all required records.Beam profile information is obtained for each automated examination package and each manual examination transducer/wedge combination used during ultrasonic examination of RPV welds.The data for automated examination packages is gathered using an automated calibration scanning mechanism.

The data for manual examination search units is gathered using manual techniques.

The beam profile data is not an attachment to this report.Beam profile data is on file at the site.These files contain information gathered both before the exams were begun and after they were completed CALIBRATION Automated examination system calibrations were performed in accordance with procedure GE-ISI<35 Revision 2 for GERIS 2000 Examination of RPV Assembly Welds.The Initial Calibration of the examination system was performed dynamically using a mechanized calibration scanner that operates in a manner that duplicated the essential variables of the.mechanized examination scanner.This is immediately rechecked in a static mode to cotrelate the calibration simulator.

The Initial Recheck (static mode)is then used for subsequent calibrations.

The scanner speed set by the operator for the examination scanner was, per procedure, limited to the scanning speed set for the calibration scanner.The direction(s) of scanning during calibration trace (forward)and retrace (backward) are verified during the system calibration.

If, for example, a valid calibration is obtained for both trace and retrace modes, examination data may be gathered in both the forward and backward directions.

If a valid calibration for only one direction was obtained then examination data was gathered only in the direction of the valid calibration.

Records for the automated system calibrations are on file at the site.Calibrations for manual examination systems are performed in accordance with procedure NUT-6, Revision 2, for all Vessel Assembly Welds.This manual examination procedure uses static calibration methods.The signals are maximized during both calibration and examination.

Calibrations are verified at scanning speed.Records for manual system calibrations are on file at the site.There were two nonconformances issued against Geris 2000 calibrations.

Both involved exceeding the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> calibration period.In both cases, the data was found to be acceptable.

The nonconformance reports appear at the end of this report.

Calibration confirmations, for both automated and manual examination systems, are performed in accordance with the applicable examination procedure.

In all cases, the procedural requirements equal or exceed those specified in the ASlvEE Code.There were no electronic simulators or off-site system calibrations used during the Susquehanna Unit 1 Inservice Examination.

The calibration blocks used during the Susquehanna Unit 1 Inservice Examination are furnished by the Owner.These blocks were fabricated in accordance with the requirements of Appendix 1 of ASME Section XI, 1974 Edition, with addenda through Winter 1975.No alternate calibration blocks or new conventional blocks were used during this Inservice Examination.

There was an acoustic difference noted between two of the vessel calibration blocks.See report Number 3 for details.EXAMINATION The scope and extent of the examinations are as specified in the Susquehanna Unit 1 Inservice Inspection Plan.Minor interferences occurred during the examination, due to the RPV and insulation designs.The interferences were analyzed and their effect on the examination documented.

The examinations were performed in accordance with written procedures.

The procedures contain requirements for electronic gating and transducer scanning overlap.The procedural requirements are in accordance with Reg.Guide 1.150 requirements.

Internal surface flaw detection capability, for both automated and manual exam systems, is demonstrated by detection of the ASME 2%ID notch during calibration.

No alternate reflectors were utilized for this examination.

The referenced 1" of material measured perpendicular to the clad/base metal interface was examined.See the Recording and Sizing Section for details.W The ultrasonic examination techniques developed by General Electric for Inservice Inspections at Susquehanna Unit 1, utilize the ASME Section V, Article 4 specified beaming angles of 0', 45', and 60'.These beam angles are not based on Susquehanna specific weld preparation details.The ability of these beaming angles to detect unfavorably oriented planar flaws was demonstrated.

See the Recording and Sizing Section for details.The sizing error band, for both automated and manual examination equipment, is estimated below: Automated Examination Equipment Error Band+7.6%t ID Notches were consistently oversized.

These data are used during indication analysis.Manual Examination Equipment Error Band+8.8%t ID notch data was consistently oversized by the combination of beaming angles.

V The estimate of unexamined and not effectively examined volumes, for both automated and manual examinations, are shown below: I)Volume Affected by near field effects.Automated Examination Manual Examination

.500" beneath the scanning surface.500" beneath the scanning surface 2)Volume Shadowed by Laminar defects.Automated Examination None determinable, no indications with total loss of back reflection Manual Examination None determinable, no indications with total loss of back reflection 3)Volumes unexamined due to vessel configuration.

Vessel configuration resulted in some unexamined volume for both automated and manual examinations.

The"Examination Coverage Report" details the unexamined volumes and their effect on each examination.

4)Unexamined volumes near the cladded ID surface Automated Examination None determinable, artificial flaws at interface are detectable.

Manual Examination None determinable, artificial flaws at interface are detectable.

5)Volumes affected by electronic gating.Automated Examination None determinable, entire thickness was within the system gates.Manual Examination No electronic gating was used.Sketches of Automatic Examination Equipment for use by reviewers, are included with the Coverage Report.No sketches of manual examination equipment are included since the equipment consisted of standard catalogue items needing no such sketches to allow review.No alternate volumetric examinations were used during the Inservice Examination of Susquehanna Unit 1 Reactor Pressure Vessel Assembly Welds.

Nonconformance Report Project SUSQUEHAi DNA UNIT I Project No.I FRMD SSES I-Ool Reference Documents:

('Q f-W35+v~Description of Nonconformance: (State Cause)NCR Code 043 Cause Code<a Z, Due to mechanical failure the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> calibration period was exceeded by 59 minutes.Hugo S.%interhalter Initiated By as-'Wts ut-'dbate 4I04(95 QC Supervisor I 10CPR21 Review: ()Is (Vf Is Not Reportable Signature:

Date Proposed Disposition and Technical Justification: (Attach Extra Sheets, Sketches, Etc.as Necessary)

Accept-As-Is El Repair CI Rework Q'eject C3 Other If Not Mat.Or Items Q The mechanical failure was repaired and the calibration was checked successfully.

The elapsed time from cal in to cal out was 12:59.Project Manager J Date~~~QC Supervisor Date~~t'~Final D'sition Accept-As-Is

&Repair Dispositions, Design Verification Is Provided Per: Since the calibration was checked successfully the data was determined to be good.<<Client (~If Required)Project Manager Date~rr v*ANI Review Date r~QC Supervisor g gg-5's Date-Date~lZ-Preventative Action: v*I QC Approval Date~6'isposition Completed And Nonconformance Report Closed QC Supervisor

,~z~o~W Nonconformance Report SUSQUEHANiVA UiVIT I Reference Documents:

gQ-jSl-935'raq.~Project No.1 pRMD SSES 1-002 Description of Nonconformance: (State Cause)NCR Code agg Cause Code~p g Due to delays in being granted access to enter nozzle windows the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> calibration period was exceeded by 66 minutes.Hugo S.Winterhalter p Initiated By ate~9L95 QC Supervisor IOCFR21 Review: ()Is (+is Not Reportable Signature:

Date~ljoeS Proposed Disposition and Technical Justification: (Attach Extra Sheets, Sketches, Etc.as Necessary)

Accept-As-Is g Repair Rework CI Reject Other If Not Mat.Or Items O Access was obtained, the transducer package was retrieved and the calibration was checked successfully.

The elapsed time from cal in to cal out was 13:06.j/Project Manager Date i'C Supervisor Date KL Final Disposition ccept-As-I Zc Repair Dispositions, Design Verification Is Provided Per: Since the calibration was checked successfully, the data was determined to be good and no rescans were necessary.

<<Client (~If Required)Project Manager Preventative Action: Z~provc.~p'e->4b Dare~ri+'ANi Review Dare~~'~QC Supervisor Pla~n,~)D.te+-~~~'ate~4QC Approval Date Disposition Completed And Nonconformance Report Closed QC Supervisor Date SUSQUEHAi~iA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAMINATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EXAiVIINATION RESULTS

SUMMARY

REPORT P2

Summary RePort REPORT OF EXAMINATION COVERAGE Number 2: This report details the extent of examination coverage for each item examined, during the Susquehanna Unit I, Eighth Refueling and Inspection Outage.It identifies the areas where transducer access was limited due to RPV configuration, part geometry, insulation configuration, and/or configuration of the search unit.This report documents the interferences, provides a description of the measures taken to reduce their effect, and provides the percentage of the examination volume/area that was effectively examined.The following pages list the items examined, the examination technique used, identification of any interference(s), estimates of the volumes examined in accordance with ASME Section XI requirements, and estimates of the volumes not examined in accordance with Section XI requirements.

The details of any interference are documented in the Examination Data for the Item.

Susquehanna RF 4 IO 8 GERIS 2000 OD Examination Coverage Report Rev 0 Prepared by: Reviewed by: e g z.t Mark Torok Date: Wade F.Miller ee~M P~e Dare: 5/z 7/9M Description of the Nozzle Examination Techniques of GKRIS 2000 OD GE Nuclear Energy 175 Curtner Avenue San Jose, California 95125 January, 1995 I.INTRODUCTION This technical description is provided to describe the capability of General Electric's automated RPV inspection system (GERIS 2000)to meet the requirements of Regulatory Guide 1.150 paragraphs 7.b and 7.c and 10 CFR 50-55a(g).

Examination techniques described in this report are those used by General Electric when performing automatic ultrasonic inspections on ASME Code category B-D nozzle to vessel attachment welds.Scanning coverage documented in this report is for nozzle forging (flange type)to vessel seam welds.The ASME Boiler and Pressure Vessel Code referenced in this report is the 1980 Edition Winter 1981 Addenda.No automated inspection system in use today is capable of effectively examining 100%of the ASME Code examination volume defined in Section XI-IWB 2500-7(b).

This fact has been recognized in that the NRC Regulatory Guide 1.150 requires that volumes that are not examined be defined and documented in the examination report.II.ASME CODE AND REGULATORY GUIDE 1.150 REQUIREIVIENTS Section 50.55a,"Codes and Standards," of 10 CFR Part 50 requires that Class I components per American Society for Mechanical Engineers Boiler and Pressure Vessel Code (ASME BKPV Code)meet the requirements set forth in Section XI,"Rules for Inservice Inspection of Nuclear Power Plant Components," of the ASME Code.Section XI IWB-2500-1 requires that nozzle-to-vessel welds be examined by volumetric inspection techniques.

The area to be volumetrically examined for nozzle-to-vessel welds per.Figure IWB-2500-7(b) is defined as the weld metal plus adjacent base material regions as shown in Fig.1.C~CODE VGLUME Fig 1-Nozzle Weld Examination Volume godtechr1 The area to be examined for nozzle-inner radius and bore regions per Figure IWB-2500-7(b) is defined as the inner 1/2 inch of the inner radius and the nozzle bore through to the vessel wall thickness as shown in Fig 2.C~CODE VOLUME Fig 2-Nozzle Inner Radius and Bore Examination Volume Ultrasonic examinations are performed according to Article 4"Ultrasonic Examination When Dimensioning of Indications is Required" of Section V.Scanning is performed by angle beam and straight beam techniques per paragraphs T-441.5 through T-441.7 wherever such scanning is feasible.The United States Nuclear Regulatory Commission (NRCj has issued Regulatory Guide 1.150,"Ultrasonic Testing of Reactor Vessel Welds During Preservice and Inservice Examinations", to assure improved pressure vessel inspections.

The recommendations of this guide are supplemental to the requirements of Section XI.For volumes that are inaccessible to the transducer, or volumes shadowed by part geometry that have not been effectively examined, Regulatory Guide 1.150 paragraph 7.b requires that a.best estimate of the affected volume be reported along with the ultrasonic examination results.godtechr 1 III.AUTOMATED NOZZLE SCANNER Nozzle-to-Vessel Weld and Nozzle Inner Radius Scanner The nozzle device, mounted on a channel track clamped around the nozzle OD cylindrical surface, provides the means of performing a remote ultrasonic examination of the nozzle welds (Fig 3).The nozzle device includes the nozzle tractor, scanner arm and transducer package.Scanner Transducer Package Tractor Nozzle Weld Centerline Front View Track Side View Fig 3-Nozzle-to-Vessel Weld Scanner The nozzle tractor consists of a main body with two motor driven magnetic wheels and two hinged end sections, each with one motor driven magnetic wheel.assembly.A pendulum and resolver are mounted on the main body to give the angular position of the nozzle tractor.The reciprocating scanner arm is attached to the nozzle tractor and extends perpendicular to the nozzle track for scanning the nozzle to vessel welds and nozzle inner radius.The scanner arm consists of a frame, two tandem mounted stepping motors, a worm gear driven resolver, and a ball screw driven plate which holds the ultrasonic transducer package.The scanner arm is held to the vessel wall with two spring loaded guide rods on the inboard end and two magnetic wheels mounted at the outboard end of the scanner arm.godtechr 1 The transducer package consists of a combination of various transducer wedges ndividually mounted in a frame.The wedges produce beam angles as required by Section V.To improve coupling and efficiency, a specially designed transducer package assembly is utilized which allows independent transducer suspension and couplant delivery.Safe-End Mounted Scanner The safe-end mounted scanner (Fig 4I attaches to a channel track clamped around the nozzle safe-end, and provides the means of performing a remote ultrasonic examination of the nozzle inner bore surface.The safe-end mounted scanner is designed for scanning the nozzle bore inner surfaces.SCANNER AIL%VESSEL ooo 4 o 4 4 0 I'RACTOR NOZZLE o TRANSDUCER PACKAGE NOZZLE SAFE END TRACK FRONT SIDE Fig 4-Safe-End Mounted Scanner The safe-end mounted tractor consists of a main body with two motor-driven magnetic wheels and two hinged-end sections, each with motor-driven magnetic wheel assemblies.

