- 05000219/LER-1985-005-02, :on 850210,during Routine Surveillance Testing, Isolation Condenser Pipe Break Sensors IB05A1,IB05B1,IB11A1, IB11B1 & IB11B2 Tripped at Values Greater than Tech Specs. Caused by Instrument Drift.Sensors Reset + (ML20214P141)
- ML20214P142 + (ML20214P142)
- ML20214P143 + (ML20214P143)
- ML20214P144 + (ML20214P144)
- IR 05000312/1987006 + (ML20214P148)
- 05000247/LER-1986-036, :on 861023,reactor Tripped Manually Following Automatic Trip of Main Boiler Feed Pump on High Discharge Pressure Due to Excess Flow.Caused by Problems W/Main Feedwater Discharge Valves + (ML20214P151)
- ML20214P154 + (ML20214P154)
- ML20214P155 + (ML20214P155)
- IR 05000454/1986036 + (ML20214P159)
- ML20214P160 + (ML20214P160)
- IR 05000348/1986022 + (ML20214P161)
- ML20214P163 + (ML20214P163)
- 05000327/LER-1984-025-01, :on 840415,sampling of RCS for Boron Concentration Initiated,Causing Pressurizer Level Transmitter 1-LT-68-320 to Be Inoperable.Caused by Operator Error.Transmitter Moved + (ML20214P164)
- 0CAN118601, Forwards Revised Version of Integrated Implementation Plan for Tasks in Response to NUREG-0737,Suppl 1.Progress on Crdr,Spds,Emergency Operating Procedures & Reg Guide 1.97 Mods Described.Next Update Scheduled for Apr 1987 + (ML20214P165)
- ML20214P167 + (ML20214P167)
- ML20214P168 + (ML20214P168)
- 05000302/LER-1986-013, :on 860815,following Control Complex Return Duct Radiation Monitor Failure,Operator Placed Control Room Ventilation Sys in Recirculation Mode Using Supply Fan. Caused by Operator Error + (ML20214P169)
- ML20214P178 + (ML20214P178)
- ML20214P179 + (ML20214P179)
- ML20214P180 + (ML20214P180)
- ML20214P182 + (ML20214P182)
- PNO-III-86-094, on 860910,federal Grand Jury in State of Mi Western District Indicted Util & Jg Del Percio W/Violations of NRC Fire Protection Requirements Occurring from Mar 1981 - Apr 1982 + (ML20214P183)
- ML20214P187 + (ML20214P187)
- 05000416/LER-1986-040, :on 861027,determined That Two Weekly Surveillances of Breaker Alignment Not Performed in Required Tech Spec Time Interval.Caused by Nonlicensed Operator Oversight.Procedures Now Hand Carried + (ML20214P189)
- ML20214P190 + (ML20214P190)
- ML20214P191 + (ML20214P191)
- PNO-III-86-096, on 860911,bomb Threat Received at Telephone Switchboard,Stating That Bomb Placed in Training Ctr.Ctr Evacuated & Facility Searched.No Bomb Found.Nrc Info Assessment Team Notified + (ML20214P194)
- RBG-24816, Forwards Suppl 1 to Startup Test Rept, Covering Period Through 861031.Info Submitted Per Tech Specs 6.9.1.2 & 6.9.1.3 & Reg Guides 1.16 & 1.68 + (ML20214P195)
- ML20214P197 + (ML20214P197)
- ML20214P199 + (ML20214P199)
- ML20214P200 + (ML20214P200)
- ST-HL-AE-2213, Forwards Proprietary & Nonproprietary Addl Info in Support of Elimination of Postulated Pipe Ruptures in Accumulator Lines of South Texas Projects Units 1 & 2 (WCAP-11383/11351) (10-Inch & 8-Inch RHR Piping Attached to Accumulator Line + (ML20214P204)
- PNO-II-86-087, on 861107,employee Received Calculated Exposure of 75 Rems to One Hand,Exceeding 10CFR20,18.75 Rems Limit.Cause of Contamination Undetermined.Region II Radiation Specialist Dispatched for Followup + (ML20214P205)
- ML20214P206 + (ML20214P206)
- ML20214P208 + (ML20214P208)
- ML20214P209 + (ML20214P209)
- ML20214P210 + (ML20214P210)