ML18017A282

From kanterella
Jump to navigation Jump to search
Forwards Books 1 & 2 of ISI Outage Summary Rept SSES Unit 1 8th Refuel Outage, Completed on 950714
ML18017A282
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 08/04/1995
From: Byram R
PENNSYLVANIA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17158A807 List:
References
PLA-4343, NUDOCS 9508100123
Download: ML18017A282 (249)


Text

PRIORITY MCCELERATED RIDS PROCESSING REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9508100123 DOC.DATE: 95/08/04 'OTARIZED: NO DOCKET FACIL:50-387 Susquehanna Steam Electric Station, Unit 1, Pennsylva 05000387 p AUTH. NAME AUTHOR AFFILIATION BYRAM,R.G. Pennsylvania Power & Light Co.

RECIP.NAME RECIPIENT AFFILIATION R Document Control Branch (Document Control Desk)

SUBJECT:

Forwards Books 1 & 2 of "ISI Outage Summary Rept SSES Unit 1 I

.8th Refuel Outage," completed on 95071'4.

DISTRIBUTION CODE: A047D TITLE: OR COPIES RECEIVED:LTR Submittal: Inservice/Testing/Relief JfromENCL f SIZE: l ASME Code GL-89-04 0

R NOTES 05000387 RECIPIENT COPIES RECIPIENT COPIES-ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD1-2 LA 1 1 PD1-2 PD 1 1 POSLUSNY,C 1 1 INTERNAL: ACRS 6 0 AEOD/SPD/RAB 1 1 BNTER 1 1 1 1 1 NRR/DE/EMCB'UDOCS-ABSTRACT NRR/DE/EMEB 1 1 1 1 OGC/HDS2 1 0 RES/DSIR/EIB 1 1-EXTERNAL: LITCO ANDERSON 1 1 LITCO RANSOME,C 1 1 NOAC 1 1 NRC PDR 1 1 ~ D NOTES: 1 1 N

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5DS (415-2083) TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR 21 ENCL 14

Pi

~ ~

%J

'I

~ I Pennsylvania Power 8 Light Company Two North Ninth Street~Allentown, PA 18101-1179~215/774-5151 Robert G. Byrarn Senior Vice President-Nuclear 610I774-7502 Fax: 610/774-5019

<UC 04 >995 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Station P1-137 Washington, DC 20555

\

SUSQUEHANNA STEAM ELECTRIC STATION UNIT 1 EIGHTH REFUELING AND INSPECTION OUTAGE ISI

SUMMARY

REPORT 4 Docket No 50-387 Attached for your use is a copy of the Susquehanna Steam Electric Station Inservice Inspection Outage Summary Report for the Unit 1 Eighth Refueling and Inspection Outage. A copy of this report has also been sent to the Commonwealth of Pennsylvania.

Ifyou have any questions, please contact C. T. Coddington at (610) 774-7531.

Very truly yours, Atta cc: NRC Region I (w/o)

Ms. M. Banerjee NRC Sr. Resident Inspector-SSES (w/o)

Mr. C. Poslusny, Jr. NRC Sr. Project Manager-OWFN (w/o)

II

'rr508iOOi23 950804 PDR ADOCK 05000387 Q PDR

0 A 4v

~ ~

ty N

I 1(

1" ~'

Docket' Accession 4 e ~a~~

Of Date Regulatory Docket File INSERVrCE >NSPEer>ON Ltt'UTAGE S ARY REPORT Pennsylvania Power & Light Company Two North Ninth Street Allentown, PA 18101-1179 COVER PAGE Susquehanna Steam Electric Station P.O. Box 467 Berwick, PA 18603 UNIT 1-8TH REIi VEL OUTAGE COMPLETION DATE - July 14, 1995 COMMERCIALSERVICE DATE - June 8, 1983 COPY BOOK20F2

4 f~giagoQ

'!lJ t~, " ~idf38'3JQA eisG

!i-I .exooG go(slurpR

rVrODIVIC~nONrWSr~r,I.LIOW Ga.OUP NIS-2 FORMS

WORK ABSTRACT The Modification Installation Group is responsible for preparing Construction Work Authorizations ( work packages) for fabrication and installation of design changes in accordance with ASME Section XI and the National Board Inspection Code. This work is documented on NIS-2 Forms, or on R-1 Forms, which are submitted herewith.

MODIFICATION INSTALLATIONGROUP Design Change Packages for ASME Section Xl (Class 1, 2 and 3 ), and the National Board Inspection Code, installed in Unit 1 since the completion of the Seventh Refueling Outage through completion of the Eighth Refueling Outage are summarized below:

DESIGN CHANGF SYSTEM / CLASS PACKAGE DESCRIPTION NUMBER 90-9095 125A III Modify various pipe supports 94-3018 139 Install sight glasses in G condensate demineralizer 94-3021 A 139

  • Install sight glasses in A condensate demineralizer 94-3021D 139 Install sight glasses in D condensate demineralizer 94-3021 E 139
  • Install sight glasses in E condensate demineralizer 94-3021 F 139 " Install sight glasses in F condensate demineralizer 93-3090A, B, C 8 D 149A II Replace bonnets on valves 151 F031A, B, C 8 D 93-3092A 8 B 151A II Replace bonnets on valves 152F003A, B, C 8 D 93-3077 152B II Replace disc in valve HV-1 55F001 89-9153 B 154A III Modify various pipe supports 94-3023A & D 154A III Installed new piping to RHR Pump Motor Oil Coolers 93-3069 155B II Modify various pipe supports 93-3059A, B & C 162A I Installed reactor water level condensing chambers 94-9088 164A I Modified pipe support SP-DCA-1 51-H2008 95-9025 173A II Removed valve actuator supports 89-3018D 173A II Installation of new CRM piping 93-3086 184
  • Added nozzles in 1T105A 93-3086 184" Added nozzles in 1T105B Repair of an ASME section Vill vessel in a non-nuclear system.

125A lll FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date May 5, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of
2. Plant Susquehanna Steam Electric Station Unit One Name DCP 90-9095, WA C33306, C33307 PO Box 467, Befwick, PA 18603 Address Repair Orgartlzatrerr P.O. Na, Job Na, etd,
3. Work Performed by Penns Ivania Power 8 Light Co. Type Code Symbol Stamp None Name

'Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A

4. Indentlllcation of System CONTAINMENTINSTRUMENT GAS SYSTEM 125A CLASS III
5. (a) Applicable Construction Code III 19 71 Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 thru Vtf80 and IWF-7000, Winter 1982 Addenda
6. Identication of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

PIPE SUPPORT BECHTEL N/A N/A SPCCC-102-H1 19S2 REPAIRED NO PIPE SUPPORT BECHTEL NIA SPNCC-139- REPLACED NO H2016 PIPE SUPPORT BECHTEL NIA NIA SP-KCC-139- 1982 REPLACED NO H2003 PIPE SUPPORT PP+L NIA SP-HCC-139- 1994 REPLACEMENT NO H2003 PIPE SUPPORT BECHTEL NIA N/A SP-CCC-101- 19S2 REPLACED H2004

7. Description of Work Pipe supports were modified and repaired to su ort ipin rework
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure NONE REQUIRED Other Pressure psl Test Temp. ep NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is SN in. x 11 in., (2) Informa tion ln items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(12I82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

FORM NIS-2 (Back) 9 Remarks This NIS-2 is being submitted to report pipe support work that should have been included in an Appticabte Manulacturer's Data Reports to be attached NIS-2 fors stem125A-III reviousl submittedwith the Unit1 Seventh Outa e Summa Re ort.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Cernlicate of Authorization No. N/A Expiration Date N/A Signed Date ,19 Own r or ers Oesltinee, Trtte VP&uc Operations P5 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel inspectors and the State orProvinceof P S ANIA andemployedby A RIG TMUTUA INSU CECO. of THAM MASSAC USETTS have inspected thegrgenents described in this Owners Report during the period to 0- p-to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this and state that Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ovmer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inJury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions AB S6k ~ X4b Inspector's Signature Board, State, Province, and Endorsements

/5'ational Date

FORM R-1, REPORT OF WELDED QX REPAIR OR as required by the provisions of the National Board Inspection Code Q ALTERATION 139

1. Work performed by Penns Ivania Power and Li ht DCP 9430(8 / WAt) C43803 (name or re petr or alteradon or()anizatton) (p.o. nolob no., etc.)

Two North Ninth Street, Allentown. Pa. 18101 (address)

2. Owner Penns Ivania Power and Li ht (name)

Two North Ninth Street, Allentown. Pa. 18101 (address)

3. Location of installation Su uehanna Steam Electric Station (name)

P.O. Box 467, Be(wick, Pa. 18603 (address) unit Ident(((cat(on: Condensate Oemlneralizer Name of original manufacturer Allied Steel Products Co oration (bolter, pressure vessel)

5. Identlfylng nos: W-8496-C 7734 PA469348 1F-106 G 1975 (mrr's serial no.) (ortt)lnal Nadonal Board no.) ()unsdtctton no.) (otnet) (rear bulk)
5. Description of work: installed two J.G. Papailias Co. Inc., Slghtglasses Parttt NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate sheet, or sketch tr necessar)t)

Pressure test, lfapplied 520 psl Ref)hcerntmt Parts. Attached ae Manufacturers'Patthl Data Reports property lntfenti5ed and signed by Authorlnxf hspectors for the tolowing items of this repott NONE (name or pan, Item number, mll's. name and ldendrrtns stamp)

8. Remarks:

NONE Th)s form may be obtained from the Nathnal Board of Boiler and Pressure Vessd Inspectors, 1055 Crupper AveColumbus, OH 43229

DESIGN CERTIFICATION The undersigned certifies that the statements made in this report are correct and that the design changes described ln this report conform to the requirements of the National Board Inspection Code.

ASME Certificate of Authorization no. to use the symbol expires 19, Date 19 Signed (name of organlzadon) (alrthonzed fepresentadve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Commlsion issued by the National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of and employed by of has examined the design change as described in this report and ver(Iles that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board inspection Code.

By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or knplled, concerning the work described in this report. Futthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such I(ability as may be provided In a policy of in surance which the undersigned's insurance company may Issue upon said object and then only in accordance with the terms of said policy.

Date 19 gtgnee Commissions (Authortzed Inspector) (National Board (IncL endorsements), state, prov., and no.)

CONSTRUCTION CERTIFICATION

'o The undersigned ce)tifles that the statements made in this report are correct and that all construction and workmanship on this R I conform to the National Board Inspection Code.

(repair or alteration)

Certificate of Authorization no. A use the NI symbol expires 19 Date~~3/ 19~$ Penna tVentePDWerendLi ht Sl ned (name or repair organ(zadon) (a ortzed representadve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Commision issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of NS Nl and employed by G M A NSU NC CO of SS has inspected the work described In this report on Ot 19~~

and state that to the best of my knowledge and belief this work has been done In accordance with the National Board Inspection Code.

By signing this certlflcatee neither the undersigned nor my employer makes any warrenty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable ln any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided ln a policy of in surance which the undersigned's Insurance corn y Issue upon said object and then only In accordance with the terms of said policy.

Date 19~~ Signed Commlsslons 4 (Authorized Inspector) 8oard (IncL endorsements). state, provand no.)

5'Nadonal

FORM R-1, REPORT OF WELDED [7X REPAIR OR ALTERATION 139 as required by the provisions of the National Board Inspection Code 1~ Work performed by Penns Ivania Power and Li ht DCP 944021A / WA¹C43506 (name of repair or arteratlon organlzatton) (p.O. no.,)ob no., eto.)

Two North Ninth Street, Allentown, Pa. 18101 (address)

2. Owner Penns lvania Power and Li ht (name)

Two North Ninth Street, Allentown, Pa. 18101 (address)

3. Location of installation Sus uehanna Steam Electric Station (name)

P.O. Box 467, Be(wick, Pa. 18603 (address)

4. Unit Identification: Condensate Dentineralizer Name of original manufacturer Allied Steel Products Co oration (boiler, pressure vesset) 6, Identifying nos: K74-70 7590 PA469342 1F-106A 1975 (mfrs serial no.) (ortglnal )(adonai soard no.) 0uttsdlotlon no.) (other) ~ (year boih)
6. Description of work: Installed two J.G. Papaillas Co. Inc., Slghtglasses Part¹'NW125DW/HP/316/CS/CS/TBS/NAS (use baott separate sheeb or sttetoh If neoessaly)

~

Pressure test, If applied 550:. psl

7. Replacement Parts. Atbtched are Manufacttsers'Parti)i Data Reports propedy hdenNed and s)gnedbyAuthodzed hspectors for the folowi)g items of this report NONE (name or part, Item number, mfrs. name and Idenutytnt) stamp)
8. Remarks:

NONE This form may be obtained from the Nathnal Board of Boiler and Pressure Vessel Inspectors, 1066 Crupper Aveco(umbus, OH 4322S

DESIGN CERTIFICATION The undersigned 'certifies that the statements made in this report are correct and that the design changes described In this report conform to the requirements of the National Board Inspection Code.

AS ME Certificate of Authorization no. to use the symbol expires 19, gate 19 Signed (name or organlzauon) (atnnortzed representaave)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Comm)sion issued by the National Board of Boiler and Pressure Vessel inspectors and certificate of com-petency Issued by the state or province of and employed by of has examined the design change as described in this report and verifies that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board Inspection Code.

By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or implied, concerning the work described ln this report. Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided ln a policy of In surance which the undersigned's insurance company may Issue upon said object and then only in accordance with the terms of said policy.

Sale 19 Slgeed Commissions (Autnorlzed Ins pector) (Nauonal Board (Ind. endors<<nants), stats. prov., and no.)

CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made in this report are correct and that all construction and workmanship on this R I conform to the National Board Inspection Code.

(repair or altered on)

Certificate of Authorization no. to use the symbol expires 19 Oate~d& I 19 95 Penns Ivania Power and Li ht Sign (name or repair organlzatlon) (a orlzed representadve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Comm(sion issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of P S Nl and employed by A A SU NC CO.

of A S has inspected the work described In this report on 192 and state that to the best of my knowiedge and belief this work has been done In accordance with the National Board Inspection Code.

By signing this celtificatee neither the undersigned nor my employer makes any warrenty, expressed or Implied, concerning the work described'in this report. Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal Injury, property damage or toss of any kind arising from or connected with this inspection, except such liability as may be provided in a policy of in surance which the undersigned's Insurance compa issue upon said object and then only in accordance with the terms of said policy.

Date 19~~ Signed Commissions (Atnnortzed Inspector) (Madonal Board (Incl. endorsements). state. prov., and no.)

FORM R-1, REPORT OF WELDED QX REPAIR OR as required by theprovisions of the National Board Inspection Code Q ALTERATION 139

'I

1. Work performed by Penns Ivania Powerand Li ht OCP 9430210 / WA¹ C43452 (name of repair oractecauon ort)an(tauon) (p.o. nojob no.. etc.)

Two North Ninth Street, Allentown, Pa. 18101 (address)

2. Owner Penns Ivania Power and Li ht (name)

Two North Ninth Street, Allentown, Pa. 18101 (address)

3. Location of installation Sus uehanna Steam Electric Station (name)

P.O. Box 467, Be(wick, Pa. 18603 (address)

4. unit Identification: Condensate Defnineralizer Name of original manufacturer Allied Steel Products Co oration (boiler, pressure vessel)
6. (dentlfylng nos: K74-70 7583 PA469345 1F-1 06D 1975 (mfrs serial no.) (octgtnat Kauonat eoacd no.) ()uctsdlctton no.) (other) (year built)

(). Descr(ption of work; Installed two J.G. Papaillas Co. Inc., Slghtglasses Part4 NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate sneeb or sketch Ifnecessaly)

Pressure test, if applied 500 psl

7. Replacement Parts. Attached ae Mawfactufefs'PaftktlOata Reports propedy ktttenti5ed and signed by Att(hoftzedktspectofsforthe items of this report NONE (name of pact, Item number, cnh's. name and tdenttfytnt) stamp)
8. Remarks:

NONE This form may be obtained from the 44athnal Board of Bo()er and Pressure Vessel inspectors, 10(M Crupper Avecolumbus, OH 43229

QESIGN CERTIFICATION The undersigned celt(iles that the statements made in this report are correct and that the design changes described In this report conform to the requirements of the National Board inspection Code.

ASME Certificate of Authorization no. to use the symbol expires 19 Sate 19 Signed (name of organizadon) (authorized rsprsentatlvs)

CERTIFICATE OF REV(EW OF OES(GN CHANGE The undersigned, holding a valid Commision issued by the National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency Issued by the state or province of and employed by of has examined the design change as described In this report and verNes that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board inspection Code.

By signing this certificate, neither the undersigned nor his employer makes any waaenty, expressed or Implied, concerning the work described (n this report. Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal injury, property damage or loss of any kind arising from or connected w(th this inspection, except such liability as may be provided in a po8cy of in surance which the undersigned's insurance company may Issue upon said object and then only In accordance with the terms of said policy.

Sate 19 Staaed Conan(ss(ons .!

(Alnhottzed Itlapsctor) (National eoard (IncL endoraementa), state, prov., an4 no.)

CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made In this report are correct and that all construction and workmanship on this A( conform to the National Board Inspection Code.

(repair or altsladon)

Certificate of Authorization no. Nl to use the symbol expires 19 Sate ~~>l 19~~ Penns Ivania Power and Li ht (name of repair organtzadon)

Sign uthorlzed reprentatlve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Convnls(on issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency Issued by the state or province of NS and employed by G V NC CO of THA ASS has inspected the work described in this report on 19~a and state that to the best of my knowledge and belief this work has been done in accordance with the National Board inspection Code.

By signing this certilicate, neither the undersigned nor my employer makes any warrenty, expressed or Implied, concerning the work described in this report. Furthermore, ne(ther the undersigned nor my employer shall be liable ln any manner for any personal injury, property damage or loss of any kind arising from or connected with this Inspect(on, except such liability as may be provided in a policy of in surance which the undersigned's insurance company may issue upon said object and then only In accordance with the terms of said policy.

Oat ~~ 19~~S(gned (Authorized Inspector)

Comfnlsslons (Madonal 8oanl (In4. endorsementa). stats, prov., and no.)

FORM R-1, REPORT OF WELDED QX REPAIR OR Q ALTERATION 139 as required by the provisions of the National Board inspection Code

1. Work performed by Penns Ivania Power and Li ht OCP 94402(E / WA¹ C43434 (name of repair or atteratt on organlzatt on) (p.o. no..)ob no., etc.)

Two North Ninth Street, Allentown. Pa. 18101 (address)

2. Owner Penns lvania Power and Li ht (name)

Two North Ninth Street, Allentown. Pa. 18101 (address)

3. Location of installation Sus uehanna Steam Electric Station (name)

P.O. Box 467, Be(vfick, Pa. 18603 (address)

4. Unit(den(I(teat(on: Condense(eDefninefa~<er Nameoforlglnalmanufacturer Allied Steel Products Co oration (holler, pressure vessel)
5. Identifying nos: W-8496-B 7717 PA469346 1F-106E 1975 (mh's serial no.) (ortglnal Nattonat eoard no.) ()urtsdlcdon no.) (other) (rear bout)
5. Description of work: Installed two J.G. Papailias Co. Inc., Sightglasses Part¹ NW125DW/HP/316/CS/CS/TBS/NAS (use back, separate sheer. or sketch lr necessary)

Pressure test, ifa pplled 500 psi Rep(acenslt Parts. A(tached ae Mfstuhchsers'Pafth(Data Repotts property i)tketi5ed and sk)nedby Mhortzedk)specters for the folowitg Rems of(tis report NONE (name of part, Item number, mfrs. name and Identhytng stamp)

8. Remarks:

NONE This fonnmay be obtained from the National Board of Bo(ler and Pressure Vessel inspectors, 1055 Crupper AveColumbus, OH 43229

DESIGN CERTIFICATtON The undersigned certifies that the statements made In this report are correct and that the design changes described ln this report conform to the requirements of the National Board inspection Code.

ASME Certificate of Authorization no. ta Use the symbol expires 19 gate 19 Signed (name of organlzadon) (aumorlzed representauve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Cortxntston Issued by the National Board of Boiler and Pressure Vessel inspectors and certificate of com-petency Issued by the state or province of and employed by of has examined the design change as described in this report and verities that to the best of his knowledge and belief such change compiles with the applicable requirements af the National Board Inspection Code.

By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or Implied, concerning the work described ln this report. Furthermore, neither the undersigned nor my employer shall be liable ln any manner for any personat injury, property damage or loss of any kind arising from or connected with this Inspection, except such liability as may be provided In a policy of ln surance which the undersigned's insurance company may Issue upon said object and then only In accordance with the terms of said policy.

gate 19 gtgeed Commlsstans (Autnortzed Inspector) (Nadonal Board (IncL endorsements), state. prov., and no.)

CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made in this report are correct and that all construction and workmanship on this R conform to the National Board inspection Code.

(repair or alteradon)

Certificate of Authorization no. M/A to use the symbol expires Oate~~B/ 1995 Penns Ivania Power and Li t SI (name of repair organlzadon) (authorized representative)

CERTtFICATE OF INSPECTION The undersigned, holding a vagd Commislan issued by The National Board of Boiler and Pressure Vessei Inspectors and certificate of com-petency Issued by the state or province of S I and employed by G SU NCE CO of A A ASS hasinspectedtheworkdescrtbcdinthis report on 19~

and state that to the best of my knowledge and belief this work has been done in accordance with the National Board inspection Code.

By signing this certificate, neither the undersigned nor my employer makes any warrcnty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided In a policy of in surance which the undersigned's insurance compa y Issue upon said abject and then anly In accordance with the terms of said pa(Icy.

Date 19~ Signed (A orlzed Inspector)

Commissions (katlonal Board (Incl. endorsements), state, prov., and no.)

FORM R-1, REPORT OF WELDED X REPAIR OR as required by the provisions of the National Board Inspection Code Q ALTERATION 139 Work performed by Penns Ivania Power and Li ht DCP 944021F / WA() C43419 (name of repair or alteradon ort)antsadon) (P.O. no)ob noetc.)

Two North Ninth Street, Allentown. Pa. 18101 (address)

2. Ovmer Penns lvania Power and Li ht (nemo)

Two North Ninth Street, Allentown, Pa. 18101 (address)

3. Location of installation Sus uehanna Steam Electric Station (nemo)

P.O. Box 467, Be(wick, Pa. 18603 (address)

4. Unit identification: Condensate Demlnefartzer Name of original manufacturer Allied Steel Products Co oration (boiler, pressure vessel)
6. Identifying nos: W-8496-A 7729 PA469347 1F-106F 1975 (mfrs sertat no.) (ont)Inst ffadonat eoard no.) Ourlsdlctlon no.) (other) (year bulk) 6, Descf(ptlon of)Nork; Installed two J.G. Papailias Co. Inc. Sightglasses Part¹ NW125DW/HP/316/CS/CS/TBS/NAS

~

(use back, separate shor, or sketch If necossal)f)

Pressure test, ifapplied 550:. ps(

Rep/aceamtt Parts. Attached ae Mawfacttatss'Paftktl Data Repotts property ktdeftd(led and signedby Au(hoftzedktspectofs for the items of th(s report NONE (name of part, Item number, mh's. name and tdenetylnt) stamp) 8, Remarks:-

NONE This form may be obtained from the Nathnal Board of Boiler and Pressure Vesse) Inspectors, 1056 Crupper Avecolumbus, OH 43229

DESIGN CERTIFICATION The undersigned celtifles that the statements made In this report are correct and that the design changes described in this report conform to the requirements of the National Board inspect)on Code.

ASME Certificate of Authorizat)on no. to use the symbol expires 19 Date 1S Signed (narll ~ of organlzadon) (atnhorlzed representadve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Const)Is(on issued by the National Board of Boiler and Pressure Vessel Inspectors and cerdflcate of com-petency issued by the state or province of and employed by of has examined the design change as described in this report and verifies that to the best of his knowledge and belief such change compiles with the applicable requirements of the National Board Inspection Coda By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or knplied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable ln any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such Ilabllity as may be provided in a poHcy of ln surance which the undersigned's insurance company may Issue upon said object and then only in accordance with the terms of said policy.

Date 1S Stgeee Comnissions (Authortzed Inspector) (National eoard (Inct. en4orsements), state. prov., an4 no.)

CONSTRUCTION CERTIFICATION The undersigned certifies that the statements made In this report are correct and that all construction and workmanship on this I conform to the National Board Inspection Code.

(repair or alta radon)

Certificate of Authorization no. to use the symbol expires Date ~>>~ ta g~ Penns Ivania Power and Li ht SI (name of repair organlzadon) authorized representative)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Commlsion Issued by The National Board of Boiler and Pressure Vesse nspectors and certificate of com-petency Issued by the state or province of Nl and employed by SU CE CO of ASS has inspected the work described in this report on and state that to the best of my knowledge and begef this work has been done In accordance with the National Board Inspection Code.

19~

By signing this certificate, neither the undersigned nor my employer makes any warrenty, expressed or knpged, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable In any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such Iiab)gty as may be provided ln a policy of In surance which the undersigned's Insurance compa y Issue upon said object and then only In accordance with the terms of said policy.

Date 19 Signed Commissions (Authohzed Inspector) (Nadonal scald (Inc. endorsements). state, prov>> and no.)

149AI)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date May 8, 1995 Nafrre Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One Nalrie DCP 934090A,B,C,&D Work Authorizations C43725, PO Box 467, Berwick, PA 18603 C43726 C43727 C43728 Address Repair Oiparriaaboo P.O. No., Job No., eto.
3. Work Performed by Penns Ivania Power & Light Co. Type Code Symbol Stamp None Narrre Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentificatlon of System Residual Heat Removal S stem 149A Class II
5. (a) Applicable Construction Code III 19 71 Edition, thiu W72 Addenda, Code Case (b) Applicable Edmon of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code Replaced, or Stamped Name of Name of Manufacturer Other Identiilcation Year (Yes or Component Manufacturer Serial No. Built Replacement No)

BONNET MCC PACIFIC S/N XN050 151F031A 1976 REPLACED YES VALVES BONNET CONTROL M61 8920-S/N3 NIA 151F031A 1994 REPLACEMENT YES COMPONENTS INC.

BONNET MCC PACIFIC S/N XN051 NIA 151F031B 1976 REPLACED YES VALVES BONNET CONTROL M61 8920-S/N2 N/A 151F031B 1994 REPLACEMENT YES COMPONENTS INC.

BONNET MCC PACIFIC S/N XN052 151F031C 1976 REPLACED YES VALVES BONNET CONTROL M61 892~/N1 N/A 151F031C 1994 REPLACEMENT YES COMPONENTS INC.

7. Description of Work Replace Bonnets on RHR Discharge Check Valves
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure SE-1 &301 Other Pressure See Remarks psl Test Temp. See Remarks F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, prodded (1) size ls SN in. x 11 in., (2) lnforma tlon In items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets I recorded at the top of this form.

(12/S2) This form (E00030) may be obtained from the Order Dept. ASME, 345 E. 47th St., New York, N.Y. 10017

~

FORM NIS-2 (Back) g Remarks CODE DATA REPORT(S) ATTACHED Ap pticat9le hlanufacturar's Oats Repons to ba attached 151F031A - Pressure: 310 .s.i. /Tem erature: 68'F, 151F031B - Pressure: 265 .s.i. /Tem erature:

69.3'F 151F031C - Pressure: 235 .s.i. / Tem erature: 71.5'F, 151F031D - Pressure: 270 .s.i. /

Tem erature: 66.3'F CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certilicate of Authonzatlon No. N/A Expiration Date N/A Signed ers Oeslgnae. Titte~VP&uc Operations Date 3/,tg gS CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof P NNSY VANIA and employed by ARKWR G A SU NC CO of WA KAM MASSAC US S have sp edthycomponentsdescribed in this Owner's Report during the period to Z 9 5 and state that to the best of my knowledge and belief, the Owner has p orm examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in a ner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions dc bl9 Inspector's Signature National Board, State, Province, and Endorsements Date 19~5

Form N-2 FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR iDENTICAL NUCLEAR PARTS AND APPURTENANCES's Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Ptuduction Pg. 1of2

1. Manufactured and certttodby ~~onents etc. 22591 Aceerkfs Ernprosa, Fhncho Srr/ttrr Mrr/gdr/trr. C4 928M tcame and oddreae cr C<<Cnoaio Head<<t
a. Monutecturect tor PENNSYLVAN/4POWERS L/GHTOO. ALLEPflOWN, PA toama and <<Odreae ct puacnae<<)

SVRX/EHANNASTEAM ELEIOTRC STAT)ON. 5M/LES NE OF BERWJCK PA.ON RO(JTE 11 tccrne cnd eddreaa)

4. Typo 748800001 SA-105 70.000 PS/ N/A (dr<<who ncc) tnacl apeo. na) Oanete caranoo)
5. ASM'ode, Sec5on NI, DMaton 1 1971 WlVTER 1972 2 (otaaa) (Cede Case na)
0. Fabrtcaied h accordance catch Const. Spec. (DN. S onty) N/A Rovhbn PVA oas N/A hcc)
y. Remertcs PARTPORA 20 PV GHEO/r; VALVE.

CO/ WOR/r:ORDER r//852001/2-001 OO/DWG. R O. M P/N 748802001.

tt. Nom lhkkneee (ta) 8.47 Mh. design thkkness (tn.) S.dd'ta. 6 (tt S h.) 29 length ovenul (tt S h,) NIA Q. When applkable, Certtwcato Holders'ata Reports are attachod for each ttem ot thts ropoC Na5onof part or Apurtonanco Board No. Sec(s) Ncxnber Board No.

h Numerkat Order adh (1.) M8 18920 Sr%/ 1 (gg.)

(2.) M8f8920 Qfc/2 &)

p.) M81 8920 Sr8 (gL)

(4.) M818920 Sr'/ d (gg)

(5) PO.)

(0.) Pt)

P) (ag )

(5) PO.)

(0) p4.)

(10.) P5)

(11.) PO.)

(t<) P~)

(1 0.) PO.)

(14) Ptt)

(1 5.) (40.)

(1 0.) (41.)

(1 7.) (4g )

(10.) (40)

(10) (44)

(go.) (45.)

(gt ) (40)

Pg) (4~)

(gx) (4tt)

(g4 ) (40.)

(g5.) (50.)

10. Deatgn preaacxo pat. Temp. 100 Deg.F scoorcm<<eat hramadm h ace tamer sara, arceknea, or dr<<whoa mer be uaed pcadded (1) ake la 4 Qsx 11.

la horodad cn each aneac, (ot coen aneac la accbered and he ncaobar b ahaoce 1 receded 4 ho lop cr octa tam Q ~

ttydrateatpreeecxo 1Na tam gCCOac) may be cblahad trcm he Order Dept, Asle, 22 Lew Drlre, Sac @NO, FaÃatd. Nf Otter-ZXrL N/A attemp.Deg.F h s<<sea tends cn octa Dree napat

Fona N-2 FORM N-2 (Back Pg. 2 of ~2 Csrttrioata Holder's Serial Noa SEE PAGE 1 through AtIA R4l4V V. PAREKH PX. State PA ltag.nba 29882-E Design repat e oertned by N/A Iteg. nrL N/A wsoatyy cue tra tat<<nen4 made h hte report ae ocnsol and sue tee ttheeel VALVEBONNET'CAP ocnkams io tra nAos d ocnettuctkn d tw hSLE DxK Seotkn 5, Dtrtekn t.

%ry eartytoets d Auhattatkn Hra Bptrse JUNE7.

19'1/&

I ~J g Nano COVTTIOLCOMPONENTS INC Stetted 1 L tea tatderatgn<<L hddhg ~ valid ocnvntsskn Issued by he Natknal Bead d Boter and Pr>>>>euro Vessel hap>>ster>> and tts Stae a Provhoe d CALIFORNIA and anploy>>d by HARTFORO STEAAl BOILER INSPEC77ON AIVOINSURANCE COMPANY ol HARTFORO. CONNECTTCLIT'ave twpeoted ttese tamaaectttadhhte Dec>>Report cn - 1L . and atua Stat to yt beet d my on<<tedge end better. ere eettkate Hdder haa tabrtxtad hase pena a appurtataees h aaxadanos wgt ets hsL6 ctx4 8ecckn 5, D4iskn t. Each pat I>>ted has bean <<rAarlced ta atarsrhg cn he dais shown abov>>

By signhg eAe oertrkate. nether eta hapector not hk employe< makes warranty. a>>press>>ed or ~trod, ocnoemhg ete actutxnent de>>orbed h ttts Data ltepaL PLrrct<<ma>>, neiher ate hepecccr nor his smptoyet chas be srb4 h arry master raary per>>anat hhayaprop<<ty damage a toss deny khd aiahg trcm

~.Q.fc cLr-n a

.~oovtectsd etta eepeotkn grecl Bd. (hokrdhg endor>><<neng and aura a prcN.. rnd nct) ae REFER TO ATTACHED 'LETTER OFEXTHVSION'ROMTHEASMECARMIT7EE

149AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 8, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name DCP 934090A,B,C,&D Work Authorizations C43725, PO Box 467, Betwick, PA 18603 C43726 C43727 C43728 Address Reparr Orriaaraabon p.O. No., Job rro. ~ etc.
3. Work Performed by PennSylVania POWer & Light CO. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentificatlon of System Residual Heat Removal S stem 149A Class II
5. (a) Applicable Construction Code III 19 7" Edition, thruW72 Addenda, Code Case (b) Applicable Edition of Section XI UtiTized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

BONNET MCC PACIFIC S/N XN049 N/A 151F031D 1976 REPLACED YES VALVES BONNET CONTROL M61 892~/N4 N/A 151F031D 1994 REPLACEMENT YES COMPONENTS INC.

QNa eat shzdsW S M Amerfeen lageos g Me0hIAIClt Elghylg 4Xl%01l1ilh lhlf Clf55cCloh QS QstL7e greg

. 5248-3341 ~tw 704. NY >Nil Fsr 2l240&4713 0'une 2. 1994 4

Nr. Robert S. Togping1 NQI. Qh CCNTROT COMPONENTS ZNC.

22591 Lvenida Eapresa Rancho Santa Margarita CA $ 2688 Sub)acti . Ixtenaion of Expiration Date fox AINE Certificatei of Authorization for 5 a NPT'N-1695 a N-2696) s Exp.

6/7/91 a az wr. VoyyXagi This letter ia to serve aa en extension of expiration date for the subject Certificate for sthich the current expiration date ia June 7, 1994.

Since the xesultI of the ASME survey conducted on April ll-13>

L9I94 are presently heing evaluated hy the AS)K, this extension vill allow <<ufficient tine for the evaIuation to be cceylotad.

Aexofore, this extension vill expire upon the Cate of the ccenplotion of the evaluation of the results or on September SO<

1994 vhichevez cosei firlt.

Very truly yours, WWI ~ I~

Joseph A. Ruseo Manager, hccroditation (212) 605 3387 cc: 1ZA-Hartford steam IoLler/heslie Bkora State of Ck/John Leaire Chnn., SC-Nh FSle/CNPT 4

c'ta~rn mi~ anuritaw < iT ~ AT < OO ta tabac

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 10, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Addieaa
2. Plant Susquehanna Steam Electric Station Unit One Name DCP 934092A& B Work Authorizations C43721, PO Box 467, Berwick, PA 18603 C43752 C43722 C43753 Addreaa Repair Organizaboir P.O. No., Job No., eto.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Addreaa Expiration Date N/A
4. Indentificatlon of System Core S ra S stem 151A Class II
5. (a) Applicable Construction Code III 19 71 Edition, thru MP72 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

BONNET MCC PACIFIC S/N XN131 NIA 152F003A 1976 REPLACED YES VALVES BONNET CONTROL M618930-S/N2 N/A 152F003A 1994 REPlACEMENT YES COMPONENTS INC.

BONNET MCC PACIFIC S/N XN130 N/A 152F003C 1976 REPlACED YES VALVES BONNET CONTROL M61 8930-S/N1 NIA 152F003C 1994, REPLACEMENT YES COMPONENTS INC.

BONNET MCC PACIFIC S/N XN129 NIA 152F003B 1976 REPLACED YES VALVES BONNET CONTROL M61 89354/N3 N/A 152F003B 1994 REPLACEMENT YES COMPONENTS INC.

7. Description of Work Replace Bonnets on Core Spray Discharge Check Valves
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure SE-151 301 Other Pressure See Remarks psi Test Temp. See Remarks F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8N in. x 11 in., (2) informa tlon ln items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets I recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

FORM NIS-2 (Back)

9. Remarks CODE DATA REPORT(S) ATTACHED Applicable Manufacbrrera Data Repcrta tc be artachert 152F003A&C - Pressure: 290 .s.i. / Tem erature: 96.8 F 152F003B&D - Pressure: 299 .s.i. /

Tem erature: 67.6'F CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repairer replaCement Type Code Symbol Stamp N/A Certificate of AuthorizaUon No. N/A ExpiraUon Date N/A Signed Date ,19 er r er'a Deaipnee, Titl Vp+uc Operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, ho! ding a valid commission issued by the NaUonal Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof SY V NIA and employed by AR GHT MUTUA SURANC CO of WA A MASSAC US S have.fnspect the components described in this Owner's Report during the period to ZC> W and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examfnations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor hfs employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Sfgnature Commissions ~el National Board, State, Provfnce, and Endorsements Date 19~&

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 10, 1995 Name P';

Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address Plant Susquehanna Steam Electric Station Unit One DCP 93-3092A& B Work Authorizations C43721, PO Box 467, Berwick, PA 18603 C43752 C43722 C43753 Address Repair Orgaoizabon P.O. No., Job No. eto.

~

3. work Performed by Penns Ivania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA=18101 Authorization No. N/A Address Expiration Date N/A
4. Indentillcatlon of System Core S ra S stem 151A Class II
5. (a) Applicable Construction Code III 19 71 EdiUon, thru W72 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code Name of No. Replaced, or Stamped Name of Manufacturer Other Identification Year Component Manufacturer Serial No. Replacement (Yes or Built

. No)

BONNET MCC PACIFIC S/N XN132 N/A 152F003D 1976 REPLACED YES VALVES BONNET CONTROL M618930-S/N4 N/A 152F003D 1994 REPLACEMENT YES COMPONENTS INC.

S The Amirfcin5pgsty oT tefaa aaf Cszfggg MOChlhlCIt Blglniirg mAhf'on ind CIrNcetan 345 East47e Rntl

~

~ 52454S1 New Yorker. NY 'l00ll Fst 21240647'l3 Nunc i, l994 Nr. Robert S. Tnppine> Igr. QA COHTROZ COMPONENTS XNC e 22591 @venido Eapresa Rancho Santa Margarita, CA 02688 Sub)eat: Extension of Expiration Date for hSME CertifLcates of l

Authorization fox 5 NPT (5-2695 a N-2696) s Exp.