A pendulum and resolver are mounted on the main body to give the angular position of the tractor.The reciprocating scanner arm is attached to the tractor and extends perpendicular to the safe-end track for scanning the nozzle-bore region.godtechr 1 IV.TECHNIQUES FOR NOZZLE-TO-VESSEL WELDS The accessible examination volume of nozzle-to-vessel welds is examined by using three types of scanning packages as described below.Transverse Scan for parallel oriented reflectors The T-scan (sound beam transverse to the weld axis)transducer package consists of 45 and 60 degree angle beam and a 0 degree straight beam transducer as shown in Fig 5.The 45 and 60 degree angle beam transducers are angulated to produce sound beams that are perpendicular to weld centerline at the vessel inner surface.Weld Centerl-nozzle Nozzle Bore Fig 5-T Scan Examination Package The scan coverages for the T-scan examinations are shown in Fig 6.The examination begins with the T-scan package adjacent the nozzle OD blend radius which is located at Pos 1, the package is scanned radially outward so that the sound beam will pass through-1/2 T (vessel wall thickness) of vessel base metal material (right dashed line).The radial distance needed for the 45 degree transducer is the distance between Pos 2 and Pos 3 for the 60 degree transducer.

One complete revolution of the nozzle scanner, with the T-scan package will scan the accessible examination volume for parallel oriented reflectors using 45 and 60 degree angle beams.godtechr 1 POS.l POS.E POS.3!Fig 6-T-scan Examination Coverage Parallel Scan for transverse oriented reflectors The P-scan (sound beam parallel to the weld axis)transducer packages (P1 and P2)consists of 45 and 60 degree angle beam transducers.

The transducers are angulated to produce sound beams that are tangent to the weld centerline at the vessel inner surface.The P1-scan consists of the 45 and 60 degree angle beam transducers pointed in.he counter-clockwise direction as shown in Fig 7.60 CClf lf ELD CENTERUNE NOZZLE BORE Fig 7-P1 Scan Examination Package For the P2 scan, the transducers are rotated to have the sound beams pointed in the clockwise direction as shown in.To compensate for the transducer offset distance from he center of the scanner axis, changes are made to the rotation angles.This compensation results in different rotation angle values for the clockwise and counter-clockwise directions.

godteChrl SO Cw WELO CENTERLINE

-NOZZLE BORE Fig 8-P2 Scan Examination Package Two complete revolutions of the nozzle scanner are made.One revolution with the P1 package and another revolution with the P2 package are performed to scan (from two directions) the accessible examination volume for transverse oriented reflectors.

The scari coverages for the P-scan examinations are shown in Fig 9.The examination begins for the P-scan (P1 and P2)package adjacent the nozzle OD blend radius located at Pos 1.The package is moved radially outward for a distance so the sound beams pass through 1/2 T of vessel base metal material (right dashed line).The radial distance for the 45 degree transducer is Pos 2, and Pos 3 for the 60 degree transducer.

POS.I POS.8 POS.3 Fig 9-P scan examination coverage godtOChr1 Weld and Base Metal Examinations The L-wave scan (0 degree longitudinal) examination is performed with one 0 degree longitudinal beam transducer located in the T-scan package.This single transducer performs dual functions.

The first function is the weld metal examination and the second is the base metal examination.

The scan coverages for the L-wave weld and base metal examinations are shown in Fig 10.The examination begins with the L-wave scan package adjacent the nozzle OD blend radius located at Pos 1.The package is moved radially outward so that the sound beam will pass through 1/2 T (vessel wall thickness) of vessel base metal material (right vertical dashed line).The radial distance needed for the 0 degree weld metal examination is Pos 2 and Pos.3 for the 0 degree base metal exam.The base metal scan examines the volume of base metal material for laminations that would interfere with the angle beam examinations.

POS.I POS.2 I I I POS.3 Fig 10-L-wave Weld and Base Metal Coverage One complete revolution of the nozzle scanner, with the T-scan package will scan the accessible examination volume for planar and laminar reflectors using a 0 degree straight beam.V.EXAMINATION TECHNIQUES FOR NOZZLE-INNER RADIUS AND BORE.The nozzle inner radius and bore are divided into five examination zones and are identified as Zones 1, 2A, 2B, 3, 4A, 4B and 5 as shows in Fig 11.Each zone is examined by a separate testing technique.

Each examination technique has its own unique transducer array.godtechr1 10

~ESSEL CLAD NOZZLE SAFE END l 4A~3-BB*~Fig 11-Nozzle Inner Radius and Bore Examination Zones To meet the ASME Section XI requirements, examinations are performed on Zones 1 and 2A.On Feedwater nozzles NUREG-0619 requires augmented examinations of Zones 1 through 5.Zone 1 Examination The nozzle inner radius (Zone 1)is normally examined from the vessel plate with a refracted shear wave that passes through the nozzle-to-vessel weld as shown in Fig 12.The Zone 1 scan consists of two transducers, one, directed in the clockwise direction and the other in the counter-clockwise.

This scan is performed with the nozzle scanner as shown previously in Fig 3.CCW WELD CENYERUNE-NOZZLE BORE Fig 12-Zone 1 Examination Package godtechf1 11 The sound beam is directed to intersect the inner-radius at a favorable angle (normal to an inner-radius flaw)for flaw detection.

Sound beam and rotation angles are dependent on the individual nozzle geometry.The scan coverage for the Zone 1 examination is shown in Fig 13.The examination begins with the Zone 1 package adjacent to the nozzle OD blend radius which is located at Pos 1;the package is scanned radially outward so that the sound beam will pass through inner-radius volume (right dashed line).The radial distance needed for the Zone 1 transducer is the distance Pos.1 and Pos 2.One complete revolution of the nozzle scanner, with the Zone 1 package will scan the accessible examination volume of the Zone 1 region for axially-oriented flaws.POS.I POS.2 Fig 13-Zone 1 Examination Coverage In addition, scanning the inner-radius from the nozzle OD blend radius may be preferred on certain nozzle configurations.

As is the case for the Zone 1 examination from the vessel plate, the sound beam and rotation angles are dependant on nozzle design.Zone 2A Examination The Zone 2A area of the nozzle bore is examined with shear waves from the surface where the nozzle OD blend radius merges with the cylindrical surface of the RPV as shown in Fig 14.This scan is performed with the nozzle scanner as previously shown in Fig 3.godtechr1 12 WELD CENYERUNE NOZZLE BORE Fig 14-Zone 2A Examination Package The sound beam is designed to intersect the nozzle bore at a favorable angle (normal to a nozzle-bore flaw)for flaw detection.

Sound beam and rotation angles are dependent on the individual nozzle geometry.The scan coverage for the Zone 2A examination is shown in Fig 15.The examination begins with the Zone 2 transducer adjacent the nozzle OD blend radius located at Pos 1.The package is moved radially inward so that the sound beam will pass into the nozzle bore equivalent to a distance of vessel wall thickness (upper horizontally dashed line).The radial distance needed for the Zone 2 examination is the distance between Pos 1 and Pos 2.POS.2 POS.1 Fig 15-Zone 2A Examination Coverage godtechr1 13 One complete revolution of the nozzle scanner, with the Zone 2A package will scan the accessible examination volume of the Zone 2A region for axially-oriented flaws.Coverage typically includes parts of the Zone 1 and 2B regions.Zone 2S Examination The Zone 2B area of the nozzle bore is examined with shear waves from the nozzle OD cylinderical surface as shown in Fig 16.The Zone 2B scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise.

This scan is performed with the safe end scanner as shown previously in Fig 4.CCW CW NOZZLE OD-NOZZLE BORE-SAFE END OD Fig 16-Zone 2B Examination Package The sound beam is designed to intersect the nozzle bore in the Zone 2B region of the nozzle bore.Sound beam and rotation angles are dependent on the individual nozzle geometry.The scan coverage of the Zone 2B examination is shown in Fig 17..The examination begins with the Zone 2B package adjacent to the nozzle OD blend radius which is located at Pos.1.The package is scanned axially toward the end of the nozzle OD cylinderical surface which is located at Pos.2.godtechr1 14 POS.2 pos.Fig 17-Zone 2B Examination Coverage One complete revolution of the safe-end scanner, with the Zone 2B package will scan the accessible examination volume of the Zone 2B region (area not examined with the Zone 2A examination) for axially-oriented flaws.Zone 3 Examination The Zone 3 area of the nozzle bore is examined with shear waves from the nozzle OD cylinderical surface as shown in Fig 1.8.The Zone 3 scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise.

This scan is performed with the safe end scanner as shown previously in Fig 4.-NOZZLE OD-NOZZLE BORE-SAFE EiVD OD Fig 18-Zone 3 Examination Package godtechr1 IS The sound beam is designed to intersect the nozzle bore in the Zone 3 region of the nozzle bore.Sound beam and rotation angles are dependent on the individual nozzle geometry.The scan coverage of the Zone 3 examination is shown in Fig 19.The examination begins with the Zone 3 package adjacent to the nozzle OD blend radius which is located at Pos.1.The package is scanned axially toward the end of the nozzle OD cylinderical surface which is located at Pos.2.POS.2 POS.Fig 19-Zone 3 Examination Coverage One complete revolution of the safe-end scanner, with the Zone 3 package will scan the the Zone 3 region for axially-oriented flaws.Zone 4A Examination The Zone 4A area of the nozzle bore is, examined with shear waves from the nozzle OD cylinderical surface as shown in Fig 20.The Zone 4A scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise.

This scan is performed with the safe end scanner as shown previously in Fig 4.godtechr1 16 CciY C3V YiOZZLE OD iilOZZLE BORE SAFE Ei~D OD Fig 20-Zones 4A and 4B Examination Package The sound beam is designed to intersect the nozzle bore in the Zone 4A region of the nozzle bore.Sound beam and rotation angles are dependent on the individual nozzle geometry.The scan coverage of the Zone 4A examination is shown in Fig 21.The examination begins with the Zone 4A package adjacent to the nozzle OD cylinderical which is located at Pos.1.The package is scanned axially to the nozzle-to-safe end blend radius surface which is located at Pos.2.POS.2 POS.i Fig 21-Zone 4A Examination Coverage One complete revolution of the safe-end scanner, with the Zone 4A package will scan the the Zone 4A region for axially-oriented flaws.godtechr1 17 Zone 4B Examination The Zone 4B area of the nozzle bore is examined with shear waves from the nozzle-to-safe-end blend radius surface with the transducer similar to that as shown in.The Zone 4B scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise.

When geometry permits (large blend radius), this scan is performed with the safe end scanner as shown previously in Fig 4, else it is performed manually.The scan coverage'of the Zone 4B examination is shown in Fig 23.The examination begins with the Zone 4B package adjacent to the nozzle taper which is located at Pos.1.The package is scanned axially to the nozzle-to-safe end OD surface which is located at Pos.2.POS.2 POS.Fig 23-Zone 4B Examination Coverage One complete revolution of the safe-end scanner, with the Zone 4B package will scan the the Zone 4B region for axially-oriented flaws.Zone 5 Examination The Zone 5 area of the nozzle bore is examined with shear waves or RL (depending on safe end material)from the nozzle-to-safe end OD surfaces as shown in Fig 24.The Zone 5 scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise.

This scan is performed with the safe end scanner as shown previously in Fig 4.An alternate method is to perform this scan with the SMART 2000 Ultrasonic system.godtechr 1 18 CC~V ClY-NOZZLE OD-NOZZLE BORE-SAFE END OD Fig 24-Zone 5 Examination Package The scan coverage of the Zone 5 examination is shown in Fig 25.The examination begins with the Zone 5 package adjacent to the nozzle-to-safe end blend radius which is located at Pos.1.The package is scanned axially to the position on nozzle-to-safe end OD surface which is directly above the point on the thermal sleeve where leakage could occur and is located at Pos.2.POS.2 POS.i Fig 25-Zone 5 Examination Covexage One complete revolution of the safe-end scanner, with the Zone 5 package will scan the the Zone 5 region for axially-oriented flaws.godteclv1 19 IV.SCANNING COVERAGE The flanged nozzle design when examined from the outside vessel surface does not allow a full volummetric inspection of the volume specified in figure IWB-2500-7(b).

