- 05000285/LER-1991-024, :on 911106,ventilation Isolation Actuation Signal Received When Electrician Removed Wrong Fuse Block from Control Panel.Caused by Personnel Error.Standing Order Revised Re Pulling Fuses or Lifting Leads + (07:03:47, 14 December 2024)
- ML20086H933 + (07:03:49, 14 December 2024)
- ML20086H934 + (07:03:49, 14 December 2024)
- ML20086H931 + (07:03:50, 14 December 2024)
- ML20086H930 + (07:03:50, 14 December 2024)
- ML20086H929 + (07:03:51, 14 December 2024)
- 05000321/LER-1991-027, :on 911108,RWCU Leak Detection Sys Annunicator Alarm Received,Followed by Automatic Closure of Group 5 Primary Containment Isolation Valves.Caused by Improper Installation of Sensing Lines.Lines Examined + (07:03:53, 14 December 2024)
- ML20086H924 + (07:03:54, 14 December 2024)
- ML20086H923 + (07:03:54, 14 December 2024)
- ML20086H921 + (07:03:55, 14 December 2024)
- ML20086H920 + (07:03:55, 14 December 2024)
- ML20086H919 + (07:03:56, 14 December 2024)
- 05000483/LER-1991-006, :on 911105,reactor Trip Occurred Due to Failure of Gating/Sequencing Card in Inverter for 120 Volt Ac Instrument Bus.Card Will Be Sent to Vendor for Testing.W/ + (07:03:58, 14 December 2024)
- ML20086H916 + (07:03:59, 14 December 2024)
- ML20086H913 + (07:04:00, 14 December 2024)
- ML20086H912 + (07:04:00, 14 December 2024)
- ML20086H911 + (07:04:01, 14 December 2024)
- ML20086H908 + (07:04:02, 14 December 2024)
- ML20086H909 + (07:04:02, 14 December 2024)
- 3F1291-08, Tech Spec Change Request 193 to License DPR-72,changing Quadrant Power Tilt Spec 3.2.4 to Provide Exclusion for Spec 3.0.4 to Reflect steady-state Limits in Excess of 7% at 15% Full Power + (07:04:03, 14 December 2024)
- ML20086H904 + (07:04:03, 14 December 2024)
- 3F1291-09, Requests Temporary Waiver of Compliance from TS 3.0.4 as Applies to TS 3.2.4 Quadrant Power Tilt. Plant Restricted from Ascending Power Above 15% Rated Thermal Power W/Tilt Condition Present,Per Generic Ltr 87-09 + (07:04:04, 14 December 2024)
- ML20086H897 + (07:04:05, 14 December 2024)
- ML20086H900 + (07:04:05, 14 December 2024)
- ML20086H889 + (07:04:06, 14 December 2024)
- ML20086H893 + (07:04:06, 14 December 2024)
- ML20086H884 + (07:04:07, 14 December 2024)
- LD-91-060, Forwards Response to NRC 910808 Request for Addl Info on CESSAR Design Certification + (07:04:08, 14 December 2024)
- ML20086H877 + (07:04:08, 14 December 2024)
- ML20086H871 + (07:04:09, 14 December 2024)
- 05000366/LER-1991-020-01, :on 911105,protective Breaker on Output of motor-generator Set B in Reactor Protection Sys Tripped, Causing Loss of Power to Radiation Monitors.Caused by Spurious Actuation of Breaker.Voltage Adjusted + (07:04:11, 14 December 2024)
- LD-91-061, Forwards Response to NRC 910803 Request for Addl Info to Enable NRC to Continue Review of Engineering Std SAR for Design Certification + (07:04:12, 14 December 2024)
- 05000285/LER-1991-026, :on 911105,discovered That Senior Reactor Operator Did Not Have Current NRC Medical Exam.Caused by Lack of Single Point Control of NRC Medical Exam Program. Personnel Training Info Sys Upgraded + (07:04:14, 14 December 2024)
- 05000362/LER-1991-007-02, :on 911107,fuel Handling Bldg Train a Spuriously Actuated as Radiation Monitor 3RI-7822 Returned to Svc.Caused by Intermittent Failure of Internal to Normal/ Bypass Switch.Handswitch Replaced + (07:04:16, 14 December 2024)
- ML20086H857 + (07:04:17, 14 December 2024)
- RBG-16626, Forwards Public Version of Radiological Emergency Response Plans for States of La & Ms + (07:04:18, 14 December 2024)
- ML20086H855 + (07:04:19, 14 December 2024)
- ML20086H852 + (07:04:20, 14 December 2024)
- ML20086H849 + (07:04:20, 14 December 2024)
- ML20086H844 + (07:04:21, 14 December 2024)
- ML20086H843 + (07:04:21, 14 December 2024)
- ML20086H842 + (07:04:23, 14 December 2024)
- 05000298/LER-1991-015, :on 911105,discovered That as-found Setpoint for Safety/Relief Valves Not within Tech Spec Limit of Plus or Minus 1% (11 Psi).Caused by Setpoint Drift.Valves Inspected,Refurbished & Retested + (07:04:27, 14 December 2024)
- ML20086H840 + (07:04:28, 14 December 2024)
- 0CAN129104, Withdraws 911019 Application for Amends to Licenses DPR-51 & NPF-6,adding LCO & Surveillance Requirements for Main Steam Line Radiation Monitors,Per Generic Ltr 83-37.Proposed Changes to TS Being Prepared Per Generic Ltr 89-01 + (07:04:29, 14 December 2024)