6/7/04 Doer Mz.'oypinyi This letter Ls to serve as an extension of expiration date for the subject, Certificate for which the current"exyiracion date is June 7, 1994.

Since the results ef the LBME survey conducted-on April 11-)3<

)994 ero presently hei'valuated hy the aSNE, this extension vi)1 allov sufficient togae for the evaluation to be cceylated.

Therefore, this extension will expire upon the date of tho cceplotkon oX the evaluation of the results or on Beytembor 80f

.l994 whichever cories first.

Very truly yours,

~ so

~ ggygggggggVWO~O

~ ~

~ h~ '4 ~

~ ~

~ ~ IO C

Joseph L. suseo Manager, Accreditation (2)2) 605 3387 JAR/mn cc: Ale-Hartford Steam Bojler/heIXie Slcora State of Ch/John Leaire Ckhtl ( SC-N F5.le/CAPT 5'V O'OB6C COB LTL ~SlbHNOdK03 10%803 'T:OT -'6-6 -9 -AG LlGS

Form N-2 FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES>>

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of2

1. Manlrscrtxed and cercrwd by ccnfroI ccrrrpcsispnrs Iitc. 22591 Awn'cfd Emprcssa, RdrtcIsosrrnfrr Margrrrrfd, cA 92688 twme and eddceee ct Cecrnssle Hctded
2. Mancdacaxed for PENNSYLVANIAPOWERS LIGHTCO.. ALLEWUWN.PA hams snd address cf sctwsed
3. Locadon of lnstaffsdon S(JSO(JEHANNA S7EAM ELECTRCSTAT)ON 5MILESNE OFBERWICK PRON RO(JTE 11 hema and address)
4. Type 748800001 SA-105 70000PSI N/A (drescho net) tmstl apex ncs) (ssnele atrsntrO) fctt10 L ASM'ode, Secdon N, Dtstefon 1 1971 WINTERf972 2 (edttcn) r (addenda dste) rstase) (Cede Csee ncs)
0. Fabrfcated tn accordance with Const Spec. (Olv. 2 only) hYA llevwon IIVA oa>> N/A tscs)
r. R nwrtcs PARTFORA r2 PV CHECKVALVE CCI WORKORDER rF652001/2-008 CCI DWG. 8, O. hI. P/N 74880100I.

tL Norrt thtctcness (lit) 247 Mfa desfgn thfctclwss oit) 2.44'fs. 0 (ft tL lL) 229 Len0th overall (tt tL fiL) NIA

0. When applicable, Cerdtftcate Holders'ata Reports are attactwd for each Item of thfs repoC Natfonsf part or Apcrrtenance Natfonaf Bcwd No. Serial Ncxnber Bcwcf No.

In Numertcsd Order ln Ncxlleftcsf Order It(6f8980>> 9/N I NA (2cL)

(2.) M6f89SO Sr%2 NA (2y.)

(3.) M618980 St(VS N/A (2L)

(4.) N618980- SW4 N/A (21L)

(5) (30.)

(fL) Pl.)

P) P2)

(0) P3.)

(0) P4)

(10) p5.)

(1 1.) PtL)

(12.) py)

(13.) (3L)

(14) P0)

(1 5.) (40.)

(1 tL) (41.)

(17.) (42)

(1 fL) (43.)

(10.1 (44.)

(20) (45.)

(21.) (4cL)

(22) (47 )

(23) (4tt )

(24 ) (4tL)

(25) (M.)

1tL Oeet0n presstxe 275 p* Temp. 11Xf Oct). F Hydrcx isa presecxe h(rA at temp. Oct). F

'scpplsmencet hrcnnadcn h sw teem cl esse. skcesclwe, cs drssehos mey be essed prided (1) etre ls s tR x 1t. tt) ldcnnd ten h lans 2 end 3 cn acts Data ftepcrt ls hcascsed cn cess srweL Q eesn srwet Is succored snd sw nun4>> to erwets ls reoccded st sw lcp cf ests tenn.

1Ns tenn gCXOSC) mey be cbtehed harn ew Order Dept, Astor. Rt Less Dcassc Bcsc3XO, Fetrtleld, ttf Crccy-tcCCL 0

Form N-2 FORM N-2 g3ack Pg. 2 af ~2 Certnoss Holder's Sertet Hos. SEEPAGE1 tvougn ILIA R4JAN V. PARCH pz. State PA tlag.ncc 25892-E p~ state N/A ltd.raa N/A Ws oarlty tut t>> catamants made h tda report <<e os<<act and eat tea tt>>ae7 VALVEBCNNETCAP orntame to t>> tutee d ocnatructkn ct t>> AS'ede Sactkn N. DMakn k tPT C<<tncate d Au>>rttatkn Na 2856 ae AAVE7. 15t5td oa ~w CG1lvRtL CCNFNsrra rrc.

~ C<<trbate Hctdag L t>> uzi<<attytecL hddhg s vstkt ocnsrdaekn issued by t>> ttatknet Bo<<d d Boter and pressure Yaeeet hapaoton and he State cr prtarhoe ct CALIFORNIA anct employed by HARTFQRO87E4M SQILERINBPECTTCNAND IVSURANCECQMPANY ot HARTFQRO CQNNECl7CUT h<<re hapsoted t>>ae a<<ne deecrbedhhta Date ttapcrt cn beat ct my knoatadge and bettat, t>> Cantbate Herder has tabrbated t>>ee pens cr appurtan<<a>>s h accord<<>>e erat

- /i ' . and atate tMt to t>>

t>> ASIA Code Saolkn

%. DMakn t. Each p<<t tered has been <<rhcrtted lor atamphg cn t>> date ahaan abrase By algnhg hta o<<tttoate. nettw t>> hapector rw his empkyar makes arBraray, espraeaeed a trptl<<L ocnoemhg t>> equhmant daeorbed h hta Date ttapcrc Furtwnwn nohow t>> hapeotcr ncr hie employer shat be table h any m<<e'er loran'erscnat ~orprto<<ty damage cr

~ ~ /4cjrr kae or any khd ariahg trcm cr oonecaed arch)hie hapsolkn.

~~m-xc ON sr~a ~~. ~ @~i~ I porn gtatl BrL Ihctudhg andora<<nano and state cr prov and no)

"REFER lUAlTACHEO'LETTEROFEXTHVSCARKW 771EASrIECCIlIIrfl77EE.

162B Il FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Ovmer Pennsylvania Power & Light Co. Date May 30, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One PO Box 467, Berwick, PA 18603 PMR 934077, WA C43767 Address Repair Oriiaeiaadon P.O. No.. Job No., eto.
3. Work Performed by Pennsylvania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authonzatlon No. N/A Expiration Date N/A
4. Indentification of System HIGH PRESSURE COOLANT INJECTION HPCI SYSTEM 152B CLASS II
5. (a) Applicable Construction Code III 19 7" Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Rephcements 19 89
6. Identification of Components Repaired or Rephced and Rephcement Components ASME National Board Repaired, Code Name of Replaced, or Stamped Name of Manufacturer Other Identlficathn Year Component Replacement (Yes or Manufacturer Serial No. Built No)

VALVEDISC ANCHOR S/N 2 NA HV-155F001 1975 REPLACED YES DARLING ¹ HT 4353 VALVEDISC ANCHOR U6849 NA HV-155F001 REPLACEMENT YES DARLING

7. Description of Work INSTALL NEW DISC IN VALVE HV-155F001
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure 1160 psl Test Temp. 80 'F NOTE: 'upplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8rra ln. x 11 in. (2) Informa ~

tion in items 1 through 6 on this report h included on each sheet, and (3) each sheet is numbered and the number of sheets I recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

FORM NIS-2 (Back) g Remarks CODE DATA REPORT(S) ATIACHED Appticabld Mahtrfachrrera oata Reperta td be attached CERTIFICATION OF COMPLIANCE We certify that the statements made ln the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair dr rdptacdrheht Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Date , re ~5" dr dl'a oealtrhee, Titte vp+ttc operatlohs CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof PE NSYL I and employed by A IGHT MUTUALINSURANCE CO of WA AM SSAC US S ha e ins ted the components described in this Ovmer's Report during the period to S and state that to the best of my knowledge and belief, the Ovmer has performed examinations and taken corrective measures described In this Owner's Report ln accordance with the requirements of the ASME Code,Section XI.

By signing this certilicate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any Idnd arising from or connected with this inspection.

Inspector's Signature Commissions FW Mb/9 AHI National Board, State, Province, and Endorsements Date re~&

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date May 4, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One DCP 89-9153B, WA's C33301, C33303, C33304 PO Box 467, Befwick, PA 18603 Address Repair Organiaatierr P.O. Na, Job Nra, etc.
3. Work Performed by Penns Ivania Power 8 Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Expiration Date N/A
4. Indentification of System EMERGENCY SERVICE WATER SYSTEM 154A CLASS III
5. (a) Applicable Construction Code III 19 71 Edition, thru W72 Addenda, Code Case (b) Applicable EdiUon of Section XI Utilized for Repairs or Replacements 19 80 thru tAf80 and IWF-7000 W 1982 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components r

ASME National Board Repaired, Code Name of Name of Manufacturer Replaced, or Stamped Other Identification Year Component Manufacturer Serial No. Replacement (Yes or Built No)

PIPE SUPPORT BECHTEL NIA N/A SP-HBC-139-H3 1982 REPAIRED NO PIPE SUPPORT BECHTEL NIA N/A SP-HBC-131- 1982 REPLACED NO H11 PIPE SUPPORT PP+L NIA N/A SP-HBC-131- REPLACEMENT NO H11 PIPE SUPPORT BECHTEL N/A N/A SP-HBC-139- 1982 REPLACED NO H2050 PIPE SUPPORT PP+L NIA NIA SP-HBC-139- REPLACEMENT NO H2050 PIPE SUPPORT BECHTEL NIA N/A SP-HBC-139- 1982 REPLACED NO H2051

7. Description of Work Removal, reinstallation and modification of existing pi e su orts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure NONE REQUIRED Other Pressure 'F NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8A in. x 11 In., (2) informa tlon ln items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets I recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 1001 7

FORM NIS-2 (Back)

This NIS-2 is being submitted to report pipe support work that should have been included in an Applicable Manufacturers Oats Reports to be attached NIS-2 for s stem 154A-III reviousl submitted with the Unit 1 Seventh Outa e Summa Re ort.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repa1r or replacement Type Code Symbol Stamp N/A

'ertilicate of Authorization No. N/A Expiration Date N/A Signed P Owner er s Oesipnee, T1tte Vp&uc Operations Date , 19 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State orProvinceof PE NS LVANI and employed by AR IG UTUAL INSU CE CO. of A M SS C USETTS have inspected the components described in this Ovmer's Report during the period -2 4 to />> , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures d~h~lpthis Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certilicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the g-8 >-vs examinations and corrective measures described in this Ovmer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any Idnd arising from or connected with this-ins paction.

Inspector's Signature Commissions Mf 8 5 National Board, State, Province, and Endorsements

/

Date ~g~

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date May 4, 1995 Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Susquehanna Steam Electric Station One Name DCP 89-9153B, WA's C33301, C33303, C33304 PO Box 467, Betwick, PA 18603 Address Repair Organization P.O. Na. Job Na. eto.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentificatlon of System EMERGENCY SERVICE WATER SYSTEM 154A CLASS III
5. (a) Applicable Construction Code II I 19 71 Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 thru NP80 and IWF-7000 W 1982 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Code Repaired, Replaced, or Stamped Name of Name of Manufacturer Other Identiilcatton Year Replacement (Yes or Component Manufacturer Serial No. Built No)

PIPE SUPPORT PP+L NIA NIA SP-HBC-139- 1994 REPLACEMENT NO H2051 PIPE SUPPORT BECHTEL NIA NIA SP-HBC-139- 1982 REPLACED H2001 PIPE SUPPORT PP+L NIA NIA SP-HBC-139- 1994 REPLACEMENT NO H2001 PIPE SUPPORT BEG HTEL N/A NIA SP-HBC-140-Ht 1982 REPLACED NO PIPE SUPPORT PP+L NIA SP-HBC-140-H1 1994 REPLACEMENT NO PIPE SUPPORT BECHTEL NIA N/A SP-HBC-140- 1982 REPLACED NO H2017 PIPE SUPPORT PP+L N/A N/A SP-HBC-140- 1994 REPLACEMENT H2017 PIPE SUPPORT BECHTEL NIA N/A SP-HBC-1 40- 1982 REPLACED NO H2021 PIPE SUPPORT PP+L NIA N/A SP-HBC-140- 1994 REPLACEMENT H2021 PIPE SUPPORT BECHTEL N/A NIA SP-HRC-126- 1982 REPLACED H2005 PIPE SUPPORT PP+L N/A N/A SP-HRC-126- 1994 REPLACEMENT NO H2005

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Ovmer Pennsylvania Power & Light Co. Date May 4, 1995 Two North Ninth St., Allentown, PA 18101 Sheet 3 of Address
2. Plant Susquehanna Steam Electric Station Unit One DCP 89-9153B, WA's C33301, C33303, C33304 PO Box 467, Berwick, PA 18603 Address Repair Organraairen P.O. Na, Job Na, etc.
3. Work Performed by Penns lvania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentificatlon of System EMERGENCY SERVICE WATER SYSTEM 154A CLASS III
5. (a) Applicable Construction Code III 19 71 Editkn, thni W72 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 thru Mr80 and IWF-7000 W 1982 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Component Manufacturer Replacement (Yes or Serial No. BUIII No)

PIPE SUPPORT 8ECHTEL NIA N/A SP-HRC-127-H5 1982 REPLACED 'O PIPE SUPPORT PP+L N/A N/A SP-HRC-127-H5 1994 REPLACEMENT PIPE SUPPORT BECHTEL NIA SP-HRC-130.H5 1982 REPLACED NO PIPE SUPPORT PP+L N/A NIA SP-HRC-130-H5 1994 REPLACEMENT

I'101

\

'OAM N4 lttT CXRIIFICATXHOLDRR5'TA RItOh'.T FOR NUCLEAR tART Alfie As requited by the Pttt Ylsloa QC the Ash(S Code Rtales. Sccdoa ill. D(Y. I o \

'r".

Anchor/Darlfn Valve Coot 701 Ffrst Stoa Nllfamsport, laced aea t

~ K Ãpf acaacea r

~ aaeaeca PA 17701 rh (b) ilaoafacaaaced C ~ ~~ ~5 ~ co P

5ectsl lto. cf part lfae 013570 5

IaaeKe eas eeKeae ec a acsaeeae T

aaeaear Drsarha5 prepared ar eaoaeaee ac'1 eecaaer Id. lf weaas by'nchor/Darl fn Valve H/A Co any

~ +-.'4 (g ~ipc of p<<c la,~ 'ISC HEAT SS6141 ~ SA216-NCB lcl araacell reCECocoeecroelU,~~~, CrkmJakNe&tt, Core No. Cl ~

10a-900$ F.M. GATE hl, (aaaec eeeensaaea ec eeeeaee cee aaaaea eeoc~a oee eeeaeaaeco g~

A DY SHOP ORDER ET751-1 l ~

NOTE: HO DISC HYDRO PERFORMED Te csccify Ihac dao sw~cs aaede aa dais repecc sce ccaceec aal dais ceasel pact oc eppocaeaeoce as defiacd ha che Code cso focms co che roles of c~eccceecioa ef dae ASttE Code Seecioa lIL tIhe apsttcahte Destsa speetttcactoaa aa4 saceas aspect are aoc the roasoasthQ!% ef thc ÃFT'crctftcaac Holder aar parts. Aaa Nry ccraf-icace ltotdsr for appectcmecsv b reaeaaaaihle for fsrakahiaag a aepaaaas Decima Spectftcadoa aad Stress a tactadcd la the compsacat DeQes 5pectttcactm aa4 5crws ttcpoct.l

~ af Ihe spyartwaos a aoc Dace ~~ Anchor/Darl fn I ~ aasaceea Valve Co.z Iaeaeaca AA~ d E~ CecUicsce of Aadaociacsc4ze Mo, CEKIIFICA'IIONOF DESIGN FOR APPURTENANCE (Hea aptHeabie)

~ 'e h

ahglaarr

-~t5Q; -' Desisa iafocaaioa << file ec yVfaaa ~

Serosa mlysis repen ea Qe ac Deslsa speeifksuoas certified by Nerf. Eoa. Seer acr Ne..

~>i'I stress aaalyels tepocc ceccianaed by Prof Eat.SI~ aer No.

CEFlIFICATE OF SHOP 1NSPECT10N "I,

l, che eadersisaaed, bola4as a relid eowiseia iseaed by Ihe Necioaal Booed of 24ilec aa4i Pres~ Vessel leepeccocs of ace 'teppiel che pace of a paessaae ceasel described ie ahie Parttat Data ltcsort Isa . aa4 Crate that tO the heat Cf ar kaeaatedae aad taetlef. the ftPT CCrtttlCate HOlder haa CCIIKmeted thts Part la a 5 with the ASttK Cede SCCttaa ttt, 5y sigaia5 Ibis ecccificsccr eeiaher ahe laepeecoc eor his esployer aeahes eay eacreacy, espceseed ce iotaned, coecera tag the part dcscrthed lh this parttal Data ltcport. yarthcrmorc. aclthcr thc tntpcctor aor his crsploycr p

shall be liaMe ia aay easact for aay persossl iaiscy or property diego or ~ loss ol aay kisd acic:as taeaa oc ccaseeaed j:~I'ele

<<ich Ibis isspecaioa.

Pennsylvanfa 2392

~ S aaeaaeeea aeereo Saeaer Paeeaeee care lace

~

~ seeeaeeecclea

~ Nce aaooece s e ecrveca ce ccrc lore e(

~

~, aercrerc e rare Qal ~

~ eereeee ccrg ae acre erNNCere Iaa Mececrf cr wry ~ lorecoel oe ere L

~ ace ce eccrerar EW ~ II ~ It) aeaereea~ le Iaaae I I w carl ~

ASM',SC55.4tIII SI. Noae YOak. N.Y. 10017 QI77) Ttara aerala I5000eto)IIIEY beehaalaaed taecaaatatoraaetoeOI

164A III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 12, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name PO Box 467, Berwick, PA 18603 DCP's 943023A & D; WA's C43582 & C43583 Address Repair Oreancaoon p.o. No., Job No., ero.
3. Work Performed by Pennsylvania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentiflcatton of System Emer enc Service WaterS stem 154A, Class III
5. (a) Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements19 89
6. identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Replaced, or Stamped Other Year Component Manufacturer Serial No. No. Replacement (Yes or identification Built No)

ESW SUPPLY 'TO THE BEG HTEL N/A N/A SPHBC1394 1982 REPLACED YES

'A RHR PUMP MOTOR OIL COOUNG COIL ESW SUPPLY TO THE PP&L N/A N/A SPHBC1394 1995 REPLACEMENT NO "A"RHR PUMP MOTOR OIL COOLING COIL ESW RETURN TO THE BECHTEL NIA N/A SPHBC1404 1982 REPLACED YES

'A'HR PUMP MOTOR OIL COOLING COIL ESW RETURN TO THE PP&L N/A N/A SPHBC1~ 1995 REPLACEMENT NO "A" RHR PUMP MOTOR OIL COOUNG COIL ESW SUPPLY TO THE BECHTEL NIA NIA SP H BC139-1 1982 REPLACED YES D RHR PUMP MOTOR OIL COOLING COIL ESW SUPPLY TO THE PP8L N/A N/A SPHBC139-1 1995 REPLACEMENT NO D RHR PUMP MOTOR OIL COOLING COIL

7. Description of Work Installed new ESW Inlet and Outlet Piping to "A" & "D" RHR Pump Motor Oil Coolers
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure 0 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size ls 8N in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

FORM NIS-2 (Back)

9. Remarks Applicable htanufactuiers Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Date ,19 er or s Oesitinee, Titie Vp+uc Operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof P NNSY VA IA and employed by ARKWRIGHT MU UAL INSURANC CO of WALTHAM MASSAC USETTS have spected the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has pe ormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual Engineering Assoc.

Inspector's Signature Commissions oh/

National Board, Sta e, Province, and Endorsements Date i9~5

164A III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 12, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name PO Box 467, Betwick, PA 18603 DCP's 944023A & B; WA's C43582 8 C43583 Address Repair Orgaoiaarron P.O. No., Jorr Hra. ere.
3. Work Performed by Pennsylvania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentification of System Eme enc Service Water S stem, 154A Class III
5. (a) Applicable Construction Code ASME III 19 71 Edition, thiu Vtr72 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

ESW RETURN TO THE 8ECHTEL N/A N/A SPHBC140-2 1982 REPLACED YES 0 RHRPUMPMOTQR OIL COOUNG COIL ESW RETURN TQ THE PP&L N/A N/A SPHBC'l40-2 1995 REPLACEMENT NO O RHRPUMPMOTQR OIL COQUNG COIL

1-66B-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date 9 May, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name PO Box 467, Beiv/ick, PA 18603 DCP 934069 WAIf C43389 Address Rerrarr organizaben p.cr. Ne. ~ Jeb No., etc.
3. Work Performed by Penns Ivania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A CONTROL ROD HYDRAULICS SYSTEM 155B CLASS II ASME 16448 &

Material: NF-2610 ASME Section III, 1977 Edition, thru Winter 1977 Addenda (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Replaced, or Stamped Other Year Component Manufacturer Serial No. No. Replacement (Yes or Identification Built No)

CRD SDV VENT LINE BECHTEL NONE N/A 1982 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE N/A REPLACEMENT NO SUPPORT CRD SDV VENT LINE BECHTEL NONE N/A 1N61 1982 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE IN61 REPLACEMENT NO SUPPORT CRD SDV VENT UNE NISCO NONE N/A 1S46 1981 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE N/A 1S46 REPLACEMENT NO SUPPORT

7. Description of Work THE ADDITIONAND/OR CHANGE OF STRUCTURAL MEMBERS & CLAMPS
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure N/A psi Test Temp. N/A 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 8N in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

V (12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

FORM NIS-2 (Back)

9. Remarks NONE 1tppticable Manufacturers Oats Repons to be attache9t CERTIFICATION OF COMPLIANCE We certil'y that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repas or replacement Type Code Symbol Stamp N/A Certificate of Authonzation No. N/A Expiration Date '/A Signed er or rs Oes1ttnee, TN vp+uc operattons Date 53/ ,19 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of P NSY ANI and employed by A IG UTUA SU NC CO of WA THAM MASS C US S ha e ins ed the components described in this Qvmer's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Qwner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certiftcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Qwnet's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual Engineering Assoc.

Commissions S Inspector's Signature National Board, State, Province, and Endorsements Date 19~4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Ovmer Pennsylvania Power 8 Light Co. Date 9 May, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Susquehanna Steam Electric Station Unit Two Name PO Box 467, Befwick, PA 18603 OCP 934069 WA¹ C43389 Address Reparr Orgaoizaborr p.O. No., Job No., ero.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentification of System CONTROL ROD HYDRAULICS SYSTEM 155B CLASS II ASME 16448 &

Material: NF-2610 ASME Section III, 1977 Edition, thru Winter 1977 Addenda (b) Applicable Edition of Section XI Utillaed for Repairs or Replacements 1989 No Addenda

6. IdentNcation of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement (Yes or Component Manufacturer Serial No. Identiricatlon Built No)

CRD SDV VENT LINE NISCO NONE NIA 1S53 1981 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE N/A 1S53 1995 REPLACEMENT NO SUPPORT CRD SOV VENT LINE NISCO NONE NIA 1S58 1981 REPLACED YES SUPPORT CRD SOV VENT LINE PP&L NONE NIA 1S58 1995 REPLACEMENT NO SUPPORT CRD SDV VENT LINE NISCO NONE NIA 1N58 1981 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE N/A 1N58 1995 REPLACEMENT NO SUPPORT CRD SDV VENT LINE NISCO NONE NIA 1981 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE N/A 1N57 1995 REPLACEMENT NO SUPPORT CRD SDV VENT LINE NISCO NONE NIA 1S54A 1981 REPLACED YES SUPPORT CRD SDV VENT LINE PP&L NONE NIA 1854A 1995 REPLACEMENT NO SUPPORT

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date May 12, 1995 Two North Ninth St., Allentown, PA 18101 Sheet 1 of Aridreaa
2. Plant Susquehanna Steam Electric Station Unit One Name DCP's 93-3059A, B & C; WA's C43245, C43246, PO Box 467, Befwick, PA 18603 C43250 C43251 C43255 throu h C43258 Addreaa Repair Orianrr arron P.O. No., Job No., eto.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Addreaa Expiration Date N/A
4. Indentification of System Reactor Vessel and Aux. S stem, 162A, Class I
5. (a) Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, N<"" Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement (Yes or Component Manufacturer Serial No. Identification Built No)

PIPING FROM BECHTEL NIA N/A SPDCA137< 1982 REPLACED YES NOZZLE N-12A TO PENETRATION X-59A PIPING FROM PP&L N/A N/A SPDCA137< 1995 REPLACEMENT NO NOZZLE N-12A TO PENETRATION X49A VENT FROM PP&L N/A NIA SPDCA137-5 1995 REPLACEMENT NO XY-1 D004A TO SPDCA138-1 PIPING FROM BECHTEL N/A N/A SPDCA138-1 1982 REPLACED YES NOZZLE N-11A TO P ENETRATION X45A PIPING FROM PP&L N/A NIA SPDCA138-1 1995 REPLACEMENT NO

~ NOZZLE N-11A TO PENETRATION XASA

7. Description ofwork Installed new Reactor Water Level Condensing Chambers and associated Vent Piping
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure 0 Other Pressure 1100 / 1050 psl Test Temp. 80 / 155 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8N in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

FORM NIS-2 (Back)

ASME Section III, 1977 Edition thru Summer 1979 Addenda (NB-3650) is applicable to Nuclear Applicable Manuiacturecs Data Repons to be attached Class 1 evaluation onl CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or reptacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

,19

'igned Date Owne r Owners Oesittnee, Titl Vpauc Operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by AR RIGHT MuTuAL INSuRANCE CO. of WA THAM MASSACHUS S h ve inspecte~de components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has perform examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual Engineering Assoc.

Commissions A nl/I Inspector's Signature National Board, State, Province, and Endorsements Date

162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 12, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name DCP's 9M059A, 8 & C; WA's C43245, C43246, PO Box 467, BenNick, PA 18603 C43250 C43251 C43255 throu h C43258 Address Repair oriranraabon p.o. No.. Job rro. eto.

~

3. Work Performed by Pennsylvania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentification of System Reactor Vessel and Aux. S stem, 162A Class I
5. (a) Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements19 89
6. Identitlcation of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

PIPING FROM BECHTEL N/A N/A SP DCA1 37-1 1982 REPLACED YES NOZZLE N-128 TO PENETRATION X498 PIPING FROM PP&L N/A N/A SPDCA137-1 1995 REPLACEMENT NO NOZZLE N-128 TO PENETRATION X498 VENT FROM PP&L NIA N/A SPDCA137% 1995 REPLACEMENT NO XY-1 D0048 TO SPDCA138-2 PIPING FROM BECHTEL NIA NIA SPDCA138-2 1982 REPLACED YES NOZZLE N-118 TO PENETRATION X-658 PIPING FROM PP&L NIA N/A SPDCA138-2 1995 REPLACEMENT NO NOZZLE N-118 TO PENETRATION X%58 REACTOR VESSEL BECHTEL NIA N/A SPDBA112-4 1982 REPLACED YES HEAD VENT TO STEAM LINE REACTOR VESSEL PP&L N/A N/A SPDBA112-4 1995 REPLACEMENT NO HEAD VENT TO STEAM LINE REACTOR VESSEL BEG HTEL N/A NIA SPDCA145-2 1982 REPLACED YES HEAD VENT TO PENETRATION X-59A REACTOR VESSEL PP&L N/A N/A SPDCA145-2 1995 REPLACEMENT NO HEAD VENT TO PENETRATION X-59A

162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date May 12, 1995 Two North Ninth St., Allentown, PA 18101 Sheet 3 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name OCP's 93-3059A, 8 & C; WA's C43245, C43246, PO Box 467, Berwick, PA 18603 C43250 C43251 C43255 throu h C43258 Address Reparr Organraaeon p.O. No., Jorr No., eio.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentification of System Reactor Vessel and Aux. S stem, 162A, Class I
5. (a) Applicable Construction Code ASME III 19 71 Edition, thru Vtf72 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identitlcatlon of Components Repaired or Replaced and Replacement Components ASME National Board Code Repaired, Name of No. Replaced, or Stamped Name of Manufacturer Other Identification Year Component Manufacturer Replacement (Yes or Serial No. Built No)

REACTOR VESSEL HEAD VENT TO BECHTEL NIA'IA SPDCA1454 1982 REPLACED YES PENETRATION X498 REACTOR VESSEL PP&L N/A N/A SPDCA1454 REPLACEMENT NO HEAD VENT TO PENETRATION X%98 VENT FROM XY-14202 PP&L N/A NIA SPOCA1454 1995 REPLACEMENT NO TO SPDBA112<

SPDCA145-9'995 VENT FROM PP&L N/A N/A 1995 REPLACEMENT NO XY-821-1 D002 TO SP DBA112<

PIPE SUPPORT RX BECHTEL N/A NIA SPDCA137-H7 1982 REPLACED NO BLDG INSIDE CONTAINMENT PIPE SUPPORT RX PP&L N/A N/A SPDCA137-H7 1995 REPLACEMENT NO BLDG INSIDE CONTAINMENT PIPE SUPPORT RX PP&L N/A NIA SPDCA137-H23. 1995 REPLACEMENT NO BLDG INSIDE CONTAINMENT PIPE SUPPORT RX PP&L N/A N/A SPDCA137-H24 1995 REPLACEMENT NO BLDG INSIDE CONTAINMENT PIPE SUPPORT RX PP&L N/A NIA SPDCA138-H26 1995 REPLACEMENT NO BLDG INSIDE CONTAINMENT

162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 12, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 4 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name OCP's 934059A, B 8 C; WA's C43245, C43246, PO Box 467, Berwick, PA 18603 C43250 C43251 C43255 throu h C43258 Address Reoad Orttanraaton P.O. NO., Jetr NO., ete.
3. Work Performed by Penns Ivania Power & Light Co. Type Code Symbol Stamp None.

Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A

4. Indentification of System Reactor Vessel and Aux. S stem, 162A, Class I
5. (a) Applicable Construction Code ASME III 19 71 Edition thru Vtr72 Addenda, N<11 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identilicatlon of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

PIPE SUPPORT RX PP&L N/A N/A SPDCA138-H27 1995 REPLACEMENT NO BLDG INSIDE CONTAINMENT PIPE SUPPORT RX PP&L NIA N/A SPDCA138-H28 1995 REPLACEMENT NO BLDG INSIDE CONTAINMENT PIPE SUPPORT RX BECHTEL N/A N/A SPDBA112-H28 1982 REPLACED BLDG ORYWELL PIPE SUPPORT RX PP&L N/A N/A SPDBA112-H28 1995 REPLACEMENT NO BLDG DRYWELL PIPE SUPPORT RX PP&L N/A N/A SPOBA112-H51 1995 REPLACEMENT NO BLDG DRYWELL PIPE SUPPORT RX BECHTEL NIA NIA SPDCA145-H50 1982 REPLACED BLDG ORYWELL PIPE SUPPORT RX PP&L NIA NIA SPDCA145-H50 1995 REPLACEMENT NO BLDG ORYWELL PIPE SUPPORT RX BECHTEL NIA N/A SPDCA145-H52 1982 REPLACED NO BLDG DRYWELL PIPE SUPPORT RX PP&L N/A NIA SPOCA145-H52 1995 REPLACEMENT NO BLDG DRYWELL PIPE SUPPORT RX BECHTEL NIA NIA SP DCA145-H53 1982 REPLACED NO BLDG DRYWELL PIPE SUPPORT RX PP&L N/A NIA SPDCA145-HS3 1995 REPLACEMENT NO BLDG DRYWELL

162A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 12, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 5 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name DCP's 93-3059A, B & C; WA's C43245, C43246, PO Box 467, Berwick, PA 18603 C43250 C43251 C43255 throu h C43258 Address Repair Ortrancatioir P.O. No. ~ Job No., etc.
3. Work Performed by Pennsylvania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentilication of System Reactor Vessel and Aux. S stem 162A, Class I
5. (a) Applicable Construction Code ASME III 19 71 Edition, thru Vtf72 Addenda, Code Case (b) Applicable Edition of Section XI UtiTized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year (Yes or Component Manufacturer Serial No. Built Replacement No)

PIPE SUPPORT RX PP&L N/A N/A SP DCA1 45-H70 1995 REPLACEMENT NO BLDG DRYWELL PIPE SUPPORT RX PP&L N/A N/A SPDCA145-H71 1995 REPLACEMENT NO BLDG DRYWELL

164A I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date May 12, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One Name PO Box 467, Befwick, PA 18603 DCP's 94-9088; WA C53150 Address Repair Ortiaoraabon P.O. No., Job No., eto.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentiflcation of System Recirc-Flow Control and Jet Pum Instrumentation 164A, Class I
5. (a) Applicable Construction Code ASME III 19 71 Edition, thru W72 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement (Yes or Component Manufacturer Serial No. ldentllicatlon Built No)

PIPE SUPPORT RX BECHTEL N/A N/A SP DCA1 51- 1982 REPLACED NO BLDG INSIDE H2008 CONTAINMENT PIPE SUPPORT RX PP&L NIA NIA SPDCA151- 1995 REPLACEMENT NO BLDG INSIDE H2008 CONTAINMENT

7. Description of Work Modified support to change natural frequency of drain line to valve HV-143F031B
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure None Required Other Pressure N/A psi Test Temp. N/A 'P NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8N in. x 11 in. (2) informa- ~

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept. ASME, 345 E. 47th St., New York, N. Y. 1001 7

~

FORM NIS-2 (Back)

9. Remarks Applicable Manu racturef s oats Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. reparr or reptacement Type Code Symbol Stamp N/A Certilicate of Authorization No. N/A Expiration Date N/A Signed Date ,19 er or s Oesrgnee, Trtte VP&uc operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PE SYLVANIA and employed by AR RIGHT MUTUA INSURANC CO. of WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 2 . to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described ln this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ovmer's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutua Engineering Assoc.

inspector's Signature Commissions /J National Board, State, Province, and Endorsements Date

't73AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8 Light Co. Date MAY4, 1995 rrame Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit ONE Name DCP 95-9025, WA C53262 PO Box 467, Berwick, PA 18603 Address Repair Organizadon P.O. Na, Job Na. eto.
3. Work Performed by Penns Ivania Power 8 Li ht Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentificatlon of, System PRIMARY CONTAINMENTATMOSPHERE CONTROL SYSTEM 173A CLASS II
5. (a) Applicable Construction Code ASME III 19 71 Edition, W 72 Addenda, N<t" Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 EDITION
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Replaced, or Stamped Other Year Component Manufacturer Serial No. No. Replacement (Yes or identification Built No)

PIPE SUPPORT BECHTEL N/A NIA HB8-116.H1 1982 REPLACED NO MECHANICAL PACIFIC 13424-81 N/A HBB-116-H1 1981 REPLACED SNUBBER SCIENTIFIC PIPE SUPPORT BECHTEL N/A NIA H BB-1 16-H2 1982 REPLACED PIPE SUPPORT BECHTEL N/A HBB-116-H4 1982 REPLACED NO PIPE SUPPORT BECHTEL NIA N/A SP-HBB-116- 1982 REPlACED NO H2004

7. Description of Work REMOVALOF SUPPORTS FROM HV-15703, HV-15704 8 HV-15705
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure NO TESTING REQUIRED

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 8N in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

FORM NIS-2 (Back)

IN RESPONSE TO EDR 94-002.

Applicable Msnufscturers osts Reports to be sttscned CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code,Section XI. repslf or fe~

REPLACEMENT conforms to the rules of the Type Code Symbol Stamp N/A Certilicate of Authortmtton No. N/A Expiration Date N/A Signed Date ,19 r or Oestgnee, Ttle VP&uc Operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by AR IGH A NSU NCE CO. of WAL AM ASSACHUSETTS hav in lsd the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described ln this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection Factory Mutual Engineering Assoc.