The primary limitation is due to the fact that the volume can only be examined from one side and in one direction and is recognized by the ASME Code.Another limitation in scanning the N2H and N2J Recirculation Inlet nozzles was an adjacent N9 Jet Pump Instrument nozzle.The use of a shorter scanning arm was needed to scan this area.The automated transducer (60'scan)could not scan back enough to cover the entire 1/2 T of vessel base material.With this limitation, 87%of the nozzle was scanned with 100%of accessible coverage, while the remaining 13%of the nozzle was scanned with 98%of accessible coverage obtained.Scan Limitations and Volume of Coverage.Table 1 summarizes the examined volume from the coverage plots contained in the examination data packages.Areas not examined due to near field effects reflected in the following table (this area has been determined to be the outer 0.5" of examination volume).SCAN TYPE CODE VOLUME (SQ.IN)VOLUME EXAMINED{SQ.IN)OF TOTAL CODE VOLUME EXAMINED%OF ACCESSIBLE VOLUME EXAMINED 0 WM 65.2 26.4 40 100 45o T 65.2 44.5 68 100 6Q T 60o T 65.2 65.2 48.4 47.2 74 72 100 98 45 P 6Q P INNER RADIUS 65.2 65.2 4.0 33.9 41.8 4.0 52 64 100 100 100 100+-SCANNING VOLUME RESTRICTED BY N9 Table 1-Cross-sectional examination volume.Supplemental manual examinations (nozzles)S upplemental manual examinations to cover the area missed by the automated scanner (60 T scan)between the N2 and N9 nozzles would increase the cross-sectional coverage by 1.2 sq.in.Due to the minimal amount of Code Volume not covered with the 60'scan (2%of accessible), and the fact that 45 T, 45 P and 60 P scans were performed in this estricted region, no supplemental examination was performed.

godtochr1 20 RF&IO 8 Coverage Report APPE IX A Code Examination Coverage Summary Summary Component Exam Coverage RF&IO 8 Coverage Repog Composite Code Coverage and Restrictions 625019 AA BEEAD-SC1 O'M 45 T-scan 60'T-scan 45'P-scan 60'P-scan 100 99.3 96.25 100 100 99%GERIS 2000 Exam restricted at N1A, B and N8A, B.iManual Exam unrestricted.

Supplemental Manual exams performed at N1A, B and NSA, B.625023 AF 0'120M 45'T-scan 60'T-scan 45'P-scan 71 95.4 97.2 71 100%Manual examination coverage of bottom side limited due to flange configuration.

Credit taken for ligament exam brings total credit to100%.(Scheduled Examination from 0'o 120')625020 625021 BA SC1 LONG BB SC1 LONG O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 100 82.5 82.5 82.5 82.5 100 100 100 100 100 86%GEMS 2000 Exam restricted at N2K.No Supplemental manual exams performed this outage.Vpon corn-pletion of supplemental exams during RF 2 IO 9 100%coverage will be achieved.100%GEMS 2000 Exam restricted a N2C.Supplemental Manual exams were performed in this area.625022 BC SC1 LONG O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 100 100 100 100 100 100%GERIS 2000 Exam restricted a nozzles N1B and N2F.Supplemental Manual exams performed in these areas.625027 N1A NOZ-SC1 O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 48.2 80 87 52 41.2 61.7%GEMS 2000 scanning unrestricted.

Summary Component Coverage RF&IO 8 Covenge ReIN~Composite Code Coverage and Restrictions 625024 625028 N1A I.R.NOZ-IR N2A NOZ-SC1 Zone 1 Zone 2a O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 100 100 48.6 79.3 86.2 53.3 60.6 100%GERIS 2000 scanning unrestricted.

65.6%GERIS 2000 scanning unrestricted.

625025 625029 N2A IR NOZ-IR N2F NOZ-SC1 Zone 1 Zone 2a O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 100 100 47.6 79.3 86.2 53.3 60.6 100%GERIS 2000 Exam unrestricted.

65.4%GERIS 2000 Scanning unrestricted.

625026 N2F IR NOZ-IR Zone 1 Zone 2a 100 100 100%GERIS 2000 Exam unrestricted.

625030 N4A NOZ-SC3 O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 48.6 73.8 77 52.6 58.7 62%GERIS 2000 Exam restricted at N11A.Supplemental Manual exams performed in this area, with a L=O to L=+4.5 625001 N4A IR NOZ-SC3 Zone 1 Zone 2a 92.3 100 96.2%GERIS 2000 Exam restricted at N11A.Supplemental Manual exams performed in the areas with a D=O to D=+4.5.625003 N4A-BORE FW NOZZLE BORE Zone 2b Zone 3 Zone 4a Zone 4b 100 100 100 100 100%GERIS 2000 Exam unrestricted.

23 Summary Component Exam Coverage RF&, IO 8 Coveni,e Report Composite Code Coverage and Restrictions 625031 N4B NOZ-SC3 O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 48.4 79.3 86.2 53.3 60.6 65.6%GERIS 2000 Scanning unrestricted.

625004 625006 N4B IR NOZ-IR N4B-BORE FW NOZZLE BORE Zone 1 Zone 2a Zone 2b Zone 3 Zone 4a Zone 4b 100 100 100 1'00 100 100 100%GERIS 2000 Exam unrestricted.

100%GERIS 2000 Exam unrestricted.

625032 N4C NOZ-SC3 O'M 4S'T-scan 60'T-scan 45'P-scan 60'P-scan 48.6 79.3 80 53.2 60.6 64.3%GERIS 2000 T-scan exam at N9A (Azimuth 65'o 95')limited to a radial distance of 12 inches.625007 N4C I.R.NOZ-IR Zone 1 Zone 2a 100 100 100%GERIS 2000 Exam unrestricted.

625009 N4C-BORE FW NOZZLE BORE Zone 2b Zone 3 Zone 4a Zone 4b 100 100 100 100.100%GERIS 2000 Exam unrestricted.

625033 N4D NOZ-SC3 O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 52.6 74 76.8 52.6 58.7 63%GERIS 2000 Exam restricted at N11B.Supplemental Manual exams performed.

in this area, with a L=O to L=+4.5 625010 N4D IR NOZ-IR Zone 1 Zone 2a 92.3 100 96.2%GERIS 2000 Exam restricted at N11B.Supplemental Manual exams performed in this area with a D=O to D=+4.5.

Summary Component ExaIII Coverage RF 4 10 8 Coverage Repog Composite Code Coverage and Restrlctlons 625012 N4D-BORE FW NOZZLE BORE Zone 2b Zone 3 Zone 4a Zone 4b 100 96 90.8 100 96.7%GERIS 2000 Scanning unrestricted.

625034 N4E NOZ-SC3 O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 48.4 79.3 86.2 53.3 60.6 GERIS 2000 Scanning unrestricted 625013 625015 625035 N4E IR NOZ-IR N4E-BORE N4F NOZ-SC3 Zone 1 Zone 2a Zone 2b Zone 3 Zone 4a Zone 4b O'M 45'T-scan 60'T-scan 45'P-scan 60'P-scan 100 100 100 100 100 100 48.4 79.3 86.2 53.3 60.6 100%GERIS 2000 Exam unrestricted 100%GERIS 2000 Exam unrestricted 65.6%GERIS 2000 Scanning unrestricted.

625016 625018 N4F IR NOZ-IR N4F-BORE Zone 1 Zone 2a Zone 2b Zone 3 Zone 4a Zone 4b 100 100 100 100 100 100 100%GERIS 2000 Exam unrestricted.

100%GERIS 2000 Exam unrestricted.

I 25 SUSQUEHAi PilA STEAiVl ELECTRIC STATION UMT I RPV INSERVICE E~VQNATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EKVVIINATION RESULTS

SUMMARY

REPORT"~

Summary Report COMPARISON OF EXAMINATION RESULTS Number 3: The data gathered during the Susquehanna Unit 1 Eighth Refueling and Inspection Outage provides an assessment of RPV integrity.

This is a requirement of both ASME Section XI and USNRC Regulatory Guide 1.150.The overall results regarding coverage and detected indications were compared to those from the previous examinations.

There were minor differences in coverage for these welds.This is attributable to equipment modifications during the elapsed time period between the examinations.

The differences are not considered to be significant.

There were significant differences in the number of indications detected and in the amplitudes of the detected indications.

These were attributable to differences in transducers, exam techniques, and an acoustic difference between Calibration Blocks 1 and 5.Appendix 1 of this report details the actions taken to determine the origin of the differences.

Each recordable indication was analyzed, along with any differences in examination coverage, etc., by a certified Level III individual.

These analyses are a part of the data package generated for every item examined.The examination data and required analyses are on file at the site.Based on the results of these examinations, there is no sign of"Abnormal De~dation" of the Reactor Pressure Vessel.There were no indications that required reporting to the USNRC per Reg.Guide 1.150.

Summary Report APPENDIX 1 Number 3 During the 1989 Inservice Examination of Weld BA, numerous indications were detected by the 0'eld metal scan.The analysis of these indications showed them to be caused by plate se~~gates.

PP&L had the EPRI NDE Center confirm the analysis by Ultrasonic and Destructive Testing.fl Since there was a,commitment to re-inspect Weld BA periodically to confirm that these indications are not growing, Weld BA was inspected during R&IO 8.The previously recorded segregates were not present at the ASiVEE Code sensitivity used to process data.This was a significant difference that was analyzed as follows: The systems used for these examinations were different.

The 1989 examination was performed with a GERIS system.The 1995 examination utilized a GERIS 2000 system.There are operational dift'erences between these systems.The major difference is that the GERIS is an amplitude based system while the GERIS 2000 records all data down to the material noise level.GERIS data was analyzed based on the sensitivity obtained 6'om the calibration standard.GERIS 2000 data was analyzed by processing with the DAC obtained during calibration being applied to all data.This is a significant difference that should have resulted in the recording of more small laminar indications, rather than less.Because the opposite happened, further analysis was performed.

Since the GERIS 2000 records all data, it was possible to search for the indications by reprocessing the data to extract and display lower amplitude peaks.It was determined that the indications were indeed present in the data, but at amplitudes averaging-16dB (>5X)below the 1989 levels.The GERIS 2000 system was checked and found to be operating properly.It was determined that the cause was not"System Related" so other factors were analyzed.A data review showed that Calibration Block 1 was used for the PSI and the 1995 exams, while Calibration Block 5 was used in 1989.A comparison of acoustic properties between blocks 1 and 5 was performed.

It was determined that the responses I'rom all holes in Block 5 averaged-14dB less than Block 1.When the 1995 data is reprocessed utilizing a reconstructed DAC with values similar to those obtained on Block 5, it compares well with the 1989 results.The data differences were attributable to a difference between calibration blocks.There does not appear to be a ready explanation for the difference.

Both of these blocks were fabricated Rom the same vessel knock-out eliminating the possibility of chemistry differences.

SUSQUEHANNA STEAlM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVIINATION EIGHTH REFUELING AiG)INSPECTION OUTAGE REPORT OF EXAMINATION RESULTS

SUMMARY

REPORT P4 Summary Report EQUIPMEVT VARIABLES THAT COULD AFFECT DIRECT COMPARISON OF RESULTS Number 4 FROM PREVIOUS OR FUTURE EXAMINATIONS The results of Nondestructive Examinations (NDE)are affected by variations in equipment operating characteristics.

These can also affect comparisons of results between a series of examinations.

Since there is little published data concerning these variables, GE performed an in house study to quantify them for the GERIS 2000 and Manual examination systems used on GE Contract work.This data forms the basis that enables performance of a comparison of results between examinations performed over a period of time;regardless of equipment type.There are several broad categories of equipment perfonnance parameters that affect direct comparison of different data sets.The effects of these factors has been estimated by GE, based on both laboratory work and field experience.

The factors are: 1.System operational characteristics and the operational differences between equipment types.2.The tolerances in equipment operational characteristics applied by equipment manufacturers.

3.Differences in transducer characteristics.

The following paragraphs contain a discussion of each item, a comparison of each item as it affects each system, and the effect of each on data correlation.

SI STEM OPE2biTIOPAL CSEriRACTERISTICS The major difference in operational factors for the GERIS 2000 and Manual examination systems used at Susquehanna are due to system design.There are major differences between the data acquisition methods used in Manual systems and those employed by the GERIS 2000 system.These are discussed below: GENS 2000 Characteristics The Dynamic Range of the system is 85 dB as a minimum.System bandwidth is considered to be narrow.The system uses tuned Pulsers and Receivers that operate at optimum effeciency in the range of 1.0 liz through 5.0 Mhz.Search units are selected to provide optimum performance with the system.Manual System Characteristics This RF/Video circuitry is meant to provide good performance over a broad range of search units.The bandwidth is considered to be broad.It is meant to operate over a range 6om 1.0 Mhz-10.0 iVZz with adequate performance.

Search units are selected based on adequate performance with the instrument being used.This performance may or may not be optimum.As shown above these systems are designed to operate differently.

Presently neither the ASME or the USNRC consider these differences when addressing data comparisons.

With implementation of Appendix VIII of Section XI, it appears that more data about the effects of these items will become available.

Presently, there is a lack of research data to quantify the effect of these parameters.

Research performed at Pacific Northwest Laboratory (NUREG/CR2264) indicates that tuned instruments offer more consistent results than broader band instruments.

DMVUFACTURER'S TOI ERASES FOR 11VSTRViME)VTS The ultrasonic test instruments used in examination systems, are designed and built to operate within a finite set of tolerances specified by the individual manufacturer.

