- ML20082E658 + (ML20082E658)
- 05000282/LER-1994-009, :on 941029,design Deficiency of Containment Integrity & Containment Isolation Discovered.Caused by Apparent Oversight During Original Plant Design.Procedures Revised to Cover Deficiency + (ML20082E663)
- 05000260/LER-1983-068-03, /03L-0:on 831021,during Normal Operation,Rhr Loop II Flow Instrumentation Pegged Upscale.Caused by Short in GE Type 531 Recorder Which Drove FR-74-64 & FI-74-64 Upscale Causing Fuse to Blow.Fuse Replaced + (ML20082E665)
- ML20082E669 + (ML20082E669)
- ML20082E670 + (ML20082E670)
- 05000440/LER-1995-001, :on 950307,identified Condition Which Could Allow Primary Containment Leakage Rates to Exceed TS Limit. Caused by Inadequate Design of Airlock Lcs.Initiation of Permanent Design Change + (ML20082E673)
- ML20082E677 + (ML20082E677)
- ML20082E678 + (ML20082E678)
- ML20082E679 + (ML20082E679)
- ML20082E681 + (ML20082E681)
- ML20082E683 + (ML20082E683)
- 05000440/LER-1995-002, :on 950310,unplanned Automatic Actuation of Backup Drywell Purge Sys Isolation Valves Occurred.Caused by Personnel Error.Reactor Operator & Entire CR Staff Counseled Re Event + (ML20082E685)
- ML20082E691 + (ML20082E691)
- 05000362/LER-1983-093-03, /03L-0:on 831017,core Protection Calculator Channel C & ex-core Linear Power Level Channel C Declared Inoperable.Caused by Failed Linear Amplifier Card.Card Replaced + (ML20082E692)
- ML20082E695 + (ML20082E695)
- ML20082E696 + (ML20082E696)
- ML20082E703 + (ML20082E703)
- ML20082E706 + (ML20082E706)
- L-95-009, Monthly Operating Repts for Mar 1995 for Point Beach Nuclear Plant,Units 1 & 2 + (ML20082E707)
- 05000316/LER-1983-101-03, /03L-0:on 831018,turbine Driven Auxiliary Feed Pump Trip & Throttle Valve Failed to Trip When Signal Initiated from Control Room.Caused by Rusted Stem Threads. Threads Cleaned & Lubricated.Valve Tested Satisfactorily + (ML20082E709)
- ML20082E711 + (ML20082E711)
- ML20082E714 + (ML20082E714)
- ML20082E716 + (ML20082E716)
- ML20082E718 + (ML20082E718)
- 05000316/LER-1983-102-03, /03L-0:on 831029,NESW from Lower Containment Ventilation Unit 3 Isolation Valve Failed to Meet Required Criterion of Closing within 10 S.Caused by Worn Insert in Solenoid Valve Mfg by Asco.Valve Rebuilt + (ML20082E729)
- ML20082E738 + (ML20082E738)
- 05000361/LER-1983-129-03, /03L-0:on 831016,calculations Indicated That DNBR Margin Not within Allowable Limits.Cause & Corrective Action to Prevent Recurrence Under Review.Dnbr Margin Verified within 1 H by Restoring Core Limit + (ML20082E740)
- ML20082E742 + (ML20082E742)
- ML20082E743 + (ML20082E743)
- ML20082E747 + (ML20082E747)
- ML20082E749 + (ML20082E749)
- 05000259/LER-1983-060-03, /03L-0:on 831018,containment Atmosphere Dilution Tank a Nitrogen Level Decreased to Below 74% Full.Caused by Leaks in Velan Valves.Vendor Requested to Replenish Lost Nitrogen Vol on 831017 + (ML20082E750)
- ML20082E754 + (ML20082E754)
- ML20082E758 + (ML20082E758)
- 05000289/LER-1983-037-03, /03L-0:on 831013,during Degassification of RCS, Waste Gas Sys Monitor Became Inoperable.Vent Header Pressure Exceeded Max Analyzer Discharge Pressure.Header Pressure Reduced + (ML20082E764)
- TXX-4079, Informs That Static & Dynamic Load Testing Successfully Completed on Containment Polar Crane.Testing Ensures Safety of Vital Equipment in Containment While Satisfying Guidance of NUREG-0554 & Fulfills FSAR Commitments + (ML20082E767)
- ML20082E770 + (ML20082E770)
- ML20082E773 + (ML20082E773)
- ML20082E777 + (ML20082E777)
- ML20082E780 + (ML20082E780)
- ML20082E784 + (ML20082E784)
- ML20082E789 + (ML20082E789)
- ML20082E798 + (ML20082E798)
- ML20082E799 + (ML20082E799)
- ST-HL-AE-1026, First Interim Deficiency Rept Re Corrosion in Safety Injection Sys Weld.Corrective Actions Will Be Established Upon Completion of Investigation to Determine Extent of Corrosion.Next Rept by 840420 + (ML20082E807)
- 05000315/LER-1983-106-03, /03L-0:on 830805,surveillance Testing of Steam Generator Snubber 25.12620.007-7 Revealed Inability to Lockup During Normal & Restrained Operating Mode Testing. Caused by Worn Piston Seals.Seals & O-rings Replaced + (ML20082E810)
- ML20082E811 + (ML20082E811)
- ML20082E813 + (ML20082E813)
- ML20082E814 + (ML20082E814)
- ML20082E826 + (ML20082E826)
- 05000278/LER-1983-016-03, /03L-0:on 831017,during Startup,Moisture Sensor in Moisture Monitoring Sys Failed.Caused by Defective Techmark Ltd Sensor.Sensor Will Be Replaced + (ML20082E828)