Inspector's Signature Commissions /

National Board, State, Province, and Endorsements Date isa&

173A )I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8<<Light Co. Date May 30, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Susquehanna Steam Electric Station Unit One PMR 89401 8D WA's C04388, C04389, C04390 PO Box 467, Befwick, PA 18603 C 04391 Address Repair Organraation P.O. No. ~ Job Na. ero.
3. Work Performed by Pennsylvania Power 8 Light Co. Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Expiration Date N/A
4. Indentificatlon of System CONTAINMENTRADIATION MONITORING SYSTEM 173A CLASS II
5. (a) Applicable Construction Code III 19 71 Edition, thiu W72 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serial No. Built No)

SMALLPIPE PPL NA NA SPHCB158-1 1992 REPLACED NO ASSEMBLY SMALL PIPE PPL NA NA SPHCB158-1 1994 REPLACEMENT NO ASSEMBLY SMALL PIPE BECHTEL NA SPHCB125-H7 1982 REPLACED SUPPORT SMALL PIPE PPL NA SPHCB125-H7 1994 REPLACEMENT NO SUPPORT SMALLPIPE PPL NA SPKCB158-H5 1994 REPLACEMENT NO SUPPORT SMALL PIPE PPL SPHCB159-H5 1994 REPLACEMENT NO SUPPORT

7. Description of Work INSTALLATIONAND TESTING OF 1" CRM PIPING
8. Tests Conducted: Hydrostatic Other Pneumatic Pressure 67 H Nominal Operating Pressure psi Test Temp. 88 / 90 eF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 8N In. x 11 ln., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets I recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 1001 7

FORM NIS-2 (Back)

9. Remarks Appticable Manufacturers Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or repiacernent Type Code Symbol Stamp N/A Certilicate of Authorization No. N/A Expiration Date N/A Signed Date ,19 owner era Designee, Titi vt9&uc operations CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANI and employed by AR IG U A INSURANC CO of WA AM MASSACHUS S have 'ns e components described in this Owner's Report during the period iO to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Ownet's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, examinations and corrective measures described in this Ovmer's Report. Furthermore, neither the Inspector nor concerning the his employer shall be liable in a armer for any personal inJury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature Commissions rQ National Board, State, Province, and Endorsements Date 19~&

173A II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI 1.,Owner Pennsylvania Power 8 Light Co Date May 30, 1995 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address

2. Plant Susquehanna Steam Electric Station Unit ONE Name PMR 894018D WA's C04388, C04389, C04390 PO Box 467, Berwick, PA 18603 C 04391 Address Reparr Organizadon P.O. No. ~ Job No., eto.
3. Work Performed by Penns Ivania Power & Light Co. Type Code Symbol Stamp None Name Two North Ninth St., Allentown, PA 18101 Authorization No. N/A Address Expiration Date N/A
4. Indentificatlon of System CONTAINMENTRADIATION MONITORING SYSTEM 173A CLASS II
5. (a) Applicable Construction Code II I 19 71 Edition, thru Vtf72 Addenda, Code Case (b) Applicable Edithn of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Board Repaired, Code No. Replaced, or Stamped Name of Name of Manufacturer Other Identification Year Replacement (Yes or Component Manufacturer Serhl No. Built No)

SMALLPIPE PPL NA SPHCB159-1 1992 REPLACED NO ASSEMBLY SMALL PIPE PPL NA SPHCB159-1 1994 REPLACEMENT NO ASSEMBLY SMALL PIPE PPL NA NA SPHCB160-1 1992 REPLACED ASSEMBLY SMALL PIPE PPL NA NA SPHCB160-1 1994 REPLACEMENT NO ASSEMBLY SMALL PIPE PPL NA SPHCB161-1 1992 REPLACED NO ASSEMBLY SMALL PIPE PPL NA SPHCB161-1 1994 REPLACEMENT NO ASSEMBLY SMALL PIPE PPL NA SPHCB162-1 1992 REPLACED ASSEMBLY SMALL PIPE PPL NA NA SPHCB162-1 1994 REPLACEMENT NO ASSEMBLY SMALL PIPE PPL NA NA SPHCB162-H4 l 1994 REPlACEMENT NO SUPPORT SMALL PIPE PPL NA NA SPHCB163-1 REPLACED NO ASSEMBLY SMALL PIPE PPL NA NA SPHCB163-1/ 1994 REPLACEMENT NO ASSEMBLY

FORM R-1, REPORT OF WELDED X REPAIR OR as required by the provisions of the National Board Inspection Code Q ALTERATION 184

1. Work performed by Penns ivania Power and Li ht DCP934086 WA)f C43383 (name of repair or alteraoon organizauon) (P.O. no., lob no., etc.)

Two North Ninth Street, Allentown, Pa. 18101 (address)

2. Owner Penns Ivania Power and Li ht (name)

Two North Ninth Street, Allentown, Pa. 18101 (address)

3. Location of installation Sus uehanna Steam Electric Station (name)

P.O. Box 467, Be(wick, Pa. 18603 (address)

4. Unit identification: 1T-105A Name of original manufacturer GE / HEAT TRANSFER PRODUCTS (boiler, pressure vessel)
5. Identifying nos: 264586 60425 N/A N/A 1976 (mfr's serial no.) (original Nauonal eoard no.) 0urisdlcdon no.) (other) (year built)
6. Description of work: Capped 4 existing 2 schedule 80 pipe nozzles and installed 4 new 2'chedule 80 (use back. separate sheoL or sKetch If necessary) pipe nozzles. Also capped 1 existing 1 schedule 80 pipe nozzle.

Pressure test, ifapplied N/A psl

7. Rep(acement Parts. Attached are Manufacturers'Parth( Data Reports property indentirled and s)gned by Authorizedhspectors forthe fol)owing items of this report NIA (name of parL item number, mfr's. name and identifying stamp)
8. Remarks: NONE This form may be obtained from the National Board of Boiler and Pressure Vessel inspectors, 1055 Crupper AveColumbus, OH 43229

OESIGN CERTIFICATiON The undersigned ceNIIes that the statements made in this report are correct and that the design changes described in this report conform to the requirements of the National Board Inspection Code.

ASME Certificate of Authorization no. to use the symbol expires 19, Oats 99 Signed (name of organtzatlon) (authorlze4 representadve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Commision issued by the National Board of Boiler and Pressure Vessel Inspectors and certilicate of com-petency issued by the state or province of and employed by of has examined the design change as described in this report and verifies that to the best of his knowledge and belief such change complies with the applicable requirements of the National Board Inspection Code.

By signing this certificate, neither the undersigned nor his employer makes any warrenty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal Injury, property damage or loss of any kind arising from or connected with this Inspection, except such liabNty as may be provided in a policy of in surance which the undersigned's insurance company may issue upon said object and then only in accordance with the terms of said policy.

Oata 19 gtgaad Commissions (Authorized Inspector) (National eoard (Inm. endorsements), state, provand no.) f CONSTRUCTION CERTIF(CATION The undersigned certifies that the statements made In this report are correct and that all construction and workmanship on this R A(R conform to the National Board Inspection Code.

(repair or alteradon)

Cert)I)cate of Authorization no. NIA to use the NIA symbol expires NIA 19

)

oats~48< table Mat c.tadattw W I (name of alteration organlzadon) dat cta Signed

/

orized represen dve)

CERTIFICATE OF INSPECTION The undersigned, holding a valid Commision issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of com-petency issued by the state or province of P NNSVLVAN)A and employed by AR GHT MUTUALINSU NC CO.

19~%

and state that to the best of my knowledge and belief this work has been done In accordance with the National Board Inspection Code.

By signing this certificate, neither the undersigned nor my employer makes any warrenty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or toss of any kind arising from or connected with this inspection, except such liability as may be provided in a policy of in surance which the undersigned's Insurance comp issue upon said object and then only in accordance with the terms of said policy.

Oate 19~S(gned Commissions (Autnonzed Inspector) (National Board (Incl. endorsemenzs), state. prov.. an4 no.)

FORM R-1, REPORT OF WELDED X REPAIR OR as required by the provisions of the National Board Inspection Code Q ALTERATION 184 Work performed by Penns Ivania Powerand Li ht DCP93-3088 / WA¹ C43384 (name ot repatr or alteration organiaadon) (p.O. noJob no.. etc.)

Two North Ninth Street, Allentown, Pa. 18101 (address)

2. Owner Penns Ivania Power and Li ht (name)

Two North Ninth Street, Allentown, Pa. 18101 (address)

3. Location of installation Sus uehanna Steam Electric Station (name)

P.O. Sox 467. Sefwick, Pa. 18603 (address)

4. Unit identification: 1T-105S Name of original manufacturer GE / HEAT TRANSFER PRODUCTS (boiler, pressure vessel)
5. Identifying nos: 264587 60426 N/A N/A 1976 (mfr's serial no.) (original National eoard no.) 0ullsdlcdon no.) (other) (year built)
6. Description of work: Capped 4 existing 2" schedule 80 pipe nozzles and installed 4 new 2'chedule 80 (use back, separate sheet. or sketch if necessary) pipe nozzles. Also capped 1 existing 1', sch-80 Pipe nozzle.

Pressure test, ifapplied N/A psi Replacement Parts. Attached are Manufacturers'Parthi Data Reports property identified and skp)ed by Authorized )nspectors $or the fothwing items of this report NIA (name or part. Item number, mfcs. name and Idenutyine stamp)

8. Remarks: NONE Id%8 Tttis formmay be obtained from the National Board of Boiler and Pressure Vessel inspectors, 1055 Crupper Avecolumbus, OH 43229 Rev. 5

DESIGN CERTIFICATION The undersigned certifles that the statements made in this report are correct and that the design changes described in this report conform to the requirements of the National Board Inspection Code.

ASME CeNflcate of Authorization no. to use the symbol expires 19 Oats 19 Signed (name of organlzadon) (autholtzed representauve)

CERTIFICATE OF REVIEW OF DESIGN CHANGE The undersigned, holding a valid Commision issued'by the National Board of Boiler and Pressure Vessel inspectors and cerliflcate of com-petency Issued by the state or province of and employed by of has examined the design change as described in this report and verifles that to the best of his knowledge and belief such change complies with the applicable requirements of the National Board Inspection Code.

By signing this certlflcate, neither the undersigned nor his employer makes any warrenty, expressed or implied, concerning the work described ln this report. Furthermore, neither the undersigned nor my employer shall be liab!e in any manner for any personal Injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided in a policy of In surance which the undersigned's Insurance company may issue upon said object and then only In accordance with the terms of said policy.

I data 19 gtgaad Commissions /

(Authorized Inspector) (National Board (Incr. endorsements), state, provan4 CERTIFICATION nc'ONSTRUCTION The undersigned certifies that the statements made in this report are correct and that all construction and workmanship on this R A conform to the National Board Inspection Code.

(repair or alteration)

Certificate of Authorization no. NIA to use the NIA symbol expires IA 19 oata~S'I 199$ a aaaas atastasaa a a~ Ztaaor (name of alteradon organlzatlon) o Slg utholtzed representauve)

CERTIFiCATE OF INSPECTION The undersigned, holding a valid Commision issued by The National Board of Boiler and Pressure Vessel Inspectors and certlflcate of com-petency issued by the state or province of P NNSY VAN)A and employed by AR IGHT MUTUA SURANC CO of WA AM MASS. has inspected the work described in this report on 19 and state that to the best of my knowledge and belief this work has been done in accordance with the National Board Inspection Code.

By signing this certificate, neither the undersigned nor my employer makes any warrenty, expressed or Implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection, except such liability as may be provided in a policy of ln surance which the undersigned's insurance corn ay issue upon said object and then only In accordance with the terms of said policy.

19~ Signed (Atlthorlz\d Iltspector)

Commissions (Nauonal scald (IncL endorsements), state, prov., and no.)

INTENTIONALLYLEFT BLANK (Former HAS Construction NIS-2 Forms included in D.1)

SNUBBER REPLACEMENT NIS-2 FORMS

SOBBER REPLACEMENT HIS-2 FORMS

ISI SNUBBER REPAIR AND REPLACEMENT

SUMMARY

1.0 1NTRODUCTION This summary identifies the work performed on ASME Section XI Snubbers, (Classes 1,2,3, and Safety Related Snubbers, parts for replacements, and repairs for which ISI has NIS-2 responsibility). This work was performed during the Unit 1 Eighth Refueling and Inspection Outage.

2.0 ODE COMPLIANCE

SUMMARY

Allwork on ASME Section XI items meet the requirements of IWA-4000 and IWA-7000 of ASME Section XI 1989 Edition, no Addenda.

3.0 Work in this area consists of Work Authorizations for Section XI replacements of snubbers and parts.

3.A Summary of replacements for snubbers, by System, Work Authorization Number, and Support Number (see Attachment 3.A).

3.B Summary of replacement or repair of snubber parts by System, Work Authorization Number, Support Number, and Replaced parts (see Attachment 3.B).

ATTACHMENT3.A SNUBBERS REPLACED SYSTEM WORK SUPPORT AUTHORIZATION IDENTIFICATION 024 A-III Y40085 HBCSH2 134G-III Y40258 HRC123H15 145 A-I Y40269 SPDBA103H2000 149A-II Y40315 SPGBB115H2008 Y40074 GBB104HS 150A-II Y40 103 SPDBB121H2012 152A-11 Y40166 DBB120H25 162A-II Y40265 MST22H42B Y40093 MST22H47 164B-I Y40177 DCA102H3 183 A-II Y40156 DBB104H18 Y40279 SPDBB108H2008 183D-III Y40227 GBC101H233 183 E-III H40198 SPHCC138H2008 183 F-I Y40114 SPDCA127H156 Y40114 SPDCA127H161 Y40117 SPDCA128H138 183 H-II Y40320 SPGBB134H3 Y40106 SPDBB125H3

ATTACHMENT3.B SNUBBER REPLACEMENT PARTS SYSTEM WORK SUPPORT REPLACED PARTS AUTHORIZATION IDENTIFICATION 149A-II Y40074 GBB104H8 2 Hea Hex Nuts, 1 Load Stud 149 A-II Y40076 GBB104H47 1 Hea Hex Nut 149A-II Y40079 GBB109H35 Ground Rear Bracket Weld 150B-II Y40158 DBB109H16 1 Load Stud 152A-II Y40067 EBB 102H15 Grind 1/16" off Clam Y40067 EBB 102H15 1 Load Stud, 2 Hea Hex Nuts 161B>>III Y40170 DBC102H17 1 Pivot Pin 162A-II Y40265 MST22H48 1 Load Stud, 2 Hea Hex Nuts Y40262 MST22H32 1 Load Stud, 2 Hea Hex Nuts Y40093 MST22H47 2 Hea Hex Nuts Y40145 DBA102H12 1 Pivot Pin Y40260 MST22H17 1 Load Stud, 2 Hea Hex Nuts Y40092 MST22H19 1Load Stud 1Hea Hex Nut H40198 MST22H24 1 Pivot Pin Y40093 MST22H47 1 Load Stud 164B-I Y40109 SPD CA102H20 1 Load Stud, 1 Hea Hex Nut Y40097 RWS100H49 1 Pivot Pin Y40266 RWS100H12 Grind 1/16" off Clam 173 C-II Y40333 SPHCB122H2005 1 Load stud, 1 Pivot Pin, 2 Hea Hex Nuts 183 A-I Y40120 SPD CA149H2003 2 Hea Hex Nuts Y40304 SPDCA149H2006 2 Hea Hex Nuts Y40302 SPDCA148H2010 1 Load Stud, 2 Hea Hex Nuts Y40302 SPDCA148H2009 1 Pivot Pin 183 A-II Y40151 DBB102H12A 1 Pivot Pin Y40153 DBB103H7A 1 Pivot Pin Y40154 1 Pivot Pin DBB104H13A'BC101H272 183D-III Y40081 2 Hea Hex Nuts Y40081 GBC101H193 1 Pivot Pin, Grind 1/16" Steel From Clam Y40224 GBC101H147 1 Pivot Pin Y40081 GBC101H272 1 Load Stud 183H Y40280 SPDBB124H4 1 Load Stud, 1 Pivot Pin

ar oa

~b C

SNUBBER NIS-2 FORMS 02@A-lll FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA 0 Y40085 PO Box 467, Berwick, PA 18603 Asew Orcwaaiion P.O. No.. Joir No.. eio.
3. Work Performed by Owner Type Code Symbol N/A Name Authonzation N/A Expiration Date N/A
4. Identificadon of System 024A Class III Diesel Generator B Exhaust
5. (a) Applicable Construcdon Code AS ME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer ,Board Other Identification Replaced, or Stamped Year Component Manufacturer Serial No. No. Replacement (Yes or Built No)

Mech Shock Pacific Scientific 19504 N/A HBCSH2 1981 REPLACED YES Mech Shock Arrester Pacific Scientific 19448 N/A HBCSH2 1981 REPLACEMENT YES

7. Description of Work Re laced existin snubber with same size, functionall tested re lacement snubber.

I

8. Tests Conducted:

-*a Hydrostatic Pneumatic Q Nominal Operating Pressure Q op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is SYs in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(1 2/82) This farm (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York. N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aooscacse M ahNr ecru< sr'a oar ~ Resene re oe auacnec CERTIFICATION OF COMPLlANCE We certify that the statements made in the report are correct and this replacement conforms to tho rules of the ASIVIE Code,Section XI.

Reoar er Reolaccmenc Typo Code Symbol Stamp N/A

~ h Cerdficate of Authorizadon No. N/A Expiradon Oats N/A Signed towner Oe/ner' Oesionee. Tice V.ia. ~ NUCtEAR OPGtAlloNS Oats < g /gI ,19 95 a I CERTIFICATION OF INSERYICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the."--"

State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUALINSURANCE CO. Ot WALTHAM MASSACHUSETTS have inspected tho components described, .

in this Owner's Roport during the period 03/25/95 to 05/06/95 , and state that to the host of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASIYIE Code,Section XI.

By signing this ceruficate noither tho Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabio in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio . FACTORY MUTUALENQ ASSOC.

r r

inspector's Signature Commissions 4 /J . 4 'fll National Board, State, Province, and Endorsements Oate: AF, 19~5

134G-ill FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI n

1. Owner Pennsylvania Power 5 Light Co. Date 05/18/95 Nunc Two North Ninth St., Allentown, PA 18101 Sheet 1 of Add race
2. Plant Sus uehanna Steam Electric Station Unit Nunc Maintenance/WA 0 Y40258 PO Box 467, Berwick, PA 18603 iieoair orqanrrauon p.o. No, Joe No.. eic.
3. Work Performed by Owner Typo Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. (dentil(cation of System 1-34G Class III Reactor Buildin Heatin 8t Ventilation S stem
5. (a) Applicable Construction Cods ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Reploceinonto 18 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Identification Year No. Replacement (Yes or Component Manufacturer Serial No. Built No)

Mech Shock Pacific Scient(((c 27958 N/A HRC123H15 1982 REPLACED NO Mech Shock Arrestor Pacific Scientific 28832 N/A HRC123H15 1982 REPLACEMENT NO

7. Description of work Re laced existin snubber with same size, functionall tested re lacement snubber.
8. Tests Conducted: Hydrostatic Q Pressure Pneumadc Q Nominal Operating Pressure Q oF Exempt QX psi Test Temp.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8)rr in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aoo4caoie Mantrlacttrrer'a Oat ~ Resorts to Oe attacneo CERTIFICATION OF COMPLIANCE We cerdfy that the statements made in the report are correct and this reolecament conforins to the rules of the ASME Codo, Secdon XI.

iteoarr er Reolacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Onto N/A Signed Oats ,19 95

Owner cr wner's Oesronae. litic I

v.ir. - Ituctartn opGvttlorts CERTIFICATION OF INSERVICE INSPECTION I, the undersignod, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUALINSURANCE CO. of WALTHAM MASSACHUSETTS have inspected the components described..

in this Owner's Report during the period 03/25/95 to 05/06/95 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of tho ASME Cods,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correcovo measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall bo liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio QFCTORY MUTUALENQ ASSOC.

Inspector's Signaturo Commissions /I National Board, State, Province, and Endorseinents Oate: , 19~+

FORM NIS-2 OV/NER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Date 05/18/95 Nome Two Nonh Ninth St., Allentown. PA 18101 Sheet 1 of
2. Plant Sus uehanna Steam Electric Station Unit Nome Maintenance/WA S'40269 PO Box 467, Berwick, PA 18603 Aepw Orcerrreerion p.O. No., Joir No., oto.
3. Work Performed by Owner Type Code Symbol Authorization N/A Expiration Oats
4. Identification of System 1-45A Class I Feedwater Common Dischar e
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI UtTiized for Repairs or Replacements 19 '89 No Add.
6. Idenrification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Cods Board Replaced, or Stamped Name of Name ot Manufacturer Other Identification Year No. Replacement (Yes or Component Manufacturer Serial No. Built No)

Mach Shock Pacific Scientific 12967 N/A SPDBA103H2000 1981 REPLACED No Mech Shack Arrestor Pacific Scientific 06668 N/A SPDBA103H2000 1979 REPLACEMENT No

7. Description of Work Re laced existin snubber with same size, functionall tested re lacement snubber.
8. Tests Conducted: Hydrostatic Pneumatic P Nominal Operating Pressure Q Exempt px Pressure psi Test Temp. op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8'h in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(1 2/82) This term (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th StNew York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A AooaCaole M anssl acliees's 0 ala Reoerla le be all sensa CERTIFICATION OF COMPLIANCE We cerdfy that the statements made in the report are correct and this r<<c<<~e<<conforms to tho rules of the ASME Codo,Section XI.

Reow er Reolaccrnenl Typo Code Symbol Stamp N/A Cerdficate of Authorization No. N/A Expiration Oate N/A Signed ow er oassner'e oeaionee. Title v.p. ~ NuctEAR opfRATIQNs Oats W c Z 8,19 96 CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stato or Province of PENNSYLVANIA and employed by ARKWRIGHT MiUTUALINSURANCE CO. Of, WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the pened 03/25/98 to 05/06/95 , and state that to tho best of my know(edge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certiflCato neithor the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report. Furthermore. neither tho inspector nor his employer shall bo liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

fACTORY IsIUTUAL ENG ASSOC.

Inspector's Signature Commissions iin t 4 p National Board, State, Province, and Endorsements Oats: sr' 19~8

'1 49A-ll FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Oats 05/1 8/95 Mama Two North Ninth St., Allentown, PA 18101 Shoot 1 of
2. Plant Sus uehanna Steam Electric Station Unit Noma PO Box 467, Berwick, PA 18603 Maintenance/WA ¹ Seo Sheet 3 of 3 Raow Orsarizadon p.c. No. ~ Joe No., aio.
3. Work Performod by Owner Type Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-49A Class II LPCI/SDC RHR
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Identification Year Replaced, or Stamped Component Manufacturer Serial No. No. Replacement (Yes or Built No)

Item 1 Heavy Hex Nuts Grinnsll Item ¹ 14'(1) NIA GBB104H47 REPLACED No 1 Heavy Hex Nuts Grinnsll Item ¹ 14'(1) N/A GBB104H47 '(1) REPLACEMENT NO Item 1 Load Stud Grinnell Item ¹ 13'(1) NIA 6BB104HB REPLACED NO 1 Load Stud Grinnoll Item ¹ 13'(1) N/A GBB104HB '(1) REPLACEMENT No

'tem 2 Heavy Hex Nuts Grinnell Item ¹ 14'(1) GBB104HB '(1) 'EPLACED NO 2 Hoavy Hex Nuts Grinnsll Item ¹ 14'(1) N/A GBB104H8 '(1) REPLACEMENT

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Ooscription of Work Re laced arts with sufficient replacement arts and round weld on rear bracket.
8. Tests Conducted: Hydrostatic Q Pneumatic Nominal Operating Pressure Q

-.*a si Test Temp, of NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Yi in. x 11 in., (2) informs tion in itoms 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at tho top of this form.

(12/82) This form (E00030) may bs obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A noooceine M eniilecniiel'e cele Reoerre ro Oe enecnen CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this <<on<<<<oreo~en'onforms to the rules of the ASIVIE Code,Section XI.

~ Renoir or Reotecernenc Type Code Symbol Stamp N/A Cerdficate of Authorization No. Expiration Oats N/A Signed Oats ,19 95 net or wner/e Oeeionee, tice VJ'. ~ rluotEAR OpotATIONS CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vossel inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO. of WALTHAM MASSACHUSETTS have inspected tho components described in this Owner's Report during the period 03/25/95 to 05/06/95 , and state that to the boat of my knowledgo and belief, tho Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with tho requirements of tha ASME Coda,Section XI.

By signing this cerdficate neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the examinadons snd correctivo measures described in this Owner's Report. Funhermoro, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection CTOAY MUTUAL ENQ ASSOC.

Commissions 6 8 ~all AAJ ( l Oato: F, Inspector's Signature 19~5 National Board, State, Province, and Endorsernents

'I 49A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5 Light Co. Date 05/18/95 Nome Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Sus uehanna Steam Electric Station Unit Maintenance/WA 0 See Sheet 3 of 3 PO Box 467, Berwick. PA 18603 Address Repair Oraorsoorion p.c. No., Jorr No., eis.
3. Work Performed by Owner Type Code Symbol N/A Nome Authorization N/A Address Expiration Date N/A
4. Identification of System 1-49A Class II LPCI/SDC RHR
5. (a) Applicable Construction Code ASME III 19 71 Edition, Wr72 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
e. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Identification Replaced, or Stamped Year Component Manufacturer Serial No. No. Replacement (Yas or Built No)

Xtem. 4 Grind Rear Bracket Grinnell Item 4 5'(1) N/A G88109H35 REPAIR NO Item 5 Mech Shock Arrestor Pacific 28801 N/A SPGBB115H2008 1982 - REPLACED NO Scientific Item 6 Mach Shock Arrestor Pacific 22875 N/A SPGBB115H2008 1981 REPLACEMENT No Scientific Item 7 Mech Shock Arrester Pacific 00552 N/A G88104HS 1978 . REPLACED NO Scientific Item 8 Mech Shock Arrestor Pacific 02430 NIA G88104HS 1991 REPLACEMENT No Scientific

'NOTE(1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

149A-t t FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 3 of
2. Plant Sus uehanna Steam Electric Station Unit N eroe Maintenance PO Box 467, Berwick, PA 18603 rieoer orceoLr euon p.o. rro.. Joe rro.. ~ ic.
3. Work Performed by Owner Type Code Symbol N/A Nome Authorization N/A Expiration Oats N/A
4. Identification of System 1-49A Class II LPCI/SDC RHR
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components Item (s) 'usquehanna Work Authorization Code Repair Form No.

Number Y40076 I95-149%07 Y40074 I95-1 49-001 Y40074 I95-149-001 Y40079 )95-149-065 Y40315 I95-149<21 Y40315 l95-1 49-021 Y40074 195-149-002 Y40074 l95-149-002

1 BOA-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date 05/1 8/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA 4 Y40103 PO Box 467, Berwick, PA 18603 ireoarr Orrraniaarion P.O. No., Joe No., eic.
3. Work Performed by Owner Type Code Symbol N/A N arne Authorization N/A Address Expiration Date N/A
4. IdentiTication of System 1-50A Class II RCIC Pum DSCH
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Identification Year Replaced, or Stamped Component Manufacturer Serial No. No. Replacement (Yes or Built No)

Mech Shock Pacilic Scientific 23566 N/A SPDBB121H2012 1981 REPLACED Mech Shock Arrester Pacific Scientific 21148 NIA SPDBB121H2012 1981 REPLACEMENT No

7. Description of work Replaced existin snubber with same size. functionall tested re lacement snubber.
8. Tests Conducted:

-*a Hydrostatic Pneumatic Q si Nominal operadng Pressure Test Temp.

P op NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8)ia in. x 11 in.. (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aooeceol ~ Mererre<<ttrrer'e cele A<<Cene to oe ette<<neo CERTIFICATION OF COMPLIANCE We certify that the statements made in the report aro correct and this recto<<Nlleot confortns to the rules of the ASIVIE Code, Socdon XI.

Aeoelr cr Reoleceltteflt Type Code Symbol Stamp N/A Cerdficate of Authorization No. N/A Expiradon Date N/A Signed / Oate ,19 95 ovmer

'l or owrter'e oeercrtee. Tick v.p. - NUcLEAR opGtATtoNS CERTIFICATION OF INSERVICE INSPECTION I , the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT NIUTUAL INSVRANCE CO. of WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 03/25/95 to 05/05/95 , and state that to the bast of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASiVIE Code,Section XI.

By signing this certificate neither tho Inspector nor his employer makes any warranty, exprossed or implied, concerning the examinations and corrocuvo moasures described in this Owner's Report. Funhermore, neither the Inspector nor his employor shall bo liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. FACTORY MIJTVALENQ ASSOC.

Date: 4, Inspector's Signature 19~~

Comtnissions National Board, State, Province, and Endorsements

1 62A-tt FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power 5. Light Co. Date 05/1 8/95 Nome Two North Ninth St., Allentown, PA 18101 Sheet 1 of
2. Plant Sus uehanna Steam Electric Station Unit Maintenance/WA ¹ See Sheet 3 of 3 PO Box 467, Berwick, PA 18603 Addreee Reoar Oreerer coon P.O. No., Joe No. ero

~

3. Work Performed by Owner Type Cods Symbol N/A Nome Authorization N/A Expiration Date N/A
4. Identification of System 1-52A Class II HPCI Pum Dischar e
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Appiicabls Edition of Section XI Utilized for Repairs or Replacements ta '89 No Add.

B. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Cods Board Replaced, or Stamped Nome of Name of Manufacturer Other No. Year'uilt Replacement (Yes or Component Manufacturer Serial No. Identification No)

Item 1 1 Load Stud Grinnell Item ¹ 13'(1) iN/A EBB102H15 REPLACED NO 1 Load Stud Grinnell Item ¹ 13'(1) N/A EBB102H15 '(1) REPLACEMENT NO Item 2 2 Heavy Hex Nuts Grinnell item ¹ 14'(1) N/A EBB102H15 REPLACED NO 2 Heavy Hex Nuts Grinnell item ¹ 14'(1) N/A EBB102H1 5 '(1) REPLACEMENT NO Item 3 Grind Clamp Grinneil Item ¹ 12'(1) N/A EBB102H15 REPAIR NO

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR Bull.T NOT AVAILABLE.

7. Description of Work Re laced arts with sufficient re lacement arts and round 1/16" of steel from clam .

Replaced parts w3. ~u x,m,en pa s an clroun e l.

~

8. Tests Conducted:

Hydrostatic 4

Pneumatic si Nominal Operating Pressure Test Temp. op from c1amp.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 85 in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at ths top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., Nsw York, N. Y 10017

FORM NIS-2 (8ack)

9. Remarks N/A Aooliceol ~ Ment<<ecttiler $ Octo Reoorte to Oe ettecned CERTIFICATION OF COMPLIANCE We cerdfy that the statements made in the report are correct and this reo"<<reotec<<tent conforms to the rules of the ASME Code, Secdon XI.

Reow or Reotecement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Oats N/A

~

1 Signed Owner oijow 'e Oeeittnee, Tide V.P. NUCLEAR OPGtATlONs Oate Z ~ ,19 95 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stats or Province of PENNSYLVANIA and employedby ARKWRIGHTMUTUALINSURANCE CO. of .

WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 03/25/95 to 05/06/95 ~ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ACTOAY MUTUAL KNQ ASSOC.

Inspector's Signature Commissions Itr g/rP ~ + r4' Nauonal Board, State, Province, and Endorsements l

Oats;

1 52A-ll FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1: Owner Pennsylvania Power & Light Co. Date 05/1 8/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of

2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA 4 See Sheet 3 of 3 PO Box 467, Berwick, PA 18603 Address Raearr Oreariaaeen P.O. NO., Jeir NO.. eie,
3. Work Performed by Owner Type Code Symbol N/A Name Authorization N/A Address Expiration Date N/A
4. Identification of System 1-52A Class II HPCI Pum Dischar e
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Naine of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

Item 4 Mech Shock Arrestor Pacific 2965 N/A DBB120H25 1978 REPLACED YES Scientific Mech Shock Arrestor Pacific 9459 NIA'BB120H25 1982 REPLACEMENT No Scientific

'NOTE(1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5 Light Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 3 of Addceee
2. Plant Sus uehanna Steam Electric Station Unit Nome Maintenance PO Box 467, Berwick, PA 18603 aeooo oioeoL'radon p.o. No.. Joe No eto.
3. Work Performed by Owner Type Code Symbol N/A Nome Authorization N/A Addheee Expiration Date N/A
4. Idendfication of System 1-52A Class II HPCI Pum Dischar e 5, (ai Appiicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Aeplecemente 19 '89 No Add.
6. Idendf(cation of Components Repaired or Replaced and Replacement Components Item (sl Susquehanna Work Authorizatlon Code Repair Form No.

Nunnber Y40067 I-95-152-005 Y40067 (-95-152.005 Y40067 1-95-152436 Y401 66 I-95-152-054

FORM NlS-2 OV/NER'S REPORT FOR REPAlRS OR REPLAC'EMENTS As Re uired b the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power 5. Light Co. Date 05/1 8/95 Name Two North Ninth St.. Allentown, PA 18101 Sheet 1 OF Addrcad
2. Plant Sus uehanna Steam Electric Station Unit Maintenance/WA ¹ See Sheet 5 of 6 PO Box 467. Berwick, PA 18603 Add(ace itacer Oreaazaeon P.O. No., Job No., eic.
3. Work Performed by Owner Type Code Syinbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-62A Class I Reactor Head (tt Auxilia S stems
5. (a) Applicable Construction Codo ASME lll 19 71 Edition, Wa72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '&9 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement (Yes or Component Manufacturer Serial No. Identification Built No) t tern 1 Pivot Pin Grinnell Item ¹ 6'(1) M/A DBA102H12 REPLACED NO 1 Pivot Pin Grinnell Item ¹ 6'(1) NIA DBA102H12 REPLACEMENT NO I tern 1 Load Stud Grinnell Item ¹ 13 (1) M/A MST22H17 REPLACED NO 1 Load Stud Grinnell Item ¹ 13'(1) NIA MST22H17 REPLACEMENT NO Item 2 Heavy Hex Nuts Grinnell Item ¹ 14'(1) NIA MST22H17 REPLACED No 2 Heavy Hex Nuts 6rinnell Item ¹ 14'(1) M/A MST22H17 REPLACEMENT NO

'NOTE (1)t SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Description ot Work Replaced arts with sufficient re lacement arts.

Replaced exis

8. Tests Conducted:

axing s Hydrostatic Exempt Qx er Pressure w3.

Pneumatic . Q, same s3.ze, psi u

Nominal Operating Pressure Test Temp. OF snubber.

NOTE: Supplemental sheets in farm at lists, sketches, or drawings may be used, provided (1) size is & Ya in. x 1 1 in., (2) intorms tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

,(1 2/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aesacatse Marsrractteer'sos\a Asserts te ce anacned CERTIFICATION OF COMPLIANCE We certify that the statements made in the report aro correct and this restecerneht conforms to tho rules of the ASIVIE Codo,Section XI.

Aettatr er Aecracerhent Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiradon Oats N/A Signed Owner er canner's Oesicnee. Tide V.P. ~ NUClEAR OPGlATTONS Date ~ ~~ QP, 19 95 CERTIFICATION OF INSERVICE INSPECTION I, the undorsigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO. of WALTHAM MASSACHUSETTS have inspected the components described in this Ownor's Report during the period 03/25/95 to 05/06/95 and state that to the best of my knowledge and belief, the Owner has porformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither tho Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall ba liablo in any manner for any personal injury or proporty damage or a loss of any kind arising from or connected with this inspecdon FACTORY MUTUAL ENa ASSaC.

Inspoctor's Signature Commissions 8 86 f /J j5 ArL/ //

National Board, State, Province, and Endorsernents Oatel

1 62A-I FORlVI NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Li ht Co. Date 05/1 8/95 Two North Ninth St.. Allentown. PA 18101 Sheet 2 OF Addteee
2. Piant Sus uehanna Steam Eiectric Station Unit rteme PO Box 467, Berwick, PA 18603 Maintonance/WA ¹ See Sheet 5 of 6 Aeoev otgettttetion p.c. rtoJoe No., etc.
3. Work Performed by Owner Type Code Symbol N/A Nome Authorization N/A Addkeee Expiration Date N/A
4. Identification of System 1-62A Class I Reactor Head 5 Auxilia S stems
5. (a) Applicable Construction Code ASME III 19 71 Edidon, W'72 Addenda Code Case (b) Applicable Edition of Soction XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identiftcat(on of Components Repaired or Replaced and Replacoment Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No. No. Identification Replacement (Yes or Built No)

Item 4 1 Load Stud Grinnell Item ¹13 (1) N/A MST22H19 REPLACED 1 Load Stud Grinnell Item ¹13'(1) N/A MST22H19 REPLACEMENT No Item 5 1HeavyHexNut Grinnell Item ¹14'(1) N/A MST22H19 REPLACED No 1 Heavy Hex Nut Grinnell Item ¹14'(1) NIA MST22H19 REPLACEMENT No Item 6 1Pivot Pin Grinnell Item ¹6'(1) N/A MST22H24 REPLACED No 1 Pivot Pin Grinnell Item ¹6'(1) N/A MST22H24 REPLACEMENT No 1 Load Stud Grinnell Item ¹13'(1) N/A MST22H32 REPLACED No 1 Load Stud Grinnell Item ¹13'(1) NIA MST22H32 REPLACEMENT No Item 8 2 Heavy Hex Nuts Grinnell Item ¹14'(1) NIA MST22H32 REPLACED No 2 Heavy Hex Nuts Grinnell Item ¹14'(1) NIA MST22H32 REPLACEMENT No

'NOTE(l): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date 05/'I 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 3 OF Addraaa
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA ¹ See Sheet 5 of S PO Sox 467, Serwick, PA 18603 Addraaa Reoar orcaniaauon p.o. No., Jou rro., atc.
3. Work Performed by Owner Type Code Symbol N/A riarne Authorization N/A Expiration Date N/A
4. Identificadon of System 1-62A Class I Reactor Head & Auxilia S stems
5. (s) Applicable Construcdon Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilited for Repairs or Rerrlecements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement (Yes or Component Manufacturer Serial No. Identification Built No)

Item 9 1 Load Stud 6rinneil Item ¹13'(1) NIA MST22H47 REPLACED NO 1 Load Stud Grinnell Item ¹13'(1) N/A MST22H47 '(1) REPLACEMENT NO Item 10 2 Heavy Hex Nuts 6rinnell Item ¹14'(1) NIA MST22H47 REPLACED 2 Heavy Hex Nuts Grinnell Item ¹14'(1) N/A MST22H47 '(1) REPLACEMENT NO r

Item 11 1 Load Stud 6rinnell Item ¹13 (1) NIA MST22H48 REPLACED 1 Load Stud Grinnell Item ¹13 (1) N/A MST22H48 (1) REPLACEMENT NO Item 12 2 Heavy Hex Nuts Grinnell Item ¹14'(1) NIA MST22H48 REPLACED NO 2 Heavy Hex Nuts Grinnell Item ¹14'(1) NIA MST22H48 '(1) REPLACEMENT NO

'NOTE<1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 4 op Addheee
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA 4 See Sheet 6 of 6 PO Box 467, Berwick, PA 18603 rico ar Ore area aooh P.O. No., J air No.. etc.
3. Work Performed by Owner Type Code Symbol N/A Authorization N/A Addraco Expiration Date N/A
4. Identification of System 1-62A Class I Reactor Head & Auxiliar S stems
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Roplocomoh'ts 19 '89 No Add.
6. Identification af Components Repaired or Replaced and Replacement Components 1

ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement IYes or Component Manufacturer Serial No. identification Built No)

Item 13 Mech Shock Arrestor Pacific 9525 N/A MST22H42B 1982 REPLACED No Scientific Item 14 Mech Shock Arrestor Pacific 10723 N/A MST22H42B 1983 REPLACEMENT No Scientific Item 15 Mech Shock Arrestor Pacific 4091 N/A MST22H47 1979 REPLACED NO Scientific Item 16 Mech Shock Arrestor Pacific 6940 N/A MST22H47 1980 REPLACEMENT No Scientific

'NOTEI1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

't 62A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re ljired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Oats 05/1 8/95 Norrro Two North Ninth St., Allentown. PA 18101 Sheet 5 OF
2. Plant Sus uehanna Steam Electric Station Unit N orrro Maintenance PO Box 467, Berwick, PA 18603 Addrooo Rroorr OraorLrotion p.c. No., Joo No.. ~ ra.
3. Work Performed by Owner Type Cods Symbol N/A Authorization N/A Expiration Oats N/A
4. Identification of System 1-62A Class I Reactor Head & Auxilia S stems
5. (a) Appecable Construction Code ASME III 19 71 Edition, Wr72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Aorrlacamonta 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Coinponents Item (s) Susquehanna Work Authorization Code Repair Form No.