These parameters and tolerances differ between manufacturers but are consistently applied to given models e.g.all Krautkramer USL<8's use the same tolerances but they may or may not apply to USK-7's.Each instrument manufacturer determines what constitutes acceptable performance tolerances for their products, based on the end use(s)they intend for them.It would be unreasonable to expect an instrument that has to provide acceptable performance over a wide range of uses to work as well on a specific use, as one designed for that specific use.The GERIS 2000 used at Susquehanna, contains a single multiplexed UT system.The effect of manufacturing toletances on examination data is, therefore, minimal.The UT data is produced using pulsers, receivers, logarithmic amplifier, and filtering specifically designed to provide optimum performance as a complete system.Components and parts are replaced with only those having the same characteristics.

Each sub-system affects all data equally.Incipient failures are readily detectable and components are replaced before any effect on data can occur.The manual systems used at Susquehanna contain instruments from several manufacturers.

The effect of tolerances is present in the data and should be accounted for in data comparisons.

Experience has shown that different instruments, each operating within the tolerances specified by the manufacturer, can produce widely varying responses from the same reflector.

At one operating plant, an indication that was present one year disappeared then reappeared during two subsequent examinations.

The cause was found to be the instruments used, even though each was operating as designed by the manufacturer.

Testing performed by GE shows a spread of+5.5dB between instruments produced by a single manufacturer.

The test data was generated using the same cable, transducer, wedges, and reflector.

The instruments were the only variable.While a single manufacturer's instruments were used in this test, it is reasonable to assume that data gathered using several manufacturer's instruments could show a wider spread.An 11.5 dB spread adds to the difficulty of directly comparing data from a series of examinations on the same component.

Instrument differences must be accounted for during any comparison.

TRrilYSDUCER CHrQACTERISTICS Transducers are the most variable component in an examination system.A single transducer can vary over a period of time due to aging, mechanical damage, and wear.Variations between transducers, especially lrom different manufacturers, are due to differences in design, materials, assembly techniques, damping and the active element shape.These cause wide variations in electromechanical efficiency between transducers, leading to differing examination results.These items, alone or in combination, can cause differences in results on the same reflector during successive examinations.

They are also responsible for many differences in data when an indication detected with an automated system is verified using a manual system.Of the items above, the ones best understood and documented are transducer shape and electromechanical efficiency.

The GERIS 2000 uses transducers that are eliptical (22 x 32 mm and 18 x 32 mm angle beam)or round (25 mm straight beam).These shapes have a fairly uniform sound field.

More of the useful portion of the beam (-ldB to-6dB)is concentrated near the center.This means that small flaws are likely to be interrogated by the strongest portion of the beam.This increases the likelyhood that small flaws will be recorded during an automated examination.

The manual examination systems use rectangular, I/2" x 1", and round 1" diameter transducers.

The sound field with a rectangular transducer is not as uniform as with a round element.The useful portion of the beam is not as concentrated.

Small flaws are not as likely to be interrogated with the strongest portion of the beam.Manual exams traditionally record fewer low amplitude flaws than automated exams;for this reason.The GERIS 2000 uses transducers selected to match system operating characteristics.

The electromechanical effiency of these transducers is closely matched.The manufacturer's certification allows selection of search units with similar efficiency.

The transducers used in manual examination systems are catalogue items.The electromechanical effiency of these transducers is not closely matched.A measurement, called Relative Sensitivity (RS), is used to measure efficiency.

Relative sensitivity is calculated by measuring the attenuation required to reduce the amplitude of a return signal to a predetermined value;usually 300 millivolts.

The higher the required attenuation the greater the efficiency.

The RS provides a way to select transducers of similar efficiency, by selecting those within a discreet range of RS attenuation measurements.

The RS range for the transducers used with manual systems is based on the search units available.

'Selection of search units for successive examinations of the same indication should account for the possible differences in efficiency.

DISCUSSION The equipment used during an examination can affect the recording of indications during an examination.

The effect of the various components, for the systems used at Susquehanna, are estimated below.These effects have been observed over a number of examinations and the results of these have been used to refine the theoretical data.While these effects exist, they have not been as large as expected based on theoretical estimates.

System characteristics Instrument tolerances Transducer efficiency Theoretical effect+3dB Theoretical effect unknown Theoretical effect+6dB Transducer shape (small flaws)Theoretical effect+6dB Observed effect negligible.

Observed effect+5.5dB.Observed effect+3dB Observed effect+3dB The data shown above shows a maximum expected difference in performance between systems of 23dB.This compares well with the observed differences between these systems.At other Plants, the differences have ranged Rom 4dB through 14.5 dB.This yields an average difference of 9.25 dB.These differences are monitored during each examination.

This estimate will be updated during the next use of the GERIS 2000 at Susquehanna, if required.Direct comparisons of indications, between automated and manual examination data, is difficult for the reasons presented above.If such comparisons become necessary, care should be exercised.

Equipment should be selected based on operational characteristics that closely match what was used to detect the flaw originally.

Even so, there could be an 11.5 dB difference in results.As long as these differences are considered, such comparisons can be made.

EROSION/CORROSION SCOPE OF ZX~MIN~nOXS E NUMBER UNIT 1-BRIO--EROSION/CORROSIOrc EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCO ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP HO.WA NO DETAIL PLAN ACC 2 LINE COMMENTS CROSSAROUND-E6 CROSSAROUND VT I-EXAM ELBOW X-17 SIZE 42 ELEV GRID MSEPD 6 TB 10 708 T-21 1 0.00 8 5N I 7-10EHB EWRHUM EXM SCH.625.417 X-RIOB ROOM ERATE INSUL MIH WALL ISI ISO MEAS MIN OUT DTE CROSSAROUND D.B RESP95 ACTIVITY NO K-594 P43760 K0594-01 DBD101 1-E3 RFP FE-1H001A INLET Zl TEMP ELBOW X-50 18 FW 10 TB 9 740 T-422 0.00 8 7'519-6'WN 1.375 I.049 X-RIOB DBD-101-1 0.29 RESP95 K-563 P43674 K0563-01 DBD1013-E2 RFP 8 EXIT ELBOW X-58 18 FW 10 TB 0 678 T-122 17 79 8 8'520-4'WL 1.375 DBD-10 1-3 K-564 P43675 1.049 D.38 K0564-0 I X-RIOB RESP95 DBD1015-E 1 90 ELBOW RFP FE-1HOO IB INLET Z 1-TEMP X-61 18 FW 10 TB 9 740 T-422 26.68 8 8'N20-2'WN 1.375 1.049 X-RIOB DBD-101-5 D.38-RESP95 K92 K0092-01 P43649 DBD1015-E2 90 ELBOW RFP FE-IN001C INLET Z 1-TEMP X"65 18 FW 10 TB 9 740 T-422 31.59 8 5'N20-2'WN 1.375 080-101-5 K93 P43650'1.049 D.39 K0093-01 X-RIOB RESP95 DBD1041-E 1 RFP A MIH FLOW TEE 8 X-53 10 FW 6 670 T-36 5'N20-7'WJC TB 11 12.84 8.844 DBD-104-1 K-565 P43676.626 D.34 K0565-O'I X-RIOB RESP95 DBD1042-E 1 RFP 8 MIN FLOW TEE 8 X-152 10 FW 7 670 T-31 6'N22-7'WJC TB 12.844 DBD-104-2 K-566 P43677 25.23 8.626 0.72 K0566-01 X-RIOB.RESP95

NUMBER 2 UNIT'I-BRIO--EROSION/CORROSION EXAMS-REPORT 2 (SORTEO BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE COMMENTS DBD1043-El RFP C MIN FLOW TEE 8 X-153 10 GRID FW 7 TB 12 670 T-31 15.87 8 3'S21-10'EHE EWRNUM EXM SCH.844.626 X-RIOB MEAS MIN OUT OTE DBD-104-3 D.73 RESP95 ACTIVITY NO K-567 P43678 K0567-01 OBD1051-E2 ELBOW RFP A LOW LOAD BYPASS X-55 14 FW 11 TB 732 T-422 0.00 8'521-4'WN 0 1.094 DBD-105-1 K-568 P43679 8.816 D.35 K0568-01 X-R IOB RESP95 DLA1021-E3A

'A'FW TO RPV (MAIN)Zl,Z2 TEMP TEE 0 X-175A 20 FW 26 RB 0 1.031 DLA-'102-1 K95 P43651 754 R-516 0.00 M.687 D.82 270DEG AZ 8 22RCL K0095-01 X-RIOB RESP95 DLA 1021-E38 TEE D'A'W TO RPV (BRANCH)Zl, Z2 TEMP X-1758 12 FW 26 RB 0 754 R-516 26.2 M 270DEG AZ 8 22RCL.688 DLA-102-1 K95 P43651.459 D.82 K0095-01 X-RI 08 RESP95 DLA102'I-ES

'A'W TO RPV HAND GRID 90 ELBOW X-177 12 FW 26 RB 0.688 OLA-102-1 K96 P43652 754 R-516 41.92 M.459 D.82 210DEG AZ 8 22RCL K0096-01 X-RIOB RESP95 DLA1041-E3A RPV INLET 8 Zl-TEMP TEE 0 X-140A 20 FW 26 RB 0 1.031 DLA-104-1 K99 P43653 752 R-516 00.00 M.687 D.67 90AZ-22RCL K0099-01 X-RIOB RESP95 OLA 104 1-E38 RPV INLET 8 Z2-TEMP TEE D X-1408 12 FW 26 RB 0 752 R-516 26.2 M 90AZ-22RCL

..688.459 X-RIOB DLA-104-1 RESP95 K99 K0099-01 P43653 P>GE NUMBER 3 UHIT I-BRIO-EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DETAIL PLAN ACC 2 LINE COMMEHTS OLA I 04'I-E4A RPV INLET B HAND GRID DESCRIPTION REDUCER REPLCD ID X-141A SIZE 20 ELEV GRID ROOM ERATE IHSUL FW 26=754 R-516 90AZ-22RCL RB 0 33.72 M SYSTEM AREA BUILD SCAFF NOM WALL MIN WAI.L EWRNUM EXM SCII 1.031.687 X-R I 08 LINE ISI ISO MAP NO.WA NO OUT DTE OLA-104-1 D.67 RESP95 K100 K0100-01 P43654 MEAS MIN-ACTIVITY NO DLA I 041-E48 RPV INLET 8 HAND GRID REDUCER X-14 IB 12 FW 26 RB 0.688 754 R-516 29.69 M.459 90AZ-22RCL X-RIOB DLA-104-1 D.67 RESP95 K 100 K0100-01 P43654 DLA1041-ES RPV IHLET 8 Z I-TEMP 90 ELBOW X-142 12 FW 26 RB 0 754 R-516 38.43 M ISODEG AZ-23'RCL.688.459 DLA-104-1 D.67 K156 K0156 01 P43659 X-RIOB RESP9S GAD 1011-El TEE 8 MSEP DRAIN TO 4A Z I-TEMP X-I2 10 MSEPD 9 TB 707 T-215 88.82 14'N16-5'EL 5.500 GAD-101-1 8.330 D.3 M59 198 X-RIOB RESP95 K39 K0039-01 P43631 GAD1011-E2 VALVE A MSEP DRAIN TO FWH 4A EXISTING GRID X-167 MSEPD 9 707 T-215 4'SI5-8'EL TB 5 13.82 B.280.186 X-RIOB GAD-IO I-I 0.3 RESP95 K40 K0040-01 P43632 GAD1012-E I TEE 8 SIS: X-12, X-249 Z I-TEMP X-248'IO MSEPO 10 TB 6.500 708 T-214 34.11 8.330 14'H'19-5'EL X-RI 08 GAD-101-2 D.3 RESP95 K41 K 004'I-0 I P43633 GAD 1013" E I TEE 8 SIS: X-I2, X-248 ZI-TEMP, Z2-TEMP X-249 10 MSEPD 11 TB 6.500 GAO-101-3 K42 707 T-212 30.58 8.330 D.3 14'N24-5'EL K0042-01 X-RIOB RESP95 P43634 GE NUMBER 4 UNIT 1-BRIO--EROSION/CORROSION EXAMS-REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT ID DETAIL PLAH ACC 2 LINE COMMENTS GAO I 013-E2 VALVE A MSEP DRAIN TO FWH 4C REPLCD ID X-169 SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO GRID MSEPD ll 707 T-212 14'N24-3'EL TB 5 34.04 8 EWRNUM EXM SCH.280.186 MEAS MIN OUT DTE GAD-101-3 0.3 SYSTEM AREA BUILD SCAFF HOM WALL LINE MAP NO.WA NO ACTIVITY NO K-43 P43635 K0043-01 X-RIOB RESP95 GBD1021-E 1 EXTRACTIOH SA DRAIN 90 ELBOW X-192 EXTST 6 TB 0 701 T-211 24.05 8 1'S19-10'WK

.237.158 X-R I 08 GBD-102-1 0.75 RESP95 K-569 P43680 K0569-01 GBD1021-E2 EXTRACTION 5A DRAIN Zl-TEMP 90 ELBOW X-155 EXTST 5 TB 5.23?GBD-102-1 K45 P43636 708 T-211 72.15 8.158 0.75 6515-4WK M59201 K0045-OI X-RIOB RESP95 GBD1022-El EXTRACTION 58 DRAIN Zl TEMP 90 ELBOW X-191 EXTST 7 TB 0 701 T-211 56.96 8 O'N2)-6'EHE

