Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20064C280 + (02:06:12, 17 December 2024)
- 05000266/LER-1978-014-01, /01T-0:on 780920,primary-to-secondary Leakage Noted During Normal Operation.Caused by Two Leaking Tubes & One Leaking Plug on Inlet Side of Steam Generator A.Tubes Will Be Plugged & Plug Will Be Weld Repaired + (02:06:14, 17 December 2024)
- ML20064C277 + (02:06:15, 17 December 2024)
- 05000266/LER-1978-014, Forwards LER 78-014/01T-0 + (02:06:16, 17 December 2024)
- ML20064C268 + (02:06:20, 17 December 2024)
- U-602257, Proposed TS 3/4.4.3.1, RCS Leakage-Leakage Detection Sys + (02:06:21, 17 December 2024)
- 05000265/LER-1994-002-04, :on 940127,control Rods M-8 & M-6 Mispositioned During Testing.Caused by Inappropriate Work Practices,Mgt/ Supervisory Methods & Verbal Communications.Rods M-8 & M-6 Returned to Position 00 + (02:06:23, 17 December 2024)
- 05000219/LER-1978-017-03, /03L-0:on 780914,circuit Breaker for motor- Operated Valve Tripped When Valve Closed by Isolation Signal.Caused by Component Failure Allowing Switch Setting to Shift.Setting Corrected & Set Screw Tightened + (02:06:25, 17 December 2024)
- JSP-079-94, Application for Amend to License NPF-62,revising TS 3/4.4.3.1, RCS Leakage-Leakage Detection Sys, in Response to Inoperability of Drywell Floor Drain Sump Flow Rate Monitoring Instrumentation + (02:06:26, 17 December 2024)
- 05000219/LER-1978-017, Forwards LER 78-017/03L-0 + (02:06:27, 17 December 2024)
- ML20064C237 + (02:06:28, 17 December 2024)
- ML20064C239 + (02:06:28, 17 December 2024)
- ML20064C234 + (02:06:40, 17 December 2024)
- ML20064C232 + (02:06:40, 17 December 2024)
- ML20064C230 + (02:06:41, 17 December 2024)
- ML20064C228 + (02:06:42, 17 December 2024)
- ML20064C227 + (02:06:42, 17 December 2024)
- ML20064C225 + (02:06:45, 17 December 2024)
- 05000368/LER-1978-003-03, /03L-0:on 780912,during Mode 3 Operation,Cst B Level Dropped to Less than 80% W/Cst a at About 10%.Caused by Inability of Makeup Tank to Produce Enough Quality Water to Maintain Level + (02:06:47, 17 December 2024)
- 05000259/LER-1982-095-03, /03L-0:on 821201,while Performing Diesel Generator B Redundant Start Tests,Faulty Relay Found.Caused by Burned Contact Due to Normal Wear While Stuck in Closed Position. Relay Replaced + (02:06:49, 17 December 2024)
- ML20064C219 + (02:06:50, 17 December 2024)
- ML20064C218 + (02:06:52, 17 December 2024)
- ML20064C217 + (02:06:52, 17 December 2024)
- ML20064C211 + (02:06:53, 17 December 2024)
- ML20064C210 + (02:06:53, 17 December 2024)
- 05000265/LER-1994-002, Forwards LER 94-002-00.OGCP 4-1 Will Be Revised to Clarify Specific Requirements for Independent Rod Verification + (02:06:54, 17 December 2024)
- ML20064C206 + (02:06:55, 17 December 2024)
- 05000368/LER-1978-003, Forwards LER 78-003/03L-0 + (02:06:56, 17 December 2024)
- 05000259/LER-1982-095, Forwards LER 82-095/03L-0 + (02:06:59, 17 December 2024)
- ML20064C201 + (02:06:59, 17 December 2024)
- ML20064C190 + (02:07:00, 17 December 2024)
- ML20064C188 + (02:07:00, 17 December 2024)
- ML20064C184 + (02:07:01, 17 December 2024)
- 05000311/LER-1982-144-03, /03L-0:on 821126,light on Control Console Indicated Closed During Attempt to Open Nitrogen Supply Header Valve 2NT32.Caused by Internal Binding.Valve Closed & Leak Rate Test Performed + (02:07:02, 17 December 2024)
- ML20064C177 + (02:07:04, 17 December 2024)
- ML20064C171 + (02:07:05, 17 December 2024)
- ML20064C176 + (02:07:05, 17 December 2024)
- ML20064C169 + (02:07:06, 17 December 2024)
- ML20064C170 + (02:07:06, 17 December 2024)
- ML20064C166 + (02:07:07, 17 December 2024)
- ML20064C167 + (02:07:07, 17 December 2024)
- ML20064C163 + (02:07:08, 17 December 2024)
- ML20064C153 + (02:07:09, 17 December 2024)
- ML20064C156 + (02:07:09, 17 December 2024)
- 05000311/LER-1982-144, Forwards LER 82-144/03L-0.Detailed Event Analysis Encl + (02:07:10, 17 December 2024)
- ML20064C149 + (02:07:10, 17 December 2024)
- ML20064C147 + (02:07:11, 17 December 2024)
- ML20064C143 + (02:07:11, 17 December 2024)
- ML20064C142 + (02:07:12, 17 December 2024)
- ML20064C139 + (02:07:13, 17 December 2024)
- ML20064C134 + (02:07:14, 17 December 2024)