Number Y40145 I 95-1 62-048 Y40260 19 5-1 62-045 Y40260 I95-162-045 Y40092 I95-1 62-023 Y40092 I 95-1 62-023 H40198 I95-1 62-01 1 Y40262 I95-1 62-051 Y40262 I95-1 62-051 Y40093 I95-162-010 10 Y40093 I95-162-052 Y40265 l9 5-1 62-060 12 Y40265 I95-1 62-060

1 62A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Oate 05/18/95 Nomo Two North Ninth St., Allentown. PA 18101 Sheet 6 oF Arrdreoo
2. Plant Sus uehanna Steam Electric Station Unit Nomo Maintenance PO Box 467, Berwick, PA 18603 Aooair Oreonisotion P.O. No., Joe No.. oio.
3. Work Performed by Owner Type Code Symbol N/A Homo Authorization N/A Expiration Date N/A
4. Identification of System 1-62A Class I Reactor Head 8t Auxilia S stems
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Repieceinents 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorization Code Repair Form No.

Number 13 Y40265 )95-1 62-055 14 Y40265 )95-162-055 15 Y40093 I95-1 62-009 Y40093 I95-162-009

164B-l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Date 05/1 8/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 1 of
2. Plant Susquehanna Steam Electric Station Unit Name PO Box 467, Berwick, PA 18603 Maintenance/WA ¹ See Sheet 3 of 3 Add<ceo Reoaa Organcaaon P.a. No., Job No.. ato.
3. Work Performed by Owner Type Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-648 Class I Reactor Recirculation S stem
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs ar Replacements 19 '89 No Add.
6. Identification af Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Identification Year Replaced, or Stamped Component . Manufacturer Serial No. No. Built Replacement (Yes ar No)

Item 1 1 Load Stud Grinnell Item ¹ 13'(1) NIA SPDCA102H20 REPLACED NO 1 Load Stud Grinnell Item ¹ 13'(1) N/A SPDCA102H20 REPLACEMENT No Item 2 1 Heavy Hex Nuts Grinnell Item ¹ 14'(1) N/A SPDCA102H20 REPLACED No 1 Heavy Hex Nuts Grinnell Item ¹ 14'(1) N/A 5 P DCA102H20 REPLACEMENT

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Description of work Replaced arts with sufficient re lacem nt parts and oun 1/16" rom cl m Replaced existing sn~ ex wi
8. Tests Conducted: Hydrostatic ~ Pneumatic Q Nominal Operating Pressure Q ef snubber.

NOTE: Supplemental sheets in farm of lists, sketches, or drawings may be used, provided (1) size is 8/i in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this farm.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aopticeol ~ M entilectvier'e octo Reoorte lo oe eltecned CERTIFICATION OF COMPLIANCE We certify that tho statements made in the report are correct and this <<~rr<<otecernent conforms to the rules of the ASME Code, Secdon XI.

Renw or Reoiecernent Typo Code Symbol Stamp N/A

~ ~

Cord/Icato of Authorizadon No. N/A Expiradon Date N/A Signed Owner or owner'e eeietnee, Title V.P. ~ NVCLEAR OPERATIONS Oato 2-g-, 19 95 CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the Notional Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAl. INSURANCE CO. of.

WALTHAM MASSACHUSETTS havo inspected the components described-in this Ovrnor's Report during the period 03/25/95 to 05/06/95 , and state that, to tho best of my knowledge and belief, the Owner has por/ormod examinadons and taken corrective measures described in this Owner's Report in accordance with the requiremonts of the ASME Cade,Section XI.

By signing this cortiticate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinadons and corrective moasuros described in this Owner's Report. Funhermoro, neither tho Inspector nor his employer shall be liablo in any manner for any personal injury or property damage or a lass of any kind arising from or connocted with this inspection. CTdAY MUTUALENQ ASSdd.

Commissions 8'& /

Inspector's Signature National Board, State, Province, and Endorsements Oats:

1 648-l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI Pennsylvania Power 5 Light Co. Date 05/18/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address

2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA ¹ See Sheet 3 of 3 PO Box 467, Berwick, PA 18603 Address Raoarr Orcaraaarrora p.c. rro, Joir Noetc.
3. Work Performed by Owner Type Code Symbol N/A Authorization N/A Expiration Date N/A
4. Ident(fication of System 1-64B Class I Reactor Recirculation S stem
5. (a) Applicable Construction Coda ASME III 19 71 Edition, W'72 Addenda N/A Code Case (b) AppEcable Edition of Section XI Utilized for Repairs or Rarrlacamanis 19 '89 No Add.
6. Identii)cat(on of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Naine of Manufacturer Board Other Identification Year Replaced, or Stamped Component Manufacturer Serial No. No. Replacement (Yes or Built No)

Item 3 1 Pivot Pin Grinnell Item ¹6'(1) N/A RWS100H49 REPLACED No 1 Pivot Pin Grinnell Item ¹6'(1) N/A RWS100H49 '(1) REPLACEMENT NO Item 4 Grind Clamp Grinnell Item ¹12'(1) N/A RWS100H12 REPAIR NO ITem 5 Mech Shock Arrester Pacific 7227 NIA OCA102H3 1978 REPLACED YES Scientific Mech Shock Arrestor Pacific 19548 N/A OCA102H3 1981 REPLACEMENT YES Scientific

'NOTE(l): SERIAL/HEAT NUMBER ANO YEAR BUILT NOT AVAILABLE.

1 648-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Oate 05/18/95 ri arne Two North Ninth St., Allentown. PA 18101 Sheet 3 of
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance PO Box 467, Berwick, PA 18603 Addreaa Aeow orcaniaarion p.o. rio.. Joe Ho.. eie.
3. Work Performed by Owner Type Code Symbol N/A Mama Authorization N/A Expiration Oate N/A
4. Identification of System 1-648 Class I Reactor Recirculation S stem
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Itoplocomente 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorization Code Repair Form No.

Nuinbsr Y40109 I95-164-049 Y40109 l95-1 64-049 Y40097 I95-1 64-008 Y40266 l95-164-066 Y40177 I95-183-030

1 73 C-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Data 05/1 8/95 Two North Ninth St., Allentown. PA 18101 Sheet 1 of
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA S'40333 PO Box 467, Serwick, PA 18603 AdCheaa Ranair crcanitaaon p.c. No.. Jab No.. ate.
3. Work Performed by Owner Type Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-73C Class II Containment Atmos here Control S stem
5. (a) Applicable Construction Cods ASME III 19 71 Edition, W'72 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Cods Name of Name of Manufacturer Board Other Identification Year Replaced. or Stamped Component Manufacturer Serial No. No. Built Replacement (Yss or No) 1 Load Stud Grinnell Item 0 13'(1) N/A SPHCB122H2005 '(1) REPLACED NO 1 Load Stud Grinnell Item Si 13'(1) N/A SPHCB122H2005 '(1) REPLACEMENT NO 1 Pivot Pin Grinnell Item f 6'(1) N/A SPHCB122H2005 '(1) REPLACED NO 1 Pivot Pin Grinnell Item S(1) NIA SPHCB122H2005 '(1) REPLACEMENT NO 2 Heavy Hex Nuts Grinnell Item Il 14'(1) NIA SPHCB122H2005 a(1) REPLACED NO 2 Heavy Hex Nuts Grinnsll Item 4 14'(1) N/A SPHCB122H2005 (1) REPLACEMENT No

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Description of Work Re laced parts with sufficient re lacement arts.
8. Tests Conducted: Hydrostatic Pneumatic P Nominal Operating Pressure Q Exempt PX Pressure psi Test Temp. ef NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8A in. x 11 in.. (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this farm.

(12/82) This form (E00030) may be obtained from ths Order Dept., ASME, 345 E. 47th St., Nsw York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Antteceet ~ Metettecttttet e Oet ~ Aenette te tte ettecnee CERTIFICATION OF COMPLIANCE We certify that the statements made in the report aro corroct and this tedecement conforms to the rules of the ASME Code,Section XI.

Aennt et Aentecement Type Cade Symbol Stamp N/A Certificate of Authorizyion No. N/A Expiration Oats N/A Signo Date ,19 95 t

net et a ne/'e oeetttnee. Title v.p. ~ NUcLEAR optRATioNs CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors end the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO. of WALTHAM MASSACHUSETTS have inspected the components described in this Owner's Report during the period 03/25/95 to 05/06/95 , end state that to the bast of my knowledge and belief, the Owner has performed examinations and takon corrective measures described in this Ownor's Report in accardanco with the requiremonts of the ASME Cade,Section XI.

By signing this certificate neither tho Inspector nor his employer makes any warranty, exprossed or implied, concerning the examinations and corroctivo moasuros described in this Owner's Roport. Furthermore, noither tho Inspoctor nor his employer shell bo liable in any mannor for any porsonal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACTORY MUTUALENQ ASSOC.

Commissions Inspector's Signature National Board, State, Provinco, and Endorsoments Oats: I 19

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet of Address
2. Plant Sus uehanna Steam Electric Station Unit MaintenancelWA S See Sheet 3 of 3 PO Sox 467, Serwick, PA 18603 Address Aeosit ordsrsssuon p.o. iio.~ Jou iio., sic.
3. Work Performed by Owner Type Code Symbol N/A Authorization N/A Expiration Date N/A
4. Identification of System 1-83A Class I Main Steam Lines
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Casa (b) Appiicabla Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Board Replaced, or Stamped Name of Name of Manufacturer Other Identification Year No. Replacement (Yes or Component Manufacturer Serial No. Built No)

RBII) l. 2 Heavy Hex Nuts Grinnell Itein 4 14'(1) N/A SPOCA149H2003 '(1) REPLACED NO 2 Heavy Hex Nuts Grinnell Item 4 14'(1) N/A SPDCA149H2003 '(1) REPLACEMENT No 2 2 Heavy Hex Nuts Grinnell Item S'4'(1) N/A SPDCA149H2006 '(1) REPLACED NO 2 Heavy Hex Nuts Grinnell Item 4 14 (1) N/A SPOCA149H2006 '(1) REPLACEMENT 1 Load'Stud Grinnell Item // 13 "(1) N/A SPDCA148H2010 '(1) REPLACED NO 1 Load Stud Grinnell Item 4 13'(1) N/A SPDCA148H2010 (1) REPLACEMENT No

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Description of Work Re laced arts with sufficient re lacement arts.
8. Tests Conducted: Hydrostatic Pneumatic Q Nominal Operating Pressure Q Exempt Qx Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/s in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(12/82) This form (E00030} may be obtained from the Order Dept., ASM'E, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aoodcebte Menurecttrrer' oete Reoorte te tre ettecned CERTIFICATION OF COMPLIANCE Wo cortify that the statements made in the report are correct and this reelecernent conforms to the rules of the ASME Ccdo,Section XI.

Aeoerr er Reolecernent Typo Code Symbol Stamp N/A Certificate of Authorization Nc.

Signed rQ wner Oerner' Oeeetnee. Tide N/A V.p. NVCLEArtCptRAttcMS Expiration Oste Qsts ~~ 2. /, N/A 19 95 CERTIFICATION OF INSERVICE INSPECTION I~ the undersigned, holding a valid commission issued by tho National Board of Boiler and Pressure Vessel Inspectors and the Stato or Provinco cf PENNSYLVANIA and employed by ARKWRIQHT MUTUAL INSURANCE CO. of WALTHAM MASSACHUS~S have inspected the components described in this Owner's Report during tho period 03/25/95 tc 05/06/95 , and state that to the bast of my knowledge and bolief, the Owner has porformed examinations and taken corrective measures doscribed in this Owner's Report in acccrdonce with the requirements of tho ASME Ccdo,Section XI.

By signing this certificate neither the Inspector nor his emplcyor makes any warranty, exprossed or implied, concerning the exominations and ccrroctivo measures described in this Owner's Report. Furthermore, neither tho Inspector ncr his employer shall be liablo in an manner for any personal injury or property damago or a loss of any kind arising from or ccnnoctod with this inspectic .

FA ORY MUTUALENO ASSOC.

Inspector's Signature Commissions Ps x 5 National Board, State, Province, and Endcrsements Date:

1 83A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Li ht Co. Date 05/1 8/95 Two North Ninth St., AIIentown, PA 18101 Sheet 2 of
2. Plant Susquehanna Steam Electric Station Unit PO Box 467, Berwick, PA 18603 Maintenance/WA ¹ See Sheet 3 of 3 Ace heee Recce Ocgeoiseeon p.O. No., Joe No., eic.
3. Work Performed by Owner Type Cods Symbol N/A iieme Authorization N/A Expiration Date N/A
4. Identification of System 1-83A Class I Main Steam Lines
5. (s) Applicable Construcdon Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replecements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Identification Year Replaced, or Stamped Component Manufacturer Serial No. No. Built Replacement (Yes or No)

Item 4 2 Heavy Hex Nuts Grinnell Item ¹ 14'(1) NIA SPDCA148H2010 REPLACED NO 2 Heavy Hex Nuts Grinnell Item ¹ 14'(1) N/A SPDCA148H2010 REPLACEMENT No e

5 1 Pivot Pin Grinnell Item ¹ 6'(1) NIA SPDCA148H2009 REPLACED NO 1 Pivot Pin Grinnell Item ¹ 6'(1) N/A SPDCA148H2009 REPLACEMENT NO

'NOTE(1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Li ht Co. Date 05/1 8/95 Nome Two North Ninth St.. Allentown, PA 18101 Sheet 3 of Aeeieee
2. Plant Susquehanna Steam Electric Station Unit Nome Maintenance PO Box 467, Berwick, PA 18603 Reoeo Ozgenixeiion P.O. No., Joe No., eto.
3. Work Performed by Owner Type Coda Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-83A Class I Main Steam Lines
5. ia) Applicable Construction Code ASME Itl 19 71 Edition, tw'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identlficaoon of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorization Code Repair Farm No.

Number Y40120 I95-183<04 Y40304 I95-183-038 Y40302 195-183-040 Y40302 l95-183%40 Y40302 I95-183<41

't 83A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 8t Light Co. Date 05/1 8/95 Nome Two North Ninth St., Allentown, PA 18101 Sheet 1 of
2. Plant Sus uehanna Steam Eiectric Station Unit Noma Maintenance/WA 4 See Shoot 3 of 3 PO Box 467, Berwick, PA 18603 Address Recorr Orcorssouon p.c. No.. Jou No, eic.
3. Work Performed by Owner Type Code Symbol N/A Nemo Authorization N/A Expiration Date N/A
4. Identification of System 1-83A Class II Main Steam Lines
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 18 '89 No Add.

B. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No) tern 1 1 Pivot Pin Grinnell Item 0 6'(1) NIA DBB102H12A (1) REPLACED No 1 Pivot Pin Grinnell Item O' (1) N/A OBB102H12A '(1) REPLACEMENT NO Teal 2 1 Pivot Pin Grinnoll Item 4 6'(1) N/A OBB103H7A REPLACED NO 1 Pivot Pin Grinnell Item 4 6 (1) NIA DBB103H7A REPLACEMENT NO Tettt 3 1 Pivot Pin 6rinnell Item 0 6 (1) N/A OBB104H13A REPLACED NO 1 Pivot Pin Grinnell Item 4 6'(1) N/A DBB104H13A REPLACEMENT NO

'NOTE (1): SERIAL/HEAT NUMBER ANO YEAR BUILT NOT AVAILABLE.

7. Ooscription of Work Re laced arts with sufficient replacement arts.
8. Tests Conducted: Hydrostatic Pneumatic Q Nominal operating Pressure Q Exempt Qx Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informs tion in items 1 through 6 on this repon is included on each sheet, and (3) each sheet is numbered and the number of sheets i rocorded at the top of this form.

(1 2/82) This form (E00030) may bo obtained from the Order Dept., ASME, 345 E. 47th St., Now York, N. Y 10017

FORM NIS-2 (Bacit)

9. Remarks N/A Aoooosee M uwisenees' Os(s Aeoons <o oe ~ e sensa CERTIFICATION OF COMPLIANCE We certify that the statements made in tho report are correct and this '~<<erne<<conforms to the rules of the ASME Code,Section XI.

Reow or Reolscemenr Type Codo Symbol Stamp N/A Certificate of Authorization No. '/A Expiration Date N/A Sign Date Owner osjo ner'e Oendnee. Tide V.P. ~ Nuctann OPERAtIONS CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Prossure Vessel Inspectors and the Stats or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUALINSURANCE CO. of. ~

WALTHAM MASSACHUSEYI'S have inspected the components described>>

in this Ownor's Report during the period 03/25/95 to 05/06/95 , and state that, to tho best of my knowledgo and belief, the Owner has performed examinations and taken corrective measures described in ...

this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cerriflcate neither tho Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons end corrective measures described in this Owner's Report. Furthermore. neither the inspector nor his employer shall be liablo in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ACTORY MUTUALEIIQ ASSOC.

Commissions Inspector's Signature National Board, State, Province, and Endorsements Date: , 19~M

1 83A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Date 05/1 8/95 N NEO Two North Ninth St., Allentown, PA 18101 Sheet 2 of
2. Plant Sus uehanna Steam Electric Station Unit N emu MaintensncelWA O'ee Sheet 3 of 3 PO Box 467, Berwick. PA 18603 Addicts Aeue i oidenzsuon p.o. Mo., Jou Nd., oid.
3. Work Performed by Owner Type Code Symbol N/A NMlu Authorization N/A Expiration Date N/A
4. Identification of System 1-83A Oass il Main Steam Lines
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case Ib) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Nsine of Name of Manufacturer Board Other Identification Year Replaced, or Stamped Component Manufacturer Serial No. No. Replacement IYes or Built No) tern 4 Mech Shock Arrestor Pacific Scientific 'I 7243 NIA SPOBB108H2008 1983 REPLACED NO Mech Shock Arrestor Pacific Scientific 13433 NIA SPDBB108H2008 1981 REPLACEMENT NO tern 5 Mech Shock Arrestor Pacific Scientific 02422 NIA 088104H18 1990 REPLACED No Mech Shock Arrester Pacific Scientific 00552 NIA 088104H18 1973 REPLACEMENT NO

'NOTEI1): SERIAL/HEAT NUMBER AND YEAR BUILT NQT AVAILABLE.

I 83A-ll FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Oats 05/1 8/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 3 of Address
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance PO Box 467, Berwick, PA 18603 Address Reparr Oreaeiaation P.O. No., Joe No., ~ ic.
3. Work Performed by Owner Type Code Symbol N/A Name Authorization N/A Expiration Oats N/A
4. Identification of System 1-83A Class II Main Steam Lines
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorization Code Repair Form No.

Number Y40151 I95-183-056 Y40153 I95-183<42 Y40154 (9 5-1 83-043 Y40279 I95-183-026 Y40156 l95-183-063

1 83D-ill FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power &, Light Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 1 of Address
2. Plant Sus uehanna Steam Electric Station Unit N arne Maintenance/WA ¹ See Sheet 3 of 3 PO'Sox 467, Serwick, PA 18603 Repair Orqaniaapon P.O. No., Jerr No. ~ ~ ie.
3. Work Performed by Owner Typo Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-830 Class III Main Steam S stems
5. (s) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Coda Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Codo Name of Name of Manufacturer Board Other Replaced, or Stamped Year Component Manufacturer Serial No. No. Replacement (Yes or Identification Built No) tern 1 2 Heavy Hex Nuts Grinnell Item ¹ 14'(1) N/A GBC101H272 '(1) REPLACED No 2 Heavy Hex Nuts Grinnell Item ¹ 14 (1) N/A GBC101H272 '(1) REPLACEMENT NO
tern 2 1PivotPin Grinnell Item ¹ 6'(1) NIA GBC101H193 REPLACED No 1 Pivot Pin Grinnell Item ¹ 6'(1) N/A GBC101H193 '(1) REPLACEMENT No r

tern 3 Grind Clamp Grinnell Item ¹ 12'(1) NIA GBC101H193 REPAIR No

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Description of Work Re laced arts with sufficient replacement arts and round 1/16" of steel from clam Replaced existing spqbber with game s3.ze, unct3.ona es e rep acement
8. Tests Conducted: Hydrostatic Exempt Qx

~ Pressure Pneumatic g psi Nominal Operating Pressure Test Temp. ef snubber.

NOTE: Supplemental sheets in form af lists, sketches, or drawings may be used, provided (1) size is 8)rs in. x 11 in., (2) informs tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number af sheets i recorded st the top of this form.

(1 2/82) This farm (E00030) may be obtained fram the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 IBack)

9. Remarks N/A Aooscable M anadacturer's Oal ~ Reoens re be aoacnec O'ERTIFICATION OF COMPLIANCE We certify that the statements mado in the report are correct and this <<PNrr<<oracam<<c conforms to the rules of the ASME Code,Section XI.

Reow er Reolacemenc Type Code Symbol Stamp N/A Certilicato of Authorization No. N/A Expiration Oats N/A Sighted Oato ,19 95 Owner Ov/ner's Oeseonee. lido V.P. NUCLEAR OPGlAlloNS r /

CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIQHT MUTUALINSURANCE CO. of WALTHAM MASSACHUSETTS have inspected the components described" in this Owner's Report during the period 03/25/95 to 05/06/95 , and state that, to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cerificate neither the Inspector nor his employor makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall bo liable in sny manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. F CTCAY MUTUAL ENQ ASSOC.

Commissions u'//

Inspector's Signature Nauonal Board, State, Provinco, and Endorsements Oatet . IS~M

1 83D-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power & Light Co. Data 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 2 of Adokeaa
2. Plant Sus uehanna Steam Electric Station Unit Name PO Box 467, Berwick, PA 18603 Maintenance/WA f See Sheet 3 of 3 Reoaa Otsanitaoon P.O. No., Joe No eio.
3. Work Performed by Owner Type Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-83D Class III Main Steam S stems
5. (a) Appiicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or iteplocomonts 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

Item 4 1 Pivot Pin Grinnell Item /r 6'(1) N/A GBC101H147 '(1) REPLACED No 1 Pivot Pin Grinnell Item 4 6 (1) N/A GBC'I 0 1 H147 '(1) REPLACEMENT NO Item 5 1 Load Stud Grinnell Item 4 13 (1) N/A GBC101H272 '(1) REPLACED No 1 Load Stud Grinnell Item f/ 13'(1) N/A GBC'l01H272 '(1) REPLACEMENT NO Item 6 Mach Shock Pacific, Scientific 1332 N/A GBC101H233 1978 REPLACED NO Mech Shock Arrester Pacific Scientific 10888 N/A GBC101H233 1982 REPLACEMENT No

'NOTE(l): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

1 83D-II1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power 5. Light Co, Date 05/1 8/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 3 of Ad dr oaa
2. Plant Sus uehanna Steam Electric Station Unit N arne Maintenance PO Box 467, Berwick, PA 18603 Repair Orrrarerauon P.O. No.. Jorr Noeic.
3. Work Performed by Owner Type Code Symbol N/A Authorization N/A Addheaa Expiration Oats N/A
4. Identification of System 1-830 Class III Main Steam S stems
5. (a) Applicable Construction Cods ASME III 19 71 Edition, W'72 Addenda Code Casa (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorization Code Repair Form No.

Number Y40081 I95-183<46 Y40081 I95-183-047 Y40081 I95-183-047 Y40224 I95-183-044 Y40081 I95-183-022 Y40277 I95-183-062

'1 83 E-I I I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5 Light Co. Date 05/1 8/95 Home Two North Ninth St., Allentown. PA 18101 Sheet 1 of Address
2. Plant Sus uehanna Steam Electric Station Unit Meme Maintenance/WA s'40198 PO Box 467, Berwick. PA 18603 Address Rerrerr Cr genre eden P.O. Ho., Joe No.. eic.
3. Work Performed by Owner Type Code Symbol N/A Nome Authorization N/A Expiration Date N/A
4. Identification of System 1-83E Class III Main Steam S stem
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Aoplacomcnts tg '89 No Add.
6. Identificat(on of Components Repaired or Replaced and Replacement Coinponents ASME National Repaired, Code Name of Name of Manufacturer Board Other Identification Year Replaced, or Stamped Component Manufacturer Serial No. No. Replacement (Yes or Buiit No)

Mech Shock Pacific Scientific 16396 N/A SPHCC138H2008 1980 REPLACED No Mech Shock Arrestor Pacific Scientific 23570 N/A SPHCC138H2008 1981 REPLACEMENT No

7. Description of Work Re laced existin snubber with same size, functionall tested re lacement snubber.
8. Tests Conducted: Hydrostatic Pneumatic Q Nominal Operating Pressure Q

-.* o oF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8)rr in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets i recorded at the top of this form.

(1 2/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St. New York, N. Y ~

10017

FORM NIS-2 Iaack)

9. Remarks N/A
  • Dtteeeel ~ rrtenureeturer ~ oet ~ Reoerte te ee ~ ttecned CERTIFICATION OF COMPLIANCE We certify that the statements made in tho report aro correct and this conforms to the rules of the ASME Code,Section XI.

Rettw er Aettteeement Type Code Symbol Stamp N/A Cerdficate of Authojzadon No.

Sign owner owner'e l Oeetotee. litte N/A v.rt. - Nuctsrtrt opERAttorts Expiration Date Date t, r.~ + f, N/A 19 95 CERTIFICATION OF INSERVICE INSPECTION I, tho undersigned, holding a valid commission issued by the National Board of Bailer and Pressure Vessel inspectors and the State or Province of PENNSyLVANIA and employed by ARKWRICHT MUTUAL INSURANCE CO. ot WALTHAM MASSACHUSEITS have inspected the components described'n this Owner's Report during the period 03/25/95 to 05/06/95 , and state that, to the best of my know(edge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. yp,croRv MUTUAL ENa assoc.

Commissions AJ8' .~Ah 4'lAJ/I Inspector's Signature National Board, State, Province, and Endorsements Date: C~ WZ, 19~&

't 83F-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power & Light Co. Date 05/18/95 Name Two North Ninth St., Allentown. PA 18101 Sheet 1 of Addraaa
2. Plant Sus uehanna Steam Electric Station Unit Name Maintenance/WA S'ee Sheet 2 of 2 PO Sox 467, Serwick, PA 18603 Aedarr Organiaatian P.O. NO., Jab Ne.. ere.
3. Work Performed by Owner Type Code Symbol N/A Name Authorization N/A Expiration Date N/A
4. Identification of System 1-83F Class I Main Steam S stem S. (a) Applicable Construction Code ASME III 19 71 Edition, Wr72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Rcplccaments 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Board othor Year Replaced, or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

.tern 1 Mech Shock Arrester Pacific Scientific 4191 N/A S POCA1 27H1 56 1978 REPLACED YES Ltem 2 Mech Shock Arrestor Pacific Scientific 23591 NIA SPOCA127H156 1981 REPLACEMENT NO

'.tern 3 Mech Shock Arrestor Pacific Scientific 23571 NIA SPDCA127H161 1978 REPLACED NO

.tern 4 Mech Shock Arrestor Pacific Scientific 27922 N/A SPOCA127H1 61 1982 REPLACEMENT NO "tern 5 Mech Shock Arrestor Pacific Scientific 10948 NIA SPOCA128H138 1979 REPLACED NO Etem 6 Mech Shock Arrester Pacific Scientific 16424 N/A SPDCA128H138 1980 REPLACEMENT NO

7. Description of Work ReplaCed eXiStin SnubberS With Same SiZe, funCtiOnall teSted replaCement SnubberS.
8. Tests Conducted: Hydrostatic Pneumatic Q Nominal Operating Pressure Q Exempt px Pressure psi Test Temp. ef NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 ja in. x 11 in.. (2 informs-tion in items 1 through 6 on this report is included on each sheet. and (3) each sheet is nuinbered and the number o sheets is recorded at the top of this farm.

(12/82) This form. (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y 10017

FORM NIS-2 (Back)

9. Romarks N/A Appaoaaae Manarracrurv' Oara Aepona ao Oe aoaoneo CERTIFICATION OF COMPUANCE Wo cerdfy that tho statements made in the report are correct and this repraeemenr conforms to the rules of the ASIjriE Code,Section XI.

Repw v Replacemenc Typo Code Symbol Stamp N/A Certificate of Authorizadon No. N/A Expiration Oate N/A Signed ,19 95 Owner Ow 'a Oenpnee. Tide V.P. NUCt&IR OptitATtoNS CERTIFICATION OF INSERVICE INSPECTION J

I, tho undorsigned, holding a valid commission issued by tho Nadonal Board of Boiler and Pressure Vessel inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO. of WALTHAM MASSACHUSETTS have inspected tho components described in this Owner's Report during tho period 03/25/95 to 05/06/95 , and state that to tho best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Ownor's Report in accordance with the requirements of the ASIVIE Codo,Section XI.

By signing this ceaificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correctivo measuros described in this Owner's Report. Furthermore. neither tho Inspector nor his employer shall bo liable in any mannor for any personal injury or property damage or a loss ot any kind arising from or connected with this inspection.

FACTORY MUTUAL ENQ ASSOC.

Commissions KiQ C, P4S/9 Inspector's Signature Nagonal Board, State, Province, and Endorsements

183F-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power 5. Light Co. Oats 05/18/95 Name Two North Ninth St., Allentown, PA 18101 Sheet 2 of Addi<<a<<
2. Plant Sus uehanna Steam Electric Station Unit Maintenance PO Box 467, Berwick, PA 18603 Addio<<a Reoaia Ores6<<aden P.O. No.. doe Noet<<.
3. Work Performed by Owner Type Cods Symbol N/A Name Authorization N/A Expiration Oats N/A
4. Identification of System 1-83F Class I Main Steam S stem
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement<< 19 '89 No Add.
6. Identificadon of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorizadon Code Repair Farm No.

Number Y40'114 l95-183-01 5 Y40114 (95-183-015 Y401 14 195-183-01 6 Y40114 !95-183.01 6 Y401 17 195-183.014 Y401 17 l95-183-014

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired by the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power (It Light Co. Oats 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 1 of Addrees
2. Plant Sus uehanna Steam Electric Station Unit Maintenance/WA ¹ See Sheet 3 of 3 PO Box 467, Berwick, PA 18603 Reoeii Orqenrreaon p.c. Ho. ~ Joir Ho., eio.
3. Work Performed by Owner Type Code Symbol N/A Nome Authorization N/A Address Expiration Date N/A
4. Identification of System 1-83H Oass II Main Steam S stems
5. (a) Applicable Construction Code ASME III 19 71 Edition, W'72 Addenda Code Casa (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Coinponents ASME National Repaired, Code Board Replaced, or Stainped Name of Naine of Manufacturer Other Year No. Replacement (Yes or Component Manufacturer Serial No. Identification Built No) tern 1 1 Load Stud Grinnell Item ¹ 13 (1) N/A SPDBB124H4 REPLACED NO 1 Load Stud Grinnell Item ¹ 13'(1) N/A SPOBB124H4 '(1) REPLACEMENT NO tern 3 1 Pivot Pin Grinnell Item ¹ 6'(1) N/A SPDBB124H4 '(1) REPLACED No tern 4 1 Pivot Pin Grinnell Item ¹6 (1) N/A SPDBB124H4 '(1) REPLACEMENT NO

'NOTE (1): SERIAL/HEAT NUMBER AND YEAR BUILT NOT AVAILABLE.

7. Description of Work Re laced arts with sufficient re lacement arts.

Replaced ex3.staring spy ers w3. ~arne s3.ze, unc 3. ent

8. Tests Conductedt Hydrostatic Exempt Qx

~ Pressure Pneumatic g psi Nominal Operating Pressure Test Temp.

Q op snubbexs.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8)rr in. x 11 in., (2 informs-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York. N. Y 10017

FORM NIS-2 (Back)

9. Remarks N/A Aooiiaaole M anuiacaiirar' cata Raoona ro oe err acned CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Cade,Section XI.

Raow or Raoraearnanr Typo Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Oate ,19 95 Owner Ow 'a Oeairrnae. jide V.P. ~ NUCLEAR OPGlATlorra p

CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressuro Vessel inspectors and the State or Province of PENNSYLVANIA and employed by ARKWRIGHT MUTUAL INSURANCE CO. of WALTHAM MASSACHUSETl S have inspected the components described in this Ownor's Report during the period 03/25/95 to 05/06/95 , and state that to tho bost of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the oxaminadons and correctivo measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ACTOIty MUTUALENQ ASSOC.

Inspector's Signature Commissions M(/

National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Re uired b the Provisions of the ASME Code Section XI

1. Owner Pennsylvania Power, Itt Li ht Co. Date 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 2 of Address
2. Plant Susquehanna Steam Electric Station unit Maintenance/WA Ir See Sheet 3 of 3 PO Box 467, Berwick, PA 18603 Address Repair Ordaniraoon p.c. No., Joir rro.. eto.
3. Work Performed by Owner Type Code Symbol N/A Authorization N/A Expiration Date N/A
4. Identification of System 1-83H Class II Main Steam S stems
5. Ia) Applicable Construction Code AS ME III 19 71 Edition, W'72 Addenda Code Case Ib) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired. Coda Board Replaced, or Stamped Name of Name of Manufacturer Other Year No. Replacement IYes or Component Manufacturer Serial No. Identification Built No) 5 Mech Shock Arrestor Pacific Scientific 5010 N/A SPDBB125H3 1978 REPLACED NO Item 6 Mech Shock Arrestor Pacific Scientific 18577 NIA SPDBB125H3 1981 REPLACEMENT Item 7 Mech Shock Arrestor Pacific Scientific 10918 N/A SPGBB134H3 1979 REPLACED NO ITem 8 Mech Shock Arrester Pacific Scientific 28856 NIA SPGBB134H3 1982 REPLACEMENT YES

1 83H-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required b the Provisions of the ASME Code Section XI

l. Owner Pennsylvania Power 5. Light Co. Oats 05/1 8/95 Two North Ninth St., Allentown, PA 18101 Sheet 3 of
2. Plant Sus uehanna Steam Electric Station Unit Nome Maintenance PO Box 467, Berwick, PA 18603 Addreee Aepeir Crcenireeon p.c. No.. Job No., ero.
3. Work Performed by Owner Type Cade Symbol N/A Authorization N/A Expiration Oats N/A
4. Identification of System 1-83H Class II Main Steam S stems
5. (s) Applicablo Construction Code ASME III 19 71 Ediuon, W'72 Addenda Cods Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 '89 No Add.
8. Identification of Components Repaired or Replaced and Replacement Components Item (s) Susquehanna Work Authorization Cods Repair Form No.

Number Y40280 I95 183-037 Y40280 I95-183-037 Y40280 l95-183<37 Y40280 I95-183-037 Y4o1os l95-183%20 Y40106 l95-183<20 Y40320 I95-183-029 Y40320 I95-183-029

REACTOR PRESS&RE VESSEL EXTERNALEXmwrrNAnOXS

Susquehanna Steam Electric Station Unit I RPV Inservice Examination Eighth Refueling and Inspection Outage Report of Examination Results Owner: Plant:

Pennsylvania Power and I.ight Company Susquehanna Stcam Electric Station Two North Ninth Street Unit 1 Allentown, PA 18601 P. O. Box 467 Berwick, PA 18603 Commercial Service Date: Ratings:

June 8, 1983 3,293 iilwt 1,084.8 ltWWe Manufacturer: National Board Number:

Chicago Bridge and Iron Company 3686 Prepared By: Reviewed By: Ap aveI y' W. F. Miller R. A. Seals .%Stet ass Sr. iVDE Specialist Project Manager ISI Supervisor GEVLE, iVPScSD GEiiE, MUSD PPScL Company Inspection Services Inspection Services Susquehanna Steam Electric Station

REACTOR PRESSURE VESSEL EXTERNAL EXAiVIIINATIONS

SUSQUEHAi tNA STEAiVl ELECTRIC STATION UNIT 1 RP V INSERVICE EXAiMNATON EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAiMNATIONRESULTS TABLE OF CONTENTS SECTION I INTRODUCTION SECTION II SCOPE OF EXAMS WITH WELD LOCATION DRAWINGS SECTION III

SUMMARY

TABLES AND RECORDABLE INDICATIONDATA SECTION IV

SUMMARY

REPORTS

SUSQUEHAi tNA STEAiVT ELECTRIC STATION UMT 1 RPV INSERVICE EcXA~ii ATION EIGHTH REFUELING Ai~ INSPECTION OUTAGE REPORT OF EXAiVGNATIONRESULTS SECTION I INTRODUCTION

SUSQUEHAi~tA STEAiVl ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVQNATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAMINATIONRESULTS SECTION I INTRODUCTION This report contains the results of the inservice examinations performed on the Susquehanna Steam Electric Station Unit 1 Reactor Pressure Vessel. National Board No. 3686, during the Eighth Refueling and Inspection outage. Examinations were performed in the period &om March 25, 1995 through lilay 6, 1995.

The examinations were performed in accordance with the requirements of:

The ASiiE Boiler and Pressure Vessel Code, 1989 Edition, without Addenda.

a. Section V, Nondestructive Examination.
b. Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components-Division 1.
2. United States Code of Federal Regulations, Title 10 Energy.
a. 10CFR21
b. 10CFR50 Apendix B
c. 10CFR50 Subpart 55 United States Nuclear Regulatory Commission Documents
a. Regulatory Guide 1.150 Ultrasonic Testing of Reactor Vessel Welds during Preservice and Inservice Examinations, Revision 1, Alternate method.
b. NUREG 0619 BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking.

American Society for Nondestructive Testing (ASNT) Documents

a. SNT-TC-1A Personnel Qualification and Certification for Nondestructive Testing, 1984 Edition.

Pennsylvania Power and Light Co. ISI Program Documents

a. ISI-T-106/206 Revision 0, "Inservice Inspection Program Plan For The Second Inservice Inspection Interval".
b. ISI-T-108/208 Revision 0, "Class 1, 2, and 3 Components And Component Supports For The Second Inservice Inspection Interval".

Examinations were performed on ASiVEE Section XI Category B-A, B-D, B-G-2 and B-J Components.

Augmented examinations were performed on PP&L Category AUG-2 and AUG-3 Components.

Remote Automated Ultrasonic examinations were performed on accessible portions of RPV shell assembly welds, RPV nozzle to vessel welds, RPV nozzle inside radiused sections, RPV nozzle bore sections, and RPV nozzle to safe end welds. The examinations were perfotmed from the outer surface of the components. The items examined are listed in Section II.

Manual Ultrasonic, Magnetic Particle and Visual (VT-I)examinations were performed on accessible portions of RPV shell assembly welds, RPV nozzle to vessel welds, RPV nozzle to safe end welds and RPV bolting. The examinations were performed &om the outer surface of the components. The items examined are listed in section II.

