KANSAS GAS AND ELECTRIC COMPANY THE ELECTF4tC COMPANY OLENN L MOESTER vect massoa%f Nuttaan October 1,1981 W
Mr. G.L. Madsen, Chief f e,
,d @'
N Reactor Projects Branch C
U.S. Nuclear Regulatory Commission Region IV
/d j
7,,.
611 Ryan Plaza Drive 1[
OCT 819815-w Suite 1000
-3 Arlington, Texas 76011 T
w usuAID.:
wmot
,p o
KMLNRC 81-117 j%j Re:
NRC Docket No. STN 50-482 N (#a8 l T Ref:
Interim Report dated July 15, 1981 transmitted T GLKoester Letter (KMLNRC 81-099) to GLMadsen, NRC Subj: Interim 50.55(e) Report on Nuclear Coatings in the Reactor Building
Dear Mr. Madsen:
This letter is to provide an update on the evaluation of the nuclear coatings applied in the Reactor Building of the Wolf Creek Generating Station, Unit No. 1.
During the documentation search, the Constructor has found some of the missing documentation. This information has been transmitted to the Architect / Engineer for their evaluation and recommendations. The Architect / Engineer has indicated that they will complete their evaluation and provide recommendations by the end of October.
The status of the documentation evEluation and/or' 'a schedule for adhesion pull tests, if required, will be reported to you on or before November 20, 1981.
If you require any addigional information, please feel free l'
to contact us.
Yours very truly, k f.'IJ GLK:bb cc: Mr. Thomas Vandel yp Resident NRC Inspec 7,,
s o
ef-hh h
8110090 2
DR ADO 0
'r g
201 N. Market - Wictuta, Kansas - Marl Addres
. Box
! wh.