.237 680-102-2 K49 P43640.158 D.74 M59200 K0049-01 X-RIOB RESP95 GBD1022-E2 90 ELBOW EXTRACTION 58 DRH Zl TEMP X-154 EXTST 6 TB 6 708 T-211 77.21 8 12N19-4WK.237.158 M59203 X-RIOB GBD-102-2 D.74 RESP95 K46 K0046-01 P43 637 GBD1023-E 1 ELBOW EXTRACTION JF5 C DRAINS X-126 EXTST 7 TB 0 701 T-211 26.58 8 1N23-1'EHE

.237 GBD-102-3 K-47 F43638.'158 D.1 I K0047-Ol X-RIOB RESP95 G801023"E2 EXTR 5C DRAIN (20C)Zi-TEMP 90 ELBOW X-25 EXTST 7 TB 5.237 GBD-102-3 K48 707 T-211 40.51 8.158 0.11 1'N23-4WK K0048-01 X-RIOB RESP95 P43639 E NUMBER 5 UNIT 1-BRIO-EROSION/CORROSIUn EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS GBD1031-E1A REDUCER SIS: GBD1032-E2A, GBD'1033-E1A Zl-TEMP REPLCD ID X-791 SIZE ELEV GRID ROOM ERATE INSUL FWHD 6 701 T-211)2'519-0'8JA TB 4.25 0 8 MIN WALL EWRNUM EXM SCH.322.215 ISI ISO MEAS MIN OUT DTE GBD103-1 GBD103-I SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO ACTIVITY NO K207 P43618 K0207-OI X-RIOB RESP95 GBD1031-E18 REDUCER SIS: GBD1032-E18, G801033-E18 Z 1-TEMP X-791 FWHD 6 TB 0 701 T-211 0.00 8 12'519-0'8JA

.280.187 X-RIOB GBD103-1 GBD'103-1 RESP95 K207 P43618 K0207-01 GBDI032-E1A REDUCER SIS: G801031-E1A, GBD1033-E'IA Z 1-TEMP X-793 FWHD 7 TB 0.322 701 T-2'll 17.02 8.215 12'2 1-1'J M59 199 X-RIOB GBD103-2 GBD103-2 RESP95 K206 K0208-01 F436 19 GBD 1032-E I 8 REDUCER SIS: GBD 103'I-E18, GBD1033-E18 Z'I-TEMP X-793 FWHD 7 TB 0.280 701 T 211 61.68 8.187 12'S21-1'EJ M59 199 X-RIOB GBD1032-2 GBD103-2 RESP95 K206-P43619 K0208-01 GBD1042-E 1 FWH 58 VENT ELBOW X-158 FW 10 TB 707 T-214 3.0 4'S19-16'WM 5.300 GBD-104-2 K-570 P4368 1 8.200 D.17 K0570-01 X-RIOB RESP95 GBD 1074-E I DEMIN 8 INLET ELBOW X-156 16 CDEM 10 TB 15 692 T-123 20.54 8 5'SI8-4'WN

.656.437 X-RIOB GBD-107-4 D.37 RESP95 K-57 I P43662 K057 I-O I GBD1074-E2 DEMIN.A INLET ELBOW X-57 16 CDEM 10 TB 15 692 T-124 31.05 8 4'S17-4'WN

.656.437 X-RIOB GBD-107-4 D.37 RESP95 K-572 P43683 K0572-01 GE NUMBER 7 UNIT 1-BRIO--EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT IO DETAIL PLAN ACC 2 LINE COMMENTS GBD1153-E 1 ELBOW FW S-U AFTER FO-10659C REPLCD ID X-36 SIZE ELEV GRID ROOM ERATE INSUL MIN WALL I SI ISO EWRNUM MEAS MIN FW 3 666 T-40 4'N21-10'EG TB 0.00 io 8 EXM SCH.280.187 OUT DTE GBD-115-3 D.22 SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO ACTIVITY NO K-578 P43687 K0578-01 X-RI 08 RESP95 GBD1153-E2 ORIFICE F.W.C START-UP FO-10659C X-47 FW 3 665 T-40 4'S20-10'EG TB 10 0.00 8.280 GBD-115-3 K-579 P43688.187 D.22 K0579-OI X-RIOB RESP95 GBDI182-El F.W.428 TO 38 Zl-HAND GRID 90 ELBOW X-150 20 FW 3 TB 8 712 T-2'I 1 57.19 8 6'N21-19'EG

.812.541 M59204 X-RI 08 GBD-118-2 0.70 RESP95 K63 K0063-01 P43645 GBD I 211-E2 RFP C INLET ELBOW X-63 20 FW 11 TB 8 686 T-128 11.43 8 1'23-13'WM.812.541 X-RIOB GBD"'I 21-1 0.30 RESP95 K"580 P43689 K0580-OI GBD1212-E 1 RFP A INLET ELB 8 RED X-45 20 FW 10 TB 10 686 T-128 36.53 8 I'19-5'L.812.541 X"RIOB GBD-121-2 D.30 RESP95 K-58 1 P43690 K0581-01 GBD1213-E2 F.W.5A EXIT ELBOW X-49 20 FW 9 TB 10 7 I 0 T-217 9.23 8 2'N14-4'WM

.812.541 X-RIOB GBD-12'1-3 D.30 RESP95 K-582 P4369 I K0582-01 GBD1214-E2 ELBOW X-60 20 FW" 10 TB 10 710 T-213 3.32 8 1'S20-'13 lWM 0.812 GBD-12 1-4 K-583 P43692 0.541 K0583-O'I X-RIOB E NUMBER 6 UNIT 1-BRIO--EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE SIZE ELEV GRID ROOM ERATE INSUL MIN WALL EWRNUM ISI ISO MEAS MIN ACTIVITY NO COMMENTS GBD1081-E3 REJECT TO CST VALVE X-219 COND 9 658 T-52 3'N16-5'EK TB 0.00 0 8 EXM SCH.237.157 X-RIOB OUT DTE GBD-108-1 D.65 RESP95 K-573 F43684 K0573-01 GBD108'I-E4A REDUCER REJECT TO CST, BOTH SIDES OF VALVE Z 1-0BS X-220A 12 COND 10 TB 658 T-52 00.00 10'N17-4'EK 0.500 GBD-108-1 K52 F43641.333 0.65 K0052-01 X-RIOB RESP95 GBD1081-E48 REDUCER REJECT TO CST~BOTH SIDE OF VALVE Z 1-08S X-2208 COND'10 TB 658 T-52 00.00 10'N17-4'K 8.322 GBD-108-1 K52 P43641.215 D.65 K0052-01 X" R IOB RESP95 GB01091-E3 SHORT PATH HAND GRID REDUCER X-137 14 COND 7 TB 0 678 T-113 36.52 8 4524-15WK F 500 GBD-109-1 K53 F43642.333 0.66 K0053-01 X-RIOB RESP95 GBD1 131-El ORIFICE LONGPATH AFTER HV-10570 X-139 16 FW 7 TB 9.656 GBD-113-1 K-5?4 F43685 668 T-36 25.11 8.437 D.23 6'N24-17'EHB K0574-OI X-R IOB RESP95 GBD1131-E2 45 ELBOW LONG PATH AFTER FO-105708 Z 1-OBS X-37 16 FW 7 TB 15 718 T-211 35.15 8 6'N24-9'WJC

.656.437 X-RIOB GBD-1 13-1 D.23 RESP95 K54 K0054-Ol P43643 GB01131-E3 ORIFICE LONG PATH AFTER FO-10570A X-46 16 FW 7 TB 15 718 T-21 I 13.69 8 5'N24-14'WK

.656 GBD-113-1 K-575 P43686.437 0.23 K0575-01 X-RI 08 RESP95 AGE NUMBER 8 UNIT 1-BRIO--EROSION/CORROSION EXAMS (SORTED BY PRIORITY)REPORT DATE: 06/28/95 REPORT 2 COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS GBD1215-E2 R.W.5C EXIT Z 1-TEMP DESCRIPTION 90 EI.BOW REPLCO ID X-64 SIZE 20 ELEV ROOM ERATE INSUL MIN WALL ISI ISO GRID FW ll 710 T-213 4'N22-0'8LA TB 44.64 8 8 EWRNUM EXM SCH.812.54 I MEAS MIN OUT DTE GBD-'I21-5 D.30 SYSTEM AREA BUILD SCAFF NOM WALL LINE ACTIVITY NO K62 K0062-01 P43644 MAP NO.WA NO X-RIOB RESP95 GBDI252-E1A HAND GRID TEE F X-482A MCPR lo TB 734 T-422 12.5 1'N15-2'WL 0 0.237 GBO-125-2 K147 P43655 C.157 K0147-01 X-RIOB RESP95 GBD1252-E I 8 HAND GRID TEE F X-4828 MCPR 10 TB 0 734 T-422 47.6 C 1'15-2'WL.250 GBD-I25-2 K147 P43655.166 M59208 K0147-0 1 X-RIOB RESP95 GBD1261-El VALVE OEMIN RECYCLE TO CONDENSER HV-11617 X-218 CDEM 12 TB 8.322 GBO-126-1 K-584 P43693 668 T-42 57.94 8.215 D.1 11 4'S24-8'EN K0584-01 X-RIOB RESP95 GBD 1401-E2 FWH 4A VENT ELBOW X-32 FW 9 TB 706 T-215 2.0 6'N15-10'K 5.300 GBD-140-1 K-585 P43694 8.200 0-18 M59241 K0585-0 I X-RIOB RESP95 GFD1012-E3 EXTR TO FWH 58, C ELBOW X-9 14 EXTST 6 TB 20 718 T-211 24.8 8 3'N17-O'WHB

.375.250 X-RIOB GFD-10 I-2 0.2 RESP95 K-586 P43695 K0586-01 GFD1012-E4 PIPE EXTR TO FWH 58, C X-8 14 EXTST 6 TB 725 T-2ll 38.4 3'N17-O'WHB 20.375 GFD-10'I-2 K-587 P43696 8.250 0.2 K0587-0 I X-RIOB RESP95

Al E NUMBER 9 UNIT I-BRIO--EROSION/CORROSIOh EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCO ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE COMMENTS G F01013" E2 PIPE X-863 16 GRID EXTST 9 709 T-215 9'16-16'L TB 28.0 7 8 EWRNUM EXM SCH.0375.250 X-RIOB MEAS MIN OUT DTE GFD 101-3 RESP95 ACTIVITY NO K-595 F43761 K0595-Ol GF01014-E3 PIPE X-864 EXTST 10 TB 708 T-214 12.0 9'18-16'L 6.375 B.250 GFD101-4 X RIOB RESP95 K-596 P43762 K0596-Ol GFD1015-E2 PIPE X-865 16 EXTST'll TB 5 706 T-212 00.00 B 9'N24-16'EL

.375.250 X-RIOB GFD101-5 RESP95 K-597 P43763 K0597-OI HAD1021-E2 DRAIN 3A TO 2A TEE 8 X-1 14 FW 6 TB 4 707 T-211 14.89 8 5'19-0'8JB.375 HAD-I02-I-E2 K550 P43739.328 D.l K0550-01 X-RIOB RESP95 HBD1061-E2 ORIFICE MSV STEAM LEAKOFF FE-10104 X-85 TS 6 TB 4 707 T-211 27.65 8 2'S17-5'EHB

.280.186 X-RIOB HBD-106-'I 0.42 RESP95 K-589 P43697 K0589"01 HBD1071-El HAND GRID 45 EI.BOW X-847 24 EXTST 6 TB I 6 719 HPCON 49.6 6'S19-6'EHB

.375.250 X-RIOB HBD-107-1 RESP95 K-510 P43624 K0510-01<<601071-E2 HAND GRID PIPE X-846 24 EXTST 6 TB 18 721 HPCON 44.80 6'S19-6'EHB