Original examination data, calibration data, personnel certifications, equipment certifications,.

material certifications, examination procedures, drawings, and evaluations that pertain to these examinations are being retained by PP&L. These documents are controlled by PP&L and are available for review at the Susquehanna site.

A Summary Table for each examination performed, appears in Section IIIof this Report.

Summary Reports containing the Regulatory Guide 1.150 required documentation, the description of examination coverage, the comparison of results with those of previous examinations, and a description of equipment characteristics appear in Section IV of this Report.

SUSQUEHANNA STEAiM ELECTRIC STATION UNIT 1 RPV INSERVICE EXYiVIVfATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EX.&IINATIONRESULTS SECTION II SCOPE OF EXAMS WITH WELD LOCATION DRAWINGS

SUSQUEHAt PfA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAMINATION EIGHTH REFUELING A~1 INSPECTION OUTAGE REPORT OF EXAMINATIONRESULTS SECTION II SCOPE The following items, listed by examination category, were examined during the Susquehanna Unit 1 Eighth Refueling and Inspection outage. The items examined and the examination(s) performed are listed below. The examination results are detailed in Section IIIof the report. The extent of examination coverage is detailed in Sections IIIand IV of this report.

I. ASME SECTION XI Examination Category B-A items examined in accordance with ASME Section XI and USNRC Reg, Guide 1.150 requirements.

AA (RPV Circumferential Weld) Full Length Auto & Manual UT AF (Shell to Flange Weld) 0 to 120 Manual UT BA (RPV Vertical Weld) Partial Auto UT BB (RPV Vertical Weld) Full Length Auto & Manual UT BC (RPV Vertical Weld) Full Length Auto & Manual UT II. ASME SECTION XI Examination Category B-D items examined in accordance with ASME Section and USNRC Reg. Guide 150 requirements.

N1A (Weld & Inside Radius) Full Lenyh Auto & Manual UT N2A (Weld & Inside Radius) Full Lenyh Auto UT N2F (Weld & Inside Radius) Full Length Auto UT N4A (Weld) Partial Auto & Manual UT

N4B(Weld) Full Length Auto & Manual UT N4C (Weld) Full Length Auto & Manual UT N4D (Weld) Full Length Auto & Manual UT N4E (Weld) Full Length Auto UT N4F (Weld) Full Length Auto UT III. ASME Section XI Examination Category B-G-2 items examined in accordance with ASME Section XI requirements.

CRD-10-31-BLT (Bolting) 8 Bolts Visual VT-1 CRD-1043-BLT (Bolting) 8 Bolts Visual VT-1 CRD-14-27-BLT (Bolting) 8 Bolts Visual VT-1 CRD-14-31-BLT (Bolting) 8 Bolts Visual VT-1 CRD-14-35-BLT (Bolting) 8 Bolts Visual VT-1 CRD-1843-BLT (Bolting) 8 Bolts Visual VT-1 CRD-18-59-BLT (Bolting) 8 Bolts Visual VT-1 CRD-26-27-BLT (Bolting) 8 Bolts Visual VT-1 CRD-30-03-BLT (Bolting) 8 Bolts Visual VT-1 CRD-3043-BLT (Bolting) 8 Bolts Visual VT-1 CRD-34-59-BLT (Bolting) 8 Bolts Visual VT-1 CRD-38-15-BLT (Bolting) 8 Bolts Visual VT-1 CRD-38-59-BLT (Bolting) 8 Bolts Visual VT-1 CRD42-11-BLT (Bolting) '8 Bolts Visual VT-1 CRD46-07-BLT (Bolting) 8 Bolts Visual VT-1 CRD-46-19-BLT (Bolting) 8 Bolts Visual VT-1 CRD-50-19-BLT (Bolting) 8 Bolts Visual VT-1 CRD-5047-BLT (Bolting) 8 Bolts Visual VT-1 CRD-54-15-BLT (Bolting) 8 Bolts Visual VT-1 CRD-54-19-BLT (Bolting) 8 Bolts Visual VT-1

IV. ASiVEE Section XI Examination Category B-J items examined in Accordance with ASME Section XI requirements.

N4A (N-SE weld) Full Length Auto & Manual UT, MT N4B (N-SE weld) Full Length Auto & Manual UT, MT N4C (N-SE weld) Full Length Auto & Manual UT, MT N4C (N-SE weld) Full Length Auto & Manual UT, i%IT N4D (N-SE weld) Full Length Auto & ManualUT, MT N4E (N-SE weld) Full Length Auto & Manual UT, MT N4F (N-SE weld) Full Length Auto & Manual UT, MT V. PP&L Examination Category AUG 2 items examined in accordance with USNRC NUREG-0313 requirements. These examinations were performed after MSIP application. The Post-MSIP exams are required over and above the routine exams required by Category C of NUREG-0313.

N1B (N-SE weld) Full Length Auto UT N2B (N-SE weld) Full Lenyh Auto UT N2C (N-SE weld) Full Length Auto UT N2D (N-SE weld) Full Length Auto UT N2E (N-SE weld) Full Length Auto UT N2G (N-SE weld) Full Length Auto UT N2H (N-SE weld) Full Length Auto UT NSA (N-SE weld) Pamal Auto & Manual UT NSA (SE to extension) Full Length Manual UT NSB (N-SE weld) Full Length Manual UT NSB (SE to extension) Full Length Manual UT N8A (N-SE weld) Full Length Manual UT N8A (SE to P-Seal) Full Length Manual UT N8B (N-SE weld) Full Length Manual UT N8B (SE to P-Seal) Full Lenyh Manual UT

VI. PP&L Examination Category AUG 3 items examined in accordance with USNRC NUREG-0619 requirements..

N4A (NIR & Bore) Partial Auto & Manual UT N4A (N-SE weld) Ful! Length Auto & ivfanuaf UT N4B (NIR & Bore) Partial Auto & ManualUT N4B (N-SE weld) Full Length Auto & Manual UT N4C (NIR & Bore) Full Length Auto & ManualUT N4C (N-SE weld) Full Length Auto & ManualUT N4D (NIR & Bore) Partial Auto & ManualUT N4D (N-SE weld) Full Length Auto & iVfanualUT N4E (NIR & Bore) Full Lenyh Auto & ManualUT N4E (N-SE weld) Full Length Auto & ManualUT N4F (NIR & Bore) Full Length Auto & ManualUT N4F (N-SE weld) Full Length Auto & Manual UT

SUSQUEHAi WA STEAiVI ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVIINATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EXAiMNATIONRESULTS SECTION III

SUMMARY

TABLES AND RECORDABLE INDICATIONDATA

SUSQUEHAi~iA STEAiVI ELECTRIC STATION UNIT 1 RPV INSERVICE EXAivZPl'ATION EIGHTH REFUELING AiVD INSPECTION OUTAGE REPORT OF EXAiVIIiATION RESULTS EXAMINATIONCATEGORY 3-A

UNIT I Rpv INSERYICE EXAbinlATION EIGHTH REFUELUIG AND INSPECIION OUTAGE REPORT OP EXASILYATIONRESULTS SECIION 3 CATEGORY 8-A PRESSURE RETAINING WELDS IN REACTOR VESSEL WELD WELD ITEM PROCEDURE TYPE ID iVo.

REACTOR VESSEL B 1.11 GE-ISI-t35 Rev. 2 O'ill C Com posito Auto/iifanual Exam was limited to 99.0%

CIRCUMFEREiVVL 45' of the Code requirement by iVI A 8r. B and NS A 4 B Exam 60' iVRI nozzles .

Viumber Bottom Head to 625019 Shell Course 1 Rev.2 O'iV C NRI ASiVE Xl EXAlVl 45o R NRI 60' B 1.11 GF ISI435 Rcv. 2 45' IVTTA Rev. 2 Exam 45'NT NRI Number 625019 REG.

GUIDE 60' iVRI 1.150 INNER 60'T 25% ofT B 1.11 GE-ISI-t35 Rcv. 2 45o T Rcv. 2 Exam '45'T NRI iVumber 625019 REG.

GUIDE 60o T iVRI 1.150 OUTER 60'T iVRI 75% ofT i'll NO RECORDABLE INDICATIONS C COSIPLETE EXAM R ~ RESTRICTED EXAM

~

T TRAYELDIGINDICATIONPER REG GUIDE I.I50 NT iXONTRAVELINGINDICATIONPER REG GUIDE l.l50

susOUEHAviNA sTEAM ELEcrRIc sTATICN UNIT I RPV UISERVICE EitAMDIATION EIGHTH REFUELLIG AND INSPECIION OUTAGE REPORT OF EXAIiUNATIONRESULTS SECTION CATEGORY B-A PRESSURE RETAINING WELDS IN REACTOR VESSEL

/VELD IVELD 1TEM PROCEDURE EXAM TPPE ID No. TFPE REACTOR VESSEL AF B 130 I iUTA Rev.2 0'VM C NRI Composite Examination, 00 - 120 Combination of these CIRCUI~EREliTIAL $ 50 C examinations yields coverage of 100% of this segment of Exam 60' the weld.

Shell Course 5 I'lumber Io RPV Flange 625023 GE-ISI I23 Rev. 1 O'SS C ASIDE XI E'fAiH AF 130 i IUD Rev. 2 00 - 120' 450 T Exam 454 i fT Number 625023 REG.

GUIDE 600 T 1.150 INNER 60'NT 25% ofT AF 00- 1200 B 130 lid Rev. 2 45' Exam Number 45'NT 625023 REG.

GUIDE 1.150 600 T OUTER 75% ofT 60'fl'RI

~ NO RECORDABLE CIDICATIOIIS C ~ COSIPLETE EviAM R ~ RESTRICIED EXASI TRAvELDIC DIDICATIONPER REC CUIDE I.I50 IIONTRAVKLLICINDICATIONPER REG GUIDE I.ISO

SUSQUKIIANiNASTEAhl ELECTRIC STATIO,'il UiilTI RP Y INSKRYICE EXAhtINATION KtGIrrllREFUELING AND INSPECTION OUTAGE REPORT OF KXASILYATIONRESULTS S ECTION 3 CATEGORY 8-A PRESSURE RETAINING WELDS IN REACTOR VESSEL O'ELD fVELD ITEM PROCEDURE EXrlDf TYPE ID .V0. TYPE REACI'OR VESSEL BA B 1.12 GE-ISI-t35 Rev. 2 04 IVII R iVRI Auto examination was limited to 86.0% of the Code requirement LONGITUDhVAL 45' Viuu by Nozzle N2K Exam 60' iVumber 625020 00 iVM N/A Manual examinations to be ASME XI performed during R Ec 109.

EXAiM 450 iV/A Coverage will then bc 100%.

60O iV/A BA B 1.12 GE-ISI-t35 Rev. 2 450 T

~

Exam 454 NT Number 625020 REG.

GUIDE 60' 1.150 INNER 60'T 25% ofT B 1.12 GF ISI-t35 Rev. 2 45' NRI Exam 45o NT ViRI iVumber 625020 REG.

GUIDE 600 T iVRI 1.150 OUTER 60'T iVRI 75% ofT NRI ~ NO RECORDABLE LIDICATIOiiS C COSIPLETE EXAht R ~ RESTRICTED EXAiht T" TRAVKLUIGINDICATIONPERREG GUIDE I.ISO irr>> NoiVTRAYKLINGLNDICATIONPER REG GUIDE I.I$0

susOUEIIANNA sTEAhl KLKcrnlcsTATtoN UNIT I RP Y INSKRVICE EXASILVATION EIGHTH REPUKLING AND INSPKCI1ON OUTAGE REPORT OP KXAhIUIATIONRES UI TS SKCIION S CATEGORY B-A PRESSURE RETAINING WELDS IN REACTOR VESSEL WELD WELD ITEIV PROCEDURE TYPE ID ivo.

REACI'OR VESSEL BB B 1.12 GF ISI-t35 Rev. 2 04 IVY R iVRI Com posite AutoManual Examination coverage was LOiVGITUDINAL $ 50 R iVIu 100%.

Exam 60' iVRI iVumber 625021 Rev. 2 04 IViH ASi>IE XI EÃAiV 60'B B 1.12 GE-ISI-t35 Rev. 2 45o T iVUT-6 Rev. 2 Exam 45~ VT ViRI iVumber 625021 REG.

GUIDE 60~ T 1.150 PPilER 60'T 25% ofT BB B 1.12 GE-ISI-135 Rev. 2 45' iVRI VIIT-6 Rev. 2 Exam 45 VT iVumber 625021 REG.

GUIDE 600 T 1.150 OUTER 604 VT iVRI 25% o(T NRI ~ NO RECORDABLE INDICATIONS C ~ COSIPLETE KXAihl R ~ RESTRICTED EXAht T~ TRAVELINGINDICATIONPERREG GUIDE I ISO NiT ~ NOiiAYKLINGINDICATIONPER REG GUIDE I ~ ISO

susOUEIIANNA sTEAnt ELEGTRlc sTATIoix UNrr I RPv tNSERYICE ENAMINATION EICIITIIREFUELCIC*ND INSPECTION OUTAGE REPORT OP EXAinnNATIONRESULTS SECflON S CATEGORY B-A PRESSURE RETAINING WELDS IN REACTOR VESSEL IIELD /UELD ITEIll PROCEDURE EXrIM TFPE ID r'Vo. 1YPE REACTOR VESSEL BC B 1.12 GE-ISI I35 Rev. 2 O'M R iVRI Composite Auto(manual Examination coverage was LONGITUDINAI 45' NRI 100%.

Exam 6Q' NRI iVumber 625022 Rev.2 Qo WM ASiME XI EXAM 60'VRI 450 iVRI BC B 1.12 GE-ISI I35 Revi 2 450 T iVRI (VTT4 Rev. 2 Exam 45o NT iVRI ilumber 625022 REG.

GUIDE 6Q' NRI 1.150 INVIER 60'T ViRI 25% ofT BC B 1.12 GF ISI I35 Rev. 2 45o T i lRI (VUT4 Rev. 2 Exam 45'NT ilRI i lumber 625022 REG.

GUIDE 60o T iVRI 1.150 OUTER 60'NT iVRI 75% ofT NRI ~ NO RECORDABLE INDICATIONS C ~ COSIPLETE ENAnt R ~ RESTRIClED Exhnt T- TRAVELINCINDICATIONPER REC CUIDE I.IS((

Nr NOiNTRAVELLNCINDICATIONPER REC GUIDE I.(5((

SVSQUEHA~ii A STEAiVI ELECTRIC STATION UNiIT 1 RPV INSERVlCE EXAi~ATION EIGHTH REFUELING A~i PitSPECTION OUTAGE REPORT OF EXAiVIPifATIONRESULTS EXAiMNATIONCATEGORY B-D

SUSQ UEIIANNASTEASI ELECIIUC STATION UNiIT I RPV LISERVICE EXAPNLIATION EICHTII REFUEUNC AND INSPECIION OUTAGE REPORT OF EXASIINATIONRESULTS 5 CCIIOiI S CATEGORY B-D FULL PENETRATION WELDS OF iNOZZLEI R iVRI IVELD 450 R iVRI Exam 60' iVRI iVumber NUTS Rcv. 2 OOWM R This is a one-sided examination.

625027 454 R iVozzle conllguration limits the 60' accessible portion of the weld to 61.7% of the DVB-2500-7(b) volume.

ASiVIE XI E."IAM Exam NOZZLE INSIDE RADIUS Number B3.100 GE-ISI-ill Rev. 2 ZONE 1 iVRI The inside radius exam was SECTION 625024 100% of the Code requirement ZONE 2A iNRI iVIA B 3.90 GE-ISI-t35 Rev, 2 45' iVRI iVUTA Rev. 2 Exam 45'T iVumber 625027 REG.

GUIDE 60' iNRI 1.150 INNER 604 NT iVRI 25% ofT illA B 3.90 GE-ISI t35 Rev. 2 45' iVRI iVUTQ Rev. 2 Exam 454 NT iVRI iVumber 625027 REG.

GUIDE 604 T iVRI 1.150 OUTER 60'T iVRI 75% ofT NRI iiO RECORDABLE INDICATIONS C ~ COMPLEIE EXASI R ~ RESTRICTED EXASI T ~ TRAVELINGINDICATIONPER REC CUIDE I.iso irf NOiAlLiVELINCINDICATIONPER REG CUIDE I ~ ISO

SUSQUEHANNA STEAM ELECTRICSTATION UNIT I RPY INSERYICE EXASILNATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAhHNATIONRESULTS SECTION S CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS WELD WEI.D ITEIM PROCEDURE EXrhV TYPE ID IVO. TYPE iVOZZLETO VESSEL B 380 GE-ISI I35 Rev. 2 O'M R iVRI WELD 450 R iVRI Exam 600 R Viii iVumber O'M iV/A This is a one-sided examination.

625028 45'V/A 60'V/A iVozzle configuration limits the accessible portion of the weld to 65.6% of the IWB-2500-7(b) volume.

ASME XI EXAM Exam iVOZZLE INSIDE RADIUS iVumber B3.100 GE-ISI-tll Rcv. 2 ZONE I iVRI The inside radius exam was SECITON 625025 100% ol'the Code requirement ZONE 2A Viii iV2A B 3.90 GE-ISI-t35 Rev. 2 50T iVRI Exam 45'NT iVumber 625028 REG.

GUIDE 600 T 1.150 INNER 60'T 25% ol'T B 380 GE-ISI-t35 Rev. 2 454 T Exam 454 NT iVumber 625028 REG.

GUIDE 60' Viii 1.150 OUTER 60'VT 75% ofT NRI >> iNO RECORDABLE DIDICATIOiNS C" COSIPLETE EXAM R>> RESTRICTED FYAM TRAYELING INDICATIONPER REG GUIDE I IS0 NT NONTRAYELINGHIDICATIONPER REG GUIDE I.I$0

SUSQUEHANNA STEAM ELECTRIC STATION 0;IIT I RPV QisKRVICE EXAMINATION KIGIITHREFUELING AND INSPECTION OUTAGE REPORT OF KXASIINATIONRESULTS SKCTIOit S CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS 0 EI.D 0'EI.D ITEM PROCEDURE TFPE ID iVo.

i iOZZLE TO VESSEL iV2F B 3.90 GE-ISI-l35 Rcv. 2 O'M R NRI WELD 450 R IVRI Exam 600 R iVM Number This is a one-sided examinadon.

625029 iVozzle configuration limits the accessible portion of the weld to 65 4 % of the IWB-2500-7(b) volume.

ASiME XI EXAM Exam i lOZZLE INSIDE RADIUS iVumber B3.100 GE-ISI-l11 Rev. 2 ZONE 1 iVIu Thc inside radius exam was SECTION 625026 100% of the Code requirement ZOi lE 2A iVRI N2F B 3.90 GE-ISI t35 Rev. 2 45o T iVRI Exam 45'NT Number 625029 REG.

GUIDE 60' 1.150 INNER 60'T NRI 25% ofT iV2F B 3.90 GE-ISI t35 Rev. 2 45o T NRI Exam 45'NT iVRI ilumber 625029 REG.

GUIDE 60' iVRI 1.150 OUTER 60'VT iVRI 75% ofT NRI ~ NO RECORDABLE INDICATIONS C COMPLETE EXAM R RESTRICTED EXA~I T TRAVELINGINDICATIONPER REG GVIDE I.ISO ONTRAVELINGIiIDICATIONPER REG GVIDE I ISO

SUSQUEHANNA STEAM EI ECIRIC STATION UNIT I RP V INSERVICE EXAMINATION EIGHTH REFUELLNG AND tNSPECTION OUTAGE REPORT OF EXASHNATIO'IRESULTS szcrloN 5 CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS O'ELD 8IELD ITEM PROCEDURE EXAM T1'PE ID ii/o. T1'PE iVOZZLETO VESSEL N4A 8 3.90 GE-ISI-I35 Rev. 2 O'iH R iVRI WELD 45o R iVtu Exam iVUT< Rcv. 2 60o R i lRI iVumber This is a one-sided examination.

625030 Nozzle configuration limits the accessible portion of the weld to 62.0% of the IWB-2500-7(b) volume.

ASiVIE XI EIAiV Exam iVOZZLE INSIDE RADIUS iVumber 83.100 GE-ISI t1 1 Rev. 2 iV/A SECHON iV/A V/A iV4A 8 3.90 GE-ISI I35 Rev. 2 45o T iVTT-6 Rev. 2 Exam., 45'T 4 Spot indications, acceptable.

iVumber 625030 REG.

GUIDE 60' VIRI 1.150 INNER 60'T iVRI 25% ofT N4A 8 3.90 GE-ISI-t35 Rev. 2 45O T iVRI NUTS Rev. 2 Exam 45'T iVumber 625030 REG.

GUIDE 60' iVRI 1.150 OUTER 60'T iVRI 75% ofT NRI ~ NO RECORDABLE INDICATIONS C ~ COSIPLETE EXASI R ~ RESTRICTED EXAM TRAVELL(GINDICATIONPER REC GUIDE I.I50 Nr ~ NONTRAVELINGINDICATION PER REC CUID 8 I.I50

SUSQ UEIIAiliNASTEASI ELECTRIC STATION UNIT I RPV DISERVICE EXASGYATION EIGIITIIREFUELDIG AND QISPECtION OUTAGE REPORT OF EXANINATIONRESULTS SECTION S CATEGORY B-D FULI PEttETRATION WELDS OF NfOZZLES IN VESSELS 0/ELD IPELD ITEM PROCEDURE EX%V REI ARK'S TFPE ID Po. TFPE iVOZZLETO VESSEL N48 8 3.90 GE-ISI t35 Rev. 2 O'WM R iVRI WELD 450 R iVRI Exam ViUTC Rcv. 2 60' NRI iVumber This is a one-sided examination.

625031 iVozzle conBIguration limits the accessible portion of the weld to 65.6% of the IWB-2500-7(b) volume.

ASME XI EXAM Exam NOZZLE INSIDE RADIUS Number 83.100 GF ISI t1 I Rev. 2 ii/A SECTION Vi/A iV/A N48 8 3.90 GF ISI-I35 Rev. 2 45o T iVRI iVUT-6 Rev. 2 Exam i lumber 454 NT iVRI 625031 REG.

GUIDE 1.150 60' INiVER 25% ofT 60'NT iV48 8 3.90 GE-ISI-i35 Rev. 2 450 T NRI i IUD Rev. 2 Exam 454 NT Number 625031 REG.

GUIDE 600 T NRI 1.150 OUTER 60'T 75% ofT NRI >> NO RECORDABLE INDICATIONS C>> COP4PLETE EXA,it R>> RESTRICTED ENAM T>> TRAVELINGINDICATtONPER REG GUIDE I.IS0 NT>> iNONTRAVELING INDICATIOiI PER REG GUIDE I.ISO

SUAVE!IANNASTEAM ELECTRIC STrtTI ON UNIT I RP V INSKRVICE EXAMINATIO'I KIGIITIIREFUELING AND INSPECTION OUTACE REPORTOFKXAML'IATIONRESULTS SKCTIOil 0 CATEGORY B-D FULL PE(IETRATION WELDS OF NOZZLES IN VESSELS WELD WELD ITEM PROCEDURE TFPE ID iYo.

NOZZLE TO VESSEL iV4C B 3.90 GF ISI t35 Rev. 2 04 %i'll R NRI IVELD 450 R NRI Exam 60' iVRI iVumber This is a one-sided examination.

625032 Nonte configuration limits the accessible portion of the weld to 649% oi'he AVB-2500-7(b) volume.

ASiVE XI E'IAi>I Exam i iOZZLE INSIDE RADIUS iVumber B3.100 GF ISl-tl1 Rcv. 2 iV/A SECTION iV/A iV/A N4C B 3.90 GE-ISI-t35 Rev. 2 45O T NRI Exam 45'T Viumber li 625032 REG.

GUIDE 60' 1.150 INNER 60'T 25% ofT N4C B 3.90 GE-ISI t35 Rev. 2 450 T iVM Exam 454 iNT iVumber 625032 REG.

GUIDE 60' iVRI 1.150 OUTER 60'NT iVRI 75% ofT NRI ~ NO RECORDABLE INDICATIONS C ~ COSIPLETE EXAilt R RESTRICTED EXAial T ~ TRAVKLDIGDID ICATION PER REC C VIDE I. ISO itT"NONTRAVKLINGLNDICATIOilPER RKG GUIDE I.I$0

SUSQUEIIANNA STEAM ELECTRIC STATIOaaI UNIT I RP V INSERVICE EXAamNATION EIGHTII REPUELDIG AND INSPECTION OUTAGE REPORT OP EXAbIDIATIONRESULTS sEcrloN 5 CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES W VESSELS WELD WELD ITEM PROCEDURE EXAM 1TPE ID IY0. TFPE iVOZZLETO VESSEL N4D B 3.90 GE-ISI I35 Rev. 2 O'i>I R i iRI WELD 45' iNRI Exam iVUTA Rcv. 2 600 R aVull aVumber This is a one-sided examination.

625033 iVozzle conliguration limits the accessible portion of the weld to 63.0% of the IWB>>2500-7(b) volume.

ASaVE XI EXAiV Exam iVOZZLE INSIDE RADIUS iVumber B3.100 GE-ISI-tl 1 Rcv. 2 iVIA SECTION iV/A iV/A iV4D B 380 GE-ISI 535 Rev. 2 45>> T i LUTE Rev. 2 Exam 45'T iNRI iVum her 625033 REG.

GUIDE 60' 1.150 INNER 60'NT 25% ofT aV4D B 3.90 GE-ISI t35 Rev. 2 45' iVRI aVUTA Rev. 2 Exam 45'NT iVRI aVumber 625033 REG.

GUIDE 600 T VaRI 1.150 OUTER 604 iVT iVRI 75% ofT NRI " iNO RECORDABLE LNDICATIONS C>> COMPLETE ETAM R>> RESTRICTED EXAM T>> TRAVELCaG DID ICATION PER REG GUIDE l.l50 aVP>> NONTRAVELDIGINDICATIONPER REG GUIDE I.I50

SUSQUEHAiNNA STEAM ELECTRIC STATION UNIT I RPV INSERVICE EXAhQNATION EIGHTH REFUELING AND INSPECTIOil OUTAGE REPORT OF EXAhHNATIONRESULTS 5ECIION 5 CATEGORY B-D FULL PENETRATION WELDS OF NOZZLES IN VESSELS IVELD /VELD ITEM PROCEDURE TYPE ID IY0.

i iOZZLE TO VESSEL iV4E B 3.90 GE-ISI-t35 Rcv. 2 Oo WM R iVRI WELD 454 R ViRI Exam 60' IVRI iVumber This is a one-sided examination.

625034 Nonle conliguration limits the accessible portion of the weld to 65.6% of the IWB-2500-7(b) volume.

ASME XI EXAM Exam i NOZZLE INSIDE RADIUS iiumbcr B3.100 GE-ISI-ill Rcv. 2 iV/A SECTION it/A iV/A N4E B 3.90 GE-ISI-l35 Rev. 2 45' Exam 45'T 2 Spot indications, acceptable.

iVumber 625034 REG.

GUIDE 60' NRI 1.150 INNER 60'T 4 Spot indications, acceptable.

25% ofT N4E B 3.90 GE-ISI I35 Rev. 2 45 T Exam 45'T Number 625034 REG.

GUIDE 60' 1.150 OUTER 604 NT iVRI 75% ofT NRI >> NO RECORDABLE !NDICATIONS C>> COMPLETE EXAM R RESTRICTED EXA,'it T>> TRAVEUNG INDICATIONPER REG GUIDE I.!50 iNT>> NOIITRAVELINGINDICATIONPER REG GUIDE I.I50

SUSQUEIIANNA STEAht ELECTRIC STATION UNIT I RPV INSERVICE EXASILYATION EICIITIIREFUELL'IG AND INSPECTION OUTAGE REPORT OF EXASIINATIONRESULTS SECTIOÃ S CATEGORY B-D FULL PEttETRATION FIELDS OF NOZZLES IN VESSELS lVELD 8'ELD ITEM PROCEDURE TFPE ID iVo. REIllAEJKS'VOZZLE TO VESSEL Vi4F B 3.90 GE-ISI t35 Rev. 2 0'VM R iVRI iVELD Exam 45o 60' R iiI NRI Number This is a one-sided examination.

625035 i lozzle contiguration limits the accessible portion of the weld to 65.6% of the DVB-2500-7(b) volume.

ASiME XI EXAiM Exam NOZZLE INSIDE RADIUS Viumber B3.100 GE-ISI-l11 Rev. 2 iV/A SECTION Vi/A iV/A iV4F B 3.90 GE-ISI-t35 Rcv. 2 45O T i lRI Exam 45'T NRI Number 625035 REG.

GUIDE 60' 1.150 INNER 604 NT 25% ofT N4F B 3.90 GE-ISI-t35 Rev. 2 45' NRI

'xam 45O NT iVRI iVum her 625035 REG.

GUIDE 60' iVRI 1.150 OUTER 60'NT ilRI 75% ofT iNRI ~ NO RECORDABLE INDtCATIONS C COSIPLETE ENAht R ~ RESTRICTED EXAht T ~ TRAVELDICINDICATIOitPER REG CUIDE I.ISO i IT >> NONTRAVELLNCINDICATIONPER REG CUIDE I ~ ISO

SUSQUEHANNA STEAiVI ELECTRIC STATION UNIT 1 RPV PfSERVICE EXAiVIINATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAiVKWATIONRESULTS EXAl'dINATIONCATEGORY B-G-2

SUSQUEHANNA STEAM ELECTRIC STATION UNIT I RP V INS ERVICE EXAMINATION EIGHTII REP UELL'IG AND LYSPECIMN OUTAGE REPORT Of ETASILYATIONRESULTS SECTION S CATEGORY B-G-2 PRESSURE RETAINING BOLTING, 2 IiL AÃ3 LESS Pit DIAiVKTER COMPOIVE>VT COMP. ITEM PROCEDURE EXAM TFPE ID I'VO. TYPE VT-I ACCEPTABLE CRD HOUSING CRD , B7.80 Rev. I BOLTS, STUDS, AND 10-31 REPLACED WITH NEW DESIGN iiS EXAMNo.

555005 BOLTS VT-I REJECTABLE CRD HOUSING CRD B 7.80 iiT-I Rcv. I BOLTS, STUDS, AND 10-I3 REPLACED WITH NEW DESIGN ASS EXAMi fo. BOLTS 555006 VT-I REJECTABLE CRD HOUSING CRD B 730 iVTT-I Rev. I BOLTS, STUDS, AND 14-27 REPLACED WITH NEW DESIGiN iiS EXAMNo.

555007 BOLTS VT-I REJ ECI'ABLE CRD HOUSING CRD B 7.80 i Pfl'-I Rev. 1 BOLTS STUDS, AND 14-31 REPLACED WITH iVEW DESIGiN i fUTS EXAiMiNo. BOLTS 555008 VT-I REJECTABLE CRD HOUSING CRD B 7.80 ~i-I Rcv. 1 BOLTS, STUDS, AiVD 1445 REPLACED WITH NEW DESIGN i iUTS EXAiMNo. BOLTS 555009 VT-1 ACCEPTABLE CRD HOUSING CRD B 7.80 iVTT-I Rev. I BOLTS, STUDS, Ai fD 18-13 REPLACED WITH NEW DESIGiN ASS EXAMiNo. BOLTS 555010 VT-I ACCEPTABLE CRD HOUSING CRD B 7.80 i~-I Rcv. I BOLTS, STUDS, AND 18-59 REPLACED WITH iVEW DESIGN i 1UTS EXAilIiNo. BOLTS 555011 VT-I ACCEPTABLE CRD HOUSING CRD B 7.80 i IVT-I Rev. I BOLTS STUDS, AND 26-27 REPLACED WITH NEW DESIGN i IUTS EXAM No. BOLTS 555012 VT-I ACCEPTABLE CRD HOUSING CRD B 7.80 Rev. I BOLTS, STUDS, AND 3043 REPLACED WITH NEW DESIGiN NUTS EXAilINo. BOLTS 555013 VT-I ACCEPTABLE CRD HOUSING CRD B 7.80 iiT-I Rev. I BOLTS, STUDS, AND 30-43 REPLACED WITH iVEW DESIGiV iNUTS EXAiMNo. BOLTS 555014 NRI

SUSQUEIIANNA STEAil ELECTRIC STATION UNIT I RPV INSERVICE ENA>ILTATION EIGBTII REPUELDIG AND &SPECIION OUTAGE REPORT OP E.'fAhUNATIONRESULTS SECTION I CATEGORY B-G-2 PRESSURE RETAICiifGBOLTING, 2 IN. Ai&3 LESS IN DIAiVIETER COMPONEI'YT COMP. ITEM PROCEDURE EXriM REMARKS TYPE ID IYo. TYPE VT-1 REJECI'ABLE CRD HOUSING CRD B 780 iVVT-I Rev. I BOLTS, STUDS) AiVD 34-59 REPLACED WITH iVELV DESIG)V iVUSS EXAiifi lo. BOLTS 555015 VT-I REJ ECTABLE CRD HOUSING CRD B 7.80 i lVT-I Rev. I BOLTS, STUDS, AND 38-15 REPLACED WITH NEW DESIG)V iVUTS EXAMNo. BOLTS 555016 VT-I REJECTABLE I

CRD HOUSING BOLTS, STUDS, iVSS i') CRD 38-59 EXAiH No.

B 7.SO )VTT I Rev.

REPLACED WITHV)EW DESIG)V BOLTS 555011 VT-I REJECTABLE CRD HOUSING CRD B 7.SO iVVT.I Rev. I BOLTS, STUDS, AND 42-11 REPLACED WITH I fEW DESIGVi iVUTS EXAiifi lo. BOLTS 555018 VT-I ACCEPTABLE CRD HOUSPIG CRD B 7.SO )VENT-I Rev. I BOLTS, STUDS, AND 4647 REPLACED WITH iVEW DESIGV) iVUTS EXAiXiVo. BOLTS 555019 VT-I ACCEPTABLE CRD HOUSING CRD B 7.80 iVTT-I Rev. I BOLTS, STUDS, AND 46-19 REPLACED WITH ViEW DESIGN i lUTS EXAIXNo. BOLTS 555020 VT-I ACCEPTABLE CRD HOUSING CRD B 1.SO iVVT-I Rcv. I BOLTS, STUDS, AND 50-19 REPLACED WITH i fEW DESIGN i lUTS EXAi>fiVo. BOLTS 555021 VT-1 ACCEPTABLE CRD HOUSING CRD B 7.SO iVTT I Rcv. I BOLTS, SPUDS) AiVD 50-17 REPLACED WITH iVEW DESIG. l iVUTS EXAi>f No. BOLTS 555022 VT-I REJECTABLE CRD HOUSING CRD B 7.80 iVTT-I Rev. I BOLTS, STUDS, Ai lD 54-15 REPLACED WITH NEW DESIGV iVUTS EXA)if iVo. BOI.TS 555023 VT-I CRD HOUSNiG CRD B 7Jl0 )VS-I Rev. I BOLTS, STUDS, AND 54-19 REPLACED WITH i lEW DESIG) iVUTS EXAiifVio. BOLTS 555024 NRI ~ NO RECORDABLE DIDICATIONS

SUSQUEHAi tNA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiMNATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EK4VIP/ATIONRESULTS EXAMINATIONCATEGORY 3-J

SUSQUEHANNA STEANI ELECTRIC STATION UNIT I RPV IiNSERVICE E',GLiIDIATION EICIITIIREP UELINC AND LNSPECIION OUTAGE REPORT Of ENASILIATIONRESULTS SECTION CATEGORY B-J PRESSURE RETAKING WKLDS IN PIPING JVELD HELD ITEM PROCEDURE TYPE ID iYo.

CIRCUilIFEREiiAL N4A B9.11 N~iD-I Rev. 8 WELD EXAMilo.

i lOZZLE TO 625052 SAFE END CIRC ViMFERENTIAL N4B B9.11 Ni>ITWD-I Rcv. 8 SVR WELD EXAMi lo.

NOZZLE TO 625053 SAFE END CIRCUMFERENTIAL N4C B9.11 NiIITWD-I Rev. S NRI WELD EXAMNo.

NOZZLE TO 625054 SAFE EiiD CIRCViNFEREiVAAL il4D B9.11 Ni>CAVD-I Rcv. 8 i lRI C WELD EXAMiNo.

i lOZZLE TO 625055 SAFE Ei lD CIRCUMFEREiiAL iN4E B9.11 NilITWD-I Rev. 8 SUR iNRI WELD EXAMi lo.

iNOZZLE TO 625056 SAFE END iNRI ~ NO RECORDADLE Ci'DICATIONS

SUSQUEIIANNA STEAM ELECTRIC STATION UNIT I RPV LVSERVICE MASIPNATIOiv EIGIITIIREFUELING AND INSPECIION OUTAGE REPORT OF ENAbILIATIONRESULTS SECTION 3 CATEGORY B-J PRESSURE RETAINING WELDS IN PIP&fG JVELD fPELD ITEM PROCEDURE TYPE ID IVO.

CIRCUilfFERENTIAL iV4F B9.11 iVKAVD-I Rev. 8 SUR iVRI WELD EXAMi lo.

i NOZZLE TO 625057 SAFE EiVD iNRI ~ NO RECORDASLE DIDICATIONS

SUSQUEHANNA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVQNATION EIGHTH REFUELING Ai6) INSPECTION OUTAGE REPORT OF EXAiVGNATIONRESULTS EXAMINATIONCATEGORY AUG-2

SUSQUEIIANNA STEAP4 EI.ECfRIC STAT'ION UNIT I RP Y INSER VICE E.'IASIINATION EICIITIIREFUELUIC AND LNSPECTION OUTAGE REPORT OF ENAPafNATION RESULTS SECTION S CATEGORY AUG-2 AUGMENTED EXAIVGNATIONSPER NUREG-0313

/VELD /VELD 1TEM 'ROCEDURE EYrhM TYPE ID iYo. TYPE i NOZZLE TO SAFE EiVD i iIB-iVOZ- AUG-2 GE-ISI t40 Rev. I VOL iVRI SE Post i%SIP iVon relevant indicahons, such as ID Geometry, Interface, Root, ctc., werc EXAIINo. recorded.

625036 iVOZZLETO SAFE EiVD iV28-iVOZ AUG-2 GE-ISI-t40 Rev. 1 VOL iVRI SE Post MSIP iVon relevant indications, such as ID Geometry, Interface, Root, etc., were EXAM!iVo. recorded.

625037 iiOZZLETO SAFE EiVD iV2C-ViOZ AUG-2 GE-ISI-l40 Rev. 1 VOL iVRI SE Post bISIP iVon relevant indications, such as ID Geometry, Interface, Root, etc., were E fAhI iVo. recorded.

