- ML20151N314 + (ML20151N314)
- B12875, Forwards Temporary Change to Physical Security Plan Re Protected Area Boundary.Rev Withheld (Ref 10CFR72.790(a)) + (ML20151N315)
- ML20151N316 + (ML20151N316)
- 05000344/LER-1988-021, :on 880703,two Component Cooling Water Valves Returned to Svc After Maint W/O Being Demonstrated Operable Per Tech Specs.Caused by Personnel Error.Stroke Time Valve Testing Performed to Demonstrate Operability + (ML20151N337)
- IR 05000263/1988008 + (ML20151N340)
- ML20151N341 + (ML20151N341)
- ML20151N344 + (ML20151N344)
- ML20151N351 + (ML20151N351)
- ML20151N357 + (ML20151N357)
- ML20151N359 + (ML20151N359)
- ML20151N362 + (ML20151N362)
- ML20151N367 + (ML20151N367)
- ML20151N377 + (ML20151N377)
- 05000416/LER-1988-011, :on 880317,inadvertent RHR Pump Start Occurred During Monthly Functional Test of RHR Pump B Start Time Delay.Caused by Electrician Error.Appropriate Personnel Will Be Retrained & Procedures Will Be Enhanced + (ML20151N379)
- ML20151N380 + (ML20151N380)
- ML20151N384 + (ML20151N384)
- ML20151N389 + (ML20151N389)
- ML20151N392 + (ML20151N392)
- IR 05000458/1985072 + (ML20151N394)
- B12956, Informs NRC of Interim Compensatory Measures That Will Be Taken While Shutdown Cooling Sys (SDC) Inoperable.Posting Fire Watch in Switchgear Room Provides Added Assurance of Availability of Components Needed to Achieve Cold Shutdown + (ML20151N397)
- ML20151N398 + (ML20151N398)
- A071168, Clarifies Util Containing Interpretation That 10CFR50.59 Would Govern Whether or Not Prior NRC Approval Required to Use Temporary Spent Fuel Racks for long-term Spent Fuel Storage + (ML20151N404)
- ML20151N406 + (ML20151N406)
- ML20151N408 + (ML20151N408)
- ML20151N410 + (ML20151N410)
- ML20151N412 + (ML20151N412)
- ML20151N417 + (ML20151N417)
- ML20151N419 + (ML20151N419)
- NRC-88-3360, Forwards Amend 2 to Proprietary & Nonproprietary RESAR-SP/90 Pda Module 11, Radiation Protection & RESAR-SP/90 Pda Module 12, Waste Mgt. Proprietary Repts Withheld (Ref 10CFR2.790) + (ML20151N421)
- ML20151N424 + (ML20151N424)
- ML20151N428 + (ML20151N428)
- ML20151N429 + (ML20151N429)
- ML20151N432 + (ML20151N432)
- ML20151N442 + (ML20151N442)
- 05000327/LER-1981-023-03, /03L-1:on 810303,four Undersized Pipe Sleeves Associated W/Seal Injection Water Lines to Reactor Coolant Pumps Identified.Caused by Incorrect Installation.Workplan 9073 Issued to Reshape Subj Piping Sleeves + (ML20151N445)
- ML20151N446 + (ML20151N446)
- ML20151N448 + (ML20151N448)
- ML20151N453 + (ML20151N453)
- ST-HL-AE-1556, Second Interim Deficiency Rept Re Control of Bechtel Std Computer Programs.Initially Reported on 850905.Bechtel Conducted QA Mgt Audit of Western Power Div.Error Notices Under Evaluation.Next Rept Will Be Submitted by 860327 + (ML20151N454)
- IR 05000457/1988012 + (ML20151N459)
- ML20151N462 + (ML20151N462)
- ML20151N465 + (ML20151N465)
- ML20151N470 + (ML20151N470)
- ML20151N471 + (ML20151N471)
- ML20151N474 + (ML20151N474)
- ML20151N476 + (ML20151N476)
- ML20151N478 + (ML20151N478)
- 05000289/LER-1985-004-02, :on 851126,21 & 23,core Borings Identified as Fire Penetrations Performed W/O Installation of Fire Penetration Seals or Establishment of Fire Watch.Caused by Personnel Error + (ML20151N479)
- ML20151N481 + (ML20151N481)
- ML20151N488 + (ML20151N488)
- ML20151N490 + (ML20151N490)