.375.250 HBD-107-1 X-RIOB RESP95 K-511 P43625 K051 1-01 GE NUMBER'IO UNIT 1-BRIO--EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE COMMENTS HBD1071-E3 Z1, Z2 TEMP 90 ELBOW X-825 SIZE 24 ELEV GRID EXTST 6 717 HPCON 6'SI9-3'EHB TB 90.4 15 ROOM ERATE INSUL MIN WALL EWRNUM EXM SCH.375.250 M59234 X-RIOB ISI ISO MEAS MIN OUT DTE HBDI07-1 RESP95 ACTIVITY NO K-512 P43626 K0512-0 I HBD10710-E1 HAND GRID 45 ELBOW X-859 24 EXTST 3 TB 719 LPCON 49.6 5'S23-6'WHB 16.375 HBD-107-10 K-539 P43728.250 K0539-01 X-RIOB HBD 10710-52 HAND GRID PIPE X-858 24 EXTST 3 TB 721 LPCON 36.8 5'$23-6'WHB 18.375 HBD-107-10 K-540 P43729.250 K0540-01 X-RIOB HBD10710-E3 90 ELBOW X-838 24" EXTST 3 TB 717 LPCON 45.6 3'S23-3'WHB 15.375 HBD107-10 K-541 P43730.250 K0541-01 X-RIOB H801071'I-E1 HAND GRID PIPE X-862 24 EXTST 7 TB 18.375 HBD-107-11 K-542 P43731 721 LPCON.250 7'N23-6'EHB K0542-OI X-RIOB HBD107 1 1-52 HAND GRID 45 ELBOW X-821 24 EXTST 7 TB 719 LPCON 88.8 7'N23-6'EHB 16.375 HBD-107-11 K-543 P43732.250 M59232 K0543-01 X-R IOB RESP95 HB01071 1-E3 90 ELBOW X-840 24" EXTST 7 TB 718 LPCON 98.4 7'N23-8'EHB 15.375 HBD107-1 I K-544 P43733.250 M59233 K0544-01 X-RIOB RESP95 AGE NUMBER 11 UNIT 1-BRIO--EROSION/CORROSIOn EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT OATEz 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE COMMENTS HBD1071 1-54 90 ELBOW X-841 2 4 lt GRID EXTST 7 713 LPCON 4'S23-10'EHB TB 190.4 EWRNUM EXM SCH 10.375.250 M59225 X-R IOB MEA5 MIN OUT DTE HBD107-1 I RESP95 ACTIVITY NO K-545 F43734 K0545-0 I HBD 10712-E1 HAND GRID PIPE X-856 24 EXTST 3 TB 18.375 HBD-107-12 K-546 P43735 721 LPCON 30.4.250 7'N23-6'WHB K0546-01 X-RIOB HBD10712-E2 HAND GRID 45 ELBOW X-857 24 EXTST 3 TB 719 LPCON 167.2 7'N23-6'WHB 16.375 HBD-107-12 K-547 P43736.250 M59223 K0547-01 X-RIOB RESP95 HBD10712-E3 90 ELBOW X-836 24 N EXTST 3 TB 718 LPCON 49.60 7'N23-8'WHB 15.375 HBD107-12 K-548 P43737.250 K0548-01 X-RIOB'ESP95 HBD107 12-E4 90 ELBOW X-837 24" EXTST 3 TB 10 713 LPCON 168.0 4'523-'10'WHB

~375.250 M59226 X-RIOB HBD 107-12 RESP95 K-549 P43738 K0549-0 I H801072-EI HAND GRID 45 ELBOW X-845.24 EXTST 2 TB'16 719 HPCON 63.2 7'S19-6'WHB

.375 HBD-107-2 K-5 13 P43702.250 M59216 K0513-01 X-RIOB RESP95 HBD1072-E2 HAND GRID PIPE X-844 24 EXTST 2 TB 721 HPCON 49.6 7'S19-6'WHB 18.375.250 HBD-107-2 X-RIOB RESP95 K-5 14 P43703 K0514-01

GE NUMBER 12 UNIT I-BRIO--EROSION/CORROSIOn EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE COMMENTS HBD1072-E3 90 ELBOW X-824 24" GRID EXTST 2 717 HPCON 6'19-3'WHB TB 118.4 EWRNUM EXM SCH 15.375.250 M59213 X-RIOB MEAS MIN OUT DTE HBOI07-2 RESP95 ACTIVITY NO K"5 15 P43704 K0515-01 HBD1073-El HAND GRID PIPE X-848 24 EXTST 6 TB 721 HPCON 47.2 5'N19-6'EHB 18.375 HBD-'107-3 K-516 P43705.250 K0516-01 X-RIOB RESP95 HBD1073-E2 HAND GRID 45 ELBOW X-849 24 EXTST 6 TB 719 HPCON 23.2 5'N19-6'EHB 16.375.250 HBD-107-3 K-517 P43706 K0517-01 X-RIOB RESP95 HBDI073-E3 90 ELBOW X-826 24'XTST 6 TB 7 17 HPCON 98.4 5'N19-8'EHB

'15.375.250 M59218 X-RI 08 HBD107-3 RESP95 K-5'IB P43707 K0518-01 HBD1073-E4 90 ELBOW X-827 24'XTST 6 TB 10 712 HPCON 100.0 6'519-10'EHB

.375 HBO107-3.250 M59214 X-RI 08 RESP95 K-5'19 P43708 K0519-01 HBD1074-El TEMP PIPE X-842 24 EXTST 2 TB 18.375 HBD-107-4 K-520 F43709 721 HPCON 48.8.250 5'N19-6'WHB K0520-01 X-RIOB RESP95 HBD1074-E2 Zl, Z2 TEMP 45 ELBOW X-843 24 EXTST 2 TB 719 HPCON 29.6 5'N19-6'WHB RESP95 16.375 HBO-107-4 K-521 P43710.250 K0521-01 X-RIOB

PAfiE NUMBER 13 UNIT 1-BRIO--EROSION/CORROSIOh EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE SIZE f LEV GRID ROOM ERATE INSUL MIN WALL EWRNUM ISI ISO MEAS MIN ACTIVITY NO COMMENTS HB01074-E3 90 ELBOW X-822 24 II EXTST 2 TB 15 717 HPCON 77.6 5'NI9-8'WHB EXM SCH.375.250 M59220 X-RIQB OUT DTE HBD107-4 RESP95 K-522 P43?11 K0522-01 HBD1074-E4 90 ELBOW X-823 24" EXTST 2 TB 10 7 12 HP CON 102.4 6'19-10WHB.375 HB0107-4 K-523 P43712.250 M59215 K0523-01 X-RIOB RESP95 H801075-E1 HAND GRID 45 ELBOW X-829 24 EXTST 7 TB 16 7'19 IPCON'104.8 6'S2 1-6'EHB.375 HBD-107-5 K224 P43622.250 M59230 K0224-01 X-RIOB RESP95 HBD1075-E2 HAND GRID X-854 24 EXTST 7 TB IB 721 IPCON 41.6 6'S2'1-6'EHB

.375.250 HBD-107-5 K-524 P43713 K0524-01 X-RIOB RESP95 HBD1075-E3 90 ELBOW X-832 24'XTST 7 TB 717 IPCON 57.6 4'S21-3'EHB HBD107-5 15.375.250 M59227 X-RIOB RESP95 K-525 P43714 K0525-01 HBD1076-E1 HAND GRID 45 ELBOW X-853 24 EXTST 3 TB 719 IPCON 73.6 6'S21-6'WHB 16.375 HBD-107-6 K-526 P43715.250 M59229 K0526-01 X-R IOB RESP95 HBD1076-E2 HAND GRID PIPE X-852 24 EXTST 3 TB 721 IPCON 31.2 6'521-6'WHB IB.375.250 HBD-107-6 X-RI 08 RESP95 K-527 F43716 K0527-01 PARE NUMBER 14 UNIT 1-BRIO-EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE COMMENTS HBD1076-E3 90 ELBOW X-831 SIZE 24" ELEV GRID EXTST 3 717 IPCON 4'S21-3'WHB TB 70.40 ROOM ERATE INSUL MIN WALL EWRNUM EXM SCH.375.250 M59221 X-RIOB ISI ISO MEAS MIN OUT DTE HBD107-6 RESP95 ACTIVITY NO K-528 P43717 K0528-01 HBD 1077-E1 HAND GRID PIPE X-833 24 EXTST 7 TB 721 IPCON 48.0 6'N21-6'EHB 18.375.250-X-RIOB HBD-107-7 RESP95 K225 K0225-01 P43623 HBD1077-E2 HAND GRID 45 ELBOW X-855 24 EXTST 7 TB'16.375 HBD107-7 719 IPCON 49.6.250 6'N21-6'EHB X-RIOB RESP95 K-529 F437'IB K0529-01 HBD'1077-E3 90 ELBOW X-834 24'XTST 7 TB 15.375 HBD107-7 718 IPCON 69.6.250 6'N21-8'EHB M59231 X-RIOB RESP95 K-530 P43719 K0530-01 HBDI077-E4 90 ELBOW X-835 24" EXTST 7 TB 10 713 IPCON 204.8 5'2 1-10'HB.375.250 M59228 X-RIOB HBD107-7 RESP95 K-53 1 P43720 K053'1-01 HBD1078-E1 HAND GRID PIPE X-850 24 EXTST 3 TB 18.375 HBD107-8 K-532 P43721 721 IPCON 40.8.250 6'N2 1-6'WHB K0532-OI X-RIOB RESP95 H801078-E2 HAND GRID 45 ELBOW X-851 24 EXTST 3 TB.16.375 HBD-107-8 K-533 F43722 719 IPCON 57.6.250 6'N21-6'WHB M59219 K0533-01 X-R I 08 RESP95 iE NUMBER 15 UNIT 1-BRIO-EROSION/CORROSIOtc FXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE COMMENTS HBD1078-E3 90 ELBOW X-828 24 ol GRID EXTST 3 717 IPCON 6'2 1-8'HB TB 47.2 15 EWRNUM EXM SCH.375.250 X-R IOB MEAS MIN OUT DTE HBD 107-8 RESP95 ACTIVITY NO K-534 P43723 K0534"0 I HBD1078-E4 90 ELBOW X-830 24'XTST 3 TB'10 7 12 IPCON 112.8 5'S21-10'WHB

.375.250 M59235 X-RIOB HBD107-8 RESP95 K-535 P43724 K0535-01 HBD1079-E1 HAND GRID 45 ELBOW X-861 24 EXTST 7 TB 16 719 LPCON 120.0 5'S23-6'EHB

~375.250 M59224 X-R IOB HBD-107-9 RESP95 K-536 P43725 K0536-01 HBD1079-E2 HAND GRID PIPE X-860 24 EXTST 7 TB 18 721 LPCON 40.8 5'S23-6'EHB

.375.250 X-RIOB HBD-107-9 RESP95 K-537 P43726 K0537-01 HBD1079-E3 90 ELBOW X-839 24 M EXTST 7 TB 717 LPCON 48.8 3'S23-3'EHB 15.375.250 HBD 107-9 K-538 P43727 K0538-01 X"RIOB RESP95 HBD 1 081-E1 EXTR TO FWH 4C TEE A X-15 24 EXTST 2 TB 12 717 HPCON 00.00 3N19-5'"WHB.375.250 X-RIOB HF D-1 08-'I D.6 RESP95 K64 K0064-01 P43646 HBD108 I-E2 45 ELBOW SIS: X-257,260,261,264,265 X-256 16 EXTST 2 TB 15 720 HPCON 00.00 3'5 19-5'WHB.375.250 X-RIOB HBD-108-I D.6 RESP95 K65 P43647 K0065-01 iE NUMBER 16 UNIT 1-BRIO--EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WAI.L LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN ACTIVITY NO COMMENTS HBD 109 1-E 10 45 ELBOW X-709 26 EXTST 6 712 T-211 4'516-5'WJC TB 0.0 10 8 EXM SCH 0.375 0.250 X-RIOB OUT DTE HBD 109-1 HBD 109-1 RESP95 K0006-O'I P43628 HBD1093-EB Z1, Z3 TEMP 90 ELBOW X-728 26 EXTST 7 TB 712 T-211 3.2 4521-1'I WK 10 0.375 HBD109-3 K32 F43629 8 0.250 HBD109-3 K0032-Oi X-RIOB RESP95 HBDI093-E9 ZI-TEMP 90 ELBOW X"729 26 EXTST 7 TB 10 712 T-211 41.60 8 9N24-1 1WK 0.375 0.250 X-RIOB HBD109-3 HBD 109-3 RESP95 K33 K0033-01 P43630 HBD1094-E1 ELBOW 90 X-735 20 EXTST 6 TB 12 0.375 714 T-211 21.6 8 0.250 2'N 19-10'WK X-RIOB HBD 109-4 HBD 109-4 RESP95 K556 K0556-01 P43667 HBD1 141-E2 FWH 2A VENT ELBOW X-34 FW 2 TB 0 704 T-211 22.22 8 7'5 18-3'EGB.216.144 X-RIOB HBD-114-1-D.20 RESP95 K-590 P43698 K0590-01 HBD1212-E4A TEE 8 COND.PUMP A INLET (MAIN)X-56A 48 COND 8 649 T-31 2'N25-5'WK TB 0'375 HBD-121-2 6.4'-.250 D.36 X-RIOB RESP95 K-591 P43699 K0591-01 HBD1212-E48 TEE D COND.PUMP A INLET (BRANCH)X-568 30 COND 8 649 T-31 2'N25-5'WK TB 7.20 0.375 HBD-12'I-2.250 D.36 X-RIOB RESP95 K-591 P43699 K0591-01 AGE NUMBER 17 UNIT 1-BRIO--EROSION/CORROSION EXAMS (SORTED BY PRIORITY)REPORT DATE: 06/28/95 REPORT 2 DESCRIPTION COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS HBD1542-E3 90 ELBOW HP TURB INNER GLAND LKOFF Z 1"TEMP REPLCD ID X-166 SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN TS 6 726 T-211 4'5"N18-O'HB TB 31.25 22 8 EXM SCH.237.157 OUT DTE HBD-154-2 D.79 SYSTEM AREA BUILD SCAFF NOM WALL LINE ACTIVITY NO K89 K0089-01 P43648 MAP NO.WA NO X-RIOB RESP95 HBD'1662-EI ELBOW EXTR.STEAM TO SSE X-159 TS 9 TB 8 738 T-416 11.21 8 8'16-1 I'WM.322.215 X-RIOB HBD-166-2 D.76 RESP95 K-592 F43700 K0592-O'I HBD1681-E3 Z 1-TEMP 45 ELBOW X-816 SSE 2 TB 15 695 T-1'13 24.05 8 6'S17-3'WHB