625038 i NOZZLE TO SAFE E~i iV2D-iVOZ- AUG-2 GE-ISI t40 Rev. 1 VOL iVRI SE Post MSIP iVon relevant indications, such as ID Geometry, Interface, Root, etc were EXAiMiVo. recorded.

625039 iVOZZLETO SAFE EiVD iV2E~VOZ AUG-2 GE-ISI-t40 Rev. I VOL iVRI SE Post i%SIP i ion relevant indications, such as ID Geometry, Interlace, Root, etc., were EXAilIiVo. recorded.

625040 iVOZZLETO SAFE EiVD iV2G-iVOZ- AUG-2 GE-ISI-t40 Rev. 1 VOL iVRI SE Post AISIP iVon relevant indications, such as ID Geometry, Interface, Root, etc., werc EXAihI iVo. recorded.

625041 NiRI NiO RELEYAivrENDICATIONS

SUSQLVIIARNASTEAS'I ELECTRIC STATIO,'I IEiIT I RPV UISKRVICE ETASILIATIO!I EIGHTH REf UELLIGAIID INSPECTIOV OUTAGE REPORT Of EEADIUIATIOiI RESULTS SECTIO!I S CATEGORY AVG-2 AVGMEINTEDEXAiVlPlATIONSPER iiVREG-0313 WELD WELD ITEM PROCEDURE EX4Vl TFPE ID IY0. 7YPE iVOZZLETO SAFE END N2H>> lOZ- AUG-2 GF ISI-I40 Rev. I VOL SE Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, etc., were EXAiMVio. recorded.

625042 iVOZZLETO SAFE Ei lD iV2J-iVOZ- AUG-2 GE-ISI-t40 Rev. I VOL SE Post i>ISIP Non relevant indications, such as ID Geometry, Interface, Root, etc werc EXAMNo. recorded.

625043 iVOZZLETO SAFE EiVD iV5A~VOZ- AUG-2 GE-ISI-i40 Rcv. I VOL SE Post i>ISIP Rev. 4 Non relevant Indications, such as ID Geometry, Interface, Root, ctcwere EXAMNo. recorded.

625044 Ezam limited to 939%

SAFE EiVD EXT TO i l5AOE AUG-2 GE-ISI t40 Rev. I VOL SAFE END EXT4E iVUT-I Rev.4 Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, ctc., were EXAMNo. recorded.

625045 iVOZZLETO SAFE EiVD i l58-iVOZ AUG-2 ViTT-I Rev. 4 VOL SE Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, etcwere EXAMNo. recorded.

625046 SAFE EiVD EXTTO Vi584E AUG-2 iVUT-I Rev. 4 VOL SAFE EiVD EX'.

Post iISIP Non relevant indications, such as ID Geometry, Interface, Root, <<tc., were EXAilIVio. recorded.

625047

IRI ~ NO RELEVAiiTBDICATIORS

SUSQUEHANNA STEAbl KLECTRIC STATION UNIT I RPV INSERVICE EXA51LIATION EIGHTII REFUELUIG AND INSPECTION OUTAGE REPORT OP KXASILIATIONRESULTS SKCTION S CATEGORY AVG-2 AVGiVEENTED EXAIVGNATIONSPER t lUREG-0313 JYELD fYELD ITEM PROCEDURE EXAM REMARKS

?TEE ID lvo. TFPE iVOZZLETO SAFE EVD i l8A-iVOZ- AUG-2 i lUT-I Rcv. 4 VOL iVRI SE Post MSIP iVon relevant indications, such as ID Geometry, Interface, Rooh etc., were EXAMiVo. recorded.

625048 SAFE END TO iV8AOE- AUG-2 iVUT-I Rev. 4 VOL iVRI PENT SEAL PENT SEAL Post MSIP iVon relevant Indications, such as ID Geometry, Interface, Root, etc., were fecordcdi EXAMiVo.

625049 iVOZZLETO SAFE END i i8B~VOZ- AUG-2 iVTT-I Rcv. 4 VOL SE Post MSIP iVon relevant indications, such as ID Geometry, Interface, Root, ctc., were EXAMNo. recorded.

625050 SAFE END TO N8M- AUG-2 iVUT-I Rev 4 VOL iVRI PENT SEAL PENT SEAL Post MSIP Non relevant indications, such as ID Geometry, Interface, Root, etc., were recorded.

EXAMiVo.

625051 iNRI NO RELEVANTtNDICATIOiVS

I SUSQUEE54%t fA STEAiVl ELECTRIC STATION UNIT 1 RPV INSERVICE EXAi~ATION EIGHTH REFUELING W fD INSPECTION OUTAGE REPORT OF EXAiVlPifATIONRESULTS EKQVQNATIONCATEGORY AUG-3

SUSQUEHANNA STEASI ELECTRIC STATION UiNIT I RPV LISERVICEEXASIINATION EIGHTH REFUELING AND LNSPECTION OUTAGE REPORT OF EXASILtATIONRESULTS SECTION CATEGORY AUG-3 AUGiiEENTED EXAIVGNATIONSPER NUREG-0619 WELD WELD ITEDf PROCEDURE EXON T1'PE ID IVO. ZYPE NOZZLE INSIDE RADIUS N4A-IR AUG-3 GE-ISI-t1 I Rcv. 2 VOL NRI GE-ISI-t44 Rev. I Examination was limited to 96.2%

EXAMNo. due to the proximity of Nozzie NIIA.

625001 NOZZLE TO SAFE END N4A-VLOZ- AUGH GE-ISI t38 Rcv. I VOL SE NUT-2 Rev. 3 Nion relevant indications, such as ID Geometry, Interface. Root, etcwere EXAMNo. recorded.

625002 Examined 100%

i iOZZLE BORE V14A- AUG'E-ISI III Rev. 2 VOL NRI BORE GE-ISI-i44 Rev. I Examined 100%

EXAMiVo.

625003 NIOZZLE INSIDE RADIUS N4B-IR AUG'E-ISI-ill Rev. I VOL iiRI EXAMNo.

624004 NOZZLE TO SAFE END N48 'iOZ- AU~ GE-ISI-I39 Rev. 0 VOL NRI SE Non relevant indications, such as ID Geometry, Interface, Root, ctc., were EXAMNo. recordedi 624005 NOZZLE BORE iV4B- AUG-3 GE-ISI-III Rev. I VOL NRI BORE GE-ISI444 Rcv. 0 Examination was limited to 98.0%

due to thermocouple pads.

EXAhl Vlo.

624006 NO RECORD*au LNDICATIONS

STEASI ELECTRIC STATIOR BRIT I RPV LISERVICEEXAML'IATION EIGIITII REFUELING AIIDINSPECIIOR OUTAGE REPORT OF EXAIiIINATI0ÃRESUI,TS SECTIOR S CATEGORY AUG-3 AUGMENTED EXAVGNATIONSPER NUREG-0619 IVELD /VELD ITEMS PROCEDURE EXrhM TYPE ID IVO. TYPE NOZZLE INSIDE RADIUS iV4C-IR AUGH GE-ISI-ill Rev. 2 VOL iVRI GE-ISI-i44 Rev. I Examined 100%

EXAiMNo.

625007 iVOZZLETO SAFE EiVD N4C-iiOZ AU~ GE-ISI t38 Rev. 1 VOL i iRI SE NUT-2 Rcv. 3 Non relevant indications, such as ID Geometry, Interface, Root, ctc., were EXAMNo. rccordcde 625008 Examined 100%

i iOZZLE BORE N4C- AUG-3 GF ISI ill Rev. 2 VOL i iRI BORE GF ISI-i44 Rev. 1 Examined 100%

EXAMNo.

625009 i iOZZLE INSIDE RADIUS i i4D-IR AUG'E-ISI-i11 Rev. 2 VOL Examination was limited to 96.2%

EXAMNo. GE-ISI-i44 Rev. 1 due to the proximity of Nozzle NIIB.

625010 iVOZZLETO SAFE EiVD iV4D-ViO? AUGH GE-ISI-i38 Rev. 1 VOL SE i iUT-2 Rev. 3 iVon rclcvant indications, such as ID Geometry, Interface, Root, <<tc., wer>>

EXAi>Ii io. recorded.

625011 Examined 100%

iVOZZLE BORE i 4D- AUGH GE-ISI-tl1 Rev. 1 VOL i iRI BORE GE-ISI t44 Rev. 0 Examination was limited to 96.7%

due to thermocouple pads.

EXAilIVio.

625012 ntu ~ RO RECORDABLE 1NDICATIOBS

'USQUEHANNA STEA,'it ELECTRIC STATION UNIT I RP V INSERVICEEXASIDIA TIP N EIGIITH REFUELING AND INSPECIION OUTAGE REPORT OF EXASIINATIONRESULTS SECTION S CATEGORY AUG-3 AUGMENTED EXAIVGNATIONSPER NUREG-0619 WELD WELD ITEM PROCED URE TFPE ID IY0.

NOZZLE INSIDE RADIUS i i4E-IR AUG-3 GE-ISI-$ 11 Rev. 2 VOL i iRI GE-ISI-i44 Rev. I Examined 100%

EXAMNo.

625013 i iOZZLE TO SAFE ~i N4E~IOZ- AUG-3 GE-ISI t38 Rev. I VOL SE i fUT-2 Rev. 3 Non relevant indications, such as ID Geometry, Interface. Root, etc., were EXAMNo. recorded.

625014 Examined 100%

i iOZZLE BORE iV4E- AUG-3 GE-ISI-t1 I Rev.2 VOL BORE GE-ISI-i44 Rev. I Examined 100%

EXAMNo.

625015 iVOZZLE INSIDE RADIUS iV4F-IR AUG'E-ISI-ill Rev. 2 VOL Examined 100%

EXAMiVo. GE-ISI-I44 Rev. 1 625016 iVOZZLETO SAFE ENiD N4F-iVOZ- AUG'E-ISI-i38 Rev. I VOL SE NUT-2 Rev. 3 i'ion relevant indications, such as ID Geometry, Interface, Root, etcwere EXAiVIi io. recorded.

625017 Examined 100%

i iOZZLE BORE i i4F- AUG-3 GE-ISI-t11 Rev. 1 VOL iVRI BORE GE-ISI t44 Rcv. 0 Examined 100%

EXAMiVo.

625018 iNRI ~ NO RECORDABLE LNDICATIONS

SUSQUEHANNA STEAiVl ELECTRIC STATION UiilT 1 RPV INSERVICE EXAVQNATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EXAiVGNATIONRESULTS SECTION IV

SUMMARY

REPORTS

SUSQUEHAi WA STEAiYl ELECTRIC STATION UNiIT 1 RPV INSERVICE EXAiVONATION EIGHTH REFUELING AND INSPECTION OUTAGE REPORT OF EXAiMNATIONRESULTS

SUMMARY

REPORT "1

Summary Report USNRC REGULATORY GUIDE 1.150 REPORT OF EXAMINATIONRESULTS Number 1: FOR THE SUSQUEHANNA UNIT 1, EIGHTH INSERVICE EXAMINATION.

USNRC Regulatory Guide 1.150, Revision I, Alternate Method requires that ultrasonic examinations performed on reactor pressure vessels be documented in a manner that will allow meaningful comparison of data gathered during successive examinations. This report documents the steps taken by General Electric to assure that the data gathered during the Susquehanna Unit 1 Inservice Ultrasonic Examination meets the intent of Reg. Guide 1.150.

Ultrasonic Examinations during the Susquehanna Unit 1, Eighth Refueling Outage, were performed using both automated and manual examination equipment. This report addresses each section of Reg. Guide 1.150 as it affects both types of examination equipment. Data gathered supporting the conclusions presented in this report is on file at the site.

The results of each examination are reported along with the required evaluations. The examination data is on file at the site.

Procedure GE-ADM-1006, defines the Reg. Guide 1.150 compliance activities performed by General Electric during the Susquehanna Unit I Inservice Examination. This report contains the documentation required by the procedure. The examination was performed in accordance with the requirements of ASiVlE Section XI 1989 Edition, without Addenda; supplemented by GE-ADM-1006.

INSPECTION SYSTEM PERFORMANCE CHECKS The Pre-Exam Performance Checks specified in Paragraph 1.1 of the Reg. Guide Alternate Method were not performed during the Susquehanna Unit I Inservice Examination. General Electric's Quality Assurance requirements do not allow performance checks performed up to six months in advance of an examination to constitute Quality Assurance records for the project. These checks, ifperformed, could not become a part of the records package.

The Field Performance Checks specified in Para~mph 1.2 of the Reg. Guide Alternate Method are performed for both automated and manual ultrasonic examination equipment. The required checks are performed as follows:

Field Performance Checks W

The required RF wave form and &equency amplitude information, for the search units used during the automated examinations, are generated via an FFT transform through the examination system. The system then generates a Data Sheet. The frequency amplitude, band width and associated data appear on the print out. The data displays a digitized RF wave form and all information necessary for re-creating the equipment set-up. A specialized block, designed for obtaining the required data, was used. The reflectors are documented to allow comparisons at a later date. Each transducer was analyzed. RF wave form and frequency analysis information, for each search unit used during the automated exams, is on file at the site. These files contain information gathered before the exams were begun and after they were completed.

The required RF wave form and frequency amplitude information, for the search units used during manual examinations, are also gathered through the FFT transform function of the automated examination system.

The system generated Data Sheet is used. The frequency amplitude, band width and associated data appear on the print out. The data displays a digitized RF wave form and all information necessary for re-creating the equipment set-up. A specialized block, designed for obtaining the required data, was used. The reflectors are documented to allow comparisons at a later date. Each transducer is analyzed for a specific use, and with a specific wedge (shoe) where applicable. RF wave form and frequency analysis information for each search unit used during the manual exams in on file at the site.

Linearity data for both automated and manual examination systems is recorded as required by the applicable examination procedure. The Procedures governing these ultrasonic examinations require documentation of these checks on a calibration data sheet. These calibration data sheets are not an attachment in this report. Linearity data is on file at the site. These files contain all required records.

Beam profile information is obtained for each automated examination package and each manual examination transducer/wedge combination used during ultrasonic examination of RPV welds. The data for automated examination packages is gathered using an automated calibration scanning mechanism. The data for manual examination search units is gathered using manual techniques. The beam profile data is not an attachment to this report. Beam profile data is on file at the site. These files contain information gathered both before the exams were begun and after they were completed CALIBRATION Automated examination system calibrations were performed in accordance with procedure GE-ISI<35 Revision 2 for GERIS 2000 Examination of RPV Assembly Welds. The Initial Calibration of the examination system was performed dynamically using a mechanized calibration scanner that operates in a manner that duplicated the essential variables of the. mechanized examination scanner. This is immediately rechecked in a static mode to cotrelate the calibration simulator. The Initial Recheck (static mode) is then used for subsequent calibrations. The scanner speed set by the operator for the examination scanner was, per procedure, limited to the scanning speed set for the calibration scanner. The direction(s) of scanning during calibration trace (forward) and retrace (backward) are verified during the system calibration. If, for example, a valid calibration is obtained for both trace and retrace modes, examination data may be gathered in both the forward and backward directions. Ifa valid calibration for only one direction was obtained then examination data was gathered only in the direction of the valid calibration. Records for the automated system calibrations are on file at the site.

Calibrations for manual examination systems are performed in accordance with procedure NUT-6, Revision 2, for all Vessel Assembly Welds. This manual examination procedure uses static calibration methods. The signals are maximized during both calibration and examination. Calibrations are verified at scanning speed. Records for manual system calibrations are on file at the site.

There were two nonconformances issued against Geris 2000 calibrations. Both involved exceeding the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> calibration period. In both cases, the data was found to be acceptable. The nonconformance reports appear at the end of this report.

Calibration confirmations, for both automated and manual examination systems, are performed in accordance with the applicable examination procedure. In all cases, the procedural requirements equal or exceed those specified in the ASlvEE Code. There were no electronic simulators or off-site system calibrations used during the Susquehanna Unit 1 Inservice Examination.

The calibration blocks used during the Susquehanna Unit 1 Inservice Examination are furnished by the Owner. These blocks were fabricated in accordance with the requirements of Appendix 1 of ASME Section XI, 1974 Edition, with addenda through Winter 1975. No alternate calibration blocks or new conventional blocks were used during this Inservice Examination. There was an acoustic difference noted between two of the vessel calibration blocks. See report Number 3 for details.

EXAMINATION The scope and extent of the examinations are as specified in the Susquehanna Unit 1 Inservice Inspection Plan. Minor interferences occurred during the examination, due to the RPV and insulation designs. The interferences were analyzed and their effect on the examination documented.

The examinations were performed in accordance with written procedures. The procedures contain requirements for electronic gating and transducer scanning overlap. The procedural requirements are in accordance with Reg. Guide 1.150 requirements.

Internal surface flaw detection capability, for both automated and manual exam systems, is demonstrated by detection of the ASME 2% ID notch during calibration. No alternate reflectors were utilized for this examination. The referenced 1" of material measured perpendicular to the clad/base metal interface was examined. See the Recording and Sizing Section for details.

W The ultrasonic examination techniques developed by General Electric for Inservice Inspections at Susquehanna Unit 1, utilize the ASME Section V, Article 4 specified beaming angles of 0', 45', and 60'.

These beam angles are not based on Susquehanna specific weld preparation details. The ability of these beaming angles to detect unfavorably oriented planar flaws was demonstrated. See the Recording and Sizing Section for details.

The sizing error band, for both automated and manual examination equipment, is estimated below:

Automated Examination Equipment Error Band + 7.6% t ID Notches were consistently oversized. These data are used during indication analysis.

Manual Examination Equipment Error Band + 8.8%t ID notch data was consistently oversized by the combination of beaming angles.

V The estimate of unexamined and not effectively examined volumes, for both automated and manual examinations, are shown below:

I) Volume Affected by near field effects.

Automated Examination .500" beneath the scanning surface Manual Examination .500" beneath the scanning surface

2) Volume Shadowed by Laminar defects.

Automated Examination None determinable, no indications with total loss of back reflection Manual Examination None determinable, no indications with total loss of back reflection

3) Volumes unexamined due to vessel configuration.

Vessel configuration resulted in some unexamined volume for both automated and manual examinations. The "Examination Coverage Report" details the unexamined volumes and their effect on each examination.

4) Unexamined volumes near the cladded ID surface Automated Examination None determinable, artificial flaws at interface are detectable.

Manual Examination None determinable, artificial flaws at interface are detectable.

5) Volumes affected by electronic gating.

Automated Examination None determinable, entire thickness was within the system gates.

Manual Examination No electronic gating was used.

Sketches of Automatic Examination Equipment for use by reviewers, are included with the Coverage Report. No sketches of manual examination equipment are included since the equipment consisted of standard catalogue items needing no such sketches to allow review.

No alternate volumetric examinations were used during the Inservice Examination of Susquehanna Unit 1 Reactor Pressure Vessel Assembly Welds.

Nonconformance Report Project SUSQUEHAi DNA UNIT I Project No. I FRMD SSES I-Ool Reference Documents: (' Q f- W35 +v ~

Description of Nonconformance: (State Cause) NCR Code 043 Cause Code <a Z, Due to mechanical failure the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> calibration period was exceeded by 59 minutes.

Hugo S. %interhalter Initiated By as-'Wts I

ut-'dbate 4I04(95 QC Supervisor Date 10CPR21 Review: ( ) Is (Vf Is Not Reportable Signature:

Proposed Disposition and Technical Justification: (Attach Extra Sheets, Sketches, Etc. as Necessary)

Accept-As-Is El Repair CI Rework Q 'eject C3 Other If Not Mat. Or Items Q The mechanical failure was repaired and the calibration was checked successfully. The elapsed time from cal in to cal out was 12:59.

J~ ~ t'~

Project Manager Date ~

QC Supervisor Date ~ ~

Final D'sition Accept-As-Is & Repair Dispositions, Design Verification Is Provided Per:

Since the calibration was checked successfully the data was determined to be good.

g gg-5's

<<Client

(~ If Required)

Project Manager Preventative Action:

Date Date r~

~rr v *ANI Review QC Supervisor Date Date ~lZ-

  • I v

QC Approval Date

~6'isposition Completed And Nonconformance Report Closed QC Supervisor , ~z~o~W

Nonconformance Report SUSQUEHANiVA UiVIT I Project No. 1 pRMD SSES 1-002 Reference Documents: gQ-jSl- 935'raq. ~

Description of Nonconformance: (State Cause) NCR Code agg Cause Code ~p g Due to delays in being granted access to enter nozzle windows the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> calibration period was exceeded by 66 minutes.

Hugo S. Winterhalter p

Initiated By ate ~9L95 QC Supervisor Date IOCFR21 Review: ( ) Is (+is Not Reportable Signature: ~ljoeS Proposed Disposition and Technical Justification: (Attach Extra Sheets, Sketches, Etc. as Necessary)

Accept-As-Is g Repair Rework CI Reject Other If Not Mat. Or Items O Access was obtained, the transducer package was retrieved and the calibration was checked successfully. The elapsed time from cal in to cal out was 13:06.

j

/

Project Manager Final Disposition Date i 'C Supervisor Date KL ccept-As-I Zc Repair Dispositions, Design Verification Is Provided Per:

Since the calibration was checked successfully, the data was determined to be good and no rescans were necessary.

<<Client If Required)

Dare ~ri+ 'ANi Review D.te+-~~

(~

Project Manager Dare ~~'~ QC Supervisor ~4 ~'ate Preventative Action:

Z~provc. ~p'e ->4b Pla ~ n,~)

QC Approval Date Disposition Completed And Nonconformance Report Closed QC Supervisor Date

SUSQUEHAi~iA STEAM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAMINATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EXAiVIINATIONRESULTS

SUMMARY

REPORT P2

Summary RePort REPORT OF EXAMINATIONCOVERAGE Number 2:

This report details the extent of examination coverage for each item examined, during the Susquehanna Unit I, Eighth Refueling and Inspection Outage. It identifies the areas where transducer access was limited due to RPV configuration, part geometry, insulation configuration, and/or configuration of the search unit.

This report documents the interferences, provides a description of the measures taken to reduce their effect, and provides the percentage of the examination volume/area that was effectively examined.

The following pages list the items examined, the examination technique used, identification of any interference(s), estimates of the volumes examined in accordance with ASME Section XI requirements, and estimates of the volumes not examined in accordance with Section XI requirements. The details of any interference are documented in the Examination Data for the Item.

Susquehanna RF 4 IO 8 GERIS 2000 OD Examination Coverage Report Rev 0 Prepared by: Mark Torok e

Date: g z.t Reviewed by: Wade F. Miller ee~ MP~e Dare: 5/ z 7/9M

Description of the Nozzle Examination Techniques of GKRIS 2000 OD GE Nuclear Energy 175 Curtner Avenue San Jose, California 95125 January, 1995

I. INTRODUCTION This technical description is provided to describe the capability of General Electric's automated RPV inspection system (GERIS 2000) to meet the requirements of Regulatory Guide 1.150 paragraphs 7.b and 7.c and 10 CFR 50-55a(g).

Examination techniques described in this report are those used by General Electric when performing automatic ultrasonic inspections on ASME Code category B-D nozzle to vessel attachment welds. Scanning coverage documented in this report is for nozzle forging (flange type) to vessel seam welds. The ASME Boiler and Pressure Vessel Code referenced in this report is the 1980 Edition Winter 1981 Addenda.

No automated inspection system in use today is capable of effectively examining 100%

of the ASME Code examination volume defined in Section XI - IWB 2500-7(b). This fact has been recognized in that the NRC Regulatory Guide 1.150 requires that volumes that are not examined be defined and documented in the examination report.

II. ASME CODE AND REGULATORY GUIDE 1.150 REQUIREIVIENTS Section 50.55a, "Codes and Standards," of 10 CFR Part 50 requires that Class I components per American Society for Mechanical Engineers Boiler and Pressure Vessel Code (ASME BKPV Code) meet the requirements set forth in Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," of the ASME Code.

Section XI IWB-2500-1 requires that nozzle-to-vessel welds be examined by volumetric inspection techniques. The area to be volumetrically examined for nozzle-to-vessel welds per.

Figure IWB-2500-7(b) is defined as the weld metal plus adjacent base material regions as shown in Fig. 1.

C ~ CODE VGLUME Fig 1 - Nozzle Weld Examination Volume godtechr1

The area to be examined for nozzle-inner radius and bore regions per Figure IWB-2500-7(b) is defined as the inner 1/2 inch of the inner radius and the nozzle bore through to the vessel wall thickness as shown in Fig 2.

C ~ CODE VOLUME Fig 2- Nozzle Inner Radius and Bore Examination Volume Ultrasonic examinations are performed according to Article 4 "Ultrasonic Examination When Dimensioning of Indications is Required" of Section V. Scanning is performed by angle beam and straight beam techniques per paragraphs T-441.5 through T-441.7 wherever such scanning is feasible.

The United States Nuclear Regulatory Commission (NRCj has issued Regulatory Guide 1.150, "Ultrasonic Testing of Reactor Vessel Welds During Preservice and Inservice Examinations", to assure improved pressure vessel inspections. The recommendations of this guide are supplemental to the requirements of Section XI.

For volumes that are inaccessible to the transducer, or volumes shadowed by part geometry that have not been effectively examined, Regulatory Guide 1.150 paragraph 7.b requires that a. best estimate of the affected volume be reported along with the ultrasonic examination results.

godtechr 1

III. AUTOMATED NOZZLE SCANNER Nozzle-to-Vessel Weld and Nozzle Inner Radius Scanner The nozzle device, mounted on a channel track clamped around the nozzle OD cylindrical surface, provides the means of performing a remote ultrasonic examination of the nozzle welds (Fig 3). The nozzle device includes the nozzle tractor, scanner arm and transducer package.

Scanner Transducer Package Tractor Nozzle Weld Centerline Track Front View Side View Fig 3 - Nozzle-to-Vessel Weld Scanner The nozzle tractor consists of a main body with two motor driven magnetic wheels and two hinged end sections, each with one motor driven magnetic wheel. assembly. A pendulum and resolver are mounted on the main body to give the angular position of the nozzle tractor. The reciprocating scanner arm is attached to the nozzle tractor and extends perpendicular to the nozzle track for scanning the nozzle to vessel welds and nozzle inner radius.

The scanner arm consists of a frame, two tandem mounted stepping motors, a worm gear driven resolver, and a ball screw driven plate which holds the ultrasonic transducer package. The scanner arm is held to the vessel wall with two spring loaded guide rods on the inboard end and two magnetic wheels mounted at the outboard end of the scanner arm.

godtechr 1

The transducer package consists of a combination of various transducer wedges ndividually mounted in a frame. The wedges produce beam angles as required by Section V.

To improve coupling and efficiency, a specially designed transducer package assembly is utilized which allows independent transducer suspension and couplant delivery.

Safe-End Mounted Scanner The safe-end mounted scanner (Fig 4I attaches to a channel track clamped around the nozzle safe-end, and provides the means of performing a remote ultrasonic examination of the nozzle inner bore surface. The safe-end mounted scanner is designed for scanning the nozzle bore inner surfaces.

SCANNER AIL% VESSEL I

oooo 0 4

4 4 o TRANSDUCER PACKAGE NOZZLE NOZZLE

'RACTOR SAFE END TRACK FRONT SIDE Fig 4- Safe-End Mounted Scanner The safe-end mounted tractor consists of a main body with two motor-driven magnetic wheels and two hinged-end sections, each with motor-driven magnetic wheel assemblies. A pendulum and resolver are mounted on the main body to give the angular position of the tractor. The reciprocating scanner arm is attached to the tractor and extends perpendicular to the safe-end track for scanning the nozzle-bore region.

godtechr 1

IV. TECHNIQUES FOR NOZZLE-TO-VESSEL WELDS The accessible examination volume of nozzle-to-vessel welds is examined by using three types of scanning packages as described below.

Transverse Scan for parallel oriented reflectors The T-scan (sound beam transverse to the weld axis) transducer package consists of 45 and 60 degree angle beam and a 0 degree straight beam transducer as shown in Fig 5. The 45 and 60 degree angle beam transducers are angulated to produce sound beams that are perpendicular to weld centerline at the vessel inner surface.

Weld Centerl nozzle Nozzle Bore Fig 5 T Scan Examination Package The scan coverages for the T-scan examinations are shown in Fig 6. The examination begins with the T-scan package adjacent the nozzle OD blend radius which is located at Pos 1, the package is scanned radially outward so that the sound beam will pass through-1/2 T (vessel wall thickness) of vessel base metal material (right dashed line). The radial distance needed for the 45 degree transducer is the distance between Pos 2 and Pos 3 for the 60 degree transducer.

One complete revolution of the nozzle scanner, with the T-scan package will scan the accessible examination volume for parallel oriented reflectors using 45 and 60 degree angle beams.

godtechr 1

POS. l POS. E POS. 3 Fig 6 - T-scan Examination Coverage Parallel Scan for transverse oriented reflectors The P-scan (sound beam parallel to the weld axis) transducer packages (P1 and P2) consists of 45 and 60 degree angle beam transducers. The transducers are angulated to produce sound beams that are tangent to the weld centerline at the vessel inner surface.

The P1-scan consists of the 45 and 60 degree angle beam transducers pointed in

.he counter-clockwise direction as shown in Fig 7.

60 CClf lfELD CENTERUNE NOZZLE BORE Fig 7 - P1 Scan Examination Package For the P2 scan, the transducers are rotated to have the sound beams pointed in the clockwise direction as shown in . To compensate for the transducer offset distance from he center of the scanner axis, changes are made to the rotation angles. This compensation results in different rotation angle values for the clockwise and counter-clockwise directions.

godteChrl

SO Cw WELO CENTERLINE NOZZLE BORE Fig 8 - P2 Scan Examination Package Two complete revolutions of the nozzle scanner are made. One revolution with the P1 package and another revolution with the P2 package are performed to scan (from two directions) the accessible examination volume for transverse oriented reflectors.

The scari coverages for the P-scan examinations are shown in Fig 9. The examination begins for the P-scan (P1 and P2) package adjacent the nozzle OD blend radius located at Pos 1. The package is moved radially outward for a distance so the sound beams pass through 1/2 T of vessel base metal material (right dashed line). The radial distance for the 45 degree transducer is Pos 2, and Pos 3 for the 60 degree transducer.

POS. I POS. 8 POS. 3 Fig 9 - P scan examination coverage godtOChr1

Weld and Base Metal Examinations The L-wave scan (0 degree longitudinal) examination is performed with one 0 degree longitudinal beam transducer located in the T-scan package. This single transducer performs dual functions. The first function is the weld metal examination and the second is the base metal examination.

The scan coverages for the L-wave weld and base metal examinations are shown in Fig 10. The examination begins with the L-wave scan package adjacent the nozzle OD blend radius located at Pos 1. The package is moved radially outward so that the sound beam will pass through 1/2 T (vessel wall thickness) of vessel base metal material (right vertical dashed line). The radial distance needed for the 0 degree weld metal examination is Pos 2 and Pos. 3 for the 0 degree base metal exam. The base metal scan examines the volume of base metal material for laminations that would interfere with the angle beam examinations.

POS. I POS. 2 POS. 3 I

I I

Fig 10 - L-wave Weld and Base Metal Coverage One complete revolution of the nozzle scanner, with the T-scan package will scan the accessible examination volume for planar and laminar reflectors using a 0 degree straight beam.

V. EXAMINATIONTECHNIQUES FOR NOZZLE-INNER RADIUS AND BORE.

The nozzle inner radius and bore are divided into five examination zones and are identified as Zones 1, 2A, 2B, 3, 4A, 4B and 5 as shows in Fig 11. Each zone is examined by a separate testing technique. Each examination technique has its own unique transducer array.

godtechr1 10

~ESSEL CLAD NOZZLE SAFE END 4A~3 BB *~ l Fig 11 - Nozzle Inner Radius and Bore Examination Zones To meet the ASME Section XI requirements, examinations are performed on Zones 1 and 2A. On Feedwater nozzles NUREG-0619 requires augmented examinations of Zones 1 through 5.

Zone 1 Examination The nozzle inner radius (Zone 1) is normally examined from the vessel plate with a refracted shear wave that passes through the nozzle-to-vessel weld as shown in Fig 12. The Zone 1 scan consists of two transducers, one, directed in the clockwise direction and the other in the counter-clockwise. This scan is performed with the nozzle scanner as shown previously in Fig 3.

CCW WELD CENYERUNE NOZZLE BORE Fig 12 - Zone 1 Examination Package godtechf1 11

The sound beam is directed to intersect the inner-radius at a favorable angle (normal to an inner-radius flaw) for flaw detection. Sound beam and rotation angles are dependent on the individual nozzle geometry.

The scan coverage for the Zone 1 examination is shown in Fig 13. The examination begins with the Zone 1 package adjacent to the nozzle OD blend radius which is located at Pos 1; the package is scanned radially outward so that the sound beam will pass through inner-radius volume (right dashed line). The radial distance needed for the Zone 1 transducer is the distance Pos. 1 and Pos 2.

One complete revolution of the nozzle scanner, with the Zone 1 package will scan the accessible examination volume of the Zone 1 region for axially-oriented flaws.

POS. I POS. 2 Fig 13 - Zone 1 Examination Coverage In addition, scanning the inner-radius from the nozzle OD blend radius may be preferred on certain nozzle configurations. As is the case for the Zone 1 examination from the vessel plate, the sound beam and rotation angles are dependant on nozzle design.

Zone 2A Examination The Zone 2A area of the nozzle bore is examined with shear waves from the surface where the nozzle OD blend radius merges with the cylindrical surface of the RPV as shown in Fig 14. This scan is performed with the nozzle scanner as previously shown in Fig 3.

godtechr1 12

WELD CENYERUNE NOZZLE BORE Fig 14 - Zone 2A Examination Package The sound beam is designed to intersect the nozzle bore at a favorable angle (normal to a nozzle-bore flaw) for flaw detection. Sound beam and rotation angles are dependent on the individual nozzle geometry.

The scan coverage for the Zone 2A examination is shown in Fig 15. The examination begins with the Zone 2 transducer adjacent the nozzle OD blend radius located at Pos 1. The package is moved radially inward so that the sound beam will pass into the nozzle bore equivalent to a distance of vessel wall thickness (upper horizontally dashed line). The radial distance needed for the Zone 2 examination is the distance between Pos 1 and Pos 2.

POS. 2 POS. 1 Fig 15 - Zone 2A Examination Coverage godtechr1 13

One complete revolution of the nozzle scanner, with the Zone 2A package will scan the accessible examination volume of the Zone 2A region for axially-oriented flaws. Coverage typically includes parts of the Zone 1 and 2B regions.

Zone 2S Examination The Zone 2B area of the nozzle bore is examined with shear waves from the nozzle OD cylinderical surface as shown in Fig 16. The Zone 2B scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise. This scan is performed with the safe end scanner as shown previously in Fig 4.

CCW CW NOZZLE OD SAFE END OD NOZZLE BORE Fig 16 Zone 2B Examination Package The sound beam is designed to intersect the nozzle bore in the Zone 2B region of the nozzle bore. Sound beam and rotation angles are dependent on the individual nozzle geometry.

The scan coverage of the Zone 2B examination is shown in Fig 17..The examination begins with the Zone 2B package adjacent to the nozzle OD blend radius which is located at Pos. 1. The package is scanned axially toward the end of the nozzle OD cylinderical surface which is located at Pos. 2.

godtechr1 14

POS. 2 pos.

Fig 17- Zone 2B Examination Coverage One complete revolution of the safe-end scanner, with the Zone 2B package will scan the accessible examination volume of the Zone 2B region (area not examined with the Zone 2A examination) for axially-oriented flaws.

Zone 3 Examination The Zone 3 area of the nozzle bore is examined with shear waves from the nozzle OD cylinderical surface as shown in Fig 1.8. The Zone 3 scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise. This scan is performed with the safe end scanner as shown previously in Fig 4.

NOZZLE OD NOZZLE SAFE EiVD OD BORE Fig 18 Zone 3 Examination Package godtechr1 IS

The sound beam is designed to intersect the nozzle bore in the Zone 3 region of the nozzle bore. Sound beam and rotation angles are dependent on the individual nozzle geometry.

The scan coverage of the Zone 3 examination is shown in Fig 19. The examination begins with the Zone 3 package adjacent to the nozzle OD blend radius which is located at Pos.

1. The package is scanned axially toward the end of the nozzle OD cylinderical surface which is located at Pos. 2.

POS. 2 POS.

Fig 19 Zone 3 Examination Coverage One complete revolution of the safe-end scanner, with the Zone 3 package will scan the the Zone 3 region for axially-oriented flaws.

Zone 4A Examination The Zone 4A area of the nozzle bore is, examined with shear waves from the nozzle OD cylinderical surface as shown in Fig 20. The Zone 4A scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise. This scan is performed with the safe end scanner as shown previously in Fig 4.

godtechr1 16

CciY C3V YiOZZLE OD iilOZZLE BORE SAFE Ei~D OD Fig 20 Zones 4A and 4B Examination Package The sound beam is designed to intersect the nozzle bore in the Zone 4A region of the nozzle bore. Sound beam and rotation angles are dependent on the individual nozzle geometry.

The scan coverage of the Zone 4A examination is shown in Fig 21. The examination begins with the Zone 4A package adjacent to the nozzle OD cylinderical which is located at Pos. 1. The package is scanned axially to the nozzle-to-safe end blend radius surface which is located at Pos. 2.

POS. 2 POS. i Fig 21 Zone 4A Examination Coverage One complete revolution of the safe-end scanner, with the Zone 4A package will scan the the Zone 4A region for axially-oriented flaws.

godtechr1 17

Zone 4B Examination The Zone 4B area of the nozzle bore is examined with shear waves from the nozzle-to-safe-end blend radius surface with the transducer similar to that as shown in . The Zone 4B scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise. When geometry permits (large blend radius), this scan is performed with the safe end scanner as shown previously in Fig 4, else it is performed manually.

The scan coverage'of the Zone 4B examination is shown in Fig 23. The examination begins with the Zone 4B package adjacent to the nozzle taper which is located at Pos. 1. The package is scanned axially to the nozzle-to-safe end OD surface which is located at Pos. 2.

POS. 2 POS.

Fig 23 Zone 4B Examination Coverage One complete revolution of the safe-end scanner, with the Zone 4B package will scan the the Zone 4B region for axially-oriented flaws.

Zone 5 Examination The Zone 5 area of the nozzle bore is examined with shear waves or RL (depending on safe end material) from the nozzle-to-safe end OD surfaces as shown in Fig 24. The Zone 5 scan consists of two transducers, one directed in the clockwise direction and the other in the counter-clockwise. This scan is performed with the safe end scanner as shown previously in Fig 4. An alternate method is to perform this scan with the SMART 2000 Ultrasonic system.

godtechr 1 18

CC~V ClY NOZZLE OD SAFE END OD NOZZLE BORE Fig 24 Zone 5 Examination Package The scan coverage of the Zone 5 examination is shown in Fig 25. The examination begins with the Zone 5 package adjacent to the nozzle-to-safe end blend radius which is located at Pos. 1. The package is scanned axially to the position on nozzle-to-safe end OD surface which is directly above the point on the thermal sleeve where leakage could occur and is located at Pos. 2.

