- ML20082P650 + (11:36:07, 14 December 2024)
- ML20082P647 + (11:36:08, 14 December 2024)
- 05000316/LER-1983-106-03, /03L-0:on 831105,analog Rod B-6 Control Bank B Pegged Low,W/Control Bank B Withdrawn to 228 Steps.Caused by Female Pins Pulling Back from Male Pins at Disconnector. Cable Repositioned to Eliminate Strain on Connector + (11:36:10, 14 December 2024)
- ML20082P644 + (11:36:10, 14 December 2024)
- ML20082P639 + (11:36:12, 14 December 2024)
- ML20082P629 + (11:36:13, 14 December 2024)
- ML20082P635 + (11:36:13, 14 December 2024)
- ML20082P626 + (11:36:14, 14 December 2024)
- ML20082P628 + (11:36:14, 14 December 2024)
- 05000316/LER-1983-105-03, /03L-0:on 831105,two Ice Condenser Intermediate Deck Doors Found Inoperable.Caused by Bracing Installed as Part of Design Change,Obstructing Doors.Bracing Modified + (11:36:16, 14 December 2024)
- 05000315/LER-1983-114-01, /01T-0:on 831118,during Venting of Vol Control Tank to Waste Gas Holdup Sys,Oxygen & Hydrogen Concentration Exceeded 4% Limit.Caused by Inadequate Procedures.Tank Vented.Communicating Procedures Revised + (11:36:18, 14 December 2024)
- RBG-35-502, Responds to NRC Re Violations Noted in Insp Rept 50-458/91-08.Corrective Actions:Installed NIST Time Base Signal + (11:36:19, 14 December 2024)
- PLA-1963, Forwards Change Q to Physical Security Plan.Change Withheld (Ref 10CFR2.790) + (11:36:19, 14 December 2024)
- ML20082P605 + (11:36:20, 14 December 2024)
- ML20082P606 + (11:36:20, 14 December 2024)
- ML20082P597 + (11:36:21, 14 December 2024)
- ML20082P604 + (11:36:21, 14 December 2024)
- ML20082P590 + (11:36:22, 14 December 2024)
- ML20082P587 + (11:36:23, 14 December 2024)
- 05000361/LER-1983-143, Has Been Canceled + (11:36:25, 14 December 2024)
- ML20082P582 + (11:36:26, 14 December 2024)
- ML20082P579 + (11:36:27, 14 December 2024)
- ML20082P576 + (11:36:28, 14 December 2024)
- ML20082P572 + (11:36:29, 14 December 2024)
- 05000443/LER-1991-001-01, :on 910810,source Range Neutron Flux Audible Monitors Discovered Inoperable.Caused by Personnel Error. Request for Engineering Svcs Initiated to Evaluate Feasibility of Design Change + (11:36:30, 14 December 2024)
- 05000315/LER-1983-113-01, /01T-0:on 831117,during Surveillance Testing,Loop 1 Overpower Delta Temp Rod Stop & Reactor Trip Bistable Failed in Trip State.Loop 2 Also Failed High.Cause Not Stated.Temp Rod Stop & Reactor Trip Replaced + (11:36:32, 14 December 2024)
- 05000317/LER-1991-006-01, :on 910724,reactor Protection Sys Channel B, Trip Unit 1 Taken Out of Bypass W/O Declaring Channel Operable or Placing Channel in Tripped Condition.Caused by Personnel Error.Shift Supervisor Counseled + (11:36:34, 14 December 2024)
- ML20082P565 + (11:36:35, 14 December 2024)
- ML20082P556 + (11:36:38, 14 December 2024)
- ML20082P561 + (11:36:38, 14 December 2024)
- ML20082P555 + (11:36:39, 14 December 2024)
- ML20082P554 + (11:36:40, 14 December 2024)
- ML20082P550 + (11:36:45, 14 December 2024)
- 05000361/LER-1983-140-03, /03L-0:on 831027,local Controller Shutoff Switch for Electrically Driven Fire Pump P221 Discovered Open.Cause Could Not Be Determined.Switch Closed & Pump Operability Restored + (11:36:47, 14 December 2024)
- 05000362/LER-1983-097-03, /03L-0:on 831029 & 30,control Element Assembly (CEA) 57 & on 831101,CEA 61,dropped More than 19 Inches. Caused by Sluggishness of CEA Grippers.Timing Sequences & Voltages Adjusted to Compensate + (11:36:49, 14 December 2024)
- ML20082P542 + (11:36:50, 14 December 2024)
- ML20082P539 + (11:36:50, 14 December 2024)
- ML20082P535 + (11:36:51, 14 December 2024)
- 05000370/LER-1991-004, :on 910422,auxiliary Feedwater turbine-driven Pump Declared Inoperable Due to Erroneous Calibr of Pump Suction Pressure Switches.Caused by Mgt & Design Deficiency.Pressure Switches Recalibr + (11:36:54, 14 December 2024)
- ML20082P528 + (11:36:55, 14 December 2024)
- ML20082P523 + (11:36:56, 14 December 2024)
- ML20082P521 + (11:36:56, 14 December 2024)
- ML20082P516 + (11:36:57, 14 December 2024)
- ML20082P506 + (11:36:58, 14 December 2024)
- ML20082P503 + (11:36:58, 14 December 2024)
- ML20082P502 + (11:36:59, 14 December 2024)
- 05000352/LER-1991-020-01, :on 910813,two Similar ESF Actuation Events Occurred After Reactor Water Level Indicating Switch Tripped Twice within Same Day.Cause of First Event Unknown & Second Event Caused by Personnel Error + (11:37:00, 14 December 2024)
- ML20082P471 + (11:37:01, 14 December 2024)
- ML20082P463 + (11:37:02, 14 December 2024)
- ML20082P457 + (11:37:04, 14 December 2024)
- ML20082P456 + (11:37:05, 14 December 2024)