.237.157 X-RIOB HBD168-1 HBD 168-I RESP95 K211 K0211-01 P43620 SPEBD1112-El 90 ELBOW RFPT 8 HP BEFORE SEAT DRAIN X-186 RFPT 7 TB 12 670 T-36'18.48 8 6'N21-12'WK

.358 SP-EBD-111-2 K-598 P43764.239 D.86 K0598-OI X-RIOB RESP95 SPEBD1112-E2 ORIFICE X-'185 RFPT 8 HP BEFORE SEAT DRAIN FO-127128 RFPT 7 670 T-36 6'N21-11'WK TB 12.358 SP-EBD-1 1 1-2 K-599 P43765 21~84 8.239 D.86 K0599-01 X-RIOB RESP95 SPEBD11'15-EI 90 ELBOW RFPT A HP BEFORE SEAT DRAIN AMERTAP IMPACT X-184 RFPT 6 670 T-36 6'S18-12'WK TB 12.358 12.6 8.239 X-R I 08 SP-EBD-111-5 K-600 P43766 D.85 K0600-01 RESP95 SPEBD I 143-E 1 90 ELBOW RCIC STEAM LINE DRAIN EXISTING GRID X-'133 RCIC 25 WING 4.358 SP-EBD-114-3 K215 P43621 723 R-4 11 36.66 8.238 D.62 10'S23.5-10WP K0215-01 X-RIOB RESP95 llfiE NUMBER 18 UNIT 1-BRIO--EROSION/CORROSIOh EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS SPGAD1382"E2 ORIFICE BYPASS STEAM LINE DRN FO-'IOIOB Z I-TEMP REPLCD ID X-92 SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN BPS 2 689 T-I 13 15'N19-13'EG TB 16.86 9 8 EXM SCH.250.167 X-RIOB OUT DTE SP-GAD-138-2 0.45 RESP95 SYSTEM AREA BUILD SCAFF NOM WALL LINE ACTIVITY NO K157 K0 157-01 P43660 MAP NO.WA NO SPGAD1443-E12 ELBOW MAIN STEAM AFTER CV DRAINS X-124 TURB 2 TB 0 678 T-128 26.95 8 4'NIB-4'EHB

.344.229 X-RIOB SP-GAD-144-3 K-601 P43767 D.57 K0601-01 RESP95 SPGBD1041-5 I FWH 5C VENT 90 ELBOW X-182 FW 11 TB 0 703 T-212 20.00 8 5'N23-2'ELA

.300.200 X-RIOB SPGBD-104-1 D.84 RESP95 K-602 P43768 K0602-01 SPGBD1042-El FWH SA VENT HAND GRID 90 BEND X-181 FW 9 TB 0 704 T-215 49.56 8 4'N15-12'WM

.344.229 X-RIOB SPGBD-104-2 K 158 P43 661 0.83 K0158-01 RESP95 SPGBD1254-El VALVE AUX SEAL STEAM SUPPLY DRAIN HAND GRID INCLUDE BEND W/VALVE X-206 MCPR 9 TB 0 733 T-416 73.80 8 2'N15-I'WL.250.166 M59207 X-RIOB SP-GBD-125-4 K170 P43598 D.99 K0170-01 RESP95 SPGBD1281-E I SIS: X-675, 676 ORIFICE X-674 FW 9 TB 8 710 T-215 13.91 8 2'515-8'WM

.344 SP-GBD-128-1 K-160 P43662.229 D.194 K0160-01 X-RI 08 RESP95 SPGBD I 282-E I SIS: X-674, 675 ORIFICE X-676 FW ll TB 0.344 SP-GBD-128-2 K-603 P43769 706 T-212 27.82 8.229 D.196 9'N24-6'WM K0603-0 I X-RIOB RESP95 AGE NUMBER 19 UNIT 1-BRIO--EROSION/CORRO N EXAMS (SORTED BY PRIORITY)REPORT DATE: 06/28/95 REPORT 2 COMPONENT ID OESCR I PTI ON REPLCD IO SYSTEM AREA BUILD SCAFF NOM WALl LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN ACTIVITY NO COMMENTS SPGBD1287-E1 SIS: X-674, 676 ORIFICE X-675 FW IO 706 T-214 9'S18"6'WM TB 19.13 0 8 EXM SCH.344.229 X-RIOB OUT DTE SP-GBD-128-7 D.195 RESP95 K-604 K0604-01 P43770 SPGBD13318-E1 ELBOW RFPT A LP BELOW SEAT DRAINS X-132 RFPT 10 TB 0 682 T-116 31.32 8 7'S19-10'EK

.250.167 X-RIOB SPGBD-133-18 K-181 P43603 D.6'I K0181-01 RESP95 SPG8013319-E1 A RFPT CHEST DRAIN HAND GRID 90 ELBOW X-2 12.75 RFPT 10 TB 0 681 T-116 31.08 8 2'S19"9'EK

.219.145 X-RIOB SPGBD-133-19 K182 P43604 D.105 K0182-01 RESP95 SPGB013321-Ei C RFPT CHEST DRAIN HAND GRID 90 ELBOW X-214.75 RFPT 1'I TB 0.219 68'I T-114 31.08 8.145 1'N23-8'EK X-RIOB SPGBD-133-21 K'183 P43605 D.107 KO'I 83-0 I RESP95 SPGBD13322-E1 90 ELBOW B RFPT CHEST DRAIN HAND GRID X-213.75 RFPT 11 TB 0 681 T-115 9.45 8 O'S21-9'EK

.219.145 X-R I 08 SPGBD-133-22 K184 P43606 D.106 K0184-01 RESP95 SPGBDI339-E1 90ELBOW 8 RFPT LP BEFORE SEAT DRAIN X-2 10 RFPT 11 TB 0 682 T-115 26.5 8 6'S21-10'EK

.250.167 X-RIOB SP-GBD-133-9 K-605 P43771 D.103 K0605-01 RESP95 SPGBD1441-E1 ELBOW MSV BEFORE SEAT DRAINS X-121 TURB 6 671 T-36 9'N19-O'WJC TB 12.344 SP-GBD-144-1 K-606 P43772 27.82 8.229 D.56 K0606-01 X-RIOB RESP95 GE NUMBER 20 UNIT 1-BRIO--EROSION/CORROSIOa EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS SPGBO1442-E4 VALVE MSV A BEFORE SEAT DR HV-10101A-D REPLCD ID X-120 SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO GRID TURB 6 TB 4 706 T-21)26.5 8 12'N)7-17'WK EWRNUM EXM SCH.250.167, MEAS MIN OUT DTE SP-GBD-144-2 0.56 SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO ACTIVITY NO K607 P43773 K0607-OI X-R IOB RESP95 SPGBD1521-E1 ELBOW MAIN STEAM TO RFPT DRAINS X-130 RFPT 7 670 T-36 7'N23-7'EJ TB'10 31.32 8.250.)67 X-RIOB SP-GBD-152-1 0.28 RESP95 K-608 P43774 K0608-01 SPGBD)521-E3 RFPT C MN STM DRAIN HAND GRID BEND X-43 RFPT 11 TB 0.250 SP-GBD-152-)

K185 P43607 679 T-114 20.48 8.167 D.28 9'N23-Ii'EK Ko)85-01 X-RIOB RESP95 SPGFD1026-E2 VALVE XAROUND STM RFPT HDR OR)-27-005 X-106 1.5 RFPT 7 TB 0 682 T-113 27.65 8 I'N22-3'WK

.28).187 X-RIOB SP-GFD-102-6 K-)87 P43608 D.25 KO)87-0)RESP95 SPHAD)0731-El 90 ELBOW RFPT 8 XAROUND STEAM DRAIN Zl-HAND GRID X-39 RFPT 11 TB 0 680 T-115 24.5 8 9'S21-2'EK

.218.145 X-R IOB SPHAD-1073-1 K174 P4360)D.25 KO)74-01 RESP95 SPHAD10731-E2 ELBOW RFPT XAROUND HDR DRAIN X-41 RFPT 7 TB 13 673 T-36 19.17 8 3'N22-3'WK

.218.)45 X-RIOB SPHAD-1073-1 K-609 P43775 D.25 K0609-O'I RESP95 SPHAO)691-E2 90 ELBOW SSE-BLOWOOWN HV-)0761 HAND GRID X-1 19 TS 2 TB 0 681 T-)13 35 8 2'S18-3'WHB

.179 SP-HAD-169-1 K175 P43602.1)9 D.55 K0175-01 X-RIOB RESP95 GE NUMBER 21 UNIT 1-BRIO-EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS SPHBD10051-E 1 ELBOW STEAM SEAL HEADER DRAIN REPLCD ID X-161 SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN TS 6 703 T-211 9'N19-5'EHE TB 16.16 2 8 EXM SCH.179.119 OUT DTE SPHBD-1005-I D.77 SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO ACTIVITY NO K-610 P43776 K0610-01 X-RIOB RESP95 SPHBD10051-E2 ORIFICE STEAM SEAL HEADER DRN FO-10722 X-160 TS 6 TB 5 706 T-21 1 16.66 8 10'N18-3'EHE

.179.1'19 X-RIOB SPHBD-1005-1 K-611 P43777 D.77 K061 1-0 I RESP95 SPHBD10721-E I 90 ELBOW RFPT C XAROUND DRAIN Z I-TEMP X-40 RFPT 7 TB 0 680 T-1'14 35.61 8 8'523-2'EK

.218.145 X-RIOB SPHBD-1072-1 K190 P43609 D.26 K0190-0 I RESP95 SPHBD10851-E2A REDUCER C RFPT 1ST STAGE DRAIN X-215A RFPT 7 669 T-36 8'S22-12'WK TB 11.200 SPHBD-1085-1 K-612 P43778 0.0 8.133 D.108 K0612-01 X-RIOB RESP95 SPHBD 10851-E28 REDUCER C RFPT 1ST STAGE DRAIN X-2158 1.25 RFPT 7 TB 669 T-36 0.0 8'S22-12'WK 11.191 SPHBD-1085-1 K-612 P43778 8.127 D.108 K0612-0 I X-R I 08 RESP95 SPHBD 1 091-E1 EXTRACTION 3A DRAIN 90 ELBOW X-204 EXTST 6 TB 7 706 T-21'I 24.65 8 2'N19-8'EHE

.218 SP-HBD-109-1 K-613 P43779.190 0.97 K0613-01 X-RIOB RESP95 SPH801091-E2 VALVE EXTRACTION 3A DRAIN HV-'10203A Zi-TEMP X-203 EXTST 6 TB 4 706 T-211 39.72 8 1'18-8'HE.218.145 X-RIOB SP-HBD-109-1 K161 P43663 D.97 K0161-01 RESP95

GE NUMBER 22 UNIT I-BRIO--EROSION/CORROSIOn EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE?06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN ACTIVITY NO COMMENTS SPHBD'1092-El EXTRACTION 3C DRAIN 90 ELBOW X-205 EXTST 7 701 T-211 4'N23-2'WHE TB 41.09 0 8 EXM SCH.218.190 X-RIOB OUT DTE SP-HBD-109-2 0.98 RESP95 K-614 P43780 K0614-01 SPHBD1104-E2 EXTRACTION 4C DRAIN Z I-TEMP 90 ELBOW X-198 EXTST 7 TB 5 708 T-21'I 26.03 8~9'N23-10'EHE

.218.145 X-RIOB SP-HBD-I 10-4 K 165 P43664 D.92 K0165-01 RESP95 SPHBD1105-E2 90 ELBOW EXTR 4C DRAIN (IBC)Z I-TEMP X-28 EXTST 7 TB 5 708 T-211 30.13 8 9'N24-4'WK

.218 SP-HBD-110-5 K166 P43665.145 D.14 K0166-01 X-RIOB RESP95 SPHB01107-El EXTRACTION 48 DRAIN Zl, Z3 TEMP 90 ELBOW X-200 EXTST 6 TB 6 710 T-211 35.62 8 6'N19-4'WK

.2'IB.'145 X-RIOB SP-HBD-110-7 K167 P43666 0.94 K0167-0 I RESP95 SPHBD1108-E2 EXTR 48 DRAIN (058)Zl-TEMP 90 ELBOW X-27 EXTST 7 TB 12.218 SP-HBD-110-8 K168 F43597 7 14 T-2'll 89.04 8.145 D.13'7'21-10'HE M59222 K0 168-01 X-RIOB RESP95 SPHBD1185-El SIS?NONE OAIF ICE X-611 RFPT 5 TB 8.179 SP-HBD-118-5 K-615 P43781 686 T-113 15.00 8.I19 D.161 8'S15-10'WK K0615-0 I X-RIOB RESP95 SPHB01391-E I VALVE AFP DISCHARGE RELIEF VALVES X-2 16 FW 3 TB I I.179 670 T-36 0.0 8.119 7'N21-4'EGA X-R IOB SP-HBD-139-