POS. 2 POS. i Fig 25 Zone 5 Examination Covexage One complete revolution of the safe-end scanner, with the Zone 5 package will scan the the Zone 5 region for axially-oriented flaws.

godteclv1 19

IV. SCANNING COVERAGE The flanged nozzle design when examined from the outside vessel surface does not allow a full volummetric inspection of the volume specified in figure IWB-2500-7(b). The primary limitation is due to the fact that the volume can only be examined from one side and in one direction and is recognized by the ASME Code. Another limitation in scanning the N2H and N2J Recirculation Inlet nozzles was an adjacent N9 Jet Pump Instrument nozzle. The use of a shorter scanning arm was needed to scan this area. The automated transducer (60' scan) could not scan back enough to cover the entire 1/2 T of vessel base material. With this limitation, 87% of the nozzle was scanned with 100% of accessible coverage, while the remaining 13% of the nozzle was scanned with 98% of accessible coverage obtained.

Scan Limitations and Volume of Coverage.

Table 1 summarizes the examined volume from the coverage plots contained in the examination data packages. Areas not examined due to near field effects reflected in the following table (this area has been determined to be the outer 0.5" of examination volume).

% OF SCAN CODE VOLUME OF TOTAL ACCESSIBLE TYPE VOLUME EXAMINED CODE VOLUME VOLUME (SQ. IN) {SQ. IN) EXAMINED EXAMINED 0 WM 65.2 26.4 40 100 45o T 65.2 44.5 68 100 6Q T 65.2 48.4 74 100 60o T 65.2 47.2 72 98 45 P 65.2 33.9 52 100 6Q P 65.2 41.8 64 100 INNER RADIUS 4.0 4.0 100 100

+ - SCANNING VOLUME RESTRICTED BY N9 Table 1 - Cross-sectional examination volume.

Supplemental manual examinations (nozzles)

S upplemental manual examinations to cover the area missed by the automated scanner (60 T scan) between the N2 and N9 nozzles would increase the cross-sectional coverage by 1.2 sq. in. Due to the minimal amount of Code Volume not covered with the 60' scan (2%

of accessible), and the fact that 45 T, 45 P and 60 P scans were performed in this estricted region, no supplemental examination was performed.

godtochr1 20

RF & IO 8 Coverage Report APPE IX A Code Examination Coverage Summary

RF & IO 8 Coverage Repog Summary Component Exam Coverage Composite Code Coverage and Restrictions 625019 AA O'M 100 99% GERIS 2000 Exam restricted at BEEAD-SC1 45 T-scan 99.3 N1A, B and N8A, B. iManual Exam 60'T-scan 96.25 unrestricted. Supplemental Manual 45'P-scan 100 exams performed at N1A, B and 60'P-scan 100 NSA, B.

625023 AF 0' 120M45'T-scan 71 95.4 100% Manual examination coverage of bottom side limited due to flange 60'T-scan 97.2 configuration. Credit taken for 45'P-scan 71 ligament exam brings total credit to100%. (Scheduled Examination from 0'o 120')

625020 BA O'M 100 86% GEMS 2000 Exam restricted at SC1 LONG 45'T-scan 82.5 N2K. No Supplemental manual 60'T-scan 82.5 exams performed this outage. Vpon 45'P-scan 82.5 corn-pletion of supplemental exams 60'P-scan 82.5 during RF 2 IO 9 100% coverage will be achieved.

625021 BB O'M 100 100% GEMS 2000 Exam restricted a SC1 LONG 45'T-scan 100 N2C. Supplemental Manual exams 60'T-scan 100 were performed in this area.

45'P-scan 100 60'P-scan 100 625022 BC O'M 100 100% GERIS 2000 Exam restricted a SC1 LONG 45'T-scan 100 nozzles N1B and N2F. Supplemental 60'T-scan 100 Manual exams performed in these 45'P-scan 100 areas.

60'P-scan 100 625027 N1A O'M 48.2 61.7% GEMS 2000 scanning NOZ-SC1 45'T-scan 80 unrestricted.

60'T-scan 87 45'P-scan 52 60'P-scan 41.2

RF & IO 8 Covenge ReIN~

Summary Component Coverage Composite Code Coverage and Restrictions 625024 N1A I.R. Zone 1 100 100% GERIS 2000 scanning NOZ-IR Zone 2a 100 unrestricted.

625028 N2A O'M 48.6 65.6% GERIS 2000 scanning NOZ-SC1 45'T-scan 79.3 unrestricted.

60'T-scan 86.2 45'P-scan 53.3 60'P-scan 60.6 625025 N2A IR Zone 1 100 100% GERIS 2000 Exam NOZ-IR Zone 2a 100 unrestricted.

625029 N2F O'M 47.6 65.4% GERIS 2000 Scanning NOZ-SC1 45'T-scan 79.3 unrestricted.

60'T-scan 86.2 45'P-scan 53.3 60'P-scan 60.6 625026 N2F IR Zone 1 100 100% GERIS 2000 Exam NOZ-IR Zone 2a 100 unrestricted.

625030 N4A O'M 48.6 62% GERIS 2000 Exam restricted at NOZ-SC3 45'T-scan 73.8 N11A . Supplemental Manual exams 60'T-scan 77 performed in this area, with a L=O to 45'P-scan 52.6 L=+4.5 60'P-scan 58.7 625001 N4A IR Zone 1 92.3 96.2% GERIS 2000 Exam restricted NOZ-SC3 Zone 2a 100 at N11A. Supplemental Manual exams performed in the areas with a D=O to D=+4.5.

625003 N4A-BORE Zone 2b 100 100%GERIS 2000 Exam unrestricted.

FW NOZZLE Zone 3 100 BORE Zone 4a 100 Zone 4b 100 23

RF &, IO 8 Coveni,e Report Summary Component Exam Coverage Composite Code Coverage and Restrictions 625031 N4B O'M 48.4 65.6% GERIS 2000 Scanning NOZ-SC3 45'T-scan 79.3 unrestricted.

60'T-scan 86.2 45'P-scan 53.3 60'P-scan 60.6 625004 N4B IR Zone 1 100 100% GERIS 2000 Exam NOZ-IR Zone 2a 100 unrestricted.

625006 N4B-BORE Zone 2b 100 100% GERIS 2000 Exam FW Zone 3 1'00 unrestricted.

NOZZLE Zone 4a 100 BORE Zone 4b 100 625032 N4C O'M 48.6 64.3% GERIS 2000 T-scan exam at NOZ-SC3 4S'T-scan 79.3 N9A (Azimuth 65'o 95') limited to 60'T-scan 80 a radial distance of 12 inches.

45'P-scan 53.2 60'P-scan 60.6 625007 N4C I.R. Zone 1 100 100% GERIS 2000 Exam NOZ-IR Zone 2a 100 unrestricted.

625009 N4C-BORE Zone 2b 100 100 % GERIS 2000 Exam FW Zone 3 100 unrestricted.

NOZZLE Zone 4a 100 BORE Zone 4b 100 .

625033 N4D O'M 52.6 63% GERIS 2000 Exam restricted at NOZ-SC3 45'T-scan 74 N11B. Supplemental Manual exams 60'T-scan 76.8 performed. in this area, with a 45'P-scan 52.6 L=O to L=+4.5 60'P-scan 58.7 625010 N4D IR Zone 1 92.3 96.2% GERIS 2000 Exam restricted NOZ-IR Zone 2a 100 at N11B. Supplemental Manual exams performed in this area with a D=O to D =+4.5.

RF 4 10 8 Coverage Repog Summary Component ExaIII Coverage Composite Code Coverage and Restrlctlons 625012 N4D-BORE Zone 2b 100 96.7 % GERIS 2000 Scanning FW Zone 3 96 unrestricted.

NOZZLE Zone 4a 90.8 BORE Zone 4b 100 625034 N4E O'M 48.4 GERIS 2000 Scanning unrestricted NOZ-SC3 45'T-scan 79.3 60'T-scan 86.2 45'P-scan 53.3 60'P-scan 60.6 625013 N4E IR Zone 1 100 100 % GERIS 2000 Exam unrestricted NOZ-IR Zone 2a 100 625015 N4E-BORE Zone 2b 100 100 % GERIS 2000 Exam unrestricted Zone 3 100 Zone 4a 100 Zone 4b 100 625035 N4F O'M 48.4 65.6% GERIS 2000 Scanning NOZ-SC3 45'T-scan 79.3 unrestricted.

60'T-scan 86.2 45'P-scan 53.3 60'P-scan 60.6 625016 N4F IR Zone 1 100 100 % GERIS 2000 Exam unrestricted.

NOZ-IR Zone 2a 100 625018 N4F-BORE Zone 2b 100 100 % GERIS 2000 Exam Zone 3 100 unrestricted.

Zone 4a 100 I Zone 4b 100 25

SUSQUEHAi PilA STEAiVl ELECTRIC STATION UMT I RPV INSERVICE E~VQNATION EIGHTH REFUELING Ai&)INSPECTION OUTAGE REPORT OF EKVVIINATIONRESULTS

SUMMARY

REPORT "~

Summary Report COMPARISON OF EXAMINATIONRESULTS Number 3:

The data gathered during the Susquehanna Unit 1 Eighth Refueling and Inspection Outage provides an assessment of RPV integrity. This is a requirement of both ASME Section XI and USNRC Regulatory Guide 1.150. The overall results regarding coverage and detected indications were compared to those from the previous examinations.

There were minor differences in coverage for these welds. This is attributable to equipment modifications during the elapsed time period between the examinations. The differences are not considered to be significant.

There were significant differences in the number of indications detected and in the amplitudes of the detected indications. These were attributable to differences in transducers, exam techniques, and an acoustic difference between Calibration Blocks 1 and 5. Appendix 1 of this report details the actions taken to determine the origin of the differences.

Each recordable indication was analyzed, along with any differences in examination coverage, etc., by a certified Level III individual. These analyses are a part of the data package generated for every item examined. The examination data and required analyses are on file at the site.

Based on the results of these examinations, there is no sign of "Abnormal De~dation" of the Reactor Pressure Vessel. There were no indications that required reporting to the USNRC per Reg. Guide 1.150.

Summary Report APPENDIX 1 Number 3 During the 1989 Inservice Examination of Weld BA, numerous indications were detected by the 0'eld metal scan. The analysis of these indications showed them to be caused by plate se~~gates. PP&L had the EPRI NDE Center confirm the analysis by Ultrasonic and Destructive Testing.

fl Since there was a,commitment to re-inspect Weld BA periodically to confirm that these indications are not growing, Weld BA was inspected during R&IO 8. The previously recorded segregates were not present at the ASiVEE Code sensitivity used to process data. This was a significant difference that was analyzed as follows:

The systems used for these examinations were different. The 1989 examination was performed with a GERIS system. The 1995 examination utilized a GERIS 2000 system. There are operational dift'erences between these systems. The major difference is that the GERIS is an amplitude based system while the GERIS 2000 records all data down to the material noise level.

GERIS data was analyzed based on the sensitivity obtained 6'om the calibration standard. GERIS 2000 data was analyzed by processing with the DAC obtained during calibration being applied to all data. This is a significant difference that should have resulted in the recording of more small laminar indications, rather than less. Because the opposite happened, further analysis was performed.

Since the GERIS 2000 records all data, it was possible to search for the indications by reprocessing the data to extract and display lower amplitude peaks. It was determined that the indications were indeed present in the data, but at amplitudes averaging -16dB (>5X) below the 1989 levels. The GERIS 2000 system was checked and found to be operating properly. It was determined that the cause was not "System Related" so other factors were analyzed. A data review showed that Calibration Block 1 was used for the PSI and the 1995 exams, while Calibration Block 5 was used in 1989.

A comparison of acoustic properties between blocks 1 and 5 was performed. It was determined that the responses I'rom all holes in Block 5 averaged -14dB less than Block 1. When the 1995 data is reprocessed utilizing a reconstructed DAC with values similar to those obtained on Block 5, it compares well with the 1989 results.

The data differences were attributable to a difference between calibration blocks. There does not appear to be a ready explanation for the difference. Both of these blocks were fabricated Rom the same vessel knock-out eliminating the possibility of chemistry differences.

SUSQUEHANNA STEAlM ELECTRIC STATION UNIT 1 RPV INSERVICE EXAiVIINATION EIGHTH REFUELING AiG) INSPECTION OUTAGE REPORT OF EXAMINATIONRESULTS

SUMMARY

REPORT P4

Summary Report EQUIPMEVT VARIABLESTHAT COULD AFFECT DIRECT COMPARISON OF RESULTS Number 4 FROM PREVIOUS OR FUTURE EXAMINATIONS The results of Nondestructive Examinations (NDE) are affected by variations in equipment operating characteristics. These can also affect comparisons of results between a series of examinations. Since there is little published data concerning these variables, GE performed an in house study to quantify them for the GERIS 2000 and Manual examination systems used on GE Contract work. This data forms the basis that enables performance of a comparison of results between examinations performed over a period of time; regardless of equipment type.

There are several broad categories of equipment perfonnance parameters that affect direct comparison of different data sets. The effects of these factors has been estimated by GE, based on both laboratory work and field experience. The factors are:

1. System operational characteristics and the operational differences between equipment types.
2. The tolerances in equipment operational characteristics applied by equipment manufacturers.
3. Differences in transducer characteristics.

The following paragraphs contain a discussion of each item, a comparison of each item as it affects each system, and the effect of each on data correlation.

SI STEM OPE2biTIOPAL CSEriRACTERISTICS The major difference in operational factors for the GERIS 2000 and Manual examination systems used at Susquehanna are due to system design. There are major differences between the data acquisition methods used in Manual systems and those employed by the GERIS 2000 system. These are discussed below:

GENS 2000 Characteristics The Dynamic Range of the system is 85 dB as a minimum.

System bandwidth is considered to be narrow. The system uses tuned Pulsers and Receivers that operate at optimum effeciency in the range of 1.0 liz through 5.0 Mhz.

Search units are selected to provide optimum performance with the system.

Manual System Characteristics This RF/Video circuitry is meant to provide good performance over a broad range of search units.

The bandwidth is considered to be broad. It is meant to operate over a range 6om 1.0 Mhz-10.0 iVZz with adequate performance.

Search units are selected based on adequate performance with the instrument being used. This performance may or may not be optimum.

As shown above these systems are designed to operate differently. Presently neither the ASME or the USNRC consider these differences when addressing data comparisons. With implementation of Appendix VIIIof Section XI, it appears that more data about the effects of these items will become available.

Presently, there is a lack of research data to quantify the effect of these parameters. Research performed at

Pacific Northwest Laboratory (NUREG/CR2264) indicates that tuned instruments offer more consistent results than broader band instruments.

DMVUFACTURER'S TOI ERASES FOR 11VSTRViME)VTS The ultrasonic test instruments used in examination systems, are designed and built to operate within a finite set of tolerances specified by the individual manufacturer. These parameters and tolerances differ between manufacturers but are consistently applied to given models e.g. all Krautkramer USL<8's use the same tolerances but they may or may not apply to USK-7's. Each instrument manufacturer determines what constitutes acceptable performance tolerances for their products, based on the end use(s) they intend for them. It would be unreasonable to expect an instrument that has to provide acceptable performance over a wide range of uses to work as well on a specific use, as one designed for that specific use.

The GERIS 2000 used at Susquehanna, contains a single multiplexed UT system. The effect of manufacturing toletances on examination data is, therefore, minimal. The UT data is produced using pulsers, receivers, logarithmic amplifier, and filtering specifically designed to provide optimum performance as a complete system. Components and parts are replaced with only those having the same characteristics. Each sub-system affects all data equally. Incipient failures are readily detectable and components are replaced before any effect on data can occur.

The manual systems used at Susquehanna contain instruments from several manufacturers. The effect of tolerances is present in the data and should be accounted for in data comparisons.

Experience has shown that different instruments, each operating within the tolerances specified by the manufacturer, can produce widely varying responses from the same reflector. At one operating plant, an indication that was present one year disappeared then reappeared during two subsequent examinations.

The cause was found to be the instruments used, even though each was operating as designed by the manufacturer.

Testing performed by GE shows a spread of+ 5.5dB between instruments produced by a single manufacturer. The test data was generated using the same cable, transducer, wedges, and reflector. The instruments were the only variable. While a single manufacturer's instruments were used in this test, it is reasonable to assume that data gathered using several manufacturer's instruments could show a wider spread. An 11.5 dB spread adds to the difficultyof directly comparing data from a series of examinations on the same component. Instrument differences must be accounted for during any comparison.

TRrilYSDUCER CHrQACTERISTICS Transducers are the most variable component in an examination system. A single transducer can vary over a period of time due to aging, mechanical damage, and wear. Variations between transducers, especially lrom different manufacturers, are due to differences in design, materials, assembly techniques, damping and the active element shape. These cause wide variations in electromechanical efficiency between transducers, leading to differing examination results. These items, alone or in combination, can cause differences in results on the same reflector during successive examinations. They are also responsible for many differences in data when an indication detected with an automated system is verified using a manual system. Of the items above, the ones best understood and documented are transducer shape and electromechanical efficiency.

The GERIS 2000 uses transducers that are eliptical (22 x 32 mm and 18 x 32 mm angle beam) or round (25 mm straight beam). These shapes have a fairly uniform sound field.

More of the useful portion of the beam (-ldB to -6dB) is concentrated near the center. This means that small flaws are likely to be interrogated by the strongest portion of the beam. This increases the likelyhood that small flaws will be recorded during an automated examination.

The manual examination systems use rectangular, I/2" x 1", and round 1" diameter transducers. The sound field with a rectangular transducer is not as uniform as with a round element. The useful portion of the beam is not as concentrated. Small flaws are not as likely to be interrogated with the strongest portion of the beam. Manual exams traditionally record fewer low amplitude flaws than automated exams; for this reason.

The GERIS 2000 uses transducers selected to match system operating characteristics. The electromechanical effiency of these transducers is closely matched. The manufacturer's certification allows selection of search units with similar efficiency.

The transducers used in manual examination systems are catalogue items. The electromechanical effiency of these transducers is not closely matched. A measurement, called Relative Sensitivity (RS), is used to measure efficiency. Relative sensitivity is calculated by measuring the attenuation required to reduce the amplitude of a return signal to a predetermined value; usually 300 millivolts. The higher the required attenuation the greater the efficiency. The RS provides a way to select transducers of similar efficiency, by selecting those within a discreet range of RS attenuation measurements. The RS range for the transducers used with manual systems is based on the search units available. 'Selection of search units for successive examinations of the same indication should account for the possible differences in efficiency.

DISCUSSION The equipment used during an examination can affect the recording of indications during an examination.

The effect of the various components, for the systems used at Susquehanna, are estimated below. These effects have been observed over a number of examinations and the results of these have been used to refine the theoretical data. While these effects exist, they have not been as large as expected based on theoretical estimates.

System characteristics Theoretical effect+ 3dB Observed effect negligible.

Instrument tolerances Theoretical effect unknown Observed effect+ 5.5dB.

Transducer efficiency Theoretical effect+ 6dB Observed effect+ 3dB Transducer shape (small flaws) Theoretical effect+ 6dB Observed effect+ 3dB The data shown above shows a maximum expected difference in performance between systems of 23dB.

This compares well with the observed differences between these systems.

At other Plants, the differences have ranged Rom 4dB through 14.5 dB. This yields an average difference of 9.25 dB. These differences are monitored during each examination. This estimate willbe updated during the next use of the GERIS 2000 at Susquehanna, ifrequired.

Direct comparisons of indications, between automated and manual examination data, is difficultfor the reasons presented above. Ifsuch comparisons become necessary, care should be exercised. Equipment should be selected based on operational characteristics that closely match what was used to detect the flaw originally. Even so, there could be an 11.5 dB difference in results. As long as these differences are considered, such comparisons can be made.

EROSION/CORROSION SCOPE OF ZX~MIN~nOXS

E NUMBER UNIT 1-BRIO -- EROSION/CORROSIOrc EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCO ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP HO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIH WALL ISI ISO ACC 2 LINE GRID EWRHUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE CROSSAROUND-E6 ELBOW X-17 MSEPD 6 TB 10 .625 CROSSAROUND K-594 P43760 CROSSAROUND 42 708 T-21 1 0. 00 8 .417 D.B VT I-EXAM 5N I 7-10EHB K0594-01 X-RIOB RESP95 DBD101 1-E3 ELBOW X-50 FW 10 TB 9 1.375 DBD-101-1 K-563 P43674 RFP FE-1H001A INLET 18 740 T-422 0.00 8 I . 049 0.29 Zl TEMP 7'519-6'WN K0563-01 X-RIOB RESP95 DBD1013-E2 ELBOW X-58 FW 10 TB 0 1.375 DBD-10 1-3 K-564 P43675 RFP 8 EXIT 18 678 T-122 17 79 8 1.049 D.38 8'520-4'WL K0564-0 I X-RIOB RESP95 DBD1015-E 1 90 ELBOW X-61 FW 10 TB 9 1. 375 DBD-101-5 K92 P43649 RFP FE-1HOO IB INLET 18 740 T-422 26.68 8 1. 049 D.38 Z 1-TEMP 8'N20-2'WN K0092-01 X-RIOB RESP95 DBD1015-E2 90 ELBOW X"65 FW 10 TB 9 1.375 080-101-5 K93 P43650 RFP FE- IN001C INLET 18 740 T-422 31.59 8 '1.049 D.39 Z 1-TEMP 5'N20-2'WN K0093-01 X-RIOB RESP95 DBD1041-E 1 TEE 8 X-53 FW 6 TB 11 . 844 DBD-104-1 K-565 P43676 RFP A MIH FLOW 10 670 T-36 12.84 8 .626 D.34 5'N20-7'WJC K0565-O'I X-RIOB RESP95 DBD1042-E 1 TEE 8 X-152 FW 7 TB 12 .844 DBD-104-2 K-566 P43677 RFP 8 MIN FLOW 10 670 T-31 25.23 8 .626 0.72 6'N22-7'WJC K0566-01 X-RIOB. RESP95

NUMBER 2 UNIT 'I-BRIO -- EROSION/CORROSION EXAMS REPORT 2 (SORTEO BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT OTE DBD1043-El TEE 8 X-153 FW 7 TB 12 .844 DBD-104-3 K-567 P43678 RFP C MIN FLOW 10 670 T-31 15.87 8 .626 D.73 3'S21-10'EHE K0567-01 X-RIOB RESP95 OBD1051-E2 ELBOW X-55 FW 11 TB 0 1 . 094 DBD-105-1 K-568 P43679 RFP A LOW LOAD BYPASS 14 732 T-422 0.00 8 .816 D.35 8'521-4'WN K0568-01 X-R IOB RESP95 DLA1021-E3A TEE 0 X-175A FW 26 RB 0 1.031 DLA-'102-1 K95 P43651

'A'FW TO RPV (MAIN) 20 754 R-516 0.00 M .687 D.82 Zl,Z2 TEMP 270DEG AZ 8 22RCL K0095-01 X-RIOB RESP95 DLA 1021-E38 TEE D X-1758 26 0 .688 DLA-102-1 P43651

'A'W TO RPV (BRANCH) 12 FW 754 R-516 RB 26.2 M .459 D.82 K95 Zl, Z2 TEMP 270DEG AZ 8 22RCL K0095-01 X-RI08 RESP95 DLA102'I-ES 90 ELBOW X-177 26 . 688 OLA-102-1

'A'W TO RPV 12 FW 754 RB R-516 41.92 M 0

.459 D.82 K96 P43652 HAND GRID 210DEG AZ 8 22RCL K0096-01 X-RIOB RESP95 DLA1041-E3A TEE 0 X-140A FW 26 RB 0 1.031 DLA-104-1 K99 P43653 RPV INLET 8 20 752 R-516 00. 00 M .687 D.67 Zl-TEMP 90AZ-22RCL K0099-01 X-RIOB RESP95 OLA 104 1-E38 TEE D X-1408 FW 26 RB 0 .688 DLA-104-1 K99 P43653 RPV INLET 8 12 752 R-516 26.2 M .459 Z2-TEMP 90AZ-22RCL . K0099-01 X-RIOB RESP95

P>GE NUMBER 3 UHIT I-BRIO EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE IHSUL MIN WAI.L ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN -

ACTIVITY NO COMMEHTS EXM SCII OUT DTE OLA I 04 'I -E4A REDUCER X-141A FW 26 = RB 0 1. 031 OLA-104-1 K100 P43654 RPV INLET B 20 754 R-516 33.72 M .687 D.67 HAND GRID 90AZ-22RCL K0100-01 X-R I 08 RESP95 DLA I 041-E48 REDUCER X-14 IB FW 26 RB 0 .688 DLA-104-1 K 100 P43654 RPV INLET 8 12 754 R-516 29.69 M .459 D.67 HAND GRID 90AZ-22RCL K0100-01 X-RIOB RESP95 DLA1041-ES 90 ELBOW X-142 FW 26 RB 0 . 688 DLA-104-1 K156 P43659 RPV IHLET 8 12 754 R-516 38.43 M .459 D.67 Z I-TEMP ISODEG AZ-23'RCL K0156 01 X-RIOB RESP9S GAD 1011-El TEE 8 X-I2 MSEPD 9 TB 5 .500 GAD-101-1 K39 P43631 MSEP DRAIN TO 4A 10 707 T-215 88.82 8 .330 D.3 Z I-TEMP 14'N16-5'EL M59 198 K0039-01 X-RIOB RESP95 GAD1011-E2 VALVE X-167 MSEPD 9 TB 5 . 280 GAD- IO I- I K40 P43632 A MSEP DRAIN TO FWH 4A 707 T-215 13.82 B . 186 0.3 EXISTING GRID 4'SI5-8'EL K0040-01 X-RIOB RESP95 GAD1012-E I TEE 8 X-248 MSEPO 10 TB 6 . 500 GAD-101-2 K41 P43633 SIS: X-12, X-249 'IO 708 T-214 34. 11 8 .330 D.3 Z I-TEMP 14'H'19-5'EL K004 'I -0 I X-RI 08 RESP95 GAD 1013" E I TEE 8 X-249 MSEPD 11 TB 6 .500 GAO-101-3 K42 P43634 SIS: X-I2, X-248 10 707 T-212 30.58 8 .330 D.3 ZI-TEMP, Z2-TEMP 14'N24-5'EL K0042-01 X-RIOB RESP95

GE NUMBER 4 UNIT 1-BRIO -- EROSION/CORROSION EXAMS REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF HOM WALL LINE MAP NO. WA NO DETAIL PLAH SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE GAO I 013-E2 VALVE X-169 MSEPD ll TB 5 .280 GAD-101-3 K-43 P43635 A MSEP DRAIN TO FWH 4C 707 T-212 34.04 8 . 186 0.3 14'N24-3'EL K0043-01 X-RIOB RESP95 GBD1021-E 1 90 ELBOW X-192 EXTST 6 TB 0 . 237 GBD-102-1 K-569 P43680 EXTRACTIOH SA DRAIN 701 T-211 24.05 8 . 158 0.75 1 'S19-10'WK K0569-01 X-R I 08 RESP95 GBD1021-E2 90 ELBOW X-155 EXTST 5 TB 5 .23? GBD-102-1 K45 P43636 EXTRACTION 5A DRAIN 708 T-211 72. 15 8 . 158 0.75 Zl-TEMP 6515-4WK M59201 K0045-OI X-RIOB RESP95 GBD1022-El 90 ELBOW X-191 EXTST 7 TB 0 .237 680-102-2 K49 P43640 EXTRACTION 58 DRAIN 701 T-211 56.96 8 . 158 D.74 Zl TEMP O'N2)-6'EHE M59200 K0049-01 X-RIOB RESP95 GBD1022-E2 90 ELBOW X-154 EXTST 6 TB 6 .237 GBD-102-2 K46 P43 637 EXTRACTION 58 DRH 708 T-211 77.21 8 . 158 D.74 Zl TEMP 12N19-4WK M59203 K0046-01 X-RIOB RESP95 GBD1023-E 1 ELBOW X-126 EXTST 7 TB 0 .237 GBD-102-3 K-47 F43638 EXTRACTION JF5 C DRAINS 701 T-211 26.58 8 .'158 D. 1 I 1N23-1'EHE K0047-Ol X-RIOB RESP95 G801023"E2 90 ELBOW X-25 EXTST 7 TB 5 .237 GBD- 102-3 K48 P43639 EXTR 5C DRAIN (20C) 707 T-211 40.51 8 .158 0.11 Zi-TEMP 1'N23-4WK K0048-01 X-RIOB RESP95

E NUMBER 5 UNIT 1-BRIO EROSION/CORROSIUn EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE GBD1031-E1A REDUCER X-791 FWHD 6 TB 0 .322 GBD103-1 K207 P43618 SIS: GBD1032-E2A, GBD'1033-E1A 701 T-211 4.25 8 .215 GBD103- I Zl-TEMP )2'519-0'8JA K0207-OI X-RIOB RESP95 GBD1031-E18 REDUCER X-791 FWHD 6 TB 0 .280 GBD103-1 K207 P43618 SIS: GBD1032-E18, G801033-E18 701 T-211 0.00 8 . 187 GBD'103-1 Z 1-TEMP 12'519-0'8JA K0207-01 X-RIOB RESP95 GBDI032-E1A REDUCER X-793 FWHD 7 TB 0 .322 GBD103-2 K206 F436 19 SIS: G801031-E1A, GBD1033-E'IA T-2'll Z 1 -TEMP 701 12'2 1-1 'J 17.02 8 .215 M59 199 X-RIOB GBD103-2 K0208-01 RESP95 GBD 1032-E I 8 REDUCER X-793 FWHD 7 TB 0 .280 GBD1032-2 K206 - P43619 SIS: GBD 103'I-E18, GBD1033-E18 701 T 211 61.68 8 . 187 GBD103-2 Z -TEMP

'I 12'S21-1'EJ M59 199 K0208-01 X-RIOB RESP95 GBD1042-E 1 ELBOW X-158 FW 10 TB 5 . 300 GBD-104-2 K-570 P4368 1 FWH 58 VENT 707 T-214 3.0 8 .200 D.17 4'S19-16'WM K0570-01 X-RIOB RESP95 GBD 1074-E I ELBOW X-156 CDEM 10 TB 15 .656 GBD- 107-4 K-57 I P43662 DEMIN 8 INLET 16 692 T-123 20.54 8 .437 D.37 5'SI8-4'WN K057 I-O I X-RIOB RESP95 GBD1074-E2 ELBOW X-57 CDEM 10 TB 15 .656 GBD-107-4 K-572 P43683 DEMIN. A INLET 16 692 T-124 31 . 05 8 .437 D.37 4'S17-4'WN K0572-01 X-RIOB RESP95

GE NUMBER 7 UNIT 1-BRIO -- EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL I SI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE GBD1153-E 1 ELBOW X-36 FW 3 TB io .280 GBD-115-3 K-578 P43687 FW S-U AFTER FO-10659C 666 T-40 0.00 8 . 187 D.22 4'N21-10'EG K0578-01 X-RI08 RESP95 GBD1153-E2 ORIFICE X-47 FW 3 TB 10 .280 GBD-115-3 K-579 P43688 F.W. C START-UP FO-10659C 665 T-40 0.00 8 .187 D.22 4'S20-10'EG K0579-OI X-RIOB RESP95 GBDI182-El 90 ELBOW X-150 FW 3 TB 8 .812 GBD-118-2 K63 P43645 F.W. 428 TO 38 20 712 T-2'I 1 57. 19 8 . 541 0.70 Zl-HAND GRID 6'N21-19'EG M59204 K0063-01 X-RI08 RESP95 GBD I 211-E2 ELBOW X-63 FW 11 TB 8 .812 GBD" 'I 21-1 K"580 P43689 RFP C INLET 20 686 T-128 11.43 8 . 541 0.30 1 '23-13 'WM K0580-OI X-RIOB RESP95 GBD1212-E 1 ELB 8 RED X-45 FW 10 TB 10 .812 GBD-121-2 K-58 1 P43690 RFP A INLET 20 686 T-128 36. 53

'19-5 'L .541 D.30 8

I K0581-01 X"RIOB RESP95 GBD1213-E2 ELBOW X-49 FW 9 TB 10 .812 GBD-12'1-3 K-582 P4369 I F.W. 5A EXIT 20 7 I0 T-217 9. 23 8 . 541 D.30 2'N14-4'WM K0582-01 X-RIOB RESP95 GBD1214-E2 ELBOW X-60 FW 10 TB 10 0.812 GBD-12 1-4 K-583 P43692 20 710 T-213 3. 32 8 0.541 1 'S20-'13 lWM K0583-O'I X-RIOB

E NUMBER 6 UNIT 1-BRIO -- EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE GBD1081-E3 VALVE X-219 COND 9 TB 0 .237 GBD-108-1 K-573 F43684 REJECT TO CST 658 T-52 0.00 8 . 157 D. 65 3'N16-5'EK K0573-01 X-RIOB RESP95 GBD108'I-E4A REDUCER X-220A COND 10 TB 0 .500 GBD-108-1 K52 F43641 REJECT TO CST, BOTH SIDES OF VALVE 12 658 T-52 00.00 .333 0.65 Z 1-0BS 10'N17-4'EK K0052-01 X-RIOB RESP95 GBD1081-E48 REDUCER X-2208 COND '10 TB 8 .322 GBD-108-1 K52 P43641 REJECT TO CST BOTH SIDE OF VALVE 658 T-52 00.00 .215 D.65 Z 1-08S

~

10 'N17-4 'K K0052-01 X"R IOB RESP95 GB01091-E3 REDUCER X-137 COND 7 TB 0 F 500 GBD-109-1 K53 F43642 SHORT PATH 14 678 T-113 36.52 8 .333 0.66 HAND GRID 4524-15WK K0053-01 X-RIOB RESP95 GBD1 131-El ORIFICE X-139 FW 7 TB 9 .656 GBD- 113-1 K-5?4 F43685 LONGPATH AFTER HV-10570 16 668 T-36 25. 11 8 .437 D.23 6'N24-17'EHB K0574-OI X-R IOB RESP95 GBD1131-E2 45 ELBOW X-37 FW 7 TB 15 .656 GBD-1 13-1 K54 P43643 LONG PATH AFTER FO-105708 16 718 T-211 35. 15 8 .437 D.23 Z 1-OBS 6'N24-9'WJC K0054-Ol X-RIOB RESP95 GB01131-E3 ORIFICE X-46 FW 7 TB 15 .656 GBD-113-1 K-575 P43686 LONG PATH AFTER FO-10570A 16 718 T-21 I 13. 69 8 .437 0.23 5'N24-14'WK K0575-01 X-RI08 RESP95

AGE NUMBER 8 UNIT 1-BRIO -- EROSION/CORROSION EXAMS REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCO ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE GBD1215-E2 90 EI.BOW X-64 FW ll T-213 TB 8 .812

.54 GBD-'I21-5 K62 P43644 R.W. 5C EXIT 20 710 44.64 8 I D.30 Z 1-TEMP 4'N22-0'8LA K0062-01 X-RIOB RESP95 GBDI252-E1A TEE F X-482A MCPR lo TB 0 0. 237 GBO-125-2 K147 P43655 734 T-422 12.5 C . 157 HAND GRID 1 'N15-2'WL K0147-01 X-RIOB RESP95 GBD1252-E I 8 TEE F X-4828 MCPR 10 TB 0 .250 GBD- I25-2 K147 P43655 734 T-422 47.6 C . 166 HAND GRID 1 '15-2 'WL M59208 K0147-0 1 X-RIOB RESP95 GBD1261-El VALVE X-218 CDEM 12 TB 8 .322 GBO-126-1 K-584 P43693 OEMIN RECYCLE TO CONDENSER HV-11617 668 T-42 57.94 8 .215 D. 11 1

4'S24-8'EN K0584-01 X-RIOB RESP95 GBD 1401-E2 ELBOW X-32 FW 9 TB 5 .300 GBD- 140-1 K-585 P43694 FWH 4A VENT 706 T-215 2.0 8 .200 0-18 6'N15-10'K M59241 K0585-0 I X-RIOB RESP95 GFD1012-E3 ELBOW X-9 EXTST 6 TB 20 .375 GFD-10 I-2 K-586 P43695 EXTR TO FWH 58, C 14 718 T-211 24.8 8 .250 0.2 3'N17-O'WHB K0586-01 X-RIOB RESP95 GFD1012-E4 PIPE X-8 EXTST 6 TB 20 .375 GFD-10'I-2 K-587 P43696 EXTR TO FWH 58, C 14 725 T-2ll 38.4 8 .250 0.2 3'N17-O'WHB K0587-0 I X-RIOB RESP95

Al E NUMBER 9 UNIT I-BRIO -- EROSION/CORROSIOh EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCO ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE G F01013" E2 PIPE X-863 EXTST 9 TB 7 .0375 GFD 101-3 K-595 F43761 16 709 T-215 28.0 8 .250 9 '16-16'L K0595-Ol X-RIOB RESP95 GF01014-E3 PIPE X-864 EXTST 10 TB 6 .375 GFD101-4 K-596 P43762 708 T-214 12. 0 B .250 9 '18-16'L K0596-Ol X RIOB RESP95 GFD1015-E2 PIPE X-865 EXTST 'll TB 5 .375 GFD101-5 K-597 P43763 16 706 T-212 00.00 B .250 9'N24-16'EL K0597-OI X-RIOB RESP95 HAD1021-E2 TEE 8 X-1 FW 6 TB 4 .375 HAD- I02-I-E2 K550 P43739 DRAIN 3A TO 2A 14 707 T-211 14.89 8 .328 D.l 5 '19-0 '8JB K0550-01 X-RIOB RESP95 HBD1061-E2 ORIFICE X-85 TS 6 TB 4 .280 HBD-106-'I K-589 P43697 MSV STEAM LEAKOFF FE-10104 707 T-211 27.65 8 . 186 0.42 2'S17-5'EHB K0589"01 X-RIOB RESP95 HBD1071-El 45 EI.BOW X-847 EXTST 6 TB I6 .375 HBD- 107-1 K-510 P43624 24 719 HPCON 49. 6 .250 HAND GRID 6'S19-6'EHB K0510-01 X-RIOB RESP95

<<601071-E2 PIPE X-846 EXTST 6 TB 18 .375 HBD-107-1 K-511 P43625 24 721 HPCON 44.80 .250 HAND GRID 6'S19-6'EHB K051 1-01 X-RIOB RESP95

