Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19318A616 + (01:58:48, 2 January 2025)
- ML19318A615 + (01:58:48, 2 January 2025)
- ML19318A614 + (01:58:49, 2 January 2025)
- ML19318A613 + (01:58:50, 2 January 2025)
- ML19318A609 + (01:58:52, 2 January 2025)
- ML19318A610 + (01:58:52, 2 January 2025)
- IR 05000309/1980002 + (01:58:54, 2 January 2025)
- ML19318A607 + (01:58:55, 2 January 2025)
- 05000339/LER-1980-020-03, /03L-0:on 800529,during Mode 3 condition,72-h Periodic Test of Containment Personnel Hatch Was Not Accomplished Due to Failure of Doors to Close.Caused by Failure of Limit Switch on Inner Door.Switch Replaced + (01:58:57, 2 January 2025)
- ML19318A603 + (01:58:58, 2 January 2025)
- ML19318A602 + (01:58:59, 2 January 2025)
- 05000339/LER-1980-020, Forwards LER 80-020/03L-0 + (01:59:03, 2 January 2025)
- ML19318A599 + (01:59:05, 2 January 2025)
- ML19318A597 + (01:59:07, 2 January 2025)
- ML19318A593 + (01:59:09, 2 January 2025)
- ML19318A594 + (01:59:09, 2 January 2025)
- ML19318A592 + (01:59:11, 2 January 2025)
- ML19318A591 + (01:59:11, 2 January 2025)
- ML19318A590 + (01:59:12, 2 January 2025)
- 05000339/LER-1980-013-03, /03L-0:on 800520 & 27,w/unit in Hot Standby, Samples of Boron Injection Tank & C Boric Acid Storage Found to Contain Less than 20,000 Ppm Boron.Caused by Leaks Past Inlet Valves MOV-2867 a & B.Switch Settings Increased + (01:59:13, 2 January 2025)
- 05000339/LER-1980-013, Forwards LER 80-013/03L-0 + (01:59:14, 2 January 2025)
- ML19318A586 + (01:59:15, 2 January 2025)
- ML19318A585 + (01:59:16, 2 January 2025)
- ML19318A584 + (01:59:24, 2 January 2025)
- ML19318A583 + (01:59:25, 2 January 2025)
- ML19318A582 + (01:59:26, 2 January 2025)
- 05000254/LER-1980-015-03, /03L-0:on 800511,during Manual Operation of Relief Valves,Valve 1-203-3B Failed to Open.Hpci & Other Valves Operable.Caused by Dirty Contact on Valve Operator hold-in Coil Switch.Switch Replaced & Valve Returned to Svc 80051 + (01:59:27, 2 January 2025)
- 05000254/LER-1980-015, Forwards LER 80-015/03L-0 + (01:59:28, 2 January 2025)
- ML19318A578 + (01:59:29, 2 January 2025)
- ML19318A576 + (01:59:30, 2 January 2025)
- ML19318A575 + (01:59:31, 2 January 2025)
- ML19318A574 + (01:59:32, 2 January 2025)
- ML19318A573 + (01:59:33, 2 January 2025)
- ML19318A572 + (01:59:34, 2 January 2025)
- ML19318A571 + (01:59:35, 2 January 2025)
- ML19318A570 + (01:59:36, 2 January 2025)
- 05000348/LER-1980-032-03, /03L-0:on 800515,both Chlorine Detectors Were Inoperable.Caused by Plastic Strip Lodged in B Detector & Cracked Diaphragm in a Detector.Strip Removed & B Made Operable on 800515.Pump Replaced & a Operable on 800516 + (01:59:37, 2 January 2025)
- ML19318A567 + (01:59:39, 2 January 2025)
- ML19318A566 + (01:59:40, 2 January 2025)
- IR 05000369/1980007 + (01:59:41, 2 January 2025)
- ML19318A564 + (01:59:42, 2 January 2025)
- ML19318A562 + (01:59:44, 2 January 2025)
- ML19318A563 + (01:59:44, 2 January 2025)
- ML19318A561 + (01:59:45, 2 January 2025)
- 05000348/LER-1980-033-03, /03L-0:on 800516,1-2A Diesel Generator Declared Inoperable Due to Speed Control Failure.Caused by Personnel Error in Installing Dc Recorder Which Blew Ac Fuse.Fuse Replaced,Personnel Instructed + (01:59:46, 2 January 2025)
- ML19318A558 + (01:59:47, 2 January 2025)
- ML19318A557 + (01:59:47, 2 January 2025)
- ML19318A556 + (01:59:48, 2 January 2025)
- ML19318A555 + (01:59:49, 2 January 2025)
- IR 05000327/1980014 + (01:59:51, 2 January 2025)
- ML19318A553 + (01:59:52, 2 January 2025)