Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20237D033 + (ML20237D033)
- ML20237D034 + (ML20237D034)
- ML20237D035 + (ML20237D035)
- ML20237D036 + (ML20237D036)
- ML20237D038 + (ML20237D038)
- IR 05000346/1998012 + (ML20237D039)
- ML20237D040 + (ML20237D040)
- ML20237D041 + (ML20237D041)
- 3F1287-15, Revises Implementation Schedule for Commitment to Provide Emergency Power Via Technical Support Ctr Diesel Generator for Security Lights.Mods Should Be Completed by End of First Quarter 1988 + (ML20237D044)
- 05000483/LER-1998-007, :on 980722,noted Failure to Verify Integrity of Balancing Devices on Psvs Per TS 4.0.5.Caused by Personnel Not Being Aware That Subject Psvs Had Balancing Devices.Will Continue to Test & Refurbish Valves Offsite + (ML20237D045)
- ML20237D046 + (ML20237D046)
- ML20237D047 + (ML20237D047)
- FVY-87-118, Requests Meeting W/Nrc to Discuss Status of Review of 860425 Application for Amend to License DPR-28,consisting of Change 133 Re Spent Fuel Expansion to Respond to Informational Requirements or Outstanding Questions Associated W/Review + (ML20237D048)
- ML20237D049 + (ML20237D049)
- 05000458/LER-1987-027, :on 871117,while Sys Valve line-ups Being Performed,Valve 1RCS-V122 Discovered Closed.Caused by Valve Not Being Signed Off as Opened During Initial Performance of Sys line-up in Aug 1985.Valve Repositioned + (ML20237D050)
- ML20237D051 + (ML20237D051)
- 05000412/LER-1987-036, :on 871117,I&C Technician Working in Control Room Bumped & Tripped Power Supply Switch to Turbine Thrust Bearing Circuit Supervisory Instrument.Caused by Several Factors,Including No Seal on Trip Relay + (ML20237D053)
- ML20237D054 + (ML20237D054)
- 05000259/LER-1987-001, :on 870127,no Fire Watch Posted Per Tech Specs When Hose Being Replaced on Fire Protection Sys.On 870210, Another Fire Watch Infraction Occurred When Personnel Reported to Wrong Cable Room + (ML20237D055)
- ML20237D056 + (ML20237D056)
- ML20237D057 + (ML20237D057)
- ML20237D059 + (ML20237D059)
- ML20237D061 + (ML20237D061)
- ML20237D062 + (ML20237D062)
- ML20237D063 + (ML20237D063)
- ML20237D064 + (ML20237D064)
- ML20237D066 + (ML20237D066)
- ML20237D067 + (ML20237D067)
- ML20237D068 + (ML20237D068)
- 3F1287-16, Requests Exemption Form 10CFR50,App a GDC 17.Fee Paid. Certificate of Svc Encl + (ML20237D070)
- ML20237D072 + (ML20237D072)
- ML20237D073 + (ML20237D073)
- ML20237D074 + (ML20237D074)
- 05000344/LER-1987-035, :on 871118,fire Doors Made Inoperable Due to Personnel Error.Caused by Procedural Inadequacy.Operability of Fire Detectors in Area Verified & Hourly Fire Patrol,Per Tech Spec 3.7.9,established + (ML20237D075)
- ML20237D078 + (ML20237D078)
- IR 05000361/1998008 + (ML20237D079)
- IR 05000321/1987029 + (ML20237D080)
- 05000454/LER-1996-014, :on 960903,failure to Comply W/Design Basis Re Sf Storage Racks Was Noted.Caused by Deterioration as Result of Improper Matl Selection.Controlled SFP Boron Concentration & Silica Concentration + (ML20237D082)
- ML20237D083 + (ML20237D083)
- 05000458/LER-1987-009, :on 870602,low Pressure Core Spray Inoperable Due to Improper Transmitter Calibr.Caused by Nonincorporation of Head Correction.Trip Units Associated W/ Transmitters Adjusted + (ML20237D084)
- 05000336/LER-1998-005-01, Forwards LER 98-005-01 Re HELB Deficiencies for Piping Inside Containment on 980318.Commitments,encl + (ML20237D085)
- ML20237D086 + (ML20237D086)
- ML20237D088 + (ML20237D088)
- ML20237D089 + (ML20237D089)
- ML20237D090 + (ML20237D090)
- ML20237D091 + (ML20237D091)
- ML20237D093 + (ML20237D093)
- ML20237D094 + (ML20237D094)
- ML20237D096 + (ML20237D096)
- ML20237D097 + (ML20237D097)
- 05000302/LER-1987-029, :on 871118,determined That Monthly Surveillance for Liquid Process & Effluent Radiation Monitors Not Performed & Three Surveillances Exceeded by One Day.Caused by Personnel Error.Personnel Instructed + (ML20237D098)