GE NUMBER 'IO UNIT 1-BRIO -- EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD1071-E3 90 ELBOW X-825 EXTST 6 TB 15 .375 HBDI07-1 K-512 P43626 24 717 HPCON 90.4 .250 Z1, Z2 TEMP 6'SI9-3'EHB M59234 K0512-0 I X-RIOB RESP95 HBD10710-E1 45 ELBOW X-859 EXTST 3 TB 16 . 375 HBD-107-10 K-539 P43728 24 719 LPCON 49.6 .250 HAND GRID 5'S23-6'WHB K0539-01 X-RIOB HBD 10710-52 PIPE X-858 EXTST 3 TB 18 . 375 HBD-107-10 K-540 P43729 24 721 LPCON 36.8 .250 HAND GRID 5'$23-6'WHB K0540-01 X-RIOB HBD10710-E3 90 ELBOW X-838 EXTST 3 TB 15 . 375 HBD107-10 K-541 P43730 24" 717 LPCON 45.6 .250 3'S23-3'WHB K0541-01 X-RIOB H801071 'I-E1 PIPE X-862 EXTST 7 TB 18 .375 HBD-107-11 K-542 P43731 24 721 LPCON .250 HAND GRID 7'N23-6'EHB K0542-OI X-RIOB HBD107 1 1-52 45 ELBOW X-821 EXTST 7 TB 16 .375 HBD-107-11 K-543 P43732 24 719 LPCON 88.8 .250 HAND GRID 7'N23-6'EHB M59232 K0543-01 X-R IOB RESP95 HB01071 1-E3 90 ELBOW X-840 EXTST 7 TB 15 . 375 HBD107-1 I K-544 P43733 24" 718 LPCON 98.4 .250 7'N23-8'EHB M59233 K0544-01 X-RIOB RESP95

AGE NUMBER 11 UNIT 1-BRIO -- EROSION/CORROSIOn EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT OATEz 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEA5 MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD1071 1-54 90 ELBOW X-841 EXTST 7 TB 10 .375 HBD107-1 I K-545 F43734 2 4 lt 713 LPCON 190.4 .250 4'S23-10'EHB M59225 K0545-0 I X-R IOB RESP95 HBD 10712-E1 PIPE X-856 EXTST 3 TB 18 .375 HBD-107-12 K-546 P43735 24 721 LPCON 30.4 .250 HAND GRID 7'N23-6'WHB K0546-01 X-RIOB HBD10712-E2 45 ELBOW X-857 EXTST 3 TB 16 .375 HBD-107-12 K-547 P43736 24 719 LPCON 167. 2 .250 HAND GRID 7'N23-6'WHB M59223 K0547-01 X-RIOB RESP95 HBD10712-E3 90 ELBOW X-836 EXTST 3 TB 15 .375 HBD107-12 K-548 P43737 24 N 718 LPCON 49.60 .250 7'N23-8'WHB K0548-01 X-RIOB 'ESP95 HBD107 12-E4 90 ELBOW X-837 EXTST 3 TB 10 ~ 375 HBD 107- 12 K-549 P43738 24" 713 LPCON 168.0 .250 4'523-'10'WHB M59226 K0549-0 I X-RIOB RESP95 H801072-EI 45 ELBOW X-845. EXTST 2 TB '16 .375 HBD-107-2 K-5 13 P43702 24 719 HPCON 63.2 .250 HAND GRID 7'S19-6'WHB M59216 K0513-01 X-RIOB RESP95 HBD1072-E2 PIPE X-844 EXTST 2 TB 18 .375 HBD-107-2 K-5 14 P43703 24 721 HPCON 49.6 .250 HAND GRID 7'S19-6'WHB K0514-01 X-RIOB RESP95

GE NUMBER 12 UNIT I-BRIO -- EROSION/CORROSIOn EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD1072-E3 90 ELBOW X-824 EXTST 2 TB 15 .375 HBOI07-2 K"5 15 P43704 24" 717 HPCON 118.4 .250 6 '19-3 'WHB M59213 K0515-01 X-RIOB RESP95 HBD1073-El PIPE X-848 EXTST 6 TB 18 .375 HBD-'107-3 K-516 P43705 24 721 HPCON 47.2 .250 HAND GRID 5'N19-6'EHB K0516-01 X-RIOB RESP95 HBD1073-E2 45 ELBOW X-849 EXTST 6 TB 16 .375 HBD-107-3 K-517 P43706 24 719 HPCON 23. 2 .250 HAND GRID 5'N19-6'EHB K0517-01 X-RIOB RESP95 HBDI073-E3 90 ELBOW X-826 24'XTST 7 17 6

HPCON TB 98.4

'15 .375

.250 HBD107-3 K-5'IB P43707 5'N19-8'EHB M59218 K0518-01 X-RI08 RESP95 HBD1073-E4 90 ELBOW X-827 24'XTST 712 6

HPCON TB 100.0 10 .375

.250 HBO107-3 K-5'19 P43708 6'519-10'EHB M59214 K0519-01 X-RI08 RESP95 HBD1074-El PIPE X-842 EXTST 2 TB 18 .375 HBD- 107-4 K-520 F43709 24 721 HPCON 48.8 .250 TEMP 5'N19-6'WHB K0520-01 X-RIOB RESP95 HBD1074-E2 45 ELBOW X-843 EXTST 2 TB 16 .375 HBO-107-4 K-521 P43710 24 719 HPCON 29.6 . 250 Zl, Z2 TEMP 5'N19-6'WHB K0521-01 X-RIOB RESP95

PAfiE NUMBER 13 UNIT 1-BRIO -- EROSION/CORROSIOh EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE fLEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HB01074-E3 90 ELBOW X-822 EXTST 2 TB 15 .375 HBD107-4 K-522 P43?11 24 II 717 HPCON 77. 6 .250 5'NI9-8'WHB M59220 K0522-01 X-RIQB RESP95 HBD1074-E4 90 ELBOW X-823 EXTST 2 TB 10 .375 HB0107-4 K-523 P43712 24" 7 12 HP CON 102. 4 .250 6' 19-10WHB M59215 K0523-01 X-RIOB RESP95 H801075-E1 45 ELBOW X-829 EXTST 7 TB 16 .375 HBD-107-5 K224 P43622 24 7'19 IPCON '104.8 .250 HAND GRID 6'S2 1-6'EHB M59230 K0224-01 X-RIOB RESP95 HBD1075-E2 X-854 EXTST 7 TB IB .375 HBD-107-5 K-524 P43713 24 721 IPCON 41. 6 .250 HAND GRID 6'S2'1-6'EHB K0524-01 X-RIOB RESP95 HBD1075-E3 90 ELBOW X-832 24'XTST 717 7

IPCON TB 57.6 15 . 375

.250 HBD107-5 K-525 P43714 4'S21-3'EHB M59227 K0525-01 X-RIOB RESP95 HBD1076-E1 45 ELBOW X-853 EXTST 3 TB 16 . 375 HBD-107-6 K-526 P43715 24 719 IPCON 73.6 .250 HAND GRID 6'S21-6'WHB M59229 K0526-01 X-R IOB RESP95 HBD1076-E2 PIPE X-852 EXTST 3 TB IB .375 HBD-107-6 K-527 F43716 24 721 IPCON 31. 2 .250 HAND GRID 6'521-6'WHB K0527-01 X-RI08 RESP95

PARE NUMBER 14 UNIT 1-BRIO EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD1076-E3 90 ELBOW X-831 EXTST 3 TB .375 HBD107-6 K-528 P43717 24" 717 IPCON 70.40 .250 4'S21-3'WHB M59221 K0528-01 X-RIOB RESP95 HBD 1077-E1 PIPE X-833 EXTST 7 TB 18 .375 HBD-107-7 K225 P43623 HAND GRID 24 721 IPCON 48.0 .250 6'N21-6'EHB K0225-01

- X-RIOB RESP95 HBD1077-E2 45 ELBOW X-855 EXTST 7 '16 .375 TB HBD107-7 K-529 F437'IB HAND GRID 24 719 IPCON 49.6 .250 6'N21-6'EHB K0529-01 X-RIOB RESP95 HBD'1077-E3 90 ELBOW X-834 24'XTST 718 7

IPCON TB 69.6 15 .375

.250 HBD107-7 K-530 P43719 6'N21-8'EHB M59231 K0530-01 X-RIOB RESP95 HBDI077-E4 90 ELBOW X-835 EXTST 7 TB 10 .375 HBD107-7 K-53 24" 1 P43720 204.8 5 '2 1-10 'HB 713 IPCON .250 M59228 K053'1-01 X-RIOB RESP95 HBD1078-E1 PIPE X-850 EXTST 3 TB 18 .375 HBD107-8 K-532 P43721 24 721 IPCON 40.8 .250 HAND GRID 6'N2 1-6'WHB K0532-OI X-RIOB RESP95 H801078-E2 45 ELBOW X-851 EXTST 3 TB 16 .375 HBD-107-8 K-533

. F43722 24 719 IPCON 57. 6 .250 HAND GRID 6'N21-6'WHB M59219 K0533-01 X-R I 08 RESP95

iE NUMBER 15 UNIT 1-BRIO EROSION/CORROSIOtc FXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT IO DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD1078-E3 90 ELBOW X-828 EXTST 3 TB 15 .375 HBD 107-8 K-534 P43723 24 ol 717 47.2 .250 6 '2 1-8 'HB IPCON K0534"0 I X-R IOB RESP95 HBD1078-E4 90 ELBOW X-830 24'XTST 7 12 3

IPCON TB 112.8

'10 .375

.250 HBD107-8 K-535 P43724 5'S21-10'WHB M59235 K0535-01 X-RIOB RESP95 HBD1079-E1 45 ELBOW X-861 EXTST 7 TB 16 ~ 375 HBD-107-9 K-536 P43725 24 719 LPCON 120. 0 .250 HAND GRID 5'S23-6'EHB M59224 K0536-01 X-R IOB RESP95 HBD1079-E2 PIPE X-860 EXTST 7 TB 18 .375 HBD-107-9 K-537 P43726 24 721 LPCON 40.8 .250 HAND GRID 5'S23-6'EHB K0537-01 X-RIOB RESP95 HBD1079-E3 90 ELBOW X-839 EXTST 7 TB 15 .375 HBD 107-9 K-538 P43727 24 M 717 LPCON 48.8 .250 3'S23-3'EHB K0538-01 X"RIOB RESP95 HBD 1 081-E1 TEE A X-15 EXTST 2 TB 12 .375 HF D- 1 08- 'I K64 P43646 EXTR TO FWH 4C 24 717 HPCON 00.00 .250 D.6 3N19-5 ' "WHB K0064-01 X-RIOB RESP95 HBD108 I-E2 45 ELBOW X-256 EXTST 2 TB 15 .375 HBD-108- I K65 P43647 SIS: X-257,260,261,264,265 16 720 HPCON 00.00 .250 D.6 3'5 19-5'WHB K0065-01 X-RIOB RESP95

iE NUMBER 16 UNIT 1-BRIO -- EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WAI.L LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD 109 1-E 10 45 ELBOW X-709 EXTST 6 TB 10 0.375 HBD 109-1 P43628 26 712 T-211 0.0 8 0.250 HBD 109-1 4'516-5'WJC K0006-O'I X-RIOB RESP95 HBD1093-EB 90 ELBOW X-728 EXTST 7 TB 10 0.375 HBD109-3 K32 F43629 26 712 T-211 3.2 8 0.250 HBD109-3 Z1, Z3 TEMP 4521-1 'I WK K0032-Oi X-RIOB RESP95 HBDI093-E9 90 ELBOW X"729 EXTST 7 TB 10 0.375 HBD109-3 K33 P43630 26 712 T-211 41. 60 8 0.250 HBD 109-3 ZI-TEMP 9N24-1 1WK K0033-01 X-RIOB RESP95 HBD1094-E1 ELBOW 90 X-735 EXTST 6 TB 12 0.375 HBD 109-4 K556 P43667 20 714 T-211 21. 6 8 0. 250 HBD 109-4 2'N 19-10'WK K0556-01 X-RIOB RESP95 HBD1 141-E2 ELBOW X-34 FW 2 TB 0 .216 HBD-114-1 K-590 P43698 FWH 2A VENT 704 T-211 22.22 8 . 144 - D.20 7'5 18-3'EGB K0590-01 X-RIOB RESP95 HBD1212-E4A TEE 8 COND. PUMP A INLET (MAIN)

X-56A 48 COND 649 8

T-31 TB 6.4 0

'375 .250 HBD-121-2 D.36 K-591 P43699 2'N25-5'WK K0591-01 X-RIOB RESP95 HBD1212-E48 TEE D X-568 COND 8 TB 0 .375 HBD-12 'I -2 K-591 P43699 COND. PUMP A INLET (BRANCH) 30 649 T-31 7.20 .250 D.36 2'N25-5'WK K0591-01 X-RIOB RESP95

AGE NUMBER 17 UNIT 1-BRIO -- EROSION/CORROSION EXAMS REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE HBD1542-E3 90 ELBOW X-166 TS 6 TB 22 .237 HBD-154-2 K89 P43648 HP TURB INNER GLAND LKOFF 726 T-211 31. 25 8 . 157 D.79 Z 1 "TEMP 4'5"N18-O'HB K0089-01 X-RIOB RESP95 HBD'1662-EI ELBOW X-159 TS 9 TB 8 .322 HBD-166-2 K-592 F43700 EXTR.STEAM TO SSE 738 T-416 11. 21 8 . 215 D.76 8 '16-1 I 'WM K0592-O'I X-RIOB RESP95 HBD1681-E3 45 ELBOW X-816 SSE 2 TB 15 .237 HBD168-1 K211 P43620 695 T-1'13 24.05 8 . 157 HBD 168- I Z 1-TEMP 6'S17-3'WHB K0211-01 X-RIOB RESP95 SPEBD1112-El 90 ELBOW X-186 RFPT 7 TB 12 .358 SP-EBD- 111-2 K-598 P43764 RFPT 8 HP BEFORE SEAT DRAIN 670 T-36 '18.48 8 .239 D.86 6'N21-12'WK K0598-OI X-RIOB RESP95 SPEBD1112-E2 ORIFICE X-'185 RFPT 7 TB 12 .358 SP-EBD-1 1 1-2 K-599 P43765 RFPT 8 HP BEFORE SEAT DRAIN FO-127128 670 T-36 21 ~ 84 8 .239 D.86 6'N21-11 'WK K0599-01 X-RIOB RESP95 SPEBD11'15-EI 90 ELBOW X-184 RFPT 6 TB 12 .358 SP-EBD-111-5 K-600 P43766 RFPT A HP BEFORE SEAT DRAIN 670 T-36 12.6 8 .239 D.85 AMERTAP IMPACT 6'S18-12'WK K0600-01 X-R I 08 RESP95 SPEBD I 143-E 1 90 ELBOW X-'133 RCIC 25 WING 4 .358 SP-EBD-114-3 K215 P43621 RCIC STEAM LINE DRAIN 723 R-4 11 36.66 8 .238 D.62 EXISTING GRID 10'S23.5-10WP K0215-01 X-RIOB RESP95

llfiE NUMBER 18 UNIT 1-BRIO -- EROSION/CORROSIOh EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPGAD1382"E2 ORIFICE X-92 BPS 2 TB 9 .250 SP-GAD-138-2 BYPASS STEAM LINE DRN FO-'IOIOB K157 P43660 689 T- I 13 16.86 8 . 167 0.45 Z I-TEMP 15'N19-13'EG K0 157-01 X-RIOB RESP95 SPGAD1443-E12 ELBOW X-124 TURB 2 TB 0 .344 SP-GAD- 144-3 K-601 MAIN STEAM AFTER CV DRAINS P43767 678 T-128 26.95 8 .229 D. 57 4'NIB-4'EHB K0601-01 X-RIOB RESP95 SPGBD1041-5 I 90 ELBOW X-182 FW 11 TB 0 .300 SPGBD-104-1 K-602 FWH 5C VENT P43768 703 T-212 20.00 8 .200 D.84 5'N23-2'ELA K0602-01 X-RIOB RESP95 SPGBD1042-El 90 BEND X-181 FW 9 TB 0 .344 SPGBD-104-2 K 158 P43 661 FWH SA VENT 704 T-215 49. 56 HAND GRID 8 .229 0.83 4'N15-12'WM K0158-01 X-RIOB RESP95 SPGBD1254-El VALVE X-206 MCPR 9 TB 0 .250 SP-GBD-125-4 AUX SEAL STEAM SUPPLY DRAIN K170 P43598 733 T-416 73.80 8 . 166 D.99 HAND GRID 2'N15-I 'WL M59207 K0170-01 INCLUDE BEND W/VALVE X-RIOB RESP95 SPGBD1281-E I ORIFICE X-674 FW 9 TB 8 .344 SP-GBD-128-1 K-160 SIS: X-675, 676 P43662 710 T-215 13. 91 8 . 229 D. 194 2'515-8'WM K0160-01 X-RI08 RESP95 SPGBD I 282-E I SIS: X-674, 675 ORIFICE X-676 FW ll T-212 TB 0 .344 SP-GBD-128-2 K-603 P43769 706 27.82 8 .229 D. 196 9'N24-6'WM K0603-0 I X-RIOB RESP95

AGE NUMBER 19 UNIT 1-BRIO -- EROSION/CORRO N EXAMS REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID OESCR I PTI ON REPLCD IO SYSTEM AREA BUILD SCAFF NOM WALl LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPGBD1287-E1 ORIFICE X-675 FW IO TB 0 .344 SP-GBD-128-7 K-604 P43770 SIS: X-674, 676 706 T-214 19. 13 8 .229 D. 195 9'S18"6'WM K0604-01 X-RIOB RESP95 SPGBD13318-E1 ELBOW X-132 RFPT 10 TB 0 .250 SPGBD-133-18 K-181 P43603 RFPT A LP BELOW SEAT DRAINS 682 T-116 31. 32 8 . 167 D. 6'I 7'S19-10'EK K0181-01 X-RIOB RESP95 SPG8013319-E1 90 ELBOW X-2 12 RFPT 10 TB 0 . 219 SPGBD-133-19 K182 P43604 A RFPT CHEST DRAIN .75 681 T-116 31.08 8 . 145 D. 105 HAND GRID 2'S19"9'EK K0182-01 X-RIOB RESP95 SPGB013321-Ei 90 ELBOW X-214 RFPT 1 'I TB 0 . 219 SPGBD-133-21 K'183 P43605 C RFPT CHEST DRAIN .75 68'I T-114 31.08 8 . 145 D. 107 HAND GRID 1'N23-8'EK KO 'I 83-0 I X-RIOB RESP95 SPGBD13322-E1 90 ELBOW X-213 RFPT 11 TB 0 . 219 SPGBD-133-22 K184 P43606 B RFPT CHEST DRAIN .75 681 T-115 9.45 8 . 145 D. 106 HAND GRID O'S21-9'EK K0184-01 X-R I 08 RESP95 SPGBDI339-E1 90ELBOW X-2 10 RFPT 11 TB 0 .250 SP-GBD-133-9 K-605 P43771 8 RFPT LP BEFORE SEAT DRAIN 682 T-115 26.5 8 . 167 D. 103 6'S21-10'EK K0605-01 X-RIOB RESP95 SPGBD1441-E1 ELBOW X-121 TURB 6 TB 12 . 344 SP-GBD-144-1 K-606 P43772 MSV BEFORE SEAT DRAINS 671 T-36 27.82 8 .229 D.56 9'N19-O'WJC K0606-01 X-RIOB RESP95

GE NUMBER 20 UNIT 1-BRIO -- EROSION/CORROSIOa EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPGBO1442-E4 VALVE X-120 TURB 6 TB 4 .250 SP-GBD-144-2 K607 P43773 MSV A BEFORE SEAT DR HV-10101A-D 706 T-21) 26.5 8 . 167, 0.56 12'N)7-17'WK K0607-OI X-R IOB RESP95 SPGBD1521-E1 ELBOW X-130 RFPT 7 TB '10 .250 SP-GBD-152-1 K-608 P43774 MAIN STEAM TO RFPT DRAINS 670 T-36 31.32 8 .)67 0.28 7'N23-7'EJ K0608-01 X-RIOB RESP95 SPGBD )521-E3 BEND X-43 RFPT 11 TB 0 .250 SP-GBD-152-) K185 P43607 RFPT C MN STM DRAIN 679 T-114 20.48 8 . 167 D.28 HAND GRID 9'N23-Ii'EK Ko)85-01 X-RIOB RESP95 SPGFD1026-E2 VALVE X-106 RFPT 7 TB 0 . 28) SP-GFD-102-6 K-)87 P43608 XAROUND STM RFPT HDR OR )-27-005 1.5 682 T-113 27.65 8 . 187 D.25 I'N22-3'WK KO)87-0)

X-RIOB RESP95 SPHAD)0731-El 90 ELBOW X-39 RFPT 11 TB 0 . 218 SPHAD-1073-1 K174 P4360)

RFPT 8 XAROUND STEAM DRAIN 680 T-115 24.5 8 . 145 D.25 Zl-HAND GRID 9'S21-2'EK KO)74-01 X-R IOB RESP95 SPHAD10731-E2 ELBOW X-41 RFPT 7 TB 13 .218 SPHAD-1073-1 K-609 P43775 RFPT XAROUND HDR DRAIN 673 T-36 19. 17 8 .)45 D.25 3'N22-3'WK K0609-O'I X-RIOB RESP95 SPHAO)691-E2 90 ELBOW X-1 19 TS 2 TB 0 . 179 SP-HAD- 169-1 K175 P43602 SSE-BLOWOOWN HV-)0761 681 T-) 13 35 8 . 1)9 D.55 HAND GRID 2'S18-3'WHB K0175-01 X-RIOB RESP95

GE NUMBER 21 UNIT 1-BRIO EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPHBD10051-E 1 ELBOW X-161 TS 6 TB 2 . 179 SPHBD-1005- I K-610 P43776 STEAM SEAL HEADER DRAIN 703 T-211 16. 16 8 . 119 D.77 9'N19-5'EHE K0610-01 X-RIOB RESP95 SPHBD10051-E2 ORIFICE X-160 TS 6 TB 5 . 179 SPHBD-1005-1 K-611 P43777 STEAM SEAL HEADER DRN FO-10722 706 T-21 1 16. 66 8 . 1'19 D.77 10'N18-3'EHE K061 1-0 I X-RIOB RESP95 SPHBD10721-E I 90 ELBOW X-40 RFPT 7 TB 0 . 218 SPHBD-1072-1 K190 P43609 RFPT C XAROUND DRAIN 680 T-1 '14 35. 61 8 . 145 D.26 Z I-TEMP 8'523-2'EK K0190-0 I X-RIOB RESP95 SPHBD10851-E2A REDUCER X-215A RFPT 7 TB 11 .200 SPHBD-1085-1 K-612 P43778 C RFPT 1ST STAGE DRAIN 669 T-36 0.0 8 . 133 D. 108 8'S22-12'WK K0612-01 X-RIOB RESP95 SPHBD 10851-E28 REDUCER X-2158 RFPT 7 TB 11 . 191 SPHBD-1085-1 K-612 P43778 C RFPT 1ST STAGE DRAIN 1.25 669 T-36 0.0 8 . 127 D. 108 8'S22-12'WK K0612-0 I X-R I 08 RESP95 SPHBD 1 091-E1 90 ELBOW X-204 EXTST 6 TB 7 . 218 SP-HBD-109-1 K-613 P43779 EXTRACTION 3A DRAIN 706 T-21'I 24.65 8 . 190 0.97 2'N19-8'EHE K0613-01 X-RIOB RESP95 SPH801091-E2 VALVE X-203 EXTST 6 TB 4 .218 SP-HBD-109-1 K161 P43663 EXTRACTION 3A DRAIN HV-'10203A 706 T-211 39.72 8 . 145 D.97 Zi-TEMP 1 '18-8 'HE K0161-01 X-RIOB RESP95

GE NUMBER 22 UNIT I-BRIO -- EROSION/CORROSIOn EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE? 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPHBD'1092-El 90 ELBOW X-205 EXTST 7 TB 0 .218 SP-HBD-109-2 K-614 P43780 EXTRACTION 3C DRAIN 701 T-211 41.09 8 . 190 0.98 4'N23-2'WHE K0614-01 X-RIOB RESP95 SPHBD1104-E2 90 ELBOW X-198 EXTST 7 TB 5 . 218 SP-HBD- I 10-4 K 165 P43664 EXTRACTION 4C DRAIN 708 T-21'I 26.03 8 . 145 D.92 Z I-TEMP ~ 9'N23-10'EHE K0165-01 X-RIOB RESP95 SPHBD1105-E2 90 ELBOW X-28 EXTST 7 TB 5 . 218 SP-HBD-110-5 K166 P43665 EXTR 4C DRAIN (IBC) 708 T-211 30.13 8 . 145 D. 14 Z I-TEMP 9'N24-4'WK K0166-01 X-RIOB RESP95 SPHB01107-El 90 ELBOW X-200 EXTST 6 TB 6 . 2'IB SP-HBD-110-7 K167 P43666 EXTRACTION 48 DRAIN 710 T-211 35.62 8 . '145 0.94 Zl, Z3 TEMP 6'N19-4'WK K0167-0 I X-RIOB RESP95 SPHBD1108-E2 90 ELBOW X-27 EXTST 7 TB 12 .218 SP-HBD- 110-8 K168 F43597 EXTR 48 DRAIN (058) 7 14 T-2'll 89.04 8 .145 D. 13 Zl-TEMP '7 '21- 10 'HE M59222 K0 168-01 X-RIOB RESP95 SPHBD1185-El OAIF ICE X-611 RFPT 5 TB 8 . 179 SP-HBD-118-5 K-615 P43781 SIS? NONE 686 T-113 15.00 8 . I19 D.161 8'S15-10'WK K0615-0 I X-RIOB RESP95 SPHB01391-E I VALVE X-2 16 FW 3 TB I I .179 SP-HBD-139- 'I K-616 F43782 AFP DISCHARGE RELIEF VALVES 670 T-36 0. 0 8 . 119 D. 109 7'N21-4'EGA K0616-01 X-R IOB RESP95

AfiE NUMBER 23 UNIT 1-BRIO -- EROSION/CORROSION EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPHBD148 I -E 1 BEND X- I 02 MCPR 2 TB 0 . I79 SP-HBD-148-1 K171 P43599 MAIN STEAM TO SJAE DRN 680 T-113 33.35 8 .1I9 D.49 HAND GRID 4'N18-5'WHB K0171-0 I X-RIOB RESP95 SPHBD1483-E 1 VALVE X-100 MCPR 2 TB 0 . 179 SP-HBD-148-3 K I 73 F43600 MAIN STEAM TO SJAE DRN 1-07-054 681 T-113 26.6 8 . 119 D.49 HAND GRID OBS 4'N18-9'WHB K0173-0 I X-RIOB RESP95 SPHBD 1711-El VAI VE X-116 TS 6 TB 7 . 179 SP-HBD-171-1 K553 P43740 SSE VENT AFTER HV-10728 686 T-113 3'1.67 8 . 119 0.54 10'N18-4'EHB K0553-01 X-R IOB RESP95 SPHBD1713" E I ORIFICE X-1 I5 TS 9 TB 0 .179 SP"HBD- I71-3 K554 F4374 I SSE VENT AFTER FO-10728 729 T-4I6 18.33 8 .119 D.54 6'N16-5'EL K0554-01 X-RI08 RESP95 SPHBD302310-Ei BEND X-634 AUX BLR 9 TB 10 . 200 SPH803023-10 K200 F436'15 SIS: NONE 1.5 669 T-52 113.4 8 . 133 D. 184 HAND GRID 4'S I5-12'EL M59211 K0200-OI X-RIOB RESP95 SPHBD302312-E 1 90 ELBOW X-635 AUX BLR 9 TB 14 .'154 SPHBD3023-'12 K201 F43616 SIS: NONE .75 672 T-52 35.29 8 . I03 D.184 HAND GRID 4'SI5-7'EK K0201-0 I X-RI08 RESP95 SPHBD3023I9-EI 90 ELBOW X-632 AUX BLR 23 TB 10 . 179 SPHBD3023-19 K202 F43617 SIS: NONE 669 T-51 25.0 8 . 119 D. 183 HAND GRID 4'S40- l4'WM K0202"01 X-RIOB RESP95

PAGE NUMBER 24 UNIT 1-BRIO EROSION/CORROSION FXAMS REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DES CRI PTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE SPHB030234-EI 90 ELBOW X-636 AUX BI.R 5 TB 10 .200 SPHBD3023-4 K 197 P43612 SISz NONE 1.5 669 T-44 35.82 8 . 133 D. 184 HAND GRID 3'N14-2'WJB K0197-01 X-RIOB RESP95 SPHBD30234-E2 BEND X-637 AUX BLR 5 TB 8 .200 SPHBD3023-4 K'198 F43613 S IS: NONE 711 T-217 47.46 8 . 133 D. 184 HAND GRID 10'N15-3'WJB M59212 KO 198-01 X-RIOB RESP95 SPHBD30234-E3 90 ELBOW X-638 AUX BI.R 5 TB 8 .200 SPHBD3023-4 K199 F43614 SI 5: NONE 1.5 711 T-217 53.73 8 . 133 D. 184 HAND GRID 4'S14-6'WJB M59205 K0 199-01 X-RIOB RESP95 SPHC01041-E4 VALVE X-622 CRD 11 TB 0 . 133 SP-HCD-104-1 K-617 F43783 SIS: X-624 661 T-52 27.27 8 .089 D. 133 5'S24-0'8KC K0617-01 X-RIOB RESP95 SSH-E3A REDUCER X 187A TS 9 TB 8 .406 SSH K-593 P43701 SSE OUTLET 12 741 T-416 36.76 8 .270 0.87 6'N15- I 'EL K0593-Oi X-RIOB RESP95 SSH-E38 REDUCER X-1878 TS 9 TB 8 .322 SSH K-593 P4370 I SSE OUTLET 8 741 T-416 0.0 8 .214 0.87 6'N15-1'EL K0593-01 X-R IOB RESP95 VNBB211-E1 90 ELBOW X-459 MS 26 RB 15 1 . 138 VNBB-21 1-1 K148 F43656 MS LINE C 26 787 R-516 40.75 M .893 D.B I Zi 8 Z2-HAND GRID 252 AZ-19-RCL K0 148-01 X-RI08 RESP95

GE NUMBER 25 UNIT 1-BRIO -- EROSION/CORROSION EXAMS REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE VN88211-E3 45 ELBOW X-460 MS 26 RB 10 1. 138 VN88211-1 K 149 F43657 SI S: X-174, 460, 462 26 750 R" 516 33.20 M .893 D. 150 Zl, Z2 TEMP 288AZ-26RCL K0 149-01 X-RIOB RESP95 VNBB212-E3 90 ELBOW X-462 MS 26 RB 0 'I. 138 VNBB212-1 K151 P43658 SIS X 174 EXISTING GRID

'60 '64 26 741 108AZ-28RCL R-516 21. 13 M .893 D.149 K0151-01 X-R IOB RESP95 1SCVL-E12 ELBOW X-173 TS 6 TB 14 .200 1SCVL K-557 F43668 1.5 716 T-211 32.83 8 . 133 D.41 6'N18-6'WJC K0557-0 I X-R I 08 RESP95 I SLCI V-E19 ELBOW X-98 TS 6 TB 12 .200 1SLCIV K559 F43670 CIV-CSV STEAM LEAKOFF 1.5 743 T-420 28.35 8 . 133 0.48 HNAD GRID 2'519-8'EJ K0559-01 X-RIOB RESP95 1SLCIV-E2 ELBOW X-572 TS 7 TB 0 . 200 1SLCIV K-558 P43669 SIS: X-403, 405, 407, 568, 570 729 T-419 29.85 8 . 133 D.48 1 '23-21 'G K0558-01 X-RIOB RESP95 1SSH7-E3 90 ELBOW X-189 TS 7 TB 21 . 258 1SSH-7 K-560 F43671 SSE SUPPLY HEADER 731 T-420 6.97 8 . 172 0.88 I 'S22-14'EHB K0560-01 X-RIOB RESP95 1SSHB-E25A REDUCER X- I BBA TS 7 TB 21 . 280 1SSH-8 K-561 P43672 SSE SUPPLY HEADER 8 723 T-211 0.0 8 . '186 D.BB 4'N22-O'JB K0561-01 X-RIOB RESP95

C liE NUMBER 26 UNIT I-BRIO -- EROSION/CORROSIOn EXAMS -- REPORT 2 (SORTED BY PRIORITY)

REPORT DATE: 06/28/95 COMPONENT ID DESCRIPTION REPLCD ID SYSTEM AREA BUILD SCAFF NOM WALL LINE MAP NO. WA NO DETAIL PLAN SIZE ELEV ROOM ERATE INSUL MIN WALL ISI ISO ACC 2 LINE GRID EWRNUM MEAS MIN ACTIVITY NO COMMENTS EXM SCH OUT DTE 1SSHB-E258 REDUCER X1888 TS 7 TB 21 .258 1SSH-8 K-561 P43672 SSE SUPPLY HEADER 723 T-211 11. 62 8 . 172 D.BB 4'N22"O'JB K0561-01 X-RIOB RESP95 2SCVL-E13 90 ELBOW X-90 TS 6 TB 12 .200 2SCVL K194 P43610 CV LP STEAM LEAKOFF 1.5 715 T-211 35.82 8 . 133 D. 41 HAND GRID 6'N19-4 'JC K0194-01 X-RIOB RESP95 2SLMSV"E22 ELBOW X-86 TS 6 TB 9 . 179 2SLMSV K-562 P43673 MSV SEALING STEAM 711 T 2'l l 28 33 8 . 119 D.41 8'N18-1 'EJC K0562-0 I X-RIOB RESP95 3SCVL-E14 BEND X-9 1 TS - 6 TB 12 . 147 3SCVL K195 P43611 CV SEALING STEAM 716 T-211 27. 65 8 . 100 D.41 HAND GRID 3'S'17-4'EJC K0195-01 X-RIOB RESP95 TOTAL EXAMS: 179 ECRPT2

IAJREG-0313 CATEGORY C WELDS FOR MS~P

APPL'NDI MSIP WELD LISTING UNIT 1

)Veld Weld Size Description Out Area Room Elev CI103 lYA Ident iTica lion a e S stent Nuniber I DBB-107-1-1-8 24 RHR Div I ln'et FOISA & F017A E-P 8 29 202 710 RHR I S43957 2 DBB-107 I-A 24 RHR Div II In Bet F0158 & F0178 P-E 8 28 202 711 RIIR II S43956 3 D8 8-107 I-D 24 RkIR Div II In Bet F0158 & F0178 E-P 7 28 202 711 RHR II 4 DCA-108-I-FW-12 20 Com SDC Suet at F008 V-E 7 28 203 710 SDC Coin 5 DCA-110-I-FW-I 24 RHR Div I In't FOISA P-V 8 29 202 710 RI IR I S43955 6 DCA-110-2-FW-I 24 RHR Div II hi't F0158 P-V 7 28 202 710 RHR II 7 DCB-102-I-FW-I 6 Head S ra U strm of F023 P-V 8 29 202 711 RIIR I S43954 8 DCB-102-I-FW-2 6 Head S ra Dnstrin of I 023 V-Fll 7 29 202 711 RHR I 9 DCB-102-I-FW-4 6 Head S ra Bet F022 & F023 FII-E 7 26 206 711 Rl IR I 10 G8 8-I 17- I-1-C 6 Head S ra Bet F023 & kIVI5112 E-P 7 29 202 711 RHR I 1 I HBB-111-I-I-A 20 Com SDC Suet DNSTRM of F008 E-RED 7 28 202 711 S DC Com 12 N I A NOZ-SE 28 "A" Recirc Pum Suet NOZ-SE 7 26 516-1 746 RHR I 13 N I 8 NOZ-SE -

28 "8" Recirc Pum Suet NOZ-SE 26 516-1 746 SDC 8 . Com S43947 14 N2A NOZ-SE 12 Recirc Pum Riser SE-NOZ 7 26 516-1 745 RI I R II 15 N2B NOZ-SE 12 Recirc Pum Riser SE-NOZ 8 26 516-1 745 RHR II S43948 16 N2C NOZ-SE 12 Recirc Pum Riser SE-NOZ 8 26 516-1 745 RHR II S43949 17 N2D NOZ-SE 12 Recirc Pum Riser SE-NOZ 8 26 516-1 745 RHR ll S43950 18 N2E NOZ-SE 12 Recirc Pum Riser Si:-NOZ 8 26 516-1 745 RHR II S43951 l9 N2F NOZ-SE 12 Recirc Pum > Riser (SE-NOZ 7 26 516-1 745 Rkl R I

h

- APPENDIX MSIP WELD LISTING VNIT 1 Wekl Weld Size Description Out Area Room Elev C 1103 WA Identification a e S stem Number 20 N2G NOZ-SE 12 Recirc Pum Riser SE-NOZ 8 26 516-1 745 RHR I S43952 21 N2H NOZ-SE 12 Recirc Pum Riser SE-NOZ 8 26 516-1 745 RHR I S43953 22 N2J NOZ-SE 12 Recirc Pum Riser Sl:-NOZ 7 26 516-1 745 RHR I 23 N2K NOZ-SE 12 Recirc Pum Riser SE-NOZ 7 26 516-1 745 RHR I 24 NSA NOZ-SE 10 CS DIV II In'ozzle SE-NOZ 8 26 516-3 772 CS Non S43958 25 N5A NOZ-SEXT 10 CS DIY II In'ozzle Sext-SE 8 26 516-3 772 CS Non S43959 26 NSB NOZ-SE 10 CSDIVI In Nozzle SE-NOZ 8 26 516-3 772 CS Non S43960 27 NSB NOZ-SEXT 10 CSDIV I In Nozzle Sext-SE 8 26 516-3 772 CS Non S43961 28 N8A NOZ-SE 4.5 Cal Jet Pum Inst Line NOZ-SE 8 26 516-1 745 NB Non S43962 29 N8A NOZ-PEN SEAL 4 Cal Jet Pum ) Inst Line SE-Pen Seal 8 26 516-1 745 NB Non S43963 30 N8B NOZ-SE 4.5 Cal Jet Pum Inst Line NOZ-SE 8 26 516-1 745 NB Non S43964 31 N8B NOZ-PEN SEAL 4 Cal Jet Pum Inst Line SE-Pen Seal 8 26 516-1 745 NB Non S43965 32 N9 NOZ-CAP 4 CRD to RPV Return (NOZ-CP 7 26 516-3 770 CRD Non