Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20011A419 + (10:05:22, 21 December 2024)
- 05000249/LER-1981-023-03, /03L-0:on 810904,while Conducting Quarterly Scram Discharge Vol Continuous Level Monitor Calibr Check,West & East Bank/East Transducer high-high Level Alarm Tripped. Caused by Setpoint Drift + (10:05:24, 21 December 2024)
- 0CAN108102, Forwards Info Re Diesel Generator History,Per NRC 810709 Request Concerning Station Blackout + (10:05:26, 21 December 2024)
- JAFP-81-1049, Forwards Monthly Operating Rept for Sept 1981 + (10:05:28, 21 December 2024)
- ML20011A416 + (10:05:28, 21 December 2024)
- 05000249/LER-1981-023, Forwards LER 81-023/03L-0 + (10:05:31, 21 December 2024)
- 05000324/LER-1981-084-03, /03L-0:on 810909,discrepancy Noted in Suppression Chamber Water Level Recorders.Caused by Change in Trickle Flow to Wet Ref Leg of Recorder Transmitter 2-CAC-LT-2602. Flow re-established & Transmitter Calibr + (10:05:33, 21 December 2024)
- ML20011A410 + (10:05:34, 21 December 2024)
- 05000324/LER-1981-084, Forwards LER 81-084/03L-0 + (10:05:36, 21 December 2024)
- ML20011A407 + (10:05:37, 21 December 2024)
- IR 05000333/1981018 + (10:05:43, 21 December 2024)
- ML20011A404 + (10:05:44, 21 December 2024)
- ML20011A403 + (10:05:45, 21 December 2024)
- ML20011A400 + (10:05:46, 21 December 2024)
- ML20011A399 + (10:05:48, 21 December 2024)
- ML20011A398 + (10:05:49, 21 December 2024)
- ML20011A397 + (10:05:49, 21 December 2024)
- ML20011A396 + (10:05:50, 21 December 2024)
- 05000281/LER-1981-056-03, /03L-0:on 810902,RCS Cold Leg Sample Valve Opened W/O Operator Action & Would Not Stay Closed.Caused by Failure of seal-in Limit Switch in Valve Operator.Lock Nuts Became Loose Due to Vibration & Valve Usage + (10:05:52, 21 December 2024)
- ML20011A393 + (10:05:53, 21 December 2024)
- ML20011A392 + (10:05:54, 21 December 2024)
- ML20011A391 + (10:05:55, 21 December 2024)
- ML20011A390 + (10:05:56, 21 December 2024)
- ML20011A389 + (10:05:57, 21 December 2024)
- ML20011A388 + (10:05:58, 21 December 2024)
- 05000281/LER-1981-056, Forwards LER 81-056/03L-0 + (10:05:59, 21 December 2024)
- ML20011A383 + (10:06:01, 21 December 2024)
- ML20011A382 + (10:06:02, 21 December 2024)
- ML20011A380 + (10:06:03, 21 December 2024)
- ML20011A379 + (10:06:04, 21 December 2024)
- ML20011A377 + (10:06:05, 21 December 2024)
- ML20011A378 + (10:06:05, 21 December 2024)
- ML20011A376 + (10:06:07, 21 December 2024)
- 05000334/LER-1981-081-03, /03L-0:on 810827,level in Primary Demineralized Water Storage Tank Fell Below Tech Spec After Auxiliary Feed to Steam Generators Was Initiated Following Pump Trip.Caused by Feed Demand Exceeding Tank Supply Rate + (10:06:09, 21 December 2024)
- ML20011A372 + (10:06:10, 21 December 2024)
- ML20011A371 + (10:06:11, 21 December 2024)
- ML20011A370 + (10:06:11, 21 December 2024)
- ML20011A369 + (10:06:12, 21 December 2024)
- ML20011A368 + (10:06:13, 21 December 2024)
- 05000334/LER-1981-081, Forwards LER 81-081/03L-0 + (10:06:15, 21 December 2024)
- ML20011A363 + (10:06:16, 21 December 2024)
- ML20011A362 + (10:06:17, 21 December 2024)
- ML20011A361 + (10:06:18, 21 December 2024)
- IR 05000333/1981008 + (10:06:19, 21 December 2024)
- ML20011A358 + (10:06:21, 21 December 2024)
- ML20011A357 + (10:06:28, 21 December 2024)
- IR 05000309/1981022 + (10:06:30, 21 December 2024)
- ML20011A355 + (10:06:31, 21 December 2024)
- ML20011A353 + (10:06:32, 21 December 2024)
- ML20011A351 + (10:06:33, 21 December 2024)
- ML20011A350 + (10:06:34, 21 December 2024)