ML16120A604: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 2: | Line 2: | ||
| number = ML16120A604 | | number = ML16120A604 | ||
| issue date = 04/18/2016 | | issue date = 04/18/2016 | ||
| title = | | title = Final Safety Analysis Report Update, Revision 32, Chapter 10 - Steam and Power Conversion System - Tables | ||
| author name = | | author name = | ||
| author affiliation = Entergy Nuclear Operations, Inc | | author affiliation = Entergy Nuclear Operations, Inc |
Latest revision as of 03:07, 3 April 2019
ML16120A604 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 04/18/2016 |
From: | Entergy Nuclear Operations |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML16120A302 | List:
|
References | |
PNP 2016-015 | |
Download: ML16120A604 (6) | |
Text
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEMTABLE 10-4Revision 30Page 1 of 2COOLING TOWER DESIGN
SUMMARY
(SPX MARLEY TOWER E-30A)Number of Towers 1Number of Cells16/Tower TypeInduced/Cross FlowPerformance at Design Point Hot Water Flow, gpm 185,000 Approach Temperature, °F 112.77 Range, °F 32 Cold Water Temperature, °F 80.77 Fan Brake Horsepower, bhp 166 Pumping Head Above Sill, ft 90Fans and Fan Motors Number of Fans 16 Number of Blades 9 Blade Diameter, ft 28 Blade MaterialFiberglass Reinforced Vinyl Ester Tip Speed, ft/s 196 Fan Speed, r/min 134 Rated hp/Voltage 200/460V FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEMTABLE 10-4Revision 30Page 2 of 2COOLING TOWER DESIGN
SUMMARY
(ECODYNE TOWER E-30B)Number of Towers 1Number of Cells18/Tower TypeInduced/Cross FlowPerformance at Design Point Hot Water Flow, gpm 205,000 Approach Temperature, °F 107 Range, °F 30 Cold Water Temperature, °F 77 Fan Brake Horsepower, bhp 193 Pumping Head Above Sill, ft 90Fans and Fan Motors Number of Fans 18 Number of Blades 8 Blade Diameter, ft 28 Blade MaterialFiberglass Reinforced Polyester Tip Speed, ft/s 198 Fan Speed, r/min 135 Rated hp/Voltage 200/460V
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEMTABLE 10-4Revision 30Page 1 of 2COOLING TOWER DESIGN
SUMMARY
(SPX MARLEY TOWER E-30A)Number of Towers 1Number of Cells16/Tower TypeInduced/Cross FlowPerformance at Design Point Hot Water Flow, gpm 185,000 Approach Temperature, °F 112.77 Range, °F 32 Cold Water Temperature, °F 80.77 Fan Brake Horsepower, bhp 166 Pumping Head Above Sill, ft 90Fans and Fan Motors Number of Fans 16 Number of Blades 9 Blade Diameter, ft 28 Blade MaterialFiberglass Reinforced Vinyl Ester Tip Speed, ft/s 196 Fan Speed, r/min 134 Rated hp/Voltage 200/460V FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEMTABLE 10-4Revision 30Page 2 of 2COOLING TOWER DESIGN
SUMMARY
(ECODYNE TOWER E-30B)Number of Towers 1Number of Cells18/Tower TypeInduced/Cross FlowPerformance at Design Point Hot Water Flow, gpm 205,000 Approach Temperature, °F 107 Range, °F 30 Cold Water Temperature, °F 77 Fan Brake Horsepower, bhp 193 Pumping Head Above Sill, ft 90Fans and Fan Motors Number of Fans 18 Number of Blades 8 Blade Diameter, ft 28 Blade MaterialFiberglass Reinforced Polyester Tip Speed, ft/s 198 Fan Speed, r/min 135 Rated hp/Voltage 200/460V