'I K-616 F43782 D.109 K0616-01 RESP95

AfiE NUMBER 23 UNIT 1-BRIO--EROSION/CORROSION EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 DESCRIPTION COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS SPHBD148 I-E 1 BEND MAIN STEAM TO SJAE DRN HAND GRID REPLCD ID X-I 02 SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN MCPR 2 680 T-113 4'N18-5'WHB TB 33.35 0 8 EXM SCH.I79.1I9 OUT DTE SP-HBD-148-1 D.49 SYSTEM AREA BUILD SCAFF NOM WALL LINE ACTIVITY NO K171 K0171-0 I P43599 MAP NO.WA NO X-RIOB RESP95 SPHBD1483-E 1 VALVE MAIN STEAM TO SJAE DRN 1-07-054 HAND GRID OBS X-100 MCPR 2 TB 0 681 T-113 26.6 8 4'N18-9'WHB

.179.119 X-RIOB SP-HBD-148-3 K I 73 F43600 D.49 K0173-0 I RESP95 SPHBD 1711-El VAI VE SSE VENT AFTER HV-10728 X-116 TS 6 TB 7 686 T-113 3'1.67 8 10'N18-4'EHB

.179.119 X-R IOB SP-HBD-171-1 0.54 RESP95 K553 K0553-01 P43740 SPHBD1713" E I ORIFICE SSE VENT AFTER FO-10728 X-1 I5 TS 9 TB 0.179 SP"HBD-I71-3 K554 F4374 I 729 T-4I6 18.33 8.119 D.54 6'N16-5'EL K0554-01 X-RI 08 RESP95 SPHBD302310-Ei SIS: NONE HAND GRID BEND X-634 1.5 AUX BLR 9 669 T-52 4'S I5-12'EL TB 10.200 113.4 8.133 M59211 X-RIOB SPH803023-10 D.184 RESP95 K200 F436'15 K0200-OI SPHBD302312-E 1 SIS: NONE HAND GRID 90 ELBOW X-635.75 AUX BLR 9 672 T-52 4'SI5-7'EK TB 14.'154 SPHBD3023-'12 K201 F43616 35.29 8.I03 D.184 K0201-0 I X-RI 08 RESP95 SPHBD3023I9-EI SIS: NONE HAND GRID 90 ELBOW X-632 AUX BLR 23 TB 10.179 669 T-51 25.0 8.119 4'S40-l4'WM X-RIOB SPHBD3023-19 K202 F43617 D.183 K0202"01 RESP95 PAGE NUMBER 24 UNIT 1-BRIO-EROSION/CORROSION FXAMS-REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DETAIL PLAN ACC 2 LINE COMMENTS SPHB030234-EI SISz NONE HAND GRID DES CRI PTION 90 ELBOW REPLCD ID X-636 SIZE 1.5 ELEV GRID ROOM ERATE INSUL MIN WALL EWRNUM EXM SCH AUX BI.R 5 669 T-44 3'N14-2'WJB TB 35.82 10 8.200.133 X-RIOB SYSTEM AREA BUILD SCAFF NOM WALL LINE ISI ISO MEAS MIN OUT DTE SPHBD3023-4 D.184 RESP95 MAP NO.WA NO ACTIVITY NO K 197 P43612 K0197-01 SPHBD30234-E2 S IS: NONE HAND GRID BEND X-637 AUX BLR 5 TB 8 711 T-217 47.46 8 10'N15-3'WJB

.200 SPHBD3023-4 K'198 F43613.133 D.184 M59212 KO 198-01 X-RIOB RESP95 SPHBD30234-E3 SI 5: NONE HAND GRID 90 ELBOW X-638 1.5 AUX BI.R 5 TB 8 711 T-217 53.73 8 4'S14-6'WJB

.200.133 M59205 X-RIOB SPHBD3023-4 K199 F43614 D.184 K0 199-01 RESP95 SPHC01041-E4 SIS: X-624 VALVE X-622 CRD 11 TB 0 661 T-52 27.27 8 5'S24-0'8KC

.133 SP-HCD-104-1 K-617 F43783.089 D.133 K0617-01 X-RIOB RESP95 SSH-E3A SSE OUTLET REDUCER X 187A 12 TS 9 TB 8.406 SSH 741 T-416 36.76 8.270 0.87 6'N15-I'EL X-RIOB RESP95 K-593 P43701 K0593-Oi SSH-E38 SSE OUTLET REDUCER X-1878 8 TS 9 TB 8.322 SSH 741 T-416 0.0 8.214 0.87 6'N15-1'EL X-R IOB RESP95 K-593 P4370 I K0593-01 VNBB211-E1 MS LINE C Zi 8 Z2-HAND GRID 90 ELBOW X-459 26 MS 26 RB 15 787 R-516 40.75 M 252 AZ-19-RCL 1.138.893 X-RI 08 VNBB-21 1-1 D.B I RESP95 K148 K0 148-01 F43656 GE NUMBER 25 UNIT 1-BRIO--EROSION/CORROSION EXAMS-REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE SIZE ELEV GRID ROOM ERATE INSUL MIN WALL ISI ISO EWRNUM MEAS MIN ACTIVITY NO COMMENTS VN88211-E3 SI S: X-174, 460, 462 Zl, Z2 TEMP 45 ELBOW X-460 26 MS 26 750 R" 516 288AZ-26RCL RB 33.20 10 M EXM SCH 1.138.893 X-RIOB OUT DTE VN88211-1 D.150 RESP95 K 149 K0 149-01 F43657 VNBB212-E3 90 ELBOW SIS X 174'60'64 EXISTING GRID X-462 26 MS 26 RB 0'I.138 VNBB212-1 K151 P43658 741 R-516 21.13 M.893 D.149 108AZ-28RCL K0151-01 X-R IOB RESP95 1SCVL-E12 ELBOW X-173 1.5 TS 6 TB 14 716 T-211 32.83 8 6'N18-6'WJC

.200.133 X-R I 08 1SCVL D.41 RESP95 K-557 F43668 K0557-0 I I SLCI V-E19 ELBOW CIV-CSV STEAM LEAKOFF HNAD GRID X-98 1.5 TS 6 TB 12 743 T-420 28.35 8 2'519-8'EJ

.200.133 1SLCIV 0.48 K559 F43670 K0559-01 X-RIOB RESP95 1SLCIV-E2 ELBOW SIS: X-403, 405, 407, 568, 570 X-572 TS 7 TB 0 729 T-419 29.85 8 1'23-21'G.200 1SLCIV.133 D.48 X-RIOB RESP95 K-558 P43669 K0558-01 1SSH7-E3 90 ELBOW SSE SUPPLY HEADER X-189 TS 7 TB 731 T-420 6.97 I'S22-14'EHB 21.258 1SSH-7 8.172 0.88 X-RIOB RESP95 K-560 F43671 K0560-01 1SSHB-E25A REDUCER SSE SUPPLY HEADER X-I BBA 8 TS 7 TB 21.280 1SSH-8 723 T-211 0.0 8.'186 D.BB 4'N22-O'JB X-RIOB RESP95 K-561 P43672 K0561-01 C

liE NUMBER 26 UNIT I-BRIO--EROSION/CORROSIOn EXAMS--REPORT 2 (SORTED BY PRIORITY)REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO.WA NO DETAIL PLAN ACC 2 LINE COMMENTS 1SSHB-E258 SSE SUPPLY HEADER REDUCER X1888 SIZE ELEV GRID TS 7 723 T-211 4'N22"O'JB TB 11.62 21 8 ROOM ERATE INSUL MIN WALL EWRNUM EXM SCH.258.172 X-RIOB ISI ISO MEAS MIN OUT DTE 1SSH-8 D.BB RESP95 ACTIVITY NO K-561 P43672 K0561-01 2SCVL-E13 90 ELBOW CV LP STEAM LEAKOFF HAND GRID X-90 1.5 TS 6 TB 12 715 T-211 35.82 8 6'N19-4'JC.200.133 X-RIOB 2SCVL D.41 RESP95 K194 K0194-01 P43610 2SLMSV"E22 MSV SEALING STEAM ELBOW X-86 TS 6 TB 9 711 T 2'l l 28 33 8 8'N18-1'EJC.179.119 X-RIOB 2SLMSV D.41 RESP95 K-562 P43673 K0562-0 I 3SCVL-E14 CV SEALING STEAM HAND GRID BEND X-9 1 TS-6 TB 12 716 T-211 27.65 8 3'S'17-4'EJC

.147.100 3SCVL D.41 K195 K0195-01 P43611 TOTAL EXAMS: 179 ECRPT2 X-RIOB RESP95 IAJREG-0313 CATEGORY C WELDS FOR MS~P APPL'NDI MSIP WELD LISTING UNIT 1)Veld Weld Ident iTica lion Size Description Out Area Room Elev CI103 a e S stent lYA Nuniber I DBB-107-1-1-8 24 RHR Div I ln'et FOISA&F017A E-P 2 DBB-107 I-A 24 RHR Div II In Bet F0158&F0178 P-E 3 D8 8-107-2-I-D 24 RkIR Div II In Bet F0158&F0178 E-P 8 29 202 710 RHR I S43957 8 28 202 711 RIIR II S43956 7 28 202 711 RHR II 4 DCA-108-I-FW-12 20 Com SDC Suet at F008 V-E 5 DCA-110-I-FW-I 24 RHR Div I In't FOISA P-V 6 DCA-110-2-FW-I 24 RHR Div II hi't F0158 P-V 7 DCB-102-I-FW-I 6 Head S ra U strm of F023 P-V 8 DCB-102-I-FW-2 6 Head S ra Dnstrin of I 023 V-Fll 9 DCB-102-I-FW-4 6 Head S ra Bet F022&F023 FII-E 10 G8 8-I 17-I-1-C 6 Head S ra Bet F023&kIVI5112 E-P 7 28 203 710 SDC Coin 8 29 202 710 RI IR I 7 28 202 710 RHR II 8 29 202 711 RIIR I 7 29 202 711 RHR I 7 26 206 711 Rl IR I 7 29 202 711 RHR I S43955 S43954 1 I HBB-111-I-I-A 20 Com SDC Suet DNSTRM of F008 E-RED 12 N I A NOZ-SE 28"A" Recirc Pum Suet NOZ-SE 13 N I 8 NOZ-SE-28"8" Recirc Pum Suet NOZ-SE 14 N2A NOZ-SE 12 Recirc Pum Riser SE-NOZ 15 N2B NOZ-SE 12 Recirc Pum Riser SE-NOZ 16 N2C NOZ-SE 12 Recirc Pum Riser SE-NOZ 17 N2D NOZ-SE 12 Recirc Pum Riser SE-NOZ 18 N2E NOZ-SE 12 Recirc Pum Riser Si:-NOZ l9 N2F NOZ-SE 12 Recirc Pum>Riser (SE-NOZ 7 28 202 711 S DC Com 7 26 516-1 746 RHR I 8.26 516-1 746 SDC Com S43947 7 26 516-1 745 RI I R II 8 26 516-1 745 RHR II S43948 8 26 516-1 745 RHR II S43949 8 26 516-1 745 RHR ll S43950 8 26 516-1 745 RHR II S43951 7 26 516-1 745 Rkl R I h

-APPENDIX MSIP WELD LISTING VNIT 1 Wekl Weld Identification Size Description Out Area a e Room Elev C 1103 S stem WA Number 20 N2G NOZ-SE 21 N2H NOZ-SE 22 N2J NOZ-SE 23 N2K NOZ-SE 24 NSA NOZ-SE 25 N5A NOZ-SEXT 26 NSB NOZ-SE 27 NSB NOZ-SEXT 28 N8A NOZ-SE 29 N8A NOZ-PEN SEAL 30 N8B NOZ-SE 31 N8B NOZ-PEN SEAL 32 N9 NOZ-CAP 12 Recirc Pum Riser SE-NOZ 12 Recirc Pum Riser SE-NOZ 12 Recirc Pum Riser Sl:-NOZ 12 Recirc Pum Riser SE-NOZ 10 CS DIV II In'ozzle SE-NOZ 10 CS DIY II In'ozzle Sext-SE 10 CSDIVI In Nozzle SE-NOZ 10 CSDIV I In Nozzle Sext-SE 4.5 Cal Jet Pum Inst Line NOZ-SE 4 Cal Jet Pum)Inst Line SE-Pen Seal 4.5 Cal Jet Pum Inst Line NOZ-SE 4 Cal Jet Pum Inst Line SE-Pen Seal 4 CRD to RPV Return (NOZ-CP 8 26 516-1 745 RHR I S43952 8 26 516-1 745 RHR I S43953 7 26 516-1 745 RHR I 7 26 516-1 745 RHR I 8 26 516-3 772 CS Non S43958 8 26 516-3 772 CS Non S43959 8 26 516-3 772 CS Non S43960 8 26 516-3 772 CS Non S43961 8 26 516-1 745 NB Non S43962 8 26 516-1 745 N B Non S43963 8 26 516-1 745 NB Non S43964 8 26 516-1 745 NB Non S43965 7 26 516-3 770 CRD Non